Population-Based Pediatric Reference Intervals in General Clinical Chemistry: A Swedish Survey.
Ridefelt, Peter
2015-01-01
Very few high quality studies on pediatric reference intervals for general clinical chemistry and hematology analytes have been performed. Three recent prospective community-based projects utilising blood samples from healthy children in Sweden, Denmark and Canada have substantially improved the situation. The Swedish survey included 701 healthy children. Reference intervals for general clinical chemistry and hematology were defined.
Reference Intervals of Common Clinical Chemistry Analytes for Adults in Hong Kong.
Lo, Y C; Armbruster, David A
2012-04-01
Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples. Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing. The samples were tested for twenty-five routine analytes on the Abbott ARCHITECT clinical chemistry system. Results were analyzed using the Rhoads EP evaluator software program, which is based on the CLSI/IFCC C28-A guideline, and defines the reference interval as the 95% central range. Method specific reference intervals were established for twenty-five common clinical chemistry analytes for a Chinese ethnic population. The intervals were defined for each gender separately and for genders combined. Gender specific or combined gender intervals were adapted as appropriate for each analyte. A large number of healthy, apparently normal blood donors from a local ethnic population were tested to provide current reference intervals for a new clinical chemistry system. Intervals were determined following an accepted international guideline. Laboratories using the same or similar methodologies may adapt these intervals if deemed validated and deemed suitable for their patient population. Laboratories using different methodologies may be able to successfully adapt the intervals for their facilities using the reference interval transference technique based on a method comparison study.
Estimating reliable paediatric reference intervals in clinical chemistry and haematology.
Ridefelt, Peter; Hellberg, Dan; Aldrimer, Mattias; Gustafsson, Jan
2014-01-01
Very few high-quality studies on paediatric reference intervals for general clinical chemistry and haematology analytes have been performed. Three recent prospective community-based projects utilising blood samples from healthy children in Sweden, Denmark and Canada have substantially improved the situation. The present review summarises current reference interval studies for common clinical chemistry and haematology analyses. ©2013 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Mekonnen, Zewdie; Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob
2017-01-01
Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer's instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li'an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-03-01
A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.
Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China
Xia, Liangyu; Chen, Ming; Liu, Min; Tao, Zhihua; Li, Shijun; Wang, Liang; Cheng, Xinqi; Qin, Xuzhen; Han, Jianhua; Li, Pengchang; Hou, Li’an; Yu, Songlin; Ichihara, Kiyoshi; Qiu, Ling
2016-01-01
Abstract A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box–Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China. PMID:26945390
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children
Lee, Hye Ryun; Roh, Eun Youn; Chang, Ju Young
2016-01-01
Background Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. Methods A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. Results As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. Conclusions We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age. PMID:27374715
Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Roh, Eun Youn; Chang, Ju Young
2016-09-01
Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Bias Assessment of General Chemistry Analytes using Commutable Samples.
Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter
2014-11-01
Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.
Amuamuta, Asmare; Mulu, Wondemagegn; Yimer, Mulat; Zenebe, Yohannes; Adem, Yesuf; Abera, Bayeh; Gebeyehu, Wondemu; Gebregziabher, Yakob
2017-01-01
Background Reference interval is crucial for disease screening, diagnosis, monitoring, progression and treatment efficacy. Due to lack of locally derived reference values for the parameters, clinicians use reference intervals derived from western population. But, studies conducted in different African countries have indicated differences between locally and western derived reference values. Different studies also indicated considerable variation in clinical chemistry reference intervals by several variables such as age, sex, geographical location, environment, lifestyle and genetic variation. Objective This study aimed to determine the reference intervals of common clinical chemistry parameters of the community of Gojjam Zones, Northwest Ethiopia. Method Population based cross-sectional study was conducted from November 2015 to December 2016 in healthy adult populations of Gojjam zone. Data such as, medical history, physical examination and socio-demographic data were collected. In addition, laboratory investigations were undertaken to screen the population. Clinical chemistry parameters were measured using Mindray BS 200 clinical chemistry autoanalyzer as per the manufacturer’s instructions. Descriptive statistics was used to calculate mean, median and 95th percentiles. Independent sample T-test and one way ANOVA were used to see association between variables. Results After careful screening of a total of 799 apparently healthy adults who were consented for this study, complete data from 446 (224 females and 222 males) were included for the analysis. The mean age of both the study participants was 28.8 years. Males had high (P<0.05) mean and 2.5th-97.5th percentile ranges of ALT, AST, ALP, creatinine and direct bilirubin. The reference intervals of amylase, LDH, total protein and total bilirubin were not significantly different between the two sex groups (P>0.05). Mean, median, 95% percentile values of AST, ALP, amylase, LDH, creatinine, total protein, total bilirubin, and direct bilirubin across all age groups of participants were similar (P>0.05). But, there was a significant difference in the value of ALT (P<0.05). The reference intervals of ALT, total protein and creatinine were significantly (P<0.05) high in people having monthly income >1500 ETB compared to those with low monthly income. Significant (P<0.05) higher values of the ALT, ALP and total protein were observed in people living in high land compared to low land residences. Conclusion The study showed that some of the common clinical chemistry parameters reference intervals of healthy adults in Gojjam zones were higher than the reference intervals generated from developed countries. Therefore, strict adherence to the reference values generated in developed countries could lead to inappropriate diagnosis and treatment of patients. There was also variation of reference interval values based on climate, gender, age, monthly income and geographical locations. Therefore, further study is required to establish reference intervals for Ethiopian population. PMID:28886191
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.
Hematologic and serum chemistry reference intervals for free-ranging lions (Panthera leo).
Maas, Miriam; Keet, Dewald F; Nielen, Mirjam
2013-08-01
Hematologic and serum chemistry values are used by veterinarians and wildlife researchers to assess health status and to identify abnormally high or low levels of a particular blood parameter in a target species. For free-ranging lions (Panthera leo) information about these values is scarce. In this study 7 hematologic and 11 serum biochemistry values were evaluated from 485 lions from the Kruger National Park, South Africa. Significant differences between sexes and sub-adult (≤ 36 months) and adult (>36 months) lions were found for most of the blood parameters and separate reference intervals were made for those values. The obtained reference intervals include the means of the various blood parameter values measured in captive lions, except for alkaline phosphatase in the subadult group. These reference intervals can be utilized for free-ranging lions, and may likely also be used as reference intervals for captive lions. Copyright © 2013 Elsevier Ltd. All rights reserved.
Reference values of thirty-one frequently used laboratory markers for 75-year-old males and females
Ryden, Ingvar; Lind, Lars
2012-01-01
Background We have previously reported reference values for common clinical chemistry tests in healthy 70-year-old males and females. We have now repeated this study 5 years later to establish reference values also at the age of 75. It is important to have adequate reference values for elderly patients as biological markers may change over time, and adequate reference values are essential for correct clinical decisions. Methods We have investigated 31 frequently used laboratory markers in 75-year-old males (n = 354) and females (n = 373) without diabetes. The 2.5 and 97.5 percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry. Results Reference values are reported for 75-year-old males and females for 31 frequently used laboratory markers. Conclusion There were minor differences between reference intervals calculated with and without individuals with cardiovascular diseases. Several of the reference intervals differed from Scandinavian reference intervals based on younger individuals (Nordic Reference Interval Project). PMID:22300333
Matsche, Mark A; Arnold, Jill; Jenkins, Erin; Townsend, Howard; Rosemary, Kevin
2014-09-01
The imperiled status of Atlantic sturgeon (Acipenser oxyrinchus oxyrinchus), a large, long-lived, anadromous fish found along the Atlantic coast of North America, has prompted efforts at captive propagation for research and stock enhancement. The purpose of this study was to establish hematology and plasma chemistry reference intervals of captive Atlantic sturgeon maintained under different culture conditions. Blood specimens were collected from a total of 119 fish at 3 hatcheries: Lamar, PA (n = 36, ages 10-14 years); Chalk Point, MD (n = 40, siblings of Lamar); and Horn Point, Cambridge, MD (n = 43, mixed population from Chesapeake Bay). Reference intervals (using robust techniques), median, mean, and standard deviations were determined for WBC, RBC, thrombocytes, PCV, HGB, MCV, MCH, MCHC, and absolute counts for lymphocytes (L), neutrophils (N), monocytes, and eosinophils. Chemistry analytes included concentrations of total proteins, albumin, glucose, urea, calcium, phosphate, sodium, potassium, chloride, and globulins, AST, CK, and LDH activities, and osmolality. Mean concentrations of total proteins, albumin, and glucose were at or below the analytic range. Statistical comparisons showed significant differences among hatcheries for each remaining plasma chemistry analyte and for PCV, RBC, MCHC, MCH, eosinophil and monocyte counts, and N:L ratio throughout all 3 groups. Therefore, reference intervals were calculated separately for each population. Reference intervals for fish maintained under differing conditions should be established per population. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Ridefelt, Peter; Hilsted, Linda; Juul, Anders; Hellberg, Dan; Rustad, Pål
2018-05-28
Reference intervals are crucial tools aiding clinicians when making medical decisions. However, for children such values often are lacking or incomplete. The present study combines data from separate pediatric reference interval studies of Denmark and Sweden in order to increase sample size and to include also pre-school children who were lacking in the Danish study. Results from two separate studies including 1988 healthy children and adolescents aged 6 months to 18 years of age were merged and recalculated. Eighteen general clinical chemistry components were measured on Abbott and Roche platforms. To facilitate commutability, the NFKK Reference Serum X was used. Age- and gender-specific pediatric reference intervals were defined by calculating 2.5 and 97.5 percentiles. The data generated are primarily applicable to a Nordic population, but could be used by any laboratory if validated for the local patient population.
Indirect methods for reference interval determination - review and recommendations.
Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim
2018-04-19
Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.
Estimating clinical chemistry reference values based on an existing data set of unselected animals.
Dimauro, Corrado; Bonelli, Piero; Nicolussi, Paola; Rassu, Salvatore P G; Cappio-Borlino, Aldo; Pulina, Giuseppe
2008-11-01
In an attempt to standardise the determination of biological reference values, the International Federation of Clinical Chemistry (IFCC) has published a series of recommendations on developing reference intervals. The IFCC recommends the use of an a priori sampling of at least 120 healthy individuals. However, such a high number of samples and laboratory analysis is expensive, time-consuming and not always feasible, especially in veterinary medicine. In this paper, an alternative (a posteriori) method is described and is used to determine reference intervals for biochemical parameters of farm animals using an existing laboratory data set. The method used was based on the detection and removal of outliers to obtain a large sample of animals likely to be healthy from the existing data set. This allowed the estimation of reliable reference intervals for biochemical parameters in Sarda dairy sheep. This method may also be useful for the determination of reference intervals for different species, ages and gender.
Hematology and plasma chemistry reference intervals for cultured tilapia (Oreochromis hybrid).
Hrubec, Terry C.; Cardinale, Jenifer L.; Smith, Stephen A.
2000-01-01
Tilapia are a commonly aquacultured fish yet little is known about their normal physiology and response to disease. In this study we determined the results of complete hematologic (n=40) and plasma biochemical profiles (n=63) in production tilapia (Oreochromis hybrids). The fish were raised in recirculating systems with a high stocking density (120 g/L), and were in the middle of a 15-month production cycle. Blood was analyzed using standard techniques, and reference intervals were determined using nonparametric methods. Non-production tilapia (n=15) from low-density tanks (4 g/L) also were sampled; the clinical chemistry results were compared to reference intervals from the fish raised in high-density tanks. Differences were noted in plasma protein, calcium and phosphorus concentrations, such that reference intervals for high-density production tilapia were not applicable to fish raised under different environmental and management conditions.
Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow
2016-04-01
The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to <19 years of age were recruited from the community. Serum samples were collected for measurement of 29 biomarkers on the Beckman Coulter Immunoassay Systems. Statistically relevant age and/or gender-based partitions were determined, outliers removed, and reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.
Higgins, Victoria; Truong, Dorothy; Woroch, Amy; Chan, Man Khun; Tahmasebi, Houman; Adeli, Khosrow
2018-03-01
Evidence-based reference intervals (RIs) are essential to accurately interpret pediatric laboratory test results. To fill gaps in pediatric RIs, the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) project developed an age- and sex-specific pediatric RI database based on healthy pediatric subjects. Originally established for Abbott ARCHITECT assays, CALIPER RIs were transferred to assays on Beckman, Roche, Siemens, and Ortho analytical platforms. This study provides transferred reference intervals for 29 biochemical assays for the Ortho VITROS 5600 Chemistry System (Ortho). Based on Clinical Laboratory Standards Institute (CLSI) guidelines, a method comparison analysis was performed by measuring approximately 200 patient serum samples using Abbott and Ortho assays. The equation of the line of best fit was calculated and the appropriateness of the linear model was assessed. This equation was used to transfer RIs from Abbott to Ortho assays. Transferred RIs were verified using 84 healthy pediatric serum samples from the CALIPER cohort. RIs for most chemistry analytes successfully transferred from Abbott to Ortho assays. Calcium and CO 2 did not meet statistical criteria for transference (r 2 <0.70). Of the 32 transferred reference intervals, 29 successfully verified with approximately 90% of results from reference samples falling within transferred confidence limits. Transferred RIs for total bilirubin, magnesium, and LDH did not meet verification criteria and are not reported. This study broadens the utility of the CALIPER pediatric RI database to laboratories using Ortho VITROS 5600 biochemical assays. Clinical laboratories should verify CALIPER reference intervals for their specific analytical platform and local population as recommended by CLSI. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Estey, Mathew P; Cohen, Ashley H; Colantonio, David A; Chan, Man Khun; Marvasti, Tina Binesh; Randell, Edward; Delvin, Edgard; Cousineau, Jocelyne; Grey, Vijaylaxmi; Greenway, Donald; Meng, Qing H; Jung, Benjamin; Bhuiyan, Jalaluddin; Seccombe, David; Adeli, Khosrow
2013-09-01
The CALIPER program recently established a comprehensive database of age- and sex-stratified pediatric reference intervals for 40 biochemical markers. However, this database was only directly applicable for Abbott ARCHITECT assays. We therefore sought to expand the scope of this database to biochemical assays from other major manufacturers, allowing for a much wider application of the CALIPER database. Based on CLSI C28-A3 and EP9-A2 guidelines, CALIPER reference intervals were transferred (using specific statistical criteria) to assays performed on four other commonly used clinical chemistry platforms including Beckman Coulter DxC800, Ortho Vitros 5600, Roche Cobas 6000, and Siemens Vista 1500. The resulting reference intervals were subjected to a thorough validation using 100 reference specimens (healthy community children and adolescents) from the CALIPER bio-bank, and all testing centers participated in an external quality assessment (EQA) evaluation. In general, the transferred pediatric reference intervals were similar to those established in our previous study. However, assay-specific differences in reference limits were observed for many analytes, and in some instances were considerable. The results of the EQA evaluation generally mimicked the similarities and differences in reference limits among the five manufacturers' assays. In addition, the majority of transferred reference intervals were validated through the analysis of CALIPER reference samples. This study greatly extends the utility of the CALIPER reference interval database which is now directly applicable for assays performed on five major analytical platforms in clinical use, and should permit the worldwide application of CALIPER pediatric reference intervals. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Chichester, Lee; Gee, Melaney K; Jorgensen, Matthew J; Kaplan, Jay R
2015-07-01
Clinical decisions and experimental analyses often involve the assessment of hematology and clinical chemistry. Using clinical pathology to assess the health status of NHP in breeding colonies or data from studies than involve pregnancy can often be complicated by pregnancy status. This study had 2 objectives regarding the hematology and clinical chemistry of African green monkeys (AGM, Chlorocebus aethiops sabaeus): 1) to compare pregnant or recently postpartum animals with nonpregnant, nonlactating animals and 2) to create age- and sex-specific reference intervals. Subjects in this study were 491 AGM from the Vervet Research Colony of the Wake Forest University Primate Center. Results indicated that changes in BUN, serum total protein, albumin, ALP, GGT, calcium, phosphorus, sodium, potassium, cholesterol, total CO2, globulins, lipase, amylase, WBC, neutrophils, lymphocytes, platelets, RBC, Hgb, and Hct occur during pregnancy and the postpartum period. Age- and sex-specific reference intervals consistent with guidelines from the American Society for Veterinary Clinical Pathology were established and further expand the understanding of how to define health in AGM on the basis of clinical pathology. The combination of understanding the changes that occur in pregnancy and postpartum and expansive reference intervals will help guide clinical and experimental decisions.
Iversen, B S; Sabbioni, E; Fortaner, S; Pietra, R; Nicolotti, A
2003-01-20
Statistical data treatment is a key point in the assessment of trace element reference values being the conclusive stage of a comprehensive and organized evaluation process of metal concentration in human body fluids. The EURO TERVIHT project (Trace Elements Reference Values in Human Tissues) was started for evaluating, checking and suggesting harmonized procedures for the establishment of trace element reference intervals in body fluids and tissues. Unfortunately, different statistical approaches are being used in this research field making data comparison difficult and in some cases impossible. Although international organizations such as International Federation of Clinical Chemistry (IFCC) or International Union of Pure and Applied Chemistry (IUPAC) have issued recommended guidelines for reference values assessment, including the statistical data treatment, a unique format and a standardized data layout is still missing. The aim of the present study is to present a software (BioReVa) running under Microsoft Windows platform suitable for calculating the reference intervals of trace elements in body matrices. The main scope for creating an ease-of-use application was to control the data distribution, to establish the reference intervals according to the accepted recommendation, on the base of the simple statistic, to get a standard presentation of experimental data and to have an application to which further need could be integrated in future. BioReVa calculates the IFCC reference intervals as well as the coverage intervals recommended by IUPAC as a supplement to the IFCC intervals. Examples of reference values and reference intervals calculated with BioReVa software concern Pb and Se in blood; Cd, In and Cr in urine, Hg and Mo in hair of different general European populations. University of Michigan
Ridefelt, Peter; Aldrimer, Mattias; Rödöö, Per-Olof; Niklasson, Frank; Jansson, Leif; Gustafsson, Jan; Hellberg, Dan
2012-02-29
Reference intervals are crucial decision-making tools aiding clinicians in differentiating between healthy and diseased populations. However, for children such values often are lacking or incomplete. Blood samples were obtained from 692 healthy children, aged 6 months to 18 years, recruited in daycare centers and schools. Twelve common general clinical chemistry analytes were measured on the Abbott Architect ci8200 platform; sodium, potassium, chloride, calcium, albumin-adjusted calcium, phosphate, magnesium, creatinine (Jaffe and enzymatic), cystatin C, urea and uric acid. Age- and gender specific pediatric reference intervals were defined by calculating the 2.5th and 97.5th percentiles. The data generated is primarily applicable to a Caucasian population when using the Abbott Architect platform, but could be used by any laboratory if validated for the local patient population.
Whiting, S D; Guinea, M L; Fomiatti, K; Flint, M; Limpus, C J
2014-06-14
In recent years, the use of blood chemistry as a diagnostic tool for sea turtles has been demonstrated, but much of its effectiveness relies on reference intervals. The first comprehensive blood chemistry values for healthy wild hawksbill (Eretmochelys imbricata) sea turtles are presented. Nineteen blood chemistry analytes and packed cell volume were analysed for 40 clinically healthy juvenile hawksbill sea turtles captured from a rocky reef habitat in northern Australia. We used four statistical approaches to calculate reference intervals and to investigate their use with non-normal distributions and small sample sizes, and to compare upper and lower limits between methods. Eleven analytes were correlated with curved carapace length indicating that body size should be considered when designing future studies and interpreting analyte values. British Veterinary Association.
Serum chemistry of free-ranging white whales (Delphinapterus leucas) in Svalbard.
Tryland, Morten; Thoresen, Stein Istre; Kovacs, Kit M; Lydersen, Christian
2006-06-01
Abnormal physiological conditions and diseases can change the concentrations of enzymes, metabolites, and minerals in the body. Serum chemistry information may thus be indicative of a specific disease; interpretation of such information requires knowledge of serum chemistry reference intervals from a seemingly healthy population of the species. The aim of this study was to obtain serum chemistry reference intervals for a population of white whales. Blood samples were collected from 21 free-ranging white whales (beluga; Delphinapterus leucas). The whales were live-captured in nets during 1996-2001 in Storfjorden, Van Mijenfjorden, and Van Keulenfjorden (Svalbard, Norway). While the whales were briefly physically restrained, blood was collected from the caudal vein into vacuum tubes without anticoagulant. The blood was left to clot for 4-6 hours before serum was obtained by centrifugation. The serum samples were then kept at -20 degrees C until analysis. Enzymes (aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase [ALP], creatine kinase, lactate dehydrogenase [LDH], amylase, lipase), metabolites (urea, creatinine, bilirubin, cholesterol, triglycerides, nonesterified fatty acids, glucose), and minerals (calcium, phosphate, magnesium, sodium, potassium, chloride) were analyzed in an Advia 1650 System (Bayer, Tarrytown, NY, USA). Cortisol was analyzed in an Immulite One system (Diagnostic Products Corporation, Los Angeles, CA, USA). The major blood proteins (albumin and globulins) were separated by gel electrophoresis in a Beckman Paragon electrophoresis system (Beckman Coulter, Inc., Fullerton, CA, USA). Serum values for all analytes were reported as median and range, and reference intervals were calculated as 10-90th percentiles. Activities of ALP and LDH and cortisol concentration were higher, and protein and bilirubin concentrations were lower compared with those previously reported for white whales from Canada; remaining results were strikingly similar in these 2 white whale populations. These data provide valuable serum chemistry reference intervals for future health assessments of white whales in Svalbard and other white whale populations, as well as captive individuals.
Tamimi, Waleed; Albanyan, Esam; Altwaijri, Yasmin; Tamim, Hani; Alhussein, Fahad
2012-04-01
Reference intervals for pubertal characteristics are influenced by genetic, geographic, dietary and socioeconomic factors. Therefore, the aim of this study was to establish age-specific reference intervals of glucose and lipid levels among local school children. This was cross-sectional study, conducted among Saudi school children. Fasting blood samples were collected from 2149 children, 1138 (53%) boys and 1011 (47%) girls, aged 6 to 18 years old. Samples were analyzed on the Architect c8000 Chemistry System (Abbott Diagnostics, USA) for glucose, cholesterol, triglycerides, HDL and LDL. Reference intervals were established by nonparametric methods between the 2.5th and 97.5th percentiles. Significant differences were observed between boys and girls for cholesterol and triglycerides levels in all age groups (P < 0.02). Only at age 6-7 years and at adolescents, HDL and LDL levels were found to be significant (P < 0.001). No significant differences were seen in glucose levels except at age 12 to 13 years. Saudi children have comparable serum cholesterol levels than their Western counterparts. This may reflect changing dietary habits and increasing affluence in Saudi Arabia. Increased lipid screening is anticipated, and these reference intervals will aid in the early assessment of cardiovascular and diabetes risk in Saudi pediatric populations.
Tate, Jillian R; Sikaris, Ken A; Jones, Graham RD; Yen, Tina; Koerbin, Gus; Ryan, Julie; Reed, Maxine; Gill, Janice; Koumantakis, George; Hickman, Peter; Graham, Peter
2014-01-01
Scientific evidence supports the use of common reference intervals (RIs) for many general chemistry analytes, in particular those with sound calibration and traceability in place. Already the Nordic countries and United Kingdom have largely achieved harmonised RIs. Following a series of workshops organised by the Australasian Association of Clinical Biochemists (AACB) between 2012 and 2014 at which an evidence-based approach for determination of common intervals was developed, pathology organisations in Australia and New Zealand have reached a scientific consensus on what adult and paediatric intervals we should use across Australasia. The aim of this report is to describe the processes that the AACB and the Royal College of Pathologists of Australasia have taken towards recommending the implementation of a first panel of common RIs for use in Australasia. PMID:25678727
Hrubec, Terry C.; Smith, Stephen A.; Robertson, John L.
2001-01-01
Hybrid striped bass (Morone chrysops X Morone saxatilis ) are an important aquaculture species yet there are few diagnostic tools available to assess their health. Hematology and clinical chemistry analyses are not used extensively in fish medicine due to the lack of reference intervals for various fish species, and because factors such as age can affect blood values. There is little published information regarding age-related changes in blood values of juvenile fish. It is important to evaluate juvenile fish, as this is the time they are raised in aquaculture settings. Determining age-related changes in the blood values of fishes would further develop clinical pathology as a diagnostic tool, enhancing both fish medicine and the aquaculture industry. The results of standard hematology and clinical chemistry analysis were evaluated in juvenile hybrid striped bass at 4, 6, 9, 15, and 19 months of age. Values for PCV and RBC indices were significantly lower, and plasma protein concentration was significantly higher in younger fish. Total WBC and lymphocyte counts were significantly higher in fish at 6 and 9 months of age, while neutrophil and monocyte counts were higher at 6, 9, and 15 months. Eosinophil counts were significantly higher in 9-month-old fish. The majority of hematologic values fell within previously established reference intervals, indicating that only slight modification to the intervals is necessary for evaluating hematologic results of hybrid striped bass at different ages. The following analytes deviated sufficiently from adult reference intervals to warrant separate reference values: plasma protein concentration at 4 months, WBC and lymphocyte counts at 15 and 19 months, and thrombocyte-like-cells at 9 months of age. Values for most biochemical analytes were significantly different among age groups except for creatinine and potassium concentrations. Comparisons with reference intervals were not made for biochemical analytes, because established reference intervals were not available. Age-related changes in hematologic and biochemical values of striped bass were similar to those reported for rainbow trout and mammals.
Cho, Sun-Mi; Lee, Sang-Guk; Kim, Ho Seong; Kim, Jeong-Ho
2014-12-01
Defining pediatric reference intervals is one of the most difficult tasks for laboratory physicians. The continuously changing physiology of growing children makes their laboratory values moving targets. In addition, ethnic and behavioral differences might also cause variations. The aim of this study was to establish age- and sex-specific partitioned reference intervals for 13 serum biochemical analytes in Korean children. A total of 2474 patients, girls aged 2-14 years and boys aged 2-16 years, who underwent a short stature workup but were diagnosed as normal at the Pediatric Endocrinology Clinic of Severance Hospital (Seoul, Korea) between September 2010 and June 2012 were included in this study. The levels of serum calcium, inorganic phosphorus, blood urea nitrogen, creatinine, uric acid, glucose, total cholesterol, total protein, albumin, alkaline phosphatase, aspartic aminotransferase, alanine aminotransferase, and total bilirubin were measured using a Hitachi 7600 analyzer (Hitachi High-Technologies Corporation, Tokyo, Japan). Reference intervals were partitioned according to sex or age subgroups using the Harris and Boyd method. Most analytes except calcium and albumin required partitioning either by sex or age. Age-specific partitioned reference intervals for alkaline phosphatase, creatinine, and total bilirubin were established for both males and females after being partitioned by sex. Additional age-specific partitioning of aspartic aminotransferase in females and total protein and uric acid in males was also required. Inorganic phosphorus, total cholesterol, alanine aminotransferase, blood urea nitrogen, and glucose were partitioned only by sex. This study provided updated age- and sex-specific pediatric reference intervals for 13 basic serum chemistry analytes from a sufficient number of healthy children by using a modern analytical chemistry platform. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Reference values for 27 clinical chemistry tests in 70-year-old males and females.
Carlsson, Lena; Lind, Lars; Larsson, Anders
2010-01-01
Reference values are usually defined based on blood samples from healthy men or nonpregnant women in the age range of 20-50 years. These values are not optimal for elderly patients, as many biological markers change over time and adequate reference values are important for correct clinical decisions. To validate NORIP (Nordic Reference Interval Project) reference values in a 70-year-old population. We studied 27 frequently used laboratory tests. The 2.5th and 97.5th percentiles for these markers were calculated according to the recommendations of the International Federation of Clinical Chemistry on the statistical treatment of reference values. Reference values are reported for plasma alanine aminotransferase, albumin, alkaline phosphatase, pancreas amylase, apolipoprotein A1, apolipoprotein B, aspartate aminotransferase, bilirubin, calcium, chloride, cholesterol, creatinine, creatine kinase, C-reactive protein, glucose, gamma-glutamyltransferase, HDL-cholesterol, iron, lactate dehydrogenase, LDL-cholesterol, magnesium, phosphate, potassium, sodium, transferrin, triglycerides, urate and urea. Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% CI of a Scandinavian population (NORIP). 2009 S. Karger AG, Basel.
Ventrella, Domenico; Dondi, Francesco; Barone, Francesca; Serafini, Federica; Elmi, Alberto; Giunti, Massimo; Romagnoli, Noemi; Forni, Monica; Bacci, Maria L
2017-01-17
The similarities between swine and humans in physiological and genomic patterns, and the great correlation in size and anatomy, make pigs extremely useful in preclinical studies. New-born piglets can represent a model for congenital and genetic diseases in new-born children. It is known that piglets may have significant differences in clinicopathological results compared to adult pigs. Therefore, adult laboratory reference intervals cannot be applied to piglets. The aim of this study was to compare haematological and chemical variables in piglets of two ages and determinate age-related reference intervals for commercial hybrid young pigs. Blood samples were collected under general anaesthesia from 130 animals divided into five- (P5) and 30- (P30) day-old piglets. Only P30 animals were treated with parenteral iron after birth. Samples were analysed using automated haematology (ADVIA 2120) and chemistry analysers, and age-related reference intervals were calculated. Significant higher values of RBC, Hb and HCT were observed in P30 animals when compared to P5, with an opposite trend for MCV. These results were associated with a reduction of the RBC regeneration process and the thrombopoietic response. The TSAT and TIBC were significantly higher in P30 compared to P5; however, piglets remained iron deficient compared to adult reference intervals reported previously. In conclusion, this paper emphasises the high variability occurring in clinicopathological variables between new-born and 30-day-old pigs, and between piglets and adult pigs. This study provides valuable reference data for piglets at precise ages and could be used in the future as historical control improving the Reduction in animal experiments, as suggested by the 3Rs principle.
Clinical Chemistry Reference Intervals for C57BL/6J, C57BL/6N, and C3HeB/FeJ Mice (Mus musculus)
Otto, Gordon P; Rathkolb, Birgit; Oestereicher, Manuela A; Lengger, Christoph J; Moerth, Corinna; Micklich, Kateryna; Fuchs, Helmut; Gailus-Durner, Valérie; Wolf, Eckhard; de Angelis, Martin Hrabě
2016-01-01
Although various mouse inbred strains are widely used to investigate disease mechanisms and to establish new therapeutic strategies, sex-specific reference intervals for laboratory diagnostic analytes that are generated from large numbers of animals have been unavailable. In this retrospective study, we screened data from more than 12,000 mice phenotyped in the German Mouse Clinic from January 2006 through June 2014 and selected animals with the genetic background of C57BL/6J, C57BL/6N, or C3HeB/FeJ. In addition, we distinguished between the C57BL/6NTac substrain and C57BL/6N mice received from other vendors. The corresponding data sets of electrolytes (sodium, potassium, calcium, chloride, inorganic phosphate), lipids (cholesterol, triglyceride), and enzyme activities (ALT, AST, ALP, α-amylase) and urea, albumin, and total protein levels were analyzed. Significant effects of age and sex on these analytes were identified, and strain- or substrain- and sex-specific reference intervals for 90- to 135-d-old mice were calculated. In addition, we include an overview of the literature that reports clinical chemistry values for wild-type mice of different strains. Our results support researchers interpreting clinical chemistry values from various mouse mutants and corresponding wild-type controls based on the examined strains and substrains. PMID:27423143
Clinical Chemistry Reference Intervals for C57BL/6J, C57BL/6N, and C3HeB/FeJ Mice (Mus musculus).
Otto, Gordon P; Rathkolb, Birgit; Oestereicher, Manuela A; Lengger, Christoph J; Moerth, Corinna; Micklich, Kateryna; Fuchs, Helmut; Gailus-Durner, Valérie; Wolf, Eckhard; Hrabě de Angelis, Martin
2016-01-01
Although various mouse inbred strains are widely used to investigate disease mechanisms and to establish new therapeutic strategies, sex-specific reference intervals for laboratory diagnostic analytes that are generated from large numbers of animals have been unavailable. In this retrospective study, we screened data from more than 12,000 mice phenotyped in the German Mouse Clinic from January 2006 through June 2014 and selected animals with the genetic background of C57BL/6J, C57BL/6N, or C3HeB/FeJ. In addition, we distinguished between the C57BL/6NTac substrain and C57BL/6N mice received from other vendors. The corresponding data sets of electrolytes (sodium, potassium, calcium, chloride, inorganic phosphate), lipids (cholesterol, triglyceride), and enzyme activities (ALT, AST, ALP, α-amylase) and urea, albumin, and total protein levels were analyzed. Significant effects of age and sex on these analytes were identified, and strain- or substrain- and sex-specific reference intervals for 90- to 135-d-old mice were calculated. In addition, we include an overview of the literature that reports clinical chemistry values for wild-type mice of different strains. Our results support researchers interpreting clinical chemistry values from various mouse mutants and corresponding wild-type controls based on the examined strains and substrains.
Koerbin, G; Cavanaugh, J A; Potter, J M; Abhayaratna, W P; West, N P; Glasgow, N; Hawkins, C; Armbruster, D; Oakman, C; Hickman, P E
2015-02-01
Development of reference intervals is difficult, time consuming, expensive and beyond the scope of most laboratories. The Aussie Normals study is a direct a priori study to determine reference intervals in healthy Australian adults. All volunteers completed a health and lifestyle questionnaire and exclusion was based on conditions such as pregnancy, diabetes, renal or cardiovascular disease. Up to 91 biochemical analyses were undertaken on a variety of analytical platforms using serum samples collected from 1856 volunteers. We report on our findings for 40 of these analytes and two calculated parameters performed on the Abbott ARCHITECTci8200/ci16200 analysers. Not all samples were analysed for all assays due to volume requirements or assay/instrument availability. Results with elevated interference indices and those deemed unsuitable after clinical evaluation were removed from the database. Reference intervals were partitioned based on the method of Harris and Boyd into three scenarios, combined gender, males and females and age and gender. We have performed a detailed reference interval study on a healthy Australian population considering the effects of sex, age and body mass. These reference intervals may be adapted to other manufacturer's analytical methods using method transference.
Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.
Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon
2016-05-01
Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.
Hyltoft Petersen, Per; Lund, Flemming; Fraser, Callum G; Sandberg, Sverre; Sölétormos, György
2018-01-01
Background Many clinical decisions are based on comparison of patient results with reference intervals. Therefore, an estimation of the analytical performance specifications for the quality that would be required to allow sharing common reference intervals is needed. The International Federation of Clinical Chemistry (IFCC) recommended a minimum of 120 reference individuals to establish reference intervals. This number implies a certain level of quality, which could then be used for defining analytical performance specifications as the maximum combination of analytical bias and imprecision required for sharing common reference intervals, the aim of this investigation. Methods Two methods were investigated for defining the maximum combination of analytical bias and imprecision that would give the same quality of common reference intervals as the IFCC recommendation. Method 1 is based on a formula for the combination of analytical bias and imprecision and Method 2 is based on the Microsoft Excel formula NORMINV including the fractional probability of reference individuals outside each limit and the Gaussian variables of mean and standard deviation. The combinations of normalized bias and imprecision are illustrated for both methods. The formulae are identical for Gaussian and log-Gaussian distributions. Results Method 2 gives the correct results with a constant percentage of 4.4% for all combinations of bias and imprecision. Conclusion The Microsoft Excel formula NORMINV is useful for the estimation of analytical performance specifications for both Gaussian and log-Gaussian distributions of reference intervals.
Kristensen, Gunn B B; Rustad, Pål; Berg, Jens P; Aakre, Kristin M
2016-09-01
We undertook this study to evaluate method differences for 5 components analyzed by immunoassays, to explore whether the use of method-dependent reference intervals may compensate for method differences, and to investigate commutability of external quality assessment (EQA) materials. Twenty fresh native single serum samples, a fresh native serum pool, Nordic Federation of Clinical Chemistry Reference Serum X (serum X) (serum pool), and 2 EQA materials were sent to 38 laboratories for measurement of cobalamin, folate, ferritin, free T4, and thyroid-stimulating hormone (TSH) by 5 different measurement procedures [Roche Cobas (n = 15), Roche Modular (n = 4), Abbott Architect (n = 8), Beckman Coulter Unicel (n = 2), and Siemens ADVIA Centaur (n = 9)]. The target value for each component was calculated based on the mean of method means or measured by a reference measurement procedure (free T4). Quality specifications were based on biological variation. Local reference intervals were reported from all laboratories. Method differences that exceeded acceptable bias were found for all components except folate. Free T4 differences from the uncommonly used reference measurement procedure were large. Reference intervals differed between measurement procedures but also within 1 measurement procedure. The serum X material was commutable for all components and measurement procedures, whereas the EQA materials were noncommutable in 13 of 50 occasions (5 components, 5 methods, 2 EQA materials). The bias between the measurement procedures was unacceptably large in 4/5 tested components. Traceability to reference materials as claimed by the manufacturers did not lead to acceptable harmonization. Adjustment of reference intervals in accordance with method differences and use of commutable EQA samples are not implemented commonly. © 2016 American Association for Clinical Chemistry.
Gillard, Jonathan
2015-12-01
This article re-examines parametric methods for the calculation of time specific reference intervals where there is measurement error present in the time covariate. Previous published work has commonly been based on the standard ordinary least squares approach, weighted where appropriate. In fact, this is an incorrect method when there are measurement errors present, and in this article, we show that the use of this approach may, in certain cases, lead to referral patterns that may vary with different values of the covariate. Thus, it would not be the case that all patients are treated equally; some subjects would be more likely to be referred than others, hence violating the principle of equal treatment required by the International Federation for Clinical Chemistry. We show, by using measurement error models, that reference intervals are produced that satisfy the requirement for equal treatment for all subjects. © The Author(s) 2011.
Kelishadi, Roya; Marateb, Hamid Reza; Mansourian, Marjan; Ardalan, Gelayol; Heshmat, Ramin; Adeli, Khosrow
2016-08-01
This study aimed to determine for the first time the age- and gender-specific reference intervals for biomarkers of bone, metabolism, nutrition, and obesity in a nationally representative sample of the Iranian children and adolescents. We assessed the data of blood samples obtained from healthy Iranian children and adolescents, aged 7 to 19 years. The reference intervals of glucose, lipid profile, liver enzymes, zinc, copper, chromium, magnesium, and 25-hydroxy vitamin D [25(OH)D] were determined according to the Clinical & Laboratory Standards Institute C28-A3 guidelines. The reference intervals were partitioned using the Harris-Boyd method according to age and gender. The study population consisted of 4800 school students (50% boys, mean age of 13.8 years). Twelve chemistry analyses were partitioned by age and gender, displaying the range of results between the 2.5th to 97.5th percentiles. Significant differences existed only between boys and girls at 18 to 19 years of age for low density lipoprotein-cholesterol. 25(OH)D had the only reference interval that was similar to all age groups and both sexes. This study presented the first national database of reference intervals for a number of biochemical markers in Iranian children and adolescents. It is the first report of its kind from the Middle East and North Africa. The findings underscore the importance of providing reference intervals in different ethnicities and in various regions.
Borai, Anwar; Ichihara, Kiyoshi; Al Masaud, Abdulaziz; Tamimi, Waleed; Bahijri, Suhad; Armbuster, David; Bawazeer, Ali; Nawajha, Mustafa; Otaibi, Nawaf; Khalil, Haitham; Kawano, Reo; Kaddam, Ibrahim; Abdelaal, Mohamed
2016-05-01
This study is a part of the IFCC-global study to derive reference intervals (RIs) for 28 chemistry analytes in Saudis. Healthy individuals (n=826) aged ≥18 years were recruited using the global study protocol. All specimens were measured using an Architect analyzer. RIs were derived by both parametric and non-parametric methods for comparative purpose. The need for secondary exclusion of reference values based on latent abnormal values exclusion (LAVE) method was examined. The magnitude of variation attributable to gender, ages and regions was calculated by the standard deviation ratio (SDR). Sources of variations: age, BMI, physical exercise and smoking levels were investigated by using the multiple regression analysis. SDRs for gender, age and regional differences were significant for 14, 8 and 2 analytes, respectively. BMI-related changes in test results were noted conspicuously for CRP. For some metabolic related parameters the ranges of RIs by non-parametric method were wider than by the parametric method and RIs derived using the LAVE method were significantly different than those without it. RIs were derived with and without gender partition (BMI, drugs and supplements were considered). RIs applicable to Saudis were established for the majority of chemistry analytes, whereas gender, regional and age RI partitioning was required for some analytes. The elevated upper limits of metabolic analytes reflects the existence of high prevalence of metabolic syndrome in Saudi population.
Harmonising Reference Intervals for Three Calculated Parameters used in Clinical Chemistry.
Hughes, David; Koerbin, Gus; Potter, Julia M; Glasgow, Nicholas; West, Nic; Abhayaratna, Walter P; Cavanaugh, Juleen; Armbruster, David; Hickman, Peter E
2016-08-01
For more than a decade there has been a global effort to harmonise all phases of the testing process, with particular emphasis on the most frequently utilised measurands. In addition, it is recognised that calculated parameters derived from these measurands should also be a target for harmonisation. Using data from the Aussie Normals study we report reference intervals for three calculated parameters: serum osmolality, serum anion gap and albumin-adjusted serum calcium. The Aussie Normals study was an a priori study that analysed samples from 1856 healthy volunteers. The nine analytes used for the calculations in this study were measured on Abbott Architect analysers. The data demonstrated normal (Gaussian) distributions for the albumin-adjusted serum calcium, the anion gap (using potassium in the calculation) and the calculated serum osmolality (using both the Bhagat et al. and Smithline and Gardner formulae). To assess the suitability of these reference intervals for use as harmonised reference intervals, we reviewed data from the Royal College of Pathologists of Australasia/Australasian Association of Clinical Biochemists (RCPA/AACB) bias survey. We conclude that the reference intervals for the calculated serum osmolality (using the Smithline and Gardner formulae) may be suitable for use as a common reference interval. Although a common reference interval for albumin-adjusted serum calcium may be possible, further investigations (including a greater range of albumin concentrations) are needed. This is due to the bias between the Bromocresol Green (BCG) and Bromocresol Purple (BCP) methods at lower serum albumin concentrations. Problems with the measurement of Total CO 2 in the bias survey meant that we could not use the data for assessing the suitability of a common reference interval for the anion gap. Further study is required.
Reference intervals for 24 laboratory parameters determined in 24-hour urine collections.
Curcio, Raffaele; Stettler, Helen; Suter, Paolo M; Aksözen, Jasmin Barman; Saleh, Lanja; Spanaus, Katharina; Bochud, Murielle; Minder, Elisabeth; von Eckardstein, Arnold
2016-01-01
Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.
Higgins, Victoria; Chan, Man Khun; Nieuwesteeg, Michelle; Hoffman, Barry R; Bromberg, Irvin L; Gornall, Doug; Randell, Edward; Adeli, Khosrow
2016-01-01
The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has recently established pediatric age- and sex-specific reference intervals for over 85 biochemical markers on the Abbott Architect system. Previously, CALIPER reference intervals for several biochemical markers were successfully transferred from Abbott assays to Roche, Beckman, Ortho, and Siemens assays. This study further broadens the CALIPER database by performing transference and verification for 52 biochemical assays on the Roche cobas 6000 and the Roche Modular P. Using CLSI C28-A3 and EP9-A2 guidelines, transference of the CALIPER reference intervals was attempted for 16 assays on the Roche cobas 6000 and 36 on the Modular P. Calculated reference intervals were further verified using 100 healthy CALIPER samples. Most assays showed strong correlation between assay systems and were transferable from Abbott to the Roche cobas 6000 (81%) and the Modular P (86%). Bicarbonate and magnesium were not transferable on either system and calcium and prealbumin were not transferable to the Modular P. Of the transferable analytes, 62% and 61% were verified on the cobas 6000 and the Modular P, respectively. This study extends the utility of the CALIPER database to two additional analytical systems, which facilitates the broad application of CALIPER reference intervals at pediatric centers utilizing Roche biochemical assays. Transference studies across different analytical platforms can later be collectively analyzed in an attempt to develop common reference intervals across all clinical chemistry instruments to harmonize laboratory test interpretation in diagnosis and monitoring of pediatric disease. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Risch, Martin; Nydegger, Urs; Risch, Lorenz
2017-01-01
In clinical practice, laboratory results are often important for making diagnostic, therapeutic, and prognostic decisions. Interpreting individual results relies on accurate reference intervals and decision limits. Despite the considerable amount of resources in clinical medicine spent on elderly patients, accurate reference intervals for the elderly are rarely available. The SENIORLAB study set out to determine reference intervals in the elderly by investigating a large variety of laboratory parameters in clinical chemistry, hematology, and immunology. The SENIORLAB study is an observational, prospective cohort study. Subjectively healthy residents of Switzerland aged 60 years and older were included for baseline examination (n = 1467), where anthropometric measurements were taken, medical history was reviewed, and a fasting blood sample was drawn under optimal preanalytical conditions. More than 110 laboratory parameters were measured, and a biobank was set up. The study participants are followed up every 3 to 5 years for quality of life, morbidity, and mortality. The primary aim is to evaluate different laboratory parameters at age-related reference intervals. The secondary aims of this study include the following: identify associations between different parameters, identify diagnostic characteristics to diagnose different circumstances, identify the prevalence of occult disease in subjectively healthy individuals, and identify the prognostic factors for the investigated outcomes, including mortality. To obtain better grounds to justify clinical decisions, specific reference intervals for laboratory parameters of the elderly are needed. Reference intervals are obtained from healthy individuals. A major obstacle when obtaining reference intervals in the elderly is the definition of health in seniors because individuals without any medical condition and any medication are rare in older adulthood. Reference intervals obtained from such individuals cannot be considered representative for seniors in a status of age-specific normal health. In addition to the established methods for determining reference intervals, this longitudinal study utilizes a unique approach, in that survival and long-term well-being are taken as indicators of health in seniors. This approach is expected to provide robust and representative reference intervals that are obtained from an adequate reference population and not a collective of highly selected individuals. The present study was registered under International Standard Randomized Controlled Trial Number registry: ISRCTN53778569.
Knowles, Susan; Hrubec, Terry C; Smith, Stephen A; Bakal, Robert S
2006-12-01
The shortnose sturgeon, Acipenser brevirostrum, is an imperiled species distributed along the Atlantic coast of North America. Interest in replenishing wild stocks with hatchery-reared fish has created a need for accurate hematologic and biochemical reference intervals to evaluate the health of both fish raised in aquaculture systems and fish in the wild. The objective of this study was to generate hematologic and biochemistry reference intervals for healthy shortnose sturgeon. Blood samples were collected in heparinized tubes from 77 shortnose sturgeon raised in flow-through aquaculture systems. Whole blood and plasma samples were analyzed for hematologic and biochemical variables using standard techniques. Reference intervals were calculated as the central 95% (percentile) of data. Hematologic reference intervals (n = 46) were as follows: PCV 26-46%, hemoglobin 5.7-8.7 g/dL, MCV 307-520 fL, MCH 65.9-107.1 pg, MCHC 15-30 g/dL, plasma proteins (refractometry) 2.8-6.0 g/dL, RBC count 0.65-1.09 x 10(6)/microL, total WBC count 28,376-90,789/microL, small lymphocytes 9063-56,656/microL, large lymphocytes 2122-10,435/microL, neutrophils 3758-33,592/microL, monocytes 0-7137/microL, eosinophils 0-1544/microL, thrombocyte-like cells 6863-23,046/microL, thrombocytes 32,205-122,179/microL, and neutrophil:lymphocyte ratio 0.068-1.026. Plasma chemistry reference intervals (n = 77) were as follows: total protein 2.7-5.3 g/dL, albumin 0.8-1.7 g/dL, globulins 1.8-3.7 mg/dL, creatinine 0-1.4 mg/dL, total bilirubin 0-0.1 mg/dL, alkaline phosphatase 47-497 U/L, aspartate aminotransferase 90-311 U/L, sodium 124-141 mmol/L, potassium 2.9-3.7 mmol/L, chloride 106-121 mmol/L, calcium 6.6-12.1 mg/dL, magnesium 1.6-2.3 mg/dL, phosphorus 5.1-8.1 mg/dL, glucose 37-74 mg/dL, cholesterol 42-133 mg/dL, and osmolality 232-289 mOsm/kg. Reference values reported here will be useful for the early detection, identification, and monitoring of disease and sublethal conditions in cultured shortnose sturgeon.
Reference values for 34 frequently used laboratory tests in 80-year-old men and women.
Helmersson-Karlqvist, Johanna; Ridefelt, Peter; Lind, Lars; Larsson, Anders
2016-10-01
Reference values are usually based on blood samples from healthy individuals in the age range 20-50 years. Most patients seeking health care are older than this reference population. Many reference intervals are age dependent and there is thus a need to have appropriate reference intervals also for elderly individuals. We analyzed a group of frequently used laboratory tests in an 80-year-old population (n=531, 266 females and 265 males). The 2.5th and 97.5th percentiles for these markers were calculated according to the International Federation of Clinical Chemistry guidelines on the statistical treatment of reference values. Reference values are reported for serum alanine transaminase (ALT), albumin, alkaline phosphatase, pancreatic amylase, apolipoprotein A1, apolipoprotein B, apolipoprotein B/apolipoprotein A1 ratio, aspartate aminotransferase (AST), AST/ALT ratio, bilirubin, calcium, calprotectin, cholesterol, HDL-cholesterol, creatinine kinase (CK), creatinine, creatinine estimated GFR, C-reactive protein, cystatin C, cystatin C estimated GFR, gamma-glutamyltransferase (GGT), iron, iron saturation, lactate dehydrogenase (LDH), magnesium, phosphate, transferrin, triglycerides, urate, urea, zinc, hemoglobin, platelet count and white blood cell count. The upper reference limit for creatinine and urea was significantly increased while the lower limit for iron and albumin was decreased in this elderly population in comparison with the population in the Nordic Reference Interval Project (NORIP). Reference values calculated from the whole population and a subpopulation without cardiovascular disease showed strong concordance. Several of the reference interval limits were outside the 90% confidence interval of NORIP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Thoresen, Stein I; Arnemo, Jon M; Liberg, Olof
2009-06-01
Scandinavian free-ranging wolves (Canis lupus) are endangered, such that laboratory data to assess their health status is increasingly important. Although wolves have been studied for decades, most biological information comes from captive animals. The objective of the present study was to establish reference intervals for 30 clinical chemical and 8 hematologic analytes in Scandinavian free-ranging wolves. All wolves were tracked and chemically immobilized from a helicopter before examination and blood sampling in the winter of 7 consecutive years (1998-2004). Seventy-nine blood samples were collected from 57 gray wolves, including 24 juveniles (24 samples), 17 adult females (25 samples), and 16 adult males (30 samples). Whole blood and serum samples were stored at refrigeration temperature for 1-3 days before hematologic analyses and for 1-5 days before serum biochemical analyses. Reference intervals were calculated as 95% confidence intervals except for juveniles where the minimum and maximum values were used. Significant differences were observed between adult and juvenile wolves for RBC parameters, alkaline phosphatase and amylase activities, and total protein, albumin, gamma-globulins, cholesterol, creatinine, calcium, chloride, magnesium, phosphate, and sodium concentrations. Compared with published reference values for captive wolves, reference intervals for free-ranging wolves reflected exercise activity associated with capture (higher creatine kinase activity, higher glucose concentration), and differences in nutritional status (higher urea concentration).
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Biological covariates such as age and sex can markedly influence biochemical marker reference values, but no comprehensive study has examined such changes across pediatric, adult, and geriatric ages. The Canadian Health Measures Survey (CHMS) collected comprehensive nationwide health information and blood samples from children and adults in the household population and, in collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), examined biological changes in biochemical markers from pediatric to geriatric age, establishing a comprehensive reference interval database for routine disease biomarkers. The CHMS collected health information, physical measurements, and biosamples (blood and urine) from approximately 12 000 Canadians aged 3-79 years and measured 24 biochemical markers with the Ortho Vitros 5600 FS analyzer or a manual microplate. By use of CLSI C28-A3 guidelines, we determined age- and sex-specific reference intervals, including corresponding 90% CIs, on the basis of specific exclusion criteria. Biochemical marker reference values exhibited dynamic changes from pediatric to geriatric age. Most biochemical markers required some combination of age and/or sex partitioning. Two or more age partitions were required for all analytes except bicarbonate, which remained constant throughout life. Additional sex partitioning was required for most biomarkers, except bicarbonate, total cholesterol, total protein, urine iodine, and potassium. Understanding the fluctuations in biochemical markers over a wide age range provides important insight into biological processes and facilitates clinical application of biochemical markers to monitor manifestation of various disease states. The CHMS-CALIPER collaboration addresses this important evidence gap and allows the establishment of robust pediatric and adult reference intervals. © 2015 American Association for Clinical Chemistry.
Kostecka-Matyja, Marta; Fedorowicz, Anna; Bar-Andziak, Ewa; Bednarczuk, Tomasz; Buziak-Bereza, Monika; Dumnicka, Paulina; Górska, Maria; Krasnodębska, Małgorzata; Niedźwiedzka, Beata; Pach, Dorota; Ruchała, Marek; Siewko, Katarzyna; Solnica, Bogdan; Sowiński, Jerzy; Szelachowska, Małgorzata; Trofimiuk-Müldner, Małgorzata; Wachowiak-Ochmańska, Katarzyna; Hubalewska-Dydejczyk, Alicja
2017-04-01
The diagnosis and treatment of thyroid diseases in pregnant women remains a challenge. Various medical associations recommend establishing the reference intervals for thyroid hormones by a local laboratory. Considering differences within geophysical, socioeconomic conditions, and iodine prophylaxis in various populations, it is advisable to assess reference intervals for thyroid hormones specific to a region of residence. The objective was to assess trimester-specific reference intervals for TSH, fT 3 , and fT 4 for pregnant women in the Polish population. We conducted a prospective study in 4 centers representing different regions of Poland (Krakow, Warsaw, Poznan, and Bialystok). Our study included consecutive, healthy pregnant women (172 patients), with an age range of 27-47 years. All women had a negative history for thyroid diseases, normal thyroid peroxidase antibody levels, and proper iodine prophylaxis. All newborns had TSH levels in the appropriate reference range. Serum TSH, fT 3 , fT 4 , and thyroid-peroxidase antibodies were measured in each trimester. The reference intervals were calculated using the percentile method, as recommended by the International Federation of Clinical Chemistry. The reference values calculated were 0.009-3.177, 0.05-3.442, and 0.11-3.53 mIU/L for TSH; 3.63-6.55, 3.29-5.45, and 3.1-5.37 pmol/L for fT 3 ; and 11.99-21.89, 10.46-16.67, and 8.96-17.23 pmol/L for fT 4 in consecutive trimesters of pregnancy. Reference intervals for pregnant women when compared to the general population showed a lower concentration of TSH in every trimester of pregnancy and lower fT 4 in the 2nd and 3rd trimesters. Using appropriate trimester-specific reference intervals may improve care of pregnant women by preventing misdiagnosis and inadequate treatment.
Mørkrid, Lars; Rowe, Alexander D; Elgstoen, Katja B P; Olesen, Jess H; Ruijter, George; Hall, Patricia L; Tortorelli, Silvia; Schulze, Andreas; Kyriakopoulou, Lianna; Wamelink, Mirjam M C; van de Kamp, Jiddeke M; Salomons, Gajja S; Rinaldo, Piero
2015-05-01
Urinary concentrations of creatine and guanidinoacetic acid divided by creatinine are informative markers for cerebral creatine deficiency syndromes (CDSs). The renal excretion of these substances varies substantially with age and sex, challenging the sensitivity and specificity of postanalytical interpretation. Results from 155 patients with CDS and 12 507 reference individuals were contributed by 5 diagnostic laboratories. They were binned into 104 adjacent age intervals and renormalized with Box-Cox transforms (Ξ). Estimates for central tendency (μ) and dispersion (σ) of Ξ were obtained for each bin. Polynomial regression analysis was used to establish the age dependence of both μ[log(age)] and σ[log(age)]. The regression residuals were then calculated as z-scores = {Ξ - μ[log(age)]}/σ[log(age)]. The process was iterated until all z-scores outside Tukey fences ±3.372 were identified and removed. Continuous percentile charts were then calculated and plotted by retransformation. Statistically significant and biologically relevant subgroups of z-scores were identified. Significantly higher marker values were seen in females than males, necessitating separate reference intervals in both adolescents and adults. Comparison between our reconstructed reference percentiles and current standard age-matched reference intervals highlights an underlying risk of false-positive and false-negative events at certain ages. Disease markers depending strongly on covariates such as age and sex require large numbers of reference individuals to establish peripheral percentiles with sufficient precision. This is feasible only through collaborative data sharing and the use of appropriate statistical methods. Broad application of this approach can be implemented through freely available Web-based software. © 2015 American Association for Clinical Chemistry.
Stacy, Nicole I; Bjorndal, Karen A; Perrault, Justin R; Martins, Helen R; Bolten, Alan B
2018-01-01
Blood analyte reference intervals are scarce for immature life stages of the loggerhead sea turtle ( Caretta caretta ). The objectives of this study were to (1) document reference intervals of packed cell volume (PCV) and 20 plasma chemistry analytes from wild oceanic-juvenile stage loggerhead turtles from Azorean waters, (2) investigate correlations with body size (minimum straight carapace length: SCL min ) and (3) compare plasma chemistry data to those from older, larger neritic juveniles (<80 cm SCL min ) and adult loggerheads (≥80 cm SCL min ) that have recruited to the West Atlantic in waters around Cape Canaveral, Florida. Twenty-eight Azorean loggerhead turtles with SCL min of 17.6-60.0 cm (mean 34.9 ± 12.1 cm) were captured, sampled and immediately released. Reference intervals are reported. There were several biologically relevant correlations of blood analytes with SCL min : positive correlations of PCV, proteins and triglycerides with SCL min indicated somatic growth, increasing diving activity and/or diet; negative correlations of tissue enzymes with SCL min suggested faster growth at smaller turtle size, while negative correlations of electrolytes with SCL min indicated differences in diet, environmental conditions and/or osmoregulation unique to the geographic location. Comparisons of loggerhead turtles from the Azores (i.e. oceanic) and Cape Canaveral (i.e. neritic) identified significant differences regarding diet, somatic growth, and/or environment: in Azorean turtles, albumin, triglycerides and bilirubin increased with SCL min , while alkaline phosphatase, lactate dehydrogenase and sodium decreased. In larger neritic Cape Canaveral turtles, aspartate aminotransferase increased with SCL min , while the albumin:globulin ratio, phosphorus and cholesterol decreased. These differences suggest unique physiological disparities between life stage development and migration, reflecting biological and habitat differences between the two populations. This information presents biologically important data that is applicable to stranded individual turtles and to the population level, a tool for the development of conservation strategies, and a baseline for future temporal and spatial investigations of the Azorean loggerhead sea turtle population.
Bjorndal, Karen A; Perrault, Justin R; Martins, Helen R; Bolten, Alan B
2018-01-01
Abstract Blood analyte reference intervals are scarce for immature life stages of the loggerhead sea turtle (Caretta caretta). The objectives of this study were to (1) document reference intervals of packed cell volume (PCV) and 20 plasma chemistry analytes from wild oceanic-juvenile stage loggerhead turtles from Azorean waters, (2) investigate correlations with body size (minimum straight carapace length: SCLmin) and (3) compare plasma chemistry data to those from older, larger neritic juveniles (<80 cm SCLmin) and adult loggerheads (≥80 cm SCLmin) that have recruited to the West Atlantic in waters around Cape Canaveral, Florida. Twenty-eight Azorean loggerhead turtles with SCLmin of 17.6–60.0 cm (mean 34.9 ± 12.1 cm) were captured, sampled and immediately released. Reference intervals are reported. There were several biologically relevant correlations of blood analytes with SCLmin: positive correlations of PCV, proteins and triglycerides with SCLmin indicated somatic growth, increasing diving activity and/or diet; negative correlations of tissue enzymes with SCLmin suggested faster growth at smaller turtle size, while negative correlations of electrolytes with SCLmin indicated differences in diet, environmental conditions and/or osmoregulation unique to the geographic location. Comparisons of loggerhead turtles from the Azores (i.e. oceanic) and Cape Canaveral (i.e. neritic) identified significant differences regarding diet, somatic growth, and/or environment: in Azorean turtles, albumin, triglycerides and bilirubin increased with SCLmin, while alkaline phosphatase, lactate dehydrogenase and sodium decreased. In larger neritic Cape Canaveral turtles, aspartate aminotransferase increased with SCLmin, while the albumin:globulin ratio, phosphorus and cholesterol decreased. These differences suggest unique physiological disparities between life stage development and migration, reflecting biological and habitat differences between the two populations. This information presents biologically important data that is applicable to stranded individual turtles and to the population level, a tool for the development of conservation strategies, and a baseline for future temporal and spatial investigations of the Azorean loggerhead sea turtle population. PMID:29479433
Evaluation of an in-practice wet-chemistry analyzer using canine and feline serum samples.
Irvine, Katherine L; Burt, Kay; Papasouliotis, Kostas
2016-01-01
A wet-chemistry biochemical analyzer was assessed for in-practice veterinary use. Its small size may mean a cost-effective method for low-throughput in-house biochemical analyses for first-opinion practice. The objectives of our study were to determine imprecision, total observed error, and acceptability of the analyzer for measurement of common canine and feline serum analytes, and to compare clinical sample results to those from a commercial reference analyzer. Imprecision was determined by within- and between-run repeatability for canine and feline pooled samples, and manufacturer-supplied quality control material (QCM). Total observed error (TEobs) was determined for pooled samples and QCM. Performance was assessed for canine and feline pooled samples by sigma metric determination. Agreement and errors between the in-practice and reference analyzers were determined for canine and feline clinical samples by Bland-Altman and Deming regression analyses. Within- and between-run precision was high for most analytes, and TEobs(%) was mostly lower than total allowable error. Performance based on sigma metrics was good (σ > 4) for many analytes and marginal (σ > 3) for most of the remainder. Correlation between the analyzers was very high for most canine analytes and high for most feline analytes. Between-analyzer bias was generally attributed to high constant error. The in-practice analyzer showed good overall performance, with only calcium and phosphate analyses identified as significantly problematic. Agreement for most analytes was insufficient for transposition of reference intervals, and we recommend that in-practice-specific reference intervals be established in the laboratory. © 2015 The Author(s).
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-07-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions.
Clinical chemistry reference values for 75-year-old apparently healthy persons.
Huber, Klaus Roland; Mostafaie, Nazanin; Stangl, Gerhard; Worofka, Brigitte; Kittl, Eva; Hofmann, Jörg; Hejtman, Milos; Michael, Rainer; Weissgram, Silvia; Leitha, Thomas; Jungwirth, Susanne; Fischer, Peter; Tragl, Karl-Heinz; Bauer, Kurt
2006-01-01
Clinical chemistry reference values for elderly persons are sparse and mostly intermixed with those for younger subjects. To understand the links between metabolism and aging, it is paramount to differentiate between "normal" physiological processes in apparently healthy elderly subjects and metabolic changes due to long-lasting diseases. The Vienna Transdanube Aging (VITA) study, which began in 2000 and is continuing, will allow us to do just that, because more than 600 male and female volunteers aged exactly 75 years (to exclude any influence of the "aging" factor in this cohort) are participating in this study. Extensive clinical, neurological, biochemical, psychological, genetic, and radiological analyses, with a special emphasis on consumption of medication and abuse of drugs, were performed on each of the probands. The multitude of data and questionnaires obtained made possible an a posteriori approach to select individuals fulfilling criteria for a reference sample group of apparently healthy 75-year-old subjects for our study. Specific analytes were quantified on automated clinical analyzers, while manual methods were used for hormonal analytes. All clinical chemistry analytes were evaluated using in-depth statistical analyses with SPSS for Windows. In all, reference intervals for 45 analytes could be established. These include routine parameters for the assessment of organ functions, as well as hormone concentrations and hematological appraisals. Because all patients were reevaluated after exactly 30 months in the course of this study, we had the opportunity to reassess their health status at the age of 77.5 years. This was very useful for validation of the first round data set. Data of the second round evaluation corroborate the reference limits of the baseline analysis and further confirm our inclusion and exclusion criteria. In summary, we have established a reliable set of reference data for hormonal, hematological, and clinical chemistry analytes for elderly subjects. These values will be very useful for our future attempts to correlate disease states and aging processes with metabolic factors.
Verification of chemistry reference ranges using a simple method in sub-Saharan Africa
Taylor, Douglas; Mandala, Justin; Nanda, Kavita; Van Campenhout, Christel; Agingu, Walter; Madurai, Lorna; Barsch, Eva-Maria; Deese, Jennifer; Van Damme, Lut; Crucitti, Tania
2016-01-01
Background Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs). Verification of CRRs is time consuming and often requires a statistical background. Objectives We report on an easy and cost-saving method to verify CRRs. Methods Using a former method introduced by Sigma Diagnostics, three study sites in sub-Saharan Africa, Bondo, Kenya, and Pretoria and Bloemfontein, South Africa, verified the CRRs for hepatic and renal biochemistry assays performed during a clinical trial of HIV antiretroviral pre-exposure prophylaxis. The aspartate aminotransferase/alanine aminotransferase, creatinine and phosphorus results from 10 clinically-healthy participants at the screening visit were used. In the event the CRRs did not pass the verification, new CRRs had to be calculated based on 40 clinically-healthy participants. Results Within a few weeks, the study sites accomplished verification of the CRRs without additional costs. The aspartate aminotransferase reference ranges for the Bondo, Kenya site and the alanine aminotransferase reference ranges for the Pretoria, South Africa site required adjustment. The phosphorus CRR passed verification and the creatinine CRR required adjustment at every site. The newly-established CRR intervals were narrower than the CRRs used previously at these study sites due to decreases in the upper limits of the reference ranges. As a result, more toxicities were detected. Conclusion To ensure the safety of clinical trial participants, verification of CRRs should be standard practice in clinical trials conducted in settings where the CRR has not been validated for the local population. This verification method is simple, inexpensive, and can be performed by any medical laboratory. PMID:28879112
Verification of chemistry reference ranges using a simple method in sub-Saharan Africa.
De Baetselier, Irith; Taylor, Douglas; Mandala, Justin; Nanda, Kavita; Van Campenhout, Christel; Agingu, Walter; Madurai, Lorna; Barsch, Eva-Maria; Deese, Jennifer; Van Damme, Lut; Crucitti, Tania
2016-01-01
Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs). Verification of CRRs is time consuming and often requires a statistical background. We report on an easy and cost-saving method to verify CRRs. Using a former method introduced by Sigma Diagnostics, three study sites in sub-Saharan Africa, Bondo, Kenya, and Pretoria and Bloemfontein, South Africa, verified the CRRs for hepatic and renal biochemistry assays performed during a clinical trial of HIV antiretroviral pre-exposure prophylaxis. The aspartate aminotransferase/alanine aminotransferase, creatinine and phosphorus results from 10 clinically-healthy participants at the screening visit were used. In the event the CRRs did not pass the verification, new CRRs had to be calculated based on 40 clinically-healthy participants. Within a few weeks, the study sites accomplished verification of the CRRs without additional costs. The aspartate aminotransferase reference ranges for the Bondo, Kenya site and the alanine aminotransferase reference ranges for the Pretoria, South Africa site required adjustment. The phosphorus CRR passed verification and the creatinine CRR required adjustment at every site. The newly-established CRR intervals were narrower than the CRRs used previously at these study sites due to decreases in the upper limits of the reference ranges. As a result, more toxicities were detected. To ensure the safety of clinical trial participants, verification of CRRs should be standard practice in clinical trials conducted in settings where the CRR has not been validated for the local population. This verification method is simple, inexpensive, and can be performed by any medical laboratory.
Harvey, Stephen B; Krimer, Paula M; Correa, Maria T; Hanes, Martha A
2008-01-01
Plasma biochemical and hematologic values are important parameters for assessing animal health and experimental results. Although normal reference values for many rodent species have been published, there is a dearth of similar information for the genus Microtus. In addition, most studies use a mean and standard deviation to establish reference intervals, but doing so is not the recommendation of the Clinical and Laboratory Standards Institute (formerly the National Committee on Clinical Laboratory Standards) or the International Federation of Clinical Chemistry and Laboratory Medicine. The purpose of this study was to establish normal reference parameters for plasma biochemistry and hematology in mature pine voles (Microtus pinetorum) by using the nonparametric rank percentile method as recommended by the 2 laboratory medicine organizations mentioned. Samples of cardiac blood from a closed colony of pine voles were collected at euthanasia and evaluated under rodent settings on 2 automated hematology analyzers from 2 different manufacturers and on the same type of automated biochemistry analyzer. There were no sex-associated clinically significant differences between the sexes; younger animals had a lower hematocrit, higher mean corpuscular volume, and lower mean corpuscular hemoglobin concentration than did older animals. Only platelet counts differed when comparing hematologic values from different analyzers. Relative to rats and mice, pine voles have a lower mean corpuscular volume and higher red blood cell count, higher blood urea nitrogen, much higher alanine aminotransferase, and lower glucose and phosphorous concentrations. Hematology and plasma biochemical results obtained in this study are considered representative for healthy adult laboratory pine voles under similar environmental conditions. PMID:18702449
DiVincenti, Louis; Priest, Heather; Walker, Kyle J.; Wyatt, Jeffrey D.; Dittman, Dawn
2013-01-01
Hematology and serum chemistry analytes were compared between wild-caught and aquarium-housed lake sturgeon (Acipenser fulvescens) to potentially improve understanding of medical issues in lake sturgeon. Blood samples were taken from 30 lake sturgeon exhibited in 11 institutions in the United States and from 23 experimentally stocked lake sturgeon caught in gill nets in the lower Genesee River in Rochester, New York, USA. For hematology, only segmented neutrophil count was significantly different, with wild-caught fish having a higher number of circulating neutrophils. For clinical chemistry analytes, chloride, uric acid, calcium, phosphate, glucose, aspartate aminotransferase, triglycerides, and creatine kinase were significantly different between the two cohorts. These differences are likely not clinically significant and are attributable to handling stress, variability in environmental parameters, or differences in nutritional status. This is the first report of hematology and serum chemistry values in aquarium-housed lake sturgeon and provides useful reference intervals for clinicians.
Fernández-Cidón, Bárbara; Padró-Miquel, Ariadna; Alía-Ramos, Pedro; Castro-Castro, María José; Fanlo-Maresma, Marta; Dot-Bach, Dolors; Valero-Politi, José; Pintó-Sala, Xavier; Candás-Estébanez, Beatriz
2017-01-01
High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c) particles are associated with risk of cardiovascular disease (CVD). Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg 2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c) from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation). Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. The Passing-Bablok regression equation is y = 1.52 (0.72 to 1.73) + 0.07 x (-0.1 to 0.13), demonstrating no significant statistical differences between the modified precipitation method and the ultracentrifugation reference method. Similarly, no differences were detected when considering only sd-LDL-c from dyslipidemic patients, since the modifications added to the precipitation method facilitated the proper sedimentation of triglycerides and other lipoproteins. The reference interval for sd-LDL-c concentration estimated in a Mediterranean population was 0.04-0.47 mmol/L. An optimization of the heparin-Mg 2+ precipitation method for sd-LDL particle isolation was performed, and reference intervals were established in a Spanish Mediterranean population. Measured values were equivalent to those obtained with the reference method, assuring its clinical application when tested in both normolipidemic and dyslipidemic subjects.
Reference intervals: current status, recent developments and future considerations.
Ozarda, Yesim
2016-01-01
Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term 'RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs.
Reference intervals: current status, recent developments and future considerations
Ozarda, Yesim
2016-01-01
Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term ‘RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs. PMID:26981015
Expressing analytical performance from multi-sample evaluation in laboratory EQA.
Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M
2017-08-28
To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.
López, Javier; Waters, Michael; Routh, Andrew; Rakotonanahary, Tsanta F; Woolaver, Lance; Thomasson, Ann; Holmes, Emma; Steinmetz, Hanspeter W
2017-03-01
Blood samples from 172 captive and 40 wild, healthy, juvenile and adult, ploughshare tortoises ( Astrochelys yniphora ) were analyzed to determine hematological and biochemical reference intervals. Hematological analytes included packed cell volume (PCV), white blood cell count (WBC), and WBC differential estimates. Biochemical analysis included total protein measured by photometry (TP) and by refractometry (TPr), albumin (ALB), creatine kinase (CK), aspartate aminotransferase (AST), glutamate dehydrogenase (GLDH), bile acids (BA), calcium (Ca), phosphorus (P), urea (UREA), and uric acid (UA). The jugular vein was identified as the preferred venipuncture site as subcarapacial vein venipuncture resulted in regular hemodilution. In due consideration of small sample sizes in some of the groups studied, adult tortoises had significantly higher plasma GLDH activity and TPr, TP, ALB, BA, and UREA concentrations and significantly lower AST activity and P concentration than juveniles. Captivity had a significant influence in some reference intervals, with captive adults presenting significantly higher WBC, and estimated counts of all white cell types as well as UREA and TPr than wild counterparts. Captive juveniles also showed significantly higher estimated monocyte and lower estimated eosinophil and basophil counts. Although these differences most likely reflect local environmental or dietary differences, without representing pathology or a deviation from the normal, they question the applicability of reference values from captive animals to wild animals and vice versa. Significant sex differences were only observed for PCV and UA. The reported reference intervals may serve as benchmarks for clinical assessment and conservation of this critically endangered species.
Erlandsen, Erland J; Randers, Else
2010-07-01
To evaluate the performance of the Roche Diagnostics Tina-quant Cystatin C particle enhanced immuno turbidimetric assay for the measurement of plasma and serum cystatin C, and to establish reference intervals for cystatin C in healthy blood donors. The cystatin C measurements were performed on the Roche Modular Analytics P automated clinical chemistry analyzer. The cystatin C assay was linear in the measuring range 0.40-7.00 mg/L. Within-run CVs < or = 2.0%, between-run CVs < or = 4.2%, and total CVs < or = 5.5% in plasma pools and in commercial cystatin C control materials (range 1.0-4.7 mg/L). Recovery was 99.4-109.3%. No interference was detected from haemoglobin < 0.9 mmol/L, bilirubin < 330 micromol/L and Intralipid < 20 g/L. Measurement of cystatin C in Li-heparin plasma did not differ significantly from cystatin C measured in serum. Forty patient samples run on the Modular Analytics P (y) were compared to the Siemens Cystatin C assay on the BN II (x): y = 0.817x + 0.270, Sy.x = 0.168 (Deming regression). The non-parametric reference interval for cystatin C was calculated to be 0.41-0.91 mg/L in females (n = 86), and 0.43-0.94 mg/L in males (n = 76). The Mann-Whitney U test showed a significant difference between the two genders (p = 0.015), but the difference was without clinical relevance. A common reference interval for both genders (n = 162) was calculated to be 0.41-0.92 mg/L. The performance of the Tina-quant Cystatin C assay was acceptable for clinical use.
Recommendation for the review of biological reference intervals in medical laboratories.
Henny, Joseph; Vassault, Anne; Boursier, Guilaine; Vukasovic, Ines; Mesko Brguljan, Pika; Lohmander, Maria; Ghita, Irina; Andreu, Francisco A Bernabeu; Kroupis, Christos; Sprongl, Ludek; Thelen, Marc H M; Vanstapel, Florent J L A; Vodnik, Tatjana; Huisman, Willem; Vaubourdolle, Michel
2016-12-01
This document is based on the original recommendation of the Expert Panel on the Theory of Reference Values of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), updated guidelines were recently published under the auspices of the IFCC and the Clinical and Laboratory Standards Institute (CLSI). This document summarizes proposals for recommendations on: (i) The terminology, which is often confusing, noticeably concerning the terms of reference limits and decision limits. (ii) The method for the determination of reference limits according to the original procedure and the conditions, which should be used. (iii) A simple procedure allowing the medical laboratories to fulfill the requirements of the regulation and standards. The updated document proposes to verify that published reference limits are applicable to the laboratory involved. Finally, the strengths and limits of the revised recommendations (especially the selection of the reference population, the maintenance of the analytical quality, the choice of the statistical method used…) will be briefly discussed.
Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako
2016-01-01
Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.
Age-dependent biochemical quantities: an approach for calculating reference intervals.
Bjerner, J
2007-01-01
A parametric method is often preferred when calculating reference intervals for biochemical quantities, as non-parametric methods are less efficient and require more observations/study subjects. Parametric methods are complicated, however, because of three commonly encountered features. First, biochemical quantities seldom display a Gaussian distribution, and there must either be a transformation procedure to obtain such a distribution or a more complex distribution has to be used. Second, biochemical quantities are often dependent on a continuous covariate, exemplified by rising serum concentrations of MUC1 (episialin, CA15.3) with increasing age. Third, outliers often exert substantial influence on parametric estimations and therefore need to be excluded before calculations are made. The International Federation of Clinical Chemistry (IFCC) currently recommends that confidence intervals be calculated for the reference centiles obtained. However, common statistical packages allowing for the adjustment of a continuous covariate do not make this calculation. In the method described in the current study, Tukey's fence is used to eliminate outliers and two-stage transformations (modulus-exponential-normal) in order to render Gaussian distributions. Fractional polynomials are employed to model functions for mean and standard deviations dependent on a covariate, and the model is selected by maximum likelihood. Confidence intervals are calculated for the fitted centiles by combining parameter estimation and sampling uncertainties. Finally, the elimination of outliers was made dependent on covariates by reiteration. Though a good knowledge of statistical theory is needed when performing the analysis, the current method is rewarding because the results are of practical use in patient care.
Lemoy, Marie-Josee MF; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P
2013-01-01
The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 µmol/L and postprandial SBAC was 19.7 ± 8.0 µmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals. PMID:23849441
Lemoy, Marie-Josee M F; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P
2013-07-01
The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 μmol/L and postprandial SBAC was 19.7 ± 8.0 μmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals.
Age-dependent changes in plasma biochemistry of yellow-legged gulls (Larus cachinnans).
Alonso-Alvarez, Carlos
2005-04-01
The study of avian plasma chemistry is providing useful reference values for the management of endangered and game species, supporting veterinarians in their diagnostics, and also bringing to light relevant physiological adaptations during periods of food-shortage. Age is an important source of variability for plasma chemistry. Here I report plasma chemistry of yellow-legged gulls Larus cachinnans from different ages, between post-independence and adulthood, a 5-year interval. Increase in plasma cholesterol concentration and decreases in uric acid, inorganic phosphorus and alkaline phosphatase values were seen. Body mass corrected by body size (i.e. body condition) increased with age, plasma cholesterol being positively correlated in females, but not in males. Moreover, cholesterol was also positively correlated to gonad size in both sexes. Long-term developmental changes in this species, such as gonad development and the acquisition of an optimal body mass for reproduction, could explain these findings. Finally, inorganic phosphorus and alkaline phosphatase, both traditionally related to osteogenesis, were not associated to deferred skull ossification, as originally was suggested in other species.
Da Molin, Simona; Cappellini, Fabrizio; Falbo, Rosanna; Signorini, Stefano; Brambilla, Paolo
2014-11-01
Heart-type fatty acid-binding protein (H-FABP) is an early biomarker of cardiac injury. Randox Laboratories developed an immunoturbidimetric H-FABP assay for non-proprietary automated clinical chemistry analysers that could be useful in the emergency department. We verified the analytical performances claimed by Randox Laboratories on Roche Cobas 6000 clinical chemistry platform in use in our laboratory, and we defined our own 99th percentile upper reference limit for H-FABP. For the verification of method performances, we used pools of spared patient samples from routine and two levels of quality control material, while samples for the reference value study were collected from 545 blood donors. Following CLSI guidelines we verified limit of blank (LOB), limit of detection (LOD), limit of quantitation (LOQ), repeatability and within-laboratory precision, trueness, linearity, and the stability of H-FABP in EDTA over 24h. The LOQ (3.19 μg/L) was verified with a CV% of 10.4. The precision was verified for the low (mean 5.88 μg/L, CV=6.7%), the medium (mean 45.28 μg/L, CV=3.0%), and the high concentration (mean 88.81 μg/L, CV=4.0%). The trueness was verified as well as the linearity over the indicated measurement interval of 0.747-120 μg/L. The H-FABP in EDTA samples is stable throughout 24h both at room temperature and at 4 °C. The H-FABP 99th percentile upper reference limit for all subjects (3.60 μg/L, 95% CI 3.51-3.77) is more appropriate than gender-specific ones that are not statistically different. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Wu, Alan H B; Christenson, Robert H; Greene, Dina N; Jaffe, Allan S; Kavsak, Peter A; Ordonez-Llanos, Jordi; Apple, Fred S
2018-04-01
This document is an essential companion to the third iteration of the National Academy of Clinical Biochemistry [NACB, 8 now the American Association for Clinical Chemistry (AACC) Academy] Laboratory Medicine Practice Guidelines (LMPG) on cardiac markers. The expert consensus recommendations were drafted in collaboration with the International Federation of Clinical Chemistry and Laboratory Medicine Task Force on Clinical Applications of Bio-Markers (IFCC TF-CB). We determined that there is sufficient clinical guidance on the use of cardiac troponin (cTn) testing from clinical practice groups. Thus, in this expert consensus document, we focused on clinical laboratory practice recommendations for high-sensitivity (hs)-cTn assays. This document utilized the expert opinion class of evidence to focus on the following 10 topics: ( a ) quality control (QC) utilization, ( b ) validation of the lower reportable analytical limits, ( c ) units to be used in reporting measurable concentrations for patients and QC materials, ( d ) 99th percentile sex-specific upper reference limits to define the reference interval; ( e ) criteria required to define hs-cTn assays, ( f ) communication with clinicians and the laboratory's role in educating clinicians regarding the influence of preanalytic and analytic problems that can confound assay results, ( g ) studies on hs-cTn assays and how authors need to document preanalytical and analytical variables, ( h ) harmonizing and standardizing assay results and the role of commutable materials, ( i ) time to reporting of results from sample receipt and sample collection, and ( j ) changes in hs-cTn concentrations over time and the role of both analytical and biological variabilities in interpreting results of serial blood collections. © 2017 American Association for Clinical Chemistry.
Khoury, Cheryl; Werry, Kate; Haines, Douglas; Walker, Mike; Malowany, Morie
2018-05-01
The Canadian Health Measures Survey collects nationally representative human biomonitoring data on a suite of chemicals and their metabolites, including many non-persistent chemicals. Data has been collected on non-persistent chemicals, including acrylamide, chlorophenols, environmental phenols and triclocarban, organophosphate insecticides, phthalates, polycyclic aromatic hydrocarbon, pyrethroid insecticides, and volatile organic compounds from 2009 to 2013. Using a systematic approach building on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry, we derive human biomonitoring reference values (RV 95 s) for these classes of non-persistent chemicals in blood and urine for the general Canadian population. RV 95 s were derived for biomarkers of non-persistent chemicals with widespread detection in Canadians (>66% detection rate). Samples with urinary creatinine levels outside the recommended range of 0.3-3.0 μg/L were excluded. Reference populations were constructed by applying smoking and fasting as exclusion criteria where appropriate. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for sub-populations in cases where partitioning was deemed necessary. Reference values were derived for 40 biomarkers and represent the first set of RV 95 s for non-persistent chemicals in the general Canadian population. These values provide a measure of the upper margin of background exposure in the general population and can be compared against individual and population human biomonitoring data. RV 95 s can be used to by public health officials to identify individuals with high exposures, and by risk assessors and risk managers to identify atypical exposures or subpopulations with elevated exposures. Crown Copyright © 2018. Published by Elsevier GmbH. All rights reserved.
Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie
2017-11-01
Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Research into Practice: Visualising the Molecular World for a Deep Understanding of Chemistry
ERIC Educational Resources Information Center
Tasker, Roy
2014-01-01
Why is chemistry so difficult? A seminal paper by Johnstone (1982) offered an explanation for why science in general, and chemistry in particular, is so difficult to learn. He proposed that an expert in chemistry thinks at three levels; the macro (referred to as the observational level in this article), the sub-micro (referred to as the molecular…
Arkhipkin, A A; Liang, O V; Kochetov, A G
2014-10-01
The study was carried out to determine the prognostic value of alpha-fetoprotein in development of lethal outcome and degree of functional rehabilitation of patients with ischemic stroke. The sampling included 216 patients in acute period of ischemic stroke. At the first day of development of disease they were measured the level of human alpha-fetoprotein. At the second day of disease patients were evaluated the degree of functional rehabilitation and the rate of lethal outcomes was calculated. Previously, the reference interval for alpha-fetoprotein was calculated according the guidelines of the International federation of clinical chemistry and national standard. The reference interval amounted to 0.59-3.78 mE/l. The study results demonstrated that low level of alpha-fetoprotein is related to higher risk of lethal outcome (SE=1.7, p=0.012). The increasing of level of alpha-fetoprotein over mentioned threshold value statistically significant increases probability of survival of patients. The further increasing more than 2.28 mE/l is related to subsequent good functional rehabilitation according the modifies Rankine scale (SE=1.4, p=0.001) and Barthel index (SE=1.49, p<0.001).
Impact of the ovarian cycle and pregnancy on plasma chemistry values in ewes
Zywicki, Micaela E.; Blohowiak, Sharon E.; Magness, Ronald R.; Segar, Jeffrey L.; Kling, Pamela J.
2018-01-01
Normative data for plasma chemistry values in pregnant and non-pregnant reproductive age ewes are scant. Availability of data would aid monitoring of ewe health for both research and veterinary medicine. We determined specific plasma chemistry 95% confidence reference intervals (RIs) in non-pregnant and pregnant ewes. Mixed Western-breed ewes were grouped based on phase of ovarian cycle: luteal (n = 15), follicular (n = 17), or late-gestation pregnant (n = 102). Plasma samples were collected for analysis on a commercial biochemical analyzer. For RIs, chemistry panels for the 3 groups of ewes included nutrients and metabolites (glucose, triglycerides, cholesterol, urea, creatinine, total protein, albumin, and bilirubin), enzymes (lactate dehydrogenase, aspartate transaminase, gamma-glutamyl transferase, alanine aminotransferase, and alkaline phosphatase [ALP]), and micronutrients (calcium, phosphorus, iron, sodium, potassium, and chloride). Sample chemistry values for glucose and total protein in pregnant ewes were lower than in follicular ewes; cholesterol was lower in pregnant and luteal ewes than in follicular ewes. In addition, total bilirubin in pregnant ewes differed from that in luteal ewes, and that in follicular ewes also differed from luteal ewes. ALP in pregnant ewes was higher than other groups; phosphorus in pregnant ewes was lower than in luteal ewes. Iron was higher in pregnant ewes than in luteal ewes, with iron in luteal ewes lower than in follicular ewes. These data provide clinical RIs comparing pregnant and non-pregnant ewes for use in monitoring ewe health in both human research and veterinary medicine. PMID:29291683
Impact of the ovarian cycle and pregnancy on plasma chemistry values in ewes.
Zywicki, Micaela E; Blohowiak, Sharon E; Magness, Ronald R; Segar, Jeffrey L; Kling, Pamela J
2018-03-01
Normative data for plasma chemistry values in pregnant and non-pregnant reproductive age ewes are scant. Availability of data would aid monitoring of ewe health for both research and veterinary medicine. We determined specific plasma chemistry 95% confidence reference intervals (RIs) in non-pregnant and pregnant ewes. Mixed Western-breed ewes were grouped based on phase of ovarian cycle: luteal ( n = 15), follicular ( n = 17), or late-gestation pregnant ( n = 102). Plasma samples were collected for analysis on a commercial biochemical analyzer. For RIs, chemistry panels for the 3 groups of ewes included nutrients and metabolites (glucose, triglycerides, cholesterol, urea, creatinine, total protein, albumin, and bilirubin), enzymes (lactate dehydrogenase, aspartate transaminase, gamma-glutamyl transferase, alanine aminotransferase, and alkaline phosphatase [ALP]), and micronutrients (calcium, phosphorus, iron, sodium, potassium, and chloride). Sample chemistry values for glucose and total protein in pregnant ewes were lower than in follicular ewes; cholesterol was lower in pregnant and luteal ewes than in follicular ewes. In addition, total bilirubin in pregnant ewes differed from that in luteal ewes, and that in follicular ewes also differed from luteal ewes. ALP in pregnant ewes was higher than other groups; phosphorus in pregnant ewes was lower than in luteal ewes. Iron was higher in pregnant ewes than in luteal ewes, with iron in luteal ewes lower than in follicular ewes. These data provide clinical RIs comparing pregnant and non-pregnant ewes for use in monitoring ewe health in both human research and veterinary medicine.
Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.
Bell, Regan; Harr, Kendal; Rishniw, Mark; Pion, Paul
2014-06-01
While there have been ASVCP meeting discussions regarding quality assurance plans and lack thereof for in-clinic analyzers, there are little published data regarding in-clinic quality assurance and control practices. The purpose of this study was the identification of the common equipment used in hematologic, biochemical, urinalysis, and other testing, and assessment of quality control and assurance programs currently being performed in-clinic. All members of the Veterinary Information Network (VIN) were solicited to participate in an online survey between July and September 2007. In total, 452 complete or partial responses were received. Eighty-nine percent of respondents (361/404) said that veterinary technicians (unlicensed, licensed, and registered) performed the majority of analyses. Eighty-eight percent (366/417) of respondents performed some quality assurance on their laboratory equipment, most commonly on chemistry (91%, 324/357), and hematology (84%, 292/347) analyzers, and least commonly on fecal analyses (57%, 148/260) and ELISA assays (25%, 65/256). Ignorance of how to perform quality assurance was the most commonly stated reason (49%, 25/51) for lack of a quality assurance program. The majority of practices (316/374) utilized manufacturer-provided reference intervals without further adjustment or assessment. Roughly one-third of respondents (126/374) used reference intervals from textbooks, which is discouraged by ASVCP guidelines. This study found that the majority of respondents were not in compliance with ASVCP guidelines, illustrating the need for improved education of technical staff, veterinary students, and veterinarians regarding limitations of in-clinic laboratory equipment and the importance of regular quality control, maintenance, training, and reference interval development. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Schellenberg, François; Wielders, Jos; Anton, Raymond; Bianchi, Vincenza; Deenmamode, Jean; Weykamp, Cas; Whitfield, John; Jeppsson, Jan-Olof; Helander, Anders
2017-02-01
Carbohydrate-deficient transferrin (CDT) is used as a biomarker of sustained high alcohol consumption. The currently available measurement procedures for CDT are based on various analytical techniques (HPLC, capillary electrophoresis, nephelometry), some differing in the definition of the analyte and using different reference intervals and cut-off values. The Working Group on Standardization of CDT (WG-CDT), initiated by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), has validated an HPLC candidate reference measurement procedure (cRMP) for CDT (% disialotransferrin to total transferrin based on peak areas), demonstrating that it is suitable as a reference measurement procedure (RMP) for CDT. Presented is a detailed description of the cRMP and its calibration. Practical aspects on how to treat genetic variant and so-called di-tri bridge samples are described. Results of method performance characteristics, as demanded by ISO 15189 and ISO 15193, are given, as well as the reference interval and measurement uncertainty and how to deal with that in routine use. The correlation of the cRMP with commercial CDT procedures and the performance of the cRMP in a network of laboratories are also presented. The performance of the CDT cRMP in combination with previously developed commutable calibrators allows for standardization of the currently available commercial measurement procedures for CDT. The cRMP has recently been approved by the IFCC and will be from now on be known as the IFCC-RMP for CDT, while CDT results standardized according to this RMP should be indicated as CDT IFCC . Copyright © 2016 Elsevier B.V. All rights reserved.
Abou El Hassan, Mohamed; Stoianov, Alexandra; Araújo, Petra A T; Sadeghieh, Tara; Chan, Man Khun; Chen, Yunqi; Randell, Edward; Nieuwesteeg, Michelle; Adeli, Khosrow
2015-11-01
The CALIPER program has established a comprehensive database of pediatric reference intervals using largely the Abbott ARCHITECT biochemical assays. To expand clinical application of CALIPER reference standards, the present study is aimed at transferring CALIPER reference intervals from the Abbott ARCHITECT to Beckman Coulter AU assays. Transference of CALIPER reference intervals was performed based on the CLSI guidelines C28-A3 and EP9-A2. The new reference intervals were directly verified using up to 100 reference samples from the healthy CALIPER cohort. We found a strong correlation between Abbott ARCHITECT and Beckman Coulter AU biochemical assays, allowing the transference of the vast majority (94%; 30 out of 32 assays) of CALIPER reference intervals previously established using Abbott assays. Transferred reference intervals were, in general, similar to previously published CALIPER reference intervals, with some exceptions. Most of the transferred reference intervals were sex-specific and were verified using healthy reference samples from the CALIPER biobank based on CLSI criteria. It is important to note that the comparisons performed between the Abbott and Beckman Coulter assays make no assumptions as to assay accuracy or which system is more correct/accurate. The majority of CALIPER reference intervals were transferrable to Beckman Coulter AU assays, allowing the establishment of a new database of pediatric reference intervals. This further expands the utility of the CALIPER database to clinical laboratories using the AU assays; however, each laboratory should validate these intervals for their analytical platform and local population as recommended by the CLSI. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Saravanabhavan, Gurusankar; Werry, Kate; Walker, Mike; Haines, Douglas; Malowany, Morie; Khoury, Cheryl
2017-03-01
Human biomonitoring reference values are statistical estimates that indicate the upper margin of background exposure to a given chemical at a given time. Nationally representative human biomonitoring data on 176 chemicals, including several metals and trace elements, are available in Canada from 2007 to 2013 through the Canadian Health Measures Survey (CHMS). In this work, we used a systematic approach based on the reference interval concept proposed by the International Federation of Clinical Chemistry and Laboratory Medicine and the International Union of Pure and Applied Chemistry to derive reference values (RV 95 s) for metals and trace elements. These RV 95 s were derived for blood and urine matrices in the general Canadian population based on the latest biomonitoring data from the CHMS. Biomarkers were chosen based on specific selection criteria, including widespread detection in Canadians (≥66% detection rate). Reference populations were created for each biomarker by applying appropriate exclusion criteria. Age and sex were evaluated as possible partitioning criteria and separate RV 95 s were derived for the sub-populations in cases where partitioning was deemed necessary. The RV 95 s for metals and trace elements in blood ranged from 0.18μg/L for cadmium in young children aged 3-5 years to 7900μg/L for zinc in males aged 20-79 years. In the case of urinary biomarkers, the RV 95 s ranged from 0.17μg/L for antimony in the total population aged 3-79 years to 1400mg/L for fluoride in adults aged 20-79 years. These RV 95 s represent the first set of reference values for metals and trace elements in the general Canadian population. We compare the RV 95 s from other countries where available and discuss factors that could influence such comparisons. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.
ERIC Educational Resources Information Center
Krell, Moritz; Reinisch, Bianca; Krüger, Dirk
2015-01-01
In this study, secondary school students' (N?=?617; grades 7 to 10) understanding of models and modeling was assessed using tasks which explicitly refer to the scientific disciplines of biology, chemistry, and physics and, as a control, to no scientific discipline. The students' responses are interpreted as their biology-, chemistry-, and…
The theory of reference values: an unfinished symphony.
Siest, Gerard; Henny, Joseph; Gräsbeck, Ralph; Wilding, Peter; Petitclerc, Claude; Queraltó, Josep M; Hyltoft Petersen, Peter
2013-01-01
The history of the theory of reference values can be written as an unfinished symphony. The first movement, allegro con fuoco, played from 1960 to 1980: a mix of themes devoted to the study of biological variability (intra-, inter-individual, short- and long-term), preanalytical conditions, standardization of analytical methods, quality control, statistical tools for deriving reference limits, all of them complex variations developed on a central melody: the new concept of reference values that would replace the notion of normality whose definition was unclear. Additional contributions (multivariate reference values, use of reference limits from broad sets of patient data, drug interferences) conclude the movement on the variability of laboratory tests. The second movement, adagio, from 1980 to 2000, slowly develops and implements initial works. International and national recommendations were published by the IFCC-LM (International Federation of Clinical Chemistry and Laboratory Medicine) and scientific societies [French (SFBC), Spanish (SEQC), Scandinavian societies…]. Reference values are now topics of many textbooks and of several congresses, workshops, and round tables that are organized all over the world. Nowadays, reference values are part of current practice in all clinical laboratories, but not without difficulties, particularly for some laboratories to produce their own reference values and the unsuitability of the concept with respect to new technologies such as HPLC, GCMS, and PCR assays. Clinicians through consensus groups and practice guidelines have introduced their own tools, the decision limits, likelihood ratios and Reference Change Value (RCV), creating confusion among laboratorians and clinicians in substituting reference values and decision limits in laboratory reports. The rapid development of personalized medicine will eventually call for the use of individual reference values. The beginning of the second millennium is played allegro ma non-troppo from 2000 to 2012: the theory of reference values is back into fashion. The need to revise the concept is emerging. The manufacturers make a friendly pressure to facilitate the integration of Reference Intervals (RIs) in their technical documentation. Laboratorians are anxiously awaiting the solutions for what to do. The IFCC-LM creates Reference Intervals and Decision Limits Committee (C-RIDL) in 2005. Simultaneously, a joint working group IFCC-CLSI is created on the same topic. In 2008 the initial recommendations of IFCC-LM are revised and new guidelines are published by the Clinical and Laboratory Standards Institute (CLSI C28-A3). Fundamentals of the theory of reference values are not changed, but new avenues are explored: RIs transference, multicenter reference intervals, and a robust method for deriving RIs from small number of subjects. Concomitantly, other statistical methods are published such as bootstraps calculation and partitioning procedures. An alternative to recruiting healthy subjects proposes the use of biobanks conditional to the availability of controlled preanalytical conditions and of bioclinical data. The scope is also widening to include veterinary biology! During the early 2000s, several groups proposed the concept of 'Universal RIs' or 'Global RIs'. Still controversial, their applications await further investigations. The fourth movement, finale: beyond the methodological issues (statistical and analytical essentially), important questions remain unanswered. Do RIs intervene appropriately in medical decision-making? Are RIs really useful to the clinicians? Are evidence-based decision limits more appropriate? It should be appreciated that many laboratory tests represent a continuum that weakens the relevance of RIs. In addition, the boundaries between healthy and pathological states are shady areas influenced by many biological factors. In such a case the use of a single threshold is questionable. Wherever it will apply, individual reference values and reference change values have their place. A variation on an old theme! It is strange that in the period of personalized medicine (that is more stratified medicine), the concept of reference values which is based on stratification of homogeneous subgroups of healthy people could not be discussed and developed in conjunction with the stratification of sick patients. That is our message for the celebration of the 50th anniversary of Clinical Chemistry and Laboratory Medicine. Prospects are broad, enthusiasm is not lacking: much remains to be done, good luck for the new generations!
Establishment of new complete blood count reference values for healthy Thai adults.
Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O
2018-04-28
Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.
Logic, History, and the Chemistry Textbook: I. Does Chemistry Have a Logical Structure?
ERIC Educational Resources Information Center
Jensen, William B.
1998-01-01
Presents the first of three invited keynote lectures from the 1995 conference of the New England Association of Chemistry Teachers. Discusses the relevance of the history of chemistry to the teaching of chemistry. Contains 27 references. (DDR)
Uptake of recommended common reference intervals for chemical pathology in Australia.
Jones, Graham Rd; Koetsier, Sabrina
2017-05-01
Background Reference intervals are a vital part of reporting numerical pathology results. It is known, however, that variation in reference intervals between laboratories is common, even when analytical methods support common reference intervals. In response to this, in Australia, the Australasian Association of Clinical Biochemists together with the Royal College of Pathologists of Australasia published in 2014 a set of recommended common reference intervals for 11 common serum analytes (sodium, potassium, chloride, bicarbonate, creatinine male, creatinine female, calcium, calcium adjusted for albumin, phosphate, magnesium, lactate dehydrogenase, alkaline phosphatase and total protein). Methods Uptake of recommended common reference intervals in Australian laboratories was assessed using data from four annual cycles of the RCPAQAP reference intervals external quality assurance programme. Results Over three years, from 2013 to 2016, the use of the recommended upper and lower reference limits has increased from 40% to 83%. Nearly half of the intervals in use by enrolled laboratories in 2016 have been changed in this time period, indicating an active response to the guidelines. Conclusions These data support the activities of the Australasian Association of Clinical Biochemists and Royal College of Pathologists of Australasia in demonstrating a change in laboratory behaviour to reduce unnecessary variation in reference intervals and thus provide a consistent message to doctor and patients irrespective of the laboratory used.
Haematology and plasma chemistry of the red top ice blue mbuna cichlid (Metriaclima greshakei).
Snellgrove, Donna L; Alexander, Lucille G
2011-10-01
Clinical haematology and blood plasma chemistry can be used as a valuable tool to provide substantial diagnostic information for fish. A wide range of parameters can be used to assess nutritional status, digestive function, disease identification, routine metabolic levels, general physiological status and even the assessment and management of wild fish populations. However to evaluate such data accurately, baseline reference intervals for each measurable parameter must be established for the species of fish in question. Baseline data for ornamental fish species are limited, as research is more commonly conducted using commercially cultured fish. Blood samples were collected from sixteen red top ice blue cichlids (Metriaclima greshakei), an ornamental freshwater fish, to describe a range of haematology and plasma chemistry parameters. Since this cichlid is fairly large in comparison with most tropical ornamental fish, two independent blood samples were taken to assess a large range of parameters. No significant differences were noted between sample periods for any parameter. Values obtained for a large number of parameters were similar to those established for other closely related fish species such as tilapia (Oreochromis spp.). In addition to reporting the first set of blood values for M. Greshakei, to our knowledge, this study highlights the possibility of using previously established data for cultured cichlid species in studies with ornamental cichlid fish.
Cusack, Lara; Field, Cara L; Hoopes, Lisa; McDermott, Alexa; Clauss, Tonya
2016-06-01
Though one of the most widely kept elasmobranchs in human care, the cownose ray (CNR; Rhinoptera bonasus ), remains a species with minimal published information on hematologic reference intervals. As part of a larger study investigating the health and nutrition of the CNR, this study established a preliminary data set of plasma chemistry and hematology values specific to animals recently caught from the wild and compared this data set (intake sample) to values obtained following a period of quarantine (27-40 days) in an aquarium (exit sample). Blood samples were collected from 47 wild female (n = 46) and male (n = 1) CNR caught in pound nets off the coast of North Carolina and South Carolina. Differences between intake and exit values were analyzed. Due to the preponderance of female animals, data were not analyzed for sex differences. Plasma biochemical profiles were performed and analyzed. A select number of complete blood cell counts were performed (n = 24 from 12 animals). Statistically significant differences (P < 0.05) specific to time of sampling were determined for packed cell volume, total solids, blood urea nitrogen, sodium, chloride, potassium, phosphorus, cholesterol, glucose, and aspartate aminotransferase. Values reported are a significant expansion on the existing limited data for CNRs and will serve as a reference for health assessment of individuals both in the wild and in exhibit populations.
Zhang, Chuanbao; Guo, Wei; Huang, Hengjian; Ma, Yueyun; Zhuang, Junhua; Zhang, Jie
2013-01-01
Background Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. Methods A total of 3210 individuals (20–79 years) were enrolled in six representative geographical regions in China. Analytes of ALT, AST, GGT, ALP, total protein, albumin and total bilirubin were measured using three analytical systems mainly used in China. The newly established reference intervals were based on the results of traceability or multiple systems, and then validated in 21 large hospitals located nationwide qualified by the National External Quality Assessment (EQA) of China. Results We had been established reference intervals of the seven liver function tests for the Chinese adult population and found there were apparent variances of reference values for the variables for partitioning analysis such as gender(ALT, GGT, total bilirubin), age(ALP, albumin) and region(total protein). More than 86% of the 21 laboratories passed the validation in all subgroup of reference intervals and overall about 95.3% to 98.8% of the 1220 validation results fell within the range of the new reference interval for all liver function tests. In comparison with the currently recommended reference intervals in China, the single side observed proportions of out of range of reference values from our study for most of the tests deviated significantly from the nominal 2.5% such as total bilirubin (15.2%), ALP (0.2%), albumin (0.0%). Most of reference intervals in our study were obviously different from that of other races. Conclusion These used reference intervals are no longer applicable for the current Chinese population. We have established common reference intervals of liver function tests that are defined specifically for Chinese population and can be universally used among EQA-approved laboratories located all over China. PMID:24058449
NASA Astrophysics Data System (ADS)
Thakkar, Ajit J.
2017-09-01
This book provides non-specialists with a basic understanding of the underlying concepts of quantum chemistry. It is both a text for second- or third-year undergraduates and a reference for researchers who need a quick introduction or refresher. All chemists and many biochemists, materials scientists, engineers, and physicists routinely use spectroscopic measurements and electronic structure computations in their work. The emphasis of Quantum Chemistry on explaining ideas rather than enumerating facts or presenting procedural details makes this an excellent foundation text/reference.
Techniques in Chemistry: The Centerpiece of a Research-Oriented Curriculum.
ERIC Educational Resources Information Center
Hanks, T. W.; Wright, Laura L.
2002-01-01
Introduces the Techniques in Chemistry I course taught in the Furman University Department of Chemistry which focuses on organic and inorganic chemistry. Uses a problem solving approach and active learning. (Contains 17 references.) (YDS)
Ichihara, Kiyoshi; Ceriotti, Ferruccio; Tam, Tran Huu; Sueyoshi, Shigeo; Poon, Priscilla M K; Thong, Mee Ling; Higashiuesato, Yasushi; Wang, Xuejing; Kataoka, Hiromi; Matsubara, Akemi; Shiesh, Shu-Chu; Muliaty, Dewi; Kim, Jeong-Ho; Watanabe, Masakazu; Lam, Christopher W K; Siekmann, Lothar; Lopez, Joseph B; Panteghini, Mauro
2013-07-01
A multicenter study conducted in Southeast Asia to derive reference intervals (RIs) for 72 commonly measured analytes (general chemistry, inflammatory markers, hormones, etc.) featured centralized measurement to clearly detect regionality in test results. The results of 31 standardized analytes are reported, with the remaining analytes presented in the next report. The study included 63 clinical laboratories from South Korea, China, Vietnam, Malaysia, Indonesia, and seven areas in Japan. A total of 3541 healthy individuals aged 20-65 years (Japan 2082, others 1459) were recruited mostly from hospital workers using a well-defined common protocol. All serum specimens were transported to Tokyo at -80°C and collectively measured using reagents from four manufacturers. Three-level nested ANOVA was used to quantitate variation (SD) of test results due to region, sex, and age. A ratio of SD for a given factor over residual SD (representing net between-individual variations) (SDR) exceeding 0.3 was considered significant. Traceability of RIs was ensured by recalibration using value-assigned reference materials. RIs were derived parametrically. SDRs for sex and age were significant for 19 and 16 analytes, respectively. Regional difference was significant for 11 analytes, including high density lipoprotein (HDL)-cholesterol and inflammatory markers. However, when the data were limited to those from Japan, regionality was not observed in any of the analytes. Accordingly, RIs were derived with or without partition by sex and region. RIs applicable to a wide area in Asia were established for the majority of analytes with traceability to reference measuring systems, whereas regional partitioning was required for RIs of the other analytes.
Cerebrospinal fluid lactate and pyruvate concentrations and their ratio.
Zhang, Wan-Ming; Natowicz, Marvin R
2013-05-01
Determinations of cerebrospinal fluid (CSF) lactate and pyruvate concentrations and CSF lactate:pyruvate (L/P) ratios are important in several clinical settings, yet published normative data have significant limitations. We sought to determine a large dataset of stringently-defined normative data for CSF lactate and pyruvate concentrations and CSF L/P ratios. We evaluated data from 627 patients who had determinations of CSF lactate and/or CSF pyruvate from 2001 to 2011 at the Cleveland Clinic. Inclusion in the normal reference population required normal CSF cell counts, glucose and protein and routine serum chemistries and absence of progressive brain disorder, epilepsy, or seizure within 24h. Brain MRI, if done, showed no evidence of tumor, acute changes or basal ganglia abnormality. CSF cytology, CSF alanine and immunoglobulin levels, and oligoclonal band analysis were required to be normal, if done. Various inclusion/exclusion criteria were compared. 92 patients fulfilled inclusion/exclusion criteria for a reference population. The 95% central intervals (2.5%-97.5%) for CSF lactate and pyruvate levels were 1.01-2.09mM and 0.03-0.15mM, respectively, and 9.05-26.37 for CSF L/P. There were no significant gender-related differences of CSF lactate or pyruvate concentrations or of CSF L/P. Weak positive correlations between the concentration of CSF lactate or pyruvate and age were noted. Using stringent inclusion/exclusion criteria, we determined normative data for CSF lactate and pyruvate concentrations and CSF L/P ratios in a large, well-characterized reference population. Normalcy of routine CSF and blood analytes are the most important parameters in determining reference intervals for CSF lactate and pyruvate. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Hematology and serum chemistry reference ranges of free-ranging moose (Alces alces) in Norway.
Rostal, Melinda K; Evans, Alina L; Solberg, Erling J; Arnemo, Jon M
2012-07-01
Baseline reference ranges of serum chemistry and hematology data can be important indicators for the status of both individuals or populations of wild animals that are affected by emerging pathogens, toxicants, or other causes of disease. Frequently, reference ranges for these values are not available for wildlife species or subspecies. We present hematologic and serum chemistry reference ranges for moose (Alces alces) adults, yearlings, and calves in Norway sampled from 1992-2000. Additionally, we demonstrated that both induction time and chase time were correlated with initial rectal temperature, although they were not significantly correlated with cortisol, aspartate aminotransferase, glucose, or creatine kinase. Overall, the reference ranges given here are similar to those given for American moose, with a few differences that can be attributed to environment, testing methodology, or subspecies or species status. This is the first report, to our knowledge, of reference ranges for moose in Norway.
Serum TSH reference interval in healthy Finnish adults using the Abbott Architect 2000i Analyzer.
Schalin-Jäntti, Camilla; Tanner, Pirjo; Välimäki, Matti J; Hämäläinen, Esa
2011-07-01
Current serum TSH reference intervals have been criticized as they were established from unselected background populations. A special concern is that the upper limit, which defines subclinical hypothyroidism, is too high. The objective was to redefine the TSH reference interval in the adult Finnish population. The current reference interval for the widely used Abbott Architect method in Finland is 0.4-4.0 mU/L. Serum TSH and free T4 concentrations were derived from 606 healthy, non-pregnant, 18-91-year-old Finns from the Nordic Reference Interval Project (NORIP) and the possible effects of age, sex and thyroid peroxidase antibody (TPOAb) status were evaluated. After excluding TPOAb-positive subjects and outliers, a reference population of 511 subjects was obtained. In the reference population, no statistically significant gender- or age-specific differences in mean TSH (1.55 ± 3.30 mU/L) or TSH reference intervals were observed. The new reference interval was 0.5-3.6 mU/L (2.5th-97.5th percentiles). The current upper TSH reference limit is 10% too high. A TSH > 3.6 mU/L, confirmed with a repeat TSH sampling, may indicate subclinical hypothyroidism. Differences in ethnicity, regional iodine-intake and analytical methods underline the need for redefining the TSH reference interval in central laboratories in different countries.
Al-Mawali, Adhra; Pinto, Avinash Daniel; Al-Busaidi, Raiya; Al-Lawati, Rabab H; Morsi, Magdi
2018-01-01
Reference intervals for venous blood parameters differs with age, gender, geographic region, and ethnic groups. Hence local laboratory reference intervals are important to improve the diagnostic accuracy of health assessments and diseases. However, there have been no comprehensive published reference intervals established in Oman, the Gulf Cooperation Council or Middle Eastern countries. Hence, the aim of this study was to establish reference intervals for full blood count in healthy Omani adults. Venous blood specimens were collected from 2202 healthy individuals aged 18 to 69 years from January 2012 to April 2017, and analysed by Sysmex XS-1000i and Cell-Dyn Sapphire automated haematology analysers. Results were statistically analysed and compared by gender, age, and ABO blood group. The lower and upper reference limits of the haematology reference intervals were established at the 2.5th and 97.5th percentiles respectively. Reference intervals were calculated for 17 haematology parameters which included red blood cell, white blood cell, and platelet parameters. Red blood cell (RBC), haemoglobin (HGB), haematocrit (HCT), platelet and platelet haematocrit counts of the healthy donors were significantly different between males and females at all ages (p < 0.05), with males having higher mean values of RBC, HGB and HCT than females. Other complete blood count parameters showed no significant differences between genders, age groups, instruments, or blood groups. Our study showed a lower haemoglobin limit for the normal reference interval in males and females than the currently used in Oman. Data from this study established specific reference intervals which could be considered for general use in Oman. The differences in haematology reference intervals highlights the necessity to establish reference intervals for venous blood parameters among the healthy population in each country or at least in each region.
Perri, Amanda M.; O’Sullivan, Terri L.; Harding, John C.S.; Wood, R. Darren; Friendship, Robert M.
2017-01-01
The evaluation of pig hematology and biochemistry parameters is rarely done largely due to the costs associated with laboratory testing and labor, and the limited availability of reference intervals needed for interpretation. Within-herd and between-herd biological variation of these values also make it difficult to establish reference intervals. Regardless, baseline reference intervals are important to aid veterinarians in the interpretation of blood parameters for the diagnosis and treatment of diseased swine. The objective of this research was to provide reference intervals for hematology and biochemistry parameters of 3-week-old commercial nursing piglets in Ontario. A total of 1032 pigs lacking clinical signs of disease from 20 swine farms were sampled for hematology and iron panel evaluation, with biochemistry analysis performed on a subset of 189 randomly selected pigs. The 95% reference interval, mean, median, range, and 90% confidence intervals were calculated for each parameter. PMID:28373729
Chemistry in the Comics: Part 2. Classic Chemistry.
ERIC Educational Resources Information Center
Carter, Henry A.
1989-01-01
Describes topics in chemistry as related in the Classics Illustrated publications. Provides a list from "The Pioneers of Science" series with issue date, number, and biograhical topic. Lists references to topics in chemistry. Presents many pages from these comics. (MVL)
Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming
2016-12-12
BACKGROUND The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. MATERIAL AND METHODS Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. RESULTS We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31-7.89 ng/ml (males) and 1.01-7.10 ng/ml (females); CEA, 0.51-4.86 ng/ml (males) and 0.35-3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). CONCLUSIONS Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups.
The use of reference change values in clinical laboratories.
Bugdayci, Guler; Oguzman, Hamdi; Arattan, Havva Yasemin; Sasmaz, Guler
2015-01-01
The use of Reference Change Values (RCV) has been advocated as very useful for monitoring individuals. Most of these are performed for monitoring individuals in acute situations and for following up the improvement or deterioration of chronic diseases. In our study, we aimed at evaluating the RCV calculation for 24 clinical chemistry analytes widely used in clinical laboratories and the utilization of this data. Twenty-four serum samples were analyzed with Abbott kits (Abbott Laboratories, Abbott Park, IL, USA), manufactured for use with the Architect c8000 (Abbott Laboratories, Abbott Park, IL, USA) auto-analyzer. We calculated RCV using the following formula: RCV = Z x 2 1/2x (CVA2 + CVw2)1/2. Four reference change values (RCV) were calculated for each analyte using four statistical probabilities (0.95, and 0.99, unidirectional and bidirectional). Moreover, by providing an interval after identifying upper and lower limits with the Reference Change Factor (RCF), serially measured tests were calculated by using two formulas: exp (Z x 2 1/2 x (CV(A)2 + CVw2)½/100) for RCF(UP) and (1/RCF(UP)) for RCF(DOWN). RCVs of these analytes were calculated as 14.63% for glucose, 29.88% for urea, 17.75% for ALP, 53.39% for CK, 46.98% for CK-MB, 21.00% amylase, 8.00% for total protein, 8.70% for albumin, 51.08% for total bilirubin, 86.34% for direct bilirubin, 6.40% for calcium, 15.03% for creatinine, 21.47% for urate, 14.19% for total cholesterol, 46.62% for triglyceride, 20.51% for HDL-cholesterol, 29.59% for AST, 46.31% for ALT, 31.54% for GGT, 20.92% for LDH, 19.75% for inorganic phosphate, 3.05% for sodium, 11.75% for potassium, 4.44% for chloride (RCV, p < 0.05, unidirectionally). We suggest using RCV as well as using population-based reference intervals in clinical laboratories. RCV could be available as a tool for making clinical decision, especially when monitoring individuals.
Odhiambo, Collins; Oyaro, Boaz; Odipo, Richard; Otieno, Fredrick; Alemnji, George; Williamson, John; Zeh, Clement
2015-01-01
Important differences have been demonstrated in laboratory parameters from healthy persons in different geographical regions and populations, mostly driven by a combination of genetic, demographic, nutritional, and environmental factors. Despite this, European and North American derived laboratory reference intervals are used in African countries for patient management, clinical trial eligibility, and toxicity determination; which can result in misclassification of healthy persons as having laboratory abnormalities. An observational prospective cohort study known as the Kisumu Incidence Cohort Study (KICoS) was conducted to estimate the incidence of HIV seroconversion and identify determinants of successful recruitment and retention in preparation for an HIV vaccine/prevention trial among young adults and adolescents in western Kenya. Laboratory values generated from the KICoS were compared to published region-specific reference intervals and the 2004 NIH DAIDS toxicity tables used for the trial. About 1106 participants were screened for the KICoS between January 2007 and June 2010. Nine hundred and fifty-three participants aged 16 to 34 years, HIV-seronegative, clinically healthy, and non-pregnant were selected for this analysis. Median and 95% reference intervals were calculated for hematological and biochemistry parameters. When compared with both published region-specific reference values and the 2004 NIH DAIDS toxicity table, it was shown that the use of locally established reference intervals would have resulted in fewer participants classified as having abnormal hematological or biochemistry values compared to US derived reference intervals from DAIDS (10% classified as abnormal by local parameters vs. >40% by US DAIDS). Blood urea nitrogen was most often out of range if US based intervals were used: <10% abnormal by local intervals compared to >83% by US based reference intervals. Differences in reference intervals for hematological and biochemical parameters between western and African populations highlight importance of developing local reference intervals for clinical care and trials in Africa.
What is your diagnosis? Marked hyperchloremia in a dog.
Piperisova, Ida; Neel, Jennifer A; Papich, Mark G
2009-09-01
A 5-year-old neutered male Cavalier King Charles Spaniel was evaluated for a 3-week history of progressive paresis. The dog had been receiving potassium citrate capsules to acidify urine for the past 2 years because of an earlier history of urolithiasis. Results of neurologic examination, spinal cord radiography, and magnetic resonance imaging of the skull and spinal cord revealed no lesions that could have accounted for the neurologic signs. The main abnormalities on a clinical chemistry profile were marked hyperchloremia (179 mmol/L, reference interval 108-122 mmol/L) and an anion gap of -50.4 mmol/L (reference interval 16.3-28.6 mmol/L). Because of the severe hyperchloremia, serum bromide concentration was measured (400 mg/dL; toxic concentration >150 mg/dL; some dogs may tolerate up to 300 mg/dL). Analysis of the potassium citrate capsules, which had been compounded at a local pharmacy, yielded a mean bromide concentration of 239 mg/capsule. Administration of the capsules was discontinued and there was rapid resolution of the dog's neurologic signs. This case of extreme bromide toxicity, which apparently resulted from inadvertent use of bromide instead of citrate at the pharmacy, illustrates the importance of knowing common interferents with analyte methodologies and of pursing logical additional diagnostic tests based on clinical and laboratory evidence, even when a patient's history appears to rule out a potential etiology.
NASA Astrophysics Data System (ADS)
Zhang, Yunshen
2017-12-01
Coordination chemistry refers to a branch of chemistry, and its research results are widely used in industry and people's daily life. Many edge disciplines emerge during the development, which propels the process of disciplines and technology. This paper briefly discusses new progress of coordination chemistry and its application in chemistry and chemical industry in recent years.
Systematic review of serum steroid reference intervals developed using mass spectrometry.
Tavita, Nevada; Greaves, Ronda F
2017-12-01
The aim of this study was to perform a systematic review of the published literature to determine the available serum/plasma steroid reference intervals generated by mass spectrometry (MS) methods across all age groups in healthy subjects and to suggest recommendations to achieve common MS based reference intervals for serum steroids. MEDLINE, EMBASE and PubMed databases were used to conduct a comprehensive search for English language, MS-based reference interval studies for serum/plasma steroids. Selection of steroids to include was based on those listed in the Royal College of Pathologists of Australasia Quality Assurance Programs, Chemical Pathology, Endocrine Program. This methodology has been registered onto the PROSPERO International prospective register of systematic reviews (ID number: CRD42015029637). After accounting for duplicates, a total of 60 manuscripts were identified through the search strategy. Following critical evaluation, a total of 16 studies were selected. Of the 16 studies, 12 reported reference intervals for testosterone, 11 for 17 hydroxy-progesterone, nine for androstenedione, six for cortisol, three for progesterone, two for dihydrotestosterone and only one for aldosterone and dehydroepiandrosterone sulphate. No studies established MS-based reference intervals for oestradiol. As far as we are aware, this report provides the first comparison of the peer reviewed literature for serum/plasma steroid reference intervals generated by MS-based methods. The reference intervals based on these published studies can be used to inform the process to develop common reference intervals, and agreed reporting units for mass spectrometry based steroid methods. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).
Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu
2009-01-01
Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.
Writing in Chemistry: An Effective Learning Tool.
ERIC Educational Resources Information Center
Sherwood, Donna W.; Kovac, Jeffrey
1999-01-01
Presents some general strategies for using writing in chemistry courses based on experiences in developing a systematic approach to using writing as an effective learning tool in chemistry courses, and testing this approach in high-enrollment general chemistry courses at the University of Tennessee-Knoxville. Contains 18 references. (WRM)
Ceriotti, Ferruccio
2017-07-01
Reference intervals and decision limits are a critical part of the clinical laboratory report. The evaluation of their correct use represents a tool to verify the post analytical quality. Four elements are identified as indicators. 1. The use of decision limits for lipids and glycated hemoglobin. 2. The use, whenever possible, of common reference values. 3. The presence of gender-related reference intervals for at least the following common serum measurands (besides obviously the fertility relate hormones): alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), creatinine, gamma-glutamyl transferase (GGT), IgM, ferritin, iron, transferrin, urate, red blood cells (RBC), hemoglobin (Hb) and hematocrit (Hct). 4. The presence of age-related reference intervals. The problem of specific reference intervals for elderly people is discussed, but their use is not recommended; on the contrary it is necessary the presence of pediatric age-related reference intervals at least for the following common serum measurands: ALP, amylase, creatinine, inorganic phosphate, lactate dehydrogenase, aspartate aminotransferase, urate, insulin like growth factor 1, white blood cells, RBC, Hb, Hct, alfa-fetoprotein and fertility related hormones. The lack of such reference intervals may imply significant risks for the patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Suka, Machi; Yoshida, Katsumi; Kawai, Tadashi; Aoki, Yoshikazu; Yamane, Noriyuki; Yamauchi, Kuniaki
2005-07-01
To determine age- and sex-specific reference intervals for 10 health examination items in Japanese adults. Health examination data were accumulated from 24 different prefectural health service associations affiliated with the Japan Association of Health Service. Those who were non-smokers, drank less than 7 days/week, and had a body mass index of 18.5-24.9kg/m2 were sampled as a reference population (n = 737,538; 224,947 men and 512,591 women). After classified by age and sex, reference intervals for 10 health examination items (systolic blood pressure, diastolic blood pressure, total cholesterol, triglyceride, glucose, uric acid, AST, ALT, gamma-GT, and hemoglobin) were estimated using the parametric and nonparametric methods. In every item except for hemoglobin, men had higher reference intervals than women. Systolic blood pressure, total cholesterol, and glucose showed an upward trend in values with increasing age. Hemoglobin showed a downward trend in values with increasing age. Triglyceride, ALT, and gamma-GT reached a peak in middle age. Overall, parametric estimates showed narrower reference intervals than non-parametric estimates. Reference intervals vary with age and sex. Age- and sex-specific reference intervals may contribute to better assessment of health examination data.
Zhang, Gao-Ming; Guo, Xu-Xiao; Ma, Xiao-Bo; Zhang, Guo-Ming
2016-01-01
Background The aim of this study was to calculate 95% reference intervals and double-sided limits of serum alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) according to the CLSI EP28-A3 guideline. Material/Methods Serum AFP and CEA values were measured in samples from 26 000 healthy subjects in the Shuyang area receiving general health checkups. The 95% reference intervals and upper limits were calculated by using MedCalc. Results We provided continuous reference intervals from 20 years old to 90 years old for AFP and CEA. The reference intervals were: AFP, 1.31–7.89 ng/ml (males) and 1.01–7.10 ng/ml (females); CEA, 0.51–4.86 ng/ml (males) and 0.35–3.45ng/ml (females). AFP and CEA were significantly positively correlated with age in both males (r=0.196 and r=0.198) and females (r=0.121 and r=0.197). Conclusions Different races or populations and different detection systems may result in different reference intervals for AFP and CEA. Continuous reference intervals of age changes are more accurate than age groups. PMID:27941709
Miri-Dashe, Timzing; Osawe, Sophia; Tokdung, Monday; Daniel, Monday Tokdung Nenbammun; Daniel, Nenbammun; Choji, Rahila Pam; Mamman, Ille; Deme, Kurt; Damulak, Dapus; Abimiku, Alash'le
2014-01-01
Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women. Consented clients were clinically screened and counseled before testing for HIV, Hepatitis B, Hepatitis C and Syphilis. Standard national blood donors' questionnaire was administered to consented blood donors. Blood from qualified volunteers was used for measurement of complete hematology and chemistry parameters. Blood samples were analyzed from a total of 383 participants, 124 (32.4%) males, 125 (32.6%) non-pregnant females and 134 pregnant females (35.2%) with a mean age of 31 years. Our results showed that the red blood cells count (RBC), Hemoglobin (HB) and Hematocrit (HCT) had significant gender difference (p = 0.000) but not for total white blood count (p>0.05) which was only significantly higher in pregnant verses non-pregnant women (p = 0.000). Hemoglobin and Hematocrit values were lower in pregnancy (P = 0.000). Platelets were significantly higher in females than men (p = 0.001) but lower in pregnant women (p = .001) with marked difference in gestational period. For clinical chemistry parameters, there was no significant difference for sodium, potassium and chloride (p>0.05) but gender difference exists for Bicarbonate (HCO3), Urea nitrogen, Creatinine as well as the lipids (p<0.05). Total bilirubin was significantly higher in males than females (p = 0.000). Significant differences exist for all chemistry parameters between pregnant and non-pregnant women in this study (p<0.05), except Amylase and total cholesterol (p>0.05). Hematological and Clinical Chemistry reference ranges established in this study showed significant gender differences. Pregnant women also differed from non-pregnant females and during pregnancy. This is the first of such comprehensive study to establish reference values among adult Nigerians and difference observed underscore the need to establish reference values for different populations.
Interior. Balance room for chemistry laboratory. Storage room for glassware ...
Interior. Balance room for chemistry laboratory. Storage room for glassware and reference room with frequently used chemistry and chemical engineering texts. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
A Closer Look at Phase Diagrams for the General Chemistry Course.
ERIC Educational Resources Information Center
Gramsch, Stephen A.
2000-01-01
Information concerning structural chemistry and phase equilibria contained in the full phase diagrams of common substances is a great deal richer than the general chemistry students are given to believe. Discusses ways of enriching the traditional presentation of phase diagrams in general chemistry courses. (Contains over 20 references.) (WRM)
ESTABLISHMENT OF A FIBRINOGEN REFERENCE INTERVAL IN ORNATE BOX TURTLES (TERRAPENE ORNATA ORNATA).
Parkinson, Lily; Olea-Popelka, Francisco; Klaphake, Eric; Dadone, Liza; Johnston, Matthew
2016-09-01
This study sought to establish a reference interval for fibrinogen in healthy ornate box turtles ( Terrapene ornata ornata). A total of 48 turtles were enrolled, with 42 turtles deemed to be noninflammatory and thus fitting the inclusion criteria and utilized to estimate a fibrinogen reference interval. Turtles were excluded based upon physical examination and blood work abnormalities. A Shapiro-Wilk normality test indicated that the noninflammatory turtle fibrinogen values were normally distributed (Gaussian distribution) with an average of 108 mg/dl and a 95% confidence interval of the mean of 97.9-117 mg/dl. Those turtles excluded from the reference interval because of abnormalities affecting their health had significantly different fibrinogen values (P = 0.313). A reference interval for healthy ornate box turtles was calculated. Further investigation into the utility of fibrinogen measurement for clinical usage in ornate box turtles is warranted.
Analytical Chemistry: A Literary Approach
NASA Astrophysics Data System (ADS)
Lucy, Charles A.
2000-04-01
The benefits of incorporating real-world examples of chemistry into lectures and lessons is reflected by the recent inclusion of the Teaching with Problems and Case Studies column in this Journal. However, these examples lie outside the experience of many students, and so much of the impact of "real-world" examples is lost. This paper provides an anthology of references to analytical chemistry techniques from history, popular fiction, and film. Such references are amusing to both instructor and student. Further, the fictional descriptions can serve as a focal point for discussions of a technique's true capabilities and limitations.
ERIC Educational Resources Information Center
Kozma, Robert B.; Russell, Joel
1997-01-01
Examines how professional chemists and undergraduate chemistry students respond to chemistry-related video segments, graphs, animations, and equations. Discusses the role that surface features of representations play in the understanding of chemistry. Contains 36 references. (DDR)
van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W
2016-07-01
Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.
Wedemeyer, Gary A.; Nelson, Nancy C.
1975-01-01
Gaussian and nonparametric (percentile estimate and tolerance interval) statistical methods were used to estimate normal ranges for blood chemistry (bicarbonate, bilirubin, calcium, hematocrit, hemoglobin, magnesium, mean cell hemoglobin concentration, osmolality, inorganic phosphorus, and pH for juvenile rainbow (Salmo gairdneri, Shasta strain) trout held under defined environmental conditions. The percentile estimate and Gaussian methods gave similar normal ranges, whereas the tolerance interval method gave consistently wider ranges for all blood variables except hemoglobin. If the underlying frequency distribution is unknown, the percentile estimate procedure would be the method of choice.
Using Bad Science to Teach Good Chemistry.
ERIC Educational Resources Information Center
Epstein, Michael S.
1998-01-01
Describes the integration of topics dealing with "bad science"--pseudo, pathological, or deviant science--into introductory undergraduate courses in general and analytical chemistry, and provides extensive references for the chemistry instructor interested in these topics. The approach is to incorporate specific cases that address…
Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka
2015-01-01
To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.
Pediatric Reference Intervals for Free Thyroxine and Free Triiodothyronine
Jang, Megan; Guo, Tiedong; Soldin, Steven J.
2009-01-01
Background The clinical value of free thyroxine (FT4) and free triiodothyronine (FT3) analysis depends on the reference intervals with which they are compared. We determined age- and sex-specific reference intervals for neonates, infants, and children 0–18 years of age for FT4 and FT3 using tandem mass spectrometry. Methods Reference intervals were calculated for serum FT4 (n = 1426) and FT3 (n = 1107) obtained from healthy children between January 1, 2008, and June 30, 2008, from Children's National Medical Center and Georgetown University Medical Center Bioanalytical Core Laboratory, Washington, DC. Serum samples were analyzed using isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS) with deuterium-labeled internal standards. Results FT4 reference intervals were very similar for males and females of all ages and ranged between 1.3 and 2.4 ng/dL for children 1 to 18 years old. FT4 reference intervals for 1- to 12-month-old infants were 1.3–2.8 ng/dL. These 2.5 to 97.5 percentile intervals were much tighter than reference intervals obtained using immunoassay platforms 0.48–2.78 ng/dL for males and 0.85–2.09 ng/dL for females. Similarly, FT3 intervals were consistent and similar for males and females and for all ages, ranging between 1.5 pg/mL and approximately 6.0 pg/mL for children 1 month of age to 18 years old. Conclusions This is the first study to provide pediatric reference intervals of FT4 and FT3 for children from birth to 18 years of age using LC/MS/MS. Analysis using LC/MS/MS provides more specific quantification of thyroid hormones. A comparison of the ultrafiltration tandem mass spectrometric method with equilibrium dialysis showed very good correlation. PMID:19583487
Broughton, Heather M; Govender, Danny; Shikwambana, Purvance; Chappell, Patrick; Jolles, Anna
2017-06-01
The International Species Information System has set forth an extensive database of reference intervals for zoologic species, allowing veterinarians and game park officials to distinguish normal health parameters from underlying disease processes in captive wildlife. However, several recent studies comparing reference values from captive and free-ranging animals have found significant variation between populations, necessitating the development of separate reference intervals in free-ranging wildlife to aid in the interpretation of health data. Thus, this study characterizes reference intervals for six biochemical analytes, eleven hematologic or immune parameters, and three hormones using samples from 219 free-ranging African lions ( Panthera leo ) captured in Kruger National Park, South Africa. Using the original sample population, exclusion criteria based on physical examination were applied to yield a final reference population of 52 clinically normal lions. Reference intervals were then generated via 90% confidence intervals on log-transformed data using parametric bootstrapping techniques. In addition to the generation of reference intervals, linear mixed-effect models and generalized linear mixed-effect models were used to model associations of each focal parameter with the following independent variables: age, sex, and body condition score. Age and sex were statistically significant drivers for changes in hepatic enzymes, renal values, hematologic parameters, and leptin, a hormone related to body fat stores. Body condition was positively correlated with changes in monocyte counts. Given the large variation in reference values taken from captive versus free-ranging lions, it is our hope that this study will serve as a baseline for future clinical evaluations and biomedical research targeting free-ranging African lions.
Reference interval for thyrotropin in a ultrasonography screened Korean population
Kim, Mijin; Kim, Soo Han; Lee, Yunkyoung; Park, Su-yeon; Kim, Hyung-don; Kwon, Hyemi; Choi, Yun Mi; Jang, Eun Kyung; Jeon, Min Ji; Kim, Won Gu; Shong, Young Kee; Kim, Won Bae
2015-01-01
Background/Aims The diagnostic accuracy of thyroid dysfunctions is primarily affected by the validity of the reference interval for serum thyroid-stimulating hormone (TSH). Thus, the present study aimed to establish a reference interval for TSH using a normal Korean population. Methods This study included 19,465 subjects who were recruited after undergoing routine health check-ups. Subjects with overt thyroid disease, a prior history of thyroid disease, or a family history of thyroid cancer were excluded from the present analyses. The reference range for serum TSH was evaluated in a normal Korean reference population which was defined according to criteria based on the guidelines of the National Academy of Clinical Biochemistry, ultrasound (US) findings, and smoking status. Sex and age were also taken into consideration when evaluating the distribution of serum TSH levels in different groups. Results In the presence of positive anti-thyroid peroxidase antibodies or abnormal US findings, the central 95 percentile interval of the serum TSH levels was widened. Additionally, the distribution of serum TSH levels shifted toward lower values in the current smokers group. The reference interval for TSH obtained using a normal Korean reference population was 0.73 to 7.06 mIU/L. The serum TSH levels were higher in females than in males in all groups, and there were no age-dependent shifts. Conclusions The present findings demonstrate that the serum TSH reference interval in a normal Korean reference population was higher than that in other countries. This result suggests that the upper and lower limits of the TSH reference interval, which was previously defined by studies from Western countries, should be raised for Korean populations. PMID:25995664
Chemistry on the Go: Review of Chemistry Apps on Smartphones
ERIC Educational Resources Information Center
Libman, Diana; Huang, Ling
2013-01-01
touch-controlled computers such as smartphones and iPods are seeing dramatic growth with increasing adoption rates. This review covers about 30 popular and mostly free apps that can be used to learn chemistry and to serve as reference or research tools. The target…
Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.
Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W
2016-02-26
Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.
Oikonomidis, Ioannis L; Kiosis, Evangelos A; Brozos, Christos N; Kritsepi-Konstantinou, Maria G
2017-03-01
OBJECTIVE To establish reference intervals for serum reactive oxygen metabolites (ROMs), biological antioxidant potential (BAP), and oxidative stress index (OSi) in adult rams by use of controlled preanalytic and analytic procedures. ANIMALS 123 healthy 1- to 4-year-old rams of 2 Greek breeds (Chios [n = 62] and Florina [61]). PROCEDURES 4 hours after rams were fed, a blood sample was obtained from each ram, and serum was harvested. Concentrations of ROMs and BAP were measured colorimetrically on a spectrophotometric analyzer. The OSi was calculated as ROMs concentration divided by BAP concentration. Combined and breed-specific reference intervals were calculated by use of nonparametric and robust methods, respectively. Reference intervals were defined as the 2.5th to 97.5th percentiles. RESULTS Reference intervals for ROMs, BAP, and OSi for all rams combined were 65 to 109 Carratelli units, 2,364 to 4,491 μmol/L, and 18.2 to 43.0 Carratelli units/(mmol/L), respectively. Reference intervals of Chios rams for ROMs, BAP, and OSi were 56 to 113 Carratelli units, 2,234 to 4,290 μmol/L, and 12.9 to 38.4 Carratelli units/(mmol/L), respectively. Reference intervals of Florina rams for ROMs, BAP, and OSi were 68 to 111 Carratelli units, 2,337 to 4,363 μmol/L, and 14.1 to 38.1 Carratelli units/(mmol/L), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Reference intervals calculated in this study can be used as a guide for the interpretation of ROMs, BAP, and OSi results in rams and, under appropriate conditions, can be adopted for use by veterinary laboratories.
Bone turnover marker reference intervals in young females.
Callegari, Emma T; Gorelik, Alexandra; Garland, Suzanne M; Chiang, Cherie Y; Wark, John D
2017-07-01
Background The use of bone turnover markers in clinical practice and research in younger people is limited by the lack of normative data and understanding of common causes of variation in bone turnover marker values in this demographic. To appropriately interpret bone turnover markers, robust reference intervals specific to age, development and sex are necessary. This study aimed to determine reference intervals of bone turnover markers in females aged 16-25 years participating in the Safe-D study. Methods Participants were recruited through social networking site Facebook and were asked to complete an extensive, online questionnaire and attend a site visit. Participants were tested for serum carboxy-terminal cross-linking telopeptide of type 1 collagen and total procollagen type 1 N-propeptide using the Roche Elecsys automated analyser. Reference intervals were determined using the 2.5th to 97.5th percentiles of normalized bone turnover marker values. Results Of 406 participants, 149 were excluded due to medical conditions or medication use (except hormonal contraception) which may affect bone metabolism. In the remaining 257 participants, the reference interval was 230-1000 ng/L for serum carboxy-terminal cross-linking telopeptide of type 1 collagen and 27-131 µg/L for procollagen type 1 N-propeptide. Both marker concentrations were inversely correlated with age and oral contraceptive pill use. Therefore, intervals specific to these variables were calculated. Conclusions We defined robust reference intervals for cross-linking telopeptide of type 1 collagen and procollagen type 1 N-propeptide in young females grouped by age and contraceptive pill use. We examined bone turnover markers' relationship with several lifestyle, clinical and demographic factors. Our normative intervals should aid interpretation of bone turnover markers in young females particularly in those aged 16 to 19 years where reference intervals are currently provisional.
Lunar igneous rocks and the nature of the lunar interior
NASA Technical Reports Server (NTRS)
Hays, J. F.; Walker, D.
1974-01-01
Lunar igneous rocks are interpreted, which can give useful information about mineral assemblages and mineral chemistry as a function of depth in the lunar interior. Terra rocks, though intensely brecciated, reveal, in their chemistry, evidence for a magmatic history. Partial melting of feldspathic lunar crustal material occurred in the interval 4.6 to 3.9 gy. Melting of ilmenite-bearing cumulates at depths near 100 km produced parent magmas for Apollo 11 and 17 titaniferous mare basalts in the interval 3.8 to 3.6 gy. Melting of ilmenite-free olivine pyroxenites at depths greater than 200 km produced low-titanium mare basalts in the interval 3.4 to 3.1 gy. No younger igneous rocks have yet been recognized among the lunar samples and present-day melting seems to be limited to depths greater than 1000 km.
Lunar igneous rocks and the nature of the lunar interior
NASA Technical Reports Server (NTRS)
Hays, J. F.; Walker, D.
1977-01-01
Lunar igneous rocks, properly interpreted, can give useful information about mineral assemblages and mineral chemistry as a function of depth in the lunar interior. Though intensely brecciated, terra rocks reveal, in their chemistry, evidence for a magmatic history. Partial melting of feldspathic lunar crustal material occurred in the interval 4.6 to 3.9 Gy. Melting of ilmenite-bearing cumulates at depths near 100 km produced parent magmas for Apollo 11 and 17 titaniferous mare basalts in the interval 3.8 to 3.6 Gy. Melting of ilmenite-free olivine pyroxenites (also cumulates?) at depths greater than 200 km produced low-titanium mare basalts in the interval 3.4 to 3.1 Gy. No younger igneous rocks have yet been recognized among the lunar samples and present-day melting seems to be limited to depths greater than 1000 km.
Wilmoth, Siri K.; Irvine, Kathryn M.; Larson, Chad
2015-01-01
Various GIS-generated land-use predictor variables, physical habitat metrics, and water chemistry variables from 75 reference streams and 351 randomly sampled sites throughout Washington State were evaluated for effectiveness at discriminating reference from random sites within level III ecoregions. A combination of multivariate clustering and ordination techniques were used. We describe average observed conditions for a subset of predictor variables as well as proposing statistical criteria for establishing reference conditions for stream habitat in Washington. Using these criteria, we determined whether any of the random sites met expectations for reference condition and whether any of the established reference sites failed to meet expectations for reference condition. Establishing these criteria will set a benchmark from which future data will be compared.
Blood gases, biochemistry and haematology of Galápagos hawksbill turtles (Eretmochelys imbricata)
Muñoz-Pérez, Juan Pablo; Hirschfeld, Maximilian; Alarcón-Ruales, Daniela; Denkinger, Judith; Castañeda, Jason Guillermo; García, Juan; Lohmann, Kenneth J.
2017-01-01
Abstract The hawksbill turtle, Eretmochelys imbricata, is a marine chelonian with a circum-global distribution, but the species is critically endangered and has nearly vanished from the eastern Pacific. Although reference blood parameter intervals have been published for many chelonian species and populations, including nesting Atlantic hawksbills, no such baseline biochemical and blood gas values have been reported for wild Pacific hawksbill turtles. Blood samples were drawn from eight hawksbill turtles captured in near shore foraging locations within the Galápagos archipelago over a period of four sequential years; three of these turtles were recaptured and sampled on multiple occasions. Of the eight sea turtles sampled, five were immature and of unknown sex, and the other three were females. A portable blood analyzer was used to obtain near immediate field results for a suite of blood gas and chemistry parameters. Values affected by temperature were corrected in two ways: (i) with standard formulas and (ii) with auto-corrections made by the portable analyzer. A bench top blood chemistry analyzer was used to measure a series of biochemistry parameters from plasma. Standard laboratory haematology techniques were employed for red and white blood cell counts and to determine haematocrit manually, which was compared to the haematocrit values generated by the portable analyzer. The values reported in this study provide reference data that may be useful in comparisons among populations and in detecting changes in health status among Galápagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease or environmental disasters. PMID:28496982
Blood gases, biochemistry and haematology of Galápagos hawksbill turtles (Eretmochelys imbricata).
Muñoz-Pérez, Juan Pablo; Lewbart, Gregory A; Hirschfeld, Maximilian; Alarcón-Ruales, Daniela; Denkinger, Judith; Castañeda, Jason Guillermo; García, Juan; Lohmann, Kenneth J
2017-01-01
The hawksbill turtle, Eretmochelys imbricata , is a marine chelonian with a circum-global distribution, but the species is critically endangered and has nearly vanished from the eastern Pacific. Although reference blood parameter intervals have been published for many chelonian species and populations, including nesting Atlantic hawksbills, no such baseline biochemical and blood gas values have been reported for wild Pacific hawksbill turtles. Blood samples were drawn from eight hawksbill turtles captured in near shore foraging locations within the Galápagos archipelago over a period of four sequential years; three of these turtles were recaptured and sampled on multiple occasions. Of the eight sea turtles sampled, five were immature and of unknown sex, and the other three were females. A portable blood analyzer was used to obtain near immediate field results for a suite of blood gas and chemistry parameters. Values affected by temperature were corrected in two ways: (i) with standard formulas and (ii) with auto-corrections made by the portable analyzer. A bench top blood chemistry analyzer was used to measure a series of biochemistry parameters from plasma. Standard laboratory haematology techniques were employed for red and white blood cell counts and to determine haematocrit manually, which was compared to the haematocrit values generated by the portable analyzer. The values reported in this study provide reference data that may be useful in comparisons among populations and in detecting changes in health status among Galápagos sea turtles. The findings might also be helpful in future efforts to demonstrate associations between specific biochemical parameters and disease or environmental disasters.
A Comparison Study: Assessing Teachers' Conceptions with the Chemistry Concepts Inventory
ERIC Educational Resources Information Center
Kruse, Rebecca A.; Roehrig, Gillian H.
2005-01-01
The conceptions of chemistry teachers with diverse backgrounds within a large urban district are assessed. The Chemistry Concepts Inventory (CCI) and Mulford and Robinson's research study were utilized for reference and conceptual factors contributing to teachers' conceptions such as degree major and credential status were analyzed from data…
A Novel High School Chemistry Camp as an Outreach Model for Regional Colleges and Universities.
ERIC Educational Resources Information Center
Exstrom, Christopher L.; Mosher, Michael D.
2000-01-01
Describes the summer chemistry camp offered by the University of Nebraska at Kearney which consists of multistage open-ended laboratory projects. Focuses on introducing high school students to principles, methods, and equipment used in academic and professional chemistry laboratories. (Contains 19 references.) (YDS)
High-School Chemistry Teaching through Environmentally Oriented Curricula
ERIC Educational Resources Information Center
Mandler, Daphna; Mamlok-Naaman, Rachel; Blonder, Ron; Yayon, Malka; Hofstein, Avi
2012-01-01
Discussions held in the chemical education community have generated a variety of reports and recommendations for reforming the chemistry curriculum. The recommendations refer to teaching chemistry in the context of real-world issues. This has been suggested as a way to enhance students' motivation. It is suggested that real-world problems…
Teaching Chemistry Using the Movie "Apollo 13."
ERIC Educational Resources Information Center
Goll, James G.; Woods, B. J.
1999-01-01
Offers suggestions for incorporating topics that relate to the Apollo 13 space mission into a chemistry course. Discusses connections between the study of chemistry and space exploration, including fuels and oxidants used, reasons for an oxygen tank rupture, and lithium hydroxide-containing carbon dioxide filters. Contains 11 references. (WRM)
Proportional Reasoning in the Learning of Chemistry: Levels of Complexity
ERIC Educational Resources Information Center
Ramful, Ajay; Narod, Fawzia Bibi
2014-01-01
This interdisciplinary study sketches the ways in which proportional reasoning is involved in the solution of chemistry problems, more specifically, problems involving quantities in chemical reactions (commonly referred to as stoichiometry problems). By building on the expertise of both mathematics and chemistry education research, the present…
ERIC Educational Resources Information Center
Susianna, Nancy
2011-01-01
The objectives of this research were to identify the characteristics and effectiveness of chemistry teaching programs that increase students' entrepreneurial attitudes, chemistry concepts understanding and creativity. The research design application refers to the R & D (Research and Development) Design. Seventy-three senior high school students…
ERIC Educational Resources Information Center
Tsaparlis, Georgios
2014-01-01
Jensen's scheme for the logical structure of chemistry is taken as reference to study the logical structure of physical chemistry. The scheme distinguishes three dimensions (composition and structure, energy, and time), with each dimension treated at one of the three levels (molar, molecular, and electrical). Such a structure places the outer…
Sparky IntroChem: A Student-Oriented Introductory Chemistry Course.
ERIC Educational Resources Information Center
Butcher, David J.; Brandt, Paul F.; Norgaard, Nicholas J.; Atterholt, Cynthia A.; Salido, Arthur L.
2003-01-01
Describes an introductory chemistry course that incorporates student-oriented approaches such as inquiry and problem-based laboratories. Provides an overview of the modules. (Contains 16 references.) (DDR)
Christopher, Mary M.; Berry, Kristin H.; Wallis, I.R.; Nagy, K.A.; Henen, B.T.; Peterson, C.C.
1999-01-01
Desert tortoise (Gopherus agassizii) populations have experienced precipitous declines resulting from the cumulative impact of habitat loss, and human and disease-related mortality. Evaluation of hematologic and biochemical responses of desert tortoises to physiologic and environmental factors can facilitate the assessment of stress and disease in tortoises and contribute to management decisions and population recovery. The goal of this study was to obtain and analyze clinical laboratory data from free-ranging desert tortoises at three sites in the Mojave Desert (California, USA) between October 1990 and October 1995, to establish reference intervals, and to develop guidelines for the interpretation of laboratory data under a variety of environmental and physiologic conditions. Body weight, carapace length, and venous blood samples for a complete blood count and clinical chemistry profile were obtained from 98 clinically healthy adult desert tortoises of both sexes at the Desert Tortoise Research Natural area (western Mojave), Goffs (eastern Mojave) and Ivanpah Valley (northeastern Mojave). Samples were obtained four times per year, in winter (February/March), spring (May/June), summer (July/August), and fall (October). Years of near-, above- and below-average rainfall were represented in the 5 yr period. Minimum, maximum and median values, and central 95 percentiles were used as reference intervals and measures of central tendency for tortoises at each site and/or season. Data were analyzed using repeated measures analysis of variance for significant (P < 0.01) variation on the basis of sex, site, season, and interactions between these variables. Significant sex differences were observed for packed cell volume, hemoglobin concentration, aspartate transaminase activity, and cholesterol, triglyceride, calcium, and phosphorus concentrations. Marked seasonal variation was observed in most parameters in conjunction with reproductive cycle, hibernation, or seasonal rainfall. Year-to-year differences and long-term alterations primarily reflected winter rainfall amounts. Site differences were minimal, and largely reflected geographic differences in precipitation patterns, such that results from these studies can be applied to other tortoise populations in environments with known rainfall and forage availability patterns.
Daly, Caitlin H; Higgins, Victoria; Adeli, Khosrow; Grey, Vijay L; Hamid, Jemila S
2017-12-01
To statistically compare and evaluate commonly used methods of estimating reference intervals and to determine which method is best based on characteristics of the distribution of various data sets. Three approaches for estimating reference intervals, i.e. parametric, non-parametric, and robust, were compared with simulated Gaussian and non-Gaussian data. The hierarchy of the performances of each method was examined based on bias and measures of precision. The findings of the simulation study were illustrated through real data sets. In all Gaussian scenarios, the parametric approach provided the least biased and most precise estimates. In non-Gaussian scenarios, no single method provided the least biased and most precise estimates for both limits of a reference interval across all sample sizes, although the non-parametric approach performed the best for most scenarios. The hierarchy of the performances of the three methods was only impacted by sample size and skewness. Differences between reference interval estimates established by the three methods were inflated by variability. Whenever possible, laboratories should attempt to transform data to a Gaussian distribution and use the parametric approach to obtain the most optimal reference intervals. When this is not possible, laboratories should consider sample size and skewness as factors in their choice of reference interval estimation method. The consequences of false positives or false negatives may also serve as factors in this decision. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Thurison, Tine; Christensen, Ib J; Lund, Ida K; Nielsen, Hans J; Høyer-Hansen, Gunilla
2015-01-15
High levels of circulating forms of the urokinase-type plasminogen activator receptor (uPAR) are significantly associated to poor prognosis in cancer patients. Our aim was to determine biological variations and reference intervals of the uPAR forms in blood, and in addition, to test the clinical relevance of using these as cut-points in colorectal cancer (CRC) prognosis. uPAR forms were measured in citrated and EDTA plasma samples using time-resolved fluorescence immunoassays. Diurnal, intra- and inter-individual variations were assessed in plasma samples from cohorts of healthy individuals. Reference intervals were determined in plasma from healthy individuals randomly selected from a Danish multi-center cross-sectional study. A cohort of CRC patients was selected from the same cross-sectional study. The reference intervals showed a slight increase with age and women had ~20% higher levels. The intra- and inter-individual variations were ~10% and ~20-30%, respectively and the measured levels of the uPAR forms were within the determined 95% reference intervals. No diurnal variation was found. Applying the normal upper limit of the reference intervals as cut-point for dichotomizing CRC patients revealed significantly decreased overall survival of patients with levels above this cut-point of any uPAR form. The reference intervals for the different uPAR forms are valid and the upper normal limits are clinically relevant cut-points for CRC prognosis. Copyright © 2014 Elsevier B.V. All rights reserved.
Specific Immunoglobulin (Ig) G Reference Intervals for Common Food, Insect, and Mold Allergens.
Martins, Thomas B; Bandhauer, Michael E; Wilcock, Diane M; Hill, Harry R; Slev, Patricia R
2016-12-01
The clinical utility of serum IgG measurement in the diagnosis of allergy and food-induced hypersensitivity has been largely discredited. Recent studies, however, have shown that specific IgG can inhibit IgE mediated allergies, and may play a role in allergen specific desensitization. Accurate reference intervals for IgG specific allergens have not been widely established and are needed for better interpretation of serum antibody concentrations. In this study we established 64 IgG reference intervals for 48 common food allergens, 5 venoms, and 11 molds. Specific IgG concentrations were determined employing an automated fluorescent enzyme immunoassay on serum samples from 130 normal adults (65 males and 65 females), age range 18-69 y, mean 37.3 y. The lower reference interval limit for all allergens tested (n=64) was <2 mcg/mL. The median upper reference interval value for all 64 allergens was 12.9 mcg/mL, with Tuna (f40) having the lowest upper interval limit at 3.8 mcg/mL, and the mold Setomelanomma rostrate (m8) demonstrating the highest upper interval limit at 131 mcg/L. The considerable variation observed among the upper reference interval limits emphasizes the need for the establishment of allergen specific ranges for IgG. These newly established ranges should be a useful aid for clinicians in the interpretation of laboratory serum IgG results. © 2016 by the Association of Clinical Scientists, Inc.
Analytical Chemistry: A Literary Approach.
ERIC Educational Resources Information Center
Lucy, Charles A.
2000-01-01
Provides an anthology of references to descriptions of analytical chemistry techniques from history, popular fiction, and film which can be used to capture student interest and frame discussions of chemical techniques. (WRM)
Black-and-white photographic chemistry: A reference
NASA Technical Reports Server (NTRS)
Walker, E. D. (Compiler)
1986-01-01
This work is intended as a reference of black-and-white photographic chemistry. Included is a basic history of the photographic processes and a complete description of all chemicals used, formulas for the development and fixation process, and associated formulas such as cleaners, hardeners, and toners. The work contains a complete glossary of photographic terms, a trouble-shooting section listing causes and effects regarding photographic film and papers, and various conversion charts.
Coordinates and intervals in graph-based reference genomes.
Rand, Knut D; Grytten, Ivar; Nederbragt, Alexander J; Storvik, Geir O; Glad, Ingrid K; Sandve, Geir K
2017-05-18
It has been proposed that future reference genomes should be graph structures in order to better represent the sequence diversity present in a species. However, there is currently no standard method to represent genomic intervals, such as the positions of genes or transcription factor binding sites, on graph-based reference genomes. We formalize offset-based coordinate systems on graph-based reference genomes and introduce methods for representing intervals on these reference structures. We show the advantage of our methods by representing genes on a graph-based representation of the newest assembly of the human genome (GRCh38) and its alternative loci for regions that are highly variable. More complex reference genomes, containing alternative loci, require methods to represent genomic data on these structures. Our proposed notation for genomic intervals makes it possible to fully utilize the alternative loci of the GRCh38 assembly and potential future graph-based reference genomes. We have made a Python package for representing such intervals on offset-based coordinate systems, available at https://github.com/uio-cels/offsetbasedgraph . An interactive web-tool using this Python package to visualize genes on a graph created from GRCh38 is available at https://github.com/uio-cels/genomicgraphcoords .
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-03-26
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.
Guo, Wei; Song, Binbin; Shen, Junfei; Wu, Jiong; Zhang, Chunyan; Wang, Beili; Pan, Baishen
2015-08-25
To establish an indirect reference interval based on the test results of alanine aminotransferase stored in a laboratory information system. All alanine aminotransferase results were included for outpatients and physical examinations that were stored in the laboratory information system of Zhongshan Hospital during 2014. The original data were transformed using a Box-Cox transformation to obtain an approximate normal distribution. Outliers were identified and omitted using the Chauvenet and Tukey methods. The indirect reference intervals were obtained by simultaneously applying nonparametric and Hoffmann methods. The reference change value was selected to determine the statistical significance of the observed differences between the calculated and published reference intervals. The indirect reference intervals for alanine aminotransferase of all groups were 12 to 41 U/L (male, outpatient), 12 to 48 U/L (male, physical examination), 9 to 32 U/L (female, outpatient), and 8 to 35 U/L (female, physical examination), respectively. The absolute differences when compared with the direct results were all smaller than the reference change value of alanine aminotransferase. The Box-Cox transformation combined with the Hoffmann and Tukey methods is a simple and reliable technique that should be promoted and used by clinical laboratories.
Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea
2016-01-01
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients’ care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine. PMID:27019800
ERIC Educational Resources Information Center
Sumarni, Woro; Sudarmin; Supartono, Wiyanto
2016-01-01
The purpose of this research is to design assessment instrument to evaluate science generic skill (SGS) achievement and chemistry literacy in ethnoscience-integrated chemistry learning. The steps of tool designing refers to Plomp models including 1) Investigation Phase (Prelimenary Investigation); 2) Designing Phase (Design); 3)…
Predicting fire frequency with chemistry and climate
Richard P. Guyette; Michael C. Stambaugh; Daniel C. Dey; Rose-Marie Muzika
2012-01-01
A predictive equation for estimating fire frequency was developed from theories and data in physical chemistry, ecosystem ecology, and climatology. We refer to this equation as the Physical Chemistry Fire Frequency Model (PC2FM). The equation was calibrated and validated with North American fire data (170 sites) prior to widespread industrial influences (before ...
Guide for Teaching Chemistry-Physics Combined 1-2, 3-4 (PSSC - CHEMS).
ERIC Educational Resources Information Center
Millstone, H. George
This guide is written for a combined physics-chemistry course taught over a two-year period. The subject matter contains the major ideas in Chemical Education Materials Study (CHEMS) Chemistry and Physical Science Study Committee (PSSC) Physics. The guide includes discussion of text references, laboratory experiments, films, testing and evaluation…
ERIC Educational Resources Information Center
Liu, Yu; Taber, Keith S.
2016-01-01
Symbolic expressions are essential resources for producing knowledge, yet they are a source of learning difficulties in chemistry education. This study aims to employ social semiotics to analyse the symbolic representation of chemistry from two complementary perspectives, referred to here as contextual (i.e., historical) and functional. First, the…
Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping
2016-10-01
Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Electrocardiogram reference intervals for clinically normal wild-born chimpanzees (Pan troglodytes).
Atencia, Rebeca; Revuelta, Luis; Somauroo, John D; Shave, Robert E
2015-08-01
To generate reference intervals for ECG variables in clinically normal chimpanzees (Pan troglodytes). 100 clinically normal (51 young [< 10 years old] and 49 adult [≥ 10 years old]) wild-born chimpanzees. Electrocardiograms collected between 2009 and 2013 at the Tchimpounga Chimpanzee Rehabilitation Centre were assessed to determine heart rate, PR interval, QRS duration, QT interval, QRS axis, P axis, and T axis. Electrocardiographic characteristics for left ventricular hypertrophy (LVH) and morphology of the ST segment, T wave, and QRS complex were identified. Reference intervals for young and old animals were calculated as mean ± 1.96•SD for normally distributed data and as 5th to 95th percentiles for data not normally distributed. Differences between age groups were assessed by use of unpaired Student t tests. RESULTS Reference intervals were generated for young and adult wild-born chimpanzees. Most animals had sinus rhythm with small or normal P wave morphology; 24 of 51 (47%) young chimpanzees and 30 of 49 (61%) adult chimpanzees had evidence of LVH as determined on the basis of criteria for humans. Cardiac disease has been implicated as the major cause of death in captive chimpanzees. Species-specific ECG reference intervals for chimpanzees may aid in the diagnosis and treatment of animals with, or at risk of developing, heart disease. Chimpanzees with ECG characteristics outside of these intervals should be considered for follow-up assessment and regular cardiac monitoring.
Nonparametric spirometry reference values for Hispanic Americans.
Glenn, Nancy L; Brown, Vanessa M
2011-02-01
Recent literature sites ethnic origin as a major factor in developing pulmonary function reference values. Extensive studies established reference values for European and African Americans, but not for Hispanic Americans. The Third National Health and Nutrition Examination Survey defines Hispanic as individuals of Spanish speaking cultures. While no group was excluded from the target population, sample size requirements only allowed inclusion of individuals who identified themselves as Mexican Americans. This research constructs nonparametric reference value confidence intervals for Hispanic American pulmonary function. The method is applicable to all ethnicities. We use empirical likelihood confidence intervals to establish normal ranges for reference values. Its major advantage: it is model free, but shares asymptotic properties of model based methods. Statistical comparisons indicate that empirical likelihood interval lengths are comparable to normal theory intervals. Power and efficiency studies agree with previously published theoretical results.
ERIC Educational Resources Information Center
Niaz, Mansoor
2009-01-01
The objective of this study is to facilitate progressive transitions in chemistry teachers understanding of nature of science in the context of historical controversies. Selected controversies referred to episodes that form part of the chemistry curriculum both at secondary and university freshman level. The study is based on 17 in-service…
PASCAL Data Base File Description and Indexing Rules in Chemistry, Biology and Medicine.
ERIC Educational Resources Information Center
Gaillardin, R.; And Others
This report on the multidisciplinary PASCAL database describes the files and the indexing rules for chemistry, biology, and medicine. PASCAL deals with all aspects of chemistry within two subfiles whose combined yearly growth is about 100,000 references. The Biopascal file, organized in the two subfiles of Plant Science and Biology and Medicine,…
The Khat and Meow Meow Tale: Teaching the Relevance of Chemistry through Novel Recreational Drugs
ERIC Educational Resources Information Center
Fergus, Suzanne; Kellett, Kathryn; Gerhard, Ute
2015-01-01
Using current research and real-life scenarios to motivate students to understand chemistry principles is a key strategy in learning and teaching. An illustration of psychoactive drugs referred to as "legal highs" used in the U.K. and Europe is presented to highlight key chemistry principles and relate the importance of chemistry…
2014-01-01
Background Establishment of haematological and biochemical reference intervals is important to assess health of animals on individual and population level. Reference intervals for 13 haematological and 34 biochemical variables were established based on 88 apparently healthy free-ranging brown bears (39 males and 49 females) in Sweden. The animals were chemically immobilised by darting from a helicopter with a combination of medetomidine, tiletamine and zolazepam in April and May 2006–2012 in the county of Dalarna, Sweden. Venous blood samples were collected during anaesthesia for radio collaring and marking for ecological studies. For each of the variables, the reference interval was described based on the 95% confidence interval, and differences due to host characteristics sex and age were included if detected. To our knowledge, this is the first report of reference intervals for free-ranging brown bears in Sweden. Results The following variables were not affected by host characteristics: red blood cell, white blood cell, monocyte and platelet count, alanine transaminase, amylase, bilirubin, free fatty acids, glucose, calcium, chloride, potassium, and cortisol. Age differences were seen for the majority of the haematological variables, whereas sex influenced only mean corpuscular haemoglobin concentration, aspartate aminotransferase, lipase, lactate dehydrogenase, β-globulin, bile acids, triglycerides and sodium. Conclusions The biochemical and haematological reference intervals provided and the differences due to host factors age and gender can be useful for evaluation of health status in free-ranging European brown bears. PMID:25139149
Deaf Students, Teachers, and Interpreters in the Chemistry Lab.
ERIC Educational Resources Information Center
Seal, Brenda C.; Wynne, Dorothy; MacDonald, Gina
2002-01-01
Describes a summer research program at James Madison University targeting deaf and hard-of-hearing students and teachers participating in and collaborating on chemistry research with hearing students and teachers. (Contains 18 references.) (YDS)
Kutluturk, Faruk; Yildirim, Beytullah; Ozturk, Banu; Ozyurt, Huseyin; Bekar, Ulku; Sahin, Semsettin; Akturk, Yeliz; Akbas, Ali; Cetin, Ilhan; Etikan, Ilker
2014-01-01
The aim of the present study was to investigate the reference intervals for thyroid stimulating hormone (TSH) in healthy individuals with normal levels of serum free thyroxine (fT4) and without sonographic pathologies, and determine the effects of age, gender, and residence on the TSH reference intervals. This research was a population-based study conducted in 70 regions. The random sampling method was used to select the 1095 subjects of the study among inhabitants aged 18 and above. Patients who had a previous history of thyroid disease and had been taking medication were excluded from the study as this may have affected their fT4 or TSH levels. In addition, subjects who had serum fT4 without a reference range and abnormal ultrasonography findings were also excluded. A total of 408 subjects were used for establishing the reference intervals for TSH. The data for TSH in the study group were not normally distributed according to the Kolmogorov-Smirnov index. The geometric mean was 1.62 mIU/L, the median was 1.40 mIU/L, and the 95% reference intervals were 0.38-4.22 mIU/L. The median TSH level was higher in females compared to males (p < 0.05). In the female subjects 2.5th percentile of TSH was lower and 97.5th percentile was higher than those of males. The reference intervals of TSH were of lower values in subjects over 50 years old (p < 0.001). Studies suggest that determination of the TSH reference intervals may differ due to environmental influences or due to age, gender, and race. It is suggested that the lower limit of normal TSH for the adult Turkish population would be 0.38 mIU/L and the upper limit similar to the traditional value of 4.2 mIU/L. If each clinician uses their population-specific reference interval for TSH, thyroid function abnormalities can be accurately estimated.
Acid precipitation; an annotated bibliography
Wiltshire, Denise A.; Evans, Margaret L.
1984-01-01
This collection of 1660 bibliographies references on the causes and environmental effects of acidic atmospheric deposition was compiled from computerized literature searches of earth-science and chemistry data bases. Categories of information are (1) atmospheric chemistry (gases and aerosols), (2) precipitation chemistry, (3) transport and deposition (wet and dry), (4) aquatic environments (biological and hydrological), (5) terrestrial environments, (6) effects on materials and structures, (7) air and precipitation monitoring and data collection, and (8) modeling studies. References date from the late 1800 's through December 1981. The bibliography includes short summaries of most documents. Omitted are unpublished manuscripts, publications in press, master 's theses and doctoral dissertations, newspaper articles, and book reviews. Coauthors and subject indexes are included. (USGS)
Effect of wood ash application on soil solution chemistry of tropical acid soils: incubation study.
Nkana, J C Voundi; Demeyer, A; Verloo, M G
2002-12-01
The objective of this study was to determine the effect of wood ash application on soil solution composition of three tropical acid soils. Calcium carbonate was used as a reference amendment. Amended soils and control were incubated for 60 days. To assess soluble nutrients, saturation extracts were analysed at 15 days intervals. Wood ash application affects the soil solution chemistry in two ways, as a liming agent and as a supplier of nutrients. As a liming agent, wood ash application induced increases in soil solution pH, Ca, Mg, inorganic C, SO4 and DOC. As a supplier of elements, the increase in the soil solution pH was partly due to ligand exchange between wood ash SO4 and OH- ions. Large increases in concentrations of inorganic C, SO4, Ca and Mg with wood ash relative to lime and especially increases in K reflected the supply of these elements by wood ash. Wood ash application could represent increased availability of nutrients for the plant. However, large concentrations of basic cations, SO4 and NO3 obtained with higher application rates could be a concern because of potential solute transport to surface waters and groundwater. Wood ash must be applied at reasonable rates to avoid any risk for the environment.
Estimation of reference intervals from small samples: an example using canine plasma creatinine.
Geffré, A; Braun, J P; Trumel, C; Concordet, D
2009-12-01
According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.
Coley-Grant, Deon; Herbert, Mike; Cornes, Michael P; Barlow, Ian M; Ford, Clare; Gama, Rousseau
2016-01-01
We studied the impact on reference intervals, classification of patients with hypoalbuminaemia and albumin infusion prescriptions on changing from a bromocresol green (BCG) to a bromocresol purple (BCP) serum albumin assay. Passing-Bablok regression analysis and Bland-Altman plot were used to compare Abbott BCP and Roche BCG methods. Linear regression analysis was used to compare in-house and an external laboratory Abbott BCP serum albumin results. Reference intervals for Abbott BCP serum albumin were derived in two different laboratories using pathology data from adult patients in primary care. Prescriptions for 20% albumin infusions were compared one year before and one year after changing the albumin method. Abbott BCP assay had a negative bias of approximately 6 g/L compared with Roche BCG method.There was good agreement (y = 1.04 x - 1.03; R(2 )= 0.9933) between in-house and external laboratory Abbott BCP results. Reference intervals for the serum albumin Abbott BCP assay were 31-45 g/L, different to those recommended by Pathology Harmony and the manufacturers (35-50 g/L). Following the change in method there was a large increase in the number of patients classified as hypoalbuminaemic using Pathology Harmony references intervals (32%) but not when retrospectively compared to locally derived reference intervals (16%) compared with the previous year (12%). The method change was associated with a 44.6% increase in albumin prescriptions. This equated to an annual increase in expenditure of £35,234. We suggest that serum albumin reference intervals be method specific to prevent misclassification of albumin status in patients. Change in albumin methodology may have significant impact on hospital resources. © The Author(s) 2015.
Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M
2013-01-01
Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Blood samples were collected in the supine position from 1226 subjects, aged 5-84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results.
Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M
2016-01-01
Background Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Methods Blood samples were collected in the supine position from 1226 subjects, aged 5–84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Results Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. Conclusions These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results. PMID:23065528
What Chemistry To Teach Engineers?
ERIC Educational Resources Information Center
Hawkes, Stephen J.
2000-01-01
Examines possible general chemistry topics that would be most relevant and practical for engineering majors. Consults the Accreditation Board for Engineering and Technology (ABET), engineering textbooks, texts from other required subjects, and practicing engineers for recommendations. (Contains 24 references.) (WRM)
Fancher, J P; Aitkenhead-Peterson, J A; Farris, T; Mix, K; Schwab, A P; Wescott, D J; Hamilton, M D
2017-10-01
Soil samples from the Forensic Anthropology Research Facility (FARF) at Texas State University, San Marcos, TX, were analyzed for multiple soil characteristics from cadaver decomposition islands to a depth of 5centimeters (cm) from 63 human decomposition sites, as well as depths up to 15cm in a subset of 11 of the cadaver decomposition islands plus control soils. Postmortem interval (PMI) of the cadaver decomposition islands ranged from 6 to 1752 days. Some soil chemistry, including nitrate-N (NO 3 -N), ammonium-N (NH 4 -N), and dissolved inorganic carbon (DIC), peaked at early PMI values and their concentrations at 0-5cm returned to near control values over time likely due to translocation down the soil profile. Other soil chemistry, including dissolved organic carbon (DOC), dissolved organic nitrogen (DON), orthophosphate-P (PO 4 -P), sodium (Na + ), and potassium (K + ), remained higher than the control soil up to a PMI of 1752days postmortem. The body mass index (BMI) of the cadaver appeared to have some effect on the cadaver decomposition island chemistry. To estimate PMI using soil chemistry, backward, stepwise multiple regression analysis was used with PMI as the dependent variable and soil chemistry, body mass index (BMI) and physical soil characteristics such as saturated hydraulic conductivity as independent variables. Measures of soil parameters derived from predator and microbial mediated decomposition of human remains shows promise in estimating PMI to within 365days for a period up to nearly five years. This persistent change in soil chemistry extends the ability to estimate PMI beyond the traditionally utilized methods of entomology and taphonomy in support of medical-legal investigations, humanitarian recovery efforts, and criminal and civil cases. Copyright © 2017 Elsevier B.V. All rights reserved.
Karsten, Schober; Stephanie, Savino; Vedat, Yildiz
2017-11-10
The objective of the study was to evaluate the effects of body weight (BW), breed, and sex on two-dimensional (2D) echocardiographic measures, reference ranges, and prediction intervals using allometrically-scaled data of left atrial (LA) and left ventricular (LV) size and LV wall thickness in healthy cats. Study type was retrospective, observational, and clinical cohort. 150 healthy cats were enrolled and 2D echocardiograms analyzed. LA diameter, LV wall thickness, and LV dimension were quantified using three different imaging views. The effect of BW, breed, sex, age, and interaction (BW*sex) on echocardiographic variables was assessed using univariate and multivariate regression and linear mixed model analysis. Standard (using raw data) and allometrically scaled (Y=a × M b ) reference intervals and prediction intervals were determined. BW had a significant (P<0.05) independent effect on 2D variables whereas breed, sex, and age did not. There were clinically relevant differences between reference intervals using mean ± 2SD of raw data and mean and 95% prediction interval of allometrically-scaled variables, most prominent in larger (>6 kg) and smaller (<3 kg) cats. A clinically relevant difference between thickness of the interventricular septum (IVS) and dimension of the LV posterior wall (LVPW) was identified. In conclusion, allometric scaling and BW-based 95% prediction intervals should be preferred over conventional 2D echocardiographic reference intervals in cats, in particular in small and large cats. These results are particularly relevant to screening examinations for feline hypertrophic cardiomyopathy.
Assessing the performance of handheld glucose testing for critical care.
Kost, Gerald J; Tran, Nam K; Louie, Richard F; Gentile, Nicole L; Abad, Victor J
2008-12-01
We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStriptrade mark, NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for > or =75 mg/dL, 100% were within tolerance. Paired differences (handheld minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r2 = 0.995. LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.
BIBLIOGRAPHIC GUIDE FOR ADVANCED PLACEMENT, CHEMISTRY.
ERIC Educational Resources Information Center
WILLIAMS, HARRY; KING, CLYDE
REFERENCES AND AUDIOVISUAL MATERIALS ARE LISTED IN THIS GUIDE FOR SECONDARY SCHOOL ADVANCED PLACEMENT CHEMISTRY TEACHERS AND LIBRARIANS. BOOKS, PERIODICALS, WALL CHARTS, FILMS, AND FILMSTRIPS ARE INCLUDED. CITATIONS ARE COMPLETE AND INCLUDE INFORMATION PERTINENT TO THE ACQUISITION OF THE MATERIALS. (AG)
Markers of Renal Function and Injury
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ragan, Harvey A.; Weller, Richard E.
1999-04-15
Designed to aid the laboratory animal veterinarian, researcher, or toxicologist in the proper evaluation of organ function, this updated and revised edition provides the only comprehensive reference of the clinical chemistry of laboratory animals. With contributions from recognized experts in the field, new chapters are included that focus on the pig and the ferret, while many chapters have been rewritten. Expanded coverage was given to urine chemistry, hormones, including melatonin, and the control mechanisms of analytes. Reference values are given in both conventional and S.I. units.
Calder, W John; Horn, Kevin J; St Clair, Samuel B
2011-06-01
Disturbance patterns strongly influence plant community structure. What remains less clear, particularly at a mechanistic level, is how changes in disturbance cycles alter successional outcomes in plant communities. There is evidence that fire suppression is resulting in longer fire return intervals in subalpine forests and that these lengthened intervals increase competitive interactions between aspen and conifer species. We conducted a field and greenhouse study to compare photosynthesis, growth and defense responses of quaking aspen and subalpine fir regeneration under light reductions and shifts in soil chemistry that occur as conifers increase in dominance. The studies demonstrated that aspen regeneration was substantially more sensitive to light and soil resource limitations than that of subalpine fir. For aspen, light reductions and/or shifts in soil chemistry limited height growth, biomass gain, photosynthesis and the production of defense compounds (phenolic glycosides and condensed tannins). Biomass gain and phenolic glycoside concentrations were co-limited by light reduction and changes in soil chemistry. In contrast, subalpine fir seedlings tended to be more tolerant of low light conditions and showed no sensitivity to changes in soil chemistry. Unlike aspen, subalpine fir increased its root to shoot ratio on conifer soils, which may partially explain its maintenance of growth and defense. The results suggest that increasing dominance of conifers in subalpine forests alters light conditions and soil chemistry in a way that places greater physiological and growth constraints on aspen than subalpine fir, with a likely outcome being more successful recruitment of conifers and losses in aspen cover.
Quality assurance for health and environmental chemistry: 1990
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautier, M.A.; Gladney, E.S.; Koski, N.L.
1991-10-01
This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group (HSE-9) at the Los Alamos National Laboratory. The philosophy, methodology, computing resources, and laboratory information management system used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1990.
Resampling methods in Microsoft Excel® for estimating reference intervals
Theodorsson, Elvar
2015-01-01
Computer- intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular. Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples. PMID:26527366
Resampling methods in Microsoft Excel® for estimating reference intervals.
Theodorsson, Elvar
2015-01-01
Computer-intensive resampling/bootstrap methods are feasible when calculating reference intervals from non-Gaussian or small reference samples. Microsoft Excel® in version 2010 or later includes natural functions, which lend themselves well to this purpose including recommended interpolation procedures for estimating 2.5 and 97.5 percentiles. The purpose of this paper is to introduce the reader to resampling estimation techniques in general and in using Microsoft Excel® 2010 for the purpose of estimating reference intervals in particular. Parametric methods are preferable to resampling methods when the distributions of observations in the reference samples is Gaussian or can transformed to that distribution even when the number of reference samples is less than 120. Resampling methods are appropriate when the distribution of data from the reference samples is non-Gaussian and in case the number of reference individuals and corresponding samples are in the order of 40. At least 500-1000 random samples with replacement should be taken from the results of measurement of the reference samples.
Predictive value and efficiency of laboratory testing.
Galen, R S
1980-11-01
Literature on determining reference values and reference intervals on "normal" or "healthy" individuals is abundant. It is impossible, however, to evaluate a data set of reference values and select a suitable reference interval that will be meaningful for the practice of medicine. The reference interval, no matter how derived statistically, tells us nothing about disease. This is the main reason the concepts of "normal values" have failed us and why "reference values" will prove similarly disappointing. By studying these same constituents in a variety of disease states as well, it will be possible to select "referent values" that will make the test procedure meaningful for diagnostic purposes. In order to obtain meaningful referent values for predicting disease, it is necessary to study not only the "healthy" reference population, but patients with the disease in question, and patients who are free of the disease in question but who have other diseases. Studies of this type are not frequently found for laboratory tests that are in common use today.
He, Qili; Su, Guoming; Liu, Keliang; Zhang, Fangcheng; Jiang, Yong; Gao, Jun; Liu, Lida; Jiang, Zhongren; Jin, Minwu; Xie, Huiping
2017-01-01
Hematologic and biochemical analytes of Sprague-Dawley rats are commonly used to determine effects that were induced by treatment and to evaluate organ dysfunction in toxicological safety assessments, but reference intervals have not been well established for these analytes. Reference intervals as presently defined for these analytes in Sprague-Dawley rats have not used internationally recommended statistical method nor stratified by sex. Thus, we aimed to establish sex-specific reference intervals for hematologic and biochemical parameters in Sprague-Dawley rats according to Clinical and Laboratory Standards Institute C28-A3 and American Society for Veterinary Clinical Pathology guideline. Hematology and biochemistry blood samples were collected from 500 healthy Sprague-Dawley rats (250 males and 250 females) in the control groups. We measured 24 hematologic analytes with the Sysmex XT-2100i analyzer, 9 biochemical analytes with the Olympus AU400 analyzer. We then determined statistically relevant sex partitions and calculated reference intervals, including corresponding 90% confidence intervals, using nonparametric rank percentile method. We observed that most hematologic and biochemical analytes of Sprague-Dawley rats were significantly influenced by sex. Males had higher hemoglobin, hematocrit, red blood cell count, red cell distribution width, mean corpuscular volume, mean corpuscular hemoglobin, white blood cell count, neutrophils, lymphocytes, monocytes, percentage of neutrophils, percentage of monocytes, alanine aminotransferase, aspartate aminotransferase, and triglycerides compared to females. Females had higher mean corpuscular hemoglobin concentration, plateletcrit, platelet count, eosinophils, percentage of lymphocytes, percentage of eosinophils, creatinine, glucose, total cholesterol and urea compared to males. Sex partition was required for most hematologic and biochemical analytes in Sprague-Dawley rats. We established sex-specific reference intervals, including corresponding 90% confidence intervals, for Sprague-Dawley rats. Understanding the significant discrepancies in hematologic and biochemical analytes between male and female Sprague-Dawley rats provides important insight into physiological effects in test rats. Establishment of locally sex-specific reference intervals allows a more precise evaluation of animal quality and experimental results of Sprague-Dawley rats in our toxicology safety assessment.
Van Hemert, Caroline R.; Handel, Colleen M.
2016-01-01
We measured serum chemistries in wild Black-capped Chickadees (Poecile atricapillus) from Alaska to test for potential differences associated with beak deformities characteristic of avian keratin disorder. Lower uric acid in affected birds was the only difference detected between groups, although sample sizes were small. This difference could be associated with fasting or malnutrition in birds with beak deformities, but it is challenging to interpret its biologic significance without reference values. Black-capped Chickadees had high levels of aspartate aminotransferase, lactate dehydrogenase, and creatine kinase relative to reference values for companion birds. However, all serum chemistry parameters from our study were within the range of values reported from other apparently healthy wild-caught birds.
Synthesis of Aspirin: A General Chemistry Experiment.
ERIC Educational Resources Information Center
Olmsted, John III
1998-01-01
Describes the redesign of the first semester general chemistry laboratory at the college level. An organic component is included in the redesign and it provides students with explicit examples of several types of operations in which chemists engage. Contains 16 references. (DDR)
Defining life: connecting robotics and chemistry.
Brack, André; Troublé, Michel
2010-04-01
Life is commonly referred as open systems driven by organic chemistry capable to self reproduce and to evolve. The notion of life has also been extended to non chemical systems such as robots. The key characteristics of living systems, i.e. autonomy, self-replication, self-reproduction, self-organization, self-aggregation, autocatalysis, as defined in chemistry and in robotics, are compared in a dialogue between a chemist and a robotitian.
Clinical biochemistry of pregnant and nursing mares.
Harvey, John W; Pate, Melanie G; Kivipelto, Jan; Asquith, Richard L
2005-09-01
Pregnancy and lactation result in increased metabolic demands. Although homeostatic mechanisms function to keep substances in blood at relatively constant levels, some changes in the concentrations of routine clinical chemistry analytes are likely to occur. The purpose of this study was to determine what physiological changes occur in serum clinical biochemistry analytes in pregnant and nursing mares, and to determine whether the changes were substantial enough to warrant separate reference intervals for pregnant or lactating horses. Forty-two Quarter Horse, Thoroughbred, Saddlebred, Standardbred and Morgan mares were entered into the study while pregnant. They were bled once each month through birth. Studies were continued on 20 mares until their foals were weaned. Test results were tabulated by time before or after birth. Serum biochemistry values were determined by standard methods using automated analyzers. Test results were analyzed using the Kruskal-Wallis 1-way ANOVA on ranks. If a significant difference was found (P<.05), Dunn's multiple comparison procedure was performed on all pairs. Results from pregnant and nursing mares also were compared with a reference group of 19 open, nonlactating mares. Serum triglyceride, potassium, creatinine, and total bilirubin concentrations were lower during lactation than during pregnancy. Serum calcium concentration also was slightly decreased at 2 time points during lactation. Triglyceride concentration was highest during midgestation, while bilirubin and creatinine values increased, and potassium and calcium remained constant during pregnancy. Serum urea concentration also remained constant during pregnancy but increased during lactation. Serum phosphate concentration was lowest during midgestation and highest during lactation. Total CO2 values were highest, and anion gaps were lowest, during midgestation. No significant differences were found in serum albumin, globulin, albumin:globulin ratio, total protein, or glucose values. When compared with the reference group of open mares, serum triglyceride, potassium, bilirubin, and total CO2 concentrations were lower, and anion gap was higher in horses that were nursing. Although most biochemical values remained relatively constant, significant differences were observed during pregnancy and lactation. Changes in the concentrations of triglycerides, potassium, bilirubin, total CO2, and anion gap during lactation were substantial enough to warrant separate reference intervals for lactating horses.
Strand, Martin Frank; Fredriksen, Per Morten; Hjelle, Ole Petter; Lindberg, Morten
2018-05-01
Elevated serum lipid concentrations in childhood are thought to be risk factors for the development of cardiovascular disease later in life. The present study aims to provide age- and gender-related reference intervals for total cholesterol (TC), high-density lipoprotein (HDL) cholesterol, and non-HDL cholesterol in healthy school children. We also investigated the prevalence of dyslipidaemia using the published criteria for these biomarkers. Venous blood and anthropometric data were collected from 1340 children in the HOPP study, aged between 6 and 12 years. Age- and gender-related reference intervals (2.5th and 97.5th percentiles) were established according to the IFCC recommendations, using the software RefVal 4.10. Gender differences were observed for total cholesterol and non-HDL cholesterol, but not for HDL cholesterol. Age differences were observed for total cholesterol. The reference intervals were in the range of 3.1-5.9 mmol/L for total cholesterol, 1.0-2.4 mmol/L for HDL cholesterol and 1.4-4.2 mmol/L for non-HDL cholesterol. Dyslipidaemia prevalence was as follows: increased TC 9.6%, decreased HDL 1.6%, and increased non-HDL 5.6%. Age- and gender-related reference intervals in a Norwegian population are similar to those reported in other countries. The prevalence of dyslipidaemia among Norwegian children is significant, emphasising the importance of appropriate reference intervals in clinical practice.
2013-01-01
Background Previous studies have reported the lower reference limit (LRL) of quantitative cord glucose-6-phosphate dehydrogenase (G6PD), but they have not used approved international statistical methodology. Using common standards is expecting to yield more true findings. Therefore, we aimed to estimate LRL of quantitative G6PD detection in healthy term neonates by using statistical analyses endorsed by the International Federation of Clinical Chemistry (IFCC) and the Clinical and Laboratory Standards Institute (CLSI) for reference interval estimation. Methods This cross sectional retrospective study was performed at King Abdulaziz Hospital, Saudi Arabia, between March 2010 and June 2012. The study monitored consecutive neonates born to mothers from one Arab Muslim tribe that was assumed to have a low prevalence of G6PD-deficiency. Neonates that satisfied the following criteria were included: full-term birth (37 weeks); no admission to the special care nursery; no phototherapy treatment; negative direct antiglobulin test; and fathers of female neonates were from the same mothers’ tribe. The G6PD activity (Units/gram Hemoglobin) was measured spectrophotometrically by an automated kit. This study used statistical analyses endorsed by IFCC and CLSI for reference interval estimation. The 2.5th percentiles and the corresponding 95% confidence intervals (CI) were estimated as LRLs, both in presence and absence of outliers. Results 207 males and 188 females term neonates who had cord blood quantitative G6PD testing met the inclusion criteria. Method of Horn detected 20 G6PD values as outliers (8 males and 12 females). Distributions of quantitative cord G6PD values exhibited a normal distribution in absence of the outliers only. The Harris-Boyd method and proportion criteria revealed that combined gender LRLs were reliable. The combined bootstrap LRL in presence of the outliers was 10.0 (95% CI: 7.5-10.7) and the combined parametric LRL in absence of the outliers was 11.0 (95% CI: 10.5-11.3). Conclusion These results contribute to the LRL of quantitative cord G6PD detection in full-term neonates. They are transferable to another laboratory when pre-analytical factors and testing methods are comparable and the IFCC-CLSI requirements of transference are satisfied. We are suggesting using estimated LRL in absence of the outliers as mislabeling G6PD-deficient neonates as normal is intolerable whereas mislabeling G6PD-normal neonates as deficient is tolerable. PMID:24016342
Liver function testing on the Abaxis Piccolo Xpress: Use in Ebola virus disease protocols.
Owen, William E; Caron, Justin E; Genzen, Jonathan R
2015-06-15
Laboratories that choose a point-of-care approach for liver function testing in patients undergoing evaluation for Ebola virus disease (EVD) have few options to choose from. The primary objective of this study was to conduct a performance characterization of a Clinical Laboratory Improvement Amendments (CLIA)-waived liver function panel on the Abaxis Piccolo® Xpress chemistry analyzer. The secondary objectives were to evaluate multiple specimen types, characterize whole blood specimen stability, and validate disposable exact transfer pipettes. Our final objective was to assess instrument airflow from a biosafety perspective. An instrument performance characterization, including precision, linearity, accuracy, reference interval verification, and specimen type evaluation was conducted using Liver Panel Plus reagent discs on the Piccolo® Xpress. All assays demonstrated acceptable linearity (slopes, 0.938-1.061; observed error, 0.8-6.3%). Assay precision was 0.0-3.6% (%CV; within-day studies) and 0.9-5.6% (between-day studies). Method comparison experiments (versus Roche cobas c502/c702 chemistry analyzers) showed excellent correlation for most assays, although a few notable differences were observed (Piccolo versus Roche): alkaline phosphatase, -18.6%; amylase, -29.0%; total bilirubin, +0.3mg/dl. Pre-programmed reference intervals were verified except for the alkaline phosphatase (male and female) and alanine aminotransferase (female), which had greater than 10% of results fall below the programmed ranges. Piccolo instrument results were largely consistent across specimen types tested (lithium-heparin whole blood, lithium-heparin plasma, and serum), although some statistical differences were observed for aspartate aminotransferase, gamma glutamyltransferase, and total protein. Whole blood time course studies demonstrated that some analytes (albumin, amylase, and total protein) showed remarkable stability, while others (such as aspartate aminotransferase) showed a slight trend toward decreased activity over time. Exact volume transfer pipettes provided an effective disposable option for disc loading. Finally, airflow studies suggested that, in the context of EVD protocols, instrument placement in a biosafety level (BSL) 2 cabinet or greater is justified. Given its analytical performance and ease of operation, the Piccolo Xpress was transferred to a BSL-2 cabinet in our BSL-3 suite for use in our hospital's diagnostic protocol for providing liver function testing in patients undergoing evaluation for EVD. Copyright © 2015 Elsevier B.V. All rights reserved.
Charles C. Rhoades; Deborah Entwistle; Dana Butler
2011-01-01
The 2002 Hayman Fire was the largest fire in recent Colorado history (558 km2). The extent of high severity combustion and possible effects on Denver's water supply focussed public attention on the effects of wildfire on water quality.Wemonitored stream chemistry, temperature and sediment before the fire and at monthly intervals for 5 years after the fire. The...
Overgaard, Martin; Pedersen, Susanne Møller
2017-10-26
Hyperprolactinemia diagnosis and treatment is often compromised by the presence of biologically inactive and clinically irrelevant higher-molecular-weight complexes of prolactin, macroprolactin. The objective of this study was to evaluate the performance of two macroprolactin screening regimes across commonly used automated immunoassay platforms. Parametric total and monomeric gender-specific reference intervals were determined for six immunoassay methods using female (n=96) and male sera (n=127) from healthy donors. The reference intervals were validated using 27 hyperprolactinemic and macroprolactinemic sera, whose presence of monomeric and macroforms of prolactin were determined using gel filtration chromatography (GFC). Normative data for six prolactin assays included the range of values (2.5th-97.5th percentiles). Validation sera (hyperprolactinemic and macroprolactinemic; n=27) showed higher discordant classification [mean=2.8; 95% confidence interval (CI) 1.2-4.4] for the monomer reference interval method compared to the post-polyethylene glycol (PEG) recovery cutoff method (mean=1.8; 95% CI 0.8-2.8). The two monomer/macroprolactin discrimination methods did not differ significantly (p=0.089). Among macroprolactinemic sera evaluated by both discrimination methods, the Cobas and Architect/Kryptor prolactin assays showed the lowest and the highest number of misclassifications, respectively. Current automated immunoassays for prolactin testing require macroprolactin screening methods based on PEG precipitation in order to discriminate truly from falsely elevated serum prolactin. While the recovery cutoff and monomeric reference interval macroprolactin screening methods demonstrate similar discriminative ability, the latter method also provides the clinician with an easy interpretable monomeric prolactin concentration along with a monomeric reference interval.
Pediatric reference intervals for random urine calcium, phosphorus and total protein.
Slev, Patricia R; Bunker, Ashley M; Owen, William E; Roberts, William L
2010-09-01
The aim of this study was to establish age appropriate reference intervals for calcium (Ca), phosphorus (P) and total protein (UTP) in random urine samples. All analytes were measured using the Roche MODULAR P analyzer and normalized to creatinine (Cr). Our study cohort consisted of 674 boys and 728 girls between 7 and 17 years old (y.o.), which allowed us to determine the central 95% reference intervals with 90% confidence intervals by non-parametric analysis partitioned by both gender and 2-year age intervals for each analyte [i.e. boys in age group 7-9 years (7-9 boys); girls in age group 7-9 years (7-9 girls), etc.]. Results for the upper limits of the central 95% reference interval were: for Ca/Cr, 0.27 (16,17 y.o.) to 0.46 mg/mg (7-9 y.o.) for the girls and 0.26 (16,17 y.o.) to 0.43 mg/mg (7-9 y.o.) for the boys; for P/Cr, 0.85 (16,17 y.o.) to 1.44 mg/mg (7-9 y.o.) for the girls and 0.87 (16,17 y.o.) to 1.68 mg/mg (7-9 y.o.) for the boys; for UTP/Cr, 0.30 (7-9 y.o.) to 0.34 mg/mg (10-12 y.o.) for the girls and 0.19 (16,17, y.o.) to 0.26 mg/mg (13-15 y.o.) for the boys. Upper reference limits decreased with increasing age, and age was a statistically significant variable for all analytes. Eight separate age- and gender-specific reference intervals are proposed per analyte.
What's Wrong with Cookbooks? A Reply to Ault
ERIC Educational Resources Information Center
Monteyne, Kereen; Cracolice, Mark S.
2004-01-01
The work done in a chemistry laboratory is compared to cooking, as both processes use books for reference. It is felt that cooking and chemistry are complex processes and are creative endeavors that require skills beyond those developed by merely following the directions.
Natural variability of pCO2 and pH in the Atlantic and Pacific coastal margins of the U.S
NASA Astrophysics Data System (ADS)
Sutton, A. J.; Sabine, C. L.; Feely, R. A.; Newton, J.; Salisbury, J.; Vandemark, D. C.; Musielewicz, S. B.; Maenner-Jones, S.; Bott, R.; Lawrence-Slavas, N.
2011-12-01
The discovery that seawater chemistry is changing as a result of carbon dioxide (CO2) emissions, referred to as "ocean acidification", has prompted a large effort to understand how this changing chemistry will impact marine life. Changes in carbon chemistry have been documented in the open ocean; however, in dynamic coastal systems where many marine species live, ocean acidification and the natural biogeochemical variability that organisms are currently exposed to are poorly quantified. In 2010 we began equipping coastal moorings currently measuring pCO2 with pH and other biogeochemical sensors to measure ocean acidification parameters at 3 hour intervals in the surface water. Here we present the magnitude and diurnal to seasonal variability of pCO2 and pH during the first year of observations at 2 sites in the Atlantic and Pacific coastal margins of the U.S.: the Gulf of Maine and outer coast of Washington state. Both the magnitude and range of pCO2 and pH values were much greater at the coastal moorings compared to the open ocean mooring at Ocean Station Papa in the North Pacific and also varied between the two coastal mooring sites. We observed maximum pCO2 values in coastal waters exceeding predicted values for the open ocean at 2x pre-industrial CO2 levels. The range of pCO2 and pH values during this time series was approximately 4 times the range observed at open ocean mooring Papa (2007-2011 time series). In many cases, large variance was observed at short time scales, with values fluctuating more than 200 μatm pCO2 and 0.2 pH between 3-hour cycles. These types of observations are critical for understanding how ocean acidification will manifest in naturally dynamic coastal systems and for informing the experimental design of species response studies that aim to mimic carbon chemistry experienced by coastal marine organisms.
NASA Astrophysics Data System (ADS)
Greaves, M.; Elderfield, H.; Hodell, D. A.; Skinner, L. C.; Sevilgen, D.; Grauel, A. L.; de la Fuente, M.; Misra, S.
2014-12-01
A significant body of work exists on the chemistry of pore waters from DSDP and ODP drilling cores (e.g. Gieskes 1975; Sayles 1981) showing large gradients in sea salt cations and anions interpreted in terms of diagenetic reactions such as the formation of Mg-rich clays and dolomite formation (Higgins and Schrag, 2010). Another class of diagenetic reactions involves the breakdown of organic matter and trace element behaviour (Froelich et al., 1979). The translation of chemical gradients into fluxes requires estimates of pore water chemistry across the sea water - sediment surface boundary. Additionally, the use of the chemistry of benthic foraminiferal calcite for seawater paleochemistry requires estimation of the chemistry of pore waters which may differ from that of bottom seawater because of diagenetic reactions. In this work we have collected multi core samples from 10 core sites on cruise RRS James Cook JC089 on the southwest Iberian continental margin. Pore waters were extracted from the core surface and at 1 cm depth intervals down core (typically to ~40 cm depth) using Rhizon samplers and analysed for Alkalinity, DIC, ∂13C and Na, K, Mg, Ca, Li, Mn, Fe, Ba, B, Sr by atomic emission spectrophotometry as well as O2 penetration and pH by microelectrodes. This has allowed us to inspect chemical behavior at the bottom water - sediment interface. Some examples of results are a large gradient in ∂13C of DIC, the similarity of zero O2 penetration followed by an increase in Mn concentration and then decrease to zero, the similarity of Li to Mn and, in contrast to much DSDP/ODP work, Ca2+ and Mg2+both decrease with depth in pore waters near the sediment surface. References: Gieskes J.M. Annu. Rev. Earth Planet. Sci. 3, 433 (1975). Sayles F. L. Geochim. Cosmochim. Acta45, 1061 (1981). Higgins J.A. and D.P. Schrag. Geochim. Cosmochim. Acta.74, 5039 (2010). Froelich, P.N., et al., Geochim. Cosmochim. Acta. 43, 1075 (1979).
Off-set stabilizer for comparator output
Lunsford, James S.
1991-01-01
A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.
ERIC Educational Resources Information Center
Henry, Renee Monica
2017-01-01
Reported here is a study of an interactive component to General Chemistry I and General Chemistry II where a new pedagogy for taking notes in class was developed. These notes, called key word created class notes, prompted students to locate information using the Internet guided by a key word. Reference Web sites were added to a next generation of…
Evaluation of an anal sac adenocarcinoma tumor in a Spitz dog.
Javanbakht, Javad; Tavassoli, Abbas; Sabbagh, Atefeh; Hassan, Mehdy Aghamohammmad; Samakkhah, Shohreh Alian; Shafiee, Radmehr; Lakzian, Ali; Ghalee, Vahideh Rahmani; Gharebagh, Sonia Shoja
2013-01-01
A 9-year-old emasculated male Spitz with tenesmus and constipation had a subcutaneous mass at the left ventral aspect of the anus with history of polyuria and polydipsia. A complete blood cell count, serum biochemistry panel, and urinalysis (cystocentesis sample) were evaluated. Abnormalities in the serum biochemistry panel included a mildly elevated serum cholesterol concentration (7.28 mmol/L; reference interval, 2.70-5.94 mmol/L), increased serum alkaline phosphatase activity (184 U/L; reference interval, 9-90 U/L), alanine transaminase (122 U/L; reference interval, 5-60 U/L) activity and aspartate aminotransferase (80 U/L; reference interval, 5-55 U/L) activity, severe increased total calcium concentration (16.3 mg/dL; reference interval, 8.2-12.4 mg/dL or 9.3-11.4 mg/dL), and decreased total calcium concentration (3.4 mg/dL, reference interval, 2.5-5.6mg/dL). Furthermore, testing revealed an increased intact parathyroid hormone concentration (38.6 pmol/L; reference interval, 3-17 pmol/L). On cytologic and histopathologic examinations, various types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Based on location and histologic features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs.
International year of Chemistry 2011. A guide to the history of clinical chemistry.
Kricka, Larry J; Savory, John
2011-08-01
This review was written as part of the celebration of the International Year of Chemistry 2011. In this review we provide a chronicle of the history of clinical chemistry, with a focus on North America. We outline major methodological advances and trace the development of professional societies and journals dedicated to clinical chemistry. This review also serves as a guide to reference materials for those interested in the history of clinical chemistry. The various resources available, in sound recordings, videos, moving images, image and document archives, museums, and websites dedicated to diagnostic company timelines, are surveyed. These resources provide a map of how the medical subspecialty of clinical chemistry arrived at its present state. This information will undoubtedly help visionaries to determine in which direction clinical chemistry will move in the future.
Reference intervals for plasma-free amino acid in a Japanese population.
Yamamoto, Hiroyuki; Kondo, Kazuhiro; Tanaka, Takayuki; Muramatsu, Takahiko; Yoshida, Hiroo; Imaizumi, Akira; Nagao, Kenji; Noguchi, Yasushi; Miyano, Hiroshi
2016-05-01
Plasma amino acid concentrations vary with various diseases. Although reference intervals are useful in daily clinical practice, no reference intervals have been reported for plasma amino acids in a large Japanese population. Reference individuals were selected from 7685 subjects examined with the Japanese Ningen Dock in 2008. A total of 1890 individuals were selected based on exclusion criteria, and the reference samples were selected after the outlier samples for each amino acid concentration were excluded. The lower limit of the reference intervals for the plasma amino acid concentrations was set at the 2.5th percentile and the upper limit at the 97.5th percentile. By use of the nested analysis of variance, we analysed a large dataset of plasma samples and the effects of background factors (sex, age and body mass index [BMI]) on the plasma amino acid concentrations. Most amino acid concentrations were related to sex, especially those of branched-chained amino acid. The citrulline, glutamine, ornithine and lysine concentrations were related to age. The glutamate concentration was related to body mass index. The concentrations of most amino acids are more strongly related to sex than to age or body mass index. Our results indicate that the reference intervals for plasma amino acid concentrations should be stratified by sex when the background factors of age and body mass index are considered. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Age and sex variation in serum albumin concentration: an observational study.
Weaving, Gary; Batstone, Gifford F; Jones, Richard G
2016-01-01
In the UK, a common reference interval for serum albumin is widely used irrespective of age or sex. Implicit in this is that laboratories produce analytically similar results. This paper challenges the validity of this approach. A three-week collection of results sent to all primary care centres in England has been analysed by age, sex and laboratory. In all, 1,079,193 serum albumin reports were included in this analysis. The mean population serum albumin concentration increases to peak at around age 20 years and then decreases with increasing age. Values in females decrease more rapidly but become close to male values at 60 years. The variation between laboratories was large and potentially clinically significant. Reference intervals for serum albumin should be stratified by age and sex. Until there is greater methodological standardization, laboratories should determine their own reference intervals and not accept a single consensus reference interval. © The Author(s) 2015.
Qin, X; Tang, G; Gao, R; Guo, Z; Liu, Z; Yu, S; Chen, M; Tao, Z; Li, S; Liu, M; Wang, L; Hou, L; Xia, L; Cheng, X; Han, J; Qiu, L
2017-08-01
The aim of this study was to investigate the reference interval of protein-induced vitamin K absence or antagonist-II (PIVKA-II) in China population and to evaluate its medical decision level for hepatocellular carcinoma (HCC) diagnosis. To determine the reference range for Chinese individuals, a total of 855 healthy subjects in five typical regions of China were enrolled in this study to obtain a 95% reference interval. In a case-control study which recruited the subjects diagnosed with HCC, metastatic liver cancer, bile duct cancer, hepatitis, cirrhosis, other benign liver diseases and the subjects administrated anticoagulant, receiver operating characteristic analysis was used to determine PIVKA-II cutoff value for a medical decision. The concentration of PIVKA-II had no relationship with age or gender and that region was a significant factor associated with the level of PIVKA-II. The 95% reference interval determined in this study for PIVKA-II in Chinese healthy individuals was 28 mAU/mL, and the cutoff value which to distinguish patients with HCC from disease control groups is 36.5 mAU/mL. In clinical applications, it is recommended that each laboratory chooses their own reference interval based on the regional population study or cutoff value for disease diagnosis. © 2017 John Wiley & Sons Ltd.
An investigation of the solar zenith angle variation of D-region ionization
NASA Technical Reports Server (NTRS)
Ratnasiri, P. A. J.; Sechrist, C. F., Jr.
1975-01-01
Model calculations are carried out with a view to interpreting the solar zenith angle variation of D-region ionization. A model is developed for the neutral chemistry including the transport terms relating to molecular and eddy diffusion. The diurnal behavior is described of the minor neutral constituents formed in an oxygen-hydrogen-nitrogen atmosphere, in the height interval between 30 and 120 km. Computations carried out for two cases of the eddy diffusion coefficients models indicate that the constituents which are important for the D-region positive-ion chemistry do not show a significant variation with zenith angle for values up to 75 deg over the D-region heights. In the ion chemistry model, ion-pair production rates are calculated for solar X-rays between 1 A and 100 A, EUV radiations from 100 A up to the Lyman-alpha line, precipitating electrons, and galactic cosmic rays. The solar zenith angle variation of the positive-ion composition, negative-ion composition, and the electron densities are described up to 75 deg zenith angle, in the height interval between 60 and 100 km.
Geffré, Anne; Concordet, Didier; Braun, Jean-Pierre; Trumel, Catherine
2011-03-01
International recommendations for determination of reference intervals have been recently updated, especially for small reference sample groups, and use of the robust method and Box-Cox transformation is now recommended. Unfortunately, these methods are not included in most software programs used for data analysis by clinical laboratories. We have created a set of macroinstructions, named Reference Value Advisor, for use in Microsoft Excel to calculate reference limits applying different methods. For any series of data, Reference Value Advisor calculates reference limits (with 90% confidence intervals [CI]) using a nonparametric method when n≥40 and by parametric and robust methods from native and Box-Cox transformed values; tests normality of distributions using the Anderson-Darling test and outliers using Tukey and Dixon-Reed tests; displays the distribution of values in dot plots and histograms and constructs Q-Q plots for visual inspection of normality; and provides minimal guidelines in the form of comments based on international recommendations. The critical steps in determination of reference intervals are correct selection of as many reference individuals as possible and analysis of specimens in controlled preanalytical and analytical conditions. Computing tools cannot compensate for flaws in selection and size of the reference sample group and handling and analysis of samples. However, if those steps are performed properly, Reference Value Advisor, available as freeware at http://www.biostat.envt.fr/spip/spip.php?article63, permits rapid assessment and comparison of results calculated using different methods, including currently unavailable methods. This allows for selection of the most appropriate method, especially as the program provides the CI of limits. It should be useful in veterinary clinical pathology when only small reference sample groups are available. ©2011 American Society for Veterinary Clinical Pathology.
Karita, Etienne; Ketter, Nzeera; Price, Matt A; Kayitenkore, Kayitesi; Kaleebu, Pontiano; Nanvubya, Annet; Anzala, Omu; Jaoko, Walter; Mutua, Gaudensia; Ruzagira, Eugene; Mulenga, Joseph; Sanders, Eduard J; Mwangome, Mary; Allen, Susan; Bwanika, Agnes; Bahemuka, Ubaldo; Awuondo, Ken; Omosa, Gloria; Farah, Bashir; Amornkul, Pauli; Birungi, Josephine; Yates, Sarah; Stoll-Johnson, Lisa; Gilmour, Jill; Stevens, Gwynn; Shutes, Erin; Manigart, Olivier; Hughes, Peter; Dally, Len; Scott, Janet; Stevens, Wendy; Fast, Pat; Kamali, Anatoli
2009-01-01
Clinical laboratory reference intervals have not been established in many African countries, and non-local intervals are commonly used in clinical trials to screen and monitor adverse events (AEs) among African participants. Using laboratory reference intervals derived from other populations excludes potential trial volunteers in Africa and makes AE assessment challenging. The objective of this study was to establish clinical laboratory reference intervals for 25 hematology, immunology and biochemistry values among healthy African adults typical of those who might join a clinical trial. Equal proportions of men and women were invited to participate in a cross sectional study at seven clinical centers (Kigali, Rwanda; Masaka and Entebbe, Uganda; two in Nairobi and one in Kilifi, Kenya; and Lusaka, Zambia). All laboratories used hematology, immunology and biochemistry analyzers validated by an independent clinical laboratory. Clinical and Laboratory Standards Institute guidelines were followed to create study consensus intervals. For comparison, AE grading criteria published by the U.S. National Institute of Allergy and Infectious Diseases Division of AIDS (DAIDS) and other U.S. reference intervals were used. 2,990 potential volunteers were screened, and 2,105 (1,083 men and 1,022 women) were included in the analysis. While some significant gender and regional differences were observed, creating consensus African study intervals from the complete data was possible for 18 of the 25 analytes. Compared to reference intervals from the U.S., we found lower hematocrit and hemoglobin levels, particularly among women, lower white blood cell and neutrophil counts, and lower amylase. Both genders had elevated eosinophil counts, immunoglobulin G, total and direct bilirubin, lactate dehydrogenase and creatine phosphokinase, the latter being more pronounced among women. When graded against U.S. -derived DAIDS AE grading criteria, we observed 774 (35.3%) volunteers with grade one or higher results; 314 (14.9%) had elevated total bilirubin, and 201 (9.6%) had low neutrophil counts. These otherwise healthy volunteers would be excluded or would require special exemption to participate in many clinical trials. To accelerate clinical trials in Africa, and to improve their scientific validity, locally appropriate reference ranges should be used. This study provides ranges that will inform inclusion criteria and evaluation of adverse events for studies in these regions of Africa.
Flint, Mark; Matthews, Beren J; Limpus, Colin J; Mills, Paul C
2015-01-01
Biochemical and haematological parameters are increasingly used to diagnose disease in green sea turtles. Specific clinical pathology tools, such as plasma protein electrophoresis analysis, are now being used more frequently to improve our ability to diagnose disease in the live animal. Plasma protein reference intervals were calculated from 55 clinically healthy green sea turtles using pulsed field electrophoresis to determine pre-albumin, albumin, α-, β- and γ-globulin concentrations. The estimated reference intervals were then compared with data profiles from clinically unhealthy turtles admitted to a local wildlife hospital to assess the validity of the derived intervals and identify the clinically useful plasma protein fractions. Eighty-six per cent {19 of 22 [95% confidence interval (CI) 65-97]} of clinically unhealthy turtles had values outside the derived reference intervals, including the following: total protein [six of 22 turtles or 27% (95% CI 11-50%)], pre-albumin [two of five, 40% (95% CI 5-85%)], albumin [13 of 22, 59% (95% CI 36-79%)], total albumin [13 of 22, 59% (95% CI 36-79%)], α- [10 of 22, 45% (95% CI 24-68%)], β- [two of 10, 20% (95% CI 3-56%)], γ- [one of 10, 10% (95% CI 0.3-45%)] and β-γ-globulin [one of 12, 8% (95% CI 0.2-38%)] and total globulin [five of 22, 23% (8-45%)]. Plasma protein electrophoresis shows promise as an accurate adjunct tool to identify a disease state in marine turtles. This study presents the first reference interval for plasma protein electrophoresis in the Indo-Pacific green sea turtle.
Interior. Storage room for glassware and reference room with frequentlyused ...
Interior. Storage room for glassware and reference room with frequently-used chemistry and chemical engineering texts. - Thomas A. Edison Laboratories, Building No. 2, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
Mass Spectrometry of the CO2 Laser Plasma.
1981-06-01
Lasers Plasma Chemistry Discharge Electrochemistry 20. ABSTRACT (Continue on reverse side If necessary end identify by block number) ... The neutral and...Reference 3). The evidence indicates that valuable information concerning the plasma chemistry of the discharge can be obtained with the aid of a mass...gives very reliable results as will be shown later. The ultimate goal of this project was to investigate the plasma chemistry of the CO2 laser discharge
Tohidi, Maryam; Ghasemi, Asghar; Hadaegh, Farzad; Derakhshan, Arash; Chary, Abdolreza; Azizi, Fereidoun
2014-04-01
Increased insulin concentration is a surrogate for insulin resistance and early assessment of fasting insulin may help in identifying those who are potentially at high risk of type 2 diabetes, hypertension, and cardiovascular disease. The aim of this study was to determine age- and sex-related reference values for serum insulin and insulin resistance/sensitivity indices in Iranian subjects. Serum insulin levels were measured by electrochemiluminescence immunoassay in 5786 participants of the Tehran Lipid and Glucose Study. After application of exclusion criteria, 309 non-obese healthy subjects (124 men and 185 women), aged 24-83 y, were included. The International Federation of Clinical Chemistry guidelines (non-parametric method) and the robust method were used for determining reference values. Overall 95% reference values for fasting insulin were 1.61-11.37, 2.34-11.98, and 2.11-12.49 μU/mL in men, women, and total population respectively. Mean fasting insulin concentration showed a decreasing trend with age in both genders (p for trend ≤0.001). Age, waist circumference, and systolic blood pressures were biological determinants of fasting insulin in both genders; in addition, insulin was modulated by triglycerides in men and fasting glucose in women. Reference intervals for HOMA1-IR, HOMA2-IR, and QUICKI were 0.63-2.68, 0.40-1.80, and 0.33-0.42, respectively. This study presents the first set of reference values for fasting serum insulin to be 2-12 μU/mL for both genders in a healthy sample of Iranian adults along with the reference values for insulin resistance/sensitivity indices. These values could be used for identifying subjects with insulin resistance in epidemiological and clinical research. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Blood plasma chemistries from wild mourning doves held in captivity.
Schulz, J H; Bermudez, A J; Tomlinson, J L; Firman, J D; He, Z
2000-07-01
Despite the extensive amount of research conducted on mourning doves (Zenaida macroura), no biochemical reference values exist for this species. Our objective, therefore, was to establish base line clinical chemistry reference values for mourning doves to assist with establishing clinical diagnoses. Wild mourning doves were captured 19 March 1996 to 8 August 1996, and 6 February 1998 to 12 May 1998; blood samples were collected from 382 mourning doves. Plasma biochemical values were established for glucose, sodium, potassium, chloride, enzymatic CO2, albumin, total protein, globulin, calcium, phosphorus, cholesterol, magnesium, aspartate aminotransferase (AST), gamma glutamyl transferase (GGT), lactate dehydrogenase (LDH), and uric acid. These reference values are invaluable for determining diagnosis of diseases of the gastrointestinal, hepatic, renal, cardiovascular, musculoskeletal, and endocrine systems.
[Investigation of reference intervals of blood gas and acid-base analysis assays in China].
Zhang, Lu; Wang, Wei; Wang, Zhiguo
2015-10-01
To investigate and analyze the upper and lower limits and their sources of reference intervals in blood gas and acid-base analysis assays. The data of reference intervals were collected, which come from the first run of 2014 External Quality Assessment (EQA) program in blood gas and acid-base analysis assays performed by National Center for Clinical Laboratories (NCCL). All the abnormal values and errors were eliminated. Data statistics was performed by SPSS 13.0 and Excel 2007 referring to upper and lower limits of reference intervals and sources of 7 blood gas and acid-base analysis assays, i.e. pH value, partial pressure of carbon dioxide (PCO2), partial pressure of oxygen (PO2), Na+, K+, Ca2+ and Cl-. Values were further grouped based on instrument system and the difference between each group were analyzed. There were 225 laboratories submitting the information on the reference intervals they had been using. The three main sources of reference intervals were National Guide to Clinical Laboratory Procedures [37.07% (400/1 079)], instructions of instrument manufactures [31.23% (337/1 079)] and instructions of reagent manufactures [23.26% (251/1 079)]. Approximately 35.1% (79/225) of the laboratories had validated the reference intervals they used. The difference of upper and lower limits in most assays among 7 laboratories was moderate, both minimum and maximum (i.e. the upper limits of pH value was 7.00-7.45, the lower limits of Na+ was 130.00-156.00 mmol/L), and mean and median (i.e. the upper limits of K+ was 5.04 mmol/L and 5.10 mmol/L, the upper limits of PCO2 was 45.65 mmHg and 45.00 mmHg, 1 mmHg = 0.133 kPa), as well as the difference in P2.5 and P97.5 between each instrument system group. It was shown by Kruskal-Wallis method that the P values of upper and lower limits of all the parameters were lower than 0.001, expecting the lower limits of Na+ with P value 0.029. It was shown by Mann-Whitney that the statistic differences were found among instrument system groups and between most of two instrument system groups in all assays. The difference of reference intervals of blood gas and acid-base analysis assays used in China laboratories is moderate, which is better than other specialties in clinical laboratories.
2011-01-01
Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods. PMID:21477356
Yan, Cunling; Yang, Jia; Wei, Lianhua; Hu, Jian; Song, Jiaqi; Wang, Xiaoqin; Han, Ruilin; Huang, Ying; Zhang, Wei; Soh, Andrew; Beshiri, Agim; Fan, Zhuping; Zheng, Yijie; Chen, Wei
2018-02-01
Alpha-fetoprotein (AFP) has been widely used in clinical practice for decades. However, large-scale survey of serum reference interval for ARCHITECT AFP is still absent in Chinese population. This study aimed to measure serum AFP levels in healthy Chinese Han subjects, which is a sub-analysis of an ongoing prospective, cross-sectional, multi-center study (ClinicalTrials.gov Identifier: NCT03047603). This analysis included a total of 530 participants (41.43±12.14years of age on average, 48.49% males), enrolled from 5 regional centers. Serum AFP level was measured by ARCHITECT immunoassay. Statistical analysis was performed using SAS 9.4 and R software. AFP distribution did not show significant correlation with age or sex. The overall median and interquartile range of AFP was 2.87 (2.09, 3.83) ng/mL. AFP level did not show a trend of increasing with age. The new reference interval was 2.0-7.07ng/mL (LOQ- 97.5th percentiles). The reference interval for ARCHITECT AFP is updated with the data of adequate number of healthy Han adults. This new reference interval is more practical and applicable in Chinese adults. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Dickson, D; Shave, R; Rishniw, M; Patteson, M
2017-08-01
To establish reference intervals for echocardiographic measures of longitudinal left ventricular function in adult English Springer spaniel (ESS) dogs. This study involved 42 healthy adult ESS. Animals were prospectively recruited from a general practice population in the United Kingdom. Dogs were examined twice, at least 12 months apart, to exclude dogs with progressive cardiac disease. Mitral annular plane systolic excursion, tissue Doppler imaging mitral annular velocities and two-dimensional speckle-tracking echocardiographic left ventricular longitudinal strain and strain rate were measured. Intraoperator and intraobserver variability were examined and reference intervals were calculated. The potential effects of body weight, age and heart rate on these variables were examined. Intraoperator and intraobserver variability was <10% for all parameters except tissue Doppler imaging E' (the peak velocity of early diastolic mitral annular motion as determined by pulsed wave Doppler) and two-dimensional speckle-tracking echocardiographic variables, which were all <20%. Thirty-nine dogs were used to create reference intervals. Significant (but mostly weak) effects of age, heart rate and body weight on were detected. Reference intervals were similar to previously published values in different breeds. Breed specific reference intervals for measures of longitudinal left ventricular function in the ESS are presented. Copyright © 2017 Elsevier B.V. All rights reserved.
Piaget and School Chemistry--A Critique
ERIC Educational Resources Information Center
Jenkins, E. W.
1978-01-01
Examines Piaget's theory of cognitive development with particular reference to the teaching of chemistry in the secondary school. Concludes that the theory has many fundamental weaknesses, with respect to analyzing curriculum materials in terms of levels of thought and should not be used as the basis for course assessment. (GA)
The Chemistry of Optical Discs.
ERIC Educational Resources Information Center
Birkett, David
2002-01-01
Explains the chemistry used in compact discs (CD), digital versatile discs (DVD), and magneto-optical (MO) discs focusing on the steps of initial creation of the mold, the molding of the polycarbonate, the deposition of the reflective layers, the lacquering of the CDs, and the bonding of DVDs. (Contains 15 references.) (YDS)
A Natural Documentation Retrieval System for Macromolecular Chemistry
ERIC Educational Resources Information Center
Ulbrich, Raimund; Wierer, Jutta
1972-01-01
An indexing system for chemistry and technology of macromolecular substances is sketched out, whose characteristics are convenience of use and low cost. The selection mechanism consists of a set of optical coincidence cards. The selection is a result of 15 years experience in the German Plastics Institute. (13 references) (Author)
Green Chemistry Metrics with Special Reference to Green Analytical Chemistry.
Tobiszewski, Marek; Marć, Mariusz; Gałuszka, Agnieszka; Namieśnik, Jacek
2015-06-12
The concept of green chemistry is widely recognized in chemical laboratories. To properly measure an environmental impact of chemical processes, dedicated assessment tools are required. This paper summarizes the current state of knowledge in the field of development of green chemistry and green analytical chemistry metrics. The diverse methods used for evaluation of the greenness of organic synthesis, such as eco-footprint, E-Factor, EATOS, and Eco-Scale are described. Both the well-established and recently developed green analytical chemistry metrics, including NEMI labeling and analytical Eco-scale, are presented. Additionally, this paper focuses on the possibility of the use of multivariate statistics in evaluation of environmental impact of analytical procedures. All the above metrics are compared and discussed in terms of their advantages and disadvantages. The current needs and future perspectives in green chemistry metrics are also discussed.
Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel
2016-05-01
-The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.
Smith, Daniel G A; Burns, Lori A; Sirianni, Dominic A; Nascimento, Daniel R; Kumar, Ashutosh; James, Andrew M; Schriber, Jeffrey B; Zhang, Tianyuan; Zhang, Boyi; Abbott, Adam S; Berquist, Eric J; Lechner, Marvin H; Cunha, Leonardo A; Heide, Alexander G; Waldrop, Jonathan M; Takeshita, Tyler Y; Alenaizan, Asem; Neuhauser, Daniel; King, Rollin A; Simmonett, Andrew C; Turney, Justin M; Schaefer, Henry F; Evangelista, Francesco A; DePrince, A Eugene; Crawford, T Daniel; Patkowski, Konrad; Sherrill, C David
2018-06-11
Psi4NumPy demonstrates the use of efficient computational kernels from the open-source Psi4 program through the popular NumPy library for linear algebra in Python to facilitate the rapid development of clear, understandable Python computer code for new quantum chemical methods, while maintaining a relatively low execution time. Using these tools, reference implementations have been created for a number of methods, including self-consistent field (SCF), SCF response, many-body perturbation theory, coupled-cluster theory, configuration interaction, and symmetry-adapted perturbation theory. Furthermore, several reference codes have been integrated into Jupyter notebooks, allowing background, underlying theory, and formula information to be associated with the implementation. Psi4NumPy tools and associated reference implementations can lower the barrier for future development of quantum chemistry methods. These implementations also demonstrate the power of the hybrid C++/Python programming approach employed by the Psi4 program.
Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M
2017-01-01
Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.
Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D
2017-11-01
Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.
Adult Hematology and Clinical Chemistry Laboratory Reference Ranges in a Zimbabwean Population.
Samaneka, Wadzanai P; Mandozana, Gibson; Tinago, Willard; Nhando, Nehemiah; Mgodi, Nyaradzo M; Bwakura-Dangarembizi, Mutsawashe F; Munjoma, Marshall W; Gomo, Zvenyika A R; Chirenje, Zvavahera M; Hakim, James G
2016-01-01
Laboratory reference ranges used for clinical care and clinical trials in various laboratories in Zimbabwe were derived from textbooks and research studies conducted more than ten years ago. Periodic verification of these ranges is essential to track changes over time. The purpose of this study was to establish hematology and chemistry laboratory reference ranges using more rigorous methods. A community-based cross-sectional study was carried out in Harare, Chitungwiza, and Mutoko. A multistage sampling technique was used. Samples were transported from the field for analysis at the ISO15189 certified University of Zimbabwe-University of California San Francisco Central Research Laboratory. Hematology and clinical chemistry reference ranges lower and upper reference limits were estimated at the 2.5th and 97.5th percentiles respectively. A total of 769 adults (54% males) aged 18 to 55 years were included in the analysis. Median age was 28 [IQR: 23-35] years. Males had significantly higher red cell counts, hemoglobin, hematocrit, and mean corpuscular hemoglobin compared to females. Females had higher white cell counts, platelets, absolute neutrophil counts, and absolute lymphocyte counts compared to males. There were no gender differences in eosinophils, monocytes, and absolute basophil count. Males had significantly higher levels of urea, sodium, potassium, calcium, creatinine, amylase, total protein, albumin and liver enzymes levels compared to females. Females had higher cholesterol and lipase compared with males. There are notable differences in the white cell counts, neutrophils, cholesterol, and creatinine kinase when compared with the currently used reference ranges. Data from this study provides new country specific reference ranges which should be immediately adopted for routine clinical care and accurate monitoring of adverse events in research studies.
Loh, Tze Ping; Sethi, Sunil Kumar; Metz, Michael Patrick
2015-08-01
To describe the reference intervals and biological variation data for thyrotropin (TSH) and free thyroxine (FT4) in a mixed Asian population using an indirect sampling approach and to compare them with published reports. TSH and FT4 of children measured once or twice over a 7-year period (2008-2014) at primary-care and tertiary-care settings were extracted from the laboratory information system. After excluding outliers, age-related reference intervals were derived using the Lambda-Mu-Sigma (LMS) approach, while age-partitioned biological variation data were obtained according to recommendations by Fraser and Harris. Both TSH and FT4 were very high at birth and declined with age. Similarly within-individual and between-individual biological variations were higher for both TSH and FT4 at birth and also declined with age. Our data were broadly similar to previous studies. Significant heterogeneity in study population and methods prohibited direct numerical comparison between this and previously published studies. This study fills two important gaps in our knowledge of paediatric thyroid function by reporting the centile trends (and reference values) in a mixed Asian population, as well as providing age-partitioned biological variation data. The variation in published reference intervals highlights the difficulty in harmonising paediatric thyroid reference intervals or recommending universal clinical cut-offs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Flint, Mark; Matthews, Beren J.; Limpus, Colin J.; Mills, Paul C.
2015-01-01
Biochemical and haematological parameters are increasingly used to diagnose disease in green sea turtles. Specific clinical pathology tools, such as plasma protein electrophoresis analysis, are now being used more frequently to improve our ability to diagnose disease in the live animal. Plasma protein reference intervals were calculated from 55 clinically healthy green sea turtles using pulsed field electrophoresis to determine pre-albumin, albumin, α-, β- and γ-globulin concentrations. The estimated reference intervals were then compared with data profiles from clinically unhealthy turtles admitted to a local wildlife hospital to assess the validity of the derived intervals and identify the clinically useful plasma protein fractions. Eighty-six per cent {19 of 22 [95% confidence interval (CI) 65–97]} of clinically unhealthy turtles had values outside the derived reference intervals, including the following: total protein [six of 22 turtles or 27% (95% CI 11–50%)], pre-albumin [two of five, 40% (95% CI 5–85%)], albumin [13 of 22, 59% (95% CI 36–79%)], total albumin [13 of 22, 59% (95% CI 36–79%)], α- [10 of 22, 45% (95% CI 24–68%)], β- [two of 10, 20% (95% CI 3–56%)], γ- [one of 10, 10% (95% CI 0.3–45%)] and β–γ-globulin [one of 12, 8% (95% CI 0.2–38%)] and total globulin [five of 22, 23% (8–45%)]. Plasma protein electrophoresis shows promise as an accurate adjunct tool to identify a disease state in marine turtles. This study presents the first reference interval for plasma protein electrophoresis in the Indo-Pacific green sea turtle. PMID:27293722
Andreasen, C B; Pearson, E G; Smith, B B; Gerros, T C; Lassen, E D
1998-04-01
Fifty clinically healthy llamas, 0.5-13 years of age (22 intact males, 10 neutered males, 18 females), with no biochemical evidence of liver disease or hematologic abnormalities, were selected to establish serum bile acid reference intervals. Serum samples submitted to the clinical pathology laboratory were analyzed using a colorimetric enzymatic assay to establish bile acid reference intervals. A nonparametric distribution of llama bile acid concentrations was 1-23 micromol/liter for llamas >1 year of age and 10-44 micromol/liter for llamas < or = 1 year of age. A significant difference was found between these 2 age groups. No correlation was detected between gender and bile acid concentrations. The reference intervals were 1.1-22.9 micromol/liter for llamas >1 year of age and 1.8-49.8 micromol/liter for llamas < or = 1 year of age. Additionally, a separate group of 10 healthy adult llamas (5 males, 5 females, 5-11 years of age) without biochemical or hematologic abnormalities was selected to assess the effects of feeding and time intervals on serum bile acid concentrations. These 10 llamas were provided fresh water and hay ad libitum, and serum samples were obtained via an indwelling jugular catheter hourly for 11 hours. Llamas were then kept from food overnight (12 hours), and subsequent samples were taken prior to feeding (fasting baseline time, 23 hours after trial initiation) and postprandially at 0.5, 1, 2, 4, and 8 hours. In feeding trials, there was no consistent interaction between bile acid concentrations and time, feeding, or 12-hour fasting. Prior feeding or time of day did not result in serum bile acid concentrations outside the reference interval, but concentrations from individual llamas varied within this interval over time.
Reference intervals for urinary renal injury biomarkers KIM-1 and NGAL in healthy children
McWilliam, Stephen J; Antoine, Daniel J; Sabbisetti, Venkata; Pearce, Robin E; Jorgensen, Andrea L; Lin, Yvonne; Leeder, J Steven; Bonventre, Joseph V; Smyth, Rosalind L; Pirmohamed, Munir
2014-01-01
Aim The aim of this study was to establish reference intervals in healthy children for two novel urinary biomarkers of acute kidney injury, kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL). Materials & Methods Urinary biomarkers were determined in samples from children in the UK (n = 120) and the USA (n = 171) using both Meso Scale Discovery (MSD) and Luminex-based analytical approaches. Results 95% reference intervals for each biomarker in each cohort are presented and stratified by sex or ethnicity where necessary, and age-related variability is explored using quantile regression. We identified consistently higher NGAL concentrations in females than males (p < 0.0001), and lower KIM-1 concentrations in African–Americans than Caucasians (p = 0.02). KIM-1 demonstrated diurnal variation, with higher concentrations in the morning (p < 0.001). Conclusion This is the first report of reference intervals for KIM-1 and NGAL using two analytical methods in a healthy pediatric population in both UK and US-based populations. PMID:24661102
Evaluation of an anal sac adenocarcinoma tumor in a Spitz dog
Javanbakht, Javad; Tavassoli, Abbas; Sabbagh, Atefeh; Hassan, Mehdy Aghamohammmad; Samakkhah, Shohreh Alian; Shafiee, Radmehr; Lakzian, Ali; Ghalee, Vahideh Rahmani; Gharebagh, Sonia Shoja
2013-01-01
A 9-year-old emasculated male Spitz with tenesmus and constipation had a subcutaneous mass at the left ventral aspect of the anus with history of polyuria and polydipsia. A complete blood cell count, serum biochemistry panel, and urinalysis (cystocentesis sample) were evaluated. Abnormalities in the serum biochemistry panel included a mildly elevated serum cholesterol concentration (7.28 mmol/L; reference interval, 2.70–5.94 mmol/L), increased serum alkaline phosphatase activity (184 U/L; reference interval, 9–90 U/L), alanine transaminase (122 U/L; reference interval, 5–60 U/L) activity and aspartate aminotransferase (80 U/L; reference interval, 5–55 U/L) activity, severe increased total calcium concentration (16.3 mg/dL; reference interval, 8.2–12.4 mg/dL or 9.3–11.4 mg/dL), and decreased total calcium concentration (3.4 mg/dL, reference interval, 2.5–5.6mg/dL). Furthermore, testing revealed an increased intact parathyroid hormone concentration (38.6 pmol/L; reference interval, 3–17 pmol/L). On cytologic and histopathologic examinations, various types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Based on location and histologic features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs. PMID:23570021
Hannemann, Anke; Friedrich, Nele; Spielhagen, Christin; Rettig, Rainer; Ittermann, Till; Nauck, Matthias; Wallaschofski, Henri
2013-03-13
Osteocalcin (OC) is a bone-specific protein produced primarily by osteoblasts during bone formation. Besides its role in bone formation, osteocalcin may play a role in the regulation of energy metabolism and male fertility. To interpret serum OC data, reference intervals adapted to a specific laboratory method are needed. A healthy reference population was selected from the first follow-up of the Study of Health in Pomerania. Serum OC concentrations were measured with the IDS-iSYS N-Mid Osteocalcin assay on the IDS-iSYS Automated System (Immunodiagnostic Systems, Frankfurt am Main, Germany). The reference interval was defined as the central 95% range (2.5th-97.5th percentile). Age-specific reference intervals were calculated by quantile regression for 1107 men (25-79 years) and 545 premenopausal women (25-54 years). The reference interval for 498 postmenopausal women (50-79 years) was calculated irrespective of age. Median (1st-3rd quartile) serum OC concentrations were 15.4 ng/mL (12.0-19.4 ng/mL) in men, 14.4 ng/mL (11.3-18.5 ng/mL) in premenopausal women, and 18.6 ng/mL (13.6-25.6 ng/mL) in postmenopausal women. Serum OC concentrations were highest in men and premenopausal women aged 25-29 years, were stable during midlife, and rose again after 65 years of age in men and at transition to menopause in women. Serum OC concentrations were lower in women taking oral contraceptives or who were under hormone replacement therapy after menopause and in subjects with diabetes mellitus or with body mass index < 18 or > 30 kg/m2 than in subjects without these conditions. We established sex-specific adult reference intervals for the serum OC concentration measured by the IDS-iSYS N-Mid Osteocalcin assay.
Presentation of Atomic Structure in Turkish General Chemistry Textbooks
ERIC Educational Resources Information Center
Niaz, Mansoor; Costu, Bayram
2009-01-01
Research in science education has recognized the importance of teaching atomic structure within a history and philosophy of science perspective. The objective of this study is to evaluate general chemistry textbooks published in Turkey based on the eight criteria developed in previous research. Criteria used referred to the atomic models of…
The Chemistry of Paper Preservation Part 4. Alkaline Paper.
ERIC Educational Resources Information Center
Carter, Henry A.
1997-01-01
Discusses the problem of the inherent instability of paper due to the presence of acids that catalyze the hydrolytic degradation of cellulose. Focuses on the chemistry involved in the sizing of both acid and alkaline papers and the types of fillers used. Discusses advantages and problems of alkaline papermaking. Contains 48 references. (JRH)
NASA Technical Reports Server (NTRS)
Gammon, R. H.
1976-01-01
A unit is presented for the secondary school teacher of physics, chemistry, astronomy, or earth sciences. Included are a list of reference materials, teaching aids, and projects. Discussion questions and a glossary are also provided. Concepts developed are: the nature of interstellar space, spectroscopy, molecular signals from space and interstellar molecules and other areas of astronomy.
Identification of unknowns in non-targeted analyses (NTA) requires the integration of complementary data types to generate a confident consensus structure. Researchers use a variety of data and tools (e.g., chemical reference databases, spectral matching, fragment prediction too...
How To Use Crystallographic Information in Teaching First-Year Chemistry.
ERIC Educational Resources Information Center
Bevan, D. J. M.; And Others
1988-01-01
Emphasizes the role that crystallography plays and has played in building up the body of chemical fact. Shows how the teaching of much of this material is illuminated by reference to crystal structures and crystallochemical relationships in all areas of chemistry. Discusses close packing, silicate structures, and salt hydrates. (CW)
The Oil Drop Experiment: Do Physical Chemistry Textbooks Refer to Its Controversial Nature?
ERIC Educational Resources Information Center
Niaz, Mansoor; Rodriguez, Maria A.
2005-01-01
Most general chemistry textbooks consider the oil drop experiment as a classic experiment, characterized by its simplicity and precise results. A review of the history and philosophy of science literature shows that the experiment is difficult to perform (even today!) and generated a considerable amount of controversy. Acceptance of the…
Magic, science and masculinity: marketing toy chemistry sets.
Al-Gailani, Salim
2009-12-01
At least since the late nineteenth century, toy chemistry sets have featured in standard scripts of the achievement of eminence in science, and they remain important in constructions of scientific identity. Using a selection of these toys manufactured in Britain and the United States, and with particular reference to the two dominant American brands, Gilbert and Chemcraft, this paper suggests that early twentieth-century chemistry sets were rooted in overlapping Victorian traditions of entertainment magic and scientific recreations. As chemistry set marketing copy gradually reoriented towards emphasising scientific modernity, citizenship, discipline and educational value, pre-twentieth-century traditions were subsumed within domestic-and specifically masculine-tropes. These developments in branding strategies point to transformations in both users' engagement with their chemistry sets and the role of scientific toys in domestic play. The chemistry set serves here as a useful tool for measuring cultural change and lay engagement with chemistry.
Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes
2017-09-01
Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.
Acea Nebril, B; Figueira Moure, A; Gómez Freijoso, C
2000-09-01
To study changes in authorship, interval between acceptance and publication, and bibliographic references of original articles published in Revista Española de Enfermedades Digestivas (REED) between 1993 and 1998. This was a descriptive retrospective study of 359 original research articles published in REED between 1993 and 1998. The variables assessed were: number of authors (author/article index), interval between acceptance of the manuscript and publication in the journal, and degree of obsolescence of articles based on the age of the references cited (Burton-Kleber and Price indexes). The author/article index was 6.1, and increased from 5.9 in 1993 to 6.5 in 1998. The interval between acceptance and publication increased from 251 days to 436 days in this period (p < 0.0001). English was the language of publication used most commonly, followed by Spanish (10.7%). Citations to Spanish references decreased from 12.5% in 1993 to 8.7% in 1998. The half-life of articles was 7 years, and Price index was 41.5%. REED's bibliometric characteristics are similar to those of other national journals, but this study shows changes in bibliographic indicators from 1993 to 1998; increases in the number of authors per article, the interval to publication, the use of foreign references and the degree of obsolescence.
ERIC Educational Resources Information Center
Briscoe, Carol
1993-01-01
Study suggests that cognitive referents are important influences in how a teacher thinks about assessment and may constrain a teacher's implementation of innovative practices. Identification of referents such as myths, their associated beliefs, and metonymic conceptual models that teachers use to make sense of their actions is an important step in…
Josman, Nicky; Tee, Nancy W S; Maiwald, Matthias; Loo, Liat Hui; Ho, Clement K M
2018-06-15
It is often impractical for each laboratory to establish its own paediatric reference intervals. This is particularly true for specimen types collected using invasive procedures, for example, cerebrospinal fluid (CSF). Published CSF reference intervals for white cell count, and concentrations of total protein and glucose were reviewed by stakeholders in a paediatric hospital. Consensus reference intervals for the three CSF parameters were then subjected to verification using guidelines from the Clinical Laboratory Standards Institute and residual CSF specimens. Consensus paediatric reference intervals adapted from published studies with minor modifications were locally verified as follows. White cell count (x10 6 cells/L): 0-20 (<1 month); 0-10 (1-2 months); 0-5 (>2 months). Total protein (g/L): 0.3-1.2 (<1 month); 0.2-0.6 (1-3 months); 0.1-0.4 (>3 months). Glucose (mmol/L): 2.0-5.6 (<6 months); 2.4-4.3 (6 months or older). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Franson, J. Christian; Flint, Paul L.; Schmutz, Joel A.
2017-01-01
We determined reference intervals for nine serum biochemistries in samples from 329 molting, after-hatch-year, Pacific Black Brant (Branta bernicla nigricans) in Alaska, US. Cholesterol and nonesterified fatty acids differed by sex, but no other differences were noted.
Identifying known unknowns using the US EPA's CompTox Chemistry Dashboard.
McEachran, Andrew D; Sobus, Jon R; Williams, Antony J
2017-03-01
Chemical features observed using high-resolution mass spectrometry can be tentatively identified using online chemical reference databases by searching molecular formulae and monoisotopic masses and then rank-ordering of the hits using appropriate relevance criteria. The most likely candidate "known unknowns," which are those chemicals unknown to an investigator but contained within a reference database or literature source, rise to the top of a chemical list when rank-ordered by the number of associated data sources. The U.S. EPA's CompTox Chemistry Dashboard is a curated and freely available resource for chemistry and computational toxicology research, containing more than 720,000 chemicals of relevance to environmental health science. In this research, the performance of the Dashboard for identifying known unknowns was evaluated against that of the online ChemSpider database, one of the primary resources used by mass spectrometrists, using multiple previously studied datasets reported in the peer-reviewed literature totaling 162 chemicals. These chemicals were examined using both applications via molecular formula and monoisotopic mass searches followed by rank-ordering of candidate compounds by associated references or data sources. A greater percentage of chemicals ranked in the top position when using the Dashboard, indicating an advantage of this application over ChemSpider for identifying known unknowns using data source ranking. Additional approaches are being developed for inclusion into a non-targeted analysis workflow as part of the CompTox Chemistry Dashboard. This work shows the potential for use of the Dashboard in exposure assessment and risk decision-making through significant improvements in non-targeted chemical identification. Graphical abstract Identifying known unknowns in the US EPA's CompTox Chemistry Dashboard from molecular formula and monoisotopic mass inputs.
Verma, Mascha; Khadapkar, Rashmi; Sahu, Priyadarshi Soumyaranjan; Das, Bibhu Ranjan
2006-09-01
An increase in the communication within the healthcare services, both nationally and internationally, has strengthened the need for harmonization of measurements and reference intervals in laboratory medicine. In the present report, the calculated reference interval for serum creatinine (sCr) levels of healthy normal individuals (n=1121) in different sex and age groups are compared with the established interval. The calculated reference interval for sCr level was 0.4-1.3 mg/dL and 0.6 to 1.3 mg/dL in the age groups of 21-40 and 41-60 years respectively. The difference between the mean sCr values in total males and total females (age range 21-60 years) was statistically significant (p<0.0001); When male and female subjects were analyzed age-group wise, the data showed a significant difference in mean sCr values (p<0.0001) in three age groups (21-30, 31-40 and 41-50 years) however, in older age group (51-60 years), the difference was non-significant (p=0.07). The reference ranges were 0.7-1.3 and 0.4-1.0 mg/dL for males and females respectively where the lower limit was 0.1-0.2 units less than that of standard limits. An increase in the mean value of sCr was observed particularly in females with an increase in age. Hence it is of interest to validate an age specific reference ranges for sCr in our population.
Friendship chemistry: An examination of underlying factors☆.
Campbell, Kelly; Holderness, Nicole; Riggs, Matt
2015-06-01
Interpersonal chemistry refers to a connection between two individuals that exists upon first meeting. The goal of the current study is to identify beliefs about the underlying components of friendship chemistry. Individuals respond to an online Friendship Chemistry Questionnaire containing items that are derived from interdependence theory and the friendship formation literature. Participants are randomly divided into two subsamples. A principal axis factor analysis with promax rotation is performed on subsample 1 and produces 5 factors: Reciprocal candor, mutual interest, personableness, similarity, and physical attraction. A confirmatory factor analysis is conducted using subsample 2 and provides support for the 5-factor model. Participants with agreeable, open, and conscientious personalities more commonly report experiencing friendship chemistry, as do those who are female, young, and European/white. Responses from participants who have never experienced chemistry are qualitatively analyzed. Limitations and directions for future research are discussed.
On Study of Teaching Reform of Organic Chemistry Course in Applied Chemical Industry Technology
NASA Astrophysics Data System (ADS)
Zhang, Yunshen
2017-11-01
with the implementation of new curriculum reform, the education sees great changes in teaching methods. Teaching reform is profound in organic chemistry course in applied chemical industry technology. However, many problems which have never been noticed before occur when reform programs are implemented which harm students’ ability for learning and enthusiasm in side face. This paper proposes reform measures like combining theory and practice, improving professional quality, supplementing professional needs and integrating teaching into life after analyzing organic chemistry course teaching in applied chemical industry technology currently, hoping to play a role of reference for organic chemistry course teaching reform in applied chemical industry technology.
Mehta, Ambar; Xu, Tim; Hutfless, Susan; Makary, Martin A; Sinno, Abdulrahman K; Tanner, Edward J; Stone, Rebecca L; Wang, Karen; Fader, Amanda N
2017-05-01
Hysterectomy is among the most common major surgical procedures performed in women. Approximately 450,000 hysterectomy procedures are performed each year in the United States for benign indications. However, little is known regarding contemporary US hysterectomy trends for women with benign disease with respect to operative technique and perioperative complications, and the association between these 2 factors with patient, surgeon, and hospital characteristics. We sought to describe contemporary hysterectomy trends and explore associations between patient, surgeon, and hospital characteristics with surgical approach and perioperative complications. Hysterectomies performed for benign indications by general gynecologists from July 2012 through September 2014 were analyzed in the all-payer Maryland Health Services Cost Review Commission database. We excluded hysterectomies performed by gynecologic oncologists, reproductive endocrinologists, and female pelvic medicine and reconstructive surgeons. We included both open hysterectomies and those performed by minimally invasive surgery, which included vaginal hysterectomies. Perioperative complications were defined using the Agency for Healthcare Research and Quality patient safety indicators. Surgeon hysterectomy volume during the 2-year study period was analyzed (0-5 cases annually = very low, 6-10 = low, 11-20 = medium, and ≥21 = high). We utilized logistic regression and negative binomial regression to identify patient, surgeon, and hospital characteristics associated with minimally invasive surgery utilization and perioperative complications, respectively. A total of 5660 hospitalizations were identified during the study period. Most patients (61.5%) had an open hysterectomy; 38.5% underwent a minimally invasive surgery procedure (25.1% robotic, 46.6% laparoscopic, 28.3% vaginal). Most surgeons (68.2%) were very low- or low-volume surgeons. Factors associated with a lower likelihood of undergoing minimally invasive surgery included older patient age (reference 45-64 years; 20-44 years: adjusted odds ratio, 1.16; 95% confidence interval, 1.05-1.28), black race (reference white; adjusted odds ratio, 0.70; 95% confidence interval, 0.63-0.78), Hispanic ethnicity (adjusted odds ratio, 0.62; 95% confidence interval, 0.48-0.80), smaller hospital (reference large; small: adjusted odds ratio, 0.26; 95% confidence interval, 0.15-0.45; medium: adjusted odds ratio, 0.87; 95% confidence interval, 0.79-0.96), medium hospital hysterectomy volume (reference ≥200 hysterectomies; 100-200: adjusted odds ratio, 0.78; 95% confidence interval, 0.71-0.87), and medium vs high surgeon volume (reference high; medium: adjusted odds ratio, 0.87; 95% confidence interval, 0.78-0.97). Complications occurred in 25.8% of open and 8.2% of minimally invasive hysterectomies (P < .0001). Minimally invasive hysterectomy (adjusted odds ratio, 0.22; 95% confidence interval, 0.17-0.27) and large hysterectomy volume hospitals (reference ≥200 hysterectomies; 1-100: adjusted odds ratio, 2.26; 95% confidence interval, 1.60-3.20; 101-200: adjusted odds ratio, 1.63; 95% confidence interval, 1.23-2.16) were associated with fewer complications, while patient payer, including Medicare (reference private; adjusted odds ratio, 1.86; 95% confidence interval, 1.33-2.61), Medicaid (adjusted odds ratio, 1.63; 95% confidence interval, 1.30-2.04), and self-pay status (adjusted odds ratio, 2.41; 95% confidence interval, 1.40-4.12), and very-low and low surgeon hysterectomy volume (reference ≥21 cases; 1-5 cases: adjusted odds ratio, 1.73; 95% confidence interval, 1.22-2.47; 6-10 cases: adjusted odds ratio, 1.60; 95% confidence interval, 1.11-2.23) were associated with perioperative complications. Use of minimally invasive hysterectomy for benign indications remains variable, with most patients undergoing open, more morbid procedures. Older and black patients and smaller hospitals are associated with open hysterectomy. Patient race and payer status, hysterectomy approach, and surgeon volume were associated with perioperative complications. Hysterectomies performed for benign indications by high-volume surgeons or by minimally invasive techniques may represent an opportunity to reduce preventable harm. Copyright © 2017 Elsevier Inc. All rights reserved.
Simpson, Aaron J; Potter, Julia M; Koerbin, Gus; Oakman, Carmen; Cullen, Louise; Wilkes, Garry J; Scanlan, Samuel L; Parsonage, William; Hickman, Peter E
2014-06-01
Many patients presenting to the emergency department (ED) for assessment of possible acute coronary syndrome (ACS) have low cardiac troponin concentrations that change very little on repeat blood draw. It is unclear if a lack of change in cardiac troponin concentration can be used to identify acutely presenting patients at low risk of ACS. We used the hs-cTnI assay from Abbott Diagnostics, which can detect cTnI in the blood of nearly all people. We identified a population of ED patients being assessed for ACS with repeat cTnI measurement who ultimately were proven to have no acute cardiac disease at the time of presentation. We used data from the repeat sampling to calculate total within-person CV (CV(T)) and, knowing the assay analytical CV (CV(A)), we could calculate within-person biological variation (CV(i)), reference change values (RCVs), and absolute RCV delta cTnI concentrations. We had data sets on 283 patients. Men and women had similar CV(i) values of approximately 14%, which was similar at all concentrations <40 ng/L. The biological variation was not dependent on the time interval between sample collections (t = 1.5-17 h). The absolute delta critical reference change value was similar no matter what the initial cTnI concentration was. More than 90% of subjects had a critical reference change value <5 ng/L, and 97% had values of <10 ng/L. With this hs-cTnI assay, delta cTnI seems to be a useful tool for rapidly identifying ED patients at low risk for possible ACS. © 2014 The American Association for Clinical Chemistry.
ERIC Educational Resources Information Center
de Berg, Kevin
2012-01-01
This paper reports on students' understanding of sugar concentration in aqueous solutions presented in two different modes: a visual submicroscopic mode for particles and a verbal mode referring to macroscopic amounts of sugar. One hundred and forty-five tertiary college students studying some form of first-year chemistry participated in the…
Non-traditional Oxidants in Preparative Coordination Chemistry
NASA Astrophysics Data System (ADS)
Kukushkin, Vadim Yu; Kukushkin, Yurii N.
1986-10-01
The application of nitrosonium and arenediazonium salts, carbenium, silver(I), and mercury(II) ions, protic acids, and amine oxides as oxidants in preparative coordination chemistry is examined. Specific examples illustrate which problems in the field of the synthesis and reactions of coordination compounds can be solved with the aid of these oxidants. The bibliography includes 158 references.
Testing and Extending VSEPR with WebMO and MOPAC or GAMESS
ERIC Educational Resources Information Center
McNaught, Ian J.
2011-01-01
VSEPR is a topic that is commonly taught in undergraduate chemistry courses. The readily available Web-based program WebMO, in conjunction with the computational chemistry programs MOPAC and GAMESS, is used to quantitatively test a wide range of predictions of VSEPR. These predictions refer to the point group of the molecule, including the…
NASA Astrophysics Data System (ADS)
Mendoza-Wilson, Ana María.; Lardizabal-Gutiérrez, Daniel; Torres-Moye, Enrique; Fuentes-Cobas, Luis; Balandrán-Quintana, René R.; Camacho-Dávila, Alejandro; Quintero-Ramos, Armando; Glossman-Mitnik, Daniel
2007-12-01
The purpose of this work was to evaluate the accuracy of the CHIH(medium)-DFT model chemistry (PBEg/CBSB2 ∗∗//PBEg/CBSB4) in the determination of the optimized structure and thermochemical properties of heterocyclic systems of medium size such as flavonoids, wherefore were selected three of the most abundant flavonoids in vegetable tissues, and which posses the higher antioxidant activity: quercetin, (+)-catechin and cyanidin. As reference systems were employed three cyclic compounds: phenol, catechol and resorcinol. The thermochemical properties evaluated were enthalpy of formation, bond dissociation enthalpy (BDE) and ionization potential (IP), following the scheme of isodesmic reactions. The theoretical results were compared with experimental data generated by X-ray diffraction and calorimetric techniques realized in part by us, whereas other data were taken from the literature. The results obtained in this work reveal that the CHIH(medium)-DFT model chemistry represents an accurate computational tool to calculate structural and thermochemical properties in the studied flavonoid and reference compounds. The average absolute deviation of enthalpy of formation for reference compounds was 3.0 kcal/mol, 2.64 kcal/mol for BDE, and 2.97 kcal/mol for IP.
ERIC Educational Resources Information Center
Science News, 1987
1987-01-01
Provides a review of science news stories reported in "Science News" during 1987. References each item to the volume and page number in which the subject was addressed. Contains references on astronomy, behavior, biology, biomedicine, chemistry, earth sciences, environment, mathematics and computers, paleontology and anthropology, physics, science…
Costello, Rebecca B; Elin, Ronald J; Rosanoff, Andrea; Wallace, Taylor C; Guerrero-Romero, Fernando; Hruby, Adela; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha; Song, Yiqing; Van Horn, Linda V
2016-11-01
The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75-0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. © 2016 American Society for Nutrition.
Elin, Ronald J; Rosanoff, Andrea; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha
2016-01-01
The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75–0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. PMID:28140318
Wang, Yan; Zhang, Yu-Xia; Zhou, Yong-Lie; Xia, Jun
2017-07-01
In order to establish suitable reference intervals of thyroid-stimulating hormone (TSH), free (unbound) T4 (FT4), free triiodothyronine (FT3), total thyroxine (T4), and total triiodothyronine (T3) for the patients collected in Zhejiang, China, an indirect method was developed using the data from the people presented for routine health check-up. Fifteen thousand nine hundred and fifty-six person's results were reviewed. Box-Cox or Case Rank was used to transform the data to normal distribution. Tukey and Box-Plot methods were used to exclude the outliers. Nonparametric method was used to establish the reference intervals following the EP28-A3c guideline. Pearson correlation was used to evaluate the correlation between hormone levels and age, while Mann-Whitney U test was employed for quantification of concentration differences on the people who are younger and older than 50 years old. Reference intervals were 0.66-4.95 mIU/L (TSH), 8.97-14.71 pmol/L (FT4), 3.75-5.81 pmol/L (FT3), 73.45-138.93 nmol/L (total T4), and 1.24-2.18 nmol/L (total T3) in male; conversely, reference intervals for female were 0.72-5.84 mIU/L (TSH), 8.62-14.35 pmol/L (FT4), 3.59-5.56 pmol/L (FT3), 73.45-138.93 nmol/L (total T4), and 1.20-2.10 nmol/L (total T3). FT4, FT3, and total T3 levels in male and FT4 level in female had an inverse correlation with age. Total T4 and TSH levels in female were directly correlated. Significant differences in these hormones were also found between younger and older than 50 years old except FT3 in female. Indirect method can be applied for establishment of reference intervals for TSH, FT4, FT3, total T4, and total T3. The reference intervals are narrower than those previously established. Age factor should also be considered. © 2016 Wiley Periodicals, Inc.
Hong, Seokpyo; Ahn, Kilsoo; Kim, Sungjune; Gong, Sungyong
2015-01-01
This study presents a methodology that enables a quantitative assessment of green chemistry technologies. The study carries out a quantitative evaluation of a particular case of material reutilization by calculating the level of "greenness" i.e., the level of compliance with the principles of green chemistry that was achieved by implementing a green chemistry technology. The results indicate that the greenness level was enhanced by 42% compared to the pre-improvement level, thus demonstrating the economic feasibility of green chemistry. The assessment technique established in this study will serve as a useful reference for setting the direction of industry-level and government-level technological R&D and for evaluating newly developed technologies, which can greatly contribute toward gaining a competitive advantage in the global market.
Friendship chemistry: An examination of underlying factors☆
Campbell, Kelly; Holderness, Nicole; Riggs, Matt
2015-01-01
Interpersonal chemistry refers to a connection between two individuals that exists upon first meeting. The goal of the current study is to identify beliefs about the underlying components of friendship chemistry. Individuals respond to an online Friendship Chemistry Questionnaire containing items that are derived from interdependence theory and the friendship formation literature. Participants are randomly divided into two subsamples. A principal axis factor analysis with promax rotation is performed on subsample 1 and produces 5 factors: Reciprocal candor, mutual interest, personableness, similarity, and physical attraction. A confirmatory factor analysis is conducted using subsample 2 and provides support for the 5-factor model. Participants with agreeable, open, and conscientious personalities more commonly report experiencing friendship chemistry, as do those who are female, young, and European/white. Responses from participants who have never experienced chemistry are qualitatively analyzed. Limitations and directions for future research are discussed. PMID:26097283
Norman, Stephanie A; Beckett, Laurel A; Miller, Woutrina A; St Leger, Judy; Hobbs, Roderick C
2013-06-01
Blood analytes are critical for evaluating the general health of cetacean populations, so it is important to understand the intrinsic variability of hematology and serum chemistry values. Previous studies have reported data for follow-up periods of several years in managed and wild populations, but studies over long periods of time (> 20 yr) have not been reported. The study objective was to identify the influences of partitioning characteristics on hematology and serum chemistry analytes of apparently healthy managed beluga (Delphinapterus leucas). Blood values from 31 managed belugas, at three facilities, collected over 22 yr, were assessed for seasonal variation and aging trends, and evaluated for biologic variation among and within individuals. Linear mixed effects models assessed the relationship between the analytes and sex, age, season, facility location, ambient air temperature, and photoperiod. Sex differences in analytes and associations with increasing age were observed. Seasonal variation was observed for hemoglobin, hematocrit, mean corpuscular volume, monocytes, alkaline phosphatase, total bilirubin, cholesterol, and triglycerides. Facilities were associated with larger effects on analyte values compared to other covariates, whereas age, sex, and ambient temperature had smaller effects compared to facility and season. Present findings provide important baseline information for future health monitoring efforts. Interpretation of blood analytes and animal health in managed and wild populations over time is aided by having available typical levels for the species and reference intervals for the degree to which individual animals vary from the species average and from their own baseline levels during long-term monitoring.
Galagarza, Oscar A; Kuhn, David D; Smith, Stephen A; Hrubec, Terry C
2017-09-01
Striped catfish (Pangasius hypophthalmus) is a valuable aquaculture fish species produced primarily in Southeast Asia. In the United States, it is bred as an ornamental species. Striped catfish has high productivity and great demand in numerous countries around the world, yet little is known about its normal physiology. The objective of this study was to establish hematologic and blood chemistry RIs for healthy juvenile Striped catfish. Blood samples were collected from 70 Striped catfish raised in recirculating aquaculture systems. Whole blood and plasma samples were analyzed for multiple hematologic and chemistry variables using standard techniques. The RIs for hematology were as follows: PCV 23.5-35.9%, MCV 106.3-156.6 fL, RBC count 1.79-2.75 × 10 6 cells/μL, thrombocytes 26,318-73,333 cells/μL, total WBC count 36,294-94,286 cells/μL, total lymphocytes 18,997-59,998 cells/μL, small lymphocytes 13,763-51,490 cells/μL, large lymphocytes 715-21,200 cells/μL, granulocytes 4504-18,291 cells/μL, and monocytes 0-7549 cells/μL. Plasma chemistry RIs were the following: ALP 32.7-74.6 U/L, AST 20.3-1235.8 U/L, sodium 135.2-147.7 mmol/L, potassium 3.3-5.0 mmol/L, chloride 120.1-133.6 mmol/L, calcium 2.7-3.6 mmol/L, magnesium 0.9-1.3 mmol/L, phosphorous 1.4-2.7 mmol/L, glucose 4.6-7.6 mmol/L, cholesterol 2.8-5.3 mmol/L, total protein 30-42 g/L, albumin 7-11 g/L, globulin 22-32 g/L, albumin:globulin ratio 0.27-0.37, creatinine 0-8 μmol/L, and osmolality 251.8-327.9 mOsm/kg. Reference intervals reported here can help veterinarians and fish health specialists monitor the health status of Striped catfish under recirculating aquaculture conditions for research, exhibition, and production purposes. © 2017 American Society for Veterinary Clinical Pathology.
Joosen, Annemiek M C P; van der Linden, Ivon J M; Schrauwen, Lianne; Theeuwes, Alisia; de Groot, Monique J M; Ermens, Antonius A M
2017-11-27
Vasopressin and adrenomedullin and their stable by-products copeptin and midregional part of proadrenomedullin (MR-proADM) are promising biomarkers for the development of preeclampsia. However, clinical use is hampered by the lack of trimester-specific reference intervals. We therefore estimated reference intervals for copeptin and MR-proADM in disease-free Dutch women throughout pregnancy. Apparently healthy low risk pregnant women were recruited. Exclusion criteria included current or past history of endocrine disease, multiple pregnancy, use of medication known to influence thyroid function and current pregnancy as a result of hormonal stimulation. Women who miscarried, developed hyperemesis gravidarum, hypertension, pre-eclampsia, hemolysis elevated liver enzymes and low platelets, diabetes or other disease, delivered prematurely or had a small for gestational age neonate were excluded from analyses. Blood samples were collected at 9-13 weeks (n=98), 27-29 weeks (n=94) and 36-39 weeks (n=91) of gestation and at 4-13 weeks post-partum (PP) (n=89). Sixty-two women had complete data during pregnancy and PP. All analyses were performed on a Kryptor compact plus. Copeptin increases during pregnancy, but 97.5th percentiles remain below the non-pregnant upper reference limit (URL) provided by the manufacturer. MR-proADM concentrations increase as well during pregnancy. In trimesters 2 and 3 the 97.5th percentiles are over three times the non-pregnant URL provided by the manufacturer. Trimester- and assay-specific reference intervals for copeptin and MR-proADM should be used. In addition, consecutive measurements and the time frame between measurements should be considered as the differences seen with or in advance of preeclampsia can be expected to be relatively small compared to the reference intervals.
Modern analytical chemistry in the contemporary world
NASA Astrophysics Data System (ADS)
Šíma, Jan
2016-12-01
Students not familiar with chemistry tend to misinterpret analytical chemistry as some kind of the sorcery where analytical chemists working as modern wizards handle magical black boxes able to provide fascinating results. However, this approach is evidently improper and misleading. Therefore, the position of modern analytical chemistry among sciences and in the contemporary world is discussed. Its interdisciplinary character and the necessity of the collaboration between analytical chemists and other experts in order to effectively solve the actual problems of the human society and the environment are emphasized. The importance of the analytical method validation in order to obtain the accurate and precise results is highlighted. The invalid results are not only useless; they can often be even fatal (e.g., in clinical laboratories). The curriculum of analytical chemistry at schools and universities is discussed. It is referred to be much broader than traditional equilibrium chemistry coupled with a simple description of individual analytical methods. Actually, the schooling of analytical chemistry should closely connect theory and practice.
Yang, Jeong-Jin; Jeong, Dong-Hyuk; Lim, Yoon-Kyu
2018-04-19
Physiological characteristics, such as blood chemistry values, are valuable for evaluating the health of the animals. To our knowledge, these values have never been reported for the free-ranging Asiatic black bear ( Ursus thibetanus; ABB). Thus, 28 blood chemistry values from 50 free-ranging ABBs captured in Jirisan National Park, Republic of Korea, from 2005 to 2016 were evaluated. The aim of this study was to establish blood chemistry reference values for the free-ranging ABBs during both the hibernating and nonhibernating seasons. During hibernation, mean values of creatinine (CRE), total cholesterol, total protein (TP), albumin (ALB), triglycerides, and Mg were significantly higher than those during nonhibernation; however, mean values of blood urea nitrogen, urea nitrogen to creatinine (U/C) ratio, inorganic phosphorous (IP), aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transferase, lactate dehydrogenase (LDH), high-density lipoprotein cholesterol, and alkaline phosphatase (ALP) were significantly lower. Age differences (young vs. adult) were found in IP, LDH, TP, and ALB values during hibernation and in the U/C ratio, Ca, IP, ALP, creatine kinase myocardial band, CRE, total bilirubin, and uric acid values during nonhibernation. However, there were no sex differences (male vs. female).
Click Chemistry, a Powerful Tool for Pharmaceutical Sciences
Hein, Christopher D.; Liu, Xin-Ming; Wang, Dong
2008-01-01
Click chemistry refers to a group of reactions that are fast, simple to use, easy to purify, versatile, regiospecific, and give high product yields. While there are a number of reactions that fulfill the criteria, the Huisgen 1,3-dipolar cycloaddition of azides and terminal alkynes has emerged as the frontrunner. It has found applications in a wide variety of research areas, including materials sciences, polymer chemistry, and pharmaceutical sciences. In this manuscript, important aspects of the Huisgen cycloaddition will be reviewed, along with some of its many pharmaceutical applications. Bioconjugation, nanoparticle surface modification, and pharmaceutical-related polymer chemistry will all be covered. Limitations of the reaction will also be discussed. PMID:18509602
NASA Astrophysics Data System (ADS)
Krepper, Gabriela; Romeo, Florencia; Fernandes, David Douglas de Sousa; Diniz, Paulo Henrique Gonçalves Dias; de Araújo, Mário César Ugulino; Di Nezio, María Susana; Pistonesi, Marcelo Fabián; Centurión, María Eugenia
2018-01-01
Determining fat content in hamburgers is very important to minimize or control the negative effects of fat on human health, effects such as cardiovascular diseases and obesity, which are caused by the high consumption of saturated fatty acids and cholesterol. This study proposed an alternative analytical method based on Near Infrared Spectroscopy (NIR) and Successive Projections Algorithm for interval selection in Partial Least Squares regression (iSPA-PLS) for fat content determination in commercial chicken hamburgers. For this, 70 hamburger samples with a fat content ranging from 14.27 to 32.12 mg kg- 1 were prepared based on the upper limit recommended by the Argentinean Food Codex, which is 20% (w w- 1). NIR spectra were then recorded and then preprocessed by applying different approaches: base line correction, SNV, MSC, and Savitzky-Golay smoothing. For comparison, full-spectrum PLS and the Interval PLS are also used. The best performance for the prediction set was obtained for the first derivative Savitzky-Golay smoothing with a second-order polynomial and window size of 19 points, achieving a coefficient of correlation of 0.94, RMSEP of 1.59 mg kg- 1, REP of 7.69% and RPD of 3.02. The proposed methodology represents an excellent alternative to the conventional Soxhlet extraction method, since waste generation is avoided, yet without the use of either chemical reagents or solvents, which follows the primary principles of Green Chemistry. The new method was successfully applied to chicken hamburger analysis, and the results agreed with those with reference values at a 95% confidence level, making it very attractive for routine analysis.
Krepper, Gabriela; Romeo, Florencia; Fernandes, David Douglas de Sousa; Diniz, Paulo Henrique Gonçalves Dias; de Araújo, Mário César Ugulino; Di Nezio, María Susana; Pistonesi, Marcelo Fabián; Centurión, María Eugenia
2018-01-15
Determining fat content in hamburgers is very important to minimize or control the negative effects of fat on human health, effects such as cardiovascular diseases and obesity, which are caused by the high consumption of saturated fatty acids and cholesterol. This study proposed an alternative analytical method based on Near Infrared Spectroscopy (NIR) and Successive Projections Algorithm for interval selection in Partial Least Squares regression (iSPA-PLS) for fat content determination in commercial chicken hamburgers. For this, 70 hamburger samples with a fat content ranging from 14.27 to 32.12mgkg -1 were prepared based on the upper limit recommended by the Argentinean Food Codex, which is 20% (ww -1 ). NIR spectra were then recorded and then preprocessed by applying different approaches: base line correction, SNV, MSC, and Savitzky-Golay smoothing. For comparison, full-spectrum PLS and the Interval PLS are also used. The best performance for the prediction set was obtained for the first derivative Savitzky-Golay smoothing with a second-order polynomial and window size of 19 points, achieving a coefficient of correlation of 0.94, RMSEP of 1.59mgkg -1 , REP of 7.69% and RPD of 3.02. The proposed methodology represents an excellent alternative to the conventional Soxhlet extraction method, since waste generation is avoided, yet without the use of either chemical reagents or solvents, which follows the primary principles of Green Chemistry. The new method was successfully applied to chicken hamburger analysis, and the results agreed with those with reference values at a 95% confidence level, making it very attractive for routine analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Fuentes-Arderiu, Xavier; Alonso-Gregorio, Eduardo; Alvarez-Funes, Virtudes; Ambrós-Marigómez, Carmen; Coca-Fábregas, Lluís; Cruz-Placer, Marta; Díaz-Fernández, Julián; Pinel-Julián, María Pilar; Gutiérrez-Cecchini, Beatriz; Herrero-Bernal, Pilar; Sempere-Alcocer, Marcos; García-Caballero, Francisca; Del Mar Larrea-Ortiz-Quintana, María; La-Torre-Marcellán, Pedro; Del Señor López-Vélez, María; Mar-Medina, Carmen; Martín-Oncina, Javier; Rodríguez-Hernández, María Victoria; Romero-Sotomayor, María Victoria; Serrano-López, Cándido; Sicilia-Enríquez-de-Salamanca, Adolfo; Velasco-Romero, Ana María; Juvé-Cuxart, Santiago
2007-01-01
Clinical laboratories seeking accreditation for compliance with ISO 15189:2003 need to demonstrate that the physiological reference intervals communicated to all users of the laboratory service are appropriate for the patient population served and for the measurement systems used. In the case of immunological quantities, few articles have been published in peer-reviewed journals. A total of 21 clinical laboratories in different regions of Spain collaborated in identifying reference individuals and determining adult reference intervals for some immunological quantities measured using RD/Hitachi Modular Analytics analysers and Tina-Quant reagent systems. These immunological quantities are the mass concentrations of immunoglobulin A, immunoglobulin G, immunoglobulin M, complement C3c and complement C4 in serum. All the logistic work was carried out in co-operation with the supplier of the reagents and analysers (Roche Diagnostics España, S.L., Sant Cugat del Vallès, Catalonia, Spain). From the set of reference values obtained by each laboratory, multicentre reference limits were estimated non-parametrically. The reference intervals estimated in this study for concentrations of serum components under consideration are: complement C3c, 0.62-1.64 g/L for women and men; complement C4, 0.14-0.72 g/L for women and men; immunoglobulin A, 0.89-4.80 g/L for women and men; immunoglobulin G, 6.5-14.3 g/L for women and men; and immunoglobulin M, 0.48-3.38 g/L for women and 0.41-2.46 g/L for men.
Reference values for exposure of wildlife to contaminants are needed to cost effectively determine if a site is contaminated and to rank sites that are above background levels. Epidemiological techniques originally developed for clinical chemistry and for determining exposures t...
Reference hematologic and plasma chemistry values of brown tree snakes (Boiga irregularis).
Lamirande, E W; Bratthauer, A D; Fischer, D C; Nichols, D K
1999-12-01
Reference hematologic and plasma chemistry values were determined from 103 blood samples collected from 53 clinically healthy brown tree snakes (Boiga irregularis). Female snakes had significantly higher mean plasma values for total solids, total protein, calcium (Ca), phosphorus (P), uric acid, and blood monocyte percentage than did males, whereas males had significantly higher mean plasma fibrinogen values. The variances for hematocrit, monocyte percentage, azurophil percentage, plasma total solids, plasma total protein, albumin, Ca, and P also differed significantly between sexes. The higher mean values and greater variances for plasma total protein, plasma total solids, Ca, and P in the female snakes were probably associated with yolk synthesis and accumulation.
Acute phase proteins in healthy goats: establishment of reference intervals.
Heller, Meera C; Johns, Jennifer L
2015-03-01
Acute inflammatory processes can trigger increased production of acute phase proteins (APPs) that can be useful biomarkers of inflammation. APPs are diverse and include proteins involved in coagulation, opsonization, iron regulation, and limitation of tissue injury. Haptoglobin, serum amyloid A, and alpha-1 acid glycoprotein have been proposed as useful APPs in goats. APPs can differ markedly by species, therefore species-specific reference intervals and studies are necessary. The objective of this study was to determine species-specific reference intervals for 4 APPs in goats. Haptoglobin, serum amyloid A, lipopolysaccharide binding protein, and alpha-1 acid glycoprotein were measured in in 54 clinically normal adult goats. APPs were measured using goat-specific commercial enzyme-linked immunosorbent assay kits. Results were analyzed by 1-way analysis of variance to compare sexes and breeding status. Reference Value Advisor was used to calculate reference limits according to the IFCC-CLSI guidelines. Only 1 APP was found to vary in healthy animals; serum haptoglobin was increased in lactating animals and decreased in pregnant does in their second trimester when compared with open, nonlactating does. No sex-based differences were seen for any of the APPs measured. We report normal reference intervals for 4 serum APPs that may be useful as disease markers. Haptoglobin should be interpreted with caution in animals with unknown pregnancy status. Further studies are needed to determine whether these APPs are useful biomarkers in goat disease states. © 2015 The Author(s).
Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen
2015-09-01
The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.
Thomas, Kathryn E; Hall, Roland I; Scrimgeour, Garry J
2015-09-01
Defining reference conditions is central to identifying environmental effects of anthropogenic activities. Using a watershed approach, we quantified reference conditions for benthic algal communities and their relations to physico-chemical conditions in rivers in the South Nahanni River watershed, NWT, Canada, in 2008 and 2009. We also compared the ability of three descriptors that vary in terms of analytical costs to define algal community structure based on relative abundances of (i) all algal taxa, (ii) only diatom taxa, and (iii) photosynthetic pigments. Ordination analyses showed that variance in algal community structure was strongly related to gradients in environmental variables describing water physico-chemistry, stream habitats, and sub-watershed structure. Water physico-chemistry and local watershed-scale descriptors differed significantly between algal communities from sites in the Selwyn Mountain ecoregion compared to sites in the Nahanni-Hyland ecoregions. Distinct differences in algal community types between ecoregions were apparent irrespective of whether algal community structure was defined using all algal taxa, diatom taxa, or photosynthetic pigments. Two algal community types were highly predictable using environmental variables, a core consideration in the development of Reference Condition Approach (RCA) models. These results suggest that assessments of environmental impacts could be completed using RCA models for each ecoregion. We suggest that use of algal pigments, a high through-put analysis, is a promising alternative compared to more labor-intensive and costly taxonomic approaches for defining algal community structure.
Roberts, William A; Guitar, Nicole A; Marsh, Heidi L; MacDonald, Hayden
2016-05-01
The interaction of working and reference memory was studied in rats on an eight-arm radial maze. In two experiments, rats were trained to perform working memory and reference memory tasks. On working memory trials, they were allowed to enter four randomly chosen arms for reward in a study phase and then had to choose the unentered arms for reward in a test phase. On reference memory trials, they had to learn to visit the same four arms on the maze on every trial for reward. Retention was tested on working memory trials in which the interval between the study and test phase was 15 s, 15 min, or 30 min. At each retention interval, tests were performed in which the correct WM arms were either congruent or incongruent with the correct RM arms. Both experiments showed that congruency interacted with retention interval, yielding more forgetting at 30 min on incongruent trials than on congruent trials. The effect of reference memory strength on the congruency effect was examined in Experiment 1, and the effect of associating different contexts with working and reference memory on the congruency effect was studied in Experiment 2.
Canine and feline hematology reference values for the ADVIA 120 hematology system.
Moritz, Andreas; Fickenscher, Yvonne; Meyer, Karin; Failing, Klaus; Weiss, Douglas J
2004-01-01
The ADVIA 120 is a laser-based hematology analyzer with software applications for animal species. Accurate reference values would be useful for the assessment of new hematologic parameters and for interlaboratory comparisons. The goal of this study was to establish reference intervals for CBC results and new parameters for RBC morphology, reticulocytes, and platelets in healthy dogs and cats using the ADVIA 120 hematology system. The ADVIA 120, with multispecies software (version 1.107-MS), was used to analyze whole blood samples from clinically healthy dogs (n=46) and cats (n=61). Data distribution was determined and reference intervals were calculated as 2.5 to 97.5 percentiles and 25 to 75 percentiles. Most data showed Gaussian or log-normal distribution. The numbers of RBCs falling outside the normocytic-normochromic range were slightly higher in cats than in dogs. Both dogs and cats had reticulocytes with low, medium, and high absorbance. Mean numbers of large platelets and platelet clumps were higher in cats compared with dogs. Reference intervals obtained on the ADVIA 120 provide valuable baseline information for assessing new hematologic parameters and for interlaboratory comparisons. Differences compared with previously published reference values can be attributed largely to differences in methodology.
Haschke-Becher, Elisabeth; Kainz, Alexander; Bachmann, Claude
2016-01-01
To compare plasma levels of amino acids and clinical chemistry parameters in healthy infants at 1 and 4 months of age and to establish corresponding reference limits. Data of three multicenter studies assessing the safety of new infant formulas were used. During these studies infants of both age-groups were either breast-fed or received formulas of low or high protein content. All samples were analyzed centrally in the same accredited laboratory. Plasma was collected from 521 infants in total, 157 boys and 135 girls aged 1 month and 121 boys and 108 girls aged 4 months. At the age of 1 month, 62 infants had received exclusively breast milk, 198 exclusively formula, and 27 both; in the 4-months age group corresponding numbers were 49, 158 and 18, respectively; for 9 infants, diet was unknown. Concentrations of most amino acids and clinical chemistry parameters differed significantly between both ages. Regardless of age, most plasma amino acid levels were comparable or lower in breast-fed than in formula-fed infants whereas at 1 month of age most clinical chemistry parameters were higher. While in breast-fed infants the plasma urea concentration decreased over 4 months of age, it increased in formula-fed infants. There were significant differences between infants fed a low and high protein formula. At both ages, high protein formulas resulted in significantly higher threonine, 2-aminobutyrate, and urea concentrations. For clinical use, age- and diet specific reference limits in infants are warranted.
ERIC Educational Resources Information Center
Nbina, Jacobson Barineka; Obomanu, B. Joseph
2011-01-01
We report a study focused on how problem-solving instructional strategies would affect students' achievement and retention in Chemistry with particular reference to River State. A pre-test, post-test, non-equivalent control group design was adopted. Two research questions and two hypotheses were respectively answered and tested. Purposive and…
Green chemistry: development trajectory
NASA Astrophysics Data System (ADS)
Moiseev, I. I.
2013-07-01
Examples of applications of green chemistry methods in heavy organic synthesis are analyzed. Compounds, which can be produced by the processing of the biomass, and the criteria for the selection of the most promising products are summarized. The current status of the ethanol production and processing is considered. The possibilities of the use of high fatty acid triglycerides, glycerol, succinic acid, and isoprene are briefly discussed. The bibliography includes 67 references.
ERIC Educational Resources Information Center
Niaz, Mansoor
The main objective of this study is to construct models based on strategies students use to solve chemistry problems and to show that these models form sequences of progressive transitions similar to what Lakatos (1970) in the history of science refers to as progressive 'problemshifts' that increase the explanatory' heuristic power of the models.…
ERIC Educational Resources Information Center
Niaz, Mansoor
2000-01-01
Describes a study that was designed to develop a framework for examining the way in which chemistry textbooks describe the kinetic theory and related issues. The framework was developed by a rational reconstruction of the kinetic molecular theory of gases based on historians and philosophers of science. (Contains 102 references.)(Author/LRW)
USSR and Eastern Europe Scientific Abstracts, Chemistry. Number 49
1976-11-04
phosphorus tribromide with oxygen initia- tion leads to the synthesis of l-bromoalkane-2-phosphonous acid dibromides. References 8: 4 Russian, 4 Western. 1 ...are developed for synthesis of dialkylmethylphosphonates by nitration of ethoxyvinylphosphonates. References 21: 19 Russian, 2 Western. 1 / 1 USSR...spectroscopic data and reverse synthesis . Figures 2; References 3: 1 Russian, 2 Western. 1 / 1 28 USSR UDC 547.26 GOLOLOBOV, YU. G., BOLDESKUL, I
Student Restraints to Reform: Conceptual Change Issues in Enhancing Students' Learning Processes.
ERIC Educational Resources Information Center
Thomas, Gregory P.
1999-01-01
Describes a teacher-researcher's investigation into barriers to student adoption of an alternative referent for learning and its consequential learning strategies in an 11th-grade chemistry class. Suggests that various contextual factors influenced students' willingness to adopt the alternative referent, and that students' beliefs, trust of the…
Yan, Cunling; Hu, Jian; Yang, Jia; Chen, Zhaoyun; Li, Huijun; Wei, Lianhua; Zhang, Wei; Xing, Hao; Sang, Guoyao; Wang, Xiaoqin; Han, Ruilin; Liu, Ping; Li, Zhihui; Li, Zhiyan; Huang, Ying; Jiang, Li; Li, Shunjun; Dai, Shuyang; Wang, Nianyue; Yang, Yongfeng; Ma, Li; Soh, Andrew; Beshiri, Agim; Shen, Feng; Yang, Tian; Fan, Zhuping; Zheng, Yijie; Chen, Wei
2018-04-01
Protein induced by vitamin K absence or antagonist-II (PIVKA-II) has been widely used as a biomarker for liver cancer diagnosis in Japan for decades. However, the reference intervals for serum ARCHITECT PIVKA-II have not been established in the Chinese population. Thus, this study aimed to measure serum PIVKA-II levels in healthy Chinese subjects. This is a sub-analysis from the prospective, cross-sectional and multicenter study (ClinicalTrials.gov Identifier: NCT03047603). A total of 892 healthy participants (777 Han and 115 Uygur) with complete health checkup results were recruited from 7 regional centers in China. Serum PIVKA-II level was measured by ARCHITECT immunoassay. All 95% reference ranges were estimated by nonparametric method. The distribution of PIVKA-II values showed significant difference with ethnicity and sex, but not age. The 95% reference range of PIVKA-II was 13.62-40.38 mAU/ml in Han Chinese subjects and 15.16-53.74 mAU/ml in Uygur subjects. PIVKA-II level was significantly higher in males than in females (P < 0.001). The 95% reference range of PIVKA-II was 15.39-42.01 mAU/ml in Han males while 11.96-39.13 mAU/ml in Han females. The reference interval of serum PIVKA-II on the Architect platform was established in healthy Chinese adults. This will be valuable for future clinical and laboratory studies performed using the Architect analyzer. Different ethnic backgrounds and analytical methods underline the need for redefining the reference interval of analytes such as PIVKA-II, in central laboratories in different countries. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Yu, Lian; Yue, Huakui; Lin, Haoyun; Wu, Wenyuan
2014-11-04
To explore the thyroid function distribution of different trimesters among normal pregnant women and establish the reference interval for maternal thyroid function during pregnancy in Shenzhen, China. A prospective study was conducted for healthy pregnant women in first trimester (n = 334), second trimester (n = 272), third trimester (n = 271) and non-pregnant controls (n = 77) from December 2012 to June 2013 at our hospital. Free triiodothyronine (FT3), free thyroxine (FT4), thyroid stimulating hormone (TSH), triiodothyronine (TT3) and thyroxine (T4) of four groups were measured and analyzed. And the reference intervals for different trimesters were established. TSH declined in the first trimester and then rose in the second trimester. The reference ranges of TSH for early, middle and late pregnancy were 0.08-4.39, 0.41-4.16 and 0.30-5.46 mIU/L respectively. FT4 and healthy control groups showed no significant difference in the first trimester. But it declined in the second trimester. The reference ranges of FT4 for early, middle and late pregnancy were 7.74-14.58, 6.81-12.00 and 6.36-10.99 pmol/L respectively. FT3 rose slightly in the first trimester and then gradually decreased. The reference ranges of FT3 for early, middle and late pregnancy were 3.59-5.59, 3.34-4.91 and 3.09-4.58 pmol/L respectively. As compared with healthy control women in Shenzhen, thyroid function indicators of pregnant women show statistically significant differences. And the establishment of indicators of women's thyroid function reference intervals for different trimesters has important clinical significance in Shenzhen.
Applications of the Cambridge Structural Database in organic chemistry and crystal chemistry.
Allen, Frank H; Motherwell, W D Samuel
2002-06-01
The Cambridge Structural Database (CSD) and its associated software systems have formed the basis for more than 800 research applications in structural chemistry, crystallography and the life sciences. Relevant references, dating from the mid-1970s, and brief synopses of these papers are collected in a database, DBUse, which is freely available via the CCDC website. This database has been used to review research applications of the CSD in organic chemistry, including supramolecular applications, and in organic crystal chemistry. The review concentrates on applications that have been published since 1990 and covers a wide range of topics, including structure correlation, conformational analysis, hydrogen bonding and other intermolecular interactions, studies of crystal packing, extended structural motifs, crystal engineering and polymorphism, and crystal structure prediction. Applications of CSD information in studies of crystal structure precision, the determination of crystal structures from powder diffraction data, together with applications in chemical informatics, are also discussed.
He, Meilin; Zhang, Jie
2011-06-01
In China, the traceability of clinical chemistry methods is still immature. Therefore, it is necessary to establish a reference measurement procedure and evaluate commercial reagent kits using such established procedures. We reproduced the reference measurement procedure for serum total protein, as recommended by the American Association for Clinical Chemistry (AACC). We evaluated the performance by Clinical Laboratory Standard Institute (CLSI) guidelines EP15-A and EP6-A. Subsequently, four commercial reagent kits were evaluated by the reproduced reference procedure following CLSI guideline EP9-A2. The performance of the reproduced reference procedure was as follows: CVs ranged from 0.47% to 0.85% at medical decision levels (X(c)) of 45 g/L, 60 g/L and 80 g/L. Linearity was Y=1.0022X-0.2121 (r=0.9999), and recovery ranged from 100.2% to 102.4%. The External Quality Assessment Scheme for Reference Laboratories in Laboratory Medicine (RELA) was applied, and the result was within the limit of equivalence. The linear relationships of four commercial reagent kits, Merit Choice, KHB, Leadman, and Olympus, were, respectively: Y=0.9922X+0.5776 (r=0.9961); Y=0.9936X+0.4316 (r=0.9992); Y=0.9949X+0.9129 (r=0.9987) and Y=0.9923X+0.8876 (r=0.9989). KHB showed slight negative bias, and the mean±SD was -0.03±0.60 g/L. Merit Choice, Leadman, and Olympus all showed positive bias, and the mean±SDs were 0.02±0.63 g/L, 0.55±0.77 g/L and 0.34±0.71 g/L, respectively. The correlation and bias of four commercial reagent kits for serum total protein were found to be acceptable. Thus, these reagent kits can be used reliably in China.
Trimester specific reference intervals for thyroid function tests in normal Indian pregnant women.
Sekhri, Tarun; Juhi, Juhi Agarwal; Wilfred, Reena; Kanwar, Ratnesh S; Sethi, Jyoti; Bhadra, Kuntal; Nair, Sirimavo; Singh, Satveer
2016-01-01
Accurate assessment of thyroid function during pregnancy is critical, for initiation of thyroid hormone therapy, as well as for adjustment of thyroid hormone dose in hypothyroid cases. We evaluated pregnant women who had no past history of thyroid disorders and studied their thyroid function in each trimester. 86 normal pregnant women in the first trimester of pregnancy were selected for setting reference intervals. All were healthy, euthyroid and negative for thyroid peroxidase antibody (TPOAb). These women were serially followed throughout pregnancy. 124 normal nonpregnant subjects were selected for comparison. Thyrotropin (TSH), free thyroxine (FT4), free triiodothyronine (FT3) and anti-TPO were measured using Roche Elecsys 1010 analyzer. Urinary iodine content was determined by simple microplate method. The 2.5th and 97.5th percentiles were calculated as the reference intervals for thyroid hormone levels during each trimester. SPSS (version 14.0, SPSS Inc., Chicago, IL, USA) was used for data processing and analysis. The reference intervals for the first, second and third trimesters for the following parameters: TSH 0.09-6.65, 0.51-6.66, 0.91-4.86 µIU/mL, FT4 9.81-18.53, 8.52-19.43, 7.39-18.28 pM/L and FT3 3.1-6.35, 2.39-5.12, 2.57-5.68 pM/L respectively. Thyroid hormone concentrations significantly differed during pregnancy at different stages of gestation. The pregnant women in the study had median urinary iodine concentration of 150-200 µg/l during each trimester. The trimester-specific reference intervals for thyroid tests during pregnancy have been established for pregnant Indian women serially followed during pregnancy using 2.5th and 97.5th percentiles.
Kim, Borahm; Lee, Mi Na; Park, Hyung Doo; Kim, Jong Won; Chang, Yun Sil; Park, Won Soon; Lee, Soo Youn
2015-11-01
Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because of limited data on its use in the Korean population, LC-MS/MS has not yet been incorporated into newborn screening programs in this region. The present study aims to develop and validate an LC-MS/MS method for the simultaneous determination of seven steroids in dried blood spots (DBS) for CAH screening, and to define age-specific reference intervals in the Korean population. We developed and validated an LC-MS/MS method to determine the reference intervals of cortisol, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, and 11-deoxycorticosterone simultaneously in 453 DBS samples. The samples were from Korean subjects stratified by age group (78 full-term neonates, 76 premature neonates, 89 children, and 100 adults). The accuracy, precision, matrix effects, and extraction recovery were satisfactory for all the steroids at three concentrations; values of intra- and inter-day precision coefficients of variance, bias, and recovery were 0.7-7.7%, -1.5-9.8%, and 49.3-97.5%, respectively. The linearity range was 1-100 ng/mL for cortisol and 0.5-50 ng/mL for other steroids (R²>0.99). The reference intervals were in agreement with the previous reports. This LC-MS/MS method and the reference intervals validated in the Korean population can be successfully applied to analyze seven steroids in DBS for the diagnosis of CAH.
Deitz, Krysta L; Makielski, Kelly M; Williams, Jackie M; Lin, Hui; Morrison, Jo Ann
2015-09-01
Ursodeoxycholic acid (UDCA) is commonly used for the treatment of hepatobiliary disease. UDCA is a bile acid that can be detected in the bile acid assay. Its effect on biochemical analytes is unknown. The aim of this study was to determine the effect of 6-8 weeks of UDCA administration on fasting and postprandial concentrations of serum bile acids (SBA), cholesterol, triglycerides, bilirubin, and liver enzyme activities in healthy dogs. Twenty healthy dogs received UDCA for 6-8 weeks. CBC, biochemistry profile, urinalysis, fasting and postprandial SBA, and hepatobiliary ultrasound examination were performed prior to starting UDCA (timepoint 0) and after 6-8 weeks of therapy, while animals were still receiving UDCA (timepoint 1). Timepoint 0 and timepoint 1 values were compared with a paired t-test. SBA were remeasured 72 hours after UDCA discontinuation. Only mean fasting SBA at timepoint 1 increased significantly (P = .03) from timepoint 0 (2.26 μmol/L at time 0 and 3.81 μmol/L at time 1) but were not elevated above the normal reference interval (0-9 μmol/L). Two dogs had timepoint 1 fasting SBA above the reference interval (10 and 11.7 μmol/L). One dog had timepoint 1 postprandial SBA above the reference interval at 20.1 μmol/L (reference interval 0-17 μmol/L). Repeat SBA 72 hours after UDCA discontinuation were normal. Long-term administration of UDCA to healthy dogs may increase fasting SBA above pretreatment values (typically within the reference interval). Long-term administration of UDCA to healthy dogs does not alter liver enzyme activities, and bilirubin, cholesterol, or triglyceride concentrations. © 2015 American Society for Veterinary Clinical Pathology.
Parker, H L; Tucker, E; Blackshaw, E; Hoad, C L; Marciani, L; Perkins, A; Menne, D; Fox, M
2017-11-01
Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study presents the reference intervals of the modular "Nottingham test meal" (NTM) for assessment of gastric function by gamma scintigraphy (GSc) in a representative population of healthy volunteers (HVs) stratified for age and sex. The NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and an optional solid component (12 solid agar-beads (0 kcal). Filling and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gamma scintigraphy parameters that describe early and late phase Gastric emptying (GE) were calculated from validated models. Gastric emptying (GE) of the liquid component was measured in 73 HVs (male 34; aged 45±20). The NTM produced normal postprandial fullness (VAS ≥30 in 41/74 subjects). Dyspeptic symptoms were rare (VAS ≥30 in 2/74 subjects). Gastric emptying half-time with the Liquid- and Solid-component -NTM was median 44 (95% reference interval 28-78) minutes and 162 (144-193) minutes, respectively. Gastric accommodation was assessed by the ratio of the liquid-NTM retained in the proximal:total stomach and by Early phase emptying assessed by gastric volume after completing the meal (GCV0). No consistent effect of anthropometric measures on GE parameters was present. Reference intervals are presented for GSc measurements of gastric motor and sensory function assessed by the NTM. Studies involving patients are required to determine whether the reference interval range offers optimal diagnostic sensitivity and specificity. © 2017 The Authors. Neurogastroenterology & Motility Published by John Wiley & Sons Ltd.
Spatial interpolation of daily reference evapotranspiration in the Texas High Plains
USDA-ARS?s Scientific Manuscript database
The Texas High Plains Evapotranspiration (ET) Network collects meteorological data from 18 grass reference weather stations at hourly intervals and estimates hourly and daily reference ET using the American Society of Civil Engineers (ASCE) Standardized Reference ET equation. Producers in the Texas ...
Matsche, Mark A; Gibbons, Jarrett
2012-12-01
Shortnose sturgeon (Acipenser brevirostrum) spawning migrations on the Cooper River are impeded by Pinopolis Dam, Lake Moultrie, South Carolina. Sturgeon and other species aggregate below the dam in late winter/early spring and are subjected to a variety of stressors stemming from crowding, poor habitat quality, and injuries that appear to be caused by boat propeller or turbine strikes. Spawning has been documented in the tailrace, but reproductive success has not been verified as no juveniles have been captured. Fish within the dam tailrace were captured by gill net during winter, 2005 and 2007-2011, and physiological condition was assessed using a panel of hematologic and biochemical indices. Plasma phosphorus and calcium were significantly higher in females, while PCV and aspartate aminotransferase were significantly higher in males, indicating sex-specific physiological changes triggered during maturity. A marked leucopenia, accompanied by lymphopenia and neutrophilia, was evident in both sexes and was consistent across years, indicating that these fish were under chronic stress. Testosterone and estradiol levels and hematologic and biochemical reference intervals are provided for comparative purposes.
Fenton, Tanis R; Lyon, Andrew W; Rose, M Sarah
2011-08-31
The objective was to determine the influence of gestational age, maternal, and neonatal variables on reference intervals for cord blood bone minerals (calcium, phosphate, magnesium) and related laboratory tests (alkaline phosphatase, and albumin-adjusted calcium), and to develop gestational age specific reference intervals based on infants without influential pathological conditions. Cross-sectional study. 702 babies were identified as candidates for this study in a regional referral neonatal unit. After exclusions (for anomalies, asphyxia, maternal magnesium sulfate administration, and death), relationships were examined between cord blood serum laboratory analytes (calcium, phosphate, magnesium, alkaline phosphatase, and albumin-adjusted calcium) with gestation age and also with maternal and neonatal variables using multiple linear regression. Infants with influential pathological conditions were omitted from the development of gestational age specific reference intervals for the following categories: 23-27, 28-31, 32-34, 35-36 and > 36 weeks. Among the 506 preterm and 54 terms infants included in the sample. Phosphate, magnesium, and alkaline phosphatase in cord blood serum decreased with gestational age, calcium increased with gestational age. Those who were triplets, small for gestational age, and those whose mother had pregnancy-induced hypertension were influential for most of the analytes. The reference ranges for the preterm infants ≥ 36 weeks were: phosphate 1.5 to 2.6 mmol/L (4.5 to 8.0 mg/dL), calcium: 2.1 to 3.1 mmol/L (8.3 to 12.4 mg/dL); albumin-adjusted calcium: 2.3 to 3.2 mmol/L (9.1 to 12.9 mg/dL); magnesium 0.6 to 1.0 mmol/L (1.4 to 2.3 mg/dL), and alkaline phosphatase 60 to 301 units/L. These data suggest that gestational age, as well as potentially pathogenic maternal and neonatal variables should be considered in the development of reference intervals for preterm infants.
Simplified estimation of age-specific reference intervals for skewed data.
Wright, E M; Royston, P
1997-12-30
Age-specific reference intervals are commonly used in medical screening and clinical practice, where interest lies in the detection of extreme values. Many different statistical approaches have been published on this topic. The advantages of a parametric method are that they necessarily produce smooth centile curves, the entire density is estimated and an explicit formula is available for the centiles. The method proposed here is a simplified version of a recent approach proposed by Royston and Wright. Basic transformations of the data and multiple regression techniques are combined to model the mean, standard deviation and skewness. Using these simple tools, which are implemented in almost all statistical computer packages, age-specific reference intervals may be obtained. The scope of the method is illustrated by fitting models to several real data sets and assessing each model using goodness-of-fit techniques.
Badrick, Tony; Hickman, Peter E
2008-08-01
* For consistency of reporting the same number of significant figures should be used for results and reference intervals. * The choice of the reporting interval should be based on analytical imprecision (measurement uncertainty).
NASA Technical Reports Server (NTRS)
Keating, G. M. (Editor)
1989-01-01
A set of preliminary reference atmosphere models of significant trace species which play important roles in controlling the chemistry, radiation budget, and circulation patterns of the atmosphere were produced. These models of trace species distributions are considered to be reference models rather than standard models; thus, it was not crucial that they be correct in an absolute sense. These reference models can serve as a means of comparison between individual observations, as a first guess in inversion algorithms, and as an approximate representation of observations for comparison to theoretical calculations.
Alcohol References on Undergraduate Males’ Facebook Profiles
Egan, Katie G.; Moreno, Megan A.
2011-01-01
Perceived peer alcohol use is a predictor of consumption in college males; frequent references to alcohol on Facebook may encourage alcohol consumption. Content analysis of college males’ Facebook profiles identified references to alcohol. The average age of 225 identified profiles was 19.9 years. Alcohol references were present on 85.3% of the profiles; the prevalence of alcohol was similar across each undergraduate grade. The average number of alcohol references per profile was 8.5 but increased with undergraduate year (p = .003; confidence interval = 1.5, 7.5). Students who were of legal drinking age referenced alcohol 4.5 times more than underage students, and an increase in number of Facebook friends was associated with an increase in displayed alcohol references (p < .001; confidence interval = 0.009, 0.02). Facebook is widely used in the college population; widespread alcohol displays on Facebook may influence social norms and cause increases in male college students’ alcohol use. PMID:21406490
ERIC Educational Resources Information Center
Lafferty, Meghan
2009-01-01
This article examines what is desirable in online reference books in science and technology and outlines a framework for evaluating their interfaces. The framework considers factors unique to these subject areas like chemical structures and numerical data. Criteria in three categories, navigability, searchability, and results, were applied to five…
Lack of harmonization in sweat testing for cystic fibrosis - a national survey.
Christiansen, Anne Lindegaard; Nybo, Mads
2014-11-01
Sweat testing is used in the diagnosis of cystic fibrosis. Interpretation of the sweat test depends, however, on the method performed since conductivity, osmolality and chloride concentration all can be measured as part of a sweat test. The aim of this study was to investigate how performance of the test is organized in Denmark. Departments conducting the sweat test were contacted and interviewed following a premade questionnaire. They were asked about methods performed, applied NPU (Nomenclature for Properties and Units) code, reference interval, recommended interpretation and referred literature. 14 departments performed the sweat test. One department measured chloride and sodium concentration, while 13 departments measured conductivity. One department used a non-existing NPU code, two departments applied NPU codes inconsistent with the method performed, four departments applied no NPU code and seven applied a correct NPU code. Ten of the departments measuring conductivity applied reference intervals. Nine departments measuring conductivity had recommendations of a normal area, a grey zone and a pathological value, while four departments only applied a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic fibrosis. Because diagnosing cystic fibrosis is a combined effort between local pediatric departments, biochemical and genetic departments and cystic fibrosis centers, a national harmonization is necessary to assure correct clinical use.
Scope, Alexandra; Schwendenwein, Ilse; Stanclova, Gabriela; Vobornik, Angela; Zink, Richard
2016-06-01
The Ural owl (Strix uralensis) is the biggest forest-living owl in Austria; however, it became extinct in Austria through poaching and habitat loss more than half a century ago. The birds examined in the present study were breeding pairs from the reintroduction project with the aim of determining exploratory plasma biochemistry reference intervals in Ural owls and evaluating the amount of biological variation between seasons, sexes, and ages. A total of 45 birds were sampled, including 13 adult males, 14 adult females, and 18 juvenile birds. Remarkably, almost all of the analytes showed significant differences between the subgroups, primarily between seasons, followed by age and sex. Only creatinkinase, glucose, lactatdehydrogenase, and triglycerides did not show any significant variations. Despite partitioning of reference values into subgroups according to biological variation diminishing the number of reference individuals in the respective groups, the resulting smaller reference intervals will improve medical assessment. The results of the present study once again demonstrate that significant seasonal fluctuations must be expected and considered in the interpretation. It can be assumed that these differences are probably even greater in free-range birds with considerable changes in food quantity and quality during and between years.
Fragment-to-Lead Medicinal Chemistry Publications in 2015.
Johnson, Christopher N; Erlanson, Daniel A; Murray, Christopher W; Rees, David C
2017-01-12
Fragment-based drug discovery (FBDD) is now well-established as a technology for generating new chemical leads and drugs. This Miniperspective provides a tabulated overview of the fragment-to-lead literature published in the year 2015, together with a commentary on trends observed across the FBDD field during this time. It is hoped that this tabulated summary will provide a useful point of reference for both FBDD practitioners and the wider medicinal chemistry community.
Green Nanochemistry Approach to Titanium Dioxide Nanoparticle, Dye- Sensitized Solar Cells
2012-06-01
of flavonoids , is commonly found in tissues of many different fruits and plants. In cell vacuoles, anthocyanins absorb light in the blue-green...their relative merits for application in green chemistry -based DSSCs. 10 5. References 1. O’Regan, B.; Grätzel, M. A Low-Cost, High-Efficiency...of Photochemistry and Photobiology A Chemistry 2011, 219, 188–194. 4. Fuleki, T.; Francis, F. J. Quantitative Methods for Anthocyanins
ERIC Educational Resources Information Center
Thomas, Gregory P.; McRobbie, Campbell J.
2002-01-01
Focuses on practices related to the use of a microcomputer-based laboratory (MBL) in a high school chemistry course in which students studied gases and kinetic theory. Reports that little or no higher order thinking was employed as students engaged in using the MBL and that some alternative conceptions were still evident. (Contains 42 references.)…
Lander, Michelle E; Fadely, Brian S; Gelatt, Thomas S; Rea, Lorrie D; Loughlin, Thomas R
2013-12-01
Blood chemistry and hematologic reference ranges are useful for population health assessment and establishing a baseline for future comparisons in the event of ecosystem changes due to natural or anthropogenic factors. The objectives of this study were to determine if there was any population spatial structure for blood variables of Steller sea lion (Eumetopias jubatus), an established sentinel species, and to report reference ranges for appropriate populations using standardized analyses. In addition to comparing reference ranges between populations with contrasting abundance trends, data were examined for evidence of disease or nutritional stress. From 1998 to 2011, blood samples were collected from 1,231 pups captured on 37 rookeries across their Alaskan range. Reference ranges are reported separately for the western and eastern distinct population segments (DPS) of Steller sea lion after cluster analysis and discriminant function analysis (DFA) supported underlying stock structure. Variables with greater loading scores for the DFA (creatinine, total protein, calcium, albumin, cholesterol, and alkaline phosphatase) also were greater for sea lions from the endangered western DPS, supporting previous studies that indicated pup condition in the west was not compromised during the first month postpartum. Differences between population segments were likely a result of ecological, physiological, or age related differences.
ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.
Flatland, Bente; Freeman, Kathleen P; Vap, Linda M; Harr, Kendal E
2013-12-01
Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting. © 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
McCain, Stephanie L; Flatland, Bente; Schumacher, Juergen P; Clarke Iii, Elsburgh O; Fry, Michael M
2010-12-01
Advantages of handheld and small bench-top biochemical analyzers include requirements for smaller sample volume and practicality for use in the field or in practices, but little has been published on the performance of these instruments compared with standard reference methods in analysis of reptilian blood. The aim of this study was to compare reptilian blood biochemical values obtained using the Abaxis VetScan Classic bench-top analyzer and a Heska i-STAT handheld analyzer with values obtained using a Roche Hitachi 911 chemical analyzer. Reptiles, including 14 bearded dragons (Pogona vitticeps), 4 blue-tongued skinks (Tiliqua gigas), 8 Burmese star tortoises (Geochelone platynota), 10 Indian star tortoises (Geochelone elegans), 5 red-tailed boas (Boa constrictor), and 5 Northern pine snakes (Pituophis melanoleucus melanoleucus), were manually restrained, and a single blood sample was obtained and divided for analysis. Results for concentrations of albumin, bile acids, calcium, glucose, phosphates, potassium, sodium, total protein, and uric acid and activities of aspartate aminotransferase and creatine kinase obtained from the VetScan Classic and Hitachi 911 were compared. Results for concentrations of chloride, glucose, potassium, and sodium obtained from the i-STAT and Hitachi 911 were compared. Compared with results from the Hitachi 911, those from the VetScan Classic and i-STAT had variable correlations, and constant or proportional bias was found for many analytes. Bile acid data could not be evaluated because results for 44 of 45 samples fell below the lower linearity limit of the VetScan Classic. Although the 2 portable instruments might provide measurements with clinical utility, there were significant differences compared with the reference analyzer, and development of analyzer-specific reference intervals is recommended. ©2010 American Society for Veterinary Clinical Pathology.
AVIRIS study of Death Valley evaporite deposits using least-squares band-fitting methods
NASA Technical Reports Server (NTRS)
Crowley, J. K.; Clark, R. N.
1992-01-01
Minerals found in playa evaporite deposits reflect the chemically diverse origins of ground waters in arid regions. Recently, it was discovered that many playa minerals exhibit diagnostic visible and near-infrared (0.4-2.5 micron) absorption bands that provide a remote sensing basis for observing important compositional details of desert ground water systems. The study of such systems is relevant to understanding solute acquisition, transport, and fractionation processes that are active in the subsurface. Observations of playa evaporites may also be useful for monitoring the hydrologic response of desert basins to changing climatic conditions on regional and global scales. Ongoing work using Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data to map evaporite minerals in the Death Valley salt pan is described. The AVIRIS data point to differences in inflow water chemistry in different parts of the Death Valley playa system and have led to the discovery of at least two new North American mineral occurrences. Seven segments of AVIRIS data were acquired over Death Valley on 31 July 1990, and were calibrated to reflectance by using the spectrum of a uniform area of alluvium near the salt pan. The calibrated data were subsequently analyzed by using least-squares spectral band-fitting methods, first described by Clark and others. In the band-fitting procedure, AVIRIS spectra are fit compared over selected wavelength intervals to a series of library reference spectra. Output images showing the degree of fit, band depth, and fit times the band depth are generated for each reference spectrum. The reference spectra used in the study included laboratory data for 35 pure evaporite spectra extracted from the AVIRIS image cube. Additional details of the band-fitting technique are provided by Clark and others elsewhere in this volume.
Fanelli, Flaminia; Gambineri, Alessandra; Belluomo, Ilaria; Repaci, Andrea; Di Lallo, Valentina Diana; Di Dalmazi, Guido; Mezzullo, Marco; Prontera, Olga; Cuomo, Gaia; Zanotti, Laura; Paccapelo, Alexandro; Morselli-Labate, Antonio Maria; Pagotto, Uberto; Pasquali, Renato
2013-07-01
Physiological transient imbalance typical of adolescence needs to be distinguished from hyperandrogenism-related dysfunction. The accurate determination of circulating androgens is the best indicator of hyperandrogenism. However, reliable reference intervals for adolescent and young women are not available. The aim of the study was to define androgen reference intervals in young women and to analyze the impact of the menstrual phase and ovulation efficiency over the androgen profile as assessed by reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique. Female high school students aged 16-19 years were included in the study. The study was performed on reference subjects properly selected among an unbiased population. Normal-weight, drug and disease free, eumenorrheic females with no signs of hyperandrogenism were included. The steroid hormone profile was determined by a validated in-house LC-MS/MS method. A statistical estimation of overall and menstrual phase-specific reference intervals was performed. A subgroup of anovulatory females was identified based on progesterone circulating levels. The impact of ovulation efficiency over hormonal profile was analyzed. A total of 159 females satisfied healthy criteria. Androgen levels did not vary according to menstrual phase, but a significantly higher upper reference limit was found for T in the luteal phase compared to the follicular phase. Higher T and androstenedione levels were observed in anovulatory compared to ovulatory females, paralleled by higher LH and FSH and lower 17-hydroxyprogesterone and 17β-estradiol levels. This is the first study providing LC-MS/MS-based, menstrual phase-specific reference intervals for the circulating androgen profile in young females. We identified a subgroup of anovulatory healthy females characterized by androgen imbalance.
Dzikamunhenga, R S; Griffith, R W; Hostetter, S; Fisher, P; Larson, W
2017-06-01
Chinese ring-necked pheasants ( Phasianus colchicus ) are commonly farmed in intensive operations for purposes such as meat production, hunting preserves, or research. Under these conditions, pheasants frequently suffer medical ailments such as bacterial, viral, and parasitic infections or nutritional or metabolic disorders. Relatively little scientific information exists regarding clinical pathology reference intervals (RIs) for farm-reared pheasants. The objective of this study was to determine RIs for hematologic and serum biochemical variables for Chinese ring-necked pheasants from Minnesota at 6 wk of age. Blood samples from 119 clinically healthy Chinese ring-necked pheasants were analyzed using standard techniques. Reference intervals were generated in Microsoft® Excel® 2013 (Microsoft, Redmond, WA) using Reference Value Advisor freeware version 2.1 (Microsoft). Ninety-five percent RIs were determined using nonparametric methods that followed Clinical and Laboratory Standards Institute guidelines. These RIs will be useful for the monitoring of health and diagnosis of disease in confined Chinese ring-necked pheasant populations that are approximately 6 wk old.
Ng, Chaan S.; Hobbs, Brian P.; Wei, Wei; Anderson, Ella F.; Herron, Delise H.; Yao, James C.; Chandler, Adam G.
2014-01-01
Objective To assess the effects of sampling interval (SI) of CT perfusion acquisitions on CT perfusion values in normal liver and liver metastases from neuroendocrine tumors. Methods CT perfusion in 16 patients with neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow, blood volume, mean transit time, permeability, and hepatic arterial fraction, for tumor and normal liver. CT perfusion values for the reference sampling interval of 0.5s (SI0.5) were compared with those of SI datasets of 1s, 2s, 3s and 4s, using mixed-effects model analyses. Results Increases in SI beyond 1s were associated with significant and increasing departures of CT perfusion parameters from reference values at SI0.5 (p≤0.0009). CT perfusion values deviated from reference with increasing uncertainty with increasing SIs. Findings for normal liver were concordant. Conclusion Increasing SIs beyond 1s yield significantly different CT perfusion parameter values compared to reference values at SI0.5. PMID:25626401
Considering User's Access Pattern in Multimedia File Systems
NASA Astrophysics Data System (ADS)
Cho, KyoungWoon; Ryu, YeonSeung; Won, Youjip; Koh, Kern
2002-12-01
Legacy buffer cache management schemes for multimedia server are grounded at the assumption that the application sequentially accesses the multimedia file. However, user access pattern may not be sequential in some circumstances, for example, in distance learning application, where the user may exploit the VCR-like function(rewind and play) of the system and accesses the particular segments of video repeatedly in the middle of sequential playback. Such a looping reference can cause a significant performance degradation of interval-based caching algorithms. And thus an appropriate buffer cache management scheme is required in order to deliver desirable performance even under the workload that exhibits looping reference behavior. We propose Adaptive Buffer cache Management(ABM) scheme which intelligently adapts to the file access characteristics. For each opened file, ABM applies either the LRU replacement or the interval-based caching depending on the Looping Reference Indicator, which indicates that how strong temporally localized access pattern is. According to our experiment, ABM exhibits better buffer cache miss ratio than interval-based caching or LRU, especially when the workload exhibits not only sequential but also looping reference property.
Versatile all-digital time interval measuring system
NASA Astrophysics Data System (ADS)
Vyhlidal, David; Cech, Miroslav
2011-06-01
This paper describes a design and performance of a versatile all-digital time interval measuring system. The measurement method is based on an interpolation principle. In this principle the time interval is first roughly digitized by a coarse counter driven by a high stability reference clock and the fractions between the clock periods are measured by two Time-to-Digital Converter chips TDC-GPX manufactured by Acam messelectronic. Control circuits allow programmable customization of the system to satisfy many applications such as laser range finding, event counting, or time-of-flight measurements in various physics experiments. The system has two reference clocks inputs and two independent channels for measuring start and stop events. Only one 40 MHz reference is required for the measurement. The second reference can be, for example, 1 PPS (Pulse per Second) signal from a GPS (Global Positioning System) to time tag events. Time intervals are measured using the highest resolution mode of the TDC-GPX chips. The resolution of each chip is software programmable and is PLL (Phase Locked Loop) stabilized against temperature and voltage variations. The system can achieve a timing resolution better than 15 ps rms with up to 90 kHz repetition rate. The time interval measurement range is from 0 ps up to 1 second. The power consumption of the whole system is 18 W including an embedded computer board and an LCD (Liquid Crystal Display) screen. The embedded computer controls the whole system, collects and evaluates measurement data and with the display provides a user interface. The system is implemented using commercially available components.
Schwacke, Lori H; Hall, Ailsa J; Townsend, Forrest I; Wells, Randall S; Hansen, Larry J; Hohn, Aleta A; Bossart, Gregory D; Fair, Patricia A; Rowles, Teresa K
2009-08-01
To develop robust reference intervals for hematologic and serum biochemical variables by use of data derived from free-ranging bottlenose dolphins (Tursiops truncatus) and examine potential variation in distributions of clinicopathologic values related to sampling sites' geographic locations. 255 free-ranging bottlenose dolphins. Data from samples collected during multiple bottlenose dolphin capture-release projects conducted at 4 southeastern US coastal locations in 2000 through 2006 were combined to determine reference intervals for 52 clinicopathologic variables. A nonparametric bootstrap approach was applied to estimate 95th percentiles and associated 90% confidence intervals; the need for partitioning by length and sex classes was determined by testing for differences in estimated thresholds with a bootstrap method. When appropriate, quantile regression was used to determine continuous functions for 95th percentiles dependent on length. The proportion of out-of-range samples for all clinicopathologic measurements was examined for each geographic site, and multivariate ANOVA was applied to further explore variation in leukocyte subgroups. A need for partitioning by length and sex classes was indicated for many clinicopathologic variables. For each geographic site, few significant deviations from expected number of out-of-range samples were detected. Although mean leukocyte counts did not vary among sites, differences in the mean counts for leukocyte subgroups were identified. Although differences in the centrality of distributions for some variables were detected, the 95th percentiles estimated from the pooled data were robust and applicable across geographic sites. The derived reference intervals provide critical information for conducting bottlenose dolphin population health studies.
Determination of strong ion gap in healthy dogs.
Fettig, Pamela K; Bailey, Dennis B; Gannon, Kristi M
2012-08-01
To determine and compare reference intervals of the strong ion gap (SIG) in a group of healthy dogs determined with 2 different equations. Prospective observational study. Tertiary referral and teaching hospital. Fifty-four healthy dogs. None. Serum biochemistry and blood gas analyses were performed for each dog. From these values, SIG was calculated using 2 different equations: SIG(1) = SID(a) {[Na (+)] + [K(+)] - [Cl(-)]+ [2 × Ca(2+)] + [2 × Mg(2+)] - [L-lactate]}- SID(e) {TCO(2) + A(-)} and SIG(2) = [albumin] × 4.9-anion gap. Reference intervals were established for each SIG equation using the mean ± 1.96 × standard deviation (SD). For SIG(1), the median was 7.13 mEq/L (range, 1.05-11.30 mEq/L) and the derived reference interval was 1.85-10.61 mEq/L. Median SIG(2) was -0.22 mEq/L (range, -5.34-6.61 mEq/L) and the mean SIG(2) was -0.09 mEq/L (95% confidence interval for the mean, -0.82-0.65 mEq/L). The derived reference interval was -5.36-5.18 mEq/L. The results of the SIG calculations were significantly different (P < 0.0001) between the 2 equations used. The 2 equations used to calculate SIG yielded significantly different results and cannot be used interchangeably. The authors believe SIG(2) to be a more accurate reflection of acid-base status in healthy dogs, and recommend that this calculation be used for future studies. © Veterinary Emergency and Critical Care Society 2012.
Beaulieu, Karen M.; Bell, Amanda H.; Coles, James F.
2012-01-01
Beginning in 1999, the U.S. Geological Survey National Water Quality Assessment Program investigated the effects of urban development on stream ecosystems in nine metropolitan study areas across the United States. In seven of these study areas, stream-chemistry samples were collected every other month for 1 year at 6 to 10 sites. Within a study area, the sites collectively represented a gradient of urban development from minimally to highly developed watersheds, based on the percentage of urban land cover; depending on study area, the land cover before urban development was either forested or agricultural. The stream-chemistry factors measured in the samples were total nitrogen, total phosphorus, chloride, and pesticide toxicity. These data were used to characterize the stream-chemistry factors in four ways (hereafter referred to as characterizations)—seasonal high-flow value, seasonal low-flow value, the median value (representing a single integrated value of the factor over the year), and the standard deviation of values (representing the variation of the factor over the year). Aquatic macroinvertebrate communities were sampled at each site to infer the biological condition of the stream based on the relative sensitivity of the community to environmental stressors. A Spearman correlation analysis was used to evaluate relations between (1) urban development and each characterization of the stream-chemistry factors and (2) the biological condition of a stream and the different characterizations of chloride and pesticide toxicity. Overall, the study areas where the land cover before urban development was primarily forested had a greater number of moderate and strong relations compared with the study areas where the land cover before urban development was primarily agriculture; this was true when urban development was correlated with the stream-chemistry factors (except chloride) and when chloride and pesticide toxicity was correlated with the biological condition. Except for primarily phosphorus in two study areas, stream-chemistry factors generally increased with urban development, and among the different characterizations, the median value typically indicated the strongest relations. The variation in stream-chemistry factors throughout the year generally increased with urban development, indicating that water quality became less consistent as watersheds were developed. In study areas with high annual snow fall, the variation in chloride concentrations throughout the year was particularly strongly related to urban development, likely a result of road salt applications during the winter. The relations of the biological condition to chloride and pesticide toxicity were calculated irrespective of urban development, but the overall results indicated that the relations were still stronger in the study areas that had been forested before urban development. The weaker relations in the study areas that had been agricultural before urban development were likely the results of biological communities having been degraded from agricultural practices in the watersheds. Collectively, these results indicated that, compared with sampling a stream at a single point in time, sampling at regular intervals during a year may provide a more representative measure of water quality, especially in the areas of high urban development where water quality fluctuated more widely between samples. Furthermore, the use of "integrated" values of stream chemistry factors may be more appropriate when assessing relations to the biological condition of a stream because the taxa composition of a biological community typically reflects the water-quality conditions over time.
Chemistry, Characterization and Processing of IMC Curing Polymers.
1983-07-01
example, nitronium hexafluorosilicate (Ref- erence 110), nitronium hexafluorophosphate (Reference 111) and nitronium trifluorometh- anesulfonate(triflate...CCLtoo) "C The dilithio compound underwent lithium -halogen exchange instead of displacement with bromophenylacetylene (Reference 129) due to the...positive character of the bromine on l-bromo-2-phenylacetylene. The reaction product of the lithium -bromine exchange reaction ൭ was identified as 1,4
ERIC Educational Resources Information Center
Zielinski, Theresa Julia; Brooks, David W.; Crippen, Kent J.; March, Joe L.
2001-01-01
Discusses using time effectively in chemistry instruction, planning instruction to compete for students' time, and whether the time needed for expertise will increase or decrease over the next few years. (Contains 13 references.) (ASK)
The taxonomy, biology and chemistry of the fungal Pestalotiopsis genus.
Yang, Xiao-Long; Zhang, Jing-Ze; Luo, Du-Qiang
2012-06-01
A growing body of evidence indicates that the Pestalotiopsis genus represents a huge and largely untapped resource of natural products with chemical structures that have been optimized by evolution for biological and ecological relevance. So far, 196 secondary metabolites have been encountered in this genus. This review systematically surveys the taxonomy, biology and chemistry of the Pestalotiopsis genus. It also summarises the biosynthetic relationships and chemical synthesis of metabolites from this genus. There are 184 references.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krishnamoorthy, Sriram; Daily, Jeffrey A.; Vishnu, Abhinav
2015-11-01
Global Arrays (GA) is a distributed-memory programming model that allows for shared-memory-style programming combined with one-sided communication, to create a set of tools that combine high performance with ease-of-use. GA exposes a relatively straightforward programming abstraction, while supporting fully-distributed data structures, locality of reference, and high-performance communication. GA was originally formulated in the early 1990’s to provide a communication layer for the Northwest Chemistry (NWChem) suite of chemistry modeling codes that was being developed concurrently.
Fundamental and applied aspects of the chemistry of radioactive iodine in gas and aqueous media
NASA Astrophysics Data System (ADS)
Kulyukhin, Sergei A.
2012-10-01
The results of investigations carried out in the past 15-20 years in the chemistry of radioactive iodine in the gas phase and in aqueous media of various compositions are described systematically and analyzed. The prospects for practical application of the obtained data in various fields of nuclear power industry including accidents at nuclear power plants and enterprises engaged in spent nuclear fuel reprocessing are estimated. The bibliography includes 206 references.
Chemical calculations on Cray computers
NASA Technical Reports Server (NTRS)
Taylor, Peter R.; Bauschlicher, Charles W., Jr.; Schwenke, David W.
1989-01-01
The influence of recent developments in supercomputing on computational chemistry is discussed with particular reference to Cray computers and their pipelined vector/limited parallel architectures. After reviewing Cray hardware and software the performance of different elementary program structures are examined, and effective methods for improving program performance are outlined. The computational strategies appropriate for obtaining optimum performance in applications to quantum chemistry and dynamics are discussed. Finally, some discussion is given of new developments and future hardware and software improvements.
NASA Astrophysics Data System (ADS)
Jöckel, Patrick; Tost, Holger; Pozzer, Andrea; Kunze, Markus; Kirner, Oliver; Brenninkmeijer, Carl A. M.; Brinkop, Sabine; Cai, Duy S.; Dyroff, Christoph; Eckstein, Johannes; Frank, Franziska; Garny, Hella; Gottschaldt, Klaus-Dirk; Graf, Phoebe; Grewe, Volker; Kerkweg, Astrid; Kern, Bastian; Matthes, Sigrun; Mertens, Mariano; Meul, Stefanie; Neumaier, Marco; Nützel, Matthias; Oberländer-Hayn, Sophie; Ruhnke, Roland; Runde, Theresa; Sander, Rolf; Scharffe, Dieter; Zahn, Andreas
2016-03-01
Three types of reference simulations, as recommended by the Chemistry-Climate Model Initiative (CCMI), have been performed with version 2.51 of the European Centre for Medium-Range Weather Forecasts - Hamburg (ECHAM)/Modular Earth Submodel System (MESSy) Atmospheric Chemistry (EMAC) model: hindcast simulations (1950-2011), hindcast simulations with specified dynamics (1979-2013), i.e. nudged towards ERA-Interim reanalysis data, and combined hindcast and projection simulations (1950-2100). The manuscript summarizes the updates of the model system and details the different model set-ups used, including the on-line calculated diagnostics. Simulations have been performed with two different nudging set-ups, with and without interactive tropospheric aerosol, and with and without a coupled ocean model. Two different vertical resolutions have been applied. The on-line calculated sources and sinks of reactive species are quantified and a first evaluation of the simulation results from a global perspective is provided as a quality check of the data. The focus is on the intercomparison of the different model set-ups. The simulation data will become publicly available via CCMI and the Climate and Environmental Retrieval and Archive (CERA) database of the German Climate Computing Centre (DKRZ). This manuscript is intended to serve as an extensive reference for further analyses of the Earth System Chemistry integrated Modelling (ESCiMo) simulations.
Genetics Home Reference: Romano-Ward syndrome
... part of the heartbeat known as the QT interval is abnormally long. Abnormalities in the time it ... those types that involve only a long QT interval without other abnormalities. Related Information What does it ...
Genetics Home Reference: ankyrin-B syndrome
... beats, which is known as a prolonged QT interval (long QT). Some affected individuals have impaired progression ( ... sudden death. When associated with a prolonged QT interval, the condition is sometimes classified as long QT ...
Eisenhofer, Graeme; Peitzsch, Mirko; Kaden, Denise; Langton, Katharina; Pamporaki, Christina; Masjkur, Jimmy; Tsatsaronis, George; Mangelis, Anastasios; Williams, Tracy A; Reincke, Martin; Lenders, Jacques W M; Bornstein, Stefan R
2017-07-01
Mass spectrometric-based measurements of the steroid metabolome have been introduced to diagnose disorders featuring abnormal steroidogenesis. Defined reference intervals are important for interpreting such data. Liquid chromatography-tandem mass spectrometry was used to establish reference intervals for 16 steroids (pregnenolone, progesterone, 11-deoxycorticosterone, corticosterone, aldosterone, 18-oxocortisol, 18-hydroxycortisol, 17-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, cortisol, cortisone, dehydroepiandrosterone, dehydroepiandrosterone-sulfate, androstenedione, testosterone) measured in plasma from 525 volunteers with (n=227) and without (n=298) hypertension, including 68 women on oral contraceptives. Women showed variable plasma concentrations of several steroids associated with menstrual cycle phase, menopause and oral contraceptive use. Progesterone was higher in females than males, but most other steroids were higher in males than females and almost all declined with advancing age. Using models that corrected for age and gender, body mass index showed weak negative relationships with corticosterone, 21-deoxycortisol, cortisol, cortisone, testosterone, progesterone, 17-hydroxyprogesterone and 11-deoxycorticosterone, but a positive relationship with 18-hydroxycortisol. Hypertensives and normotensives showed negligible differences in plasma concentrations of steroids. Age and gender are the most important variables for plasma steroid reference intervals, which have been established here according to those variables for a panel of 16 steroids primarily useful for diagnosis and subtyping of patients with endocrine hypertension. Copyright © 2017. Published by Elsevier B.V.
Loh, Tze Ping; Antoniou, Georgia; Baghurst, Peter; Metz, Michael P
2014-06-01
Age-specific paediatric reference intervals are used in interpretation of laboratory results. However, interpretation may be problematic when a child just crosses an age bracket and the difference between the original and the subsequent age-specific reference interval is large. Moreover, details about the physiological changes with age may be masked. For the 12 months ending 30 September 2013, results of 16 common clinical biochemistry tests of ambulatory paediatric patients aged 0-19, requested by primary care physicians, were retrospectively collected in a large pathology service, and used to construct smoothed centile charts using a penalised maximum likelihood method. From the developed centile charts, the concentrations of sodium, bicarbonate, creatinine, urate, total protein, and albumin all increased with increasing age of the children. In contrast, the concentrations of potassium, chloride, anion gap, calcium, phosphate and lactate dehydrogenase decreased with increasing age of the children. Changes in the concentrations of urea, alkaline phosphatase, glucose, and total cholesterol varied by age. Generally, the boys and girls shared similar trend patterns until 10-15 years of age, when variations in the age of onset of puberty and development caused the trends of some biochemical measures to differ. The paediatric biochemistry centile charts are intuitive tools to use. They complement age-specific reference intervals in the tracking, interpretation and discussion of laboratory results. They also enhance the understanding of underlying physiological changes in biochemistry in children.
Liu, Xiao-Ping; Gao, Bao-Zhen; Han, Feng-Qing; Fang, Zhi-Yuan; Yang, Li-Mei; Zhuang, Mu; Lv, Hong-Hao; Liu, Yu-Mei; Li, Zhan-Sheng; Cai, Cheng-Cheng; Yu, Hai-Long; Li, Zhi-Yuan; Zhang, Yang-Yong
2017-03-14
Due to its variegated and colorful leaves, ornamental kale (Brassica oleracea L. var. acephala) has become a popular ornamental plant. In this study, we report the fine mapping and analysis of a candidate purple leaf gene using a backcross population and an F 2 population derived from two parental lines: W1827 (with white leaves) and P1835 (with purple leaves). Genetic analysis indicated that the purple leaf trait is controlled by a single dominant gene, which we named BoPr. Using markers developed based on the reference genome '02-12', the BoPr gene was preliminarily mapped to a 280-kb interval of chromosome C09, with flanking markers M17 and BoID4714 at genetic distances of 4.3 cM and 1.5 cM, respectively. The recombination rate within this interval is almost 12 times higher than the usual level, which could be caused by assembly error for reference genome '02-12' at this interval. Primers were designed based on 'TO1000', another B. oleracea reference genome. Among the newly designed InDel markers, BRID485 and BRID490 were found to be the closest to BoPr, flanking the gene at genetic distances of 0.1 cM and 0.2 cM, respectively; the interval between the two markers is 44.8 kb (reference genome 'TO1000'). Seven annotated genes are located within the 44.8 kb genomic region, of which only Bo9g058630 shows high homology to AT5G42800 (dihydroflavonol reductase), which was identified as a candidate gene for BoPr. Blast analysis revealed that this 44.8 kb interval is located on an unanchored scaffold (Scaffold000035_P2) of '02-12', confirming the existence of assembly error at the interval between M17 and BoID4714 for reference genome '02-12'. This study identified a candidate gene for BoPr and lays a foundation for the cloning and functional analysis of this gene.
Experiments for Modern Introductory Chemistry.
ERIC Educational Resources Information Center
Kildahl, Nicholas; Berka, Ladislav H.
1995-01-01
Presents a headspace gas chromatography experiment that enables discovery of the temperature dependence of the vapor pressure of a pure liquid. Illustrates liquid-vapor phase equilibrium of pure liquids. Contains 22 references. (JRH)
Sarkar, Rajarshi
2013-08-23
Although TSH measurement by electrochemiluminescence immunoassay has become commonplace in India, significant discrepancy has been observed on interpretation of the test results when the manufacturer supplied biological reference interval (BRI) criteria were applied. This report determined whether the manufacturer's BRI (Roche Cobas) is transferable to the Indian population. Three hundred seventy-eight age- and sex-matched healthy subjects were selected from an urban Indian population. TSH reference measurements were acquired, and the reference data were statistically analysed. BRI of the Indian urban reference population was determined by non-parametric means. BRI was found to be 1.134 to 7.280μIU/ml. BRI thus calculated was found to be significantly different from that mentioned by the manufacturer (0.27 to 4.20μIU/ml), which, needless to mention, has profound clinical implications in this part of the globe. Copyright © 2013 Elsevier B.V. All rights reserved.
Aerosol slurry samples were collected at 30-min intervals for sequential 1-month periods at each of two sites (Sydney and "Dairy") in the Tampa Bay area during the 2002 Bay Regional Atmospheric Chemistry Experiment using the University of Maryland Semicontinuous Elements in Aeros...
Schaal, T P; Arango, J; Wolc, A; Brady, J V; Fulton, J E; Rubinoff, I; Ehr, I J; Persia, M E; O'Sullivan, N P
2016-02-01
Venous blood gas and chemistry reference ranges were determined for commercial Hy-Line W-36 pullets and laying hens utilizing the portable i-STAT®1 analyzer and CG8+ cartridges. A total of 632 samples were analyzed from birds between 4 and 110 wk of age. Reference ranges were established for pullets (4 to 15 wk), first cycle laying hens (20 to 68 wk), and second cycle (post molt) laying hens (70 to 110 wk) for the following traits: sodium (Na mmol/L), potassium (K mmol/L), ionized calcium (iCa mmol/L), glucose (Glu mg/dl), hematocrit (Hct% Packed Cell Volume [PCV]), pH, partial pressure carbon dioxide (PCO2 mm Hg), partial pressure oxygen (PO2 mm Hg), total concentration carbon dioxide (TCO2 mmol/L), bicarbonate (HCO3 mmol/L), base excess (BE mmol/L), oxygen saturation (sO2%), and hemoglobin (Hb g/dl). Data were analyzed using ANOVA to investigate the effect of production status as categorized by bird age. Trait relationships were evaluated by linear correlation and their spectral decomposition. All traits differed significantly among pullets and mature laying hens in both first and second lay cycles. Levels for K, iCa, Hct, pH, TCO2, HCO3, BE, sO2, and Hb differed significantly between first cycle and second cycle laying hens. Many venous blood gas and chemistry parameters were significantly correlated. The first 3 eigenvalues explained ∼2/3 of total variation. The first 2 principal components (PC) explained 51% of the total variation and indicated acid-balance and relationship between blood O2 and CO2. The third PC explained 16% of variation and seems to be related to blood iCa. Establishing reference ranges for pullet and laying hen blood gas and chemistry with the i-STAT®1 handheld unit provides a mechanism to further investigate pullet and layer physiology, evaluate metabolic disturbances, and may potentially serve as a means to select breeder candidates with optimal blood gas or chemistry levels on-farm. © The Author 2015. Published by Oxford University Press on behalf of the Poultry Science Association.
Mistry, Hiten D; Eisele, Nicole; Escher, Geneviève; Dick, Bernhard; Surbek, Daniel; Delles, Christian; Currie, Gemma; Schlembach, Dietmar; Mohaupt, Markus G; Gennari-Moser, Carine
2015-09-04
Normal pregnancy depends on pronounced adaptations in steroid hormone concentrations. Although in recent years, the understanding of these hormones in pregnancy has improved, the interpretation is hampered by insufficient reference values. Our aim was to establish gestation-specific reference intervals for spot urinary steroid hormone levels in normal singleton pregnancies and 6 weeks postpartum. Cross-sectional multicentre observational study. Women recruited between 2008 and 2013 at 3 University Hospitals in Switzerland (Bern), Scotland (Glasgow) and Austria (Graz). Spot urine was collected from healthy women undergoing a normal pregnancy (age, 16-45 years; mean, 31 years) attending routine antenatal clinics at gestation weeks 11, 20, and 28 and approximately 6 weeks postpartum. Urine steroid hormone levels were analysed using gas-chromatography mass spectrometry. Creatinine was also measured by routine analysis and used for normalisation. From the results, a reference interval was calculated for each hormone metabolite at each trimester and 6 weeks postpartum. Changes in these concentrations between trimesters and postpartum were also observed for several steroid hormones and followed changes proposed for index steroid hormones. Normal gestation-specific reference values for spot urinary steroid hormones throughout pregnancy and early postpartum are now available to facilitate clinical management and research approaches to steroid hormone metabolism in pregnancy and the early postpartum period.
Liu, Jianhua; Yu, Xiaojun; Xia, Meng; Cai, Hong; Cheng, Guixue; Wu, Lina; Li, Qiang; Zhang, Ying; Sheng, Mengyuan; Liu, Yong; Qin, Xiaosong
2017-04-01
A laboratory- and region-specific trimester-related reference interval for thyroid hormone assessment of pregnant women was recommended. Whether the division by trimester is suitable requires verification. Here, we tried to establish appropriate reference intervals of thyroid-related hormones and antibodies for normal pregnant women in Northeast China. A total of 947 pregnant women who underwent routine prenatal care were grouped via two methods. The first method entailed division by trimester: stages T1, T2, and T3. The second method entailed dividing T1, T2, and T3 stages into two stages each: T1-1, T1-2, T2-1, T2-2, T3-1, and T3-2. Serum levels of TSH, FT3, FT4, Anti-TPO, and Anti-TG were measured by three detection systems. No significant differences were found in TSH values between T1-1 group and the non-pregnant women group. However, the TSH value of the T1-1 group was significantly higher than that of T1-2 group (P<0.05). The TSH values in stage T3-2 increased significantly compared to those in stage T3-1 measured by three different assays (P<0.05). FT4 and FT3 values decreased significantly in the T2-1 and T2-2 stages compared to the previous stage (P<0.05). The serum levels of Anti-TPO and Anti-TG were not having significant differences between the six stages. The diagnosis and treatment of thyroid dysfunction during pregnancy should base on pregnancy- and method-specific reference intervals. More detailed staging is required to assess the thyroid function of pregnant women before 20 gestational weeks. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Saw, S; Aw, T C
2000-11-01
Cancer of the prostate is the sixth most frequently found cancer in Singapore. Prostate-specific antigen (PSA) is the most clinically useful tumour marker available today for the diagnosis and management of prostate cancer. To enhance the value of PSA as a screening test we developed age-specific intervals for our ethnic population. The measurement of free PSA was included in the study to calculate the free:total ratio which enhances the differential diagnosis of prostate cancer from benign prostatic hyperplasia or prostatitis. The total PSA upper limits of 10-year intervals, beginning at 30-years-old, were 1.4, 1.7, 2.3, 4.0, 6.3 and 6.6 microg/l. Free PSA cut-off limits were 0.4, 0.5, 0.5, 1.0, 1.5 and 1.6 microg/l. The free:total ratio of PSA was not age dependent. Abbott AxSym standardised their calibration material for both free and total PSA assays with the Stanford 90:10 reference material. This laboratory has implemented these age-specific reference intervals and are currently following up their pick-up rate in the detection of prostate cancer.
Morton, Michael J; Laffoon, Susan W
2008-06-01
This study extends the market mapping concept introduced by Counts et al. (Counts, M.E., Hsu, F.S., Tewes, F.J., 2006. Development of a commercial cigarette "market map" comparison methodology for evaluating new or non-conventional cigarettes. Regul. Toxicol. Pharmacol. 46, 225-242) to include both temporal cigarette and testing variation and also machine smoking with more intense puffing parameters, as defined by the Massachusetts Department of Public Health (MDPH). The study was conducted over a two year period and involved a total of 23 different commercial cigarette brands from the U.S. marketplace. Market mapping prediction intervals were developed for 40 mainstream cigarette smoke constituents and the potential utility of the market map as a comparison tool for new brands was demonstrated. The over-time character of the data allowed for the variance structure of the smoke constituents to be more completely characterized than is possible with one-time sample data. The variance was partitioned among brand-to-brand differences, temporal differences, and the remaining residual variation using a mixed random and fixed effects model. It was shown that a conventional weighted least squares model typically gave similar prediction intervals to those of the more complicated mixed model. For most constituents there was less difference in the prediction intervals calculated from over-time samples and those calculated from one-time samples than had been anticipated. One-time sample maps may be adequate for many purposes if the user is aware of their limitations. Cigarette tobacco fillers were analyzed for nitrate, nicotine, tobacco-specific nitrosamines, ammonia, chlorogenic acid, and reducing sugars. The filler information was used to improve predicting relationships for several of the smoke constituents, and it was concluded that the effects of filler chemistry on smoke chemistry were partial explanations of the observed brand-to-brand variation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, M.D.
Analytical Chemistry of PCBs offers a review of physical, chemical, commercial, environmental and biological properties of PCBs. It also defines and discusses six discrete steps of analysis: sampling, extraction, cleanup, determination, data reduction, and quality assurance. The final chapter provides a discussion on collaborative testing - the ultimate step in method evaluation. Dr. Erickson also provides a bibliography of over 1200 references, critical reviews of primary literature, and five appendices which present ancillary material on PCB nomen-clature, physical properties, composition of commercial mixtures, mass spectra characteristics, and PGC/ECD chromatograms.
Pim-1: A Molecular Target to Modulate Cellular Resistance to Therapy in Prostate Cancer
2007-10-01
submitted to the Journal of Biological Chemistry . BODY We will outline our progress through reference to the specific aims described above. The first... Chemistry (see manuscript in appendix). The goal of specific aim #2 was to define pathways through which the PIM1 kinase could activate NFkB...or with three other flavonoids , has been determined. We have also shown that quercetagetin is able to inhibit the activity of the PIM1 kinase in
Sustainable Chemistry Research and Development Act of 2014
Sen. Coons, Christopher A. [D-DE
2014-09-18
Senate - 09/18/2014 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Over the last several years, there has been increased pressure to utilize novel technologies derived from computational chemistry, molecular biology and systems biology in toxicological risk assessment. This new area has been referred to as "Computational Toxicology". Our resear...
Genetics Home Reference: Jervell and Lange-Nielsen syndrome
... KCNQ1 or KCNE1 mutation have a long QT interval with related heart abnormalities, but their hearing is ... disease Jervell-Lange Nielsen syndrome JLNS prolonged QT interval in EKG and sudden death surdo-cardiac syndrome ...
Microbial isoprenoid production: an example of green chemistry through metabolic engineering.
Maury, Jérôme; Asadollahi, Mohammad A; Møller, Kasper; Clark, Anthony; Nielsen, Jens
2005-01-01
Saving energy, cost efficiency, producing less waste, improving the biodegradability of products, potential for producing novel and complex molecules with improved properties, and reducing the dependency on fossil fuels as raw materials are the main advantages of using biotechnological processes to produce chemicals. Such processes are often referred to as green chemistry or white biotechnology. Metabolic engineering, which permits the rational design of cell factories using directed genetic modifications, is an indispensable strategy for expanding green chemistry. In this chapter, the benefits of using metabolic engineering approaches for the development of green chemistry are illustrated by the recent advances in microbial production of isoprenoids, a diverse and important group of natural compounds with numerous existing and potential commercial applications. Accumulated knowledge on the metabolic pathways leading to the synthesis of the principal precursors of isoprenoids is reviewed, and recent investigations into isoprenoid production using engineered cell factories are described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tilmes, Simone; Lamarque, Jean -Francois; Emmons, Louisa K.
The Community Earth System Model (CESM1) CAM4-chem has been used to perform the Chemistry Climate Model Initiative (CCMI) reference and sensitivity simulations. In this model, the Community Atmospheric Model version 4 (CAM4) is fully coupled to tropospheric and stratospheric chemistry. Details and specifics of each configuration, including new developments and improvements are described. CESM1 CAM4-chem is a low-top model that reaches up to approximately 40 km and uses a horizontal resolution of 1.9° latitude and 2.5° longitude. For the specified dynamics experiments, the model is nudged to Modern-Era Retrospective Analysis for Research and Applications (MERRA) reanalysis. We summarize the performance ofmore » the three reference simulations suggested by CCMI, with a focus on the last 15 years of the simulation when most observations are available. Comparisons with selected data sets are employed to demonstrate the general performance of the model. We highlight new data sets that are suited for multi-model evaluation studies. Most important improvements of the model are the treatment of stratospheric aerosols and the corresponding adjustments for radiation and optics, the updated chemistry scheme including improved polar chemistry and stratospheric dynamics and improved dry deposition rates. These updates lead to a very good representation of tropospheric ozone within 20 % of values from available observations for most regions. In particular, the trend and magnitude of surface ozone is much improved compared to earlier versions of the model. Furthermore, stratospheric column ozone of the Southern Hemisphere in winter and spring is reasonably well represented. In conclusion, all experiments still underestimate CO most significantly in Northern Hemisphere spring and show a significant underestimation of hydrocarbons based on surface observations.« less
Tilmes, Simone; Lamarque, Jean -Francois; Emmons, Louisa K.; ...
2016-05-20
The Community Earth System Model (CESM1) CAM4-chem has been used to perform the Chemistry Climate Model Initiative (CCMI) reference and sensitivity simulations. In this model, the Community Atmospheric Model version 4 (CAM4) is fully coupled to tropospheric and stratospheric chemistry. Details and specifics of each configuration, including new developments and improvements are described. CESM1 CAM4-chem is a low-top model that reaches up to approximately 40 km and uses a horizontal resolution of 1.9° latitude and 2.5° longitude. For the specified dynamics experiments, the model is nudged to Modern-Era Retrospective Analysis for Research and Applications (MERRA) reanalysis. We summarize the performance ofmore » the three reference simulations suggested by CCMI, with a focus on the last 15 years of the simulation when most observations are available. Comparisons with selected data sets are employed to demonstrate the general performance of the model. We highlight new data sets that are suited for multi-model evaluation studies. Most important improvements of the model are the treatment of stratospheric aerosols and the corresponding adjustments for radiation and optics, the updated chemistry scheme including improved polar chemistry and stratospheric dynamics and improved dry deposition rates. These updates lead to a very good representation of tropospheric ozone within 20 % of values from available observations for most regions. In particular, the trend and magnitude of surface ozone is much improved compared to earlier versions of the model. Furthermore, stratospheric column ozone of the Southern Hemisphere in winter and spring is reasonably well represented. In conclusion, all experiments still underestimate CO most significantly in Northern Hemisphere spring and show a significant underestimation of hydrocarbons based on surface observations.« less
Hubbell, Joel M.; Sisson, James B.
2001-01-01
A deep tensiometer is configured with an outer guide tube having a vented interval along a perforate section at its lower end, which is isolated from atmospheric pressure at or above grade. A transducer having a monitoring port and a reference port is located within a coaxial inner guide tube. The reference port of the transducer is open to the vented interval of the outer guide tube, which has the same gas pressure as in the sediment surrounding the tensiometer. The reference side of the pressure transducer is thus isolated from the effects of atmospheric pressure changes and relative to pressure changes in the material surrounding the tensiometer measurement location and so it is automatically compensated for such pressure changes.
A Thematic Review of Studies into the Effectiveness of Context-Based Chemistry Curricula
NASA Astrophysics Data System (ADS)
Ültay, Neslihan; Çalık, Muammer
2012-12-01
Context-based chemistry education aims at making connections between real life and the scientific content of chemistry courses. The purpose of this study was to evaluate context-based chemistry studies. In looking for the context-based chemistry studies, the authors entered the keywords `context-based', `contextual learning' and `chemistry education' in well-known databases (i.e. Academic Search Complete, Education Research Complete, ERIC, Springer LINK Contemporary). Further, in case the computer search by key words may have missed a rather substantial part of the important literature in the area, the authors also conducted a hand search of the related journals. To present a detailed thematic review of context-based chemistry studies, a matrix was used to summarize the findings by focusing on insights derived from the related studies. The matrix incorporates the following themes: needs, aims, methodologies, general knowledge claims, and implications for teaching and learning, implications for curriculum development and suggestions for future research. The general knowledge claims investigated in this paper were: (a) positive effects of the context-based chemistry studies; (b) caveats, both are examined in terms of students' attitudes and students' understanding/cognition. Implications were investigated for practice in context- based chemistry studies, for future research in context- based chemistry studies, and for curriculum developers in context- based chemistry studies. Teachers of context-based courses claimed that the application of the context-based learning approach in chemistry education improved students' motivation and interest in the subject. This seems to have generated an increase in the number of the students who wish to continue chemistry education at higher levels. However, despite the fact that the majority of the studies have reported advantages of context-based chemistry studies, some of them have also referred to pitfalls, i.e. dominant structure of out-of-school learning, tough nature of some chemistry topics, and teacher anxiety of lower-ability students.
Isaza, Ramiro; Wiedner, Ellen; Hiser, Sarah; Cray, Carolyn
2014-09-01
Acute phase protein (APP) immunoassays and serum protein electrophoresis (SPEP) are assays for evaluating the inflammatory response and have use as diagnostic tools in a variety of species. Acute phase proteins are markers of inflammation that are highly conserved across different species while SPEP separates and quantifies serum protein fractions based on their physical properties. In the current study, serum samples from 35 clinically healthy Asian elephants (Elephas maximus) were analyzed using automated assays for C-reactive protein, serum amyloid A, and haptoglobin and SPEP. Robust methods were used to generate reference intervals for the APPs: C-reactive protein (1.3-12.8 mg/l), serum amyloid A (0-47.5 mg/l), and haptoglobin (0-1.10 mg/ml). In addition, SPEP was performed on these samples to establish reference intervals for each protein fraction. A combination of APPs and SPEP measurements are valuable adjunctive diagnostic tools in elephant health care. © 2014 The Author(s).
MinION Analysis and Reference Consortium: Phase 2 data release and analysis of R9.0 chemistry.
Jain, Miten; Tyson, John R; Loose, Matthew; Ip, Camilla L C; Eccles, David A; O'Grady, Justin; Malla, Sunir; Leggett, Richard M; Wallerman, Ola; Jansen, Hans J; Zalunin, Vadim; Birney, Ewan; Brown, Bonnie L; Snutch, Terrance P; Olsen, Hugh E
2017-01-01
Long-read sequencing is rapidly evolving and reshaping the suite of opportunities for genomic analysis. For the MinION in particular, as both the platform and chemistry develop, the user community requires reference data to set performance expectations and maximally exploit third-generation sequencing. We performed an analysis of MinION data derived from whole genome sequencing of Escherichia coli K-12 using the R9.0 chemistry, comparing the results with the older R7.3 chemistry. We computed the error-rate estimates for insertions, deletions, and mismatches in MinION reads. Run-time characteristics of the flow cell and run scripts for R9.0 were similar to those observed for R7.3 chemistry, but with an 8-fold increase in bases per second (from 30 bps in R7.3 and SQK-MAP005 library preparation, to 250 bps in R9.0) processed by individual nanopores, and less drop-off in yield over time. The 2-dimensional ("2D") N50 read length was unchanged from the prior chemistry. Using the proportion of alignable reads as a measure of base-call accuracy, 99.9% of "pass" template reads from 1-dimensional ("1D") experiments were mappable and ~97% from 2D experiments. The median identity of reads was ~89% for 1D and ~94% for 2D experiments. The total error rate (miscall + insertion + deletion ) decreased for 2D "pass" reads from 9.1% in R7.3 to 7.5% in R9.0 and for template "pass" reads from 26.7% in R7.3 to 14.5% in R9.0. These Phase 2 MinION experiments serve as a baseline by providing estimates for read quality, throughput, and mappability. The datasets further enable the development of bioinformatic tools tailored to the new R9.0 chemistry and the design of novel biological applications for this technology. K: thousand, Kb: kilobase (one thousand base pairs), M: million, Mb: megabase (one million base pairs), Gb: gigabase (one billion base pairs).
Quality improvement on chemistry practicum courses through implementation of 5E learning cycle
NASA Astrophysics Data System (ADS)
Merdekawati, Krisna
2017-03-01
Two of bachelor of chemical education's competences are having practical skills and mastering chemistry material. Practicum courses are organized to support the competency achievement. Based on observation and evaluation, many problems were found in the implementation of practicum courses. Preliminary study indicated that 5E Learning Cycle can be used as an alternative solution in order to improve the quality of chemistry practicum course. The 5E Learning Cycle can provide positive influence on the achievement of the competence, laboratory skills, and students' understanding. The aim of the research was to describe the feasibility of implementation of 5E Learning Cycle on chemistry practicum courses. The research was based on phenomenology method in qualitative approach. The participants of the research were 5 person of chemistry laboratory manager (lecturers at chemistry and chemistry education department). They concluded that the 5E Learning Cycle could be implemented to improve the quality of the chemistry practicum courses. Practicum guides and assistant competences were organized to support the implementation of 5E Learning Cycle. It needed training for assistants to understand and implement in the stages of 5E Learning Cycle. Preparation of practical guidelines referred to the stages of 5E Learning Cycle, started with the introduction of contextual and applicable materials, then followed with work procedures that accommodate the stage of engagement, exploration, explanation, extension, and evaluation
Self-calibrating threshold detector
NASA Technical Reports Server (NTRS)
Barnes, J. R.; Huang, M. Y. (Inventor)
1980-01-01
A self calibrating threshold detector comprises a single demodulating channel which includes a mixer having one input receiving the incoming signal and another input receiving a local replica code. During a short time interval, an incorrect local code is applied to the mixer to incorrectly demodulate the incoming signal and to provide a reference level that calibrates the noise propagating through the channel. A sample and hold circuit is coupled to the channel for storing a sample of the reference level. During a relatively long time interval, the correct replica code provides an output level which ranges between the reference level and a maximum level that represents incoming signal presence and synchronism with the replica code. A summer substracts the stored sample reference from the output level to provide a resultant difference signal indicative of the acquisition of the expected signal.
Germer, Jeffrey J.; Ankoudinova, Irina; Belousov, Yevgeniy S.; Mahoney, Walt; Dong, Chen; Meng, Jihong; Mandrekar, Jayawant N.
2017-01-01
ABSTRACT Hepatitis E virus (HEV) has emerged as a cause of chronic hepatitis among immunocompromised patients. Molecular assays have become important tools for the diagnosis and management of these chronically infected patients. A real-time reverse transcription-quantitative PCR (RT-qPCR) assay utilizing Pleiades probe chemistry and an RNA internal control for the simultaneous detection and quantification of HEV RNA in human serum was developed based on an adaptation of a previously described and broadly reactive primer set targeting the overlapping open reading frame 2/3 (ORF2/3) nucleotide sequence of HEV. A chimeric bovine viral diarrhea virus construct containing an HEV RNA insert (SynTura HEV) was developed, value assigned with the first World Health Organization (WHO) international standard for HEV RNA (code 6329/10), and used to prepare working assay calibrators and controls, which supported an assay quantification range of 100 to 5,000,000 IU/ml. The analytical sensitivity (95% detection rate) of this assay was 25.2 IU/ml (95% confidence interval [CI], 19.2 to 44.1 IU/ml). The assay successfully amplified 16 different HEV sequences with significant nucleotide mismatching in primer/probe binding regions, while evaluation of a WHO international reference panel for HEV genotypes (code 8578/13) showed viral load results falling within the result ranges generated by WHO collaborative study participants for all panel members (genotypes 1 to 4). Broadly reactive RT-qPCR primers targeting HEV ORF2/3 were successfully adapted for use in an assay based on Pleiades probe chemistry. The availability of secondary standards calibrated to the WHO HEV international standard can improve the standardization and performance of assays for the detection and quantification of HEV RNA. PMID:28228493
Microscale Synthesis and Analysis of a Dipeptide.
ERIC Educational Resources Information Center
Blatchly, Richard A.; And Others
1989-01-01
Described is a microscale chemistry laboratory in which a dipeptide is synthesized from its component amino acids and analyzed using chiral-phase thin-layer chromatography. Experimental procedures, and materials are discussed. Twelve references are listed. (CW)
ERIC Educational Resources Information Center
Montes, Ingrid; Lai, Chunqiu; Sanabria, David
2003-01-01
Describes a classroom demonstration supported by the guided-inquiry experience that focuses on separation techniques and other solvent-dependent processes, such as reaction-solvent selection. (Contains 13 references.) (YDS)
Disposal of Some Problem Chemicals.
ERIC Educational Resources Information Center
Journal of Chemical Education, 1978
1978-01-01
Describes procedures for the disposal of chemicals commonly used in secondary school chemistry laboratories. Special reference is given to inorganic salts. It is suggested that cyanides and other highly toxic salts should be disposed of by experts. (MA)
ERIC Educational Resources Information Center
Barchard, Kimberly A.
2012-01-01
This article introduces new statistics for evaluating score consistency. Psychologists usually use correlations to measure the degree of linear relationship between 2 sets of scores, ignoring differences in means and standard deviations. In medicine, biology, chemistry, and physics, a more stringent criterion is often used: the extent to which…
Calcination/dissolution chemistry development Fiscal year 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delegard, C.H.
1995-09-01
The task {open_quotes}IPC Liaison and Chemistry of Thermal Reconstitution{close_quotes} is a $300,000 program that was conducted in Fiscal Year (FY) 1995 with U.S. Department of Energy (DOE) Office of Research and Development (EM-53) Efficient Separations and Processing Crosscutting Program supported under technical task plan (TTP) RL4-3-20-04. The principal investigator was Cal Delegard of the Westinghouse Hanford Company (WHC). The task encompassed the following two subtasks related to the chemistry of alkaline Hanford Site tank waste: (1) Technical Liaison with the Institute of Physical Chemistry of the Russian Academy of Science (IPC/RAS) and its research into the chemistry of transuranic elementsmore » (TRU) and technetium (Tc) in alkaline media. (2) Laboratory investigation of the chemistry of calcination/dissolution (C/D) (or thermal reconstitution) as an alternative to the present reference Hanford Site tank waste pretreatment flowsheet, Enhanced Sludge Washing (ESW). This report fulfills the milestone for the C/D subtask to {open_quotes}Provide End-of-Year Report on C/D Laboratory Test Results{close_quotes} due 30 September 1995. A companion report, fulfilling the milestone to provide an end-of-year report on the IPC/RAS liaison, also has been prepared.« less
Robinson, James C; Brown, Timothy T; Whaley, Christopher; Bozic, Kevin J
2015-09-16
Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. We obtained data on 3962 patients covered by the California Public Employees' Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, -24.9% to -9.6%) for knee procedures and by 17.0% (95% confidence interval, -29.3% to -2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy
Robinson, James C.; Brown, Timothy T.; Whaley, Christopher; Bozic, Kevin J.
2015-01-01
Background: Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. Methods: We obtained data on 3962 patients covered by the California Public Employees’ Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. Results: By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, −24.9% to −9.6%) for knee procedures and by 17.0% (95% confidence interval, −29.3% to −2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Conclusions: Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. Clinical Relevance: This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. PMID:26378263
Lawrence, Paul J.; Rogolsky, Marvin; Hanh, Vo Thi
1971-01-01
The chemistry of the binding of 14C-benzylpenicillin to sporulating cultures of Bacillus megaterium and B. subtilis is similar to that in a 4-hr vegetative culture of Staphylococcus aureus. Unlabeled penicillins prevent the binding of 14C-benzylpenicillin, but benzylpenicilloic acid and benzylpenilloic acid do not. Bound antibiotic can be removed from cells with neutral hydroxylamine at 25 C. Sporulating cultures display two intervals of enhanced binding, whereas binding to stationaryphase S. aureus cells remains constant. The first period of increased binding activity occurs during formation of the spore septum or cell wall primordium development, and the second coincides with cortex biosynthesis. PMID:4942758
NASA Astrophysics Data System (ADS)
Amaro-Rivera, Yolián; Huang, Tai-Yin; Urbina, Julio
2018-06-01
The atmospheric reference model utilized in an airglow numerical study is important since airglow emissions depend on the number density of the light-emitting species. In this study, we employ 2-dimensional, nonlinear, time-dependent numerical models, Multiple Airglow Chemistry Dynamics (MACD) and OH Chemistry Dynamics (OHCD), that use the MSISE-90, NRLMSISE-00, and Garcia and Solomon (GS) model data as atmospheric reference models, to investigate gravity wave-induced airglow variations for the OH(8,3) airglow, O2(0,1) atmospheric band, and O(1S) greenline emissions in the Mesosphere and Lower Thermosphere (MLT) region. Our results show that the OHCD-00 produces the largest wave-induced OH(8,3) airglow intensity variation (∼34%), followed by the OHCD-90 (∼30%), then by the OHCD (∼22%). For O(1S) greenline, the MACD produces the largest wave-induced variation (∼33%), followed by the MACD-90 (∼28%), then by MACD-00 (∼26%). As for O2(0,1) atmospheric band, the MACD produces the largest wave-induced variation (∼31%), followed by the MACD-90 and MACD-00 (∼29%). Our study illustrates the importance and the need for a good atmospheric reference model that can accurately represent the atmosphere.
Petersen, Per Hyltoft; Sandberg, Sverre; Fraser, Callum G
2011-04-01
The Stockholm conference held in 1999 on "Strategies to set global analytical quality specifications (AQS) in laboratory medicine" reached a consensus and advocated the ubiquitous application of a hierarchical structure of approaches to setting AQS. This approach has been widely used over the last decade, although several issues remain unanswered. A number of new suggestions have been recently proposed for setting AQS. One of these recommendations is described by Haeckel and Wosniok in this issue of Clinical Chemistry and Laboratory Medicine. Their concept is to estimate the increase in false-positive results using conventional population-based reference intervals, the delta false-positive rate due to analytical imprecision and bias, and relate the results directly to the current analytical quality attained. Thus, the actual estimates in the laboratory for imprecision and bias are compared to the AQS. These values are classified in a ranking system according to the closeness to the AQS, and this combination is the new idea of the proposal. Other new ideas have been proposed recently. We wait, with great interest, as should others, to see if these newer approaches become widely used and worthy of incorporation into the hierarchy.
In Pursuit of Professionalism in the Field of Chemistry Education in China: The Story of Zhixin Liu
NASA Astrophysics Data System (ADS)
Wei, Bing
2012-09-01
In China, science educators as a professional group were originally referred to as academic staff responsible for teaching the subject-based science teaching methods course at the related science departments at teachers' universities. In this study, a biographic method was used to approach the professional life of Zhixin Liu, who was a senior science educator at the Department of Chemistry at Beijing Normal University, to reveal how he has become a professional science educator and what influences he has brought about to the chemistry education community over the past half a century in China. The main findings of this study were the two roles played by Liu in the enterprise of chemistry education in China: as an agent to disseminate national curriculum policies and as a scholar to construct the Chinese theories of chemistry teaching. Results show that the two roles were intertwined during the whole professional life of Liu. The implications of Liu's life story for dealing with the relationships between policy and practice and between theory and practice in the field of science education are discussed.
ENVIRONMENTAL IMMUNOCHEMISTRY RESPONDING TO A SPECTRUM OF ANALYTICAL NEEDS
A review, with 13 references, is given on the field of environmental immunochemistry which brings together several specalties, including analytical chemistry, biochemistry, moluclar biology, and environmental engineering. This multidisciplinary nature is both benefit and a confus...
Teaching Relative Acidity in the Undergraduate Organic Chemistry Course.
ERIC Educational Resources Information Center
Traynham, James G.
1988-01-01
Described is a teaching method for connecting relative acidity among various species by the use of familiar references. Considered are teaching the acidity of alpha-hydrogens of ketones, alkylation of amides and imides, and others. (CW)
Chemical Analysis of Soils: An Environmental Chemistry Laboratory for Undergraduate Science Majors.
ERIC Educational Resources Information Center
Willey, Joan D.; Avery, G. Brooks, Jr.; Manock, John J.; Skrabal, Stephen A.; Stehman, Charles F.
1999-01-01
Describes a laboratory exercise for undergraduate science students in which they evaluate soil samples for various parameters related to suitability for crop production and capability for retention of contaminants. (Contains 18 references.) (WRM)
[Drugs and pharmaceutical episodes in "Sazae-San": Japanese comic strips in 1940s-1970s].
Goino, Masahiko
2009-01-01
This is a report on episodes with references to drugs and pharmaceuticals in one of the most famous Japanese comic strips, "Sazae-san", in the period from 1945 to 1974. There were 111 episodes of "Sazae-san" including references to drugs and pharmaceuticals in this period. In the period from 1945 to 1954, there were some references to pharmacists and pharmacies but only a small number of references in the period from 1965 to 1974. In the period from 1945 to 1954, there were references to disinfectants and insecticides in the hygienic chemistry field. However, in the period from 1965 to 1974, there were references to environmental problems, food additives and agricultural chemicals. As drug development has progressed, the number of references to practical drugs in "Sazae-san" has decreased over the period from 1945-1974.
NASA Technical Reports Server (NTRS)
Anicich, V. G.; Huntress, W. T., Jr.
1986-01-01
All bimolecular positive ion-molecule reactions reported from 1965 to 1985 for temperatures below 1000 K are included in the present survey of those ion-molecule reactions pertinent to the chemistries of planetary atmospheres, cometary comae, and interstellar clouds. This survey is intended as an update of the first, by Huntress (1977). The tabular presentation is organized according to reactant ion, with cross-references for both the ionic and the neutral reactants as well as the ionic and neutral products.
Gorbacheva, N A; Orlova, A M
2012-01-01
The authors discuss the system of information about investigations on toxicological (forensic) chemistry carried out for obtaining the scientific degree as it has formed in this country. They present a review and a list of theses and their abstracts in this discipline defended during the period from 1936 to 2010. The analysis of the themes of the studies is performed with reference to the dynamics of preparation of the theses in the Soviet and post-Soviet periods.
Fathead minnow genome sequencing and assembly
The dataset provides the URLs for accessing the genome sequence data and two draft assemblies as well as fathead minnow genotyping data associated with estimating the heterozygosity of the in-bred line.This dataset is associated with the following publication:Burns, F., L. Cogburn, G. Ankley , D. Villeneuve , E. Waits , Y. Chang, V. Llaca, S. Deschamps, R. Jackson, and R. Hoke. Sequencing and De novo Draft Assemblies of the Fathead Minnow (Pimphales promelas)Reference Genome. ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY. Society of Environmental Toxicology and Chemistry, Pensacola, FL, USA, 35(1): 212-217, (2016).
Hug, Bruce; Abbas, Richat; Leister, Cathie; Burns, Jaime; Sonnichsen, Daryl
2010-08-01
Neratinib is an orally administered, small-molecule, irreversible pan-ErbB inhibitor in development for the treatment of ErbB2-positive breast cancer. This study assessed the effects of therapeutic and supratherapeutic neratinib concentrations on cardiac repolarization, in accordance with current regulatory guidance. This was a two-part study in healthy subjects. In part 1, subjects were randomized to receive placebo, 400 mg moxifloxacin, or 240 mg neratinib (therapeutic dose) following a high-fat meal. In part 2, after a washout period, subjects received placebo plus 400 mg ketoconazole or 240 mg neratinib plus ketoconazole (supratherapeutic dose). ANOVA was used to compare the baseline-adjusted QTc interval for neratinib with that of placebo (reference), and for neratinib plus ketoconazole with that of placebo plus ketoconazole (reference). Pharmacokinetic/pharmacodynamic analyses and categorical summaries of interval data were done. Assay sensitivity was evaluated by the effect of moxifloxacin on QTc compared with placebo. Sixty healthy subjects were enrolled in this study. The upper bounds of the 90% confidence interval for baseline-adjusted QTcN (population-specific corrected QT) were =10 milliseconds greater than the corresponding reference at all postdose time points under conditions of both therapeutic and supratherapeutic plasma concentrations of neratinib. Pharmacokinetic/pharmacodynamic analysis revealed no relationship between neratinib concentrations and QTc interval. No subjects had QTcI, QTcF, or QTcN intervals >450 milliseconds or change from baseline >30 milliseconds. Moxifloxacin produced a significant increase in QTcN compared with placebo (P < 0.05). Therapeutic and supratherapeutic plasma concentrations of neratinib do not prolong the QTc interval in healthy subjects. (c) 2010 AACR.
Controls on dripwater chemistry of Oregon Caves National Monument, northwestern United States
NASA Astrophysics Data System (ADS)
Rushdi, Ahmed I.; Ersek, Vasile; Mix, Alan C.; Clark, Peter U.
2018-02-01
Cave dripwater chemistry of Oregon Caves National Monument (OCNM) was studied, where the parameters pH, total alkalinity, calcium, magnesium, strontium, sodium and barium were analyzed at quasi-monthly intervals from 2005 to 2007. Different statistical analyses have been used to investigate the variability of the chemical parameters in the different sites in the OCNM cave system. The dripwater varies in response to seasonal changes in rainfall. The drip rates range from zero in summer to continuous flow in winter, closely following the rainfall intensity. Spatial variations of dripwater chemistry, which is nonlinearly related to dripwater discharge likely, reflect the chemical composition of bedrock and overlying soil, and the residence time of the ground water within the aquifer. The residence time of infiltrated water in bedrock cracks control the dissolution carbonate bedrock, reprecipitation of calcium carbonate and the degree of saturation of dripwater with respect to calcium carbonate minerals. Spatiotemporal fluctuations of dripwater Mg/Ca and Sr/Ca ratios are controlled by dissolution of carbonate bedrock and the degree of calcite reprecipitation in bedrock cracks. This suggests that trace elements in speleothem deposits at the OCNM may serve as paleoclimatological proxies for precipitation, if interpreted within the context of understanding local bedrock chemistry.
Yamagata, Tetsuo; Zanelli, Ugo; Gallemann, Dieter; Perrin, Dominique; Dolgos, Hugues; Petersson, Carl
2017-09-01
1. We compared direct scaling, regression model equation and the so-called "Poulin et al." methods to scale clearance (CL) from in vitro intrinsic clearance (CL int ) measured in human hepatocytes using two sets of compounds. One reference set comprised of 20 compounds with known elimination pathways and one external evaluation set based on 17 compounds development in Merck (MS). 2. A 90% prospective confidence interval was calculated using the reference set. This interval was found relevant for the regression equation method. The three outliers identified were justified on the basis of their elimination mechanism. 3. The direct scaling method showed a systematic underestimation of clearance in both the reference and evaluation sets. The "Poulin et al." and the regression equation methods showed no obvious bias in either the reference or evaluation sets. 4. The regression model equation was slightly superior to the "Poulin et al." method in the reference set and showed a better absolute average fold error (AAFE) of value 1.3 compared to 1.6. A larger difference was observed in the evaluation set were the regression method and "Poulin et al." resulted in an AAFE of 1.7 and 2.6, respectively (removing the three compounds with known issues mentioned above). A similar pattern was observed for the correlation coefficient. Based on these data we suggest the regression equation method combined with a prospective confidence interval as the first choice for the extrapolation of human in vivo hepatic metabolic clearance from in vitro systems.
Clarifying Atomic Weights: A 2016 Four-Figure Table of Standard and Conventional Atomic Weights
ERIC Educational Resources Information Center
Coplen, Tyler B.; Meyers, Fabienne; Holden, Norman E.
2017-01-01
To indicate that atomic weights of many elements are not constants of nature, in 2009 and 2011 the Commission on Isotopic Abundances and Atomic Weights (CIAAW) of the International Union of Pure and Applied Chemistry (IUPAC) replaced single-value standard atomic weight values with atomic weight intervals for 12 elements (hydrogen, lithium, boron,…
Pretorius, Carel J; Tate, Jillian R; Wilgen, Urs; Cullen, Louise; Ungerer, Jacobus P J
2018-05-01
We investigated the analytical performance, outlier rate, carryover and reference interval of the Beckman Coulter Access hsTnI in detail and compared it with historical and other commercial assays. We compared the imprecision, detection capability, analytical sensitivity, outlier rate and carryover against two previous Access AccuTnI assay versions. We established the reference interval with stored samples from a previous study and compared the concordances and variances with the Access AccuTnI+3 as well as with two commercial assays. The Access hsTnI had excellent analytical sensitivity with the calibration slope 5.6 times steeper than the Access AccuTnI+3. The detection capability was markedly improved with the SD of the blank 0.18-0.20 ng/L, LoB 0.29-0.33 ng/L and LoD 0.58-0.69 ng/L. All the reference interval samples had a result above the LoB value. At a mean concentration of 2.83 ng/L the SD was 0.28 ng/L (CV 9.8%). Carryover (0.005%) and outlier (0.046%) rates were similar to the Access AccuTnI+3. The combined male and female 99th percentile reference interval was 18.2 ng/L (90% CI 13.2-21.1 ng/L). Concordance amongst the assays was poor with only 16.7%, 19.6% and 15.2% of samples identified by all 4 assays as above the 99th, 97.5th and 95th percentiles. Analytical imprecision was a minor contributor to the observed variances between assays. The Beckman Coulter Access hsTnI assay has excellent analytical sensitivity and precision characteristics close to zero. This allows cTnI measurement in all healthy individuals and the capability to identify numerically small differences between serial samples as statistically significant. Concordance in healthy individuals remains poor amongst assays. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.
Mendes, G D; Moreira, L D; Pereira, A dos S; Borges, A; Yui, F; Mendes, F D; de Nucci, G
2007-03-01
The aim of this study was to evaluate, in human volunteers, the performance of one gliclazide tablet formulation (gliclazide 80 mg tablet from EMS Indústria Farmacêutica Ltda.) against two reference gliclazide tablet formulations (Diamicron 80 mg tablet from Servier do Brazil Ltda. and Diamicron 80 mg tablet from Servier (Ireland) Industries Limited). The study had an open, randomized, three-period crossover design with a one-week washout interval between doses. The samples were obtained over a 48-h interval after each oral administration of gliclazide. The samples were extracted from plasma using diethylether : hexane (80 : 20, v/v) and the extracts were analyzed by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/ MS). Chromatography was performed isocratically using a Jones Chromatography Genesis C8 120A 4u. The method had a chromatographic run-time of 2.5 min and a calibration curve of the range of 0.02- 10 microg x ml(-1) (r(2) > 0.9993). The limit of quantification was 0.02 microg x ml(-1). The geometric mean and 90% confidence intervals (CI) for the Gliclazide/Diamicron (Ireland) ratio were 588.68% (90% CI= 491.16, 705.58%) for AUClast, 423.50% (90% CI = 338.25, 530.23%) for AUCinf, and 1395.77% (90% CI= 1116.62, 1744.72%) for Cmax. The geometric mean and 90% confidence intervals (CI) for the Gliclazide/Diamicron (Brazil) ratio were 249.16% (90% CI = 207.96, 298.54%) for AUCiast, 249.16% (90% CI = 207.96 - 298.54%) for AUCinf, and 188.04% (90% CI - 151.72, 233.05%) for Cmax. Since the 90% CI for Cmax, AUClast and AUC(0-infinity) ratios were all outside the 125% interval proposed by the US Food and Drug Administration, we concluded that the gliclazide test formulation were not bioequivalent to either reference formulation. Interestingly, the pharmacokinetic parameters such as Cmax, AUClast of both reference formulations are compatible with neither the literature nor the profile of an immediate release formulation. In addition, both reference formulations were not bioequivalent in themselves, indicating significant differences in reference product formulation.
Yongjin, Chen; Weihong, Li; Jiazhen, Liu; Ming, Lu; Mengchen, Xu; Shengliang, Liu
2015-08-01
Based on monitoring data collected from 2006 to 2009 at the lower reaches of the Tarim River, tempo-spatial variations in groundwater depth and chemistry during an approximately 3-year interval of intermittent water delivery were studied. Results indicate that as the groundwater depth increased at the upper sector of the river's lower reaches from March 2007 to September 2009, so too did the main chemical composition of groundwater. Groundwater depth at the intermediate sector also increased, but major ions in groundwater declined. The groundwater depth at the lower sector started to decrease in August 2008, and the concentrations of main ions in the groundwater generally rose and fell along with the variations in groundwater depth. The groundwater depth and chemistry in the monitoring wells located at a distance from the aqueduct expressed complex changes at different sections. For instance, at the section near the Daxihaizi Reservoir Section B, groundwater depth increased gradually, but chemical composition changed little. In contrast, the groundwater depth of monitoring wells far from the Daxihaizi Reservoir (Section I) decreased and salt content in the groundwater increased. In sectors at a moderate distance from the reservoir, groundwater depth decreased and concentrations of main ions significantly increased.
NASA Astrophysics Data System (ADS)
Love, Brooke A.; Olson, M. Brady; Wuori, Tristen
2017-05-01
As research into the biotic effects of ocean acidification has increased, the methods for simulating these environmental changes in the laboratory have multiplied. Here we describe the atmospheric carbon control simulator (ACCS) for the maintenance of plankton under controlled pCO2 conditions, designed for species sensitive to the physical disturbance introduced by the bubbling of cultures and for studies involving trophic interaction. The system consists of gas mixing and equilibration components coupled with large-volume atmospheric simulation chambers. These chambers allow gas exchange to counteract the changes in carbonate chemistry induced by the metabolic activity of the organisms. The system is relatively low cost, very flexible, and when used in conjunction with semi-continuous culture methods, it increases the density of organisms kept under realistic conditions, increases the allowable time interval between dilutions, and/or decreases the metabolically driven change in carbonate chemistry during these intervals. It accommodates a large number of culture vessels, which facilitate multi-trophic level studies and allow the tracking of variable responses within and across plankton populations to ocean acidification. It also includes components that increase the reliability of gas mixing systems using mass flow controllers.
ERIC Educational Resources Information Center
Nicoll, Gayle
2003-01-01
Reports research that investigates the encoding that students use to develop molecular models at the undergraduate level. Focuses on the translation between symbolic and subatomic representations of molecules. (Contains 31 references.) (DDR)
Shahbazian, M. D.; Valsamakis, A.; Boonyaratanakornkit, J.; Cook, L.; Pang, X. L.; Preiksaitis, J. K.; Schönbrunner, E. R.; Caliendo, A. M.
2013-01-01
Commutability of quantitative reference materials has proven important for reliable and accurate results in clinical chemistry. As international reference standards and commercially produced calibration material have become available to address the variability of viral load assays, the degree to which such materials are commutable and the effect of commutability on assay concordance have been questioned. To investigate this, 60 archived clinical plasma samples, which previously tested positive for cytomegalovirus (CMV), were retested by five different laboratories, each using a different quantitative CMV PCR assay. Results from each laboratory were calibrated both with lab-specific quantitative CMV standards (“lab standards”) and with common, commercially available standards (“CMV panel”). Pairwise analyses among laboratories were performed using mean results from each clinical sample, calibrated first with lab standards and then with the CMV panel. Commutability of the CMV panel was determined based on difference plots for each laboratory pair showing plotted values of standards that were within the 95% prediction intervals for the clinical specimens. Commutability was demonstrated for 6 of 10 laboratory pairs using the CMV panel. In half of these pairs, use of the CMV panel improved quantitative agreement compared to use of lab standards. Two of four laboratory pairs for which the CMV panel was noncommutable showed reduced quantitative agreement when that panel was used as a common calibrator. Commutability of calibration material varies across different quantitative PCR methods. Use of a common, commutable quantitative standard can improve agreement across different assays; use of a noncommutable calibrator can reduce agreement among laboratories. PMID:24025907
Carlisle, D.M.; Clements, W.H.
2003-01-01
Secondary production estimates from several Rocky Mountain streams were used to test hypotheses about the effects of chronic metal contamination on insect populations and ecosystem processes. Quantitative samples of chemistry, habitat, and benthic insects were collected monthly during the ice-free period (May-November) from five 2nd- to 3rd-order streams that varied primarily in Zn contamination. Secondary production was estimated for the 19 dominant taxa using increment-summation, size-frequency, and P/B methods. Uncertainty was estimated by bootstrapping estimates of mean abundance, biomass, and cohort production intervals. Secondary production of metal-sensitive Heptageniidae (Rhithrogena robusta, Cinygmula spp., and Epeorus longimanus) was lower in lightly to moderately contaminated streams than in reference streams. Experiments were done to determine whether herbivore growth was influenced by food quality in contaminated streams. Growth estimates from field and microcosm experiments revealed that low mayfly production in contaminated streams was caused mostly by reduced population abundances. Production of predatory stoneflies was also lower in contaminated streams than reference streams. Estimates of the trophic basis of production revealed that, although the relative contribution to community production from various food sources was similar among streams, total production attributable to algae and animal prey declined in contaminated streams. Much of the reduction in herbivory in contaminated streams was the result of lower production of heptageniids, especially R. robusta. Assemblage and taxon-specific estimates of secondary production were sensitive to variation in metal contamination and indicated that relatively low metal concentrations may have ecosystem-wide consequences for energy flow.
NASA Astrophysics Data System (ADS)
Haase, S.; Matthes, K. B.
2017-12-01
Changes in stratospheric ozone can trigger tropospheric circulation changes. In the Southern hemisphere (SH), the observed shift of the Southern Annular Mode was attributed to the observed trend in lower stratospheric ozone. In the Northern Hemisphere (NH), a recent study showed that extremely low stratospheric ozone conditions during spring produce robust anomalies in the troposphere (zonal wind, temperature and precipitation). This could only be reproduced in a coupled chemistry climate model indicating that chemical-dynamical feedbacks are also important on the NH. To further investigate the importance of interactive chemistry for surface climate, we conducted a set of experiments using NCAR's Community Earth System Model (CESM1) with the Whole Atmosphere Community Climate Model (WACCM) as the atmosphere component. WACCM contains a fully interactive stratospheric chemistry module in its standard configuration. It also allows for an alternative configuration, referred to as SC-WACCM, in which the chemistry (O3, NO, O, O2, CO2 and chemical and shortwave heating rates) is specified as a 2D field in the radiation code. A comparison of the interactive vs. the specified chemistry version enables us to evaluate the relative importance of interactive chemistry by systematically inhibiting the feedbacks between chemistry and dynamics. To diminish the effect of temporal interpolation when prescribing ozone, we use daily resolved zonal mean ozone fields for the specified chemistry run. Here, we investigate the differences in stratosphere-troposphere coupling between the interactive and specified chemistry simulations for the mainly chemically driven SH as well as for the mainly dynamically driven NH. We will especially consider years that are characterized by extremely low stratospheric ozone on the one hand and by large dynamical disturbances, i.e. Sudden Stratospheric Warmings, on the other hand.
Labonté, Josiane; Roy, Jean-Philippe; Dubuc, Jocelyn; Buczinski, Sébastien
2015-06-01
Cardiac troponin I (cTnI) has been shown to be an accurate predictor of myocardial injury in cattle. The point-of-care i-STAT 1 immunoassay can be used to quantify blood cTnI in cattle. However, the cTnI reference interval in whole blood of healthy early lactating dairy cows remains unknown. To determine a blood cTnI reference interval in healthy early lactating Holstein dairy cows using the analyzer i-STAT 1. Forty healthy lactating dairy Holstein cows (0-60 days in milk) were conveniently selected from four commercial dairy farms. Each selected cow was examined by a veterinarian and transthoracic echocardiography was performed. A cow-side blood cTnI dosage was measured at the same time. A bootstrap statistical analysis method using unrestricted resampling was used to determine a reference interval for blood cTnI values. Forty healthy cows were recruited in the study. Median blood cTnI was 0.02 ng/mL (minimum: 0.00, maximum: 0.05). Based on the bootstrap analysis method with 40 cases, the 95th percentile of cTnI values in healthy cows was 0.036 ng/mL (90% CI: 0.02-0.05 ng/mL). A reference interval for blood cTnI values in healthy lactating cows was determined. Further research is needed to determine whether cTnI blood values could be used to diagnose and provide a prognosis for cardiac and noncardiac diseases in lactating dairy cows. Copyright © 2015 Elsevier B.V. All rights reserved.
Edvardsson, Maria; Sund-Levander, Märtha; Milberg, Anna; Wressle, Ewa; Marcusson, Jan; Grodzinsky, Ewa
2018-02-23
Reference intervals are widely used as decision tools, providing the physician with information about whether the analyte values indicate ongoing disease process. Reference intervals are generally based on individuals without diagnosed diseases or use of medication, which often excludes elderly. The aim of the study was to assess levels of albumin, alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine and γ-glutamyl transferase (γ-GT) in frail, moderately healthy and healthy elderly indivuduals. Blood samples were collected from individuals >80 years old, nursing home residents, in the Elderly in Linköping Screening Assessment and Nordic Reference Interval Project, a total of 569 individuals. They were divided into three cohorts: frail, moderately healthy and healthy, depending on cognitive and physical function. Albumin, ALT, AST, creatinine and γ-GT were analyzed using routine methods. Linear regression predicted factors for 34% of the variance in albumin were activities of daily living (ADL), gender, stroke and cancer. ADLs, gender and weight explained 15% of changes in ALT. For AST levels, ADLs, cancer and analgesics explained 5% of changes. Kidney disease, gender, Mini Mental State Examination (MMSE) and chronic obstructive pulmonary disease explained 25% of the variation in creatinine levels and MMSE explained three per cent of γ-GT variation. Because a group of people are at the same age, they should not be assessed the same way. To interpret results of laboratory tests in elderly is a complex task, where reference intervals are one part, but far from the only one, to take into consideration.
Hyatt, Michael W; Field, Cara L; Clauss, Tonya M; Arheart, Kristopher L; Cray, Carolyn
2016-12-01
Preventative health care of elasmobranchs is an important but understudied field of aquatic veterinary medicine. Evaluation of inflammation through the acute phase response is a valuable tool in health assessments. To better assess the health of bonnethead sharks ( Sphyrna tiburo ) under managed care, normal reference intervals of protein electrophoresis (EPH) and the acute phase proteins, C-reactive protein (CRP) and haptoglobin (HP), were established. Blood was collected from wild caught, captive raised bonnethead sharks housed at public aquaria. Lithium heparinized plasma was either submitted fresh or stored at -80°C prior to submission. Electrophoresis identified protein fractions with migration characteristics similar to other animals with albumin, α-1 globulin, α-2 globulin, β globulin, and γ globulin. These fractions were classified as fractions 1-5 as fractional contents are unknown in this species. Commercial reagents for CRP and HP were validated for use in bonnethead sharks. Reference intervals were established using the robust method recommended by the American Society for Veterinary Clinical Pathology for the calculation of 90% reference intervals. Once established, the diagnostic and clinical applicability of these reference intervals was used to assess blood from individuals with known infectious diseases that resulted in systemic inflammation and eventual death. Unhealthy bonnethead sharks had significantly decreased fraction 2, fraction 3, and fraction 3:4 ratio and significantly increased fraction 5, CRP, and HP. These findings advance our understanding of elasmobranch acute phase inflammatory response and health and aid clinicians in the diagnosis of inflammatory disease in bonnethead sharks.
Boulouis, Gregoire; Siddiqui, Khawja-Ahmeruddin; Lauer, Arne; Charidimou, Andreas; Regenhardt, Robert W; Viswanathan, Anand; Leslie-Mazwi, Thabele M; Rost, Natalia; Schwamm, Lee H
2017-08-01
Current guidelines for endovascular thrombectomy (EVT) used to select patients for transfer to thrombectomy-capable stroke centers (TSC) may result in unnecessary transfers. We sought to determine the impact of simulated baseline vascular imaging on reducing unnecessary transfers and clinical-imaging factors associated with receiving EVT after transfer. We identified patients with stroke transferred for EVT from 30 referring hospitals between 2010 and 2016 who had a referring hospitals brain computed tomography and repeat imaging on TSC arrival available for review. Initial Alberta Stroke Program Early CT scores and TSC vascular occlusion level were assessed. The main outcome variable was receiving EVT at TSC. Models were simulated to derive optimal triaging parameters for EVT. A total of 508 patients were included in the analysis (mean age, 69±14 years; 42% women). Application at referring hospitals of current guidelines for EVT yielded sensitivity of 92% (95% confidence interval, 0.84-0.96) and specificity of 53% (95% confidence interval, 0.48-0.57) for receiving EVT at TSC. Repeated simulations identified optimal selection criteria for transfer as National Institute of Health Stroke Scale >8 plus baseline vascular imaging (sensitivity=91%; 95% confidence interval, 0.83-0.95; and specificity=80%; 95% confidence interval, 0.75-0.83). Our findings provide quantitative estimates of the claim that implementing vascular imaging at the referring hospitals would result in significantly fewer futile transfers for EVT and a data-driven framework to inform transfer policies. © 2017 American Heart Association, Inc.
Aerosol chemistry during the wet season in central Amazonia - The influence of long-range transport
NASA Technical Reports Server (NTRS)
Talbot, R. W.; Andreae, M. O.; Berresheim, H.; Artaxo, P.; Garstang, M.
1990-01-01
The temporal variation in the concentration and chemistry of the atmospheric aerosol over central Amazonia, Brazil, during the 1987 wet season is discussed based on ground and aircraft collected data obtained during the NASA GTE ABLE 2B expedition conducted in April/May 1987. It is found that wet-season aerosol concentrations and composition are variable in contrast to the more uniform biogenic aerosol observed during the 1985 dry season; four distinct intervals of enhanced aerosol concentration coincided with short periods (3 to 5 d) of extensive rainfall. It is hypothesized that aerosol chemistry in Amazonia during the wet season is strongly influenced by long-range transport of soil dust, marine aerosol, and possibly biomass combustion products advected into the central Basin by large-scale tropospheric circulation, producing periodic pulses of material input to local boundary layer air. The resultant wet-season aerosol regime is dynamic, in contrast to the uniformity of natural biogenic aerosols during the dry season.
Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek
2015-02-01
To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.
2010-10-21
paper assess the reversible works needed to alchemi - cally change each molecule to the benzene core reference state. To automate the alchemical...the alchemi - cal free energies or reversible works, the TI procedure split the interval from the real state of the molecule at λ ) 0 to the reference
Ideograms for Physics and Chemistry
NASA Astrophysics Data System (ADS)
García Risueño, Pablo; Syropoulos, Apostolos; Vergés, Natàlia
2016-12-01
Ideograms (symbols that represent a word or idea) have great communicative value. They refer to concepts in a simple manner, easing the understanding of related ideas. Moreover, ideograms can simplify the often cumbersome notation used in the fields of Physics and physical Chemistry. Nonetheless only a few ideograms- like and - have been defined to date. In this work we propose that the scientific community follows the example of Mathematics—as well as that of oriental languages—and bestows a more important role upon ideograms. To support this thesis we propose ideograms for essential concepts in Physics and Chemistry. They are designed to be intuitive, and their goal is to make equations easier to read and understand. Our symbols are included in a publicly available [InlineEquation not available: see fulltext.]package ( svrsymbols).
Cuesta, Luciano; Sessler, Jonathan L
2009-09-01
The coordination chemistry of porphyrins and related tetrapyrrolic ligands has traditionally centered around the ability of these systems to form pyrrole N-ligated complexes via the formation of sigma bonds, either within the N(4) core or displaced above it. In fact, such sigma-complexes are known with almost every metal cation in the periodic table. However, a growing number of pi-complexes derived from tetrapyrrolic ligands have been reported in recent years. The underlying coordination mode, while still novel in the context of "porphyrin-like" chemistry, is already being recognized for the effects it can impart over the reactivity, as well as the spectroscopic, redox, electronic, and optical properties of various oligopyrrolic macrocycles. This critical review summarizes accomplishments made in this fast-emerging field (59 references).
Chemistry of water collected from an unventilated drift, Yucca Mountain, Nevada
Marshall, B.D.; Oliver, T.A.; Peterman, Z.E.
2007-01-01
Water samples (referred to as puddle water samples) were collected from the surfaces of a conveyor belt and plastic sheeting in the unventilated portion of the Enhanced Characterization of the Repository Block (ECRB) Cross Drift in 2003 and 2005 at Yucca Mountain, Nevada. The chemistry of these puddle water samples is very different than that of pore water samples from borehole cores in the same region of the Cross Drift or than seepage water samples collected from the Exploratory Studies Facility tunnel in 2005. The origin of the puddle water is condensation on surfaces of introduced materials and its chemistry is dominated by components of the introduced materials. Large CO2 concentrations may be indicative of localized chemical conditions induced by biologic activity. ?? 2007 Materials Research Society.
Hamilton, Matthew T; Kupar, Caitlin A; Kelley, Meghan D; Finger, John W; Tuberville, Tracey D
2016-07-01
: American alligators ( Alligator mississippiensis ) are one of the most studied crocodilian species in the world, yet blood and plasma biochemistry information is limited for juvenile alligators in their northern range, where individuals may be exposed to extreme abiotic and biotic stressors. We collected blood samples over a 2-yr period from 37 juvenile alligators in May, June, and July to establish reference intervals for 22 blood and plasma analytes. We observed no effect of either sex or blood collection time on any analyte investigated. However, our results indicate a significant correlation between a calculated body condition index and aspartate aminotransferase and creatine kinase. Glucose, total protein, and potassium varied significantly between sampling sessions. In addition, glucose and potassium were highly correlated between the two point-of-care devices used, although they were significantly lower with the i-STAT 1 CG8+ cartridge than with the Vetscan VS2 Avian/Reptile Rotor. The reference intervals presented herein should provide baseline data for evaluating wild juvenile alligators in the northern portion of their range.
Association between GFR Estimated by Multiple Methods at Dialysis Commencement and Patient Survival
Wong, Muh Geot; Pollock, Carol A.; Cooper, Bruce A.; Branley, Pauline; Collins, John F.; Craig, Jonathan C.; Kesselhut, Joan; Luxton, Grant; Pilmore, Andrew; Harris, David C.
2014-01-01
Summary Background and objectives The Initiating Dialysis Early and Late study showed that planned early or late initiation of dialysis, based on the Cockcroft and Gault estimation of GFR, was associated with identical clinical outcomes. This study examined the association of all-cause mortality with estimated GFR at dialysis commencement, which was determined using multiple formulas. Design, setting, participants, & measurements Initiating Dialysis Early and Late trial participants were stratified into tertiles according to the estimated GFR measured by Cockcroft and Gault, Modification of Diet in Renal Disease, or Chronic Kidney Disease-Epidemiology Collaboration formula at dialysis commencement. Patient survival was determined using multivariable Cox proportional hazards model regression. Results Only Initiating Dialysis Early and Late trial participants who commenced on dialysis were included in this study (n=768). A total of 275 patients died during the study. After adjustment for age, sex, racial origin, body mass index, diabetes, and cardiovascular disease, no significant differences in survival were observed between estimated GFR tertiles determined by Cockcroft and Gault (lowest tertile adjusted hazard ratio, 1.11; 95% confidence interval, 0.82 to 1.49; middle tertile hazard ratio, 1.29; 95% confidence interval, 0.96 to 1.74; highest tertile reference), Modification of Diet in Renal Disease (lowest tertile hazard ratio, 0.88; 95% confidence interval, 0.63 to 1.24; middle tertile hazard ratio, 1.20; 95% confidence interval, 0.90 to 1.61; highest tertile reference), and Chronic Kidney Disease-Epidemiology Collaboration equations (lowest tertile hazard ratio, 0.93; 95% confidence interval, 0.67 to 1.27; middle tertile hazard ratio, 1.15; 95% confidence interval, 0.86 to 1.54; highest tertile reference). Conclusion Estimated GFR at dialysis commencement was not significantly associated with patient survival, regardless of the formula used. However, a clinically important association cannot be excluded, because observed confidence intervals were wide. PMID:24178976
Heavy Metals in the Environment-Historical Trends
NASA Astrophysics Data System (ADS)
Callender, E.
2003-12-01
These six metals, commonly classified as heavy metals, are a subset of a larger group of trace elements that occur in low concentration in the Earth's crust. These heavy metals were mined extensively for use in the twentieth century Industrial Society. Nriagu (1988a) estimated that between 0.5 (Cd) and 310 (Cu) million metric tons of these metals were mined and ultimately deposited in the biosphere. In many instances, the inputs of these metals from anthropogenic sources exceed the contributions from natural sources (weathering, volcanic eruptions, forest fires) by several times ( Adriano, 1986). In this chapter, heavy metals (elements having densities greater than 5) and trace elements (elements present in the lithosphere in concentrations less than 0.1%) are considered synonymous.It has been observed in the past that the rate of emission of these trace metals into the atmosphere is low due to their low volatility. However, with the advent of large-scale metal mining and smelting as well as fossil-fuel combustion in the twentieth century, the emission rate of these metals has increased dramatically. As most of these emissions are released into the atmosphere where the mammals live and breathe, we see a great increase in the occurrence of health problems such as lead (Pb) poisoning, cadmium (Cd) Itai-itai disease, chromium (Cr), and nickel (Ni) carcinogenesis.In this chapter, the author has attempted to present a synopsis of the importance of these metals in the hydrocycle, their natural and anthropogenic emissions into the environment, their prevalent geochemical form incorporated into lacustrine sediments, and their time-trend distributions in watersheds that have been impacted by urbanization, mining and smelting, and other anthropogenic activities. These time trends are reconstructed from major-minor-trace-element distributions in age-dated sediment cores, mainly from reservoirs where the mass sedimentation rates (MSRs) are orders of magnitude greater than those in natural lakes, the consequences of which tend to preserve the heavy-metal signatures and minimize the metal diagenesis (Callender, 2000). This chapter focuses mainly on the heavy metals in the terrestrial and freshwater environments whilst the environmental chemistry of trace metals in the marine environment is discussed in Volume 6, Chapter 3 of the Treatise on Geochemistry.The data presented in Table 2, Table 3, Table 4 and Table 5 are updated as much as possible, with many of the references postdate the late 1980s. Notable exceptions are riverine particulate matter chemistry ( Table 2), some references in Table 3, and references concerning the geochemical properties of the six heavy metals discussed in this chapter. There appears to be no recent publication that updates the worldwide average for riverine particulate matter trace metal chemistry ( Martin and Whitfield, 1981; Martin and Windom, 1991). This is supported by the fact that two recent references ( Li, 2000; Chester, 2000) concerning marine chemistry still refer to this 1981 publication. As for references in Table 3, there is a very limited data available concerning the pathways of heavy-metal transport to lakes. Some of the important works have been considered and reviewed in this chapter. In addition, the analytical chemistry of the sedimentary materials has changed little over the past 30 years until the advent and use of inductively coupled plasma/mass spectrometry (ICP/MS) in the late 1990s. Extensive works concerning the geochemical properties of heavy metals have been published during the past 40 years and to the author's knowledge these have survived the test of time.
Danese, Elisa; Salvagno, Gian Luca; Negrini, Davide; Brocco, Giorgio; Montagnana, Martina; Lippi, Giuseppe
2017-01-01
Although the clinical significance of measuring bile acids concentration in plasma or serum has been recognized for long in patients with hepatobiliary disease and/or bile acid malabsorption, the reference separation techniques are expensive and mostly unsuitable for early diagnosis and for measuring large volumes of samples. Therefore, this study was aimed to evaluate the analytical performance of three commercial enzymatic techniques for measuring total bile acids in plasma using a fully-automated clinical chemistry platform. Three commercial enzymatic assays (from Diazyme, Randox and Sentinel) were adapted for use on a Cobas Roche c501. We performed imprecision and linearity studies, and we compared results with those obtained using a reference liquid chromatography-mass spectrometry (LC-MS) technique on an identical set of lithium-heparin plasma samples. Total imprecision was optimal, always equal or lower than 3%. All assays had optimal linearity between 3-138 μmol/L. The comparison studies showed good correlation with LC-MS data (Spearman's correlation coefficients always >0.92), but all plasma samples values were significantly underestimated using the commercial enzymatic assays (-44% for Diazyme, -16% for Randox and -12% for Sentinel). The agreement at the 10 and 40 μmol/L diagnostic thresholds of total bile acids in plasma ranged between 86-92%. This discrepancy was found to be mainly attributable to a heterogeneous composition in terms of bile acids content of the three assay calibrators. This study suggests that the analytical performance of the three commercial enzymatic assays is excellent, thus confirming that automation of this important test by means of enzymatic assessment may be feasible, practical, reliable and supposedly cheap. Nevertheless, the underestimation of values compared to the reference LC-MS also suggests that the local definition and validation of reference ranges according to the combination between the specific enzymatic assay and the different clinical chemistry platforms may be advisable.
Gerlinsky, Carling D; Haulena, Martin; Trites, Andrew W; Rosen, David A S
2018-03-01
Decreased health may have lowered the birth and survival rates of Steller sea lions ( Eumetopias jubatus) in the Gulf of Alaska and Aleutian Islands over the past 30 yr. Reference ranges for clinical hematology and serum chemistry parameters needed to assess the health of wild sea lion populations are limited. Here, blood parameters were serially measured in 12 captive female Steller sea lions ranging in age from 3 wk to 16 yr to establish baseline values and investigate age-related changes. Whether diving activity affects hematology parameters in animals swimming in the ocean compared with animals in a traditional aquarium setting was also examined. Almost all blood parameters measured exhibited significant changes with age. Many of the age-related changes reflected developmental life history changes, including a change in diet during weaning, an improvement of diving capacity, and the maturity of the immune system. Mean corpuscular hemoglobin and mean corpuscular volume were also higher in the ocean diving group compared with the aquarium group, likely reflecting responses to increased exercise regimes. These data provide ranges of hematology and serum chemistry values needed to evaluate and compare the health and nutritional status of captive and wild Steller sea lions.
Use of precision time and time interval (PTTI)
NASA Technical Reports Server (NTRS)
Taylor, J. D.
1974-01-01
A review of range time synchronization methods are discussed as an important aspect of range operations. The overall capabilities of various missile ranges to determine precise time of day by synchronizing to available references and applying this time point to instrumentation for time interval measurements are described.
Identifying known unknowns using the US EPA's CompTox Chemistry Dashboard
Chemical features observed using high-resolution mass spectrometry can be tentatively identified using online chemical reference databases by searching molecular formulae and monoisotopic masses and then rank-ordering of the hits using appropriate relevance criteria. The most li...
WATER ANALYSIS: EMERGING CONTAMINANTS AND CURRENT ISSUES
This review covers developments in Water Analysis over the period of 2001-2002. A few significant references that appeared between January and February 2003 are also included. Previous Water Analysis reviews have been very comprehensive; however, in 2001, Analytical Chemistry c...
Glucose Measurement: Time for a Gold Standard
Hagvik, Joakim
2007-01-01
There is no internationally recognized reference method for the measurement of blood glucose. The Centers for Disease Control and Prevention (CDC) highlighted the need for standardization some years ago when a project was started. The project objectives were to (1) investigate whether there are significant differences in calibration levels among currently used glucose monitors for home use and (2) develop a reference method for glucose determination. A first study confirmed the assumption that currently used home-use monitors differ significantly and that standardization is necessary in order to minimize variability and to improve patient care. As a reference method, CDC recommended a method based on isotope dilution gas chromatography–mass spectrometry, an assay that has received support from clinical chemists worldwide. CDC initiated a preliminary study to establish the suitability of this method, but then the project came to a halt. It is hoped that CDC, with support from the industry, as well as academic and professional organizations such as the American Association for Clinical Chemistry and International Federation of Clinical Chemistry and Laboratory Medicine, will be able to finalize the project and develop the long-awaited and much needed “gold standard” for glucose measurement. PMID:19888402
Evaluating measurement uncertainty in fluid phase equilibrium calculations
NASA Astrophysics Data System (ADS)
van der Veen, Adriaan M. H.
2018-04-01
The evaluation of measurement uncertainty in accordance with the ‘Guide to the expression of uncertainty in measurement’ (GUM) has not yet become widespread in physical chemistry. With only the law of the propagation of uncertainty from the GUM, many of these uncertainty evaluations would be cumbersome, as models are often non-linear and require iterative calculations. The methods from GUM supplements 1 and 2 enable the propagation of uncertainties under most circumstances. Experimental data in physical chemistry are used, for example, to derive reference property data and support trade—all applications where measurement uncertainty plays an important role. This paper aims to outline how the methods for evaluating and propagating uncertainty can be applied to some specific cases with a wide impact: deriving reference data from vapour pressure data, a flash calculation, and the use of an equation-of-state to predict the properties of both phases in a vapour-liquid equilibrium. The three uncertainty evaluations demonstrate that the methods of GUM and its supplements are a versatile toolbox that enable us to evaluate the measurement uncertainty of physical chemical measurements, including the derivation of reference data, such as the equilibrium thermodynamical properties of fluids.
Harr, K.E.; Harvey, J.W.; Bonde, R.K.; Murphy, D.; Lowe, Mark; Menchaca, M.; Haubold, E.M.; Francis-Floyd, R.
2006-01-01
Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as “cold stress syndrome” and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha1 acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10–50 μg/ml with an equivocal interval of 51–70 μg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7–1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4–2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100–400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.
Harr, Kendal; Harvey, John; Bonde, Robert; Murphy, David; Lowe, Mark; Menchaca, Maya; Haubold, Elsa; Francis-Floyd, Ruth
2006-06-01
Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as "cold stress syndrome" and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha, acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10-50 microg/ml with an equivocal interval of 51-70 microg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7-1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4-2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100-400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.
Reference Determinant Dependence of the Random Phase Approximation in 3d Transition Metal Chemistry.
Bates, J E; Mezei, P D; Csonka, G I; Sun, J; Ruzsinszky, A
2017-01-10
Without extensive fitting, accurate prediction of transition metal chemistry is a challenge for semilocal and hybrid density funcitonals. The Random Phase Approximation (RPA) has been shown to yield superior results to semilocal functionals for main group thermochemistry, but much less is known about its performance for transition metals. We have therefore analyzed the behavior of reaction energies, barrier heights, and ligand dissociation energies obtained with RPA and compare our results to several semilocal and hybrid functionals. Particular attention is paid to the reference determinant dependence of RPA. We find that typically the results do not vary much between semilocal or hybrid functionals as a reference, as long as the fraction of exact exchange (EXX) mixing in the hybrid functional is small. For large fractions of EXX mixing, however, the Hartree-Fock-like nature of the determinant can severely degrade the performance. Overall, RPA systematically reduces the errors of semilocal functionals and delivers excellent performance from a single reference determinant for inherently multireference reactions. The behavior of dual hybrids that combine RPA correlation with a hybrid exchange energy was also explored, but ultimately did not lead to a systematic improvement compared to traditional RPA for these systems. We rationalize this conclusion by decomposing the contributions to the reaction energies, and briefly discuss the possible implications for double-hybrid functionals based on RPA. The correlation between EXX mixing and spin-symmetry breaking is also discussed.
Muñoz-Barús, José I; Rodríguez-Calvo, María Sol; Suárez-Peñaranda, José M; Vieira, Duarte N; Cadarso-Suárez, Carmen; Febrero-Bande, Manuel
2010-01-30
In legal medicine the correct determination of the time of death is of utmost importance. Recent advances in estimating post-mortem interval (PMI) have made use of vitreous humour chemistry in conjunction with Linear Regression, but the results are questionable. In this paper we present PMICALC, an R code-based freeware package which estimates PMI in cadavers of recent death by measuring the concentrations of potassium ([K+]), hypoxanthine ([Hx]) and urea ([U]) in the vitreous humor using two different regression models: Additive Models (AM) and Support Vector Machine (SVM), which offer more flexibility than the previously used Linear Regression. The results from both models are better than those published to date and can give numerical expression of PMI with confidence intervals and graphic support within 20 min. The program also takes into account the cause of death. 2009 Elsevier Ireland Ltd. All rights reserved.
Long-lasting ovulation inhibition with a new injectable progestagen ORG-2154.
Coutinho, E M; De Souza, J C; Barbosa, I C; Dourado Silva, V
1982-06-01
A new long-acting injectable progestagen was tested in 15 women who volunteered for the study. The occurrence of ovulation was assumed by the elevation of progesterone levels above 2ng/ml following a pre-ovulatory estradiol peak. Following a 200mg injection, ovulation was inhibited in all 15 women for five to ten months. In four subjects the interval between the injection and the first progesterone peak was five months. For eight, the interval was six to eight months. In the other three women, ovulation occurred more than eight months following injection. Bleeding episodes, similar to menstruation, occurred in most patients. Bleeding intervals lasting longer than 45 days occurred in nine subjects but more prolonged amenorrhea lasting longer than 60 days was reported by only five subjects. Blood chemistry which included blood cell counts, cholesterol, glucose, alkaline phosphatase, transaminases, urea nitrogen and creatinine remained within normal limits throughout the treatment.
Spatial Updating According to a Fixed Reference Direction of a Briefly Viewed Layout
ERIC Educational Resources Information Center
Zhang, Hui; Mou, Weimin; McNamara, Timothy P.
2011-01-01
Three experiments examined the role of reference directions in spatial updating. Participants briefly viewed an array of five objects. A non-egocentric reference direction was primed by placing a stick under two objects in the array at the time of learning. After a short interval, participants detected which object had been moved at a novel view…
2013-01-01
Background Despite the importance of abnormalities in lipoprotein metabolism in clinical canine medicine, the fact that most previously used methods for lipoprotein profiling are rather laborious and time-consuming has been a major obstacle to the wide clinical application and use of lipoprotein profiling in this species. The aim of the present study was to assess the feasibility of a continuous lipoprotein density profile (CLPDP) generated within a bismuth sodium ethylenediaminetetraacetic acid (NaBiEDTA) density gradient to characterize and compare the lipoprotein profiles of healthy dogs of various breeds, healthy Miniature Schnauzers, and Miniature Schnauzers with primary hypertriacylglycerolemia. A total of 35 healthy dogs of various breeds with serum triacylglycerol (TAG) and cholesterol concentrations within their respective reference intervals were selected for use as a reference population. Thirty-one Miniature Schnauzers with serum TAG and cholesterol concentrations within their respective reference intervals and 31 Miniature Schnauzers with hypertriacylglyceridemia were also included in the study. Results The results suggest that CLPDP using NaBiEDTA provides unique diagnostic information in addition to measurements of serum TAG and cholesterol concentrations and that it is a useful screening method for dogs with suspected lipoprotein metabolism disorders. Using the detailed and continuous density distribution information provided by the CLPDP, important differences in lipoprotein profiles can be detected even among dogs that have serum TAG and cholesterol concentrations within the reference interval. Miniature Schnauzers with serum TAG and cholesterol concentrations within the reference interval had significantly different lipoprotein profiles than dogs of various other breeds. In addition, it was further established that specific lipoprotein fractions are associated with hypertriacylglyceridemia in Miniature Schnauzers. Conclusions The results of the present study suggest that density gradient ultracentrifugation using NaBiEDTA is a useful screening method for the study of lipoprotein profiles in dogs. Therefore, this method could potentially be used for diagnostic purposes for the separation of dogs suspected of having lipoprotein abnormalities from healthy dogs. PMID:23497598
Bioorganic Chemistry: Peptides and Proteins (edited by Sidney M. Hecht)
NASA Astrophysics Data System (ADS)
Anthony-Cahill, Spencer
1999-07-01
Sidney M. Hecht, Ed. Oxford University Press: New York, 1998. 532 pp. ISBN 0-19-508468-3. $75.00. The second volume in the Bioorganic Chemistry series edited by Sidney Hecht is an outstanding addition to the collections of all scientists who teach and/or do research in the field of protein chemistry. The coverage of current research is up to date and thus the book is of great relevance to all chemists with interest in proteins, not just to academicians. As an instructor I found numerous references to current research, which I have included in my lecture notes for the undergraduate Biochemistry course and a senior-level Protein Engineering course taught at WWU. In addition to the chapters covering a broad spectrum of protein chemistry, there are two chapters (protein structural analysis, site-directed mutagenesis) which are excellent introductions to laboratory procedures in protein chemistry and molecular biology. The first chapter is an overview of basic protein biochemistry and serves as an introduction to the rest of the book. This chapter is dispensable for readers familiar with introductory biochemistry. The chapter on chemical synthesis of peptides is an exhaustive review of solution and solid-phase methods, with numerous references. I was struck by the abundance of figures showing structures of reactants but the general lack of organic chemical mechanisms. This is true for the rest of the book as well. Presumably the chemistry is known to the intended reader (grad students, advanced undergrads); however, as a devoted pusher of electrons, I was expecting to see more mechanisms in this and subsequent chapters. Instructors will have to present this aspect of the chemistry in lecture. The relevance of peptide chemistry is underscored by accompanying chapters on peptide hormones and peptidomimetics. Taken together these three chapters provide an excellent introduction to pharmaceutical peptide chemistry. The chapter on total synthesis of proteins is one of my favorites. It outlines elegant synthetic approaches to the formidable problem of generating long peptides and is very readable. Complementing the chemical synthetic strategies is a chapter on recombinant methods for protein synthesis. Again, I found this to be an excellent review of methods that have become the sine qua non of protein structure-function studies. The application of site-directed mutagenesis to support protein biophysical studies is illustrated with relevant examples from the author's laboratory. The chapter Structural Analysis of Proteins is an informative review of lab procedures for analyzing primary sequence and posttranslational modifications. It might well serve as a lab manual, as in many cases recipes for a particular procedure are given in the text. At 70 pages the chapter on protein structure is the longest in the book. It is impressive in its level of detail while maintaining readability. This chapter not only provides an excellent introduction to protein structure in general but also highlights the interplay between computational methods (modeling, refinement) and classification of structural motifs that supports structure prediction. Four chapters further illustrate the diversity of research in the protein field. These topics include antibody catalysis, DNA-binding proteins that require zinc, the use of enzymes in organic synthesis, and protein-based materials research. Finally, two chapters deserve special mention as outstanding treatments of important theoretical concepts. The chapters on protein folding and proton transfer to and from carbon by enzymes stand out in my mind as excellent qualitative introductions to complex topics. Both are succinct, lucid presentations of the relevant theoretical considerations, with ample references to the primary literature for those seeking more quantitative development of the topics. This is an outstanding collection of reviews. If you are a peptide or protein chemist or a reader with a general interest in proteins, you will benefit from reading all or most of this book. Each chapter stands on its own, so the order of coverage during an academic term depends on the preference of the instructor. I have only minor suggestions for improvement. I found roughly a dozen typos in the figures and in the text. I prefer references at the end of each chapter rather than all together at the back of the book. The book would be enhanced by the inclusion of mechanisms for many of the cited reactions. Cofactor chemistry, metabolic pathway elucidation (xenobiotic biosynthesis), and enzyme mimics (other than antibodies) are not covered in this volume. It is debatable whether they should be. In the final analysis the editor had to make choices about what to include and he made very good ones. Perhaps some of the elegant synthetic chemistry being developed to elucidate biosynthetic pathways and enzyme mechanisms will appear in subsequent volumes. In my mind that is classical bioorganic chemistry and worthy of inclusion. In the meantime, Professor Hecht is to be congratulated for assembling yet another fine edition of readable and relevant Bioorganic Chemistry.
ERIC Educational Resources Information Center
Wai, C. M.; Hutchinson, S. G.
1989-01-01
Discusses the calculation of free energy in reactions between silicon dioxide and carbon. Describes several computer programs for calculating the free energy minimization and their uses in chemistry classrooms. Lists 16 references. (YP)
ENVIRONMENTAL MASS SPECTROMETRY: EMERGING CONTAMINANTS AND CURRENT ISSUES, 2006
This biennial review covers developments in Environmental Mass Spectrometry over the period of 2004-2005. A few significant references that appeared between January and February 2006 are also included. Analytical Chemistry's current policy is to limit reviews to include 100-200 s...
WATER ANALYSIS: EMERGING CONTAMINANTS AND CURRENT ISSUES, 2005 REVIEW
This biennial review covers developments in Water Analysis over the period of 2003-2004. A few significant references that appeared between January and February 2005 are also included. Analytical Chemistry's current policy is to limit reviews to include 100-200 significant refe...
WATER ANALYSIS: EMERGING CONTAMINANTS AND CURRENT ISSUES: 2007 REVIEW
This biennial review covers developments in Water Analysis over the period of 2005-2006. A few significant references that appeared between January and March 2007 are also included. Analytical Chemistry's current policy is to limit reviews to include 200-250 significant referen...
Computerized Drug Information Services
ERIC Educational Resources Information Center
And Others; Smith, Daniel R.
1972-01-01
To compare computerized services in chemistry, pharmacology, toxicology, and clinical medicine of pharmaceutical interest, equivalent profiles were run on magnetic tape files of CA-Condensates," CBAC," Excerpta Medica," MEDLARS" and Ringdoc." The results are tabulated for overlap of services, relative speed of citing references, and unique…
Models as Feedback: Developing Representational Competence in Chemistry
ERIC Educational Resources Information Center
Padalkar, Shamin; Hegarty, Mary
2015-01-01
Spatial information in science is often expressed through representations such as diagrams and models. Learning the strengths and limitations of these representations and how to relate them are important aspects of developing scientific understanding, referred to as "representational competence." Diagram translation is particularly…
Molecular genetics of secondary chemistry in Metarhizium fungi
USDA-ARS?s Scientific Manuscript database
As with many microbes, entomopathogenic fungi from the genus Metarhizium produce a plethora of small molecule metabolites, often referred to as secondary metabolites. Although these intriguing compounds are a conspicuous feature of the biology of the producing fungi, their roles in pathogenicity and...
Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Qiu, Ling; Erasmus, Rajiv; Borai, Anwar; Evgina, Svetlana; Ashavaid, Tester; Khan, Dilshad; Schreier, Laura; Rolle, Reynan; Shimizu, Yoshihisa; Kimura, Shogo; Kawano, Reo; Armbruster, David; Mori, Kazuo; Yadav, Binod K
2017-04-01
The IFCC Committee on Reference Intervals and Decision Limits coordinated a global multicenter study on reference values (RVs) to explore rational and harmonizable procedures for derivation of reference intervals (RIs) and investigate the feasibility of sharing RIs through evaluation of sources of variation of RVs on a global scale. For the common protocol, rather lenient criteria for reference individuals were adopted to facilitate harmonized recruitment with planned use of the latent abnormal values exclusion (LAVE) method. As of July 2015, 12 countries had completed their study with total recruitment of 13,386 healthy adults. 25 analytes were measured chemically and 25 immunologically. A serum panel with assigned values was measured by all laboratories. RIs were derived by parametric and nonparametric methods. The effect of LAVE methods is prominent in analytes which reflect nutritional status, inflammation and muscular exertion, indicating that inappropriate results are frequent in any country. The validity of the parametric method was confirmed by the presence of analyte-specific distribution patterns and successful Gaussian transformation using the modified Box-Cox formula in all countries. After successful alignment of RVs based on the panel test results, nearly half the analytes showed variable degrees of between-country differences. This finding, however, requires confirmation after adjusting for BMI and other sources of variation. The results are reported in the second part of this paper. The collaborative study enabled us to evaluate rational methods for deriving RIs and comparing the RVs based on real-world datasets obtained in a harmonized manner. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Kubota, K; Kadomura, T; Ohta, K; Koyama, K; Okuda, H; Kobayashi, M; Ishii, C; Fujiwara, Y; Nishiora, T; Ohmae, Y; Ohmae, T; Kitajima, M
2012-04-01
Protein-energy malnutrition is a common disorder in the elderly. Although serum albumin is commonly used as a nutritional marker, data is lacking on serum albumin levels in the elderly. The purpose of this study was to determine whether serum albumin levels decrease with advancing age and to establish reference value and interval of laboratory data for elderly people (75 years and over). Blood samples from 13821 healthy people, 42064 outpatients, and 15959 inpatients were collected during 2008. Blood from 127 of our nutrition support team (NST) patients was also collected during August 2006 and May 2009, and analyzed. Serum albumin, hemoglobin, total cholesterol levels and lymphocyte count were determined. We analyzed the change in each parameter in accordance with age, compared the data for elderly people with younger people, and established new reference values. Clinical outcomes were examined depending on the improved reference values. Albumin was lower in older persons than in younger persons. The estimated reference value and interval were 42 (48-36) g/l in older persons and was much lower in NST patients. Hemoglobin was decreased while cholesterol and lymphocyte count were not changed in older persons: all were markedly decreased in NST patients. Terms of hospital stay were significantly longer and mortality rates were significantly higher in older persons, comparing from above to below using a new reference value of albumin (36 g/l). The serum albumin level decreases with advancing age, but it was maintained to some extent in healthy older people. Serum albumin levels related to the clinical outcome. Hemoglobin and cholesterol levels and lymphocyte count were all lower in NST patients. These measurements may be valuable markers of nutritional status and can help in guiding the need for nutritional support.
Optimized angiotensin-converting enzyme activity assay for the accurate diagnosis of sarcoidosis.
Csongrádi, Alexandra; Enyedi, Attila; Takács, István; Végh, Tamás; Mányiné, Ivetta S; Pólik, Zsófia; Altorjay, István Tibor; Balla, József; Balla, György; Édes, István; Kappelmayer, János; Tóth, Attila; Papp, Zoltán; Fagyas, Miklós
2018-06-27
Serum angiotensin-converting enzyme (ACE) activity determination can aid the early diagnosis of sarcoidosis. We aimed to optimize a fluorescent kinetic assay for ACE activity by screening the confounding effects of endogenous ACE inhibitors and interfering factors. Genotype-dependent and genotype-independent reference values of ACE activity were established, and their diagnostic accuracies were validated in a clinical study. Internally quenched fluorescent substrate, Abz-FRK(Dnp)P-OH was used for ACE-activity measurements. A total of 201 healthy individuals and 59 presumably sarcoidotic patients were enrolled into this study. ACE activity and insertion/deletion (I/D) genotype of the ACE gene were determined. Here we report that serum samples should be diluted at least 35-fold to eliminate the endogenous inhibitor effect of albumin. No significant interferences were detected: up to a triglyceride concentration of 16 mM, a hemoglobin concentration of 0.71 g/L and a bilirubin concentration of 150 μM. Genotype-dependent reference intervals were considered as 3.76-11.25 U/L, 5.22-11.59 U/L, 7.19-14.84 U/L for II, ID and DD genotypes, respectively. I/D genotype-independent reference interval was established as 4.85-13.79 U/L. An ACE activity value was considered positive for sarcoidosis when it exceeded the upper limit of the reference interval. The optimized assay with genotype-dependent reference ranges resulted in 42.5% sensitivity, 100% specificity, 100% positive predictive value and 32.4% negative predictive value in the clinical study, whereas the genotype-independent reference range proved to have inferior diagnostic efficiency. An optimized fluorescent kinetic assay of serum ACE activity combined with ACE I/D genotype determination is an alternative to invasive biopsy for confirming the diagnosis of sarcoidosis in a significant percentage of patients.
Wang, X.; Burns, Douglas A.; Yanai, R.D.; Briggs, R.D.; Germain, R.H.
2006-01-01
Clearcut forest harvesting typically results in large changes in stream water chemistry in northeastern North America. The effects of partial forest harvests on stream chemistry have not received as much attention, even though partial cutting is a more common forestry practice than clearcutting in this region. Changes in stream water chemistry following a partial cut are reported here from a 10 ha study catchment in a northern hardwood forest in the Catskill Mountains of southern New York, and are compared to those of a nearby 48 ha reference catchment. The lower two thirds of the treatment catchment was harvested in February-April 2002 by a shelterwood method, such that 33% of the basal area of the catchment was removed. Stream NO3-, NH4+, Ca2+, K+, and total dissolved aluminum (Alto) concentrations increased significantly after the harvest. Stream Ca2+, Mg2+ and NH4+ concentrations peaked 5 months after the initiation of the harvest, NO 3- and K+ concentrations peaked 6 months after cutting, and Alto concentrations peaked 1 year after cutting. Streamflow was not significantly affected by the harvest when compared to the flow of three nearby streams. Export of NO3- in stream water increased five-fold the year after the cut, and briefly exceeded atmospheric inputs of inorganic nitrogen during 4 months in the fall of 2002. Changes in stream NO3- and K+ concentrations were less than predicted by the relative basal area removed compared with those of a recent nearby clearcut. In contrast, changes in Ca2+, Mg 2+ and Alto concentrations were approximately proportional to basal area removal in these two cuts. Stream chemistry returned to values close to those of the pre-cut period and to reference values by early spring of 2003, just over a year after the initiation of the harvest, except for NO 3- concentrations, which remained elevated above background 18-20 months after completion of the cut.
Chemistry of grapes and other fruits as the raw materials involved in winemaking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallander, J.F.
The chemical composition of raw fruits is significant in winemaking and wine quality. The chemistry of grapes is particularly important to winemaking, but the composition of other fruits such as apples, pears, cherries, and blackberries is also discussed. Sugars in fruits and their importance in winemaking are discussed. Since wine acidity is essential to biological stability and tartness, information concerning organic acids is presented for several fruits. The occurrence and significance to winemaking of other essential constituents of fruits such as vitamins, enzymes, pectins, minerals, aromatic volatiles, and nitrogenous and phenolic substances are also discussed. 277 references.
A glossary of corrosion-related terms used in science and industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vukasovich, M.S.
1995-12-31
A Glossary of Corrosion-Related Terms Used in Science and Industry features definitions for over 4,000 specialized terms related to corrosion and corrosion prevention/control. Its coverage encompasses not only the fundamental terms commonly used in corrosion science, but also lesser-known, industry-specific jargon. The Glossary contains terms relevant to the study, effect, and control of corrosion that pertain to chemistry/electro-chemistry, metallurgy, plastics, paints/coatings, metal finishing, and the environment. Various synonyms, acronyms, and abbreviations are also included. A practical desk reference for students, scientists, engineers, technicians, and manufacturing and maintenance personnel.
NASA Technical Reports Server (NTRS)
Anicich, V. G.
1993-01-01
This is a supplement to a previous paper (Anicich & Huntress 1986). It is a survey of bimolecular positive ion-molecule reactions with potential importance to the chemistry of planetary atmospheres, cometary comae, and interstellar clouds. This supplement covers the literature from 1986 through 1991, with some additional citations missed in the original survey. Over 200 new citations are included. A table of reactions is listed by reactant ion, and cross-references are provided for both ionic and neutral reactants and also for both ionic and neutral products.
NASA Astrophysics Data System (ADS)
Mykhalichko, B. M.; Temkin, Oleg N.; Mys'kiv, M. G.
2000-11-01
Characteristic features of the coordination chemistry of Cu(I) and mechanisms of catalytic conversions of alkynes in the CuCl-MCl-H2O-HC≡CR system (MCl is alkali metal or ammonium chloride or amine hydrochloride; R=H, CH2OH, CH=CH2, etc.) are analysed based on studies of the compositions and structures of copper(I) chloride (bromide) complexes, alkyne π-complexes and ethynyl organometallic polynuclear compounds formed in this system in solutions and in the crystalline state. The role of polynuclear complexes in various reactions of alkynes is discussed. The bibliography includes 149 references.
Mass spectrometry. [review of techniques
NASA Technical Reports Server (NTRS)
Burlingame, A. L.; Kimble, B. J.; Derrick, P. J.
1976-01-01
Advances in mass spectrometry (MS) and its applications over the past decade are reviewed in depth, with annotated literature references. New instrumentation and techniques surveyed include: modulated-beam MS, chromatographic MS on-line computer techniques, digital computer-compatible quadrupole MS, selected ion monitoring (mass fragmentography), and computer-aided management of MS data and interpretation. Areas of application surveyed include: organic MS and electron impact MS, field ionization kinetics, appearance potentials, translational energy release, studies of metastable species, photoionization, calculations of molecular orbitals, chemical kinetics, field desorption MS, high pressure MS, ion cyclotron resonance, biochemistry, medical/clinical chemistry, pharmacology, and environmental chemistry and pollution studies.
Disk Chemistry and Cometary Composition
NASA Astrophysics Data System (ADS)
Markwick, A. J.; Charnley, S. B.
2003-05-01
We will describe current chemical modelling of disks similar to the protosolar nebula. Calculations are being undertaken to determine the spatial and temporal chemistry of the gas and dust within the 5-40AU comet-forming region of the nebula. These theoretical studies aim to determine the contribution of pristine and partially-processed interstellar material from the cool outer nebula, as compared to that obtained from outward radial mixing of matter from the hot inner nebula. Reference Molecular distributions in the inner regions of protostellar disks, Markwick, A. J., Ilgner, M., Millar, T. J., Henning, Th. (2002), Astron. Astrophys., 385, 632.
Disk Chemistry and Cometary Composition
NASA Astrophysics Data System (ADS)
Markwick, A. J.; Charnley, S. B.
2005-01-01
We will describe current chemical modelling of disks similar to the protosolar nebula. Calculations are being undertaken to determine the spatial and temporal chemistry of the gas and dust within the 5-40AU comet-forming region of the nebula. These theoretical studies aim to determine the contribution of pristine and partially-processed interstellar material from the cool outer nebula as compared to that obtained from outward radial mixing of matter from the hot inner nebula. Reference Molecular distributions in the inner regions of protostellar disks Markwick A. J. Ilgner M. Millar T. J. Henning Th. (2002) Astron. Astrophys. 385 632
Plasma chemistry reference values in hybrid falcons in relation to their species of origin.
Lierz, M; Hafez, H M
2006-07-15
Twenty-one blood chemistry parameters were determined in 127 peregrine falcons (Falco peregrinus), 79 gyr-peregrine hybrids and 166 gyr-saker hybrids. These parameters, together with those previously established in 53 gyr falcons (Falco rusticolus) and 234 saker falcons (Falco cherrug), were compared. There were statistically significant differences in 15 of the parameters between the saker and peregrine falcons; the saker and gyr falcons; the saker and gyr-saker hybrids; the peregrine and gyr falcons; and the peregrine and gyr-peregrine hybrids, but not between the gyr falcons and the gyr-saker falcon hybrids.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dittrich, Timothy M.; Richmann, Michael K.; Reed, Donald T.
2015-10-30
The degree of conservatism in the estimated sorption partition coefficients (K ds) used in a performance assessment model is being evaluated based on a complementary batch and column method. The main focus of this work is to investigate the role of ionic strength, solution chemistry, and oxidation state (III-VI) in actinide sorption to dolomite rock. Based on redox conditions and solution chemistry expected at the WIPP, possible actinide species include Pu(III), Pu(IV), U(IV), U(VI), Np(IV), Np(V), Am(III), and Th(IV).
Genus Caulophyllum: An Overview of Chemistry and Bioactivity
Xia, Yong-Gang; Li, Guo-Yu; Liang, Jun; Yang, Bing-You; Lü, Shao-Wa; Kuang, Hai-Xue
2014-01-01
Recently, some promising advances have been achieved in understanding the chemistry, pharmacology, and action mechanisms of constituents from genus Caulophyllum. Despite this, there is to date no systematic review of those of genus Caulophyllum. This review covers naturally occurring alkaloids and saponins and those resulting from synthetic novel taspine derivatives. The paper further discussed several aspects of this genus, including pharmacological properties, mechanisms of action, pharmacokinetics, and cell membrane chromatography for activity screening. The aim of this paper is to provide a point of reference for pharmaceutical researchers to develop new drugs from constituents of Caulophyllum plants. PMID:24876877
Genus caulophyllum: an overview of chemistry and bioactivity.
Xia, Yong-Gang; Li, Guo-Yu; Liang, Jun; Yang, Bing-You; Lü, Shao-Wa; Kuang, Hai-Xue
2014-01-01
Recently, some promising advances have been achieved in understanding the chemistry, pharmacology, and action mechanisms of constituents from genus Caulophyllum. Despite this, there is to date no systematic review of those of genus Caulophyllum. This review covers naturally occurring alkaloids and saponins and those resulting from synthetic novel taspine derivatives. The paper further discussed several aspects of this genus, including pharmacological properties, mechanisms of action, pharmacokinetics, and cell membrane chromatography for activity screening. The aim of this paper is to provide a point of reference for pharmaceutical researchers to develop new drugs from constituents of Caulophyllum plants.
Resonance Fluorescence of a Two-Level Atom Near a Metal Surface. II. Case of a Strong Driving Field,
1984-02-01
XYH thanks Prof. M. G. Raymer for a useful discussion. REFERENCES 1. X. Y. Huang, J. Lin and T. F. George, J. Chem. Phys., 80, 893 (1984). 2. X. Y...Mollow, Phys. Rev. A, 15, 1023 (1977). 12. J. L. Carlsten, A. Sz6ke and M. G. Raymer , Phys. Rev. A, 15, 1029 (1977). 13. H. Kuhn, J. Chem. Phys. 53, 101...Evanston, Illinois 60201 Austin, Texas 78712 Dr. Robert M. Hexter Dr. R. P. Van Duyne Department of Chemistry Chemistry Department University of Minnesota
IBM system/360 assembly language interval arithmetic software
NASA Technical Reports Server (NTRS)
Phillips, E. J.
1972-01-01
Computer software designed to perform interval arithmetic is described. An interval is defined as the set of all real numbers between two given numbers including or excluding one or both endpoints. Interval arithmetic consists of the various elementary arithmetic operations defined on the set of all intervals, such as interval addition, subtraction, union, etc. One of the main applications of interval arithmetic is in the area of error analysis of computer calculations. For example, it has been used sucessfully to compute bounds on sounding errors in the solution of linear algebraic systems, error bounds in numerical solutions of ordinary differential equations, as well as integral equations and boundary value problems. The described software enables users to implement algorithms of the type described in references efficiently on the IBM 360 system.
Generating method-specific Reference Ranges - A harmonious outcome?
Lee, Graham R; Griffin, Alison; Halton, Kieran; Fitzgibbon, Maria C
2017-12-01
When laboratory Reference Ranges (RR) do not reflect analytical methodology, result interpretation can cause misclassification of patients and inappropriate management. This can be mitigated by determining and implementing method-specific RRs, which was the main objective of this study. Serum was obtained from healthy volunteers (Male + Female, n > 120) attending hospital health-check sessions during June and July 2011. Pseudo-anonymised aliquots were stored (at - 70 °C) prior t° analysis on Abbott ARCHITECT c16000 chemistry and i 2000SR immunoassay analysers. Data were stratified by gender where appropriate. Outliers were excluded statistically (Tukey method) to generate non-parametric RRs (2.5th + 97.5th percentiles). RRs were compared to those quoted by Abbott and UK Pathology Harmony (PH) where possible. For 7 selected tests, RRs were verified using a data mining approach. For chemistry tests (n = 23), Upper or Lower Reference Limits (LRL or URL) were > 20% different from Abbott ranges in 25% of tests (11% from PH ranges) but in 38% for immunoassay tests (n = 13). RRs (mmol/L) for sodium (138-144), potassium (3.8-4.9) and chloride (102-110) were considerably narrower than PH ranges (133-146, 3.5-5.0 and 95-108, respectively). The gender difference for ferritin (M: 29-441, F: 8-193 ng/mL) was more pronounced than reported by Abbott (M: 22-275, F: 5-204 ng/mL). Verification studies showed good agreement for chemistry tests (mean [SD] difference = 0.4% [1.2%]) but less so for immunoassay tests (27% [29%]), particularly for TSH (LRL). Where resource permits, we advocate using method-specific RRs in preference to other sources, particularly where method bias and lack of standardisation limits RR transferability and harmonisation.
Reassessment of the Access Testosterone chemiluminescence assay and comparison with LC-MS method.
Dittadi, Ruggero; Matteucci, Mara; Meneghetti, Elisa; Ndreu, Rudina
2018-03-01
To reassess the imprecision and Limit of Quantitation, to evaluate the cross-reaction with dehydroepiandrosterone-sulfate (DHEAS), the accuracy toward liquid chromatography-mass spectrometry (LC-MS) and the reference interval of the Access Testosterone method, performed by DxI immunoassay platform (Beckman Coulter). Imprecision was evaluated testing six pool samples assayed in 20 different run using two reagents lots. The cross-reaction with DHEAS was studied both by a displacement curve and by spiking DHEAS standard in two serum samples with known amount of testosterone. The comparison with LC-MS was evaluated by Passing-Bablock analysis in 21 routine serum samples and 19 control samples from an External Quality Assurance (EQA) scheme. The reference interval was verified by an indirect estimation on 2445 male and 2838 female outpatients. The imprecision study showed a coefficient of variation (CV) between 2.7% and 34.7% for serum pools from 16.3 and 0.27 nmol/L. The value of Limit of Quantitation at 20% CV was 0.53 nmol/L. The DHEAS showed a cross-reaction of 0.0074%. A comparison with LC-MS showed a trend toward a slight underestimation of immunoassay vs LC-MS (Passing-Bablock equations: DxI=-0.24+0.906 LCMS in serum samples and DxI=-0.299+0.981 LCMS in EQA samples). The verification of reference interval showed a 2.5th-97.5th percentile distribution of 6.6-24.3 nmol/L for male over 14 years and <0.5-2.78 nmol/L for female subjects, in accord with the reference intervals reported by the manufacturer. The Access Testosterone method could be considered an adequately reliable tool for the testosterone measurement. © 2017 Wiley Periodicals, Inc.
Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui
2017-11-01
To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (P<.001). The median obtained were (normal vs pregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.
Development of Salivary Cortisol Circadian Rhythm and Reference Intervals in Full-Term Infants.
Ivars, Katrin; Nelson, Nina; Theodorsson, Annette; Theodorsson, Elvar; Ström, Jakob O; Mörelius, Evalotte
2015-01-01
Cortisol concentrations in plasma display a circadian rhythm in adults and children older than one year. Earlier studies report divergent results regarding when cortisol circadian rhythm is established. The present study aims to investigate at what age infants develop a circadian rhythm, as well as the possible influences of behavioral regularity and daily life trauma on when the rhythm is established. Furthermore, we determine age-related reference intervals for cortisol concentrations in saliva during the first year of life. 130 healthy full-term infants were included in a prospective, longitudinal study with saliva sampling on two consecutive days, in the morning (07:30-09:30), noon (10:00-12:00) and evening (19:30-21:30), each month from birth until the infant was twelve months old. Information about development of behavioral regularity and potential exposure to trauma was obtained from the parents through the Baby Behavior Questionnaire and the Life Incidence of Traumatic Events checklist. A significant group-level circadian rhythm of salivary cortisol secretion was established at one month, and remained throughout the first year of life, although there was considerable individual variability. No correlation was found between development of cortisol circadian rhythm and the results from either the Baby Behavior Questionnaire or the Life Incidence of Traumatic Events checklist. The study presents salivary cortisol reference intervals for infants during the first twelve months of life. Cortisol circadian rhythm in infants is already established by one month of age, earlier than previous studies have shown. The current study also provides first year age-related reference intervals for salivary cortisol levels in healthy, full-term infants.
Verification of Abbott 25-OH-vitamin D assay on the architect system.
Hutchinson, Katrina; Healy, Martin; Crowley, Vivion; Louw, Michael; Rochev, Yury
2017-04-01
Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS). Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs) of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients' samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125 nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24-111 nmol/L). In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland.
Sonoclot evaluation of whole blood coagulation in healthy adult dogs.
Babski, Danielle M; Brainard, Benjamin M; Krimer, Paula M; Ralph, Alan G; Pittman, Jennifer R; Koenig, Amie
2012-12-01
To establish a standard protocol for analysis of canine whole blood and generate reference intervals for healthy dogs using the Sonoclot analyzer, and to compare Sonoclot values to standard and viscoelastic coagulation tests. Prospective study. Veterinary University research facility and teaching hospital. Twelve healthy random source dogs and 52 healthy dogs from the general veterinary school population. Blood sampling for viscoelastic coagulation testing. Blood was collected from 12 healthy adult dogs by jugular venipuncture. After a rest period at room temperature of 30, 60, or 120 minutes, 340 μL of citrated blood was added to 20 μL of 0.2 M CaCl(2) in 1 of 2 cuvette types warmed to 37° C. Cuvettes contained a magnetic stir-bar with glass beads (gbACT+) or only a magnetic stir-bar (nonACT). Reference interval samples were collected from 52 healthy adult dogs and analyzed in duplicate. The ACT, CR, and PF were not affected by duration of rest period for either cuvette type. ACT variability was decreased when using gbACT+ cuvettes (P < 0.05). In normal dogs reference intervals (mean ± 2 SD) using gbACT+ cuvettes were: ACT 56.0-154.0 seconds, CR 14.85-46.0, and PF 2.1-4.05. ACT correlated to TEG R-time, K-time, and angle, while CR correlated with all TEG parameters. Fibrinogen correlated with ACT, CR, and PF. Sonoclot did not correlate with other common coagulation tests. Sonoclot provides viscoelastic evaluation of canine whole blood coagulation and correlated to several TEG parameters and fibrinogen. A standard protocol and reference intervals were established. © Veterinary Emergency and Critical Care Society 2012.
Development of Salivary Cortisol Circadian Rhythm and Reference Intervals in Full-Term Infants
Ivars, Katrin; Nelson, Nina; Theodorsson, Annette; Theodorsson, Elvar; Ström, Jakob O.; Mörelius, Evalotte
2015-01-01
Background Cortisol concentrations in plasma display a circadian rhythm in adults and children older than one year. Earlier studies report divergent results regarding when cortisol circadian rhythm is established. The present study aims to investigate at what age infants develop a circadian rhythm, as well as the possible influences of behavioral regularity and daily life trauma on when the rhythm is established. Furthermore, we determine age-related reference intervals for cortisol concentrations in saliva during the first year of life. Methods 130 healthy full-term infants were included in a prospective, longitudinal study with saliva sampling on two consecutive days, in the morning (07:30-09:30), noon (10:00-12:00) and evening (19:30-21:30), each month from birth until the infant was twelve months old. Information about development of behavioral regularity and potential exposure to trauma was obtained from the parents through the Baby Behavior Questionnaire and the Life Incidence of Traumatic Events checklist. Results A significant group-level circadian rhythm of salivary cortisol secretion was established at one month, and remained throughout the first year of life, although there was considerable individual variability. No correlation was found between development of cortisol circadian rhythm and the results from either the Baby Behavior Questionnaire or the Life Incidence of Traumatic Events checklist. The study presents salivary cortisol reference intervals for infants during the first twelve months of life. Conclusions Cortisol circadian rhythm in infants is already established by one month of age, earlier than previous studies have shown. The current study also provides first year age-related reference intervals for salivary cortisol levels in healthy, full-term infants. PMID:26086734
NASA Astrophysics Data System (ADS)
Shefer, V. A.
2015-12-01
We examine intermediate perturbed orbit proposed by the author previously, defined from the three position vectors of a small celestial body. It is shown theoretically, that at a small reference time interval covering the body positions the approximation accuracy of real motion by this orbit corresponds approximately to the fourth order of tangency. The smaller reference interval of time, the better this correspondence. Laws of variation of the methodical errors in constructing intermediate orbit subject to the length of reference time interval are deduced. According to these laws, the convergence rate of the method to the exact solution (upon reducing the reference interval of time) in the general case is higher by three orders of magnitude than in the case of conventional methods using Keplerian unperturbed orbit. The considered orbit is among the most accurate in set of orbits of their class determined by the order of tangency. The theoretical results are validated by numerical examples. The work was supported by the Ministry of Education and Science of the Russian Federation, project no. 2014/223(1567).
Weights, hematology and serum chemistry of seven species of free-ranging tropical pelagic seabirds
Work, Thierry M.
1996-01-01
I established reference values for weight, hematology, and serum chemistry for seven species of free-ranging Hawaiian tropical pelagic seabirds comprising three orders (Procellariiformes, Pelecaniformes, Charadriiformes) and six families (Procellariidae, Phaethontidae, Diomedeidae, Sulidae, Fregatidae, and Laridae). Species examined included 84 Hawaiian dark-rumped petrels (Pterodoma phaeopygia), 90 wedge-tailed shearwaters (Puffinus pacificus), 151 Laysan albatrosses (Diomedea immutabilis), 69 red-footed boobies (Sula sula), 154 red-tailed tropicbirds (Phaeton rubricauda), 90 great frigatebirds (Fregata minor), and 72 sooty terns (Sterna fuscata). Hematocrit, total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase and creatinine phosphokinase were analyzed. Among and within species, hematology and chemistry values varied with age, sex, season, and island of collection. Despite this variation, order-wide trends were observed.
Spatial interpolation of daily evapotranspiration data in the Texas High Plains
USDA-ARS?s Scientific Manuscript database
The Texas High Plains Evapotranspiration (ET) Network collects meteorological data from grass-referenced weather stations at hourly intervals and estimates hourly and daily reference ET using the American Society of Civil Engineers (ASCE) Standardized Reference ET equation. Producers in the Texas Hi...
2006-10-01
to be suitable for testing without manipulations. Survival of amphipods in the control sediment from Sequim Bay , WA was above the 90-percent level...Treatment Mean Percent Survival Coefficient of Variation (%) Negative Control ( Sequim Bay , WA) 90 ± 4 3.9 Reference (Lake Pontchartrain, LA) 95...assessed along with a perform- ance control sediment ( Sequim , WA, USA Lat. 48.0587 Long. -123.0235 and a reference sedi- ment (Lake Pontchartrain
Francis, Ben; Clarke, Joanna I; Walker, Lauren E; Brillant, Nathalie; Jorgensen, Andrea L; Park, B Kevin; Pirmohamed, Munir; Antoine, Daniel J
2018-05-02
The potential of mechanistic biomarkers to improve the prediction of drug-induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration as well as to characterize their natural variability and impact of diurnal variation. Serum samples from 200 healthy volunteers were recruited as part of a cross sectional study; of these, 50 subjects had weekly serial sampling over 3 weeks, while 24 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA-122 (miR-122), high mobility group box-1 (HMGB1), total keratin-18 (FL-K18), caspase cleaved keratin-18 (cc-K18), glutamate dehydrogenase (GLDH) and colony stimulating factor-1 (CSF-1) were assessed by validated assays. Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models (ALT 50 (41-50) U/l, miR-122 3548 (2912-4321) copies/µl, HMGB1 2.3 (2.2-2.4) ng/ml, FL-K18 475 (456-488) U/l, cc-K18 272 (256-291) U/l, GLDH 27 (26-30) U/l and CSF-1 2.4 (2.3-2.9) ng/ml). There was a small but significant intra-individual time random effect detected but no significant impact of diurnal variation was observed, with the exception of GLDH. Reference intervals for novel DILI biomarkers have been described for the first time. An upper limit of a reference range might represent the most appropriate method to utilize these data. Regulatory authorities have published letters of support encouraging further qualification of leading candidate biomarkers. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification. Drug-induced liver injury (DILI) has a big impact on patient health and the development of new medicines. Unfortunately, currently used blood-based tests to assess liver injury and recovery suffer from insufficiencies. Newer blood-based tests (biomarkers) have been described that accurately predict the onset and recovery from DILI. Here, in this study we describe reference intervals from investigations designed, for the first time, with the intension to assess the natural variation of these newer biomarkers in healthy volunteers. The outcomes of these results can be used to aid the interpretation of data from patients with suspected liver toxicity. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Briscoe, Carol
This qualitative case study focused on the role of cognitive referents in the sense-making process of one teacher as he attempted to change his classroom science assessment. The interpretations identify cultural myths, conceptual metonymys, as well as personally constructed beliefs as referents that constrained change. The teacher's cognitive struggle to make sense of assessment and his role as assessor are linked to conflicting referents he used in varying contexts including day-to-day assessment and summative assessment settings. The results of the study suggest that cognitive referents are important influences in driving how a teacher thinks about assessment and may constrain an individual teacher's implementation of innovative practices. Accordingly, identification of referents such as myths, their associated beliefs, and metonymic conceptual models that teachers use to make sense of their actions is an important first step in developing an understanding of constraints to educational change.
ENVIRONMENTAL MASS SPECTROMETRY: EMERGING CONTAMINANTS AND CURRENT ISSUES, 2004 REVIEW
This review covers developments in environmental mass spectrometry over the period of 2002-2003. A few significant references that appeared between January and March 2004 are also included. This review is in keeping with a current approach of Analytical Chemistry to include onl...
Reach for Reference. Science Online
ERIC Educational Resources Information Center
Safford, Barbara Ripp
2004-01-01
This brief article describes the database, Science Online, from Facts on File. Science is defined broadly in this database to include archeology, computer technology, medicine, inventions, and mathematics, as well as biology, chemistry, earth sciences, and astronomy. Content also is divided into format categories for browsing purposes:…
In this paper, we briefly review the atmospheric chemistry and previous intercomparison measurements for HCHO, with special reference to the diffusion scrubber-Hantzsch reaction based fluorescence instrument used in the field studies reported herein. Then we discuss summertime HC...
Chemistry of Durable and Regenerable Biocidal Textiles
ERIC Educational Resources Information Center
Gang Sun; Worley, S. Dave
2005-01-01
Antimicrobial textiles can be categorized into two groups, biocidal and biostatic materials, according to their functions. Biostatic functions refer to inhibiting growth of microorganisms on textiles and preventing the materials from biodegradation and biocidal materials are able to kill microorganisms, thus eliminating their growth, sterilizing…
Clinical chemistry and hematology values in a Caribbean population of African green monkeys.
Liddie, Shervin; Goody, Robin J; Valles, Rodrigo; Lawrence, Matthew S
2010-12-01
Hematology and clinical chemistry (HCC) reference values are critical in veterinary practice and in vivo pre-clinical research, enabling detection of health abnormalities, response to therapeutic intervention or adverse toxicological effects, as well as monitoring of clinical management. In this report, reference ranges for 46 HCC parameters were characterized in 331 wild-caught and colony-bred African green monkeys. Effects of sex, weight and duration of captivity were determined by one-way analysis of variance. Significant sex differences were observed for several HCC parameters. Significant differences were also observed for select HCC variables between newly caught animals and those held in captivity for 1-12 months or longer. Comparison of this data with other non-human primate species and humans highlights similarities and disparities between species. Potential causes of interpopulation variability and relevance to the use of the African green monkey as a non-human primate model are discussed. © 2010 John Wiley & Sons A/S.
Lourens, A C U; Viljoen, A M; van Heerden, F R
2008-10-28
In South Africa, the genus Helichrysum is widely used in traditional medicine. The uses are well documented although renaming of species and the resulting confusing taxonomic nomenclature may cause uncertainty as to which specific species was referred to in some reports. The aim of this paper is to present a collated and coherent overview of the documented traditional uses of Helichrysum species and to update the botanical identity of previously studied species. Databases (Scifinder, ISI Web of Knowledge) and several books were used to collect in information on South African Helichrysum species. The traditional uses, chemistry and biological activity of Helichrysum species have been summarized. It was attempted to give clarity as to exactly which species is refer to in the ethnobotanical literature. Although a large number of ethnopharmacological uses have been documented and the chemistry of the genus has been studied extensively, only a few South African species have been investigated for their biological activity.
Plasma Processes for Semiconductor Fabrication
NASA Astrophysics Data System (ADS)
Hitchon, W. N. G.
1999-01-01
Plasma processing is a central technique in the fabrication of semiconductor devices. This self-contained book provides an up-to-date description of plasma etching and deposition in semiconductor fabrication. It presents the basic physics and chemistry of these processes, and shows how they can be accurately modeled. The author begins with an overview of plasma reactors and discusses the various models for understanding plasma processes. He then covers plasma chemistry, addressing the effects of different chemicals on the features being etched. Having presented the relevant background material, he then describes in detail the modeling of complex plasma systems, with reference to experimental results. The book closes with a useful glossary of technical terms. No prior knowledge of plasma physics is assumed in the book. It contains many homework exercises and serves as an ideal introduction to plasma processing and technology for graduate students of electrical engineering and materials science. It will also be a useful reference for practicing engineers in the semiconductor industry.
Hematology, plasma chemistry, and bacteriology of wild Tundra Swans (Cygnus columbianus) in Alaska.
Milani, Juliana F; Wilson, Heather; Ziccardi, Michael; LeFebvre, Rance; Scott, Cheryl
2012-01-01
Blood and cloacal swabs were collected from 100 (66 female, 34 male) wild Tundra Swans (Cygnus columbianus) molting in northwestern Alaska, USA, 25-28 July 2008, to establish hematologic and serum chemistry reference values and to isolate enteric Salmonella spp. and Escherichia coli O157:H7. Plasma biochemistry and hematology values did not vary significantly by sex or age. Tundra swans had high levels of creatine kinase, lactate dehydrogenase, amylase, and alkaline phosphatase compared with some other avian species (values were up to 7 times greater), possibly indicating capture myopathy. However, concentrations were much lower (up to 8 times lower) than in other waterfowl exposed to similar or more intensive capture methods. White blood cell count and hematocrit values were similar to other waterfowl species, and enteric Salmonella spp. and E. coli O157:H7 were not present among birds sampled. Our data provide the first biochemical, hematologic, and bacteriologic reference values for wild Tundra Swans.
The Use of One-Sample Prediction Intervals for Estimating CO2 Scrubber Canister Durations
2012-10-01
Grade and 812 D-Grade Sofnolime.3 Definitions According to Devore,4 A CI (confidence interval) refers to a parameter, or population ... characteristic , whose value is fixed but unknown to us. In contrast, a future value of Y is not a parameter but instead a random variable; for this
40 CFR 1066.605 - Mass-based and molar-based exhaust emission calculations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the test interval, corrected to standard temperature and pressure. m PMfil = mass of particulate... = stabilized, ht = hot transient), corrected to standard reference conditions. m PMfil = mass of particulate... stabilized), corrected to standard reference conditions. m PMfil = mass of particulate matter emissions on...
Selecting automation for the clinical chemistry laboratory.
Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr
2007-07-01
Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.
4D Dynamic Required Navigation Performance Final Report
NASA Technical Reports Server (NTRS)
Finkelsztein, Daniel M.; Sturdy, James L.; Alaverdi, Omeed; Hochwarth, Joachim K.
2011-01-01
New advanced four dimensional trajectory (4DT) procedures under consideration for the Next Generation Air Transportation System (NextGen) require an aircraft to precisely navigate relative to a moving reference such as another aircraft. Examples are Self-Separation for enroute operations and Interval Management for in-trail and merging operations. The current construct of Required Navigation Performance (RNP), defined for fixed-reference-frame navigation, is not sufficiently specified to be applicable to defining performance levels of such air-to-air procedures. An extension of RNP to air-to-air navigation would enable these advanced procedures to be implemented with a specified level of performance. The objective of this research effort was to propose new 4D Dynamic RNP constructs that account for the dynamic spatial and temporal nature of Interval Management and Self-Separation, develop mathematical models of the Dynamic RNP constructs, "Required Self-Separation Performance" and "Required Interval Management Performance," and to analyze the performance characteristics of these air-to-air procedures using the newly developed models. This final report summarizes the activities led by Raytheon, in collaboration with GE Aviation and SAIC, and presents the results from this research effort to expand the RNP concept to a dynamic 4D frame of reference.
Shields, E; Seiden-Long, I; Massie, S; Passante, S; Leguillette, R
2016-06-13
Cardiac troponin-I assays have been validated in horses.'High-sensitivity' cardiac troponin assays are now the standard in human cardiology. Appropriately validate the'high-sensitivity' cardiac Troponin-T (hscTnT) assay for clinical use in horses, establish reference intervals, determine the biological variation, and demonstrate assay utility in selected clinical cases. Analytical validation of the Roche hscTnT assay included within- and between-run precision, linear dose response, limit of quantitation (LoQ), stability, and comparison with cTn-I (iSTAT). Reference intervals and biological variation were determined using adult, healthy, Non-Competition Horses (N = 125) and Racing-Thoroughbreds (N = 178). HscTnT levels were measured in two horses with cardiac pathology. The hscTnT demonstrates acceptable within-run (L1 = 6.5 ng/L, CV 14.9 %, L2 = 10.1 ng/L, CV 8.7 %, L3 = 15.3 ng/L, CV 5.4 %) and between-run precision (L1 = 12.2 ng/L, CV 8.4 %, L2 = 57.0 ng/L, CV 8.4 %, L3 = 256.0 ng/L, CV 9.0 %). The assay was linear from 3 to 391 ng/L. The LoQ was validated at 3 ng/L. Samples demonstrated insignificant decay over freeze-thaw cycle. Comparison with cTnI assay showed excellent correlation (range: 8.0-3535.0 ng/L, R(2) = 0.9996). Reference intervals: The upper 95(th) and 99(th) percentile of the hscTnT population distribution were 6.8 and 16.2 ng/L in Non-Competition Horses, and 14.0 and 23.2 ng/L in Racing-Thoroughbreds. Between-breed, diurnal effect, and between-day variation was below LoQ. Two clinical cases with presumed cardiac pathology had hscTnT levels of 220.9 ng/L and 5723.0 ng/L. This benchmark study is the first to comply with CLSI guidelines, thus further establishing the performance characteristics of the hscTnT assay, and reference intervals in healthy horses. Two clinical cases demonstrated further the clinical utility of the assay.
Certification of biological candidates reference materials by neutron activation analysis
NASA Astrophysics Data System (ADS)
Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.
2018-03-01
The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.
Delanghe, Joris R; Cobbaert, Christa; Galteau, Marie-Madeleine; Harmoinen, Aimo; Jansen, Rob; Kruse, Rolf; Laitinen, Päivi; Thienpont, Linda M; Wuyts, Birgitte; Weykamp, Cas; Panteghini, Mauro
2008-01-01
The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are described, in which 189 European laboratories analyzed serum creatinine in a commutable serum-based material, using analytical systems from seven companies. Values were targeted using isotope dilution gas chromatography/mass spectrometry. Results were tested on their compliance to a set of three criteria: trueness, i.e., no significant bias relative to the target value, between-laboratory variation and within-laboratory variation relative to the maximum allowable error. For the lower and intermediate level, values differed significantly from the target value in the Jaffe and the dry chemistry methods. At the high level, dry chemistry yielded higher results. Between-laboratory coefficients of variation ranged from 4.37% to 8.74%. Total error budget was mainly consumed by the bias. Non-compensated Jaffe methods largely exceeded the total error budget. Best results were obtained for the enzymatic method. The dry chemistry method consumed a large part of its error budget due to calibration bias. Despite the European IVD directive and the growing needs for creatinine standardization, an unacceptable inter-laboratory variation was observed, which was mainly due to calibration differences. The calibration variation has major clinical consequences, in particular in pediatrics, where reference ranges for serum and plasma creatinine are low, and in the estimation of glomerular filtration rate.
Modification of the flow pass method as applied to problems of chemistry of planet atmospheres
NASA Technical Reports Server (NTRS)
Parshev, V. A.
1980-01-01
It was shown that the modified flow pass method possesses considerable effectiveness, both in the case when the coefficient of diffusion changes severely in the examined region and in the case when diffusion is the prevalent process, as compared with chemical reactions. The case when a regular pass proves inapplicable, or applicable in a limited interval of the decisive parameters, was examined.
The Application of a Statistical Analysis Software Package to Explosive Testing
1993-12-01
deviation not corrected for test interval. M refer to equation 2. s refer to equation 3. G refer to section 2.1, C 36 Appendix I : Program Structured ...APPENDIX I: Program Structured Diagrams 37 APPENDIX II: Bruceton Reference Graphs 39 APPENDIX III: Input and Output Data File Format 44 APPENDIX IV...directly from Graph II, which has been digitised and incorporated into the program . IfM falls below 0.3, the curve that is closest to diff( eq . 3a) is
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ostlund, Neil
This research showed the feasibility of applying the concepts of the Semantic Web to Computation Chemistry. We have created the first web portal (www.chemsem.com) that allows data created in the calculations of quantum chemistry, and other such chemistry calculations to be placed on the web in a way that makes the data accessible to scientists in a semantic form never before possible. The semantic web nature of the portal allows data to be searched, found, and used as an advance over the usual approach of a relational database. The semantic data on our portal has the nature of a Giantmore » Global Graph (GGG) that can be easily merged with related data and searched globally via a SPARQL Protocol and RDF Query Language (SPARQL) that makes global searches for data easier than with traditional methods. Our Semantic Web Portal requires that the data be understood by a computer and hence defined by an ontology (vocabulary). This ontology is used by the computer in understanding the data. We have created such an ontology for computational chemistry (purl.org/gc) that encapsulates a broad knowledge of the field of computational chemistry. We refer to this ontology as the Gainesville Core. While it is perhaps the first ontology for computational chemistry and is used by our portal, it is only a start of what must be a long multi-partner effort to define computational chemistry. In conjunction with the above efforts we have defined a new potential file standard (Common Standard for eXchange – CSX for computational chemistry data). This CSX file is the precursor of data in the Resource Description Framework (RDF) form that the semantic web requires. Our portal translates CSX files (as well as other computational chemistry data files) into RDF files that are part of the graph database that the semantic web employs. We propose a CSX file as a convenient way to encapsulate computational chemistry data.« less
The Nature of the Chemical Bond--1990.
ERIC Educational Resources Information Center
Ogilvie, J. F.
1990-01-01
Three aspects of quantum mechanics in modern chemistry are stressed: the fundamental structure of quantum mechanics as a basis of chemical applications, the relationship of quantum mechanics to atomic and molecular structure, and the consequent implications for chemical education. A list of 64 references is included. (CW)
ERIC Educational Resources Information Center
Wayne, Randy; Staves, Mark P.
1998-01-01
Details the teaching of an undergraduate plant-cell biology class in the manner proposed by Jean Baptiste Carnoy when he established the first institute of cellular biology. Integrates mathematics, astronomy, physics, chemistry, anatomy, physiology, and ecology. Contains 226 references. (DDR)
Identification of unknowns in mass spectrometry based non-targeted analyses (NTA) requires the integration of complementary pieces of data to arrive at a confident, consensus structure. Researchers use chemical reference databases, spectral matching, fragment prediction tools, r...
The Analysis of Seawater: A Laboratory-Centered Learning Project in General Chemistry.
ERIC Educational Resources Information Center
Selco, Jodye I.; Roberts, Julian L., Jr.; Wacks, Daniel B.
2003-01-01
Describes a sea-water analysis project that introduces qualitative and quantitative analysis methods and laboratory methods such as gravimetric analysis, potentiometric titration, ion-selective electrodes, and the use of calibration curves. Uses a problem-based cooperative teaching approach. (Contains 24 references.) (YDS)
NASA Astrophysics Data System (ADS)
Eibern, Hendrik; Schmidt, Hauke
1999-08-01
The inverse problem of data assimilation of tropospheric trace gas observations into an Eulerian chemistry transport model has been solved by the four-dimensional variational technique including chemical reactions, transport, and diffusion. The University of Cologne European Air Pollution Dispersion Chemistry Transport Model 2 with the Regional Acid Deposition Model 2 gas phase mechanism is taken as the basis for developing a full four-dimensional variational data assimilation package, on the basis of the adjoint model version, which includes the adjoint operators of horizontal and vertical advection, implicit vertical diffusion, and the adjoint gas phase mechanism. To assess the potential and limitations of the technique without degrading the impact of nonperfect meteorological analyses and statistically not established error covariance estimates, artificial meteorological data and observations are used. The results are presented on the basis of a suite of experiments, where reduced records of artificial "observations" are provided to the assimilation procedure, while other "data" is retained for performance control of the analysis. The paper demonstrates that the four-dimensional variational technique is applicable for a comprehensive chemistry transport model in terms of computational and storage requirements on advanced parallel platforms. It is further shown that observed species can generally be analyzed, even if the "measurements" have unbiased random errors. More challenging experiments are presented, aiming to tax the skill of the method (1) by restricting available observations mostly to surface ozone observations for a limited assimilation interval of 6 hours and (2) by starting with poorly chosen first guess values. In this first such application to a three-dimensional chemistry transport model, success was also achieved in analyzing not only observed but also chemically closely related unobserved constituents.
Armando García-Miranda, L; Contreras, I; Estrada, J A
2014-04-01
To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.
Sridevi, Ganapathi; Minocha, Rakesh; Turlapati, Swathi A; Goldfarb, Katherine C; Brodie, Eoin L; Tisa, Louis S; Minocha, Subhash C
2012-03-01
Soil Ca depletion because of acidic deposition-related soil chemistry changes has led to the decline of forest productivity and carbon sequestration in the northeastern USA. In 1999, acidic watershed (WS) 1 at the Hubbard Brook Experimental Forest (HBEF), NH, USA was amended with Ca silicate to restore soil Ca pools. In 2006, soil samples were collected from the Ca-amended (WS1) and reference watershed (WS3) for comparison of bacterial community composition between the two watersheds. The sites were about 125 m apart and were known to have similar stream chemistry and tree populations before Ca amendment. Ca-amended soil had higher Ca and P, and lower Al and acidity as compared with the reference soils. Analysis of bacterial populations by PhyloChip revealed that the bacterial community structure in the Ca-amended and the reference soils was significantly different and that the differences were more pronounced in the mineral soils. Overall, the relative abundance of 300 taxa was significantly affected. Numbers of detectable taxa in families such as Acidobacteriaceae, Comamonadaceae, and Pseudomonadaceae were lower in the Ca-amended soils, while Flavobacteriaceae and Geobacteraceae were higher. The other functionally important groups, e.g. ammonia-oxidizing Nitrosomonadaceae, had lower numbers of taxa in the Ca-amended organic soil but higher in the mineral soil. Published 2011. This article is a U.S. Government work and is in the public domain in the USA.
Zwetsloot, Marie J; Lehmann, Johannes; Solomon, Dawit
2015-01-01
Pyrolysis of slaughterhouse waste could promote more sustainable phosphorus (P) usage through the development of alternative P fertilizers. This study investigated how pyrolysis temperature (220, 350, 550 and 750 °C), rendering before pyrolysis, and wood or corn biomass additions affect P chemistry in bone char, plant availability, and its potential as P fertilizer. Linear combination fitting of synchrotron-based X-ray absorption near edge structure spectra demonstrated that higher pyrolysis temperatures decreased the fit with organic P references, but increased the fit with a hydroxyapatite (HA) reference, used as an indicator of high calcium phosphate (CaP) crystallinity. The fit to the HA reference increased from 0% to 69% in bone with meat residue and from 20% to 95% in rendered bone. Biomass additions to the bone with meat residue reduced the fit to the HA reference by 83% for wood and 95% for corn, and additions to rendered bone by 37% for wood. No detectable aromatic P forms were generated by pyrolysis. High CaP crystallinity was correlated with low water-extractable P, but high formic acid-extractable P indicative of high plant availability. Bone char supplied available P which was only 24% lower than Triple Superphosphate fertilizer and two- to five-fold higher than rock phosphate. Pyrolysis temperature and biomass additions can be used to design P fertilizer characteristics of bone char through changing CaP crystallinity that optimize P availability to plants. © 2014 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Haussaire, Jean-Matthieu; Bocquet, Marc
2016-04-01
Atmospheric chemistry models are becoming increasingly complex, with multiphasic chemistry, size-resolved particulate matter, and possibly coupled to numerical weather prediction models. In the meantime, data assimilation methods have also become more sophisticated. Hence, it will become increasingly difficult to disentangle the merits of data assimilation schemes, of models, and of their numerical implementation in a successful high-dimensional data assimilation study. That is why we believe that the increasing variety of problems encountered in the field of atmospheric chemistry data assimilation puts forward the need for simple low-order models, albeit complex enough to capture the relevant dynamics, physics and chemistry that could impact the performance of data assimilation schemes. Following this analysis, we developped a low-order coupled chemistry meteorology model named L95-GRS [1]. The advective wind is simulated by the Lorenz-95 model, while the chemistry is made of 6 reactive species and simulates ozone concentrations. With this model, we carried out data assimilation experiments to estimate the state of the system as well as the forcing parameter of the wind and the emissions of chemical compounds. This model proved to be a powerful playground giving insights on the hardships of online and offline estimation of atmospheric pollution. Building on the results on this low-order model, we test advanced data assimilation methods on a state-of-the-art chemical transport model to check if the conclusions obtained with our low-order model still stand. References [1] Haussaire, J.-M. and Bocquet, M.: A low-order coupled chemistry meteorology model for testing online and offline data assimilation schemes, Geosci. Model Dev. Discuss., 8, 7347-7394, doi:10.5194/gmdd-8-7347-2015, 2015.
Identifying known unknowns using the US EPA's CompTox ...
Chemical features observed using high-resolution mass spectrometry can be tentatively identified using online chemical reference databases by searching molecular formulae and monoisotopic masses and then rank-ordering of the hits using appropriate relevance criteria. The most likely candidate “known unknowns,” which are those chemicals unknown to an investigator but contained within a reference database or literature source, rise to the top of a chemical list when rank-ordered by the number of associated data sources. The U.S. EPA’s CompTox Chemistry Dashboard is a curated and freely available resource for chemistry and computational toxicology research, containing more than 720,000 chemicals of relevance to environmental health science. In this research, the performance of the Dashboard for identifying “known unknowns” was evaluated against that of the online ChemSpider database, one of the primary resources used by mass spectrometrists, using multiple previously studied datasets reported in the peer-reviewed literature totaling 162 chemicals. These chemicals were examined using both applications via molecular formula and monoisotopic mass searches followed by rank-ordering of candidate compounds by associated references or data sources. A greater percentage of chemicals ranked in the top position when using the Dashboard, indicating an advantage of this application over ChemSpider for identifying known unknowns using data source ranking. Addition
Physiologic Reference Ranges for Captive Black-Tailed Prairie Dogs (Cynomys ludovicianus)
Keckler, M Shannon; Gallardo-Romero, Nadia F; Langham, Gregory L; Damon, Inger K; Karem, Kevin L; Carroll, Darin S
2010-01-01
The black-tailed prairie dog (Cynomys ludovicianus) is a member of the order Rodentia and the family Sciuridae. Ecologically, prairie dogs are a keystone species in prairie ecology. This species is used as an animal model for human gallbladder disease and diseases caused by infection with Clostridium difficile, Yersinia pestis, Francisella tularensis, and most recently, Orthopoxvirus. Despite increasing numbers of prairie dogs used in research and kept as pets, few data are available on their baseline physiology in animal facility housing conditions. To establish baseline physiologic reference ranges, we designed a study using 18 wild-caught black-tailed prairie dogs. Telemetry data were analyzed to establish circadian rhythms for activity and temperature. In addition, hematologic and serum chemistry analyses were performed. Baseline measurements were used to establish the mean for each animal, which then were compiled and analyzed to determine the reference ranges. Here we present physiologic data on serum chemistry and hematology profiles, as well as weight, core body temperature, and daily activity patterns for black-tailed prairie dogs. These results reflect the use of multiple measurements from species- and age-matched prairie dogs and likely will be useful to ecologists, scientists interested in using this animal model in research, and veterinarians caring for pet prairie dogs. PMID:20587156
Autoverification process improvement by Six Sigma approach: Clinical chemistry & immunoassay.
Randell, Edward W; Short, Garry; Lee, Natasha; Beresford, Allison; Spencer, Margaret; Kennell, Marina; Moores, Zoë; Parry, David
2018-05-01
This study examines effectiveness of a project to enhance an autoverification (AV) system through application of Six Sigma (DMAIC) process improvement strategies. Similar AV systems set up at three sites underwent examination and modification to produce improved systems while monitoring proportions of samples autoverified, the time required for manual review and verification, sample processing time, and examining characteristics of tests not autoverified. This information was used to identify areas for improvement and monitor the impact of changes. Use of reference range based criteria had the greatest impact on the proportion of tests autoverified. To improve AV process, reference range based criteria was replaced with extreme value limits based on a 99.5% test result interval, delta check criteria were broadened, and new specimen consistency rules were implemented. Decision guidance tools were also developed to assist staff using the AV system. The mean proportion of tests and samples autoverified improved from <62% for samples and <80% for tests, to >90% for samples and >95% for tests across all three sites. The new AV system significantly decreased turn-around time and total sample review time (to about a third), however, time spent for manual review of held samples almost tripled. There was no evidence of compromise to the quality of testing process and <1% of samples held for exceeding delta check or extreme limits required corrective action. The Six Sigma (DMAIC) process improvement methodology was successfully applied to AV systems resulting in an increase in overall test and sample AV by >90%, improved turn-around time, reduced time for manual verification, and with no obvious compromise to quality or error detection. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Simpson, Colin R; Steiner, Markus Fc; Cezard, Genevieve; Bansal, Narinder; Fischbacher, Colin; Douglas, Anne; Bhopal, Raj; Sheikh, Aziz
2015-10-01
There is evidence of substantial ethnic variations in asthma morbidity and the risk of hospitalisation, but the picture in relation to lower respiratory tract infections is unclear. We carried out an observational study to identify ethnic group differences for lower respiratory tract infections. A retrospective, cohort study. Scotland. 4.65 million people on whom information was available from the 2001 census, followed from May 2001 to April 2010. Hospitalisations and deaths (any time following first hospitalisation) from lower respiratory tract infections, adjusted risk ratios and hazard ratios by ethnicity and sex were calculated. We multiplied ratios and confidence intervals by 100, so the reference Scottish White population's risk ratio and hazard ratio was 100. Among men, adjusted risk ratios for lower respiratory tract infection hospitalisation were lower in Other White British (80, 95% confidence interval 73-86) and Chinese (69, 95% confidence interval 56-84) populations and higher in Pakistani groups (152, 95% confidence interval 136-169). In women, results were mostly similar to those in men (e.g. Chinese 68, 95% confidence interval 56-82), although higher adjusted risk ratios were found among women of the Other South Asians group (145, 95% confidence interval 120-175). Survival (adjusted hazard ratio) following lower respiratory tract infection for Pakistani men (54, 95% confidence interval 39-74) and women (31, 95% confidence interval 18-53) was better than the reference population. Substantial differences in the rates of lower respiratory tract infections amongst different ethnic groups in Scotland were found. Pakistani men and women had particularly high rates of lower respiratory tract infection hospitalisation. The reasons behind the high rates of lower respiratory tract infection in the Pakistani community are now required. © The Royal Society of Medicine.
Quo vadis, analytical chemistry?
Valcárcel, Miguel
2016-01-01
This paper presents an open, personal, fresh approach to the future of Analytical Chemistry in the context of the deep changes Science and Technology are anticipated to experience. Its main aim is to challenge young analytical chemists because the future of our scientific discipline is in their hands. A description of not completely accurate overall conceptions of our discipline, both past and present, to be avoided is followed by a flexible, integral definition of Analytical Chemistry and its cornerstones (viz., aims and objectives, quality trade-offs, the third basic analytical reference, the information hierarchy, social responsibility, independent research, transfer of knowledge and technology, interfaces to other scientific-technical disciplines, and well-oriented education). Obsolete paradigms, and more accurate general and specific that can be expected to provide the framework for our discipline in the coming years are described. Finally, the three possible responses of analytical chemists to the proposed changes in our discipline are discussed.
Contribution of Surface Chemistry to the Shear Thickening of Silica Nanoparticle Suspensions.
Yang, Wufang; Wu, Yang; Pei, Xiaowei; Zhou, Feng; Xue, Qunji
2017-01-31
Shear thickening is a general process crucial for many processed products ranging from food and personal care to pharmaceuticals. Theoretical calculations and mathematical simulations of hydrodynamic interactions and granular-like contacts have proved that contact forces between suspended particles dominate the rheological characteristic of colloidal suspensions. However, relevant experimental studies are very rare. This study was conducted to reveal the influence of nanoparticle (NP) interactions on the rheological behavior of shear-thickening fluids (STFs) by changing the colloidal surface chemistries. Silica NPs with various surface chemical compositions are fabricated and used to prepare dense suspensions. Rheological experiments are conducted to determine the influence of NP interactions on corresponding dense suspension systems. The results suggest that the surface chemistries of silica NPs determine the rheological behavior of dense suspensions, including shear-thickening behavior, onset stress, critical volume fraction, and jamming volume fraction. This study provides useful reference for designing effective STFs and regulating their characteristics.
NASA Astrophysics Data System (ADS)
Ouk, Chanda-Malis; Zvereva-Loëte, Natalia; Bussery-Honvault, Béatrice
2011-10-01
The N( 2D) + CH 4 reaction appears to be a key reaction for the chemistry of Titan's atmosphere, opening the door to nitrile formation as recently observed by the Cassini-Huygens mission. Faced to the controversy concerning the existence or not of a potential barrier for this reaction, we have carried out accurate ab initio calculations by means of multi-state multi-reference configuration interaction (MS-MR-SDCI) method. These calculations have been partially corrected for the size-consistency errors (SCE) by Davidson, Pople or AQCC corrections. We suggest a barrier height of 3.86 ± 0.84 kJ/mol, including ZPE, for the entrance transition state, in good agreement with the experimental value. Its implication in Titan's atmopsheric chemistry is discussed.
Chemical Oceanography and the Marine Carbon Cycle
NASA Astrophysics Data System (ADS)
Emerson, Steven; Hedges, John
The principles of chemical oceanography provide insight into the processes regulating the marine carbon cycle. The text offers a background in chemical oceanography and a description of how chemical elements in seawater and ocean sediments are used as tracers of physical, biological, chemical and geological processes in the ocean. The first seven chapters present basic topics of thermodynamics, isotope systematics and carbonate chemistry, and explain the influence of life on ocean chemistry and how it has evolved in the recent (glacial-interglacial) past. This is followed by topics essential to understanding the carbon cycle, including organic geochemistry, air-sea gas exchange, diffusion and reaction kinetics, the marine and atmosphere carbon cycle and diagenesis in marine sediments. Figures are available to download from www.cambridge.org/9780521833134. Ideal as a textbook for upper-level undergraduates and graduates in oceanography, environmental chemistry, geochemistry and earth science and a valuable reference for researchers in oceanography.
What Is Feminist Pedagogy? Useful Ideas for Teaching Chemistry
NASA Astrophysics Data System (ADS)
Hurt Middlecamp, Catherine; Subramaniam, Banu
1999-04-01
In our experience, scientists are likely to be newcomers to the scholarship that has arisen from the field of women's studies. This paper will examine one such area of scholarship, feminist pedagogy, and relate it to the teaching and learning of chemistry. More correctly, one should refer to feminist pedagogies, as this scholarship is evolving and is a topic for continual debate. Generally speaking, feminist pedagogies share a number of themes: a focus on women/gender, authority, position, empowerment, voice, and non-neutrality. Each of these themes is described and then applied to the chemistry classroom. Examples include using technology to give students a voice, using same-sex groupings, instituting a class board of directors, examining textbook questions, and asking new or different questions as you teach. Although feminist pedagogy aims to make science classrooms and laboratories more hospitable to women, it can inform our teaching practices and benefit all our students.
Magnetic Resonance Fingerprinting with short relaxation intervals.
Amthor, Thomas; Doneva, Mariya; Koken, Peter; Sommer, Karsten; Meineke, Jakob; Börnert, Peter
2017-09-01
The aim of this study was to investigate a technique for improving the performance of Magnetic Resonance Fingerprinting (MRF) in repetitive sampling schemes, in particular for 3D MRF acquisition, by shortening relaxation intervals between MRF pulse train repetitions. A calculation method for MRF dictionaries adapted to short relaxation intervals and non-relaxed initial spin states is presented, based on the concept of stationary fingerprints. The method is applicable to many different k-space sampling schemes in 2D and 3D. For accuracy analysis, T 1 and T 2 values of a phantom are determined by single-slice Cartesian MRF for different relaxation intervals and are compared with quantitative reference measurements. The relevance of slice profile effects is also investigated in this case. To further illustrate the capabilities of the method, an application to in-vivo spiral 3D MRF measurements is demonstrated. The proposed computation method enables accurate parameter estimation even for the shortest relaxation intervals, as investigated for different sampling patterns in 2D and 3D. In 2D Cartesian measurements, we achieved a scan acceleration of more than a factor of two, while maintaining acceptable accuracy: The largest T 1 values of a sample set deviated from their reference values by 0.3% (longest relaxation interval) and 2.4% (shortest relaxation interval). The largest T 2 values showed systematic deviations of up to 10% for all relaxation intervals, which is discussed. The influence of slice profile effects for multislice acquisition is shown to become increasingly relevant for short relaxation intervals. In 3D spiral measurements, a scan time reduction of 36% was achieved, maintaining the quality of in-vivo T1 and T2 maps. Reducing the relaxation interval between MRF sequence repetitions using stationary fingerprint dictionaries is a feasible method to improve the scan efficiency of MRF sequences. The method enables fast implementations of 3D spatially resolved MRF. Copyright © 2017 Elsevier Inc. All rights reserved.
Cape Canaveral, Florida range reference atmosphere 0-70 km altitude
NASA Technical Reports Server (NTRS)
Tingle, A. (Editor)
1983-01-01
The RRA contains tabulations for monthly and annual means, standard deviations, skewness coefficients for wind speed, pressure temperature, density, water vapor pressure, virtual temperature, dew-point temperature, and the means and standard deviations for the zonal and meridional wind components and the linear (product moment) correlation coefficient between the wind components. These statistical parameters are tabulated at the station elevation and at 1 km intervals from sea level to 30 km and at 2 km intervals from 30 to 90 km altitude. The wind statistics are given at approximately 10 m above the station elevations and at altitudes with respect to mean sea level thereafter. For those range sites without rocketsonde measurements, the RRAs terminate at 30 km altitude or they are extended, if required, when rocketsonde data from a nearby launch site are available. There are four sets of tables for each of the 12 monthly reference periods and the annual reference period.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, G.E.; Parent, D.R.
1974-01-01
Concentrations of sodium, calcium, magnesium, potassium, phosphorus and nitrate were measured in throughfall under isolated douglas fir (Pseudotsuga menziesii var. glauca) and Rocky Mountain juniper (Juniperus scopulorum) trees in northern Utah for 39 storms in 1970 and 1971. Concentrations were 3-16 times greater under the trees than in the open. Throughfall under douglas fir invariably had higher concentrations than that under juniper. Since most of the chemical input occurs as dry fallout between storms, surface area and form of the canopy are believed to be the prime factors influencing throughfall chemistry in this region. 15 references, 2 figures, 5 tables.
Synthetic Aziridines in Medicinal Chemistry: A Mini-Review.
Singh, Girija S
2016-01-01
Azaheterocyclic compounds are well-known to have diverse types of biological activity. Among them, azacyclopropanes, commonly referred as aziridines, occupy a prominent place in synthetic organic and medicinal chemistry due to its occurrence in natural resources, complexity involved in synthesis due to ring-strain, building blocks in organic synthesis, and its biological properties. Several novel compounds containing aziridine ring have been designed and synthesized recently by medicinal chemists for evaluating their biological profile. A number of compounds are reported as cysteine protease inhibitors, antibacterial, antifungal, anticancer, antileishmanial, and antimalarial agents. This review article summarizes the biological activity of such compounds. The preparation of such compounds is also described.
NASA Astrophysics Data System (ADS)
Medvedev, J. J.; Nikolaev, V. A.
2015-07-01
Multicomponent reactions of diazo compounds catalyzed by RhII complexes become a powerful tool for organic synthesis. They enable three- or four-step processes to be carried out as one-pot procedures (actually as one step) with high stereoselectivity to give complex organic molecules, including biologically active compounds. This review addresses recent results in the chemistry of Rh-catalyzed multicomponent reactions of diazocarbonyl compounds with the intermediate formation of N-, O- and C=O-ylides. The diastereo- and enantioselectivity of these reactions and the possibility of using various co-catalysts to increase the efficiency of the processes under consideration are discussed. The bibliography includes 120 references.
Algorithmic, LOCS and HOCS (chemistry) exam questions: performance and attitudes of college students
NASA Astrophysics Data System (ADS)
Zoller, Uri
2002-02-01
The performance of freshmen biology and physics-mathematics majors and chemistry majors as well as pre- and in-service chemistry teachers in two Israeli universities on algorithmic (ALG), lower-order cognitive skills (LOCS), and higher-order cognitive skills (HOCS) chemistry exam questions were studied. The driving force for the study was an interest in moving science and chemistry instruction from an algorithmic and factual recall orientation dominated by LOCS, to a decision-making, problem-solving and critical system thinking approach, dominated by HOCS. College students' responses to the specially designed ALG, LOCS and HOCS chemistry exam questions were scored and analysed for differences and correlation between the performance means within and across universities by the questions' category. This was followed by a combined student interview - 'speaking aloud' problem solving session for assessing the thinking processes involved in solving these types of questions and the students' attitudes towards them. The main findings were: (1) students in both universities performed consistently in each of the three categories in the order of ALG > LOCS > HOCS; their 'ideological' preference, was HOCS > algorithmic/LOCS, - referred to as 'computational questions', but their pragmatic preference was the reverse; (2) success on algorithmic/LOCS does not imply success on HOCS questions; algorithmic questions constitute a category on its own as far as students success in solving them is concerned. Our study and its results support the effort being made, worldwide, to integrate HOCS-fostering teaching and assessment strategies and, to develop HOCS-oriented science-technology-environment-society (STES)-type curricula within science and chemistry education.
Coplen, T.B.; Qi, H.
2009-01-01
New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.
Identification of unknowns in mass spectrometry based non-targeted analyses (NTA) requires the integration of complementary pieces of data to arrive at a confident, consensus structure. Researchers use chemical reference databases, spectral matching, fragment prediction tools, r...
The Museum of Science and Industry Basic List of Children's Science Books 1973-1984.
ERIC Educational Resources Information Center
Richter, Bernice; Wenzel, Duane
Children's science books are listed under these headings: animals; astronomy; aviation and space; biography; careers; earth sciences; encyclopedias and reference books; environment and conservation; fiction; general science; life sciences; marine life; mathematics and computer science; medical and health sciences; physics and chemistry; plant…
Modeling Nuclear Decay: A Point of Integration between Chemistry and Mathematics.
ERIC Educational Resources Information Center
Crippen, Kent J.; Curtright, Robert D.
1998-01-01
Describes four activities that use graphing calculators to model nuclear-decay phenomena. Students ultimately develop a notion about the radioactive waste produced by nuclear fission. These activities are in line with national educational standards and allow for the integration of science and mathematics. Contains 13 references. (Author/WRM)
The State of Organic Teaching Laboratories
ERIC Educational Resources Information Center
Horowitz, Gail
2007-01-01
The changes that have taken place in the organic chemistry laboratory course since 1980s are reviewed with reference to the quantity and diversity of discovery-based experiments available to date. The data illustrates that significant progress is towards accomplishing dramatic changes such as the almost universal adoption of microscale, the use of…
Promoting Chemistry at the Elementary Level: A Low-Maintenance Program of Chemical Demonstrations.
ERIC Educational Resources Information Center
Louters, Larry L.; Huisman, Richard D.
1999-01-01
Presents a chemical demonstration program designed to support elementary science education in which fifth- and sixth-grade students visit a college campus to watch chemical demonstrations performed by a professor. Contains suggestions for program set-up and references for demonstrations to use. (WRM)
USDA-ARS?s Scientific Manuscript database
An easy, rapid, and inexpensive method was developed to measure total, soluble, and insoluble starch in products at the factory and refinery, using microwave-assisted neutralization chemistry. The method was optimized using the previously developed USDA Starch Research method as a reference. Optimal...
Cis and Trans Isomers of Cycloalkenes
ERIC Educational Resources Information Center
Barrows, Susan E.; Eberlein, Thomas H.
2005-01-01
A study investigates the strain in medium-sized cycloalkenes and the geometric and electronic distortions through which alkenes can relieve that strain. Literature data is summarized and results are presented with the aim of providing a concise reference for those interested in addressing the topic in an introductory organic chemistry curriculum.
Chemistry of St. John's Wort: Hypericin and Hyperforin
ERIC Educational Resources Information Center
Vollmer, John J.; Rosenson, Jon
2004-01-01
The appeal as natural antidepressant is the major selling point of St. John's Wort, which is referred to as "Prozac from the plant kingdom". Hypericin and hyperforin, two major constituents with significant biological activity of St. John's Wort and which are complex molecules with unusual features, are examined.
Waste Treatment in the Undergraduate Laboratory: Let the Students Do It!
ERIC Educational Resources Information Center
Nash, John J.; And Others
1996-01-01
Presents the details of a waste treatment experiment that enables students to employ much of the chemistry they have learned in class to solve a real chemical problem. Heightens students' awareness of the potential environmental impact associated with the waste they have generated. Contains 21 references. (JRH)
Evaluation of Density Functionals and Basis Sets for Carbohydrates
USDA-ARS?s Scientific Manuscript database
Correlated ab initio wave function calculations using MP2/aug-cc-pVTZ model chemistry have been performed for three test sets of gas phase saccharide conformations to provide reference values for their relative energies. The test sets consist of 15 conformers of alpha and beta-D-allopyranose, 15 of ...
Learning the Collection: A New Librarian's Experience in Collection Management
ERIC Educational Resources Information Center
Lewin, Heather
2010-01-01
The author is a reference and instruction librarian at Iowa State University with collection development and liaison responsibilities for chemistry, biochemistry, entomology, and natural resource ecology. She recently came to librarianship with an education and three years' experience in biochemistry and biotechnology. During the last four years…
The supernova: A stellar spectacle
NASA Technical Reports Server (NTRS)
Straka, W. C.
1976-01-01
The life of a star, the supernova, related objects and their importance in astronomy and science in general are discussed. Written primarily for science teachers of secondary school chemistry, physics, and earth sciences, the booklet contains a glossary, reference sources, suggested topics for discussion, and projects for individual or group assignment.
Analysis of a Suspected Drug Sample
ERIC Educational Resources Information Center
Schurter, Eric J.; Zook-Gerdau, Lois Anne; Szalay, Paul
2011-01-01
This general chemistry laboratory uses differences in solubility to separate a mixture of caffeine and aspirin while introducing the instrumental analysis methods of GCMS and FTIR. The drug mixture is separated by partitioning aspirin and caffeine between dichloromethane and aqueous base. TLC and reference standards are used to identify aspirin…