Sample records for chest compression depth

  1. Characterization of Pediatric In-Hospital Cardiopulmonary Resuscitation Quality Metrics Across an International Resuscitation Collaborative.

    PubMed

    Niles, Dana E; Duval-Arnould, Jordan; Skellett, Sophie; Knight, Lynda; Su, Felice; Raymond, Tia T; Sweberg, Todd; Sen, Anita I; Atkins, Dianne L; Friess, Stuart H; de Caen, Allan R; Kurosawa, Hiroshi; Sutton, Robert M; Wolfe, Heather; Berg, Robert A; Silver, Annemarie; Hunt, Elizabeth A; Nadkarni, Vinay M

    2018-05-01

    Pediatric in-hospital cardiac arrest cardiopulmonary resuscitation quality metrics have been reported in few children less than 8 years. Our objective was to characterize chest compression fraction, rate, depth, and compliance with 2015 American Heart Association guidelines across multiple pediatric hospitals. Retrospective observational study of data from a multicenter resuscitation quality collaborative from October 2015 to April 2017. Twelve pediatric hospitals across United States, Canada, and Europe. In-hospital cardiac arrest patients (age < 18 yr) with quantitative cardiopulmonary resuscitation data recordings. None. There were 112 events yielding 2,046 evaluable 60-second epochs of cardiopulmonary resuscitation (196,669 chest compression). Event cardiopulmonary resuscitation metric summaries (median [interquartile range]) by age: less than 1 year (38/112): chest compression fraction 0.88 (0.61-0.98), chest compression rate 119/min (110-129), and chest compression depth 2.3 cm (1.9-3.0 cm); for 1 to less than 8 years (42/112): chest compression fraction 0.94 (0.79-1.00), chest compression rate 117/min (110-124), and chest compression depth 3.8 cm (2.9-4.6 cm); for 8 to less than 18 years (32/112): chest compression fraction 0.94 (0.85-1.00), chest compression rate 117/min (110-123), chest compression depth 5.5 cm (4.0-6.5 cm). "Compliance" with guideline targets for 60-second chest compression "epochs" was predefined: chest compression fraction greater than 0.80, chest compression rate 100-120/min, and chest compression depth: greater than or equal to 3.4 cm in less than 1 year, greater than or equal to 4.4 cm in 1 to less than 8 years, and 4.5 to less than 6.6 cm in 8 to less than 18 years. Proportion of less than 1 year, 1 to less than 8 years, and 8 to less than 18 years events with greater than or equal to 60% of 60-second epochs meeting compliance (respectively): chest compression fraction was 53%, 81%, and 78%; chest compression rate was 32%, 50%, and 63%; chest compression depth was 13%, 19%, and 44%. For all events combined, total compliance (meeting all three guideline targets) was 10% (11/112). Across an international pediatric resuscitation collaborative, we characterized the landscape of pediatric in-hospital cardiac arrest chest compression quality metrics and found that they often do not meet 2015 American Heart Association guidelines. Guideline compliance for rate and depth in children less than 18 years is poor, with the greatest difficulty in achieving chest compression depth targets in younger children.

  2. Induction of a shorter compression phase is correlated with a deeper chest compression during metronome-guided cardiopulmonary resuscitation: a manikin study.

    PubMed

    Chung, Tae Nyoung; Bae, Jinkun; Kim, Eui Chung; Cho, Yun Kyung; You, Je Sung; Choi, Sung Wook; Kim, Ok Jun

    2013-07-01

    Recent studies have shown that there may be an interaction between duty cycle and other factors related to the quality of chest compression. Duty cycle represents the fraction of compression phase. We aimed to investigate the effect of shorter compression phase on average chest compression depth during metronome-guided cardiopulmonary resuscitation. Senior medical students performed 12 sets of chest compressions following the guiding sounds, with three down-stroke patterns (normal, fast and very fast) and four rates (80, 100, 120 and 140 compressions/min) in random sequence. Repeated-measures analysis of variance was used to compare the average chest compression depth and duty cycle among the trials. The average chest compression depth increased and the duty cycle decreased in a linear fashion as the down-stroke pattern shifted from normal to very fast (p<0.001 for both). Linear increase of average chest compression depth following the increase of the rate of chest compression was observed only with normal down-stroke pattern (p=0.004). Induction of a shorter compression phase is correlated with a deeper chest compression during metronome-guided cardiopulmonary resuscitation.

  3. Instructions to "push as hard as you can" improve average chest compression depth in dispatcher-assisted cardiopulmonary resuscitation.

    PubMed

    Mirza, Muzna; Brown, Todd B; Saini, Devashish; Pepper, Tracy L; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S

    2008-10-01

    Cardiopulmonary resuscitation (CPR) with adequate chest compression depth appears to improve first shock success in cardiac arrest. We evaluate the effect of simplification of chest compression instructions on compression depth in dispatcher-assisted CPR protocol. Data from two randomized, double-blinded, controlled trials with identical methodology were combined to obtain 332 records for this analysis. Subjects were randomized to either modified Medical Priority Dispatch System (MPDS) v11.2 protocol or a new simplified protocol. The main difference between the protocols was the instruction to "push as hard as you can" in the simplified protocol, compared to "push down firmly 2in. (5cm)" in MPDS. Data were recorded via a Laerdal ResusciAnne SkillReporter manikin. Primary outcome measures included: chest compression depth, proportion of compressions without error, with adequate depth and with total release. Instructions to "push as hard as you can", compared to "push down firmly 2in. (5cm)", resulted in improved chest compression depth (36.4 mm vs. 29.7 mm, p<0.0001), and improved median proportion of chest compressions done to the correct depth (32% vs. <1%, p<0.0001). No significant difference in median proportion of compressions with total release (100% for both) and average compression rate (99.7 min(-1) vs. 97.5 min(-1), p<0.56) was found. Modifying dispatcher-assisted CPR instructions by changing "push down firmly 2in. (5cm)" to "push as hard as you can" achieved improvement in chest compression depth at no cost to total release or average chest compression rate.

  4. Resuscitation quality of rotating chest compression providers at one-minute vs. two-minute intervals: A mannequin study.

    PubMed

    Kılıç, D; Göksu, E; Kılıç, T; Buyurgan, C S

    2018-05-01

    The aim of this randomized cross-over study was to compare one-minute and two-minute continuous chest compressions in terms of chest compression only CPR quality metrics on a mannequin model in the ED. Thirty-six emergency medicine residents participated in this study. In the 1-minute group, there was no statistically significant difference in the mean compression rate (p=0.83), mean compression depth (p=0.61), good compressions (p=0.31), the percentage of complete release (p=0.07), adequate compression depth (p=0.11) or the percentage of good rate (p=51) over the four-minute time period. Only flow time was statistically significant among the 1-minute intervals (p<0.001). In the 2-minute group, the mean compression depth (p=0.19), good compression (p=0.92), the percentage of complete release (p=0.28), adequate compression depth (p=0.96), and the percentage of good rate (p=0.09) were not statistically significant over time. In this group, the number of compressions (248±31 vs 253±33, p=0.01) and mean compression rates (123±15 vs 126±17, p=0.01) and flow time (p=0.001) were statistically significant along the two-minute intervals. There was no statistically significant difference in the mean number of chest compressions per minute, mean chest compression depth, the percentage of good compressions, complete release, adequate chest compression depth and percentage of good compression between the 1-minute and 2-minute groups. There was no statistically significant difference in the quality metrics of chest compressions between 1- and 2-minute chest compression only groups. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Instructions to “push as hard as you can” improve average chest compression depth in dispatcher-assisted Cardiopulmonary Resuscitation

    PubMed Central

    Mirza, Muzna; Brown, Todd B.; Saini, Devashish; Pepper, Tracy L; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S.

    2008-01-01

    Background and Objective Cardiopulmonary Resuscitation (CPR) with adequate chest compression depth appears to improve first shock success in cardiac arrest. We evaluate the effect of simplification of chest compression instructions on compression depth in dispatcher-assisted CPR protocol. Methods Data from two randomized, double-blinded, controlled trials with identical methodology were combined to obtain 332 records for this analysis. Subjects were randomized to either modified Medical Priority Dispatch System (MPDS) v11.2 protocol or a new simplified protocol. The main difference between the protocols was the instruction to “push as hard as you can” in the simplified protocol, compared to “push down firmly 2 inches (5cm)” in MPDS. Data were recorded via a Laerdal® ResusciAnne® SkillReporter™ manikin. Primary outcome measures included: chest compression depth, proportion of compressions without error, with adequate depth and with total release. Results Instructions to “push as hard as you can”, compared to “push down firmly 2 inches (5cm)”, resulted in improved chest compression depth (36.4 vs 29.7 mm, p<0.0001), and improved median proportion of chest compressions done to the correct depth (32% vs <1%, p<0.0001). No significant difference in median proportion of compressions with total release (100% for both) and average compression rate (99.7 vs 97.5 per min, p<0.56) was found. Conclusions Modifying dispatcher-assisted CPR instructions by changing “push down firmly 2 inches (5cm)” to “push as hard as you can” achieved improvement in chest compression depth at no cost to total release or average chest compression rate. PMID:18635306

  6. A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation.

    PubMed

    Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Cho, Young Soon; Chung, Sung Phil; Park, Incheol

    2012-01-01

    Metronome guidance is a simple and economical feedback system for guiding cardiopulmonary resuscitation (CPR). However, a recent study showed that metronome guidance reduced the depth of chest compression. The results of previous studies suggest that a higher chest compression rate is associated with a better CPR outcome as compared with a lower chest compression rate, irrespective of metronome use. Based on this finding, we hypothesized that a lower chest compression rate promotes a reduction in chest compression depth in the recent study rather than metronome use itself. One minute of chest compression-only CPR was performed following the metronome sound played at 1 of 4 different rates: 80, 100, 120, and 140 ticks/min. Average compression depths (ACDs) and duty cycles were compared using repeated measures analysis of variance, and the values in the absence and presence of metronome guidance were compared. Both the ACD and duty cycle increased when the metronome rate increased (P = .017, <.001). Average compression depths for the CPR procedures following the metronome rates of 80 and 100 ticks/min were significantly lower than those for the procedures without metronome guidance. The ACD and duty cyle for chest compression increase as the metronome rate increases during metronome-guided CPR. A higher rate of chest compression is necessary for metronome-guided CPR to prevent suboptimal quality of chest compression. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Effect of the rate of chest compression familiarised in previous training on the depth of chest compression during metronome-guided cardiopulmonary resuscitation: a randomised crossover trial

    PubMed Central

    Bae, Jinkun; Chung, Tae Nyoung; Je, Sang Mo

    2016-01-01

    Objectives To assess how the quality of metronome-guided cardiopulmonary resuscitation (CPR) was affected by the chest compression rate familiarised by training before the performance and to determine a possible mechanism for any effect shown. Design Prospective crossover trial of a simulated, one-person, chest-compression-only CPR. Setting Participants were recruited from a medical school and two paramedic schools of South Korea. Participants 42 senior students of a medical school and two paramedic schools were enrolled but five dropped out due to physical restraints. Intervention Senior medical and paramedic students performed 1 min of metronome-guided CPR with chest compressions only at a speed of 120 compressions/min after training for chest compression with three different rates (100, 120 and 140 compressions/min). Friedman's test was used to compare average compression depths based on the different rates used during training. Results Average compression depths were significantly different according to the rate used in training (p<0.001). A post hoc analysis showed that average compression depths were significantly different between trials after training at a speed of 100 compressions/min and those at speeds of 120 and 140 compressions/min (both p<0.001). Conclusions The depth of chest compression during metronome-guided CPR is affected by the relative difference between the rate of metronome guidance and the chest compression rate practised in previous training. PMID:26873050

  8. Effect of the rate of chest compression familiarised in previous training on the depth of chest compression during metronome-guided cardiopulmonary resuscitation: a randomised crossover trial.

    PubMed

    Bae, Jinkun; Chung, Tae Nyoung; Je, Sang Mo

    2016-02-12

    To assess how the quality of metronome-guided cardiopulmonary resuscitation (CPR) was affected by the chest compression rate familiarised by training before the performance and to determine a possible mechanism for any effect shown. Prospective crossover trial of a simulated, one-person, chest-compression-only CPR. Participants were recruited from a medical school and two paramedic schools of South Korea. 42 senior students of a medical school and two paramedic schools were enrolled but five dropped out due to physical restraints. Senior medical and paramedic students performed 1 min of metronome-guided CPR with chest compressions only at a speed of 120 compressions/min after training for chest compression with three different rates (100, 120 and 140 compressions/min). Friedman's test was used to compare average compression depths based on the different rates used during training. Average compression depths were significantly different according to the rate used in training (p<0.001). A post hoc analysis showed that average compression depths were significantly different between trials after training at a speed of 100 compressions/min and those at speeds of 120 and 140 compressions/min (both p<0.001). The depth of chest compression during metronome-guided CPR is affected by the relative difference between the rate of metronome guidance and the chest compression rate practised in previous training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Influence of chest compression rate guidance on the quality of cardiopulmonary resuscitation performed on manikins.

    PubMed

    Jäntti, H; Silfvast, T; Turpeinen, A; Kiviniemi, V; Uusaro, A

    2009-04-01

    The adequate chest compression rate during CPR is associated with improved haemodynamics and primary survival. To explore whether the use of a metronome would affect also chest compression depth beside the rate, we evaluated CPR quality using a metronome in a simulated CPR scenario. Forty-four experienced intensive care unit nurses participated in two-rescuer basic life support given to manikins in 10min scenarios. The target chest compression to ventilation ratio was 30:2 performed with bag and mask ventilation. The rescuer performing the compressions was changed every 2min. CPR was performed first without and then with a metronome that beeped 100 times per minute. The quality of CPR was analysed with manikin software. The effect of rescuer fatigue on CPR quality was analysed separately. The mean compression rate between ventilation pauses was 137+/-18compressions per minute (cpm) without and 98+/-2cpm with metronome guidance (p<0.001). The mean number of chest compressions actually performed was 104+/-12cpm without and 79+/-3cpm with the metronome (p<0.001). The mean compression depth during the scenario was 46.9+/-7.7mm without and 43.2+/-6.3mm with metronome guidance (p=0.09). The total number of chest compressions performed was 1022 without metronome guidance, 42% at the correct depth; and 780 with metronome guidance, 61% at the correct depth (p=0.09 for difference for percentage of compression with correct depth). Metronome guidance corrected chest compression rates for each compression cycle to within guideline recommendations, but did not affect chest compression quality or rescuer fatigue.

  10. Chest compression rates and survival following out-of-hospital cardiac arrest.

    PubMed

    Idris, Ahamed H; Guffey, Danielle; Pepe, Paul E; Brown, Siobhan P; Brooks, Steven C; Callaway, Clifton W; Christenson, Jim; Davis, Daniel P; Daya, Mohamud R; Gray, Randal; Kudenchuk, Peter J; Larsen, Jonathan; Lin, Steve; Menegazzi, James J; Sheehan, Kellie; Sopko, George; Stiell, Ian; Nichol, Graham; Aufderheide, Tom P

    2015-04-01

    Guidelines for cardiopulmonary resuscitation recommend a chest compression rate of at least 100 compressions/min. A recent clinical study reported optimal return of spontaneous circulation with rates between 100 and 120/min during cardiopulmonary resuscitation for out-of-hospital cardiac arrest. However, the relationship between compression rate and survival is still undetermined. Prospective, observational study. Data is from the Resuscitation Outcomes Consortium Prehospital Resuscitation IMpedance threshold device and Early versus Delayed analysis clinical trial. Adults with out-of-hospital cardiac arrest treated by emergency medical service providers. None. Data were abstracted from monitor-defibrillator recordings for the first five minutes of emergency medical service cardiopulmonary resuscitation. Multiple logistic regression assessed odds ratio for survival by compression rate categories (<80, 80-99, 100-119, 120-139, ≥140), both unadjusted and adjusted for sex, age, witnessed status, attempted bystander cardiopulmonary resuscitation, location of arrest, chest compression fraction and depth, first rhythm, and study site. Compression rate data were available for 10,371 patients; 6,399 also had chest compression fraction and depth data. Age (mean±SD) was 67±16 years. Chest compression rate was 111±19 per minute, compression fraction was 0.70±0.17, and compression depth was 42±12 mm. Circulation was restored in 34%; 9% survived to hospital discharge. After adjustment for covariates without chest compression depth and fraction (n=10,371), a global test found no significant relationship between compression rate and survival (p=0.19). However, after adjustment for covariates including chest compression depth and fraction (n=6,399), the global test found a significant relationship between compression rate and survival (p=0.02), with the reference group (100-119 compressions/min) having the greatest likelihood for survival. After adjustment for chest compression fraction and depth, compression rates between 100 and 120 per minute were associated with greatest survival to hospital discharge.

  11. Application of current guidelines for chest compression depth on different surfaces and using feedback devices: a randomized cross-over study.

    PubMed

    Schober, P; Krage, R; Lagerburg, V; Van Groeningen, D; Loer, S A; Schwarte, L A

    2014-04-01

    Current cardiopulmonary resuscitation (CPR)-guidelines recommend an increased chest compression depth and rate compared to previous guidelines, and the use of automatic feedback devices is encouraged. However, it is unclear whether this compression depth can be maintained at an increased frequency. Moreover, the underlying surface may influence accuracy of feedback devices. We investigated compression depths over time and evaluated the accuracy of a feedback device on different surfaces. Twenty-four volunteers performed four two-minute blocks of CPR targeting at current guideline recommendations on different surfaces (floor, mattress, 2 backboards) on a patient simulator. Participants rested for 2 minutes between blocks. Influences of time and different surfaces on chest compression depth (ANOVA, mean [95% CI]) and accuracy of a feedback device to determine compression depth (Bland-Altman) were assessed. Mean compression depth did not reach recommended depth and decreased over time during all blocks (first block: from 42 mm [39-46 mm] to 39 mm [37-42 mm]). A two-minute resting period was insufficient to restore compression depth to baseline. No differences in compression depth were observed on different surfaces. The feedback device slightly underestimated compression depth on the floor (bias -3.9 mm), but markedly overestimated on the mattress (bias +12.6 mm). This overestimation was eliminated after correcting compression depth by a second sensor between manikin and mattress. Strategies are needed to improve chest compression depth, and more than two providers should alternate with chest compressions. The underlying surface does not necessarily adversely affect CPR performance but influences accuracy of feedback devices. Accuracy is improved by a second, posterior, sensor.

  12. Adequate performance of cardiopulmonary resuscitation techniques during simulated cardiac arrest over and under protective equipment in football.

    PubMed

    Waninger, Kevin N; Goodbred, Andrew; Vanic, Keith; Hauth, John; Onia, Joshua; Stoltzfus, Jill; Melanson, Scott

    2014-07-01

    To investigate (1) cardiopulmonary resuscitation (CPR) adequacy during simulated cardiac arrest of equipped football players and (2) whether protective football equipment impedes CPR performance measures. Exploratory crossover study performed on Laerdal SimMan 3 G interactive manikin simulator. Temple University/St Luke's University Health Network Regional Medical School Simulation Laboratory. Thirty BCLS-certified ATCs and 6 ACLS-certified emergency department technicians. Subjects were given standardized rescuer scenarios to perform three 2-minute sequences of compression-only CPR. Baseline CPR sequences were captured on each subject. Experimental conditions included 2-minute sequences of CPR either over protective football shoulder pads or under unlaced pads. Subjects were instructed to adhere to 2010 American Heart Association guidelines (initiation of compressions alone at 100/min to 51 mm). Dependent variables included average compression depth, average compression rate, percentage of time chest wall recoiled, and percentage of hands-on contact during compressions. Differences between subject groups were not found to be statistically significant, so groups were combined (n = 36) for analysis of CPR compression adequacy. Compression depth was deeper under shoulder pads than over (P = 0.02), with mean depths of 36.50 and 31.50 mm, respectively. No significant difference was found with compression rate or chest wall recoil. Chest compression depth is significantly decreased when performed over shoulder pads, while there is no apparent effect on rate or chest wall recoil. Although the clinical outcomes from our observed 15% difference in compression depth are uncertain, chest compression under the pads significantly increases the depth of compressions and more closely approaches American Heart Association guidelines for chest compression depth in cardiac arrest.

  13. Transthoracic impedance for the monitoring of quality of manual chest compression during cardiopulmonary resuscitation.

    PubMed

    Zhang, Hehua; Yang, Zhengfei; Huang, Zitong; Chen, Bihua; Zhang, Lei; Li, Heng; Wu, Baoming; Yu, Tao; Li, Yongqin

    2012-10-01

    The quality of cardiopulmonary resuscitation (CPR), especially adequate compression depth, is associated with return of spontaneous circulation (ROSC) and is therefore recommended to be measured routinely. In the current study, we investigated the relationship between changes of transthoracic impedance (TTI) measured through the defibrillation electrodes, chest compression depth and coronary perfusion pressure (CPP) in a porcine model of cardiac arrest. In 14 male pigs weighing between 28 and 34 kg, ventricular fibrillation (VF) was electrically induced and untreated for 6 min. Animals were randomized to either optimal or suboptimal chest compression group. Optimal depth of manual compression in 7 pigs was defined as a decrease of 25% (50 mm) in anterior posterior diameter of the chest, while suboptimal compression was defined as 70% of the optimal depth (35 mm). After 2 min of chest compression, defibrillation was attempted with a 120-J rectilinear biphasic shock. There were no differences in baseline measurements between groups. All animals had ROSC after optimal compressions; this contrasted with suboptimal compressions, after which only 2 of the animals had ROSC (100% vs. 28.57%, p=0.021). The correlation coefficient was 0.89 between TTI amplitude and compression depth (p<0.001), 0.83 between TTI amplitude and CPP (p<0.001). Amplitude change of TTI was correlated with compression depth and CPP in this porcine model of cardiac arrest. The TTI measured from defibrillator electrodes, therefore has the potential to serve as an indicator to monitor the quality of chest compression and estimate CPP during CPR. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. A Novel Method of Newborn Chest Compression: A Randomized Crossover Simulation Study.

    PubMed

    Smereka, Jacek; Szarpak, Lukasz; Ladny, Jerzy R; Rodriguez-Nunez, Antonio; Ruetzler, Kurt

    2018-01-01

    Objective: To compare a novel two-thumb chest compression technique with standard techniques during newborn resuscitation performed by novice physicians in terms of median depth of chest compressions, degree of full chest recoil, and effective compression efficacy. Patients and Methods: The total of 74 novice physicians with less than 1-year work experience participated in the study. They performed chest compressions using three techniques: (A) The new two-thumb technique (nTTT). The novel method of chest compressions in an infant consists in using two thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist. (B) TFT. With this method, the rescuer compresses the sternum with the tips of two fingers. (C) TTHT. Two thumbs are placed over the lower third of the sternum, with the fingers encircling the torso and supporting the back. Results: The median depth of chest compressions for nTTT was 3.8 (IQR, 3.7-3.9) cm, for TFT-2.1 (IQR, 1.7-2.5) cm, while for TTHT-3.6 (IQR, 3.5-3.8) cm. There was a significant difference between nTTT and TFT, and TTHT and TFT ( p < 0.001) for each time interval during resuscitation. The degree of full chest recoil was 93% (IQR, 91-97) for nTTT, 99% (IQR, 96-100) for TFT, and 90% (IQR, 74-91) for TTHT. There was a statistically significant difference in the degree of complete chest relaxation between nTTT and TFT ( p < 0.001), between nTTT and TTHT ( p = 0.016), and between TFT and TTHT ( p < 0.001). Conclusion: The median chest compression depth for nTTT and TTHT is significantly higher than that for TFT. The degree of full chest recoil was highest for TFT, then for nTTT and TTHT. The effective compression efficiency with nTTT was higher than for TTHT and TFT. Our novel newborn chest compression method in this manikin study provided adequate chest compression depth and degree of full chest recoil, as well as very good effective compression efficiency. Further clinical studies are necessary to confirm these initial results.

  15. Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers

    PubMed Central

    Ruiz de Gauna, Sofía; González-Otero, Digna M.; Ruiz, Jesus; Russell, James K.

    2016-01-01

    Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer’s hands and the manikin’s chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8–10.3), 6.3% (2.9–11.3), and 2.5% (1.2–4.4) for depth and 1.7% (0.0–2.3), 0.0% (0.0–2.0), and 0.9% (0.4–1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data. PMID:26930061

  16. A Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis

    PubMed Central

    Gutiérrez, J. J.; Russell, James K.

    2016-01-01

    Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin's back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%). Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p < 0.001). Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p < 0.001). Median error in rate was 0.9 cpm (1.0%), with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces. PMID:27999808

  17. The effect of hydraulic bed movement on the quality of chest compressions.

    PubMed

    Park, Maeng Real; Lee, Dae Sup; In Kim, Yong; Ryu, Ji Ho; Cho, Young Mo; Kim, Hyung Bin; Yeom, Seok Ran; Min, Mun Ki

    2017-08-01

    The hydraulic height control systems of hospital beds provide convenience and shock absorption. However, movements in a hydraulic bed may reduce the effectiveness of chest compressions. This study investigated the effects of hydraulic bed movement on chest compressions. Twenty-eight participants were recruited for this study. All participants performed chest compressions for 2min on a manikin and three surfaces: the floor (Day 1), a firm plywood bed (Day 2), and a hydraulic bed (Day 3). We considered 28 participants of Day 1 as control and each 28 participants of Day 2 and Day 3 as study subjects. The compression rates, depths, and good compression ratios (>5-cm compressions/all compressions) were compared between the three surfaces. When we compared the three surfaces, we did not detect a significant difference in the speed of chest compressions (p=0.582). However, significantly lower values were observed on the hydraulic bed in terms of compression depth (p=0.001) and the good compression ratio (p=0.003) compared to floor compressions. When we compared the plywood and hydraulic beds, we did not detect significant differences in compression depth (p=0.351) and the good compression ratio (p=0.391). These results indicate that the movements in our hydraulic bed were associated with a non-statistically significant trend towards lower-quality chest compressions. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A simple accurate chest-compression depth gauge using magnetic coils during cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Kandori, Akihiko; Sano, Yuko; Zhang, Yuhua; Tsuji, Toshio

    2015-12-01

    This paper describes a new method for calculating chest compression depth and a simple chest-compression gauge for validating the accuracy of the method. The chest-compression gauge has two plates incorporating two magnetic coils, a spring, and an accelerometer. The coils are located at both ends of the spring, and the accelerometer is set on the bottom plate. Waveforms obtained using the magnetic coils (hereafter, "magnetic waveforms"), which are proportional to compression-force waveforms and the acceleration waveforms were measured at the same time. The weight factor expressing the relationship between the second derivatives of the magnetic waveforms and the measured acceleration waveforms was calculated. An estimated-compression-displacement (depth) waveform was obtained by multiplying the weight factor and the magnetic waveforms. Displacements of two large springs (with similar spring constants) within a thorax and displacements of a cardiopulmonary resuscitation training manikin were measured using the gauge to validate the accuracy of the calculated waveform. A laser-displacement detection system was used to compare the real displacement waveform and the estimated waveform. Intraclass correlation coefficients (ICCs) between the real displacement using the laser system and the estimated displacement waveforms were calculated. The estimated displacement error of the compression depth was within 2 mm (<1 standard deviation). All ICCs (two springs and a manikin) were above 0.85 (0.99 in the case of one of the springs). The developed simple chest-compression gauge, based on a new calculation method, provides an accurate compression depth (estimation error < 2 mm).

  19. Real-time feedback can improve infant manikin cardiopulmonary resuscitation by up to 79%--a randomised controlled trial.

    PubMed

    Martin, Philip; Theobald, Peter; Kemp, Alison; Maguire, Sabine; Maconochie, Ian; Jones, Michael

    2013-08-01

    European and Advanced Paediatric Life Support training courses. Sixty-nine certified CPR providers. CPR providers were randomly allocated to a 'no-feedback' or 'feedback' group, performing two-thumb and two-finger chest compressions on a "physiological", instrumented resuscitation manikin. Baseline data was recorded without feedback, before chest compressions were repeated with one group receiving feedback. Indices were calculated that defined chest compression quality, based upon comparison of the chest wall displacement to the targets of four, internationally recommended parameters: chest compression depth, release force, chest compression rate and compression duty cycle. Baseline data were consistent with other studies, with <1% of chest compressions performed by providers simultaneously achieving the target of the four internationally recommended parameters. During the 'experimental' phase, 34 CPR providers benefitted from the provision of 'real-time' feedback which, on analysis, coincided with a statistical improvement in compression rate, depth and duty cycle quality across both compression techniques (all measures: p<0.001). Feedback enabled providers to simultaneously achieve the four targets in 75% (two-finger) and 80% (two-thumb) of chest compressions. Real-time feedback produced a dramatic increase in the quality of chest compression (i.e. from <1% to 75-80%). If these results transfer to a clinical scenario this technology could, for the first time, support providers in consistently performing accurate chest compressions during infant CPR and thus potentially improving clinical outcomes. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. An investigation of thrust, depth and the impedance cardiogram as measures of cardiopulmonary resuscitation efficacy in a porcine model of cardiac arrest.

    PubMed

    Howe, Andrew; O'Hare, Peter; Crawford, Paul; Delafont, Bruno; McAlister, Olibhear; Di Maio, Rebecca; Clutton, Eddie; Adgey, Jennifer; McEneaney, David

    2015-11-01

    Optimising the depth and rate of applied chest compressions following out of hospital cardiac arrest is crucial in maintaining end organ perfusion and improving survival. The impedance cardiogram (ICG) measured via defibrillator pads produces a characteristic waveform during chest compressions with the potential to provide feedback on cardiopulmonary resuscitation (CPR) and enhance performance. The objective of this pre-clinical study was to investigate the relationship between mechanical and physiological markers of CPR efficacy in a porcine model and examine the strength of correlation between the ICG amplitude, compression depth and end-tidal CO2 (ETCO2). Two experiments were performed using 24 swine (12 per experiment). For experiment 1, ventricular fibrillation (VF) was induced and mechanical CPR commenced at varying thrusts (0-60 kg) for 2 min intervals. Chest compression depth was recorded using a Philips QCPR device with additional recording of invasive physiological parameters: systolic blood pressure, ETCO2, cardiac output and carotid flow. For experiment 2, VF was induced and mechanical CPR commenced at varying depths (0-5 cm) for 2 min intervals. The ICG was recorded via defibrillator pads attached to the animal's sternum and connected to a Heartsine 500 P defibrillator. ICG amplitude, chest compression depth, systolic blood pressure and ETCO2 were recorded during each cycle. In both experiments the within-animal correlation between the measured parameters was assessed using a mixed effect model. In experiment 1 moderate within-animal correlations were observed between physiological parameters and compression depth (r=0.69-0.77) and thrust (r=0.66-0.82). A moderate correlation was observed between compression depth and thrust (r=0.75). In experiment 2 a strong within-animal correlation and moderate overall correlations were observed between ICG amplitude and compression depth (r=0.89, r=0.79) and ETCO2 (r=0.85, r=0.64). In this porcine model of induced cardiac arrest moderate within animal correlations were observed between mechanical and physiological markers of chest compression efficacy demonstrating the challenge in utilising a single mechanical metric to quantify chest compression efficacy. ICG amplitude demonstrated strong within animal correlations with compression depth and ETCO2 suggesting its potential utility to provide CPR feedback in the out of hospital setting to improve performance. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Evaluation of a newly developed infant chest compression technique

    PubMed Central

    Smereka, Jacek; Bielski, Karol; Ladny, Jerzy R.; Ruetzler, Kurt; Szarpak, Lukasz

    2017-01-01

    Abstract Background: Providing adequate chest compression is essential during infant cardio-pulmonary-resuscitation (CPR) but was reported to be performed poor. The “new 2-thumb technique” (nTTT), which consists in using 2 thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist, was recently introduced. Therefore, the aim of this study was to compare 3 chest compression techniques, namely, the 2-finger-technique (TFT), the 2-thumb-technique (TTHT), and the nTTT in an randomized infant-CPR manikin setting. Methods: A total of 73 paramedics with at least 1 year of clinical experience performed 3 CPR settings with a chest compression:ventilation ratio of 15:2, according to current guidelines. Chest compression was performed with 1 out of the 3 chest compression techniques in a randomized sequence. Chest compression rate and depth, chest decompression, and adequate ventilation after chest compression served as outcome parameters. Results: The chest compression depth was 29 (IQR, 28–29) mm in the TFT group, 42 (40–43) mm in the TTHT group, and 40 (39–40) mm in the nTTT group (TFT vs TTHT, P < 0.001; TFT vs nTTT, P < 0.001; TTHT vs nTTT, P < 0.01). The median compression rate with TFT, TTHT, and nTTT varied and amounted to 136 (IQR, 133–144) min–1 versus 117 (115–121) min–1 versus 111 (109–113) min–1. There was a statistically significant difference in the compression rate between TFT and TTHT (P < 0.001), TFT and nTTT (P < 0.001), as well as TTHT and nTTT (P < 0.001). Incorrect decompressions after CC were significantly increased in the TTHT group compared with the TFT (P < 0.001) and the nTTT (P < 0.001) group. Conclusions: The nTTT provides adequate chest compression depth and rate and was associated with adequate chest decompression and possibility to adequately ventilate the infant manikin. Further clinical studies are necessary to confirm these initial findings. PMID:28383397

  2. Evaluation of a newly developed infant chest compression technique: A randomized crossover manikin trial.

    PubMed

    Smereka, Jacek; Bielski, Karol; Ladny, Jerzy R; Ruetzler, Kurt; Szarpak, Lukasz

    2017-04-01

    Providing adequate chest compression is essential during infant cardio-pulmonary-resuscitation (CPR) but was reported to be performed poor. The "new 2-thumb technique" (nTTT), which consists in using 2 thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist, was recently introduced. Therefore, the aim of this study was to compare 3 chest compression techniques, namely, the 2-finger-technique (TFT), the 2-thumb-technique (TTHT), and the nTTT in an randomized infant-CPR manikin setting. A total of 73 paramedics with at least 1 year of clinical experience performed 3 CPR settings with a chest compression:ventilation ratio of 15:2, according to current guidelines. Chest compression was performed with 1 out of the 3 chest compression techniques in a randomized sequence. Chest compression rate and depth, chest decompression, and adequate ventilation after chest compression served as outcome parameters. The chest compression depth was 29 (IQR, 28-29) mm in the TFT group, 42 (40-43) mm in the TTHT group, and 40 (39-40) mm in the nTTT group (TFT vs TTHT, P < 0.001; TFT vs nTTT, P < 0.001; TTHT vs nTTT, P < 0.01). The median compression rate with TFT, TTHT, and nTTT varied and amounted to 136 (IQR, 133-144) min versus 117 (115-121) min versus 111 (109-113) min. There was a statistically significant difference in the compression rate between TFT and TTHT (P < 0.001), TFT and nTTT (P < 0.001), as well as TTHT and nTTT (P < 0.001). Incorrect decompressions after CC were significantly increased in the TTHT group compared with the TFT (P < 0.001) and the nTTT (P < 0.001) group. The nTTT provides adequate chest compression depth and rate and was associated with adequate chest decompression and possibility to adequately ventilate the infant manikin. Further clinical studies are necessary to confirm these initial findings.

  3. Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR.

    PubMed

    Park, Sang-Sub

    2014-01-01

    The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).

  4. A randomised control trial of prompt and feedback devices and their impact on quality of chest compressions--a simulation study.

    PubMed

    Yeung, Joyce; Davies, Robin; Gao, Fang; Perkins, Gavin D

    2014-04-01

    This study aims to compare the effect of three CPR prompt and feedback devices on quality of chest compressions amongst healthcare providers. A single blinded, randomised controlled trial compared a pressure sensor/metronome device (CPREzy), an accelerometer device (Phillips Q-CPR) and simple metronome on the quality of chest compressions on a manikin by trained rescuers. The primary outcome was compression depth. Secondary outcomes were compression rate, proportion of chest compressions with inadequate depth, incomplete release and user satisfaction. The pressure sensor device improved compression depth (37.24-43.64 mm, p=0.02), the accelerometer device decreased chest compression depth (37.38-33.19 mm, p=0.04) whilst the metronome had no effect (39.88 mm vs. 40.64 mm, p=0.802). Compression rate fell with all devices (pressure sensor device 114.68-98.84 min(-1), p=0.001, accelerometer 112.04-102.92 min(-1), p=0.072 and metronome 108.24 min(-1) vs. 99.36 min(-1), p=0.009). The pressure sensor feedback device reduced the proportion of compressions with inadequate depth (0.52 vs. 0.24, p=0.013) whilst the accelerometer device and metronome did not have a statistically significant effect. Incomplete release of compressions was common, but unaffected by the CPR feedback devices. Users preferred the accelerometer and metronome devices over the pressure sensor device. A post hoc study showed that de-activating the voice prompt on the accelerometer device prevented the deterioration in compression quality seen in the main study. CPR feedback devices vary in their ability to improve performance. In this study the pressure sensor device improved compression depth, whilst the accelerometer device reduced it and metronome had no effect. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Compressing with dominant hand improves quality of manual chest compressions for rescuers who performed suboptimal CPR in manikins.

    PubMed

    Wang, Juan; Tang, Ce; Zhang, Lei; Gong, Yushun; Yin, Changlin; Li, Yongqin

    2015-07-01

    The question of whether the placement of the dominant hand against the sternum could improve the quality of manual chest compressions remains controversial. In the present study, we evaluated the influence of dominant vs nondominant hand positioning on the quality of conventional cardiopulmonary resuscitation (CPR) during prolonged basic life support (BLS) by rescuers who performed optimal and suboptimal compressions. Six months after completing a standard BLS training course, 101 medical students were instructed to perform adult single-rescuer BLS for 8 minutes on a manikin with a randomized hand position. Twenty-four hours later, the students placed the opposite hand in contact with the sternum while performing CPR. Those with an average compression depth of less than 50 mm were considered suboptimal. Participants who had performed suboptimal compressions were significantly shorter (170.2 ± 6.8 vs 174.0 ± 5.6 cm, P = .008) and lighter (58.9 ± 7.6 vs 66.9 ± 9.6 kg, P < .001) than those who performed optimal compressions. No significant differences in CPR quality were observed between dominant and nondominant hand placements for these who had an average compression depth of greater than 50 mm. However, both the compression depth (49.7 ± 4.2 vs 46.5 ± 4.1 mm, P = .003) and proportion of chest compressions with an appropriate depth (47.6% ± 27.8% vs 28.0% ± 23.4%, P = .006) were remarkably higher when compressing the chest with the dominant hand against the sternum for those who performed suboptimal CPR. Chest compression quality significantly improved when the dominant hand was placed against the sternum for those who performed suboptimal compressions during conventional CPR. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Relationship between weight of rescuer and quality of chest compression during cardiopulmonary resuscitation

    PubMed Central

    2014-01-01

    Background According to the guidelines for cardiopulmonary resuscitation (CPR), the rotation time for chest compression should be about 2 min. The quality of chest compressions is related to the physical fitness of the rescuer, but this was not considered when determining rotation time. The present study aimed to clarify associations between body weight and the quality of chest compression and physical fatigue during CPR performed by 18 registered nurses (10 male and 8 female) assigned to light and heavy groups according to the average weight for each sex in Japan. Methods Five-minute chest compressions were then performed on a manikin that was placed on the floor. Measurement parameters were compression depth, heart rate, oxygen uptake, integrated electromyography signals, and rating of perceived exertion. Compression depth was evaluated according to the ratio (%) of adequate compressions (at least 5 cm deep). Results The ratio of adequate compressions decreased significantly over time in the light group. Values for heart rate, oxygen uptake, muscle activity defined as integrated electromyography signals, and rating of perceived exertion were significantly higher for the light group than for the heavy group. Conclusion Chest compression caused increased fatigue among the light group, which consequently resulted in a gradual fall in the quality of chest compression. These results suggested that individuals with a lower body weight should rotate at 1-min intervals to maintain high quality CPR and thus improve the survival rates and neurological outcomes of victims of cardiac arrest. PMID:24957919

  7. A Comparison of Chest Compression Quality Delivered During On-Scene and Ground Transport Cardiopulmonary Resuscitation

    PubMed Central

    Russi, Christopher S.; Myers, Lucas A.; Kolb, Logan J.; Lohse, Christine M.; Hess, Erik P.; White, Roger D.

    2016-01-01

    Introduction American Heart Association (AHA) guidelines recommend cardiopulmonary resuscitation (CPR) chest compressions 1.5 to 2 inches (3.75–5 cm) deep at 100 to 120 per minute. Recent studies demonstrated that manual CPR by emergency medical services (EMS) personnel is substandard. We hypothesized that transport CPR quality is significantly worse than on-scene CPR quality. Methods We analyzed adult patients receiving on-scene and transport chest compressions from nine EMS sites across Minnesota and Wisconsin from May 2008 to July 2010. Two periods were analyzed: before and after visual feedback. CPR data were collected and exported with the Zoll M series monitor and a sternally placed accelerometer measuring chest compression rate and depth. We compared compression data with 2010 AHA guidelines and Zoll RescueNet Code Review software. CPR depth and rate were “above (deep),” “in,” or “below (shallow)” the target range according to AHA guidelines. We paired on-scene and transport data for each patient; paired proportions were compared with the nonparametric Wilcoxon signed rank test. Results In the pre-feedback period, we analyzed 105 of 140 paired cases (75.0%); in the post-feedback period, 35 of 140 paired cases (25.0%) were analyzed. The proportion of correct depths during on-scene compressions (median, 41.9%; interquartile range [IQR], 16.1–73.1) was higher compared to the paired transport proportion (median, 8.7%; IQR, 2.7–48.9). Proportions of on-scene median correct rates and transport median correct depths did not improve in the post-feedback period. Conclusion Transport chest compressions are significantly worse than on-scene compressions. Implementation of visual real-time feedback did not affect performance. PMID:27625733

  8. Impact of a feedback device on chest compression quality during extended manikin CPR: a randomized crossover study.

    PubMed

    Buléon, Clément; Delaunay, Julie; Parienti, Jean-Jacques; Halbout, Laurent; Arrot, Xavier; Gérard, Jean-Louis; Hanouz, Jean-Luc

    2016-09-01

    Chest compressions require physical effort leading to increased fatigue and rapid degradation in the quality of cardiopulmonary resuscitation overtime. Despite harmful effect of interrupting chest compressions, current guidelines recommend that rescuers switch every 2 minutes. The impact on the quality of chest compressions during extended cardiopulmonary resuscitation has yet to be assessed. We conducted randomized crossover study on manikin (ResusciAnne; Laerdal). After randomization, 60 professional emergency rescuers performed 2 × 10 minutes of continuous chest compressions with and without a feedback device (CPRmeter). Efficient compression rate (primary outcome) was defined as the frequency target reached along with depth and leaning at the same time (recorded continuously). The 10-minute mean efficient compression rate was significantly better in the feedback group: 42% vs 21% (P< .001). There was no significant difference between the first (43%) and the tenth minute (36%; P= .068) with feedback. Conversely, a significant difference was evident from the second minute without feedback (35% initially vs 27%; P< .001). The efficient compression rate difference with and without feedback was significant every minute, from the second minute onwards. CPRmeter feedback significantly improved chest compression depth from the first minute, leaning from the second minute and rate from the third minute. A real-time feedback device delivers longer effective, steadier chest compressions over time. An extrapolation of these results from simulation may allow rescuer switches to be carried out beyond the currently recommended 2 minutes when a feedback device is used. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. The uniform chest compression depth of 50 mm or greater recommended by current guidelines is not appropriate for all adults.

    PubMed

    Lee, Soo Hoon; Kim, Dong Hoon; Kang, Tae-Sin; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kim, Dong Seob

    2015-08-01

    This study was conducted to evaluate the appropriateness of the chest compression (CC) depth recommended in the current guidelines and simulated external CCs, and to characterize the optimal CC depth for an adult by body mass index (BMI). Adult patients who underwent chest computed tomography as a screening test for latent pulmonary diseases in the health care center were enrolled in this study. We calculated the internal anteroposterior (AP) diameter (IAPD) and external AP diameter (EAPD) of the chest across BMIs (<18.50, 18.50-24.99, 25.00-29.99, and ≥30.00 kg/m(2)) for simulated CC depth. We also calculated the residual chest depths less than 20 mm for simulated CC depth. There was a statistically significant difference in the chest EAPD and IAPD measured at the lower half of the sternum for each BMI groups (EAPD: R(2) = 0.638, P < .001; IAPD: R(2) = 0.297, P < .001). For one-half external AP CC, 100% of the patients, regardless of BMI, had a calculated residual internal chest depth less than 20 mm. For one-fourth external AP CC, no patients had a calculated residual internal chest depth less than 20 mm. For one-third external AP CC, only 6.48% of the patients had a calculated residual internal chest depth less than 20 mm. It is not appropriate that the current CC depth (≥50 mm), expressed only as absolute measurement without a fraction of the depth of the chest, is applied uniformly in all adults. In addition, in terms of safety and efficacy, simulated CC targeting approximately between one-third and one-fourth EAPD CC depth might be appropriate. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Effectiveness and feasibility of assistant push on improvement of chest compression quality: a crossover study.

    PubMed

    Choi, Sung Soo; Yun, Seong-Woo; Lee, Byung Kook; Jeung, Kyung Woon; Song, Kyoung Hwan; Lee, Chang-Hee; Park, Jung Soo; Jeong, Ji Yeon; Shin, Sang Yeol

    2015-03-01

    To improve the quality of chest compression (CC), we developed the assistant-push method, whereby the second rescuer pushes the back of the chest compressor during CC. We investigated the effectiveness and feasibility of assistant push in achieving and maintaining the CC quality. This was a randomized crossover trial in which 41 subjects randomly performed both of standard CC (single-rescuer group) and CC with instructor-driven assistant push (assistant-push group) in different order. Each session of CC was performed for 2 minutes using a manikin. Subjects were also assigned to both roles of chest compressor and assistant and together performed CC with subject-driven assistant push. Depth of CC, compression to recoil ratio, duty cycle, and rate of incomplete recoil were quantified. The mean depth of CC (57.0 [56.0-59.0] vs 55.0 [49.5-57.5], P < .001) was significantly deeper, and the compression force (33.8 [29.3-36.4] vs 23.3 [20.4-25.3], P < .001) was stronger in the assistant-push group. The ratio of compression to recoil, duty cycle, and rate of incomplete chest recoil were comparable between the 2 groups. The CC depth in the single-rescuer group decreased significantly every 30 seconds, whereas in the assistant-push group, it was comparable at 60- and 90-second time points (P = .004). The subject assistant-push group performed CCs at a depth comparable with that of the instructor assistant-push group. The assistant-push method improved the depth of CC and attenuated its decline, eventually helping maintain adequate CC depth over time. Subjects were able to feasibly learn assistant push and performed effectively. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Quality of Basic Life Support - A Comparison between Medical Students and Paramedics.

    PubMed

    Körber, Maria Isabel; Köhler, Thomas; Weiss, Verena; Pfister, Roman; Michels, Guido

    2016-07-01

    Poor survival rates after cardiac arrest can partly be explained by poor basic life support skills in medical professionals. This study aimed to assess quality of basic life support in medical students and paramedics. We conducted a prospective observational study with 100 early medical students (group A), 100 late medical students (group B) and 100 paramedics (group C), performing a 20-minute basic life support simulation in teams of two. Average frequency and absolute number of chest compressions per minute (mean (±SD)), chest decompression (millimetres of compression remaining, mean (±SD)), hands-off-time (seconds/minute, mean (±SD)), frequency of switching positions between ventilation and chest compression (per 20 minutes) and rate of sufficient compressions (depth ≥50mm) were assessed as quality parameters of CPR. In groups A, B and C the rates of sufficiently deep chest compressions were 56%, 42% and 52%, respectively, without significant differences. Male gender and real-life CPR experience were significantly associated with deeper chest compression. Frequency and number of chest compressions were within recommended goals in at least 96% of all groups. Remaining chest compressions were 6 mm (±2), 6 mm (±2) and 5 mm (±2) with a significant difference between group A and C (p=0.017). Hands-off times were 6s/min (±1), 5s/min (±1) and 4s/min (±1), which was significantly different across all three groups. Overall, paramedics tended to show better quality of CPR compared to medical students. Though, chest compression depth as an important quality characteristic of CPR was insufficient in almost 50% of participants, even in well trained paramedics. Therefore, we suggest that an effort should be made to find better ways to educate health care professionals in BLS.

  12. Hemodynamic directed cardiopulmonary resuscitation improves short-term survival from ventricular fibrillation cardiac arrest.

    PubMed

    Friess, Stuart H; Sutton, Robert M; Bhalala, Utpal; Maltese, Matthew R; Naim, Maryam Y; Bratinov, George; Weiland, Theodore R; Garuccio, Mia; Nadkarni, Vinay M; Becker, Lance B; Berg, Robert A

    2013-12-01

    During cardiopulmonary resuscitation, adequate coronary perfusion pressure is essential for establishing return of spontaneous circulation. Current American Heart Association guidelines recommend standardized interval administration of epinephrine for patients in cardiac arrest. The objective of this study was to compare short-term survival using a hemodynamic directed resuscitation strategy versus chest compression depth-directed cardiopulmonary resuscitation in a porcine model of cardiac arrest. Randomized interventional study. Preclinical animal laboratory. Twenty-four 3-month-old female swine. After 7 minutes of ventricular fibrillation, pigs were randomized to receive one of three resuscitation strategies: 1) Hemodynamic directed care (coronary perfusion pressure-20): chest compressions with depth titrated to a target systolic blood pressure of 100 mm Hg and titration of vasopressors to maintain coronary perfusion pressure greater than 20 mm Hg; 2) Depth 33 mm: target chest compression depth of 33 mm with standard American Heart Association epinephrine dosing; or 3) Depth 51 mm: target chest compression depth of 51 mm with standard American Heart Association epinephrine dosing. All animals received manual cardiopulmonary resuscitation guided by audiovisual feedback for 10 minutes before first shock. Forty-five-minute survival was higher in the coronary perfusion pressure-20 group (8 of 8) compared to depth 33 mm (1 of 8) or depth 51 mm (3 of 8) groups; p equals to 0.002. Coronary perfusion pressures were higher in the coronary perfusion pressure-20 group compared to depth 33 mm (p = 0.004) and depth 51 mm (p = 0.006) and in survivors compared to nonsurvivors (p < 0.01). Total epinephrine dosing and defibrillation attempts were not different. Hemodynamic directed resuscitation targeting coronary perfusion pressures greater than 20 mm Hg during 10 minutes of cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest improves short-term survival, when compared to resuscitation with depth of compressions guided to 33 mm or 51 mm and standard American Heart Association vasopressor dosing.

  13. The effect on quality of chest compressions and exhaustion of a compression--ventilation ratio of 30:2 versus 15:2 during cardiopulmonary resuscitation--a randomised trial.

    PubMed

    Deschilder, Koen; De Vos, Rien; Stockman, Willem

    2007-07-01

    Recent cardio pulmonary resuscitation (CPR) guidelines changed the compression:ventilation ratio in 30:2. To compare the quality of chest compressions and exhaustion using the ratio 30:2 versus 15:2. A prospective, randomised crossover design was used. Subjects were recruited from the H.-Hart hospital personnel and the University College Katho for nurses and bio-engineering. Each participant performed 5min of CPR using either the ratio 30:2 or 15:2, then after a 15min rest switched to the other ratio. The data were collected using a questionnaire and an adult resuscitation manikin. The outcomes included exhaustion as measured by a visual analogue scale (VAS) score, depth of chest compressions, rates of chest compressions, total number of chest compressions, number of correct chest compressions and incomplete release. Data were compared using the Wilcoxon Signed Ranks Test. The results are presented as medians and interquartile ranges (IQR). One hundred and thirty subjects completed the study. The exhaustion-score using the VAS was 5.9 (IQR 2.25) for the ratio 30:2 and 4.5 (IQR 2.88) for the ratio 15:2 (P<0.001). The compression depth was 40.5mm (IQR 15.75) for 30:2 and 41mm (IQR 15.5) for 15:2 (P=0.5). The compression rate was 118beats/min (IQR 29) for 30:2 and 115beats/min (IQR 32) for 15:2 (P=0.02). The total number of compressions/5min was 347 (IQR 79) for 30:2 and 244compressions/5min (IQR 72.5) for 15:2 (P<0.001). The number of correct compression/5min was 61.5 (IQR 211.75) for 30:2 and 55.5 (IQR 142.75) for 15:2 (P=0.001). The relative risk (RR) of incomplete release in 30:2 versus 15:2 was 1.087 (95% CI=0.633-1.867). Although the 30:2 ratio is rated to be more exhausting, the 30:2 technique delivers more chest compressions and the quality of chest compressions remains unchanged.

  14. The capability of professional- and lay-rescuers to estimate the chest compression-depth target: a short, randomized experiment.

    PubMed

    van Tulder, Raphael; Laggner, Roberta; Kienbacher, Calvin; Schmid, Bernhard; Zajicek, Andreas; Haidvogel, Jochen; Sebald, Dieter; Laggner, Anton N; Herkner, Harald; Sterz, Fritz; Eisenburger, Philip

    2015-04-01

    In CPR, sufficient compression depth is essential. The American Heart Association ("at least 5cm", AHA-R) and the European Resuscitation Council ("at least 5cm, but not to exceed 6cm", ERC-R) recommendations differ, and both are hardly achieved. This study aims to investigate the effects of differing target depth instructions on compression depth performances of professional and lay-rescuers. 110 professional-rescuers and 110 lay-rescuers were randomized (1:1, 4 groups) to estimate the AHA-R or ERC-R on a paper sheet (given horizontal axis) using a pencil and to perform chest compressions according to AHA-R or ERC-R on a manikin. Distance estimation and compression depth were the outcome variables. Professional-rescuers estimated the distance according to AHA-R in 19/55 (34.5%) and to ERC-R in 20/55 (36.4%) cases (p=0.84). Professional-rescuers achieved correct compression depth according to AHA-R in 39/55 (70.9%) and to ERC-R in 36/55 (65.4%) cases (p=0.97). Lay-rescuers estimated the distance correctly according to AHA-R in 18/55 (32.7%) and to ERC-R in 20/55 (36.4%) cases (p=0.59). Lay-rescuers yielded correct compression depth according to AHA-R in 39/55 (70.9%) and to ERC-R in 26/55 (47.3%) cases (p=0.02). Professional and lay-rescuers have severe difficulties in correctly estimating distance on a sheet of paper. Professional-rescuers are able to yield AHA-R and ERC-R targets likewise. In lay-rescuers AHA-R was associated with significantly higher success rates. The inability to estimate distance could explain the failure to appropriately perform chest compressions. For teaching lay-rescuers, the AHA-R with no upper limit of compression depth might be preferable. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Instructions to "put the phone down" do not improve the quality of bystander initiated dispatcher-assisted cardiopulmonary resuscitation.

    PubMed

    Brown, Todd B; Saini, Devashish; Pepper, Tracy; Mirza, Muzna; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S

    2008-02-01

    The quality of early bystander CPR appears important in maximizing survival. This trial tests whether explicit instructions to "put the phone down" improve the quality of bystander initiated dispatch-assisted CPR. In a randomized, double-blinded, controlled trial, subjects were randomized to a modified version of the Medical Priority Dispatch System (MPDS) version 11.2 protocol or a simplified protocol, each with or without instruction to "put the phone down" during CPR. Data were recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions. Primary outcome measures included chest compression rate, depth, and the proportion of compressions without error, with correct hand position, adequate depth, and total release. Time was measured in two distinct ways: time required for initiation of CPR and total amount of time hands were off the chest during CPR. Proportions were analyzed by Wilcoxon rank sum tests and time variables with ANOVA. All tests used a two-sided alpha-level of 0.05. Two hundred and fifteen subjects were randomized-107 in the "put the phone down" instruction group and 108 in the group without "put the phone down" instructions. The groups were comparable across demographic and experiential variables. The additional instruction to "put the phone down" had no effect on the proportion of compressions administered without error, with the correct depth, and with the correct hand position. Likewise, "put the phone down" did not affect the average compression depth, the average compression rate, the total hands-off-chest time, or the time to initiate chest compressions. A statistically significant, yet trivial, effect was found in the proportion of compressions with total release of the chest wall. Instructions to "put the phone down" had no effect on the quality of bystander initiated dispatcher-assisted CPR in this trial.

  16. Corpuls cpr resuscitation device generates superior emulated flows and pressures than LUCAS II in a mechanical thorax model.

    PubMed

    Eichhorn, S; Mendoza Garcia, A; Polski, M; Spindler, J; Stroh, A; Heller, M; Lange, R; Krane, M

    2017-06-01

    The provision of sufficient chest compression is among the most important factors influencing patient survival during cardiopulmonary resuscitation (CPR). One approach to optimize the quality of chest compressions is to use mechanical-resuscitation devices. The aim of this study was to compare a new device for chest compression (corpuls cpr) with an established device (LUCAS II). We used a mechanical thorax model consisting of a chest with variable stiffness and an integrated heart chamber which generated blood flow dependent on the compression depth and waveform. The method of blood-flow generation could be changed between direct cardiac-compression mode and thoracic-pump mode. Different chest-stiffness settings and compression modes were tested to generate various blood-flow profiles. Additionally, an endurance test at high stiffness was performed to measure overall performance and compression consistency. Both resuscitation machines were able to compress the model thorax with a frequency of 100/min and a depth of 5 cm, independent of the chosen chest stiffness. Both devices passed the endurance test without difficulty. The corpuls cpr device was able to generate about 10-40% more blood flow than the LUCAS II device, depending on the model settings. In most scenarios, the corpuls cpr device also generated a higher blood pressure than the LUCAS II. The peak compression forces during CPR were about 30% higher using the corpuls cpr device than with the LUCAS II. In this study, the corpuls cpr device had improved blood flow and pressure outcomes than the LUCAS II device. Further examination in an animal model is required to prove the findings of this preliminary study.

  17. Accurate measurement of chest compression depth using impulse-radio ultra-wideband sensor on a mattress

    PubMed Central

    Kim, Yeomyung

    2017-01-01

    Objective We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Methods Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. Results The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). Conclusion The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress. PMID:28854262

  18. Accurate measurement of chest compression depth using impulse-radio ultra-wideband sensor on a mattress.

    PubMed

    Yu, Byung Gyu; Oh, Je Hyeok; Kim, Yeomyung; Kim, Tae Wook

    2017-01-01

    We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress.

  19. Efficacy of metronome sound guidance via a phone speaker during dispatcher-assisted compression-only cardiopulmonary resuscitation by an untrained layperson: a randomised controlled simulation study using a manikin.

    PubMed

    Park, Sang O; Hong, Chong Kun; Shin, Dong Hyuk; Lee, Jun Ho; Hwang, Seong Youn

    2013-08-01

    Untrained laypersons should perform compression-only cardiopulmonary resuscitation (COCPR) under a dispatcher's guidance, but the quality of the chest compressions may be suboptimal. We hypothesised that providing metronome sounds via a phone speaker may improve the quality of chest compressions during dispatcher-assisted COCPR (DA-COCPR). Untrained laypersons were allocated to either the metronome sound-guided group (MG), who performed DA-COCPR with metronome sounds (110 ticks/min), or the control group (CG), who performed conventional DA-COCPR. The participants of each group performed DA-COCPR for 4 min using a manikin with Skill-Reporter, and the data regarding chest compression quality were collected. The data from 33 cases of DA-COCPR in the MG and 34 cases in the CG were compared. The MG showed a faster compression rate than the CG (111.9 vs 96.7/min; p=0.018). A significantly higher proportion of subjects in the MG performed the DA-COCPR with an accurate chest compression rate (100-120/min) compared with the subjects in the CG (32/33 (97.0%) vs 5/34 (14.7%); p<0.0001). The mean compression depth was not different between the MG and the CG (45.9 vs 46.8 mm; p=0.692). However, a higher proportion of subjects in the MG performed shallow compressions (compression depth <38 mm) compared with subjects in the CG (median % was 69.2 vs 15.7; p=0.035). Metronome sound guidance during DA-COCPR for the untrained bystanders improved the chest compression rates, but was associated more with shallow compressions than the conventional DA-COCPR in a manikin model.

  20. Analysis of actual pressure point using the power flexible capacitive sensor during chest compression.

    PubMed

    Minami, Kouichiro; Kokubo, Yota; Maeda, Ichinosuke; Hibino, Shingo

    2017-02-01

    In chest compression for cardiopulmonary resuscitation (CPR), the lower half of the sternum is pressed according to the American Heart Association (AHA) guidelines 2010. These have been no studies which identify the exact location of the applied by individual chest compressions. We developed a rubber power-flexible capacitive sensor that could measure the actual pressure point of chest compression in real time. Here, we examined the pressure point of chest compression by ambulance crews during CPR using a mannequin. We included 179 ambulance crews. Chest compression was performed for 2 min. The pressure position was monitored, and the quality of chest compression was analyzed by using a flexible pressure sensor (Shinnosukekun™). Of the ambulance crews, 58 (32.4 %) pressed the center and 121 (67.6 %) pressed outside the proper area of chest compression. Many of them pressed outside the center; 8, 7, 41, and 90 pressed on the caudal, left, right, and cranial side, respectively. Average compression rate, average recoil, average depth, and average duty cycle were 108.6 counts per minute, 0.089, 4.5 cm, and 48.27 %, respectively. Many of the ambulance crews did not press on the sternal lower half definitely. This new device has the potential to improve the quality of CPR during training or in clinical practice.

  1. Effect of 3basic life support training programs in future primary school teachers. A quasi-experimental design.

    PubMed

    Navarro-Patón, R; Freire-Tellado, M; Basanta-Camiño, S; Barcala-Furelos, R; Arufe-Giraldez, V; Rodriguez-Fernández, J E

    2018-05-01

    To evaluate the learning of basic life support (BLS) measures on the part of laypersons after 3different teaching programs. A quasi-experimental before-after study involving a non-probabilistic sample without a control group was carried out. Primary school teacher students from the University of Santiago (Spain). A total of 124 students (68.8% women and 31.2% men) aged 20-39 years (M=22.23; SD=3.79), with no previous knowledge of BLS, were studied. Three teaching programs were used: a traditional course, an audio-visual approach and feedback devices. Chest compressions as sole cardiopulmonary resuscitation skill evaluation: average compression depth, compression rate, chest recoil percentage and percentage of correct compressions. Automated external defibrillator: time needed to apply a shock before and after the course. There were significant differences in the results obtained after 2minutes of chest compressions, depending on the training program received, with feedback devices having a clear advantage referred to average compression depth (p<0.001), compression rate (p<0.001), chest recoil percentage (p<0.001) and percentage of correct compressions (p<0.001). Regarding automated external defibrillator, statistically significant differences were found in T after (p=0.025). The teaching course using feedback devices obtained the best results in terms of the quality of chest compressions, followed by the traditional course and audio-visual approach. These favorable results were present in both men and women. All 3teaching methods reached the goal of reducing defibrillation time. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  2. Two-thumb technique is superior to two-finger technique during lone rescuer infant manikin CPR.

    PubMed

    Udassi, Sharda; Udassi, Jai P; Lamb, Melissa A; Theriaque, Douglas W; Shuster, Jonathan J; Zaritsky, Arno L; Haque, Ikram U

    2010-06-01

    Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as p< or =0.05. Mean % effective breaths were 90+/-18.6% in two-thumb and 88.9+/-21.1% in two-finger, p=0.65. Mean time (s) to deliver two mouth-to-mouth breaths was 7.6+/-1.6 in two-thumb and 7.0+/-1.5 in two-finger, p<0.0001. Mean delivered compressions per minute were 87+/-11 in two-thumb and 92+/-12 in two-finger, p=0.0005. Two-thumb resulted in significantly higher compression depth and compression pressure compared to the two-finger technique. Healthcare providers required 0.6s longer time to deliver two breaths during two-thumb lone rescuer infant CPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Performance of cardiopulmonary resuscitation during prolonged basic life support in military medical university students: A manikin study.

    PubMed

    Wang, Juan; Zhuo, Chao-Nan; Zhang, Lei; Gong, Yu-Shun; Yin, Chang-Lin; Li, Yong-Qin

    2015-01-01

    The quality of chest compressions can be significantly improved after training of rescuers according to the latest national guidelines of China. However, rescuers may be unable to maintain adequate compression or ventilation throughout a response of average emergency medical services because of increased rescuer fatigue. In the present study, we evaluated the performance of cardiopulmonary resuscitation (CPR) in training of military medical university students during a prolonged basic life support (BLS). A 3-hour BLS training was given to 120 military medical university students. Six months after the training, 115 students performed single rescuer BLS on a manikin for 8 minutes. The qualities of chest compressions as well as ventilations were assessed. The average compression depth and rate were 53.7±5.3 mm and 135.1±15.7 compressions per minute respectively. The proportion of chest compressions with appropriate depth was 71.7%±28.4%. The average ventilation volume was 847.2±260.4 mL and the proportion of students with adequate ventilation was 63.5%. Compared with male students, significantly lower compression depth (46.7±4.8 vs. 54.6±4.8 mm, P<0.001) and adequate compression rate (35.5%±26.5% vs. 76.1%±25.1%, P<0.001) were observed in female students. CPR was found to be related to gender, body weight, and body mass index of students in this study. The quality of chest compressions was well maintained in male students during 8 minutes of conventional CPR but declined rapidly in female students after 2 minutes according to the latest national guidelines. Physical fitness and rescuer fatigue did not affect the quality of ventilation.

  4. Performance of cardiopulmonary resuscitation during prolonged basic life support in military medical university students: A manikin study

    PubMed Central

    Wang, Juan; Zhuo, Chao-nan; Zhang, Lei; Gong, Yu-shun; Yin, Chang-lin; Li, Yong-qin

    2015-01-01

    BACKGROUND: The quality of chest compressions can be significantly improved after training of rescuers according to the latest national guidelines of China. However, rescuers may be unable to maintain adequate compression or ventilation throughout a response of average emergency medical services because of increased rescuer fatigue. In the present study, we evaluated the performance of cardiopulmonary resuscitation (CPR) in training of military medical university students during a prolonged basic life support (BLS). METHODS: A 3-hour BLS training was given to 120 military medical university students. Six months after the training, 115 students performed single rescuer BLS on a manikin for 8 minutes. The qualities of chest compressions as well as ventilations were assessed. RESULTS: The average compression depth and rate were 53.7±5.3 mm and 135.1±15.7 compressions per minute respectively. The proportion of chest compressions with appropriate depth was 71.7%±28.4%. The average ventilation volume was 847.2±260.4 mL and the proportion of students with adequate ventilation was 63.5%. Compared with male students, significantly lower compression depth (46.7±4.8 vs. 54.6±4.8 mm, P<0.001) and adequate compression rate (35.5%±26.5% vs. 76.1%±25.1%, P<0.001) were observed in female students. CONCLUSIONS: CPR was found to be related to gender, body weight, and body mass index of students in this study. The quality of chest compressions was well maintained in male students during 8 minutes of conventional CPR but declined rapidly in female students after 2 minutes according to the latest national guidelines. Physical fitness and rescuer fatigue did not affect the quality of ventilation. PMID:26401177

  5. A Randomized Control Trial of Cardiopulmonary Feedback Devices and Their Impact on Infant Chest Compression Quality: A Simulation Study.

    PubMed

    Austin, Andrea L; Spalding, Carmen N; Landa, Katrina N; Myer, Brian R; Donald, Cure; Smith, Jason E; Platt, Gerald; King, Heather C

    2017-10-27

    In effort to improve chest compression quality among health care providers, numerous feedback devices have been developed. Few studies, however, have focused on the use of cardiopulmonary resuscitation feedback devices for infants and children. This study evaluated the quality of chest compressions with standard team-leader coaching, a metronome (MetroTimer by ONYX Apps), and visual feedback (SkillGuide Cardiopulmonary Feedback Device) during simulated infant cardiopulmonary resuscitation. Seventy voluntary health care providers who had recently completed Pediatric Advanced Life Support or Basic Life Support courses were randomized to perform simulated infant cardiopulmonary resuscitation into 1 of 3 groups: team-leader coaching alone (control), coaching plus metronome, or coaching plus SkillGuide for 2 minutes continuously. Rate, depth, and frequency of complete recoil during cardiopulmonary resuscitation were recorded by the Laerdal SimPad device for each participant. American Heart Association-approved compression techniques were randomized to either 2-finger or encircling thumbs. The metronome was associated with more ideal compression rate than visual feedback or coaching alone (104/min vs 112/min and 113/min; P = 0.003, 0.019). Visual feedback was associated with more ideal depth than auditory (41 mm vs 38.9; P = 0.03). There were no significant differences in complete recoil between groups. Secondary outcomes of compression technique revealed a difference of 1 mm. Subgroup analysis of male versus female showed no difference in mean number of compressions (221.76 vs 219.79; P = 0.72), mean compression depth (40.47 vs 39.25; P = 0.09), or rate of complete release (70.27% vs 64.96%; P = 0.54). In the adult literature, feedback devices often show an increase in quality of chest compressions. Although more studies are needed, this study did not demonstrate a clinically significant improvement in chest compressions with the addition of a metronome or visual feedback device, no clinically significant difference in Pediatric Advanced Life Support-approved compression technique, and no difference between compression quality between genders.

  6. [At what age can children perform effective cardiopulmonary resuscitation? - Effectiveness of cardiopulmonary resuscitation skills among primary school children].

    PubMed

    Bánfai, Bálint; Pandur, Attila; Pék, Emese; Csonka, Henrietta; Betlehem, József

    2017-01-01

    In cardiac arrest life can be saved by bystanders. Our aim was to determine at what age can schoolchildren perform correct cardiopulmonary resuscitation. 164 schoolchildren (age 7-14) were involved in the study. A basic life support training consisted of 45 minutes education in small groups (8-10 children). They were tested during a 2-minute-long continuous cardiopulmonary resuscitation scenario using the "AMBU CPR Software". Average depth of chest compression was 44.07 ± 12.6 mm. 43.9% of participants were able to do effective chest compressions. Average ventilation volume was 0.17 ± 0.31 liter. 12.8% of participants were able to ventilate effectively the patient. It was significant correlation between the chest compression depth (p<0.001) and ventilation (p<0.001) and the children's age, weight, height and BMI. Primary school children are able to learn cardiopulmonary resuscitation. The ability to do effective chest compressions and ventilation depended on the children's physical capability. Orv. Hetil., 2017, 158(4), 147-152.

  7. Use of a Metronome in Cardiopulmonary Resuscitation: A Simulation Study.

    PubMed

    Zimmerman, Elise; Cohen, Naiomi; Maniaci, Vincenzo; Pena, Barbara; Lozano, Juan Manuel; Linares, Marc

    2015-11-01

    Determine whether the use of a metronome improves chest compression rate and depth during cardiopulmonary resuscitation (CPR) on a pediatric manikin. A prospective, simulation-based, crossover, randomized controlled trial was conducted. Participants included pediatric residents, fellows, nurses, and medical students who were randomly assigned to perform chest compressions on a pediatric manikin with and without an audible metronome. Each participant performed 2 rounds of 2 minutes of chest compressions separated by a 15-minute break. A total of 155 participants performed 2 rounds of chest compressions (74 with the metronome on during the first round and 81 with the metronome on during the second round of CPR). There was a significant improvement in the mean percentage of compressions delivered within an adequate rate (90-100 compressions per minute) with the metronome on compared with off (72% vs 50%; mean difference [MD] 22%; 95% confidence interval [CI], 15% to 29%). No significant difference was noted in the mean percentage of compressions within acceptable depth (38-51 mm) (72% vs 70%; MD 2%; 95% CI, -2% to 6%). The metronome had a larger effect among medical students (73% vs 55%; MD 18%; 95% CI, 8% to 28%) and pediatric residents and fellows (84% vs 48%; MD 37%; 95% CI, 27% to 46%) but not among pediatric nurses (46% vs 48%; MD -3%; 95% CI, -19% to 14%). The rate of chest compressions during CPR can be optimized by the use of a metronome. These findings will help medical professionals comply with the American Heart Association guidelines. Copyright © 2015 by the American Academy of Pediatrics.

  8. Efficacy of chest compressions directed by end-tidal CO2 feedback in a pediatric resuscitation model of basic life support.

    PubMed

    Hamrick, Jennifer L; Hamrick, Justin T; Lee, Jennifer K; Lee, Benjamin H; Koehler, Raymond C; Shaffner, Donald H

    2014-04-14

    End-tidal carbon dioxide (ETCO2) correlates with systemic blood flow and resuscitation rate during cardiopulmonary resuscitation (CPR) and may potentially direct chest compression performance. We compared ETCO2-directed chest compressions with chest compressions optimized to pediatric basic life support guidelines in an infant swine model to determine the effect on rate of return of spontaneous circulation (ROSC). Forty 2-kg piglets underwent general anesthesia, tracheostomy, placement of vascular catheters, ventricular fibrillation, and 90 seconds of no-flow before receiving 10 or 12 minutes of pediatric basic life support. In the optimized group, chest compressions were optimized by marker, video, and verbal feedback to obtain American Heart Association-recommended depth and rate. In the ETCO2-directed group, compression depth, rate, and hand position were modified to obtain a maximal ETCO2 without video or verbal feedback. After the interval of pediatric basic life support, external defibrillation and intravenous epinephrine were administered for another 10 minutes of CPR or until ROSC. Mean ETCO2 at 10 minutes of CPR was 22.7±7.8 mm Hg in the optimized group (n=20) and 28.5±7.0 mm Hg in the ETCO2-directed group (n=20; P=0.02). Despite higher ETCO2 and mean arterial pressure in the latter group, ROSC rates were similar: 13 of 20 (65%; optimized) and 14 of 20 (70%; ETCO2 directed). The best predictor of ROSC was systemic perfusion pressure. Defibrillation attempts, epinephrine doses required, and CPR-related injuries were similar between groups. The use of ETCO2-directed chest compressions is a novel guided approach to resuscitation that can be as effective as standard CPR optimized with marker, video, and verbal feedback.

  9. 50% duty cycle may be inappropriate to achieve a sufficient chest compression depth when cardiopulmonary resuscitation is performed by female or light rescuers.

    PubMed

    Lee, Chang Jae; Chung, Tae Nyoung; Bae, Jinkun; Kim, Eui Chung; Choi, Sung Wook; Kim, Ok Jun

    2015-03-01

    Current guidelines for cardiopulmonary resuscitation recommend chest compressions (CC) during 50% of the duty cycle (DC) in part because of the ease with which individuals may learn to achieve it with practice. However, no consideration has been given to a possible interaction between DC and depth of CC, which has been the subject of recent study. Our aim was to determine if 50% DC is inappropriate to achieve sufficient chest compression depth for female and light rescuers. Previously collected CC data, performed by senior medical students guided by metronome sounds with various down-stroke patterns and rates, were included in the analysis. Multiple linear regression analysis was performed to determine the association between average compression depth (ACD) with average compression rate (ACR), DC, and physical characteristics of the performers. Expected ACD was calculated for various settings. DC, ACR, body weight, male sex, and self-assessed physical strength were significantly associated with ACD in multivariate analysis. Based on our calculations, with 50% of DC, only men with ACR of 140/min or faster or body weight over 74 kg with ACR of 120/min can achieve sufficient ACD. A shorter DC is independently correlated with deeper CC during simulated cardiopulmonary resuscitation. The optimal DC recommended in current guidelines may be inappropriate for achieving sufficient CD, especially for female or lighter-weight rescuers.

  10. The prevalence of chest compression leaning during in-hospital cardiopulmonary resuscitation

    PubMed Central

    Fried, David A.; Leary, Marion; Smith, Douglas A.; Sutton, Robert M.; Niles, Dana; Herzberg, Daniel L.; Becker, Lance B.; Abella, Benjamin S.

    2011-01-01

    Objective Successful resuscitation from cardiac arrest requires the delivery of high-quality chest compressions, encompassing parameters such as adequate rate, depth, and full recoil between compressions. The lack of compression recoil (“leaning” or “incomplete recoil”) has been shown to adversely affect hemodynamics in experimental arrest models, but the prevalence of leaning during actual resuscitation is poorly understood. We hypothesized that leaning varies across resuscitation events, possibly due to rescuer and/or patient characteristics and may worsen over time from rescuer fatigue during continuous chest compressions. Methods This was an observational clinical cohort study at one academic medical center. Data were collected from adult in-hospital and Emergency Department arrest events using monitor/defibrillators that record chest compression characteristics and provide real-time feedback. Results We analyzed 112,569 chest compressions from 108 arrest episodes from 5/2007 to 2/2009. Leaning was present in 98/108 (91%) cases; 12% of all compressions exhibited leaning. Leaning varied widely across cases: 41/108 (38%) of arrest episodes exhibited <5% leaning yet 20/108 (19%) demonstrated >20% compression leaning. When evaluating blocks of continuous compressions (>120 sec), only 4/33 (12%) had an increase in leaning over time and 29/33 (88%) showed a decrease (p<0.001). Conclusions Chest compression leaning was common during resuscitation care and exhibited a wide distribution, with most leaning within a subset of resuscitations. Leaning decreased over time during continuous chest compression blocks, suggesting that either leaning may not be a function of rescuer fatiguing, or that it may have been mitigated by automated feedback provided during resuscitation episodes. PMID:21482010

  11. Role of dominant versus non-dominant hand position during uninterrupted chest compression CPR by novice rescuers: a randomized double-blind crossover study.

    PubMed

    Nikandish, Reza; Shahbazi, Sharbanoo; Golabi, Sedigheh; Beygi, Najimeh

    2008-02-01

    Previous research has suggested improved quality of chest compressions when the dominant hand was in contact with the sternum. However, the study was in health care professionals and during conventional chest compression-ventilation CPR. The aim of this study was to test the hypothesis, in null form, that the quality of external chest compressions (ECC) in novice rescuers during 5min of uninterrupted chest compression CPR (UCC-CPR) is independent of the hand in contact with the sternum. Confirmation of the hypothesis would allow the use of either hand by the novice rescuers during UCC-CPR. Fifty-nine first year public heath students participated in this randomised double-blind crossover study. After completion of a standard adult BLS course, they performed single rescuer adult UCC-CPR for 5 min on a recording Resusci Anne. One week later they changed the hand of contact with the sternum while performing ECC. The quality of ECC was recorded by the skill meter for the dominant and non-dominant hand during 5 min ECC. The total number of correct chest compressions in the dominant hand group (DH), mean 183+/-152, was not statistically different from the non-dominant hand group (NH), mean 152+/-135 (P=0.09). The number of ECC with inadequate depth in the DH group, mean 197+/-174 and NH group, mean 196+/-173 were comparable (P=0.1). The incidence of ECC exceeding the recommended depth in the DH group, mean 51+/-110 and NH group, mean 32+/-75 were comparable (P=0.1). Although there is a trend to increased incidence of correct chest compressions with positioning the dominant hand in contact with the sternum, it does not reach statistical significance during UCC-CPR by the novice rescuers for 5 min.

  12. [Effects of real-time audiovisual feedback on secondary-school students' performance of chest compressions].

    PubMed

    Abelairas-Gómez, Cristian; Rodríguez-Núñez, Antonio; Vilas-Pintos, Elisardo; Prieto Saborit, José Antonio; Barcala-Furelos, Roberto

    2015-06-01

    To describe the quality of chest compressions performed by secondary-school students trained with a realtime audiovisual feedback system. The learners were 167 students aged 12 to 15 years who had no prior experience with cardiopulmonary resuscitation (CPR). They received an hour of instruction in CPR theory and practice and then took a 2-minute test, performing hands-only CPR on a child mannequin (Prestan Professional Child Manikin). Lights built into the mannequin gave learners feedback about how many compressions they had achieved and clicking sounds told them when compressions were deep enough. All the learners were able to maintain a steady enough rhythm of compressions and reached at least 80% of the targeted compression depth. Fewer correct compressions were done in the second minute than in the first (P=.016). Real-time audiovisual feedback helps schoolchildren aged 12 to 15 years to achieve quality chest compressions on a mannequin.

  13. Optimal chest compression rate in cardiopulmonary resuscitation: a prospective, randomized crossover study using a manikin model.

    PubMed

    Lee, Seong Hwa; Ryu, Ji Ho; Min, Mun Ki; Kim, Yong In; Park, Maeng Real; Yeom, Seok Ran; Han, Sang Kyoon; Park, Seong Wook

    2016-08-01

    When performing cardiopulmonary resuscitation (CPR), the 2010 American Heart Association guidelines recommend a chest compression rate of at least 100 min, whereas the 2010 European Resuscitation Council guidelines recommend a rate of between 100 and 120 min. The aim of this study was to examine the rate of chest compression that fulfilled various quality indicators, thereby determining the optimal rate of compression. Thirty-two trainee emergency medical technicians and six paramedics were enrolled in this study. All participants had been trained in basic life support. Each participant performed 2 min of continuous compressions on a skill reporter manikin, while listening to a metronome sound at rates of 100, 120, 140, and 160 beats/min, in a random order. Mean compression depth, incomplete chest recoil, and the proportion of correctly performed chest compressions during the 2 min were measured and recorded. The rate of incomplete chest recoil was lower at compression rates of 100 and 120 min compared with that at 160 min (P=0.001). The numbers of compressions that fulfilled the criteria for high-quality CPR at a rate of 120 min were significantly higher than those at 100 min (P=0.016). The number of high-quality CPR compressions was the highest at a compression rate of 120 min, and increased incomplete recoil occurred with increasing compression rate. However, further studies are needed to confirm the results.

  14. Influence of chest compression artefact on capnogram-based ventilation detection during out-of-hospital cardiopulmonary resuscitation.

    PubMed

    Leturiondo, Mikel; Ruiz de Gauna, Sofía; Ruiz, Jesus M; Julio Gutiérrez, J; Leturiondo, Luis A; González-Otero, Digna M; Russell, James K; Zive, Dana; Daya, Mohamud

    2018-03-01

    Capnography has been proposed as a method for monitoring the ventilation rate during cardiopulmonary resuscitation (CPR). A high incidence (above 70%) of capnograms distorted by chest compression induced oscillations has been previously reported in out-of-hospital (OOH) CPR. The aim of the study was to better characterize the chest compression artefact and to evaluate its influence on the performance of a capnogram-based ventilation detector during OOH CPR. Data from the MRx monitor-defibrillator were extracted from OOH cardiac arrest episodes. For each episode, presence of chest compression artefact was annotated in the capnogram. Concurrent compression depth and transthoracic impedance signals were used to identify chest compressions and to annotate ventilations, respectively. We designed a capnogram-based ventilation detection algorithm and tested its performance with clean and distorted episodes. Data were collected from 232 episodes comprising 52 654 ventilations, with a mean (±SD) of 227 (±118) per episode. Overall, 42% of the capnograms were distorted. Presence of chest compression artefact degraded algorithm performance in terms of ventilation detection, estimation of ventilation rate, and the ability to detect hyperventilation. Capnogram-based ventilation detection during CPR using our algorithm was compromised by the presence of chest compression artefact. In particular, artefact spanning from the plateau to the baseline strongly degraded ventilation detection, and caused a high number of false hyperventilation alarms. Further research is needed to reduce the impact of chest compression artefact on capnographic ventilation monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Perception of CPR quality: Influence of CPR feedback, Just-in-Time CPR training and provider role.

    PubMed

    Cheng, Adam; Overly, Frank; Kessler, David; Nadkarni, Vinay M; Lin, Yiqun; Doan, Quynh; Duff, Jonathan P; Tofil, Nancy M; Bhanji, Farhan; Adler, Mark; Charnovich, Alex; Hunt, Elizabeth A; Brown, Linda L

    2015-02-01

    Many healthcare providers rely on visual perception to guide cardiopulmonary resuscitation (CPR), but little is known about the accuracy of provider perceptions of CPR quality. We aimed to describe the difference between perceived versus measured CPR quality, and to determine the impact of provider role, real-time visual CPR feedback and Just-in-Time (JIT) CPR training on provider perceptions. We conducted secondary analyses of data collected from a prospective, multicenter, randomized trial of 324 healthcare providers who participated in a simulated cardiac arrest scenario between July 2012 and April 2014. Participants were randomized to one of four permutations of: JIT CPR training and real-time visual CPR feedback. We calculated the difference between perceived and measured quality of CPR and reported the proportion of subjects accurately estimating the quality of CPR within each study arm. Participants overestimated achieving adequate chest compression depth (mean difference range: 16.1-60.6%) and rate (range: 0.2-51%), and underestimated chest compression fraction (0.2-2.9%) across all arms. Compared to no intervention, the use of real-time feedback and JIT CPR training (alone or in combination) improved perception of depth (p<0.001). Accurate estimation of CPR quality was poor for chest compression depth (0-13%), rate (5-46%) and chest compression fraction (60-63%). Perception of depth is more accurate in CPR providers versus team leaders (27.8% vs. 7.4%; p=0.043) when using real-time feedback. Healthcare providers' visual perception of CPR quality is poor. Perceptions of CPR depth are improved by using real-time visual feedback and with prior JIT CPR training. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Improved chest recoil using an adhesive glove device for active compression–decompression CPR in a pediatric manikin model☆

    PubMed Central

    Udassi, Jai P.; Udassi, Sharda; Lamb, Melissa A.; Lamb, Kenneth E.; Theriaque, Douglas W.; Shuster, Jonathan J.; Zaritsky, Arno L.; Haque, Ikram U.

    2013-01-01

    Objective We developed an adhesive glove device (AGD) to perform ACD-CPR in pediatric manikins, hypothesizing that AGD-ACD-CPR provides better chest decompression compared to standard (S)-CPR. Design Split-plot design randomizing 16 subjects to test four manikin-technique models in a crossover fashion to AGD-ACD-CPR vs. S-CPR. Healthcare providers performed 5 min of CPR with 30:2 compression:ventilation ratio in the four manikin models: (1) adolescent; (2) child two-hand; (3) child one-hand; and (4) infant two-thumb. Methods Modified manikins recorded compression pressure (CP), compression depth (CD) and decompression depth (DD). The AGD consisted of a modified oven mitt with an adjustable strap; a Velcro patch was sewn to the palmer aspect. The counter Velcro patch was bonded to the anterior chest wall. For infant CPR, the thumbs of two oven mitts were stitched together with Velcro. Subjects were asked to actively pull up during decompression. Subjects’ heart rate (HR), respiratory rate (RR) and recovery time (RT) for HR/RR to return to baseline were recorded. Subjects were blinded to data recordings. Data (mean ± SEM) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as P ≤ 0.05. Results Mean decompression depth difference was significantly greater with AGD-ACD-CPR compared to S-CPR; 38–75% of subjects achieved chest decompression to or beyond baseline. AGD-ACD-CPR provided 6–12% fewer chest compressions/minute than S-CPR group. There was no significant difference in CD, CP, HR, RR and RT within each group comparing both techniques. Conclusion A simple, inexpensive glove device for ACD-CPR improved chest decompression with emphasis on active pull in manikins without excessive rescuer fatigue. The clinical implication of fewer compressions/minute in the AGD group needs to be evaluated. PMID:19683849

  17. A flexible pressure sensor could correctly measure the depth of chest compression on a mattress.

    PubMed

    Minami, Kouichiro; Kokubo, Yota; Maeda, Ichinosuke; Hibino, Shingo

    2016-05-01

    Feedback devices are used to improve the quality of chest compression (CC). However, reports have noted that accelerometers substantially overestimate depth when cardiopulmonary resuscitation (CPR) is performed on a soft surface. Here, we determined whether a flexible pressure sensor could correctly evaluate the depth CC performed on a mannequin placed on a mattress. Chest compression was performed 100 times/min by a compression machine on the floor or a mattress, and the depth of CC was monitored using a flexible pressure sensor (Shinnosukekun) and CPRmeter(™). The depth of machine-performed CC was consistently 5cm. We compared data from the feedback sensor with the true depth of CC using dual real-time auto feedback system that incorporated an infrared camera (CPR evolution(™)). On the floor, the true depth of CC was 5.0±0.0cm (n=100), or identical to the depth of CC performed by the machine. The Shinnosukekun(™) measured a mean (±SD) CC depth of 5.0±0.1cm (n=100), and the CPRmeter(™) measured a depth of 5.0±0.2cm (n=100). On the mattress, the true depth of CC was 4.4±0.0cm (n=100). The Shinnosukekun(™) measured a mean CC depth of 4.4±0.0cm (n=100), and the CPRmeter(™) measured a depth of 4.7±0.1cm (n=100). The data of CPRmeter(™) were overestimated (P<.0001 between the true depth and the CPRmeter(™)-measured depth). The Shinnosukekun(™) could correctly measure the depth of CC on a mattress. According to our present results, the flexible pressure sensor could be a useful feedback system for CC performed on a soft surface. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. [Real-time feedback systems for improvement of resuscitation quality].

    PubMed

    Lukas, R P; Van Aken, H; Engel, P; Bohn, A

    2011-07-01

    The quality of chest compression is a determinant of survival after cardiac arrest. Therefore, the European Resuscitation Council (ERC) 2010 guidelines on resuscitation strongly focus on compression quality. Despite its impact on survival, observational studies have shown that chest compression quality is not reached by professional rescue teams. Real-time feedback devices for resuscitation are able to measure chest compression during an ongoing resuscitation attempt through a sternal sensor equipped with a motion and pressure detection system. In addition to the electrocardiograph (ECG) ventilation can be detected by transthoracic impedance monitoring. In cases of quality deviation, such as shallow chest compression depth or hyperventilation, feedback systems produce visual or acoustic alarms. Rescuers can thereby be supported and guided to the requested quality in chest compression and ventilation. Feedback technology is currently available both as a so-called stand-alone device and as an integrated feature in a monitor/defibrillator unit. Multiple studies have demonstrated sustainable enhancement in the education of resuscitation due to the use of real-time feedback technology. There is evidence that real-time feedback for resuscitation combined with training and debriefing strategies can improve both resuscitation quality and patient survival. Chest compression quality is an independent predictor for survival in resuscitation and should therefore be measured and documented in further clinical multicenter trials.

  19. Comparison of chest compressions in the standing position beside a bed at knee level and the kneeling position: a non-randomised, single-blind, cross-over trial.

    PubMed

    Oh, Je Hyeok; Kim, Chan Woong; Kim, Sung Eun; Lee, Sang Jin; Lee, Dong Hoon

    2014-07-01

    When rescuers perform cardiopulmonary resuscitation (CPR) from a standing position, the height at which chest compressions are carried out is raised. To determine whether chest compressions delivered on a bed adjusted to rescuer's knee height are as effective as those delivered on the floor. A total of 20 fourth-year medical students participated in the study. The students performed chest compressions for 2 min each on a manikin lying on the floor (test 1) and on a manikin lying on a bed (test 2). The average compression rate (ACR) and the average compression depth (ACD) were compared between the two tests. The ACR was not significantly different between tests 1 and 2 (120.1 to 132.9  vs 115.7 to 131.2 numbers/min, 95% CI, p=0.324). The ACD was also not significantly different between tests 1 and 2 (51.2 to 56.6 vs 49.4 to 55.7 mm, 95% CI, p=0.058). The results suggest that there may be no significant differences in compression rate and depth between CPR performed on manikins placed on the floor and those placed at a rescuer's knee height. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. 50% duty cycle may be inappropriate to achieve a sufficient chest compression depth when cardiopulmonary resuscitation is performed by female or light rescuers

    PubMed Central

    Lee, Chang Jae; Chung, Tae Nyoung; Bae, Jinkun; Kim, Eui Chung; Choi, Sung Wook; Kim, Ok Jun

    2015-01-01

    Objective Current guidelines for cardiopulmonary resuscitation recommend chest compressions (CC) during 50% of the duty cycle (DC) in part because of the ease with which individuals may learn to achieve it with practice. However, no consideration has been given to a possible interaction between DC and depth of CC, which has been the subject of recent study. Our aim was to determine if 50% DC is inappropriate to achieve sufficient chest compression depth for female and light rescuers. Methods Previously collected CC data, performed by senior medical students guided by metronome sounds with various down-stroke patterns and rates, were included in the analysis. Multiple linear regression analysis was performed to determine the association between average compression depth (ACD) with average compression rate (ACR), DC, and physical characteristics of the performers. Expected ACD was calculated for various settings. Results DC, ACR, body weight, male sex, and self-assessed physical strength were significantly associated with ACD in multivariate analysis. Based on our calculations, with 50% of DC, only men with ACR of 140/min or faster or body weight over 74 kg with ACR of 120/min can achieve sufficient ACD. Conclusion A shorter DC is independently correlated with deeper CC during simulated cardiopulmonary resuscitation. The optimal DC recommended in current guidelines may be inappropriate for achieving sufficient CD, especially for female or lighter-weight rescuers. PMID:27752567

  1. Closed-loop controller for chest compressions based on coronary perfusion pressure: a computer simulation study.

    PubMed

    Wang, Chunfei; Zhang, Guang; Wu, Taihu; Zhan, Ningbo; Wang, Yaling

    2016-03-01

    High-quality cardiopulmonary resuscitation contributes to cardiac arrest survival. The traditional chest compression (CC) standard, which neglects individual differences, uses unified standards for compression depth and compression rate in practice. In this study, an effective and personalized CC method for automatic mechanical compression devices is provided. We rebuild Charles F. Babbs' human circulation model with a coronary perfusion pressure (CPP) simulation module and propose a closed-loop controller based on a fuzzy control algorithm for CCs, which adjusts the CC depth according to the CPP. Compared with a traditional proportion-integration-differentiation (PID) controller, the performance of the fuzzy controller is evaluated in computer simulation studies. The simulation results demonstrate that the fuzzy closed-loop controller results in shorter regulation time, fewer oscillations and smaller overshoot than traditional PID controllers and outperforms the traditional PID controller for CPP regulation and maintenance.

  2. Cardiopulmonary resuscitation quality and patient survival outcome in cardiac arrest: A systematic review and meta-analysis.

    PubMed

    Talikowska, Milena; Tohira, Hideo; Finn, Judith

    2015-11-01

    To conduct a systematic review and meta-analysis to determine whether cardiopulmonary resuscitation (CPR) quality, as indicated by parameters such as chest compression depth, compression rate and compression fraction, is associated with patient survival from cardiac arrest. Five databases were searched (MEDLINE, Embase, CINAHL, Scopus and Cochrane) as well as the grey literature (MedNar). To satisfy inclusion criteria, studies had to document human cases of in- or out-of hospital cardiac arrest where CPR quality had been recorded using an automated device and linked to patient survival. Where indicated (I(2)<75%), meta-analysis was undertaken to examine the relationship between individual CPR quality parameters and either survival to hospital discharge (STHD) or return of spontaneous circulation (ROSC). Database searching yielded 8,842 unique citations, resulting in the inclusion of 22 relevant articles. Thirteen were included in the meta-analysis. Chest compression depth was significantly associated with STHD (mean difference (MD) between survivors and non-survivors 2.59 mm, 95% CI: 0.71, 4.47); and with ROSC (MD 0.99 mm, 95% CI: 0.04, 1.93). Within the range of approximately 100-120 compressions per minute (cpm), compression rate was significantly associated with STHD; survivors demonstrated a lower mean compression rate than non-survivors (MD -1.17 cpm, 95% CI: -2.21, -0.14). Compression fraction could not be examined by meta-analysis due to high heterogeneity, however a higher fraction appeared to be associated with survival in cases with a shockable initial rhythm. Chest compression depth and rate were associated with survival outcomes. More studies with consistent reporting of data are required for other quality parameters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Simplified dispatch-assisted CPR instructions outperform standard protocol.

    PubMed

    Dias, J A; Brown, T B; Saini, D; Shah, R C; Cofield, S S; Waterbor, J W; Funkhouser, E; Terndrup, T E

    2007-01-01

    Dispatch-assisted chest compressions only CPR (CC-CPR) has gained widespread acceptance, and recent research suggests that increasing the proportion of compression time during CPR may increase survival from out-of-hospital cardiac arrest. We created a simplified CC-CPR protocol to reduce time to start chest compressions and to increase the proportion of time spent delivering chest compressions. This simplified protocol was compared to a published protocol, Medical Priority Dispatch System (MPDS) Version 11.2, recommended by the National Academies of Emergency Dispatch. Subjects were randomized to the MPDS v11.2 protocol or a simplified protocol. Data was recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions for both protocols. Outcomes included chest compression rate, depth, hand position, full release, overall proportion of compressions without error, time to start of CPR and total hands-off chest time. Proportions were analyzed by Wilcoxon's Rank Sum tests and time variables with Welch ANOVA and Wilcoxon's Rank Sum test. All tests used a two-sided alpha-level of 0.05. One hundred and seventeen subjects were randomized prospectively, 58 to the standard protocol and 59 to the simplified protocol. The average age of subjects in both groups was 25 years old. For both groups, the compression rate was equivalent (104 simplified versus 94 MPDS, p = 0.13), as was the proportion with total release (1.0 simplified versus 1.0 MPDS, p = 0.09). The proportion to the correct depth was greater in the simplified protocol (0.31 versus 0.03, p < 0.01), as was the proportion of compressions done without error (0.05 versus 0.0, p = 0.16). Time to start of chest compressions and total hands-off chest time were better in the simplified protocol (start time 60.9s versus 78.6s, p < 0.0001; hands-off chest time 69 s versus 95 s, p < 0.0001). The proportion with correct hand position, however, was worse in the simplified protocol (0.35 versus 0.84, p < 0.01). The simplified protocol was as good as, or better than the MPDS v11.2 protocol in every aspect studied except hand position, and the simplified protocol resulted in significant time savings. The protocol may need modification to ensure correct hand position. Time savings and improved quality of CPR achieved by the new set of instructions could be important in strengthening critical links in the cardiac chain of survival.

  4. CPR performance in the presence of audiovisual feedback or football shoulder pads.

    PubMed

    Tanaka, Shota; Rodrigues, Wayne; Sotir, Susan; Sagisaka, Ryo; Tanaka, Hideharu

    2017-01-01

    The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4-6.1) cm, 114(96-131) cpm; BLS-EMS: 5.4 (4.1-6.4) cm, 112(99-131) cpm; ACLS-EMS: 6.4 (5.7-6.7) cm, 138(113-140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9-49.2)% vs 69.6 (32.3-85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0-80.7)% without feedback to 59.2 (17.3-74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the presence of FSP (median (IQR), 22.0 (7.3-36.2)% vs 71.3 (35.4-86.5)%; p=0.0002). The use of audiovisual feedback positively affects the quality of the depth of CPR. Both feedback and FSP do not alter the rate measurements. Medically trained personnel are able to deliver the desired depth regardless of the presence of FSP even though shallower chest compressions depth can be seen in CPR with FSP. A feedback device must be introduced into the athletic training settings.

  5. CPR performance in the presence of audiovisual feedback or football shoulder pads

    PubMed Central

    Tanaka, Shota; Rodrigues, Wayne; Sotir, Susan; Sagisaka, Ryo; Tanaka, Hideharu

    2017-01-01

    Objective The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. Methods Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. Results CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4–6.1) cm, 114(96–131) cpm; BLS-EMS: 5.4 (4.1–6.4) cm, 112(99–131) cpm; ACLS-EMS: 6.4 (5.7–6.7) cm, 138(113–140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9–49.2)% vs 69.6 (32.3–85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0–80.7)% without feedback to 59.2 (17.3–74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the presence of FSP (median (IQR), 22.0 (7.3–36.2)% vs 71.3 (35.4–86.5)%; p=0.0002). Conclusions The use of audiovisual feedback positively affects the quality of the depth of CPR. Both feedback and FSP do not alter the rate measurements. Medically trained personnel are able to deliver the desired depth regardless of the presence of FSP even though shallower chest compressions depth can be seen in CPR with FSP. A feedback device must be introduced into the athletic training settings. PMID:28761704

  6. Improvement in Trainees' Attitude and Resuscitation Quality With Repeated Cardiopulmonary Resuscitation Training: Cross-Sectional Simulation Study.

    PubMed

    Kim, Jong Won; Lee, Jeong Hun; Lee, Kyeong Ryong; Hong, Dae Young; Baek, Kwang Je; Park, Sang O

    2016-08-01

    This study investigated the effect of increasing numbers of training sessions in cardiopulmonary resuscitation (CPR) on trainees' attitude and CPR quality. Cardiopulmonary resuscitation training for hospital employees was held every year from 2006 to 2010. Participants were recruited among the trainees in 2010. The trainees' attitudes toward CPR were surveyed by questionnaire, and the quality of their CPR was measured using 5-cycle 30:2 CPR on a manikin. Participants were categorized according to the number of consecutive CPR training sessions as T1 (only 2010), T2 (2009 and 2010), T3 (from 2008 to 2010) and T4-5 (from 2006 or 2007 to 2010). The trainee attitude and CPR quality were compared among the 4 groups. Of 923 CPR trainees, 267 were enrolled in the study. There was significant increase in willingness to start CPR and confidence in chest compression and mouth-to-mouth ventilation (MTMV) with increasing number of CPR training sessions attended (especially for ≥ 3 sessions). There was a significant increase in mean compression depth and decrease in percentage of chest compressions with depth of less than 38 mm in the T3 and T4-5 compared with the T1 and T2. No-flow time decreased significantly, and the percentage of MTMV with visible chest rise increased, as the number of training sessions increased. Repeated CPR training improved trainees' attitude and CPR quality. Because the number of training sessions increased (≥3), the willingness to start CPR and the confidence in skills increased significantly, and chest compression depth, no-flow time, and MTMV improved.

  7. Football Equipment Removal Improves Chest Compression and Ventilation Efficacy.

    PubMed

    Mihalik, Jason P; Lynall, Robert C; Fraser, Melissa A; Decoster, Laura C; De Maio, Valerie J; Patel, Amar P; Swartz, Erik E

    2016-01-01

    Airway access recommendations in potential catastrophic spine injury scenarios advocate for facemask removal, while keeping the helmet and shoulder pads in place for ensuing emergency transport. The anecdotal evidence to support these recommendations assumes that maintaining the helmet and shoulder pads assists inline cervical stabilization and that facial access guarantees adequate airway access. Our objective was to determine the effect of football equipment interference on performing chest compressions and delivering adequate ventilations on patient simulators. We hypothesized that conditions with more football equipment would decrease chest compression and ventilation efficacy. Thirty-two certified athletic trainers were block randomized to participate in six different compression conditions and six different ventilation conditions using human patient simulators. Data for chest compression (mean compression depth, compression rate, percentage of correctly released compressions, and percentage of adequate compressions) and ventilation (total ventilations, mean ventilation volume, and percentage of ventilations delivering adequate volume) conditions were analyzed across all conditions. The fully equipped athlete resulted in the lowest mean compression depth (F5,154 = 22.82; P < 0.001; Effect Size = 0.98) and delivery of adequate compressions (F5,154 = 15.06; P < 0.001; Effect Size = 1.09) compared to all other conditions. Bag-valve mask conditions resulted in delivery of significantly higher mean ventilation volumes compared to all 1- or 2-person pocketmask conditions (F5,150 = 40.05; P < 0.001; Effect Size = 1.47). Two-responder ventilation scenarios resulted in delivery of a greater number of total ventilations (F5,153 = 3.99; P = 0.002; Effect Size = 0.26) and percentage of adequate ventilations (F5,150 = 5.44; P < 0.001; Effect Size = 0.89) compared to one-responder scenarios. Non-chinstrap conditions permitted greater ventilation volumes (F3,28 = 35.17; P < 0.001; Effect Size = 1.78) and a greater percentage of adequate volume (F3,28 = 4.85; P = 0.008; Effect Size = 1.12) compared to conditions with the chinstrap buckled or with the chinstrap in place but not buckled. Chest compression and ventilation delivery are compromised in equipment-intense conditions when compared to conditions whereby equipment was mostly or entirely removed. Emergency medical personnel should remove the helmet and shoulder pads from all football athletes who require cardiopulmonary resuscitation, while maintaining appropriate cervical spine stabilization when injury is suspected. Further research is needed to confirm our findings supporting full equipment removal for chest compression and ventilation delivery.

  8. Mechanics of airway and alveolar collapse in human breath-hold diving.

    PubMed

    Fitz-Clarke, John R

    2007-11-15

    A computational model of the human respiratory tract was developed to study airway and alveolar compression and re-expansion during deep breath-hold dives. The model incorporates the chest wall, supraglottic airway, trachea, branched airway tree, and elastic alveoli assigned time-dependent surfactant properties. Total lung collapse with degassing of all alveoli is predicted to occur around 235 m, much deeper than estimates for aquatic mammals. Hysteresis of the pressure-volume loop increases with maximum diving depth due to progressive alveolar collapse. Reopening of alveoli occurs stochastically as airway pressure overcomes adhesive and compressive forces on ascent. Surface area for gas exchange vanishes at collapse depth, implying that the risk of decompression sickness should reach a plateau beyond this depth. Pulmonary capillary transmural stresses cannot increase after local alveolar collapse. Consolidation of lung parenchyma might provide protection from capillary injury or leakage caused by vascular engorgement due to outward chest wall recoil at extreme depths.

  9. The effects of music on the cardiac resuscitation education of nursing students.

    PubMed

    Tastan, Sevinc; Ayhan, Hatice; Unver, Vesile; Cinar, Fatma Ilknur; Kose, Gulsah; Basak, Tulay; Cinar, Orhan; Iyigun, Emine

    2017-03-01

    The purpose of this study is to examine the effects of music on the appropriate performance of the rate and depth of chest compression for nursing students. This randomized controlled study was conducted in the School of Nursing in Turkey between November 2014 and January 2015. The study's participants were second-year nursing school students with no previous formal cardiac resuscitation training (n=77). Participants were randomly assigned to one of two groups: an intervention group with music and a control group without music. During practical training, the intervention group performed chest compressions with music. The outcomes of this study were collected twice. The first evaluation was conducted one day after CPR education, and the second evaluation was conducted six weeks after the initial training. The first evaluation shows that the participants in the intervention group had an average rate of 107.33±7.29 chest compressions per minute, whereas the rate for the control group was 121.47±12.91. The second evaluation shows that the rates of chest compression for the intervention and control groups were 106.24±8.72 and 100.71±9.54, respectively. The results of this study show that a musical piece enables students to remember the ideal rhythm for chest compression. Performing chest compression with music can easily be integrated into CPR education because it does not require additional technology and is cheap. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. [Resuscitation - Basic Life Support in adults and application of automatic external defibrillators].

    PubMed

    Bohn, Andreas; Seewald, Stephan; Wnent, Jan

    2016-03-01

    Witnesses of a sudden cardiac arrest play a key-role in resuscitation. Lay-persons should therefore be trained to recognize that a collapsed person who is not breathing at all or breathing normally might suffer from cardiac arrest. Information of professional emergency medical staff by lay-persons and their initiation of cardio-pulmonary-resuscitation-measures are of great importance for cardiac-arrest victims. Ambulance-dispatchers have to support lay-rescuers via telephone. This support includes the localisation of the nearest Automatic External Defibrillator (AED). Presentation of agonal breathing or convulsions due to brain-hypoxia need to be recognized as potential early signs of cardiac arrest. In any case of cardiac arrest chest-compressions need to be started. There is insufficiant data to recommend "chest-compression-only"-CPR as being equally sufficient as cardio-pulmonary-resuscitation including ventilation. Rescuers trained in ventilation should therefore combine compressions and ventilations at a 30:2-ratio. Movement of the chest is being used as a sign of sufficient ventilation. High-quality chest-compressions of at least 5 cm of depth, not exceeding 6 cm, are recommended at a ratio of 100-120 chest conpressions/min. Interruption of chest-compression should be avoided. At busy public places AED should be available to enable lay-rescuers to apply early defibrillation. © Georg Thieme Verlag Stuttgart · New York.

  11. Effectiveness of a simplified cardiopulmonary resuscitation training program for the non-medical staff of a university hospital.

    PubMed

    Hirose, Tomoya; Iwami, Taku; Ogura, Hiroshi; Matsumoto, Hisatake; Sakai, Tomohiko; Yamamoto, Kouji; Mano, Toshiaki; Fujino, Yuji; Shimazu, Takeshi

    2014-05-10

    The 2010 Consensus on Science and Treatment Recommendations Statement recommended that short video/computer self-instruction courses, with minimal or no instructor coaching, combined with hands-on practice can be considered an effective alternative to instructor-led basic life support courses. The purpose of this study was to examine the effectiveness of a simplified cardiopulmonary resuscitation (CPR) training program for non-medical staff working at a university hospital. Before and immediately after a 45-min CPR training program consisting of instruction on chest compression and automated external defibrillator (AED) use with a personal training manikin, CPR skills were automatically recorded and evaluated. Participants' attitudes towards CPR were evaluated by a questionnaire survey. From September 2011 through March 2013, 161 participants attended the program. We evaluated chest compression technique in 109 of these participants. The number of chest compressions delivered after the program versus that before was significantly greater (110.8 ± 13.0/min vs 94.2 ± 27.4/min, p < 0.0001), interruption of chest compressions was significantly shorter (0.05 ± 0.34 sec/30 sec vs 0.89 ± 3.52 sec/30 sec, p < 0.05), mean depth of chest compressions was significantly greater (57.6 ± 6.8 mm vs 52.2 ± 9.4 mm, p < 0.0001), and the proportion of incomplete chest compressions of <5 cm among all chest compressions was significantly decreased (8.9 ± 23.2% vs 38.6 ± 42.9%, p < 0.0001). Of the 159 participants who responded to the questionnaire survey after the program, the proportion of participants who answered 'I can check for a response,' 'I can perform chest compressions,' and 'I can absolutely or I think I can use an AED' increased versus that before the program (81.8% vs 19.5%, 77.4% vs 10.1%, 84.3% vs 23.3%, respectively). A 45-min simplified CPR training program on chest compression and AED use improved CPR quality and the attitude towards CPR and AED use of non-medical staff of a university hospital.

  12. Bystander fatigue and CPR quality by older bystanders: a randomized crossover trial comparing continuous chest compressions and 30:2 compressions to ventilations.

    PubMed

    Liu, Shawn; Vaillancourt, Christian; Kasaboski, Ann; Taljaard, Monica

    2016-11-01

    This study sought to measure bystander fatigue and cardiopulmonary resuscitation (CPR) quality after five minutes of CPR using the continuous chest compression (CCC) versus the 30:2 chest compression to ventilation method in older lay persons, a population most likely to perform CPR on cardiac arrest victims. This randomized crossover trial took place at three tertiary care hospitals and a seniors' center. Participants were aged ≥55 years without significant physical limitations (frailty score ≤3/7). They completed two 5-minute CPR sessions (using 30:2 and CCC) on manikins; sessions were separated by a rest period. We used concealed block randomization to determine CPR method order. Metronome feedback maintained a compression rate of 100/minute. We measured heart rate (HR), mean arterial pressure (MAP), and Borg Exertion Scale. CPR quality measures included total number of compressions and number of adequate compressions (depth ≥5 cm). Sixty-three participants were enrolled: mean age 70.8 years, female 66.7%, past CPR training 60.3%. Bystander fatigue was similar between CPR methods: mean difference in HR -0.59 (95% CI -3.51-2.33), MAP 1.64 (95% CI -0.23-3.50), and Borg 0.46 (95% CI 0.07-0.84). Compared to 30:2, participants using CCC performed more chest compressions (480.0 v. 376.3, mean difference 107.7; p<0.0001) and more adequate chest compressions (381.5 v. 324.9, mean difference. 62.0; p=0.0001), although good compressions/minute declined significantly faster with the CCC method (p=0.0002). CPR quality decreased significantly faster when performing CCC compared to 30:2. However, performing CCC produced more adequate compressions overall with a similar level of fatigue compared to the 30:2 method.

  13. Suppression of the cardiopulmonary resuscitation artefacts using the instantaneous chest compression rate extracted from the thoracic impedance.

    PubMed

    Aramendi, E; Ayala, U; Irusta, U; Alonso, E; Eftestøl, T; Kramer-Johansen, J

    2012-06-01

    To demonstrate that the instantaneous chest compression rate can be accurately estimated from the transthoracic impedance (TTI), and that this estimated rate can be used in a method to suppress cardiopulmonary resuscitation (CPR) artefacts. A database of 372 records, 87 shockable and 285 non-shockable, from out-of-hospital cardiac arrest episodes, corrupted by CPR artefacts, was analysed. Each record contained the ECG and TTI obtained from the defibrillation pads and the compression depth (CD) obtained from a sternal CPR pad. The chest compression rates estimated using TTI and CD were compared. The CPR artefacts were then filtered using the instantaneous chest compression rates estimated from the TTI or CD signals. The filtering results were assessed in terms of the sensitivity and specificity of the shock advice algorithm of a commercial automated external defibrillator. The correlation between the mean chest compression rates estimated using TTI or CD was r=0.98 (95% confidence interval, 0.97-0.98). The sensitivity and specificity after filtering using CD were 95.4% (88.4-98.6%) and 87.0% (82.6-90.5%), respectively. The sensitivity and specificity after filtering using TTI were 95.4% (88.4-98.6%) and 86.3% (81.8-89.9%), respectively. The instantaneous chest compression rate can be accurately estimated from TTI. The sensitivity and specificity after filtering are similar to those obtained using the CD signal. Our CPR suppression method based exclusively on signals acquired through the defibrillation pads is as accurate as methods based on signals obtained from CPR feedback devices. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Cardiopulmonary Resuscitation in Lunar and Martian Gravity Fields

    NASA Technical Reports Server (NTRS)

    Sarkar, Subhajit

    2004-01-01

    Cardiopulmonary resuscitation is required training for all astronauts. No studies thus far have investigated how chest compressions may be affected in lunar and Martian gravities. Therefore a theoretical quantitative study was performed. The maximum downward force an unrestrained person can apply is mg N (g(sub Earth) = 9.78 ms(sup -2), g(sub moon) = 1.63 ms(sup -2), g(sub Mars) = 3.69 ms(sup -2). Tsitlik et a1 (Critical Care Medicine, 1983) described the human sternal elastic force-displacement relationship (compliance) by: F = betaD(sub s) + gammaD(sub s)(sup 2) (beta = 54.9 plus or minus 29.4 Ncm(sup -1) and gamma = 10.8 plus or minus 4.1 Ncm(sup -2)). Maximum forces in the 3 gravitational fields produced by 76 kg (US population mean), 41 kg and 93 kg (masses derived from the limits for astronaut height), produced solutions for compression depth using Tsitlik equations for chests of: mean compliance (beta = 54.9, gamma = 10.8), low compliance (beta = 84.3, gamma = 14.9) and high compliance (beta = 25.5, gamma = 6.7). The mass for minimum adequate adult compression, 3.8 cm (AHA guidelines), was also calculated. 76 kg compresses the mean compliance chest by: Earth, 6.1 cm, Mars, 3.2 cm, Moon, 1.7 cm. In lunar gravity, the high compliance chest is compressed only 3.2 cm by 93 kg, 120 kg being required for 3.8 cm. In Martian gravity, on the mean chest, 93 kg compresses 3.6 cm; 99 kg is required for 3.8 cm. On Mars, the high compliance chest is compressed 4.8 cm with 76 kg, 5.5 cm with 93 kg, with 52 kg required for 3.8 cm.

  15. [Effects of a voice metronome on compression rate and depth in telephone assisted, bystander cardiopulmonary resuscitation: an investigator-blinded, 3-armed, randomized, simulation trial].

    PubMed

    van Tulder, Raphael; Roth, Dominik; Krammel, Mario; Laggner, Roberta; Schriefl, Christoph; Kienbacher, Calvin; Lorenzo Hartmann, Alexander; Novosad, Heinz; Constantin Chwojka, Christof; Havel, Christoph; Schreiber, Wolfgang; Herkner, Harald

    2015-01-01

    We investigated the effect on compression rate and depth of a conventional metronome and a voice metronome in simulated telephone-assisted, protocol-driven bystander Cardiopulmonary resucitation (CPR) compared to standard instruction. Thirty-six lay volunteers performed 10 minutes of compression-only CPR in a prospective, investigator-blinded, 3-arm study on a manikin. Participants were randomized either to standard instruction ("push down firmly, 5 cm"), a regular metronome pacing 110 beats per minute (bpm), or a voice metronome continuously prompting "deep-deepdeep- deeper" at 110 bpm. The primary outcome was deviation from the ideal chest compression target range (50 mm compression depth x 100 compressions per minute x 10 minutes = 50 m). Secondary outcomes were CPR quality measures (compression and leaning depth, rate, no-flow times) and participants' related physiological response (heart rate, blood pressure and nine hole peg test and borg scales score). We used a linear regression model to calculate effects. The mean (SD) deviation from the ideal target range (50 m) was -11 (9) m in the standard group, -20 (11) m in the conventional metronome group (adjusted difference [95%, CI], 9.0 [1.2-17.5 m], P=.03), and -18 (9) m in the voice metronome group (adjusted difference, 7.2 [-0.9-15.3] m, P=.08). Secondary outcomes (CPR quality measures and physiological response of participants to CPR performance) showed no significant differences. Compared to standard instruction, the conventional metronome showed a significant negative effect on the chest compression target range. The voice metronome showed a non-significant negative effect and therefore cannot be recommended for regular use in telephone-assisted CPR.

  16. Effectiveness of a simplified cardiopulmonary resuscitation training program for the non-medical staff of a university hospital

    PubMed Central

    2014-01-01

    Background The 2010 Consensus on Science and Treatment Recommendations Statement recommended that short video/computer self-instruction courses, with minimal or no instructor coaching, combined with hands-on practice can be considered an effective alternative to instructor-led basic life support courses. The purpose of this study was to examine the effectiveness of a simplified cardiopulmonary resuscitation (CPR) training program for non-medical staff working at a university hospital. Methods Before and immediately after a 45-min CPR training program consisting of instruction on chest compression and automated external defibrillator (AED) use with a personal training manikin, CPR skills were automatically recorded and evaluated. Participants’ attitudes towards CPR were evaluated by a questionnaire survey. Results From September 2011 through March 2013, 161 participants attended the program. We evaluated chest compression technique in 109 of these participants. The number of chest compressions delivered after the program versus that before was significantly greater (110.8 ± 13.0/min vs 94.2 ± 27.4/min, p < 0.0001), interruption of chest compressions was significantly shorter (0.05 ± 0.34 sec/30 sec vs 0.89 ± 3.52 sec/30 sec, p < 0.05), mean depth of chest compressions was significantly greater (57.6 ± 6.8 mm vs 52.2 ± 9.4 mm, p < 0.0001), and the proportion of incomplete chest compressions of <5 cm among all chest compressions was significantly decreased (8.9 ± 23.2% vs 38.6 ± 42.9%, p < 0.0001). Of the 159 participants who responded to the questionnaire survey after the program, the proportion of participants who answered ‘I can check for a response,’ ‘I can perform chest compressions,’ and ‘I can absolutely or I think I can use an AED’ increased versus that before the program (81.8% vs 19.5%, 77.4% vs 10.1%, 84.3% vs 23.3%, respectively). Conclusions A 45-min simplified CPR training program on chest compression and AED use improved CPR quality and the attitude towards CPR and AED use of non-medical staff of a university hospital. PMID:24887037

  17. The specific effect of metronome guidance on the quality of one-person cardiopulmonary resuscitation and rescuer fatigue.

    PubMed

    Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Cho, Young Soon; Chung, Sung Phil; Park, Incheol; Kim, Seung Ho

    2012-12-01

    Metronome guidance is a simple and economic feedback method of guiding cardiopulmonary resuscitation (CPR). It has been proven for its usefulness in regulating the rate of chest compression and ventilation, but it is not yet clear how metronome use may affect compression depth or rescuer fatigue. The aim of this study was to assess the specific effect that metronome guidance has on the quality of CPR and rescuer fatigue. One-person CPRs were performed by senior medical students on Resusci Anne® manikins (Laerdal, Stavanger, Norway) with personal-computer skill-reporting systems. Half of the students performed CPR with metronome guidance and the other half without. CPR performance data, duration, and before-after trial differences in mean arterial pressure (MAP) and heart rate (HR) were compared between groups. Average compression depth (ACD) of the first five cycles, compression rate, no-flow fraction, and ventilation count were significantly lower in the metronome group (p=0.028, < 0.001, 0.001, and 0.041, respectively). Total CPR duration, total work (ACD × total compression count), and the before-after trial differences of the MAP and HR did not differ between the two groups. Metronome guidance is associated with lower chest compression depth of the first five cycles, while shortening the no-flow fraction and the ventilation count in a simulated one-person CPR model. Metronome guidance does not have an obvious effect of intensifying rescuer fatigue. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Quality of cardio-pulmonary resuscitation (CPR) during paediatric resuscitation training: time to stop the blind leading the blind.

    PubMed

    Arshid, Muhammad; Lo, Tsz-Yan Milly; Reynolds, Fiona

    2009-05-01

    Recent evidence suggested that the quality of cardio-pulmonary resuscitation (CPR) during adult advanced life support training was suboptimal. This study aimed to assess the CPR quality of a paediatric resuscitation training programme, and to determine whether it was sufficiently addressed by the trainee team leaders during training. CPR quality of 20 consecutive resuscitation scenario training sessions was audited prospectively using a pre-designed proforma. A consultant intensivist and a senior nurse who were also Advanced Paediatric Life Support (APLS) instructors assessed the CPR quality which included ventilation frequency, chest compression rate and depth, and any unnecessary interruption in chest compressions. Team leaders' response to CPR quality and elective change of compression rescuer during training were also recorded. Airway patency was not assessed in 13 sessions while ventilation rate was too fast in 18 sessions. Target compression rate was not achieved in only 1 session. The median chest compression rate was 115 beats/min. Chest compressions were too shallow in 10 sessions and were interrupted unnecessarily in 13 sessions. More than 50% of training sessions did not have elective change of the compression rescuer. 19 team leaders failed to address CPR quality during training despite all team leaders being certified APLS providers. The quality of CPR performance was suboptimal during paediatric resuscitation training and team leaders-in-training had little awareness of this inadequacy. Detailed CPR quality assessment and feedback should be integrated into paediatric resuscitation training to ensure optimal performance in real life resuscitations.

  19. The effect of strength training on quality of prolonged basic cardiopulmonary resuscitation.

    PubMed

    Abelairas-Gómez, Cristian; Barcala-Furelos, Roberto; Szarpak, Łukasz; García-García, Óscar; Paz-Domínguez, Álvaro; López-García, Sergio; Rodríguez-Núñez, Antonio

    2017-01-01

    Providing high-quality chest compressions and rescue breaths are key elements in the effectiveness of cardio-pulmonary resuscitation. To investigate the effects of a strength training programme on the quality of prolonged basic cardiopulmonary resuscitation on a manikin. This was a quasi-experimental trial. Thirty-nine participants with prior basic life support knowledge were randomised to an experimental or control group. They then performed a test of 10 min of chest compressions and mouth-to-mouth ventilation on manikins equipped with a skill reporter tool (baseline or test 1). The experimental group participated in a four-week strength training programme focused on the muscles involved in chest compressions. Both groups were subsequently tested again (test 2). After training, the experimental group significantly increased the mean depth of compression (53.7 ± 2.3 mm vs. 49.9 ± 5.9 mm; p = 0.003) and the correct compression fraction (68.2 ± 21.0% vs. 46.4 ± 29.1%; p = 0.004). Trained subjects maintained chest compression quality over time better than the control group. The mean tidal volume delivered was higher in the experimental than in the control group (701.5 ± 187.0 mL vs. 584.8 ± 113.6 mL; p = 0.040) and above the current resuscitation guidelines. In test 2, the percentage of rescue breaths with excessive volume was higher in the experi-mental group than in the controls (31.5 ± 19.6% vs. 15.6 ± 13.0%; p = 0.007). A simple strength training programme has a significant impact on the quality of chest compressions and its maintenance over time. Additional training is needed to avoid over-ventilation of potential patients.

  20. Cardiopulmonary resuscitation by chest compression alone or with mouth-to-mouth ventilation.

    PubMed

    Hallstrom, A; Cobb, L; Johnson, E; Copass, M

    2000-05-25

    Despite extensive training of citizens of Seattle in cardiopulmonary resuscitation (CPR), bystanders do not perform CPR in almost half of witnessed cardiac arrests. Instructions in chest compression plus mouth-to-mouth ventilation given by dispatchers over the telephone can require 2.4 minutes. In experimental studies, chest compression alone is associated with survival rates similar to those with chest compression plus mouth-to-mouth ventilation. We conducted a randomized study to compare CPR by chest compression alone with CPR by chest compression plus mouth-to-mouth ventilation. The setting of the trial was an urban, fire-department-based, emergency-medical-care system with central dispatching. In a randomized manner, telephone dispatchers gave bystanders at the scene of apparent cardiac arrest instructions in either chest compression alone or chest compression plus mouth-to-mouth ventilation. The primary end point was survival to hospital discharge. Data were analyzed for 241 patients randomly assigned to receive chest compression alone and 279 assigned to chest compression plus mouth-to-mouth ventilation. Complete instructions were delivered in 62 percent of episodes for the group receiving chest compression plus mouth-to-mouth ventilation and 81 percent of episodes for the group receiving chest compression alone (P=0.005). Instructions for compression required 1.4 minutes less to complete than instructions for compression plus mouth-to-mouth ventilation. Survival to hospital discharge was better among patients assigned to chest compression alone than among those assigned to chest compression plus mouth-to-mouth ventilation (14.6 percent vs. 10.4 percent), but the difference was not statistically significant (P=0.18). The outcome after CPR with chest compression alone is similar to that after chest compression with mouth-to-mouth ventilation, and chest compression alone may be the preferred approach for bystanders inexperienced in CPR.

  1. The Efficacy of LUCAS in Prehospital Cardiac Arrest Scenarios: A Crossover Mannequin Study.

    PubMed

    Gyory, Robert A; Buchle, Scott E; Rodgers, David; Lubin, Jeffrey S

    2017-04-01

    High-quality cardiopulmonary resuscitation (CPR) is critical for successful cardiac arrest outcomes. Mechanical devices may improve CPR quality. We simulated a prehospital cardiac arrest, including patient transport, and compared the performance of the LUCAS™ device, a mechanical chest compression-decompression system, to manual CPR. We hypothesized that because of the movement involved in transporting the patient, LUCAS would provide chest compressions more consistent with high-quality CPR guidelines. We performed a crossover-controlled study in which a recording mannequin was placed on the second floor of a building. An emergency medical services (EMS) crew responded, defibrillated, and provided either manual or LUCAS CPR. The team transported the mannequin through hallways and down stairs to an ambulance and drove to the hospital with CPR in progress. Critical events were manually timed while the mannequin recorded data on compressions. Twenty-three EMS providers participated. Median time to defibrillation was not different for LUCAS compared to manual CPR (p=0.97). LUCAS had a lower median number of compressions per minute (112/min vs. 125/min; IQR = 102-128 and 102-126 respectively; p<0.002), which was more consistent with current American Heart Association CPR guidelines, and percent adequate compression rate (71% vs. 40%; IQR = 21-93 and 12-88 respectively; p<0.002). In addition, LUCAS had a higher percent adequate depth (52% vs. 36%; IQR = 25-64 and 29-39 respectively; p<0.007) and lower percent total hands-off time (15% vs. 20%; IQR = 10-22 and 15-27 respectively; p<0.005). LUCAS performed no differently than manual CPR in median compression release depth, percent fully released compressions, median time hands off, or percent correct hand position. In our simulation, LUCAS had a higher rate of adequate compressions and decreased total hands-off time as compared to manual CPR. Chest compression quality may be better when using a mechanical device during patient movement in prehospital cardiac arrest patient.

  2. Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs.

    PubMed

    Pytte, Morten; Kramer-Johansen, Jo; Eilevstjønn, Joar; Eriksen, Morten; Strømme, Taevje A; Godang, Kristin; Wik, Lars; Steen, Petter Andreas; Sunde, Kjetil

    2006-12-01

    Adrenaline (epinephrine) is used during cardiopulmonary resuscitation (CPR) based on animal experiments without supportive clinical data. Clinically CPR was reported recently to have much poorer quality than expected from international guidelines and what is generally done in laboratory experiments. We have studied the haemodynamic effects of adrenaline during CPR with good laboratory quality and with quality simulating clinical findings and the feasibility of monitoring these effects through VF waveform analysis. After 4 min of cardiac arrest, followed by 4 min of basic life support, 14 pigs were randomised to ClinicalCPR (intermittent manual chest compressions, compression-to-ventilation ratio 15:2, compression depth 30-38 mm) or LabCPR (continuous mechanical chest compressions, 12 ventilations/min, compression depth 45 mm). Adrenaline 0.02 mg/kg was administered 30 s thereafter. Plasma adrenaline concentration peaked earlier with LabCPR than with ClinicalCPR, median (range), 90 (30, 150) versus 150 (90, 270) s (p = 0.007), respectively. Coronary perfusion pressure (CPP) and cortical cerebral blood flow (CCBF) increased and femoral blood flow (FBF) decreased after adrenaline during LabCPR (mean differences (95% CI) CPP 17 (6, 29) mmHg (p = 0.01), FBF -5.0 (-8.8, -1.2) ml min(-1) (p = 0.02) and median difference CCBF 12% of baseline (p = 0.04)). There were no significant effects during ClinicalCPR (mean differences (95% CI) CPP 4.7 (-3.2, 13) mmHg (p = 0.2), FBF -0.2 (-4.6, 4.2) ml min(-1)(p = 0.9) and CCBF 3.6 (-1.8, 9.0)% of baseline (p = 0.15)). Slope VF waveform analysis reflected changes in CPP. Adrenaline improved haemodynamics during laboratory quality CPR in pigs, but not with quality simulating clinically reported CPR performance.

  3. Interdisciplinary ICU Cardiac Arrest Debriefing Improves Survival Outcomes

    PubMed Central

    Wolfe, Heather; Zebuhr, Carleen; Topjian, Alexis A.; Nishisaki, Akira; Niles, Dana E.; Meaney, Peter A.; Boyle, Lori; Giordano, Rita T.; Davis, Daniela; Priestley, Margaret; Apkon, Michael; Berg, Robert A.; Nadkarni, Vinay M.; Sutton, Robert M.

    2014-01-01

    Objective In-hospital cardiac arrest is an important public health problem. High-quality resuscitation improves survival but is difficult to achieve. Our objective is to evaluate the effectiveness of a novel, interdisciplinary, postevent quantitative debriefing program to improve survival outcomes after in-hospital pediatric chest compression events. Design, Setting, and Patients Single-center prospective interventional study of children who received chest compressions between December 2008 and June 2012 in the ICU. Interventions Structured, quantitative, audiovisual, interdisciplinary debriefing of chest compression events with front-line providers. Measurements and Main Results Primary outcome was survival to hospital discharge. Secondary outcomes included survival of event (return of spontaneous circulation for ≥ 20 min) and favorable neurologic outcome. Primary resuscitation quality outcome was a composite variable, termed “excellent cardiopulmonary resuscitation,” prospectively defined as a chest compression depth ≥ 38 mm, rate ≥ 100/min, ≤ 10% of chest compressions with leaning, and a chest compression fraction > 90% during a given 30-second epoch. Quantitative data were available only for patients who are 8 years old or older. There were 119 chest compression events (60 control and 59 interventional). The intervention was associated with a trend toward improved survival to hospital discharge on both univariate analysis (52% vs 33%, p = 0.054) and after controlling for confounders (adjusted odds ratio, 2.5; 95% CI, 0.91–6.8; p = 0.075), and it significantly increased survival with favorable neurologic outcome on both univariate (50% vs 29%, p = 0.036) and multivariable analyses (adjusted odds ratio, 2.75; 95% CI, 1.01–7.5; p = 0.047). Cardiopulmonary resuscitation epochs for patients who are 8 years old or older during the debriefing period were 5.6 times more likely to meet targets of excellent cardiopulmonary resuscitation (95% CI, 2.9–10.6; p < 0.01). Conclusion Implementation of an interdisciplinary, postevent quantitative debriefing program was significantly associated with improved cardiopulmonary resuscitation quality and survival with favorable neurologic outcome. (Crit Care Med 2014; XX:00–00) PMID:24717462

  4. Development of a smart backboard system for real-time feedback during CPR chest compression on a soft back support surface.

    PubMed

    Gohier, Francis; Dellimore, Kiran; Scheffer, Cornie

    2013-01-01

    The quality of cardiopulmonary resuscitation (CPR) is often inconsistent and frequently fails to meet recommended guidelines. One promising approach to address this problem is for clinicians to use an active feedback device during CPR. However, one major deficiency of existing feedback systems is that they fail to account for the displacement of the back support surface during chest compression (CC), which can be important when CPR is performed on a soft surface. In this study we present the development of a real-time CPR feedback system based on an algorithm which uses force and dual-accelerometer measurements to provide accurate estimation of the CC depth on a soft surface, without assuming full chest decompression. Based on adult CPR manikin tests it was found that the accuracy of the estimated CC depth for a dual accelerometer feedback system is significantly better (7.3% vs. 24.4%) than for a single accelerometer system on soft back support surfaces, in the absence or presence of a backboard. In conclusion, the algorithm used was found to be suitable for a real-time, dual accelerometer CPR feedback application since it yielded reasonable accuracy in terms of CC depth estimation, even when used on a soft back support surface.

  5. Relative effectiveness of dominant versus non-dominant hand position for rescuer's side of approach during chest compressions between right-handed and left-handed novice rescuers.

    PubMed

    You, Je Sung; Kim, Hoon; Park, Jung Soo; Baek, Kyung Min; Jang, Mun Sun; Lee, Hye Sun; Chung, Sung Phil; Kim, SeungWhan

    2015-03-01

    The major components affecting high quality cardiopulmonary resuscitation (CPR) have been defined as the ability of the rescuer, hand position, position of the rescuer and victim, depth and rate of chest compressions, and fatigue. Until now, there have been no studies on dominant versus non-dominant hand position and the rescuer's side of approach. This study was designed to evaluate the effectiveness of hand position and approach side on the quality of CPR between right-handed (RH) and left-handed (LH) novice rescuers. 44 health science university students with no previous experience of basic life support (BLS) volunteered for the study. We divided volunteers into two groups by handedness. Adult BLS was performed on a manikin for 2 min in each session. The sequences were randomly performed on the manikin's left side of approach (Lap) with the rescuer's left hand in contact with the sternum (Lst), Lap/Rst, Rap/Lst and Rap/Rst. We compared the quality of chest compressions between the RH and LH groups according to predetermined positions. A significant decrease in mean compression depth between the two groups was only observed when rescuers performed in the Rap/Lst scenario, regardless of hand dominance. The frequency of correct hand placement also significantly decreased in the Lap/Rst position for the LH group. The performance of novice rescuers during chest compressions is influenced by the position of the dominant hand and the rescuer's side of approach. In CPR training and real world situations, a novice rescuer, regardless of handedness, should consider hand positions for contacting the sternum identical to the side of approach after approaching from the nearest and most accessible side, for optimal CPR performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Effect of socioemotional stress on the quality of cardiopulmonary resuscitation during advanced life support in a randomized manikin study.

    PubMed

    Bjørshol, Conrad Arnfinn; Myklebust, Helge; Nilsen, Kjetil Lønne; Hoff, Thomas; Bjørkli, Cato; Illguth, Eirik; Søreide, Eldar; Sunde, Kjetil

    2011-02-01

    The aim of this study was to evaluate whether socioemotional stress affects the quality of cardiopulmonary resuscitation during advanced life support in a simulated manikin model. A randomized crossover trial with advanced life support performed in two different conditions, with and without exposure to socioemotional stress. The study was conducted at the Stavanger Acute Medicine Foundation for Education and Research simulation center, Stavanger, Norway. Paramedic teams, each consisting of two paramedics and one assistant, employed at Stavanger University Hospital, Stavanger, Norway. A total of 19 paramedic teams performed advanced life support twice in a randomized fashion, one control condition without socioemotional stress and one experimental condition with exposure to socioemotional stress. The socioemotional stress consisted of an upset friend of the simulated patient who was a physician, spoke a foreign language, was unfamiliar with current Norwegian resuscitation guidelines, supplied irrelevant clinical information, and repeatedly made doubts about the paramedics' resuscitation efforts. Aural distractions were supplied by television and cell telephone. The primary outcome was the quality of cardiopulmonary resuscitation: chest compression depth, chest compression rate, time without chest compressions (no-flow ratio), and ventilation rate after endotracheal intubation. As a secondary outcome, the socioemotional stress impact was evaluated through the paramedics' subjective workload, frustration, and feeling of realism. There were no significant differences in chest compression depth (39 vs. 38 mm, p = .214), compression rate (113 vs. 116 min⁻¹, p = .065), no-flow ratio (0.15 vs. 0.15, p = .618), or ventilation rate (8.2 vs. 7.7 min⁻¹, p = .120) between the two conditions. There was a significant increase in the subjective workload, frustration, and feeling of realism when the paramedics were exposed to socioemotional stress. In this advanced life support manikin study, the presence of socioemotional stress increased the subjective workload, frustration, and feeling of realism, without affecting the quality of cardiopulmonary resuscitation.

  7. Reducing the impact of intensive care unit mattress compressibility during CPR: a simulation-based study.

    PubMed

    Lin, Yiqun; Wan, Brandi; Belanger, Claudia; Hecker, Kent; Gilfoyle, Elaine; Davidson, Jennifer; Cheng, Adam

    2017-01-01

    The depth of chest compression (CC) during cardiac arrest is associated with patient survival and good neurological outcomes. Previous studies showed that mattress compression can alter the amount of CCs given with adequate depth. We aim to quantify the amount of mattress compressibility on two types of ICU mattresses and explore the effect of memory foam mattress use and a backboard on mattress compression depth and effect of feedback source on effective compression depth. The study utilizes a cross-sectional self-control study design. Participants working in the pediatric intensive care unit (PICU) performed 1 min of CC on a manikin in each of the following four conditions: (i) typical ICU mattress; (ii) typical ICU mattress with a CPR backboard; (iii) memory foam ICU mattress; and (iv) memory foam ICU mattress with a CPR backboard, using two different sources of real-time feedback: (a) external accelerometer sensor device measuring total compression depth and (b) internal light sensor measuring effective compression depth only. CPR quality was concurrently measured by these two devices. The differences of the two measures (mattress compression depth) were summarized and compared using multilevel linear regression models. Effective compression depths with different sources of feedback were compared with a multilevel linear regression model. The mean mattress compression depth varied from 24.6 to 47.7 mm, with percentage of depletion from 31.2 to 47.5%. Both use of memory foam mattress (mean difference, MD 11.7 mm, 95%CI 4.8-18.5 mm) and use of backboard (MD 11.6 mm, 95% CI 9.0-14.3 mm) significantly minimized the mattress compressibility. Use of internal light sensor as source of feedback improved effective CC depth by 7-14 mm, compared with external accelerometer sensor. Use of a memory foam mattress and CPR backboard minimizes mattress compressibility, but depletion of compression depth is still substantial. A feedback device measuring sternum-to-spine displacement can significantly improve effective compression depth on a mattress. Not applicable. This is a mannequin-based simulation research.

  8. Quality of closed chest compression on a manikin in ambulance vehicles and flying helicopters with a real time automated feedback.

    PubMed

    Havel, Christof; Schreiber, Wolfgang; Trimmel, Helmut; Malzer, Reinhard; Haugk, Moritz; Richling, Nina; Riedmüller, Eva; Sterz, Fritz; Herkner, Harald

    2010-01-01

    Automated verbal and visual feedback improves quality of resuscitation in out-of-hospital cardiac arrest and was proven to increase short-term survival. Quality of resuscitation may be hampered in more difficult situations like emergency transportation. Currently there is no evidence if feedback devices can improve resuscitation quality during different modes of transportation. To assess the effect of real time automated feedback on the quality of resuscitation in an emergency transportation setting. Randomised cross-over trial. Medical University of Vienna, Vienna Municipal Ambulance Service and Helicopter Emergency Medical Service Unit (Christophorus Flugrettungsverein) in September 2007. European Resuscitation Council (ERC) certified health care professionals performing CPR in a flying helicopter and in a moving ambulance vehicle on a manikin with human-like chest properties. CPR sessions, with real time automated feedback as the intervention and standard CPR without feedback as control. Quality of chest compression during resuscitation. Feedback resulted in less deviation from ideal compression rate 100 min(-1) (9+/-9 min(-1), p<0.0001) with this effect becoming steadily larger over time. Applied work was less in the feedback group compared to controls (373+/-448 cm x compression; p<0.001). Feedback did not influence ideal compression depth significantly. There was some indication of a learning effect of the feedback device. Real time automated feedback improves certain aspects of CPR quality in flying helicopters and moving ambulance vehicles. The effect of feedback guidance was most pronounced for chest compression rate. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  9. Advances in clinical studies of cardiopulmonary resuscitation

    PubMed Central

    Chen, Shou-quan

    2015-01-01

    BACKGROUND: The survival rate of patients after cardiac arrest (CA) remains lower since 2010 International Consensus on Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care (ECC) was published. In clinical trials, the methods and techniques for CPR have been overly described. This article gives an overview of the progress in methods and techniques for CPR in the past years. DATA SOURCES: Original articles about cardiac arrest and CPR from MEDLINE (PubMed) and relevant journals were searched, and most of them were clinical randomized controlled trials (RCTs). RESULTS: Forty-two articles on methods and techniques of CPR were reviewed, including chest compression and conventional CPR, chest compression depth and speed, defibrillation strategies and priority, mechanical and manual chest compression, advanced airway management, impedance threshold device (ITD) and active compression-decompression (ACD) CPR, epinephrine use, and therapeutic hypothermia. The results of studies and related issues described in the international guidelines had been testified. CONCLUSIONS: Although large multicenter studies on CPR are still difficult to carry out, progress has been made in the past 4 years in the methods and techniques of CPR. The results of this review provide evidences for updating the 2015 international guidelines. PMID:26056537

  10. Real-Time Mobile Device-Assisted Chest Compression During Cardiopulmonary Resuscitation.

    PubMed

    Sarma, Satyam; Bucuti, Hakiza; Chitnis, Anurag; Klacman, Alex; Dantu, Ram

    2017-07-15

    Prompt administration of high-quality cardiopulmonary resuscitation (CPR) is a key determinant of survival from cardiac arrest. Strategies to improve CPR quality at point of care could improve resuscitation outcomes. We tested whether a low cost and scalable mobile phone- or smart watch-based solution could provide accurate measures of compression depth and rate during simulated CPR. Fifty health care providers (58% intensive care unit nurses) performed simulated CPR on a calibrated training manikin (Resusci Anne, Laerdal) while wearing both devices. Subjects received real-time audiovisual feedback from each device sequentially. Primary outcome was accuracy of compression depth and rate compared with the calibrated training manikin. Secondary outcome was improvement in CPR quality as defined by meeting both guideline-recommend compression depth (5 to 6 cm) and rate (100 to 120/minute). Compared with the training manikin, typical error for compression depth was <5 mm (smart phone 4.6 mm; 95% CI 4.1 to 5.3 mm; smart watch 4.3 mm; 95% CI 3.8 to 5.0 mm). Compression rates were similarly accurate (smart phone Pearson's R = 0.93; smart watch R = 0.97). There was no difference in improved CPR quality defined as the number of sessions meeting both guideline-recommended compression depth (50 to 60 mm) and rate (100 to 120 compressions/minute) with mobile device feedback (60% vs 50%; p = 0.3). Sessions that did not meet guideline recommendations failed primarily because of inadequate compression depth (46 ± 2 mm). In conclusion, a mobile device application-guided CPR can accurately track compression depth and rate during simulation in a practice environment in accordance with resuscitation guidelines. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Training a Chest Compression of 6-7 cm Depth for High Quality Cardiopulmonary Resuscitation in Hospital Setting: A Randomised Controlled Trial.

    PubMed

    Oh, Jaehoon; Lim, Tae Ho; Cho, Youngsuk; Kang, Hyunggoo; Kim, Wonhee; Chee, Youngjoon; Song, Yeongtak; Kim, In Young; Lee, Juncheol

    2016-03-01

    During cardiopulmonary resuscitation (CPR), chest compression (CC) depth is influenced by the surface on which the patient is placed. We hypothesized that training healthcare providers to perform a CC depth of 6-7 cm (instead of 5-6 cm) on a manikin placed on a mattress during CPR in the hospital might improve their proper CC depth. This prospective randomised controlled study involved 66 premedical students without CPR training. The control group was trained to use a CC depth of 5-6 cm (G 5-6), while the experimental group was taught to use a CC depth of 6-7 cm (G 6-7) with a manikin on the floor. All participants performed CCs for 2 min on a manikin that was placed on a bed 1 hour and then again 4 weeks after the training without a feedback. The parameters of CC quality (depth, rate, % of accurate depth) were assessed and compared between the 2 groups. Four students were excluded due to loss to follow-up and recording errors, and data of 62 were analysed. CC depth and % of accurate depth were significantly higher among students in the G 6-7 than G 5-6 both 1 hour and 4 weeks after the training (p<0.001), whereas CC rate was not different between two groups (p>0.05). Training healthcare providers to perform a CC depth of 6-7 cm could improve quality CC depth when performing CCs on patients who are placed on a mattress during CPR in a hospital setting.

  12. Up-Down Hand Position Switch May Delay the Fatigue of Non-Dominant Hand Position Rescuers and Improve Chest Compression Quality during Cardiopulmonary Resuscitation: A Randomized Crossover Manikin Study

    PubMed Central

    Xu, Bing; Wang, Huang-Lei; Xiong, Dan; Sheng, Li-Pin; Yang, Qi-Sheng; Jiang, Shan; Xu, Peng; Chen, Zhi-Qiao; Zhao, Yan

    2015-01-01

    Previous studies have shown improved external chest compression (ECC) quality and delayed rescuer fatigue when the dominant hand (DH) was in contact with the sternum. However, many rescuers prefer placing the non-dominant hand (NH) in contact with the sternum during ECC. We aimed to investigate the effects of up-down hand position switch on the quality of ECC and the fatigue of rescuers during cardiopulmonary resuscitation (CPR). After completion of a review of the standard adult basic life support (BLS) course, every candidate performed 10 cycles of single adult CPR twice on an adult manikin with either a constant hand position (CH) or a switched hand position (SH) in random order at 7-day intervals. The rescuers’ general characteristics, hand positions, physiological signs, fatigue appearance and ECC qualities were recorded. Our results showed no significant differences in chest compression quality for the DH position rescuers between the CH and SH sessions (p>0.05, resp.). And also no significant differences were found for Borg score (p = 0.437) or cycle number (p = 0.127) of fatigue appearance after chest compressions between the two sessions. However, for NH position rescuers, the appearance of fatigue was delayed (p = 0.046), with a lower Borg score in the SH session (12.67 ± 2.03) compared to the CH session (13.33 ± 1.95) (p = 0.011). Moreover, the compression depth was significantly greater in the SH session (39.3 ± 7.2 mm) compared to the CH session (36.3 ± 8.1 mm) (p = 0.015). Our data suggest that the up-down hand position switch during CPR may delay the fatigue of non-dominant hand position rescuers and improve the quality of chest compressions. PMID:26267353

  13. Update on mechanical cardiopulmonary resuscitation devices.

    PubMed

    Rubertsson, Sten

    2016-06-01

    The aim of this review is to update and discuss the use of mechanical chest compression devices in treatment of cardiac arrest. Three recently published large multicenter randomized trials have not been able to show any improved outcome in adult out-of-hospital cardiac arrest patients when compared with manual chest compressions. Mechanical chest compression devices have been developed to better deliver uninterrupted chest compressions of good quality. Prospective large randomized studies have not been able to prove a better outcome compared to manual chest compressions; however, latest guidelines support their use when high-quality manual chest compressions cannot be delivered. Mechanical chest compressions can also be preferred during transportation, in the cath-lab and as a bridge to more invasive support like extracorporeal membrane oxygenation.

  14. The 2015 Resuscitation Council of Asia (RCA) guidelines on adult basic life support for lay rescuers.

    PubMed

    Chung, Sung Phil; Sakamoto, Tetsuya; Lim, Swee Han; Ma, Mathew Huei-Ming; Wang, Tzong-Luen; Lavapie, Francis; Krisanarungson, Sopon; Nonogi, Hiroshi; Hwang, Sung Oh

    2016-08-01

    This paper introduces adult basic life support (BLS) guidelines for lay rescuers of the resuscitation council of Asia (RCA) developed for the first time. The RCA BLS guidelines for lay rescuers have been established by expert consensus among BLS Guidelines Taskforce of the RCA on the basis of the 2015 International Consensus on Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care Science with Treatment Recommendations. The RCA recommends compression-only CPR for lay rescuers and emphasizes high-quality CPR with chest compression depth of approximately 5cm and chest compression rate of 100-120min(-1). Role of emergency medical dispatchers in helping lay rescuers recognize cardiac arrest and perform CPR is also emphasized. The RCA guidelines will contribute to help Asian countries establish and implement their own CPR guidelines in the context of their domestic circumstances. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. A novel educational outreach approach to teach Hands-Only Cardiopulmonary Resuscitation to the public.

    PubMed

    Chang, Mary P; Gent, Lana M; Sweet, Merrilee; Potts, Jerry; Ahtone, Jeral; Idris, Ahamed H

    2017-07-01

    The American Heart Association set goals in 2010 to train 20 million people annually in cardiopulmonary resuscitation and to double bystander response by 2020. These ambitious goals are difficult to achieve without new approaches. The main objective is to evaluate a new approach to cardiopulmonary resuscitation instruction using a self-instructional kiosk to teach Hands-Only CPR to people at a busy international airport. This is a prospective, observational study evaluating a new approach to teach Hands-Only CPR to the public from July 2013 to February 2016. The American Heart Association developed a Hands-Only CPR Kiosk for this project. We assessed the number of participants who viewed the instructional video and practiced chest compressions as well as the quality metrics of the chest compressions. In a 32-month period, there were 23478 visits to the Hands-Only CPR Kiosk and 9006 test sessions; of those practice sessions, 26.2% achieved correct chest compression rate, 60.2% achieved correct chest compression depth, and 63.5% had the correct hand position. There is noticeable public interest in learning Hands-Only CPR by using an airport kiosk and an airport is an opportune place to engage a layperson in learning Hands-Only CPR. The average quality of Hands-Only CPR by the public needs improvement and adding kiosks to other locations in the airport could reach more people and could be replicated in other major airports in the United States. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. [A first step to teaching basic life support in schools: Training the teachers].

    PubMed

    Pichel López, María; Martínez-Isasi, Santiago; Barcala-Furelos, Roberto; Fernández-Méndez, Felipe; Vázquez Santamariña, David; Sánchez-Santos, Luis; Rodríguez-Nuñez, Antonio

    2017-12-07

    Teachers may have an essential role in basic life support (BLS) training in schoolchildren. However, few data are available about their BLS learning abilities. To quantitatively assess the quality of BLS when performed by school teachers after a brief and simple training program. A quasi-experimental study with no control group, and involving primary and secondary education teachers from four privately managed and public funded schools was conducted in 3 stages: 1st. A knowledge test, 2nd: BLS training, and 3rd: Performance test. Training included a 40minutes lecture and 80minutes hands-on session with the help feedback on the quality of the chest compressions. A total of 81 teachers were included, of which 60.5% were women. After training, the percentage of subjects able to perform the BLS sequence rose from 1.2% to 46% (P<.001). Chest compression quality also improved significantly in terms of: correct hands position (97.6 vs. 72.3%; P<.001), mean depth (48.1 vs. 38.8mm; P<.001), percentage that reached recommended depth (46.5 vs. 21.5%; P<.001), percentage of adequate decompression (78.7 vs. 61.2%; P<.05), and percentage of compressions delivered at recommended rate (64.2 vs. 26.9%; P<.001). After and brief and simple training program, teachers of privately managed public funded schools were able to perform the BLS sequence and to produce chest compressions with a quality similar to that obtained by staff with a duty to assist cardiac arrest victims. The ability of schoolteachers to deliver good-quality BLS is a pre-requisite to be engaged in BLS training for schoolchildren. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  17. Even Four Minutes of Poor Quality of CPR Compromises Outcome in a Porcine Model of Prolonged Cardiac Arrest

    PubMed Central

    Li, Heng; Zhang, Lei; Yang, Zhengfei; Huang, Zitong; Chen, Bihua; Li, Yongqin; Yu, Tao

    2013-01-01

    Objective. Untrained bystanders usually delivered suboptimal chest compression to victims who suffered from cardiac arrest in out-of-hospital settings. We therefore investigated the hemodynamics and resuscitation outcome of initial suboptimal quality of chest compressions compared to the optimal ones in a porcine model of cardiac arrest. Methods. Fourteen Yorkshire pigs weighted 30 ± 2 kg were randomized into good and poor cardiopulmonary resuscitation (CPR) groups. Ventricular fibrillation was electrically induced and untreated for 6 mins. In good CPR group, animals received high quality manual chest compressions according to the Guidelines (25% of animal's anterior-posterior thoracic diameter) during first two minutes of CPR compared with poor (70% of the optimal depth) compressions. After that, a 120-J biphasic shock was delivered. If the animal did not acquire return of spontaneous circulation, another 2 mins of CPR and shock followed. Four minutes later, both groups received optimal CPR until total 10 mins of CPR has been finished. Results. All seven animals in good CPR group were resuscitated compared with only two in poor CPR group (P < 0.05). The delayed optimal compressions which followed 4 mins of suboptimal compressions failed to increase the lower coronary perfusion pressure of five non-survival animals in poor CPR group. Conclusions. In a porcine model of prolonged cardiac arrest, even four minutes of initial poor quality of CPR compromises the hemodynamics and survival outcome. PMID:24364028

  18. Effects of depth and chest volume on cardiac function during breath-hold diving.

    PubMed

    Marabotti, Claudio; Scalzini, Alessandro; Cialoni, Danilo; Passera, Mirko; Ripoli, Andrea; L'Abbate, Antonio; Bedini, Remo

    2009-07-01

    Cardiac response to breath-hold diving in human beings is primarily characterized by the reduction of both heart rate and stroke volume. By underwater Doppler-echocardiography we observed a "restrictive/constrictive" left ventricular filling pattern compatible with the idea of chest squeeze and heart compression during diving. We hypothesized that underwater re-expansion of the chest would release heart constriction and normalize cardiac function. To this aim, 10 healthy male subjects (age 34.2 +/- 10.4) were evaluated by Doppler-echocardiography during breath-hold immersion at a depth of 10 m, before and after a single maximal inspiration from a SCUBA device. During the same session, all subjects were also studied at surface (full-body immersion) and at 5-m depth in order to better characterize the relationship of echo-Doppler pattern with depth. In comparison to surface immersion, 5-m deep diving was sufficient to reduce cardiac output (P = 0.042) and increase transmitral E-peak velocity (P < 0.001). These changes remained unaltered at a 10-m depth. Chest expansion at 10 m decreased left ventricular end-systolic volume (P = 0.024) and increased left ventricular stroke volume (P = 0.024). In addition, it decreased transmitral E-peak velocity (P = 0.012) and increased deceleration time of E-peak (P = 0.021). In conclusion the diving response, already evident during shallow diving (5 m) did not progress during deeper dives (10 m). The rapid improvement in systolic and diastolic function observed after lung volume expansion is congruous with the idea of a constrictive effect on the heart exerted by chest squeeze.

  19. Use of a Real-Time Training Software (Laerdal QCPR®) Compared to Instructor-Based Feedback for High-Quality Chest Compressions Acquisition in Secondary School Students: A Randomized Trial.

    PubMed

    Cortegiani, Andrea; Russotto, Vincenzo; Montalto, Francesca; Iozzo, Pasquale; Meschis, Roberta; Pugliesi, Marinella; Mariano, Dario; Benenati, Vincenzo; Raineri, Santi Maurizio; Gregoretti, Cesare; Giarratano, Antonino

    2017-01-01

    High-quality chest compressions are pivotal to improve survival from cardiac arrest. Basic life support training of school students is an international priority. The aim of this trial was to assess the effectiveness of a real-time training software (Laerdal QCPR®) compared to a standard instructor-based feedback for chest compressions acquisition in secondary school students. After an interactive frontal lesson about basic life support and high quality chest compressions, 144 students were randomized to two types of chest compressions training: 1) using Laerdal QCPR® (QCPR group- 72 students) for real-time feedback during chest compressions with the guide of an instructor who considered software data for students' correction 2) based on standard instructor-based feedback (SF group- 72 students). Both groups had a minimum of a 2-minute chest compressions training session. Students were required to reach a minimum technical skill level before the evaluation. We evaluated all students at 7 days from the training with a 2-minute chest compressions session. The primary outcome was the compression score, which is an overall measure of chest compressions quality calculated by the software expressed as percentage. 125 students were present at the evaluation session (60 from QCPR group and 65 from SF group). Students in QCPR group had a significantly higher compression score (median 90%, IQR 81.9-96.0) compared to SF group (median 67%, IQR 27.7-87.5), p = 0.0003. Students in QCPR group performed significantly higher percentage of fully released chest compressions (71% [IQR 24.5-99.0] vs 24% [IQR 2.5-88.2]; p = 0.005) and better chest compression rate (117.5/min [IQR 106-123.5] vs 125/min [115-135.2]; p = 0.001). In secondary school students, a training for chest compressions based on a real-time feedback software (Laerdal QCPR®) guided by an instructor is superior to instructor-based feedback training in terms of chest compression technical skill acquisition. Australian New Zealand Clinical Trials Registry ACTRN12616000383460.

  20. Comparison of relative and actual chest compression depths during cardiac arrest in children, adolescents, and young adults☆

    PubMed Central

    Niles, Dana E.; Nishisaki, Akira; Sutton, Robert M.; Nysæther, Jon; Eilevstjønn, Joar; Leffelman, Jessica; Maltese, Matthew R.; Arbogast, Kristy B.; Abella, Benjamin S.; Helfaer, Mark A.; Berg, Robert A.; Nadkarni, Vinay M.

    2013-01-01

    Aim Cardiopulmonary resuscitation (CPR) guidelines recommend specific chest compression (CC) target depths for children. We quantitatively describe relative anterior–posterior diameter (APD) depth, actual depth, and force of CCs during real CPR events in children. Methods CC depth and force were recorded during real CPR events in children ≥8 years using FDA-approved CC sensor. Patient chest APD was measured at conclusion of each CPR event. CC data was stratified and analyzed according to age (pre-puberty, 8–14 years; post-puberty, 15+ years). Relative (% APD) and actual CC depth, corrected for mattress deflection, were assessed and compared with American Heart Association (AHA) 2005 and 2010 pediatric CPR guidelines. Results 35 events in 32 subjects included 16,158 CCs for data analysis: 16 pre-puberty (CCs = 7484, age 11.9 ± 2 years, APD 164.6 ± 25.1 mm); 19 post-puberty (CCs = 8674, age 18.0 ± 2.7 years, APD 196.5 ± 30.4 mm). After correction for mattress deflection, 92% of CC delivered to pre-puberty were <1/3 relative APD and 60% of CC were <38 mm actual depth. Mean actual CC depth (36.2 ± 9.6 mm vs. 36.8 ± 9.9 mm, p = 0.64), mean relative APD (22.5% ± 7.0% vs. 19.5 ± 6.7%, p = 0.13), and mean CC force (30.7 ± 7.6 kg vs. 33.6 ± 9.4 kg, p = 0.07) were not significantly less in pre-puberty vs. post-puberty. Conclusions During in-hospital cardiac arrest of children ≥8 years, CCs delivered by resuscitation teams were frequently <1/3 relative APD and <38 mm actual depth after mattress deflection correction, below pediatric and adult target guidelines. Mean CC actual depth and force were not significantly different in pre-puberty and post-puberty. Additional investigation to determine depth of CCs to optimize hemodynamics and outcomes is needed to inform future CPR guidelines. PMID:22079410

  1. Training a Chest Compression of 6–7 cm Depth for High Quality Cardiopulmonary Resuscitation in Hospital Setting: A Randomised Controlled Trial

    PubMed Central

    Oh, Jaehoon; Cho, Youngsuk; Kang, Hyunggoo; Kim, Wonhee; Chee, Youngjoon; Song, Yeongtak; Kim, In Young; Lee, Juncheol

    2016-01-01

    Purpose During cardiopulmonary resuscitation (CPR), chest compression (CC) depth is influenced by the surface on which the patient is placed. We hypothesized that training healthcare providers to perform a CC depth of 6–7 cm (instead of 5–6 cm) on a manikin placed on a mattress during CPR in the hospital might improve their proper CC depth. Materials and Methods This prospective randomised controlled study involved 66 premedical students without CPR training. The control group was trained to use a CC depth of 5–6 cm (G 5–6), while the experimental group was taught to use a CC depth of 6–7 cm (G 6–7) with a manikin on the floor. All participants performed CCs for 2 min on a manikin that was placed on a bed 1 hour and then again 4 weeks after the training without a feedback. The parameters of CC quality (depth, rate, % of accurate depth) were assessed and compared between the 2 groups. Results Four students were excluded due to loss to follow-up and recording errors, and data of 62 were analysed. CC depth and % of accurate depth were significantly higher among students in the G 6–7 than G 5–6 both 1 hour and 4 weeks after the training (p<0.001), whereas CC rate was not different between two groups (p>0.05). Conclusion Training healthcare providers to perform a CC depth of 6–7 cm could improve quality CC depth when performing CCs on patients who are placed on a mattress during CPR in a hospital setting. PMID:26847307

  2. Utility of a simple lighting device to improve chest compressions learning.

    PubMed

    González-Calvete, L; Barcala-Furelos, R; Moure-González, J D; Abelairas-Gómez, C; Rodríguez-Núñez, A

    2017-11-01

    The recommendations on cardiopulmonary resuscitation (CPR) emphasize the quality of the manoeuvres, especially chest compressions (CC). Audiovisual feedback devices could improve the quality of the CC during CPR. The aim of this study was to evaluate the usefulness of a simple lighting device as a visual aid during CPR on a mannequin. Twenty-two paediatricians who attended an accredited paediatric CPR course performed, in random order, 2min of CPR on a mannequin without and with the help of a simple lighting device, which flashes at a frequency of 100 cycles per minute. The following CC variables were analyzed using a validated compression quality meter (CPRmeter ® ): depth, decompression, rate, CPR time and percentage of compressions. With the lighting device, participants increased average quality (60.23±54.50 vs. 79.24±9.80%; P=.005), percentage in target depth (48.86±42.67 vs. 72.95±20.25%; P=.036) and rate (35.82±37.54 vs. 67.09±31.95%; P=.024). A simple light device that flashes at the recommended frequency improves the quality of CC performed by paediatric residents on a mannequin. The usefulness of this CPR aid system should be assessed in real patients. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. A randomized comparison of three chest compression techniques and associated hemodynamic effect during infant CPR: A randomized manikin study.

    PubMed

    Smereka, Jacek; Szarpak, Lukasz; Rodríguez-Núñez, Antonio; Ladny, Jerzy R; Leung, Steve; Ruetzler, Kurt

    2017-10-01

    Pediatric cardiac arrest is an uncommon but critical life-threatening event requiring effective cardiopulmonary resuscitation. High-quality cardio-pulmonary resuscitation (CPR) is essential, but is poorly performed, even by highly skilled healthcare providers. The recently described two-thumb chest compression technique (nTTT) consists of the two thumbs directed at the angle of 90° to the chest while having the fingers fist-clenched. This technique might facilitate adequate chest-compression depth, chest-compression rate and rate of full chest-pressure relief. 42 paramedics from the national Emergency Medical Service of Poland performed three single-rescuer CPR sessions for 10 minutes each. Each session was randomly assigned to the conventional two-thumb (TTHT), the conventional two-finger (TFT) or the nTTT. The manikin used for this study was connected with an arterial blood pressure measurement device and blood measurements were documented on a 10-seconds cycle. The nTTT provided significant higher systolic (82 vs. 30 vs. 41 mmHg). A statistically significant difference was noticed between nTTT and TFT (p<.001), nTTT and TTHT (p<0.001), TFT and TTHT (p=0.003). The median diastolic preassure using nTTT was 16 mmHg compared with 9 mmHg for TFT (p<0.001), and 9.5 mmHg for TTHT (p<0.001). Mean arterial pressure using distinct methods varied and amounted to 40 vs. 22. vs. 26 mmHg (nTTT vs. TFT vs. TTHT, respectively). A statistically significant difference was noticed between nTTT and TFT (p<0.001), nTTT and TTEHT (p<0.001), and TFT and TTHT (p<0.001). The highest median pulse pressure was obtained by the nTTT 67.5 mmHg. Pulse pressure was 31.5 mmHg in the TTHT and 24 mmHg in the TFT. The difference between TFT and TTHT (p=0.025), TFT and nTTT (p<0.001), as well as between TTHT and nTTT (p<0.001) were statistically significant. The new nTTT technique generated higher arterial blood pressures compared to established chest compression techniques using an infant manikin model, suggesting a more effective chest compression. Our results have important clinical implications as nTTT was simple to perform and could be widely taught to both healthcare professionals and bystanders. Whether this technique translates to improved outcomes over existing techniques needs further animal studies and subsequent human trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Cardiopulmonary resuscitation duty cycle in out-of-hospital cardiac arrest.

    PubMed

    Johnson, Bryce V; Johnson, Bryce; Coult, Jason; Fahrenbruch, Carol; Blackwood, Jennifer; Sherman, Larry; Kudenchuk, Peter; Sayre, Michael; Rea, Thomas

    2015-02-01

    Duty cycle is the portion of time spent in compression relative to total time of the compression-decompression cycle. Guidelines recommend a 50% duty cycle based largely on animal investigation. We undertook a descriptive evaluation of duty cycle in human resuscitation, and whether duty cycle correlates with other CPR measures. We calculated the duty cycle, compression depth, and compression rate during EMS resuscitation of 164 patients with out-of-hospital ventricular fibrillation cardiac arrest. We captured force recordings from a chest accelerometer to measure ten-second CPR epochs that preceded rhythm analysis. Duty cycle was calculated using two methods. Effective compression time (ECT) is the time from beginning to end of compression divided by total period for that compression-decompression cycle. Area duty cycle (ADC) is the ratio of area under the force curve divided by total area of one compression-decompression cycle. We evaluated the compression depth and compression rate according to duty cycle quartiles. There were 369 ten-second epochs among 164 patients. The median duty cycle was 38.8% (SD=5.5%) using ECT and 32.2% (SD=4.3%) using ADC. A relatively shorter compression phase (lower duty cycle) was associated with greater compression depth (test for trend <0.05 for ECT and ADC) and slower compression rate (test for trend <0.05 for ADC). Sixty-one of 164 patients (37%) survived to hospital discharge. Duty cycle was below the 50% recommended guideline, and was associated with compression depth and rate. These findings provider rationale to incorporate duty cycle into research aimed at understanding optimal CPR metrics. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Improved recognition of ineffective chest compressions after a brief Crew Resource Management (CRM) training: a prospective, randomised simulation study.

    PubMed

    Haffner, Leopold; Mahling, Moritz; Muench, Alexander; Castan, Christoph; Schubert, Paul; Naumann, Aline; Reddersen, Silke; Herrmann-Werner, Anne; Reutershan, Jörg; Riessen, Reimer; Celebi, Nora

    2017-03-03

    Chest compressions are a core element of cardio-pulmonary resuscitation. Despite periodic training, real-life chest compressions have been reported to be overly shallow and/or fast, very likely affecting patient outcomes. We investigated the effect of a brief Crew Resource Management (CRM) training program on the correction rate of improperly executed chest compressions in a simulated cardiac arrest scenario. Final-year medical students (n = 57) were randomised to receive a 10-min computer-based CRM or a control training on ethics. Acting as team leaders, subjects performed resuscitation in a simulated cardiac arrest scenario before and after the training. Team members performed standardised overly shallow and fast chest compressions. We analysed how often the team leader recognised and corrected improper chest compressions, as well as communication and resuscitation quality. After the CRM training, team leaders corrected improper chest compressions (35.5%) significantly more often compared with those undergoing control training (7.7%, p = 0.03*). Consequently, four students have to be trained (number needed to treat = 3.6) for one improved chest compression scenario. Communication quality assessed by the Leader Behavior Description Questionnaire significantly increased in the intervention group by a mean of 4.5 compared with 2.0 (p = 0.01*) in the control group. A computer-based, 10-min CRM training improved the recognition of ineffective of chest compressions. Furthermore, communication quality increased. As guideline-adherent chest compressions have been linked to improved patient outcomes, our CRM training might represent a brief and affordable approach to increase chest compression quality and potentially improve patient outcomes.

  6. 2017 American Heart Association Focused Update on Pediatric Basic Life Support and Cardiopulmonary Resuscitation Quality: An Update to the American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

    PubMed

    Atkins, Dianne L; de Caen, Allan R; Berger, Stuart; Samson, Ricardo A; Schexnayder, Stephen M; Joyner, Benny L; Bigham, Blair L; Niles, Dana E; Duff, Jonathan P; Hunt, Elizabeth A; Meaney, Peter A

    2018-01-02

    This focused update to the American Heart Association guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care follows the Pediatric Task Force of the International Liaison Committee on Resuscitation evidence review. It aligns with the International Liaison Committee on Resuscitation's continuous evidence review process, and updates are published when the International Liaison Committee on Resuscitation completes a literature review based on new science. This update provides the evidence review and treatment recommendation for chest compression-only CPR versus CPR using chest compressions with rescue breaths for children <18 years of age. Four large database studies were available for review, including 2 published after the "2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care." Two demonstrated worse 30-day outcomes with chest compression-only CPR for children 1 through 18 years of age, whereas 2 studies documented no difference between chest compression-only CPR and CPR using chest compressions with rescue breaths. When the results were analyzed for infants <1 year of age, CPR using chest compressions with rescue breaths was better than no CPR but was no different from chest compression-only CPR in 1 study, whereas another study observed no differences among chest compression-only CPR, CPR using chest compressions with rescue breaths, and no CPR. CPR using chest compressions with rescue breaths should be provided for infants and children in cardiac arrest. If bystanders are unwilling or unable to deliver rescue breaths, we recommend that rescuers provide chest compressions for infants and children. © 2017 American Heart Association, Inc.

  7. Coronary perfusion pressure and compression quality in maternal cardiopulmonary resuscitation in supine and left-lateral tilt positions: A prospective, crossover study using mannequins and swine models.

    PubMed

    Dohi, Satoshi; Ichizuka, Kiyotake; Matsuoka, Ryu; Seo, Kohei; Nagatsuka, Masaaki; Sekizawa, Akihiko

    2017-09-01

    The risk of maternal and fetal mortality is high if cardiopulmonary arrest occurs during pregnancy. To assess the best position for maternal cardiopulmonary resuscitation (CPR), a prospective randomized crossover study was undertaken, involving basic life support mannequin-based simulation (BLS-MS) and a swine model of pulseless electrical activity (an unstable cardiac state) incorporating a fetal mannequin (PEA-FM). The BLS-MS (performed by certified rescuers) served to evaluate the quality of chest compressions in 30° left lateral tilt (LLT) and supine positions. Based on a 5-point scale, each rescuer subjectively graded their experience. The PEA-FM model was used to compare coronary perfusion pressure readings during CPR in supine, supine with left uterine displacement, 30° LLT, and 30° right lateral tilt positions. Compression rate and correctness of hand position, compression depth, and recoil were measures of compression quality (BLS-MS). Compared with LLT position, supine position enabled correct hand position (rate: 0.99 vs 0.88; p<0.05) and compression depth (rate: 0.76 vs 0.36; p<0.001) significantly more often. Moreover, BLS-MS rescuers found chest compressions significantly easier to perform with the mannequin in supine (vs LLT) position (difficulty score: 1.75 vs 3.95; p<0.001). In the PEA-FM study arm, supine position with left uterine displacement and right lateral tilt positions had the highest and lowest recorded coronary perfusion pressure readings, respectively. Supine position with left uterine displacement is optimal for maternal CPR. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  8. Quality of dispatch-assisted cardiopulmonary resuscitation by lay rescuers following a standard protocol in Japan: an observational simulation study.

    PubMed

    Asai, Hideki; Fukushima, Hidetada; Bolstad, Francesco; Okuchi, Kazuo

    2018-04-01

    Bystander cardiopulmonary resuscitation (CPR) is essential for improving the outcomes of sudden cardiac arrest patients. It has been reported that dispatch-assisted CPR (DACPR) accounts for more than half of the incidence of CPR undertaken by bystanders. Its quality, however, can be suboptimal. We aimed to measure the quality of DACPR using a simulation study. We recruited laypersons at a shopping mall and measured the quality of CPR carried out in our simulation. Dispatchers provided instruction in accordance with the standard DACPR protocol in Japan. Twenty-three laypersons (13 with CPR training experience within the past 2 years and 10 with no training experience) participated in this study. The median chest compression rate and depth were 106/min and 33 mm, respectively. The median time interval from placing the 119 call to the start of chest compressions was 119 s. No significant difference was found between the groups with and without training experience. However, subjects with training experience more frequently placed their hands correctly on the manikin (84.6% versus 40.0%; P = 0.026). Twelve participants (52.2%, seven in trained and five in untrained group) interrupted chest compressions for 3-18 s, because dispatchers asked if the patient started breathing or moving. This current simulation study showed that the quality of DACPR carried out by lay rescuers can be less than optimal in terms of depth, hand placement, and minimization of pauses. Further studies are required to explore better DACPR instruction methods to help lay rescuers perform CPR with optimal quality.

  9. Evaluation of chest compression effect on airway management with air-Q, aura-i, i-gel, and Fastrack intubating supraglottic devices by novice physicians: a randomized crossover simulation study.

    PubMed

    Komasawa, Nobuyasu; Ueki, Ryusuke; Kaminoh, Yoshiroh; Nishi, Shin-Ichi

    2014-10-01

    In the 2010 American Heart Association guidelines, supraglottic devices (SGDs) such as the laryngeal mask are proposed as alternatives to tracheal intubation for cardiopulmonary resuscitation. Some SGDs can also serve as a means for tracheal intubation after successful ventilation. The purpose of this study was to evaluate the effect of chest compression on airway management with four intubating SGDs, aura-i (aura-i), air-Q (air-Q), i-gel (i-gel), and Fastrack (Fastrack), during cardiopulmonary resuscitation using a manikin. Twenty novice physicians inserted the four intubating SGDs into a manikin with or without chest compression. Insertion time and successful ventilation rate were measured. For cases of successful ventilation, blind tracheal intubation via the intubating SGD was performed with chest compression and success or failure within 30 s was recorded. Chest compression did not decrease the ventilation success rate of the four intubating SGDs (without chest compression (success/total): air-Q, 19/20; aura-i, 19/20; i-gel, 18/20; Fastrack, 19/20; with chest compression: air-Q, 19/20; aura-i, 19/20; i-gel, 16/20; Fastrack, 18/20). Insertion time was significantly lengthened by chest compression in the i-gel trial (P < 0.05), but not with the other three devices. The blind intubation success rate with chest compression was the highest in the air-Q trial (air-Q, 15/19; aura-i, 14/19; i-gel, 12/16; Fastrack, 10/18). This simulation study revealed the utility of intubating SGDs for airway management during chest compression.

  10. A comparison of video review and feedback device measurement of chest compressions quality during pediatric cardiopulmonary resuscitation.

    PubMed

    Hsieh, Ting-Chang; Wolfe, Heather; Sutton, Robert; Myers, Sage; Nadkarni, Vinay; Donoghue, Aaron

    2015-08-01

    To describe chest compression (CC) rate, depth, and leaning during pediatric cardiopulmonary resuscitation (CPR) as measured by two simultaneous methods, and to assess the accuracy and reliability of video review in measuring CC quality. Resuscitations in a pediatric emergency department are videorecorded for quality improvement. Patients aged 8-18 years receiving CPR under videorecording were eligible for inclusion. CPR was recorded by a pressure/accelerometer feedback device and tabulated in 30-s epochs of uninterrupted CC. Investigators reviewed videorecorded CPR and measured rate, depth, and release by observation. Raters categorized epochs as 'meeting criteria' if 80% of CCs in an epoch were done with appropriate depth (>45 mm) and/or release (<2.5 kg leaning). Comparison between device measurement and video was made by Spearman's ρ for rate and by κ statistic for depth and release. Interrater reliability for depth and release was measured by κ statistic. Five patients underwent videorecorded CPR using the feedback device. 97 30-s epochs of CCs were analyzed. CCs met criteria for rate in 74/97 (76%) of epochs; depth in 38/97 (39%); release in 82/97 (84%). Agreement between video and feedback device for rate was good (ρ = 0.77); agreement was poor for depth and release (κ 0.04-0.41). Interrater reliability for depth and release measured by video was poor (κ 0.04-0.49). Video review measured CC rate accurately; depth and release were not reliably or accurately assessed by video. Future research should focus on the optimal combination of methods for measuring CPR quality. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. How effectively can young people perform dispatcher-instructed cardiopulmonary resuscitation without training?

    PubMed

    Beard, Matthew; Swain, Andrew; Dunning, Andrew; Baine, Julie; Burrowes, Corey

    2015-05-01

    Survival from out-of-hospital cardiac arrest is increased by bystander cardiopulmonary resuscitation (CPR). Bystander performance can be improved when CPR instructions are delivered by a calltaker at the Emergency Communications Centre. Little is known about a young person's ability to understand these instructions and perform CPR correctly. We assessed the ability of a group of untrained young people to effectively apply these directions to an adult resuscitation manikin. 87 youngsters aged 7-15 years with no previous training in CPR were separately equipped with a mobile phone and an adult assessment manikin. They phoned the emergency number (111) and were automatically diverted to a senior emergency medical dispatcher (EMD). The EMD delivered resuscitation instructions which complied fully with Medical Priority Dispatch System (version 12.1). Performance was monitored using a Laerdal Computerised Skill Reporting System. Average compression depth increased with age from 10.3 mm to 30 mm for 8 and 15 year olds respectively. 100 compressions per minute was achieved in youngsters aged 10 years and older but the rate fatigued over time and improved after interruption for two ventilations. Those aged 11 years and older consistently compressed the chest from 31 mm to 50mm. Only one participant could successfully ventilate the manikin by mouth-to-mouth. This study demonstrates that untrained youngsters should perform compression-only CPR. From 11 years of age, they can effectively perform dispatcher-directed CPR by compressing the chest at an appropriate rate and depth. However, their technique benefits from formal training. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. The association between AHA CPR quality guideline compliance and clinical outcomes from out-of-hospital cardiac arrest.

    PubMed

    Cheskes, Sheldon; Schmicker, Robert H; Rea, Tom; Morrison, Laurie J; Grunau, Brian; Drennan, Ian R; Leroux, Brian; Vaillancourt, Christian; Schmidt, Terri A; Koller, Allison C; Kudenchuk, Peter; Aufderheide, Tom P; Herren, Heather; Flickinger, Katharyn H; Charleston, Mark; Straight, Ron; Christenson, Jim

    2017-07-01

    Measures of chest compression fraction (CCF), compression rate, compression depth and pre-shock pause have all been independently associated with improved outcomes from out-of-hospital (OHCA) cardiac arrest. However, it is unknown whether compliance with American Heart Association (AHA) guidelines incorporating all the aforementioned metrics, is associated with improved survival from OHCA. We performed a secondary analysis of prospectively collected data from the Resuscitation Outcomes Consortium Epistry-Cardiac Arrest database. As per the 2015 American Heart Association (AHA) guidelines, guideline compliant cardiopulmonary resuscitation (CPR) was defined as CCF >0.8, chest compression rate 100-120/minute, chest compression depth 50-60mm, and pre-shock pause <10s. Multivariable logistic regression models controlling for Utstein variables were used to assess the relationship between global guideline compliance and survival to hospital discharge and neurologically intact survival with MRS ≤3. Due to potential confounding between CPR quality metrics and cases that achieved early ROSC, we performed an a priori subgroup analysis restricted to patients who obtained ROSC after ≥10min of EMS resuscitation. After allowing for study exclusions, 19,568 defibrillator records were collected over a 4-year period ending in June 2015. For all reported models, the reference standard included all cases who did not meet all CPR quality benchmarks. For the primary model (CCF, rate, depth), there was no significant difference in survival for resuscitations that met all CPR quality benchmarks (guideline compliant) compared to the reference standard (OR 1.26; 95% CI: 0.80, 1.97). When the dataset was restricted to patients obtaining ROSC after ≥10min of EMS resuscitation (n=4,158), survival was significantly higher for those resuscitations that were guideline compliant (OR 2.17; 95% CI: 1.11, 4.27) compared to the reference standard. Similar findings were obtained for neurologically intact survival with MRS ≤3 (OR 3.03; 95% CI: 1.12, 8.20). In this observational study, compliance with AHA guidelines for CPR quality was not associated with improved outcomes from OHCA. Conversely, when restricting the cohort to those with late ROSC, compliance with guidelines was associated with improved clinical outcomes. Strategies to improve overall guideline compliance may have a significant impact on outcomes from OHCA. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. What is the optimal chest compression depth during out-of-hospital cardiac arrest resuscitation of adult patients?

    PubMed

    Stiell, Ian G; Brown, Siobhan P; Nichol, Graham; Cheskes, Sheldon; Vaillancourt, Christian; Callaway, Clifton W; Morrison, Laurie J; Christenson, James; Aufderheide, Tom P; Davis, Daniel P; Free, Cliff; Hostler, Dave; Stouffer, John A; Idris, Ahamed H

    2014-11-25

    The 2010 American Heart Association guidelines suggested an increase in cardiopulmonary resuscitation compression depth with a target >50 mm and no upper limit. This target is based on limited evidence, and we sought to determine the optimal compression depth range. We studied emergency medical services-treated out-of-hospital cardiac arrest patients from the Resuscitation Outcomes Consortium Prehospital Resuscitation Impedance Valve and Early Versus Delayed Analysis clinical trial and the Epistry-Cardiac Arrest database. We calculated adjusted odds ratios for survival to hospital discharge, 1-day survival, and any return of circulation. We included 9136 adult patients from 9 US and Canadian cities with a mean age of 67.5 years, mean compression depth of 41.9 mm, and a return of circulation of 31.3%, 1-day survival of 22.8%, and survival to hospital discharge of 7.3%. For survival to discharge, the adjusted odds ratios were 1.04 (95% CI, 1.00-1.08) for each 5-mm increment in compression depth, 1.45 (95% CI, 1.20-1.76) for cases within 2005 depth range (>38 mm), and 1.05 (95% CI, 1.03-1.08) for percentage of minutes in depth range (10% change). Covariate-adjusted spline curves revealed that the maximum survival is at a depth of 45.6 mm (15-mm interval with highest survival between 40.3 and 55.3 mm) with no differences between men and women. This large study of out-of-hospital cardiac arrest patients demonstrated that increased cardiopulmonary resuscitation compression depth is strongly associated with better survival. Our adjusted analyses, however, found that maximum survival was in the depth interval of 40.3 to 55.3 mm (peak, 45.6 mm), suggesting that the 2010 American Heart Association cardiopulmonary resuscitation guideline target may be too high. http://www.clinicaltrials.gov. Unique identifier: NCT00394706. © 2014 American Heart Association, Inc.

  14. Kids save lives: a six-year longitudinal study of schoolchildren learning cardiopulmonary resuscitation: Who should do the teaching and will the effects last?

    PubMed

    Lukas, Roman-Patrik; Van Aken, Hugo; Mölhoff, Thomas; Weber, Thomas; Rammert, Monika; Wild, Elke; Bohn, Andreas

    2016-04-01

    This prospective longitudinal study over 6 years compared schoolteachers and emergency physicians as resuscitation trainers for schoolchildren. It also investigated whether pupils who were trained annually for 3 years retain their resuscitation skills after the end of this study. A total of 261 pupils (fifth grade) at two German grammar schools received resuscitation training by trained teachers or by emergency physicians. The annual training events stopped after 3 years in one group and continued for 6 years in a second group. We measured knowledge about resuscitation (questionnaire), chest compression rate (min(-1)), chest compression depth (mm), ventilation rate (min(-1)), ventilation volume (mL), self-efficacy (questionnaire). Their performance was evaluated after 1, 3 and 6 years. The training events increased the pupils' knowledge and practical skills. When trained by teachers, the pupils achieved better results for knowledge (92.86% ± 8.38 vs. 90.10% ± 8.63, P=0.04) and ventilation rate (4.84/min ± 4.05 vs. 3.76/min ± 2.37, P=0.04) than when they were trained by emergency physicians. There were no differences with regard to chest compression rate, depth, ventilation volume, or self-efficacy at the end of the study. Knowledge and skills after 6 years were equivalent in the group with 6 years training compared with 3 years training. Trained teachers can provide adequate resuscitation training in schools. Health-care professionals are not mandatory for CPR training (easier for schools to implement resuscitation training). The final evaluation after 6 years showed that resuscitation skills are retained even when training is interrupted for 3 years. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  15. The evaluation of upper body muscle activity during the performance of external chest compressions in simulated hypogravity

    NASA Astrophysics Data System (ADS)

    Krygiel, Rebecca G.; Waye, Abigail B.; Baptista, Rafael Reimann; Heidner, Gustavo Sandri; Rehnberg, Lucas; Russomano, Thais

    2014-04-01

    BACKGROUND: This original study evaluated the electromyograph (EMG) activity of four upper body muscles: triceps brachii, erector spinae, upper rectus abdominis, and pectoralis major, while external chest compressions (ECCs) were performed in simulated Martian hypogravity using a Body Suspension Device, counterweight system, and standard full body cardiopulmonary resuscitation (CPR) mannequin. METHOD: 20 young, healthy male subjects were recruited. One hundred compressions divided into four sets, with roughly six seconds between each set to indicate 'ventilation', were performed within approximately a 1.5 minute protocol. Chest compression rate, depth and number were measured along with the subject's heart rate (HR) and rating of perceived exertion (RPE). RESULTS: All mean values were used in two-tailed t-tests using SPSS to compare +1 Gz values (control) versus simulated hypogravity values. The AHA (2005) compression standards were maintained in hypogravity. RPE and HR increased by 32% (p < 0.001) and 44% (p = 0.002), respectively, when ECCs were performed during Mars simulation, in comparison to +1 Gz. In hypogravity, the triceps brachii showed significantly less activity (p < 0.001) when compared with the other three muscles studied. The comparison of all the other muscles showed no difference at +1 Gz or in hypogravity. CONCLUSIONS: This study was among the first of its kind, however several limitations were faced which hopefully will not exist in future studies. Evaluation of a great number of muscles will allow space crews to focus on specific strengthening exercises within their current training regimes in case of a serious cardiac event in hypogravity.

  16. Motion detection technology as a tool for cardiopulmonary resuscitation (CPR) quality training: a randomised crossover mannequin pilot study.

    PubMed

    Semeraro, Federico; Frisoli, Antonio; Loconsole, Claudio; Bannò, Filippo; Tammaro, Gaetano; Imbriaco, Guglielmo; Marchetti, Luca; Cerchiari, Erga L

    2013-04-01

    Outcome after cardiac arrest is dependent on the quality of chest compressions (CC). A great number of devices have been developed to provide guidance during CPR. The present study evaluates a new CPR feedback system (Mini-VREM: Mini-Virtual Reality Enhanced Mannequin) designed to improve CC during training. Mini-VREM system consists of a Kinect(®) (Microsoft, Redmond, WA, USA) motion sensing device and specifically developed software to provide audio-visual feedback. Mini-VREM was connected to a commercially available mannequin (Laerdal Medical, Stavanger, Norway). Eighty trainees (healthcare professionals and lay people) volunteered in this randomised crossover pilot study. All subjects performed a 2 min CC trial, 1h pause and a second 2 min CC trial. The first group (FB/NFB, n=40) performed CC with Mini-VREM feedback (FB) followed by CC without feedback (NFB). The second group (NFB/FB, n=40) performed vice versa. Primary endpoints: adequate compression (compression rate between 100 and 120 min(-1) and compression depth between 50 and 60mm); compressions rate within 100-120 min(-1); compressions depth within 50-60mm. When compared to the performance without feedback, with Mini-VREM feedback compressions were more adequate (FB 35.78% vs. NFB 7.27%, p<0.001) and more compressions achieved target rate (FB 72.04% vs. 31.42%, p<0.001) and target depth (FB 47.34% vs. 24.87%, p=0.002). The participants perceived the system to be easy to use with effective feedback. The Mini-VREM system was able to improve significantly the CC performance by healthcare professionals and by lay people in a simulated CA scenario, in terms of compression rate and depth. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Mechanical versus manual chest compressions for cardiac arrest.

    PubMed

    Brooks, Steven C; Hassan, Nizar; Bigham, Blair L; Morrison, Laurie J

    2014-02-27

    This is the first update of the Cochrane review on mechanical chest compression devices published in 2011 (Brooks 2011). Mechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR). To assess the effectiveness of mechanical chest compressions versus standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest. We searched the Cochrane Central Register of Controlled Studies (CENTRAL; 2013, Issue 12), MEDLINE Ovid (1946 to 2013 January Week 1), EMBASE (1980 to 2013 January Week 2), Science Citation abstracts (1960 to 18 November 2009), Science Citation Index-Expanded (SCI-EXPANDED) (1970 to 11 January 2013) on Thomson Reuters Web of Science, biotechnology and bioengineering abstracts (1982 to 18 November 2009), conference proceedings Citation Index-Science (CPCI-S) (1990 to 11 January 2013) and clinicaltrials.gov (2 August 2013). We applied no language restrictions. Experts in the field of mechanical chest compression devices and manufacturers were contacted. We included randomised controlled trials (RCTs), cluster RCTs and quasi-randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with atraumatic cardiac arrest. Two review authors abstracted data independently; disagreement between review authors was resolved by consensus and by a third review author if consensus could not be reached. The methodologies of selected studies were evaluated by a single author for risk of bias. The primary outcome was survival to hospital discharge with good neurological outcome. We planned to use RevMan 5 (Version 5.2. The Nordic Cochrane Centre) and the DerSimonian & Laird method (random-effects model) to provide a pooled estimate for risk ratio (RR) with 95% confidence intervals (95% CIs), if data allowed. Two new studies were included in this update. Six trials in total, including data from 1166 participants, were included in the review. The overall quality of included studies was poor, and significant clinical heterogeneity was observed. Only one study (N = 767) reported survival to hospital discharge with good neurological function (defined as a Cerebral Performance Category score of one or two), demonstrating reduced survival with mechanical chest compressions when compared with manual chest compressions (RR 0.41, 95% CI 0.21 to 0.79). Data from four studies demonstrated increased return of spontaneous circulation, and data from two studies demonstrated increased survival to hospital admission with mechanical chest compressions as compared with manual chest compressions, but none of the individual estimates reached statistical significance. Marked clinical heterogeneity between studies precluded any pooled estimates of effect. Evidence from RCTs in humans is insufficient to conclude that mechanical chest compressions during cardiopulmonary resuscitation for cardiac arrest are associated with benefit or harm. Widespread use of mechanical devices for chest compressions during cardiac events is not supported by this review. More RCTs that measure and account for the CPR process in both arms are needed to clarify the potential benefit to be derived from this intervention.

  18. Continuous chest compression cardiopulmonary resuscitation training promotes rescuer self-confidence and increased secondary training: a hospital-based randomized controlled trial*.

    PubMed

    Blewer, Audrey L; Leary, Marion; Esposito, Emily C; Gonzalez, Mariana; Riegel, Barbara; Bobrow, Bentley J; Abella, Benjamin S

    2012-03-01

    Recent work suggests that delivery of continuous chest compression cardiopulmonary resuscitation is an acceptable layperson resuscitation strategy, although little is known about layperson preferences for training in continuous chest compression cardiopulmonary resuscitation. We hypothesized that continuous chest compression cardiopulmonary resuscitation education would lead to greater trainee confidence and would encourage wider dissemination of cardiopulmonary resuscitation skills compared to standard cardiopulmonary resuscitation training (30 compressions: two breaths). Prospective, multicenter randomized study. Three academic medical center inpatient wards. Adult family members or friends (≥ 18 yrs old) of inpatients admitted with cardiac-related diagnoses. In a multicenter randomized trial, family members of hospitalized patients were trained via the educational method of video self-instruction. Subjects were randomized to continuous chest compression cardiopulmonary resuscitation or standard cardiopulmonary resuscitation educational modes. Cardiopulmonary resuscitation performance data were collected using a cardiopulmonary resuscitation skill-reporting manikin. Trainee perspectives and secondary training rates were assessed through mixed qualitative and quantitative survey instruments. Chest compression performance was similar in both groups. The trainees in the continuous chest compression cardiopulmonary resuscitation group were significantly more likely to express a desire to share their training kit with others (152 of 207 [73%] vs. 133 of 199 [67%], p = .03). Subjects were contacted 1 month after initial enrollment to assess actual sharing, or "secondary training." Kits were shared with 2.0 ± 3.4 additional family members in the continuous chest compression cardiopulmonary resuscitation group vs. 1.2 ± 2.2 in the standard cardiopulmonary resuscitation group (p = .03). As a secondary result, trainees in the continuous chest compression cardiopulmonary resuscitation group were more likely to rate themselves "very comfortable" with the idea of using cardiopulmonary resuscitation skills in actual events than the standard cardiopulmonary resuscitation trainees (71 of 207 [34%] vs. 57 of 199 [28%], p = .08). Continuous chest compression cardiopulmonary resuscitation education resulted in a statistically significant increase in secondary training. This work suggests that implementation of video self-instruction training programs using continuous chest compression cardiopulmonary resuscitation may confer broader dissemination of life-saving skills and may promote rescuer comfort with newly acquired cardiopulmonary resuscitation knowledge. URL: http://clinicaltrials.gov. Unique identifier: NCT01260441.

  19. Continuous chest compression cardiopulmonary resuscitation training promotes rescuer self-confidence and increased secondary training: A hospital-based randomized controlled trial

    PubMed Central

    Blewer, Audrey L.; Leary, Marion; Esposito, Emily C.; Gonzalez, Mariana; Riegel, Barbara; Bobrow, Bentley J.; Abella, Benjamin S.

    2013-01-01

    Objective Recent work suggests that delivery of continuous chest compression cardiopulmonary resuscitation is an acceptable layperson resuscitation strategy, although little is known about layperson preferences for cardiopulmonary resuscitation training in continuous chest compression cardiopulmonary resuscitation. We hypothesized that continuous chest compression cardiopulmonary resuscitation education would lead to greater trainee confidence and would encourage wider dissemination of cardiopulmonary resuscitation skills compared to standard cardiopulmonary resuscitation training (30 compressions: two breaths). Design Prospective, multicenter cohort study. Setting Three academic medical center inpatient wards. Subjects Adult family members or friends (≥18 yrs old) of inpatients admitted with cardiac-related diagnoses. Interventions In a multicenter randomized trial, family members of hospitalized patients were trained via the educational method of video self-instruction. Subjects were randomized to continuous chest compression cardiopulmonary resuscitation or standard cardiopulmonary resuscitation educational modes. Measurements Cardiopulmonary resuscitation performance data were collected using a cardiopulmonary resuscitation skill-reporting manikin. Trainee perspectives and secondary training rates were assessed through mixed qualitative and quantitative survey instruments. Main Results Chest compression performance was similar in both groups. The trainees in the continuous chest compression cardiopulmonary resuscitation group were significantly more likely to express a desire to share their training kit with others (152 of 207 [73%] vs. 133 of 199 [67%], p = .03). Subjects were contacted 1 month after initial enrollment to assess actual sharing, or “secondary training.” Kits were shared with 2.0 ± 3.4 additional family members in the continuous chest compression cardiopulmonary resuscitation group vs. 1.2 ± 2.2 in the standard cardiopulmonary resuscitation group (p = .03). As a secondary result, trainees in the continuous chest compression cardiopulmonary resuscitation group were more likely to rate themselves “very comfortable” with the idea of using cardiopulmonary resuscitation skills in actual events than the standard cardiopulmonary resuscitation trainees (71 of 207 [34%] vs. 57 of 199 [28%], p = .08). Conclusions Continuous chest compression cardiopulmonary resuscitation education resulted in a statistically significant increase in secondary training. This work suggests that implementation of video self-instruction training programs using continuous chest compression cardiopulmonary resuscitation may confer broader dissemination of life-saving skills and may promote rescuer comfort with newly acquired cardiopulmonary resuscitation knowledge. Clinical Trial Registration URL: http://clinicaltrials.gov. Unique identifier: NCT01260441. PMID:22080629

  20. Long-term retention of cardiopulmonary resuscitation skills after shortened chest compression-only training and conventional training: a randomized controlled trial.

    PubMed

    Nishiyama, Chika; Iwami, Taku; Kitamura, Tetsuhisa; Ando, Masahiko; Sakamoto, Tetsuya; Marukawa, Seishiro; Kawamura, Takashi

    2014-01-01

    It is unclear how much the length of a cardiopulmonary resuscitation (CPR) training program can be reduced without ruining its effectiveness. The authors aimed to compare CPR skills 6 months and 1 year after training between shortened chest compression-only CPR training and conventional CPR training. Participants were randomly assigned to either the compression-only CPR group, which underwent a 45-minute training program consisting of chest compressions and automated external defibrillator (AED) use with personal training manikins, or the conventional CPR group, which underwent a 180-minute training program with chest compressions, rescue breathing, and AED use. Participants' resuscitation skills were evaluated 6 months and 1 year after the training. The primary outcome measure was the proportion of appropriate chest compressions 1 year after the training. A total of 146 persons were enrolled, and 63 (87.5%) in the compression-only CPR group and 56 (75.7%) in the conventional CPR group completed the 1-year evaluation. The compression-only CPR group was superior to the conventional CPR group regarding the proportion of appropriate chest compression (mean ± SD = 59.8% ± 40.0% vs. 46.3% ± 28.6%; p = 0.036) and the number of appropriate chest compressions (mean ± SD = 119.5 ± 80.0 vs. 77.2 ± 47.8; p = 0.001). Time without chest compression in the compression-only CPR group was significantly shorter than that in the conventional CPR group (mean ± SD = 11.8 ± 21.1 seconds vs. 52.9 ± 14.9 seconds; p < 0.001). The shortened compression-only CPR training program appears to help the general public retain CPR skills better than the conventional CPR training program. UMIN-CTR UMIN000001675. © 2013 by the Society for Academic Emergency Medicine.

  1. Quality of audio-assisted versus video-assisted dispatcher-instructed bystander cardiopulmonary resuscitation: A systematic review and meta-analysis.

    PubMed

    Lin, Yu-You; Chiang, Wen-Chu; Hsieh, Ming-Ju; Sun, Jen-Tang; Chang, Yi-Chung; Ma, Matthew Huei-Ming

    2018-02-01

    This study aimed to conduct a systematic review and meta-analysis comparing the effect of video-assistance and audio-assistance on quality of dispatcher-instructed cardiopulmonary resuscitation (DI-CPR) for bystanders. Five databases were searched, including PubMed, Cochrane library, Embase, Scopus and NIH clinical trial, to find randomized control trials published before June 2017. Qualitative analysis and meta-analysis were undertaken to examine the difference between the quality of video-instructed and audio-instructed dispatcher-instructed bystander CPR. The database search yielded 929 records, resulting in the inclusion of 9 relevant articles in this study. Of these, 6 were included in the meta-analysis. Initiation of chest compressions was slower in the video-instructed group than in the audio-instructed group (median delay 31.5 s; 95% CI: 10.94-52.09). The difference in the number of chest compressions per minute between the groups was 19.9 (95% CI: 10.50-29.38) with significantly faster compressions in the video-instructed group than in the audio-instructed group (104.8 vs. 80.6). The odds ratio (OR) for correct hand positioning was 0.8 (95% CI: 0.53-1.30) when comparing the audio-instructed and video-instructed groups. The differences in chest compression depth (mm) and time to first ventilation (seconds) between the video-instructed group and audio-instructed group were 1.6 mm (95% CI: -8.75, 5.55) and 7.5 s (95% CI: -56.84, 71.80), respectively. Video-instructed DI-CPR significantly improved the chest compression rate compared to the audio-instructed method, and a trend for correctness of hand position was also observed. However, this method caused a delay in the commencement of bystander-initiated CPR in the simulation setting. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Impact of physical fitness and biometric data on the quality of external chest compression: a randomised, crossover trial

    PubMed Central

    2011-01-01

    Background During circulatory arrest, effective external chest compression (ECC) is a key element for patient survival. In 2005, international emergency medical organisations changed their recommended compression-ventilation ratio (CVR) from 15:2 to 30:2 to acknowledge the vital importance of ECC. We hypothesised that physical fitness, biometric data and gender can influence the quality of ECC. Furthermore, we aimed to determine objective parameters of physical fitness that can reliably predict the quality of ECC. Methods The physical fitness of 30 male and 10 female healthcare professionals was assessed by cycling and rowing ergometry (focussing on lower and upper body, respectively). During ergometry, continuous breath-by-breath ergospirometric measurements and heart rate (HR) were recorded. All participants performed two nine-minute sequences of ECC on a manikin using CVRs of 30:2 and 15:2. We measured the compression and decompression depths, compression rates and assessed the participants' perception of exhaustion and comfort. The median body mass index (BMI; male 25.4 kg/m2 and female 20.4 kg/m2) was used as the threshold for subgroup analyses of participants with higher and lower BMI. Results HR during rowing ergometry at 75 watts (HR75) correlated best with the quality of ECC (r = -0.57, p < 0.05). Participants with a higher BMI and better physical fitness performed better and showed less fatigue during ECC. These results are valid for the entire cohort, as well as for the gender-based subgroups. The compressions of female participants were too shallow and more rapid (mean compression depth was 32 mm and rate was 117/min with a CVR of 30:2). For participants with a lower BMI and higher HR75, the compression depth decreased over time, beginning after four minutes for the 15:2 CVR and after three minutes for the 30:2 CVR. Although found to be more exhausting, a CVR of 30:2 was rated as being more comfortable. Conclusion The quality of the ECC and fatigue can both be predicted by BMI and physical fitness. An evaluation focussing on the upper body may be a more valid predictor of ECC quality than cycling based tests. Our data strongly support the recommendation to relieve ECC providers after two minutes. PMID:22053981

  3. Animation-assisted CPRII program as a reminder tool in achieving effective one-person-CPR performance.

    PubMed

    Choa, Minhong; Cho, Junho; Choi, Young Hwan; Kim, Seungho; Sung, Ji Min; Chung, Hyun Soo

    2009-06-01

    The objective of this study is to compare the skill retention of two groups of lay persons, six months after their last CPR training. The intervention group was provided with animation-assisted CPRII (AA-CPRII) instruction on their cellular phones, and the control group had nothing but what they learned from their previous training. This study was a single blind randomized controlled trial. The participants' last CPR trainings were held at least six months ago. We revised our CPR animation for on-site CPR instruction content emphasizing importance of chest compression. Participants were randomized into two groups, the AA-CPRII group (n=42) and the control group (n=38). Both groups performed three cycles of CPR and their performances were video recorded. These video clips were assessed by three evaluators using a checklist. The psychomotor skills were evaluated using the ResusciAnne SkillReporter. Using the 30-point scoring checklist, the AA-CPRII group had a significantly better score compared to the control group (p<0.001). Psychomotor skills evaluated with the AA-CPRII group demonstrated better performance in hand positioning (p=0.025), compression depth (p=0.035) and compression rate (p<0.001) than the control group. The AA-CPRII group resulted in better checklist scores, including chest compression rate, depth and hand positioning. Animation-assisted CPR could be used as a reminder tool in achieving effective one-person-CPR performance. By installing the CPR instruction on cellular phones and having taught them CPR with it during the training enabled participants to perform better CPR.

  4. High-quality cardiopulmonary resuscitation.

    PubMed

    Nolan, Jerry P

    2014-06-01

    The quality of cardiopulmonary resuscitation (CPR) impacts on outcome after cardiac arrest. This review will explore the factors that contribute to high-quality CPR and the metrics that can be used to monitor performance. A recent consensus statement from North America defined five key components of high-quality CPR: minimizing interruptions in chest compressions, providing compressions of adequate rate and depth, avoiding leaning on the chest between compressions, and avoiding excessive ventilation. Studies have shown that real-time feedback devices improve the quality of CPR and, in one before-and-after study, outcome from out-of-hospital cardiac arrest. There is evidence for increasing survival rates following out-of-hospital cardiac arrest and this is associated with increasing rates of bystander CPR. The quality of CPR provided by healthcare professionals can be improved with real-time feedback devices. The components of high-quality CPR and the metrics that can be measured and fed back to healthcare professionals have been defined by expert consensus. In the future, real-time feedback based on the physiological responses to CPR may prove more effective.

  5. Peyton's 4-Steps-Approach in comparison: Medium-term effects on learning external chest compression – a pilot study

    PubMed Central

    Münster, Tobias; Stosch, Christoph; Hindrichs, Nina; Franklin, Jeremy; Matthes, Jan

    2016-01-01

    Introduction: The external chest compression is a very important skill required to maintain a minimum of circulation during cardiac arrest until further medical procedures can be taken. Peyton’s 4-Steps-Approach is one method of skill training, the four steps being: Demonstration, Deconstruction, Comprehension and Execution. Based on CPR skill training, this method is widely, allegedly predominantly used, although there are insufficient studies on Peyton’s 4-Steps-Approach for skill training in CPR in comparison with other methods of skill training. In our study, we compared the medium- term effects on learning external chest compression with a CPR training device in three different groups: PEY (Peyton’s 4-Steps-Approach), PMOD (Peyton’s 4-Steps-Approach without Step 3) and STDM, the standard model, according to the widely spread method “see one, do one” (this is equal to Peyton’s step 1 and 3). Material and Methods: This prospective and randomised pilot study took place during the summer semester of 2009 at the SkillsLab and Simulation Centre of the University of Cologne (Kölner interprofessionelles Skills Lab und Simulationszentrum - KISS). The subjects were medical students (2nd and 3rd semester). They volunteered for the study and were randomised in three parallel groups, each receiving one of the teaching methods mentioned above. One week and 5/6 months after the intervention, an objective, structured single assessment was taken. Compression rate, compression depth, correct compressions, and the sum of correct checklist items were recorded. Additionally, we compared cumulative percentages between the groups based on the correct implementation of the resuscitation guidelines during that time. Results: The examined sample consisted of 134 subjects (68% female; age 22±4; PEY: n=62; PMOD: n=31; STDM: n=41). There was no difference between the groups concerning age, gender, pre-existing experience in CPR or time of last CPR course. The only significant difference between the groups was the mean compression rate (bpm): Group 1 (PEY) with 99±17 bpm, Group 2 (PMOD) with 101±16 bpm and Group 3 (STDM) with 90±16 bpm (p=0,007 for Group 3 vs. Group 1 and Group 3 vs. Group 2, Mann-Whitney- U-Test). We observed no significant differences between the groups after the second assessment. Conclusion: Our study showed that there are no essential differences in external chest compression during CPR performed by medical students dependent on the teaching method (Peyton vs. “Non-Peyton”) implemented with regard to the medium-term effects. The absence of benefits could possibly be due to the simplicity of external chest compression. PMID:27579360

  6. A hemodynamic-directed approach to pediatric cardiopulmonary resuscitation (HD-CPR) improves survival.

    PubMed

    Morgan, Ryan W; Kilbaugh, Todd J; Shoap, Wesley; Bratinov, George; Lin, Yuxi; Hsieh, Ting-Chang; Nadkarni, Vinay M; Berg, Robert A; Sutton, Robert M

    2017-02-01

    Most pediatric in-hospital cardiac arrests (IHCAs) occur in ICUs where invasive hemodynamic monitoring is frequently available. Titrating cardiopulmonary resuscitation (CPR) to the hemodynamic response of the individual improves survival in preclinical models of adult cardiac arrest. The objective of this study was to determine if titrating CPR to systolic blood pressure (SBP) and coronary perfusion pressure (CoPP) in a pediatric porcine model of asphyxia-associated ventricular fibrillation (VF) IHCA would improve survival as compared to traditional CPR. After 7min of asphyxia followed by VF, 4-week-old piglets received either hemodynamic-directed CPR (HD-CPR; compression depth titrated to SBP of 90mmHg and vasopressor administration to maintain CoPP ≥20mmHg); or Standard Care (compression depth 1/3 of the anterior-posterior chest diameter and epinephrine every 4min). All animals received CPR for 10min prior to the first defibrillation attempt. CPR was continued for a maximum of 20min. Protocolized intensive care was provided to all surviving animals for 4h. The primary outcome was 4-h survival. Survival rate was greater with HD-CPR (12/12) than Standard Care (6/10; p=0.03). CoPP during HD-CPR was higher compared to Standard Care (point estimate +8.1mmHg, CI 95 : 0.5-15.8mmHg; p=0.04). Chest compression depth was lower with HD-CPR than Standard Care (point estimate -14.0mm, CI95: -9.6 to -18.4mm; p<0.01). Prior to the first defibrillation attempt, more vasopressor doses were administered with HD-CPR vs. Standard Care (median 5 vs. 2; p<0.01). Hemodynamic-directed CPR improves short-term survival compared to standard depth-targeted CPR in a porcine model of pediatric asphyxia-associated VF IHCA. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. A Hemodynamic-Directed Approach to Pediatric Cardiopulmonary Resuscitation (HD-CPR) Improves Survival

    PubMed Central

    Morgan, Ryan W.; Kilbaugh, Todd J.; Shoap, Wesley; Bratinov, George; Lin, Yuxi; Hsieh, Ting-Chang; Nadkarni, Vinay M.; Berg, Robert A.; Sutton, Robert M.

    2016-01-01

    Aim Most pediatric in-hositalcardiac arrests(IHCAs) occur in ICUs where invasive hemodynamic monitoring is frequently available. Titrating cardiopulmonary resuscitation (CPR) to the hemodynamic response of the individual improves survival in preclinical models of adult cardiac arrest. The objective of this study was to determine if titrating CPR to systolic blood pressure (SBP) and coronary perfusion pressure (CoPP) in a pediatric porcine model of asphyxia-associated ventricular fibrillation (VF) IHCA would improve survival as compared to traditional CPR. Methods After 7 minutes of asphyxia followed by VF, 4-week-old piglets received either Hemodynamic-Directed CPR (HD-CPR; compression depth titrated to SBP of 90mmHg and vasopressor administration to maintain CoPP ≥20mmHg); or Standard Care (compression depth 1/3 of the anterior-posterior chest diameter and epinephrine every 4 minutes). All animals received CPR for 10 minutes prior to the first defibrillation attempt. CPR was continued for a maximum of 20 minutes. Protocolized intensive care was provided to all surviving animals for 4 hours. The primary outcome was 4-hour survival. Results Survival rate was greater with HD-CPR (12/12) than Standard Care (6/10; p=0.03). CoPP during HD-CPR was higher compared to Standard Care (point estimate +8.1mmHg, CI95: 0.5–15.8mmHg; p=0.04). Chest compression depth was lower with HD-CPR than Standard Care (point estimate 14.0mm, CI95: 9.6–18.4mm; p<0.01). Prior to the first defibrillation attempt, more vasopressor doses were administered with HD-CPR versus Standard Care (median 5 versus 2; p<0.01). Conclusions Hemodynamic-directed CPR improves short-term survival compared to standard depth-targeted CPR in a porcine model of pediatric asphyxia-associated VF IHCA. PMID:27923692

  8. Modern BLS, dispatch and AED concepts.

    PubMed

    Koster, Rudolph W

    2013-09-01

    Basic Life Support has changed significantly over the last 15 years. Evidence-based changes in recommendations involved compression rate, compression depth and the ratio between compressions and ventilations. There is much evidence that early basic life support increases the probability of survival two- to three-fold. Recognition of a cardiac arrest remains challenging for witness and dispatcher. Educating the public in basic life support and recognition of cardiac arrest are key factors in improving survival of cardiac arrest. The large differences in survival between countries and regions clearly indicate that education and implementation must be high on the agenda in each community. Dispatchers play an increasingly important role in the process, both in rapid recognition of the cardiac arrest as well as giving telephone guidance to those bystanders that had not followed a training in basic life support. Those instructions should only instruct to deliver chest compressions. For those who have been trained in BLS and who are willing to give full CPR, should administer ventilations and chest compressions according to the guidelines. The AED plays a key role in early management of cardiac arrest and can substantially contribute to better survival. Logistics of placement of AEDs and the optimal way to bring AEDs to a victim require much more efforts, especially for victims in residential area's, where the great majority of cases of cardiac arrest occur. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Impacts to the chest of PMHSs - Influence of impact location and load distribution on chest response.

    PubMed

    Holmqvist, Kristian; Svensson, Mats Y; Davidsson, Johan; Gutsche, Andreas; Tomasch, Ernst; Darok, Mario; Ravnik, Dean

    2016-02-01

    The chest response of the human body has been studied for several load conditions, but is not well known in the case of steering wheel rim-to-chest impact in heavy goods vehicle frontal collisions. The aim of this study was to determine the response of the human chest in a set of simulated steering wheel impacts. PMHS tests were carried out and analysed. The steering wheel load pattern was represented by a rigid pendulum with a straight bar-shaped front. A crash test dummy chest calibration pendulum was utilised for comparison. In this study, a set of rigid bar impacts were directed at various heights of the chest, spanning approximately 120mm around the fourth intercostal space. The impact energy was set below a level estimated to cause rib fracture. The analysed results consist of responses, evaluated with respect to differences in the impacting shape and impact heights on compression and viscous criteria chest injury responses. The results showed that the bar impacts consistently produced lesser scaled chest compressions than the hub; the Middle bar responses were around 90% of the hub responses. A superior bar impact provided lesser chest compression; the average response was 86% of the Middle bar response. For inferior bar impacts, the chest compression response was 116% of the chest compression in the middle. The damping properties of the chest caused the compression to decrease in the high speed bar impacts to 88% of that in low speed impacts. From the analysis it could be concluded that the bar impact shape provides lower chest criteria responses compared to the hub. Further, the bar responses are dependent on the impact location of the chest. Inertial and viscous effects of the upper body affect the responses. The results can be used to assess the responses of human substitutes such as anthropomorphic test devices and finite element human body models, which will benefit the development process of heavy goods vehicle safety systems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. The impact of ultra-brief chest compression-only CPR video training on responsiveness, compression rate, and hands-off time interval among bystanders in a shopping mall.

    PubMed

    Panchal, Ashish R; Meziab, Omar; Stolz, Uwe; Anderson, Wes; Bartlett, Mitchell; Spaite, Daniel W; Bobrow, Bentley J; Kern, Karl B

    2014-09-01

    Recent studies have demonstrated higher-quality chest compressions (CCs) following a 60 s ultra-brief video (UBV) on compression-only CPR (CO-CPR). However, the effectiveness of UBVs as a CPR-teaching tool for lay bystanders in public venues remains unknown. Determine whether an UBV is effective in teaching laypersons CO-CPR in a public setting and if viewing leads to superior responsiveness and CPR skills. Adult lay bystanders were enrolled in a public shopping mall and randomized to: (1) Control (CTR): sat idle for 60 s; (2) UBV: watched a 60 s UBV on CO-CPR. Subjects were read a scenario detailing a sudden collapse in the mall and asked to do what they "thought was best" on a mannequin. Performance measures were recorded for 2 min: responsiveness (time to call 911 and first CCs) and CPR quality [CC depth, rate, hands-off interval (time without CC after first CC)]. One hundred subjects were enrolled. Demographics were similar between groups. UBV subjects called 911 more frequently (percent difference: 31%) and initiated CCs sooner in the arrest scenario (median difference (MD): 5 s). UBV cohort had increased CC rate (MD: 19 cpm) and decreased hands-off interval (MD: 27 s). There was no difference in CC depth. Bystanders with UBV training in a shopping mall had significantly improved responsiveness, CC rate, and decreased hands-off interval. Given the short length of training, UBV may have potential as a ubiquitous intervention for public venues to help improve bystander reaction to arrest and CO-CPR performance. Published by Elsevier Ireland Ltd.

  11. Mechanical versus manual chest compressions for out-of-hospital cardiac arrest: a meta-analysis of randomized controlled trials

    PubMed Central

    Tang, Lu; Gu, Wan-Jie; Wang, Fei

    2015-01-01

    Recent evidence regarding mechanical chest compressions in out-of-hospital cardiac arrest (OHCA) is conflicting. The objective of this study was to perform a meta-analysis of randomized controlled trials (RCTs) to compare the effect of mechanical versus manual chest compressions on resuscitation outcomes in OHCA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, and the ClinicalTrials.gov registry were searched. In total, five RCTs with 12,510 participants were included. Compared with manual chest compressions, mechanical chest compressions did not significantly improve survival with good neurological outcome to hospital discharge (relative risks (RR) 0.80, 95% CI 0.61–1.04, P = 0.10; I2 = 65%), return of spontaneous circulation (RR 1.02, 95% CI 0.95–1.09, P = 0.59; I2 = 0%), or long-term (≥6 months) survival (RR 0.96, 95% CI 0.79–1.16, P = 0.65; I2 = 16%). In addition, mechanical chest compressions were associated with worse survival to hospital admission (RR 0.94, 95% CI 0.89–1.00, P = 0.04; I2 = 0%) and to hospital discharge (RR 0.88, 95% CI 0.78–0.99, P = 0.03; I2 = 0%). Based on the current evidence, widespread use of mechanical devices for chest compressions in OHCA cannot be recommended. PMID:26503429

  12. Comparison between manual and mechanical chest compressions during resuscitation in a pediatric animal model of asphyxial cardiac arrest

    PubMed Central

    Fernández, Sarah N.; González, Rafael; Solana, María J.; Urbano, Javier; Toledo, Blanca

    2017-01-01

    Aims Chest compressions (CC) during cardiopulmonary resuscitation are not sufficiently effective in many circumstances. Mechanical CC could be more effective than manual CC, but there are no studies comparing both techniques in children. The objective of this study was to compare the effectiveness of manual and mechanical chest compressions with Thumper device in a pediatric cardiac arrest animal model. Material and methods An experimental model of asphyxial cardiac arrest (CA) in 50 piglets (mean weight 9.6 kg) was used. Animals were randomized to receive either manual CC or mechanical CC using a pediatric piston chest compressions device (Life-Stat®, Michigan Instruments). Mean arterial pressure (MAP), arterial blood gases and end-tidal CO2 (etCO2) values were measured at 3, 9, 18 and 24 minutes after the beginning of resuscitation. Results There were no significant differences in MAP, DAP, arterial blood gases and etCO2 between chest compression techniques during CPR. Survival rate was higher in the manual CC (15 of 30 = 50%) than in the mechanical CC group (3 of 20 = 15%) p = 0.016. In the mechanical CC group there was a non significant higher incidence of haemorrhage through the endotracheal tube (45% vs 20%, p = 0.114). Conclusions In a pediatric animal model of cardiac arrest, mechanical piston chest compressions produced lower survival rates than manual chest compressions, without any differences in hemodynamic and respiratory parameters. PMID:29190801

  13. Comparison of Ventilation and Cardiac Compressions When Utilizing the Impact Model 730 Automatic Transport Ventilator Versus a Conventional Bag Valve With a Facemask in a Model of Adult Cadiopulmonary Arrest

    DTIC Science & Technology

    2005-10-25

    Chest compression , Ventilation 2P251107 256Page 2 1. Introduction During the initial stages of cardiopulmonary resuscitation ( CPR ), ventilation is...a metronome to facilitate chest compression timing. Twenty-eight nurses alternated performing 4 minutes of CPR using the BVM or Impact 730 to deliver... Chest compression and ventilation rates during cardiopulmonary resuscitation : the effects of audible tone guidance. Academic Emergency Medicine

  14. The influence of scenario-based training and real-time audiovisual feedback on out-of-hospital cardiopulmonary resuscitation quality and survival from out-of-hospital cardiac arrest.

    PubMed

    Bobrow, Bentley J; Vadeboncoeur, Tyler F; Stolz, Uwe; Silver, Annemarie E; Tobin, John M; Crawford, Scott A; Mason, Terence K; Schirmer, Jerome; Smith, Gary A; Spaite, Daniel W

    2013-07-01

    We assess whether an initiative to optimize out-of-hospital provider cardiopulmonary resuscitation (CPR) quality is associated with improved CPR quality and increased survival from out-of-hospital cardiac arrest. This was a before-after study of consecutive adult out-of-hospital cardiac arrest. Data were obtained from out-of-hospital forms and defibrillators. Phase 1 included 18 months with real-time audiovisual feedback disabled (October 2008 to March 2010). Phase 2 included 16 months (May 2010 to September 2011) after scenario-based training of 373 professional rescuers and real-time audiovisual feedback enabled. The effect of interventions on survival to hospital discharge was assessed with multivariable logistic regression. Multiple imputation of missing data was used to analyze the effect of interventions on CPR quality. Analysis included 484 out-of-hospital cardiac arrest patients (phase 1 232; phase 2 252). Median age was 68 years (interquartile range 56-79); 66.5% were men. CPR quality measures improved significantly from phase 1 to phase 2: Mean chest compression rate decreased from 128 to 106 chest compressions per minute (difference -23 chest compressions; 95% confidence interval [CI] -26 to -19 chest compressions); mean chest compression depth increased from 1.78 to 2.15 inches (difference 0.38 inches; 95% CI 0.28 to 0.47 inches); median chest compression fraction increased from 66.2% to 83.7% (difference 17.6%; 95% CI 15.0% to 20.1%); median preshock pause decreased from 26.9 to 15.5 seconds (difference -11.4 seconds; 95% CI -15.7 to -7.2 seconds), and mean ventilation rate decreased from 11.7 to 9.5/minute (difference -2.2/minute; 95% CI -3.9 to -0.5/minute). All-rhythms survival increased from phase 1 to phase 2 (20/231, 8.7% versus 35/252, 13.9%; difference 5.2%; 95% CI -0.4% to 10.8%), with an adjusted odds ratio of 2.72 (95% CI 1.15 to 6.41), controlling for initial rhythm, witnessed arrest, age, minimally interrupted cardiac resuscitation protocol compliance, and provision of therapeutic hypothermia. Witnessed arrests/shockable rhythms survival was 26.3% (15/57) for phase 1 and 55.6% (20/36) for phase 2 (difference 29.2%; 95% CI 9.4% to 49.1%). Implementation of resuscitation training combined with real-time audiovisual feedback was independently associated with improved CPR quality, an increase in survival, and favorable functional outcomes after out-of-hospital cardiac arrest. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  15. Development and validation of an improved mechanical thorax for simulating cardiopulmonary resuscitation with adjustable chest stiffness and simulated blood flow.

    PubMed

    Eichhorn, Stefan; Spindler, Johannes; Polski, Marcin; Mendoza, Alejandro; Schreiber, Ulrich; Heller, Michael; Deutsch, Marcus Andre; Braun, Christian; Lange, Rüdiger; Krane, Markus

    2017-05-01

    Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR efficacy. Based on thoracic stiffness data measured in human cadavers, such a model was constructed using valve-controlled pneumatic pistons and an artificial heart. This model offers two realistic levels of chest elasticity, with a blood flow apparatus that reflects compressive depth and waveform changes. We conducted CPR at opposing levels of physiologic stiffness, using a LUCAS device, a motor-driven plunger, and a group of volunteers. In high-stiffness mode, blood flow generated by volunteers was significantly less after just 2min of CPR, whereas flow generated by LUCAS device was superior by comparison. Optimal blood flow was obtained via motor-driven plunger, with trapezoidal waveform. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  16. Traumatic Pancreatitis: A Rare Complication of Cardiopulmonary Resuscitation.

    PubMed

    Aziz, Muhammad

    2017-08-17

    An elderly gentleman was successfully revived after undergoing cardiopulmonary resuscitation (CPR) for cardiac arrest. Post CPR, the patient developed acute pancreatitis which was likely complication of inappropriately delivered chest compressions which caused further complications and resulted in the death of the patient. This case underlines the importance of quality chest compressions that includes correct placement of hands by the operator giving chest compressions to avoid lethal injuries to the receiver.

  17. Life-threatening hemothorax due to azygos vein rupture after chest compression during cardiopulmonary resuscitation.

    PubMed

    Yang, Euiseok; Jeong, WonJoon; Lee, JunWan; Kim, SeungWhan

    2014-11-01

    Hemothorax is not an uncommon cardiopulmonary resuscitation(CPR)–related complication. But hemothorax related to azygos vein injury (AVI) is a rare condition following blunt chest trauma, with no report of CPR-related AVI in the literature. We present a case of azygosve in rupture in a middle-aged woman after repeated chest compression during 1 hour of CPR. She eventually presented with massive hemothorax due to azygos vein rupture diagnosed by computed tomography (CT). When faced with a patient with massive hemothorax after chest compression, azygos vein rupture should be considered as a complication.

  18. Poor chest compression quality with mechanical compressions in simulated cardiopulmonary resuscitation: a randomized, cross-over manikin study.

    PubMed

    Blomberg, Hans; Gedeborg, Rolf; Berglund, Lars; Karlsten, Rolf; Johansson, Jakob

    2011-10-01

    Mechanical chest compression devices are being implemented as an aid in cardiopulmonary resuscitation (CPR), despite lack of evidence of improved outcome. This manikin study evaluates the CPR-performance of ambulance crews, who had a mechanical chest compression device implemented in their routine clinical practice 8 months previously. The objectives were to evaluate time to first defibrillation, no-flow time, and estimate the quality of compressions. The performance of 21 ambulance crews (ambulance nurse and emergency medical technician) with the authorization to perform advanced life support was studied in an experimental, randomized cross-over study in a manikin setup. Each crew performed two identical CPR scenarios, with and without the aid of the mechanical compression device LUCAS. A computerized manikin was used for data sampling. There were no substantial differences in time to first defibrillation or no-flow time until first defibrillation. However, the fraction of adequate compressions in relation to total compressions was remarkably low in LUCAS-CPR (58%) compared to manual CPR (88%) (95% confidence interval for the difference: 13-50%). Only 12 out of the 21 ambulance crews (57%) applied the mandatory stabilization strap on the LUCAS device. The use of a mechanical compression aid was not associated with substantial differences in time to first defibrillation or no-flow time in the early phase of CPR. However, constant but poor chest compressions due to failure in recognizing and correcting a malposition of the device may counteract a potential benefit of mechanical chest compressions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. CPR feedback/prompt device improves the quality of hands-only CPR performed in manikin by laypersons following the 2015 AHA guidelines.

    PubMed

    Liu, Yuanshan; Huang, Zitong; Li, Heng; Zheng, Guanghui; Ling, Qin; Tang, Wanchun; Yang, Zhengfei

    2018-03-06

    We investigated the effects of a cardiopulmonary resuscitation (CPR) feedback/prompt device on the quality of chest compression (CC) during hands-only CPR following the 2015 AHA guidelines. A total of 124 laypersons were randomly assigned into three groups. The first (n=42) followed the 2010 guidelines, the second (n=42) followed the 2015 guidelines with no feedback/prompt device, the third (n=40) followed the 2015 guidelines with a feedback/prompt device (2015F). Participants underwent manual CPR training and took a written basic life support examination, then required to perform 2min of hands-only CPR monitored by a CPR feedback/prompt device. The quality of CPR was quantified as the percentage of correct CCs (mean CC depth and rate, complete recoil and chest compression fraction (CCF)) per 20s, as recorded by the CPR feedback/prompt device. Significantly higher correct ratios of CC, CC depth, and rate were achieved in the 2010 group in each minute vs the 2015 group. The greater mean CC depth and rate were observed in the 2015F group vs the 2015 group. The correct ratio of CC was significantly higher in the 2015F group vs the 2015 group. CCF was also significantly higher in the 2015F group vs the 2015 group in the last 20s of CPR. It is difficult for a large percentage of laypersons to achieve the targets of CC depth and rate following the 2015 AHA guidelines. CPR feedback/prompt devices significantly improve the quality of hands-only CPR performance by laypersons following the standards of the 2015 AHA guidelines. Copyright © 2017. Published by Elsevier Inc.

  20. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    NASA Astrophysics Data System (ADS)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  1. The quality of a newly developed infant chest compression method applied by paramedics: a randomised crossover manikin trial.

    PubMed

    Smereka, Jacek; Kasiński, Mariusz; Smereka, Adam; Ładny, Jerzy R; Szarpak, Łukasz

    2017-01-01

    The aetiology of sudden cardiac arrest in infants is different from that in adults, with respiratory failure, sudden infant death syndrome, and drowning being the primary causes in the former. According to the European Resuscitation Council (ERC) and American Heart Association (AHA) recommendations, the quality of chest compressions (CC) is a key element affecting the effectiveness of cardiopulmonary resuscitation (CPR). The current ERC and AHA guidelines recommend the 'two-finger technique' (TFT) or 'two-thumb encircling hands technique' (TTHT) for external CCs during infant CPR. The aim of the randomised crossover manikin trial was to assess the CC quality during simulated resuscitation in infants performed by paramedics. A prospective, randomised, crossover, single-centre study was conducted between June and August 2016. The study material consisted of 120 fully trained and licensed paramedics (39 females, 32.5%) with a minimum of five years of professional experience (mean 7.5 ± 4.8 years) in emergency medicine (mean age, 30.5 ± 5.5 years). The participants performed CCs using three techniques: TFT (the rescuer compresses the sternum with the tips of two fingers); TTHT; and the 'new two-thumb technique' (nTTT). The novel method of CCs in an infant consists of using two thumbs directed at the angle of 90 degrees to the chest while closing the fingers of both hands in a fist. The median CC rate when using the TFT, the TTHT, and nTTT methods varied and amounted to 134 min-1 vs. 126 min-1 vs. 114 min-1, respectively. There was a statistically significant difference in the median CC frequency between TFT and TTHT (p < 0.001), TFT and nTTT (p < 0.001), and between TTHT and nTTT (p < 0.001). The highest percentage of compressions with the frequency recommended by the ERC guidelines (100-120 min-1) was achieved by the study participants only with the nTTT. The median CC depth during the TFT was 28 mm (interquartile range [IQR] 27-30 mm) and was significantly lower than in the static TTHT (40.5 [IQR 39-41] mm; p < 0.001) and nTTT (40 [IQR 39-41] mm; p < 0.001). The percentage of adequate depth CCs was correctly obtained with TTHT and nTTT. The largest proportion of total decompression of the chest was observed with the nTTT technique (96 [IQR 96-98] %), followed by TFT (95.5 [IQR 85.5-99] %) and TTHT (5 [IQR 3-7] %). In all scenarios, the correct placement of the CC point was achieved in more than 90% of cases. Our novel infant CC method provides the highest percentage of CCs with the frequency recommended by the ERC guidelines as compared with standard techniques. It also allows optimal CC depth.

  2. [New Insights into Maternal Cardiopulmonary Resuscitation--Significance of Simulation Research and Training].

    PubMed

    Komasawa, Nobuyasu; Fujiwara, Shunsuke; Majima, Nozomi; Minami, Toshiaki

    2015-08-01

    Pregnancy-related mortality, estimated to occur in approximately 1: 50,000 deliveries, is rare in developed countries. The 2010 American Heart Association (AHA) Guidelines for Resuscitation emphasize the importance of high-quality chest compression as a key determinant of successful cardiopulmonary resuscitation. During pregnancy, the uterus can compress the inferior vena cava, impeding venous return and thereby reducing stroke volume and cardiac output. To maximize the effectiveness of chest compressions in pregnancy, the AHA guidelines recommend the 27-30 degrees left-lateral tilt (LLT) position. When CPR is performed on parturients in the LLT position, chest compressions will probably be more effective if performed with the operator standing on the left side of the patient. The videolaryngoscope Pentax-AWS Airwayscope (AWS) was found to be an effective tool for airway management during chest compressions in 27 LLT simulations, suggesting that the AWS may be a useful device for airway management during maternal resuscitation.

  3. Effect of timing and duration of a single chest compression pause on short-term survival following prolonged ventricular fibrillation.

    PubMed

    Walcott, Gregory P; Melnick, Sharon B; Walker, Robert G; Banville, Isabelle; Chapman, Fred W; Killingsworth, Cheryl R; Ideker, Raymond E

    2009-04-01

    Pauses during chest compressions are thought to have a detrimental effect on resuscitation outcome. The Guidelines 2005 have recently eliminated the post-defibrillation pause. Previous animal studies have shown that multiple pauses of increasing duration decrease resuscitation success. We investigated the effect of varying the characteristics of a single pause near defibrillation on resuscitation outcome. Part A: 48 swine were anesthetized, fibrillated for 7min and randomized. Chest compressions were initiated for 90s followed by defibrillation and then resumption of chest compressions. Four groups were studied-G2000: 40s pause beginning 20s before, and ending 20s after defibrillation, A1: a 20s pause just before defibrillation, A2: a 20s pause ending 30s prior to defibrillation, and group A3: a 10s pause ending 30s prior to defibrillation. Part B: 12 swine (Group B) were studied with a protocol identical to Part A but with no pause in chest compressions. Primary endpoint was survival to 4h. The survival rate was significantly higher for groups A1, A2, A3, and B (5/12, 7/12, 5/12, and 5/12 survived) than for the G2000 group (0/12, p<0.05). Survival did not differ significantly among groups A1, A2, A3, and B. These results suggest that the Guidelines 2005 recommendation to omit the post-shock pulse check and immediately resume chest compressions may be an important resuscitation protocol change. However, these results also suggest that clinical maneuvers further altering a single pre-shock chest compression pause provide no additional benefit.

  4. Effect of timing and duration of a single chest compression pause on short-term survival following prolonged ventricular fibrillation☆

    PubMed Central

    Walcott, Gregory P.; Melnick, Sharon B.; Walker, Robert G.; Banville, Isabelle; Chapman, Fred W.; Killingsworth, Cheryl R.; Ideker, Raymond E.

    2014-01-01

    Background Pauses during chest compressions are thought to have a detrimental effect on resuscitation outcome. The Guidelines 2005 have recently eliminated the post-defibrillation pause. Previous animal studies have shown that multiple pauses of increasing duration decrease resuscitation success. We investigated the effect of varying the characteristics of a single pause near defibrillation on resuscitation outcome. Methods Part A: 48 swine were anesthetized, fibrillated for 7 min and randomized. Chest compressions were initiated for 90 s followed by defibrillation and then resumption of chest compressions. Four groups were studied—G2000: 40 s pause beginning 20 s before, and ending 20 s after defibrillation, A1: a 20 s pause just before defibrillation, A2: a 20 s pause ending 30 s prior to defibrillation, and group A3: a 10 s pause ending 30 s prior to defibrillation. Part B: 12 swine (Group B) were studied with a protocol identical to Part A but with no pause in chest compressions. Primary endpoint was survival to 4 h. Results The survival rate was significantly higher for groups A1, A2, A3, and B (5/12, 7/12, 5/12, and 5/12 survived) than for the G2000 group (0/12, p < 0.05). Survival did not differ significantly among groups A1, A2, A3, and B. Conclusions These results suggest that the Guidelines 2005 recommendation to omit the post-shock pulse check and immediately resume chest compressions may be an important resuscitation protocol change. However, these results also suggest that clinical maneuvers further altering a single pre-shock chest compression pause provide no additional benefit. PMID:19185411

  5. The impact of manual defibrillation technique on no-flow time during simulated cardiopulmonary resuscitation.

    PubMed

    Perkins, Gavin D; Davies, Robin P; Soar, Jasmeet; Thickett, David R

    2007-04-01

    Rapid defibrillation is the most effective strategy for establishing return of spontaneous circulation following cardiac arrest due to ventricular fibrillation. The aim of this study is to measure the delay due to of charging the defibrillator during chest compression in an attempt to reduce the duration of the pre-shock pause in between cessation of chest compressions and shock delivery as advocated by the American Heart Association (AHA) guidelines compared to charging the defibrillator immediately following rhythm analysis without resuming chest compressions as recommended by the European Resuscitation Council (ERC). This was a randomised controlled cross over trial comparing pre-shock pause times when defibrillation was performed on a manikin according to the AHA and ERC guidelines using paddles and hands free defibrillation systems. The pre-shock pause between cessation of chest compression and shock delivery was significantly different between techniques (Friedman test, P<0.0001). ERC paddles technique had the greatest pre-shock pause (7.4 s [6.7-11.2]) followed by ERC hands free (7.0 s [6.5-8.5]) and AHA paddles (1.6 s [1.1-2.3]). AHA hands free took the least amount of time (1.5 s [0.8-1.5]). Extrapolating these data to older defibrillators with longer charge times saw pre-shock pause intervals of 9 s (Codemaster XL) and 12 s (Lifepak 20) with the ERC approach. This study demonstrated clinically significant delays to defibrillation by analysing and charging the defibrillator without performing concurrent chest compressions. In a simulated scenario, charging the defibrillator whilst performing chest compressions was perceived as safe and significantly reduced the pre-shock pause between cessation of chest compression and shock delivery.

  6. Viewing an ultra-brief chest compression only video improves some measures of bystander CPR performance and responsiveness at a mass gathering event.

    PubMed

    Beskind, Daniel L; Stolz, Uwe; Thiede, Rebecca; Hoyer, Riley; Robertson, Whitney; Brown, Jeffrey; Ludgate, Melissa; Tiutan, Timothy; Shane, Romy; McMorrow, Deven; Pleasants, Michael; Kern, Karl B; Panchal, Ashish R

    2017-09-01

    CPR training at mass gathering events is an important part of health initiatives to improve cardiac arrest survival. However, it is unclear whether training lay bystanders using an ultra-brief video at a mass gathering event improves CPR quality and responsiveness. To determine if showing a chest-compression only (CCO) Ultra-Brief Video (UBV) at a mass gathering event is effective in teaching lay bystanders CCO-CPR. Prospective control trial in adults (age >18) who attended either a women's University of Arizona or a men's Phoenix Suns basketball game. Participants were evaluated using a standardized cardiac arrest scenario with Laerdal Skillreporter™ mannequins. CPR responsiveness (calling 911, time to calling 911, starting compressions within two minutes) and quality (compression rate, depth, hands-off time) were assessed for participants and data collected at Baseline and Post-intervention. Different participants were tested before and after the exposure of the UBV. Data were analyzed via the intention to treat principle using logistic regression for binary outcomes and median regression for continuous outcomes, controlling for clustering by venue. A total of 96 people were consented (Baseline=45; Post intervention=51). CPR responsiveness post intervention improved with faster time to calling 911 (s) and time to starting compressions (sec). Likewise, CPR quality improved with deeper compressions and improved hands-off time. Showing a UBV at a mass gathering sporting event is associated with improved CPR responsiveness and performance for lay bystanders. This data provides further support for the use of mass media interventions. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Retention of basic life support knowledge, self-efficacy and chest compression performance in Thai undergraduate nursing students.

    PubMed

    Partiprajak, Suphamas; Thongpo, Pichaya

    2016-01-01

    This study explored the retention of basic life support knowledge, self-efficacy, and chest compression performance among Thai nursing students at a university in Thailand. A one-group, pre-test and post-test design time series was used. Participants were 30 nursing students undertaking basic life support training as a care provider. Repeated measure analysis of variance was used to test the retention of knowledge and self-efficacy between pre-test, immediate post-test, and re-test after 3 months. A Wilcoxon signed-rank test was used to compare the difference in chest compression performance two times. Basic life support knowledge was measured using the Basic Life Support Standard Test for Cognitive Knowledge. Self-efficacy was measured using the Basic Life Support Self-Efficacy Questionnaire. Chest compression performance was evaluated using a data printout from Resusci Anne and Laerdal skillmeter within two cycles. The training had an immediate significant effect on the knowledge, self-efficacy, and skill of chest compression; however, the knowledge and self-efficacy significantly declined after post-training for 3 months. Chest compression performance after training for 3 months was positively retaining compared to the first post-test but was not significant. Therefore, a retraining program to maintain knowledge and self-efficacy for a longer period of time should be established after post-training for 3 months. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. A mechanical chest compressor closed-loop controller with an effective trade-off between blood flow improvement and ribs fracture reduction.

    PubMed

    Zhang, Guang; Wu, Taihu; Song, Zhenxing; Wang, Haitao; Lu, Hengzhi; Wang, Yalin; Wang, Dan; Chen, Feng

    2015-06-01

    Chest compression (CC) is a significant emergency medical procedure for maintaining circulation during cardiac arrest. Although CC produces the necessary blood flow for patients with heart arrest, improperly deep CC will contribute significantly to the risk of chest injury. In this paper, an optimal CC closed-loop controller for a mechanical chest compressor (OCC-MCC) was developed to provide an effective trade-off between the benefit of improved blood perfusion and the risk of ribs fracture. The trade-off performance of the OCC-MCC during real automatic mechanical CCs was evaluated by comparing the OCC-MCC and the traditional mechanical CC method (TMCM) with a human circulation hardware model based on hardware simulations. A benefit factor (BF), risk factor (RF) and benefit versus risk index (BRI) were introduced in this paper for the comprehensive evaluation of risk and benefit. The OCC-MCC was developed using the LabVIEW control platform and the mechanical chest compressor (MCC) controller. PID control is also employed by MCC for effective compression depth regulation. In addition, the physiological parameters model for MCC was built based on a digital signal processor for hardware simulations. A comparison between the OCC-MCC and TMCM was then performed based on the simulation test platform which is composed of the MCC, LabVIEW control platform, physiological parameters model for MCC and the manikin. Compared with the TMCM, the OCC-MCC obtained a better trade-off and a higher BRI in seven out of a total of nine cases. With a higher mean value of cardiac output (1.35 L/min) and partial pressure of end-tidal CO2 (15.7 mmHg), the OCC-MCC obtained a larger blood flow and higher BF than TMCM (5.19 vs. 3.41) in six out of a total of nine cases. Although it is relatively difficult to maintain a stable CC depth when the chest is stiff, the OCC-MCC is still superior to the TMCM for performing safe and effective CC during CPR. The OCC-MCC is superior to the TMCM in performing safe and effective CC during CPR and can be incorporated into the current version of mechanical CC devices for high quality CPR, in both in-hospital and out-of-hospital CPR settings.

  9. Tracheal intubation using Macintosh and 2 video laryngoscopes with and without chest compressions.

    PubMed

    Kim, Young-Min; Kim, Ji-Hoon; Kang, Hyung-Goo; Chung, Hyun Soo; Yim, Hyeon-Woo; Jeong, Seung-Hee

    2011-07-01

    The aim of the study was to compare the time taken for intubation (TTI) using the Macintosh and 2 video laryngoscopes (VLs) (GlideScope [GVL]; Saturn Biomedical System, Burnaby, British Columbia, Canada, and Airway Scope [AWS]; Pentax, Tokyo, Japan) with and without chest compressions by experienced intubators in a mannequin model. This was a randomized crossover study. Twenty-two experienced physicians who have limited experience in the VLs participated in the study. The TTI using 3 laryngoscopes with and without compressions were compared. Median TTI difference between 2 conditions was only significant in the AWS (1.64 seconds; P = .01). There were no significant differences in the TTI between the Macintosh and the GVL or the AWS during compressions. In a mannequin model, the Macintosh or the GVL was not affected by chest compressions. The TTI using the AWS was delayed by compressions but not clinically significant. Considering the lack of experience, 2 VLs may be useful adjuncts for intubation by experienced intubators during chest compressions. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. "Push as hard as you can" instruction for telephone cardiopulmonary resuscitation: a randomized simulation study.

    PubMed

    van Tulder, Raphael; Roth, Dominik; Havel, Christof; Eisenburger, Philip; Heidinger, Benedikt; Chwojka, Christof Constantin; Novosad, Heinz; Sterz, Fritz; Herkner, Harald; Schreiber, Wolfgang

    2014-03-01

    The medical priority dispatch system (MPDS®) assists lay rescuers in protocol-driven telephone-assisted cardiopulmonary resuscitation (CPR). Our aim was to clarify which CPR instruction leads to sufficient compression depth. This was an investigator-blinded, randomized, parallel group, simulation study to investigate 10 min of chest compressions after the instruction "push down firmly 5 cm" vs. "push as hard as you can." Primary outcome was defined as compression depth. Secondary outcomes were participants exertion measured by Borg scale, provider's systolic and diastolic blood pressure, and quality values measured by the skill-reporting program of the Resusci(®) Anne Simulator manikin. For the analysis of the primary outcome, we used a linear random intercept model to allow for the repeated measurements with the intervention as a covariate. Thirteen participants were allocated to control and intervention. One participant (intervention) dropped out after min 7 because of exhaustion. Primary outcome showed a mean compression depth of 44.1 mm, with an inter-individual standard deviation (SDb) of 13.0 mm and an intra-individual standard deviation (SDw) of 6.7 mm for the control group vs. 46.1 mm and a SDb of 9.0 mm and SDw of 10.3 mm for the intervention group (difference: 1.9; 95% confidence interval -6.9 to 10.8; p = 0.66). Secondary outcomes showed no difference for exhaustion and CPR-quality values. There is no difference in compression depth, quality of CPR, or physical strain on lay rescuers using the initial instruction "push as hard as you can" vs. the standard MPDS(®) instruction "push down firmly 5 cm." Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Cold aortic flush and chest compressions enable good neurologic outcome after 15 mins of ventricular fibrillation in cardiac arrest in pigs.

    PubMed

    Janata, Andreas; Weihs, Wolfgang; Schratter, Alexandra; Bayegan, Keywan; Holzer, Michael; Frossard, Martin; Sipos, Wolfgang; Springler, Gregor; Schmidt, Peter; Sterz, Fritz; Losert, Udo M; Laggner, Anton N; Kochanek, Patrick M; Behringer, Wilhelm

    2010-08-01

    The induction of deep cerebral hypothermia via ice-cold saline aortic flush during prolonged ventricular fibrillation cardiac arrest, followed by hypothermic stasis and delayed resuscitation (emergency preservation and resuscitation), improved neurologic outcome after cardiac arrest in pigs, as compared to conventional resuscitation. We hypothesized that emergency preservation and resuscitation with chest compressions would further improve outcome in the same model. Prospective experimental study. University research laboratory. : Twenty-four female, large, white breed pigs (27-37 kg). Fifteen minutes of ventricular fibrillation cardiac arrest were followed by 20 mins of resuscitation with chest compressions (control, n = 8), deep cerebral hypothermia via 200 mL/kg 4 degrees C saline aortic flush and hypothermic stasis (emergency preservation and resuscitation, n = 8), and emergency preservation and resuscitation combined with chest compressions (emergency preservation and resuscitation plus chest compressions, n = 8). At 35 mins after cardiac arrest, cardiopulmonary bypass was initiated, followed by defibrillation. Mild hypothermia was continued for 20 hrs. Pigs were evaluated after 9 days using a neurologic deficit (neurologic deficit score: 100% = brain dead; 0%-10% = normal) and an overall performance category score (overall performance category score: 1 = normal; 2 = slightly handicapped; 3 = severely handicapped; 4 = comatose; 5 = dead/brain dead). Brain temperature decreased from 38.5 degrees C to 15.3 degrees C +/- 3.3 degrees C in the emergency preservation and resuscitation group, and to 11.3 degrees C +/- 1.2 degrees C in the emergency preservation and resuscitation plus chest compressions group. In the control group, restoration of spontaneous circulation was achieved in four out of eight pigs, and one survived to 9 days. In the emergency preservation and resuscitation group, restoration of spontaneous circulation was achieved in seven out of eight pigs and five survived; in the emergency preservation and resuscitation plus chest compressions group, all had restoration of spontaneous circulation and seven survived (restoration of spontaneous circulation, p = .08). Neurologic outcome for (median and interquartile range) the control group included overall performance category score of 3, neurologic deficit score of 45%; for the emergency preservation and resuscitation group, overall performance category score was 3 (2-5) and neurologic deficit score was 45% (36; 50) and in the emergency preservation and resuscitation plus chest compressions group, overall performance category score was 2 (1-3) and neurologic deficit score was 13% (5; 21) (overall performance category score, p = .04; neurologic deficit score emergency preservation and resuscitation vs. emergency preservation and resuscitation plus chest compressions, p = .003). Emergency preservation and resuscitation by deep cerebral hypothermia combined with chest compressions during prolonged cardiac arrest in pigs are feasible and improve neurologic outcome.

  12. Cardiopulmonary resuscitation quality and beyond: the need to improve real-time feedback and physiologic monitoring.

    PubMed

    Lin, Steve; Scales, Damon C

    2016-06-28

    High-quality cardiopulmonary resuscitation (CPR) has been shown to improve survival outcomes after cardiac arrest. The current standard in studies evaluating CPR quality is to measure CPR process measures-for example, chest compression rate, depth, and fraction. Published studies evaluating CPR feedback devices have yielded mixed results. Newer approaches that seek to optimize CPR by measuring physiological endpoints during the resuscitation may lead to individualized patient care and improved patient outcomes.

  13. The effect of differing support surfaces on the efficacy of chest compressions using a resuscitation manikin model.

    PubMed

    Tweed, M; Tweed, C; Perkins, G D

    2001-11-01

    External chest compression (ECC) efficacy is influenced by factors including the surface supporting the patient. Air-filled support surfaces are deflated for cardiopulmonary resuscitation, with little evidence to substantiate this. We investigated the effect that differing support surfaces had on ECC efficacy using a CPR manikin model. Four participants carried out four cycles of ECC with an assistant ventilating. The subjects were blinded to the seven support surfaces and the order was randomised. For each participant/surface combination, ECC variables and the participants' perceptions were measured. Participants produced effective ECC with the manikin on the floor (mean proportion correct, 94.5%; mean depth, 42.5 mm). Compared with the floor: the proportion of correct ECC was less for the overlay inflated (P<0.05); the depth of ECC was less effective (30-37 mm) for the overlay inflated/deflated and low-air-loss inflated and foam mattresses (P<0.05). The foam mattress, overlay inflated/deflated, and low-air-loss inflated were perceived as being less stable and as having reduced ECC efficacy compared with the floor. There was no difference or agreement, regarding subjects' perceptions or ECC variables, between the support surfaces or between inflated/deflated air-filled support surfaces. The efficacy of ECC is affected by the support surfaces. There seems little evidence to substantiate deflating all air-filled support surfaces for CPR.

  14. Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest.

    PubMed

    Eichhorn, S; Mendoza, A; Prinzing, A; Stroh, A; Xinghai, L; Polski, M; Heller, M; Lahm, H; Wolf, E; Lange, R; Krane, M

    2017-01-01

    According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR) with an established system (LUCAS II) in a pig model. Methods . Pigs ( n = 5/group) in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO 2 , regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results . Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion . Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device.

  15. Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest

    PubMed Central

    Mendoza, A.; Prinzing, A.; Stroh, A.; Xinghai, L.; Polski, M.; Heller, M.; Lahm, H.; Wolf, E.; Lange, R.; Krane, M.

    2017-01-01

    According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR) with an established system (LUCAS II) in a pig model. Methods. Pigs (n = 5/group) in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO2, regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results. Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion. Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device. PMID:29392137

  16. Performance of cardiopulmonary resuscitation feedback systems in a long-distance train with distributed traction.

    PubMed

    González-Otero, Digna M; de Gauna, Sofía Ruiz; Ruiz, Jesus; Rivero, Raquel; Gutierrez, J J; Saiz, Purificación; Russell, James K

    2018-04-20

    Out-of-hospital cardiac arrest is common in public locations, including public transportation sites. Feedback devices are increasingly being used to improve chest-compression quality. However, their performance during public transportation has not been studied yet. To test two CPR feedback devices representative of the current technologies (accelerometer and electromag- netic-field) in a long-distance train. Volunteers applied compressions on a manikin during the train route using both feedback devices. Depth and rate measurements computed by the devices were compared to the gold-standard values. Sixty-four 4-min records were acquired. The accelerometer-based device provided visual help in all experiments. Median absolute errors in depth and rate were 2.4 mm and 1.3 compressions per minute (cpm) during conventional speed, and 2.5 mm and 1.2 cpm during high speed. The electromagnetic-field-based device never provided CPR feedback; alert messages were shown instead. However, measurements were stored in its internal memory. Absolute errors for depth and rate were 2.6 mm and 0.7 cpm during conventional speed, and 2.6 mm and 0.7 cpm during high speed. Both devices were accurate despite the accelerations and the electromagnetic interferences induced by the train. However, the electromagnetic-field-based device would require modifications to avoid excessive alerts impeding feedback.

  17. Does Video Laryngoscopy Offer Advantages over Direct Laryngoscopy during Cardiopulmonary Resuscitation?

    PubMed

    Saraçoğlu, Ayten; Bezen, Olgaç; Şengül, Türker; Uğur, Egin Hüsnü; Şener, Sibel; Yüzer, Fisun

    2015-08-01

    Interruption of chest compressions should be minimized because of its negative effects on survival. This randomized, controlled, cross-over study aimed to analyze the effectiveness of Macintosh, Miller, McCoy and McGrath laryngoscopes during with or without chest compressions in the scope of a simulated cardiopulmonary resuscitation scenario. The time required for successful tracheal intubation, number of attempts, dental trauma severity and the need for optimization manoeuvres were recorded during cardiopulmonary resuscitation with and without chest compressions. The experience with computer games during the last 10 years were asked to the participants and recorded. McCoy laryngoscope yielded the shortest time for successful tracheal intubation both in the presence of and without chest compressions. During the use of McCoy laryngoscopes, fewer tracheal intubation attempts, lower incidence of dental trauma and lower visual analogue scale scores on the ease of intubation were recorded. Participants who are experienced computer game players using Macintosh, McCoy and McGrath achieved successful tracheal intubation in a significantly shorter time during resuscitation without chest compressions. Dental trauma incidence and number of tracheal intubation attempts did not show any significant difference between the four laryngoscopes being related to the rate of playing computer games. McGrath video laryngoscopes do not appear to have advantages over direct laryngoscopes for securing a smooth and successful tracheal intubation during rhythmic chest compressions. We believe that as McCoy laryngoscope provided tracheal intubation in a shorter time and with fewer attempts, this laryngoscope may increase the success rate of resuscitation.

  18. Comparative Effectiveness of Emergency Resuscitative Thoracotomy versus Closed Chest Compressions among Patients with Critical Blunt Trauma: A Nationwide Cohort Study in Japan.

    PubMed

    Suzuki, Kodai; Inoue, Shigeaki; Morita, Seiji; Watanabe, Nobuo; Shintani, Ayumi; Inokuchi, Sadaki; Ogura, Shinji

    2016-01-01

    Although emergency resuscitative thoracotomy is performed as a salvage maneuver for critical blunt trauma patients, evidence supporting superior effectiveness of emergency resuscitative thoracotomy compared to conventional closed-chest compressions remains insufficient. The objective of this study was to investigate whether emergency resuscitative thoracotomy at the emergency department or in the operating room was associated with favourable outcomes after blunt trauma and to compare its effectiveness with that of closed-chest compressions. This was a retrospective nationwide cohort study. Data were obtained from the Japan Trauma Data Bank for the period between 2004 and 2012. The primary and secondary outcomes were patient survival rates 24 h and 28 d after emergency department arrival. Statistical analyses were performed using multivariable generalized mixed-effects regression analysis. We adjusted for the effects of different hospitals by introducing random intercepts in regression analysis to account for the differential quality of emergency resuscitative thoracotomy at hospitals where patients in cardiac arrest were treated. Sensitivity analyses were performed using propensity score matching. In total, 1,377 consecutive, critical blunt trauma patients who received cardiopulmonary resuscitation in the emergency department or operating room were included in the study. Of these patients, 484 (35.1%) underwent emergency resuscitative thoracotomy and 893 (64.9%) received closed-chest compressions. Compared to closed-chest compressions, emergency resuscitative thoracotomy was associated with lower survival rate 24 h after emergency department arrival (4.5% vs. 17.5%, respectively, P < 0.001) and 28 d after arrival (1.2% vs. 6.0%, respectively, P < 0.001). Multivariable generalized mixed-effects regression analysis with and without a propensity score-matched dataset revealed that the odds ratio for an unfavorable survival rate after 24 h was lower for emergency resuscitative thoracotomy than for closed-chest compressions (P < 0.001). Emergency resuscitative thoracotomy was independently associated with decreased odds of a favorable survival rate compared to closed-chest compressions.

  19. Protocol of a Multicenter International Randomized Controlled Manikin Study on Different Protocols of Cardiopulmonary Resuscitation for laypeople (MANI-CPR)

    PubMed Central

    Contri, Enrico; Burkart, Roman; Borrelli, Paola; Ferraro, Ottavia Eleonora; Tonani, Michela; Cutuli, Amedeo; Bertaia, Daniele; Iozzo, Pasquale; Tinguely, Caroline; Lopez, Daniel; Boldarin, Susi; Deiuri, Claudio; Dénéréaz, Sandrine; Dénéréaz, Yves; Terrapon, Michael; Tami, Christian; Cereda, Cinzia; Somaschini, Alberto; Cornara, Stefano; Cortegiani, Andrea

    2018-01-01

    Introduction Out-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR. Methods and analysis This is a prospective randomised trial performed in eight training centres. Laypeople who passed a basic life support course will be randomised to one of the four CPR protocols in an 8 min simulated cardiac arrest scenario on a manikin: (1) 30 compressions and 2 s pause; (2) 50 compressions and 5 s pause; (3) 100 compressions and 10 s pause; (4) hands-only. The calculated sample size is 552 people. The primary outcome is the percentage of chest compression performed with correct depth evaluated by a computerised feedback system (Laerdal QCPR). Ethics and dissemination Due to the nature of the study, we obtained a waiver from the Ethics Committee (IRCCS Policlinico San Matteo, Pavia, Italy). All participants will sign an informed consent form before randomisation. The results of this study will be published in peer-reviewed journal. The data collected will also be made available in a public data repository. Trial registration number NCT02632500. PMID:29674365

  20. A randomized control hands-on defibrillation study-Barrier use evaluation.

    PubMed

    Wampler, David; Kharod, Chetan; Bolleter, Scotty; Burkett, Alison; Gabehart, Caitlin; Manifold, Craig

    2016-06-01

    Chest compressions and defibrillation are the only therapies proven to increase survival in cardiac arrest. Historically, rescuers must remove hands to shock, thereby interrupting chest compressions. This hands-off time results in a zero blood flow state. Pauses have been associated with poorer neurological recovery. This was a blinded randomized control cadaver study evaluating the detection of defibrillation during manual chest compressions. An active defibrillator was connected to the cadaver in the sternum-apex configuration. The sham defibrillator was not connected to the cadaver. Subjects performed chest compressions using 6 barrier types: barehand, single and double layer nitrile gloves, firefighter gloves, neoprene pad, and a manual chest compression/decompression device. Randomized defibrillations (10 per barrier type) were delivered at 30 joules (J) for bare hand and 360J for all other barriers. After each shock, the subject indicated degree of sensation on a VAS scale. Ten subjects participated. All subjects detected 30j shocks during barehand compressions, with only 1 undetected real shock. All barriers combined totaled 500 shocks delivered. Five (1%) active shocks were detected, 1(0.2%) single layer of Nitrile, 3(0.6%) with double layer nitrile, and 1(0.2%) with the neoprene barrier. One sham shock was reported with the single layer nitrile glove. No shocks were detected with fire gloves or compression decompression device. All shocks detected barely perceptible (0.25(±0.05)cm on 10cm VAS scale). Nitrile gloves and neoprene pad prevent (99%) responder's detection of defibrillation of a cadaver. Fire gloves and compression decompression device prevented detection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Chest compression quality management and return of spontaneous circulation: a matched-pair registry study.

    PubMed

    Lukas, Roman-Patrik; Gräsner, Jan Thorsten; Seewald, Stephan; Lefering, Rolf; Weber, Thomas Peter; Van Aken, Hugo; Fischer, Matthias; Bohn, Andreas

    2012-10-01

    Investigating the effects of any intervention during cardiac arrest remains difficult. The ROSC after cardiac arrest score was introduced to facilitate comparison of rates of return of spontaneous circulation (ROSC) between different ambulance services. To study the influence of chest compression quality management (including training, real-time feedback devices, and debriefing) in comparison with conventional cardiopulmonary resuscitation (CPR), a matched-pair analysis was conducted using data from the German Resuscitation Registry, with the calculated ROSC after cardiac arrest score as the baseline. Matching for independent ROSC after cardiac arrest score variables yielded 319 matched cases from the study period (January 2007-March 2011). The score predicted a 45% ROSC rate for the matched pairs. The observed ROSC increased significantly with chest compression quality management, to 52% (P=0.013; 95% CI, 46-57%). No significant differences were seen in the conventional CPR group (47%; 95% CI, 42-53%). The difference between the observed ROSC rates was not statistically significant. Chest compression quality management leads to significantly higher ROSC rates than those predicted by the prognostic score (ROSC after cardiac arrest score). Matched-pair analysis shows that with conventional CPR, the observed ROSC rate was not significantly different from the predicted rate. Analysis shows a trend toward a higher ROSC rate for chest compression quality management in comparison with conventional CPR. It is unclear whether a single aspect of chest compression quality management or the combination of training, real-time feedback, and debriefing contributed to this result. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Device Assists Cardiac Chest Compression

    NASA Technical Reports Server (NTRS)

    Eichstadt, Frank T.

    1995-01-01

    Portable device facilitates effective and prolonged cardiac resuscitation by chest compression. Developed originally for use in absence of gravitation, also useful in terrestrial environments and situations (confined spaces, water rescue, medical transport) not conducive to standard manual cardiopulmonary resuscitation (CPR) techniques.

  3. Clinical utility of wavelet compression for resolution-enhanced chest radiography

    NASA Astrophysics Data System (ADS)

    Andriole, Katherine P.; Hovanes, Michael E.; Rowberg, Alan H.

    2000-05-01

    This study evaluates the usefulness of wavelet compression for resolution-enhanced storage phosphor chest radiographs in the detection of subtle interstitial disease, pneumothorax and other abnormalities. A wavelet compression technique, MrSIDTM (LizardTech, Inc., Seattle, WA), is implemented which compresses the images from their original 2,000 by 2,000 (2K) matrix size, and then decompresses the image data for display at optimal resolution by matching the spatial frequency characteristics of image objects using a 4,000- square matrix. The 2K-matrix computed radiography (CR) chest images are magnified to a 4K-matrix using wavelet series expansion. The magnified images are compared with the original uncompressed 2K radiographs and with two-times magnification of the original images. Preliminary results show radiologist preference for MrSIDTM wavelet-based magnification over magnification of original data, and suggest that the compressed/decompressed images may provide an enhancement to the original. Data collection for clinical trials of 100 chest radiographs including subtle interstitial abnormalities and/or subtle pneumothoraces and normal cases, are in progress. Three experienced thoracic radiologists will view images side-by- side on calibrated softcopy workstations under controlled viewing conditions, and rank order preference tests will be performed. This technique combines image compression with image enhancement, and suggests that compressed/decompressed images can actually improve the originals.

  4. [Automatic mechanical chest compression during helicopter transportation].

    PubMed

    Kyrval, Helle S; Ahmad, Khalil

    2010-11-15

    We describe a case story with a drowned, hypothermic trauma patient treated with an automatic mechanical chest compression device during helicopter transportation to a trauma center. After falling from a 25 meter high bridge into 2 °C water, she was rescued lifeless 17 minutes later. Advanced life support was initiated. During transport by a rescue helicopter, chest compressions were effectively provided by Lund University Cardiopulmonary Assist System (LUCAS). Upon arrival to a trauma centre approx. 60 minutes later, the patient was treated with extracorporal circulation and rewarmed. She was eventually discharged to her home with minor loss of cerebral function.

  5. Effects of flashlight guidance on chest compression performance in cardiopulmonary resuscitation in a noisy environment.

    PubMed

    You, Je Sung; Chung, Sung Phil; Chang, Chul Ho; Park, Incheol; Lee, Hye Sun; Kim, SeungHo; Lee, Hahn Shick

    2013-08-01

    In real cardiopulmonary resuscitation (CPR), noise can arise from instructional voices and environmental sounds in places such as a battlefield and industrial and high-traffic areas. A feedback device using a flashing light was designed to overcome noise-induced stimulus saturation during CPR. This study was conducted to determine whether 'flashlight' guidance influences CPR performance in a simulated noisy setting. We recruited 30 senior medical students with no previous experience of using flashlight-guided CPR to participate in this prospective, simulation-based, crossover study. The experiment was conducted in a simulated noisy situation using a cardiac arrest model without ventilation. Noise such as patrol car and fire engine sirens was artificially generated. The flashlight guidance device emitted light pulses at the rate of 100 flashes/min. Participants also received instructions to achieve the desired rate of 100 compressions/min. CPR performances were recorded with a Resusci Anne mannequin with a computer skill-reporting system. There were significant differences between the control and flashlight groups in mean compression rate (MCR), MCR/min and visual analogue scale. However, there were no significant differences in correct compression depth, mean compression depth, correct hand position, and correctly released compression. The flashlight group constantly maintained the pace at the desired 100 compressions/min. Furthermore, the flashlight group had a tendency to keep the MCR constant, whereas the control group had a tendency to decrease it after 60 s. Flashlight-guided CPR is particularly advantageous for maintaining a desired MCR during hands-only CPR in noisy environments, where metronome pacing might not be clearly heard.

  6. Safety and Efficacy of Defibrillator Charging During Ongoing Chest Compressions: A Multicenter Study

    PubMed Central

    Edelson, Dana P.; Robertson-Dick, Brian J.; Yuen, Trevor C.; Eilevstjønn, Joar; Walsh, Deborah; Bareis, Charles J.; Vanden Hoek, Terry L.; Abella, Benjamin S.

    2013-01-01

    BACKGROUND Pauses in chest compressions during cardiopulmonary resuscitation have been shown to correlate with poor outcomes. In an attempt to minimize these pauses, the American Heart Association recommends charging the defibrillator during chest compressions. While simulation work suggests decreased pause times using this technique, little is known about its use in clinical practice. METHODS We conducted a multicenter, retrospective study of defibrillator charging at three US academic teaching hospitals between April 2006 and April 2009. Data were abstracted from CPR-sensing defibrillator transcripts. Pre-shock pauses and total hands- off time preceding the defibrillation attempts were compared among techniques. RESULTS A total of 680 charge-cycles from 244 cardiac arrests were analyzed. The defibrillator was charged during ongoing chest compressions in 448 (65.9%) instances with wide variability across the three sites. Charging during compressions correlated with a decrease in median pre-shock pause [2.6 (IQR 1.9–3.8) vs 13.3 (IQR 8.6–19.5) s; p < 0.001] and total hands-off time in the 30 s preceding defibrillation [10.3 (IQR 6.4–13.8) vs 14.8 (IQR 11.0–19.6) s; p < 0.001]. The improvement in hands-off time was most pronounced when rescuers charged the defibrillator in anticipation of the pause, prior to any rhythm analysis. There was no difference in inappropriate shocks when charging during chest compressions (20.0 vs 20.1%; p=0.97) and there was only one instance noted of inadvertent shock administration during compressions, which went unnoticed by the compressor. CONCLUSIONS Charging during compressions is underutilized in clinical practice. The technique is associated with decreased hands-off time preceding defibrillation, with minimal risk to patients or rescuers. PMID:20807672

  7. Easy-to-learn cardiopulmonary resuscitation training programme: a randomised controlled trial on laypeople’s resuscitation performance

    PubMed Central

    Ko, Rachel Jia Min; Lim, Swee Han; Wu, Vivien Xi; Leong, Tak Yam; Liaw, Sok Ying

    2018-01-01

    INTRODUCTION Simplifying the learning of cardiopulmonary resuscitation (CPR) is advocated to improve skill acquisition and retention. A simplified CPR training programme focusing on continuous chest compression, with a simple landmark tracing technique, was introduced to laypeople. The study aimed to examine the effectiveness of the simplified CPR training in improving lay rescuers’ CPR performance as compared to standard CPR. METHODS A total of 85 laypeople (aged 21–60 years) were recruited and randomly assigned to undertake either a two-hour simplified or standard CPR training session. They were tested two months after the training on a simulated cardiac arrest scenario. Participants’ performance on the sequence of CPR steps was observed and evaluated using a validated CPR algorithm checklist. The quality of chest compression and ventilation was assessed from the recording manikins. RESULTS The simplified CPR group performed significantly better on the CPR algorithm when compared to the standard CPR group (p < 0.01). No significant difference was found between the groups in time taken to initiate CPR. However, a significantly higher number of compressions and proportion of adequate compressions was demonstrated by the simplified group than the standard group (p < 0.01). Hands-off time was significantly shorter in the simplified CPR group than in the standard CPR group (p < 0.001). CONCLUSION Simplifying the learning of CPR by focusing on continuous chest compressions, with simple hand placement for chest compression, could lead to better acquisition and retention of CPR algorithms, and better quality of chest compressions than standard CPR. PMID:29167910

  8. Easy-to-learn cardiopulmonary resuscitation training programme: a randomised controlled trial on laypeople's resuscitation performance.

    PubMed

    Ko, Rachel Jia Min; Lim, Swee Han; Wu, Vivien Xi; Leong, Tak Yam; Liaw, Sok Ying

    2018-04-01

    Simplifying the learning of cardiopulmonary resuscitation (CPR) is advocated to improve skill acquisition and retention. A simplified CPR training programme focusing on continuous chest compression, with a simple landmark tracing technique, was introduced to laypeople. The study aimed to examine the effectiveness of the simplified CPR training in improving lay rescuers' CPR performance as compared to standard CPR. A total of 85 laypeople (aged 21-60 years) were recruited and randomly assigned to undertake either a two-hour simplified or standard CPR training session. They were tested two months after the training on a simulated cardiac arrest scenario. Participants' performance on the sequence of CPR steps was observed and evaluated using a validated CPR algorithm checklist. The quality of chest compression and ventilation was assessed from the recording manikins. The simplified CPR group performed significantly better on the CPR algorithm when compared to the standard CPR group (p < 0.01). No significant difference was found between the groups in time taken to initiate CPR. However, a significantly higher number of compressions and proportion of adequate compressions was demonstrated by the simplified group than the standard group (p < 0.01). Hands-off time was significantly shorter in the simplified CPR group than in the standard CPR group (p < 0.001). Simplifying the learning of CPR by focusing on continuous chest compressions, with simple hand placement for chest compression, could lead to better acquisition and retention of CPR algorithms, and better quality of chest compressions than standard CPR. Copyright: © Singapore Medical Association.

  9. The effect of compressor-administered defibrillation on peri-shock pauses in a simulated cardiac arrest scenario.

    PubMed

    Glick, Joshua; Lehman, Erik; Terndrup, Thomas

    2014-03-01

    Coordination of the tasks of performing chest compressions and defibrillation can lead to communication challenges that may prolong time spent off the chest. The purpose of this study was to determine whether defibrillation provided by the provider performing chest compressions led to a decrease in peri-shock pauses as compared to defibrillation administered by a second provider, in a simulated cardiac arrest scenario. This was a randomized, controlled study measuring pauses in chest compressions for defibrillation in a simulated cardiac arrest model. We approached hospital providers with current CPR certification for participation between July, 2011 and October, 2011. Volunteers were randomized to control (facilitator-administered defibrillation) or experimental (compressor-administered defibrillation) groups. All participants completed one minute of chest compressions on a mannequin in a shockable rhythm prior to administration of defibrillation. We measured and compared pauses for defibrillation in both groups. Out of 200 total participants, we analyzed data from 197 defibrillations. Compressor-initiated defibrillation resulted in a significantly lower pre-shock hands-off time (0.57 s; 95% CI: 0.47-0.67) compared to facilitator-initiated defibrillation (1.49 s; 95% CI: 1.35-1.64). Furthermore, compressor-initiated defibrillation resulted in a significantly lower peri-shock hands-off time (2.77 s; 95% CI: 2.58-2.95) compared to facilitator-initiated defibrillation (4.25 s; 95% CI: 4.08-4.43). Assigning the responsibility for shock delivery to the provider performing compressions encourages continuous compressions throughout the charging period and decreases total time spent off the chest. However, as this was a simulation-based study, clinical implementation is necessary to further evaluate these potential benefits.

  10. Trial of Continuous or Interrupted Chest Compressions during CPR.

    PubMed

    Nichol, Graham; Leroux, Brian; Wang, Henry; Callaway, Clifton W; Sopko, George; Weisfeldt, Myron; Stiell, Ian; Morrison, Laurie J; Aufderheide, Tom P; Cheskes, Sheldon; Christenson, Jim; Kudenchuk, Peter; Vaillancourt, Christian; Rea, Thomas D; Idris, Ahamed H; Colella, Riccardo; Isaacs, Marshal; Straight, Ron; Stephens, Shannon; Richardson, Joe; Condle, Joe; Schmicker, Robert H; Egan, Debra; May, Susanne; Ornato, Joseph P

    2015-12-03

    During cardiopulmonary resuscitation (CPR) in patients with out-of-hospital cardiac arrest, the interruption of manual chest compressions for rescue breathing reduces blood flow and possibly survival. We assessed whether outcomes after continuous compressions with positive-pressure ventilation differed from those after compressions that were interrupted for ventilations at a ratio of 30 compressions to two ventilations. This cluster-randomized trial with crossover included 114 emergency medical service (EMS) agencies. Adults with non-trauma-related cardiac arrest who were treated by EMS providers received continuous chest compressions (intervention group) or interrupted chest compressions (control group). The primary outcome was the rate of survival to hospital discharge. Secondary outcomes included the modified Rankin scale score (on a scale from 0 to 6, with a score of ≤3 indicating favorable neurologic function). CPR process was measured to assess compliance. Of 23,711 patients included in the primary analysis, 12,653 were assigned to the intervention group and 11,058 to the control group. A total of 1129 of 12,613 patients with available data (9.0%) in the intervention group and 1072 of 11,035 with available data (9.7%) in the control group survived until discharge (difference, -0.7 percentage points; 95% confidence interval [CI], -1.5 to 0.1; P=0.07); 7.0% of the patients in the intervention group and 7.7% of those in the control group survived with favorable neurologic function at discharge (difference, -0.6 percentage points; 95% CI, -1.4 to 0.1, P=0.09). Hospital-free survival was significantly shorter in the intervention group than in the control group (mean difference, -0.2 days; 95% CI, -0.3 to -0.1; P=0.004). In patients with out-of-hospital cardiac arrest, continuous chest compressions during CPR performed by EMS providers did not result in significantly higher rates of survival or favorable neurologic function than did interrupted chest compressions. (Funded by the National Heart, Lung, and Blood Institute and others; ROC CCC ClinicalTrials.gov number, NCT01372748.).

  11. Development of the probability of return of spontaneous circulation in intervals without chest compressions during out-of-hospital cardiac arrest: an observational study.

    PubMed

    Gundersen, Kenneth; Kvaløy, Jan Terje; Kramer-Johansen, Jo; Steen, Petter Andreas; Eftestøl, Trygve

    2009-02-06

    One of the factors that limits survival from out-of-hospital cardiac arrest is the interruption of chest compressions. During ventricular fibrillation and tachycardia the electrocardiogram reflects the probability of return of spontaneous circulation associated with defibrillation. We have used this in the current study to quantify in detail the effects of interrupting chest compressions. From an electrocardiogram database we identified all intervals without chest compressions that followed an interval with compressions, and where the patients had ventricular fibrillation or tachycardia. By calculating the mean-slope (a predictor of the return of spontaneous circulation) of the electrocardiogram for each 2-second window, and using a linear mixed-effects statistical model, we quantified the decline of mean-slope with time. Further, a mapping from mean-slope to probability of return of spontaneous circulation was obtained from a second dataset and using this we were able to estimate the expected development of the probability of return of spontaneous circulation for cases at different levels. From 911 intervals without chest compressions, 5138 analysis windows were identified. The results show that cases with the probability of return of spontaneous circulation values 0.35, 0.1 and 0.05, 3 seconds into an interval in the mean will have probability of return of spontaneous circulation values 0.26 (0.24-0.29), 0.077 (0.070-0.085) and 0.040(0.036-0.045), respectively, 27 seconds into the interval (95% confidence intervals in parenthesis). During pre-shock pauses in chest compressions mean probability of return of spontaneous circulation decreases in a steady manner for cases at all initial levels. Regardless of initial level there is a relative decrease in the probability of return of spontaneous circulation of about 23% from 3 to 27 seconds into such a pause.

  12. Cardiopulmonary resuscitation update.

    PubMed

    Reynolds, Joshua C; Bond, Michael C; Shaikh, Sanober

    2012-02-01

    Cardiopulmonary resuscitation (CPR) is vital therapy in cardiac arrest care by lay and trained rescuers. Chest compressions are the key component of CPR. Ventilation and airway management should be secondary to high-quality and continuous chest compressions in patients receiving CPR. Only after the patient has had return of spontaneous circulation or completed a cycle of CPR with defibrillation (if appropriate) should attempts at securing an advanced airway be made. Even then, interruptions of chest compressions should be minimized to maintain cardiocerebral perfusion and increase survival. Finally, the ventilation rate should be no more than 8 to 10 breaths per minute. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Clinical assessment of heart chamber size and valve motion during cardiopulmonary resuscitation by two-dimensional echocardiography.

    PubMed

    Rich, S; Wix, H L; Shapiro, E P

    1981-09-01

    It has been generally accepted that enhanced blood flow during closed-chest CPR is generated from compression of the heart between the sternum and the spine. To visualize the heart during closed-chest massage, we performed two-dimensional echocardiography (2DE) during resuscitation efforts in four patients who had cardiac arrest. 2DE analysis showed that (1) the LV internal dimensions did not change appreciably with chest compression; (2) the mitral and aortic valves were open simultaneously during the compression phase; (3) blood flow into the right heart, as evidenced by saline bubble contrast, occurred during the relaxation phase; and (4) compression of the right ventricle and LA occurred in varying amounts in all patients. We conclude that stroke volume from the heart during CPR does not result from compression of the LV. Rather, CPR-induced improved cardiocirculatory dynamics appear to be principally the result of changes in intrathoracic pressure created by sternal compression.

  14. Protocol of a Multicenter International Randomized Controlled Manikin Study on Different Protocols of Cardiopulmonary Resuscitation for laypeople (MANI-CPR).

    PubMed

    Baldi, Enrico; Contri, Enrico; Burkart, Roman; Borrelli, Paola; Ferraro, Ottavia Eleonora; Tonani, Michela; Cutuli, Amedeo; Bertaia, Daniele; Iozzo, Pasquale; Tinguely, Caroline; Lopez, Daniel; Boldarin, Susi; Deiuri, Claudio; Dénéréaz, Sandrine; Dénéréaz, Yves; Terrapon, Michael; Tami, Christian; Cereda, Cinzia; Somaschini, Alberto; Cornara, Stefano; Cortegiani, Andrea

    2018-04-19

    Out-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR. This is a prospective randomised trial performed in eight training centres. Laypeople who passed a basic life support course will be randomised to one of the four CPR protocols in an 8 min simulated cardiac arrest scenario on a manikin: (1) 30 compressions and 2 s pause; (2) 50 compressions and 5 s pause; (3) 100 compressions and 10 s pause; (4) hands-only. The calculated sample size is 552 people. The primary outcome is the percentage of chest compression performed with correct depth evaluated by a computerised feedback system (Laerdal QCPR). ETHICS AND DISSEMINATION: . Due to the nature of the study, we obtained a waiver from the Ethics Committee (IRCCS Policlinico San Matteo, Pavia, Italy). All participants will sign an informed consent form before randomisation. The results of this study will be published in peer-reviewed journal. The data collected will also be made available in a public data repository. NCT02632500. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  16. Retention of cardiopulmonary resuscitation skills after hands-only training versus conventional training in novices: a randomized controlled trial.

    PubMed

    Kim, Young Joon; Cho, Youngsuk; Cho, Gyu Chong; Ji, Hyun Kyung; Han, Song Yi; Lee, Jin Hyuck

    2017-06-01

    Cardiopulmonary resuscitation (CPR) training can improve performance during simulated cardiac arrest; however, retention of skills after training remains uncertain. Recently, hands-only CPR has been shown to be as effective as conventional CPR. The purpose of this study is to compare the retention rate of CPR skills in laypersons after hands-only or conventional CPR training. Participants were randomly assigned to 1 of 2 CPR training methods: 80 minutes of hands-only CPR training or 180 minutes of conventional CPR training. Each participant's CPR skills were evaluated at the end of training and 3 months thereafter using the Resusci Anne manikin with a skill-reporting software. In total, 252 participants completed training; there were 125 in the hands-only CPR group and 127 in the conventional CPR group. After 3 months, 118 participants were randomly selected to complete a post-training test. The hands-only CPR group showed a significant decrease in average compression rate (P=0.015), average compression depth (P=0.031), and proportion of adequate compression depth (P=0.011). In contrast, there was no difference in the skills of the conventional CPR group after 3 months. Conventional CPR training appears to be more effective for the retention of chest compression skills than hands-only CPR training; however, the retention of artificial ventilation skills after conventional CPR training is poor.

  17. Randomised crossover trial of rate feedback and force during chest compressions for paediatric cardiopulmonary resuscitation.

    PubMed

    Gregson, Rachael Kathleen; Cole, Tim James; Skellett, Sophie; Bagkeris, Emmanouil; Welsby, Denise; Peters, Mark John

    2017-05-01

    To determine the effect of visual feedback on rate of chest compressions, secondarily relating the forces used. Randomised crossover trial. Tertiary teaching hospital. Fifty trained hospital staff. A thin sensor-mat placed over the manikin's chest measured rate and force. Rescuers applied compressions to the same paediatric manikin for two sessions. During one session they received visual feedback comparing their real-time rate with published guidelines. Primary: compression rate. Secondary: compression and residual forces. Rate of chest compressions (compressions per minute (compressions per minute; cpm)) varied widely (mean (SD) 111 (13), range 89-168), with a fourfold difference in variation during session 1 between those receiving and not receiving feedback (108 (5) vs 120 (20)). The interaction of session by feedback order was highly significant, indicating that this difference in mean rate between sessions was 14 cpm less (95% CI -22 to -5, p=0.002) in those given feedback first compared with those given it second. Compression force (N) varied widely (mean (SD) 306 (94); range 142-769). Those receiving feedback second (as opposed to first) used significantly lower force (adjusted mean difference -80 (95% CI -128 to -32), p=0.002). Mean residual force (18 N, SD 12, range 0-49) was unaffected by the intervention. While visual feedback restricted excessive compression rates to within the prescribed range, applied force remained widely variable. The forces required may differ with growth, but such variation treating one manikin is alarming. Feedback technologies additionally measuring force (effort) could help to standardise and define effective treatments throughout childhood. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Assessment of low-contrast detectability for compressed digital chest images

    NASA Astrophysics Data System (ADS)

    Cook, Larry T.; Insana, Michael F.; McFadden, Michael A.; Hall, Timothy J.; Cox, Glendon G.

    1994-04-01

    The ability of human observers to detect low-contrast targets in screen-film (SF) images, computed radiographic (CR) images, and compressed CR images was measured using contrast detail (CD) analysis. The results of these studies were used to design a two- alternative forced-choice (2AFC) experiment to investigate the detectability of nodules in adult chest radiographs. CD curves for a common screen-film system were compared with CR images compressed up to 125:1. Data from clinical chest exams were used to define a CD region of clinical interest that sufficiently challenged the observer. From that data, simulated lesions were introduced into 100 normal CR chest films, and forced-choice observer performance studies were performed. CR images were compressed using a full-frame discrete cosine transform (FDCT) technique, where the 2D Fourier space was divided into four areas of different quantization depending on the cumulative power spectrum (energy) of each image. The characteristic curve of the CR images was adjusted so that optical densities matched those of the SF system. The CD curves for SF and uncompressed CR systems were statistically equivalent. The slope of the CD curve for each was - 1.0 as predicted by the Rose model. There was a significant degradation in detection found for CR images compressed to 125:1. Furthermore, contrast-detail analysis demonstrated that many pulmonary nodules encountered in clinical practice are significantly above the average observer threshold for detection. We designed a 2AFC observer study using simulated 1-cm lesions introduced into normal CR chest radiographs. Detectability was reduced for all compressed CR radiographs.

  19. A randomized trial of cardiopulmonary resuscitation training for medical students: voice advisory mannequin compared to guidance provided by an instructor.

    PubMed

    Díez, Nieves; Rodríguez-Díez, María-Cristina; Nagore, David; Fernández, Secundino; Ferrer, Marta; Beunza, Juan-Jose

    2013-08-01

    Current European Resuscitation Guidelines 2010 recommend the use of prompt/feedback devices when training for cardiopulmonary resuscitation (CPR). We aimed to assess the quality of CPR training among second-year medical students with a voice advisory mannequin (VAM) compared to guidance provided by an instructor. Forty-three students received a theoretical reminder about CPR followed by a 2-minute pretest on CPR (compressions/ventilations cycle) with Resusci Anne SkillReporter (Laerdal Medical). They were then randomized into a control group (n = 22), trained by an instructor for 4 minutes per student, and an intervention group (n = 21) trained individually with VAM CPR mannequin for 4 minutes. After training, the students performed a 2-minute posttest, with the same method as the pretest. Participants in the intervention group (VAM) performed more correct hand position (73% vs. 37%; P = 0.014) and tended to display better compression rate (124 min vs. 135 min; P = 0.089). In a stratified analyses by sex we found that only among women trained with VAM was there a significant improvement in compression depth before and after training (36 mm vs. 46 mm, P = 0.018) and in the percentage of insufficient compressions before and after training (56% vs. 15%; P = 0.021). In comparison to the traditional training method involving an instructor, training medical students in CPR with VAM improves the quality of chest compressions in hand position and in compression rate applied to mannequins. Only among women was VAM shown to be superior in compression depth training. This technology reduces costs in 14% in our setup and might potentially release instructors' time for other activities.

  20. Prehospital randomised assessment of a mechanical compression device in out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised trial and economic evaluation.

    PubMed

    Gates, Simon; Lall, Ranjit; Quinn, Tom; Deakin, Charles D; Cooke, Matthew W; Horton, Jessica; Lamb, Sarah E; Slowther, Anne-Marie; Woollard, Malcolm; Carson, Andy; Smyth, Mike; Wilson, Kate; Parcell, Garry; Rosser, Andrew; Whitfield, Richard; Williams, Amanda; Jones, Rebecca; Pocock, Helen; Brock, Nicola; Black, John Jm; Wright, John; Han, Kyee; Shaw, Gary; Blair, Laura; Marti, Joachim; Hulme, Claire; McCabe, Christopher; Nikolova, Silviya; Ferreira, Zenia; Perkins, Gavin D

    2017-03-01

    Mechanical chest compression devices may help to maintain high-quality cardiopulmonary resuscitation (CPR), but little evidence exists for their effectiveness. We evaluated whether or not the introduction of Lund University Cardiopulmonary Assistance System-2 (LUCAS-2; Jolife AB, Lund, Sweden) mechanical CPR into front-line emergency response vehicles would improve survival from out-of-hospital cardiac arrest (OHCA). Evaluation of the LUCAS-2 device as a routine ambulance service treatment for OHCA. Pragmatic, cluster randomised trial including adults with non-traumatic OHCA. Ambulance dispatch staff and those collecting the primary outcome were blind to treatment allocation. Blinding of the ambulance staff who delivered the interventions and reported initial response to treatment was not possible. We also conducted a health economic evaluation and a systematic review of all trials of out-of-hospital mechanical chest compression. Four UK ambulance services (West Midlands, North East England, Wales and South Central), comprising 91 urban and semiurban ambulance stations. Clusters were ambulance service vehicles, which were randomly assigned (approximately 1 : 2) to the LUCAS-2 device or manual CPR. Patients were included if they were in cardiac arrest in the out-of-hospital environment. Exclusions were patients with cardiac arrest as a result of trauma, with known or clinically apparent pregnancy, or aged < 18 years. Patients received LUCAS-2 mechanical chest compression or manual chest compressions according to the first trial vehicle to arrive on scene. Survival at 30 days following cardiac arrest; survival without significant neurological impairment [Cerebral Performance Category (CPC) score of 1 or 2]. We enrolled 4471 eligible patients (1652 assigned to the LUCAS-2 device and 2819 assigned to control) between 15 April 2010 and 10 June 2013. A total of 985 (60%) patients in the LUCAS-2 group received mechanical chest compression and 11 (< 1%) patients in the control group received LUCAS-2. In the intention-to-treat analysis, 30-day survival was similar in the LUCAS-2 (104/1652, 6.3%) and manual CPR groups [193/2819, 6.8%; adjusted odds ratio (OR) 0.86, 95% confidence interval (CI) 0.64 to 1.15]. Survival with a CPC score of 1 or 2 may have been worse in the LUCAS-2 group (adjusted OR 0.72, 95% CI 0.52 to 0.99). No serious adverse events were noted. The systematic review found no evidence of a survival advantage if mechanical chest compression was used. The health economic analysis showed that LUCAS-2 was dominated by manual chest compression. There was substantial non-compliance in the LUCAS-2 arm. For 272 out of 1652 patients (16.5%), mechanical chest compression was not used for reasons that would not occur in clinical practice. We addressed this issue by using complier average causal effect analyses. We attempted to measure CPR quality during the resuscitation attempts of trial participants, but were unable to do so. There was no evidence of improvement in 30-day survival with LUCAS-2 compared with manual compressions. Our systematic review of recent randomised trials did not suggest that survival or survival without significant disability may be improved by the use of mechanical chest compression. The use of mechanical chest compression for in-hospital cardiac arrest, and in specific circumstances (e.g. transport), has not yet been evaluated. Current Controlled Trials ISRCTN08233942. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 21, No. 11. See the NIHR Journals Library website for further project information.

  1. Smartwatch feedback device for high-quality chest compressions by a single rescuer during infant cardiac arrest: a randomized, controlled simulation study.

    PubMed

    Lee, Juncheol; Song, Yeongtak; Oh, Jaehoon; Chee, Youngjoon; Ahn, Chiwon; Shin, Hyungoo; Kang, Hyunggoo; Lim, Tae Ho

    2018-02-12

    According to the guidelines, rescuers should provide chest compressions (CC) ∼1.5 inches (40 mm) for infants. Feedback devices could help rescuers perform CC with adequate rates (CCR) and depths (CCD). However, there is no CC feedback device for infant cardiopulmonary resuscitation (CPR). We suggest a smartwatch-based CC feedback application for infant CPR. We created a smartwatch-based CC feedback application. This application provides feedback on CCD and CCR by colour and text for infant CPR. To evaluate the application, 30 participants were divided randomly into two groups on the basis of whether CC was performed with or without the assistance of the smartwatch application. Both groups performed continuous CC-only CPR for 2 min on an infant mannequin placed on a firm table. We collected CC parameters from the mannequin, including the proportion of correct depth, CCR, CCD and the proportion of correct decompression depth. Demographics between the two groups were not significantly different. The median (interquartile range) proportion of correct depth was 99 (97-100) with feedback compared with 83 (58-97) without feedback (P=0.002). The CCR and proportion of correct decompression depth were not significantly different between the two groups (P=0.482 and 0.089). The CCD of the feedback group was significantly deeper than that of the control group [feedback vs. 41.2 (39.8-41.7) mm vs. 38.6 (36.1-39.6) mm; P=0.004]. Rescuers who receive feedback of CC parameters from a smartwatch could perform adequate CC during infant CPR.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.

  2. Mask leak increases and minute ventilation decreases when chest compressions are added to bag ventilation in a neonatal manikin model.

    PubMed

    Tracy, Mark B; Shah, Dharmesh; Hinder, Murray; Klimek, Jan; Marceau, James; Wright, Audrey

    2014-05-01

    To determine changes in respiratory mechanics when chest compressions are added to mask ventilation, as recommended by the International Liaison Committee on Resuscitation (ILCOR) guidelines for newborn infants. Using a Laerdal Advanced Life Support leak-free baby manikin and a 240-mL self-inflating bag, 58 neonatal staff members were randomly paired to provide mask ventilation, followed by mask ventilation with chest compressions with a 1:3 ratio, for two minutes each. A Florian respiratory function monitor was used to measure respiratory mechanics, including mask leak. The addition of chest compressions to mask ventilation led to a significant reduction in inflation rate, from 63.9 to 32.9 breaths per minute (p < 0.0001), mean airway pressure reduced from 7.6 to 4.9 cm H2 O (p < 0.001), minute ventilation reduced from 770 to 451 mL/kg/min (p < 0.0001), and there was a significant increase in paired mask leak of 6.8% (p < 0.0001). Adding chest compressions to mask ventilation, in accordance with the ILCOR guidelines, in a manikin model is associated with a significant reduction in delivered ventilation and increase in mask leak. If similar findings occur in human infants needing an escalation in resuscitation, there is a potential risk of either delay in recovery or inadequate response to resuscitation. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  3. Using Simulation as an Investigational Methodology to Explore the Impact of Technology on Team Communication and Patient Management: A Pilot Evaluation of the Effect of an Automated Compression Device.

    PubMed

    Gittinger, Matthew; Brolliar, Sarah M; Grand, James A; Nichol, Graham; Fernandez, Rosemarie

    2017-06-01

    This pilot study used a simulation-based platform to evaluate the effect of an automated mechanical chest compression device on team communication and patient management. Four-member emergency department interprofessional teams were randomly assigned to perform manual chest compressions (control, n = 6) or automated chest compressions (intervention, n = 6) during a simulated cardiac arrest with 2 phases: phase 1 baseline (ventricular tachycardia), followed by phase 2 (ventricular fibrillation). Patient management was coded using an Advanced Cardiovascular Life Support-based checklist. Team communication was categorized in the following 4 areas: (1) teamwork focus; (2) huddle events, defined as statements focused on re-establishing situation awareness, reinforcing existing plans, and assessing the need to adjust the plan; (3) clinical focus; and (4) profession of team member. Statements were aggregated for each team. At baseline, groups were similar with respect to total communication statements and patient management. During cardiac arrest, the total number of communication statements was greater in teams performing manual compressions (median, 152.3; interquartile range [IQR], 127.6-181.0) as compared with teams using an automated compression device (median, 105; IQR, 99.5-123.9). Huddle events were more frequent in teams performing automated chest compressions (median, 4.0; IQR, 3.1-4.3 vs. 2.0; IQR, 1.4-2.6). Teams randomized to the automated compression intervention had a delay to initial defibrillation (median, 208.3 seconds; IQR, 153.3-222.1 seconds) as compared with control teams (median, 63.2 seconds; IQR, 30.1-397.2 seconds). Use of an automated compression device may impact both team communication and patient management. Simulation-based assessments offer important insights into the effect of technology on healthcare teams.

  4. Comparison of intubation modalities in a simulated cardiac arrest with uninterrupted chest compressions.

    PubMed

    Tandon, Navin; McCarthy, Matthew; Forehand, Brett; Carlson, Jestin N

    2014-10-01

    Interruptions in chest compressions during cardiopulmonary resuscitation can negatively impact survival. Several new endotracheal intubation (ETI) techniques including video laryngoscopy may allow for ETI with minimal or no interruptions in chest compressions. We sought to determine the impact of three different ETI techniques upon time to intubation (TTI) in a simulated cardiac arrest during uninterrupted chest compression. We performed a randomised crossover study with a convenience sample of emergency physicians using three different ETI techniques: direct laryngoscopy (DL), GlideScope video laryngoscopy (GVL) and GlideScope video laryngoscopy with bougie (GVL-B). Providers performed ETI on a manikin on a hospital bed with concurrent chest compressions. Our primary outcome, TTI, was defined as the time from insertion of the laryngoscope blade until first breath. Given the correlated nature of the data, we used the paired t test to assess the differences in mean TTIs between GVL minus DL and GVL-B minus DL. We also ran the analysis stratified by provider experience. We enrolled 20 providers with a median TTI (IQR) by device of: DL 27 s (20.3, 35.4), GVL 20.6 s (17.7, 27.1) and GVL-B 60.1 s (39.1, 99). The mean GVL-DL difference was -10.1 s (-17.9-2.3) while the mean GVL-B-DL difference was 45.6 s (19.8-71.4) (p<0.001). The GVL-B required the greatest TTI across providers of varying experience levels. In this simulated model of cardiac arrest with uninterrupted chest compressions, TTI was shorter for GVL than DL while use of the GVL with bougie resulted in longer TTI. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Should unobstructed gasping be facilitated and confirmed before administering adrenaline, otherwise, give titrated vasopressin?

    PubMed

    Rottenberg, Eric M

    2015-02-01

    A recent commentary, "Resuscitation That's (Un)Shockable: Time to Get the Adrenaline Flowing", published in the New England Journal of Medicine Journal Watch called attention to a relatively recent study showing that a large and increasing percentage of patients with in-hospital cardiac arrests exhibit initial nonshockable rhythms (asystole or pulseless electrical activity [PEA]; 82% in 2009 vs 69% in 2000) and a most recent study that concluded that neurologically intact survival to hospital discharge after in-hospital cardiac arrest was significantly more likely after earlier epinephrine administration. It was found that delayed administration of epinephrine was associated significantly with lower chance for survival to hospital discharge, in stepwise fashion (12%, 10%, 8%, and 7% survival, respectively, for patients receiving their first epinephrine dose≤3, 4-6, 7-9, and >9 minutes after arrest). Although early use of epinephrine to manage patients with nonshockable rhythms lacks strong evidence to support efficacy, focus on time to epinephrine administration-in addition to high-quality chest compressions-might be the best early intervention. However, evidence may strongly support the recommendation that adrenaline needs to be used very early because without effective-depth cardiopulmonary resuscitation (CPR) with complete recoil, epinephrine may only be effective when gasping is present, which is a time-limited phenomenon. However, because very few rescuers can perform effective-depth chest compressions with complete recoil, gasping is critically necessary for adequate ventilation and generation of adequate coronary and cerebral perfusion. However, under acidemic conditions and high catecholamine levels and/or absence of gasping, vasopressin should be administered instead. Published by Elsevier Inc.

  6. [Protective effect of erythropoietin on brain tissue in rats with cardiopulmonary resuscitation after asphyxia].

    PubMed

    Chunling, Ji; Hourong, Zhou; Xiulin, Yang; Qian, Zhang; Yuhui, Yuan; Jia, Huang

    2015-12-01

    To study the protective effect of erythropoietin (EPO) on brain tissue with cardiac arrest-cardiopulmonary resuscitation (CA-CPR) and its mechanism. 120 male Sprague-Dawley (SD) rats were randomly divided into three groups (each n = 40), namely: sham group, routine chest compression group, and conventional chest compression + EPO group (EPO group). The rats in each group were subdivided into CA and 6, 12, 24, 48 hours after restoration of spontaneous circulation (ROSC) five subgroups (each n = 8). The model of CA was reproduced according to the Hendrickx classical asphyxia method followed by routine chest compression, and the rats in sham group only underwent anesthesia, tracheostomy intubation and venous-puncture without asphyxia and CPR. The rats in EPO group were given the routine chest compression + EPO 5 kU/kg (2 mL/kg) after CA. Blood sample was collected at different time points of intervention for the determination the content of serum S100 β protein by enzyme linked immunosorbent assay (ELISA). All the rats were sacrificed at the corresponding time points, and the hippocampus was harvested for the calculation of the number of S100 β protein positive cells, and to examine the pathological changes and their scores at 24 hours after ROSC by light microscopy. With prolongation of ROSC time, the serum levels of S100 β protein (µg/L) in the routine chose compression group and the EPO group were significantly elevated, peaking at 24 hours (compared with CA: 305.7 ± 29.2 vs. 44.4 ± 6.2 in routine chest compression group, and 276.7 ± 28.9 vs. 44.7 ± 5.6 in the EPO group, both P < 0.05), followed by a fall. The levels of S100 β protein at each time point after ROSC in EPO group were significanthy lower than those of the routine chest compression group (83.2 ± 7.5 vs. 114.3 ± 15.3 at 6 hours, 123.9 ± 20.2 vs. 184.9 ± 22.2 at 12 hours, 276.7 ± 28.9 vs. 305.7 ± 29.2 at 24 hours, 256.3 ± 26.6 vs. 283.2 ± 23.6 at 48 hours, all P < 0.05). With the prolongation of ROSC time, the S100 β protein positive cell number in brain (cells/HP) in the routine chest compression group and the EPO group was significantly increased, peaking at 24 hours (compared with CA: 14.3 ± 2.2 vs. 6.7 ± 0.7 in the routine chest compression group, 11.3 ± 1.3 vs. 6.8 ± 0.9 in the EPO group, both P < 0.05), then it began to fall. The S100 β protein positive cell number in brain at each time point after ROSC in the EPO group was significantly lower than that of the routine chest compression group (7.0 ± 0.9 vs. 7.9 ± 1.9 at 6 hours, 8.4 ± 1.1 vs. 10.2 ± 2.2 at 12 hours, 11.3 ± 1.3 vs. 14.3 ± 2.2 at 24 hours, 8.3 ± 0.8 vs. 10.8 ± 2.0 at 48 hours, all P < 0.05). Under the light microscope, a serious brain cortex injury was found after reproduction of the model, and the degree of injury was reduced after EPO intervention. The pathological score at 24 hours after ROSC in EPO group was lower than that of routine chest compression group (3.83 ± 0.73 vs. 4.17 ± 0.75, P < 0.05). The S100 β protein level in serum and brain tissue was increased early in asphyxia CA-CPR rats. EPO intervention can reduce the expression of S100 protein and reduce the degree of brain injury.

  7. Breath-Hold Diving.

    PubMed

    Fitz-Clarke, John R

    2018-03-25

    Breath-hold diving is practiced by recreational divers, seafood divers, military divers, and competitive athletes. It involves highly integrated physiology and extreme responses. This article reviews human breath-hold diving physiology beginning with an historical overview followed by a summary of foundational research and a survey of some contemporary issues. Immersion and cardiovascular adjustments promote a blood shift into the heart and chest vasculature. Autonomic responses include diving bradycardia, peripheral vasoconstriction, and splenic contraction, which help conserve oxygen. Competitive divers use a technique of lung hyperinflation that raises initial volume and airway pressure to facilitate longer apnea times and greater depths. Gas compression at depth leads to sequential alveolar collapse. Airway pressure decreases with depth and becomes negative relative to ambient due to limited chest compliance at low lung volumes, raising the risk of pulmonary injury called "squeeze," characterized by postdive coughing, wheezing, and hemoptysis. Hypoxia and hypercapnia influence the terminal breakpoint beyond which voluntary apnea cannot be sustained. Ascent blackout due to hypoxia is a danger during long breath-holds, and has become common amongst high-level competitors who can suppress their urge to breathe. Decompression sickness due to nitrogen accumulation causing bubble formation can occur after multiple repetitive dives, or after single deep dives during depth record attempts. Humans experience responses similar to those seen in diving mammals, but to a lesser degree. The deepest sled-assisted breath-hold dive was to 214 m. Factors that might determine ultimate human depth capabilities are discussed. © 2018 American Physiological Society. Compr Physiol 8:585-630, 2018. Copyright © 2018 American Physiological Society. All rights reserved.

  8. Deep-seated intramuscular lipoma penetrates the intercostal muscle

    PubMed Central

    Hwang, Jinwook; Min, Byoung-Ju; Shin, Jae Seung

    2015-01-01

    Deep-seated intramuscular lipomas are rare, and most exhibit an infiltrating behavior. This study reports serial radiographs of a lipoma in chest wall muscles which penetrated the intercostal muscle for a 6-year period. Although this lipoma did not involve the parietal pleura, it compressed lung. To the authors’ knowledge, the present study is the first report to show the growth of a deep-seated chest wall lipoma into the thoracic cavity through serial radiographs. We consider the surgical treatment is needed before deep-seated intramuscular chest wall lipoma compress intrathoracic structures. PMID:26623127

  9. Transthoracic impedance used to evaluate performance of cardiopulmonary resuscitation during out of hospital cardiac arrest.

    PubMed

    Stecher, Frederik S; Olsen, Jan-Aage; Stickney, Ronald E; Wik, Lars

    2008-12-01

    There is a need to measure cardiopulmonary resuscitation (CPR) in order to document whether ambulance personnel follow CPR guidelines. Our goal was to do this using defibrillator technology based on changes in transthoracic impedance (TTI) produced by chest compressions and ventilations. 122 incidents of out-of-hospital cardiac arrest between May 2003 and February 2004 were analysed based on data recorded from defibrillators in Oslo EMS. New software was used to analyze chest compressions and ventilations based on changes in thoracic impedance between the defibrillator pads, as well as ECG and other event data. In total, 25+/-14% (varying from 76% to 3%) of the time chest compressions were not performed on patients without spontaneous circulation (NFR=No Flow Ratio). When adjusting for time spent on analysis of ECG, pulse check and defibrillation, NFR was 20+/-13% (varying from 70% to 3%). Mean compressions delivered per minute was 87+/-16 and the compression rate during active compressions was 117+/-9min(-1). Individual variation was 31-117min(-1) (mean) and 95-144min(-1) (active periods). A mean of 14+/-3ventilations/min was recorded, varying from 8 to 26min(-1). Compared with the rest of the episode, the first 5min had a significantly higher proportion of time without chest compressions; 30+/-17% (p<0.001) and significantly lower mean compression and ventilation rates; 80+/-19min(-1) and 12+/-4min(-1), respectively (p<0.001 in both cases). Core CPR values can be measured from TTI signals by using a standard defibrillator and new software. NFR was 25% (20% adjusted) with great rescuer variability.

  10. Simulation exercise to improve retention of cardiopulmonary resuscitation priorities for in-hospital cardiac arrests: A randomized controlled trial.

    PubMed

    Sullivan, Nancy J; Duval-Arnould, Jordan; Twilley, Marida; Smith, Sarah P; Aksamit, Deborah; Boone-Guercio, Pam; Jeffries, Pamela R; Hunt, Elizabeth A

    2015-01-01

    Traditional American Heart Association (AHA) cardiopulmonary resuscitation (CPR) curriculum focuses on teams of two performing quality chest compressions with rescuers on their knees but does not include training specific to In-Hospital Cardiac Arrests (IHCA), i.e. patient in hospital bed with large resuscitation teams and sophisticated technology available. A randomized controlled trial was conducted with the primary goal of evaluating the effectiveness and ideal frequency of in-situ training on time elapsed from call for help to; (1) initiation of chest compressions and (2) successful defibrillation in IHCA. Non-intensive care unit nurses were randomized into four groups: standard AHA training (C) and three groups that participated in 15 min in-situ IHCA training sessions every two (2M), three (3M) or six months (6M). Curriculum included specific choreography for teams to achieve immediate chest compressions, high chest compression fractions and rapid defibrillation while incorporating use of a backboard, stepstool. More frequent training was associated with decreased median (IQR) seconds to: starting compressions: [C: 33(25-40) vs. 6M: 21(15-26) vs. 3M: 14(10-20) vs. 2M: 13(9-20); p < 0.001]; and defibrillation: [C: 157(140-254) vs. 6M: 138(107-158) vs. 3M: 115(101-119) vs. 2M: 109(98-129); p < 0.001]. A composite outcome of key priorities, compressions within 20s, defibrillation within 180 s and use of a backboard, revealed improvement with more frequent training sessions: [C:5%(1/18) vs. 6M: 23%(4/17) vs. 3M: 56%(9/16) vs. 2M: 73%(11/15); p < 0.001]. Results revealed short in-situ training sessions conducted every 3 months are effective in improving timely initiation of chest compressions and defibrillation in IHCA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. Cardiorespiratory interactions and blood flow generation during cardiac arrest and other states of low blood flow.

    PubMed

    Sigurdsson, Gardar; Yannopoulos, Demetris; McKnite, Scott H; Lurie, Keith G

    2003-06-01

    Recent advances in cardiopulmonary resuscitation have shed light on the importance of cardiorespiratory interactions during shock and cardiac arrest. This review focuses on recently published studies that evaluate factors that determine preload during chest compression, methods that can augment preload, and the detrimental effects of hyperventilation and interrupting chest compressions. Refilling of the ventricles, so-called ventricular preload, is diminished during cardiovascular collapse and resuscitation from cardiac arrest. In light of the potential detrimental effects and challenges of large-volume fluid resuscitations, other methods have increasing importance. During cardiac arrest, active decompression of the chest and impedance of inspiratory airflow during the recoil of the chest work by increasing negative intrathoracic pressure and, hence, increase refilling of the ventricles and increase cardiac preload, with improvement in survival. Conversely, increased frequency of ventilation has detrimental effects on coronary perfusion pressure and survival rates in cardiac arrest and severe shock. Prolonged interruption of chest compressions for delivering single-rescuer ventilation or analyzing rhythm before shock delivery is associated with decreased survival rate. Cardiorespiratory interactions are of profound importance in states of cardiovascular collapse in which increased negative intrathoracic pressure during decompression of the chest has a favorable effect and increased intrathoracic pressure with ventilation has a detrimental effect on survival rate.

  12. A novel protocol for dispatcher assisted CPR improves CPR quality and motivation among rescuers-A randomized controlled simulation study.

    PubMed

    Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo

    2017-01-01

    Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. The impact of airway management on quality of cardiopulmonary resuscitation: an observational study in patients during cardiac arrest.

    PubMed

    Yeung, Joyce; Chilwan, Mehboob; Field, Richard; Davies, Robin; Gao, Fang; Perkins, Gavin D

    2014-07-01

    Minimising interruptions in chest compressions is associated with improved survival from cardiac arrest. Current in-hospital guidelines recommend continuous chest compressions after the airway is secured on the premise that this will reduce no flow time. The aim of this study was to determine the effect of advanced airway use on the no flow ratio and other measures of CPR quality. Consecutive adult patients who sustained an in-hospital cardiac arrest were enrolled in this prospective observational study. The quality of CPR was measured using the Q-CPR device (Phillips, UK) before and after an advanced airway device (endotracheal tube [ET] or laryngeal mask airway [LMA]) was inserted. Patients receiving only bag-mask ventilation were used as the control cohort. The primary outcome was no flow ratio (NFR). Secondary outcomes were chest compression rate, depth, compressions too shallow, compressions with leaning, ventilation rate, inflation time, change in impedance and time required to successfully insert airway device. One hundred patients were enrolled in the study (2008-2011). Endotracheal tube and LMA placement took similar durations (median 15.8 s (IQR 6.8-19.4) vs. LMA median 8.0s (IQR 5.5-15.9), p=0.1). The use of an advanced airway was associated with improved no flow ratios (endotracheal tube placement (n=50) improved NFR from baseline median 0.24 IQR 0.17-0.40) to 0.15 to (IQR 0.09-0.28), p=0.012; LMA (n=25) from median 0.28 (IQR 0.23-0.40) to 0.13 (IQR 0.11- 0.19), p=0.0001). There was no change in NFR in patients managed solely with bag valve mask (BVM) (n=25) (median 0.29 (IQR 0.18-0.59) vs. median 0.26 (IQR 0.12-0.37), p=0.888). There was no significant difference in time taken to successfully insert the airway device between the two groups. The use of an advanced airway (ETT or LMA) during in-hospital cardiac arrest was associated with improved no flow ratio. Further studies are required to determine the effect of airway devices on overall patient outcomes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Retention of cardiopulmonary resuscitation skills after hands-only training versus conventional training in novices: a randomized controlled trial

    PubMed Central

    Kim, Young Joon; Cho, Youngsuk; Cho, Gyu Chong; Ji, Hyun Kyung; Han, Song Yi; Lee, Jin Hyuck

    2017-01-01

    Objective Cardiopulmonary resuscitation (CPR) training can improve performance during simulated cardiac arrest; however, retention of skills after training remains uncertain. Recently, hands-only CPR has been shown to be as effective as conventional CPR. The purpose of this study is to compare the retention rate of CPR skills in laypersons after hands-only or conventional CPR training. Methods Participants were randomly assigned to 1 of 2 CPR training methods: 80 minutes of hands-only CPR training or 180 minutes of conventional CPR training. Each participant’s CPR skills were evaluated at the end of training and 3 months thereafter using the Resusci Anne manikin with a skill-reporting software. Results In total, 252 participants completed training; there were 125 in the hands-only CPR group and 127 in the conventional CPR group. After 3 months, 118 participants were randomly selected to complete a post-training test. The hands-only CPR group showed a significant decrease in average compression rate (P=0.015), average compression depth (P=0.031), and proportion of adequate compression depth (P=0.011). In contrast, there was no difference in the skills of the conventional CPR group after 3 months. Conclusion Conventional CPR training appears to be more effective for the retention of chest compression skills than hands-only CPR training; however, the retention of artificial ventilation skills after conventional CPR training is poor. PMID:28717778

  15. The Effect of the Duration of Basic Life Support Training on the Learners' Cardiopulmonary and Automated External Defibrillator Skills

    PubMed Central

    Kang, Ku Hyun; Song, Keun Jeong; Lee, Chang Hee

    2016-01-01

    Background. Basic life support (BLS) training with hands-on practice can improve performance during simulated cardiac arrest, although the optimal duration for BLS training is unknown. This study aimed to assess the effectiveness of various BLS training durations for acquiring cardiopulmonary resuscitation (CPR) and automated external defibrillator (AED) skills. Methods. We randomised 485 South Korean nonmedical college students into four levels of BLS training: level 1 (40 min), level 2 (80 min), level 3 (120 min), and level 4 (180 min). Before and after each level, the participants completed questionnaires regarding their willingness to perform CPR and use AEDs, and their psychomotor skills for CPR and AED use were assessed using a manikin with Skill-Reporter™ software. Results. There were no significant differences between levels 1 and 2, although levels 3 and 4 exhibited significant differences in the proportion of overall adequate chest compressions (p < 0.001) and average chest compression depth (p = 0.003). All levels exhibited a greater posttest willingness to perform CPR and use AEDs (all, p < 0.001). Conclusions. Brief BLS training provided a moderate level of skill for performing CPR and using AEDs. However, high-quality skills for CPR required longer and hands-on training, particularly hands-on training with AEDs. PMID:27529066

  16. Comparison of blind intubation through the I-gel and ILMA Fastrach by nurses during cardiopulmonary resuscitation: a manikin study.

    PubMed

    Melissopoulou, Theodora; Stroumpoulis, Konstantinos; Sampanis, Michail A; Vrachnis, Nikolaos; Papadopoulos, Georgios; Chalkias, Athanasios; Xanthos, Theodoros

    2014-01-01

    To investigate whether nursing staff can successfully use the I-gel and the intubating laryngeal mask Fastrach (ILMA) during cardiopulmonary resuscitation. Although tracheal intubation is considered to be the optimal method for securing the airway during cardiopulmonary resuscitation, laryngoscopy requires a high level of skill. Forty five nurses inserted the I-gel and the ILMA in a manikin, with continuous and without chest compressions. Mean intubation times for the ILMA and I-gel without chest compressions were 20.60 ± 3.27 and 18.40 ± 3.26 s, respectively (p < 0.0005). ILMA proved more successful than the I-gel regardless of compressions. Continuation of compressions caused a prolongation in intubation times for both the I-gel (p < 0.0005) and the ILMA (p < 0.0005). In this mannequin study, nursing staff can successfully intubate using the I-gel and the ILMA as conduits with comparable success rates, regardless of whether chest compressions are interrupted or not. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Compression asphyxia in upright suspended position.

    PubMed

    Tumram, Nilesh Keshav; Ambade, Vipul Namdeorao; Dixit, Pradeep Gangadhar

    2014-06-01

    In compression asphyxia, the respiration is prevented by external pressure on the body. It is usually due to external force compressing the trunk due to heavy weight over chest/abdomen and is associated with internal injuries. In the present case, the victim was suspended in an upright position owing to wedging of the chest and the abdomen in the gap between 2 parallel bridges undergoing construction. There was neither any heavy weight over the body, nor was any external force applied over the trunk. Moreover, there was neither any severe blunt force injury nor any significant pathological natural disease contributing to the cause of death. The body was wedged in the gap between 2 static hard surfaces. The victim was unable to extricate himself from the position owing to impairment of cognitive responses and coordination due to influence of alcohol. The victim died as a result of "static" asphyxia due to compression of the chest and the abdomen. Compression asphyxia in upright suspended position under this circumstance is very rare and not reported previously to the best of our knowledge.

  18. Influence of water depth on energy expenditure during aquatic walking in people post stroke.

    PubMed

    Lim, Hyosok; Azurdia, Daniel; Jeng, Brenda; Jung, Taeyou

    2018-05-11

    This study aimed to investigate the metabolic cost during aquatic walking at various depths in people post stroke. The secondary purpose was to examine the differences in metabolic cost between aquatic walking and land walking among individuals post stroke. A cross-sectional research design is used. Twelve participants post stroke (aged 55.5 ± 13.3 years) completed 6 min of walking in 4 different conditions: chest-depth, waist-depth, and thigh-depth water, and land. Data were collected on 4 separate visits with at least 48 hr in between. On the first visit, all participants were asked to walk in chest-depth water at their fastest speed. The walking speed was used as a reference speed, which was applied to the remaining 3 walking conditions. The order of remaining walking conditions was randomized. Energy expenditure (EE), oxygen consumption (VO 2 ), and minute ventilation (V E ) were measured with a telemetric metabolic system. Our findings showed statistically significant differences in EE, VO 2 , and V E among the 4 different walking conditions: chest-depth, waist-depth, and thigh-depth water, and land (all p < .05). The participants demonstrated reduction in all variables as the water depth increased from thigh depth to chest depth. Significantly higher values in EE and VO 2 were found when the water depth increased from waist depth to chest depth. However, no significant difference was found in all variables between thigh-depth and waist-depth walking. Only thigh-depth walking revealed significant differences when compared with land walking in all variables. People post stroke consume less energy in chest-depth water, which may allow them to perform prolonged duration of training. Thigh-depth water demonstrated greater EE compared with other water depths; thus, it can be recommended for time-efficient cardiovascular exercise. Waist-depth water showed similar EE to land walking, which may have been contributed by the countervailing effects of buoyancy and water resistance. Copyright © 2018 John Wiley & Sons, Ltd.

  19. Dispatcher-assisted compression-only cardiopulmonary resuscitation provides best quality cardiopulmonary resuscitation by laypersons: A randomised controlled single-blinded manikin trial.

    PubMed

    Spelten, Oliver; Warnecke, Tobias; Wetsch, Wolfgang A; Schier, Robert; Böttiger, Bernd W; Hinkelbein, Jochen

    2016-08-01

    High-quality cardiopulmonary resuscitation (CPR) by laypersons is a key determinant of both outcome and survival for out-of-hospital cardiac arrest. Dispatcher-assisted CPR (telephone-CPR, T-CPR) increases the frequency and correctness of bystander-CPR but results in prolonged time to first chest compressions. However, it remains unclear whether instructions for rescue ventilation and/or chest compressions should be recommended for dispatcher-assisted CPR. The aim of this study was to evaluate both principles of T-CPR with respect to CPR quality. Randomised controlled single-blinded manikin trial. University Hospital of Cologne, Germany, 1 July 2012 to 30 September 2012. Sixty laypersons between 18 and 65 years. Medically educated individuals, medical professionals and pregnant women were excluded. Participants were asked to resuscitate a manikin and were randomised into three groups: not dispatcher-assisted (uninstructed) CPR (group 1; U-CPR; n = 20), dispatcher-assisted compression-only CPR (group 2; DACO-CPR; n = 19) and full dispatcher-assisted CPR with rescue ventilation (group 3; DAF-CPR; n = 19). Specific parameters of CPR quality [i.e. no-flow-time (NFT) as well as compression and ventilation parameters] were analysed. To compare different groups we used Student's t test and P less than 0.05 was considered significant. Initial NFT was lowest in the DACO-CPR group (mean 21.3 ± 14.4%), followed by dispatcher-assisted full CPR (mean 49.1 ± 8.5%) and by unassisted CPR (mean 55.0 ± 12.9%). Initial NFT covering the time of instruction was lower in DACO-CPR (12.1 ± 5.4%) as compared to dispatcher-assisted full CPR (20.7 ± 8.1%). Compression depth was similar in all three groups: 40.6 ± 13.0 mm (unassisted CPR), 41.0 ± 12.2 mm (DACO-CPR) and 38.8 ± 15.8 mm (dispatcher-assisted full CPR). Average compression frequency was highest in the DACO-CPR group (65.2 ± 22.4 min) compared with the unassisted CPR group (35.6 ± 24.2 min) and the dispatcher-assisted full CPR group (44.5 ± 10.8 min). Correct rescue ventilation was given in 3.1 ± 11.1% (unassisted CPR) and 1.6 ± 16.1% (dispatcher-assisted full CPR) of all ventilation attempts. Best quality of CPR was achieved by DACO-CPR because of superior compression frequencies and reduced NFT. In contrast, the full dispatcher-assisted CPR with a longer initial instructing phase (initial NFT) did not result in enhanced CPR quality or an optimised compression depth.

  20. The optimal number of personnel for good quality of chest compressions: A prospective randomized parallel manikin trial

    PubMed Central

    Huh, Ji Young; Nishiyama, Kei; Hayashi, Hiroyuki

    2017-01-01

    Background Long durational chest compression (CC) deteriorates cardiopulmonary resuscitation (CPR) quality. The appropriate number of CC personnel for minimizing rescuer’s fatigue is mostly unknown. Objective We determined the optimal number of personnel needed for 30-min CPR in a rescue-team. Methods We conducted a randomized, manikin trial on healthcare providers. We divided them into Groups A to D according to the assigned different rest period to each group between the 2 min CCs. Groups A, B, C, and D performed CCs at 2, 4, 6, and 8 min rest period. All participants performed CCs for 30 min with a different rest period; participants allocated to Groups A, B, C, and D performed, eight, five, four, and three cycles, respectively. We compared a quality change of CCs among these groups to investigate how the assigned rest period affects the maintenance of CC quality during the 30-min CPR. Results This study involved 143 participants (male 58 [41%]; mean age, 24 years,) for the evaluation. As participants had less rest periods, the quality of their CCs such as sufficient depth ratio declined over 30-min CPR. A significant decrease in the sufficient CC depth ratio was observed in the second to the last cycle as compared to the first cycle. (median changes; A: −4%, B: −3%, C: 0%, and D: 0% p < 0.01). Conclusions A 6 min rest period after 2 min CC is vital in order to sustain the quality of CC during a 30-min CPR cycle. At least four personnel may be needed to reduce rescuer's fatigue for a 30-min CPR cycle when the team consists of men and women. PMID:29267300

  1. Helicopter-based in-water resuscitation with chest compressions: a pilot study.

    PubMed

    Winkler, Bernd E; Hartig, Frank; DuCanto, James; Koch, Andreas; Georgieff, Michael; Lungwitz, Yannick P; Muth, Claus-Martin

    2015-07-01

    Drowning is a relevant worldwide cause of severe disability and death. The delay of ventilations and chest compressions is a crucial problem in drowning victims. Hence, a novel helicopter-based ALS rescue concept with in-water ventilation and chest compressions was evaluated. Cardio pulmonary resuscitation (CPR) and vascular access were performed in a self-inflating Heliboat platform in an indoor wave pool using the Fastrach intubating laryngeal mask, the Oxylator resuscitator, Lund University Cardiopulmonary Assist System (LUCAS) chest compression device and EZ-IO intraosseous power drill. The time requirement and physical exertion on a Visual Analogue Scale (VAS) were compared between a procedure without waves and with moderate swell. Measurement of the elapsed time of the various stages of the procedure did not reveal significant differences between calm water and swell: Ventilation was initiated after 02:48 versus 03:02 and chest compression after 04:20 versus 04:18 min; the intraosseous cannulisation was completed after 05:59 versus 06:30 min after a simulated jump off the helicopter. The attachment of the LUCAS to the mannequin and the intraosseous cannulisation was rated significantly more demanding on the VAS during swell conditions. CPR appears to be possible when performed in a rescue platform with special equipment. The novel helicopter-based strategy appears to enable the rescuers to initiate CPR in an appropriate length of time and with an acceptable amount of physical exertion for the divers. The time for the helicopter to reach the patient will have to be very short to minimise neurological damage in the drowning victim. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Resuscitation quality assurance for out-of-hospital cardiac arrest--setting-up an ambulance defibrillator telemetry network.

    PubMed

    Lyon, R M; Clarke, S; Gowens, P; Egan, G; Clegg, G R

    2010-12-01

    Out-of-hospital cardiac arrest (OHCA) is a leading cause of pre-hospital mortality. Chest compressions performed during cardiopulmonary resuscitation aim to provide adequate perfusion to the vital organs during cardiac arrest. Poor resuscitation technique and the quality of pre-hospital CPR influences outcome from OHCA. Transthoracic impedance (TTI) measurement is a useful tool in the assessment of the quality of pre-hospital resuscitation by ambulance crews but TTI telemetry has not yet been performed in the United Kingdom. We describe a pilot study to implement a data network to collect defibrillator TTI data via telemetry from ambulances. Prospective, observational pilot study over a 5-month period. Modems were fitted to 40 defibrillators on ambulances based in Edinburgh. TTI data was sent to a receiving computer after resuscitation attempts for OHCA. 58 TTI traces were transmitted during the pilot period. Compliance with the telemetry system was high. The mean ratio of chest compressions was 73% (95% CI 69-77%), the mean chest compression rate was 128 (95% CI 122-134). The mean time interval from chest compression interruption to shock delivery was 27 s (95% CI 22-32 s). Trans-thoracic impedance analysis is an effective means of recording important measures of resuscitation quality including the hands-on-the-chest time, compression rate and defibrillation interval time. TTI data transmission via telemetry is straightforward, efficient and allows resuscitation data to be captured and analysed from a large geographical area. Further research is warranted on the impact of post-resuscitation reporting on the quality of resuscitation delivered by ambulance crews. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. The effects of flipped learning for bystander cardiopulmonary resuscitation on undergraduate medical students.

    PubMed

    Nakanishi, Taizo; Goto, Tadahiro; Kobuchi, Taketsune; Kimura, Tetsuya; Hayashi, Hiroyuki; Tokuda, Yasuharu

    2017-12-22

    To compare bystander cardiopulmonary resuscitation skills retention between conventional learning and flipped learning for first-year medical students. A post-test only control group design. A total of 108 participants were randomly assigned to either the conventional learning or flipped learning. The primary outcome measures of time to the first chest compression and the number of total chest compressions during a 2-minute test period 6 month after the training were assessed with the Mann-Whitney U test. Fifty participants (92.6%) in the conventional learning group and 45 participants (83.3%) in the flipped learning group completed the study. There were no statistically significant differences 6 months after the training in the time to the first chest compression of 33.0 seconds (interquartile range, 24.0-42.0) for the conventional learning group and 31.0 seconds (interquartile range, 25.0-41.0) for the flipped learning group (U=1171.0, p=0.73) or in the number of total chest compressions of 101.5 (interquartile range, 90.8-124.0) for the conventional learning group and 104.0 (interquartile range, 91.0-121.0) for the flipped learning group (U=1083.0, p=0.75). The 95% confidence interval of the difference between means of the number of total chest compressions 6 months after the training did not exceed a clinically important difference defined a priori. There were no significant differences between the conventional learning group and the flipped learning group in our main outcomes. Flipped learning might be comparable to conventional learning, and seems a promising approach which requires fewer resources and enables student-centered learning without compromising the acquisition of CPR skills.

  4. [Pulmonary atelectasis in patients with neurological or muscular disease; gravity-related lung compression by the heart and intra-abdominal organs on persistent supine position].

    PubMed

    Toyoshima, Mitsuo; Maeoka, Yukinori; Kawahara, Hitoshi; Maegaki, Yoshihiro; Ohno, Kousaku

    2006-11-01

    We report 10 cases of pulmonary atelectasis diagnosed by chest computed tomography in patients with neurological or muscular disease. Atelectasis was frequently seen in hypotonic patients who could not roll over on their own. The atelectases located mostly in the dorsal bronchopulmonary segments, adjacent to the heart or diaphragm. Atelectasis diminished in two patients after they became able to roll themselves over. Gravity-related lung compression by the heart and intra-abdominal organs on persistent supine position can cause pulmonary atelectasis in patients with neurological or muscular disease who can not roll over by their own power. To confirm that the prone position reduces compression of the lungs, chest computed tomography was performed in both the supine and the prone position in three patients. Sagittal images with three-dimensional computed tomographic reconstruction revealed significant sternad displacements of the heart and caudal displacements of the dorsal portion of the diaphragm on prone position compared with supine position. The prone position, motor exercises for rolling over, and biphasic cuirass ventilation are effective in reducing gravity-related lung compression. Some patients with intellectual disabilities were also able to cooperate in chest physiotherapy. Chest physiotherapy is useful in preventing atelectasis in patients with neurological or muscular disease.

  5. A Dosimetric Study on Slab-pinewood-slab Phantom for Developing the Heterogeneous Chest Phantom Mimicking Actual Human Chest

    PubMed Central

    Gurjar, Om Prakash; Paliwal, Radha Kishan; Mishra, Surendra Prasad

    2017-01-01

    The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS) phantom, solid phantom SP34 (made up of polystyrene), and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm × 10 cm was directed perpendicular to the surface of computed tomography (CT) images of chest level of patient, SPS phantom, and SP34 phantom. Dose was calculated using anisotropic analytical algorithm. Hounsfield units were used to calculate the density of each medium. Isodose depths in all the three sets of CT images were measured. Variations between planned doses on treatment planning system (TPS) and measured on linear accelerator (LA) were calculated for three points, namely, near slab–pinewood interfaces (6 and 18 cm depths) and 10 cm depth in SPS phantom and at the same depths in SP34 phantom. Density of pinewood, SP34 slabs, chest wall, lung, and soft tissue behind lung was measured as 0.329 ± 0.08, 0.999 ± 0.02, 0.898 ± 0.02, 0.291 ± 0.12, and 1.002 ± 0.03 g/cc, respectively. Depths of 100% and 90% isodose curves in all the three sets of CT images were found to be similar. Depths of 80%, 70%, 60%, 50%, and 40% isodose lines in SPS phantom images were found to be equivalent to that in chest images, while it was least in SP34 phantom images. Variations in doses calculated at 6, 10, and 18 cm depths on TPS and measured on LA were found to be 0.36%, 1.65%, and 2.23%, respectively, in case of SPS phantom, while 0.24%, 0.90%, and 0.93%, respectively, in case of SP34 slab phantom. SPS phantom seemed equivalent to the chest level of human body. Dosimetric results of this study indicate that patient-specific quality assurance can be done using chest phantom mimicking thoracic region of human body, which has been fabricated using polystyrene and pinewood. PMID:28706353

  6. Comparison of the quality of basic life support provided by rescuers trained using the 2005 or 2010 ERC guidelines.

    PubMed

    Jones, Christopher M; Owen, Andrew; Thorne, Christopher J; Hulme, Jonathan

    2012-08-09

    Effective delivery of cardiopulmonary resuscitation (CPR) and prompt defibrillation following sudden cardiac arrest (SCA) is vital. Updated guidelines for adult basic life support (BLS) were published in 2010 by the European Resuscitation Council (ERC) in an effort to improve survival following SCA. There has been little assessment of the ability of rescuers to meet the standards outlined within these new guidelines. We conducted a retrospective analysis of the performance of first year healthcare students trained and assessed using either the new 2010 ERC guidelines or their 2005 predecessor, within the University of Birmingham, United Kingdom. All students were trained as lay rescuers during a standardised eight hour ERC-accredited adult BLS course. We analysed the examination records of 1091 students. Of these, 561 were trained and assessed using the old 2005 ERC guidelines and 530 using the new 2010 guidelines. A significantly greater proportion of candidates failed in the new guideline group (16.04% vs. 11.05%; p < 0.05), reflecting a significantly greater proportion of lay-rescuers performing chest compressions at too fast a rate when trained and assessed with the 2010 rather than 2005 guidelines (6.04% vs. 2.67%; p < 0.05). Error rates for other skills did not differ between guideline groups. The new ERC guidelines lead to a greater proportion of lay rescuers performing chest compressions at an erroneously fast rate and may therefore worsen BLS efficacy. Additional study is required in order to define the clinical impact of compressions performed to a greater depth and at too fast a rate.

  7. Analysis of bystander CPR quality during out-of-hospital cardiac arrest using data derived from automated external defibrillators.

    PubMed

    Fernando, Shannon M; Vaillancourt, Christian; Morrow, Stanley; Stiell, Ian G

    2018-07-01

    Little is known regarding the quality of cardiopulmonary resuscitation (CPR) performed by bystanders in out-of-hospital cardiac arrest (OHCA). We sought to determine quality of bystander CPR provided during OHCA using CPR quality data stored by Automated External Defibrillators (AEDs). We used the Resuscitation Outcomes Consortium database to identify OHCA cases of presumed cardiac etiology where an AED was utilized. We then matched AED data to each case identified. AED data was analyzed using manufacturer software in order to determine overall measures of bystander CPR quality, changes in bystander CPR quality over time, and adherence to existing 2010 Resuscitation Quality Guidelines. 100 cases of OHCA of presumed cardiac etiology involving bystander CPR and with corresponding AED data. Mean age was 62.3 years, and 75% were male. Bystanders demonstrated high-quality CPR over all minutes of resuscitation, with a chest compression fraction of 76%, a compression depth of 5.3 cm, and a compression rate of 111.2 compressions/min. Mean perishock pause was 26.8 s. Adherence rates to 2010 Resuscitation Guidelines for compression rate and depth were found to be 66% and 55%, respectively. CPR quality was lowest in the first minute, resulting from increased delay to rhythm analysis (mean 40.7 s). In cases involving shock delivery, latency from initiation of AED to shock delivery was 59.2 s. We found that bystanders perform high-quality CPR, with strong adherence rates to existing Resuscitation Guidelines. High-quality CPR is maintained over the first five minutes of resuscitation, but was lowest in the first minute. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Cardiac compression due to gastric volvulus: an unusual cause of chest pain.

    PubMed

    Brown, Alex; Austin, David; Kanakala, Venkatesh

    2017-05-22

    A 42-year-old man was admitted to coronary care for assessment with severe retrosternal chest pain. Echocardiography showed significant external compression of the left atrium. A subsequent CT scan revealed him to have a large hiatus hernia, with most of his stomach herniating into his thorax causing left atrial compression and gastric volvulus. He subsequently underwent successful emergency decompression of the gastric volvulus and repair of his hiatus hernia. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Revolving back to the basics in cardiopulmonary resuscitation.

    PubMed

    Roppolo, L P; Wigginton, J G; Pepe, P E

    2009-05-01

    Since the 1970s, most of the research and debate regarding interventions for cardiopulmonary arrest have focused on advanced life support (ALS) therapies and early defibrillation strategies. During the past decade, however, international guidelines for cardiopulmonary resuscitation (CPR) have not only emphasized the concept of uninterrupted chest compressions, but also improvements in the timing, rate and quality of those compressions. In essence, it has been a ''revolution'' in resuscitation medicine in terms of ''coming full circle'' to the 1960s when basic CPR was first developed. Recent data have indicated the need for minimally-interrupted chest compressions with an accompanying emphasis toward removing rescue ventilation altogether in sudden cardiac arrest, at least in the few minutes after a sudden unheralded collapse. In other studies, transient delays in defibrillation attempts and ALS interventions are even recommended so that basic CPR can be prioritized to first restore and maintain better coronary artery perfusion. New devices have now been developed to modify, in real-time, the performance of basic CPR, during both training and an actual resuscitative effort. Several new adjuncts have been created to augment chest compressions or enhance venous return and evolving technology may now be able to identify ventricular fibrillation (VF) without interrupting chest compressions. A renewed focus on widespread CPR training for the average person has also returned to center stage with ground-breaking training initiatives including validated video-based adult learning courses that can reliably teach and enable long term retention of basic CPR skills and automated external defibrillator (AED) use.

  10. Tracheal intubation during pediatric cardiopulmonary resuscitation: A videography-based assessment in an emergency department resuscitation room.

    PubMed

    Donoghue, Aaron; Hsieh, Ting-Chang; Nishisaki, Akira; Myers, Sage

    2016-02-01

    To describe procedural characteristics of tracheal intubation (TI) during cardiopulmonary resuscitation (CPR) in a pediatric emergency department, and to characterize interruptions in CPR associated with TI performance. Retrospective single center case series. Resuscitations in a pediatric ED are videorecorded for quality improvement. Children who underwent TI while receiving chest compressions were eligible for inclusion. Intubations done by methods other than direct laryngoscopy were excluded. Background data included patient age and training background of intubator. Data on intubation attempts (success, laryngoscopy time) and chest compressions (interruptions, duration of pauses) were collected. Between December 2012 and February 2014, 32 patients had 59 TI attempts performed during CPR. Overall first attempt success at TI was 15/32 (47%); a median of 2 attempts were made per patient (range 1 to 4). Median laryngoscopy time was 47s (range 8-115s). 32/59 (54%) TI attempts had an associated interruption in CPR; the median interruption duration was 25s (range 3-64s). TI attempts without interruption in CPR were successful in 20/32 (63%) compared to 11/27 (41%) when CPR was paused (p=0.09). Laryngoscopy time was not significantly different between TI attempts with (47±21s) and without (47±26s; p=0.2) interruptions in compressions. 25/32 (78%) of pauses exceeded 10s in duration. TI during pediatric CPR results in significant interruptions in chest compressions. Procedural outcomes were not significantly different between attempts with and without compressions paused. In children receiving CPR, TI should be performed without pausing chest compressions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Histological Changes in the Thyroid Gland in Cases of Infant and Early Childhood Asphyxia-A Preliminary Study.

    PubMed

    Byard, Roger W; Bellis, Maria

    2016-05-01

    A retrospective blinded study of thyroid gland histology was undertaken in 50 infants and young children aged from 1 to 24 months. Deaths were due to (i) suffocation (N = 7), hanging (4), wedging (3), and chest and/or neck compression (4), and (ii) SIDS (20), noncervical trauma (7), organic disease, (4) and drug toxicity (1). In the asphyxia group (N = 18), thyroid gland congestion ranged from 0 to 3+ with 39% of cases (7/18) having moderate/marked congestion. In three cases, focal aggregates of red blood cells (blood islands) were observed within the intrafollicular colloid. These deaths involved chest compression, chest and/or neck compression, and crush asphyxia in a vehicle accident, and all had facial petechiae. Only 22% of the 32 control cases (7/32) had moderate/marked congestion with no blood islands being identified (p < 0.05). Blood islands within the thyroid gland may be caused by congestion associated with crushing or compression and may provide supportive evidence for this diagnosis. © 2016 American Academy of Forensic Sciences.

  12. Resuscitator’s perceptions and time for corrective ventilation steps during neonatal resuscitation☆

    PubMed Central

    Sharma, Vinay; Lakshminrusimha, Satyan; Carrion, Vivien; Mathew, Bobby

    2016-01-01

    Background The 2010 neonatal resuscitation program (NRP) guidelines incorporate ventilation corrective steps (using the mnemonic – MRSOPA) into the resuscitation algorithm. The perception of neonatal providers, time taken to perform these maneuvers or the effectiveness of these additional steps has not been evaluated. Methods Using two simulated clinical scenarios of varying degrees of cardiovascular compromise –perinatal asphyxia with (i) bradycardia (heart rate – 40 min−1) and (ii) cardiac arrest, 35 NRP certified providers were evaluated for preference to performing these corrective measures, the time taken for performing these steps and time to onset of chest compressions. Results The average time taken to perform ventilation corrective steps (MRSOPA) was 48.9 ± 21.4 s. Providers were less likely to perform corrective steps and proceed directly to endotracheal intubation in the scenario of cardiac arrest as compared to a state of bradycardia. Cardiac compressions were initiated significantly sooner in the scenario of cardiac arrest 89 ± 24 s as compared to severe bradycardia 122 ± 23 s, p < 0.0001. There were no differences in the time taken to initiation of chest compressions between physicians or mid-level care providers or with the level of experience of the provider. Conclusions Effective ventilation of the lungs with corrective steps using a mask is important in most cases of neonatal resuscitation. Neonatal resuscitators prefer early endotracheal intubation and initiation of chest compressions in the presence of asystolic cardiac arrest. Corrective ventilation steps can potentially postpone initiation of chest compressions and may delay return of spontaneous circulation in the presence of severe cardiovascular compromise. PMID:25796996

  13. Influence of learning styles on the practical performance after the four-step basic life support training approach – An observational cohort study

    PubMed Central

    Henke, Alexandra; Stieger, Lina; Beckers, Stefan; Biermann, Henning; Rossaint, Rolf; Sopka, Saša

    2017-01-01

    Background Learning and training basic life support (BLS)—especially external chest compressions (ECC) within the BLS-algorithm—are essential resuscitation training for laypersons as well as for health care professionals. The objective of this study was to evaluate the influence of learning styles on the performance of BLS and to identify whether all types of learners are sufficiently addressed by Peyton’s four-step approach for BLS training. Methods A study group of first-year medical students (n = 334) without previous medical knowledge was categorized according to learning styles using the German Lernstilinventar questionnaire based on Kolb’s Learning Styles Inventory. Students’ BLS performances were assessed before and after a four-step BLS training approach lasting 4 hours. Standardized BLS training was provided by an educational staff consisting of European Resuscitation Council-certified advanced life support providers and instructors. Pre- and post-intervention BLS performance was evaluated using a single-rescuer-scenario and standardized questionnaires (6-point-Likert-scales: 1 = completely agree, 6 = completely disagree). The recorded points of measurement were the time to start, depth, and frequency of ECC. Results The study population was categorized according to learning styles: diverging (5%, n = 16), assimilating (36%, n = 121), converging (41%, n = 138), and accommodating (18%, n = 59). Independent of learning styles, both male and female participants showed significant improvement in cardiopulmonary resuscitation (CPR) performance. Based on the Kolb learning styles, no significant differences between the four groups were observed in compression depth, frequency, time to start CPR, or the checklist-based assessment within the baseline assessment. A significant sex effect on the difference between pre- and post-interventional assessment points was observed for mean compression depth and mean compression frequency. Conclusions The findings of this work show that the four-step-approach for BLS training addresses all types of learners independent of their learning styles and does not lead to significant differences in the performance of CPR. PMID:28542636

  14. Influence of learning styles on the practical performance after the four-step basic life support training approach - An observational cohort study.

    PubMed

    Schröder, Hanna; Henke, Alexandra; Stieger, Lina; Beckers, Stefan; Biermann, Henning; Rossaint, Rolf; Sopka, Saša

    2017-01-01

    Learning and training basic life support (BLS)-especially external chest compressions (ECC) within the BLS-algorithm-are essential resuscitation training for laypersons as well as for health care professionals. The objective of this study was to evaluate the influence of learning styles on the performance of BLS and to identify whether all types of learners are sufficiently addressed by Peyton's four-step approach for BLS training. A study group of first-year medical students (n = 334) without previous medical knowledge was categorized according to learning styles using the German Lernstilinventar questionnaire based on Kolb's Learning Styles Inventory. Students' BLS performances were assessed before and after a four-step BLS training approach lasting 4 hours. Standardized BLS training was provided by an educational staff consisting of European Resuscitation Council-certified advanced life support providers and instructors. Pre- and post-intervention BLS performance was evaluated using a single-rescuer-scenario and standardized questionnaires (6-point-Likert-scales: 1 = completely agree, 6 = completely disagree). The recorded points of measurement were the time to start, depth, and frequency of ECC. The study population was categorized according to learning styles: diverging (5%, n = 16), assimilating (36%, n = 121), converging (41%, n = 138), and accommodating (18%, n = 59). Independent of learning styles, both male and female participants showed significant improvement in cardiopulmonary resuscitation (CPR) performance. Based on the Kolb learning styles, no significant differences between the four groups were observed in compression depth, frequency, time to start CPR, or the checklist-based assessment within the baseline assessment. A significant sex effect on the difference between pre- and post-interventional assessment points was observed for mean compression depth and mean compression frequency. The findings of this work show that the four-step-approach for BLS training addresses all types of learners independent of their learning styles and does not lead to significant differences in the performance of CPR.

  15. Quality of resuscitation: flight attendants in an airplane simulator use a new mechanical resuscitation device--a randomized simulation study.

    PubMed

    Fischer, Henrik; Neuhold, Stephanie; Hochbrugger, Eva; Steinlechner, Barbara; Koinig, Herbert; Milosevic, Ljubisa; Havel, Christof; Frantal, Sophie; Greif, Robert

    2011-04-01

    Cardiopulmonary resuscitation (CPR) during flight is challenging and has to be sustained for long periods. In this setting a mechanical-resuscitation-device (MRD) might improve performance. In this study we compared the quality of resuscitation of trained flight attendants practicing either standard basic life support (BLS) or using a MRD in a cabin-simulator. Prospective, open, randomized and crossover simulation study. Study participants, competent in standard BLS were trained to use the MRD to deliver both chest compressions and ventilation. 39 teams of two rescuers resuscitated a manikin for 12 min in random order, standard BLS or mechanically assisted resuscitation. Primary outcome was "absolute hands-off time" (sum of all periods during which no hand was placed on the chest minus ventilation time). Various parameters describing the quality of chest compression and ventilation were analysed as secondary outcome parameters. Use of the MRD led to significantly less "absolute hands-off time" (164±33 s vs. 205±42 s, p<0.001). The quality of chest compression was comparable among groups, except for a higher compression rate in the standard BLS group (123±14 min(-1) vs. 95±11 min(-1), p<0.001). Tidal volume was higher in the standard BLS group (0.48±0.14 l vs. 0.34±0.13 l, p<0.001), but we registered fewer gastric inflations in the MRD group (0.4±0.3% vs. 16.6±16.9%, p<0.001). Using the MRD resulted in significantly less "absolute hands-off time", but less effective ventilation. The translation of higher chest compression rate into better outcome, as shown in other studies previously, has to be investigated in another human outcome study. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. A feasibility study of cerebral oximetry during in-hospital mechanical and manual cardiopulmonary resuscitation*.

    PubMed

    Parnia, Sam; Nasir, Asad; Ahn, Anna; Malik, Hanan; Yang, Jie; Zhu, Jiawen; Dorazi, Francis; Richman, Paul

    2014-04-01

    A major hurdle limiting the ability to improve the quality of resuscitation has been the lack of a noninvasive real-time detection system capable of monitoring the quality of cerebral and other organ perfusion, as well as oxygen delivery during cardiopulmonary resuscitation. Here, we report on a novel system of cerebral perfusion targeted resuscitation. An observational study evaluating the role of cerebral oximetry (Equanox; Nonin, Plymouth, MI, and Invos; Covidien, Mansfield, MA) as a real-time marker of cerebral perfusion and oxygen delivery together with the impact of an automated mechanical chest compression system (Life Stat; Michigan Instruments, Grand Rapids, MI) on oxygen delivery and return of spontaneous circulation following in-hospital cardiac arrest. Tertiary medical center. In-hospital cardiac arrest patients (n = 34). Cerebral oximetry provided real-time information regarding the quality of perfusion and oxygen delivery. The use of automated mechanical chest compression device (n = 12) was associated with higher regional cerebral oxygen saturation compared with manual chest compression device (n = 22) (53.1% ± 23.4% vs 24% ± 25%, p = 0.002). There was a significant difference in mean regional cerebral oxygen saturation (median % ± interquartile range) in patients who achieved return of spontaneous circulation (n = 15) compared with those without return of spontaneous circulation (n = 19) (47.4% ± 21.4% vs 23% ± 18.42%, p < 0.001). After controlling for patients achieving return of spontaneous circulation or not, significantly higher mean regional cerebral oxygen saturation levels during cardiopulmonary resuscitation were observed in patients who were resuscitated using automated mechanical chest compression device (p < 0.001). The integration of cerebral oximetry into cardiac arrest resuscitation provides a novel noninvasive method to determine the quality of cerebral perfusion and oxygen delivery to the brain. The use of automated mechanical chest compression device during in-hospital cardiac arrest may lead to improved oxygen delivery and organ perfusion.

  17. Compression asphyxia from a human pyramid.

    PubMed

    Tumram, Nilesh Keshav; Ambade, Vipul Namdeorao; Biyabani, Naushad

    2015-12-01

    In compression asphyxia, respiration is stopped by external forces on the body. It is usually due to an external force compressing the trunk such as a heavy weight on the chest or abdomen and is associated with internal injuries. In present case, the victim was trapped and crushed under the falling persons from a human pyramid formation for a "Dahi Handi" festival. There was neither any severe blunt force injury nor any significant pathological natural disease contributing to the cause of death. The victim was unable to remove himself from the situation because his cognitive responses and coordination were impaired due to alcohol intake. The victim died from asphyxia due to compression of his chest and abdomen. Compression asphyxia resulting from the collapse of a human pyramid and the dynamics of its impact force in these circumstances is very rare and is not reported previously to the best of our knowledge. © The Author(s) 2015.

  18. Virtual arterial blood pressure feedback improves chest compression quality during simulated resuscitation.

    PubMed

    Rieke, Horst; Rieke, Martin; Gado, Samkon K; Nietert, Paul J; Field, Larry C; Clark, Carlee A; Furse, Cory M; McEvoy, Matthew D

    2013-11-01

    Quality chest compressions (CC) are the most important factor in successful cardiopulmonary resuscitation. Adjustment of CC based upon an invasive arterial blood pressure (ABP) display would be theoretically beneficial. Additionally, having one compressor present for longer than a 2-min cycle with an ABP display may allow for a learning process to further maximize CC. Accordingly, we tested the hypothesis that CC can be improved with a real-time display of invasively measured blood pressure and with an unchanged, physically fit compressor. A manikin was attached to an ABP display derived from a hemodynamic model responding to parameters of CC rate, depth, and compression-decompression ratio. The area under the blood pressure curve over time (AUC) was used for data analysis. Each participant (N=20) performed 4 CPR sessions: (1) No ABP display, exchange of compressor every 2 min; (2) ABP display, exchange of compressor every 2 min; (3) no ABP display, no exchange of the compressor; (4) ABP display, no exchange of the compressor. Data were analyzed by ANOVA. Significance was set at a p-value<0.05. The average AUC for cycles without ABP display was 5201 mm Hgs (95% confidence interval (CI) of 4804-5597 mm Hgs), and for cycles with ABP display 6110 mm Hgs (95% CI of 5715-6507 mm Hgs) (p<0.0001). The average AUC increase with ABP display for each participant was 20.2±17.4% 95 CI (p<0.0001). Our study confirms the hypothesis that a real-time display of simulated ABP during CPR that responds to participant performance improves achieved and sustained ABP. However, without any real-time visual feedback, even fit compressors demonstrated degradation of CC quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Teaching basic life support with an automated external defibrillator using the two-stage or the four-stage teaching technique.

    PubMed

    Bjørnshave, Katrine; Krogh, Lise Q; Hansen, Svend B; Nebsbjerg, Mette A; Thim, Troels; Løfgren, Bo

    2018-02-01

    Laypersons often hesitate to perform basic life support (BLS) and use an automated external defibrillator (AED) because of self-perceived lack of knowledge and skills. Training may reduce the barrier to intervene. Reduced training time and costs may allow training of more laypersons. The aim of this study was to compare BLS/AED skills' acquisition and self-evaluated BLS/AED skills after instructor-led training with a two-stage versus a four-stage teaching technique. Laypersons were randomized to either two-stage or four-stage teaching technique courses. Immediately after training, the participants were tested in a simulated cardiac arrest scenario to assess their BLS/AED skills. Skills were assessed using the European Resuscitation Council BLS/AED assessment form. The primary endpoint was passing the test (17 of 17 skills adequately performed). A prespecified noninferiority margin of 20% was used. The two-stage teaching technique (n=72, pass rate 57%) was noninferior to the four-stage technique (n=70, pass rate 59%), with a difference in pass rates of -2%; 95% confidence interval: -18 to 15%. Neither were there significant differences between the two-stage and four-stage groups in the chest compression rate (114±12 vs. 115±14/min), chest compression depth (47±9 vs. 48±9 mm) and number of sufficient rescue breaths between compression cycles (1.7±0.5 vs. 1.6±0.7). In both groups, all participants believed that their training had improved their skills. Teaching laypersons BLS/AED using the two-stage teaching technique was noninferior to the four-stage teaching technique, although the pass rate was -2% (95% confidence interval: -18 to 15%) lower with the two-stage teaching technique.

  20. [European Resuscitation Council guidelines for resuscitation 2010].

    PubMed

    Hunyadi-Anticević, Silvija; Colak, Zeljko; Funtak, Ines Lojna; Lukić, Anita; Filipović-Grcić, Boris; Tomljanović, Branka; Kniewald, Hrvoje; Protić, Alen; Pandak, Tatjana; Poljaković, Zdravka; Canadija, Marino

    2011-01-01

    All rescuers trained or not, should provide chest compressions to victims of cardiac arrest. The aim should be to push to a depth of at least 5 cm at a rate of at least 100 compressions per minute, to allow full chest recoil, and to minimise interruptions in chest compressions. Trained rescuers should also provide ventilations with a compression-ventilation ratio of 30:2. ELECTRICAL THERAPIES: Much greater emphasis on minimising the duration of the pre-shock and post-shock pauses; the continuation of compressions during charging of the defibrillator is recommended. Further development of AED programmes is encouraged. ADULT ADVANCED LIFE SUPPORT: Increased emphasis on high-quality chest compressions throughout any ALS intervention paused briefly only to enable specific interventions. Removal of the recommendation for a pre-specified period of cardiopulmonary resuscitation before out-of-hospital defibrillation following cardiac arrest unwitnessed by the EMS. The role of precordial thump is de-emphasized. Delivery of drugs via a tracheal tube is no longer recommended, drugs should be given by the intraosseous (IO) route. Atropine is no longer recommended for routine use in asystole or pulseless electrical activity. Reduced emphasis on early tracheal intubation unless achieved by highly skilled individuals with minimal interruptions in chest compressions. Increased emphasis on the use of capnography. Recognition of potential harm caused by hyperoxaemia. Revision of the recommendation of glucose control. Use of therapeutic hypothermia to include comatose survivors of cardiac arrest associated initially with shockable rhythms, as well as non-shockable rhythms, with a lower level of evidence acknowledged for the latter. INITIAL MANAGEMENT OF ACUTE CORONARY SYNDROMES: The term non-ST-elevation myocardial infarction-acute coronary syndrome (non-STEMI-ACS) has been introduced for both NSTEMI and unstable angina pectoris. Primary PCI (PPCI) is the preferred reperfusion strategy provided it is performed in a timely manner by an experienced team. Non-steroidal anti-inflammatory drugs should be avoided, as well as routine use of intravenous beta-blockers; oxygen is to be given only to those patients with hypoxaemia, breathlessness or pulmonary congestion. PAEDIATRIC LIFE SUPPORT: The decision to begin resuscitation must be taken in less than 10 seconds. Lay rescuers should be taught to use a ratio of 30 compressions to 2 ventilations, rescuers with a duty to respond should learn and use a 15:2 ratio; however, they can use the 30:2 compression-ventilation ratio if they are alone. Ventilation remains a very important component of resuscitation in asphyxial arrest. The emphasis is on achieving quality compressions with the rate of at least 100 but not greater than 120 per minute, with minimal interruptions. AEDs are safe and successful when used in children older than 1 year. A single shock strategy using a non-escalating dose of 4 J/kg is recommended for defibrillation in children. Cuffed tubes can be used safely in infants and young children. Monitoring exhaled carbon dioxide (CO2), ideally by capnography, is recommended during resuscitation. RESUSCITATION OF BABIES AT BIRTH: For uncompromised babies, a delay in cord clamping of at least one minute from the complete delivery is now recommended. For term infants, air should be used fro resuscitation at birth. For preterm babies less than 32 weeks gestation blended oxygen and air should be given judiciously and its use guided by pulse oximetry. Preterm babies of less than 28 weeks gestation should be completely covered in a plastic wrap up to their necks, without drying, immediately after birth. The recommended compression: ventilation ratio remains at 3:1 for newborn resuscitation. Attempts to aspirate meconium from the nose and mouth of the unborn baby, while the head is still on the perineum, are not recommended. If adrenaline is given the n the intravenous route is recommended using a dose of 10-30 microg/kg. Newly born infants born at term or near-term with moderate to severe hypoxic-ischaemic encephalopathy should be treated with therapeutic hypothermia. PRINCIPLES OF EDUCATION IN RESUSCITATION: The aim is to ensure that learners acquire and retain skill and knowledge that will enable them to act correctly in actual cardiac arrest and improve patient outcome. Short video/computer self-instruction courses, with minimal or no instructor coaching, combined with hands-on practice can be considered as an effective alternative to instructor-led basic life support (BLS and AED) courses. Ideally all citizens should be trained in standard CPR that includes compressions and ventilations. Basic and advanced life support knowledge and skills deteriorate in as little as three to six months. CPR prompt or feedback devices improve CPR skill acquisition and retention.

  1. Development and evaluation of a novel lossless image compression method (AIC: artificial intelligence compression method) using neural networks as artificial intelligence.

    PubMed

    Fukatsu, Hiroshi; Naganawa, Shinji; Yumura, Shinnichiro

    2008-04-01

    This study was aimed to validate the performance of a novel image compression method using a neural network to achieve a lossless compression. The encoding consists of the following blocks: a prediction block; a residual data calculation block; a transformation and quantization block; an organization and modification block; and an entropy encoding block. The predicted image is divided into four macro-blocks using the original image for teaching; and then redivided into sixteen sub-blocks. The predicted image is compared to the original image to create the residual image. The spatial and frequency data of the residual image are compared and transformed. Chest radiography, computed tomography (CT), magnetic resonance imaging, positron emission tomography, radioisotope mammography, ultrasonography, and digital subtraction angiography images were compressed using the AIC lossless compression method; and the compression rates were calculated. The compression rates were around 15:1 for chest radiography and mammography, 12:1 for CT, and around 6:1 for other images. This method thus enables greater lossless compression than the conventional methods. This novel method should improve the efficiency of handling of the increasing volume of medical imaging data.

  2. Minimally invasive repair of pectus carinatum and how to deal with complications

    PubMed Central

    Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo

    2016-01-01

    While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient’s malformation. This molding is done using benders designed as part of the procedure. PMID:29078492

  3. Minimally invasive repair of pectus carinatum and how to deal with complications.

    PubMed

    Abramson, Horacio; Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo

    2016-01-01

    While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient's malformation. This molding is done using benders designed as part of the procedure.

  4. Comparison between an instructor-led course and training using a voice advisory manikin in initial cardiopulmonary resuscitation skill acquisition.

    PubMed

    Min, Mun Ki; Yeom, Seok Ran; Ryu, Ji Ho; Kim, Yong In; Park, Maeng Real; Han, Sang Kyoon; Lee, Seong Hwa; Park, Sung Wook; Park, Soon Chang

    2016-09-01

    We compared training using a voice advisory manikin (VAM) with an instructor-led (IL) course in terms of acquisition of initial cardiopulmonary resuscitation (CPR) skills, as defined by the 2010 resuscitation guidelines. This study was a randomized, controlled, blinded, parallel-group trial. We recruited 82 first-year emergency medical technician students and distributed them randomly into two groups: the IL group (n=41) and the VAM group (n=37). In the IL-group, participants were trained in "single-rescuer, adult CPR" according to the American Heart Association's Basic Life Support course for healthcare providers. In the VAM group, all subjects received a 20-minute lesson about CPR. After the lesson, each student trained individually with the VAM for 1 hour, receiving real-time feedback. After the training, all subjects were evaluated as they performed basic CPR (30 compressions, 2 ventilations) for 4 minutes. The proportion of participants with a mean compression depth ≥50 mm was 34.1% in the IL group and 27.0% in the VAM group, and the proportion with a mean compression depth ≥40 mm had increased significantly in both groups compared with ≥50 mm (IL group, 82.9%; VAM group, 86.5%). However, no significant differences were detected between the groups in this regard. The proportion of ventilations of the appropriate volume was relatively low in both groups (IL group, 26.4%; VAM group, 12.5%; P=0.396). Both methods, the IL training using a practice-while-watching video and the VAM training, facilitated initial CPR skill acquisition, especially in terms of correct chest compression.

  5. Code Team Training: Demonstrating Adherence to AHA Guidelines During Pediatric Code Blue Activations.

    PubMed

    Stewart, Claire; Shoemaker, Jamie; Keller-Smith, Rachel; Edmunds, Katherine; Davis, Andrew; Tegtmeyer, Ken

    2017-10-16

    Pediatric code blue activations are infrequent events with a high mortality rate despite the best effort of code teams. The best method for training these code teams is debatable; however, it is clear that training is needed to assure adherence to American Heart Association (AHA) Resuscitation Guidelines and to prevent the decay that invariably occurs after Pediatric Advanced Life Support training. The objectives of this project were to train a multidisciplinary, multidepartmental code team and to measure this team's adherence to AHA guidelines during code simulation. Multidisciplinary code team training sessions were held using high-fidelity, in situ simulation. Sessions were held several times per month. Each session was filmed and reviewed for adherence to 5 AHA guidelines: chest compression rate, ventilation rate, chest compression fraction, use of a backboard, and use of a team leader. After the first study period, modifications were made to the code team including implementation of just-in-time training and alteration of the compression team. Thirty-eight sessions were completed, with 31 eligible for video analysis. During the first study period, 1 session adhered to all AHA guidelines. During the second study period, after alteration of the code team and implementation of just-in-time training, no sessions adhered to all AHA guidelines; however, there was an improvement in percentage of sessions adhering to ventilation rate and chest compression rate and an improvement in median ventilation rate. We present a method for training a large code team drawn from multiple hospital departments and a method of assessing code team performance. Despite subjective improvement in code team positioning, communication, and role completion and some improvement in ventilation rate and chest compression rate, we failed to consistently demonstrate improvement in adherence to all guidelines.

  6. The influence of water depth on kinematic and spatiotemporal gait parameters during aquatic treadmill walking.

    PubMed

    Jung, Taeyou; Kim, Yumi; Lim, Hyosok; Vrongistinos, Konstantinos

    2018-01-16

    The purpose of this study was to investigate kinematic and spatiotemporal variables of aquatic treadmill walking at three different water depths. A total of 15 healthy individuals completed three two-minute walking trials at three different water depths. The aquatic treadmill walking was conducted at waist-depth, chest-depth and neck-depth, while a customised 3-D underwater motion analysis system captured their walking. Each participant's self-selected walking speed at the waist level was used as a reference speed, which was applied to the remaining two test conditions. A repeated measures ANOVA showed statistically significant differences among the three walking conditions in stride length, cadence, peak hip extension, hip range of motion (ROM), peak ankle plantar flexion and ankle ROM (All p values < 0.05). The participants walked with increased stride length and decreased cadence during neck level as compared to waist and chest level. They also showed increased ankle ROM and decreased hip ROM as the water depth rose from waist and chest to the neck level. However, our study found no significant difference between waist and chest level water in all variables. Hydrodynamics, such as buoyancy and drag force, in response to changes in water depths, can affect gait patterns during aquatic treadmill walking.

  7. Functions of standard CPR training on performance qualities of medical volunteers for Mt. Taishan International Mounting Festival.

    PubMed

    Fanshan, Meng; Lin, Zhao; Wenqing, Liu; Chunlei, Lu; Yongqiang, Liu; Naiyi, Li

    2013-01-01

    Cardiopulmonary resuscitation (CPR) is a sudden emergency procedure that requires a rapid and efficient response, and personnel training in lifesaving procedures. Regular practice and training are necessary to improve resuscitation skills and reduce anxiety among the staff. As one of the most important skills mastered by medical volunteers serving for Mt. Taishan International Mounting Festival, we randomly selected some of them to evaluate the quality of CPR operation and compared the result with that of the untrained doctors and nurses. In order to evaluate the functions of repeating standard CPR training on performance qualities of medical volunteers for Mt. Taishan International Mounting Festival, their performance qualities of CPR were compared with those of the untrained medical workers working in emergency departments of hospitals in Taian. The CPR performance qualities of 52 medical volunteers (Standard Training Group), who had continually taken part in standard CPR technical training for six months, were tested at random and were compared with those of 68 medical workers (Compared Group) working in emergency departments of hospitals in Taian who hadn't attended CPR training within a year. The QCPR 3535 monitor (provided by Philips Company) was used to measure the standard degree of single simulated CPR performance, including the chest compression depth, frequency, released pressure between compressions and performance time of compression and ventilation, the results of which were recorded in the table and the number of practical compression per minute was calculated. The data were analyzed by x2 Test and t Test. The factors which would influence CPR performance, including gender, age, placement, hand skill, posture of compression and frequency of training, were classified and given parameters, and were put to Logistic repression analysis. The CPR performance qualities of volunteers were much higher than those of the compared group. The overall pass rates were respectively 86.4% and 31.9%; the pass rates of medical volunteers in terms of the chest compression depth, frequency, released pressure between compressions were higher than those of the compared group, which were 89.6%, 94.2%, 95.8% vs 50.3%, 53.0%, 83.1%, P<0.01; there were few differences in overall performance time, which were (118.4 ± 13.5s) vs (116.0 ± 10.4s), P>0.05; the duration time of ventilation in each performance section was much shorter than that in the compared group, which were (6.38 ± 1.2) vs (7.47 ± 1.7), P<0.01; there were few differences in the number of practical compression per minute, which were (78.2 ± 3.5) vs (78.8 ± 12.2), P>0.05); the time proportion of compression and ventilation was 2.6:1 vs 2.1:1. The Logistic repression analysis showed that CPR performance qualities were clearly related to hand skill, posture of compression and repeating standard training, which were respectively OR 13.12 and 95%CI (2.35~73.2); OR 30.89, 95%CI (3.62~263.5); OR 4.07,95%CI (1.16~14.2). The CPR performance qualities of volunteers who had had repeating standard training were much higher than those of untrained medical workers, which proved that standard training helped improve CPR performance qualities.

  8. Factors affecting team leadership skills and their relationship with quality of cardiopulmonary resuscitation.

    PubMed

    Yeung, Joyce H Y; Ong, G J; Davies, Robin P; Gao, Fang; Perkins, Gavin D

    2012-09-01

    This study aims to explore the relationship between team-leadership skills and quality of cardiopulmonary resuscitation in an adult cardiac-arrest simulation. Factors affecting team-leadership skills were also assessed. Forty advanced life-support providers leading a cardiac arrest team in a standardized cardiac-arrest simulation were videotaped. Background data were collected, including age (in yrs), sex, whether they had received any leadership training in the past, whether they were part of a professional group, the most recent advanced life-support course (in months) they had undergone, advanced life-support instructor/provider status, and whether they had led in any cardiac arrest situation in the preceding 6 months. Participants were scored using the Cardiac Arrest Simulation test score and Leadership Behavior Description Questionnaire for leadership skills. Process-focused quality of cardiopulmonary resuscitation data were collected directly from manikin and video recordings. Primary outcomes were complex technical skills (measured as Cardiac Arrest Simulation test score, preshock pause, and hands-off ratio). Secondary outcomes were simple technical skills (chest-compression rate, depth, and ventilation rate). Univariate linear regressions were performed to examine how leadership skills affect quality of cardiopulmonary resuscitation and bivariate correlations elicited factors affecting team-leadership skills.Teams led by leaders with the best leadership skills performed higher quality cardiopulmonary resuscitation with better technical performance (R = 0.75, p < .001), shorter preshock pauses (R = 0.18, p < .001), with lower total hands-off ratio (R = 0.24, p = .01), and shorter time to first shock (R = 0.14, p = .02). Leadership skills were not significantly associated with more simple technical skills such as chest-compression rate, depth, and ventilation rate. Prior training in team leader skills was independently associated with better leadership behavior. There is an association between team leadership skills and cardiac arrest simulation test score, preshock pause, and hands off ratio. Developing leadership skills should be considered an integral part of resuscitation training.

  9. Resuscitation training in small-group setting – gender matters

    PubMed Central

    2013-01-01

    Background Within cardiopulmonary resuscitation external chest compressions (ECC) are of outstanding importance. Frequent training in Basic Life Support (BLS) may improve the performance, but the perfect method or environment is still a matter of research. The objective of this study was to evaluate whether practical performance and retention of skills in resuscitation training may be influenced by the gender composition in learning groups. Methods Participants were allocated to three groups for standardized BLS-training: Female group (F): only female participants; Male group (M): only male participants; Standard group (S): male and female participants. All groups were trained with the standardized 4-step-approach method. Assessment of participants’ performance was done before training (t1), after one week (t2) and eight months later (t3) on a manikin in the same cardiac arrest single-rescuer-scenario. Participants were 251 Laypersons (mean age 21; SD 4; range 18–42 years; females 63%) without previous medical knowledge. Endpoints: compression rate 90-110/min; mean compression depth 38–51 mm. Standardized questionnaires were used for the evaluation of attitude and learning environment. Results After one week group F performed significantly better with respect to the achievement of the correct mean compression depth (F: 63% vs. S: 43%; p = 0.02). Moreover, groups F and S were the only groups which were able to improve their performance concerning the mean compression rate (t1: 35%; t3: 52%; p = 0.04). Female participants felt more comfortable in the female–only environment. Conclusions Resuscitation training in gender-segregated groups has an effect on individual performance with superior ECC skills in the female-only learning groups. Female participants could improve their skills by a more suitable learning environment, while male participants in the standard group felt less distracted by their peers than male participants in the male-only group. PMID:23590998

  10. [Compressive anterior thoracoplasty (modified Abramson's repair) for pectus carinatum repair].

    PubMed

    Álvarez Muñoz, V; Prado Valle, M A; López López, A J; Martínez Suárez, M A; Oviedo Gutiérrez, M; Montalvo Ávalos, C; Fernández García, L

    2014-04-15

    For anterior protruding chest wall deformities treatment, mainly pectus carinatum, pediatric surgeons have been managing either orthotic methods or open surgical repairs. Anterior compressive thoracoplasty (Abramson's technique) has widened the therapeutic options. We describe herein a modification of this technique in the first reported Europen series. From 2010 to 2012, a total of five patients (four male and one female) underwent a modified Abramson's technique to correct pectus carinatum or combined protrusion of the chest at our center. We report the operative technique used for these reconstructions. In all five cases, the operation was completed uneventfully and with excellent results either for the surgical team or the patients. Mean operative time was 190 minutes and hospitalization lasted for three to six days, at the time of analgesic drugs withdrawal. We consider the anterior compresive thorocoplasty (modified Abramson's technique) a safe and feasible method to correct protruding chest deformities, particularly in those patients with stiff chest or lack of compliance, in order to avoid the agressive open procedures.

  11. Cystic Fibrosis Chest X-Ray Findings: A Teaching Analog

    DTIC Science & Technology

    2008-07-01

    lung volume. There are five specific types of atelectasis: obstructive, compressive, cicatrization , post-operative and adhesive. Obstructive...commonly, a pleural lesion or mass can cause impact on the neighboring lung tissue causing compression of the alveoli in that area. Cicatrization ...Lymphoma Atelectasis Obstructive Compressive Pneumothorax Pleural Effusion Pleural Lesion Cicatrization Radiation Severe Pneumonia Adhesive

  12. Chest compression rate measurement from smartphone video.

    PubMed

    Engan, Kjersti; Hinna, Thomas; Ryen, Tom; Birkenes, Tonje S; Myklebust, Helge

    2016-08-11

    Out-of-hospital cardiac arrest is a life threatening situation where the first person performing cardiopulmonary resuscitation (CPR) most often is a bystander without medical training. Some existing smartphone apps can call the emergency number and provide for example global positioning system (GPS) location like Hjelp 113-GPS App by the Norwegian air ambulance. We propose to extend functionality of such apps by using the built in camera in a smartphone to capture video of the CPR performed, primarily to estimate the duration and rate of the chest compression executed, if any. All calculations are done in real time, and both the caller and the dispatcher will receive the compression rate feedback when detected. The proposed algorithm is based on finding a dynamic region of interest in the video frames, and thereafter evaluating the power spectral density by computing the fast fourier transform over sliding windows. The power of the dominating frequencies is compared to the power of the frequency area of interest. The system is tested on different persons, male and female, in different scenarios addressing target compression rates, background disturbances, compression with mouth-to-mouth ventilation, various background illuminations and phone placements. All tests were done on a recording Laerdal manikin, providing true compression rates for comparison. Overall, the algorithm is seen to be promising, and it manages a number of disturbances and light situations. For target rates at 110 cpm, as recommended during CPR, the mean error in compression rate (Standard dev. over tests in parentheses) is 3.6 (0.8) for short hair bystanders, and 8.7 (6.0) including medium and long haired bystanders. The presented method shows that it is feasible to detect the compression rate of chest compressions performed by a bystander by placing the smartphone close to the patient, and using the built-in camera combined with a video processing algorithm performed real-time on the device.

  13. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...

  14. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...

  15. Metastatic spinal cord compression from basal cell carcinoma of the skin treated with surgical decompression and vismodegib: case report and review of Hedgehog signalling pathway inhibition in advanced basal cell carcinoma.

    PubMed

    McGrane, J; Carswell, S; Talbot, T

    2017-01-01

    We report a case of a 66-year-old man with locally advanced and metastatic basal cell carcinoma (BCC) causing spinal cord compression, which was treated with spinal surgery and subsequent vismodegib. The patient presented with a large fungating chest wall lesion and a metastasis in T8 that was causing cord compression. He had neurosurgical decompression of the T8 lesion and fixation of the spine. Punch biopsy from the fungating chest wall lesion showed a BCC with some malignant squamous differentiation (basosquamous). Histopathological examination of the metastatic lesion in T8 at the time of surgical decompression identified features identical to the punch biopsy. The patient was referred to the oncology clinic for adjuvant treatment. In light of his metastatic disease and the large area over his chest wall that could not fully be covered by radiotherapy, he was treated with the novel oral Hedgehog signalling pathway (HHSP) inhibitor vismodegib, which led to marked improvement. © 2016 British Association of Dermatologists.

  16. Evaluation of a novel basic life support method in simulated microgravity.

    PubMed

    Rehnberg, Lucas; Russomano, Thaws; Falcão, Felipe; Campos, Fabio; Everts, Simon N

    2011-02-01

    If a cardiac arrest occurs in microgravity, current emergency protocols aim to treat patients via a medical restraint system within 2-4 min. It is vital that crewmembers have the ability to perform single-person cardiopulmonary resuscitation (CPR) during this period, allowing time for advanced life support to be deployed. The efficacy of the Evetts-Russomano (ER) method has been tested in 22 s of microgravity in a parabolic flight and has shown that external chest compressions (ECC) and mouth-to-mouth ventilation are possible. There were 21 male subjects who performed both the ER method in simulated microgravity via full body suspension and at +1 Gz. The CPR mannequin was modified to provide accurate readings for ECC depth and a metronome to set the rate at 100 bpm. Heart rate, rate of perceived exertion, and angle of arm flexion were measured with an ECG, elbow electrogoniometers, and Borg scale, respectively. The mean (+/- SD) depth of ECC in simulated microgravity was lower in each of the 3 min compared to +1 G2. The ECC depth (45.7 +/- 2.7 mm, 42.3 +/- 5.5 mm, and 41.4 +/- 5.9 mm) and rate (104.5 +/- 5.2, 105.2 +/- 4.5, and 102.4 +/- 6.6 compressions/min), however, remained within CPR guidelines during simulated microgravity over the 3-min period. Heart rate, perceived exertion, and elbow flexion of both arms increased using the ER method. The ER method can provide adequate depth and rate of ECC in simulated microgravity for 3 min to allow time to deploy a medical restraint system. There is, however, a physiological cost associated with it and a need to use the flexion of the arms to compensate for the lack of weight.

  17. A randomised crossover comparison of mouth-to-face-shield ventilation and mouth-to-pocket-mask ventilation by surf lifeguards in a manikin.

    PubMed

    Adelborg, K; Bjørnshave, K; Mortensen, M B; Espeseth, E; Wolff, A; Løfgren, B

    2014-07-01

    Thirty surf lifeguards (mean (SD) age: 25.1 (4.8) years; 21 male, 9 female) were randomly assigned to perform 2 × 3 min of cardiopulmonary resuscitation on a manikin using mouth-to-face-shield ventilation (AMBU LifeKey) and mouth-to-pocket-mask ventilation (Laerdal Pocket Mask). Interruptions in chest compressions, effective ventilation (visible chest rise) ratio, tidal volume and inspiratory time were recorded. Interruptions in chest compressions per cycle were increased with mouth-to-face-shield ventilation (mean (SD) 8.6 (1.7) s) compared with mouth-to-pocket-mask ventilation (6.9 (1.2) s, p < 0.0001). The proportion of effective ventilations was less using mouth-to-face-shield ventilation (199/242 (82%)) compared with mouth-to-pocket-mask ventilation (239/240 (100%), p = 0.0002). Tidal volume was lower using mouth-to-face-shield ventilation (mean (SD) 0.36 (0.20) l) compared with mouth-to-pocket-mask ventilation (0.45 (0.20) l, p = 0.006). No differences in inspiratory times were observed between mouth-to-face-shield ventilation and mouth-to-pocket-mask ventilation. In conclusion, mouth-to-face-shield ventilation increases interruptions in chest compressions, reduces the proportion of effective ventilations and decreases delivered tidal volumes compared with mouth-to-pocket-mask ventilation. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  18. Mobile phone-assisted basic life support augmented with a metronome.

    PubMed

    Paal, Peter; Pircher, Iris; Baur, Thomas; Gruber, Elisabeth; Strasak, Alexander M; Herff, Holger; Brugger, Hermann; Wenzel, Volker; Mitterlechner, Thomas

    2012-09-01

    Basic life support (BLS) performed by lay rescuers is poor. We developed software for mobile phones augmented with a metronome to improve BLS. To assess BLS in lay rescuers with or without software assistance. Medically untrained volunteers were randomized to run through a cardiac arrest scenario with ("assisted BLS") or without ("non-assisted BLS") the aid of a BLS software program installed on a mobile phone. Sixty-four lay rescuers were enrolled in the "assisted BLS" and 77 in the "non-assisted BLS" group. The "assisted BLS" when compared to the "non-assisted BLS" group, achieved a higher overall score (19.2 ± 7.5 vs. 12.9 ± 5.7 credits; p < 0.001). Moreover, the "assisted BLS" when compared to the "non-assisted" group checked (64% vs. 27%) and protected themselves more often from environmental risks (70% vs. 39%); this group also called more often for help (56% vs. 27%), opened the upper airway (78% vs. 16%), and had more correct chest compressions rates (44% ± 38% vs. 14% ± 28%; all p < 0.001). However, the "assisted BLS" when compared to the "non-assisted BLS" group, was slower in calling the dispatch center (113.6 ± 86.4 vs. 54.1 ± 45.1 s; p < 0.001) and starting chest compressions (165.3 ± 93.3 vs. 87.1 ± 53.2 s; p < 0.001). "Assisted BLS" augmented by a metronome resulted in a higher overall score and a better chest compression rate when compared to "non-assisted BLS." However, in the "assisted BLS" group, time to call the dispatch center and to start chest compressions was longer. In both groups, lay persons did not ventilate satisfactorily during this cardiac arrest scenario. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Simulation-based Randomized Comparative Assessment of Out-of-Hospital Cardiac Arrest Resuscitation Bundle Completion by Emergency Medical Service Teams Using Standard Life Support or an Experimental Automation-assisted Approach.

    PubMed

    Choi, Bryan; Asselin, Nicholas; Pettit, Catherine C; Dannecker, Max; Machan, Jason T; Merck, Derek L; Merck, Lisa H; Suner, Selim; Williams, Kenneth A; Jay, Gregory D; Kobayashi, Leo

    2016-12-01

    Effective resuscitation of out-of-hospital cardiac arrest (OHCA) patients is challenging. Alternative resuscitative approaches using electromechanical adjuncts may improve provider performance. Investigators applied simulation to study the effect of an experimental automation-assisted, goal-directed OHCA management protocol on EMS providers' resuscitation performance relative to standard protocols and equipment. Two-provider (emergency medical technicians (EMT)-B and EMT-I/C/P) teams were randomized to control or experimental group. Each team engaged in 3 simulations: baseline simulation (standard roles); repeat simulation (standard roles); and abbreviated repeat simulation (reversed roles, i.e., basic life support provider performing ALS tasks). Control teams used standard OHCA protocols and equipment (with high-performance cardiopulmonary resuscitation training intervention); for second and third simulations, experimental teams performed chest compression, defibrillation, airway, pulmonary ventilation, vascular access, medication, and transport tasks with goal-directed protocol and resuscitation-automating devices. Videorecorders and simulator logs collected resuscitation data. Ten control and 10 experimental teams comprised 20 EMT-B's; 1 EMT-I, 8 EMT-C's, and 11 EMT-P's; study groups were not fully matched. Both groups suboptimally performed chest compressions and ventilations at baseline. For their second simulations, control teams performed similarly except for reduced on-scene time, and experimental teams improved their chest compressions (P=0.03), pulmonary ventilations (P<0.01), and medication administration (P=0.02); changes in their performance of chest compression, defibrillation, airway, and transport tasks did not attain significance against control teams' changes. Experimental teams maintained performance improvements during reversed-role simulations. Simulation-based investigation into OHCA resuscitation revealed considerable variability and improvable deficiencies in small EMS teams. Goal-directed, automation-assisted OHCA management augmented select resuscitation bundle element performance without comprehensive improvement.

  20. A simulation tool to study high-frequency chest compression energy transfer mechanisms and waveforms for pulmonary disease applications.

    PubMed

    O'Clock, George D; Lee, Yong Wan; Lee, Jongwon; Warwick, Warren J

    2010-07-01

    High-frequency chest compression (HFCC) can be used as a therapeutic intervention to assist in the transport and clearance of mucus and enhance water secretion for cystic fibrosis patients. An HFCC pump-vest and half chest-lung simulation, with 23 lung generations, has been developed using inertance, compliance, viscous friction relationships, and Newton's second law. The simulation has proven to be useful in studying the effects of parameter variations and nonlinear effects on HFCC system performance and pulmonary system response. The simulation also reveals HFCC waveform structure and intensity changes in various segments of the pulmonary system. The HFCC system simulation results agree with measurements, indicating that the HFCC energy transport mechanism involves a mechanically induced pulsation or vibration waveform with average velocities in the lung that are dependent upon small air displacements over large areas associated with the vest-chest interface. In combination with information from lung physiology, autopsies and a variety of other lung modeling efforts, the results of the simulation can reveal a number of therapeutic implications.

  1. The effects of an online basic life support course on undergraduate nursing students' learning.

    PubMed

    Tobase, Lucia; Peres, Heloisa H C; Gianotto-Oliveira, Renan; Smith, Nicole; Polastri, Thatiane F; Timerman, Sergio

    2017-08-25

    To describe learning outcomes of undergraduate nursing students following an online basic life support course (BLS). An online BLS course was developed and administered to 94 nursing students. Pre- and post-tests were used to assess theoretical learning. Checklist simulations and feedback devices were used to assess the cardiopulmonary resuscitation (CPR) skills of the 62 students who completed the course. A paired t-test revealed a significant increase in learning [pre-test (6.4 ± 1.61), post-test (9.3 ± 0.82), p < 0.001]. The increase in the average grade after taking the online course was significant (p<0.001). No learning differences (p=0.475) had been observed between 1st and 2nd year (9.20 ± 1.60), and between 3rd and 4th year (9.67 ± 0.61) students. A CPR simulation was performed after completing the course: students checked for a response (90%), exposed the chest (98%), checked for breathing (97%), called emergency services (76%), requested for a defibrillator (92%), checked for a pulse (77%), positioned their hands properly (87%), performed 30 compressions/cycle (95%), performed compressions of at least 5 cm depth (89%), released the chest (90%), applied two breaths (97%), used the automated external defibrillator (97%), and positioned the pads (100%). The online course was an effective method for teaching and learning key BLS skills wherein students were able to accurately apply BLS procedures during the CPR simulation. This short-term online training, which likely improves learning and self-efficacy in BLS providers, can be used for the continuing education of health professionals.

  2. Coronary blood flow during cardiopulmonary resuscitation in swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bellamy, R.F.; DeGuzman, L.R.; Pedersen, D.C.

    1984-01-01

    Recent papers have raised doubt as to the magnitude of coronary blood flow during closed-chest cardiopulmonary resuscitation. We will describe experiments that concern the methods of coronary flow measurement during cardiopulmonary resuscitation. Nine anesthetized swine were instrumented to allow simultaneous measurements of coronary blood flow by both electromagnetic cuff flow probes and by the radiomicrosphere technique. Cardiac arrest was caused by electrical fibrillation and closed-chest massage was performed by a Thumper (Dixie Medical Inc., Houston). The chest was compressed transversely at a rate of 66 strokes/min. Compression occupied one-half of the massage cycle. Three different Thumper piston strokes were studied:more » 1.5, 2, and 2.5 inches. Mean aortic pressure and total systemic blood flow measured by the radiomicrosphere technique increased as Thumper piston stroke was lengthened (mean +/- SD): 1.5 inch stroke, 23 +/- 4 mm Hg, 525 +/- 195 ml/min; 2 inch stroke, 33 +/- 5 mm Hg, 692 +/- 202 ml/min; 2.5 inch stroke, 40 +/- 6 mm Hg, 817 +/- 321 ml/min. Both methods of coronary flow measurement (electromagnetic (EMF) and radiomicrosphere (RMS)) gave similar results in technically successful preparations (data expressed as percent prearrest flow mean +/- 1 SD): 1.5 inch stroke, EMF 12 +/- 5%, RMS 16 +/- 5%; 2 inch stroke, EMF 30 +/- 6%, RMS 26 +/- 11%; 2.5 inch stroke, EMF 50 +/- 12%, RMS 40 +/- 20%. The phasic coronary flow signal during closed-chest compression indicated that all perfusion occurred during the relaxation phase of the massage cycle. We concluded that coronary blood flow is demonstrable during closed-chest massage, but that the magnitude is unlikely to be more than a fraction of normal.« less

  3. Traumatic asphyxia.

    PubMed

    Montes-Tapia, Fernando; Barreto-Arroyo, Itzel; Cura-Esquivel, Idalia; Rodríguez-Taméz, Antonio; de la O-Cavazos, Manuel

    2014-02-01

    Traumatic asphyxia is a rare condition in children that usually occurs after severe compression to the chest or abdomen. We report 3 cases in patients 18, 20, and 36 months of age who presented signs and symptoms of traumatic asphyxia after car accidents. Two clinical features were consistent in all 3 patients: multiple petechiae on the face and bulbar conjunctival hemorrhage; 2 patients had facial cyanosis, and 1 had facial edema.In children, the number of clinical manifestations that should be evident to diagnose traumatic asphyxia has not been ascertained. However, in any history of trauma with compression of the chest or abdomen and signs of increased intravenous craniocervical pressure, traumatic asphyxia should be suspected.

  4. Observer performance assessment of JPEG-compressed high-resolution chest images

    NASA Astrophysics Data System (ADS)

    Good, Walter F.; Maitz, Glenn S.; King, Jill L.; Gennari, Rose C.; Gur, David

    1999-05-01

    The JPEG compression algorithm was tested on a set of 529 chest radiographs that had been digitized at a spatial resolution of 100 micrometer and contrast sensitivity of 12 bits. Images were compressed using five fixed 'psychovisual' quantization tables which produced average compression ratios in the range 15:1 to 61:1, and were then printed onto film. Six experienced radiologists read all cases from the laser printed film, in each of the five compressed modes as well as in the non-compressed mode. For comparison purposes, observers also read the same cases with reduced pixel resolutions of 200 micrometer and 400 micrometer. The specific task involved detecting masses, pneumothoraces, interstitial disease, alveolar infiltrates and rib fractures. Over the range of compression ratios tested, for images digitized at 100 micrometer, we were unable to demonstrate any statistically significant decrease (p greater than 0.05) in observer performance as measured by ROC techniques. However, the observers' subjective assessments of image quality did decrease significantly as image resolution was reduced and suggested a decreasing, but nonsignificant, trend as the compression ratio was increased. The seeming discrepancy between our failure to detect a reduction in observer performance, and other published studies, is likely due to: (1) the higher resolution at which we digitized our images; (2) the higher signal-to-noise ratio of our digitized films versus typical CR images; and (3) our particular choice of an optimized quantization scheme.

  5. Layered compression for high-precision depth data.

    PubMed

    Miao, Dan; Fu, Jingjing; Lu, Yan; Li, Shipeng; Chen, Chang Wen

    2015-12-01

    With the development of depth data acquisition technologies, access to high-precision depth with more than 8-b depths has become much easier and determining how to efficiently represent and compress high-precision depth is essential for practical depth storage and transmission systems. In this paper, we propose a layered high-precision depth compression framework based on an 8-b image/video encoder to achieve efficient compression with low complexity. Within this framework, considering the characteristics of the high-precision depth, a depth map is partitioned into two layers: 1) the most significant bits (MSBs) layer and 2) the least significant bits (LSBs) layer. The MSBs layer provides rough depth value distribution, while the LSBs layer records the details of the depth value variation. For the MSBs layer, an error-controllable pixel domain encoding scheme is proposed to exploit the data correlation of the general depth information with sharp edges and to guarantee the data format of LSBs layer is 8 b after taking the quantization error from MSBs layer. For the LSBs layer, standard 8-b image/video codec is leveraged to perform the compression. The experimental results demonstrate that the proposed coding scheme can achieve real-time depth compression with satisfactory reconstruction quality. Moreover, the compressed depth data generated from this scheme can achieve better performance in view synthesis and gesture recognition applications compared with the conventional coding schemes because of the error control algorithm.

  6. Factors affecting measurement of optic parameters by time-resolved near-infrared spectroscopy in breast cancer

    NASA Astrophysics Data System (ADS)

    Yoshizawa, Nobuko; Ueda, Yukio; Mimura, Tetsuya; Ohmae, Etsuko; Yoshimoto, Kenji; Wada, Hiroko; Ogura, Hiroyuki; Sakahara, Harumi

    2018-02-01

    The purpose of this study was to evaluate the effects of the thickness and depth of tumors on hemoglobin measurements in breast cancer by optical spectroscopy and to demonstrate tissue oxygen saturation (SO2) and reduced scattering coefficient (μs‧) in breast tissue and breast cancer in relation to the skin-to-chest wall distance. We examined 53 tumors from 44 patients. Total hemoglobin concentration (tHb), SO2, and μs‧ were measured by time-resolved spectroscopy (TRS). The skin-to-chest wall distance and the size and depth of tumors were measured by ultrasonography. There was a positive correlation between tHb and tumor thickness, and a negative correlation between tHb and tumor depth. SO2 in breast tissue decreased when the skin-to-chest wall distance decreased, and SO2 in tumors tended to be lower than in breast tissue. In breast tissue, there was a negative correlation between μs‧ and the skin-to-chest wall distance, and μs‧ in tumors was higher than in breast tissue. Measurement of tHb in breast cancer by TRS was influenced by tumor thickness and depth. Although SO2 seemed lower and μs‧ was higher in breast cancer than in breast tissue, the skin-to-chest wall distance may have affected the measurements.

  7. Two-Thumb Encircling Technique Over the Head of Patients in the Setting of Lone Rescuer Infant CPR Occurred During Ambulance Transfer: A Crossover Simulation Study.

    PubMed

    Jo, Choong Hyun; Cho, Gyu Chong; Lee, Chang Hee

    2017-07-01

    The purpose of this study was to determine if the over-the-head 2-thumb encircling technique (OTTT) provides better overall quality of cardiopulmonary resuscitation compared with conventional 2-finger technique (TFT) for a lone rescuer in the setting of infant cardiac arrest in ambulance. Fifty medical emergency service students were voluntarily recruited to perform lone rescuer infant cardiopulmonary resuscitation for 2 minutes on a manikin simulating a 3-month-old baby in an ambulance. Participants who performed OTTT sat over the head of manikins to compress the chest using a 2-thumb encircling technique and provide bag-valve mask ventilations, whereas those who performed TFT sat at the side of the manikins to compress using 2-fingers and provide pocket-mask ventilations. Mean hands-off time was not significantly different between OTTT and TFT (7.6 ± 1.1 seconds vs 7.9 ± 1.3 seconds, P = 0.885). Over-the-head 2-thumb encircling technique resulted in greater depth of compression (42.6 ± 1.4 mm vs 41.0 ± 1.4 mm, P < 0.001) and faster rate of compressions (114.4 ± 8.0 per minute vs 112.2 ± 8.2 per minute, P = 0.019) than TFT. Over-the-head 2-thumb encircling technique resulted in a smaller fatigue score than TFT (1.7 ± 1.5 vs 2.5 ± 1.6, P < 0.001). In addition, subjects reported that compression, ventilation, and changing compression to ventilation were easier in OTTT than in TFT. The use of OTTT may be a suitable alternative to TFT in the setting of cardiac arrest of infants during ambulance transfer.

  8. A tourniquet assisted cardiopulmonary resuscitation augments myocardial perfusion in a porcine model of cardiac arrest.

    PubMed

    Yang, Zhengfei; Tang, David; Wu, Xiaobo; Hu, Xianwen; Xu, Jiefeng; Qian, Jie; Yang, Min; Tang, Wanchun

    2015-01-01

    During cardiopulmonary resuscitation (CPR), myocardial blood flow generated by chest compression rarely exceeds 35% of its normal level. Cardiac output generated by chest compression decreases gradually with the prolongation of cardiac arrest and resuscitation. Early studies have demonstrated that myocardial blood flow during CPR is largely dependent on peripheral vascular resistance. In this study, we investigated the effects of chest compression in combination with physical control of peripheral vascular resistance assisted by tourniquets on myocardial blood flow during CPR. Ventricular fibrillation was induced and untreated for 7 min in ten male domestic pigs weighing between 33 and 37 kg. The animals were then randomized to receive CPR alone or a tourniquet assisted CPR (T-CPR). In the CPR alone group, chest compression was performed by a miniaturized mechanical chest compressor. In the T-CPR group, coincident with the start of resuscitation, the thin elastic tourniquets were wrapped around the four limbs from the distal end to the proximal part. After 2 min of CPR, epinephrine (20 μg/kg) was administered via the femoral vein. After 5 min of CPR, defibrillation was attempted by a single 150 J shock. If resuscitation was not successful, CPR was resumed for 2 min before the next defibrillation. The protocol was continued until successful resuscitation or for a total of 15 min. Five minutes after resuscitation, the elastic tourniquets were removed. The resuscitated animals were observed for 2h. T-CPR generated significantly greater coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow. There was no difference in both intrathoracic positive and negative pressures between the two groups. All animals were successfully resuscitated with a single shock in both groups. There were no significant changes in hemodynamics observed in the animals treated in the T-CPR group before-and-after the release of tourniquets at post-resuscitation 5 min. T-CPR improves myocardial and cerebral perfusion during CPR. It may provide a new and convenient method for augmenting myocardial and cerebral blood flow during CPR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Human occupants in low-speed frontal sled tests: effects of pre-impact bracing on chest compression, reaction forces, and subject acceleration.

    PubMed

    Kemper, Andrew R; Beeman, Stephanie M; Madigan, Michael L; Duma, Stefan M

    2014-01-01

    The purpose of this study was to investigate the effects of pre-impact bracing on the chest compression, reaction forces, and accelerations experienced by human occupants during low-speed frontal sled tests. A total of twenty low-speed frontal sled tests, ten low severity (∼2.5g, Δv=5 kph) and ten medium severity (∼5g, Δv=10 kph), were performed on five 50th-percentile male human volunteers. Each volunteer was exposed to two impulses at each severity, one relaxed and the other braced prior to the impulse. A 59-channel chestband, aligned at the nipple line, was used to quantify the chest contour and anterior-posterior sternum deflection. Three-axis accelerometer cubes were attached to the sternum, 7th cervical vertebra, and sacrum of each subject. In addition, three linear accelerometers and a three-axis angular rate sensor were mounted to a metal mouthpiece worn by each subject. Seatbelt tension load cells were attached to the retractor, shoulder, and lap portions of the standard three-point driver-side seatbelt. In addition, multi-axis load cells were mounted to each interface between the subject and the test buck to quantify reaction forces. For relaxed tests, the higher test severity resulted in significantly larger peak values for all resultant accelerations, all belt forces, and three resultant reaction forces (right foot, seatpan, and seatback). For braced tests, the higher test severity resulted in significantly larger peak values for all resultant accelerations, and two resultant reaction forces (right foot and seatpan). Bracing did not have a significant effect on the occupant accelerations during the low severity tests, but did result in a significant decrease in peak resultant sacrum linear acceleration during the medium severity tests. Bracing was also found to significantly reduce peak shoulder and retractor belt forces for both test severities, and peak lap belt force for the medium test severity. In contrast, bracing resulted in a significant increase in the peak resultant reaction force for the right foot and steering column at both test severities. Chest compression due to belt loading was observed for all relaxed subjects at both test severities, and was found to increase significantly with increasing severity. Conversely, chest compression due to belt loading was essentially eliminated during the braced tests for all but one subject, who sustained minor chest compression due to belt loading during the medium severity braced test. Overall, the data from this study illustrate that muscle activation has a significant effect on the biomechanical response of human occupants in low-speed frontal impacts.

  10. High bit depth infrared image compression via low bit depth codecs

    NASA Astrophysics Data System (ADS)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-08-01

    Future infrared remote sensing systems, such as monitoring of the Earth's environment by satellites, infrastructure inspection by unmanned airborne vehicles etc., will require 16 bit depth infrared images to be compressed and stored or transmitted for further analysis. Such systems are equipped with low power embedded platforms where image or video data is compressed by a hardware block called the video processing unit (VPU). However, in many cases using two 8-bit VPUs can provide advantages compared with using higher bit depth image compression directly. We propose to compress 16 bit depth images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed by an image or video codec with 8 bits per pixel input format. We analyze how the compression parameters for both MSB and LSB images should be chosen to provide the maximum objective quality for a given compression ratio. Finally, we apply the proposed infrared image compression method utilizing JPEG and H.264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can achieve similar result as 16 bit HEVC codec.

  11. Very brief training for laypeople in hands-only cardiopulmonary resuscitation. Effect of real-time feedback.

    PubMed

    González-Salvado, Violeta; Fernández-Méndez, Felipe; Barcala-Furelos, Roberto; Peña-Gil, Carlos; González-Juanatey, José Ramón; Rodríguez-Núñez, Antonio

    2016-06-01

    Bystander cardiopulmonary resuscitation (CPR) improves survival from out-of-hospital cardiac arrest, but rates and performance quality remain low. Although training laypeople is a primary educational goal, the optimal strategy is not well defined. This study aimed to determine whether a short training with real-time feedback was able to improve hands-only CPR among untrained citizens. On the occasion of the 2015 World Heart Day and the European Restart a Heart Day, a pilot study involving 155 participants (81 laypeople, 74 health care professionals) was conducted. Participants were invited to briefly practice hands-only CPR on a manikin and were after evaluated during a 2-minute chest compression (CC) test. During training brief instructions regarding hand position, compression rate and depth according to the current guidelines were given and real-time feedback was provided by a Laerdal SkillReporting System. Mean CC rate was significantly higher among health care professionals than among laypeople (119.07 ± 12.85 vs 113.02 ± 13.90 min(-1); P = .006), although both met the 100-120 CC min(-1) criterion. Laypeople achieved noninferior results regarding % of CC at adequate rate (51.46% ± 35.32% vs health care staff (55.97% ± 36.36%; P = .43) and depth (49.88% ± 38.58% vs 50.46% ± 37.17%; P = .92), % of CC with full-chest recoil (92.77% ± 17.17% vs 0.91% ± 18.84; P = .52), and adequate hand position (96.94% ± 14.78% vs 99.74 ± 1.98%; P = .11). The overall quality performance was greater than 70%, noninferior for citizens (81.23% ± 20.10%) vs health care staff (85.95% ± 14.78%; P = .10). With a very brief training supported by hands-on instructor-led advice and visual feedback, naïve laypeople are able to perform good-quality CC-CPR. Simple instructions, feedback, and motivation were the key elements of this strategy, which could make feasible to train big numbers of citizens. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Finite element comparison of human and Hybrid III responses in a frontal impact.

    PubMed

    Danelson, Kerry A; Golman, Adam J; Kemper, Andrew R; Gayzik, F Scott; Clay Gabler, H; Duma, Stefan M; Stitzel, Joel D

    2015-12-01

    The improvement of finite element (FE) Human Body Models (HBMs) has made them valuable tools for investigating restraint interactions compared to anthropomorphic test devices (ATDs). The objective of this study was to evaluate the effect of various combinations of safety restraint systems on the sensitivity of thoracic injury criteria using matched ATD and Human Body Model (HBM) simulations at two crash severities. A total of seven (7) variables were investigated: 3-point belt with two (2) load limits, frontal airbag, knee bolster airbag, a buckle pretensioner, and two (2) delta-v's - 40kph and 50kph. Twenty four (24) simulations were conducted for the Hybrid III ATD FE model and repeated with a validated HBM for 48 total simulations. Metrics tested in these conditions included sternum deflection, chest acceleration, chest excursion, Viscous Criteria (V*C) criteria, pelvis acceleration, pelvis excursion, and femur forces. Additionally, chest band deflection and rib strain distribution were measured in the HBM for additional restraint condition discrimination. The addition of a frontal airbag had the largest effect on the occupant chest metrics with an increase in chest compression and acceleration but a decrease in excursion. While the THUMS and Hybrid III occupants demonstrated the same trend in the chest compression measurements, there were conflicting results in the V*C, acceleration, and displacement metrics. Similarly, the knee bolster airbag had the largest effect on the pelvis with a decrease in acceleration and excursion. With a knee bolster airbag the simulated occupants gave conflicting results, the THUMS had a decrease in femur force and the ATD had an increase. Preferential use of dummies or HBM's is not debated; however, this study highlights the ability of HBM metrics to capture additional chest response metrics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Retention of Cardiopulmonary Resuscitation Skills by Medical Students.

    ERIC Educational Resources Information Center

    Fossel, Michael; And Others

    1983-01-01

    A study of preclinical medical students' cardiopulmonary resuscitation (CPR) skills showed students had a very recent CPR course had a significantly lower failure rate than those with courses one or two years previously. The most frequent errors were in chest compression rate and inability to adhere to the single-rescuer compression-to-ventilation…

  14. A multicenter observer performance study of 3D JPEG2000 compression of thin-slice CT.

    PubMed

    Erickson, Bradley J; Krupinski, Elizabeth; Andriole, Katherine P

    2010-10-01

    The goal of this study was to determine the compression level at which 3D JPEG2000 compression of thin-slice CTs of the chest and abdomen-pelvis becomes visually perceptible. A secondary goal was to determine if residents in training and non-physicians are substantially different from experienced radiologists in their perception of compression-related changes. This study used multidetector computed tomography 3D datasets with 0.625-1-mm thickness slices of standard chest, abdomen, or pelvis, clipped to 12 bits. The Kakadu v5.2 JPEG2000 compression algorithm was used to compress and decompress the 80 examinations creating four sets of images: lossless, 1.5 bpp (8:1), 1 bpp (12:1), and 0.75 bpp (16:1). Two randomly selected slices from each examination were shown to observers using a flicker mode paradigm in which observers rapidly toggled between two images, the original and a compressed version, with the task of deciding whether differences between them could be detected. Six staff radiologists, four residents, and six PhDs experienced in medical imaging (from three institutions) served as observers. Overall, 77.46% of observers detected differences at 8:1, 94.75% at 12:1, and 98.59% at 16:1 compression levels. Across all compression levels, the staff radiologists noted differences 64.70% of the time, the resident's detected differences 71.91% of the time, and the PhDs detected differences 69.95% of the time. Even mild compression is perceptible with current technology. The ability to detect differences does not equate to diagnostic differences, although perception of compression artifacts could affect diagnostic decision making and diagnostic workflow.

  15. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    PubMed Central

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  16. [A brief history of resuscitation - the influence of previous experience on modern techniques and methods].

    PubMed

    Kucmin, Tomasz; Płowaś-Goral, Małgorzata; Nogalski, Adam

    2015-02-01

    Cardiopulmonary resuscitation (CPR) is relatively novel branch of medical science, however first descriptions of mouth-to-mouth ventilation are to be found in the Bible and literature is full of descriptions of different resuscitation methods - from flagellation and ventilation with bellows through hanging the victims upside down and compressing the chest in order to stimulate ventilation to rectal fumigation with tobacco smoke. The modern history of CPR starts with Kouwenhoven et al. who in 1960 published a paper regarding heart massage through chest compressions. Shortly after that in 1961Peter Safar presented a paradigm promoting opening the airway, performing rescue breaths and chest compressions. First CPR guidelines were published in 1966. Since that time guidelines were modified and improved numerously by two leading world expert organizations ERC (European Resuscitation Council) and AHA (American Heart Association) and published in a new version every 5 years. Currently 2010 guidelines should be obliged. In this paper authors made an attempt to present history of development of resuscitation techniques and methods and assess the influence of previous lifesaving methods on nowadays technologies, equipment and guidelines which allow to help those women and men whose life is in danger due to sudden cardiac arrest. © 2015 MEDPRESS.

  17. Learning basic life support (BLS) with tablet PCs in reciprocal learning at school: are videos superior to pictures? A randomized controlled trial.

    PubMed

    Iserbyt, Peter; Charlier, Nathalie; Mols, Liesbet

    2014-06-01

    It is often assumed that animations (i.e., videos) will lead to higher learning compared to static media (i.e., pictures) because they provide a more realistic demonstration of the learning task. To investigate whether learning basic life support (BLS) and cardiopulmonary resuscitation (CPR) from video produce higher learning outcomes compared to pictures in reciprocal learning. A randomized controlled trial. A total of 128 students (mean age: 17 years) constituting eight intact classes from a secondary school learned BLS in reciprocal roles of doer and helper with tablet PCs. Student pairs in each class were randomized over a Picture and a Video group. In the Picture group, students learned BLS by means of pictures combined with written instructions. In the Video group, BLS was learned through videos with on-screen instructions. Informational equivalence was assured since instructions in both groups comprised exactly the same words. BLS assessment occurred unannounced, three weeks following intervention. Analysis of variance demonstrated no significant differences in chest compression depths between the Picture group (M=42 mm, 95% CI=40-45) and the Video group (M=39 mm, 95% CI=36-42). In the Picture group significantly higher percentages of chest compressions with correct hand placement were achieved (M=67%, CI=58-77) compared to the Video group (M=53%, CI=43-63), P=.03, η(p)(2)=.03. No other significant differences were found. Results do not support the assumption that videos are superior to pictures for learning BLS and CPR in reciprocal learning. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. The effects of an online basic life support course on undergraduate nursing students’ learning

    PubMed Central

    Tobase, Lucia; Peres, Heloisa H.C.; Smith, Nicole; Polastri, Thatiane F.; Timerman, Sergio

    2017-01-01

    Objectives To describe learning outcomes of undergraduate nursing students following an online basic life support course (BLS). Methods An online BLS course was developed and administered to 94 nursing students. Pre- and post-tests were used to assess theoretical learning. Checklist simulations and feedback devices were used to assess the cardiopulmonary resuscitation (CPR) skills of the 62 students who completed the course. Results A paired t-test revealed a significant increase in learning [pre-test (6.4 ± 1.61), post-test (9.3 ± 0.82), p < 0.001]. The increase in the average grade after taking the online course was significant (p<0.001). No learning differences (p=0.475) had been observed between 1st and 2nd year (9.20 ± 1.60), and between 3rd and 4th year (9.67 ± 0.61) students. A CPR simulation was performed after completing the course: students checked for a response (90%), exposed the chest (98%), checked for breathing (97%), called emergency services (76%), requested for a defibrillator (92%), checked for a pulse (77%), positioned their hands properly (87%), performed 30 compressions/cycle (95%), performed compressions of at least 5 cm depth (89%), released the chest (90%), applied two breaths (97%), used the automated external defibrillator (97%), and positioned the pads (100%). Conclusions The online course was an effective method for teaching and learning key BLS skills wherein students were able to accurately apply BLS procedures during the CPR simulation. This short-term online training, which likely improves learning and self-efficacy in BLS providers, can be used for the continuing education of health professionals. PMID:28850944

  19. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    PubMed

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  20. Open chest cardiac massage offers no benefit over closed chest compressions in patients with traumatic cardiac arrest.

    PubMed

    Bradley, Matthew J; Bonds, Brandon W; Chang, Luke; Yang, Shiming; Hu, Peter; Li, Hsiao-Chi; Brenner, Megan L; Scalea, Thomas M; Stein, Deborah M

    2016-11-01

    Open chest cardiac massage (OCCM) is a commonly performed procedure after traumatic cardiac arrest (TCA). OCCM has been reported to be superior to closed chest compressions (CCC) in animal models and in non-TCA. The purpose of this study is to prospectively compare OCCM versus CCC in TCA using end-tidal carbon dioxide (ETCO2), the criterion standard for determining the effectiveness of chest compressions and detection of return of spontaneous circulation (ROSC), as the surrogate for cardiac output and marker for adequacy of resuscitation. This prospective observational study enrolled patients over a 9-month period directly presenting to a level 1 trauma center after TCA. Continuous high-resolution ETCO2 measurements were collected every 6 seconds for periods of CCC and OCCM, respectively. Patients receiving CCC only were compared with patients receiving CCC followed by OCCM. Student's t tests were used to compare ETCO2 within and between groups. Thirty-three patients were enrolled (16 OCCM, 17 CCC-only). Mean time of CCC before OCCM was 66 seconds. Within the OCCM group, final, peak, mean, and median ETCO2 levels significantly increased when comparing the initial CCC period to the OCCM interval. Using a time-matched comparison, significant increases were observed in the final and peak but not mean and median values when comparing the first minute of CCC to the remaining time in the CCC-only group. However, when periods of OCCM were compared with equivalent periods of CCC-only, there were no differences in the initial, final, peak, mean, or median ETCO2 values. Correspondingly, no difference in rates of ROSC was observed between groups (OCCM 23.5% vs. CCC 38.9%; p = 0.53). Although we could not control for confounders, we found no significant improvement in ETCO2 or ROSC with OCCM. With newer endovascular techniques for aortic occlusion, thoracotomy solely for performing OCCM provides no benefit over CCC. Therapeutic study, level III.

  1. Chest compression rate feedback based on transthoracic impedance.

    PubMed

    González-Otero, Digna M; Ruiz de Gauna, Sofía; Ruiz, Jesus; Daya, Mohamud R; Wik, Lars; Russell, James K; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso, Erik; Ayala, Unai

    2015-08-01

    Quality of cardiopulmonary resuscitation (CPR) is an important determinant of survival from cardiac arrest. The use of feedback devices is encouraged by current resuscitation guidelines as it helps rescuers to improve quality of CPR performance. To determine the feasibility of a generic algorithm for feedback related to chest compression (CC) rate using the transthoracic impedance (TTI) signal recorded through the defibrillation pads. We analysed 180 episodes collected equally from three different emergency services, each one using a unique defibrillator model. The new algorithm computed the CC-rate every 2s by analysing the TTI signal in the frequency domain. The obtained CC-rate values were compared with the gold standard, computed using the compression force or the ECG and TTI signals when the force was not recorded. The accuracy of the CC-rate, the proportion of alarms of inadequate CC-rate, chest compression fraction (CCF) and the mean CC-rate per episode were calculated. Intervals with CCs were detected with a mean sensitivity and a mean positive predictive value per episode of 96.3% and 97.0%, respectively. Estimated CC-rate had an error below 10% in 95.8% of the time. Mean percentage of accurate alarms per episode was 98.2%. No statistical differences were found between the gold standard and the estimated values for any of the computed metrics. We developed an accurate algorithm to calculate and provide feedback on CC-rate using the TTI signal. This could be integrated into automated external defibrillators and help improve the quality of CPR in basic-life-support settings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Pushing Harder, Pushing Faster, Minimizing Interruptions… But Falling Short of 2010 Cardiopulmonary Resuscitation Targets During In-hospital Pediatric and Adolescent Resuscitation

    PubMed Central

    Sutton, Robert M.; Wolfe, Heather; Nishisaki, Akira; Leffelman, Jessica; Niles, Dana; Meaney, Peter A.; Donoghue, Aaron; Maltese, Matthew R.; Berg, Robert A.; Nadkarni, Vinay M.

    2013-01-01

    Aim The objective of this study was to evaluate the effect of instituting the 2010 Basic Life Support Guidelines on in-hospital pediatric and adolescent cardiopulmonary resuscitation (CPR) quality. We hypothesized that quality would improve, but that targets for chest compression (CC) depth would be difficult to achieve. Methods Prospective in-hospital observational study comparing CPR quality 24 months before and after release of the 2010 Guidelines. CPR recording/feedback-enabled defibrillators collected CPR data (rate (CC/min), depth (mm), CC fraction (CCF, %), leaning (% > 2.5 kg.)). Audiovisual feedback for depth was: 2005 ≥ 38mm; 2010 ≥ 50mm; for rate: 2005 ≥ 90 and ≤ 120 CC/min; 2010 ≥ 100 and ≤ 120 CC/min. The primary outcome was average event depth compared with Student’s t-test. Results 45 CPR events (25 before; 20 after) occurred, resulting in 1336 thirty-second epochs (909 before; 427 after). Compared to 2005, average event depth (50 ± 13 vs. 43 ± 9 mm; p=0.047), rate (113 ± 11 vs. 104 ± 8 CC/min; p<0.01), and CCF (0.94 [0.93, 0.96] vs. 0.9 [0.85, 0.94]; p=0.013) increased during 2010. CPR epochs during the 2010 period more likely to meet Guidelines for CCF (OR 1.7; CI 95: 1.2–2.4; p<0.01), but less likely for rate (OR 0.23; CI 95: 0.12–0.44; p<0.01), and depth (OR 0.31; CI 95: 0.12–0.86; p=0.024). Conclusions Institution of the 2010 Guidelines was associated with increased CC depth, rate, and CC fraction; yet, achieving 2010 targets for rate and depth was difficult. PMID:23954664

  3. Pushing harder, pushing faster, minimizing interruptions… but falling short of 2010 cardiopulmonary resuscitation targets during in-hospital pediatric and adolescent resuscitation.

    PubMed

    Sutton, Robert M; Wolfe, Heather; Nishisaki, Akira; Leffelman, Jessica; Niles, Dana; Meaney, Peter A; Donoghue, Aaron; Maltese, Matthew R; Berg, Robert A; Nadkarni, Vinay M

    2013-12-01

    The objective of this study was to evaluate the effect of instituting the 2010 Basic Life Support Guidelines on in-hospital pediatric and adolescent cardiopulmonary resuscitation (CPR) quality. We hypothesized that quality would improve, but that targets for chest compression (CC) depth would be difficult to achieve. Prospective in-hospital observational study comparing CPR quality 24 months before and after release of the 2010 Guidelines. CPR recording/feedback-enabled defibrillators collected CPR data (rate (CC/min), depth (mm), CC fraction (CCF, %), leaning (%>2.5kg)). Audiovisual feedback for depth was: 2005, ≥38mm; 2010, ≥50mm; for rate: 2005, ≥90 and ≤120CC/min; 2010, ≥100 and ≤120CC/min. The primary outcome was average event depth compared with Student's t-test. 45 CPR events (25 before; 20 after) occurred, resulting in 1336 thirty-second epochs (909 before; 427 after). Compared to 2005, average event depth (50±13mm vs. 43±9mm; p=0.047), rate (113±11CC/min vs. 104±8CC/min; p<0.01), and CCF (0.94 [0.93, 0.96] vs. 0.9 [0.85, 0.94]; p=0.013) increased during 2010. CPR epochs during the 2010 period more likely to meet Guidelines for CCF (OR 1.7; CI95: 1.2-2.4; p<0.01), but less likely for rate (OR 0.23; CI95: 0.12-0.44; p<0.01), and depth (OR 0.31; CI95: 0.12-0.86; p=0.024). Institution of the 2010 Guidelines was associated with increased CC depth, rate, and CC fraction; yet, achieving 2010 targets for rate and depth was difficult. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. Association Between Left Atrial Compression And Atrial Fibrillation: A Case Presentation And A Short Review Of Literature.

    PubMed

    Ahmed, Niloy; Carlos, Morales-Mangual; Moshe, Gunsburg; Yitzhak, Rosen

    2016-01-01

    This case report describes a patient who developed palpitations and chest pain and was found to be in atrial fibrillation, which was likely due to the presence of an extra-cardiac mass. This was compressing the left atrium. The mass was related to small cell carcinoma, which decreased significantly in size after chemotherapy. Resolution of the atrial fibrillation correlated temporally with reduction in the size of the mass and alleviation of the left atrial compression.

  5. Chest compressions in newborn animal models: A review.

    PubMed

    Solevåg, Anne Lee; Cheung, Po-Yin; Lie, Helene; O'Reilly, Megan; Aziz, Khalid; Nakstad, Britt; Schmölzer, Georg Marcus

    2015-11-01

    Much of the knowledge about the optimal way to perform chest compressions (CC) in newborn infants is derived from animal studies. The objective of this review was to identify studies of CC in newborn term animal models and review the evidence. We also provide an overview of the different models. MEDLINE, EMBASE and CINAHL, until September 29th 2014. Study eligibility criteria and interventions: term newborn animal models where CC was performed. Based on 419 retrieved studies from MEDLINE and 502 from EMBASE, 28 studies were included. No additional studies were identified in CINAHL. Most of the studies were performed in pigs after perinatal transition without long-term follow-up. The models differed widely in methodological aspects, which limits the possibility to compare and synthesize findings. Studies uncommonly reported the method for randomization and allocation concealment, and a limited number were blinded. Only the evidence in favour of the two-thumb encircling hands technique for performing CC, a CC to ventilation ratio of 3:1; and that air can be used for ventilation during CC; was supported by more than one study. Animal studies should be performed and reported with the same rigor as in human randomized trials. Good transitional and survival models are needed to further increase the strength of the evidence derived from animal studies of newborn chest compressions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluation of related factors and the outcome in cardiac arrest resuscitation at Thammasat Emergency Department.

    PubMed

    Amnuaypattanapon, Kumpol; Udomsubpayakul, Umaporn

    2010-12-01

    In the present study, we aimed to define the factors contributing to patient survival after treatment by cardiopulmonary resuscitation (CPR) following cardiac arrest. Retrospective analysis was performed on cardiac arrest patients (n=138) who had CPR in the emergency department (ED) at Thammasat University hospital from 2007-2009. Logistic regression was used to analyze factors that related to the sustained return of spontaneous circulation (ROSC) for 20 minutes, survival until discharge, and survival up to 1 month post discharge. The sustained ROSC was 22.5%, survival to discharge 5.6%, and survival from discharge to 1 month 3.6%. Significant factors related to sustained ROSC was the location of cardiac arrest, the cause of arrest, shockable rhythm with defibrillation, the time until chest compression, and CPR duration. The factor influencing survival to discharge was chest compression performed within 15 minutes after cardiac arrest (p = 0.048). No factor however could be attributed to survivability up to 1 month following discharge. Our findings attribute six factors associated to ROSC including the location of arrest, the cause of cardiac arrest, initial cardiac rhythm, shockable rhythm with defibrillation, the time until chest compression and CPR duration. Statistically, resuscitation performed within 15 minutes of cardiac arrest increases the survivability of patients until discharge. However no factors could be related to the percentage of patients surviving up to 1 month post discharge.

  7. CPR - child (1 to 8 years old)

    MedlinePlus

    Rescue breathing and chest compressions - child; Resuscitation - cardiopulmonary - child; Cardiopulmonary resuscitation - child ... take care of children should learn infant and child CPR if they have not already. See www. ...

  8. Kids (learn how to) save lives in the school with the serious game Relive.

    PubMed

    Semeraro, Federico; Frisoli, Antonio; Loconsole, Claudio; Mastronicola, Nicola; Stroppa, Fabio; Ristagno, Giuseppe; Scapigliati, Andrea; Marchetti, Luca; Cerchiari, Erga

    2017-07-01

    Relive is a serious game focusing on increasing kids and young adults' awareness on CPR. We evaluated the use of Relive on schoolchildren. A longitudinal, prospective study was carried out in two high schools in Italy over a 8-month period, divided in three phases: baseline, competition, and retention. Improvement in schoolchildren's CPR awareness, in terms of knowledge (MCQ results) and skills (chest compression (CC) rate and depth), was evaluated. Usability of Relive and differences in CC performance according to sex and BMI class were also evaluated. At baseline, students performed CC with a mean depth of 31mm and a rate of 95 cpm. In the competition phase, students performed CC with a mean depth of 46mm and a rate of 111 cpm. In the retention phase, students performed CC with a mean depth of 47mm and a rate of 131 cpm. Thus, the training session with Relive during the competition phase affected positively both CC depth (p<0.001) and rate (p<0.001). Such an effect persisted up to the retention phase. CC depth was also affected by gender (p<0.01) and BMI class (p<0.01). Indeed, CC depth was significantly greater in male players and in players with higher BMI. Seventy-three percent of students improved their CPR knowledge as represented by an increases in the MCQ score (p<0.001). The participants perceived the Relive to be easy to use with effective feedback. Relive is an useful tool to spread CPR knowledge and improve CPR skills in schoolchildren. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Hemodynamic directed CPR improves short-term survival from asphyxia-associated cardiac arrest.

    PubMed

    Sutton, Robert M; Friess, Stuart H; Bhalala, Utpal; Maltese, Matthew R; Naim, Maryam Y; Bratinov, George; Niles, Dana; Nadkarni, Vinay M; Becker, Lance B; Berg, Robert A

    2013-05-01

    Adequate coronary perfusion pressure (CPP) during cardiopulmonary resuscitation (CPR) is essential for establishing return of spontaneous circulation. The objective of this study was to compare short-term survival using a hemodynamic directed resuscitation strategy versus an absolute depth-guided approach in a porcine model of asphyxia-associated cardiac arrest. We hypothesized that a hemodynamic directed approach would improve short-term survival compared to depth-guided care. After 7 min of asphyxia, followed by induction of ventricular fibrillation, 19 female 3-month old swine (31±0.4 kg) were randomized to receive one of three resuscitation strategies: (1) hemodynamic directed care (CPP-20): chest compressions (CCs) with depth titrated to a target systolic blood pressure of 100 mmHg and titration of vasopressors to maintain CPP>20 mmHg; (2) depth 33 mm (D33): target CC depth of 33 mm with standard American Heart Association (AHA) epinephrine dosing; or (3) depth 51 mm (D51): target CC depth of 51 mm with standard AHA epinephrine dosing. All animals received manual CPR guided by audiovisual feedback for 10 min before first shock. 45-Min survival was higher in the CPP-20 group (6/6) compared to D33 (1/7) or D51 (1/6) groups; p=0.002. Coronary perfusion pressures were higher in the CPP-20 group compared to D33 (p=0.011) and D51 (p=0.04), and in survivors compared to non-survivors (p<0.01). Total number of vasopressor doses administered and defibrillation attempts were not different. Hemodynamic directed care targeting CPPs>20 mmHg improves short-term survival in an intensive care unit porcine model of asphyxia-associated cardiac arrest. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Low-Dose, High-Frequency CPR Training Improves Skill Retention of In-Hospital Pediatric Providers

    PubMed Central

    Niles, Dana; Meaney, Peter A.; Aplenc, Richard; French, Benjamin; Abella, Benjamin S.; Lengetti, Evelyn L.; Berg, Robert A.; Helfaer, Mark A.; Nadkarni, Vinay

    2011-01-01

    OBJECTIVE: To investigate the effectiveness of brief bedside cardiopulmonary resuscitation (CPR) training to improve the skill retention of hospital-based pediatric providers. We hypothesized that a low-dose, high-frequency training program (booster training) would improve CPR skill retention. PATIENTS AND METHODS: CPR recording/feedback defibrillators were used to evaluate CPR quality during simulated arrest. Basic life support–certified, hospital-based providers were randomly assigned to 1 of 4 study arms: (1) instructor-only training; (2) automated defibrillator feedback only; (3) instructor training combined with automated feedback; and (4) control (no structured training). Each session (time: 0, 1, 3, and 6 months after training) consisted of a pretraining evaluation (60 seconds), booster training (120 seconds), and a posttraining evaluation (60 seconds). Excellent CPR was defined as chest compression (CC) depth ≥ one-third anterior-posterior chest depth, rate ≥ 90 and ≤120 CC per minute, ≤20% of CCs with incomplete release (>2500 g), and no flow fraction ≤ 0.30. MEASUREMENTS AND MAIN RESULTS: Eighty-nine providers were randomly assigned; 74 (83%) completed all sessions. Retention of CPR skills was 2.3 times (95% confidence interval [CI]: 1.1–4.5; P = .02) more likely after 2 trainings and 2.9 times (95% CI: 1.4–6.2; P = .005) more likely after 3 trainings. The automated defibrillator feedback only group had lower retention rates compared with the instructor-only training group (odds ratio: 0.41 [95% CI: 0.17–0.97]; P = .043). CONCLUSIONS: Brief bedside booster CPR training improves CPR skill retention. Our data reveal that instructor-led training improves retention compared with automated feedback training alone. Future studies should investigate whether bedside training improves CPR quality during actual pediatric arrests. PMID:21646262

  11. Evaluation of upper body muscle activity during cardiopulmonary resuscitation performance in simulated microgravity

    NASA Astrophysics Data System (ADS)

    Waye, A. B.; Krygiel, R. G.; Susin, T. B.; Baptista, R.; Rehnberg, L.; Heidner, G. S.; de Campos, F.; Falcão, F. P.; Russomano, T.

    2013-09-01

    Performance of efficient single-person cardiopulmonary resuscitation (CPR) is vital to maintain cardiac and cerebral perfusion during the 2-4 min it takes for deployment of advanced life support during a space mission. The aim of the present study was to investigate potential differences in upper body muscle activity during CPR performance at terrestrial gravity (+1Gz) and in simulated microgravity (μG). Muscle activity of the triceps brachii, erector spinae, rectus abdominis and pectoralis major was measured via superficial electromyography in 20 healthy male volunteers. Four sets of 30 external chest compressions (ECCs) were performed on a mannequin. Microgravity was simulated using a body suspension device and harness; the Evetts-Russomano (ER) method was adopted for CPR performance in simulated microgravity. Heart rate and perceived exertion via Borg scores were also measured. While a significantly lower depth of ECCs was observed in simulated microgravity, compared with +1Gz, it was still within the target range of 40-50 mm. There was a 7.7% decrease of the mean (±SEM) ECC depth from 48 ± 0.3 mm at +1Gz, to 44.3 ± 0.5 mm during microgravity simulation (p < 0.001). No significant difference in number or rate of compressions was found between the two conditions. Heart rate displayed a significantly larger increase during CPR in simulated microgravity than at +1Gz, the former presenting a mean (±SEM) of 23.6 ± 2.91 bpm and the latter, 76.6 ± 3.8 bpm (p < 0.001). Borg scores were 70% higher post-microgravity compressions (17 ± 1) than post +1Gz compressions (10 ± 1) (p < 0.001). Intermuscular comparisons showed the triceps brachii to have significantly lower muscle activity than each of the other three tested muscles, in both +1Gz and microgravity. As shown by greater Borg scores and heart rate increases, CPR performance in simulated microgravity is more fatiguing than at +1Gz. Nevertheless, no significant difference in muscle activity between conditions was found, a result that is favourable for astronauts, given the inevitable muscular and cardiovascular deconditioning that occurs during space travel.

  12. Hospital implementation of resuscitation guidelines and review of CPR training programmes: a nationwide study.

    PubMed

    Schmidt, Anders S; Lauridsen, Kasper G; Adelborg, Kasper; Løfgren, Bo

    2016-06-01

    This study aimed to investigate cardiopulmonary resuscitation (CPR) guideline implementation and CPR training in hospitals. This nationwide study included mandatory resuscitation protocols from each Danish hospital. Protocols were systematically reviewed for adherence to the European Resuscitation Council (ERC) 2010 guidelines and CPR training in each hospital. Data were included from 45 of 47 hospitals. Adherence to the ERC basic life support (BLS) algorithm was 49%, whereas 63 and 58% of hospitals adhered to the recommended chest compression depth and rate. Adherence to the ERC advanced life support (ALS) algorithm was 81%. Hospital BLS course duration was [median (interquartile range)] 2.3 (1.5-2.5) h, whereas ALS course duration was 4.0 (2.5-8.0) h. Implementation of ERC 2010 guidelines on BLS is limited in Danish hospitals 2 years after guideline publication, whereas the majority of hospitals adhere to the ALS algorithm. CPR training differs among hospitals.

  13. A comparison between over-the-head and lateral cardiopulmonary resuscitation with a single rescuer by bag-valve mask

    PubMed Central

    Nasiri, Ebrahim; Nasiri, Reza

    2014-01-01

    Context: mask fixation in the lateral position is difficult during CPR. Aim: the aim of this study is to compare the lateral CPR for the use of bag-valve mask by single paramedic rescuer as well as over-the-head CPR on the chest compression and ventilation on the manikin. Settings and Design: Mazandaran University of Medical Sciences. The design of this study was a randomized cross-over trial. Methods: participants learned a standardized theoretical introduction CPR according to the 2010 guidelines. The total number of chest compressions per two minutes was measured. Total number of correct and wrong ventilation per two minutes was evaluated. Statistical Analysis: we used Wilcoxon signed-rank test to analyze the non-normally distributed data in dependence groups A. P-value of more than 0.05 was considered to show statistical significance. Results: there were 100 participants (45 women and 55 men) who participated in the study from September to March, 2011. The compression and ventilation rate in lateral CPR was lower than OTH CPR. Around 51% of participants had correct chest compression rate more than 90 beats per minute in lateral CPR and 65% of them had equal or more than ten correct ventilations per minute. Conclusions: in conclusion, this study confirmed that in a simulated CPR model over-the-head position CPR led to a better BLS than the lateral position CPR by a single paramedic student with a BVM device. We also concluded that by this new BVM fixation method on the face of the patients in the lateral position CPR can be a good alternative over-the-head mask fixation by a single trained rescuer. PMID:24665237

  14. The compressed breast during mammography and breast tomosynthesis: in vivo shape characterization and modeling

    NASA Astrophysics Data System (ADS)

    Rodríguez-Ruiz, Alejandro; Agasthya, Greeshma A.; Sechopoulos, Ioannis

    2017-09-01

    To characterize and develop a patient-based 3D model of the compressed breast undergoing mammography and breast tomosynthesis. During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3D breast surface imaging with structured light (SL) during breast compression, along with simultaneous acquisition of a tomosynthesis image. A pair of SL systems were used to acquire 3D surface images by projecting 24 different patterns onto the compressed breast and capturing their reflection off the breast surface in approximately 12-16 s. The 3D surface was characterized and modeled via principal component analysis. The resulting surface model was combined with a previously developed 2D model of projected compressed breast shapes to generate a full 3D model. Data from ten patients were discarded due to technical problems during image acquisition. The maximum breast thickness (found at the chest-wall) had an average value of 56 mm, and decreased 13% towards the nipple (breast tilt angle of 5.2°). The portion of the breast not in contact with the compression paddle or the support table extended on average 17 mm, 18% of the chest-wall to nipple distance. The outermost point along the breast surface lies below the midline of the total thickness. A complete 3D model of compressed breast shapes was created and implemented as a software application available for download, capable of generating new random realistic 3D shapes of breasts undergoing compression. Accurate characterization and modeling of the breast curvature and shape was achieved and will be used for various image processing and clinical tasks.

  15. Metronome improves compression and ventilation rates during CPR on a manikin in a randomized trial.

    PubMed

    Kern, Karl B; Stickney, Ronald E; Gallison, Leanne; Smith, Robert E

    2010-02-01

    We hypothesized that a unique tock and voice metronome could prevent both suboptimal chest compression rates and hyperventilation. A prospective, randomized, parallel design study involving 34 pairs of paid firefighter/emergency medical technicians (EMTs) performing two-rescuer CPR using a Laerdal SkillReporter Resusci Anne manikin with and without metronome guidance was performed. Each CPR session consisted of 2 min of 30:2 CPR with an unsecured airway, then 4 min of CPR with a secured airway (continuous compressions at 100 min(-1) with 8-10 ventilations/min), repeated after the rescuers switched roles. The metronome provided "tock" prompts for compressions, transition prompts between compressions and ventilations, and a spoken "ventilate" prompt. During CPR with a bag/valve/mask the target compression rate of 90-110 min(-1) was achieved in 5/34 CPR sessions (15%) for the control group and 34/34 sessions (100%) for the metronome group (p<0.001). An excessive ventilation rate was not observed in either the metronome or control group during CPR with a bag/valve/mask. During CPR with a bag/endotracheal tube, the target of both a compression rate of 90-110 min(-1) and a ventilation rate of 8-11 min(-1) was achieved in 3/34 CPR sessions (9%) for the control group and 33/34 sessions (97%) for the metronome group (p<0.001). Metronome use with the secured airway scenario significantly decreased the incidence of over-ventilation (11/34 EMT pairs vs. 0/34 EMT pairs; p<0.001). A unique combination tock and voice prompting metronome was effective at directing correct chest compression and ventilation rates both before and after intubation. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  16. Effects of repetitive or intensified instructions in telephone assisted, bystander cardiopulmonary resuscitation: an investigator-blinded, 4-armed, randomized, factorial simulation trial.

    PubMed

    van Tulder, R; Roth, D; Krammel, M; Laggner, R; Heidinger, B; Kienbacher, C; Novosad, H; Chwojka, C; Havel, C; Sterz, F; Schreiber, W; Herkner, H

    2014-01-01

    Compression depth is frequently suboptimal in cardiopulmonary resuscitation (CPR). We investigated effects of intensified wording and/or repetitive target depth instructions on compression depth in telephone-assisted, protocol driven, bystander CPR on a simulation manikin. Thirty-two volunteers performed 10 min of compression only-CPR in a prospective, investigator-blinded, 4-armed, factorial setting. Participants were randomized either to standard wording ("push down firmly 5 cm"), intensified wording ("it is very important to push down 5 cm every time") or standard or intensified wording repeated every 20s. Three dispatchers were randomized to give these instructions. Primary outcome was relative compression depth (absolute compression depth minus leaning depth). Secondary outcomes were absolute distance, hands-off times as well as BORG-scale and nine-hole peg test (NHPT), pulse rate and blood pressure to reflect physical exertion. We applied a random effects linear regression model. Relative compression depth was 35 ± 10 mm (standard) versus 31 ± 11 mm (intensified wording) versus 25 ± 8 mm (repeated standard) and 31 ± 14 mm (repeated intensified wording). Adjusted for design, body mass index and female sex, intensified wording and repetition led to decreased compression depth of 13 (95%CI -25 to -1) mm (p=0.04) and 9 (95%CI -21 to 3) mm (p=0.13), respectively. Secondary outcomes regarding intensified wording showed significant differences for absolute distance (43 ± 2 versus 20 (95%CI 3-37) mm; p=0.01) and hands-off times (60 ± 40 versus 157 (95%CI 63-251) s; p=0.04). In protocol driven, telephone-assisted, bystander CPR, intensified wording and/or repetitive target depth instruction will not improve compression depth compared to the standard instruction. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. [Randomised study of the relationship between the use of CPRmeter® device and the quality of chest compressions in a simulated cardiopulmonary resuscitation].

    PubMed

    Calvo-Buey, J A; Calvo-Marcos, D; Marcos-Camina, R M

    2016-01-01

    To determine whether the use of CPRmeter(®) during the resuscitation manoeuvres, is related to a higher quality of external cardiac massage, as recommended by the International Liaison Committee on Resuscitation (ILCOR). To compare the quality obtained without the use or this, and whether there are differences related to anthropometric, demographic, professional and/or occupational factors. Experimental, open trial performed with life support simulators in a stratified random sample of 88 health workers randomly distributed between groups A (without indications of the device) and B (with them). The homogeneity of their confounding variables was compared, as well as the compressions depth and compressions rate, the proportion of completed release, and distribution of the quality massage variable (according to criteria ILCOR) between the groups. The qualitative variables were analysed with the chi-square test, and quantitative variables with the Student t-test or Mann-Whitney U-test and the association between the variable quality massage variable, and use of the device with the odds ratio. Group A: mean depth 42.1mm (standard deviation 10.1), mean rate 121.3/min (21.6), percentage of complete release 71.2% (36.9). Group B: 51.2mm (5.9) 111.9/min (6.4), 92.9% (10.1) respectively. Odds ratio for quality massage regarding the use of the device was 5.170 (95% CI; 2.060-12.977). The use of CPRmeter(®) device in simulated resuscitations is related to a higher quality of cardiac massage, improving the approach to the ILCOR recommendations, regardless of the characteristics of the participants. They were 83.8% more likely to achieve a quality massage using the device than without it. Copyright © 2015 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  18. Cardiopulmonary resuscitation quality: [corrected] improving cardiac resuscitation outcomes both inside and outside the hospital: a consensus statement from the American Heart Association.

    PubMed

    Meaney, Peter A; Bobrow, Bentley J; Mancini, Mary E; Christenson, Jim; de Caen, Allan R; Bhanji, Farhan; Abella, Benjamin S; Kleinman, Monica E; Edelson, Dana P; Berg, Robert A; Aufderheide, Tom P; Menon, Venu; Leary, Marion

    2013-07-23

    The "2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care" increased the focus on methods to ensure that high-quality cardiopulmonary resuscitation (CPR) is performed in all resuscitation attempts. There are 5 critical components of high-quality CPR: minimize interruptions in chest compressions, provide compressions of adequate rate and depth, avoid leaning between compressions, and avoid excessive ventilation. Although it is clear that high-quality CPR is the primary component in influencing survival from cardiac arrest, there is considerable variation in monitoring, implementation, and quality improvement. As such, CPR quality varies widely between systems and locations. Victims often do not receive high-quality CPR because of provider ambiguity in prioritization of resuscitative efforts during an arrest. This ambiguity also impedes the development of optimal systems of care to increase survival from cardiac arrest. This consensus statement addresses the following key areas of CPR quality for the trained rescuer: metrics of CPR performance; monitoring, feedback, and integration of the patient's response to CPR; team-level logistics to ensure performance of high-quality CPR; and continuous quality improvement on provider, team, and systems levels. Clear definitions of metrics and methods to consistently deliver and improve the quality of CPR will narrow the gap between resuscitation science and the victims, both in and out of the hospital, and lay the foundation for further improvements in the future.

  19. An ultrasonic measurement for in vitro depth-dependent equilibrium strains of articular cartilage in compression

    NASA Astrophysics Data System (ADS)

    Zheng, Y. P.; Mak, A. F. T.; Lau, K. P.; Qin, L.

    2002-09-01

    The equilibrium depth-dependent biomechanical properties of articular cartilage were measured using an ultrasound-compression method. Ten cylindrical bovine patella cartilage-bone specimens were tested in compression followed by a period of force-relaxation. A 50 MHz focused ultrasound beam was transmitted into the cartilage specimen through a remaining bone layer and a small hole at the centre of a specimen platform. The ultrasound echoes reflected or scattered within the articular cartilage were collected using the same transducer. The displacements of the tissues at different depths of the articular cartilage were derived from the ultrasound echo signals recorded during the compression and the subsequent force-relaxation. For two steps of 0.1 mm compression, the average strain at the superficial 0.2 mm thick layer (0.35 +/- 0.09) was significantly (p < 0.05) larger than that at the subsequent 0.2 mm thick layer (0.05 +/- 0.07) and that at deeper layers (0.01 +/- 0.02). It was demonstrated that the compressive biomechanical properties of cartilage were highly depth-dependent. The results suggested that the ultrasound-compression method could be a useful tool for the study of the depth-dependent biomechanical properties of articular cartilage.

  20. Availability and quality of cardiopulmonary resuscitation information for Spanish-speaking population on the Internet.

    PubMed

    Liu, Kirsten Y; Haukoos, Jason S; Sasson, Comilla

    2014-01-01

    Bystander cardiopulmonary resuscitation (CPR) is a vital link in the chain of survival for out-of-hospital cardiac arrest (OHCA); however, there are racial/ethnic disparities in the provision of bystander CPR. Approximately 32% of Hispanics perform CPR when confronted with cardiac arrest, whereas approximately 41% of non-Hispanics perform CPR. Public education, via the Internet, may be critical in improving the performance of bystander CPR among Hispanics. The objective of this study was to evaluate the availability and quality of CPR-related literature for primary Spanish-speaking individuals on the Internet. Two search engines (Google and Yahoo!) and a video-site (YouTube) were searched using the following terms: "resucitacion cardiopulmonar" and "reanimacion cardiopulmonar." Inclusion criteria were: education of CPR technique. Exclusion criteria were: instruction on pediatric CPR technique, failure to provide any instruction on CPR technique, or duplicated website. Data elements were collected on the content and quality of the websites and videos, such as assessing scene safety, verifying responsiveness, activating EMS, properly positioning hands on chest, performing accurate rate and depth of compressions. Of the 515 websites or videos screened, 116 met criteria for inclusion. The majority of websites (86%; 95% Confidence Interval [CI] 79-92%) educated viewers on traditional bystander CPR (primarily, 30:2 CPR), while only 14% (95% CI 9-21%) taught hands-only CPR. Of websites that used video (N=62), 84% were conducted in Spanish and 16% in English. The quality of CPR education was generally poor (median score of 3/6, IQR of 3.0). Only half of websites properly educated on how to check responsiveness, activate EMS and position hands on chest. Eighty-eight percent of websites failed to educate viewers on assessing scene safety. The majority of websites had improper or no education on both rate and depth of compressions (59% and 63%, respectively). Only 16% of websites included 5 or more quality markers for proper bystander CPR. A small proportion of internet resources have high quality CPR education for a Spanish-speaking population. More emphasis should be placed on improving the quality of educational resources available on the Internet for Spanish-speaking populations, and with particular emphasis on current basic life support recommendations. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Tricuspid valve chordal rupture due to airbag injury and review of pathophysiological mechanisms.

    PubMed

    Thekkudan, Joyce; Luckraz, Heyman; Ng, Alex; Norell, Mike

    2012-09-01

    Blunt trauma to the chest is associated with significant morbidity and mortality. The latter is usually due to an aortic transection, whereas the former is related to myocardial contusion, cardiac valve injury, coronary artery disruption and intracardiac shunts due to the formation of septal defects. The main mechanisms causing these injuries are due to the sudden deceleration force and compression within the chest cavity. Moreover, there is also the sudden increase in intravascular pressure due to a mechanical compression effect and a hormonal adrenergic surge during the event. We report a case of a tricuspid valve injury caused by the deployment of the airbag during a high-speed impact car accident and the subsequent damage to the tricuspid valve chordal mechanism. The patient's management and the pathophysiological mechanisms involved in the injury are reviewed.

  2. Mechanical CPR: Who? When? How?

    PubMed

    Poole, Kurtis; Couper, Keith; Smyth, Michael A; Yeung, Joyce; Perkins, Gavin D

    2018-05-29

    In cardiac arrest, high quality cardiopulmonary resuscitation (CPR) is a key determinant of patient survival. However, delivery of effective chest compressions is often inconsistent, subject to fatigue and practically challenging.Mechanical CPR devices provide an automated way to deliver high-quality CPR. However, large randomised controlled trials of the routine use of mechanical devices in the out-of-hospital setting have found no evidence of improved patient outcome in patients treated with mechanical CPR, compared with manual CPR. The limited data on use during in-hospital cardiac arrest provides preliminary data supporting use of mechanical devices, but this needs to be robustly tested in randomised controlled trials.In situations where high-quality manual chest compressions cannot be safely delivered, the use of a mechanical device may be a reasonable clinical approach. Examples of such situations include ambulance transportation, primary percutaneous coronary intervention, as a bridge to extracorporeal CPR and to facilitate uncontrolled organ donation after circulatory death.The precise time point during a cardiac arrest at which to deploy a mechanical device is uncertain, particularly in patients presenting in a shockable rhythm. The deployment process requires interruptions in chest compression, which may be harmful if the pause is prolonged. It is recommended that use of mechanical devices should occur only in systems where quality assurance mechanisms are in place to monitor and manage pauses associated with deployment.In summary, mechanical CPR devices may provide a useful adjunct to standard treatment in specific situations, but current evidence does not support their routine use.

  3. Junior physician skill and behaviour in resuscitation: a simulation study.

    PubMed

    Høyer, Christian Bjerre; Christensen, Erika F; Eika, Berit

    2009-02-01

    Physicians are expected to manage their role as teamleader during resuscitation. During inter-hospital transfer the physician has the highest medical credentials on a small team. The aim of this study was to describe physician behaviour as teamleaders in a simulated cardiac arrest during inter-hospital transfer. Our goal was to pinpoint deficits in knowledge and skill integration and make recommendations for improvements in education. An ambulance was the framework for the simulation; the scenario a patient with acute coronary syndrome suffering ventricular fibrillation during transportation. Physicians (graduation age < or =5 years) working in internal medicine departments in Denmark were studied. The ambulance crew was instructed to be passive to clarify the behaviour of the physicians. 72 physicians were studied. Chest compressions were initiated in 71 cases, ventilation and defibrillation in 72. The median times for arrival of the driver in the patient cabin, initiation of ventilation and chest compressions, and first defibrillation were all less than 1min. Medication was administered in 63/72 simulations (88%), after a median time of 210 s. Adrenaline was the preferred initial drug administered (58/63, 92%). Tasks delegated were ventilations, chest compressions, defibrillation, and administration of medication (97%, 92%, 42%, and 10% of cases, respectively). Junior physicians performed well with respect to the treatment given and the delegation of tasks. However, variations in the time of initiation it took for each treatment indicated lack of leadership skills. It is imperative that the education of physicians includes training in leadership.

  4. Effect of warm compress application on tissue temperature in healthy dogs.

    PubMed

    Millard, Ralph P; Towle-Millard, Heather A; Rankin, David C; Roush, James K

    2013-03-01

    To measure the effect of warm compress application on tissue temperature in healthy dogs. 10 healthy mixed-breed dogs. Dogs were sedated with hydromorphone (0.1 mg/kg, IV) and diazepam (0.25 mg/kg, IV). Three 24-gauge thermocouple needles were inserted to a depth of 0.5 cm (superficial), 1.0 cm (middle), and 1.5 cm (deep) into a shaved, lumbar, epaxial region to measure tissue temperature. Warm (47°C) compresses were applied with gravity dependence for periods of 5, 10, and 20 minutes. Tissue temperature was recorded before compress application and at intervals for up to 80 minutes after application. Control data were collected while dogs received identical sedation but with no warm compress. Mean temperature associated with 5 minutes of heat application at the superficial, middle, and deep depths was significantly increased, compared with the control temperature. Application for 10 minutes significantly increased the temperature at all depths, compared with 5 minutes of application. Mean temperature associated with 20 minutes of application was not different at the superficial or middle depths, compared with 10 minutes of application. Temperature at the deep depth associated with 10 minutes of application was significantly higher, compared with 20 minutes of application, but all temperature increases at this depth were minimal. Results suggested that application of a warm compress should be performed for 10 minutes. Changes in temperature at a tissue depth of 1.5 cm were minimal or not detected. The optimal compress temperature to achieve therapeutic benefits was not determined.

  5. Capnography and chest wall impedance algorithms for ventilation detection during cardiopulmonary resuscitation

    PubMed Central

    Edelson, Dana P.; Eilevstjønn, Joar; Weidman, Elizabeth K.; Retzer, Elizabeth; Vanden Hoek, Terry L.; Abella, Benjamin S.

    2009-01-01

    Objective Hyperventilation is both common and detrimental during cardiopulmonary resuscitation (CPR). Chest wall impedance algorithms have been developed to detect ventilations during CPR. However, impedance signals are challenged by noise artifact from multiple sources, including chest compressions. Capnography has been proposed as an alternate method to measure ventilations. We sought to assess and compare the adequacy of these two approaches. Methods Continuous chest wall impedance and capnography were recorded during consecutive in-hospital cardiac arrests. Algorithms utilizing each of these data sources were compared to a manually determined “gold standard” reference ventilation rate. In addition, a combination algorithm, which utilized the highest of the impedance or capnography values in any given minute, was similarly evaluated. Results Data were collected from 37 cardiac arrests, yielding 438 min of data with continuous chest compressions and concurrent recording of impedance and capnography. The manually calculated mean ventilation rate was 13.3±4.3/min. In comparison, the defibrillator’s impedance-based algorithm yielded an average rate of 11.3±4.4/min (p=0.0001) while the capnography rate was 11.7±3.7/min (p=0.0009). There was no significant difference in sensitivity and positive predictive value between the two methods. The combination algorithm rate was 12.4±3.5/min (p=0.02), which yielded the highest fraction of minutes with respiratory rates within 2/min of the reference. The impedance signal was uninterpretable 19.5% of the time, compared with 9.7% for capnography. However, the signals were only simultaneously non-interpretable 0.8% of the time. Conclusions Both the impedance and capnography-based algorithms underestimated the ventilation rate. Reliable ventilation rate determination may require a novel combination of multiple algorithms during resuscitation. PMID:20036047

  6. [Basic life support in pediatrics].

    PubMed

    Calvo Macías, A; Manrique Martínez, I; Rodríguez Núñez, A; López-Herce Cid, J

    2006-09-01

    Basic life support (BLS) is the combination of maneuvers that identifies the child in cardiopulmonary arrest and initiates the substitution of respiratory and circulatory function, without the use of technical adjuncts, until the child can receive more advanced treatment. BLS includes a sequence of steps or maneuvers that should be performed sequentially: ensuring the safety of rescuer and child, assessing unconsciousness, calling for help, positioning the victim, opening the airway, assessing breathing, ventilating, assessing signs of circulation and/or central arterial pulse, performing chest compressions, activating the emergency medical service system, and checking the results of resuscitation. The most important changes in the new guidelines are the compression: ventilation ratio and the algorithm for relieving foreign body airway obstruction. A compression/ ventilation ratio of 30:2 will be recommended for lay rescuers of infants, children and adults. Health professionals will use a compression: ventilation ratio of 15:2 for infants and children. If the health professional is alone, he/she may also use a ratio of 30:2 to avoid fatigue. In the algorithm for relieving foreign body airway obstruction, when the child becomes unconscious, the maneuvers will be similar to the BLS sequence with chest compressions (functioning as a deobstruction procedure) and ventilation, with reassessment of the mouth every 2 min to check for a foreign body, and evaluation of breathing and the presence of vital signs. BLS maneuvers are easy to learn and can be performed by anyone with adequate training. Therefore, BLS should be taught to all citizens.

  7. The superiority of the two-thumb over the two-finger technique for single-rescuer infant cardiopulmonary resuscitation.

    PubMed

    Lee, Sang Yoon; Hong, Jun Young; Oh, Je Hyeok; Son, Sun-Han

    2017-03-21

    The two-finger technique (TFT) using the index-middle fingers of the right hand (TFT-R23) was recently confirmed to produce deeper chest compression depth (CCD) compared with the TFT using any other fingers. This study was carried out to confirm whether the TFT-R23 would be as effective as the two-thumb technique (TTT). In addition, individual finger strengths were measured to identify the reasons why the TTT and TFT-R23 produced deeper CCD than any other methods. This prospective randomized cross-over trial compared TTT with TFT-R23. A total of 37 doctors conducted 2 min single-rescuer cardiopulmonary resuscitation using TTT and TFT-R23 in a random order using a 3-month-old sized infant manikin laid on the floor. The chest compression to ventilation ratio was set to 15 : 2. In addition, finger strengths were measured using a pinch meter. The actual CCD of the TTT was significantly deeper than that of the TFT-R23 (41.3±1.3 vs. 39.8±1.5 mm, P<0.001). Although the hands-off time of the TTT was significantly longer than that of the TFT-R23 (55.6±5.7 vs. 53.6±5.8 s, P=0.002), the mean difference was only 2.0±3.7 s (95% confidence interval: 0.755-3.245). The finger strength of the TTT was significantly higher than that of TFT-R23 (23.8±10.1 vs. 13.7±5.1 kg, P<0.001). The TTT produced deeper CCD compared with that of the TFT-R23 because the finger strength of the TTT was significantly higher than that of the TFT-R23.

  8. Neurogenic Thoracic Outlet Syndrome Caused by Vascular Compression of the Brachial Plexus: A Report of Two Cases

    PubMed Central

    Hanna, Amgad; Bodden, Larry O'Neil; Siebiger, Gabriel R. L.

    2018-01-01

    Thoracic outlet syndrome (TOS) is caused by compression of the brachial plexus and/or subclavian vessels as they pass through the cervicothoracobrachial region, exiting the chest. There are three main types of TOS: neurogenic TOS, arterial TOS, and venous TOS. Neurogenic TOS accounts for approximately 95% of all cases, and it is usually caused by physical trauma (posttraumatic etiology), chronic repetitive motion (functional etiology), or bone or muscle anomalies (congenital etiology). We present two cases in which neurogenic TOS was elicited by vascular compression of the inferior portion of the brachial plexus. PMID:29497457

  9. Occupant thorax response variations due to arm position and restraint systems in side impact crash scenarios.

    PubMed

    Gierczycka, Donata; Cronin, Duane S

    2017-09-01

    Recent epidemiological studies have identified that thoracic side airbags may vary in efficacy to reduce injury severity in side impact crash scenarios, while previous experimental and epidemiological studies have presented contrasting results. This study aimed to quantify the variations in occupant response in side impact conditions using a human body computational model integrated with a full vehicle model. The model was analyzed for a Moving Deformable Barrier side impact at 61km/h to assess two pre-crash arm positions, the incorporation of a seatbelt, and a thorax air bag on thorax response. The occupant response was evaluated using chest compression, the viscous criterion and thoracic spinal curvature. The arm position accounted for largest changes in the thorax response (106%) compared to the presence of the airbag and seatbelt systems (75%). It was also noted that the results were dependant on the method and location of thorax response measurement and this should be investigated further. Assessment using lateral displacement of the thoracic spine correlated positively with chest compression and Viscous Criterion, with the benefit of evaluating whole thorax response and provides a useful metric to compare occupant response for different side impact safety systems. The thoracic side airbag was found to increase the chest compression for the driving arm position (+70%), and reduced the injury metrics for the vertical arm position (-17%). This study demonstrated the importance of occupant arm position on variability in thoracic response, and provides insight for future design and optimization of side impact safety systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. An innovative design for cardiopulmonary resuscitation manikins based on a human-like thorax and embedded flow sensors.

    PubMed

    Thielen, Mark; Joshi, Rohan; Delbressine, Frank; Bambang Oetomo, Sidarto; Feijs, Loe

    2017-03-01

    Cardiopulmonary resuscitation manikins are used for training personnel in performing cardiopulmonary resuscitation. State-of-the-art cardiopulmonary resuscitation manikins are still anatomically and physiologically low-fidelity designs. The aim of this research was to design a manikin that offers high anatomical and physiological fidelity and has a cardiac and respiratory system along with integrated flow sensors to monitor cardiac output and air displacement in response to cardiopulmonary resuscitation. This manikin was designed in accordance with anatomical dimensions using a polyoxymethylene rib cage connected to a vertebral column from an anatomical female model. The respiratory system was composed of silicon-coated memory foam mimicking lungs, a polyvinylchloride bronchus and a latex trachea. The cardiovascular system was composed of two sets of latex tubing representing the pulmonary and aortic arteries which were connected to latex balloons mimicking the ventricles and lumped abdominal volumes, respectively. These balloons were filled with Life/form simulation blood and placed inside polyether foam. The respiratory and cardiovascular systems were equipped with flow sensors to gather data in response to chest compressions. Three non-medical professionals performed chest compressions on this manikin yielding data corresponding to force-displacement while the flow sensors provided feedback. The force-displacement tests on this manikin show a desirable nonlinear behaviour mimicking chest compressions during cardiopulmonary resuscitation in humans. In addition, the flow sensors provide valuable data on the internal effects of cardiopulmonary resuscitation. In conclusion, scientifically designed and anatomically high-fidelity designs of cardiopulmonary resuscitation manikins that embed flow sensors can improve physiological fidelity and provide useful feedback data.

  11. Comparison of effectiveness of class lecture versus workshop-based teaching of basic life support on acquiring practice skills among the health care providers

    PubMed Central

    Karim, Habib Md. Reazaul; Yunus, Md.; Bhattacharyya, Prithwis; Ahmed, Ghazal

    2016-01-01

    Background: Basic life support (BLS) is an integral part of emergency medical care. Studies have shown poor knowledge of it among health care providers who are usually taught BLS by lecture-based teachings in classes. Objectives: This study is designed to assess the effectiveness of class lecture versus workshop-based teaching of BLS on acquiring the practice skills on mannequin. Methods: After ethical approval and informed consent from the participants, the present study was conducted among the health care providers. Participants were grouped in lecture-based class teaching and workshop-based teaching. They were then asked to practice BLS on mannequin (Resusci Anne with QCPR) and evaluated as per performance parameters based on American Heart Association BLS. Statistical analyses are done by Fisher's exact t-test using GraphPad INSTAT software and P < 0.05 is taken as significant. Results: There were 55 participants in lecture-based teaching and 50 in workshop-based teaching group. There is no statistical difference in recognition of arrest, checking pulse, and starting chest compression (P > 0.05). Though more than 83% of lecture-based teaching group has started chest compression as compared 96% of workshop group; only 49% of the participants of lecture-based group performed quality chest compression as compared to 82% of other group (P = 0.0005). The workshop group also performed better bag mask ventilation and defibrillation (P < 0.0001). Conclusion: Workshop-based BLS teaching is more effective and lecture-based class teaching better is replaced in medical education curriculum. PMID:27308252

  12. Comparison of effectiveness of class lecture versus workshop-based teaching of basic life support on acquiring practice skills among the health care providers.

    PubMed

    Karim, Habib Md Reazaul; Yunus, Md; Bhattacharyya, Prithwis; Ahmed, Ghazal

    2016-01-01

    Basic life support (BLS) is an integral part of emergency medical care. Studies have shown poor knowledge of it among health care providers who are usually taught BLS by lecture-based teachings in classes. This study is designed to assess the effectiveness of class lecture versus workshop-based teaching of BLS on acquiring the practice skills on mannequin. After ethical approval and informed consent from the participants, the present study was conducted among the health care providers. Participants were grouped in lecture-based class teaching and workshop-based teaching. They were then asked to practice BLS on mannequin (Resusci Anne with QCPR) and evaluated as per performance parameters based on American Heart Association BLS. Statistical analyses are done by Fisher's exact t-test using GraphPad INSTAT software and P < 0.05 is taken as significant. There were 55 participants in lecture-based teaching and 50 in workshop-based teaching group. There is no statistical difference in recognition of arrest, checking pulse, and starting chest compression (P > 0.05). Though more than 83% of lecture-based teaching group has started chest compression as compared 96% of workshop group; only 49% of the participants of lecture-based group performed quality chest compression as compared to 82% of other group (P = 0.0005). The workshop group also performed better bag mask ventilation and defibrillation (P < 0.0001). Workshop-based BLS teaching is more effective and lecture-based class teaching better is replaced in medical education curriculum.

  13. Pediatric Out-of-Hospital Cardiac Arrest Characteristics and Their Association With Survival and Neurobehavioral Outcome.

    PubMed

    Meert, Kathleen L; Telford, Russell; Holubkov, Richard; Slomine, Beth S; Christensen, James R; Dean, J Michael; Moler, Frank W

    2016-12-01

    To investigate relationships between cardiac arrest characteristics and survival and neurobehavioral outcome among children recruited to the Therapeutic Hypothermia after Pediatric Cardiac Arrest Out-of-Hospital trial. Secondary analysis of Therapeutic Hypothermia after Pediatric Cardiac Arrest Out-of-Hospital trial data. Thirty-six PICUs in the United States and Canada. All children (n = 295) had chest compressions for greater than or equal to 2 minutes, were comatose, and required mechanical ventilation after return of circulation. Neurobehavioral function was assessed using the Vineland Adaptive Behavior Scales, Second Edition at baseline (reflecting prearrest status) and 12 months postarrest. U.S. norms for Vineland Adaptive Behavior Scales, Second Edition scores are 100 (mean) ± 15 (SD). Higher scores indicate better functioning. Outcomes included 12-month survival and 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70. Cardiac etiology of arrest, initial arrest rhythm of ventricular fibrillation/tachycardia, shorter duration of chest compressions, compressions not required at hospital arrival, fewer epinephrine doses, and witnessed arrest were associated with greater 12-month survival and 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70. Weekend arrest was associated with lower 12-month survival. Body habitus was associated with 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70; underweight children had better outcomes, and obese children had worse outcomes. On multivariate analysis, acute life threatening event/sudden unexpected infant death, chest compressions more than 30 minutes, and weekend arrest were associated with lower 12-month survival; witnessed arrest was associated with greater 12-month survival. Acute life threatening event/sudden unexpected infant death, other respiratory causes of arrest except drowning, other/unknown causes of arrest, and compressions more than 30 minutes were associated with lower 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70. Many factors are associated with survival and neurobehavioral outcome among children who are comatose and require mechanical ventilation after out-of-hospital cardiac arrest. These factors may be useful for identifying children at risk for poor outcomes, and for improving prevention and resuscitation strategies.

  14. First North American 50 cc Total Artificial Heart Experience: Conversion from a 70 cc Total Artificial Heart.

    PubMed

    Khalpey, Zain; Kazui, Toshinobu; Ferng, Alice S; Connell, Alana; Tran, Phat L; Meyer, Mark; Rawashdeh, Badi; Smith, Richard G; Sweitzer, Nancy K; Friedman, Mark; Lick, Scott; Slepian, Marvin J; Copeland, Jack G

    2016-01-01

    The 70 cc total artificial heart (TAH) has been utilized as bridge to transplant (BTT) for biventricular failure. However, the utilization of 70 cc TAH has been limited to large patients for the low output from the pulmonary as well as systemic vein compression after chest closure. Therefore, the 50 cc TAH was developed by SynCardia (Tucson, AZ) to accommodate smaller chest cavity. We report the first TAH exchange from a 70 to 50 cc due to a fit difficulty. The patient failed to be closed with a 70 cc TAH, although the patient met the conventional 70 cc TAH fit criteria. We successfully closed the chest with a 50 cc TAH.

  15. Eccentric mastectomy and zigzag periareolar incision for gynecomastia.

    PubMed

    Tu, Lung-Chen; Tung, Kwang-Yi; Chen, Heng-Chang; Huang, Wen-Chen; Hsiao, Hung-Tao

    2009-07-01

    Gynecomastia is enlargement of the male breast caused by gland proliferation. Surgery is performed for symptom relief or for cosmetic reasons. The authors used a modified operative procedure, then evaluated the results and safety. Between 2001 and 2005, 22 men (median age, 26 years; range, 13-63 years) with gynecomastia underwent surgery. The operative procedure included a zigzag periareolar skin incision, eccentric subcutaneous mastectomy, and liposuction, with postoperative compression. All the patients were satisfied with the results of the surgery, which produced a chest contour resembling a normal male chest rather than simply a smaller breast. The only complication was a hematoma. One patient was found to have breast cancer. The normal male chest contour can be restored by the described method of eccentric subcutaneous mastectomy.

  16. Comparison of continuous compression with regular ventilations versus 30:2 compressions-ventilations strategy during mechanical cardiopulmonary resuscitation in a porcine model of cardiac arrest.

    PubMed

    Yang, Zhengfei; Liu, Qingyu; Zheng, Guanghui; Liu, Zhifeng; Jiang, Longyuan; Lin, Qing; Chen, Rui; Tang, Wanchun

    2017-09-01

    A compression-ventilation (C:V) ratio of 30:2 is recommended for adult cardiopulmonary resuscitation (CPR) by the current American Heart Association (AHA) guidelines. However, continuous chest compression (CCC) is an alternative strategy for CPR that minimizes interruption especially when an advanced airway exists. In this study, we investigated the effects of 30:2 mechanical CPR when compared with CCC in combination with regular ventilation in a porcine model. Sixteen male domestic pigs weighing 39±2 kg were utilized. Ventricular fibrillation was induced and untreated for 7 min. The animals were then randomly assigned to receive CCC combined with regular ventilation (CCC group) or 30:2 CPR (VC group). Mechanical chest compression was implemented with a miniaturized mechanical chest compressor. At the same time of beginning of precordial compression, the animals were mechanically ventilated at a rate of 10 breaths-per-minute in the CCC group or with a 30:2 C:V ratio in the VC group. Defibrillation was delivered by a single 150 J shock after 5 min of CPR. If failed to resuscitation, CPR was resumed for 2 min before the next shock. The protocol was stopped if successful resuscitation or at a total of 15 min. The resuscitated animals were observed for 72 h. Coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow in the VC group were similar to those achieved in the CCC group during CPR. No significant differences were observed in arterial blood gas parameters between two groups at baseline, VF 6 min, CPR 4 min and 30, 120 and 360 min post-resuscitation. Although extravascular lung water index of both groups significantly increased after resuscitation, no distinct difference was found between CCC and VC groups. All animals were successfully resuscitated and survived for 72 h with favorable neurologic outcomes in both groups. However, obviously more numbers of rib fracture were observed in CCC animals in comparison with VC animals. There was no difference in hemodynamic efficacy and gas exchange during and after resuscitation, therefore identical 72 h survival with intact neurologic function was observed in both VC and CCC groups. However, the incidence of rib fracture increases during the mechanical CPR strategy of CCC combined with regular ventilations.

  17. Convolution neural-network-based detection of lung structures

    NASA Astrophysics Data System (ADS)

    Hasegawa, Akira; Lo, Shih-Chung B.; Freedman, Matthew T.; Mun, Seong K.

    1994-05-01

    Chest radiography is one of the most primary and widely used techniques in diagnostic imaging. Nowadays with the advent of digital radiology, the digital medical image processing techniques for digital chest radiographs have attracted considerable attention, and several studies on the computer-aided diagnosis (CADx) as well as on the conventional image processing techniques for chest radiographs have been reported. In the automatic diagnostic process for chest radiographs, it is important to outline the areas of the lungs, the heart, and the diaphragm. This is because the original chest radiograph is composed of important anatomic structures and, without knowing exact positions of the organs, the automatic diagnosis may result in unexpected detections. The automatic extraction of an anatomical structure from digital chest radiographs can be a useful tool for (1) the evaluation of heart size, (2) automatic detection of interstitial lung diseases, (3) automatic detection of lung nodules, and (4) data compression, etc. Based on the clearly defined boundaries of heart area, rib spaces, rib positions, and rib cage extracted, one should be able to use this information to facilitate the tasks of the CADx on chest radiographs. In this paper, we present an automatic scheme for the detection of lung field from chest radiographs by using a shift-invariant convolution neural network. A novel algorithm for smoothing boundaries of lungs is also presented.

  18. Electrophysiology of Muscle Fatigue in Cardiopulmonary Resuscitation on Manikin Model.

    PubMed

    Cobo-Vázquez, Carlos; De Blas, Gemma; García-Canas, Pablo; Del Carmen Gasco-García, María

    2018-01-01

    Cardiopulmonary resuscitation requires the provider to adopt positions that could be dangerous for his or her spine, specifically affecting the muscles and ligaments in the lumbar zone and the scapular spinal muscles. Increased fatigue caused by muscular activity during the resuscitation could produce a loss of quality and efficacy, resulting in compromising resuscitation. The aim of this study was to evaluate the maximum time a rescuer can perform uninterrupted chest compressions correctly without muscle fatigue. This pilot study was performed at Universidad Complutense de Madrid (Spain) with the population recruited following CONSORT 2010 guidelines. From the 25 volunteers, a total of 14 students were excluded because of kyphoscoliosis (4), lumbar muscle pain (1), anti-inflammatory treatment (3), or not reaching 80% of effective chest compressions during the test (6). Muscle activity at the high spinal and lumbar (L5) muscles was assessed using electromyography while students performed continuous chest compressions on a ResusciAnne manikin. The data from force exerted were analyzed according to side and muscle groups using Student's t test for paired samples. The influence of time, muscle group, and side was analyzed by multivariate analyses ( p ≤ .05). At 2 minutes, high spinal muscle activity (right: 50.82 ± 9.95; left: 57.27 ± 20.85 μV/ms) reached the highest values. Activity decreased at 5 and 15 minutes. At 2 minutes, L5 activity (right: 45.82 ± 9.09; left: 48.91 ± 10.02 μV/ms) reached the highest values. After 5 minutes and at 15 minutes, activity decreased. Fatigue occurred bilaterally and time was the most important factor. Fatigue began at 2 minutes. Rescuers exert muscular countervailing forces in order to maintain effective compressions. This imbalance of forces could determine the onset of poor posture, musculoskeletal pain, and long-term injuries in the rescuer.

  19. Chest compression during sustained inflation versus 3:1 chest compression:ventilation ratio during neonatal cardiopulmonary resuscitation: a randomised feasibility trial.

    PubMed

    Schmölzer, Georg M; O Reilly, Megan; Fray, Caroline; van Os, Sylvia; Cheung, Po-Yin

    2017-10-07

    Current neonatal resuscitation guidelines recommend 3:1 compression:ventilation (C:V) ratio. Recently, animal studies reported that continuous chest compressions (CC) during a sustained inflation (SI) significantly improved return of spontaneous circulation (ROSC). The approach of CC during SI (CC+SI) has not been examined in the delivery room during neonatal resuscitation. It is a feasibility study to compare CC+SI versus 3:1 C:V ratio during neonatal resuscitation in the delivery room. We hypothesised that during neonatal resuscitation, CC+SI will reduce the time to ROSC. Our aim was to examine if CC+SI reduces ROSC compared with 3:1 C:V CPR in preterm infants <33 weeks of gestation. Randomised feasibility trial. Once CC was indicated all eligible infants were immediately and randomly allocated to either CC+SI group or 3:1 C:V group. A sequentially numbered, brown, sealed envelope contained a folded card box with the treatment allocation was opened by the clinical team at the start of CC. Infants in the CC+SI group received CC at a rate of 90/min during an SI with a duration of 20 s (CC+SI). After 20 s, the SI was interrupted for 1 s and the next SI was started for another 20 s until ROSC. Infants in the '3:1 group' received CC using 3:1 C:V ratio until ROSC. Overall the mean (SD) time to ROSC was significantly shorter in the CC+SI group with 31 (9) s compared with 138 (72) s in the 3:1 C:V group (p=0.011). CC+SI is feasible in the delivery room. Clinicaltrials.gov NCT02083705, pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Evaluation of the Boussignac Cardiac arrest device (B-card) during cardiopulmonary resuscitation in an animal model.

    PubMed

    Moore, Johanna C; Lamhaut, Lionel; Hutin, Alice; Dodd, Kenneth W; Robinson, Aaron E; Lick, Michael C; Salverda, Bayert J; Hinke, Mason B; Labarere, José; Debaty, Guillaume; Segal, Nicolas

    2017-10-01

    The purpose of this study was to examine continuous oxygen insufflation (COI) in a swine model of cardiac arrest. The primary hypothesis was COI during standard CPR (S-CPR) should result in higher intrathoracic pressure (ITP) during chest compression and lower ITP during decompression versus S-CPR alone. These changes with COI were hypothesized to improve hemodynamics. The second hypothesis was that changes in ITP with S-CPR+COI would result in superior hemodynamics compared with active compression decompression (ACD) + impedance threshold device (ITD) CPR, as this method primarily lowers ITP during chest decompression. After 6min of untreated ventricular fibrillation, S-CPR was initiated in 8 female swine for 4min, then 3min of S-CPR+COI, then 3min of ACD+ITD CPR, then 3min of S-CPR+COI. ITP and hemodynamics were continuously monitored. During S-CPR+COI, ITP was always positive during the CPR compression and decompression phases. ITP compression values with S-CPR+COI versus S-CPR alone were 5.5±3 versus 0.2±2 (p<0.001) and decompression values were 2.8±2 versus -1.3±2 (p<0.001), respectively. With S-CPR+COI versus ACD+ITD the ITP compression values were 5.5±3 versus 1.5±2 (p<0.01) and decompression values were 2.8±2 versus -4.7±3 (p<0.001), respectively. COI during S-CPR created a continuous positive pressure in the airway during both the compression and decompression phase of CPR. At no point in time did COI generate a negative intrathoracic pressures during CPR in this swine model of cardiac arrest. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The design of instructional tools affects secondary school students' learning of cardiopulmonary resuscitation (CPR) in reciprocal peer learning: a randomized controlled trial.

    PubMed

    Iserbyt, Peter; Byra, Mark

    2013-11-01

    Research investigating design effects of instructional tools for learning Basic Life Support (BLS) is almost non-existent. To demonstrate the design of instructional tools matter. The effect of spatial contiguity, a design principle stating that people learn more deeply when words and corresponding pictures are placed close (i.e., integrated) rather than far from each other on a page was investigated on task cards for learning Cardiopulmonary Resuscitation (CPR) during reciprocal peer learning. A randomized controlled trial. A total of 111 students (mean age: 13 years) constituting six intact classes learned BLS through reciprocal learning with task cards. Task cards combine a picture of the skill with written instructions about how to perform it. In each class, students were randomly assigned to the experimental group or the control. In the control, written instructions were placed under the picture on the task cards. In the experimental group, written instructions were placed close to the corresponding part of the picture on the task cards reflecting application of the spatial contiguity principle. One-way analysis of variance found significantly better performances in the experimental group for ventilation volumes (P=.03, ηp2=.10) and flow rates (P=.02, ηp2=.10). For chest compression depth, compression frequency, compressions with correct hand placement, and duty cycles no significant differences were found. This study shows that the design of instructional tools (i.e., task cards) affects student learning. Research-based design of learning tools can enhance BLS and CPR education. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Traumatic asphyxia due to blunt chest trauma: a case report and literature review

    PubMed Central

    2012-01-01

    Introduction Crush asphyxia is different from positional asphyxia, as respiratory compromise in the latter is caused by splinting of the chest and/or diaphragm, thus preventing normal chest expansion. There are only a few cases or small case series of crush asphyxia in the literature, reporting usually poor outcomes. Case presentation We present the case of a 44-year-old Caucasian man who developed traumatic asphyxia with severe thoracic injury and mild brain edema after being crushed under heavy auto vehicle mechanical parts. He remained unconscious for an unknown time. The treatment included oropharyngeal intubation and mechanical ventilation, bilateral chest tube thoracostomies, treatment of brain edema and other supportive measures. Our patient’s outcome was good. Traumatic asphyxia is generally under-reported and most authors apply supportive measures, while the final outcome seems to be dependent on the length of time of the chest compression and on the associated injuries. Conclusion Treatment for traumatic asphyxia is mainly supportive with special attention to the re-establishment of adequate oxygenation and perfusion; treatment of the concomitant injuries might also affect the final outcome. PMID:22935547

  3. Aspergillus epidural abscess and cord compression in a patient with aspergilloma and empyema. Survival and response to high dose systemic amphotericin therapy.

    PubMed

    Hendrix, W C; Arruda, L K; Platts-Mills, T A; Haworth, C S; Jabour, R; Ward, G W

    1992-06-01

    A 57-yr-old man with a chronic lung cavity presumed to be related to ankylosing spondylitis and/or old cavitary tuberculosis presented with hemoptysis and rapidly developed lower extremity paresis and hypoesthesia. On chest radiograph he had a left upper lobe lesion suggestive of aspergilloma combined with a large left empyema with bronchopleural fistula. Serologic analysis demonstrated precipitins and very high titer IgG antibodies to Aspergillus fumigatus antigens. Decompressive laminectomy from T1 to T5 was performed, with drainage of A. fumigatus culture-positive material from an epidural abscess compressing the spinal cord. Chest drainage was required for control of the empyema. With a total course of 3 g of intravenously administered amphotericin B, rehabilitative therapy, and chronic empyema drainage, he is now at home and ambulatory with assistance. He is also being followed by regular serum assays of IgG antibodies to Aspergillus proteins. We report the case of an apparent long-term survivor of a formerly lethal and/or nonreversible paraplegic condition. The critical factors compared with previous cases with a poor outcome would appear to be prompt neurosurgical intervention, restoration of a normal number of T-cells, effective long-term chest drainage, and high dose amphotericin treatment.

  4. A traumatic asphyxia in a child.

    PubMed

    Nishiyama, T; Hanaoka, K

    2000-11-01

    Traumatic asphyxia in a child is rare and the pathophysiology is different from that occurring in an adult. We report a case of traumatic asphyxia in a child who recovered without specific treatment, even though chest and abdominal compression was severe. A three-year-old boy (14.2 kg) was run over by the rear wheel of a Jeep. He was under the tire for about three minutes and then was transferred to our hospital. When he arrived, he was lethargic with Glasgow Coma Scale of E3V4M6 (coma score of 13). He was cyanotic in his face and had a tire mark from the left shoulder to the right abdomen, petechiae on the head, face, conjunctiva and chest, oral bleeding, and facial edema. Serum concentrations of liver enzymes were increased and microhematuria was detected. However, no injuries were seen in the brain, eye, chest, or abdomen. Cyanosis disappeared in a few hours. Facial and thoracic petechiae disappeared in three days and that of the conjunctiva in five days. He was discharged from hospital on the 13th day without any disturbances. We present a three-year-old boy with traumatic asphyxia. He had no complications although he received severe thoraco-abdominal compression by a Jeep.

  5. 9 Closed chest compressions reduce survival in a model of haemorrhage-induced traumatic cardiac arrest.

    PubMed

    Watts, Sarah; Smith, Jason; Gwyther, Robert; Kirkman, Emrys

    2017-12-01

    Closed chest compressions (CCC) are a key component of resuscitation from medical causes of cardiac arrest, but when haemorrhage, the leading cause of preventable battlefield deaths, is the likely cause there is little evidence to support their use. Resuscitation protocols for traumatic cardiac arrest (TCA) highlight the importance of addressing reversible causes, such as the administration of fluids to treat hypovolaemia. This study evaluated whether CCC were beneficial following haemorrhage-induced TCA and additionally whether resuscitation with blood improved physiological outcomes. The study was conducted with the authority of UK Animals (Scientific Procedures) Act 1986 using 39 terminally anesthetised Large White pigs (35 kg, 29-40 kg) instrumented for invasive physiological monitoring. Following instrumentation and baseline measurements, animals underwent tissue injury (captive bolt to the right thigh) and controlled haemorrhage (30% blood volume). Mean arterial blood pressure (MAP) was maintained at 45 mmHg for 60 min, followed by a further controlled haemorrhage to a MAP of 20 mmHg. As arterial blood and pulse pressures spontaneously deteriorated further over a 5 min period, the randomised resuscitation protocol was initiated as follows: CCC (n=6); IV 0.9% saline (Sal n=8); IV autologous whole blood (WB n=8); IV saline +chest compressions (Sal +CCC n=9); and IV whole blood +chest compressions (WB +CCC n=8). 3×10 ml/kg fluid boluses were administered using the Belmont Rapid Infuser (200 ml/min). CCC were performed using the LUCAS II Chest Compression System.Outcome was attainment of return of spontaneous circulation (ROSC) 15 min post-resuscitation. ROSC was categorised by MAP (MAP ≥50 mmHg=ROSC; MAP >20 <50 mmHg=partial ROSC; MAP ≤20 mmHg=dead).emermed;34/12/A866-a/F1F1F1Figure 1 RESULTS: Outcome was significantly worse in the group that received CCC compared to WB and Sal groups (6/6 dead versus 0/8 and 0/8 respectively) (p<0.0001).A significantly higher number of animals attained ROSC in WB compared to Sal group (6/8 versus 0/8 ROSC and 2/8 versus 8/8 partial ROSC respectively) (p=0.0069).There were some none significant differences between WB and WB+CCC groups (6/8 versus 5/8 ROSC, 2/8 versus 1/8 partial ROSC and 0/8 versus 2/8 dead respectively) (p=0.4411).No animals attained ROSC in the Sal and Sal+CCC groups however significantly more animals died in the Sal+CCC group (0/8 versus 0/9 ROSC, 8/8 versus 2/9 partial ROSC and 0/8 versus 7/9 dead respectively) (p=0.0023). CCC were associated with increased mortality compared to intravenous fluid resuscitation. Resuscitation with whole blood demonstrated the greatest physiological benefit as demonstrated by highest numbers of animals achieving ROSC. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Predefined Redundant Dictionary for Effective Depth Maps Representation

    NASA Astrophysics Data System (ADS)

    Sebai, Dorsaf; Chaieb, Faten; Ghorbel, Faouzi

    2016-01-01

    The multi-view video plus depth (MVD) video format consists of two components: texture and depth map, where a combination of these components enables a receiver to generate arbitrary virtual views. However, MVD presents a very voluminous video format that requires a compression process for storage and especially for transmission. Conventional codecs are perfectly efficient for texture images compression but not for intrinsic depth maps properties. Depth images indeed are characterized by areas of smoothly varying grey levels separated by sharp discontinuities at the position of object boundaries. Preserving these characteristics is important to enable high quality view synthesis at the receiver side. In this paper, sparse representation of depth maps is discussed. It is shown that a significant gain in sparsity is achieved when particular mixed dictionaries are used for approximating these types of images with greedy selection strategies. Experiments are conducted to confirm the effectiveness at producing sparse representations, and competitiveness, with respect to candidate state-of-art dictionaries. Finally, the resulting method is shown to be effective for depth maps compression and represents an advantage over the ongoing 3D high efficiency video coding compression standard, particularly at medium and high bitrates.

  7. Acute ECG changes and chest pain induced by neck motion in patients with cervical hernia--a case report.

    PubMed

    Güler, N; Bilge, M; Eryonucu, B; Cirak, B

    2000-10-01

    We report two cases of acute cervical angina and ECG changes induced by anteflexion of the head. Cervical angina is defined as chest pain that resembles true cardiac angina but originates from cervical discopathy with nerve root compression. In these patients, Prinzmetal's angina, valvular heart disease, congenital heart disease, left ventricular aneurysm, and cardiomyopathy were excluded. After all, the patient's chest pain was reproduced by anteflexion of head, at this time, their ECGs showed nonspecific ST-T changes in the inferior and anterior leads different from the basal ECG. ECG changes returned to normal when the patient's neck moved to the neutral position. To our knowledge, these are the first cases of cervical angina associated with acute ECG changes by neck motion.

  8. Aging and compressibility of municipal solid wastes.

    PubMed

    Chen, Y M; Zhan, Tony L T; Wei, H Y; Ke, H

    2009-01-01

    The expansion of a municipal solid waste (MSW) landfill requires the ability to predict settlement behavior of the existing landfill. The practice of using a single compressibility value when performing a settlement analysis may lead to inaccurate predictions. This paper gives consideration to changes in the mechanical compressibility of MSW as a function of the fill age of MSW as well as the embedding depth of MSW. Borehole samples representative of various fill ages were obtained from five boreholes drilled to the bottom of the Qizhishan landfill in Suzhou, China. Thirty-one borehole samples were used to perform confined compression tests. Waste composition and volume-mass properties (i.e., unit weight, void ratio, and water content) were measured on all the samples. The test results showed that the compressible components of the MSW (i.e., organics, plastics, paper, wood and textiles) decreased with an increase in the fill age. The in situ void ratio of the MSW was shown to decrease with depth into the landfill. The compression index, Cc, was observed to decrease from 1.0 to 0.3 with depth into the landfill. Settlement analyses were performed on the existing landfill, demonstrating that the variation of MSW compressibility with fill age or depth should be taken into account in the settlement prediction.

  9. Image splitting and remapping method for radiological image compression

    NASA Astrophysics Data System (ADS)

    Lo, Shih-Chung B.; Shen, Ellen L.; Mun, Seong K.

    1990-07-01

    A new decomposition method using image splitting and gray-level remapping has been proposed for image compression, particularly for images with high contrast resolution. The effects of this method are especially evident in our radiological image compression study. In our experiments, we tested the impact of this decomposition method on image compression by employing it with two coding techniques on a set of clinically used CT images and several laser film digitized chest radiographs. One of the compression techniques used was full-frame bit-allocation in the discrete cosine transform domain, which has been proven to be an effective technique for radiological image compression. The other compression technique used was vector quantization with pruned tree-structured encoding, which through recent research has also been found to produce a low mean-square-error and a high compression ratio. The parameters we used in this study were mean-square-error and the bit rate required for the compressed file. In addition to these parameters, the difference between the original and reconstructed images will be presented so that the specific artifacts generated by both techniques can be discerned by visual perception.

  10. Anthropomorphic breast phantoms for preclinical imaging evaluation with transmission or emission imaging

    NASA Astrophysics Data System (ADS)

    Tornai, Martin P.; McKinley, Randolph L.; Bryzmialkiewicz, Caryl N.; Cutler, Spencer J.; Crotty, Dominic J.

    2005-04-01

    With the development of several classes of dedicated emission and transmission imaging technologies utilizing ionizing radiation for improved breast cancer detection and in vivo characterization, it is extremely useful to have available anthropomorphic breast phantoms in a variety of shapes, sizes and malleability prior to clinical imaging. These anthropomorphic phantoms can be used to evaluate the implemented imaging approaches given a known quantity, the phantom, and to evaluate the variability of the measurement due to the imaging system chain. Thus, we have developed a set of fillable and incompressible breast phantoms ranging in volume from 240 to 1730mL with nipple-to-chest distances from 3.8 to 12cm. These phantoms are mountable and exchangeable on either a uniform chest plate or anthropomorphic torso phantom containing tissue equivalent bones and surface tissue. Another fillable ~700mL breast phantom with solid anterior chest plate is intentionally compressible, and can be used for direct comparisons between standard planar imaging approaches using mild-to-severe compression, partially compressed tomosynthesis, and uncompressed computed mammotomography applications. These phantoms can be filled with various fluids (water and oil based liquids) to vary the fatty tissue background composition. Shaped cellulose sponges with two cell densities are fabricated and can be added to the breasts to simulate connective tissue. Additionally, microcalcifications can be simulated by peppering slits in the sponges with oyster shell fragments. These phantoms have a utility in helping to evaluate clinical imaging paradigms with known input object parameters using basic imaging characterization, in an effort to further evaluate contemporary and next generation imaging tools. They may additionally provide a means to collect known data samples for task based optimization studies.

  11. Video laryngoscopy vs. direct laryngoscopy: Which should be chosen for endotracheal intubation during cardiopulmonary resuscitation? A prospective randomized controlled study of experienced intubators.

    PubMed

    Kim, Jong Won; Park, Sang O; Lee, Kyeong Ryong; Hong, Dae Young; Baek, Kwang Je; Lee, Young Hwan; Lee, Jeong Hun; Choi, Pil Cho

    2016-08-01

    This study compared endotracheal intubation (ETI) performance during cardiopulmonary resuscitation (CPR) between direct laryngoscopy (DL) and video laryngoscopy (VL) (GlideScope(®)) by experienced intubators (>50 successful ETIs). This was a prospective randomized controlled study conducted in an emergency department between 2011 and 2013. Intubators who used DL or VL were randomly allocated to ETI during CPR. Data were collected from recorded video clips and rhythm sheets. The success, speed, complications, and chest compressions interruption were compared between the two devices. Total 140 ETIs by experienced intubators using DL (n=69) and VL (n=71) were analysed. There were no significant differences between DL and VL in the ETI success rate (92.8% vs. 95.8%; p=0.490), first-attempt success rate (87.0% vs. 94.4%; p=0.204), and median time to complete ETI (51 [36-67] vs. 42 [34-62]s; p=0.143). In both groups, oesophageal intubation and dental injuries seldom occurred. However, longer chest compressions interruption occurred using DL (4.0 [1.0-11.0]s) compared with VL (0.0 [0.0-1.0]s) and frequent serious no-flow (interruption>10s) occurred with DL (18/69 [26.1%]) compared with VL (0/71) (p<0.001). For highly experienced intubators (>80 successful ETIs), frequent serious no-flow occurred in DL (14/55 [25.5%] vs. 0/57 in VL). The ETI success, speed and complications during CPR did not differ significantly between the two devices for experienced intubators. However, the VL was superior in terms of completion of ETI without chest compression interruptions. Clinical Research Information Service (CRIS) in South Korea KCT0000849. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Ultrasound use during cardiopulmonary resuscitation is associated with delays in chest compressions.

    PubMed

    Huis In 't Veld, Maite A; Allison, Michael G; Bostick, David S; Fisher, Kiondra R; Goloubeva, Olga G; Witting, Michael D; Winters, Michael E

    2017-10-01

    High-quality chest compressions are a critical component of the resuscitation of patients in cardiopulmonary arrest. Point-of-care ultrasound (POCUS) is used frequently during emergency department (ED) resuscitations, but there has been limited research assessing its benefits and harms during the delivery of cardiopulmonary resuscitation (CPR). We hypothesized that use of POCUS during cardiac arrest resuscitation adversely affects high-quality CPR by lengthening the duration of pulse checks beyond the current cardiopulmonary resuscitation guidelines recommendation of 10s. We conducted a prospective cohort study of adults in cardiac arrest treated in an urban ED between August 2015 and September 2016. Resuscitations were recorded using video equipment in designated resuscitation rooms, and the use of POCUS was documented and timed. A linear mixed-effects model was used to estimate the effect of POCUS on pulse check duration. Twenty-three patients were enrolled in our study. The mean duration of pulse checks with POCUS was 21.0s (95% CI, 18-24) compared with 13.0s (95% CI, 12-15) for those without POCUS. POCUS increased the duration of pulse checks and CPR interruption by 8.4s (95% CI, 6.7-10.0 [p<0.0001]). Age, body mass index (BMI), and procedures did not significantly affect the duration of pulse checks. The use of POCUS during cardiac arrest resuscitation was associated with significantly increased duration of pulse checks, nearly doubling the 10-s maximum duration recommended in current guidelines. It is important for acute care providers to pay close attention to the duration of interruptions in the delivery of chest compressions when using POCUS during cardiac arrest resuscitation. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Barriers to dispatcher-assisted cardiopulmonary resuscitation in Singapore.

    PubMed

    Ho, Andrew Fu Wah; Sim, Zariel Jiaying; Shahidah, Nur; Hao, Ying; Ng, Yih Yng; Leong, Benjamin S H; Zarinah, Siti; Teo, Winston K L; Goh, Geraldine Shu Yi; Jaafar, Hamizah; Ong, Marcus E H

    2016-08-01

    Dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) is effective in increasing bystander CPR in out-of-hospital cardiac arrests (OHCA). Singapore has recently implemented a DA-CPR program. We aimed to characterize barriers to commencement of chest compressions by callers in Singapore. We analyzed dispatch recordings of OHCA cases received by the ambulance call center between July 2012 and March 2015. Audio recordings of poor quality were excluded. Trained reviewers noted the sequential stages of the dispatcher's recognition of CPR, delivering CPR instructions and caller performing CPR. Time taken to reach these milestones was noted. Barriers to chest compressions were identified. A total of 4897 OHCA occurred during the study period, overall bystander CPR rate was 45.7%. 1885 dispatch recordings were reviewed with 1157 cases qualified for dispatcher CPR. In 1128 (97.5%) cases, the dispatcher correctly recognized the need for CPR. CPR instructions were delivered in 1056 (91.3%) cases. Of these, 1007 (87.0%) callers performed CPR to instruction. One or more barriers to chest compressions were identified in 430 (37.2%) cases. The commonest barrier identified was "could not move patient" (27%). Cases where barriers were identified were less likely to have the need for CPR recognized by the dispatcher (94.9% vs. 99.0%, p<0.001), CPR instructions given (79.3% vs. 98.3%, p<0.001) and CPR started (67.9% vs. 98.3%, p<0.001), while the time taken to reach each of these stages were significantly longer (p<0.001). Barriers were present in 37% of cases. They were associated with lower proportion of CPR started and longer delay to CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. The impact of post-resuscitation feedback for paramedics on the quality of cardiopulmonary resuscitation.

    PubMed

    Bleijenberg, Eduard; Koster, Rudolph W; de Vries, Hendrik; Beesems, Stefanie G

    2017-01-01

    The Guidelines place emphasis on high-quality cardiopulmonary resuscitation (CPR). This study aims to measure the impact of post-resuscitation feedback on the quality of CPR as performed by ambulance personnel. Two ambulances are dispatched for suspected cardiac arrest. The crew (driver and paramedic) of the first arriving ambulance is responsible for the quality of CPR. The crew of the second ambulance establishes an intravenous access and supports the first crew. All resuscitation attempts led by the ambulance crew of the study region were reviewed by two research paramedics and structured feedback was given based on defibrillator recording with impedance signal. A 12-months period before introduction of post-resuscitation feedback was compared with a 19-months period after introduction of feedback, excluding a six months run-in interval. Quality parameters were chest compression fraction (CCF), chest compression rate, longest peri-shock pause and longest non-shock pause. In the pre-feedback period 55 cases were analyzed and 69 cases in the feedback period. Median CCF improved significantly in the feedback period (79% vs 86%, p<0.001). The mean chest compression rate was within the recommended range of 100-120/min in 87% of the cases in the pre-feedback period and in 90% of the cases in the feedback period (p=0.65). The duration of longest non-shock pause decreased significantly (40s vs 19s, p<0.001), the duration of the longest peri-shock pause did not change significantly (16s vs 13s, p=0.27). Post-resuscitation feedback improves the quality of resuscitation, significantly increasing CCF and decreasing the duration of longest non-shock pauses. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Hands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study.

    PubMed

    Schuerner, Philipp; Grande, Bastian; Piegeler, Tobias; Schlaepfer, Martin; Saager, Leif; Hutcherson, Matthew T; Spahn, Donat R; Ruetzler, Kurt

    2016-01-01

    Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been introduced to better visualize the vocal cords and accelerate intubation, which makes endotracheal intubation much safer and may contribute to intubation success. Therefore, we aimed to compare hands-off time and intubation success of direct laryngoscopy with videolaryngoscopy (C-MAC, Karl Storz, Tuttlingen, Germany) in a randomized, cross-over manikin study. Twenty-six anesthesia residents and twelve anesthesia consultants of the University Hospital Zurich were recruited through a voluntary enrolment. All participants performed endotracheal intubation using direct laryngoscopy and C-MAC in a random order during ongoing chest compressions. Participants were strictly advised to stop chest compression only if necessary. The median hands-off time was 1.9 seconds in direct laryngoscopy, compared to 3 seconds in the C-MAC group. In direct laryngoscopy 39 intubation attempts were recorded, resulting in an overall first intubation attempt success rate of 97%, compared to 38 intubation attempts and 100% overall first intubation attempt success rate in the C-MAC group. As a conclusion, the results of our manikin-study demonstrate that video laryngoscopes might not be beneficial compared to conventional, direct laryngoscopy in easily accessible airways under CPR conditions and in experienced hands. The benefits of video laryngoscopes are of course more distinct in overcoming difficult airways, as it converts a potential "blind intubation" into an intubation under visual control.

  16. [Extra longtime continuous chest compression to rescue cardiopulmonary arrest: a case report and the literature review].

    PubMed

    Zhang, Yan; Yue, Tianxue; Sun, Kexin; Wang, Jiang; Zhu, Ruiwu

    2018-05-01

    The new cardiopulmonary resuscitation (CPR) guideline emphasize the importance of chest compression, which was considered as the first step to CPR. The duration for CPR is usually limited to 30 minutes. With the development of new technology and evidence-based medicine, the success of extra longtime CPR has become possible, which is of great significance to some patients with cardiac arrest (CA), but the time limit has not been determined. On February 23rd in 2016, a 76-year-old female patient with respiratory and cardiac arrest who was on the third day after transurethral resection of bladder tumor (TUR-BT) was admitted to the intensive care unit of the General Hospital of Fushun Mining Bureau. On the basis of the comprehensive treatment measures such as ventilator support ventilation, physical cooling with ice cap, 1 mg adrenaline for intravenous injection, low molecular heparin of 5 000 U for subcutaneous injection, and the continuous chest compression were carried out in a timely and effective manner for 125 minutes, which make the patient recover to sinus rhythm and her brain function recovered well without any sequelae, and follow-up of the patient in 1 year showed well. The key to success or failure of CPR depend on the patient's condition. If the patients in healthy, single cause, a good response to the resuscitation, the pulsation of the large artery can be seen now and then during the rescue, and the recovery of the spontaneous breathing, CPR should be kept on. In the process of CPR, individualized assessment of the disease progression without the 30-minute time limit, may benefit the patients in maximum. In the future clinical practice, we should actively explore more favorable evidence, so that CA patients can be rescued more.

  17. Effect of the laryngeal tube on the no-flow-time in a simulated two rescuer basic life support setting with inexperienced users.

    PubMed

    Schröder, J; Bucher, M; Meyer, O

    2016-09-01

    Intubation with a laryngeal tube (LT) is a recommended alternative to endotracheal intubation during advanced life support (ALS). LT insertion is easy; therefore, it may also be an alternative to bag-mask ventilation (BMV) for untrained personnel performing basic life support (BLS). Data from manikin studies support the influence of LT on no-flow-time (NFT) during ALS. We performed a prospective, randomized manikin study using a two-rescuer model to compare the effects of ventilation using a LT and BMV on NFT during BLS. Participants were trained in BMV and were inexperienced in the use of a LT. There was no significant difference in total NFT with the use of a LT and BMV (LT: mean 83.1 ± 37.3 s; BMV: mean 78.7 ± 24.5 s; p = 0.313), but we found significant differences in the progression of the scenario: in the BLS-scenario, the proportion of time spent performing chest compressions was higher when BMV was used compared to when a LT was used. The quality of chest compressions and the ventilation rate did not differ significantly between the two groups. The mean tidal volume and mean minute volume were significantly larger with the use of a LT compared with the use of BMV. In conclusion, in a two-rescuer BLS scenario, NFT is longer with the use of a LT (without prior training) than with the use of BMV (with prior training). The probable reasons for this result are higher tidal volumes with the use of a LT leading to longer interruptions without chest compressions.

  18. Effect of using a laryngeal tube on the no-flow time in a simulated, single-rescuer, basic life support setting with inexperienced users.

    PubMed

    Meyer, O; Bucher, M; Schröder, J

    2016-03-01

    The laryngeal tube (LT) is a recommended alternative to endotracheal intubation during advanced life support (ALS). Its insertion is relatively simple; therefore, it may also serve as an alternative to bag mask ventilation (BMV) for untrained personnel performing basic life support (BLS). Data support the influence of LT on the no-flow time (NFT) compared with BMV during ALS in manikin studies. We performed a manikin study to investigate the effect of using the LT for ventilation instead of BMV on the NFT during BLS in a prospective, randomized, single-rescuer study. All 209 participants were trained in BMV, but were inexperienced in using LT; each participant performed BLS during a 4-min time period. No significant difference in total NFT (LT: mean 81.1 ± 22.7 s; BMV: mean 83.2 ± 13.1 s, p = 0.414) was found; however, significant differences in the later periods of the scenario were identified. While ventilating with the LT, the proportion of chest compressions increased significantly from 67.2 to 73.2%, whereas the proportion of chest compressions increased only marginally when performing BMV. The quality of the chest compressions and the associated ventilation rate did not differ significantly. The mean tidal volume and mean minute volume were significantly lower when performing BMV. The NFT was significantly shorter in the later periods in a single-rescuer, cardiac arrest scenario when using an LT without previous training compared with BMV with previous training. A possible explanation for this result may be the complexity and workload of alternating tasks (e.g., time loss when reclining the head and positioning the mask for each ventilation during BMV).

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, J.S.; Miyamoto, Y.

    The fracture behavior of graded Al{sub 2}O{sub 3}/TiC/Ni materials with a symmetric structure was investigated using single-edge notch-bend (SENB) specimens with surface compression. The fracture toughness of the graded materials was determined according to ASTM Standard E399. The results show that the effective fracture toughness increases with an increase in notch depth in the compressive stress zone, and reaches the maximum of 39.2 MPa m{sup 1/2} at the interface of compressive/tensile stress zones. Finite elements analysis reveals that the surface compression will be intensified at the notch root once the specimen is edge-notched because of the stress concentration, and themore » digress of the compressive stress intensification increases with an increase in notch depth. The dependence of the effective fracture toughness of the graded materials on the notch depth shows a behavior similar to the R-curve that is usually associated with microstructural toughening mechanisms. This toughening behavior is caused by the intensification of the compressive stress concentration with the increase of the notch depth. A theoretical analysis based on fracture mechanics verifies that the mechanical reliability of brittle ceramics can be improved effectively by tailoring and controlling the internal stresses.« less

  20. LUCAS(™)2 in Danish Search and Rescue Helicopters.

    PubMed

    Winther, Kasper; Bleeg, René Christian

    2016-01-01

    Prehospital resuscitation is often challenging. Giving uninterrupted and effective compressions is relatively impossible during transportation. In 2012, The Royal Danish Air Force received a donation of 8 mechanical chest compression devices (LUCAS(™)2; Physio-Control/Jolife AB, Lund, Sweden) to be used onboard the Danish search and rescue (SAR) helicopters. The scope of this investigation was to establish whether or not mechanical chest compression devices should be considered a necessity onboard the Danish SAR helicopters. Data were compiled from SAR medical journals. From the data collected, observations were made as to when LUCAS(™)2 was used and what diagnosis the SAR physician made. One thousand ninety missions were registered in the 24-month research period, and LUCAS(™)2 was used in 25 missions. Cardiac emergencies amounted for 25% of the missions. The Danish SAR helicopters retrieved 33 drowned/hypothermic patients during the research period, and the LUCAS(™)2 was used in 11 of the patients requiring resuscitation. The LUCAS(™)2 was frequently used during other emergencies like sudden cardiac arrest. Cardiac emergencies were the predominant type of mission. LUCAS(™)2 is now considered mandatory on Danish SAR helicopters. Copyright © 2016 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  1. Why do some studies find that CPR fraction is not a predictor of survival?

    PubMed

    Wik, Lars; Olsen, Jan-Aage; Persse, David; Sterz, Fritz; Lozano, Michael; Brouwer, Marc A; Westfall, Mark; Souders, Chris M; Travis, David T; Herken, Ulrich R; Lerner, E Brooke

    2016-07-01

    An 80% chest compression fraction (CCF) during resuscitation is recommended. However, heterogeneous results in CCF studies were found during the 2015 Consensus on Science (CoS), which may be because chest compressions are stopped for a wide variety of reasons including providing lifesaving care, provider distraction, fatigue, confusion, and inability to perform lifesaving skills efficiently. The effect of confounding variables on CCF to predict cardiac arrest survival. A secondary analysis of emergency medical services (EMS) treated out-of-hospital cardiac arrest (OHCA) patients who received manual compressions. CCF (percent of time patients received compressions) was determined from electronic defibrillator files. Two Sample Wilcoxon Rank Sum or regression determined a statistical association between CCF and age, gender, bystander CPR, public location, witnessed arrest, shockable rhythm, resuscitation duration, study site, and number of shocks. Univariate and multivariate logistic regressions were used to determine CCF effect on survival. Of 2132 patients with manual compressions 1997 had complete data. Shockable rhythm (p<0.001), public location (p<0.004), treatment duration (p<0.001), and number of shocks (p<0.001) were associated with lower CCF. Univariate logistic regression found that CCF was inversely associated with survival (OR 0.07; 95% CI 0.01-0.36). Multivariate regression controlling for factors associated with survival and/or CCF found that increasing CCF was associated with survival (OR 6.34; 95% CI 1.02-39.5). CCF cannot be looked at in isolation as a predictor of survival, but in the context of other resuscitation activities. When controlling for the effects of other resuscitation activities, a higher CCF is predictive of survival. This may explain the heterogeneity of findings during the CoS review. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Rescuer fatigue during actual in-hospital cardiopulmonary resuscitation with audiovisual feedback: a prospective multicenter study

    PubMed Central

    Sugerman, Noah T.; Herzberg, Daniel; Leary, Marion; Weidman, Elizabeth K.; Edelson, Dana P.; Vanden Hoek, Terry L.; Becker, Lance B.; Abella, Benjamin S.

    2009-01-01

    Background Rescuer fatigue during cardiopulmonary resuscitation (CPR) is a likely contributor to variable CPR quality during clinical resuscitation efforts, yet investigations into fatigue and CPR quality degradation have only been performed in simulated environments, with widely conflicting results. Objective We sought to characterize CPR quality decay during actual in-hospital cardiac arrest, with regard to both chest compression (CC) rate and depth during the delivery of CCs by individual rescuers over time. Methods Using CPR-recording technology to objectively quantify CCs and provide audiovisual feedback, we prospectively collected CPR performance data from arrest events in two hospitals. We identified continuous CPR “blocks” from individual rescuers, assessing CC rate and depth over time. Results 135 blocks of continuous CPR were identified from 42 cardiac arrests at the two institutions. Median duration of continuous CPR blocks was 112 sec (IQR 101–122). CC rate did not change significantly over single rescuer performance, with an initial mean rate of 105 ± 11 / min, and a mean rate after 3 min of 106 ± 9 / min (p=NS). However, CC depth decayed significantly starting between 90 sec and 2 min, falling from a mean of 48.3 ± 9.6 mm to 46.0 ± 9.0 mm (p=0.0006) and to 43.7 ± 7.4 mm by 3 minutes (p=0.002). Conclusions During actual in-hospital CPR with audiovisual feedback, CC depth decay became evident after 90 sec of CPR, but CC rate did not change. These data provide clinical evidence for rescuer fatigue during actual resuscitations and support current guideline recommendations to rotate rescuers during CC delivery. PMID:19581036

  3. A Quantitative Analysis of Out-of-Hospital Pediatric and Adolescent Resuscitation Quality–A Report from the ROC Epistry–Cardiac Arrest

    PubMed Central

    Sutton, Robert M.; Case, Erin; Brown, Siobhan P.; Atkins, Dianne L.; Nadkarni, Vinay M.; Kaltman, Jonathan; Callaway, Clifton W.; Idris, Ahamed H.; Nichol, Graham; Hutchison, Jamie; Drennan, Ian R.; Austin, Michael A; Daya, Mohamud; Cheskes, Sheldon; Nuttall, Jack; Herren, Heather; Christenson, James; Andrusiek, Douglas L; Vaillancourt, Christian; Menegazzi, James J.; Rea, Thomas D.; Berg, Robert A.

    2015-01-01

    Aim High-quality cardiopulmonary resuscitation (CPR) may improve survival. The quality of CPR performed during pediatric out-of-hospital cardiac arrest (p-OHCA) is largely unknown. The main objective of this study was to describe the quality of CPR performed during p-OHCA resuscitation attempts. Methods Prospective observational multi-center cohort study of p-OHCA patients ≥1 and < 19 years of age registered in the Resuscitation Outcomes Consortium (ROC) Epistry database. The primary outcome was an a priori composite variable of compliance with American Heart Association (AHA) guidelines for both chest compression (CC) rate and CC fraction (CCF). Event compliance was defined as a case with 60% or more of its minute epochs compliant with AHA targets (rate 100–120 min−1; depth ≥38 mm; and CCF ≥0.80). In a secondary analysis, multivariable logistic regression was used to evaluate the association between guideline compliance and return of spontaneous circulation (ROSC). Results Between December 2005 and December 2012, 2,564 pediatric events were treated by EMS providers, 390 of which were included in the final cohort. Of these events, 22% achieved AHA compliance for both rate and CCF, 36% for rate alone, 53% for CCF alone, and 58% for depth alone. Over time, there was a significant increase in CCF (p< 0.001) and depth (p=0.03). After controlling for potential confounders, there was no significant association between AHA guideline compliance and ROSC. Conclusions In this multi-center study, we have established that there are opportunities for professional rescuers to improve prehospital CPR quality. Encouragingly, CCF and depth both increased significantly over time. PMID:25917262

  4. The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children.

    PubMed

    Gregson, Rachael K; Shannon, Harriet; Stocks, Janet; Cole, Tim J; Peters, Mark J; Main, Eleanor

    2012-03-01

    This study aimed to quantify the specific effects of manual lung inflations with chest compression-vibrations, commonly used to assist airway clearance in ventilated patients. The hypothesis was that force applied during the compressions made a significant additional contribution to increases in peak expiratory flow and expiratory to inspiratory flow ratio over and above that resulting from accompanying increases in inflation volume. Prospective observational study. Cardiac and general pediatric intensive care. Sedated, fully ventilated children. Customized force-sensing mats and a commercial respiratory monitor recorded force and respiration during physiotherapy. Percentage changes in peak expiratory flow, peak expiratory to inspiratory flow ratios, inflation volume, and peak inflation pressure between baseline and manual inflations with and without compression-vibrations were calculated. Analysis of covariance determined the relative contribution of changes in pressure, volume, and force to influence changes in peak expiratory flow and peak expiratory to inspiratory flow ratio. Data from 105 children were analyzed (median age, 1.3 yrs; range, 1 wk to 15.9 yrs). Force during compressions ranged from 15 to 179 N (median, 46 N). Peak expiratory flow increased on average by 76% during compressions compared with baseline ventilation. Increases in peak expiratory flow were significantly related to increases in inflation volume, peak inflation pressure, and force with peak expiratory flow increasing by, on average, 4% for every 10% increase in inflation volume (p < .001), 5% for every 10% increase in peak inflation pressure (p = .005), and 3% for each 10 N of applied force (p < .001). By contrast, increase in peak expiratory to inspiratory flow ratio was only related to applied force with a 4% increase for each 10 N of force (p < .001). These results provide evidence of the unique contribution of compression forces in increasing peak expiratory flow and peak expiratory to inspiratory flow ratio bias over and above that related to accompanying changes from manual hyperinflations. Force generated during compression-vibrations was the single significant factor in multivariable analysis to explain the increases in expiratory flow bias. Such increases in the expiratory bias provide theoretically optimal physiological conditions for cephalad mucus movement in fully ventilated children.

  5. Applications of just-noticeable depth difference model in joint multiview video plus depth coding

    NASA Astrophysics Data System (ADS)

    Liu, Chao; An, Ping; Zuo, Yifan; Zhang, Zhaoyang

    2014-10-01

    A new multiview just-noticeable-depth-difference(MJNDD) Model is presented and applied to compress the joint multiview video plus depth. Many video coding algorithms remove spatial and temporal redundancies and statistical redundancies but they are not capable of removing the perceptual redundancies. Since the final receptor of video is the human eyes, we can remove the perception redundancy to gain higher compression efficiency according to the properties of human visual system (HVS). Traditional just-noticeable-distortion (JND) model in pixel domain contains luminance contrast and spatial-temporal masking effects, which describes the perception redundancy quantitatively. Whereas HVS is very sensitive to depth information, a new multiview-just-noticeable-depth-difference(MJNDD) model is proposed by combining traditional JND model with just-noticeable-depth-difference (JNDD) model. The texture video is divided into background and foreground areas using depth information. Then different JND threshold values are assigned to these two parts. Later the MJNDD model is utilized to encode the texture video on JMVC. When encoding the depth video, JNDD model is applied to remove the block artifacts and protect the edges. Then we use VSRS3.5 (View Synthesis Reference Software) to generate the intermediate views. Experimental results show that our model can endure more noise and the compression efficiency is improved by 25.29 percent at average and by 54.06 percent at most compared to JMVC while maintaining the subject quality. Hence it can gain high compress ratio and low bit rate.

  6. Evaluation of the field relevance of several injury risk functions.

    PubMed

    Prasad, Priya; Mertz, Harold J; Dalmotas, Danius J; Augenstein, Jeffrey S; Diggs, Kennerly

    2010-11-01

    An evaluation of the four injury risk curves proposed in the NHTSA NCAP for estimating the risk of AIS>= 3 injuries to the head, neck, chest and AIS>=2 injury to the Knee-Thigh-Hip (KTH) complex has been conducted. The predicted injury risk to the four body regions based on driver dummy responses in over 300 frontal NCAP tests were compared against those to drivers involved in real-world crashes of similar severity as represented in the NASS. The results of the study show that the predicted injury risks to the head and chest were slightly below those in NASS, and the predicted risk for the knee-thigh-hip complex was substantially below that observed in the NASS. The predicted risk for the neck by the Nij curve was greater than the observed risk in NASS by an order of magnitude due to the Nij risk curve predicting a non-zero risk when Nij = 0. An alternative and published Nte risk curve produced a risk estimate consistent with the NASS estimate of neck injury. Similarly, an alternative and published chest injury risk curve produced a risk estimate that was within the bounds of the NASS estimates. No published risk curve for femur compressive load could be found that would give risk estimates consistent with the range of the NASS estimates. Additional work on developing a femur compressive load risk curve is recommended.

  7. Subjective evaluation of mobile 3D video content: depth range versus compression artifacts

    NASA Astrophysics Data System (ADS)

    Jumisko-Pyykkö, Satu; Haustola, Tomi; Boev, Atanas; Gotchev, Atanas

    2011-02-01

    Mobile 3D television is a new form of media experience, which combines the freedom of mobility with the greater realism of presenting visual scenes in 3D. Achieving this combination is a challenging task as greater viewing experience has to be achieved with the limited resources of the mobile delivery channel such as limited bandwidth and power constrained handheld player. This challenge sets need for tight optimization of the overall mobile 3DTV system. Presence of depth and compression artifacts in the played 3D video are two major factors that influence viewer's subjective quality of experience and satisfaction. The primary goal of this study has been to examine the influence of varying depth and compression artifacts on the subjective quality of experience for mobile 3D video content. In addition, the influence of the studied variables on simulator sickness symptoms has been studied and vocabulary-based descriptive quality of experience has been conducted for a sub-set of variables in order to understand the perceptual characteristics in detail. In the experiment, 30 participants have evaluated the overall quality of different 3D video contents with varying depth ranges and compressed with varying quantization parameters. The test video content has been presented on a portable autostereoscopic LCD display with horizontal double density pixel arrangement. The results of the psychometric study indicate that compression artifacts are a dominant factor determining the quality of experience compared to varying depth range. More specifically, contents with strong compression has been rejected by the viewers and deemed unacceptable. The results of descriptive study confirm the dominance of visible spatial artifacts along the added value of depth for artifact-free content. The level of visual discomfort has been determined as not offending.

  8. The effect of step stool use and provider height on CPR quality during pediatric cardiac arrest: A simulation-based multicentre study.

    PubMed

    Cheng, Adam; Lin, Yiqun; Nadkarni, Vinay; Wan, Brandi; Duff, Jonathan; Brown, Linda; Bhanji, Farhan; Kessler, David; Tofil, Nancy; Hecker, Kent; Hunt, Elizabeth A

    2018-01-01

    We aimed to explore whether a) step stool use is associated with improved cardiopulmonary resuscitation (CPR) quality; b) provider adjusted height is associated with improved CPR quality; and if associations exist, c) determine whether just-in-time (JIT) CPR training and/or CPR visual feedback attenuates the effect of height and/or step stool use on CPR quality. We analysed data from a trial of simulated cardiac arrests with three study arms: No intervention; CPR visual feedback; and JIT CPR training. Step stool use was voluntary. We explored the association between 1) step stool use and CPR quality, and 2) provider adjusted height and CPR quality. Adjusted height was defined as provider height + 23 cm (if step stool was used). Below-average height participants were ≤ gender-specific average height; the remainder were above average height. We assessed for interaction between study arm and both adjusted height and step stool use. One hundred twenty-four subjects participated; 1,230 30-second epochs of CPR were analysed. Step stool use was associated with improved compression depth in below-average (female, p=0.007; male, p<0.001) and above-average (female, p=0.001; male, p<0.001) height providers. There is an association between adjusted height and compression depth (p<0.001). Visual feedback attenuated the effect of height (p=0.025) on compression depth; JIT training did not (p=0.918). Visual feedback and JIT training attenuated the effect of step stool use (p<0.001) on compression depth. Step stool use is associated with improved compression depth regardless of height. Increased provider height is associated with improved compression depth, with visual feedback attenuating the effects of height and step stool use.

  9. Effects and limitations of an AED with audiovisual feedback for cardiopulmonary resuscitation: a randomized manikin study.

    PubMed

    Fischer, Henrik; Gruber, Julia; Neuhold, Stephanie; Frantal, Sophie; Hochbrugger, Eva; Herkner, Harald; Schöchl, Herbert; Steinlechner, Barbara; Greif, Robert

    2011-07-01

    Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons. With ethics committee approval and informed consent, 68 teams (2 flight attendants each) performed 12 min of standard CPR with the AED's audiovisual feedback mechanism enabled or disabled. We recorded CPR quality parameters during resuscitation on a manikin in this open, prospective, randomized controlled trial. Between the feedback and control-group we measured differences in compression depth and rate as main outcome parameters and effective compressions, correct hand position, and incomplete decompression as secondary outcome parameters. An effective compression was defined as a compression with correct depth, hand position, and decompression. The feedback-group delivered compression rates closest to the recommended guidelines (101 ± 9 vs. 109 ± 15/min, p=0.009), more effective compressions (20 ± 18 vs. 5 ± 6%, p<0.001), more compressions with correct hand position (96 ± 13 vs. 88 ± 16%, p<0.001), and less leaning (21 ± 31 vs. 77 ± 33%, p<0.001). However, only the control-group adhered to the recommended compression depth (44 ± 7 mm vs. 39 ± 6, p=0.003). Use of an AED's audiovisual feedback system improved some CPR-quality parameters, thus confirming findings of earlier studies with the notable exception of decreased compression depth, which is a key parameter that might be linked to reduced cardiac output. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Non-censored rib fracture data during frontal PMHS sled tests.

    PubMed

    Kemper, Andrew R; Beeman, Stephanie M; Porta, David J; Duma, Stefan M

    2016-09-01

    The purpose of this study was to obtain non-censored rib fracture data due to three-point belt loading during dynamic frontal post-mortem human surrogate (PMHS) sled tests. The PMHS responses were then compared to matched tests performed using the Hybrid-III 50(th) percentile male ATD. Matched dynamic frontal sled tests were performed on two male PMHSs, which were approximately 50(th) percentile height and weight, and the Hybrid-III 50(th) percentile male ATD. The sled pulse was designed to match the vehicle acceleration of a standard sedan during a FMVSS-208 40 kph test. Each subject was restrained with a 4 kN load limiting, driver-side, three-point seatbelt. A 59-channel chestband, aligned at the nipple line, was used to quantify the chest contour, anterior-posterior sternum deflection, and maximum anterior-posterior chest deflection for all test subjects. The internal sternum deflection of the ATD was quantified with the sternum potentiometer. For the PMHS tests, a total of 23 single-axis strain gages were attached to the bony structures of the thorax, including the ribs, sternum, and clavicle. In order to create a non-censored data set, the time history of each strain gage was analyzed to determine the timing of each rib fracture and corresponding timing of each AIS level (AIS = 1, 2, 3, etc.) with respect to chest deflection. Peak sternum deflection for PMHS 1 and PMHS 2 were 48.7 mm (19.0%) and 36.7 mm (12.2%), respectively. The peak sternum deflection for the ATD was 20.8 mm when measured by the chest potentiometer and 34.4 mm (12.0%) when measured by the chestband. Although the measured ATD sternum deflections were found to be well below the current thoracic injury criterion (63 mm) specified for the ATD in FMVSS-208, both PMHSs sustained AIS 3+ thoracic injuries. For all subjects, the maximum chest deflection measured by the chestband occurred to the right of the sternum and was found to be 83.0 mm (36.0%) for PMHS 1, 60.6 mm (23.9%) for PMHS 2, and 56.3 mm (20.0%) for the ATD. The non-censored rib fracture data in the current study (n = 2 PMHS) in conjunction with the non-censored rib fracture data from two previous table-top studies (n = 4 PMHS) show that AIS 3+ injury timing occurs prior to peak sternum compression, prior to peak maximum chest compression, and at lower compressions than might be suggested by current PMHS thoracic injury criteria developed using censored rib fracture data. In addition, the maximum chest deflection results showed a more reasonable correlation between deflection, rib fracture timing, and injury severity than sternum deflection. Overall, these data provide compelling empirical evidence that suggests a more conservative thoracic injury criterion could potentially be developed based on non-censored rib fracture data with additional testing performed over a wider range of subjects and loading conditions.

  11. Treatment of atelectasis: where is the evidence?

    PubMed Central

    Schindler, Margrid B

    2005-01-01

    Lobar atelectasis is a common problem caused by a variety of mechanisms including resorption atelectasis due to airway obstruction, passive atelectasis from hypoventilation, compressive atelectsis from abdominal distension and adhesive atelectasis due to increased surface tension. However, evidence-based studies on the management of lobar atelectasis are lacking. Examination of air-bronchograms on a chest radiograph may be helpful to determine whether proximal or distal airway obstruction is involved. Chest physiotherapy, nebulised DNase and possibly fibreoptic bronchoscopy might be helpful in patients with mucous plugging of the airways. In passive and adhesive atelectasis, positive end-expiratory pressure might be a useful adjunct to treatment. PMID:16137380

  12. Effect of cold compress application on tissue temperature in healthy dogs.

    PubMed

    Millard, Ralph P; Towle-Millard, Heather A; Rankin, David C; Roush, James K

    2013-03-01

    To measure the effect of cold compress application on tissue temperature in healthy dogs. 10 healthy mixed-breed dogs. Dogs were sedated with hydromorphone (0.1 mg/kg, IV) and diazepam (0.25 mg/kg, IV). Three 24-gauge thermocouple needles were inserted to a depth of 0.5 (superficial), 1.0 (middle), and 1.5 (deep) cm into a shaved, lumbar, epaxial region to measure tissue temperature. Cold (-16.8°C) compresses were applied with gravity dependence for periods of 5, 10, and 20 minutes. Tissue temperature was recorded before compress application and at intervals for up to 80 minutes after application. Control data were collected while dogs received identical sedation but with no cold compress. Mean temperature associated with 5 minutes of application at the superficial depth was significantly decreased, compared with control temperatures. Application for 10 and 20 minutes significantly reduced the temperature at all depths, compared with controls and 5 minutes of application. Twenty minutes of application significantly decreased temperature at only the middle depth, compared with 10 minutes of application. With this method of cold treatment, increasing application time from 10 to 20 minutes caused a further significant temperature change at only the middle tissue depth; however, for maximal cooling, the minimum time of application should be 20 minutes. Possible changes in tissue temperature and adverse effects of application > 20 minutes require further evaluation.

  13. [Factors affecting the survival of transplants from donors after prehospital cardiac death].

    PubMed

    Mateos Rodríguez, Alonso Antonio; Andrés Belmonte, Amado; Del Río Gallegos, Francisco; Coll, Elisabeth

    2017-06-01

    To evaluate factors that influence the survival of transplanted organs from donors after prehospital cardiac death. Retrospective observational study of data collected from hospital emergency service records. Information included prehospital cardiac deaths evaluated as donors as well as patients who received transplants. Two hundred cases from 2008 through 2011 were studied. Sixty-nine potential donors (34.5%) were rejected. Three hundred organs were extracted from the remaining 131 donor cases, to yield a mean (SD) of 2.32 (0.83) transplanted organs/donor or 1.52 (1.29) organs/potential donor. One hundred fifty-two potential donors (76%) were treated with mechanical cardiopumps during transport. We detected no significant differences between cases transported with manual chest compressions and cases treated with cardiopumps regarding age (40.1 vs 43.5 years, P=.06), responder arrival times (13 min 54 s vs 12 min 54 s, P=.45), or transport times (1 h 27 min vs 1 h 32 min). However, case transported with manual chest compressions yielded significantly more kidneys (mean, 1.96/potential donor) than those transported with cardiopump compressions (mean, 1.38/potential donor) (P=.008). Eleven of the 229 kidneys harvested (4%) were not transplanted. The median (interquartile range) serum creatinine concentrations after kidney transplants at 6 and 12 months, respectively, were 1.37 (1.10-1.58) mg/dL and 1.43 (1.11-1.80) mg/dL. Our findings suggest that the use of a cardiopump reduces donor recruitment. Long-term creatinine levels are similar after transplantation of kidneys from donors transported with a cardiopump or with manual compressions.

  14. Estimating the effect of lung collapse and pulmonary shunt on gas exchange during breath-hold diving: the Scholander and Kooyman legacy.

    PubMed

    Fahlman, A; Hooker, S K; Olszowka, A; Bostrom, B L; Jones, D R

    2009-01-01

    We developed a mathematical model to investigate the effect of lung compression and collapse (pulmonary shunt) on the uptake and removal of O(2), CO(2) and N(2) in blood and tissue of breath-hold diving mammals. We investigated the consequences of pressure (diving depth) and respiratory volume on pulmonary shunt and gas exchange as pressure compressed the alveoli. The model showed good agreement with previous studies of measured arterial O(2) tensions (Pa(O)(2)) from freely diving Weddell seals and measured arterial and venous N(2) tensions from captive elephant seals compressed in a hyperbaric chamber. Pulmonary compression resulted in a rapid spike in Pa(O)(2) and arterial CO(2) tension, followed by cyclical variation with a periodicity determined by Q(tot). The model showed that changes in diving lung volume are an efficient behavioural means to adjust the extent of gas exchange with depth. Differing models of lung compression and collapse depth caused major differences in blood and tissue N(2) estimates. Our integrated modelling approach contradicted predictions from simple models, and emphasised the complex nature of physiological interactions between circulation, lung compression and gas exchange. Overall, our work suggests the need for caution in interpretation of previous model results based on assumed collapse depths and all-or-nothing lung collapse models.

  15. Cardiopulmonary resuscitation training of family members before hospital discharge using video self-instruction: a feasibility trial.

    PubMed

    Blewer, Audrey L; Leary, Marion; Decker, Christopher S; Andersen, James C; Fredericks, Amanda C; Bobrow, Bentley J; Abella, Benjamin S

    2011-09-01

    Bystander cardiopulmonary resuscitation (CPR) is a crucial therapy for sudden cardiac arrest (SCA), yet rates of bystander CPR are low. This is especially the case for SCA occurring in the home setting, as family members of at-risk patients are often not CPR trained. To evaluate the feasibility of a novel hospital-based CPR education program targeted to family members of patients at increased risk for SCA. Prospective, multicenter, cohort study. Inpatient wards at 3 hospitals. Family members of inpatients admitted with cardiac-related diagnoses. Family members were offered CPR training via a proctored video-self instruction (VSI) program. After training, CPR skills and participant perspectives regarding their training experience were assessed. Surveys were conducted one month postdischarge to measure the rate of "secondary training" of other individuals by enrolled family members. At the 3 study sites, 756 subjects were offered CPR instruction; 280 agreed to training and 136 underwent instruction using the VSI program. Of these, 78 of 136 (57%) had no previous CPR training. After training, chest compression performance was generally adequate (mean compression rate 90 ± 26/minute, mean depth 37 ± 12 mm). At 1 month, 57 of 122 (47%) of subjects performed secondary training for friends or family members, with a calculated mean of 2.1 persons trained per kit distributed. The hospital setting offers a unique "point of capture" to provide CPR instruction to an important, undertrained population in contact with at-risk individuals. Copyright © 2010 Society of Hospital Medicine.

  16. Assessing the Hemodynamic Effects of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) in Traumatic Cardiac Arrest When Closed Chest Compressions are Augmented by Directing the Area of Maximal Compression Over the Left Ventricle in a Swine Model (sus scrofa)

    DTIC Science & Technology

    2016-09-15

    WHASC – Animal Final Report 18May16 1. Protocol Number: FWH200140094A 2. Type of Research: Animal Research 3. Title...6. Results: ROSC increased among standard CC animals with REBOA (33%) compared to standard CC animals without REBOA (0.0%) (p=0.04). Among...standard CC animals , aortic systolic blood pressure, right atrial systolic blood pressure and end tidal CO2 (ETCO2) increased during all time intervals of

  17. Traumatic asphyxia: An autopsy case.

    PubMed

    Türkmen, Nursel; Eren, Bülent; Erkol, Zerrin

    2015-01-01

    Traumatic asphyxia is a form of asphyxia where respiration is prevented by external pressure on the body. A 19-year-old man was found by relatives compressed by motorboat in the garage. The death was investigated by the prosecutor; body was taken to the Morgue Department for performing autopsy. On gross physical examination; the face, neck and upper part of the chest were congested and many petechiae were observed on the conjunctivae, but not in low extremities. Autopsy macroscopic examination of lungs revealed congestion, sub pleural superficial bleeding areas. In the presented case death was reported as traumatic asphyxia by thorax compression without other lethal factors.

  18. The cardiocerebral resuscitation protocol for treatment of out-of-hospital primary cardiac arrest.

    PubMed

    Ewy, Gordon A

    2012-09-15

    Out-of-hospital cardiac arrest (OHCA) is a significant public health problem in most westernized industrialized nations. In spite of national and international guidelines for cardiopulmonary resuscitation and emergency cardiac care, the overall survival of patients with OHCA was essentially unchanged for 30 years--from 1978 to 2008 at 7.6%. Perhaps a better indicator of Emergency Medical System (EMS) effectiveness in treating patients with OHCA is to focus on the subgroup that has a reasonable chance of survival, e.g., patients found to be in ventricular fibrillation (VF). But even in this subgroup, the average survival rate was 17.7% in the United States, unchanged between 1980 and 2003, and 21% in Europe, unchanged between 1980 and 2004. Prior to 2003, the survival of patients with OHCA, in VF in Tucson, Arizona was less than 9% in spite of incorporating previous guideline recommendations. An alternative (non-guidelines) approach to the therapy of patients with OHCA and a shockable rhythm, called Cardiocerebral Resuscitation, based on our extensive physiologic laboratory studies, was introduced in Tucson in 2003, in rural Wisconsin in 2004, and in selected EMS areas in the metropolitan Phoenix area in 2005. Survival of patients with OHCA due to VF treated with Cardiocerebral Resuscitation in rural Wisconsin increased to 38% and in 60 EMS systems in Arizona to 39%. In 2004, we began a statewide program to advocate chest compression-only CPR for bystanders of witnessed primary OHCA. Over the next five years, we found that survival of patients with a shockable rhythm was 17.7% in those treated with standard bystander CPR (mouth-to-mouth ventilations plus chest compression) compared to 33.7% for those who received bystander chest-compression-only CPR. This article on Cardiocerebral Resuscitation, by invitation following a presentation at the 2011 Danish Society Emergency Medical Conference, summarizes the results of therapy of patients with primary OHCA treated with Cardiocerebral Resuscitation, with requested emphasis on the EMS protocol.

  19. The Cardiocerebral Resuscitation protocol for treatment of out-of-hospital primary cardiac arrest

    PubMed Central

    2012-01-01

    Out-of-hospital cardiac arrest (OHCA) is a significant public health problem in most westernized industrialized nations. In spite of national and international guidelines for cardiopulmonary resuscitation and emergency cardiac care, the overall survival of patients with OHCA was essentially unchanged for 30 years--from 1978 to 2008 at 7.6%. Perhaps a better indicator of Emergency Medical System (EMS) effectiveness in treating patients with OHCA is to focus on the subgroup that has a reasonable chance of survival, e.g., patients found to be in ventricular fibrillation (VF). But even in this subgroup, the average survival rate was 17.7% in the United States, unchanged between 1980 and 2003, and 21% in Europe, unchanged between 1980 and 2004. Prior to 2003, the survival of patients with OHCA, in VF in Tucson, Arizona was less than 9% in spite of incorporating previous guideline recommendations. An alternative (non-guidelines) approach to the therapy of patients with OHCA and a shockable rhythm, called Cardiocerebral Resuscitation, based on our extensive physiologic laboratory studies, was introduced in Tucson in 2003, in rural Wisconsin in 2004, and in selected EMS areas in the metropolitan Phoenix area in 2005. Survival of patients with OHCA due to VF treated with Cardiocerebral Resuscitation in rural Wisconsin increased to 38% and in 60 EMS systems in Arizona to 39%. In 2004, we began a statewide program to advocate chest compression-only CPR for bystanders of witnessed primary OHCA. Over the next five years, we found that survival of patients with a shockable rhythm was 17.7% in those treated with standard bystander CPR (mouth-to-mouth ventilations plus chest compression) compared to 33.7% for those who received bystander chest-compression-only CPR. This article on Cardiocerebral Resuscitation, by invitation following a presentation at the 2011 Danish Society Emergency Medical Conference, summarizes the results of therapy of patients with primary OHCA treated with Cardiocerebral Resuscitation, with requested emphasis on the EMS protocol. PMID:22980487

  20. Real-time 3D video compression for tele-immersive environments

    NASA Astrophysics Data System (ADS)

    Yang, Zhenyu; Cui, Yi; Anwar, Zahid; Bocchino, Robert; Kiyanclar, Nadir; Nahrstedt, Klara; Campbell, Roy H.; Yurcik, William

    2006-01-01

    Tele-immersive systems can improve productivity and aid communication by allowing distributed parties to exchange information via a shared immersive experience. The TEEVE research project at the University of Illinois at Urbana-Champaign and the University of California at Berkeley seeks to foster the development and use of tele-immersive environments by a holistic integration of existing components that capture, transmit, and render three-dimensional (3D) scenes in real time to convey a sense of immersive space. However, the transmission of 3D video poses significant challenges. First, it is bandwidth-intensive, as it requires the transmission of multiple large-volume 3D video streams. Second, existing schemes for 2D color video compression such as MPEG, JPEG, and H.263 cannot be applied directly because the 3D video data contains depth as well as color information. Our goal is to explore from a different angle of the 3D compression space with factors including complexity, compression ratio, quality, and real-time performance. To investigate these trade-offs, we present and evaluate two simple 3D compression schemes. For the first scheme, we use color reduction to compress the color information, which we then compress along with the depth information using zlib. For the second scheme, we use motion JPEG to compress the color information and run-length encoding followed by Huffman coding to compress the depth information. We apply both schemes to 3D videos captured from a real tele-immersive environment. Our experimental results show that: (1) the compressed data preserves enough information to communicate the 3D images effectively (min. PSNR > 40) and (2) even without inter-frame motion estimation, very high compression ratios (avg. > 15) are achievable at speeds sufficient to allow real-time communication (avg. ~ 13 ms per 3D video frame).

  1. Advantage of vein grafts for anomalous origin of a right coronary artery.

    PubMed

    Kansaku, Rei; Saitoh, Hirofumi; Eguchi, Shoji; Maruyama, Yukio; Ohtsuka, Hideaki; Higuchi, Kotaro

    2009-03-01

    A 66-year-old man with anomalous origin of the right coronary artery suffered from chest pain. The results of coronary angiography and multidetector computer tomography indicated that the proximal right coronary artery was intermittently compressed, causing the ischemia. Coronary artery bypass grafting was regarded as a reliable treatment compared with percutaneous coronary intervention or other surgeries. Because of plentiful flow of the right coronary artery, we decided to use a vein graft to avoid competitive flow. Postoperative coronary angiography revealed intact flow in both the native coronary artery and the vein graft 1 year after the surgery. The myocardial ischemia seen on scintigraphy and the chest pain had disappeared.

  2. On the anisotropy of perceived ground extents and the interpretation of walked distance as a measure of perception

    PubMed Central

    Li, Zhi; Sun, Emily; Strawser, Cassandra J.; Spiegel, Ariana; Klein, Brennan; Durgin, Frank H.

    2012-01-01

    Two experiments are reported concerning the perception of ground extent in order to discover whether prior reports of anisotropy between frontal extents and extents in depth were consistent across different measures (visual matching and pantomime walking) and test environments (outdoor environments and virtual environments). In Experiment 1 it was found that depth extents of up to 7 m are indeed perceptually compressed relative to frontal extents in an outdoor environment, and that perceptual matching provided more precise estimates than did pantomime walking. In Experiment 2, similar anisotropies were found using similar tasks in a similar (but virtual) environment. In both experiments pantomime walking measures seemed to additionally compress the range of responses. Experiment 3 supported the hypothesis that range compression in walking measures of perceived distance might be due to proactive interference (memory contamination). It is concluded that walking measures are calibrated for perceived egocentric distance, but that pantomime walking measures may suffer range compression. Depth extents along the ground are perceptually compressed relative to frontal ground extents in a manner consistent with the angular scale expansion hypothesis. PMID:22889186

  3. Fast depth decision for HEVC inter prediction based on spatial and temporal correlation

    NASA Astrophysics Data System (ADS)

    Chen, Gaoxing; Liu, Zhenyu; Ikenaga, Takeshi

    2016-07-01

    High efficiency video coding (HEVC) is a video compression standard that outperforms the predecessor H.264/AVC by doubling the compression efficiency. To enhance the compression accuracy, the partition sizes ranging is from 4x4 to 64x64 in HEVC. However, the manifold partition sizes dramatically increase the encoding complexity. This paper proposes a fast depth decision based on spatial and temporal correlation. Spatial correlation utilize the code tree unit (CTU) Splitting information and temporal correlation utilize the motion vector predictor represented CTU in inter prediction to determine the maximum depth in each CTU. Experimental results show that the proposed method saves about 29.1% of the original processing time with 0.9% of BD-bitrate increase on average.

  4. Chest Compression With Personal Protective Equipment During Cardiopulmonary Resuscitation: A Randomized Crossover Simulation Study.

    PubMed

    Chen, Jie; Lu, Kai-Zhi; Yi, Bin; Chen, Yan

    2016-04-01

    Following a chemical, biological, radiation, and nuclear incident, prompt cardiopulmonary resuscitation (CPR) procedure is essential for patients who suffer cardiac arrest. But CPR when wearing personal protection equipment (PPE) before decontamination becomes a challenge for healthcare workers (HCW). Although previous studies have assessed the impact of PPE on airway management, there is little research available regarding the quality of chest compression (CC) when wearing PPE.A present randomized cross-over simulation study was designed to evaluate the effect of PPE on CC performance using mannequins.The study was set in one university medical center in the China.Forty anesthesia residents participated in this randomized cross-over study.Each participant performed 2 min of CC on a manikin with and without PPE, respectively. Participants were randomized into 2 groups that either performed CC with PPE first, followed by a trial without PPE after a 180-min rest, or vice versa.CPR recording technology was used to objectively quantify the quality of CC. Additionally, participants' physiological parameters and subjective fatigue score values were recorded.With the use of PPE, a significant decrease of the percentage of effective compressions (41.3 ± 17.1% with PPE vs 67.5 ± 15.6% without PPE, P < 0.001) and the percentage of adequate compressions (67.7 ± 18.9% with PPE vs 80.7 ± 15.5% without PPE, P < 0.001) were observed. Furthermore, the increases in heart rate, mean arterial pressure, and subjective fatigue score values were more obvious with the use of PPE (all P < 0.01).We found significant deterioration of CC performance in HCW with the use of a level-C PPE, which may be a disadvantage for enhancing survival of cardiac arrest.

  5. Use of impedance threshold device in conjunction with our novel adhesive glove device for ACD-CPR does not result in additional chest decompression.

    PubMed

    Shih, Andre; Udassi, Sharda; Porvasnik, Stacy L; Lamb, Melissa A; Badugu, Srinivasarao; Venkata, Giridhar Kaliki; Lopez-Colon, Dalia; Haque, Ikram U; Zaritsky, Arno L; Udassi, Jai P

    2013-10-01

    To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. Controlled, randomized animal study. In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Acupuncture therapy related cardiac injury.

    PubMed

    Li, Xue-feng; Wang, Xian

    2013-12-01

    Cardiac injury is the most serious adverse event in acupuncture therapy. The causes include needling chest points near the heart, the cardiac enlargement and pericardial effusion that will enlarge the projected area on the body surface and make the proper depth of needling shorter, and the incorrect needling method of the points. Therefore, acupuncture practitioners must be familiar with the points of the heart projected area on the chest and the correct needling methods in order to reduce the risk of acupuncture therapy related cardiac injury.

  7. Blood Pressure and Coronary Perfusion Pressure Targeted Cardiopulmonary Resuscitation Improves 24-Hour Survival from Ventricular Fibrillation Cardiac Arrest

    PubMed Central

    Maryam, Y.; Sutton, Robert M.; Friess, Stuart H.; Bratinov, George; Bhalala, Utpal; Kilbaugh, Todd J.; Lampe, Joshua; Nadkarni, Vinay M.; Becker, Lance B.; Berg, Robert A.

    2016-01-01

    Objective Treatment algorithms for cardiac arrest are rescuer-centric and vary little from patient to patient. The objective of this study was to determine if cardiopulmonary resuscitation (CPR) targeted to arterial blood pressure and coronary perfusion pressure (CPP) rather than optimal Guideline Care would improve 24-hour survival in a porcine model of ventricular fibrillation (VF) cardiac arrest. Design Randomized interventional study Setting Preclinical animal laboratory Subjects Female 3-month old swine Interventions/Measurements After induction of anesthesia and 7 minutes of untreated VF, 16 female 3-month old swine were randomized to: 1) Blood Pressure (BP) care: titration of chest compression (CC) depth to a systolic blood pressure (SBP) of 100 mmHg and vasopressor dosing to maintain CPP >20mmHg or 2) Guideline care: CC depth targeted to 51 mm and standard Guideline vasopressor dosing. Animals received manual CPR for 10 minutes before the first defibrillation attempt and standardized post-resuscitation care for 24 hours. Main Results 24-hour survival was more likely with BP care versus Guideline care (0/8 versus 5/8, p<0.03), and all survivors had normal neurological examinations. Mean CPP prior to defibrillation was significantly higher with BP care (28±3 mmHg versus 10±6 mmHg, p<0.01). CC depth was lower with BP care (48±0.4 mmHg versus 44±0.5 mmHg, p<0.05) and number of vasopressor doses was higher with BP care (median 3 [range 1-7] versus 2 [range 2-2], p<0.01). Conclusions Individualized goal-directed hemodynamic resuscitation targeting SBP of 100 mmHg and CPP >20 mmHg improved 24-hour survival compared to Guideline care in this model of VF cardiac arrest. PMID:27414479

  8. [Sleeve resection of right main bronchus for posttraumatic bronchial stenosis].

    PubMed

    Bobocea, Andrei Cristian; Matache, Radu; Codreşi, Mihaela; Bolca, Ciprian; Cordoş, Ioan

    2011-01-01

    Tracheobronchial disruption is one of the most severe injuries caused by blunt chest trauma. A high index of clinical suspicion and accurate interpretation of radiological findings are necessary for prompt surgical intervention with primary repair of the airway. Delays in treatment increases the risk of partial to complete bronchial stenosis. A 21 years old male was admitted to our hospital following a workplace accident. A chest radiograph showed bilateral pneumothorax, cephalic and mediastinal emphysema. Chest tubes were placed on each side, with full pulmonary expansion and remission of emphysema. Minimal lesions of the right main bronchus were found at fiberoptic bronchoscopy. Daily chest X-rays showed an uncomplicated recovery. A stenosis was suspected due to right lung pneumonia evolving under specific antibiotherapy. Right main bronchus posttraumatic stricture was diagnosed by fiberoptic bronchoscopy. He underwent a right lateral thoracotomy with sleeve resection of stenotic bronchi. Control bronchoscopy reveals main bronchus widely patent with untraceable suture line. Main bronchus rupture in blunt chest trauma is an additive effect of chest wall compression between two solid surfaces, traction on the carina and sudden increase in intraluminal pressure. Symptoms may vary: soft air leak, pneumothorax or limited mediastinal emphysema. Bronchoscopy should be performed immediately or when available. Granulation tissue leads to progressive bronchial obstruction, with distal infection and permanent parenchymal damage. Sleeve resection of the stenosed segment is the treatment of choice and restores fully the lung function. Rupture of main bronchus is a complication of blunt chest trauma. Flexible bronchoscopy is useful and reliable for early diagnosis of traumatic tracheobronchial injuries. Delayed diagnosis can lead to lung parenchyma alteration due to retrostenotic pneumonia. Resection and end-to-end anastomosis is the key of successful in these cases.

  9. Three-dimensional automatic computer-aided evaluation of pleural effusions on chest CT images

    NASA Astrophysics Data System (ADS)

    Bi, Mark; Summers, Ronald M.; Yao, Jianhua

    2011-03-01

    The ability to estimate the volume of pleural effusions is desirable as it can provide information about the severity of the condition and the need for thoracentesis. We present here an improved version of an automated program to measure the volume of pleural effusions using regular chest CT images. First, the lungs are segmented using region growing, mathematical morphology, and anatomical knowledge. The visceral and parietal layers of the pleura are then extracted based on anatomical landmarks, curve fitting and active contour models. The liver and compressed tissues are segmented out using thresholding. The pleural space is then fitted to a Bezier surface which is subsequently projected onto the individual two-dimensional slices. Finally, the volume of the pleural effusion is quantified. Our method was tested on 15 chest CT studies and validated against three separate manual tracings. The Dice coefficients were 0.74+/-0.07, 0.74+/-0.08, and 0.75+/-0.07 respectively, comparable to the variation between two different manual tracings.

  10. Twyman effect mechanics in grinding and microgrinding.

    PubMed

    Lambropoulos, J C; Xu, S; Fang, T; Golini, D

    1996-10-01

    In the Twyman effect (1905), when one side of a thin plate with both sides polished is ground, the plate bends: The ground side becomes convex and is in a state of compressive residual stress, described in terms of force per unit length (Newtons per meter) induced by grinding, the stress (Newtons per square meter) induced by grinding, and the depth of the compressive layer (micrometers). We describe and correlate experiments on optical glasses from the literature in conditions of loose abrasive grinding (lapping at fixed nominal pressure, with abrasives 4-400 μm in size) and deterministic microgrinding experiments (at a fixed infeed rate) conducted at the Center for Optics Manufacturing with bound diamond abrasive tools (with a diamond size of 3-40 μm, embedded in metallic bond) and loose abrasive microgrinding (abrasives of less than 3 μm in size). In brittle grinding conditions, the grinding force and the depth of the compressive layer correlate well with glass mechanical properties describing the fracture process, such as indentation crack size. The maximum surface residual compressive stress decreases, and the depth of the compressive layer increases with increasing abrasive size. In lapping conditions the depth of the abrasive grain penetration into the glass surface scales with the surface roughness, and both are determined primarily by glass hardness and secondarily by Young's modulus for various abrasive sizes and coolants. In the limit of small abrasive size (ductile-mode grinding), the maximum surface compressive stress achieved is near the yield stress of the glass, in agreement with finite-element simulations of indentation in elastic-plastic solids.

  11. Google Glass for Residents Dealing With Pediatric Cardiopulmonary Arrest: A Randomized, Controlled, Simulation-Based Study.

    PubMed

    Drummond, David; Arnaud, Cécile; Guedj, Romain; Duguet, Alexandre; de Suremain, Nathalie; Petit, Arnaud

    2017-02-01

    To determine whether real-time video communication between the first responder and a remote intensivist via Google Glass improves the management of a simulated in-hospital pediatric cardiopulmonary arrest before the arrival of the ICU team. Randomized controlled study. Children's hospital at a tertiary care academic medical center. Forty-two first-year pediatric residents. Pediatric residents were evaluated during two consecutive simulated pediatric cardiopulmonary arrests with a high-fidelity manikin. During the second evaluation, the residents in the Google Glass group were allowed to seek help from a remote intensivist at any time by activating real-time video communication. The residents in the control group were asked to provide usual care. The main outcome measures were the proportion of time for which the manikin received no ventilation (no-blow fraction) or no compression (no-flow fraction). In the first evaluation, overall no-blow and no-flow fractions were 74% and 95%, respectively. During the second evaluation, no-blow and no-flow fractions were similar between the two groups. Insufflations were more effective (p = 0.04), and the technique (p = 0.02) and rate (p < 0.001) of chest compression were more appropriate in the Google Glass group than in the control group. Real-time video communication between the first responder and a remote intensivist through Google Glass did not decrease no-blow and no-flow fractions during the first 5 minutes of a simulated pediatric cardiopulmonary arrest but improved the quality of the insufflations and chest compressions provided.

  12. The primacy of basics in advanced life support.

    PubMed

    Chamberlain, Douglas; Frenneaux, Michael; Fletcher, David

    2009-06-01

    The standards required for optimal effect of chest compressions and the degree to which most practice falls short of ideal have not been widely appreciated. This review highlights some of the important data now available and offers a haemodynamic explanation that broadens current concepts. New techniques have permitted a detailed examination of how compressions are performed in practice. The implications of recent experimental work adds a new imperative to the need for improvement. In addition to highlighting the need for improved training and audit, the greater understanding of mechanisms in resuscitation suggest that guidelines for management of adult cardiac arrest of presumed cardiac origin need further revision and simplification.

  13. High-speed reconstruction of compressed images

    NASA Astrophysics Data System (ADS)

    Cox, Jerome R., Jr.; Moore, Stephen M.

    1990-07-01

    A compression scheme is described that allows high-definition radiological images with greater than 8-bit intensity resolution to be represented by 8-bit pixels. Reconstruction of the images with their original intensity resolution can be carried out by means of a pipeline architecture suitable for compact, high-speed implementation. A reconstruction system is described that can be fabricated according to this approach and placed between an 8-bit display buffer and the display's video system thereby allowing contrast control of images at video rates. Results for 50 CR chest images are described showing that error-free reconstruction of the original 10-bit CR images can be achieved.

  14. 3D video coding: an overview of present and upcoming standards

    NASA Astrophysics Data System (ADS)

    Merkle, Philipp; Müller, Karsten; Wiegand, Thomas

    2010-07-01

    An overview of existing and upcoming 3D video coding standards is given. Various different 3D video formats are available, each with individual pros and cons. The 3D video formats can be separated into two classes: video-only formats (such as stereo and multiview video) and depth-enhanced formats (such as video plus depth and multiview video plus depth). Since all these formats exist of at least two video sequences and possibly additional depth data, efficient compression is essential for the success of 3D video applications and technologies. For the video-only formats the H.264 family of coding standards already provides efficient and widely established compression algorithms: H.264/AVC simulcast, H.264/AVC stereo SEI message, and H.264/MVC. For the depth-enhanced formats standardized coding algorithms are currently being developed. New and specially adapted coding approaches are necessary, as the depth or disparity information included in these formats has significantly different characteristics than video and is not displayed directly, but used for rendering. Motivated by evolving market needs, MPEG has started an activity to develop a generic 3D video standard within the 3DVC ad-hoc group. Key features of the standard are efficient and flexible compression of depth-enhanced 3D video representations and decoupling of content creation and display requirements.

  15. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

    PubMed

    Sitzwohl, Christian; Langheinrich, Angelika; Schober, Andreas; Krafft, Peter; Sessler, Daniel I; Herkner, Harald; Gonano, Christopher; Weinstabl, Christian; Kettner, Stephan C

    2010-11-09

    To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity. Prospective randomised blinded study. Department of anaesthesia in tertiary academic hospital. 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery. Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three). Correct and incorrect judgments of endotracheal tube position. 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (P<0.001). The four tested methods had the same specificity for ruling out endobronchial intubation (that is, confirming correct tracheal intubation). The average correct tube insertion depth was 21 cm in women and 23 cm in men. By inserting the tube to these distances, however, the distal tip of the tube was less than 2.5 cm away from the carina (the recommended safety distance, to prevent inadvertent endobronchial intubation with changes in the position of the head in intubated patients) in 20% (24/118) of women and 18% (7/42) of men. Therefore optimal tube insertion depth was considered to be 20 cm in women and 22 cm in men. Less experienced clinicians should rely more on tube insertion depth than on auscultation to detect inadvertent endobronchial intubation. But even experienced physicians will benefit from inserting tubes to 20-21 cm in women and 22-23 cm in men, especially when high ambient noise precludes accurate auscultation (such as in emergency situations or helicopter transport). The highest sensitivity and specificity for ruling out endobronchial intubation, however, is achieved by combining tube depth, auscultation of the lungs, and observation of symmetrical chest movements. NCT01232166.

  16. High frequency chest wall compression and carbon dioxide elimination in obstructed dogs.

    PubMed

    Gross, D; Vartian, V; Minami, H; Chang, H K; Zidulka, A

    1984-01-01

    High frequency chest wall compression (HFCWC) was studied as a method of assisting ventilation in six spontaneously breathing anesthetized dogs. Under a constant level of anesthesia, the dogs became hypercapneic after airflow obstruction was created by metal beads inserted in the airways. HFCWC was achieved by a piston pump rapidly oscillating the pressure in a modified double blood pressure cuff wrapped around the lower thorax. Thirty minute periods of spontaneous ventilation were alternated with thirty minute periods of spontaneous breathing plus HFCWC at 3, 5 or 8 Hz. The superimposition of HFCWC to spontaneous ventilation resulted in little change in the PaO2. The PaCO2, however, was reduced in every case from a mean of 6.55 +/- 0.59 to 4.72 +/- 0.32 kPa at 3 Hz (p less than 0.05), 6.92 +/- 0.57 to 3.9 +/- 0.45 kPa at 5 Hz (p less than 0.01) and 7.10 +/- 0.65 to 4.56 +/- 0.59 kPa at 8 Hz (p less than 0.05). This occurred despite a decrease in spontaneous minute ventilation. We conclude that HFCWC can assist in elimination of CO2 in obstructed spontaneous breathing dogs with hypercapnea.

  17. Comprehensive cardiopulmonary life support (CCLS) for cardiopulmonary resuscitation by trained paramedics and medics inside the hospital

    PubMed Central

    Garg, Rakesh; Ahmed, Syed Moied; Kapoor, Mukul Chandra; Rao, SSC Chakra; Mishra, Bibhuti Bhusan; Kalandoor, M Venkatagiri; Singh, Baljit; Divatia, Jigeeshu Vasishtha

    2017-01-01

    The cardiopulmonary resuscitation (CPR) guideline of comprehensive cardiopulmonary life support (CCLS) for management of the patient with cardiopulmonary arrest in adults provides an algorithmic step-wise approach for optimal outcome of the patient inside the hospital by trained medics and paramedics. This guideline has been developed considering the infrastructure of healthcare delivery system in India. This is based on evidence in the international and national literature. In the absence of data from the Indian population, the extrapolation has been made from international data, discussed with Indian experts and modified accordingly to ensure their applicability in India. The CCLS guideline emphasise the need to recognise patients at risk for cardiac arrest and their timely management before a cardiac arrest occurs. The basic components of CPR include chest compressions for blood circulation; airway maintenance to ensure airway patency; lung ventilation to enable oxygenation and defibrillation to convert a pathologic ‘shockable’ cardiac rhythm to one capable to maintaining effective blood circulation. CCLS emphasises incorporation of airway management, drugs, and identification of the cause of arrest and its correction, while chest compression and ventilation are ongoing. It also emphasises the value of organised team approach and optimal post-resuscitation care. PMID:29217853

  18. Intergenerational changes in chest size and proportions in children and adolescents aged 3-18 from Kraków (Poland), within the last 70 years.

    PubMed

    Kryst, Łukasz; Woronkowicz, Agnieszka; Kowal, Małgorzata; Sobiecki, Jan

    2017-03-01

    The size and proportions of the human body change continuously in response to social change and economic development. As reported by papers on intergenerational changes in chest size, this part of the human body is also influenced by environmental factors. The aim of this study was to assess changes in the dimensions and proportions of the chest of children and adolescents over a span of 70 years. In 2010 an anthropological study was conducted on 3878 children and adolescents aged 3-18 years living in Kraków (Poland). Data on chest dimensions (breadth, depth, circumference, chest index) were compared to data from 1938 (3719 children) and 1983 (6464 children). In boys, chests became increasingly deep; in boys 18 years of age, the chest index increased by 4.8 units, unlike girls, whose chests markedly flattened. The chest index in girls 18 years of age decreased by 4.2 units. In almost all age categories these differences were statistically significant. Also, in all age categories, children studied in 2010 had a significantly bigger chest circumference than boys and girls surveyed in 1983, respectively, by averages of 3.6 cm and 3 cm. The main reason for these changes may be the socio-economic transformation, which has been especially strong in recent decades. These results may have practical importance in many areas of knowledge, including medicine, nutritional science, and sports. They can also be important for informing preventive measures that should be taken in order to increase the physical activity of children and youth, especially boys. © 2016 Wiley Periodicals, Inc.

  19. Distribution and determinants of QRS rotation of black and white persons in the general population.

    PubMed

    Prineas, Ronald J; Zhang, Zhu-Ming; Stevens, Cladd E; Soliman, Elsayed Z

    The prevalence and determinants of QRS transition zones are not well established. We examined the distributions of Normal, clockwise (CW) and counterclockwise (CCW)) QRS transition zones and their relations to disease, body size and demographics in 4624 black and white men and women free of cardiovascular disease and major ECG abnormalities enrolled in the NHANES-III survey. CW transition zones were least observed (6.2%) and CCW were most prevalent (60.1%) with Normal in an intermediate position (33.7%). In multivariable logistic regression analysis, the adjusted, significant predictors for CCW compared to Normal were a greater proportion of blacks and women, fewer thin people (BMI<20, thin), a greater ratio of chest depth to chest width, and an LVMass index <80g. By contrast, CW persons were older, had larger QRS/T angles, smaller ratio of chest depth to chest width, had a greater proportion of subjects with low voltage QRS, more pulmonary disease, a greater proportion with high heart rates, shorter QRS duration and were more obese (BMI≥30). Normal rather than being the most prevalent transition zone was intermediate in frequency between the most frequently encountered CCW and the least frequently encountered transition zone CW. Differences in the predictors of CW and CCW exist. This requires further investigation to examine how far these differences explain the differences in the published prognostic differences between CW and CCW. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Profound Obstructive Hypotension From Prone Positioning Documented by Transesophageal Echocardiography in a Patient With Scoliosis: A Case Report.

    PubMed

    Abcejo, Arnoley S; Diaz Soto, Juan; Castoro, Courtney; Armour, Sarah; Long, Timothy R

    2017-08-01

    In a healthy 12-year-old female with scoliosis, prone positioning resulted in pressor-refractory cardiovascular collapse. Resumption of supine position immediately improved hemodynamics. Intraoperative transesophageal echocardiography (TEE) revealed a collapsed left atrium and biventricular failure. Repeat prone positioning resulted in a recurrence of hypotension. However, hemodynamic stabilization was restored and maintained by repositioning chest pads caudally. The patient successfully underwent a 6-hour scoliosis repair without perioperative morbidity. With this case, we aim to: (1) reintroduce awareness of this mechanical obstructive cause of reversible hypotension; (2) highlight the use of intraoperative TEE during prone hemodynamic collapse; and (3) suggest an alternative prone positioning technique if chest compression results in hemodynamic instability.

  1. Elastic plate flexure above mantle plumes explains the upstream offset of volcanic activity at la Réunion and Hawaii

    NASA Astrophysics Data System (ADS)

    Gerbault, Muriel; Fontaine, Fabrice; Rabinowicz, Michel; Bystricky, Micha

    2017-04-01

    Surface volcanism at la Réunion and Hawaii occurs with an offset of 150-180 km upstream to the plume axis with respect to the plate motion. This striking observation raises questions about the forcing of plume-lithosphere thermo-mechanical interactions on melt trajectories beneath these islands. Based on visco-elasto-plastic numerical models handled at kilometric resolution, we propose to explain this offset by the development of compressional stresses at the base of the lithosphere, that result from elastic plate bending above the upward load exerted by the plume head. This horizontal compression adopts a disc shape centered around the plume axis, 20 km thick and 150 km in radius, at 50-70 km depth where the temperature varies from 600°C to 750°C. It lasts for 5 to 10 My in an oceanic plate of age greater than 70 My, a timing that is controlled by the visco-elastic relaxation time at 50-70 km depth. This period of time exceeds the time during which both the Somalian/East-African and Pacific plates drift over the Reunion and Hawaii plumes, respectively, thus rendering this basal compression a persistent feature. It is inferred that the buoyant melts percolating in the plume head pond below this zone of compression and eventually spread laterally until the most compressive principal elastic stresses reverse to the vertical, i.e., 150 km away from the plume head. There, melts propagate through dikes upwards to 35 km depth, where the plate curvature reverses and ambient compression diminishes. This 30-35 km depth may thus host magmatic reservoirs where melts pond, until further differentiation can relaunch ascension up to the surface and form a volcanic edifice. In a second stage, as the volcano grows because of melt accumulation at the top of the plate, the lithosphere is flexed downwards, inducing extra tensile stress at 30-35 km depth and compression at 15 km depth. It implies that now the melts pond at 15 km and form another magmatic reservoir lying just underneath the crust. These two processes explain the ponding of primary (shield) melts at 35 km and 15 km depths as partialy recorded below La Reunion, Mauritius or Hawaii volcanoes with seismic tomography.

  2. Stress Study on Southern Segment of Longmenshan Fault Constrained by Focal Mechanism Data

    NASA Astrophysics Data System (ADS)

    Yang, Y.; Liang, C.; Su, J.; Zhou, L.

    2016-12-01

    The Longmenshan fault (LMSF) lies at the eastern margin of Tibetan plateau and constitutes the boundary of the active Bayankala block and rigid Sichuan basin. This fault was misinterpreted as an inactive fault before the great Wenchuan earthquake. Five years after the devastating event, the Lushan MS 7.0 stroke the southern segment of the LMSF but fractured in a very limited scale and formed a seismic gap between the two earthquakes. In this study, we determined focal mechanisms of earthquakes with magnitude M≥3 from Jan 2008 to July 2014 in the southern segment of LMSF, and then applied the damped linear inversion to derive the regional stress field based on the focal mechanisms. Focal mechanisms of 755 earthquakes in total were determined. We further used a damped linear inversion technique to produce a 2D stress map in upper crust in the study region. A dominant thrust regime is determined south of the seismic gap, with a horizontal maximum compression oriented in NWW-SEE. But in the area to the north of the seismic gap is characterized as a much more complex stress environment. To the west of the Dujiangyan city, there appear to be a seismic gap in the Pengguan complex. The maximum compressions show the anti-clockwise and clockwise patterns to the south and north of this small gap. Thus the small gap seems to be an asperity that causes the maximum compression to rotate around it. While combined the maximum compression pattern with the focal solutions of strong earthquakes (Mw≥5) in this region, two of those strong earthquakes located near the back-range-fault have strikes parallel to the Miyaluo fault. Considering a large amount of earthquakes in Lixian branch, the Miyaluo fault may be extended to LMSF following the great Wenchuan earthquake. Investigations on the stress field of different depths indicate complex spatial variations. The Pengguan complex is almost aseismic in shallow depth in its central part. In deeper depth, the maximum compressions show the NNW-SSE and NE-SW directions to the north and south of the seismic gap respectively, this are surprisingly different from that of the shallower depth. Thus the maximum compressions vary with depth may imply the movement in depth is decoupled from the movement in shallow depth. This work was partially supported by National Natural Science Foundation of China (41340009).

  3. Cardiopulmonary Resuscitation Training of Family Members Before Hospital Discharge Using Video Self-Instruction: A Feasibility Trial

    PubMed Central

    Blewer, Audrey L.; Leary, Marion; Decker, Christopher S.; Andersen, James C.; Fredericks, Amanda C.; Bobrow, Bentley J.; Abella, Benjamin S.

    2014-01-01

    BACKGROUND Bystander cardiopulmonary resuscitation (CPR) is a crucial therapy for sudden cardiac arrest (SCA), yet rates of bystander CPR are low. This is especially the case for SCA occurring in the home setting, as family members of at-risk patients are often not CPR trained. OBJECTIVE To evaluate the feasibility of a novel hospital-based CPR education program targeted to family members of patients at increased risk for SCA. DESIGN Prospective, multicenter, cohort study. SETTING Inpatient wards at 3 hospitals. SUBJECTS Family members of inpatients admitted with cardiac-related diagnoses. MEASUREMENTS AND RESULTS Family members were offered CPR training via a proctored video-self instruction (VSI) program. After training, CPR skills and participant perspectives regarding their training experience were assessed. Surveys were conducted one month postdischarge to measure the rate of “secondary training” of other individuals by enrolled family members. At the 3 study sites, 756 subjects were offered CPR instruction; 280 agreed to training and 136 underwent instruction using the VSI program. Of these, 78 of 136 (57%) had no previous CPR training. After training, chest compression performance was generally adequate (mean compression rate 90 ± 26/minute, mean depth 37 ± 12 mm). At 1 month, 57 of 122 (47%) of subjects performed secondary training for friends or family members, with a calculated mean of 2.1 persons trained per kit distributed. CONCLUSIONS The hospital setting offers a unique “point of capture” to provide CPR instruction to an important, undertrained population in contact with at-risk individuals. PMID:21916007

  4. Brief compression-only cardiopulmonary resuscitation training video and simulation with homemade mannequin improves CPR skills.

    PubMed

    Wanner, Gregory K; Osborne, Arayel; Greene, Charlotte H

    2016-11-29

    Cardiopulmonary resuscitation (CPR) training has traditionally involved classroom-based courses or, more recently, home-based video self-instruction. These methods typically require preparation and purchase fee; which can dissuade many potential bystanders from receiving training. This study aimed to evaluate the effectiveness of teaching compression-only CPR to previously untrained individuals using our 6-min online CPR training video and skills practice on a homemade mannequin, reproduced by viewers with commonly available items (towel, toilet paper roll, t-shirt). Participants viewed the training video and practiced with the homemade mannequin. This was a parallel-design study with pre and post training evaluations of CPR skills (compression rate, depth, hand position, release), and hands-off time (time without compressions). CPR skills were evaluated using a sensor-equipped mannequin and two blinded CPR experts observed testing of participants. Twenty-four participants were included: 12 never-trained and 12 currently certified in CPR. Comparing pre and post training, the never-trained group had improvements in average compression rate per minute (64.3 to 103.9, p = 0.006), compressions with correct hand position in 1 min (8.3 to 54.3, p = 0.002), and correct compression release in 1 min (21.2 to 76.3, p < 0.001). The CPR-certified group had adequate pre and post-test compression rates (>100/min), but an improved number of compressions with correct release (53.5 to 94.7, p < 0.001). Both groups had significantly reduced hands-off time after training. Achieving adequate compression depths (>50 mm) remained problematic in both groups. Comparisons made between groups indicated significant improvements in compression depth, hand position, and hands-off time in never-trained compared to CPR-certified participants. Inter-rater agreement values were also calculated between the CPR experts and sensor-equipped mannequin. A brief internet-based video coupled with skill practice on a homemade mannequin improved compression-only CPR skills, especially in the previously untrained participants. This training method allows for widespread compression-only CPR training with a tactile learning component, without fees or advance preparation.

  5. Improving Hybrid III injury assessment in steering wheel rim to chest impacts using responses from finite element Hybrid III and human body model.

    PubMed

    Holmqvist, Kristian; Davidsson, Johan; Mendoza-Vazquez, Manuel; Rundberget, Peter; Svensson, Mats Y; Thorn, Stefan; Törnvall, Fredrik

    2014-01-01

    The main aim of this study was to improve the quality of injury risk assessments in steering wheel rim to chest impacts when using the Hybrid III crash test dummy in frontal heavy goods vehicle (HGV) collision tests. Correction factors for chest injury criteria were calculated as the model chest injury parameter ratios between finite element (FE) Hybrid III, evaluated in relevant load cases, and the Total Human Model for Safety (THUMS). This is proposed to be used to compensate Hybrid III measurements in crash tests where steering wheel rim to chest impacts occur. The study was conducted in an FE environment using an FE-Hybrid III model and the THUMS. Two impactor shapes were used, a circular hub and a long, thin horizontal bar. Chest impacts at velocities ranging from 3.0 to 6.0 m/s were simulated at 3 impact height levels. A ratio between FE-Hybrid III and THUMS chest injury parameters, maximum chest compression C max, and maximum viscous criterion VC max, were calculated for the different chest impact conditions to form a set of correction factors. The definition of the correction factor is based on the assumption that the response from a circular hub impact to the middle of the chest is well characterized and that injury risk measures are independent of impact height. The current limits for these chest injury criteria were used as a basis to develop correction factors that compensate for the limitations in biofidelity of the Hybrid III in steering wheel rim to chest impacts. The hub and bar impactors produced considerably higher C max and VC max responses in the THUMS compared to the FE-Hybrid III. The correction factor for the responses of the FE-Hybrid III showed that the criteria responses for the bar impactor were consistently overestimated. Ratios based on Hybrid III and THUMS responses provided correction factors for the Hybrid III responses ranging from 0.84 to 0.93. These factors can be used to estimate C max and VC max values when the Hybrid III is used in crash tests for which steering wheel rim to chest interaction occurs. For the FE-Hybrid III, bar impacts caused higher chest deflection compared to hub impacts, although the contrary results were obtained with the more humanlike THUMS. Correction factors were developed that can be used to correct the Hybrid III chest responses. Higher injury criteria capping limits for steering wheel impacts are acceptable. Supplemental materials are available for this article. Go to the publisher's online edition of Traffic Injury Prevention to view the supplemental file.

  6. Chest tomosynthesis: technical principles and clinical update.

    PubMed

    Dobbins, James T; McAdams, H Page

    2009-11-01

    Digital tomosynthesis is a radiographic technique that can produce an arbitrary number of section images of a patient from a single pass of the X-ray tube. It utilizes a conventional X-ray tube, a flat-panel detector, a computer-controlled tube mover, and special reconstruction algorithms to produce section images. While it does not have the depth resolution of computed tomography (CT), tomosynthesis provides some of the tomographic benefits of CT but at lower cost and radiation dose than CT. Compared to conventional chest radiography, chest tomosynthesis results in improved visibility of normal structures such as vessels, airway and spine. By reducing visual clutter from overlying normal anatomy, it also enhances detection of small lung nodules. This review article outlines the components of a tomosynthesis system, discusses results regarding improved lung nodule detection from the recent literature, and presents examples of nodule detection from a clinical trial in human subjects. Possible implementation strategies for use in clinical chest imaging are discussed.

  7. Altered Standards of Care: An Analysis of Existing Federal, State, and Local Guidelines

    DTIC Science & Technology

    2011-12-01

    Approved for public release; distribution is unlimited 12b. DISTRIBUTION CODE A 13. ABSTRACT (maximum 200 words ) A...data systems for communications and the transference of data. Losing data systems during disasters cuts off access to electronic medical records...emergency procedures as mouth - to- mouth resuscitation, external chest compression, electric shock, insertion of a tube to open the patient’s airway

  8. Atypical autoerotic deaths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gowitt, G.T.; Hanzlick, R.L.

    1992-06-01

    So-called typical' autoerotic fatalities are the result of asphyxia due to mechanical compression of the neck, chest, or abdomen, whereas atypical' autoeroticism involves sexual self-stimulation by other means. The authors present five atypical autoerotic fatalities that involved the use of dichlorodifluoromethane, nitrous oxide, isobutyl nitrite, cocaine, or compounds containing 1-1-1-trichloroethane. Mechanisms of death are discussed in each case and the pertinent literature is reviewed.

  9. Quality of basic life support when using different commercially available public access defibrillators.

    PubMed

    Müller, Michael P; Poenicke, Cynthia; Kurth, Maxi; Richter, Torsten; Koch, Thea; Eisold, Carolin; Pfältzer, Adrian; Heller, Axel R

    2015-06-21

    Basic life support (BLS) guidelines focus on chest compressions with a minimal no-flow fraction (NFF), early defibrillation, and a short perishock pause. By using an automated external defibrillator (AED) lay persons are guided through the process of attaching electrodes and initiating defibrillation. It is unclear, however, to what extent the voice instructions given by the AED might influence the quality of initial resuscitation. Using a patient simulator, 8 different commercially available AEDs were evaluated within two different BLS scenarios (ventricular fibrillation vs. asystole). A BLS certified instructor acted according to the current European Resuscitation Council 2010 Guidelines and followed all of the AED voice prompts. In a second set of scenarios, the rescuer anticipated the appropriate actions and started already before the AED stopped speaking. A BLS scenario without AED served as the control. All scenarios were run three times. The time until the first chest compression was 25 ± 2 seconds without the AED and ranged from 50 ± 3 to 148 ± 13 seconds with the AED depending on the model used. The NFF was .26 ± .01 without the AED and between .37 ± .01 and .72 ± .01 when an AED was used. The perishock pause ranged from 12 ± 0 to 46 ± 0 seconds. The optimized sequence of actions reduced the NFF, which ranged now from .32 ± .01 to .41 ± .01, and the perishock pause ranging from 1 ± 1 to 19 ± 1 seconds. Voice prompts given by commercially available AED merely meet the requirements of current evidence in basic life support. Furthermore, there is a significant difference between devices with regard to time until the first chest compression, perishock pause, no-flow fraction and other objective measures of the quality of BLS. However, the BLS quality may be improved with optimized handling of the AED. Thus, rescuers should be trained on the respective AED devices, and manufacturers should expend more effort in improving user guidance to shorten the NFF and perishock pause.

  10. Standardized model of porcine resuscitation using a custom-made resuscitation board results in optimal hemodynamic management.

    PubMed

    Wollborn, Jakob; Ruetten, Eva; Schlueter, Bjoern; Haberstroh, Joerg; Goebel, Ulrich; Schick, Martin A

    2018-01-22

    Standardized modeling of cardiac arrest and cardiopulmonary resuscitation (CPR) is crucial to evaluate new treatment options. Experimental porcine models are ideal, closely mimicking human-like physiology. However, anteroposterior chest diameter differs significantly, being larger in pigs and thus poses a challenge to achieve adequate perfusion pressures and consequently hemodynamics during CPR, which are commonly achieved during human resuscitation. The aim was to prove that standardized resuscitation is feasible and renders adequate hemodynamics and perfusion in pigs, using a specifically designed resuscitation board for a pneumatic chest compression device. A "porcine-fit" resuscitation board was designed for our experiments to optimally use a pneumatic compression device (LUCAS® II, Physio-Control Inc.), which is widely employed in emergency medicine and ideal in an experimental setting due to its high standardization. Asphyxial cardiac arrest was induced in 10 German hybrid landrace pigs and cardiopulmonary resuscitation was performed according to ERC/AHA 2015 guidelines with mechanical chest compressions. Hemodynamics were measured in the carotid and pulmonary artery. Furthermore, arterial blood gas was drawn to assess oxygenation and tissue perfusion. The custom-designed resuscitation board in combination with the LUCAS® device demonstrated highly sufficient performance regarding hemodynamics during CPR (mean arterial blood pressure, MAP 46 ± 1 mmHg and mean pulmonary artery pressure, mPAP of 36 ± 1 mmHg over the course of CPR). MAP returned to baseline values at 2 h after ROSC (80 ± 4 mmHg), requiring moderate doses of vasopressors. Furthermore, stroke volume and contractility were analyzed using pulse contour analysis (106 ± 3 ml and 1097 ± 22 mmHg/s during CPR). Blood gas analysis revealed CPR-typical changes, normalizing in the due course. Thermodilution parameters did not show persistent intravascular volume shift. Standardized cardiopulmonary resuscitation is feasible in a porcine model, achieving adequate hemodynamics and consecutive tissue perfusion of consistent quality. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Extreme compression for extreme conditions: pilot study to identify optimal compression of CT images using MPEG-4 video compression.

    PubMed

    Peterson, P Gabriel; Pak, Sung K; Nguyen, Binh; Jacobs, Genevieve; Folio, Les

    2012-12-01

    This study aims to evaluate the utility of compressed computed tomography (CT) studies (to expedite transmission) using Motion Pictures Experts Group, Layer 4 (MPEG-4) movie formatting in combat hospitals when guiding major treatment regimens. This retrospective analysis was approved by Walter Reed Army Medical Center institutional review board with a waiver for the informed consent requirement. Twenty-five CT chest, abdomen, and pelvis exams were converted from Digital Imaging and Communications in Medicine to MPEG-4 movie format at various compression ratios. Three board-certified radiologists reviewed various levels of compression on emergent CT findings on 25 combat casualties and compared with the interpretation of the original series. A Universal Trauma Window was selected at -200 HU level and 1,500 HU width, then compressed at three lossy levels. Sensitivities and specificities for each reviewer were calculated along with 95 % confidence intervals using the method of general estimating equations. The compression ratios compared were 171:1, 86:1, and 41:1 with combined sensitivities of 90 % (95 % confidence interval, 79-95), 94 % (87-97), and 100 % (93-100), respectively. Combined specificities were 100 % (85-100), 100 % (85-100), and 96 % (78-99), respectively. The introduction of CT in combat hospitals with increasing detectors and image data in recent military operations has increased the need for effective teleradiology; mandating compression technology. Image compression is currently used to transmit images from combat hospital to tertiary care centers with subspecialists and our study demonstrates MPEG-4 technology as a reasonable means of achieving such compression.

  12. Videographic assessment of cardiopulmonary resuscitation quality in the pediatric emergency department.

    PubMed

    Donoghue, Aaron; Hsieh, Ting-Chang; Myers, Sage; Mak, Allison; Sutton, Robert; Nadkarni, Vinay

    2015-06-01

    To describe the adherence to guidelines for CPR in a tertiary pediatric emergency department (ED) where resuscitations are reviewed by videorecording. Resuscitations in a tertiary pediatric ED are videorecorded as part of a quality improvement project. Patients receiving CPR under videorecorded conditions were eligible for inclusion. CPR parameters were quantified by retrospective review. Data were described by 30-s epoch (compression rate, ventilation rate, compression:ventilation ratio), by segment (duration of single providers' compressions) and by overall event (compression fraction). Duration of interruptions in compressions was measured; tasks completed during pauses were tabulated. 33 children received CPR under videorecorded conditions. A total of 650 min of CPR were analyzed. Chest compressions were performed at <100/min in 90/714 (13%) of epochs; 100-120/min in 309/714 (43%); >120/min in 315/714 (44%). Ventilations were 6-12 breaths/min in 201/708 (23%) of epochs and >12/min in 489/708 (70%). During CPR without an artificial airway, compression:ventilation coordination (15:2) was done in 93/234 (40%) of epochs. 178 pauses in CPR occurred; 120 (67%) were <10s in duration. Of 370 segments of compressions by individual providers, 282/370 (76%) were <2 min in duration. Median compression fraction was 91% (range 88-100%). CPR in a tertiary pediatric ED frequently met recommended parameters for compression rate, pause duration, and compression fraction. Hyperventilation and failure of C:V coordination were very common. Future studies should focus on the impact of training methods on CPR performance as documented by videorecording. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Acute spinal cord compression: a rare complication of dual antiplatelet therapy

    PubMed Central

    Iskandar, Muhammad Zaid; Chong, Victor; Hutcheon, Stuart

    2015-01-01

    A 73-year-old woman presented with acute shortness of breath and exacerbation of chronic back pain. She was diagnosed with pulmonary oedema and a non-ST-elevation myocardial infarction following chest X-ray, ECG and high sensitivity troponin levels. She subsequently underwent coronary angioplasty with deployment of drug-eluting stents to her circumflex and left anterior descending arteries and was started on aspirin and clopidogrel for her dual antiplatelet therapy. Unfortunately, following the procedure, she gradually lost power and sensation in both lower limbs. MRI of her spine confirmed an extradural haematoma causing thoracic cord compression. She was managed conservatively following discussions with neurosurgeons and developed further complications secondary to her immobility. PMID:26202314

  14. [Features of cranio-cerebral trauma in victims of road accidents].

    PubMed

    Ogleznev, K Ia; Stankevich, P V

    2001-01-01

    The paper deals with the specific features of brain injury (BI) in victims of road traffic accidents (RTA). RTA victims are most commonly pedestrians (62.6%) and less commonly drivers (17.5%). In over half the cases (62.6%), BI due to RTA is associated with extracranial lesions, leading to diagnostic problems. The pattern and site of lesions are related to the type of a transport vehicle and to the role of a victim as a traffic participant. Multiple extracranial lesions are mostly frequently encountered in victim pedestrians (30.3%), BI concurrent with chest damage is common in drivers (12.8%), BI concurrent with "whip" injury of the cervical spine is found in drivers and passengers though such combinations may also seen in pedestrians (1.5%--5 cases). The most severe form of brain compression is multifactorial compression (27.6%) and its most common form is compression with subdural hematoma (35.3%).

  15. Asymptomatic Presentation of Large Cardiac Hydatid.

    PubMed

    Beedkar, Amey; Parikh, Rohan; Deshmukh, Pradeep

    2017-02-01

    Hydatid cyst is a tissue parasitic infection caused by tapeworm Echinococcus granulosus. Common location for hydatid cysts are the liver (65%) and the lungs (25%). Cardiac hydatid cyst is seen rarely, occurring in about 0.5-2% of all cases of hydatid disease. We present this case of 45 years female who presented with short duration of dry cough and atypical chest pain. Chest X ray showed cardiomegaly with round bulge at the right heart border and curvilinear calcification in left upper abdomen in the region of spleen. Transthoracic echocardiography (TTE) depicted cystic lesion in Right Ventricle free wall causing compression of right atrial and ventricular cavity. Cardiac CT confirmed this cyst as hydatid cyst. Patient underwent successful excision of right ventricular hydatid cyst. © Journal of the Association of Physicians of India 2011.

  16. Nineth Rib Syndrome after 10(th) Rib Resection.

    PubMed

    Yu, Hyun Jeong; Jeong, Yu Sub; Lee, Dong Hoon; Yim, Kyoung Hoon

    2016-07-01

    The 12(th) rib syndrome is a disease that causes pain between the upper abdomen and the lower chest. It is assumed that the impinging on the nerves between the ribs causes pain in the lower chest, upper abdomen, and flank. A 74-year-old female patient visited a pain clinic complaining of pain in her back, and left chest wall at a 7 on the 0-10 Numeric Rating scale (NRS). She had a lateral fixation at T12-L2, 6 years earlier. After the operation, she had multiple osteoporotic compression fractures. When the spine was bent, the patient complained about a sharp pain in the left mid-axillary line and radiating pain toward the abdomen. On physical examination, the 10(th) rib was not felt, and an image of the rib-cage confirmed that the left 10(th) rib was severed. When applying pressure from the legs to the 9(th) rib of the patient, pain was reproduced. Therefore, the patient was diagnosed with 9(th) rib syndrome, and ultrasound-guided 9(th) and 10(th) intercostal nerve blocks were performed around the tips of the severed 10(th) rib. In addition, local anesthetics with triamcinolone were administered into the muscles beneath the 9(th) rib at the point of the greatest tenderness. The patient's pain was reduced to NRS 2 point. In this case, it is suspected that the patient had a partial resection of the left 10(th) rib in the past, and subsequent compression fractures at T8 and T9 led to the deformation of the rib cage, causing the tip of the remaining 10(th) rib to impinge on the 9(th) intercostal nerves, causing pain.

  17. GPU-accelerated compressed-sensing (CS) image reconstruction in chest digital tomosynthesis (CDT) using CUDA programming

    NASA Astrophysics Data System (ADS)

    Choi, Sunghoon; Lee, Haenghwa; Lee, Donghoon; Choi, Seungyeon; Shin, Jungwook; Jang, Woojin; Seo, Chang-Woo; Kim, Hee-Joung

    2017-03-01

    A compressed-sensing (CS) technique has been rapidly applied in medical imaging field for retrieving volumetric data from highly under-sampled projections. Among many variant forms, CS technique based on a total-variation (TV) regularization strategy shows fairly reasonable results in cone-beam geometry. In this study, we implemented the TV-based CS image reconstruction strategy in our prototype chest digital tomosynthesis (CDT) R/F system. Due to the iterative nature of time consuming processes in solving a cost function, we took advantage of parallel computing using graphics processing units (GPU) by the compute unified device architecture (CUDA) programming to accelerate our algorithm. In order to compare the algorithmic performance of our proposed CS algorithm, conventional filtered back-projection (FBP) and simultaneous algebraic reconstruction technique (SART) reconstruction schemes were also studied. The results indicated that the CS produced better contrast-to-noise ratios (CNRs) in the physical phantom images (Teflon region-of-interest) by factors of 3.91 and 1.93 than FBP and SART images, respectively. The resulted human chest phantom images including lung nodules with different diameters also showed better visual appearance in the CS images. Our proposed GPU-accelerated CS reconstruction scheme could produce volumetric data up to 80 times than CPU programming. Total elapsed time for producing 50 coronal planes with 1024×1024 image matrix using 41 projection views were 216.74 seconds for proposed CS algorithms on our GPU programming, which could match the clinically feasible time ( 3 min). Consequently, our results demonstrated that the proposed CS method showed a potential of additional dose reduction in digital tomosynthesis with reasonable image quality in a fast time.

  18. Effects of compression injury on brain mitochondrial and tissue viability evaluated by a multiparametric monitoring system

    NASA Astrophysics Data System (ADS)

    Barbiro-Michaely, Efrat; Bachbut, Galit; Mayevsky, Avraham

    2008-02-01

    Neurosurgical procedures involve brain compression created by retractors. Although it is clear that retractors are causing damage to the brain tissue, the pathophysiology of the retraction was not investigated in details. In the present study we used the multiparametric monitoring approach for real time evaluation of mitochondrial function, hemodynamic, ionic and electrical activities monitored contralaterally to the retractor placement on the brain. The aims of the study were to test the effects of retractor size and severity of the compression on the degree of damage to the cerebral tissue. A special probe was lowered towards the cerebral cortex, (2mm and 4mm in depth) using a micromanipulator. Compression lasted for 30 minutes, than the retractor was elevated back to its initial position and monitoring continued for two hours. Additionally, two sizes of retractors were used 6mm and 3mm in diameter, the 3mm retractor included an intracranial pressure (ICP) probe. The results show that the combination of a large retractor with the depth of 4mm yielded high mortality rate (62%) of the rats while the use of a smaller retractor decreased significantly the percentage of mortality. Also, compression to the depth of 4mm increased tissue injury as compared to 2mm depth. In conclusion, the present study raises the importance and significance of multiparametric monitoring, and not only ICP and cerebral blood flow of the areas nearby the retractor position and not only the retraction site, as well as the effect of the retractor size on the damage induced to the cerebral tissue.

  19. Toward the modeling of mucus draining from human lung: role of airways deformation on air-mucus interaction

    PubMed Central

    Mauroy, Benjamin; Flaud, Patrice; Pelca, Dominique; Fausser, Christian; Merckx, Jacques; Mitchell, Barrett R.

    2015-01-01

    Chest physiotherapy is an empirical technique used to help secretions to get out of the lung whenever stagnation occurs. Although commonly used, little is known about the inner mechanisms of chest physiotherapy and controversies about its use are coming out regularly. Thus, a scientific validation of chest physiotherapy is needed to evaluate its effects on secretions. We setup a quasi-static numerical model of chest physiotherapy based on thorax and lung physiology and on their respective biophysics. We modeled the lung with an idealized deformable symmetric bifurcating tree. Bronchi and their inner fluids mechanics are assumed axisymmetric. Static data from the literature is used to build a model for the lung's mechanics. Secretions motion is the consequence of the shear constraints apply by the air flow. The input of the model is the pressure on the chest wall at each time, and the output is the bronchi geometry and air and secretions properties. In the limit of our model, we mimicked manual and mechanical chest physiotherapy techniques. We show that for secretions to move, air flow has to be high enough to overcome secretion resistance to motion. Moreover, the higher the pressure or the quicker it is applied, the higher is the air flow and thus the mobilization of secretions. However, pressures too high are efficient up to a point where airways compressions prevents air flow to increase any further. Generally, the first effects of manipulations is a decrease of the airway tree hydrodynamic resistance, thus improving ventilation even if secretions do not get out of the lungs. Also, some secretions might be pushed deeper into the lungs; this effect is stronger for high pressures and for mechanical chest physiotherapy. Finally, we propose and tested two a dimensional numbers that depend on lung properties and that allow to measure the efficiency and comfort of a manipulation. PMID:26300780

  20. Impact of an open-chest extracorporeal membrane oxygenation model for in situ simulated team training: a pilot study.

    PubMed

    Atamanyuk, Iryna; Ghez, Olivier; Saeed, Imran; Lane, Mary; Hall, Judith; Jackson, Tim; Desai, Ajay; Burmester, Margarita

    2014-01-01

    To develop an affordable realistic open-chest extracorporeal membrane oxygenation (ECMO) model for embedded in situ interprofessional crisis resource management training in emergency management of a post-cardiac surgery child. An innovative attachment to a high-fidelity mannequin (Laerdal Simbaby) was used to enable a cardiac tamponade/ECMO standstill scenario. Two saline bags with blood dye were placed over the mannequin's chest. A 'heart' bag with venous and arterial outlets was connected to the corresponding tubes of the ECMO circuit. The bag was divided into arterial and venous parts by loosely wrapping silicon tubing around its centre. A 'pericardial' bag was placed above it. Both were then covered by a chest skin that had a sutured silicone membrane window. False blood injected into the 'pericardial' bag caused expansion leading to (i) bulging of silastic membrane, simulating tamponade, and (ii) compression of tubing around the 'heart' bag, creating negative venous pressures and cessation of ECMO flow. In situ Simulation Paediatric Resuscitation Team Training (SPRinT) was performed on paediatric intensive care unit; the course included a formal team training/scenario of an open-chest ECMO child with acute cardiac tamponade due to blocked chest drains/debriefing by trained facilitators. Cardiac tamponade was reproducible, and ECMO flow/circuit pressure changes were effective and appropriate. There were eight participants: one cardiac surgeon, two intensivists, one cardiologist, one perfusionist and three nurses. Five of the eight reported the realism of the model and 6/8 the realism of the clinical scenario as highly effective. Eight of eight reported a highly effective impact on (i) their practice and (ii) teamwork. Six of eight reported a highly effective impact on communication skills and increased confidence in attending future real events. Innovative adaptation of a high-fidelity mannequin for open-chest ECMO simulation can achieve a realistic and reproducible training model. The impact on interprofessional team training is promising but needs to be validated further.

  1. Clinical experience with orthotic repair of pectus carinatum.

    PubMed

    Al-Githmi, Iskander S

    2016-01-01

    Pectus carinatum is a congenital chest wall deformity characterized by protrusion of the sternum and adjacent costal cartilages. Multiple treatment options are available for correction of pectus carinatum. We report our initial experience with first-line treatment using a custom fitted dynamic compression orthosis. Prospective evaluation of all patients seen between November 2013 and December 2014. University hospital. The treatment protocol for patients who had pressure for initial correction.

  2. A new method to detect cerebral blood flow waveform in synchrony with chest compression by near-infrared spectroscopy during CPR.

    PubMed

    Koyama, Yasuaki; Wada, Takafumi; Lohman, Brandon D; Takamatsu, Yuka; Matsumoto, Junichi; Fujitani, Shigeki; Taira, Yasuhiko

    2013-10-01

    The objective of the study is to demonstrate the utility of near-infrared spectroscopy (NIRS) in evaluating chest compression (CC) quality in cardiac arrest (CA) patients as well as determine its prognosis predictive value. We present a nonconsecutive case series of adult patients with CA whose cardiopulmonary resuscitation (CPR) was monitored with NIRS and collected the total hemoglobin concentration change (ΔcHb), the tissue oxygen index (TOI), and the ΔTOI to assess CC quality in a noninvasive fashion. During CPR, ΔcHb displayed waveforms monitor, which we regarded as a surrogate for CC quality. Total hemoglobin concentration change waveforms responded accurately to variations or cessations of CCs. In addition, a TOI greater than 40% measured upon admission appears to be significant in predicting patient's outcome. Of 15 patients, 6 had a TOI greater than 40% measured upon admission, and 67% of the latter were in return of spontaneous circulation after CPR and were found to be significantly different between return of spontaneous circulation and death (P = .047; P < .05). Near-infrared spectroscopy reliably assesses the quality of CCs in patients with CA demonstrated by synchronous waveforms during CPR and possible prognostic predictive value, although further investigation is warranted. © 2013 Elsevier Inc. All rights reserved.

  3. [Effectiveness of resuscitation delivered by Polish paramedics].

    PubMed

    Guła, Przemysław; Koszowska, Małgorzata; Larysz, Dawid; Koszowski, Marcin; Nabzdyk, Andrzej; Maślanka, Marek

    2008-01-01

    The aim of the study was to evaluate the effectiveness and skills in BLS and use of automatic external defibrillators (AED) by paramedics from units of the National Fire and Rescue System. One hundred and fifty-eight rescuers participated in the study. They included both volunteers and professionals, and were recruited from 40 different rescue organizations. The results were evaluated by experienced physicians, nurses and paramedics, all holders of ALS and BLS-AED instructor diplomas. The following skills were evaluated: initial assessment, ventilation, chest compression, and use of the AED. The quality of the BLS-AED was rated against the professional experience of the rescuers, and the frequency of repetition training. Although theoretical background was rated good, 45% of participants omitted assessment of consciousness. Airway patency and respiration were properly assessed by 82.5% and 72.5% of paramedics respectively, but only 20% could provide adequate rescue breaths to the phantom victims. Circulation was correctly assessed by 65% of participants, but once again, only 34.4% of paramedics could provide adequate chest compression. The results correlated positively with professional experience, based on the number of rescue missions (0-250, mean 4.3, median 1). The results proved that despite adequate theoretical knowledge, practical skills of paramedics were poor, due to the inadequate time devoted to practical training and the lack of certificate courses.

  4. [Current international recommendations for pediatric cardiopulmonary resuscitation: the European guidelines].

    PubMed

    López-Herce, Jesús; Rodríguez Núñez, Antonio; Maconochie, Ian; Van de Voorde, Patric; Biarent, Dominique; Eich, Christof; Bingham, Robert; Rajka, Thomas; Zideman, David; Carrillo, Ángel; de Lucas, Nieves; Calvo, Custodio; Manrique, Ignacio

    2017-07-01

    This summary of the European guidelines for pediatric cardiopulmonary resuscitation (CPR) emphasizes the main changes and encourages health care professionals to keep their pediatric CPR knowledge and skills up to date. Basic and advanced pediatric CPR follow the same algorithm in the 2015 guidelines. The main changes affect the prevention of cardiac arrest and the use of fluids. Fluid expansion should not be used routinely in children with fever in the abuse of signs of shock because too high a volume can worsen prognosis. Rescue breaths should last around 1 second in basic CPR, making pediatric recommendations consistent with those for adults. Chest compressions should be at least as deep as one-third the anteroposterior diameter of the thorax. Most children in cardiac arrest lack a shockable rhythm, and in such cases a coordinated sequence of breaths, chest compressions, and administration of adrenalin is essential. An intraosseous canula may be the first choice for introducing fluids and medications, especially in young infants. In treating supraventricular tachycardia with cardioversion, an initial dose of 1 J/kg is currently recommended (vs the dose of 0.5 J/kg previously recommended). After spontaneous circulation is recovered, measures to control fever should be taken. The goal is to reach a normal temperature even before arrival to the hospital.

  5. Tension pneumothorax secondary to automatic mechanical compression decompression device.

    PubMed

    Hutchings, A C; Darcy, K J; Cumberbatch, G L A

    2009-02-01

    The details are presented of the first published case of a tension pneumothorax induced by an automatic compression-decompression (ACD) device during cardiac arrest. An elderly patient collapsed with back pain and, on arrival of the crew, was in pulseless electrical activity (PEA) arrest. He was promptly intubated and correct placement of the endotracheal tube was confirmed by noting equal air entry bilaterally and the ACD device applied. On the way to the hospital he was noted to have absent breath sounds on the left without any change in the position of the endotracheal tube. Needle decompression of the left chest caused a hiss of air but the patient remained in PEA. Intercostal drain insertion in the emergency department released a large quantity of air from his left chest but without any change in his condition. Post-mortem examination revealed a ruptured abdominal aortic aneurysm as the cause of death. Multiple left rib fractures and a left lung laceration secondary to the use of the ACD device were also noted, although the pathologist felt that the tension pneumothorax had not contributed to the patient's death. It is recommended that a simple or tension pneumothorax should be considered when there is unilateral absence of breath sounds in addition to endobronchial intubation if an ACD device is being used.

  6. Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation

    PubMed Central

    Lee, Sanghyun; Kim, Wonhee; Kang, Hyunggoo; Oh, Jaehoon; Lim, Tae Ho; Lee, Yoonjae; Kim, Changsun; Cho, Jun Hwi

    2015-01-01

    Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P < 0.05), whereas there was no significant difference between the two video laryngoscopes (in 15° tilt, P = 1; in 30° tilt, P = 0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P < 0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate. PMID:26161426

  7. Prediction by computerised tomography of distance from skin to epidural space during thoracic epidural insertion.

    PubMed

    Carnie, J; Boden, J; Gao Smith, F

    2002-07-01

    In this single group observational study on 29 patients, we describe a technique that predicts the depth of the epidural space, calculated from the routine pre-operative chest computerised tomography (CT) scan using Pythagorean triangle trigonometry. We also compared the CT-derived depth of the epidural space with the actual depth of needle insertion. The CT-derived and the actual depths of the epidural space were highly correlated (r = 0.88, R2 = 0.78, p < 0.0001). The mean (95% CI) difference between CT-derived and actual depths was 0.26 (0.03-0.49) cm. Thus, the CT-derived depth tends to be greater than the actual depth by between 0.03 and 0.49 cm. There were no associations between either the CT-derived or the actual depth of the epidural space and age, weight, height or body mass index.

  8. Acute spinal cord compression: a rare complication of dual antiplatelet therapy.

    PubMed

    Iskandar, Muhammad Zaid; Chong, Victor; Hutcheon, Stuart

    2015-07-22

    A 73-year-old woman presented with acute shortness of breath and exacerbation of chronic back pain. She was diagnosed with pulmonary oedema and a non-ST-elevation myocardial infarction following chest X-ray, ECG and high sensitivity troponin levels. She subsequently underwent coronary angioplasty with deployment of drug-eluting stents to her circumflex and left anterior descending arteries and was started on aspirin and clopidogrel for her dual antiplatelet therapy. Unfortunately, following the procedure, she gradually lost power and sensation in both lower limbs. MRI of her spine confirmed an extradural haematoma causing thoracic cord compression. She was managed conservatively following discussions with neurosurgeons and developed further complications secondary to her immobility. 2015 BMJ Publishing Group Ltd.

  9. Transpulmonary pressures and lung mechanics with glossopharyngeal insufflation and exsufflation beyond normal lung volumes in competitive breath-hold divers.

    PubMed

    Loring, Stephen H; O'Donnell, Carl R; Butler, James P; Lindholm, Peter; Jacobson, Francine; Ferrigno, Massimo

    2007-03-01

    Throughout life, most mammals breathe between maximal and minimal lung volumes determined by respiratory mechanics and muscle strength. In contrast, competitive breath-hold divers exceed these limits when they employ glossopharyngeal insufflation (GI) before a dive to increase lung gas volume (providing additional oxygen and intrapulmonary gas to prevent dangerous chest compression at depths recently greater than 100 m) and glossopharyngeal exsufflation (GE) during descent to draw air from compressed lungs into the pharynx for middle ear pressure equalization. To explore the mechanical effects of these maneuvers on the respiratory system, we measured lung volumes by helium dilution with spirometry and computed tomography and estimated transpulmonary pressures using an esophageal balloon after GI and GE in four competitive breath-hold divers. Maximal lung volume was increased after GI by 0.13-2.84 liters, resulting in volumes 1.5-7.9 SD above predicted values. The amount of gas in the lungs after GI increased by 0.59-4.16 liters, largely due to elevated intrapulmonary pressures of 52-109 cmH(2)O. The transpulmonary pressures increased after GI to values ranging from 43 to 80 cmH(2)O, 1.6-2.9 times the expected values at total lung capacity. After GE, lung volumes were reduced by 0.09-0.44 liters, and the corresponding transpulmonary pressures decreased to -15 to -31 cmH(2)O, suggesting closure of intrapulmonary airways. We conclude that the lungs of some healthy individuals are able to withstand repeated inflation to transpulmonary pressures far greater than those to which they would normally be exposed.

  10. Skill acquisition and retention in automated external defibrillator (AED) use and CPR by lay responders: a prospective study.

    PubMed

    Woollard, Malcolm; Whitfeild, Richard; Smith, Anna; Colquhoun, Michael; Newcombe, Robert G; Vetteer, Norman; Chamberlain, Douglas

    2004-01-01

    This prospective study evaluated the acquisition and retention of skills in cardio-pulmonary resuscitation (CPR) and the use of the automated external defibrillator (AED) by lay volunteers involved in the Department of Health, England National Defibrillator Programme. One hundred and twelve trainees were tested immediately before and after and initial 4-h class; 76 were similarly reassessed at refresher training 6 months later. A standardised test scenario that required assessment of the casualty, CPR and the use of on AED was evaluated using recording manikin data and video recordings. Before training only 44% of subjects delivered a shock. Afterwards, all did so and the average delay to first shock was reduced by 57 s. All trainees placed the defibrillator electrodes in an "acceptable" position after training, but very few did so in the recommended "ideal" position. After refresher training 80% of subjects used the correct sequence for CPR and shock delivery, yet a third failed to perform adequate safety checks before all shocks. The trainees self-assessed AED competence score was 86 (scale 0-100) after the initial class and their confidence that they would act in a real emergency was rated at a similar level. Initial training improved performance of all CPR skills, although all except compression rate had deteriorated after 6 months. The proportion of subjects able to correctly perform most CPR skill was higher following refresher training that after the initial class. Although this course was judged to be effective in teaching delivery of counter-shocks, the need was identified for more emphasis on positioning of electrodes, pre-shock safety checks, airway opening, ventilation volume, checking for signs of a circulation, hand positioning, and depth and rate of chest compressions.

  11. Hydroxocobalamin and Epinephrine Both Improve Survival in a Swine Model of Cyanide-Induced Cardiac Arrest

    DTIC Science & Technology

    2012-10-01

    Neurologic effects were not measured in this preliminary study. Oxygen therapy has been used as a sole treatment for cyanide toxicity; however, both groups...standardized mechanical chest compressions and were randomly assigned to receive one of 3 intravenous bolus therapies : hydroxocobalamin, epinephrine, or...arterial pressure and pH, decreased blood lactate and cyanide levels, and decreased the use of rescue epinephrine therapy compared with that in the

  12. Compression-only CPR training in elementary schools and student attitude toward CPR.

    PubMed

    Kitamura, Tetsuhisa; Nishiyama, Chika; Murakami, Yukiko; Yonezawa, Takahiro; Nakai, Shohei; Hamanishi, Masayoshi; Marukawa, Seishiro; Sakamoto, Tetsuya; Iwami, Taku

    2016-08-01

    Little is known about the effectiveness of systematic cardiopulmonary resuscitation (CPR) training for elementary school children. We introduced systematic training of chest compression-only CPR and automated external defibrillator (AED) use to elementary school students aged 10-12 years at 17 schools. The questionnaire compared student attitudes towards CPR and their knowledge about it before and after CPR training. We also evaluated parent and teacher views about CPR training in school education. The primary outcome was positive attitude, defined as "yes" and "maybe yes" on a 5 point Likert-type scale of student attitudes towards CPR.1 RESULTS: A total of 2047 elementary school students received CPR training. Of them, 1899 (92.8%) responded to the questionnaire regarding their attitude towards CPR before and after the training. Before training, 50.2% answered "yes" and 30.3% answered "maybe yes", to the question: "If someone suddenly collapses in front of you, can you do something such as check response or call emergency?" After training, their answers changed to 75.6% and 18.3% for "yes" and "maybe yes", respectively. Many of the students (72.3%, 271/370) who did not have a positive attitude before CPR training had a positive attitude after the training (P < 0.001). Most students understood how to perform CPR (97.7%) and use an AED (98.5%). Parents (96.2%, 1173/1220) and teachers (98.3%, 56/57) answered that it was "good" and "maybe good" for children to receive the training at elementary schools. Systematic chest compression-only CPR training helped elementary school students to improve their attitude towards CPR. © 2015 Japan Pediatric Society.

  13. Strength and compressibility of returned lunar soil.

    NASA Technical Reports Server (NTRS)

    Carrier, W. D., III; Bromwell, L. G.; Martin, R. T.

    1972-01-01

    Two oedometer and three direct shear tests have been performed in vacuum on a 200 g sample of lunar soil from Apollo 12 (12001, 119). The compressibility data have been used to calculate bulk density and shear wave velocity versus depth on the lunar surface. The shear wave velocity was found to increase approximately with the one-fourth power of the depth, and the results suggest that the Apollo 14 Active Seismic Experiment may not have detected the Fra Mauro formation at a depth of 8.5 m, but only naturally consolidated lunar soil. The shear data indicate that the strength of the lunar soil sample is about 65% that of a ground basalt simulant at the same void ratio.

  14. Tectonic Implications of Intermediate-depth Earthquakes Beneath the Northeast Caribbean

    NASA Astrophysics Data System (ADS)

    Mejia, H.; Pulliam, J.; Huerfano, V.; Polanco Rivera, E.

    2016-12-01

    The Caribbean-North American plate boundary transitions from normal subduction beneath the Lesser Antilles to oblique subduction at Hispaniola before becoming exclusively transform at Cuba. In the Greater Antilles, large earthquakes occur all along the plate boundary at shallow depths but intermediate-depth earthquakes (50-200 km focal depth) occur almost uniquely beneath eastern Hispaniola. Previous studies have suggested that regional tectonics may be dominated by, for example, opposing subducting slabs, tearing of the subducting North American slab, or "slab push" by the NA slab. In addition, the Bahamas Platform, located north of Hispaniola, is likely causing compressive stresses and clockwise rotation of the island. A careful examination of focal mechanisms of intermediate-depth earthquakes could clarify regional tectonics but seismic stations in the region have historically been sparse, so constraints on earthquake depths and focal mechanisms have been poor. In response, fifteen broadband sensors were deployed in the Dominican Republic in 2014, increasing the number of stations to twenty-two. To determine the roles earthquakes play in regional tectonics, a event catalog was created joining data from our stations and other regional stations for which event depths are greater than 50 km and magnitudes are greater than 3.5. All events have been relocated and focal mechanisms are presented for as many events as possible. Multiple probable fault planes are computed for each event. Compressive (P) and tensional (T) axes, from fault planes, are plotted in 3-dimensions with density distribution contours determined of each axis. Examining relationships between axes distributions and events helps constrain tectonic stresses at intermediate-depths beneath eastern Hispaniola. A majority of events show primary compressive axes oriented in a north-south direction, likely produced by collision with the Bahamas Platform.

  15. High-resolution three-dimensional imaging with compress sensing

    NASA Astrophysics Data System (ADS)

    Wang, Jingyi; Ke, Jun

    2016-10-01

    LIDAR three-dimensional imaging technology have been used in many fields, such as military detection. However, LIDAR require extremely fast data acquisition speed. This makes the manufacture of detector array for LIDAR system is very difficult. To solve this problem, we consider using compress sensing which can greatly decrease the data acquisition and relax the requirement of a detection device. To use the compressive sensing idea, a spatial light modulator will be used to modulate the pulsed light source. Then a photodetector is used to receive the reflected light. A convex optimization problem is solved to reconstruct the 2D depth map of the object. To improve the resolution in transversal direction, we use multiframe image restoration technology. For each 2D piecewise-planar scene, we move the SLM half-pixel each time. Then the position where the modulated light illuminates will changed accordingly. We repeat moving the SLM to four different directions. Then we can get four low-resolution depth maps with different details of the same plane scene. If we use all of the measurements obtained by the subpixel movements, we can reconstruct a high-resolution depth map of the sense. A linear minimum-mean-square error algorithm is used for the reconstruction. By combining compress sensing and multiframe image restoration technology, we reduce the burden on data analyze and improve the efficiency of detection. More importantly, we obtain high-resolution depth maps of a 3D scene.

  16. Automated Data Abstraction of Cardiopulmonary Resuscitation Process Measures for Complete Episodes of Cardiac Arrest Resuscitation.

    PubMed

    Lin, Steve; Turgulov, Anuar; Taher, Ahmed; Buick, Jason E; Byers, Adam; Drennan, Ian R; Hu, Samantha; J Morrison, Laurie

    2016-10-01

    Cardiopulmonary resuscitation (CPR) process measures research and quality assurance has traditionally been limited to the first 5 minutes of resuscitation due to significant costs in time, resources, and personnel from manual data abstraction. CPR performance may change over time during prolonged resuscitations, which represents a significant knowledge gap. Moreover, currently available commercial software output of CPR process measures are difficult to analyze. The objective was to develop and validate a software program to help automate the abstraction and transfer of CPR process measures data from electronic defibrillators for complete episodes of cardiac arrest resuscitation. We developed a software program to facilitate and help automate CPR data abstraction and transfer from electronic defibrillators for entire resuscitation episodes. Using an intermediary Extensible Markup Language export file, the automated software transfers CPR process measures data (electrocardiogram [ECG] number, CPR start time, number of ventilations, number of chest compressions, compression rate per minute, compression depth per minute, compression fraction, and end-tidal CO 2 per minute). We performed an internal validation of the software program on 50 randomly selected cardiac arrest cases with resuscitation durations between 15 and 60 minutes. CPR process measures were manually abstracted and transferred independently by two trained data abstractors and by the automated software program, followed by manual interpretation of raw ECG tracings, treatment interventions, and patient events. Error rates and the time needed for data abstraction, transfer, and interpretation were measured for both manual and automated methods, compared to an additional independent reviewer. A total of 9,826 data points were each abstracted by the two abstractors and by the software program. Manual data abstraction resulted in a total of six errors (0.06%) compared to zero errors by the software program. The mean ± SD time measured per case for manual data abstraction was 20.3 ± 2.7 minutes compared to 5.3 ± 1.4 minutes using the software program (p = 0.003). We developed and validated an automated software program that efficiently abstracts and transfers CPR process measures data from electronic defibrillators for complete cardiac arrest episodes. This software will enable future cardiac arrest studies and quality assurance programs to evaluate the impact of CPR process measures during prolonged resuscitations. © 2016 by the Society for Academic Emergency Medicine.

  17. Cardiovascular causes of airway compression.

    PubMed

    Kussman, Barry D; Geva, Tal; McGowan, Francis X

    2004-01-01

    Compression of the paediatric airway is a relatively common and often unrecognized complication of congenital cardiac and aortic arch anomalies. Airway obstruction may be the result of an anomalous relationship between the tracheobronchial tree and vascular structures (producing a vascular ring) or the result of extrinsic compression caused by dilated pulmonary arteries, left atrial enlargement, massive cardiomegaly, or intraluminal bronchial obstruction. A high index of suspicion of mechanical airway compression should be maintained in infants and children with recurrent respiratory difficulties, stridor, wheezing, dysphagia, or apnoea unexplained by other causes. Prompt diagnosis is required to avoid death and minimize airway damage. In addition to plain chest radiography and echocardiography, diagnostic investigations may consist of barium oesophagography, magnetic resonance imaging (MRI), computed tomography, cardiac catheterization and bronchoscopy. The most important recent advance is MRI, which can produce high quality three-dimensional reconstruction of all anatomic elements allowing for precise anatomic delineation and improved surgical planning. Anaesthetic technique will depend on the type of vascular ring and the presence of any congenital heart disease or intrinsic lesions of the tracheobronchial tree. Vascular rings may be repaired through a conventional posterolateral thoracotomy, or utilizing video-assisted thoracoscopic surgery (VATS) or robotic endoscopic surgery. Persistent airway obstruction following surgical repair may be due to residual compression, secondary airway wall instability (malacia), or intrinsic lesions of the airway. Simultaneous repair of cardiac defects and vascular tracheobronchial compression carries a higher risk of morbidity and mortality.

  18. Elastic flexure controls magma trajectories and explains the offset of primary volcanic activity upstream of mantle plume axis at la Réunion and Hawaii hotspot islands

    NASA Astrophysics Data System (ADS)

    Gerbault, Muriel; Fontaine, Fabrice J.; Rabinowicz, Michel; Bystricky, Misha

    2017-03-01

    Surface volcanism at la Réunion and Hawaii occurs with an offset of 150-180 km upstream to the plume axis with respect to the plate motion. This striking observation raises questions about the forcing of plume-lithosphere thermo-mechanical interactions on melt trajectories beneath these islands. Based on visco-elasto-plastic numerical models handled at kilometric resolution, we propose to explain this offset by the development of compressional stresses at the base of the lithosphere, that result from elastic plate bending above the upward load exerted by the plume head. This horizontal compression adopts a disc shape centered around the plume axis: (i) it is 20 km thick, (ii) it has a 150 km radius, (iii) it lays at the base of the elastic part of the lithosphere, i.e., around ∼50-70 km depth where the temperature varies from ∼600 °C to ∼750 °C, (iv) it lasts for 5 to 10 My in an oceanic plate of age greater than 70 My, and (vi) it is controlled by the visco-elastic relaxation time at ∼50-70 km depth. This period of time exceeds the time during which both the Somalian/East-African and Pacific plates drift over the Reunion and Hawaii plumes, respectively. This indicates that this basal compression is actually a persistent feature. It is inferred that the buoyant melts percolating in the plume head pond below this zone of compression and eventually spread laterally until the most compressive principal elastic stresses reverse to the vertical, i.e., ∼150 km away from the plume head. There, melts propagate through dikes upwards to ∼35 km depth, where the plate curvature reverses and ambient compression diminishes. This 30-35 km depth may thus host a magmatic reservoir where melts transported by dykes pond. Only after further magmatic differentiation can dykes resume their ascension up to the surface and begin forming a volcanic edifice. As the volcano grows because of melt accumulation at the top of the plate, the lithosphere is flexed downwards, inducing extra tensile stress at 30-35 km depth and compression at ∼15 km depth (induced by the edifice load). It implies that now the melts pond at ∼15 km and form another magmatic reservoir lying just underneath the crust. These processes explain the ponding of primary (shield) melts at ∼35 km and ∼15 km depths as recorded below La Reunion, Mauritius or Hawaii volcanoes, all shifted by ∼150 km with respect to the plume axis.

  19. Use of incentive spirometry in portable chest radiography.

    PubMed

    McEntee, Mark F; Houssein, Nariman; Al-azawi, Dhafir

    2014-01-01

    The degree of lung inflation seen on a chest radiograph is dependent on the point during the patient's respiratory cycle at which the radiographer exposes the image receptor. Exposing the image receptor at the exact peak of inflation can be difficult because of the limited time available in which to capture the inspiratory pause. An incentive spirometer can indicate the moment of peak inhalation. This study tested whether images taken with and without an incentive spirometer display different levels of image quality. This is a paired, prospective, single-blinded study of 30 patients undergoing portable chest radiography. The radiographs were acquired with and without the use of an incentive spirometer. Visual grading analysis was performed using the 1996 European Guidelines on Quality Criteria for Diagnostic Radiographic Images. The mean patient age was 53 years. Sixty images were acquired, 30 with the use of incentive spirometry and 30 without. The most common indication for portable chest radiography was "postlung lobectomy." Scoring on the radiologist's ability to see the sixth rib, spine, trachea, and cardiac border was not affected significantly by the use of incentive spirometry. Use of an incentive spirometer was associated with significant improvement in ability to see the 10th rib (P ≤ .004), vascular pattern (P ≤ .001), retrocardiac lung (P ≤ .013), and the costophrenic angles (P ≤ .005). This study introduces a technique to improve the quality of portable chest radiographs. The use of incentive spirometry improved inspiratory depth and image quality for portable chest radiographs.

  20. Brace compression for treatment of pectus carinatum.

    PubMed

    Jung, Joonho; Chung, Sang Ho; Cho, Jin Kyoung; Park, Soo-Jin; Choi, Ho; Lee, Sungsoo

    2012-12-01

    Surgery has been the classical treatment of pectus carinatum (PC), though compressive orthotic braces have shown successful results in recent years. We propose a non-operative approach using a lightweight, patient-controlled dynamic chest-bracing device. Eighteen patients with PC were treated between July 2008 and June 2009. The treatment involved fitting of the brace, which was worn for at least 20 hours per day for 6 months. Their degree of satisfaction (1, no correction; 4, remarkable correction) was measured at 12 months after the initiation of the treatment. Thirteen (72.2%) patients completed the treatment (mean time, 4.9±1.4 months). In patients who completed the treatment, the mean overall satisfaction score was 3.73±0.39. The mean satisfaction score was 4, and there was no recurrence of pectus carinatum in patients who underwent the treatment for at least 6 months. Minimal recurrence of pectus carinatum after removal of the compressive brace occurred in 5 (38.5%) patients who stopped wearing the compressive brace at 4 months. Compressive bracing results in a significant improvement in PC appearance in patients with an immature skeleton. However, patient compliance and diligent follow-up appear to be paramount for the success of this method of treatment. We currently offer this approach as a first-line treatment for PC.

  1. Minimal invasive treatment of life-threatening bleeding caused by cardiopulmonary resuscitation-associated liver injury: a case report.

    PubMed

    Næss, Pål Aksel; Engeseth, Kristian; Grøtta, Ole; Andersen, Geir Øystein; Gaarder, Christine

    2016-05-29

    Life-threatening bleeding caused by liver injury due to chest compressions is a rare complication in otherwise successful cardiopulmonary resuscitation. Surgical intervention has been suggested to achieve bleeding control; however, reported mortality is high. In this report, we present a brief literature review and a case report in which use of a less invasive strategy was followed by an uneventful recovery. A 37-year-old white woman was admitted after out-of-hospital cardiac arrest. Bystander cardiopulmonary resuscitation was immediately performed, followed by advanced cardiopulmonary resuscitation that included tracheal intubation, mechanical chest compressions, and external defibrillation with return of spontaneous circulation. Upon hospital admission, the patient's blood pressure was 94/45 mmHg and her heart rate was 110 beats per minute. Her electrocardiogram showed no signs of ST-segment elevations or Q-wave development. Coronary angiography revealed a proximal thrombotic occlusion of the left anterior descending coronary artery. Successful recanalization, after thrombus aspiration and balloon dilation followed by stent implant, was verified with normalized anterograde flow. Immediately after the patient's arrival in the intensive cardiac care unit, a drop in her blood pressure to 60/30 mmHg and a hemoglobin concentration of 4.5 g/dl were noticed. Transfusion was started, and bedside abdominal ultrasound examination revealed free intraperitoneal fluid. Computed tomography of the abdomen revealed liver injury with active extravasation from the cranial surface of the right lobe and a massive hemoperitoneum. The patient was coagulopathic and acidotic with a body temperature of 33.5 °C. A minimally invasive treatment strategy, including angiography and selective trans-catheter arterial embolization, were performed in combination with percutaneous evacuation of 4.5 L of intraperitoneal blood. After completion of these procedures, the patient was hemodynamically stable. She was weaned off mechanical ventilation 2 days later and made an uneventful recovery. She was discharged to a local hospital on day 13 without neurological disability. Although rare, bleeding caused by liver injury due to chest compressions can be life-threatening after successful cardiopulmonary resuscitation. Reported mortality is high after surgical intervention, and patients may benefit from less invasive treatment strategies such as those presented in this case report.

  2. Video-Only Cardiopulmonary Resuscitation Education for High-Risk Families Before Hospital Discharge: A Multicenter Pragmatic Trial.

    PubMed

    Blewer, Audrey L; Putt, Mary E; Becker, Lance B; Riegel, Barbara J; Li, Jiaqi; Leary, Marion; Shea, Judy A; Kirkpatrick, James N; Berg, Robert A; Nadkarni, Vinay M; Groeneveld, Peter W; Abella, Benjamin S

    2016-11-01

    Cardiopulmonary resuscitation (CPR) training rates in the United States are low, highlighting the need to develop CPR educational approaches that are simpler, with broader dissemination potential. The minimum training required to ensure long-term skill retention remains poorly characterized. We compared CPR skill retention among laypersons randomized to training with video-only (VO; no manikin) with those trained with a video self-instruction kit (VSI; with manikin). We hypothesized that VO training would be noninferior to the VSI approach with respect to chest compression (CC) rate. We performed a prospective, cluster randomized trial of CPR education for family members of patients with high-risk cardiac conditions on hospital cardiac units, using a multicenter pragmatic design. Eight hospitals were randomized to offer either VO or VSI training before discharge using volunteer trainers. CPR skills were assessed 6 months post training. Mean CC rate among those trained with VO compared with those trained with VSI was assessed with a noninferiority margin set at 8 CC per min; as a secondary outcome, mean differences in CC depth were assessed. From February 2012 to May 2015, 1464 subjects were enrolled and 522 subjects completed a skills assessment. The mean CC rates were 87.7 (VO) CC per min and 89.3 (VSI) CC per min; we concluded noninferiority for VO based on a mean difference of -1.6 (90% confidence interval, -5.2 to 2.1). The mean CC depth was 40.2 mm (VO) and 45.8 mm (VSI) with a mean difference of -5.6 (95% confidence interval, -7.6 to -3.7). Results were similar after multivariate regression adjustment. In this large, prospective trial of CPR skill retention, VO training yielded a noninferior difference in CC rate compared with VSI training. CC depth was greater in the VSI group. These findings suggest a potential trade-off in efforts for broad dissemination of basic CPR skills; VO training might allow for greater scalability and dissemination, but with a potential reduction in CC depth. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01514656. © 2016 American Heart Association, Inc.

  3. Video-Only Cardiopulmonary Resuscitation Education for High-Risk Families Before Hospital Discharge: A Multicenter Pragmatic Trial

    PubMed Central

    Blewer, Audrey L.; Putt, Mary E.; Becker, Lance B.; Riegel, Barbara J.; Li, Jiaqi; Leary, Marion; Shea, Judy A.; Kirkpatrick, James N.; Berg, Robert A.; Nadkarni, Vinay M.; Groeneveld, Peter W.; Abella, Benjamin S.

    2016-01-01

    Background CPR training rates in the US are low, highlighting the need to develop CPR educational approaches that are simpler, with broader dissemination potential. The minimum training required to ensure long-term skill retention remains poorly characterized. We compared CPR skill retention among laypersons randomized to training with video-only (VO; no manikin) to those trained with a video self-instruction kit (VSI; with manikin). We hypothesized that VO training would be non-inferior to the VSI approach with respect to chest compression (CC) rate. Methods and Results We performed a prospective cluster randomized trial of CPR education for family members of high-risk cardiac patients on hospital cardiac units, using a multicenter pragmatic design. Eight hospitals were randomized to offer either VO or VSI training before discharge using volunteer trainers. CPR skills were assessed six months post-training. Mean CC rate among those trained with VO compared to VSI was assessed with a non-inferiority margin set at 8 CC per min (cpm); as a secondary outcome, mean differences in CC depth were assessed. From 2/2012 to 5/2015, 1464 subjects were enrolled and 522 subjects completed a skills assessment. The mean CC rates were 87.7(VO) cpm and 89.3 (VSI) cpm; we concluded non-inferiority for VO based on a mean difference of −1.6 (90% CI: −5.2, 2.1). The mean CC depth was 40.2 mm (VO) and 45.8 mm (VSI) with a mean difference of −5.6 (95% CI: −7.6, −3.7). Results were similar after multivariate regression adjustment. Conclusions In this large prospective trial of CPR skill retention, VO training yielded a non-inferior difference in CC rate compared to VSI training. CC depth was greater in the VSI group. These findings suggest a potential trade-off in efforts for broad dissemination of basic CPR skills; VO training might allow for greater scalability and dissemination, but with a potential reduction in CC depth. Clinical Trial Registration URL: ClinicalTrials.gov, Identifier: NCT01514656. PMID:27703033

  4. Depth assisted compression of full parallax light fields

    NASA Astrophysics Data System (ADS)

    Graziosi, Danillo B.; Alpaslan, Zahir Y.; El-Ghoroury, Hussein S.

    2015-03-01

    Full parallax light field displays require high pixel density and huge amounts of data. Compression is a necessary tool used by 3D display systems to cope with the high bandwidth requirements. One of the formats adopted by MPEG for 3D video coding standards is the use of multiple views with associated depth maps. Depth maps enable the coding of a reduced number of views, and are used by compression and synthesis software to reconstruct the light field. However, most of the developed coding and synthesis tools target linearly arranged cameras with small baselines. Here we propose to use the 3D video coding format for full parallax light field coding. We introduce a view selection method inspired by plenoptic sampling followed by transform-based view coding and view synthesis prediction to code residual views. We determine the minimal requirements for view sub-sampling and present the rate-distortion performance of our proposal. We also compare our method with established video compression techniques, such as H.264/AVC, H.264/MVC, and the new 3D video coding algorithm, 3DV-ATM. Our results show that our method not only has an improved rate-distortion performance, it also preserves the structure of the perceived light fields better.

  5. Spool-like stent for the open sternum after cardiac operations.

    PubMed

    Satoh, H; Sakai, K; Koyama, M; Matsuda, H

    1997-02-01

    Severe edematous heart after a cardiac operation is impossible to treat if there is compression of the heart due to the sternum. In these patients delayed sternal closure may be a useful procedure until the heart decreases in size. We devised a spool-like stent for the open sternum to maintain the optimal cardiac space for the severely edematous heart and to fix the chest wall to allow for management while the sternum is open.

  6. Pre-recorded instructional audio vs. dispatchers' conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study.

    PubMed

    Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey

    2018-01-01

    To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio ( n =57); or (2) verbal dispatcher assistance ( n =52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P >0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P <0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min -1 ) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.

  7. Observer detection of image degradation caused by irreversible data compression processes

    NASA Astrophysics Data System (ADS)

    Chen, Ji; Flynn, Michael J.; Gross, Barry; Spizarny, David

    1991-05-01

    Irreversible data compression methods have been proposed to reduce the data storage and communication requirements of digital imaging systems. In general, the error produced by compression increases as an algorithm''s compression ratio is increased. We have studied the relationship between compression ratios and the detection of induced error using radiologic observers. The nature of the errors was characterized by calculating the power spectrum of the difference image. In contrast with studies designed to test whether detected errors alter diagnostic decisions, this study was designed to test whether observers could detect the induced error. A paired-film observer study was designed to test whether induced errors were detected. The study was conducted with chest radiographs selected and ranked for subtle evidence of interstitial disease, pulmonary nodules, or pneumothoraces. Images were digitized at 86 microns (4K X 5K) and 2K X 2K regions were extracted. A full-frame discrete cosine transform method was used to compress images at ratios varying between 6:1 and 60:1. The decompressed images were reprinted next to the original images in a randomized order with a laser film printer. The use of a film digitizer and a film printer which can reproduce all of the contrast and detail in the original radiograph makes the results of this study insensitive to instrument performance and primarily dependent on radiographic image quality. The results of this study define conditions for which errors associated with irreversible compression cannot be detected by radiologic observers. The results indicate that an observer can detect the errors introduced by this compression algorithm for compression ratios of 10:1 (1.2 bits/pixel) or higher.

  8. Pre-recorded instructional audio vs. dispatchers’ conversational assistance in telephone cardiopulmonary resuscitation: A randomized controlled simulation study

    PubMed Central

    Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey

    2018-01-01

    BACKGROUND: To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. METHODS: It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio (n=57); or (2) verbal dispatcher assistance (n=52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. RESULTS: There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P>0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P<0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min-1) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). CONCLUSION: When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.

  9. Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality.

    PubMed

    Broeders, Mireille J M; Ten Voorde, Marloes; Veldkamp, Wouter J H; van Engen, Ruben E; van Landsveld-Verhoeven, Cary; 't Jong-Gunneman, Machteld N L; de Win, Jos; Greve, Kitty Droogh-de; Paap, Ellen; den Heeten, Gerard J

    2015-03-01

    To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. There was no difference in pain experience between both paddles (mean difference NRS: 0.08 ± 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 ± 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC views.

  10. Usefulness of emergency ultrasound in nontraumatic cardiac arrest.

    PubMed

    Volpicelli, Giovanni

    2011-02-01

    Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. The Stop-Only-While-Shocking algorithm reduces hands-off time by 17% during cardiopulmonary resuscitation - a simulation study.

    PubMed

    Koch Hansen, Lars; Mohammed, Anna; Pedersen, Magnus; Folkestad, Lars; Brodersen, Jacob; Hey, Thomas; Lyhne Christensen, Nicolaj; Carter-Storch, Rasmus; Bendix, Kristoffer; Hansen, Morten R; Brabrand, Mikkel

    2016-12-01

    Reducing hands-off time during cardiopulmonary resuscitation (CPR) is believed to increase survival after cardiac arrests because of the sustaining of organ perfusion. The aim of our study was to investigate whether charging the defibrillator before rhythm analyses and shock delivery significantly reduced hands-off time compared with the European Resuscitation Council (ERC) 2010 CPR guideline algorithm in full-scale cardiac arrest scenarios. The study was designed as a full-scale cardiac arrest simulation study including administration of drugs. Participants were randomized into using the Stop-Only-While-Shocking (SOWS) algorithm or the ERC2010 algorithm. In SOWS, chest compressions were only interrupted for a post-charging rhythm analysis and immediate shock delivery. A Resusci Anne HLR-D manikin and a LIFEPACK 20 defibrillator were used. The manikin recorded time and chest compressions. Sample size was calculated with an α of 0.05 and 80% power showed that we should test four scenarios with each algorithm. Twenty-nine physicians participated in 11 scenarios. Hands-off time was significantly reduced 17% using the SOWS algorithm compared with ERC2010 [22.1% (SD 2.3) hands-off time vs. 26.6% (SD 4.8); P<0.05]. In full-scale cardiac arrest simulations, a minor change consisting of charging the defibrillator before rhythm check reduces hands-off time by 17% compared with ERC2010 guidelines.

  12. Parametric study on single shot peening by dimensional analysis method incorporated with finite element method

    NASA Astrophysics Data System (ADS)

    Wu, Xian-Qian; Wang, Xi; Wei, Yan-Peng; Song, Hong-Wei; Huang, Chen-Guang

    2012-06-01

    Shot peening is a widely used surface treatment method by generating compressive residual stress near the surface of metallic materials to increase fatigue life and resistance to corrosion fatigue, cracking, etc. Compressive residual stress and dent profile are important factors to evaluate the effectiveness of shot peening process. In this paper, the influence of dimensionless parameters on maximum compressive residual stress and maximum depth of the dent were investigated. Firstly, dimensionless relations of processing parameters that affect the maximum compressive residual stress and the maximum depth of the dent were deduced by dimensional analysis method. Secondly, the influence of each dimensionless parameter on dimensionless variables was investigated by the finite element method. Furthermore, related empirical formulas were given for each dimensionless parameter based on the simulation results. Finally, comparison was made and good agreement was found between the simulation results and the empirical formula, which shows that a useful approach is provided in this paper for analyzing the influence of each individual parameter.

  13. Practical use of bone scan in patients with an osteoporotic vertebral compression fracture.

    PubMed

    Jun, Deuk Soo; An, Byoung Keun; Yu, Chang Hun; Hwang, Kyung Hoon; Paik, Je Won

    2015-02-01

    Rib fractures are one of main causes of chest or flank pain when related to an osteoporotic vertebral compression fracture (OVCF). The authors investigated the incidence and risk factors of rib fracture in 284 patients with OVCF using bone scans and evaluated the feasibility as to whether bone scans could be utilized as a useful screening tool. Hot uptake lesions on ribs were found in 122 cases (43.0%). The factors analyzed were age, sex, number and locations of fractured vertebrae, BMD, and compression rates as determined using initial radiography. However, no statistical significances were found. In 16 cases (5.6%), there were concurrent multiple fractures of both the thoracic and lumbar spines not detected by single site MRI. Sixty cases (21.1%) of OVCF with the a compression rate of less than 15% could not be identified definitely by initial plain radiography, but were confirmed by bone scans. It is concluded that a bone scan has outstanding ability for the screening of rib fractures associated with OVCF. Non-adjacent multiple fractures in both thoracic and lumbar spines and fractures not identified definitely by plain radiography were detected on bone scans, which provided a means for determining management strategies and predicting prognosis.

  14. Monitoring of in-hospital cardiac arrest events with the focus on Automated External Defibrillators--a retrospective observational study.

    PubMed

    Wurmb, Thomas; Vollmer, Tina; Sefrin, Peter; Kraus, Martin; Happel, Oliver; Wunder, Christian; Steinisch, Andreas; Roewer, Norbert; Maier, Sebastian

    2015-10-31

    Patients with cardiac arrest have lower survival rates, when resuscitation performance is low. In In-hospital settings the first responders on scene are usually nursing staff without rhythm analysing skills. In such cases Automated External Defibrillators (AED) might help guiding resuscitation performance. At the Wuerzburg University Hospital (Germany) an AED-program was initiated in 2007. Aim of the presented study was to monitor the impact of Automated External Defibrillators on the management of in-hospital cardiac arrest events. The data acquisition was part of a continuous quality improvement process of the Wuerzburg University Hospital. For analysing the CPR performance, the chest compression rate (CCR), compression depth (CCD), the no flow fraction (NFF), time interval from AED-activation to the first compression (TtC), the time interval from AED-activation to the first shock (TtS) and the post schock pause (TtCS) were determined by AED captured data. A questionnaire was completed by the first responders. From 2010 to 2012 there were 359 emergency calls. From these 53 were cardiac arrests with an AED-application. Complete data were available in 46 cases. The TtC was 34 (32-52) seconds (median and IQR).The TtS was 30 (28-32) seconds (median and IQR). The TtCS was 4 (3-6) seconds (median and IQR). The CCD was 5.5 ± 1 cm while the CCR was 107 ± 11/min. The NFF was calculated as 41 %. ROSC was achieved in 21 patients (45 %), 8 patients (17 %) died on scene and 17 patients (37 %) were transferred under ongoing CPR to an Intensive Care Unit (ICU). The TtS and TtC indicate that there is an AED-user dependent time loss. These time intervals can be markedly reduced, when the user is trained to interrupt the AED's "chain of advices" by placing the electrode-paddles immediately on the patient's thorax. At this time the AED switches directly to the analysing mode. Intensive training and adaption of the training contents is needed to optimize the handling of the AED in order to maximize its advantages and to minimize its disadvantages.

  15. The large lungs of elite swimmers: an increased alveolar number?

    PubMed

    Armour, J; Donnelly, P M; Bye, P T

    1993-02-01

    In order to obtain further insight into the mechanisms relating to the large lung volumes of swimmers, tests of mechanical lung function, including lung distensibility (K) and elastic recoil, pulmonary diffusion capacity, and respiratory mouth pressures, together with anthropometric data (height, weight, body surface area, chest width, depth and surface area), were compared in eight elite male swimmers, eight elite male long distance athletes and eight control subjects. The differences in training profiles of each group were also examined. There was no significant difference in height between the subjects, but the swimmers were younger than both the runners and controls, and both the swimmers and controls were heavier than the runners. Of all the training variables, only the mean total distance in kilometers covered per week was significantly greater in the runners. Whether based on: (a) adolescent predicted values; or (b) adult male predicted values, swimmers had significantly increased total lung capacity ((a) 145 +/- 22%, (mean +/- SD) (b) 128 +/- 15%); vital capacity ((a) 146 +/- 24%, (b) 124 +/- 15%); and inspiratory capacity ((a) 155 +/- 33%, (b) 138 +/- 29%), but this was not found in the other two groups. Swimmers also had the largest chest surface area and chest width. Forced expiratory volume in one second (FEV1) was largest in the swimmers ((b) 122 +/- 17%) and FEV1 as a percentage of forced vital capacity (FEV1/FVC)% was similar for the three groups. Pulmonary diffusing capacity (DLCO) was also highest in the swimmers (117 +/- 18%). All of the other indices of lung function, including pulmonary distensibility (K), elastic recoil and diffusion coefficient (KCO), were similar. These findings suggest that swimmers may have achieved greater lung volumes than either runners or control subjects, not because of greater inspiratory muscle strength, or differences in height, fat free mass, alveolar distensibility, age at start of training or sternal length or chest depth, but by developing physically wider chests, containing an increased number of alveoli, rather than alveoli of increased size. However, in this cross-sectional study, hereditary factors cannot be ruled out, although we believe them to be less likely.

  16. Cardiopulmonary resuscitation using the cardio vent device in a resuscitation model.

    PubMed

    Suner, Selim; Jay, Gregory D; Kleinman, Gary J; Woolard, Robert H; Jagminas, Liudvikas; Becker, Bruce M

    2002-05-01

    To compare the "Bellows on Sternum Resuscitation" (BSR) device that permits simultaneous compression and ventilation by one rescuer with two person cardiopulmonary resuscitation (CPR) with bag-valve-mask (BVM) ventilation in a single blind crossover study performed in the laboratory setting. Tidal volume and compression depth were recorded continuously during 12-min CPR sessions with the BSR device and two person CPR. Six CPR instructors performed a total of 1,894 ventilations and 10,532 compressions in 3 separate 12-min sessions. Mean tidal volume (MTV) and compression rate (CR) with the BSR device differed significantly from CPR with the BVM group (1242 mL vs. 1065 mL, respectively, p = 0.0018 and 63.2 compressions per minute (cpm) vs. 81.3 cpm, respectively, p = 0.0076). Error in compression depth (ECD) rate of 9.78% was observed with the BSR device compared to 8.49% with BMV CPR (p = 0.1815). Error rate was significantly greater during the second half of CPR sessions for both BSR and BVM groups. It is concluded that one-person CPR with the BSR device is equivalent to two-person CPR with BVM in all measured parameters except for CR. Both groups exhibited greater error rate in CPR performance in the latter half of 12-min CPR sessions.

  17. Spatial Distribution of Amorphization Intensity in Boron Carbide During Rate-Dependent Indentation and Impact Processes

    NASA Astrophysics Data System (ADS)

    Parsard, Gregory G.

    Boron carbide is a lightweight ceramic commonly used in applications requiring high hardness. At sufficiently high stresses, the material experiences a localized phase transformation (amorphization) which seemingly weakens its structure. Raman spectroscopy is used to distinguish these transformed regions from crystalline material based on the evolution of new peaks in collected Raman spectra. Vickers indentations of various loads were created at quasistatic and dynamic strain rates to trigger amorphization. The resulting imprints and subsurface regions were scanned with Raman spectroscopy to map amorphization intensity at several depths to generate three-dimensional representations of the amorphized zones, which were analyzed to determine the influence of load and strain rate upon amorphized zone characteristics. The square of amorphized zone depth beneath Vickers indentations increases linearly with load and shows little to no strain rate dependence. Sudden decreases in amorphization intensity at certain depths coincided with the presence of lateral cracks, suggesting that lateral cracks may lead to a loss of amorphized material during mechanical polishing. Experimental results were compared against finite element simulations to estimate critical values of stress and strain associated with amorphization. Raman spectra were also analyzed to determine the indentation-induced residual compressive pressure in crystalline boron carbide. In unstressed crystalline boron carbide, a peak exists near 1088 cm-1 which shifts to higher wavenumbers with the application of compressive pressure. The change in position of this crystalline peak was tracked across surfaces at various depths beneath the indentations and then converted into pressure using the piezospectroscopic coefficient of boron carbide. Residual compressive pressures on the order of gigapascals were found near the indentations, with stress relaxation near regions affected by radial cracks, spall, and graphitic inclusions. These measured residual compressive pressures were consistently higher than those predicted by finite element simulations at various loads, suggesting that amorphization, which was not accounted for by the simulations, may increase compressive residual stress in the crystalline material. Amorphization may cause affected regions to expand relative to their formerly crystalline state and exerting radial compressive forces upon the surrounding crystalline regions and circumferential tension along its boundary, thus promoting crack propagation within the amorphized region.

  18. A new physiological model for studying the effect of chest compression and ventilation during cardiopulmonary resuscitation: The Thiel cadaver.

    PubMed

    Charbonney, Emmanuel; Delisle, Stéphane; Savary, Dominique; Bronchti, Gilles; Rigollot, Marceau; Drouet, Adrien; Badat, Bilal; Ouellet, Paul; Gosselin, Patrice; Mercat, Alain; Brochard, Laurent; Richard, Jean-Christophe M

    2018-04-01

    Studying ventilation and intrathoracic pressure (ITP) induced by chest compressions (CC) during Cardio Pulmonary Resuscitation is challenging and important aspects such as airway closure have been mostly ignored. We hypothesized that Thiel Embalmed Cadavers could constitute an appropriate model. We assessed respiratory mechanics and ITP during CC in 11 cadavers, and we compared it to measurements obtained in 9 out-of-hospital cardiac arrest patients and to predicted values from a bench model. An oesophageal catheter was inserted to assess chest wall compliance, and ITP variation (ΔITP). Airway pressure variation (ΔPaw) at airway opening and ΔITP generated by CC were measured at decremental positive end expiratory pressure (PEEP) to test its impact on flow and ΔPaw. The patient's data were derived from flow and airway pressure captured via the ventilator during resuscitation. Resistance and Compliance of the respiratory system were comparable to those of the out-of-hospital cardiac arrest patients (C RS TEC 42 ± 12 vs C RS PAT 37.3 ± 10.9 mL/cmH 2 O and Res TEC 17.5 ± 7.5 vs Res PAT 20.2 ± 5.3 cmH 2 O/L/sec), and remained stable over time. During CC, ΔITP varied from 32 ± 12 cmH 2 O to 69 ± 14 cmH 2 O with manual and automatic CC respectively. Transmission of ΔITP at the airway opening was significantly affected by PEEP, suggesting dynamic small airway closure at low lung volumes. This phenomenon was similarly observed in patients. Respiratory mechanics and dynamic pressures during CC of cadavers behave as predicted by a theoretical model and similarly to patients. The Thiel model is a suitable to assess ITP variations induced by ventilation during CC. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Human Physiology in an Aquatic Environment.

    PubMed

    Pendergast, David R; Moon, Richard E; Krasney, John J; Held, Heather E; Zamparo, Paola

    2015-09-20

    Water covers over 70% of the earth, has varying depths and temperatures and contains much of the earth's resources. Head-out water immersion (HOWI) or submersion at various depths (diving) in water of thermoneutral (TN) temperature elicits profound cardiorespiratory, endocrine, and renal responses. The translocation of blood into the thorax and elevation of plasma volume by autotransfusion of fluid from cells to the vascular compartment lead to increased cardiac stroke volume and output and there is a hyperperfusion of some tissues. Pulmonary artery and capillary hydrostatic pressures increase causing a decline in vital capacity with the potential for pulmonary edema. Atrial stretch and increased arterial pressure cause reflex autonomic responses which result in endocrine changes that return plasma volume and arterial pressure to preimmersion levels. Plasma volume is regulated via a reflex diuresis and natriuresis. Hydrostatic pressure also leads to elastic loading of the chest, increasing work of breathing, energy cost, and thus blood flow to respiratory muscles. Decreases in water temperature in HOWI do not affect the cardiac output compared to TN; however, they influence heart rate and the distribution of muscle and fat blood flow. The reduced muscle blood flow results in a reduced maximal oxygen consumption. The properties of water determine the mechanical load and the physiological responses during exercise in water (e.g. swimming and water based activities). Increased hydrostatic pressure caused by submersion does not affect stroke volume; however, progressive bradycardia decreases cardiac output. During submersion, compressed gas must be breathed which introduces the potential for oxygen toxicity, narcosis due to nitrogen, and tissue and vascular gas bubbles during decompression and after may cause pain in joints and the nervous system. Copyright © 2015 John Wiley & Sons, Inc.

  20. Monitoring of cerebral oxygen saturation during resuscitation in out-of-hospital cardiac arrest: a feasibility study in a physician staffed emergency medical system.

    PubMed

    Schewe, Jens-Christian; Thudium, Marcus O; Kappler, Jochen; Steinhagen, Folkert; Eichhorn, Lars; Erdfelder, Felix; Heister, Ulrich; Ellerkmann, Richard

    2014-10-05

    Despite recent advances in resuscitation algorithms, neurological injury after cardiac arrest due to cerebral ischemia and reperfusion is one of the reasons for poor neurological outcome. There is currently no adequate means of measuring cerebral perfusion during cardiac arrest. It was the aim of this study to investigate the feasibility of measuring near infrared spectroscopy (NIRS) as a potential surrogate parameter for cerebral perfusion in patients with out-of-hospital resuscitations in a physician-staffed emergency medical service. An emergency physician responding to out-of-hospital emergencies was equipped with a NONIN cerebral oximetry device. Cerebral oximetry values (rSO2) were continuously recorded during resuscitation and transport. Feasibility was defined as >80% of total achieved recording time in relation to intended recording time. 10 patients were prospectively enrolled. In 89.8% of total recording time, rSO2 values could be recorded (213 minutes and 20 seconds), thus meeting feasibility criteria. 3 patients experienced return of spontaneous circulation (ROSC). rSO2 during manual cardiopulmonary resuscitation (CPR) was lower in patients who did not experience ROSC compared to the 3 patients with ROSC (31.6%, ± 7.4 versus 37.2% ± 17.0). ROSC was associated with an increase in rSO2. Decrease of rSO2 indicated occurrence of re-arrest in 2 patients. In 2 patients a mechanical chest compression device was used. rSO2 values during mechanical compression were increased by 12.7% and 19.1% compared to manual compression. NIRS monitoring is feasible during resuscitation of patients with out-of-hospital cardiac arrest and can be a useful tool during resuscitation, leading to an earlier detection of ROSC and re-arrest. Higher initial rSO2 values during CPR seem to be associated with the occurrence of ROSC. The use of mechanical chest compression devices might result in higher rSO2. These findings need to be confirmed by larger studies.

  1. The right view from the wrong location: depth perception in stereoscopic multi-user virtual environments.

    PubMed

    Pollock, Brice; Burton, Melissa; Kelly, Jonathan W; Gilbert, Stephen; Winer, Eliot

    2012-04-01

    Stereoscopic depth cues improve depth perception and increase immersion within virtual environments (VEs). However, improper display of these cues can distort perceived distances and directions. Consider a multi-user VE, where all users view identical stereoscopic images regardless of physical location. In this scenario, cues are typically customized for one "leader" equipped with a head-tracking device. This user stands at the center of projection (CoP) and all other users ("followers") view the scene from other locations and receive improper depth cues. This paper examines perceived depth distortion when viewing stereoscopic VEs from follower perspectives and the impact of these distortions on collaborative spatial judgments. Pairs of participants made collaborative depth judgments of virtual shapes viewed from the CoP or after displacement forward or backward. Forward and backward displacement caused perceived depth compression and expansion, respectively, with greater compression than expansion. Furthermore, distortion was less than predicted by a ray-intersection model of stereo geometry. Collaboration times were significantly longer when participants stood at different locations compared to the same location, and increased with greater perceived depth discrepancy between the two viewing locations. These findings advance our understanding of spatial distortions in multi-user VEs, and suggest a strategy for reducing distortion.

  2. Feasibility of spatial frequency-domain imaging for monitoring palpable breast lesions

    NASA Astrophysics Data System (ADS)

    Robbins, Constance M.; Raghavan, Guruprasad; Antaki, James F.; Kainerstorfer, Jana M.

    2017-12-01

    In breast cancer diagnosis and therapy monitoring, there is a need for frequent, noninvasive disease progression evaluation. Breast tumors differ from healthy tissue in mechanical stiffness as well as optical properties, which allows optical methods to detect and monitor breast lesions noninvasively. Spatial frequency-domain imaging (SFDI) is a reflectance-based diffuse optical method that can yield two-dimensional images of absolute optical properties of tissue with an inexpensive and portable system, although depth penetration is limited. Since the absorption coefficient of breast tissue is relatively low and the tissue is quite flexible, there is an opportunity for compression of tissue to bring stiff, palpable breast lesions within the detection range of SFDI. Sixteen breast tissue-mimicking phantoms were fabricated containing stiffer, more highly absorbing tumor-mimicking inclusions of varying absorption contrast and depth. These phantoms were imaged with an SFDI system at five levels of compression. An increase in absorption contrast was observed with compression, and reliable detection of each inclusion was achieved when compression was sufficient to bring the inclusion center within ˜12 mm of the phantom surface. At highest compression level, contrasts achieved with this system were comparable to those measured with single source-detector near-infrared spectroscopy.

  3. Computational mineral physics and the physical properties of perovskite.

    PubMed

    Brodholt, John P; Oganov, A R; Price, G D

    2002-11-15

    The inherent uncertainties in modern first-principles calculations are reviewed using geophysically relevant examples. The elastic constants of perovskite at lower-mantle temperatures and pressures are calculated using ab initio molecular dynamics. These are used in conjunction with seismic tomographic models to estimate that the lateral temperature contrasts in the Earth's lower mantle are 800 K at a depth of 1000 km, and 1500 K at a depth of 2000 km. The effect of Al(3+) on the compressibility of MgSiO(3) perovskite is calculated using three different pseudopotentials. The results confirm earlier work and show that the compressibility of perovskites with Al(3+) substituted for both Si(4+) and Mg(2+) is very similar to the compressibility of Al(3+)-free perovskite. Even when 100% of the Si(4+) and Mg(2+) ions are replaced with Al(3+), the bulk modulus is only 7% less than that for Al(3+)-free perovskite. In contrast, perovskites where Al(3+) substitutes for Si(4+) only and that are charge balanced by oxygen vacancies do show higher compressibilities. When corrected to similar concentrations of Al(3+), the calculated compressibilities of the oxygen-vacancy-rich perovskites are in agreement with experimental results.

  4. Numerical analysis of laser-driven reservoir dynamics for shockless loading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Mu; Zhang Hongping; Sun Chengwei

    2011-05-01

    Laser-driven plasma loader for shockless compression provides a new approach to study the rapid compression response of materials not attainable in conventional shock experiments. In this method, the strain rate is varied from {approx}10{sup 6}/s to {approx}10{sup 8}/s, significantly higher than other shockless compression methods. Thus, this loading process is attractive in the research of solid material dynamics and astrophysics. The objective of the current study is to demonstrate the dynamic properties of the jet from the rear surface of the reservoir, and how important parameters such as peak load, rise time, shockless compression depth, and stagnating melt depth inmore » the sample vary with laser intensity, laser pulse length, reservoir thickness, vacuum gap size, and even the sample material. Numerical simulations based on the space-time conservation element and solution element method, together with the bulk ablation model, were used. The dynamics of the reservoir depend on the laser intensity, pulse length, equation of state, as well as the molecular structure of the reservoir. The critical pressure condition at which the reservoir will unload, similar to a gas or weak plasma, is 40-80 GPa before expansion. The momentum distribution bulges downward near the front of the plasma jet, which is an important characteristic that determines shockless compression. The total energy density is the most important parameter, and has great influence on the jet characteristics, and consequently on the shockless compression characteristics. If the reservoir is of a single material irradiated at a given laser condition, the relation of peak load and shockless compression depth is in conflict, and the highest loads correspond to the smallest thickness of sample. The temperature of jet front runs up several electron volts after impacting on the sample, and the heat transfer between the stagnating plasma and the sample is sufficiently significant to induce the melting of the sample surface. However, this diffusion heat wave propagates much more slowly than the stress wave, and has minimal effect on the shockless compression progress at a deeper position.« less

  5. Pulsed Dose Delivery of Oxygen in Mechanically Ventilated Pigs with Acute Lung Injury

    DTIC Science & Technology

    2013-03-01

    collapse or arrhythmia were encountered after administration of oleic acid, chest compressions, electrical defibrillation , and epinephrine (0.1-1 mg/kg...endotracheal tube to continuously measure the oxygen content of the gas in the circuit. We designed the study as a crossover trial, so each animal served as... designed to prove that a pulsed dose delivery system would be a better method of oxygen delivery, it is interesting to note that pulsed dose delivery did

  6. Assessment of the Accuracy of Certain Reduced Order Models used in the Prediction of Occupant Injury during Under-Body Blast Events

    DTIC Science & Technology

    2014-04-15

    the floor on which the platform is dropped upon. Alternatively, a base excitation can be provided to the sliding platform in the upward vertical...7ms clips of chest resultant acceleration, (7) 7ms clip of pelvic vertical acceleration, (8,9) Peak and 30ms clips of lumbar spine compression, and...10) Pelvic vertical Dynamic Response Index (DRI)[12]. The sample size for each of the three seating variants consisted of 230 MADYMO

  7. Congenital Symmastia: A 3-Step Approach

    PubMed Central

    Allam, Atef A.

    2016-01-01

    Summary: Congenital symmastia is a medial confluence of the breasts. It is a rare anomaly with few reports in the literature and no standard treatment. In this article, we present a case of congenital symmastia treated by 3 steps: liposuction, fixation of the skin to the chest wall in the area of the intermammary sulcus, and postoperative intermammary compression. A successful result was achieved with normal cleavage between the breasts. So, this is considered the ideal treatment for this condition. PMID:28293510

  8. Brace Compression for Treatment of Pectus Carinatum

    PubMed Central

    Jung, Joonho; Chung, Sang Ho; Cho, Jin Kyoung; Park, Soo-Jin; Choi, Ho

    2012-01-01

    Background Surgery has been the classical treatment of pectus carinatum (PC), though compressive orthotic braces have shown successful results in recent years. We propose a non-operative approach using a lightweight, patient-controlled dynamic chest-bracing device. Materials and Methods Eighteen patients with PC were treated between July 2008 and June 2009. The treatment involved fitting of the brace, which was worn for at least 20 hours per day for 6 months. Their degree of satisfaction (1, no correction; 4, remarkable correction) was measured at 12 months after the initiation of the treatment. Results Thirteen (72.2%) patients completed the treatment (mean time, 4.9±1.4 months). In patients who completed the treatment, the mean overall satisfaction score was 3.73±0.39. The mean satisfaction score was 4, and there was no recurrence of pectus carinatum in patients who underwent the treatment for at least 6 months. Minimal recurrence of pectus carinatum after removal of the compressive brace occurred in 5 (38.5%) patients who stopped wearing the compressive brace at 4 months. Conclusion Compressive bracing results in a significant improvement in PC appearance in patients with an immature skeleton. However, patient compliance and diligent follow-up appear to be paramount for the success of this method of treatment. We currently offer this approach as a first-line treatment for PC. PMID:23275922

  9. Ultrafast eclogite formation via melting-induced overpressure

    NASA Astrophysics Data System (ADS)

    Chu, Xu; Ague, Jay J.; Podladchikov, Yury Y.; Tian, Meng

    2017-12-01

    The conventional wisdom holds that metamorphic reactions take place at pressures near-lithostatic so that the thermodynamic pressure, reflected by the mineral assemblage, is directly correlated with depth. On the other hand, recent field-based observations and geodynamic simulations suggest that heterogeneous stress and significant pressure deviations above lithostatic (overpressure) can occur in Earth's crust. Here we show that eclogite, normally interpreted to form at great depths in subduction zones and Earth's mantle, may form at much shallower depths via local overpressure generated in crustal shear zones. The eclogites studied crop out as lenses hosted by felsic paragneiss in a sheared thrust slice and represent a local pressure and temperature anomaly in the Taconic orogenic belt, southern New England. Sharply-defined chemical zones in garnet, which record ∼5 kbar pressure rise and fall accompanied by a temperature increase of 150-200 °C, demonstrate extremely short timescales of diffusion. This requires anomalously fast compression (∼500 yrs) and decompression. We use coupled phase equilibria and garnet diffusion forward modeling to fit the observed garnet profiles and test the likely P- T- t paths using a Monte Carlo-type approach, accounting for off-center sectioning of garnet. The simulation shows that a ∼5 kbar pressure increase after the temperature peak is necessary to reproduce the garnet zoning. Remarkably, this post-peak-T compression (from 9 kbar to 14 kbar) lasted only ∼500 yrs. If the compression was due to burial along a lithostatic pressure gradient, the descent speed would exceed 30 m yr-1, defying any observed or modeled subduction rates. Local overpressure in response to partial melting in a confined volume (Vrijmoed et al., 2009) caused by transient shear heating can explain the ultra-fast compression without necessitating burial to great depth.

  10. Injury Patterns After the Landslide Disaster in Oshima, Tokyo, Japan on October 16, 2013.

    PubMed

    Homma, Yasuhiro; Watari, Taiji; Baba, Tomonori; Suzuki, Misako; Shimizu, Tadanori; Fujii, Yuji; Takazawa, Yuji; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-04-01

    Landslides represent a frequent and threatening natural disaster. The aim of this study was to investigate the injury patterns observed after a landslide and to discuss how to minimize the damage caused by a landslide disaster. A landslide occurred on Oshima Island, Japan, on October 16, 2013. A total of 49 victims with landslide-related injuries were identified and analyzed. The patients ranged in age from 5 to 89 years with an average age of 61.0±19.3 years. Of all patients, 69.4% were triaged as black. Of 15 patients who were treated in the nearest hospital (the only hospital on the island), 8 were triaged as red and yellow with severe chest or pelvic injury and a high Injury Severity Score (average score, 25.6; range, 4-45). Of these, 75% had chest injury and 75% had pelvic injury. The percentage of chest and/or pelvic injury was 100% in patients triaged as red or yellow. Traumatic asphyxia was diagnosed in 62.5% of these patients. Compression of the trunk was the main injury in patients triaged as red or yellow after this landslide disaster. Evacuation in advance, the rapid launch of emergency medical support, and knowledge of this specific injury pattern are essential to minimize the potential damage resulting from landslide disasters.

  11. A model of acoustic transmission in the respiratory system.

    PubMed

    Wodicka, G R; Stevens, K N; Golub, H L; Cravalho, E G; Shannon, D C

    1989-09-01

    A theoretical model of sound transmission from within the respiratory tract to the chest wall due to the motion of the walls of the large airways was developed. The vocal tract, trachea, and the first five bronchial generations are represented over the frequency range from 100 to 600 Hz by an equivalent acoustic circuit. This circuit allows the estimation of the magnitude of airway wall motion in response to an acoustic perturbation at the mouth. The radiation of sound through the surrounding lung parenchyma is represented as a cylindrical wave in a homogeneous mixture of air bubbles in water. The effect of thermal losses associated with the polytropic compressions and expansions of these bubbles by the acoustic wave is included and the chest wall is represented as a massive boundary to the wave propagation. The model estimates the magnitude of acceleration over the extrathoracic trachea and at three locations on the posterior chest wall in the same vertical plane. The predicted spectral characteristics of transmission are consistent with previous experimental observations. This theoretical approach suggests that the locations of the spectral peaks are a strong function of the geometry and the wall properties of the airways, while the attenuation at higher frequencies is primarily associated with the absorption of sound in the parenchyma.

  12. Return of spontaneous Circulation Is Not Affected by Different Chest Compression Rates Superimposed with Sustained Inflations during Cardiopulmonary Resuscitation in Newborn Piglets

    PubMed Central

    Li, Elliott S.; Cheung, Po-Yin; Lee, Tze-Fun; Lu, Min; O'Reilly, Megan

    2016-01-01

    Objective Recently, sustained inflations (SI) during chest compression (CC) have been suggested as an alternative to the current approach during neonatal resuscitation. However, the optimal rate of CC during SI has not yet been established. Our aim was to determine whether different CC rates during SI reduce time to return of spontaneous circulation (ROSC) and improve hemodynamic recovery in newborn piglets with asphyxia-induced bradycardia. Intervention and measurements Term newborn piglets were anesthetized, intubated, instrumented and exposed to 45-min normocapnic hypoxia followed by asphyxia. Resuscitation was initiated when heart rate decreased to 25% of baseline. Piglets were randomized into three groups: CC superimposed by SI at a rate of 90 CC per minute (SI+CC 90, n = 8), CC superimposed by SI at a rate of 120 CC per minute (SI+CC 120, n = 8), or a sham group (n = 6). Cardiac function, carotid blood flow, cerebral oxygenation and respiratory parameters were continuously recorded throughout the experiment. Main results Both treatment groups had similar time of ROSC, survival rates, hemodynamic and respiratory parameters during cardiopulmonary resuscitation. The hemodynamic recovery in the subsequent 4h was similar in both groups and was only slightly lower than sham-operated piglets at the end of experiment. Conclusion Newborn piglets resuscitated by SI+CC 120 did not show a significant advantage in ROSC, survival, and hemodynamic recovery as compared to those piglets resuscitated by SI+CC 90. PMID:27304210

  13. Simulated life-threatening emergency during robot-assisted surgery.

    PubMed

    Huser, Anna-Sophia; Müller, Dirk; Brunkhorst, Violeta; Kannisto, Päivi; Musch, Michael; Kröpfl, Darko; Groeben, Harald

    2014-06-01

    With the increasing use of robot-assisted techniques for urologic and gynecologic surgery in patients with severe comorbidities, the risk of a critical incidence during surgery increases. Due to limited access to the patient the start of effective measures to treat a life-threatening emergency could be delayed. Therefore, we tested the management of an acute emergency in an operating room setting with a full-size simulator in six complete teams. A full-size simulator (ISTAN, Meti, CA), modified to hold five trocars, was placed in a regular operating room and connected to a robotic system. Six teams (each with three nurses, one anesthesiologist, two urologists or gynecologists) were introduced to the scenario. Subsequently, myocardial fibrillation occurred. Time to first chest compression, removal of the robot, first defibrillation, and stabilization of circulation were obtained. After 7 weeks the simulation was repeated. The time to the start of chest compressions, removal of the robotic system, and first defibrillation were significantly improved at the second simulation. Time for restoration of stable circulation was improved from 417 ± 125 seconds to 224 ± 37 seconds (P=0.0054). Unexpected delays occurred during the first simulation because trocars had been removed from the patient but not from the robot, thus preventing the robot to be moved. Following proper training, resuscitation can be started within seconds. A repetition of the simulation significantly improved time for all steps of resuscitation. An emergency simulation of a multidisciplinary team in a real operating room setting can be strongly recommended.

  14. Dynamic Compression System: An Effective Nonoperative Treatment for Pectus Carinatum: A Single Center Experience in Basel, Switzerland.

    PubMed

    Sesia, Sergio B; Holland-Cunz, Stefan; Häcker, Frank-Martin

    2016-12-01

    Background  Several nonoperative treatments are currently available for the correction of pectus carinatum (PC). Objective  The objective of this study is to report our single center experience with the dynamic compression system (DCS). Materials and Methods  The DCS is a rigid aluminum brace. PC is reshaped into a normal appearance through anterior-posterior pressure and lateral expansion of the chest. Patients with chondrogladiolar PC were considered suitable for the nonoperative treatment with DCS. Results  In this study, 53 of 68 children (78%) with chondrogladiolar PC were assessed retrospectively: 2 children were corrected by surgery, 12/53 (23%) treated by a conventional orthesis, 11/53 (21%) remained without therapy because of minor PC, and 36/53 (68%) were treated using the DCS. Of these 36 patients, 17 (47%) are already cured with a good (7/17) to excellent (10/17) cosmetic result after a median treatment period of 9 months (range, 2.5-16 months). The mean daily time of wearing of the device for those 17 patients was 9 hours (range, 5-18). None abandoned the treatment and there were almost no complications. Conclusions  Lateral expansion of the chest and the possibility to measure the applied pressure seemed to be the key to DCSs success. We propose the DCS as first choice in the treatment of chondrogladiolar PC in children. Georg Thieme Verlag KG Stuttgart · New York.

  15. Hierarchy of stability factors in reverse shoulder arthroplasty.

    PubMed

    Gutiérrez, Sergio; Keller, Tony S; Levy, Jonathan C; Lee, William E; Luo, Zong-Ping

    2008-03-01

    Reverse shoulder arthroplasty is being used more frequently to treat irreparable rotator cuff tears in the presence of glenohumeral arthritis and instability. To date, however, design features and functions of reverse shoulder arthroplasty, which may be associated with subluxation and dislocation of these implants, have been poorly understood. We asked: (1) what is the hierarchy of importance of joint compressive force, prosthetic socket depth, and glenosphere size in relation to stability, and (2) is this hierarchy defined by underlying and theoretically predictable joint contact characteristics? We examined the intrinsic stability in terms of the force required to dislocate the humerosocket from the glenosphere of eight commercially available reverse shoulder arthroplasty devices. The hierarchy of factors was led by compressive force followed by socket depth; glenosphere size played a much lesser role in stability of the reverse shoulder arthroplasty device. Similar results were predicted by a mathematical model, suggesting the stability was determined primarily by compressive forces generated by muscles.

  16. Calculation of Seismic Waves from Explosions with Tectonic Stresses and Topography

    NASA Astrophysics Data System (ADS)

    Stevens, J. L.; O'Brien, M.

    2017-12-01

    We investigate the effects of explosion depth, tectonic stresses and topography on seismic waves from underground nuclear explosions. We perform three-dimensional nonlinear calculations of an explosion at several depths in the topography of the North Korean test site. We also perform a large number of two-dimensional axisymmetric calculations of explosions at depths from 150 to 1000 meters in four earth structures, with compressive and tensile tectonic stresses and with no tectonic stresses. We use the representation theorem to propagate the results of these calculations and calculate seismic waves at regional and teleseismic distances. We find that P-waves are not strongly affected by any of these effects because the initial downgoing P-wave is unaffected by interaction with the free surface. Surface waves, however, are strongly affected by all of these effects. There is an optimal depth at which surface waves are maximized at the base of a mountain and at or slightly below normal containment depth. At deeper depths, increasing overburden pressure reduces the surface waves. At shallower depths, interaction with the free surface reduces the surface waves. For explosions inside a mountain, displacement of the sides of the mountain reduces surface waves. Compressive prestress reduces surface waves substantially, while tensile prestress increases surface waves. The North Korean explosions appear to be at an optimal depth, in a region of extension, and beneath a mountain, all of which increase surface wave amplitudes.

  17. Extranodal Marginal Zone Lymphoma: No Longer Just a Sidekick.

    PubMed

    Kamdar, Manali K; Smith, Sonali M

    2017-06-10

    The Oncology Grand Rounds series is designed to place original reports published in the Journal into clinical context. A case presentation is followed by a description of diagnostic and management challenges, a review of the relevant literature, and a summary of the authors' suggested management approaches. The goal of this series is to help readers better understand how to apply the results of key studies, including those published in Journal of Clinical Oncology, to patients seen in their own clinical practice. A 51-year-old healthy female with good performance status presented for gynecologic surgery for a benign condition. A preprocedure chest x-ray showed a right lower lobe infiltrate. A subsequent computed tomography (CT) scan of the chest with contrast revealed a large consolidative right lower lobe mass with surrounding inflammation ( Fig 1A ). Bronchoscopy with biopsy revealed a low-grade lymphoma with the following immunophenotype: CD45 + , CD20 + , BCL2 + , CD10 negative, CD5 negative, cyclin D1 negative, and Ki-67 index of less than 5%. Morphology and immunohistochemistry were most consistent with pulmonary extranodal marginal zone lymphoma (ENMZL; Fig 2 ). The patient was asymptomatic and denied fevers, sweats, weight loss, shortness of breath or dyspnea on exertion, or cough. Her history was notable for exposure to parrots over several months before presentation. Complete staging with a CT of the chest, abdomen, and pelvis with contrast redemonstrated disease that was localized to the chest with mild compression of the pulmonary vasculature but no other evidence of lymphoma. She was referred to discuss management of stage I AE pulmonary ENMZL lymphoma.

  18. Predicted variation of stress orientation with depth near an active fault: application to the Cajon Pass Scientific Drillhole, southern California

    USGS Publications Warehouse

    Wesson, R.L.

    1988-01-01

    Preliminary measurements of the stress orientation at a depth of 2 km interpreted to indicate that the regional orientation of the maximum compression is normal to the fault, and taken as evidence for a very weak fault. The orientation expected from plate tectonic arguments is about 66?? NE from the strike of the fault. Geodetic data indicate that the orientation of maximum compressive strain rate is about 43?? NE from the strike of the fault, and show nearly pure right-lateral shear acting parallel to the fault. These apparent conflicts in the inferred orientation of the axis of maximum compression may be explained in part by a model in which the fault zone is locked over a depth interval in the range of 2-5 to 15 km, but is very weak above and below that interval. This solution does require, however, a few mm/yr of creep at the surface on the San Andreas or nearby sub-parallel faults (such as the San Jacinto), which has not yet been observed, or a shallow zone near the faults of distributed deformation. -from Author

  19. Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression

    NASA Astrophysics Data System (ADS)

    Collins, Cary A.; Lane, David; Frank, Mark S.; Hardy, Michael E.; Haynor, David R.; Smith, Donald V.; Parker, James E.; Bender, Gregory N.; Kim, Yongmin

    1994-04-01

    The digital archiving system at Madigan Army Medical Center (MAMC) uses a 10:1 lossy data compression algorithm for most forms of computed radiography. A systematic study on the potential effect of lossy image compression on patient care has been initiated with a series of studies focused on specific diagnostic tasks. The studies are based upon the receiver operating characteristic (ROC) method of analysis for diagnostic systems. The null hypothesis is that observer performance with approximately 10:1 compressed and decompressed images is not different from using original, uncompressed images for detecting subtle pathologic findings seen on computed radiographs of bone, chest, or abdomen, when viewed on a high-resolution monitor. Our design involves collecting cases from eight pathologic categories. Truth is determined by committee using confirmatory studies performed during routine clinical practice whenever possible. Software has been developed to aid in case collection and to allow reading of the cases for the study using stand-alone Siemens Litebox workstations. Data analysis uses two methods, ROC analysis and free-response ROC (FROC) methods. This study will be one of the largest ROC/FROC studies of its kind and could benefit clinical radiology practice using PACS technology. The study design and results from a pilot FROC study are presented.

  20. Compressive orthotic bracing in the treatment of pectus carinatum: the use of radiographic markers to predict success.

    PubMed

    Stephenson, Jacob T; Du Bois, Jeffrey

    2008-10-01

    The treatment of pectus carinatum (PC) has classically been operative, though compressive orthotic braces have been used with good success in recent years. The purpose of this article is to evaluate the use of radiologic measurements in a successful bracing protocol. Sixty-three patients with PC have been evaluated for an 8-year span. The average age is 13.3 +/- 2.5. Follow-up is from 4 to 60 months, with a median of 24 months. Seventeen patients with mild defects elected observation alone. The remaining 46 patients began the bracing protocol. Baseline chest computed tomography (CT) was obtained, and custom-fitted orthotic braces were constructed for each patient. Radiographic markers were evaluated to include the Haller index, angle of sternal rotation, and asymmetry index. Patient surveys and chart review were used to identify compliance and success rates. Pretreatment CTs were retrospectively reviewed by bracing outcomes and radiographic measurements were compared. Ten patients received posttreatment CTs after successful bracing. Of 63 patients with PC, 17 patients (27%) with mild defects elected observation alone. The remaining 46 patients began the bracing protocol as described above. Of these, 10 are excluded from analysis, with 6 patients currently in the early treatment phase and 4 who have been lost to follow-up. Of the remaining 36 patients, 8 failed bracing because of noncompliance. Of the 28, 24 patients who completed treatment report either good or excellent results after bracing. Eight patients have required surgical intervention, 4 as a result of noncompliance and 4 who were compliant but failed bracing. In patients who were compliant, significant differences were seen on initial CT between those with successful outcomes and those who required surgical repair. Haller index (2.85 vs 2.05; P < .05), angle of sternal rotation (27.3 vs 14.8; P < .05), and asymmetry index (1.23 vs 1.06; P < .01) were all higher in the group who failed bracing. In those who successfully completed treatment, there was no significant difference in the Haller or asymmetry indices, but the average improvement in sternal rotation was 53.8%. Compressive orthotic bracing is a successful method of treatment of pectus carinatum. The associated sternal rotation can be significantly improved with appropriate bracing that results in a subjective improvement in the deformity. Asymmetry of chest diameter related to concomitant excavatum-type deformity is less likely to respond to bracing attempts. In this way, initial chest CT can be of value in treatment planning.

  1. Problems and solutions: accounts by parents and children of adhering to chest physiotherapy for cystic fibrosis.

    PubMed

    Williams, Brian; Mukhopadhyay, Somnath; Dowell, Jon; Coyle, Joanne

    2007-07-30

    Although chest physiotherapy is central to the management of cystic fibrosis (CF), adherence among children is problematic. This study explores accounts by parents and children of the difficulties of adhering to chest physiotherapy for cystic fibrosis, and identifies strategies used by families to overcome these. A qualitative study based on in-depth interviews with 32 children with a diagnosis of cystic fibrosis aged 7 - 17 years, and with 31 parents. Physiotherapy was frequently described as restrictive, threatening to identity and boring, giving rise to feelings of unfairness, inequality, 'difference', and social stigma. Motivation to adhere was influenced by perceptions of effectiveness that depended on external signs evident during or after the physiotherapy. Motivation was enhanced where parents and children visualized the accumulation of mucus. Some parents had developed distraction techniques that improved the experience of chest physiotherapy but had few opportunities to share these with other parents. The experience of physiotherapy is problematic to some parents and children. Furthermore, motivation to overcome these problems may be undermined by perceptions of ineffectiveness. Distraction techniques that change the value that the child places on the time spent doing physiotherapy and that reduces their perception of its duration may improve experience and adherence. The potential of visualization techniques to promote adherence should be investigated further.

  2. Back pain in space and post-flight spine injury: Mechanisms and countermeasure development

    NASA Astrophysics Data System (ADS)

    Sayson, Jojo V.; Lotz, Jeffrey; Parazynski, Scott; Hargens, Alan R.

    2013-05-01

    During spaceflight many astronauts experience moderate to severe lumbar pain and deconditioning of paraspinal muscles. There is also a significant incidence of herniated nucleus pulposus (HNP) in astronauts post-flight being most prevalent in cervical discs. Relief of in-flight lumbar back pain is facilitated by assuming a knee-to-chest position. The pathogenesis of lumbar back pain during spaceflight is most likely discogenic and somatic referred (from the sinuvertebral nerves) due to supra-physiologic swelling of the lumbar intervertebral discs (IVDs) due to removal of gravitational compressive loads in microgravity. The knee-to-chest position may reduce lumbar back pain by redistributing stresses through compressive loading to the IVDs, possibly reducing disc volume by fluid outflow across IVD endplates. IVD stress redistribution may reduce Type IV mechanoreceptor nerve impulse propagation in the annulus fibrosus and vertebral endplate resulting in centrally mediated pain inhibition during spinal flexion. Countermeasures for lumbar back pain may include in-flight use of: (1) an axial compression harness to prevent excessive IVD expansion and spinal column elongation; (2) the use of an adjustable pulley exercise developed to prevent atrophy of spine muscle stabilisers; and (3) other exercises that provide Earth-like annular stress with low-load repetitive active spine rotation movements. The overall objective of these countermeasures is to promote IVD health and to prevent degenerative changes that may lead to HNPs post-flight. In response to "NASA's Critical Path Roadmap Risks and Questions" regarding disc injury and higher incidence of HNPs after space flight (Integrated Research Plan Gap-B4), future studies will incorporate pre- and post-flight imaging of International Space Station long-duration crew members to investigate mechanisms of lumbar back pain as well as degeneration and damage to spinal structures. Quantitative results on morphological, biochemical, metabolic, and kinematic spinal changes in the lumbar spine may aid further development of countermeasures to prevent lumbar back pain in microgravity and reduce the incidence of HNPs post-flight.

  3. Chest sonography detects lung water accumulation in healthy elite apnea divers.

    PubMed

    Frassi, Francesca; Pingitore, Alessandro; Cialoni, Danilo; Picano, Eugenio

    2008-10-01

    Ultrasound lung comets (ULCs) detected by chest sonography are a simple, noninvasive, semiquantitative sign of increased extravascular lung water. Pulmonary edema may occur in elite apnea divers, possibly triggered by centralization of blood flow from the periphery to pulmonary vessels. We assessed the prevalence of ULCs in top-level breath-hold divers after immersion. We evaluated 31 consecutive healthy, top-level, breath-hold divers (10 female, 21 male; age 31 +/- 5 years) participating in a yearly international apnea diving contest in Sharm-el-Sheik, Egypt, November 1 to 3, 2007. We performed chest and cardiac sonography with a transthoracic probe (2.5-3.5 MHz, Esaote Mylab) in all divers, both on the day before and 10 +/- 9 minutes after immersion. In a subset of 4 divers, chest scan was also repeated at 24 hours after immersion. ULCs were evaluated on the anterior and posterior chest at 61 predefined scanning sites. An independent sonographer, blind to both patient identity and status (pre- or post-diving), scored ULCs. Diving depth ranged from 31 to 112 m. Duration of immersion ranged from 120 to 225 seconds. The ULC score was 0.5 +/- 1.5 at baseline and 13 +/- 21 after diving (P = .012). At individual patient analysis, ULCs appeared in 14 athletes (45%) after diving. Of these 14 athletes, 4 were asymptomatic, 6 showed aspecific symptoms with transient loss of motor control ("Samba"), 2 had palpitations with frequent premature ventricular contractions, and 2 had persistent cough with hemoptysis and pulmonary crackles. In a subset of 4 athletes with post-diving ULCs in whom late follow-up study also was available, chest sonography findings fully normalized at 24 hours of follow-up. In top-level breath-hold divers, chest sonography frequently reveals an increased number of ULCs after immersion, indicating a relatively high prevalence of (often subclinical) reversible extravascular lung water accumulation.

  4. Pediatric constrictive asphyxia a rare form of child abuse: A report of two cases.

    PubMed

    Vester, M E M; Bilo, R A C; Nijs, H G T; van Rijn, R R

    2018-04-01

    We present two cases of infants who died under suspicious circumstances. After clinical and legal investigations, non-accidental constrictive asphyxia inflicted by one of the parents was established. The first case presents a to date not yet reported, unique mechanism of trauma. In order to stop his daughter from crying, the father admitted that he sometimes sat on his baby while she was lying on the bed. Occasionally increasing his force by pulling with his hands on the bottom of the bed. In the second case tight swaddling and encircling chest compression was the causative mechanism. In both cases the father was sentenced to imprisonment with mandate psychiatric care. Only two previous reports of this uncommon and relatively unknown cause of child abuse, called constrictive asphyxia, are known. In all reported cases static loading of the chest resulted in rib fractures and demise of the child. This rare abusive mechanism should be known to pediatric radiologists and pathologists. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Prevalence and hemodynamic effects of leaning during CPR

    PubMed Central

    Niles, Dana E.; Sutton, Robert M.; Nadkarni, Vinay M.; Glatz, Andrew; Zuercher, Mathias; Maltese, Matthew R.; Eilevstjønn, Joar; Abella, Benjamin S.; Becker, Lance B.; Berg, Robert A.

    2013-01-01

    Background Cardiopulmonary resuscitation (CPR) guidelines recommend complete release between chest compressions (CC). Objective Evaluate the hemodynamic effects of leaning (incomplete chest wall release) during CPR and the prevalence of leaning during CPR. Results In piglet ventricular fibrillation cardiac arrests, 10% and 20% (1.8 kg and 3.6 kg, respectively), leaning during CPR increased right atrial pressures, decreased coronary perfusion pressures, and decreased cardiac index and left ventricular myocardial blood flow by nearly 50%. In contrast, residual leaning of a 260 g accelerometer/ force feedback device did not adversely affect cardiac index or myocardial blood flow. Among 108 adult in-hospital CPR events, leaning ≥2.5 kg was demonstrable in 91% of the events and 12% of the evaluated CC. For 12 children with in-hospital CPR, 28% of CC had residual leaning ≥2.5 kg and 89% had residual leaning ≥0.5 kg. Conclusions Leaning during CPR increases intrathoracic pressure, decreases coronary perfusion pressure, and decreases cardiac output and myocardial blood flow. Leaning is common during CPR. PMID:22208173

  6. Massive Air Embolism During Interventional Laser Therapy of the Liver: Successful Resuscitation Without Chest Compression

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helmberger, Thomas K.; Roth, Ute; Empen, Klaus

    2002-08-15

    We report on a rare, acute, life-threatening complication during percutaneous thermal therapy for hepatic metastases. Massive cardiac air embolism occurred during a maneuver of deep inspiration after the dislodgement of an introducer sheath into a hepatic vein. The subsequent cardiac arrest was treated successfully by immediate transthoracic evacuation of the air by needle aspiration followed by electrical defibrillation. In procedures that may be complicated by gas embolism, cardiopulmonary resuscitation should not be initiated before considering the likelihood of air embolism, and eventually aspiration of the gas.

  7. Cardiopulmonary Resuscitation in Adults and Children With Mechanical Circulatory Support: A Scientific Statement From the American Heart Association.

    PubMed

    Peberdy, Mary Ann; Gluck, Jason A; Ornato, Joseph P; Bermudez, Christian A; Griffin, Russell E; Kasirajan, Vigneshwar; Kerber, Richard E; Lewis, Eldrin F; Link, Mark S; Miller, Corinne; Teuteberg, Jeffrey J; Thiagarajan, Ravi; Weiss, Robert M; O'Neil, Brian

    2017-06-13

    Cardiac arrest in patients on mechanical support is a new phenomenon brought about by the increased use of this therapy in patients with end-stage heart failure. This American Heart Association scientific statement highlights the recognition and treatment of cardiovascular collapse or cardiopulmonary arrest in an adult or pediatric patient who has a ventricular assist device or total artificial heart. Specific, expert consensus recommendations are provided for the role of external chest compressions in such patients. © 2017 American Heart Association, Inc.

  8. [The impact of 2010 international consensus on CPR and ECC science with treatment recommendations on Japan].

    PubMed

    Miyake, Yasufumi

    2011-04-01

    New guidelines on cardiopulmonary resuscitation(CPR) and emergency cardiovascular care (ECC) were published in October 2010 from International Liaison Committee on Resuscitation (ILCOR). Changes of these guidelines will have dramatic effects on Japan. Starting with chest compressions first will increase by-stander CPR. Cases of recovery of spontaneous heartbeat could increase as a result. Intensive care and radical treatments for cardiovascular emergency and brain damage after cardiopulmonary arrest would be essential. Education, implementation and teams (EIT) will be the third subject.

  9. [Polytrauma with tension pneumothorax with inserted chest tube].

    PubMed

    Genzwürker, H V; Volz, A; Isselhorst, C; Gieser, R; Neufang, T; Roth, H; Birmelin, M; Kerger, H

    2005-12-01

    The authors report a case of a 25-year-old woman with a polytrauma, caused by a free fall of 12 metres in suicidal intention. Following endotracheal intubation and mechanical ventilation by an emergency physician at the scene, the patient was delivered to the emergency room of an university hospital. An ultrasonic check of the abdomen revealed free fluid in the abdominal cavity, and a rupture of liver and spleen was suspected. Since breath sounds over the right lung were diminished, a chest tube was inserted immediately in the fifth intercostal space in the anterior axillary line. About 300 millilitres of blood were drained by the tube. Shortly thereafter, a laparotomy was performed, where spleen and liver rupture were confirmed and treated. After 60 minutes, the patient developed severe hypotension coupled with ventricular tachycardia and fibrillation, and resuscitation measures had to be initiated. Since breath sounds over the right lung were missing, a tension pneumothorax was suspected and a thoracotomy performed immediately. While huge amounts of air and blood were emerging from the thoracic cavity, a rupture of the right mainstem bronchus as well as of the right pulmonary artery and vena subclavia was identified. The chest tube was found dislocated into the subcutaneous tissue. Despite of open heart compression, application of adrenaline and noradrenaline and substitution of packed red blood cells and of crystalloid and colloid solutions, all resuscitation measures failed so that the patient died shortly after on the operation table. This case illustrates first the difficulties of an adequate thoracic trauma management, particularly, when clinical symptoms are discrete, second the problems of the insertion and control of a chest tube, and third risks associated with wrong position or secondary dislocation which may include - as in our case - "masking" of severe injury patterns and delay of life-saving measures such as an immediate thoracotomy. In order to improve prognosis of patients with poly-/thoracic trauma, establishment of spiral-CT in emergency centres, routine bronchoscopy and safe handling of chest tubes may be helpful.

  10. Validation of Monte Carlo simulation of mammography with TLD measurement and depth dose calculation with a detailed breast model

    NASA Astrophysics Data System (ADS)

    Wang, Wenjing; Qiu, Rui; Ren, Li; Liu, Huan; Wu, Zhen; Li, Chunyan; Li, Junli

    2017-09-01

    Mean glandular dose (MGD) is not only determined by the compressed breast thickness (CBT) and the glandular content, but also by the distribution of glandular tissues in breast. Depth dose inside the breast in mammography has been widely concerned as glandular dose decreases rapidly with increasing depth. In this study, an experiment using thermo luminescent dosimeters (TLDs) was carried out to validate Monte Carlo simulations of mammography. Percent depth doses (PDDs) at different depth values were measured inside simple breast phantoms of different thicknesses. The experimental values were well consistent with the values calculated by Geant4. Then a detailed breast model with a CBT of 4 cm and a glandular content of 50%, which has been constructed in previous work, was used to study the effects of the distribution of glandular tissues in breast with Geant4. The breast model was reversed in direction of compression to get a reverse model with a different distribution of glandular tissues. Depth dose distributions and glandular tissue dose conversion coefficients were calculated. It revealed that the conversion coefficients were about 10% larger when the breast model was reversed, for glandular tissues in the reverse model are concentrated in the upper part of the model.

  11. Blood Pressure Directed Booster Trainings Improve Intensive Care Unit Provider Retention of Excellent Cardiopulmonary Resuscitation Skills.

    PubMed

    Wolfe, Heather; Maltese, Matthew R; Niles, Dana E; Fischman, Elizabeth; Legkobitova, Veronika; Leffelman, Jessica; Berg, Robert A; Nadkarni, Vinay M; Sutton, Robert M

    2015-11-01

    Brief, intermittent cardiopulmonary resuscitation (CPR) training sessions, "Booster Trainings," improve CPR skill acquisition and short-term retention. The objective of this study was to incorporate arterial blood pressure (ABP) tracings into Booster Trainings to improve CPR skill retention. We hypothesized that ABP-directed CPR "Booster Trainings" would improve intensive care unit (ICU) provider 3-month retention of excellent CPR skills without need for interval retraining. A CPR manikin creating a realistic relationship between chest compression depth and ABP was used for training/testing. Thirty-six ICU providers were randomized to brief, bedside ABP-directed CPR manikin skill retrainings: (1) Booster Plus (ABP visible during training and testing) versus (2) Booster Alone (ABP visible only during training, not testing) versus (3) control (testing, no intervention). Subjects completed skill tests pretraining (baseline), immediately after training (acquisition), and then retention was assessed at 12 hours, 3 and 6 months. The primary outcome was retention of excellent CPR skills at 3 months. Excellent CPR was defined as systolic blood pressure of 100 mm Hg or higher and compression rate 100 to 120 per minute. Overall, 14 of 24 (58%) participants acquired excellent CPR skills after their initial training (Booster Plus 75% vs 50% Booster Alone, P = 0.21). Adjusted for age, ABP-trained providers were 5.2× more likely to perform excellent CPR after the initial training (95% confidence interval [95% CI], 1.3-21.2; P = 0.02), and to retain these skills at 12 hours (adjusted odds ratio, 4.4; 95% CI, 1.3-14.9; P = 0.018) and 3 months (adjusted odds ratio, 4.1; 95% CI, 1.2-13.9; P = 0.023) when compared to baseline performance. The ABP-directed CPR booster trainings improved ICU provider 3-month retention of excellent CPR skills without the need for interval retraining.

  12. [Defi catches on : Implementation of a curriculum for resuscitation in secondary schools].

    PubMed

    Wanke, Sebastian; Strack, Marian; Dählmann, Carsten; Kuhr, Kathrin; Zobel, Carsten; Reuter, Hannes

    2018-04-01

    Sudden cardiac arrest is still one of the most frequent causes of death. Teaching resuscitation in schools was already successfully implemented in Scandinavian countries. Following a recommendation of the conference of german stateministers of education in June 2014, additional tuition for resuscitation is to be implemented in german schools starting in seventh grade. The present study aimed to assess the level of knowledge of seventh grade students in the field of life support and to implement curricular standards for resuscitation courses in secondary schools. Using a standardized questionnaire, students in seventh grade of five schools in Cologne were interrogated about their knowledge on resuscitation and defibrillation. This assessment was taken as basis for developing a curricular teaching concept by the Cologne heart centre in cooperation with the department of biology and technical didactics at the University of Cologne. This tutorial concept was integrated in scholar plans for the first time in the school year 2014/2015. At the end of the school year the students' knowledge got reevaluated. As expected, the technical knowledge of the interviewed students is low, however confidence in their own abilities is high. Most of the interviewed persons would be willing to perform chest compressions (72,26%) and dare using an automated external defibrillator (AED, 64,38%). The exact position of defibrillator pads cannot be precisely indicated by most students (8,40%), compression point, -depth and -frequency are known by just one third of students. Already one-time performance of the live-saving lesson resulted in a clear increase of knowledge about resuscitation. The willingness to perform resuscitation measures and confidence in their own abilities are high in seventh grade students. Therefore, the recommendation of the conference of german stateministers of education in June 2014 addresses the right target group. Long-term success of the presented educational concept will be analysed and reported in a longitudinal study.

  13. High-frequency Pulse-compression Ultrasound Imaging with an Annular Array

    NASA Astrophysics Data System (ADS)

    Mamou, J.; Ketterling, J. A.; Silverman, R. H.

    High-frequency ultrasound (HFU) allows fine-resolution imaging at the expense of limited depth-of-field (DOF) and shallow acoustic penetration depth. Coded-excitation imaging permits a significant increase in the signal-to-noise ratio (SNR) and therefore, the acoustic penetration depth. A 17-MHz, five-element annular array with a focal length of 31 mm and a total aperture of 10 mm was fabricated using a 25-μm thick piezopolymer membrane. An optimized 8-μs linear chirp spanning 6.5-32 MHz was used to excite the transducer. After data acquisition, the received signals were linearly filtered by a compression filter and synthetically focused. To compare the chirp-array imaging method with conventional impulse imaging in terms of resolution, a 25-μm wire was scanned and the -6-dB axial and lateral resolutions were computed at depths ranging from 20.5 to 40.5 mm. A tissue-mimicking phantom containing 10-μm glass beads was scanned, and backscattered signals were analyzed to evaluate SNR and penetration depth. Finally, ex-vivo ophthalmic images were formed and chirp-coded images showed features that were not visible in conventional impulse images.

  14. Contralateral breast dose from chest wall and breast irradiation: local experience.

    PubMed

    Alzoubi, A S; Kandaiya, S; Shukri, A; Elsherbieny, E

    2010-06-01

    Second cancer induction in the contralateral breast (CB) is an issue of some concern in breast radiotherapy especially for women under the age of 45 years at the time of treatment. The CB dose from 2-field and 3-field techniques in post-mastectomy chest wall irradiations in an anthropomorphic phantom as well as in patients were measured using thermoluminescent dosimeters (TLDs) at the local radiotherapy center. Breast and chest wall radiotherapy treatments were planned conformally (3D-CRT) and delivered using 6-MV photons. The measured CB dose at the surface fell sharply with distance from the field edge. However, the average ratio of the measured to the calculated CB dose using the pencil beam algorithm at the surface was approximately 53%. The mean and median measured internal dose at the posterior border of CB in a phantom was 5.47+/-0.22 cGy and 5.44 cGy, respectively. The internal CB dose was relatively independent of depth. In the present study the internal CB dose is 2.1-4.1% of the prescribed dose which is comparable to the values reported by other authors.

  15. Probing softness of the parietal pleural surface at the micron scale

    PubMed Central

    Kim, Jae Hun; Butler, James P.; Loring, Stephen H.

    2011-01-01

    The pleural surfaces of the chest wall and lung slide against each other, lubricated by pleural fluid. During sliding motion of soft tissues, shear induced hydrodynamic pressure deforms the surfaces, promoting uniformity of the fluid layer thickness, thereby reducing friction. To assess pleural deformability at length scales comparable to pleural fluid thickness, we measured the modulus of the parietal pleura of rat chest wall using atomic force microscopy (AFM) to indent the pleural surface with spheres (radius 2.5 µm and 5 µm). The pleura exhibited two distinct indentation responses depending on location, reflecting either homogeneous or significantly heterogeneous tissue properties. We found an elastic modulus of 0.38–0.95 kPa, lower than the values measured using flat-ended cylinders > 100 µm radii (Gouldstone et al., 2003, Journal of Applied Physiology 95, 2345–2349). Interestingly, the pleura exhibited a three-fold higher modulus when probed using 2.5 µm vs. 5 µm spherical tips at the same normalized depth, confirming depth dependent inhomogeneous elastic properties. The observed softness of the pleura supports the hypothesis that unevenness of the pleural surface on this scale is smoothed by local hydrodynamic pressure. PMID:21820660

  16. Improving cardiopulmonary resuscitation with a CPR feedback device and refresher simulations (CPR CARES Study): a randomized clinical trial.

    PubMed

    Cheng, Adam; Brown, Linda L; Duff, Jonathan P; Davidson, Jennifer; Overly, Frank; Tofil, Nancy M; Peterson, Dawn T; White, Marjorie L; Bhanji, Farhan; Bank, Ilana; Gottesman, Ronald; Adler, Mark; Zhong, John; Grant, Vincent; Grant, David J; Sudikoff, Stephanie N; Marohn, Kimberly; Charnovich, Alex; Hunt, Elizabeth A; Kessler, David O; Wong, Hubert; Robertson, Nicola; Lin, Yiqun; Doan, Quynh; Duval-Arnould, Jordan M; Nadkarni, Vinay M

    2015-02-01

    The quality of cardiopulmonary resuscitation (CPR) affects hemodynamics, survival, and neurological outcomes following pediatric cardiopulmonary arrest (CPA). Most health care professionals fail to perform CPR within established American Heart Association guidelines. To determine whether "just-in-time" (JIT) CPR training with visual feedback (VisF) before CPA or real-time VisF during CPA improves the quality of chest compressions (CCs) during simulated CPA. Prospective, randomized, 2 × 2 factorial-design trial with explicit methods (July 1, 2012, to April 15, 2014) at 10 International Network for Simulation-Based Pediatric Innovation, Research, & Education (INSPIRE) institutions running a standardized simulated CPA scenario, including 324 CPR-certified health care professionals assigned to 3-person resuscitation teams (108 teams). Each team was randomized to 1 of 4 permutations, including JIT training vs no JIT training before CPA and real-time VisF vs no real-time VisF during simulated CPA. The proportion of CCs with depth exceeding 50 mm, the proportion of CPR time with a CC rate of 100 to 120 per minute, and CC fraction (percentage CPR time) during simulated CPA. The quality of CPR was poor in the control group, with 12.7% (95% CI, 5.2%-20.1%) mean depth compliance and 27.1% (95% CI, 14.2%-40.1%) mean rate compliance. JIT training compared with no JIT training improved depth compliance by 19.9% (95% CI, 11.1%-28.7%; P < .001) and rate compliance by 12.0% (95% CI, 0.8%-23.2%; P = .037). Visual feedback compared with no VisF improved depth compliance by 15.4% (95% CI, 6.6%-24.2%; P = .001) and rate compliance by 40.1% (95% CI, 28.8%-51.3%; P < .001). Neither intervention had a statistically significant effect on CC fraction, which was excellent (>89.0%) in all groups. Combining both interventions showed the highest compliance with American Heart Association guidelines but was not significantly better than either intervention in isolation. The quality of CPR provided by health care professionals is poor. Using novel and practical technology, JIT training before CPA or real-time VisF during CPA, alone or in combination, improves compliance with American Heart Association guidelines for CPR that are associated with better outcomes. clinicaltrials.gov Identifier: NCT02075450.

  17. Are calving interval, abortions, incidence of stillbirths and pre-weaning losses in Nguni cows associated with linear type traits?

    PubMed

    Zindove, T J; Chimonyo, M

    2015-09-01

    The association of six linear type traits with calving interval, abortions, incidence of stillbirths and pre-weaning losses in Nguni cows in semi-arid and sub-humid communal areas was investigated. It was hypothesised that the odds of a cow having caving interval greater than 1 year, aborting, experiencing stillbirths or losing a calf from calving to weaning decreased with increase in body depth, rump height, flank circumference, chest circumference, navel height and body length. Navel height was measured as the distance from the ground to the lowest point of the cow's belly bottom (navel). Data were collected from a total of 200 Nguni cows from two sites experiencing sub-humid and semi-arid environments (100 each) between May and June 2013. Cows in sub-humid regions were 2.57 times more likely to have a calving interval of 1 year than cows in semi-arid areas. As body depth increased, the number of calves lost by a cow before weaning decreased linearly (p < 0.05) in all parities except parity 4. Cows in semi-arid regions were 2.13 times more likely to lose a calf from calving to weaning. For each unit increase in body depth, the odds of a cow aborting decreased by 1.12 and the odds of a cow having stillbirth decreased by 1.15. Rump height, flank circumference, chest circumference, navel height and body length were not associated with calving interval, abortions, incidence of stillbirths and pre-weaning losses. It was, therefore, concluded that body depth influences calving interval, incidence of stillbirths and abortions in Nguni cows. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Mechanical-structural investigation of chemical strengthening aluminosilicate glass through introducing phosphorus pentoxide

    NASA Astrophysics Data System (ADS)

    Zeng, Huidan; Wang, Ling; Ye, Feng; Yang, Bin; Chen, Jianding; Chen, Guorong; Sun, Luyi

    2016-11-01

    Chemical strengthening of aluminosilicate glasses through K+-Na+ ion exchange has attracted tremendous attentions because of the accelerating demand for high strength and damage resistance glasses. However, a paramount challenge still exists to fabricate glasses with a higher strength and greater depth of ion-exchange layer. Herein, aluminosilicate glasses with different contents of P2O5 were prepared and the influence of P2O5 on the increased compressive stress and depth of ion-exchange layer was investigated by micro-Raman technique. It was noticed that the hardness, compressive stress, as well as the depth of ion-exchange layer substantially increased with an increasing concentration of P2O5 varied from 1 to 7 mol%. The obtained micro-Raman spectra confirmed the formation of relatively depolymerized silicate anions that accelerated the ion exchange. Phosphorus containing aluminosilicate glasses with a lower polymerization degree exhibited a higher strength and deeper depth of ion-exchange layer, which suggests that the phosphorus containing aluminosilicate glasses have promising applications in flat panel displays, windshields, and wafer sealing substrates.

  19. External cardiac compression may be harmful in some scenarios of pulseless electrical activity.

    PubMed

    Hogan, T S

    2012-10-01

    Pulseless electrical activity occurs when organised or semi-organised electrical activity of the heart persists but the product of systemic vascular resistance and the increase in systemic arterial flow generated by the ejection of the left venticular stroke volume is not sufficient to produce a clinically detectable pulse. Pulseless electrical activity encompasses a very heterogeneous variety of severe circulatory shock states ranging in severity from pseudo-cardiac arrest to effective cardiac arrest. Outcomes of cardiopulmonary resuscitation for pulseless electrical activity are generally poor. Impairment of cardiac filling is the limiting factor to cardiac output in many scenarios of pulseless electrical activity, including extreme vasodilatory shock states. There is no evidence that external cardiac compression can increase cardiac output when impaired cardiac filling is the limiting factor to cardiac output. If impaired cardiac filling is the limiting factor to cardiac output and the heart is effectively ejecting all the blood returning to it, then external cardiac compression can only increase cardiac output if it increases venous return and cardiac filling. Repeated cardiac compression asynchronous with the patient's cardiac cycle and raised mean intrathoracic pressure due to chest compression can be expected to reduce rather than to increase cardiac filling and therefore to reduce rather than to increase cardiac output in such circumstances. The hypothesis is proposed that the performance of external cardiac compression will have zero or negative effect on cardiac output in pulseless electrical activity when impaired cardiac filling is the limiting factor to cardiac output. External cardiac compression may be both directly and indirectly harmful to significant sub-groups of patients with pulseless electrical activity. We have neither evidence nor theory to provide comfort that external cardiac compression is not harmful in many scenarios of pulseless electrical activity. Investigation using a variety of animal models of pulseless electrical activity produced by different shock-inducing mechanisms is required to provide an evidence base for resuscitation guidelines. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Passive ultra-brief video training improves performance of compression-only cardiopulmonary resuscitation.

    PubMed

    Benoit, Justin L; Vogele, Jennifer; Hart, Kimberly W; Lindsell, Christopher J; McMullan, Jason T

    2017-06-01

    Bystander compression-only cardiopulmonary resuscitation (CPR) improves survival after out-of-hospital cardiac arrest. To broaden CPR training, 1-2min ultra-brief videos have been disseminated via the Internet and television. Our objective was to determine whether participants passively exposed to a televised ultra-brief video perform CPR better than unexposed controls. This before-and-after study was conducted with non-patients in an urban Emergency Department waiting room. The intervention was an ultra-brief CPR training video displayed via closed-circuit television 3-6 times/hour. Participants were unaware of the study and not told to watch the video. Pre-intervention, no video was displayed. Participants were asked to demonstrate compression-only CPR on a manikin. Performance was scored based on critical actions: check for responsiveness, call for help, begin compressions immediately, and correct hand placement, compression rate and depth. The primary outcome was the proportion of participants who performed all actions correctly. There were 50 control and 50 exposed participants. Mean age was 37, 51% were African-American, 52% were female, and 10% self-reported current CPR certification. There were no statistically significant differences in baseline characteristics between groups. The number of participants who performed all actions correctly was 0 (0%) control vs. 10 (20%) exposed (difference 20%, 95% confidence interval [CI] 8.9-31.1%, p<0.001). Correct compression rate and depth were 11 (22%) control vs. 22 (44%) exposed (22%, 95% CI 4.1-39.9%, p=0.019), and 5 (10%) control vs. 15 (30%) exposed (20%, 95% CI 4.8-35.2%, p=0.012), respectively. Passive ultra-brief video training is associated with improved performance of compression-only CPR. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A 76-year-old woman with anaemia and cardiomegaly.

    PubMed

    Oh, Jin Kyung; Park, Jae-Hyeong

    2017-12-01

    A 76-year-old woman was referred to our hospital due to further evaluation of anaemia. During the past 3 years, she had been treated for multiple spinal compression fractures with vertebroplasty. Her blood pressure was 90/50 mm Hg, heart rate 75 beats/min, body temperature 37.7°C and respiratory rate 20/min at admission.On blood sampling, her haemoglobin level was 5.2 g/dL and white cell count and platelet count 3.7 and 22×10 3 / µL, respectively. She was diagnosed with multiple myeloma after serial diagnostic workups. Because her chest radiography showed cardiomegaly and left-sided pleural effusion with small atelectasis, transthoracic echocardiography and contrast enhanced chest CT were performed (figure 1, see online supplementary video). DC1SP110.1136/heartjnl-2017-312087.supp1Supplementary video heartjnl;103/24/2009/F1F1F1Figure 1(A) Apical four-chamber view by transthoracic echocardiography and (B) the coronal image of contrast-enhanced  chest CT. Which of the following is the most likely diagnosis of the cystic lesion?AscitesPericardial cystPericardial effusionBronchogenic cystPleural effusion. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique

    PubMed Central

    Lamoureux, Lorissa; Radhakrishnan, Jeejabai; Gazmuri, Raúl J.

    2015-01-01

    A rat model of electrically-induced ventricular fibrillation followed by cardiac resuscitation using a closed chest technique that incorporates the basic components of cardiopulmonary resuscitation in humans is herein described. The model was developed in 1988 and has been used in approximately 70 peer-reviewed publications examining a myriad of resuscitation aspects including its physiology and pathophysiology, determinants of resuscitability, pharmacologic interventions, and even the effects of cell therapies. The model featured in this presentation includes: (1) vascular catheterization to measure aortic and right atrial pressures, to measure cardiac output by thermodilution, and to electrically induce ventricular fibrillation; and (2) tracheal intubation for positive pressure ventilation with oxygen enriched gas and assessment of the end-tidal CO2. A typical sequence of intervention entails: (1) electrical induction of ventricular fibrillation, (2) chest compression using a mechanical piston device concomitantly with positive pressure ventilation delivering oxygen-enriched gas, (3) electrical shocks to terminate ventricular fibrillation and reestablish cardiac activity, (4) assessment of post-resuscitation hemodynamic and metabolic function, and (5) assessment of survival and recovery of organ function. A robust inventory of measurements is available that includes – but is not limited to – hemodynamic, metabolic, and tissue measurements. The model has been highly effective in developing new resuscitation concepts and examining novel therapeutic interventions before their testing in larger and translationally more relevant animal models of cardiac arrest and resuscitation. PMID:25938619

  3. Frequency of rib and sternum fractures associated with out-of-hospital cardiopulmonary resuscitation is underestimated by conventional chest X-ray.

    PubMed

    Lederer, Wolfgang; Mair, Dieter; Rabl, Walter; Baubin, Michael

    2004-02-01

    Fractured ribs and sternum are frequent complications of thoracic compression during CPR in adults. This study was conducted to determine whether findings of plain chest radiography (CXR) correlate with post-mortem findings in patients who underwent cardiopulmonary resuscitation (CPR) after out-of-hospital cardiac arrest. CXR findings and autopsy results of CPR-related chest injuries comprising rib and sternum fractures were compared prospectively in 19 patients. Fractures were diagnosed in nine of 19 patients by means of radiology and in 18 of 19 patients by autopsy (rib fractures in 6/19 versus 17/19, P=0.002; sternum fractures in 5/19 versus in 9/19, P=0.227. The total number of isolated bone fractures detected by CXR was 18 (12 rib and six sternum fractures) and by autopsy 92 (83 rib and nine sternum fractures). The majority of rib fractures was located in the anterior part of the thoracic cage. Sternum fractures predominantly occurred in the lower third. Eight of 19 patients received either thrombolytic or antithrombotic treatment during CPR but no major bleeding complication associated with CPR was detected by autopsy. The findings of this study indicate that fractures associated with CPR are underreported in conventional radiographic investigations. No major bleeding complications related to CPR-associated fractures was detected.

  4. Effects of Cutting Edge Microgeometry on Residual Stress in Orthogonal Cutting of Inconel 718 by FEM.

    PubMed

    Shen, Qi; Liu, Zhanqiang; Hua, Yang; Zhao, Jinfu; Lv, Woyun; Mohsan, Aziz Ul Hassan

    2018-06-14

    Service performance of components such as fatigue life are dramatically influenced by the machined surface and subsurface residual stresses. This paper aims at achieving a better understanding of the influence of cutting edge microgeometry on machined surface residual stresses during orthogonal dry cutting of Inconel 718. Numerical and experimental investigations have been conducted in this research. The cutting edge microgeometry factors of average cutting edge radius S¯, form-factor K , and chamfer were investigated. An increasing trend for the magnitudes of both tensile and compressive residual stresses was observed by using larger S¯ or introducing a chamfer on the cutting edges. The ploughing depth has been predicted based on the stagnation zone. The increase of ploughing depth means that more material was ironed on the workpiece subsurface, which resulted in an increase in the compressive residual stress. The thermal loads were leading factors that affected the surface tensile residual stress. For the unsymmetrical honed cutting edge with K = 2, the friction between tool and workpiece and tensile residual stress tended to be high, while for the unsymmetrical honed cutting edge with K = 0.5, the high ploughing depth led to a higher compressive residual stress. This paper provides guidance for regulating machine-induced residual stress by edge preparation.

  5. Investigation of non-uniform airflow signal oscillation during high frequency chest compression

    PubMed Central

    Sohn, Kiwon; Warwick, Warren J; Lee, Yong W; Lee, Jongwon; Holte, James E

    2005-01-01

    Background High frequency chest compression (HFCC) is a useful and popular therapy for clearing bronchial airways of excessive or thicker mucus. Our observation of respiratory airflow of a subject during use of HFCC showed the airflow oscillation by HFCC was strongly influenced by the nonlinearity of the respiratory system. We used a computational model-based approach to analyse the respiratory airflow during use of HFCC. Methods The computational model, which is based on previous physiological studies and represented by an electrical circuit analogue, was used for simulation of in vivo protocol that shows the nonlinearity of the respiratory system. Besides, airflow was measured during use of HFCC. We compared the simulation results to either the measured data or the previous research, to understand and explain the observations. Results and discussion We could observe two important phenomena during respiration pertaining to the airflow signal oscillation generated by HFCC. The amplitudes of HFCC airflow signals varied depending on spontaneous airflow signals. We used the simulation results to investigate how the nonlinearity of airway resistance, lung capacitance, and inertance of air characterized the respiratory airflow. The simulation results indicated that lung capacitance or the inertance of air is also not a factor in the non-uniformity of HFCC airflow signals. Although not perfect, our circuit analogue model allows us to effectively simulate the nonlinear characteristics of the respiratory system. Conclusion We found that the amplitudes of HFCC airflow signals behave as a function of spontaneous airflow signals. This is due to the nonlinearity of the respiratory system, particularly variations in airway resistance. PMID:15904523

  6. A better understanding of ambulance personnel's attitude towards real-time resuscitation feedback.

    PubMed

    Brinkrolf, Peter; Lukas, Roman; Harding, Ulf; Thies, Sebastian; Gerss, Joachim; Van Aken, Hugo; Lemke, Hans; Schniedermeier, Udo; Bohn, Andreas

    2018-03-01

    High-quality chest compressions during cardiopulmonary resuscitation (CPR) play a significant role in surviving cardiac arrest. Chest-compression quality can be measured and corrected by real-time CPR feedback devices, which are not yet commonly used. This article looks at the acceptance of such systems in comparison of equipped and unequipped personnel. Two groups of emergency medical services' (EMS) personnel were interviewed using standardized questionnaires. The survey was conducted in the German cities Dortmund and Münster. Overall, 205 persons participated in the survey: 103 paramedics and emergency physicians from the Dortmund fire service and 102 personnel from the Münster service. The staff of the Dortmund service were not equipped with real-time feedback systems. The test group of equipped personnel of the ambulance service of Münster Fire brigade uses real-time feedback systems since 2007. What is the acceptance level of real-time feedback systems? Are there differences between equipped and unequipped personnel? The total sample is receptive towards real-time feedback systems. More than 80% deem the system useful. However, this study revealed concerns and prejudices by unequipped personnel. Negative ratings are significantly lower at the Münster site that is experienced with the use of the real-time feedback system in contrast to the Dortmund site where no such experience exists-the system's use in daily routine results in better evaluation than the expectations of unequipped personnel. Real-time feedback systems receive overall positive ratings. Prejudices and concerns seem to decrease with continued use of the system.

  7. Ventilation by high-frequency chest wall compression in dogs with normal lungs.

    PubMed

    Zidulka, A; Gross, D; Minami, H; Vartian, V; Chang, H K

    1983-06-01

    In 6 anesthetized and paralyzed supine dogs, ventilation by high-frequency chest wall compression (HFCWC) was accomplished by a piston pump rapidly oscillating the pressure in a modified double blood pressure cuff wrapped around the lower thorax. Testing applied frequencies at 3, 5, 8, and 11 Hz, applied peak cuff pressures ranged from 30 to 230 cmH2O. This produced swings of esophageal pressure as high as 18 cmH2O and peak oscillatory air flow ranging from 0.7 to 1.6 L/s. Oscillatory tidal volume declined with increasing frequency and ranged from a mean of 61 to 45 ml. After 30 min of applied HFCWC, arterial blood gas determinations revealed a mean PaCO2 of 29.3 mmHg at 5 Hz, 35 mmHg at 3 Hz, 36 mmHg at 8 Hz, and 51 mmHg at 11 Hz. Mean PaO2 improved from ventilator control values at 3 Hz, remained unchanged at 5 and 8 Hz, and declined at 11 Hz. In 2 dogs breathing spontaneously, HFCWC applied at 5 and 11 Hz resulted in a reduction in spontaneous minute ventilation, mainly by a reduction in spontaneous tidal volume, whereas arterial blood gas values changed slightly. One dog ceased to breath spontaneously within 5 min of application of HFCWC as the PaCO2 fell below control values. We conclude that in dogs with normal lungs, HFCWC may assist spontaneous ventilation. In paralyzed dogs, HFCWC may be of sufficient magnitude to cause hyperventilation.

  8. Comparison of Coopdech®, CoPilot®, Intubrite®, and Macintosh laryngoscopes for tracheal intubation during pediatric cardiopulmonary resuscitation: a randomized, controlled crossover simulation trial.

    PubMed

    Szarpak, Łukasz; Czyżewski, Łukasz; Truszewski, Zenon; Kurowski, Andrzej; Gaszyński, Tomasz

    2015-11-01

    The aim of the study was to compare the intubation times and success rates of various laryngoscopes during resuscitation in pediatric emergency intubation with uninterrupted chest compression on a standardized pediatric manikin model. This was a randomized crossover study with 107 paramedic participants. We compared times to successful intubation, intubation success rates, and glottic visibility using a Cormack-Lehane grade for Macintosh, Intubrite®, Coopdech®, and Copilot® laryngoscopes. One hundred seven paramedics (mean age 31.2 ± 7.5 years) routinely involved in the management of prehospital care participated in this study. Intubation success rates (overall effectiveness), which was the primary study endpoint, were highest for the Coopdech® and CoPilot® devices (100 %) and were lowest for Intubrite® (89.7 %, p < 0.001) and Macintosh (80.4 %, p < 0.001). The secondary study endpoint, time to first effective ventilation, was achieved fastest when using the Coopdech® laryngoscope (21.6 ± 6.2 s) and was significantly slower with all other devices (Intubrite® 25.4 ± 10.5 s, p = 0.006; CoPilot® 25.6 ± 7.4 s, p = 0.007; Macintosh 29.4 ± 8.2 s, p < 0.001). We conclude that in child simulations managed by paramedics, the Coopdech® and Copilot® video laryngoscopes performed better than the standard Macintosh or Intubrite® laryngoscopes for endotracheal intubation during child chest compression.

  9. Basic life support skills of high school students before and after cardiopulmonary resuscitation training: a longitudinal investigation.

    PubMed

    Meissner, Theresa M; Kloppe, Cordula; Hanefeld, Christoph

    2012-04-14

    Immediate bystander cardiopulmonary resuscitation (CPR) significantly improves survival after a sudden cardiopulmonary collapse. This study assessed the basic life support (BLS) knowledge and performance of high school students before and after CPR training. This study included 132 teenagers (mean age 14.6 ± 1.4 years). Students completed a two-hour training course that provided theoretical background on sudden cardiac death (SCD) and a hands-on CPR tutorial. They were asked to perform BLS on a manikin to simulate an SCD scenario before the training. Afterwards, participants encountered the same scenario and completed a questionnaire for self-assessment of their pre- and post-training confidence. Four months later, we assessed the knowledge retention rate of the participants with a BLS performance score. Before the training, 29.5% of students performed chest compressions as compared to 99.2% post-training (P < 0.05). At the four-month follow-up, 99% of students still performed correct chest compressions. The overall improvement, assessed by the BLS performance score, was also statistically significant (median of 4 and 10 pre- and post-training, respectively, P < 0.05). After the training, 99.2% stated that they felt confident about performing CPR, as compared to 26.9% (P < 0.05) before the training. BLS training in high school seems highly effective considering the minimal amount of previous knowledge the students possess. We observed significant improvement and a good retention rate four months after training. Increasing the number of trained students may minimize the reluctance to conduct bystander CPR and increase the number of positive outcomes after sudden cardiopulmonary collapse.

  10. Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes.

    PubMed

    Truszewski, Zenon; Czyzewski, Lukasz; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Madziala, Marcin; Szarpak, Lukasz

    2016-09-01

    The aim of the trial was to compare the time parameters for intubation with the use of the Macintosh (MAC) laryngoscope and Pentax AWS-S100 videolaryngoscope (AWS; Pentax Corporation, Tokyo, Japan) with and without chest compression (CC) by paramedics during simulated cardiopulmonary resuscitation in a cadaver model. This was a randomized crossover cadaver trial. Thirty-five paramedics with no experience in videolaryngoscopy participated in the study. They performed intubation in two emergency scenarios: scenario A, normal airway without CC; scenario B, normal airway with continuous CC. The median time to first ventilation with the use of the AWS and the MAC was similar in scenario A: 25 (IQR, 22-27) seconds vs. 24 (IQR, 22.5-26) seconds (P=.072). A statistically significant difference in TTFV between AWS and MAC was noticed in scenario B (P=.011). In scenario A, the first endotracheal intubation (ETI) attempt success rate was achieved in 97.1% with AWS compared with 94.3% with MAC (P=.43). In scenario B, the success rate after the first ETI attempt with the use of the different intubation methods varied and amounted to 88.6% vs. 77.1% for AWS and MAC, respectively (P=.002). The Pentax AWS offered a superior glottic view as compared with the MAC laryngoscope, which was associated with a higher intubation rate and a shorter intubation time during an uninterrupted CC scenario. However, in the scenario without CC, the results for AWS and MAC were comparable. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Low dose scatter correction for digital chest tomosynthesis

    NASA Astrophysics Data System (ADS)

    Inscoe, Christina R.; Wu, Gongting; Shan, Jing; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping

    2015-03-01

    Digital chest tomosynthesis (DCT) provides superior image quality and depth information for thoracic imaging at relatively low dose, though the presence of strong photon scatter degrades the image quality. In most chest radiography, anti-scatter grids are used. However, the grid also blocks a large fraction of the primary beam photons requiring a significantly higher imaging dose for patients. Previously, we have proposed an efficient low dose scatter correction technique using a primary beam sampling apparatus. We implemented the technique in stationary digital breast tomosynthesis, and found the method to be efficient in correcting patient-specific scatter with only 3% increase in dose. In this paper we reported the feasibility study of applying the same technique to chest tomosynthesis. This investigation was performed utilizing phantom and cadaver subjects. The method involves an initial tomosynthesis scan of the object. A lead plate with an array of holes, or primary sampling apparatus (PSA), was placed above the object. A second tomosynthesis scan was performed to measure the primary (scatter-free) transmission. This PSA data was used with the full-field projections to compute the scatter, which was then interpolated to full-field scatter maps unique to each projection angle. Full-field projection images were scatter corrected prior to reconstruction. Projections and reconstruction slices were evaluated and the correction method was found to be effective at improving image quality and practical for clinical implementation.

  12. Volume and tissue composition preserving deformation of breast CT images to simulate breast compression in mammographic imaging

    NASA Astrophysics Data System (ADS)

    Han, Tao; Chen, Lingyun; Lai, Chao-Jen; Liu, Xinming; Shen, Youtao; Zhong, Yuncheng; Ge, Shuaiping; Yi, Ying; Wang, Tianpeng; Shaw, Chris C.

    2009-02-01

    Images of mastectomy breast specimens have been acquired with a bench top experimental Cone beam CT (CBCT) system. The resulting images have been segmented to model an uncompressed breast for simulation of various CBCT techniques. To further simulate conventional or tomosynthesis mammographic imaging for comparison with the CBCT technique, a deformation technique was developed to convert the CT data for an uncompressed breast to a compressed breast without altering the breast volume or regional breast density. With this technique, 3D breast deformation is separated into two 2D deformations in coronal and axial views. To preserve the total breast volume and regional tissue composition, each 2D deformation step was achieved by altering the square pixels into rectangular ones with the pixel areas unchanged and resampling with the original square pixels using bilinear interpolation. The compression was modeled by first stretching the breast in the superior-inferior direction in the coronal view. The image data were first deformed by distorting the voxels with a uniform distortion ratio. These deformed data were then deformed again using distortion ratios varying with the breast thickness and re-sampled. The deformation procedures were applied in the axial view to stretch the breast in the chest wall to nipple direction while shrinking it in the mediolateral to lateral direction re-sampled and converted into data for uniform cubic voxels. Threshold segmentation was applied to the final deformed image data to obtain the 3D compressed breast model. Our results show that the original segmented CBCT image data were successfully converted into those for a compressed breast with the same volume and regional density preserved. Using this compressed breast model, conventional and tomosynthesis mammograms were simulated for comparison with CBCT.

  13. Blunt trauma to large vessels: a mathematical study

    PubMed Central

    Ismailov, Rovshan M; Shevchuk, Nikolai A; Schwerha, Joseph; Keller, Lawrence; Khusanov, Higmat

    2004-01-01

    Background Blunt trauma causes short-term compression of some or all parts of the chest, abdomen or pelvis and changes hemodynamics of the blood. Short-term compression caused by trauma also results in a short-term decrease in the diameter of blood vessels. It has been shown that with a sudden change in the diameter of a tube or in the direction of the flow, the slower-moving fluid near the wall stops or reverses direction, which is known as boundary layer separation (BLS). We hypothesized that a sudden change in the diameter of elastic vessel that results from compression may lead not only to BLS but also to other hemodynamic changes that can damage endothelium. Methods We applied Navier-Stokes, multiphase and boundary layer equations to examine such stress. The method of approximation to solve the BL equations was used. Experiments were conducted in an aerodynamic tube, where incident flow velocity and weight of carriage with particles before and after blowing were measured. Results We found that sudden compression resulting from trauma leads to (1) BLS on the curved surface of the vessel wall; (2) transfer of laminar boundary layer into turbulent boundary layer. Damage to the endothelium can occur if compression is at least 25% and velocity is greater than 2.4 m/s or if compression is at least 10% and velocity is greater than 2.9 m/s. Conclusion Our research may point up new ways of reducing the damage from blunt trauma to large vessels. It has the potential for improvement of safety features of motor vehicles. This work will better our understanding of the precise mechanics and critical variables involved in diagnosis and prevention of blunt trauma to large vessels. PMID:15153246

  14. Teaching basic life support: a prospective randomized study on low-cost training strategies in secondary schools.

    PubMed

    Van Raemdonck, Veerle; Monsieurs, Koenraad G; Aerenhouts, Dirk; De Martelaer, Kristine

    2014-08-01

    Cardiopulmonary resuscitation (CPR) training at school is recommended. Limited school resources prevent implementation. The learning efficacy of low-cost training strategies is unknown. To evaluate the efficacy of different CPR learning strategies using low-cost didactic tools. Children (n=593, 15-16 years) were randomized to four training conditions: (1) manikin+teacher instruction (control group), (2) manikin+video instruction, (3) foam dice+plastic bag+peer training+teacher instruction, and (4) foam dice+plastic bag+peer training+video instruction. After a 50 min training, a 3 min CPR test on a manikin was performed using SkillReporting Software (Laerdal, Norway), and repeated after 6 months. The data of children without previous CPR training were analysed. Analysis of variance and the χ-test assessed differences between groups. Complete data sets were available for 165 pupils. Initially, group 3 scored lower on the mean ventilation volume (P<0.05). The control group scored better than the alternative groups (P<0.05) on the mean compression rate. After 6 months, the differences disappeared. All groups scored equally on ventilation volume (P=0.12), compression depth (P=0.11), compression rate (P=0.10), correct hand position (P=0.46) and number of correct compressions (P=0.76). Ventilation volume was sufficient in 32% of the pupils, 18% had a correct compression depth and 59% had a correct compression rate. Training efficacy with low-cost equipment was not different from training with a manikin. The outcome for all training strategies was suboptimal. The basics of CPR can be taught with alternative equipment if manikins are not available.

  15. Vulnerability of the Superficial Zone of Immature Articular Cartilage to Compressive Injury

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rolauffs, R.; Muehleman, C; Li, J

    The zonal composition and functioning of adult articular cartilage causes depth-dependent responses to compressive injury. In immature cartilage, shear and compressive moduli as well as collagen and sulfated glycosaminoglycan (sGAG) content also vary with depth. However, there is little understanding of the depth-dependent damage caused by injury. Since injury to immature knee joints most often causes articular cartilage lesions, this study was undertaken to characterize the zonal dependence of biomechanical, biochemical, and matrix-associated changes caused by compressive injury. Disks from the superficial and deeper zones of bovine calves were biomechanically characterized. Injury to the disks was achieved by applying amore » final strain of 50% compression at 100%/second, followed by biomechanical recharacterization. Tissue compaction upon injury as well as sGAG density, sGAG loss, and biosynthesis were measured. Collagen fiber orientation and matrix damage were assessed using histology, diffraction-enhanced x-ray imaging, and texture analysis. Injured superficial zone disks showed surface disruption, tissue compaction by 20.3 {+-} 4.3% (mean {+-} SEM), and immediate biomechanical impairment that was revealed by a mean {+-} SEM decrease in dynamic stiffness to 7.1 {+-} 3.3% of the value before injury and equilibrium moduli that were below the level of detection. Tissue areas that appeared intact on histology showed clear textural alterations. Injured deeper zone disks showed collagen crimping but remained undamaged and biomechanically intact. Superficial zone disks did not lose sGAG immediately after injury, but lost 17.8 {+-} 1.4% of sGAG after 48 hours; deeper zone disks lost only 2.8 {+-} 0.3% of sGAG content. Biomechanical impairment was associated primarily with structural damage. The soft superficial zone of immature cartilage is vulnerable to compressive injury, causing superficial matrix disruption, extensive compaction, and textural alteration, which results in immediate loss of biomechanical function. In conjunction with delayed superficial sGAG loss, these changes may predispose the articular surface to further softening and tissue damage, thus increasing the risk of development of secondary osteoarthritis.« less

  16. The visual perception of exocentric distance in outdoor settings.

    PubMed

    Norman, J Farley; Adkins, Olivia C; Pedersen, Lauren E; Reyes, Cecia M; Wulff, Rachel A; Tungate, Alex

    2015-12-01

    The ability of 20 younger (mean age was 21.8years) and older adults (mean age was 71.5years) to visually perceive exocentric distances outdoors was evaluated. The observers adjusted the extent of in-depth spatial intervals until they appeared identical to fronto-parallel intervals of 4 and 8m. The frontal and in-depth intervals were viewed from a distance of 8m. Almost all of the observers' judgments were inaccurate and most reflected perceptual compressions in depth: e.g., an in-depth interval of 10m would appear to have the same extent as a physically smaller 8m frontal interval. Some observers' judgments, however, were consistent with perceptual expansions of in-depth intervals. No significant effects of age were obtained in the current study: both younger and older adults exhibited perceptual compressions and expansions of in-depth intervals. This outcome differs from that of a recent experiment conducted by our laboratory (Vision Research 109 (2015) 52-58) that found the judgments of younger adults to be less accurate than those of older adults. A comparison of the former and current results revealed that while older adults perform similarly outdoors and indoors, the accuracy of younger adults' exocentric judgements improves substantially in outdoor settings (so that the accuracy becomes similar to that exhibited by older adults). Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. The relation of mechanical properties of wood and nosebar pressure in the production of veneer

    Treesearch

    Charles W. McMillin

    1958-01-01

    Observations of checking frequency, depth of check penetration, veneer thickness, and surface quality were made at 20 machining conditions. An inverse relationship between depth of check and frequency of checking was established. The effect of cutting temperature was demonstrated, and strength in compression perpendicular to the grain, tension perpendicular to the...

  18. First in-situ monitoring of CO2 delivery to the mantle followed by compression melting, using synchrotron generated X-ray diffraction.

    NASA Astrophysics Data System (ADS)

    Hammouda, Tahar; Chantel, Julien; Manthilake, Geeth; Guignard, Jérémy; Crichton, Wilson; Gaillard, Fabrice

    2014-05-01

    Melting of peridotite + CO2 upon compression has been directly monitored in situ, for the first time. We have combined high pressure experiments in the multianvil apparatus with synchrotron-generated X-ray diffraction, in order to monitor sample decarbonation upon heating, followed by melting upon compression. Experiments were performed in the model system CaO-MgO-SiO2+CO2, using dolomite and silicates contained in graphite capsules as starting material. Save Al, starting composition was aimed at reproducing peridotitic system. The sample was first compressed at room temperature, then heated. Decarbonation was observed at 2.2 GPa and 1100°C. After further heating to 1300°C, pressure was increased. Melting was observed at 2.7 GPa, while temperature was kept at 1300°C. All transformations were followed using X-ray diffraction. Starting with silicate + carbonate mixtures, we were thus able to keep CO2 fluid in the experimental sample at high P and T, up to the solidus. Concerning carbon recycling at subduction zones, it is known that CO2 is a non-wetting fluid in silicate aggregates. Therefore, any CO2 resulting from carbonate breakdown likely remains trapped at grain corners either in the subducted lithosphere or in the mantle wedge before eventually being trapped in mantle minerals as fluid inclusions, due to dynamic recrystallization. In this way, CO2 released from the slab may be spread laterally due to mantle convection. Entrainment to further depths by deep subduction or in convection cells induces CO2 introduction to depth wherein the solidus can be crossed, due to pressure increase. The solidus corresponds to the so-called carbonate ledge, beyond which carbonatitic melts are produced. Therefore, compression melting of CO2-bearing lithologies is a way to produce carbonatitic melts at depths corresponding to about 80 km. This mechanism is a viable explanation for the observed geophysical anomalies, such as those revealed by electrical conductivity measurements.

  19. Compressive sensing of frequency-dependent seismic radiation from subduction zone megathrust ruptures

    PubMed Central

    Yao, Huajian; Shearer, Peter M.; Gerstoft, Peter

    2013-01-01

    Megathrust earthquakes rupture a broad zone of the subducting plate interface in both along-strike and along-dip directions. The along-dip rupture characteristics of megathrust events, e.g., their slip and energy radiation distribution, reflect depth-varying frictional properties of the slab interface. Here, we report high-resolution frequency-dependent seismic radiation of the four largest megathrust earthquakes in the past 10 y using a compressive-sensing (sparse source recovery) technique, resolving generally low-frequency radiation closer to the trench at shallower depths and high-frequency radiation farther from the trench at greater depths. Together with coseismic slip models and early aftershock locations, our results suggest depth-varying frictional properties at the subducting plate interfaces. The shallower portion of the slab interface (above ∼15 km) is frictionally stable or conditionally stable and is the source region for tsunami earthquakes with large coseismic slip, deficient high-frequency radiation, and few early aftershocks. The slab interface at intermediate depths (∼15–35 km) is the main unstable seismogenic zone for the nucleation of megathrust quakes, typically with large coseismic slip, abundant early aftershocks, and intermediate- to high-frequency radiation. The deeper portion of the slab interface (∼35–45 km) is seismically unstable, however with small coseismic slip, dominant high-frequency radiation, and relatively fewer aftershocks.

  20. Delivery of cardiopulmonary resuscitation in the microgravity environment

    NASA Technical Reports Server (NTRS)

    Barratt, M. R.; Billica, R. D.

    1992-01-01

    The microgravity environment presents several challenges for delivering effective cardiopulmonary resuscitation (CPR). Chest compressions must be driven by muscular force rather than by the weight of the rescuer's upper torso. Airway stabilization is influenced by the neutral body posture. Rescuers will consist of crew members of varying sizes and degrees of physical deconditioning from space flight. Several methods of CPR designed to accommodate these factors were tested in the one G environment, in parabolic flight, and on a recent shuttle flight. Methods: Utilizing study participants of varying sizes, different techniques of CPR delivery were evaluated using a recording CPR manikin to assess adequacy of compressive force and frequency. Under conditions of parabolic flight, methods tested included conventional positioning of rescuer and victim, free floating 'Heimlich type' compressions, straddling the patient with active and passive restraints, and utilizing a mechanical cardiac compression assist device (CCAD). Multiple restrain systems and ventilation methods were also assessed. Results: Delivery of effective CPR was possible in all configurations tested. Reliance on muscular force alone was quickly fatiguing to the rescuer. Effectiveness of CPR was dependent on technique, adequate restraint of the rescuer and patient, and rescuer size and preference. Free floating CPR was adequate but rapidly fatiguing. The CCAD was able to provide adequate compressive force but positioning was problematic. Conclusions: Delivery of effective CPR in microgravity will be dependent on adequate resuer and patient restraint, technique, and rescuer size and preference. Free floating CPR may be employed as a stop gap method until patient restraint is available. Development of an adequate CCAD would be desirable to compensate for the effects of deconditioning.

  1. On the relative importance of bending and compression in cervical spine bilateral facet dislocation.

    PubMed

    Nightingale, Roger W; Bass, Cameron R; Myers, Barry S

    2018-03-08

    Cervical bilateral facet dislocations are among the most devastating spine injuries in terms of likelihood of severe neurological sequelae. More than half of patients with tetraparesis had sustained some form of bilateral facet fracture dislocation. They can occur at any level of the sub-axial cervical spine, but predominate between C5 and C7. The mechanism of these injuries has long been thought to be forceful flexion of the chin towards the chest. This "hyperflexion" hypothesis comports well with intuition and it has become dogma in the clinical literature. However, biomechanical studies of the human cervical spine have had little success in producing this clinically common and devastating injury in a flexion mode of loading. The purpose of this manuscript is to review the clinical and engineering literature on the biomechanics of bilateral facet dislocations and to describe the mechanical reasons for the causal role of compression, and the limited role of head flexion, in producing bilateral facet dislocations. Bilateral facet dislocations have only been produced in experiments where compression is the primary loading mode. To date, no biomechanical study has produced bilateral facet dislocations in a whole spine by bending. Yet the notion that it is primarily a hyper-flexion injury persists in the clinical literature. Compression and compressive buckling are the primary causes of bilateral facet dislocations. It is important to stop using the hyper-flexion nomenclature to describe this class of cervical spines injuries because it may have a detrimental effect on designs for injury prevention. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Aspergillus epidural abscess in a patient with obstructive airway disease.

    PubMed Central

    Chee, Y. C.; Poh, S. C.

    1983-01-01

    A 54-year-old Chinese man with episodic bronchial asthma since 25 years of age was treated for pulmonary tuberculosis in 1976 because of left upper lobe lesions on chest radiograph. In 1981 he presented with an extradural mass compressing the thoracic spinal cord, thought to be tuberculosis but which on biopsy was found to be aspergillosis. Sputum culture, type on skin-prick reactivity and serum precipitating antibodies were positive for Aspergillus. Amphotericin B intravenously, then ketoconazole orally did not substantially improve his clinical course. He died about four months post-laminectomy. PMID:6866873

  3. Optimizing Survival Outcomes For Adult Patients With Nontraumatic Cardiac Arrest.

    PubMed

    Jung, Julianna

    2016-10-01

    Patient survival after cardiac arrest can be improved significantly with prompt and effective resuscitative care. This systematic review analyzes the basic life support factors that improve survival outcome, including chest compression technique and rapid defibrillation of shockable rhythms. For patients who are successfully resuscitated, comprehensive postresuscitation care is essential. Targeted temperature management is recommended for all patients who remain comatose, in addition to careful monitoring of oxygenation, hemodynamics, and cardiac rhythm. Management of cardiac arrest in circumstances such as pregnancy, pulmonary embolism, opioid overdose and other toxicologic causes, hypothermia, and coronary ischemia are also reviewed.

  4. SVC obstruction and stridor relieved by nasogastric tube insertion

    PubMed Central

    Molena, Emma J.; Krishnamoorthy, Ashwin; Praveen, Coimbatore

    2016-01-01

    Achalasia is an idiopathic motility disorder of the oesophagus of increasing incidence. It is characterized by aperistalsis of the lower oesophagus and failure of relaxation of the lower oesophageal sphincter. Patients classically present with chronic symptoms of dysphagia, chest pain, weight loss and regurgitation, and they commonly suffer pulmonary complications such as recurrent microaspiration of static, retained food contents of the upper oesophagus. However, it has also been described, uncommonly, to present with megaoesophagus and secondary tracheal compression. We present a case of megaoesophagus secondary to achalasia which presented with stridor and signs of acute superior vena caval obstruction. PMID:26933001

  5. European Guidelines for AP/PA chest X-rays: routinely satisfiable in a paediatric radiology division?

    PubMed

    Tschauner, Sebastian; Marterer, Robert; Gübitz, Michael; Kalmar, Peter I; Talakic, Emina; Weissensteiner, Sabine; Sorantin, Erich

    2016-02-01

    Accurate collimation helps to reduce unnecessary irradiation and improves radiographic image quality, which is especially important in the radiosensitive paediatric population. For AP/PA chest radiographs in children, a minimal field size (MinFS) from "just above the lung apices" to "T12/L1" with age-dependent tolerance is suggested by the 1996 European Commission (EC) guidelines, which were examined qualitatively and quantitatively at a paediatric radiology division. Five hundred ninety-eight unprocessed chest X-rays (45% boys, 55% girls; mean age 3.9 years, range 0-18 years) were analysed with a self-developed tool. Qualitative standards were assessed based on the EC guidelines, as well as the overexposed field size and needlessly irradiated tissue compared to the MinFS. While qualitative guideline recommendations were satisfied, mean overexposure of +45.1 ± 18.9% (range +10.2% to +107.9%) and tissue overexposure of +33.3 ± 13.3% were found. Only 4% (26/598) of the examined X-rays completely fulfilled the EC guidelines. This study presents a new chest radiography quality control tool which allows assessment of field sizes, distances, overexposures and quality parameters based on the EC guidelines. Utilising this tool, we detected inadequate field sizes, inspiration depths, and patient positioning. Furthermore, some debatable EC guideline aspects were revealed. • European Guidelines on X-ray quality recommend exposed field sizes for common examinations. • The major failing in paediatric radiographic imaging techniques is inappropriate field size. • Optimal handling of radiographic units can reduce radiation exposure to paediatric patients. • Constant quality control helps ensure optimal chest radiographic image acquisition in children.

  6. Thoracic skeletal morphology and high-altitude hypoxia in Andean prehistory.

    PubMed

    Weinstein, Karen J

    2007-09-01

    Living humans from the highland Andes exhibit antero-posteriorly and medio-laterally enlarged chests in response to high-altitude hypoxia. This study hypothesizes that morphological responses to high-altitude hypoxia should also be evident in pre-Contact Andean groups. Thoracic skeletal morphology in four groups of human skeletons (N = 347) are compared: two groups from coastal regions (Ancón, Peru, n = 79 and Arica, Chile, n = 123) and two groups from high altitudes (San Pedro de Atacama, Chile, n = 102 and Machu Picchu and Cuzco, Peru, n = 43). Osteometric variables that represent proportions of chest width and depth include sternal and clavicular lengths and breadths and rib length, curvature, and area. Each variable was measured relative to body size, transformed into logarithmic indices, and compared across sex-specific groups using ANOVA and Tukey multiple comparison tests. Atacama highlanders have the largest sternal and clavicular proportions and ribs with the greatest area and least amount of curvature, features that suggest an antero-posteriorly deep and mediolaterally wide thoracic skeleton. Ancón lowlanders exhibit proportions indicating narrower and shallower chests. Machu Picchu and Cuzco males cluster with the other highland group in rib curvature and area at the superior levels of the thorax, whereas chest proportions in Machu Picchu and Cuzco females resemble those of lowlanders. The variation in Machu Picchu and Cuzco males and females is interpreted as the result of population migrations. The presence of morphological traits indicative of enlarged chests in some highland individuals suggests that high-altitude hypoxia was an environmental stressor shaping the biology of highland Andean groups during the pre-Contact period. (c) 2007 Wiley-Liss, Inc.

  7. JPEG XS call for proposals subjective evaluations

    NASA Astrophysics Data System (ADS)

    McNally, David; Bruylants, Tim; Willème, Alexandre; Ebrahimi, Touradj; Schelkens, Peter; Macq, Benoit

    2017-09-01

    In March 2016 the Joint Photographic Experts Group (JPEG), formally known as ISO/IEC SC29 WG1, issued a call for proposals soliciting compression technologies for a low-latency, lightweight and visually transparent video compression scheme. Within the JPEG family of standards, this scheme was denominated JPEG XS. The subjective evaluation of visually lossless compressed video sequences at high resolutions and bit depths poses particular challenges. This paper describes the adopted procedures, the subjective evaluation setup, the evaluation process and summarizes the obtained results which were achieved in the context of the JPEG XS standardization process.

  8. Does a minimal invasive approach reduce anterior chest wall numbness and postoperative pain in plate fixation of clavicle fractures?

    PubMed

    Beirer, Marc; Postl, Lukas; Crönlein, Moritz; Siebenlist, Sebastian; Huber-Wagner, Stefan; Braun, Karl F; Biberthaler, Peter; Kirchhoff, Chlodwig

    2015-05-28

    Fractures of the clavicle present very common injuries with a peak of incidence in young active patients. Recently published randomized clinical trials demonstrated an improved functional outcome and a lower rate of nonunions in comparison to non-operative treatment. Anterior chest wall numbness due to injury of the supraclavicular nerve and postoperative pain constitute common surgery related complications in plate fixation of displaced clavicle fractures. We recently developed a technique for mini open plating (MOP) of the clavicle to reduce postoperative numbness and pain. The purpose of this study was to analyze the size of anterior chest wall numbness and the intensity of postoperative pain in MOP in comparison to conventional open plating (COP) of clavicle fractures. 24 patients (mean age 38.2 ± 14.2 yrs.) with a displaced fracture of the clavicle (Orthopaedic Trauma Association B1.2-C1.2) surgically treated using a locking compression plate (LCP) were enrolled. 12 patients underwent MOP and another 12 patients COP. Anterior chest wall numbness was measured with a transparency grid on the second postoperative day and at the six months follow-up. Postoperative pain was evaluated using the Visual Analog Scale (VAS). Mean ratio of skin incision length to plate length was 0.61 ± 0.04 in the MOP group and 0.85 ± 0.06 in the COP group (p < 0.05). Mean ratio of the area of anterior chest wall numbness to plate length was postoperative 7.6 ± 5.9 (six months follow-up 4.7 ± 3.9) in the MOP group and 22.1 ± 19.1 (16.9 ± 14.1) in the COP group (p < 0.05). Mean VAS was 2.6 ± 1.4 points in the MOP group and 3.4 ± 1.6 points in the COP group (p = 0.20). In our study, MOP significantly reduced anterior chest wall numbness in comparison to a conventional open approach postoperative as well as at the six months follow-up. Postoperative pain tended to be lower in the MOP group, however this difference was not statistically significant. ClinicalTrials.gov NCT02247778 . Registered 21 September 2014.

  9. Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling

    PubMed Central

    Schulz-Drost, Stefan; Oppel, Pascal; Grupp, Sina; Schmitt, Sonja; Carbon, Roman Th.; Mauerer, Andreas; Hennig, Friedrich F.; Buder, Thomas

    2015-01-01

    Different ways to stabilize a sternal fracture are described in literature. Respecting different mechanisms of trauma such as the direct impact to the anterior chest wall or the flexion-compression injury of the trunk, there is a need to retain each sternal fragment in the correct position while neutralizing shearing forces to the sternum. Anterior sternal plating provides the best stability and is therefore increasingly used in most cases. However, many surgeons are reluctant to perform sternal osteosynthesis due to possible complications such as difficulties in preoperative planning, severe injuries to mediastinal organs, or failure of the performed method. This manuscript describes one possible safe way to stabilize different types of sternal fractures in a step by step guidance for anterior sternal plating using low profile locking titanium plates. Before surgical treatment, a detailed survey of the patient and a three dimensional reconstructed computed tomography is taken out to get detailed information of the fracture’s morphology. The surgical approach is usually a midline incision. Its position can be described by measuring the distance from upper sternal edge to the fracture and its length can be approximated by the summation of 60 mm for the basis incision, the thickness of presternal soft tissue and the greatest distance between the fragments in case of multiple fractures. Performing subperiosteal dissection along the sternum while reducing the fracture, using depth limited drilling, and fixing the plates prevents injuries to mediastinal organs and vessels. Transverse fractures and oblique fractures at the corpus sterni are plated longitudinally, whereas oblique fractures of manubrium, sternocostal separation and any longitudinally fracture needs to be stabilized by a transverse plate from rib to sternum to rib. Usually the high convenience of a patient is seen during follow up as well as a precise reconstruction of the sternal morphology. PMID:25590989

  10. A rare postoperative complication of anterior lower thoracic instrumentation: diaphragmatic laceration with hemothorax.

    PubMed

    Wong, Yat Wa; Cheung, Jason Pui Yin; Luk, Keith Dip Kei; Cheung, Kenneth Man Chee

    2017-05-01

    To highlight the importance of preventing visceral injury due to prominent anterior implants at the spinal column. A 52-year-old man with cord compression was treated with a T9/10 discectomy and instrumented fusion via a right thoracotomy and trans-pleural approach. Postoperatively, he had improved lower limb numbness. However, after a bout of coughing, there was sudden increase in chest drain output, hemodynamic instability and massive fluid collection in the right chest cavity. Emergency re-exploration of the thoracotomy was performed and a 6 cm laceration of the right postero-medial diaphragm was identified as the bleeding source and was found to be in close proximity with the locking nut of the anterior implants. The laceration was repaired and a soft synthetic patch was used to cover the implants. Postoperatively, the hemothorax resolved and the patient recovered from the neurological deficit. Prevention of diaphragmatic injury can be performed using lower profile and less sharp-edged implants. Implant coverage with a soft synthetic material is necessary if unable to perform direct repair of the parietal pleura over the implants.

  11. Forced expiratory technique, directed cough, and autogenic drainage.

    PubMed

    Fink, James B

    2007-09-01

    In health, secretions produced in the respiratory tract are cleared by mucociliary transport, cephalad airflow bias, and cough. In disease, increased secretion viscosity and volume, dyskinesia of the cilia, and ineffective cough combine to reduce secretion clearance, leading to increased risk of infection. In obstructive lung disease these conditions are further complicated by early collapse of airways, due to airway compression, which traps both gas and secretions. Techniques have been developed to optimize expiratory flow and promote airway clearance. Directed cough, forced expiratory technique, active cycle of breathing, and autogenic drainage are all more effective than placebo and comparable in therapeutic effects to postural drainage; they require no special equipment or care-provider assistance for routine use. Researchers have suggested that standard chest physical therapy with active cycle of breathing and forced expiratory technique is more effective than chest physical therapy alone. Evidence-based reviews have suggested that, though successful adoption of techniques such as autogenic drainage may require greater control and training, patients with long-term secretion management problems should be taught as many of these techniques as they can master for adoption in their therapeutic routines.

  12. Pectus carinatum.

    PubMed

    Coelho, Marlos de Souza; Guimarães, Paulo de Souza Fonseca

    2007-01-01

    Among the deformities of the thoracic wall,pectus carinatum has not received the same attention as has pectus excavatum. Few pulmonologists, pediatricians, and thoracic surgeons are aware of the approaches to treating this condition. As a consequence, patients with pectus carinatum are not referred for treatment. This deformity, with an incidence of 1:1000 teenagers, is oligosymptomatic. However, for aesthetic and emotional reasons, it accounts for a large number of medical appointments. Such patients are introverted and do not engage in physical activities, since they are unwilling to expose their chest, which also discourages them from going to the beach or to swimming pools. The diagnosis is clinical and visual, and details are obtained through chest X-rays and computed tomography. The treatment is based on a well-known organogram that summarizes orthopedic and surgical procedures. Dynamic compression, combined with physical exercises, is indicated for teenagers with flexible thorax in inferior and lateral pectus carinatum, with limited indication for those with superior pectus carinatum. For individuals of any age with rigid thorax, surgery is indicated for aesthetic reasons. Among the techniques described, the modified sternum chondroplasty stands out due to the excellent aesthetic results achieved.

  13. The benefits of a simplified method for CPR training of medical professionals: a randomized controlled study.

    PubMed

    Allan, Katherine S; Wong, Natalie; Aves, Theresa; Dorian, Paul

    2013-08-01

    We developed and tested a training method for basic life support incorporating defibrillator feedback during simulated cardiac arrest (CA) to determine the impact on the quality and retention of CPR skills. 298 subjects were randomized into 3 groups. All groups received a 2h training session followed by a simulated CA test scenario, immediately after training and at 3 months. Controls used a non-feedback defibrillator during training and testing. Group 1 was trained and tested with an audiovisual feedback defibrillator. During training, Group 1 reviewed quantitative CPR data from the defibrillator. Group 2 was trained as per Group 1, but was tested using the non-feedback defibrillator. The primary outcome was difference in compression depth between groups at initial testing. Secondary outcomes included differences in rate, depth at retesting, compression fraction, and self-assessment. Groups 1 and 2 had significantly deeper compressions than the controls (35.3 ± 7.6 mm, 43.7 ± 5.8 mm, 42.2 ± 6.6 mm for controls, Groups 1 and 2, P=0.001 for Group 1 vs. controls; P=0.001 for Group 2 vs. controls). At three months, CPR depth was maintained in all groups but remained significantly higher in Group 1 (39.1 ± 9.9 mm, 47.0 ± 7.4 mm, 42.2 ± 8.4 mm for controls, Groups 1 and 2, P=0.001 for Group 1 vs. control). No significant differences were noted between groups in compression rate or fraction. A simplified 2h training method using audiovisual feedback combined with quantitative review of CPR performance improved CPR quality and retention of these skills. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Depth-Dependent Transverse Shear Properties of the Human Corneal Stroma

    PubMed Central

    Petsche, Steven J.; Chernyak, Dimitri; Martiz, Jaime; Levenston, Marc E.

    2012-01-01

    Purpose. To measure the transverse shear modulus of the human corneal stroma and its profile through the depth by mechanical testing, and to assess the validity of the hypothesis that the shear modulus will be greater in the anterior third due to increased interweaving of lamellae. Methods. Torsional rheometry was used to measure the transverse shear properties of 6 mm diameter buttons of matched human cadaver cornea pairs. One cornea from each pair was cut into thirds through the thickness with a femtosecond laser and each stromal third was tested individually. The remaining intact corneas were tested to measure full stroma shear modulus. The shear modulus from a 1% shear strain oscillatory test was measured at various levels of axial compression for all samples. Results. After controlling for axial compression, the transverse shear moduli of isolated anterior layers were significantly higher than central and posterior layers. Mean modulus values at 0% axial strain were 7.71 ± 6.34 kPa in the anterior, 1.99 ± 0.45 kPa in the center, 1.31 ± 1.01 kPa in the posterior, and 9.48 ± 2.92 kPa for full thickness samples. A mean equilibrium compressive modulus of 38.7 ± 8.6 kPa at 0% axial strain was calculated from axial compression measured during the shear tests. Conclusions. Transverse shear moduli are two to three orders of magnitude lower than tensile moduli reported in the literature. The profile of shear moduli through the depth displayed a significant increase from posterior to anterior. This gradient supports the hypothesis and corresponds to the gradient of interwoven lamellae seen in imaging of stromal cross-sections. PMID:22205608

  15. Journal of Special Operation Medicine: A Peer Reviewed Journal for SOF Medical Professionals. Training Supplement, Winter 10

    DTIC Science & Technology

    2010-01-01

    anaphylactic reaction, spontaneous pneumothorax, HAPE, and pulmonary embolism . DISPOSITION: 1. Urgent evacuation if no response to treatment. 2. If...syndrome may present with chest pain, dyspnea, mediastinal emphysema, subcutaneous emphysema, pneumothorax, and arterial gas embolism (AGE...breathed at depth followed by ascending with a closed airway (i.e. breath-holding), and can cause pneumothorax or arterial gas embolism . Winter 2010

  16. Quantitative analysis of CPR quality during in-hospital resuscitation of older children and adolescents.

    PubMed

    Sutton, Robert M; Niles, Dana; Nysaether, Jon; Abella, Benjamin S; Arbogast, Kristy B; Nishisaki, Akira; Maltese, Matthew R; Donoghue, Aaron; Bishnoi, Ram; Helfaer, Mark A; Myklebust, Helge; Nadkarni, Vinay

    2009-08-01

    Few data exist on pediatric cardiopulmonary resuscitation (CPR) quality. This study is the first to evaluate actual in-hospital pediatric CPR. We hypothesized that with bedside CPR training and corrective feedback, CPR quality can approach American Heart Association (AHA) targets. Using CPR recording/feedback defibrillators, quality of CPR was assessed for patients >or=8 years of age who suffered a cardiac arrest in the PICU or emergency department (ED). Before and during the study, a bedside CPR training program was initiated. Between October 2006 and February 2008, twenty events in 18 patients met inclusion criteria and resulted in 36749 evaluable chest compressions (CCs) during 392.3 minutes of arrest. CCs were shallow (<38 mm or <1.5 in) in 27.2% (9998 of 36749), with excessive residual leaning force (>or=2500 g) in 23.4% (8611 of 36749). Segmental analysis of the first 5 minutes of the events demonstrated that shallow CCs and excessive residual leaning force were less prevalent during the first 5 minutes. AHA targets were not achieved for CC rate in 62 (43.1%) of 144 segments, CC depth in 52 (36.1%) of 144 segments, and residual leaning force in 53 (36.8%) of 144 segments. This prospective, observational study demonstrates feasibility of monitoring in-hospital pediatric CPR. Even with bedside CPR retraining and corrective audiovisual feedback, CPR quality frequently did not meet AHA targets. Importantly, no flow fraction target of 10% was achieved. Future studies should investigate novel educational methods and targeted feedback technologies.

  17. Echocardiographic image of an active human heart

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Echocardiographic images provide quick, safe images of the heart as it beats. While a state-of-the art echocardiograph unit is part of the Human Research Facility on International Space Station, quick transmission of images and data to Earth is a challenge. NASA is developing techniques to improve the echocardiography available to diagnose sick astronauts as well as study the long-term effects of space travel on their health. Echocardiography uses ultrasound, generated in a sensor head placed against the patient's chest, to produce images of the structure of the heart walls and valves. However, ultrasonic imaging creates an enormous volume of data, up to 220 million bits per second. This can challenge ISS communications as well as Earth-based providers. Compressing data for rapid transmission back to Earth can degrade the quality of the images. Researchers at the Cleveland Clinic Foundation are working with NASA to develop compression techniques that meet imaging standards now used on the Internet and by the medical community, and that ensure that physicians receive quality diagnostic images.

  18. Atypical Distant Metastasis of Breast Malignant Phyllodes Tumors: A Case Report and Literature Review.

    PubMed

    de Foucher, Tiphaine; Roussel, Hélène; Hivelin, Mikael; Rossi, Léa; Cornou, Caroline; Bats, Anne-Sophie; Deloménie, Myriam; Lécuru, Fabrice; Ngô, Charlotte

    2017-01-01

    Malignant phyllodes tumors (MPT) are rare breast neoplasms. Preoperative diagnosis is often challenging due to the unspecific clinical, radiological, and histological characteristics of the tumor. Dissemination pathways are local with chest wall invasion, regional with lymph nodes metastasis, and distant, hematogenous, mostly to the lungs, bones, and brain. Distant metastasis (DM) can be synchronous or appear months to years after the diagnosis and initial management. The current report describes the case of a 57-year-old woman presenting with a giant/neglected MPT of the breast, with no DM at initial staging, treated by radical modified mastectomy. Motor disorders due to medullar compression by a paravertebral mass appeared at short follow-up, also treated surgically. The patient died from several DM of rapid evolution. To our knowledge, this is the only case described of MPT with metastases to soft tissue causing medullar compression. We present a literature review on unusual metastatic localizations of MPT.

  19. Biomechanics of 4-point seat belt systems in frontal impacts.

    PubMed

    Rouhana, Stephen W; Bedewi, Paul G; Kankanala, Sundeep V; Prasad, Priya; Zwolinski, Joseph J; Meduvsky, Alex G; Rupp, Jonathan D; Jeffreys, Thomas A; Schneider, Lawrence W

    2003-01-01

    The biomechanical behavior of 4-point seat belt systems was investigated through MADYMO modeling, dummy tests and post mortem human subject tests. This study was conducted to assess the effect of 4-point seat belts on the risk of thoracic injury in frontal impacts, to evaluate the ability to prevent submarining under the lap belt using 4-point seat belts, and to examine whether 4-point belts may induce injuries not typically observed with 3-point seat belts. The performance of two types of 4-point seat belts was compared with that of a pretensioned, load-limited, 3-point seat belt. A 3-point belt with an extra shoulder belt that "crisscrossed" the chest (X4) appeared to add constraint to the torso and increased chest deflection and injury risk. Harness style shoulder belts (V4) loaded the body in a different biomechanical manner than 3-point and X4 belts. The V4 belt appeared to shift load to the clavicles and pelvis and to reduce traction of the shoulder belt across the chest, resulting in a reduction in chest deflection by a factor of two. This is associated with a 5 to 500-fold reduction in thoracic injury risk, depending on whether one assumes 4-point belts apply concentrated or distributed load. In four of six post mortem human subjects restrained by V4 belts during 40 km/h sled tests, chest compression was zero or negative and rib fractures were nearly eliminated. Submarining was not observed in any test with post mortem human subjects. Though lumbar, sacral and pelvic injuries were noted, they are believed to be due to the artificial restraint environment (no knee bolsters, instrument panels, steering systems or airbags). While they show significant potential to reduce thoracic injury risk, there are still many issues to be resolved before 4-point belts can be considered for production vehicles. These issues include, among others, potential effects on hard and soft neck tissues, of interaction with inboard shoulder belts in farside impacts and potential effects on the fetus of latch/buckle junctions at the centerline of pregnant occupants. Work continues at Ford Motor Company to resolve these issues.

  20. Challenges in diagnosis and management of giant solitary fibrous tumour of pleura: a case report.

    PubMed

    Tan, Jessica H Y; Hsu, Anne A L

    2016-08-08

    Majority of patients with solitary fibrous tumours of the pleura (SFTP) are asymptomatic. Acute presentation with symptoms resulting from mass effect due to rapid expansion of tumour size has not been reported before. This report chronicles the case of a giant SFTP in a 76-year-old lady who presented with acute onset of haemoptysis, left-sided pleuritic chest pain and hoarseness of voice. Her chest radiograph showed a large left upper hemithorax mass with an ipsilateral effusion. Computed tomography (CT) scan of the thorax confirmed the presence of a pleural-based mass lesion in the left apex measuring 9.7 cm with close apposition to the aortic arch. The mass demonstrated neovascularization and there was also presence of a moderate-sized heterogeneous-appearing left pleural effusion. Thoracocentesis yielded deeply haemoserous pleural fluid with a pleural aspirate hematocrit closely approaching that of peripheral blood hematocrit and alongside a 2 unit decrease in haemoglobin, was indicative of a haemothorax. Repeat CT 10 days from initial presentation showed reduction in size of the left apical mass as well as resolution of the left effusion. This was consistent with the occurrence of an intra-tumoural bleed resulting in rapid increase in the size of the SFTP, causing rupture of superficial blood vessels on the tumour surface (haemothorax) and consequential compression of the lung parenchyma (haemoptysis) and left recurrent laryngeal nerve (hoarseness of voice). The patient eventually underwent an uneventful surgical resection. A benign SFTP can present acutely with compressive symptoms as a result of spontaneous intra-tumoural bleed causing sudden increase in its size. It is important to allow temporal regression of these acute changes before deciding on surgical resectability.

Top