Update on mechanical cardiopulmonary resuscitation devices.
Rubertsson, Sten
2016-06-01
The aim of this review is to update and discuss the use of mechanical chest compression devices in treatment of cardiac arrest. Three recently published large multicenter randomized trials have not been able to show any improved outcome in adult out-of-hospital cardiac arrest patients when compared with manual chest compressions. Mechanical chest compression devices have been developed to better deliver uninterrupted chest compressions of good quality. Prospective large randomized studies have not been able to prove a better outcome compared to manual chest compressions; however, latest guidelines support their use when high-quality manual chest compressions cannot be delivered. Mechanical chest compressions can also be preferred during transportation, in the cath-lab and as a bridge to more invasive support like extracorporeal membrane oxygenation.
Eichhorn, S; Mendoza Garcia, A; Polski, M; Spindler, J; Stroh, A; Heller, M; Lange, R; Krane, M
2017-06-01
The provision of sufficient chest compression is among the most important factors influencing patient survival during cardiopulmonary resuscitation (CPR). One approach to optimize the quality of chest compressions is to use mechanical-resuscitation devices. The aim of this study was to compare a new device for chest compression (corpuls cpr) with an established device (LUCAS II). We used a mechanical thorax model consisting of a chest with variable stiffness and an integrated heart chamber which generated blood flow dependent on the compression depth and waveform. The method of blood-flow generation could be changed between direct cardiac-compression mode and thoracic-pump mode. Different chest-stiffness settings and compression modes were tested to generate various blood-flow profiles. Additionally, an endurance test at high stiffness was performed to measure overall performance and compression consistency. Both resuscitation machines were able to compress the model thorax with a frequency of 100/min and a depth of 5 cm, independent of the chosen chest stiffness. Both devices passed the endurance test without difficulty. The corpuls cpr device was able to generate about 10-40% more blood flow than the LUCAS II device, depending on the model settings. In most scenarios, the corpuls cpr device also generated a higher blood pressure than the LUCAS II. The peak compression forces during CPR were about 30% higher using the corpuls cpr device than with the LUCAS II. In this study, the corpuls cpr device had improved blood flow and pressure outcomes than the LUCAS II device. Further examination in an animal model is required to prove the findings of this preliminary study.
Yeung, Joyce; Davies, Robin; Gao, Fang; Perkins, Gavin D
2014-04-01
This study aims to compare the effect of three CPR prompt and feedback devices on quality of chest compressions amongst healthcare providers. A single blinded, randomised controlled trial compared a pressure sensor/metronome device (CPREzy), an accelerometer device (Phillips Q-CPR) and simple metronome on the quality of chest compressions on a manikin by trained rescuers. The primary outcome was compression depth. Secondary outcomes were compression rate, proportion of chest compressions with inadequate depth, incomplete release and user satisfaction. The pressure sensor device improved compression depth (37.24-43.64 mm, p=0.02), the accelerometer device decreased chest compression depth (37.38-33.19 mm, p=0.04) whilst the metronome had no effect (39.88 mm vs. 40.64 mm, p=0.802). Compression rate fell with all devices (pressure sensor device 114.68-98.84 min(-1), p=0.001, accelerometer 112.04-102.92 min(-1), p=0.072 and metronome 108.24 min(-1) vs. 99.36 min(-1), p=0.009). The pressure sensor feedback device reduced the proportion of compressions with inadequate depth (0.52 vs. 0.24, p=0.013) whilst the accelerometer device and metronome did not have a statistically significant effect. Incomplete release of compressions was common, but unaffected by the CPR feedback devices. Users preferred the accelerometer and metronome devices over the pressure sensor device. A post hoc study showed that de-activating the voice prompt on the accelerometer device prevented the deterioration in compression quality seen in the main study. CPR feedback devices vary in their ability to improve performance. In this study the pressure sensor device improved compression depth, whilst the accelerometer device reduced it and metronome had no effect. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Komasawa, Nobuyasu; Ueki, Ryusuke; Kaminoh, Yoshiroh; Nishi, Shin-Ichi
2014-10-01
In the 2010 American Heart Association guidelines, supraglottic devices (SGDs) such as the laryngeal mask are proposed as alternatives to tracheal intubation for cardiopulmonary resuscitation. Some SGDs can also serve as a means for tracheal intubation after successful ventilation. The purpose of this study was to evaluate the effect of chest compression on airway management with four intubating SGDs, aura-i (aura-i), air-Q (air-Q), i-gel (i-gel), and Fastrack (Fastrack), during cardiopulmonary resuscitation using a manikin. Twenty novice physicians inserted the four intubating SGDs into a manikin with or without chest compression. Insertion time and successful ventilation rate were measured. For cases of successful ventilation, blind tracheal intubation via the intubating SGD was performed with chest compression and success or failure within 30 s was recorded. Chest compression did not decrease the ventilation success rate of the four intubating SGDs (without chest compression (success/total): air-Q, 19/20; aura-i, 19/20; i-gel, 18/20; Fastrack, 19/20; with chest compression: air-Q, 19/20; aura-i, 19/20; i-gel, 16/20; Fastrack, 18/20). Insertion time was significantly lengthened by chest compression in the i-gel trial (P < 0.05), but not with the other three devices. The blind intubation success rate with chest compression was the highest in the air-Q trial (air-Q, 15/19; aura-i, 14/19; i-gel, 12/16; Fastrack, 10/18). This simulation study revealed the utility of intubating SGDs for airway management during chest compression.
Schober, P; Krage, R; Lagerburg, V; Van Groeningen, D; Loer, S A; Schwarte, L A
2014-04-01
Current cardiopulmonary resuscitation (CPR)-guidelines recommend an increased chest compression depth and rate compared to previous guidelines, and the use of automatic feedback devices is encouraged. However, it is unclear whether this compression depth can be maintained at an increased frequency. Moreover, the underlying surface may influence accuracy of feedback devices. We investigated compression depths over time and evaluated the accuracy of a feedback device on different surfaces. Twenty-four volunteers performed four two-minute blocks of CPR targeting at current guideline recommendations on different surfaces (floor, mattress, 2 backboards) on a patient simulator. Participants rested for 2 minutes between blocks. Influences of time and different surfaces on chest compression depth (ANOVA, mean [95% CI]) and accuracy of a feedback device to determine compression depth (Bland-Altman) were assessed. Mean compression depth did not reach recommended depth and decreased over time during all blocks (first block: from 42 mm [39-46 mm] to 39 mm [37-42 mm]). A two-minute resting period was insufficient to restore compression depth to baseline. No differences in compression depth were observed on different surfaces. The feedback device slightly underestimated compression depth on the floor (bias -3.9 mm), but markedly overestimated on the mattress (bias +12.6 mm). This overestimation was eliminated after correcting compression depth by a second sensor between manikin and mattress. Strategies are needed to improve chest compression depth, and more than two providers should alternate with chest compressions. The underlying surface does not necessarily adversely affect CPR performance but influences accuracy of feedback devices. Accuracy is improved by a second, posterior, sensor.
Buléon, Clément; Delaunay, Julie; Parienti, Jean-Jacques; Halbout, Laurent; Arrot, Xavier; Gérard, Jean-Louis; Hanouz, Jean-Luc
2016-09-01
Chest compressions require physical effort leading to increased fatigue and rapid degradation in the quality of cardiopulmonary resuscitation overtime. Despite harmful effect of interrupting chest compressions, current guidelines recommend that rescuers switch every 2 minutes. The impact on the quality of chest compressions during extended cardiopulmonary resuscitation has yet to be assessed. We conducted randomized crossover study on manikin (ResusciAnne; Laerdal). After randomization, 60 professional emergency rescuers performed 2 × 10 minutes of continuous chest compressions with and without a feedback device (CPRmeter). Efficient compression rate (primary outcome) was defined as the frequency target reached along with depth and leaning at the same time (recorded continuously). The 10-minute mean efficient compression rate was significantly better in the feedback group: 42% vs 21% (P< .001). There was no significant difference between the first (43%) and the tenth minute (36%; P= .068) with feedback. Conversely, a significant difference was evident from the second minute without feedback (35% initially vs 27%; P< .001). The efficient compression rate difference with and without feedback was significant every minute, from the second minute onwards. CPRmeter feedback significantly improved chest compression depth from the first minute, leaning from the second minute and rate from the third minute. A real-time feedback device delivers longer effective, steadier chest compressions over time. An extrapolation of these results from simulation may allow rescuer switches to be carried out beyond the currently recommended 2 minutes when a feedback device is used. Copyright © 2016 Elsevier Inc. All rights reserved.
Blomberg, Hans; Gedeborg, Rolf; Berglund, Lars; Karlsten, Rolf; Johansson, Jakob
2011-10-01
Mechanical chest compression devices are being implemented as an aid in cardiopulmonary resuscitation (CPR), despite lack of evidence of improved outcome. This manikin study evaluates the CPR-performance of ambulance crews, who had a mechanical chest compression device implemented in their routine clinical practice 8 months previously. The objectives were to evaluate time to first defibrillation, no-flow time, and estimate the quality of compressions. The performance of 21 ambulance crews (ambulance nurse and emergency medical technician) with the authorization to perform advanced life support was studied in an experimental, randomized cross-over study in a manikin setup. Each crew performed two identical CPR scenarios, with and without the aid of the mechanical compression device LUCAS. A computerized manikin was used for data sampling. There were no substantial differences in time to first defibrillation or no-flow time until first defibrillation. However, the fraction of adequate compressions in relation to total compressions was remarkably low in LUCAS-CPR (58%) compared to manual CPR (88%) (95% confidence interval for the difference: 13-50%). Only 12 out of the 21 ambulance crews (57%) applied the mandatory stabilization strap on the LUCAS device. The use of a mechanical compression aid was not associated with substantial differences in time to first defibrillation or no-flow time in the early phase of CPR. However, constant but poor chest compressions due to failure in recognizing and correcting a malposition of the device may counteract a potential benefit of mechanical chest compressions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Kim, Yeomyung
2017-01-01
Objective We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Methods Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. Results The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). Conclusion The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress. PMID:28854262
Yu, Byung Gyu; Oh, Je Hyeok; Kim, Yeomyung; Kim, Tae Wook
2017-01-01
We developed a new chest compression depth (CCD) measuring technology using radar and impulse-radio ultra-wideband (IR-UWB) sensor. This study was performed to determine its accuracy on a soft surface. Four trials, trial 1: chest compressions on the floor using an accelerometer device; trial 2: chest compressions on the floor using an IR-UWB sensor; trial 3: chest compressions on a foam mattress using an accelerometer device; trial 4: chest compressions on a foam mattress using an IR-UWB sensor, were performed in a random order. In all the trials, a cardiopulmonary resuscitation provider delivered 50 uninterrupted chest compressions to a manikin. The CCD measured by the manikin and the device were as follows: 57.42 ± 2.23 and 53.92 ± 2.92 mm, respectively in trial 1 (p < 0.001); 56.29 ± 1.96 and 54.16 ± 3.90 mm, respectively in trial 2 (p < 0.001); 55.61 ± 1.57 and 103.48 ± 10.48 mm, respectively in trial 3 (p < 0.001); 57.14 ± 3.99 and 55.51 ± 3.39 mm, respectively in trial 4 (p = 0.012). The gaps between the CCD measured by the manikin and the devices (accelerometer device vs. IR-UWB sensor) on the floor were not different (3.50 ± 2.08 mm vs. 3.15 ± 2.27 mm, respectively, p = 0.136). However, the gaps were significantly different on the foam mattress (48.53 ± 5.65 mm vs. 4.10 ± 2.47 mm, p < 0.001). The IR-UWB sensor could measure the CCD accurately both on the floor and on the foam mattress.
Device Assists Cardiac Chest Compression
NASA Technical Reports Server (NTRS)
Eichstadt, Frank T.
1995-01-01
Portable device facilitates effective and prolonged cardiac resuscitation by chest compression. Developed originally for use in absence of gravitation, also useful in terrestrial environments and situations (confined spaces, water rescue, medical transport) not conducive to standard manual cardiopulmonary resuscitation (CPR) techniques.
Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest.
Eichhorn, S; Mendoza, A; Prinzing, A; Stroh, A; Xinghai, L; Polski, M; Heller, M; Lahm, H; Wolf, E; Lange, R; Krane, M
2017-01-01
According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR) with an established system (LUCAS II) in a pig model. Methods . Pigs ( n = 5/group) in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO 2 , regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results . Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion . Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device.
Corpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest
Mendoza, A.; Prinzing, A.; Stroh, A.; Xinghai, L.; Polski, M.; Heller, M.; Lahm, H.; Wolf, E.; Lange, R.; Krane, M.
2017-01-01
According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR) with an established system (LUCAS II) in a pig model. Methods. Pigs (n = 5/group) in provoked ventricular fibrillation were left untreated for 5 minutes, after which 15 min of cardiopulmonary resuscitation was performed with chest compressions. After 15 min, defibrillation was performed every 2 min if necessary, and up to 3 doses of adrenaline were given. If there was no return of spontaneous circulation after 25 min, the experiment was terminated. Coronary perfusion pressure, carotid blood flow, end-expiratory CO2, regional oxygen saturation by near infrared spectroscopy, blood gas, and local organ perfusion with fluorescent labelled microspheres were measured at baseline and during resuscitation. Results. Animals treated with Corpuls CPR had significantly higher mean arterial pressures during resuscitation, along with a detectable trend of greater carotid blood flow and organ perfusion. Conclusion. Chest compressions with the Corpuls CPR device generated significantly higher mean arterial pressures than compressions performed with the LUCAS II device. PMID:29392137
Mechanical versus manual chest compressions for cardiac arrest.
Brooks, Steven C; Hassan, Nizar; Bigham, Blair L; Morrison, Laurie J
2014-02-27
This is the first update of the Cochrane review on mechanical chest compression devices published in 2011 (Brooks 2011). Mechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR). To assess the effectiveness of mechanical chest compressions versus standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest. We searched the Cochrane Central Register of Controlled Studies (CENTRAL; 2013, Issue 12), MEDLINE Ovid (1946 to 2013 January Week 1), EMBASE (1980 to 2013 January Week 2), Science Citation abstracts (1960 to 18 November 2009), Science Citation Index-Expanded (SCI-EXPANDED) (1970 to 11 January 2013) on Thomson Reuters Web of Science, biotechnology and bioengineering abstracts (1982 to 18 November 2009), conference proceedings Citation Index-Science (CPCI-S) (1990 to 11 January 2013) and clinicaltrials.gov (2 August 2013). We applied no language restrictions. Experts in the field of mechanical chest compression devices and manufacturers were contacted. We included randomised controlled trials (RCTs), cluster RCTs and quasi-randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with atraumatic cardiac arrest. Two review authors abstracted data independently; disagreement between review authors was resolved by consensus and by a third review author if consensus could not be reached. The methodologies of selected studies were evaluated by a single author for risk of bias. The primary outcome was survival to hospital discharge with good neurological outcome. We planned to use RevMan 5 (Version 5.2. The Nordic Cochrane Centre) and the DerSimonian & Laird method (random-effects model) to provide a pooled estimate for risk ratio (RR) with 95% confidence intervals (95% CIs), if data allowed. Two new studies were included in this update. Six trials in total, including data from 1166 participants, were included in the review. The overall quality of included studies was poor, and significant clinical heterogeneity was observed. Only one study (N = 767) reported survival to hospital discharge with good neurological function (defined as a Cerebral Performance Category score of one or two), demonstrating reduced survival with mechanical chest compressions when compared with manual chest compressions (RR 0.41, 95% CI 0.21 to 0.79). Data from four studies demonstrated increased return of spontaneous circulation, and data from two studies demonstrated increased survival to hospital admission with mechanical chest compressions as compared with manual chest compressions, but none of the individual estimates reached statistical significance. Marked clinical heterogeneity between studies precluded any pooled estimates of effect. Evidence from RCTs in humans is insufficient to conclude that mechanical chest compressions during cardiopulmonary resuscitation for cardiac arrest are associated with benefit or harm. Widespread use of mechanical devices for chest compressions during cardiac events is not supported by this review. More RCTs that measure and account for the CPR process in both arms are needed to clarify the potential benefit to be derived from this intervention.
Austin, Andrea L; Spalding, Carmen N; Landa, Katrina N; Myer, Brian R; Donald, Cure; Smith, Jason E; Platt, Gerald; King, Heather C
2017-10-27
In effort to improve chest compression quality among health care providers, numerous feedback devices have been developed. Few studies, however, have focused on the use of cardiopulmonary resuscitation feedback devices for infants and children. This study evaluated the quality of chest compressions with standard team-leader coaching, a metronome (MetroTimer by ONYX Apps), and visual feedback (SkillGuide Cardiopulmonary Feedback Device) during simulated infant cardiopulmonary resuscitation. Seventy voluntary health care providers who had recently completed Pediatric Advanced Life Support or Basic Life Support courses were randomized to perform simulated infant cardiopulmonary resuscitation into 1 of 3 groups: team-leader coaching alone (control), coaching plus metronome, or coaching plus SkillGuide for 2 minutes continuously. Rate, depth, and frequency of complete recoil during cardiopulmonary resuscitation were recorded by the Laerdal SimPad device for each participant. American Heart Association-approved compression techniques were randomized to either 2-finger or encircling thumbs. The metronome was associated with more ideal compression rate than visual feedback or coaching alone (104/min vs 112/min and 113/min; P = 0.003, 0.019). Visual feedback was associated with more ideal depth than auditory (41 mm vs 38.9; P = 0.03). There were no significant differences in complete recoil between groups. Secondary outcomes of compression technique revealed a difference of 1 mm. Subgroup analysis of male versus female showed no difference in mean number of compressions (221.76 vs 219.79; P = 0.72), mean compression depth (40.47 vs 39.25; P = 0.09), or rate of complete release (70.27% vs 64.96%; P = 0.54). In the adult literature, feedback devices often show an increase in quality of chest compressions. Although more studies are needed, this study did not demonstrate a clinically significant improvement in chest compressions with the addition of a metronome or visual feedback device, no clinically significant difference in Pediatric Advanced Life Support-approved compression technique, and no difference between compression quality between genders.
[Real-time feedback systems for improvement of resuscitation quality].
Lukas, R P; Van Aken, H; Engel, P; Bohn, A
2011-07-01
The quality of chest compression is a determinant of survival after cardiac arrest. Therefore, the European Resuscitation Council (ERC) 2010 guidelines on resuscitation strongly focus on compression quality. Despite its impact on survival, observational studies have shown that chest compression quality is not reached by professional rescue teams. Real-time feedback devices for resuscitation are able to measure chest compression during an ongoing resuscitation attempt through a sternal sensor equipped with a motion and pressure detection system. In addition to the electrocardiograph (ECG) ventilation can be detected by transthoracic impedance monitoring. In cases of quality deviation, such as shallow chest compression depth or hyperventilation, feedback systems produce visual or acoustic alarms. Rescuers can thereby be supported and guided to the requested quality in chest compression and ventilation. Feedback technology is currently available both as a so-called stand-alone device and as an integrated feature in a monitor/defibrillator unit. Multiple studies have demonstrated sustainable enhancement in the education of resuscitation due to the use of real-time feedback technology. There is evidence that real-time feedback for resuscitation combined with training and debriefing strategies can improve both resuscitation quality and patient survival. Chest compression quality is an independent predictor for survival in resuscitation and should therefore be measured and documented in further clinical multicenter trials.
Navarro-Patón, R; Freire-Tellado, M; Basanta-Camiño, S; Barcala-Furelos, R; Arufe-Giraldez, V; Rodriguez-Fernández, J E
2018-05-01
To evaluate the learning of basic life support (BLS) measures on the part of laypersons after 3different teaching programs. A quasi-experimental before-after study involving a non-probabilistic sample without a control group was carried out. Primary school teacher students from the University of Santiago (Spain). A total of 124 students (68.8% women and 31.2% men) aged 20-39 years (M=22.23; SD=3.79), with no previous knowledge of BLS, were studied. Three teaching programs were used: a traditional course, an audio-visual approach and feedback devices. Chest compressions as sole cardiopulmonary resuscitation skill evaluation: average compression depth, compression rate, chest recoil percentage and percentage of correct compressions. Automated external defibrillator: time needed to apply a shock before and after the course. There were significant differences in the results obtained after 2minutes of chest compressions, depending on the training program received, with feedback devices having a clear advantage referred to average compression depth (p<0.001), compression rate (p<0.001), chest recoil percentage (p<0.001) and percentage of correct compressions (p<0.001). Regarding automated external defibrillator, statistically significant differences were found in T after (p=0.025). The teaching course using feedback devices obtained the best results in terms of the quality of chest compressions, followed by the traditional course and audio-visual approach. These favorable results were present in both men and women. All 3teaching methods reached the goal of reducing defibrillation time. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.
Fernández, Sarah N.; González, Rafael; Solana, María J.; Urbano, Javier; Toledo, Blanca
2017-01-01
Aims Chest compressions (CC) during cardiopulmonary resuscitation are not sufficiently effective in many circumstances. Mechanical CC could be more effective than manual CC, but there are no studies comparing both techniques in children. The objective of this study was to compare the effectiveness of manual and mechanical chest compressions with Thumper device in a pediatric cardiac arrest animal model. Material and methods An experimental model of asphyxial cardiac arrest (CA) in 50 piglets (mean weight 9.6 kg) was used. Animals were randomized to receive either manual CC or mechanical CC using a pediatric piston chest compressions device (Life-Stat®, Michigan Instruments). Mean arterial pressure (MAP), arterial blood gases and end-tidal CO2 (etCO2) values were measured at 3, 9, 18 and 24 minutes after the beginning of resuscitation. Results There were no significant differences in MAP, DAP, arterial blood gases and etCO2 between chest compression techniques during CPR. Survival rate was higher in the manual CC (15 of 30 = 50%) than in the mechanical CC group (3 of 20 = 15%) p = 0.016. In the mechanical CC group there was a non significant higher incidence of haemorrhage through the endotracheal tube (45% vs 20%, p = 0.114). Conclusions In a pediatric animal model of cardiac arrest, mechanical piston chest compressions produced lower survival rates than manual chest compressions, without any differences in hemodynamic and respiratory parameters. PMID:29190801
A randomized control hands-on defibrillation study-Barrier use evaluation.
Wampler, David; Kharod, Chetan; Bolleter, Scotty; Burkett, Alison; Gabehart, Caitlin; Manifold, Craig
2016-06-01
Chest compressions and defibrillation are the only therapies proven to increase survival in cardiac arrest. Historically, rescuers must remove hands to shock, thereby interrupting chest compressions. This hands-off time results in a zero blood flow state. Pauses have been associated with poorer neurological recovery. This was a blinded randomized control cadaver study evaluating the detection of defibrillation during manual chest compressions. An active defibrillator was connected to the cadaver in the sternum-apex configuration. The sham defibrillator was not connected to the cadaver. Subjects performed chest compressions using 6 barrier types: barehand, single and double layer nitrile gloves, firefighter gloves, neoprene pad, and a manual chest compression/decompression device. Randomized defibrillations (10 per barrier type) were delivered at 30 joules (J) for bare hand and 360J for all other barriers. After each shock, the subject indicated degree of sensation on a VAS scale. Ten subjects participated. All subjects detected 30j shocks during barehand compressions, with only 1 undetected real shock. All barriers combined totaled 500 shocks delivered. Five (1%) active shocks were detected, 1(0.2%) single layer of Nitrile, 3(0.6%) with double layer nitrile, and 1(0.2%) with the neoprene barrier. One sham shock was reported with the single layer nitrile glove. No shocks were detected with fire gloves or compression decompression device. All shocks detected barely perceptible (0.25(±0.05)cm on 10cm VAS scale). Nitrile gloves and neoprene pad prevent (99%) responder's detection of defibrillation of a cadaver. Fire gloves and compression decompression device prevented detection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Gittinger, Matthew; Brolliar, Sarah M; Grand, James A; Nichol, Graham; Fernandez, Rosemarie
2017-06-01
This pilot study used a simulation-based platform to evaluate the effect of an automated mechanical chest compression device on team communication and patient management. Four-member emergency department interprofessional teams were randomly assigned to perform manual chest compressions (control, n = 6) or automated chest compressions (intervention, n = 6) during a simulated cardiac arrest with 2 phases: phase 1 baseline (ventricular tachycardia), followed by phase 2 (ventricular fibrillation). Patient management was coded using an Advanced Cardiovascular Life Support-based checklist. Team communication was categorized in the following 4 areas: (1) teamwork focus; (2) huddle events, defined as statements focused on re-establishing situation awareness, reinforcing existing plans, and assessing the need to adjust the plan; (3) clinical focus; and (4) profession of team member. Statements were aggregated for each team. At baseline, groups were similar with respect to total communication statements and patient management. During cardiac arrest, the total number of communication statements was greater in teams performing manual compressions (median, 152.3; interquartile range [IQR], 127.6-181.0) as compared with teams using an automated compression device (median, 105; IQR, 99.5-123.9). Huddle events were more frequent in teams performing automated chest compressions (median, 4.0; IQR, 3.1-4.3 vs. 2.0; IQR, 1.4-2.6). Teams randomized to the automated compression intervention had a delay to initial defibrillation (median, 208.3 seconds; IQR, 153.3-222.1 seconds) as compared with control teams (median, 63.2 seconds; IQR, 30.1-397.2 seconds). Use of an automated compression device may impact both team communication and patient management. Simulation-based assessments offer important insights into the effect of technology on healthcare teams.
Gutiérrez, J. J.; Russell, James K.
2016-01-01
Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated resuscitation scenario. Materials and Methods. Compressions were provided to a manikin on two mattresses, foam and sprung, with and without a backboard. One accelerometer was placed on the chest and the second at the manikin's back. Chest displacement and mattress displacement were calculated from the spectral analysis of the corresponding acceleration every 2 seconds and subtracted to compute the actual sternal-spinal displacement. Compression rate was obtained from the chest acceleration. Results. Median unsigned error in depth was 2.1 mm (4.4%). Error was 2.4 mm in the foam and 1.7 mm in the sprung mattress (p < 0.001). Error was 3.1/2.0 mm and 1.8/1.6 mm with/without backboard for foam and sprung, respectively (p < 0.001). Median error in rate was 0.9 cpm (1.0%), with no significant differences between test conditions. Conclusion. The system provided accurate feedback on chest compression depth and rate on soft surfaces. Our solution compensated mattress displacement, avoiding overestimation of compression depth when CPR is performed on soft surfaces. PMID:27999808
Minami, Kouichiro; Kokubo, Yota; Maeda, Ichinosuke; Hibino, Shingo
2017-02-01
In chest compression for cardiopulmonary resuscitation (CPR), the lower half of the sternum is pressed according to the American Heart Association (AHA) guidelines 2010. These have been no studies which identify the exact location of the applied by individual chest compressions. We developed a rubber power-flexible capacitive sensor that could measure the actual pressure point of chest compression in real time. Here, we examined the pressure point of chest compression by ambulance crews during CPR using a mannequin. We included 179 ambulance crews. Chest compression was performed for 2 min. The pressure position was monitored, and the quality of chest compression was analyzed by using a flexible pressure sensor (Shinnosukekun™). Of the ambulance crews, 58 (32.4 %) pressed the center and 121 (67.6 %) pressed outside the proper area of chest compression. Many of them pressed outside the center; 8, 7, 41, and 90 pressed on the caudal, left, right, and cranial side, respectively. Average compression rate, average recoil, average depth, and average duty cycle were 108.6 counts per minute, 0.089, 4.5 cm, and 48.27 %, respectively. Many of the ambulance crews did not press on the sternal lower half definitely. This new device has the potential to improve the quality of CPR during training or in clinical practice.
Ruiz de Gauna, Sofía; González-Otero, Digna M.; Ruiz, Jesus; Russell, James K.
2016-01-01
Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth. Materials and Methods We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer’s hands and the manikin’s chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor. Results The median (IQR) percent error was 5.9% (2.8–10.3), 6.3% (2.9–11.3), and 2.5% (1.2–4.4) for depth and 1.7% (0.0–2.3), 0.0% (0.0–2.0), and 0.9% (0.4–1.6) for rate, respectively. Depth accuracy depended on the target rate (p < 0.001) and on the rescuer couple (p < 0.001) within each method. Conclusions Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data. PMID:26930061
Chest compression rates and survival following out-of-hospital cardiac arrest.
Idris, Ahamed H; Guffey, Danielle; Pepe, Paul E; Brown, Siobhan P; Brooks, Steven C; Callaway, Clifton W; Christenson, Jim; Davis, Daniel P; Daya, Mohamud R; Gray, Randal; Kudenchuk, Peter J; Larsen, Jonathan; Lin, Steve; Menegazzi, James J; Sheehan, Kellie; Sopko, George; Stiell, Ian; Nichol, Graham; Aufderheide, Tom P
2015-04-01
Guidelines for cardiopulmonary resuscitation recommend a chest compression rate of at least 100 compressions/min. A recent clinical study reported optimal return of spontaneous circulation with rates between 100 and 120/min during cardiopulmonary resuscitation for out-of-hospital cardiac arrest. However, the relationship between compression rate and survival is still undetermined. Prospective, observational study. Data is from the Resuscitation Outcomes Consortium Prehospital Resuscitation IMpedance threshold device and Early versus Delayed analysis clinical trial. Adults with out-of-hospital cardiac arrest treated by emergency medical service providers. None. Data were abstracted from monitor-defibrillator recordings for the first five minutes of emergency medical service cardiopulmonary resuscitation. Multiple logistic regression assessed odds ratio for survival by compression rate categories (<80, 80-99, 100-119, 120-139, ≥140), both unadjusted and adjusted for sex, age, witnessed status, attempted bystander cardiopulmonary resuscitation, location of arrest, chest compression fraction and depth, first rhythm, and study site. Compression rate data were available for 10,371 patients; 6,399 also had chest compression fraction and depth data. Age (mean±SD) was 67±16 years. Chest compression rate was 111±19 per minute, compression fraction was 0.70±0.17, and compression depth was 42±12 mm. Circulation was restored in 34%; 9% survived to hospital discharge. After adjustment for covariates without chest compression depth and fraction (n=10,371), a global test found no significant relationship between compression rate and survival (p=0.19). However, after adjustment for covariates including chest compression depth and fraction (n=6,399), the global test found a significant relationship between compression rate and survival (p=0.02), with the reference group (100-119 compressions/min) having the greatest likelihood for survival. After adjustment for chest compression fraction and depth, compression rates between 100 and 120 per minute were associated with greatest survival to hospital discharge.
Gates, Simon; Lall, Ranjit; Quinn, Tom; Deakin, Charles D; Cooke, Matthew W; Horton, Jessica; Lamb, Sarah E; Slowther, Anne-Marie; Woollard, Malcolm; Carson, Andy; Smyth, Mike; Wilson, Kate; Parcell, Garry; Rosser, Andrew; Whitfield, Richard; Williams, Amanda; Jones, Rebecca; Pocock, Helen; Brock, Nicola; Black, John Jm; Wright, John; Han, Kyee; Shaw, Gary; Blair, Laura; Marti, Joachim; Hulme, Claire; McCabe, Christopher; Nikolova, Silviya; Ferreira, Zenia; Perkins, Gavin D
2017-03-01
Mechanical chest compression devices may help to maintain high-quality cardiopulmonary resuscitation (CPR), but little evidence exists for their effectiveness. We evaluated whether or not the introduction of Lund University Cardiopulmonary Assistance System-2 (LUCAS-2; Jolife AB, Lund, Sweden) mechanical CPR into front-line emergency response vehicles would improve survival from out-of-hospital cardiac arrest (OHCA). Evaluation of the LUCAS-2 device as a routine ambulance service treatment for OHCA. Pragmatic, cluster randomised trial including adults with non-traumatic OHCA. Ambulance dispatch staff and those collecting the primary outcome were blind to treatment allocation. Blinding of the ambulance staff who delivered the interventions and reported initial response to treatment was not possible. We also conducted a health economic evaluation and a systematic review of all trials of out-of-hospital mechanical chest compression. Four UK ambulance services (West Midlands, North East England, Wales and South Central), comprising 91 urban and semiurban ambulance stations. Clusters were ambulance service vehicles, which were randomly assigned (approximately 1 : 2) to the LUCAS-2 device or manual CPR. Patients were included if they were in cardiac arrest in the out-of-hospital environment. Exclusions were patients with cardiac arrest as a result of trauma, with known or clinically apparent pregnancy, or aged < 18 years. Patients received LUCAS-2 mechanical chest compression or manual chest compressions according to the first trial vehicle to arrive on scene. Survival at 30 days following cardiac arrest; survival without significant neurological impairment [Cerebral Performance Category (CPC) score of 1 or 2]. We enrolled 4471 eligible patients (1652 assigned to the LUCAS-2 device and 2819 assigned to control) between 15 April 2010 and 10 June 2013. A total of 985 (60%) patients in the LUCAS-2 group received mechanical chest compression and 11 (< 1%) patients in the control group received LUCAS-2. In the intention-to-treat analysis, 30-day survival was similar in the LUCAS-2 (104/1652, 6.3%) and manual CPR groups [193/2819, 6.8%; adjusted odds ratio (OR) 0.86, 95% confidence interval (CI) 0.64 to 1.15]. Survival with a CPC score of 1 or 2 may have been worse in the LUCAS-2 group (adjusted OR 0.72, 95% CI 0.52 to 0.99). No serious adverse events were noted. The systematic review found no evidence of a survival advantage if mechanical chest compression was used. The health economic analysis showed that LUCAS-2 was dominated by manual chest compression. There was substantial non-compliance in the LUCAS-2 arm. For 272 out of 1652 patients (16.5%), mechanical chest compression was not used for reasons that would not occur in clinical practice. We addressed this issue by using complier average causal effect analyses. We attempted to measure CPR quality during the resuscitation attempts of trial participants, but were unable to do so. There was no evidence of improvement in 30-day survival with LUCAS-2 compared with manual compressions. Our systematic review of recent randomised trials did not suggest that survival or survival without significant disability may be improved by the use of mechanical chest compression. The use of mechanical chest compression for in-hospital cardiac arrest, and in specific circumstances (e.g. transport), has not yet been evaluated. Current Controlled Trials ISRCTN08233942. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 21, No. 11. See the NIHR Journals Library website for further project information.
Komasawa, Nobuyasu; Fujiwara, Shunsuke; Majima, Nozomi; Minami, Toshiaki
2015-08-01
Pregnancy-related mortality, estimated to occur in approximately 1: 50,000 deliveries, is rare in developed countries. The 2010 American Heart Association (AHA) Guidelines for Resuscitation emphasize the importance of high-quality chest compression as a key determinant of successful cardiopulmonary resuscitation. During pregnancy, the uterus can compress the inferior vena cava, impeding venous return and thereby reducing stroke volume and cardiac output. To maximize the effectiveness of chest compressions in pregnancy, the AHA guidelines recommend the 27-30 degrees left-lateral tilt (LLT) position. When CPR is performed on parturients in the LLT position, chest compressions will probably be more effective if performed with the operator standing on the left side of the patient. The videolaryngoscope Pentax-AWS Airwayscope (AWS) was found to be an effective tool for airway management during chest compressions in 27 LLT simulations, suggesting that the AWS may be a useful device for airway management during maternal resuscitation.
[Automatic mechanical chest compression during helicopter transportation].
Kyrval, Helle S; Ahmad, Khalil
2010-11-15
We describe a case story with a drowned, hypothermic trauma patient treated with an automatic mechanical chest compression device during helicopter transportation to a trauma center. After falling from a 25 meter high bridge into 2 °C water, she was rescued lifeless 17 minutes later. Advanced life support was initiated. During transport by a rescue helicopter, chest compressions were effectively provided by Lund University Cardiopulmonary Assist System (LUCAS). Upon arrival to a trauma centre approx. 60 minutes later, the patient was treated with extracorporal circulation and rewarmed. She was eventually discharged to her home with minor loss of cerebral function.
Parnia, Sam; Nasir, Asad; Ahn, Anna; Malik, Hanan; Yang, Jie; Zhu, Jiawen; Dorazi, Francis; Richman, Paul
2014-04-01
A major hurdle limiting the ability to improve the quality of resuscitation has been the lack of a noninvasive real-time detection system capable of monitoring the quality of cerebral and other organ perfusion, as well as oxygen delivery during cardiopulmonary resuscitation. Here, we report on a novel system of cerebral perfusion targeted resuscitation. An observational study evaluating the role of cerebral oximetry (Equanox; Nonin, Plymouth, MI, and Invos; Covidien, Mansfield, MA) as a real-time marker of cerebral perfusion and oxygen delivery together with the impact of an automated mechanical chest compression system (Life Stat; Michigan Instruments, Grand Rapids, MI) on oxygen delivery and return of spontaneous circulation following in-hospital cardiac arrest. Tertiary medical center. In-hospital cardiac arrest patients (n = 34). Cerebral oximetry provided real-time information regarding the quality of perfusion and oxygen delivery. The use of automated mechanical chest compression device (n = 12) was associated with higher regional cerebral oxygen saturation compared with manual chest compression device (n = 22) (53.1% ± 23.4% vs 24% ± 25%, p = 0.002). There was a significant difference in mean regional cerebral oxygen saturation (median % ± interquartile range) in patients who achieved return of spontaneous circulation (n = 15) compared with those without return of spontaneous circulation (n = 19) (47.4% ± 21.4% vs 23% ± 18.42%, p < 0.001). After controlling for patients achieving return of spontaneous circulation or not, significantly higher mean regional cerebral oxygen saturation levels during cardiopulmonary resuscitation were observed in patients who were resuscitated using automated mechanical chest compression device (p < 0.001). The integration of cerebral oximetry into cardiac arrest resuscitation provides a novel noninvasive method to determine the quality of cerebral perfusion and oxygen delivery to the brain. The use of automated mechanical chest compression device during in-hospital cardiac arrest may lead to improved oxygen delivery and organ perfusion.
Udassi, Jai P.; Udassi, Sharda; Lamb, Melissa A.; Lamb, Kenneth E.; Theriaque, Douglas W.; Shuster, Jonathan J.; Zaritsky, Arno L.; Haque, Ikram U.
2013-01-01
Objective We developed an adhesive glove device (AGD) to perform ACD-CPR in pediatric manikins, hypothesizing that AGD-ACD-CPR provides better chest decompression compared to standard (S)-CPR. Design Split-plot design randomizing 16 subjects to test four manikin-technique models in a crossover fashion to AGD-ACD-CPR vs. S-CPR. Healthcare providers performed 5 min of CPR with 30:2 compression:ventilation ratio in the four manikin models: (1) adolescent; (2) child two-hand; (3) child one-hand; and (4) infant two-thumb. Methods Modified manikins recorded compression pressure (CP), compression depth (CD) and decompression depth (DD). The AGD consisted of a modified oven mitt with an adjustable strap; a Velcro patch was sewn to the palmer aspect. The counter Velcro patch was bonded to the anterior chest wall. For infant CPR, the thumbs of two oven mitts were stitched together with Velcro. Subjects were asked to actively pull up during decompression. Subjects’ heart rate (HR), respiratory rate (RR) and recovery time (RT) for HR/RR to return to baseline were recorded. Subjects were blinded to data recordings. Data (mean ± SEM) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as P ≤ 0.05. Results Mean decompression depth difference was significantly greater with AGD-ACD-CPR compared to S-CPR; 38–75% of subjects achieved chest decompression to or beyond baseline. AGD-ACD-CPR provided 6–12% fewer chest compressions/minute than S-CPR group. There was no significant difference in CD, CP, HR, RR and RT within each group comparing both techniques. Conclusion A simple, inexpensive glove device for ACD-CPR improved chest decompression with emphasis on active pull in manikins without excessive rescuer fatigue. The clinical implication of fewer compressions/minute in the AGD group needs to be evaluated. PMID:19683849
Tang, Lu; Gu, Wan-Jie; Wang, Fei
2015-01-01
Recent evidence regarding mechanical chest compressions in out-of-hospital cardiac arrest (OHCA) is conflicting. The objective of this study was to perform a meta-analysis of randomized controlled trials (RCTs) to compare the effect of mechanical versus manual chest compressions on resuscitation outcomes in OHCA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, and the ClinicalTrials.gov registry were searched. In total, five RCTs with 12,510 participants were included. Compared with manual chest compressions, mechanical chest compressions did not significantly improve survival with good neurological outcome to hospital discharge (relative risks (RR) 0.80, 95% CI 0.61–1.04, P = 0.10; I2 = 65%), return of spontaneous circulation (RR 1.02, 95% CI 0.95–1.09, P = 0.59; I2 = 0%), or long-term (≥6 months) survival (RR 0.96, 95% CI 0.79–1.16, P = 0.65; I2 = 16%). In addition, mechanical chest compressions were associated with worse survival to hospital admission (RR 0.94, 95% CI 0.89–1.00, P = 0.04; I2 = 0%) and to hospital discharge (RR 0.88, 95% CI 0.78–0.99, P = 0.03; I2 = 0%). Based on the current evidence, widespread use of mechanical devices for chest compressions in OHCA cannot be recommended. PMID:26503429
Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki
2015-05-01
The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.
Mechanical CPR: Who? When? How?
Poole, Kurtis; Couper, Keith; Smyth, Michael A; Yeung, Joyce; Perkins, Gavin D
2018-05-29
In cardiac arrest, high quality cardiopulmonary resuscitation (CPR) is a key determinant of patient survival. However, delivery of effective chest compressions is often inconsistent, subject to fatigue and practically challenging.Mechanical CPR devices provide an automated way to deliver high-quality CPR. However, large randomised controlled trials of the routine use of mechanical devices in the out-of-hospital setting have found no evidence of improved patient outcome in patients treated with mechanical CPR, compared with manual CPR. The limited data on use during in-hospital cardiac arrest provides preliminary data supporting use of mechanical devices, but this needs to be robustly tested in randomised controlled trials.In situations where high-quality manual chest compressions cannot be safely delivered, the use of a mechanical device may be a reasonable clinical approach. Examples of such situations include ambulance transportation, primary percutaneous coronary intervention, as a bridge to extracorporeal CPR and to facilitate uncontrolled organ donation after circulatory death.The precise time point during a cardiac arrest at which to deploy a mechanical device is uncertain, particularly in patients presenting in a shockable rhythm. The deployment process requires interruptions in chest compression, which may be harmful if the pause is prolonged. It is recommended that use of mechanical devices should occur only in systems where quality assurance mechanisms are in place to monitor and manage pauses associated with deployment.In summary, mechanical CPR devices may provide a useful adjunct to standard treatment in specific situations, but current evidence does not support their routine use.
Holmqvist, Kristian; Svensson, Mats Y; Davidsson, Johan; Gutsche, Andreas; Tomasch, Ernst; Darok, Mario; Ravnik, Dean
2016-02-01
The chest response of the human body has been studied for several load conditions, but is not well known in the case of steering wheel rim-to-chest impact in heavy goods vehicle frontal collisions. The aim of this study was to determine the response of the human chest in a set of simulated steering wheel impacts. PMHS tests were carried out and analysed. The steering wheel load pattern was represented by a rigid pendulum with a straight bar-shaped front. A crash test dummy chest calibration pendulum was utilised for comparison. In this study, a set of rigid bar impacts were directed at various heights of the chest, spanning approximately 120mm around the fourth intercostal space. The impact energy was set below a level estimated to cause rib fracture. The analysed results consist of responses, evaluated with respect to differences in the impacting shape and impact heights on compression and viscous criteria chest injury responses. The results showed that the bar impacts consistently produced lesser scaled chest compressions than the hub; the Middle bar responses were around 90% of the hub responses. A superior bar impact provided lesser chest compression; the average response was 86% of the Middle bar response. For inferior bar impacts, the chest compression response was 116% of the chest compression in the middle. The damping properties of the chest caused the compression to decrease in the high speed bar impacts to 88% of that in low speed impacts. From the analysis it could be concluded that the bar impact shape provides lower chest criteria responses compared to the hub. Further, the bar responses are dependent on the impact location of the chest. Inertial and viscous effects of the upper body affect the responses. The results can be used to assess the responses of human substitutes such as anthropomorphic test devices and finite element human body models, which will benefit the development process of heavy goods vehicle safety systems. Copyright © 2015 Elsevier Ltd. All rights reserved.
Havel, Christof; Schreiber, Wolfgang; Trimmel, Helmut; Malzer, Reinhard; Haugk, Moritz; Richling, Nina; Riedmüller, Eva; Sterz, Fritz; Herkner, Harald
2010-01-01
Automated verbal and visual feedback improves quality of resuscitation in out-of-hospital cardiac arrest and was proven to increase short-term survival. Quality of resuscitation may be hampered in more difficult situations like emergency transportation. Currently there is no evidence if feedback devices can improve resuscitation quality during different modes of transportation. To assess the effect of real time automated feedback on the quality of resuscitation in an emergency transportation setting. Randomised cross-over trial. Medical University of Vienna, Vienna Municipal Ambulance Service and Helicopter Emergency Medical Service Unit (Christophorus Flugrettungsverein) in September 2007. European Resuscitation Council (ERC) certified health care professionals performing CPR in a flying helicopter and in a moving ambulance vehicle on a manikin with human-like chest properties. CPR sessions, with real time automated feedback as the intervention and standard CPR without feedback as control. Quality of chest compression during resuscitation. Feedback resulted in less deviation from ideal compression rate 100 min(-1) (9+/-9 min(-1), p<0.0001) with this effect becoming steadily larger over time. Applied work was less in the feedback group compared to controls (373+/-448 cm x compression; p<0.001). Feedback did not influence ideal compression depth significantly. There was some indication of a learning effect of the feedback device. Real time automated feedback improves certain aspects of CPR quality in flying helicopters and moving ambulance vehicles. The effect of feedback guidance was most pronounced for chest compression rate. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
The Efficacy of LUCAS in Prehospital Cardiac Arrest Scenarios: A Crossover Mannequin Study.
Gyory, Robert A; Buchle, Scott E; Rodgers, David; Lubin, Jeffrey S
2017-04-01
High-quality cardiopulmonary resuscitation (CPR) is critical for successful cardiac arrest outcomes. Mechanical devices may improve CPR quality. We simulated a prehospital cardiac arrest, including patient transport, and compared the performance of the LUCAS™ device, a mechanical chest compression-decompression system, to manual CPR. We hypothesized that because of the movement involved in transporting the patient, LUCAS would provide chest compressions more consistent with high-quality CPR guidelines. We performed a crossover-controlled study in which a recording mannequin was placed on the second floor of a building. An emergency medical services (EMS) crew responded, defibrillated, and provided either manual or LUCAS CPR. The team transported the mannequin through hallways and down stairs to an ambulance and drove to the hospital with CPR in progress. Critical events were manually timed while the mannequin recorded data on compressions. Twenty-three EMS providers participated. Median time to defibrillation was not different for LUCAS compared to manual CPR (p=0.97). LUCAS had a lower median number of compressions per minute (112/min vs. 125/min; IQR = 102-128 and 102-126 respectively; p<0.002), which was more consistent with current American Heart Association CPR guidelines, and percent adequate compression rate (71% vs. 40%; IQR = 21-93 and 12-88 respectively; p<0.002). In addition, LUCAS had a higher percent adequate depth (52% vs. 36%; IQR = 25-64 and 29-39 respectively; p<0.007) and lower percent total hands-off time (15% vs. 20%; IQR = 10-22 and 15-27 respectively; p<0.005). LUCAS performed no differently than manual CPR in median compression release depth, percent fully released compressions, median time hands off, or percent correct hand position. In our simulation, LUCAS had a higher rate of adequate compressions and decreased total hands-off time as compared to manual CPR. Chest compression quality may be better when using a mechanical device during patient movement in prehospital cardiac arrest patient.
Lukas, Roman-Patrik; Gräsner, Jan Thorsten; Seewald, Stephan; Lefering, Rolf; Weber, Thomas Peter; Van Aken, Hugo; Fischer, Matthias; Bohn, Andreas
2012-10-01
Investigating the effects of any intervention during cardiac arrest remains difficult. The ROSC after cardiac arrest score was introduced to facilitate comparison of rates of return of spontaneous circulation (ROSC) between different ambulance services. To study the influence of chest compression quality management (including training, real-time feedback devices, and debriefing) in comparison with conventional cardiopulmonary resuscitation (CPR), a matched-pair analysis was conducted using data from the German Resuscitation Registry, with the calculated ROSC after cardiac arrest score as the baseline. Matching for independent ROSC after cardiac arrest score variables yielded 319 matched cases from the study period (January 2007-March 2011). The score predicted a 45% ROSC rate for the matched pairs. The observed ROSC increased significantly with chest compression quality management, to 52% (P=0.013; 95% CI, 46-57%). No significant differences were seen in the conventional CPR group (47%; 95% CI, 42-53%). The difference between the observed ROSC rates was not statistically significant. Chest compression quality management leads to significantly higher ROSC rates than those predicted by the prognostic score (ROSC after cardiac arrest score). Matched-pair analysis shows that with conventional CPR, the observed ROSC rate was not significantly different from the predicted rate. Analysis shows a trend toward a higher ROSC rate for chest compression quality management in comparison with conventional CPR. It is unclear whether a single aspect of chest compression quality management or the combination of training, real-time feedback, and debriefing contributed to this result. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Utility of a simple lighting device to improve chest compressions learning.
González-Calvete, L; Barcala-Furelos, R; Moure-González, J D; Abelairas-Gómez, C; Rodríguez-Núñez, A
2017-11-01
The recommendations on cardiopulmonary resuscitation (CPR) emphasize the quality of the manoeuvres, especially chest compressions (CC). Audiovisual feedback devices could improve the quality of the CC during CPR. The aim of this study was to evaluate the usefulness of a simple lighting device as a visual aid during CPR on a mannequin. Twenty-two paediatricians who attended an accredited paediatric CPR course performed, in random order, 2min of CPR on a mannequin without and with the help of a simple lighting device, which flashes at a frequency of 100 cycles per minute. The following CC variables were analyzed using a validated compression quality meter (CPRmeter ® ): depth, decompression, rate, CPR time and percentage of compressions. With the lighting device, participants increased average quality (60.23±54.50 vs. 79.24±9.80%; P=.005), percentage in target depth (48.86±42.67 vs. 72.95±20.25%; P=.036) and rate (35.82±37.54 vs. 67.09±31.95%; P=.024). A simple light device that flashes at the recommended frequency improves the quality of CC performed by paediatric residents on a mannequin. The usefulness of this CPR aid system should be assessed in real patients. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Aramendi, E; Ayala, U; Irusta, U; Alonso, E; Eftestøl, T; Kramer-Johansen, J
2012-06-01
To demonstrate that the instantaneous chest compression rate can be accurately estimated from the transthoracic impedance (TTI), and that this estimated rate can be used in a method to suppress cardiopulmonary resuscitation (CPR) artefacts. A database of 372 records, 87 shockable and 285 non-shockable, from out-of-hospital cardiac arrest episodes, corrupted by CPR artefacts, was analysed. Each record contained the ECG and TTI obtained from the defibrillation pads and the compression depth (CD) obtained from a sternal CPR pad. The chest compression rates estimated using TTI and CD were compared. The CPR artefacts were then filtered using the instantaneous chest compression rates estimated from the TTI or CD signals. The filtering results were assessed in terms of the sensitivity and specificity of the shock advice algorithm of a commercial automated external defibrillator. The correlation between the mean chest compression rates estimated using TTI or CD was r=0.98 (95% confidence interval, 0.97-0.98). The sensitivity and specificity after filtering using CD were 95.4% (88.4-98.6%) and 87.0% (82.6-90.5%), respectively. The sensitivity and specificity after filtering using TTI were 95.4% (88.4-98.6%) and 86.3% (81.8-89.9%), respectively. The instantaneous chest compression rate can be accurately estimated from TTI. The sensitivity and specificity after filtering are similar to those obtained using the CD signal. Our CPR suppression method based exclusively on signals acquired through the defibrillation pads is as accurate as methods based on signals obtained from CPR feedback devices. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Cardiopulmonary resuscitation by chest compression alone or with mouth-to-mouth ventilation.
Hallstrom, A; Cobb, L; Johnson, E; Copass, M
2000-05-25
Despite extensive training of citizens of Seattle in cardiopulmonary resuscitation (CPR), bystanders do not perform CPR in almost half of witnessed cardiac arrests. Instructions in chest compression plus mouth-to-mouth ventilation given by dispatchers over the telephone can require 2.4 minutes. In experimental studies, chest compression alone is associated with survival rates similar to those with chest compression plus mouth-to-mouth ventilation. We conducted a randomized study to compare CPR by chest compression alone with CPR by chest compression plus mouth-to-mouth ventilation. The setting of the trial was an urban, fire-department-based, emergency-medical-care system with central dispatching. In a randomized manner, telephone dispatchers gave bystanders at the scene of apparent cardiac arrest instructions in either chest compression alone or chest compression plus mouth-to-mouth ventilation. The primary end point was survival to hospital discharge. Data were analyzed for 241 patients randomly assigned to receive chest compression alone and 279 assigned to chest compression plus mouth-to-mouth ventilation. Complete instructions were delivered in 62 percent of episodes for the group receiving chest compression plus mouth-to-mouth ventilation and 81 percent of episodes for the group receiving chest compression alone (P=0.005). Instructions for compression required 1.4 minutes less to complete than instructions for compression plus mouth-to-mouth ventilation. Survival to hospital discharge was better among patients assigned to chest compression alone than among those assigned to chest compression plus mouth-to-mouth ventilation (14.6 percent vs. 10.4 percent), but the difference was not statistically significant (P=0.18). The outcome after CPR with chest compression alone is similar to that after chest compression with mouth-to-mouth ventilation, and chest compression alone may be the preferred approach for bystanders inexperienced in CPR.
Fischer, Henrik; Neuhold, Stephanie; Hochbrugger, Eva; Steinlechner, Barbara; Koinig, Herbert; Milosevic, Ljubisa; Havel, Christof; Frantal, Sophie; Greif, Robert
2011-04-01
Cardiopulmonary resuscitation (CPR) during flight is challenging and has to be sustained for long periods. In this setting a mechanical-resuscitation-device (MRD) might improve performance. In this study we compared the quality of resuscitation of trained flight attendants practicing either standard basic life support (BLS) or using a MRD in a cabin-simulator. Prospective, open, randomized and crossover simulation study. Study participants, competent in standard BLS were trained to use the MRD to deliver both chest compressions and ventilation. 39 teams of two rescuers resuscitated a manikin for 12 min in random order, standard BLS or mechanically assisted resuscitation. Primary outcome was "absolute hands-off time" (sum of all periods during which no hand was placed on the chest minus ventilation time). Various parameters describing the quality of chest compression and ventilation were analysed as secondary outcome parameters. Use of the MRD led to significantly less "absolute hands-off time" (164±33 s vs. 205±42 s, p<0.001). The quality of chest compression was comparable among groups, except for a higher compression rate in the standard BLS group (123±14 min(-1) vs. 95±11 min(-1), p<0.001). Tidal volume was higher in the standard BLS group (0.48±0.14 l vs. 0.34±0.13 l, p<0.001), but we registered fewer gastric inflations in the MRD group (0.4±0.3% vs. 16.6±16.9%, p<0.001). Using the MRD resulted in significantly less "absolute hands-off time", but less effective ventilation. The translation of higher chest compression rate into better outcome, as shown in other studies previously, has to be investigated in another human outcome study. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Wang, Chunfei; Zhang, Guang; Wu, Taihu; Zhan, Ningbo; Wang, Yaling
2016-03-01
High-quality cardiopulmonary resuscitation contributes to cardiac arrest survival. The traditional chest compression (CC) standard, which neglects individual differences, uses unified standards for compression depth and compression rate in practice. In this study, an effective and personalized CC method for automatic mechanical compression devices is provided. We rebuild Charles F. Babbs' human circulation model with a coronary perfusion pressure (CPP) simulation module and propose a closed-loop controller based on a fuzzy control algorithm for CCs, which adjusts the CC depth according to the CPP. Compared with a traditional proportion-integration-differentiation (PID) controller, the performance of the fuzzy controller is evaluated in computer simulation studies. The simulation results demonstrate that the fuzzy closed-loop controller results in shorter regulation time, fewer oscillations and smaller overshoot than traditional PID controllers and outperforms the traditional PID controller for CPP regulation and maintenance.
Chung, Tae Nyoung; Bae, Jinkun; Kim, Eui Chung; Cho, Yun Kyung; You, Je Sung; Choi, Sung Wook; Kim, Ok Jun
2013-07-01
Recent studies have shown that there may be an interaction between duty cycle and other factors related to the quality of chest compression. Duty cycle represents the fraction of compression phase. We aimed to investigate the effect of shorter compression phase on average chest compression depth during metronome-guided cardiopulmonary resuscitation. Senior medical students performed 12 sets of chest compressions following the guiding sounds, with three down-stroke patterns (normal, fast and very fast) and four rates (80, 100, 120 and 140 compressions/min) in random sequence. Repeated-measures analysis of variance was used to compare the average chest compression depth and duty cycle among the trials. The average chest compression depth increased and the duty cycle decreased in a linear fashion as the down-stroke pattern shifted from normal to very fast (p<0.001 for both). Linear increase of average chest compression depth following the increase of the rate of chest compression was observed only with normal down-stroke pattern (p=0.004). Induction of a shorter compression phase is correlated with a deeper chest compression during metronome-guided cardiopulmonary resuscitation.
Howe, Andrew; O'Hare, Peter; Crawford, Paul; Delafont, Bruno; McAlister, Olibhear; Di Maio, Rebecca; Clutton, Eddie; Adgey, Jennifer; McEneaney, David
2015-11-01
Optimising the depth and rate of applied chest compressions following out of hospital cardiac arrest is crucial in maintaining end organ perfusion and improving survival. The impedance cardiogram (ICG) measured via defibrillator pads produces a characteristic waveform during chest compressions with the potential to provide feedback on cardiopulmonary resuscitation (CPR) and enhance performance. The objective of this pre-clinical study was to investigate the relationship between mechanical and physiological markers of CPR efficacy in a porcine model and examine the strength of correlation between the ICG amplitude, compression depth and end-tidal CO2 (ETCO2). Two experiments were performed using 24 swine (12 per experiment). For experiment 1, ventricular fibrillation (VF) was induced and mechanical CPR commenced at varying thrusts (0-60 kg) for 2 min intervals. Chest compression depth was recorded using a Philips QCPR device with additional recording of invasive physiological parameters: systolic blood pressure, ETCO2, cardiac output and carotid flow. For experiment 2, VF was induced and mechanical CPR commenced at varying depths (0-5 cm) for 2 min intervals. The ICG was recorded via defibrillator pads attached to the animal's sternum and connected to a Heartsine 500 P defibrillator. ICG amplitude, chest compression depth, systolic blood pressure and ETCO2 were recorded during each cycle. In both experiments the within-animal correlation between the measured parameters was assessed using a mixed effect model. In experiment 1 moderate within-animal correlations were observed between physiological parameters and compression depth (r=0.69-0.77) and thrust (r=0.66-0.82). A moderate correlation was observed between compression depth and thrust (r=0.75). In experiment 2 a strong within-animal correlation and moderate overall correlations were observed between ICG amplitude and compression depth (r=0.89, r=0.79) and ETCO2 (r=0.85, r=0.64). In this porcine model of induced cardiac arrest moderate within animal correlations were observed between mechanical and physiological markers of chest compression efficacy demonstrating the challenge in utilising a single mechanical metric to quantify chest compression efficacy. ICG amplitude demonstrated strong within animal correlations with compression depth and ETCO2 suggesting its potential utility to provide CPR feedback in the out of hospital setting to improve performance. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Niles, Dana E; Duval-Arnould, Jordan; Skellett, Sophie; Knight, Lynda; Su, Felice; Raymond, Tia T; Sweberg, Todd; Sen, Anita I; Atkins, Dianne L; Friess, Stuart H; de Caen, Allan R; Kurosawa, Hiroshi; Sutton, Robert M; Wolfe, Heather; Berg, Robert A; Silver, Annemarie; Hunt, Elizabeth A; Nadkarni, Vinay M
2018-05-01
Pediatric in-hospital cardiac arrest cardiopulmonary resuscitation quality metrics have been reported in few children less than 8 years. Our objective was to characterize chest compression fraction, rate, depth, and compliance with 2015 American Heart Association guidelines across multiple pediatric hospitals. Retrospective observational study of data from a multicenter resuscitation quality collaborative from October 2015 to April 2017. Twelve pediatric hospitals across United States, Canada, and Europe. In-hospital cardiac arrest patients (age < 18 yr) with quantitative cardiopulmonary resuscitation data recordings. None. There were 112 events yielding 2,046 evaluable 60-second epochs of cardiopulmonary resuscitation (196,669 chest compression). Event cardiopulmonary resuscitation metric summaries (median [interquartile range]) by age: less than 1 year (38/112): chest compression fraction 0.88 (0.61-0.98), chest compression rate 119/min (110-129), and chest compression depth 2.3 cm (1.9-3.0 cm); for 1 to less than 8 years (42/112): chest compression fraction 0.94 (0.79-1.00), chest compression rate 117/min (110-124), and chest compression depth 3.8 cm (2.9-4.6 cm); for 8 to less than 18 years (32/112): chest compression fraction 0.94 (0.85-1.00), chest compression rate 117/min (110-123), chest compression depth 5.5 cm (4.0-6.5 cm). "Compliance" with guideline targets for 60-second chest compression "epochs" was predefined: chest compression fraction greater than 0.80, chest compression rate 100-120/min, and chest compression depth: greater than or equal to 3.4 cm in less than 1 year, greater than or equal to 4.4 cm in 1 to less than 8 years, and 4.5 to less than 6.6 cm in 8 to less than 18 years. Proportion of less than 1 year, 1 to less than 8 years, and 8 to less than 18 years events with greater than or equal to 60% of 60-second epochs meeting compliance (respectively): chest compression fraction was 53%, 81%, and 78%; chest compression rate was 32%, 50%, and 63%; chest compression depth was 13%, 19%, and 44%. For all events combined, total compliance (meeting all three guideline targets) was 10% (11/112). Across an international pediatric resuscitation collaborative, we characterized the landscape of pediatric in-hospital cardiac arrest chest compression quality metrics and found that they often do not meet 2015 American Heart Association guidelines. Guideline compliance for rate and depth in children less than 18 years is poor, with the greatest difficulty in achieving chest compression depth targets in younger children.
Tandon, Navin; McCarthy, Matthew; Forehand, Brett; Carlson, Jestin N
2014-10-01
Interruptions in chest compressions during cardiopulmonary resuscitation can negatively impact survival. Several new endotracheal intubation (ETI) techniques including video laryngoscopy may allow for ETI with minimal or no interruptions in chest compressions. We sought to determine the impact of three different ETI techniques upon time to intubation (TTI) in a simulated cardiac arrest during uninterrupted chest compression. We performed a randomised crossover study with a convenience sample of emergency physicians using three different ETI techniques: direct laryngoscopy (DL), GlideScope video laryngoscopy (GVL) and GlideScope video laryngoscopy with bougie (GVL-B). Providers performed ETI on a manikin on a hospital bed with concurrent chest compressions. Our primary outcome, TTI, was defined as the time from insertion of the laryngoscope blade until first breath. Given the correlated nature of the data, we used the paired t test to assess the differences in mean TTIs between GVL minus DL and GVL-B minus DL. We also ran the analysis stratified by provider experience. We enrolled 20 providers with a median TTI (IQR) by device of: DL 27 s (20.3, 35.4), GVL 20.6 s (17.7, 27.1) and GVL-B 60.1 s (39.1, 99). The mean GVL-DL difference was -10.1 s (-17.9-2.3) while the mean GVL-B-DL difference was 45.6 s (19.8-71.4) (p<0.001). The GVL-B required the greatest TTI across providers of varying experience levels. In this simulated model of cardiac arrest with uninterrupted chest compressions, TTI was shorter for GVL than DL while use of the GVL with bougie resulted in longer TTI. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Park, Sang-Sub
2014-01-01
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p< 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p< 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p< 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation.
Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Cho, Young Soon; Chung, Sung Phil; Park, Incheol
2012-01-01
Metronome guidance is a simple and economical feedback system for guiding cardiopulmonary resuscitation (CPR). However, a recent study showed that metronome guidance reduced the depth of chest compression. The results of previous studies suggest that a higher chest compression rate is associated with a better CPR outcome as compared with a lower chest compression rate, irrespective of metronome use. Based on this finding, we hypothesized that a lower chest compression rate promotes a reduction in chest compression depth in the recent study rather than metronome use itself. One minute of chest compression-only CPR was performed following the metronome sound played at 1 of 4 different rates: 80, 100, 120, and 140 ticks/min. Average compression depths (ACDs) and duty cycles were compared using repeated measures analysis of variance, and the values in the absence and presence of metronome guidance were compared. Both the ACD and duty cycle increased when the metronome rate increased (P = .017, <.001). Average compression depths for the CPR procedures following the metronome rates of 80 and 100 ticks/min were significantly lower than those for the procedures without metronome guidance. The ACD and duty cyle for chest compression increase as the metronome rate increases during metronome-guided CPR. A higher rate of chest compression is necessary for metronome-guided CPR to prevent suboptimal quality of chest compression. Copyright © 2012 Elsevier Inc. All rights reserved.
Revolving back to the basics in cardiopulmonary resuscitation.
Roppolo, L P; Wigginton, J G; Pepe, P E
2009-05-01
Since the 1970s, most of the research and debate regarding interventions for cardiopulmonary arrest have focused on advanced life support (ALS) therapies and early defibrillation strategies. During the past decade, however, international guidelines for cardiopulmonary resuscitation (CPR) have not only emphasized the concept of uninterrupted chest compressions, but also improvements in the timing, rate and quality of those compressions. In essence, it has been a ''revolution'' in resuscitation medicine in terms of ''coming full circle'' to the 1960s when basic CPR was first developed. Recent data have indicated the need for minimally-interrupted chest compressions with an accompanying emphasis toward removing rescue ventilation altogether in sudden cardiac arrest, at least in the few minutes after a sudden unheralded collapse. In other studies, transient delays in defibrillation attempts and ALS interventions are even recommended so that basic CPR can be prioritized to first restore and maintain better coronary artery perfusion. New devices have now been developed to modify, in real-time, the performance of basic CPR, during both training and an actual resuscitative effort. Several new adjuncts have been created to augment chest compressions or enhance venous return and evolving technology may now be able to identify ventricular fibrillation (VF) without interrupting chest compressions. A renewed focus on widespread CPR training for the average person has also returned to center stage with ground-breaking training initiatives including validated video-based adult learning courses that can reliably teach and enable long term retention of basic CPR skills and automated external defibrillator (AED) use.
Helicopter-based in-water resuscitation with chest compressions: a pilot study.
Winkler, Bernd E; Hartig, Frank; DuCanto, James; Koch, Andreas; Georgieff, Michael; Lungwitz, Yannick P; Muth, Claus-Martin
2015-07-01
Drowning is a relevant worldwide cause of severe disability and death. The delay of ventilations and chest compressions is a crucial problem in drowning victims. Hence, a novel helicopter-based ALS rescue concept with in-water ventilation and chest compressions was evaluated. Cardio pulmonary resuscitation (CPR) and vascular access were performed in a self-inflating Heliboat platform in an indoor wave pool using the Fastrach intubating laryngeal mask, the Oxylator resuscitator, Lund University Cardiopulmonary Assist System (LUCAS) chest compression device and EZ-IO intraosseous power drill. The time requirement and physical exertion on a Visual Analogue Scale (VAS) were compared between a procedure without waves and with moderate swell. Measurement of the elapsed time of the various stages of the procedure did not reveal significant differences between calm water and swell: Ventilation was initiated after 02:48 versus 03:02 and chest compression after 04:20 versus 04:18 min; the intraosseous cannulisation was completed after 05:59 versus 06:30 min after a simulated jump off the helicopter. The attachment of the LUCAS to the mannequin and the intraosseous cannulisation was rated significantly more demanding on the VAS during swell conditions. CPR appears to be possible when performed in a rescue platform with special equipment. The novel helicopter-based strategy appears to enable the rescuers to initiate CPR in an appropriate length of time and with an acceptable amount of physical exertion for the divers. The time for the helicopter to reach the patient will have to be very short to minimise neurological damage in the drowning victim. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Martin, Philip; Theobald, Peter; Kemp, Alison; Maguire, Sabine; Maconochie, Ian; Jones, Michael
2013-08-01
European and Advanced Paediatric Life Support training courses. Sixty-nine certified CPR providers. CPR providers were randomly allocated to a 'no-feedback' or 'feedback' group, performing two-thumb and two-finger chest compressions on a "physiological", instrumented resuscitation manikin. Baseline data was recorded without feedback, before chest compressions were repeated with one group receiving feedback. Indices were calculated that defined chest compression quality, based upon comparison of the chest wall displacement to the targets of four, internationally recommended parameters: chest compression depth, release force, chest compression rate and compression duty cycle. Baseline data were consistent with other studies, with <1% of chest compressions performed by providers simultaneously achieving the target of the four internationally recommended parameters. During the 'experimental' phase, 34 CPR providers benefitted from the provision of 'real-time' feedback which, on analysis, coincided with a statistical improvement in compression rate, depth and duty cycle quality across both compression techniques (all measures: p<0.001). Feedback enabled providers to simultaneously achieve the four targets in 75% (two-finger) and 80% (two-thumb) of chest compressions. Real-time feedback produced a dramatic increase in the quality of chest compression (i.e. from <1% to 75-80%). If these results transfer to a clinical scenario this technology could, for the first time, support providers in consistently performing accurate chest compressions during infant CPR and thus potentially improving clinical outcomes. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A Novel Method of Newborn Chest Compression: A Randomized Crossover Simulation Study.
Smereka, Jacek; Szarpak, Lukasz; Ladny, Jerzy R; Rodriguez-Nunez, Antonio; Ruetzler, Kurt
2018-01-01
Objective: To compare a novel two-thumb chest compression technique with standard techniques during newborn resuscitation performed by novice physicians in terms of median depth of chest compressions, degree of full chest recoil, and effective compression efficacy. Patients and Methods: The total of 74 novice physicians with less than 1-year work experience participated in the study. They performed chest compressions using three techniques: (A) The new two-thumb technique (nTTT). The novel method of chest compressions in an infant consists in using two thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist. (B) TFT. With this method, the rescuer compresses the sternum with the tips of two fingers. (C) TTHT. Two thumbs are placed over the lower third of the sternum, with the fingers encircling the torso and supporting the back. Results: The median depth of chest compressions for nTTT was 3.8 (IQR, 3.7-3.9) cm, for TFT-2.1 (IQR, 1.7-2.5) cm, while for TTHT-3.6 (IQR, 3.5-3.8) cm. There was a significant difference between nTTT and TFT, and TTHT and TFT ( p < 0.001) for each time interval during resuscitation. The degree of full chest recoil was 93% (IQR, 91-97) for nTTT, 99% (IQR, 96-100) for TFT, and 90% (IQR, 74-91) for TTHT. There was a statistically significant difference in the degree of complete chest relaxation between nTTT and TFT ( p < 0.001), between nTTT and TTHT ( p = 0.016), and between TFT and TTHT ( p < 0.001). Conclusion: The median chest compression depth for nTTT and TTHT is significantly higher than that for TFT. The degree of full chest recoil was highest for TFT, then for nTTT and TTHT. The effective compression efficiency with nTTT was higher than for TTHT and TFT. Our novel newborn chest compression method in this manikin study provided adequate chest compression depth and degree of full chest recoil, as well as very good effective compression efficiency. Further clinical studies are necessary to confirm these initial results.
Advances in clinical studies of cardiopulmonary resuscitation
Chen, Shou-quan
2015-01-01
BACKGROUND: The survival rate of patients after cardiac arrest (CA) remains lower since 2010 International Consensus on Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care (ECC) was published. In clinical trials, the methods and techniques for CPR have been overly described. This article gives an overview of the progress in methods and techniques for CPR in the past years. DATA SOURCES: Original articles about cardiac arrest and CPR from MEDLINE (PubMed) and relevant journals were searched, and most of them were clinical randomized controlled trials (RCTs). RESULTS: Forty-two articles on methods and techniques of CPR were reviewed, including chest compression and conventional CPR, chest compression depth and speed, defibrillation strategies and priority, mechanical and manual chest compression, advanced airway management, impedance threshold device (ITD) and active compression-decompression (ACD) CPR, epinephrine use, and therapeutic hypothermia. The results of studies and related issues described in the international guidelines had been testified. CONCLUSIONS: Although large multicenter studies on CPR are still difficult to carry out, progress has been made in the past 4 years in the methods and techniques of CPR. The results of this review provide evidences for updating the 2015 international guidelines. PMID:26056537
High-quality cardiopulmonary resuscitation.
Nolan, Jerry P
2014-06-01
The quality of cardiopulmonary resuscitation (CPR) impacts on outcome after cardiac arrest. This review will explore the factors that contribute to high-quality CPR and the metrics that can be used to monitor performance. A recent consensus statement from North America defined five key components of high-quality CPR: minimizing interruptions in chest compressions, providing compressions of adequate rate and depth, avoiding leaning on the chest between compressions, and avoiding excessive ventilation. Studies have shown that real-time feedback devices improve the quality of CPR and, in one before-and-after study, outcome from out-of-hospital cardiac arrest. There is evidence for increasing survival rates following out-of-hospital cardiac arrest and this is associated with increasing rates of bystander CPR. The quality of CPR provided by healthcare professionals can be improved with real-time feedback devices. The components of high-quality CPR and the metrics that can be measured and fed back to healthcare professionals have been defined by expert consensus. In the future, real-time feedback based on the physiological responses to CPR may prove more effective.
Cortegiani, Andrea; Russotto, Vincenzo; Montalto, Francesca; Iozzo, Pasquale; Meschis, Roberta; Pugliesi, Marinella; Mariano, Dario; Benenati, Vincenzo; Raineri, Santi Maurizio; Gregoretti, Cesare; Giarratano, Antonino
2017-01-01
High-quality chest compressions are pivotal to improve survival from cardiac arrest. Basic life support training of school students is an international priority. The aim of this trial was to assess the effectiveness of a real-time training software (Laerdal QCPR®) compared to a standard instructor-based feedback for chest compressions acquisition in secondary school students. After an interactive frontal lesson about basic life support and high quality chest compressions, 144 students were randomized to two types of chest compressions training: 1) using Laerdal QCPR® (QCPR group- 72 students) for real-time feedback during chest compressions with the guide of an instructor who considered software data for students' correction 2) based on standard instructor-based feedback (SF group- 72 students). Both groups had a minimum of a 2-minute chest compressions training session. Students were required to reach a minimum technical skill level before the evaluation. We evaluated all students at 7 days from the training with a 2-minute chest compressions session. The primary outcome was the compression score, which is an overall measure of chest compressions quality calculated by the software expressed as percentage. 125 students were present at the evaluation session (60 from QCPR group and 65 from SF group). Students in QCPR group had a significantly higher compression score (median 90%, IQR 81.9-96.0) compared to SF group (median 67%, IQR 27.7-87.5), p = 0.0003. Students in QCPR group performed significantly higher percentage of fully released chest compressions (71% [IQR 24.5-99.0] vs 24% [IQR 2.5-88.2]; p = 0.005) and better chest compression rate (117.5/min [IQR 106-123.5] vs 125/min [115-135.2]; p = 0.001). In secondary school students, a training for chest compressions based on a real-time feedback software (Laerdal QCPR®) guided by an instructor is superior to instructor-based feedback training in terms of chest compression technical skill acquisition. Australian New Zealand Clinical Trials Registry ACTRN12616000383460.
Yeung, Joyce; Chilwan, Mehboob; Field, Richard; Davies, Robin; Gao, Fang; Perkins, Gavin D
2014-07-01
Minimising interruptions in chest compressions is associated with improved survival from cardiac arrest. Current in-hospital guidelines recommend continuous chest compressions after the airway is secured on the premise that this will reduce no flow time. The aim of this study was to determine the effect of advanced airway use on the no flow ratio and other measures of CPR quality. Consecutive adult patients who sustained an in-hospital cardiac arrest were enrolled in this prospective observational study. The quality of CPR was measured using the Q-CPR device (Phillips, UK) before and after an advanced airway device (endotracheal tube [ET] or laryngeal mask airway [LMA]) was inserted. Patients receiving only bag-mask ventilation were used as the control cohort. The primary outcome was no flow ratio (NFR). Secondary outcomes were chest compression rate, depth, compressions too shallow, compressions with leaning, ventilation rate, inflation time, change in impedance and time required to successfully insert airway device. One hundred patients were enrolled in the study (2008-2011). Endotracheal tube and LMA placement took similar durations (median 15.8 s (IQR 6.8-19.4) vs. LMA median 8.0s (IQR 5.5-15.9), p=0.1). The use of an advanced airway was associated with improved no flow ratios (endotracheal tube placement (n=50) improved NFR from baseline median 0.24 IQR 0.17-0.40) to 0.15 to (IQR 0.09-0.28), p=0.012; LMA (n=25) from median 0.28 (IQR 0.23-0.40) to 0.13 (IQR 0.11- 0.19), p=0.0001). There was no change in NFR in patients managed solely with bag valve mask (BVM) (n=25) (median 0.29 (IQR 0.18-0.59) vs. median 0.26 (IQR 0.12-0.37), p=0.888). There was no significant difference in time taken to successfully insert the airway device between the two groups. The use of an advanced airway (ETT or LMA) during in-hospital cardiac arrest was associated with improved no flow ratio. Further studies are required to determine the effect of airway devices on overall patient outcomes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Bae, Jinkun; Chung, Tae Nyoung; Je, Sang Mo
2016-01-01
Objectives To assess how the quality of metronome-guided cardiopulmonary resuscitation (CPR) was affected by the chest compression rate familiarised by training before the performance and to determine a possible mechanism for any effect shown. Design Prospective crossover trial of a simulated, one-person, chest-compression-only CPR. Setting Participants were recruited from a medical school and two paramedic schools of South Korea. Participants 42 senior students of a medical school and two paramedic schools were enrolled but five dropped out due to physical restraints. Intervention Senior medical and paramedic students performed 1 min of metronome-guided CPR with chest compressions only at a speed of 120 compressions/min after training for chest compression with three different rates (100, 120 and 140 compressions/min). Friedman's test was used to compare average compression depths based on the different rates used during training. Results Average compression depths were significantly different according to the rate used in training (p<0.001). A post hoc analysis showed that average compression depths were significantly different between trials after training at a speed of 100 compressions/min and those at speeds of 120 and 140 compressions/min (both p<0.001). Conclusions The depth of chest compression during metronome-guided CPR is affected by the relative difference between the rate of metronome guidance and the chest compression rate practised in previous training. PMID:26873050
Kılıç, D; Göksu, E; Kılıç, T; Buyurgan, C S
2018-05-01
The aim of this randomized cross-over study was to compare one-minute and two-minute continuous chest compressions in terms of chest compression only CPR quality metrics on a mannequin model in the ED. Thirty-six emergency medicine residents participated in this study. In the 1-minute group, there was no statistically significant difference in the mean compression rate (p=0.83), mean compression depth (p=0.61), good compressions (p=0.31), the percentage of complete release (p=0.07), adequate compression depth (p=0.11) or the percentage of good rate (p=51) over the four-minute time period. Only flow time was statistically significant among the 1-minute intervals (p<0.001). In the 2-minute group, the mean compression depth (p=0.19), good compression (p=0.92), the percentage of complete release (p=0.28), adequate compression depth (p=0.96), and the percentage of good rate (p=0.09) were not statistically significant over time. In this group, the number of compressions (248±31 vs 253±33, p=0.01) and mean compression rates (123±15 vs 126±17, p=0.01) and flow time (p=0.001) were statistically significant along the two-minute intervals. There was no statistically significant difference in the mean number of chest compressions per minute, mean chest compression depth, the percentage of good compressions, complete release, adequate chest compression depth and percentage of good compression between the 1-minute and 2-minute groups. There was no statistically significant difference in the quality metrics of chest compressions between 1- and 2-minute chest compression only groups. Copyright © 2017 Elsevier Inc. All rights reserved.
Haffner, Leopold; Mahling, Moritz; Muench, Alexander; Castan, Christoph; Schubert, Paul; Naumann, Aline; Reddersen, Silke; Herrmann-Werner, Anne; Reutershan, Jörg; Riessen, Reimer; Celebi, Nora
2017-03-03
Chest compressions are a core element of cardio-pulmonary resuscitation. Despite periodic training, real-life chest compressions have been reported to be overly shallow and/or fast, very likely affecting patient outcomes. We investigated the effect of a brief Crew Resource Management (CRM) training program on the correction rate of improperly executed chest compressions in a simulated cardiac arrest scenario. Final-year medical students (n = 57) were randomised to receive a 10-min computer-based CRM or a control training on ethics. Acting as team leaders, subjects performed resuscitation in a simulated cardiac arrest scenario before and after the training. Team members performed standardised overly shallow and fast chest compressions. We analysed how often the team leader recognised and corrected improper chest compressions, as well as communication and resuscitation quality. After the CRM training, team leaders corrected improper chest compressions (35.5%) significantly more often compared with those undergoing control training (7.7%, p = 0.03*). Consequently, four students have to be trained (number needed to treat = 3.6) for one improved chest compression scenario. Communication quality assessed by the Leader Behavior Description Questionnaire significantly increased in the intervention group by a mean of 4.5 compared with 2.0 (p = 0.01*) in the control group. A computer-based, 10-min CRM training improved the recognition of ineffective of chest compressions. Furthermore, communication quality increased. As guideline-adherent chest compressions have been linked to improved patient outcomes, our CRM training might represent a brief and affordable approach to increase chest compression quality and potentially improve patient outcomes.
Atkins, Dianne L; de Caen, Allan R; Berger, Stuart; Samson, Ricardo A; Schexnayder, Stephen M; Joyner, Benny L; Bigham, Blair L; Niles, Dana E; Duff, Jonathan P; Hunt, Elizabeth A; Meaney, Peter A
2018-01-02
This focused update to the American Heart Association guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care follows the Pediatric Task Force of the International Liaison Committee on Resuscitation evidence review. It aligns with the International Liaison Committee on Resuscitation's continuous evidence review process, and updates are published when the International Liaison Committee on Resuscitation completes a literature review based on new science. This update provides the evidence review and treatment recommendation for chest compression-only CPR versus CPR using chest compressions with rescue breaths for children <18 years of age. Four large database studies were available for review, including 2 published after the "2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care." Two demonstrated worse 30-day outcomes with chest compression-only CPR for children 1 through 18 years of age, whereas 2 studies documented no difference between chest compression-only CPR and CPR using chest compressions with rescue breaths. When the results were analyzed for infants <1 year of age, CPR using chest compressions with rescue breaths was better than no CPR but was no different from chest compression-only CPR in 1 study, whereas another study observed no differences among chest compression-only CPR, CPR using chest compressions with rescue breaths, and no CPR. CPR using chest compressions with rescue breaths should be provided for infants and children in cardiac arrest. If bystanders are unwilling or unable to deliver rescue breaths, we recommend that rescuers provide chest compressions for infants and children. © 2017 American Heart Association, Inc.
Bae, Jinkun; Chung, Tae Nyoung; Je, Sang Mo
2016-02-12
To assess how the quality of metronome-guided cardiopulmonary resuscitation (CPR) was affected by the chest compression rate familiarised by training before the performance and to determine a possible mechanism for any effect shown. Prospective crossover trial of a simulated, one-person, chest-compression-only CPR. Participants were recruited from a medical school and two paramedic schools of South Korea. 42 senior students of a medical school and two paramedic schools were enrolled but five dropped out due to physical restraints. Senior medical and paramedic students performed 1 min of metronome-guided CPR with chest compressions only at a speed of 120 compressions/min after training for chest compression with three different rates (100, 120 and 140 compressions/min). Friedman's test was used to compare average compression depths based on the different rates used during training. Average compression depths were significantly different according to the rate used in training (p<0.001). A post hoc analysis showed that average compression depths were significantly different between trials after training at a speed of 100 compressions/min and those at speeds of 120 and 140 compressions/min (both p<0.001). The depth of chest compression during metronome-guided CPR is affected by the relative difference between the rate of metronome guidance and the chest compression rate practised in previous training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Evaluation of a newly developed infant chest compression technique
Smereka, Jacek; Bielski, Karol; Ladny, Jerzy R.; Ruetzler, Kurt; Szarpak, Lukasz
2017-01-01
Abstract Background: Providing adequate chest compression is essential during infant cardio-pulmonary-resuscitation (CPR) but was reported to be performed poor. The “new 2-thumb technique” (nTTT), which consists in using 2 thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist, was recently introduced. Therefore, the aim of this study was to compare 3 chest compression techniques, namely, the 2-finger-technique (TFT), the 2-thumb-technique (TTHT), and the nTTT in an randomized infant-CPR manikin setting. Methods: A total of 73 paramedics with at least 1 year of clinical experience performed 3 CPR settings with a chest compression:ventilation ratio of 15:2, according to current guidelines. Chest compression was performed with 1 out of the 3 chest compression techniques in a randomized sequence. Chest compression rate and depth, chest decompression, and adequate ventilation after chest compression served as outcome parameters. Results: The chest compression depth was 29 (IQR, 28–29) mm in the TFT group, 42 (40–43) mm in the TTHT group, and 40 (39–40) mm in the nTTT group (TFT vs TTHT, P < 0.001; TFT vs nTTT, P < 0.001; TTHT vs nTTT, P < 0.01). The median compression rate with TFT, TTHT, and nTTT varied and amounted to 136 (IQR, 133–144) min–1 versus 117 (115–121) min–1 versus 111 (109–113) min–1. There was a statistically significant difference in the compression rate between TFT and TTHT (P < 0.001), TFT and nTTT (P < 0.001), as well as TTHT and nTTT (P < 0.001). Incorrect decompressions after CC were significantly increased in the TTHT group compared with the TFT (P < 0.001) and the nTTT (P < 0.001) group. Conclusions: The nTTT provides adequate chest compression depth and rate and was associated with adequate chest decompression and possibility to adequately ventilate the infant manikin. Further clinical studies are necessary to confirm these initial findings. PMID:28383397
Smereka, Jacek; Bielski, Karol; Ladny, Jerzy R; Ruetzler, Kurt; Szarpak, Lukasz
2017-04-01
Providing adequate chest compression is essential during infant cardio-pulmonary-resuscitation (CPR) but was reported to be performed poor. The "new 2-thumb technique" (nTTT), which consists in using 2 thumbs directed at the angle of 90° to the chest while closing the fingers of both hands in a fist, was recently introduced. Therefore, the aim of this study was to compare 3 chest compression techniques, namely, the 2-finger-technique (TFT), the 2-thumb-technique (TTHT), and the nTTT in an randomized infant-CPR manikin setting. A total of 73 paramedics with at least 1 year of clinical experience performed 3 CPR settings with a chest compression:ventilation ratio of 15:2, according to current guidelines. Chest compression was performed with 1 out of the 3 chest compression techniques in a randomized sequence. Chest compression rate and depth, chest decompression, and adequate ventilation after chest compression served as outcome parameters. The chest compression depth was 29 (IQR, 28-29) mm in the TFT group, 42 (40-43) mm in the TTHT group, and 40 (39-40) mm in the nTTT group (TFT vs TTHT, P < 0.001; TFT vs nTTT, P < 0.001; TTHT vs nTTT, P < 0.01). The median compression rate with TFT, TTHT, and nTTT varied and amounted to 136 (IQR, 133-144) min versus 117 (115-121) min versus 111 (109-113) min. There was a statistically significant difference in the compression rate between TFT and TTHT (P < 0.001), TFT and nTTT (P < 0.001), as well as TTHT and nTTT (P < 0.001). Incorrect decompressions after CC were significantly increased in the TTHT group compared with the TFT (P < 0.001) and the nTTT (P < 0.001) group. The nTTT provides adequate chest compression depth and rate and was associated with adequate chest decompression and possibility to adequately ventilate the infant manikin. Further clinical studies are necessary to confirm these initial findings.
Shih, Andre; Udassi, Sharda; Porvasnik, Stacy L; Lamb, Melissa A; Badugu, Srinivasarao; Venkata, Giridhar Kaliki; Lopez-Colon, Dalia; Haque, Ikram U; Zaritsky, Arno L; Udassi, Jai P
2013-10-01
To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. Controlled, randomized animal study. In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Jäntti, H; Silfvast, T; Turpeinen, A; Kiviniemi, V; Uusaro, A
2009-04-01
The adequate chest compression rate during CPR is associated with improved haemodynamics and primary survival. To explore whether the use of a metronome would affect also chest compression depth beside the rate, we evaluated CPR quality using a metronome in a simulated CPR scenario. Forty-four experienced intensive care unit nurses participated in two-rescuer basic life support given to manikins in 10min scenarios. The target chest compression to ventilation ratio was 30:2 performed with bag and mask ventilation. The rescuer performing the compressions was changed every 2min. CPR was performed first without and then with a metronome that beeped 100 times per minute. The quality of CPR was analysed with manikin software. The effect of rescuer fatigue on CPR quality was analysed separately. The mean compression rate between ventilation pauses was 137+/-18compressions per minute (cpm) without and 98+/-2cpm with metronome guidance (p<0.001). The mean number of chest compressions actually performed was 104+/-12cpm without and 79+/-3cpm with the metronome (p<0.001). The mean compression depth during the scenario was 46.9+/-7.7mm without and 43.2+/-6.3mm with metronome guidance (p=0.09). The total number of chest compressions performed was 1022 without metronome guidance, 42% at the correct depth; and 780 with metronome guidance, 61% at the correct depth (p=0.09 for difference for percentage of compression with correct depth). Metronome guidance corrected chest compression rates for each compression cycle to within guideline recommendations, but did not affect chest compression quality or rescuer fatigue.
Talikowska, Milena; Tohira, Hideo; Finn, Judith
2015-11-01
To conduct a systematic review and meta-analysis to determine whether cardiopulmonary resuscitation (CPR) quality, as indicated by parameters such as chest compression depth, compression rate and compression fraction, is associated with patient survival from cardiac arrest. Five databases were searched (MEDLINE, Embase, CINAHL, Scopus and Cochrane) as well as the grey literature (MedNar). To satisfy inclusion criteria, studies had to document human cases of in- or out-of hospital cardiac arrest where CPR quality had been recorded using an automated device and linked to patient survival. Where indicated (I(2)<75%), meta-analysis was undertaken to examine the relationship between individual CPR quality parameters and either survival to hospital discharge (STHD) or return of spontaneous circulation (ROSC). Database searching yielded 8,842 unique citations, resulting in the inclusion of 22 relevant articles. Thirteen were included in the meta-analysis. Chest compression depth was significantly associated with STHD (mean difference (MD) between survivors and non-survivors 2.59 mm, 95% CI: 0.71, 4.47); and with ROSC (MD 0.99 mm, 95% CI: 0.04, 1.93). Within the range of approximately 100-120 compressions per minute (cpm), compression rate was significantly associated with STHD; survivors demonstrated a lower mean compression rate than non-survivors (MD -1.17 cpm, 95% CI: -2.21, -0.14). Compression fraction could not be examined by meta-analysis due to high heterogeneity, however a higher fraction appeared to be associated with survival in cases with a shockable initial rhythm. Chest compression depth and rate were associated with survival outcomes. More studies with consistent reporting of data are required for other quality parameters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Tension pneumothorax secondary to automatic mechanical compression decompression device.
Hutchings, A C; Darcy, K J; Cumberbatch, G L A
2009-02-01
The details are presented of the first published case of a tension pneumothorax induced by an automatic compression-decompression (ACD) device during cardiac arrest. An elderly patient collapsed with back pain and, on arrival of the crew, was in pulseless electrical activity (PEA) arrest. He was promptly intubated and correct placement of the endotracheal tube was confirmed by noting equal air entry bilaterally and the ACD device applied. On the way to the hospital he was noted to have absent breath sounds on the left without any change in the position of the endotracheal tube. Needle decompression of the left chest caused a hiss of air but the patient remained in PEA. Intercostal drain insertion in the emergency department released a large quantity of air from his left chest but without any change in his condition. Post-mortem examination revealed a ruptured abdominal aortic aneurysm as the cause of death. Multiple left rib fractures and a left lung laceration secondary to the use of the ACD device were also noted, although the pathologist felt that the tension pneumothorax had not contributed to the patient's death. It is recommended that a simple or tension pneumothorax should be considered when there is unilateral absence of breath sounds in addition to endobronchial intubation if an ACD device is being used.
Smereka, Jacek; Szarpak, Lukasz; Rodríguez-Núñez, Antonio; Ladny, Jerzy R; Leung, Steve; Ruetzler, Kurt
2017-10-01
Pediatric cardiac arrest is an uncommon but critical life-threatening event requiring effective cardiopulmonary resuscitation. High-quality cardio-pulmonary resuscitation (CPR) is essential, but is poorly performed, even by highly skilled healthcare providers. The recently described two-thumb chest compression technique (nTTT) consists of the two thumbs directed at the angle of 90° to the chest while having the fingers fist-clenched. This technique might facilitate adequate chest-compression depth, chest-compression rate and rate of full chest-pressure relief. 42 paramedics from the national Emergency Medical Service of Poland performed three single-rescuer CPR sessions for 10 minutes each. Each session was randomly assigned to the conventional two-thumb (TTHT), the conventional two-finger (TFT) or the nTTT. The manikin used for this study was connected with an arterial blood pressure measurement device and blood measurements were documented on a 10-seconds cycle. The nTTT provided significant higher systolic (82 vs. 30 vs. 41 mmHg). A statistically significant difference was noticed between nTTT and TFT (p<.001), nTTT and TTHT (p<0.001), TFT and TTHT (p=0.003). The median diastolic preassure using nTTT was 16 mmHg compared with 9 mmHg for TFT (p<0.001), and 9.5 mmHg for TTHT (p<0.001). Mean arterial pressure using distinct methods varied and amounted to 40 vs. 22. vs. 26 mmHg (nTTT vs. TFT vs. TTHT, respectively). A statistically significant difference was noticed between nTTT and TFT (p<0.001), nTTT and TTEHT (p<0.001), and TFT and TTHT (p<0.001). The highest median pulse pressure was obtained by the nTTT 67.5 mmHg. Pulse pressure was 31.5 mmHg in the TTHT and 24 mmHg in the TFT. The difference between TFT and TTHT (p=0.025), TFT and nTTT (p<0.001), as well as between TTHT and nTTT (p<0.001) were statistically significant. The new nTTT technique generated higher arterial blood pressures compared to established chest compression techniques using an infant manikin model, suggesting a more effective chest compression. Our results have important clinical implications as nTTT was simple to perform and could be widely taught to both healthcare professionals and bystanders. Whether this technique translates to improved outcomes over existing techniques needs further animal studies and subsequent human trials. Copyright © 2017 Elsevier Inc. All rights reserved.
Eichhorn, Stefan; Spindler, Johannes; Polski, Marcin; Mendoza, Alejandro; Schreiber, Ulrich; Heller, Michael; Deutsch, Marcus Andre; Braun, Christian; Lange, Rüdiger; Krane, Markus
2017-05-01
Investigations of compressive frequency, duty cycle, or waveform during CPR are typically rooted in animal research or computer simulations. Our goal was to generate a mechanical model incorporating alternate stiffness settings and an integrated blood flow system, enabling defined, reproducible comparisons of CPR efficacy. Based on thoracic stiffness data measured in human cadavers, such a model was constructed using valve-controlled pneumatic pistons and an artificial heart. This model offers two realistic levels of chest elasticity, with a blood flow apparatus that reflects compressive depth and waveform changes. We conducted CPR at opposing levels of physiologic stiffness, using a LUCAS device, a motor-driven plunger, and a group of volunteers. In high-stiffness mode, blood flow generated by volunteers was significantly less after just 2min of CPR, whereas flow generated by LUCAS device was superior by comparison. Optimal blood flow was obtained via motor-driven plunger, with trapezoidal waveform. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Mirza, Muzna; Brown, Todd B; Saini, Devashish; Pepper, Tracy L; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S
2008-10-01
Cardiopulmonary resuscitation (CPR) with adequate chest compression depth appears to improve first shock success in cardiac arrest. We evaluate the effect of simplification of chest compression instructions on compression depth in dispatcher-assisted CPR protocol. Data from two randomized, double-blinded, controlled trials with identical methodology were combined to obtain 332 records for this analysis. Subjects were randomized to either modified Medical Priority Dispatch System (MPDS) v11.2 protocol or a new simplified protocol. The main difference between the protocols was the instruction to "push as hard as you can" in the simplified protocol, compared to "push down firmly 2in. (5cm)" in MPDS. Data were recorded via a Laerdal ResusciAnne SkillReporter manikin. Primary outcome measures included: chest compression depth, proportion of compressions without error, with adequate depth and with total release. Instructions to "push as hard as you can", compared to "push down firmly 2in. (5cm)", resulted in improved chest compression depth (36.4 mm vs. 29.7 mm, p<0.0001), and improved median proportion of chest compressions done to the correct depth (32% vs. <1%, p<0.0001). No significant difference in median proportion of compressions with total release (100% for both) and average compression rate (99.7 min(-1) vs. 97.5 min(-1), p<0.56) was found. Modifying dispatcher-assisted CPR instructions by changing "push down firmly 2in. (5cm)" to "push as hard as you can" achieved improvement in chest compression depth at no cost to total release or average chest compression rate.
The effect of hydraulic bed movement on the quality of chest compressions.
Park, Maeng Real; Lee, Dae Sup; In Kim, Yong; Ryu, Ji Ho; Cho, Young Mo; Kim, Hyung Bin; Yeom, Seok Ran; Min, Mun Ki
2017-08-01
The hydraulic height control systems of hospital beds provide convenience and shock absorption. However, movements in a hydraulic bed may reduce the effectiveness of chest compressions. This study investigated the effects of hydraulic bed movement on chest compressions. Twenty-eight participants were recruited for this study. All participants performed chest compressions for 2min on a manikin and three surfaces: the floor (Day 1), a firm plywood bed (Day 2), and a hydraulic bed (Day 3). We considered 28 participants of Day 1 as control and each 28 participants of Day 2 and Day 3 as study subjects. The compression rates, depths, and good compression ratios (>5-cm compressions/all compressions) were compared between the three surfaces. When we compared the three surfaces, we did not detect a significant difference in the speed of chest compressions (p=0.582). However, significantly lower values were observed on the hydraulic bed in terms of compression depth (p=0.001) and the good compression ratio (p=0.003) compared to floor compressions. When we compared the plywood and hydraulic beds, we did not detect significant differences in compression depth (p=0.351) and the good compression ratio (p=0.391). These results indicate that the movements in our hydraulic bed were associated with a non-statistically significant trend towards lower-quality chest compressions. Copyright © 2017 Elsevier Inc. All rights reserved.
Mirza, Muzna; Brown, Todd B.; Saini, Devashish; Pepper, Tracy L; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S.
2008-01-01
Background and Objective Cardiopulmonary Resuscitation (CPR) with adequate chest compression depth appears to improve first shock success in cardiac arrest. We evaluate the effect of simplification of chest compression instructions on compression depth in dispatcher-assisted CPR protocol. Methods Data from two randomized, double-blinded, controlled trials with identical methodology were combined to obtain 332 records for this analysis. Subjects were randomized to either modified Medical Priority Dispatch System (MPDS) v11.2 protocol or a new simplified protocol. The main difference between the protocols was the instruction to “push as hard as you can” in the simplified protocol, compared to “push down firmly 2 inches (5cm)” in MPDS. Data were recorded via a Laerdal® ResusciAnne® SkillReporter™ manikin. Primary outcome measures included: chest compression depth, proportion of compressions without error, with adequate depth and with total release. Results Instructions to “push as hard as you can”, compared to “push down firmly 2 inches (5cm)”, resulted in improved chest compression depth (36.4 vs 29.7 mm, p<0.0001), and improved median proportion of chest compressions done to the correct depth (32% vs <1%, p<0.0001). No significant difference in median proportion of compressions with total release (100% for both) and average compression rate (99.7 vs 97.5 per min, p<0.56) was found. Conclusions Modifying dispatcher-assisted CPR instructions by changing “push down firmly 2 inches (5cm)” to “push as hard as you can” achieved improvement in chest compression depth at no cost to total release or average chest compression rate. PMID:18635306
2014-01-01
Background According to the guidelines for cardiopulmonary resuscitation (CPR), the rotation time for chest compression should be about 2 min. The quality of chest compressions is related to the physical fitness of the rescuer, but this was not considered when determining rotation time. The present study aimed to clarify associations between body weight and the quality of chest compression and physical fatigue during CPR performed by 18 registered nurses (10 male and 8 female) assigned to light and heavy groups according to the average weight for each sex in Japan. Methods Five-minute chest compressions were then performed on a manikin that was placed on the floor. Measurement parameters were compression depth, heart rate, oxygen uptake, integrated electromyography signals, and rating of perceived exertion. Compression depth was evaluated according to the ratio (%) of adequate compressions (at least 5 cm deep). Results The ratio of adequate compressions decreased significantly over time in the light group. Values for heart rate, oxygen uptake, muscle activity defined as integrated electromyography signals, and rating of perceived exertion were significantly higher for the light group than for the heavy group. Conclusion Chest compression caused increased fatigue among the light group, which consequently resulted in a gradual fall in the quality of chest compression. These results suggested that individuals with a lower body weight should rotate at 1-min intervals to maintain high quality CPR and thus improve the survival rates and neurological outcomes of victims of cardiac arrest. PMID:24957919
The prevalence of chest compression leaning during in-hospital cardiopulmonary resuscitation
Fried, David A.; Leary, Marion; Smith, Douglas A.; Sutton, Robert M.; Niles, Dana; Herzberg, Daniel L.; Becker, Lance B.; Abella, Benjamin S.
2011-01-01
Objective Successful resuscitation from cardiac arrest requires the delivery of high-quality chest compressions, encompassing parameters such as adequate rate, depth, and full recoil between compressions. The lack of compression recoil (“leaning” or “incomplete recoil”) has been shown to adversely affect hemodynamics in experimental arrest models, but the prevalence of leaning during actual resuscitation is poorly understood. We hypothesized that leaning varies across resuscitation events, possibly due to rescuer and/or patient characteristics and may worsen over time from rescuer fatigue during continuous chest compressions. Methods This was an observational clinical cohort study at one academic medical center. Data were collected from adult in-hospital and Emergency Department arrest events using monitor/defibrillators that record chest compression characteristics and provide real-time feedback. Results We analyzed 112,569 chest compressions from 108 arrest episodes from 5/2007 to 2/2009. Leaning was present in 98/108 (91%) cases; 12% of all compressions exhibited leaning. Leaning varied widely across cases: 41/108 (38%) of arrest episodes exhibited <5% leaning yet 20/108 (19%) demonstrated >20% compression leaning. When evaluating blocks of continuous compressions (>120 sec), only 4/33 (12%) had an increase in leaning over time and 29/33 (88%) showed a decrease (p<0.001). Conclusions Chest compression leaning was common during resuscitation care and exhibited a wide distribution, with most leaning within a subset of resuscitations. Leaning decreased over time during continuous chest compression blocks, suggesting that either leaning may not be a function of rescuer fatiguing, or that it may have been mitigated by automated feedback provided during resuscitation episodes. PMID:21482010
Blewer, Audrey L; Leary, Marion; Esposito, Emily C; Gonzalez, Mariana; Riegel, Barbara; Bobrow, Bentley J; Abella, Benjamin S
2012-03-01
Recent work suggests that delivery of continuous chest compression cardiopulmonary resuscitation is an acceptable layperson resuscitation strategy, although little is known about layperson preferences for training in continuous chest compression cardiopulmonary resuscitation. We hypothesized that continuous chest compression cardiopulmonary resuscitation education would lead to greater trainee confidence and would encourage wider dissemination of cardiopulmonary resuscitation skills compared to standard cardiopulmonary resuscitation training (30 compressions: two breaths). Prospective, multicenter randomized study. Three academic medical center inpatient wards. Adult family members or friends (≥ 18 yrs old) of inpatients admitted with cardiac-related diagnoses. In a multicenter randomized trial, family members of hospitalized patients were trained via the educational method of video self-instruction. Subjects were randomized to continuous chest compression cardiopulmonary resuscitation or standard cardiopulmonary resuscitation educational modes. Cardiopulmonary resuscitation performance data were collected using a cardiopulmonary resuscitation skill-reporting manikin. Trainee perspectives and secondary training rates were assessed through mixed qualitative and quantitative survey instruments. Chest compression performance was similar in both groups. The trainees in the continuous chest compression cardiopulmonary resuscitation group were significantly more likely to express a desire to share their training kit with others (152 of 207 [73%] vs. 133 of 199 [67%], p = .03). Subjects were contacted 1 month after initial enrollment to assess actual sharing, or "secondary training." Kits were shared with 2.0 ± 3.4 additional family members in the continuous chest compression cardiopulmonary resuscitation group vs. 1.2 ± 2.2 in the standard cardiopulmonary resuscitation group (p = .03). As a secondary result, trainees in the continuous chest compression cardiopulmonary resuscitation group were more likely to rate themselves "very comfortable" with the idea of using cardiopulmonary resuscitation skills in actual events than the standard cardiopulmonary resuscitation trainees (71 of 207 [34%] vs. 57 of 199 [28%], p = .08). Continuous chest compression cardiopulmonary resuscitation education resulted in a statistically significant increase in secondary training. This work suggests that implementation of video self-instruction training programs using continuous chest compression cardiopulmonary resuscitation may confer broader dissemination of life-saving skills and may promote rescuer comfort with newly acquired cardiopulmonary resuscitation knowledge. URL: http://clinicaltrials.gov. Unique identifier: NCT01260441.
Blewer, Audrey L.; Leary, Marion; Esposito, Emily C.; Gonzalez, Mariana; Riegel, Barbara; Bobrow, Bentley J.; Abella, Benjamin S.
2013-01-01
Objective Recent work suggests that delivery of continuous chest compression cardiopulmonary resuscitation is an acceptable layperson resuscitation strategy, although little is known about layperson preferences for cardiopulmonary resuscitation training in continuous chest compression cardiopulmonary resuscitation. We hypothesized that continuous chest compression cardiopulmonary resuscitation education would lead to greater trainee confidence and would encourage wider dissemination of cardiopulmonary resuscitation skills compared to standard cardiopulmonary resuscitation training (30 compressions: two breaths). Design Prospective, multicenter cohort study. Setting Three academic medical center inpatient wards. Subjects Adult family members or friends (≥18 yrs old) of inpatients admitted with cardiac-related diagnoses. Interventions In a multicenter randomized trial, family members of hospitalized patients were trained via the educational method of video self-instruction. Subjects were randomized to continuous chest compression cardiopulmonary resuscitation or standard cardiopulmonary resuscitation educational modes. Measurements Cardiopulmonary resuscitation performance data were collected using a cardiopulmonary resuscitation skill-reporting manikin. Trainee perspectives and secondary training rates were assessed through mixed qualitative and quantitative survey instruments. Main Results Chest compression performance was similar in both groups. The trainees in the continuous chest compression cardiopulmonary resuscitation group were significantly more likely to express a desire to share their training kit with others (152 of 207 [73%] vs. 133 of 199 [67%], p = .03). Subjects were contacted 1 month after initial enrollment to assess actual sharing, or “secondary training.” Kits were shared with 2.0 ± 3.4 additional family members in the continuous chest compression cardiopulmonary resuscitation group vs. 1.2 ± 2.2 in the standard cardiopulmonary resuscitation group (p = .03). As a secondary result, trainees in the continuous chest compression cardiopulmonary resuscitation group were more likely to rate themselves “very comfortable” with the idea of using cardiopulmonary resuscitation skills in actual events than the standard cardiopulmonary resuscitation trainees (71 of 207 [34%] vs. 57 of 199 [28%], p = .08). Conclusions Continuous chest compression cardiopulmonary resuscitation education resulted in a statistically significant increase in secondary training. This work suggests that implementation of video self-instruction training programs using continuous chest compression cardiopulmonary resuscitation may confer broader dissemination of life-saving skills and may promote rescuer comfort with newly acquired cardiopulmonary resuscitation knowledge. Clinical Trial Registration URL: http://clinicaltrials.gov. Unique identifier: NCT01260441. PMID:22080629
Nishiyama, Chika; Iwami, Taku; Kitamura, Tetsuhisa; Ando, Masahiko; Sakamoto, Tetsuya; Marukawa, Seishiro; Kawamura, Takashi
2014-01-01
It is unclear how much the length of a cardiopulmonary resuscitation (CPR) training program can be reduced without ruining its effectiveness. The authors aimed to compare CPR skills 6 months and 1 year after training between shortened chest compression-only CPR training and conventional CPR training. Participants were randomly assigned to either the compression-only CPR group, which underwent a 45-minute training program consisting of chest compressions and automated external defibrillator (AED) use with personal training manikins, or the conventional CPR group, which underwent a 180-minute training program with chest compressions, rescue breathing, and AED use. Participants' resuscitation skills were evaluated 6 months and 1 year after the training. The primary outcome measure was the proportion of appropriate chest compressions 1 year after the training. A total of 146 persons were enrolled, and 63 (87.5%) in the compression-only CPR group and 56 (75.7%) in the conventional CPR group completed the 1-year evaluation. The compression-only CPR group was superior to the conventional CPR group regarding the proportion of appropriate chest compression (mean ± SD = 59.8% ± 40.0% vs. 46.3% ± 28.6%; p = 0.036) and the number of appropriate chest compressions (mean ± SD = 119.5 ± 80.0 vs. 77.2 ± 47.8; p = 0.001). Time without chest compression in the compression-only CPR group was significantly shorter than that in the conventional CPR group (mean ± SD = 11.8 ± 21.1 seconds vs. 52.9 ± 14.9 seconds; p < 0.001). The shortened compression-only CPR training program appears to help the general public retain CPR skills better than the conventional CPR training program. UMIN-CTR UMIN000001675. © 2013 by the Society for Academic Emergency Medicine.
Leturiondo, Mikel; Ruiz de Gauna, Sofía; Ruiz, Jesus M; Julio Gutiérrez, J; Leturiondo, Luis A; González-Otero, Digna M; Russell, James K; Zive, Dana; Daya, Mohamud
2018-03-01
Capnography has been proposed as a method for monitoring the ventilation rate during cardiopulmonary resuscitation (CPR). A high incidence (above 70%) of capnograms distorted by chest compression induced oscillations has been previously reported in out-of-hospital (OOH) CPR. The aim of the study was to better characterize the chest compression artefact and to evaluate its influence on the performance of a capnogram-based ventilation detector during OOH CPR. Data from the MRx monitor-defibrillator were extracted from OOH cardiac arrest episodes. For each episode, presence of chest compression artefact was annotated in the capnogram. Concurrent compression depth and transthoracic impedance signals were used to identify chest compressions and to annotate ventilations, respectively. We designed a capnogram-based ventilation detection algorithm and tested its performance with clean and distorted episodes. Data were collected from 232 episodes comprising 52 654 ventilations, with a mean (±SD) of 227 (±118) per episode. Overall, 42% of the capnograms were distorted. Presence of chest compression artefact degraded algorithm performance in terms of ventilation detection, estimation of ventilation rate, and the ability to detect hyperventilation. Capnogram-based ventilation detection during CPR using our algorithm was compromised by the presence of chest compression artefact. In particular, artefact spanning from the plateau to the baseline strongly degraded ventilation detection, and caused a high number of false hyperventilation alarms. Further research is needed to reduce the impact of chest compression artefact on capnographic ventilation monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Real-Time Mobile Device-Assisted Chest Compression During Cardiopulmonary Resuscitation.
Sarma, Satyam; Bucuti, Hakiza; Chitnis, Anurag; Klacman, Alex; Dantu, Ram
2017-07-15
Prompt administration of high-quality cardiopulmonary resuscitation (CPR) is a key determinant of survival from cardiac arrest. Strategies to improve CPR quality at point of care could improve resuscitation outcomes. We tested whether a low cost and scalable mobile phone- or smart watch-based solution could provide accurate measures of compression depth and rate during simulated CPR. Fifty health care providers (58% intensive care unit nurses) performed simulated CPR on a calibrated training manikin (Resusci Anne, Laerdal) while wearing both devices. Subjects received real-time audiovisual feedback from each device sequentially. Primary outcome was accuracy of compression depth and rate compared with the calibrated training manikin. Secondary outcome was improvement in CPR quality as defined by meeting both guideline-recommend compression depth (5 to 6 cm) and rate (100 to 120/minute). Compared with the training manikin, typical error for compression depth was <5 mm (smart phone 4.6 mm; 95% CI 4.1 to 5.3 mm; smart watch 4.3 mm; 95% CI 3.8 to 5.0 mm). Compression rates were similarly accurate (smart phone Pearson's R = 0.93; smart watch R = 0.97). There was no difference in improved CPR quality defined as the number of sessions meeting both guideline-recommended compression depth (50 to 60 mm) and rate (100 to 120 compressions/minute) with mobile device feedback (60% vs 50%; p = 0.3). Sessions that did not meet guideline recommendations failed primarily because of inadequate compression depth (46 ± 2 mm). In conclusion, a mobile device application-guided CPR can accurately track compression depth and rate during simulation in a practice environment in accordance with resuscitation guidelines. Copyright © 2017 Elsevier Inc. All rights reserved.
LUCAS(™)2 in Danish Search and Rescue Helicopters.
Winther, Kasper; Bleeg, René Christian
2016-01-01
Prehospital resuscitation is often challenging. Giving uninterrupted and effective compressions is relatively impossible during transportation. In 2012, The Royal Danish Air Force received a donation of 8 mechanical chest compression devices (LUCAS(™)2; Physio-Control/Jolife AB, Lund, Sweden) to be used onboard the Danish search and rescue (SAR) helicopters. The scope of this investigation was to establish whether or not mechanical chest compression devices should be considered a necessity onboard the Danish SAR helicopters. Data were compiled from SAR medical journals. From the data collected, observations were made as to when LUCAS(™)2 was used and what diagnosis the SAR physician made. One thousand ninety missions were registered in the 24-month research period, and LUCAS(™)2 was used in 25 missions. Cardiac emergencies amounted for 25% of the missions. The Danish SAR helicopters retrieved 33 drowned/hypothermic patients during the research period, and the LUCAS(™)2 was used in 11 of the patients requiring resuscitation. The LUCAS(™)2 was frequently used during other emergencies like sudden cardiac arrest. Cardiac emergencies were the predominant type of mission. LUCAS(™)2 is now considered mandatory on Danish SAR helicopters. Copyright © 2016 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.
Lee, Seong Hwa; Ryu, Ji Ho; Min, Mun Ki; Kim, Yong In; Park, Maeng Real; Yeom, Seok Ran; Han, Sang Kyoon; Park, Seong Wook
2016-08-01
When performing cardiopulmonary resuscitation (CPR), the 2010 American Heart Association guidelines recommend a chest compression rate of at least 100 min, whereas the 2010 European Resuscitation Council guidelines recommend a rate of between 100 and 120 min. The aim of this study was to examine the rate of chest compression that fulfilled various quality indicators, thereby determining the optimal rate of compression. Thirty-two trainee emergency medical technicians and six paramedics were enrolled in this study. All participants had been trained in basic life support. Each participant performed 2 min of continuous compressions on a skill reporter manikin, while listening to a metronome sound at rates of 100, 120, 140, and 160 beats/min, in a random order. Mean compression depth, incomplete chest recoil, and the proportion of correctly performed chest compressions during the 2 min were measured and recorded. The rate of incomplete chest recoil was lower at compression rates of 100 and 120 min compared with that at 160 min (P=0.001). The numbers of compressions that fulfilled the criteria for high-quality CPR at a rate of 120 min were significantly higher than those at 100 min (P=0.016). The number of high-quality CPR compressions was the highest at a compression rate of 120 min, and increased incomplete recoil occurred with increasing compression rate. However, further studies are needed to confirm the results.
Deschilder, Koen; De Vos, Rien; Stockman, Willem
2007-07-01
Recent cardio pulmonary resuscitation (CPR) guidelines changed the compression:ventilation ratio in 30:2. To compare the quality of chest compressions and exhaustion using the ratio 30:2 versus 15:2. A prospective, randomised crossover design was used. Subjects were recruited from the H.-Hart hospital personnel and the University College Katho for nurses and bio-engineering. Each participant performed 5min of CPR using either the ratio 30:2 or 15:2, then after a 15min rest switched to the other ratio. The data were collected using a questionnaire and an adult resuscitation manikin. The outcomes included exhaustion as measured by a visual analogue scale (VAS) score, depth of chest compressions, rates of chest compressions, total number of chest compressions, number of correct chest compressions and incomplete release. Data were compared using the Wilcoxon Signed Ranks Test. The results are presented as medians and interquartile ranges (IQR). One hundred and thirty subjects completed the study. The exhaustion-score using the VAS was 5.9 (IQR 2.25) for the ratio 30:2 and 4.5 (IQR 2.88) for the ratio 15:2 (P<0.001). The compression depth was 40.5mm (IQR 15.75) for 30:2 and 41mm (IQR 15.5) for 15:2 (P=0.5). The compression rate was 118beats/min (IQR 29) for 30:2 and 115beats/min (IQR 32) for 15:2 (P=0.02). The total number of compressions/5min was 347 (IQR 79) for 30:2 and 244compressions/5min (IQR 72.5) for 15:2 (P<0.001). The number of correct compression/5min was 61.5 (IQR 211.75) for 30:2 and 55.5 (IQR 142.75) for 15:2 (P=0.001). The relative risk (RR) of incomplete release in 30:2 versus 15:2 was 1.087 (95% CI=0.633-1.867). Although the 30:2 ratio is rated to be more exhausting, the 30:2 technique delivers more chest compressions and the quality of chest compressions remains unchanged.
Chest compression rate measurement from smartphone video.
Engan, Kjersti; Hinna, Thomas; Ryen, Tom; Birkenes, Tonje S; Myklebust, Helge
2016-08-11
Out-of-hospital cardiac arrest is a life threatening situation where the first person performing cardiopulmonary resuscitation (CPR) most often is a bystander without medical training. Some existing smartphone apps can call the emergency number and provide for example global positioning system (GPS) location like Hjelp 113-GPS App by the Norwegian air ambulance. We propose to extend functionality of such apps by using the built in camera in a smartphone to capture video of the CPR performed, primarily to estimate the duration and rate of the chest compression executed, if any. All calculations are done in real time, and both the caller and the dispatcher will receive the compression rate feedback when detected. The proposed algorithm is based on finding a dynamic region of interest in the video frames, and thereafter evaluating the power spectral density by computing the fast fourier transform over sliding windows. The power of the dominating frequencies is compared to the power of the frequency area of interest. The system is tested on different persons, male and female, in different scenarios addressing target compression rates, background disturbances, compression with mouth-to-mouth ventilation, various background illuminations and phone placements. All tests were done on a recording Laerdal manikin, providing true compression rates for comparison. Overall, the algorithm is seen to be promising, and it manages a number of disturbances and light situations. For target rates at 110 cpm, as recommended during CPR, the mean error in compression rate (Standard dev. over tests in parentheses) is 3.6 (0.8) for short hair bystanders, and 8.7 (6.0) including medium and long haired bystanders. The presented method shows that it is feasible to detect the compression rate of chest compressions performed by a bystander by placing the smartphone close to the patient, and using the built-in camera combined with a video processing algorithm performed real-time on the device.
Moore, Johanna C; Lamhaut, Lionel; Hutin, Alice; Dodd, Kenneth W; Robinson, Aaron E; Lick, Michael C; Salverda, Bayert J; Hinke, Mason B; Labarere, José; Debaty, Guillaume; Segal, Nicolas
2017-10-01
The purpose of this study was to examine continuous oxygen insufflation (COI) in a swine model of cardiac arrest. The primary hypothesis was COI during standard CPR (S-CPR) should result in higher intrathoracic pressure (ITP) during chest compression and lower ITP during decompression versus S-CPR alone. These changes with COI were hypothesized to improve hemodynamics. The second hypothesis was that changes in ITP with S-CPR+COI would result in superior hemodynamics compared with active compression decompression (ACD) + impedance threshold device (ITD) CPR, as this method primarily lowers ITP during chest decompression. After 6min of untreated ventricular fibrillation, S-CPR was initiated in 8 female swine for 4min, then 3min of S-CPR+COI, then 3min of ACD+ITD CPR, then 3min of S-CPR+COI. ITP and hemodynamics were continuously monitored. During S-CPR+COI, ITP was always positive during the CPR compression and decompression phases. ITP compression values with S-CPR+COI versus S-CPR alone were 5.5±3 versus 0.2±2 (p<0.001) and decompression values were 2.8±2 versus -1.3±2 (p<0.001), respectively. With S-CPR+COI versus ACD+ITD the ITP compression values were 5.5±3 versus 1.5±2 (p<0.01) and decompression values were 2.8±2 versus -4.7±3 (p<0.001), respectively. COI during S-CPR created a continuous positive pressure in the airway during both the compression and decompression phase of CPR. At no point in time did COI generate a negative intrathoracic pressures during CPR in this swine model of cardiac arrest. Copyright © 2017 Elsevier B.V. All rights reserved.
Quality of Basic Life Support - A Comparison between Medical Students and Paramedics.
Körber, Maria Isabel; Köhler, Thomas; Weiss, Verena; Pfister, Roman; Michels, Guido
2016-07-01
Poor survival rates after cardiac arrest can partly be explained by poor basic life support skills in medical professionals. This study aimed to assess quality of basic life support in medical students and paramedics. We conducted a prospective observational study with 100 early medical students (group A), 100 late medical students (group B) and 100 paramedics (group C), performing a 20-minute basic life support simulation in teams of two. Average frequency and absolute number of chest compressions per minute (mean (±SD)), chest decompression (millimetres of compression remaining, mean (±SD)), hands-off-time (seconds/minute, mean (±SD)), frequency of switching positions between ventilation and chest compression (per 20 minutes) and rate of sufficient compressions (depth ≥50mm) were assessed as quality parameters of CPR. In groups A, B and C the rates of sufficiently deep chest compressions were 56%, 42% and 52%, respectively, without significant differences. Male gender and real-life CPR experience were significantly associated with deeper chest compression. Frequency and number of chest compressions were within recommended goals in at least 96% of all groups. Remaining chest compressions were 6 mm (±2), 6 mm (±2) and 5 mm (±2) with a significant difference between group A and C (p=0.017). Hands-off times were 6s/min (±1), 5s/min (±1) and 4s/min (±1), which was significantly different across all three groups. Overall, paramedics tended to show better quality of CPR compared to medical students. Though, chest compression depth as an important quality characteristic of CPR was insufficient in almost 50% of participants, even in well trained paramedics. Therefore, we suggest that an effort should be made to find better ways to educate health care professionals in BLS.
Choi, Bryan; Asselin, Nicholas; Pettit, Catherine C; Dannecker, Max; Machan, Jason T; Merck, Derek L; Merck, Lisa H; Suner, Selim; Williams, Kenneth A; Jay, Gregory D; Kobayashi, Leo
2016-12-01
Effective resuscitation of out-of-hospital cardiac arrest (OHCA) patients is challenging. Alternative resuscitative approaches using electromechanical adjuncts may improve provider performance. Investigators applied simulation to study the effect of an experimental automation-assisted, goal-directed OHCA management protocol on EMS providers' resuscitation performance relative to standard protocols and equipment. Two-provider (emergency medical technicians (EMT)-B and EMT-I/C/P) teams were randomized to control or experimental group. Each team engaged in 3 simulations: baseline simulation (standard roles); repeat simulation (standard roles); and abbreviated repeat simulation (reversed roles, i.e., basic life support provider performing ALS tasks). Control teams used standard OHCA protocols and equipment (with high-performance cardiopulmonary resuscitation training intervention); for second and third simulations, experimental teams performed chest compression, defibrillation, airway, pulmonary ventilation, vascular access, medication, and transport tasks with goal-directed protocol and resuscitation-automating devices. Videorecorders and simulator logs collected resuscitation data. Ten control and 10 experimental teams comprised 20 EMT-B's; 1 EMT-I, 8 EMT-C's, and 11 EMT-P's; study groups were not fully matched. Both groups suboptimally performed chest compressions and ventilations at baseline. For their second simulations, control teams performed similarly except for reduced on-scene time, and experimental teams improved their chest compressions (P=0.03), pulmonary ventilations (P<0.01), and medication administration (P=0.02); changes in their performance of chest compression, defibrillation, airway, and transport tasks did not attain significance against control teams' changes. Experimental teams maintained performance improvements during reversed-role simulations. Simulation-based investigation into OHCA resuscitation revealed considerable variability and improvable deficiencies in small EMS teams. Goal-directed, automation-assisted OHCA management augmented select resuscitation bundle element performance without comprehensive improvement.
NASA Astrophysics Data System (ADS)
Krygiel, Rebecca G.; Waye, Abigail B.; Baptista, Rafael Reimann; Heidner, Gustavo Sandri; Rehnberg, Lucas; Russomano, Thais
2014-04-01
BACKGROUND: This original study evaluated the electromyograph (EMG) activity of four upper body muscles: triceps brachii, erector spinae, upper rectus abdominis, and pectoralis major, while external chest compressions (ECCs) were performed in simulated Martian hypogravity using a Body Suspension Device, counterweight system, and standard full body cardiopulmonary resuscitation (CPR) mannequin. METHOD: 20 young, healthy male subjects were recruited. One hundred compressions divided into four sets, with roughly six seconds between each set to indicate 'ventilation', were performed within approximately a 1.5 minute protocol. Chest compression rate, depth and number were measured along with the subject's heart rate (HR) and rating of perceived exertion (RPE). RESULTS: All mean values were used in two-tailed t-tests using SPSS to compare +1 Gz values (control) versus simulated hypogravity values. The AHA (2005) compression standards were maintained in hypogravity. RPE and HR increased by 32% (p < 0.001) and 44% (p = 0.002), respectively, when ECCs were performed during Mars simulation, in comparison to +1 Gz. In hypogravity, the triceps brachii showed significantly less activity (p < 0.001) when compared with the other three muscles studied. The comparison of all the other muscles showed no difference at +1 Gz or in hypogravity. CONCLUSIONS: This study was among the first of its kind, however several limitations were faced which hopefully will not exist in future studies. Evaluation of a great number of muscles will allow space crews to focus on specific strengthening exercises within their current training regimes in case of a serious cardiac event in hypogravity.
Zhang, Hehua; Yang, Zhengfei; Huang, Zitong; Chen, Bihua; Zhang, Lei; Li, Heng; Wu, Baoming; Yu, Tao; Li, Yongqin
2012-10-01
The quality of cardiopulmonary resuscitation (CPR), especially adequate compression depth, is associated with return of spontaneous circulation (ROSC) and is therefore recommended to be measured routinely. In the current study, we investigated the relationship between changes of transthoracic impedance (TTI) measured through the defibrillation electrodes, chest compression depth and coronary perfusion pressure (CPP) in a porcine model of cardiac arrest. In 14 male pigs weighing between 28 and 34 kg, ventricular fibrillation (VF) was electrically induced and untreated for 6 min. Animals were randomized to either optimal or suboptimal chest compression group. Optimal depth of manual compression in 7 pigs was defined as a decrease of 25% (50 mm) in anterior posterior diameter of the chest, while suboptimal compression was defined as 70% of the optimal depth (35 mm). After 2 min of chest compression, defibrillation was attempted with a 120-J rectilinear biphasic shock. There were no differences in baseline measurements between groups. All animals had ROSC after optimal compressions; this contrasted with suboptimal compressions, after which only 2 of the animals had ROSC (100% vs. 28.57%, p=0.021). The correlation coefficient was 0.89 between TTI amplitude and compression depth (p<0.001), 0.83 between TTI amplitude and CPP (p<0.001). Amplitude change of TTI was correlated with compression depth and CPP in this porcine model of cardiac arrest. The TTI measured from defibrillator electrodes, therefore has the potential to serve as an indicator to monitor the quality of chest compression and estimate CPP during CPR. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Waninger, Kevin N; Goodbred, Andrew; Vanic, Keith; Hauth, John; Onia, Joshua; Stoltzfus, Jill; Melanson, Scott
2014-07-01
To investigate (1) cardiopulmonary resuscitation (CPR) adequacy during simulated cardiac arrest of equipped football players and (2) whether protective football equipment impedes CPR performance measures. Exploratory crossover study performed on Laerdal SimMan 3 G interactive manikin simulator. Temple University/St Luke's University Health Network Regional Medical School Simulation Laboratory. Thirty BCLS-certified ATCs and 6 ACLS-certified emergency department technicians. Subjects were given standardized rescuer scenarios to perform three 2-minute sequences of compression-only CPR. Baseline CPR sequences were captured on each subject. Experimental conditions included 2-minute sequences of CPR either over protective football shoulder pads or under unlaced pads. Subjects were instructed to adhere to 2010 American Heart Association guidelines (initiation of compressions alone at 100/min to 51 mm). Dependent variables included average compression depth, average compression rate, percentage of time chest wall recoiled, and percentage of hands-on contact during compressions. Differences between subject groups were not found to be statistically significant, so groups were combined (n = 36) for analysis of CPR compression adequacy. Compression depth was deeper under shoulder pads than over (P = 0.02), with mean depths of 36.50 and 31.50 mm, respectively. No significant difference was found with compression rate or chest wall recoil. Chest compression depth is significantly decreased when performed over shoulder pads, while there is no apparent effect on rate or chest wall recoil. Although the clinical outcomes from our observed 15% difference in compression depth are uncertain, chest compression under the pads significantly increases the depth of compressions and more closely approaches American Heart Association guidelines for chest compression depth in cardiac arrest.
González-Otero, Digna M; de Gauna, Sofía Ruiz; Ruiz, Jesus; Rivero, Raquel; Gutierrez, J J; Saiz, Purificación; Russell, James K
2018-04-20
Out-of-hospital cardiac arrest is common in public locations, including public transportation sites. Feedback devices are increasingly being used to improve chest-compression quality. However, their performance during public transportation has not been studied yet. To test two CPR feedback devices representative of the current technologies (accelerometer and electromag- netic-field) in a long-distance train. Volunteers applied compressions on a manikin during the train route using both feedback devices. Depth and rate measurements computed by the devices were compared to the gold-standard values. Sixty-four 4-min records were acquired. The accelerometer-based device provided visual help in all experiments. Median absolute errors in depth and rate were 2.4 mm and 1.3 compressions per minute (cpm) during conventional speed, and 2.5 mm and 1.2 cpm during high speed. The electromagnetic-field-based device never provided CPR feedback; alert messages were shown instead. However, measurements were stored in its internal memory. Absolute errors for depth and rate were 2.6 mm and 0.7 cpm during conventional speed, and 2.6 mm and 0.7 cpm during high speed. Both devices were accurate despite the accelerations and the electromagnetic interferences induced by the train. However, the electromagnetic-field-based device would require modifications to avoid excessive alerts impeding feedback.
Kim, Jong Won; Park, Sang O; Lee, Kyeong Ryong; Hong, Dae Young; Baek, Kwang Je; Lee, Young Hwan; Lee, Jeong Hun; Choi, Pil Cho
2016-08-01
This study compared endotracheal intubation (ETI) performance during cardiopulmonary resuscitation (CPR) between direct laryngoscopy (DL) and video laryngoscopy (VL) (GlideScope(®)) by experienced intubators (>50 successful ETIs). This was a prospective randomized controlled study conducted in an emergency department between 2011 and 2013. Intubators who used DL or VL were randomly allocated to ETI during CPR. Data were collected from recorded video clips and rhythm sheets. The success, speed, complications, and chest compressions interruption were compared between the two devices. Total 140 ETIs by experienced intubators using DL (n=69) and VL (n=71) were analysed. There were no significant differences between DL and VL in the ETI success rate (92.8% vs. 95.8%; p=0.490), first-attempt success rate (87.0% vs. 94.4%; p=0.204), and median time to complete ETI (51 [36-67] vs. 42 [34-62]s; p=0.143). In both groups, oesophageal intubation and dental injuries seldom occurred. However, longer chest compressions interruption occurred using DL (4.0 [1.0-11.0]s) compared with VL (0.0 [0.0-1.0]s) and frequent serious no-flow (interruption>10s) occurred with DL (18/69 [26.1%]) compared with VL (0/71) (p<0.001). For highly experienced intubators (>80 successful ETIs), frequent serious no-flow occurred in DL (14/55 [25.5%] vs. 0/57 in VL). The ETI success, speed and complications during CPR did not differ significantly between the two devices for experienced intubators. However, the VL was superior in terms of completion of ETI without chest compression interruptions. Clinical Research Information Service (CRIS) in South Korea KCT0000849. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Münster, Tobias; Stosch, Christoph; Hindrichs, Nina; Franklin, Jeremy; Matthes, Jan
2016-01-01
Introduction: The external chest compression is a very important skill required to maintain a minimum of circulation during cardiac arrest until further medical procedures can be taken. Peyton’s 4-Steps-Approach is one method of skill training, the four steps being: Demonstration, Deconstruction, Comprehension and Execution. Based on CPR skill training, this method is widely, allegedly predominantly used, although there are insufficient studies on Peyton’s 4-Steps-Approach for skill training in CPR in comparison with other methods of skill training. In our study, we compared the medium- term effects on learning external chest compression with a CPR training device in three different groups: PEY (Peyton’s 4-Steps-Approach), PMOD (Peyton’s 4-Steps-Approach without Step 3) and STDM, the standard model, according to the widely spread method “see one, do one” (this is equal to Peyton’s step 1 and 3). Material and Methods: This prospective and randomised pilot study took place during the summer semester of 2009 at the SkillsLab and Simulation Centre of the University of Cologne (Kölner interprofessionelles Skills Lab und Simulationszentrum - KISS). The subjects were medical students (2nd and 3rd semester). They volunteered for the study and were randomised in three parallel groups, each receiving one of the teaching methods mentioned above. One week and 5/6 months after the intervention, an objective, structured single assessment was taken. Compression rate, compression depth, correct compressions, and the sum of correct checklist items were recorded. Additionally, we compared cumulative percentages between the groups based on the correct implementation of the resuscitation guidelines during that time. Results: The examined sample consisted of 134 subjects (68% female; age 22±4; PEY: n=62; PMOD: n=31; STDM: n=41). There was no difference between the groups concerning age, gender, pre-existing experience in CPR or time of last CPR course. The only significant difference between the groups was the mean compression rate (bpm): Group 1 (PEY) with 99±17 bpm, Group 2 (PMOD) with 101±16 bpm and Group 3 (STDM) with 90±16 bpm (p=0,007 for Group 3 vs. Group 1 and Group 3 vs. Group 2, Mann-Whitney- U-Test). We observed no significant differences between the groups after the second assessment. Conclusion: Our study showed that there are no essential differences in external chest compression during CPR performed by medical students dependent on the teaching method (Peyton vs. “Non-Peyton”) implemented with regard to the medium-term effects. The absence of benefits could possibly be due to the simplicity of external chest compression. PMID:27579360
2005-10-25
Chest compression , Ventilation 2P251107 256Page 2 1. Introduction During the initial stages of cardiopulmonary resuscitation ( CPR ), ventilation is...a metronome to facilitate chest compression timing. Twenty-eight nurses alternated performing 4 minutes of CPR using the BVM or Impact 730 to deliver... Chest compression and ventilation rates during cardiopulmonary resuscitation : the effects of audible tone guidance. Academic Emergency Medicine
Hirose, Tomoya; Iwami, Taku; Ogura, Hiroshi; Matsumoto, Hisatake; Sakai, Tomohiko; Yamamoto, Kouji; Mano, Toshiaki; Fujino, Yuji; Shimazu, Takeshi
2014-05-10
The 2010 Consensus on Science and Treatment Recommendations Statement recommended that short video/computer self-instruction courses, with minimal or no instructor coaching, combined with hands-on practice can be considered an effective alternative to instructor-led basic life support courses. The purpose of this study was to examine the effectiveness of a simplified cardiopulmonary resuscitation (CPR) training program for non-medical staff working at a university hospital. Before and immediately after a 45-min CPR training program consisting of instruction on chest compression and automated external defibrillator (AED) use with a personal training manikin, CPR skills were automatically recorded and evaluated. Participants' attitudes towards CPR were evaluated by a questionnaire survey. From September 2011 through March 2013, 161 participants attended the program. We evaluated chest compression technique in 109 of these participants. The number of chest compressions delivered after the program versus that before was significantly greater (110.8 ± 13.0/min vs 94.2 ± 27.4/min, p < 0.0001), interruption of chest compressions was significantly shorter (0.05 ± 0.34 sec/30 sec vs 0.89 ± 3.52 sec/30 sec, p < 0.05), mean depth of chest compressions was significantly greater (57.6 ± 6.8 mm vs 52.2 ± 9.4 mm, p < 0.0001), and the proportion of incomplete chest compressions of <5 cm among all chest compressions was significantly decreased (8.9 ± 23.2% vs 38.6 ± 42.9%, p < 0.0001). Of the 159 participants who responded to the questionnaire survey after the program, the proportion of participants who answered 'I can check for a response,' 'I can perform chest compressions,' and 'I can absolutely or I think I can use an AED' increased versus that before the program (81.8% vs 19.5%, 77.4% vs 10.1%, 84.3% vs 23.3%, respectively). A 45-min simplified CPR training program on chest compression and AED use improved CPR quality and the attitude towards CPR and AED use of non-medical staff of a university hospital.
Finite element comparison of human and Hybrid III responses in a frontal impact.
Danelson, Kerry A; Golman, Adam J; Kemper, Andrew R; Gayzik, F Scott; Clay Gabler, H; Duma, Stefan M; Stitzel, Joel D
2015-12-01
The improvement of finite element (FE) Human Body Models (HBMs) has made them valuable tools for investigating restraint interactions compared to anthropomorphic test devices (ATDs). The objective of this study was to evaluate the effect of various combinations of safety restraint systems on the sensitivity of thoracic injury criteria using matched ATD and Human Body Model (HBM) simulations at two crash severities. A total of seven (7) variables were investigated: 3-point belt with two (2) load limits, frontal airbag, knee bolster airbag, a buckle pretensioner, and two (2) delta-v's - 40kph and 50kph. Twenty four (24) simulations were conducted for the Hybrid III ATD FE model and repeated with a validated HBM for 48 total simulations. Metrics tested in these conditions included sternum deflection, chest acceleration, chest excursion, Viscous Criteria (V*C) criteria, pelvis acceleration, pelvis excursion, and femur forces. Additionally, chest band deflection and rib strain distribution were measured in the HBM for additional restraint condition discrimination. The addition of a frontal airbag had the largest effect on the occupant chest metrics with an increase in chest compression and acceleration but a decrease in excursion. While the THUMS and Hybrid III occupants demonstrated the same trend in the chest compression measurements, there were conflicting results in the V*C, acceleration, and displacement metrics. Similarly, the knee bolster airbag had the largest effect on the pelvis with a decrease in acceleration and excursion. With a knee bolster airbag the simulated occupants gave conflicting results, the THUMS had a decrease in femur force and the ATD had an increase. Preferential use of dummies or HBM's is not debated; however, this study highlights the ability of HBM metrics to capture additional chest response metrics. Copyright © 2015 Elsevier Ltd. All rights reserved.
Liu, Yuanshan; Huang, Zitong; Li, Heng; Zheng, Guanghui; Ling, Qin; Tang, Wanchun; Yang, Zhengfei
2018-03-06
We investigated the effects of a cardiopulmonary resuscitation (CPR) feedback/prompt device on the quality of chest compression (CC) during hands-only CPR following the 2015 AHA guidelines. A total of 124 laypersons were randomly assigned into three groups. The first (n=42) followed the 2010 guidelines, the second (n=42) followed the 2015 guidelines with no feedback/prompt device, the third (n=40) followed the 2015 guidelines with a feedback/prompt device (2015F). Participants underwent manual CPR training and took a written basic life support examination, then required to perform 2min of hands-only CPR monitored by a CPR feedback/prompt device. The quality of CPR was quantified as the percentage of correct CCs (mean CC depth and rate, complete recoil and chest compression fraction (CCF)) per 20s, as recorded by the CPR feedback/prompt device. Significantly higher correct ratios of CC, CC depth, and rate were achieved in the 2010 group in each minute vs the 2015 group. The greater mean CC depth and rate were observed in the 2015F group vs the 2015 group. The correct ratio of CC was significantly higher in the 2015F group vs the 2015 group. CCF was also significantly higher in the 2015F group vs the 2015 group in the last 20s of CPR. It is difficult for a large percentage of laypersons to achieve the targets of CC depth and rate following the 2015 AHA guidelines. CPR feedback/prompt devices significantly improve the quality of hands-only CPR performance by laypersons following the standards of the 2015 AHA guidelines. Copyright © 2017. Published by Elsevier Inc.
Chest compression rate feedback based on transthoracic impedance.
González-Otero, Digna M; Ruiz de Gauna, Sofía; Ruiz, Jesus; Daya, Mohamud R; Wik, Lars; Russell, James K; Kramer-Johansen, Jo; Eftestøl, Trygve; Alonso, Erik; Ayala, Unai
2015-08-01
Quality of cardiopulmonary resuscitation (CPR) is an important determinant of survival from cardiac arrest. The use of feedback devices is encouraged by current resuscitation guidelines as it helps rescuers to improve quality of CPR performance. To determine the feasibility of a generic algorithm for feedback related to chest compression (CC) rate using the transthoracic impedance (TTI) signal recorded through the defibrillation pads. We analysed 180 episodes collected equally from three different emergency services, each one using a unique defibrillator model. The new algorithm computed the CC-rate every 2s by analysing the TTI signal in the frequency domain. The obtained CC-rate values were compared with the gold standard, computed using the compression force or the ECG and TTI signals when the force was not recorded. The accuracy of the CC-rate, the proportion of alarms of inadequate CC-rate, chest compression fraction (CCF) and the mean CC-rate per episode were calculated. Intervals with CCs were detected with a mean sensitivity and a mean positive predictive value per episode of 96.3% and 97.0%, respectively. Estimated CC-rate had an error below 10% in 95.8% of the time. Mean percentage of accurate alarms per episode was 98.2%. No statistical differences were found between the gold standard and the estimated values for any of the computed metrics. We developed an accurate algorithm to calculate and provide feedback on CC-rate using the TTI signal. This could be integrated into automated external defibrillators and help improve the quality of CPR in basic-life-support settings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Traumatic Pancreatitis: A Rare Complication of Cardiopulmonary Resuscitation.
Aziz, Muhammad
2017-08-17
An elderly gentleman was successfully revived after undergoing cardiopulmonary resuscitation (CPR) for cardiac arrest. Post CPR, the patient developed acute pancreatitis which was likely complication of inappropriately delivered chest compressions which caused further complications and resulted in the death of the patient. This case underlines the importance of quality chest compressions that includes correct placement of hands by the operator giving chest compressions to avoid lethal injuries to the receiver.
Yang, Euiseok; Jeong, WonJoon; Lee, JunWan; Kim, SeungWhan
2014-11-01
Hemothorax is not an uncommon cardiopulmonary resuscitation(CPR)–related complication. But hemothorax related to azygos vein injury (AVI) is a rare condition following blunt chest trauma, with no report of CPR-related AVI in the literature. We present a case of azygosve in rupture in a middle-aged woman after repeated chest compression during 1 hour of CPR. She eventually presented with massive hemothorax due to azygos vein rupture diagnosed by computed tomography (CT). When faced with a patient with massive hemothorax after chest compression, azygos vein rupture should be considered as a complication.
Wang, Juan; Tang, Ce; Zhang, Lei; Gong, Yushun; Yin, Changlin; Li, Yongqin
2015-07-01
The question of whether the placement of the dominant hand against the sternum could improve the quality of manual chest compressions remains controversial. In the present study, we evaluated the influence of dominant vs nondominant hand positioning on the quality of conventional cardiopulmonary resuscitation (CPR) during prolonged basic life support (BLS) by rescuers who performed optimal and suboptimal compressions. Six months after completing a standard BLS training course, 101 medical students were instructed to perform adult single-rescuer BLS for 8 minutes on a manikin with a randomized hand position. Twenty-four hours later, the students placed the opposite hand in contact with the sternum while performing CPR. Those with an average compression depth of less than 50 mm were considered suboptimal. Participants who had performed suboptimal compressions were significantly shorter (170.2 ± 6.8 vs 174.0 ± 5.6 cm, P = .008) and lighter (58.9 ± 7.6 vs 66.9 ± 9.6 kg, P < .001) than those who performed optimal compressions. No significant differences in CPR quality were observed between dominant and nondominant hand placements for these who had an average compression depth of greater than 50 mm. However, both the compression depth (49.7 ± 4.2 vs 46.5 ± 4.1 mm, P = .003) and proportion of chest compressions with an appropriate depth (47.6% ± 27.8% vs 28.0% ± 23.4%, P = .006) were remarkably higher when compressing the chest with the dominant hand against the sternum for those who performed suboptimal CPR. Chest compression quality significantly improved when the dominant hand was placed against the sternum for those who performed suboptimal compressions during conventional CPR. Copyright © 2015 Elsevier Inc. All rights reserved.
Effect of data compression on diagnostic accuracy in digital hand and chest radiography
NASA Astrophysics Data System (ADS)
Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita
1992-05-01
Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.
2014-01-01
Background The 2010 Consensus on Science and Treatment Recommendations Statement recommended that short video/computer self-instruction courses, with minimal or no instructor coaching, combined with hands-on practice can be considered an effective alternative to instructor-led basic life support courses. The purpose of this study was to examine the effectiveness of a simplified cardiopulmonary resuscitation (CPR) training program for non-medical staff working at a university hospital. Methods Before and immediately after a 45-min CPR training program consisting of instruction on chest compression and automated external defibrillator (AED) use with a personal training manikin, CPR skills were automatically recorded and evaluated. Participants’ attitudes towards CPR were evaluated by a questionnaire survey. Results From September 2011 through March 2013, 161 participants attended the program. We evaluated chest compression technique in 109 of these participants. The number of chest compressions delivered after the program versus that before was significantly greater (110.8 ± 13.0/min vs 94.2 ± 27.4/min, p < 0.0001), interruption of chest compressions was significantly shorter (0.05 ± 0.34 sec/30 sec vs 0.89 ± 3.52 sec/30 sec, p < 0.05), mean depth of chest compressions was significantly greater (57.6 ± 6.8 mm vs 52.2 ± 9.4 mm, p < 0.0001), and the proportion of incomplete chest compressions of <5 cm among all chest compressions was significantly decreased (8.9 ± 23.2% vs 38.6 ± 42.9%, p < 0.0001). Of the 159 participants who responded to the questionnaire survey after the program, the proportion of participants who answered ‘I can check for a response,’ ‘I can perform chest compressions,’ and ‘I can absolutely or I think I can use an AED’ increased versus that before the program (81.8% vs 19.5%, 77.4% vs 10.1%, 84.3% vs 23.3%, respectively). Conclusions A 45-min simplified CPR training program on chest compression and AED use improved CPR quality and the attitude towards CPR and AED use of non-medical staff of a university hospital. PMID:24887037
Walcott, Gregory P; Melnick, Sharon B; Walker, Robert G; Banville, Isabelle; Chapman, Fred W; Killingsworth, Cheryl R; Ideker, Raymond E
2009-04-01
Pauses during chest compressions are thought to have a detrimental effect on resuscitation outcome. The Guidelines 2005 have recently eliminated the post-defibrillation pause. Previous animal studies have shown that multiple pauses of increasing duration decrease resuscitation success. We investigated the effect of varying the characteristics of a single pause near defibrillation on resuscitation outcome. Part A: 48 swine were anesthetized, fibrillated for 7min and randomized. Chest compressions were initiated for 90s followed by defibrillation and then resumption of chest compressions. Four groups were studied-G2000: 40s pause beginning 20s before, and ending 20s after defibrillation, A1: a 20s pause just before defibrillation, A2: a 20s pause ending 30s prior to defibrillation, and group A3: a 10s pause ending 30s prior to defibrillation. Part B: 12 swine (Group B) were studied with a protocol identical to Part A but with no pause in chest compressions. Primary endpoint was survival to 4h. The survival rate was significantly higher for groups A1, A2, A3, and B (5/12, 7/12, 5/12, and 5/12 survived) than for the G2000 group (0/12, p<0.05). Survival did not differ significantly among groups A1, A2, A3, and B. These results suggest that the Guidelines 2005 recommendation to omit the post-shock pulse check and immediately resume chest compressions may be an important resuscitation protocol change. However, these results also suggest that clinical maneuvers further altering a single pre-shock chest compression pause provide no additional benefit.
Walcott, Gregory P.; Melnick, Sharon B.; Walker, Robert G.; Banville, Isabelle; Chapman, Fred W.; Killingsworth, Cheryl R.; Ideker, Raymond E.
2014-01-01
Background Pauses during chest compressions are thought to have a detrimental effect on resuscitation outcome. The Guidelines 2005 have recently eliminated the post-defibrillation pause. Previous animal studies have shown that multiple pauses of increasing duration decrease resuscitation success. We investigated the effect of varying the characteristics of a single pause near defibrillation on resuscitation outcome. Methods Part A: 48 swine were anesthetized, fibrillated for 7 min and randomized. Chest compressions were initiated for 90 s followed by defibrillation and then resumption of chest compressions. Four groups were studied—G2000: 40 s pause beginning 20 s before, and ending 20 s after defibrillation, A1: a 20 s pause just before defibrillation, A2: a 20 s pause ending 30 s prior to defibrillation, and group A3: a 10 s pause ending 30 s prior to defibrillation. Part B: 12 swine (Group B) were studied with a protocol identical to Part A but with no pause in chest compressions. Primary endpoint was survival to 4 h. Results The survival rate was significantly higher for groups A1, A2, A3, and B (5/12, 7/12, 5/12, and 5/12 survived) than for the G2000 group (0/12, p < 0.05). Survival did not differ significantly among groups A1, A2, A3, and B. Conclusions These results suggest that the Guidelines 2005 recommendation to omit the post-shock pulse check and immediately resume chest compressions may be an important resuscitation protocol change. However, these results also suggest that clinical maneuvers further altering a single pre-shock chest compression pause provide no additional benefit. PMID:19185411
Perkins, Gavin D; Davies, Robin P; Soar, Jasmeet; Thickett, David R
2007-04-01
Rapid defibrillation is the most effective strategy for establishing return of spontaneous circulation following cardiac arrest due to ventricular fibrillation. The aim of this study is to measure the delay due to of charging the defibrillator during chest compression in an attempt to reduce the duration of the pre-shock pause in between cessation of chest compressions and shock delivery as advocated by the American Heart Association (AHA) guidelines compared to charging the defibrillator immediately following rhythm analysis without resuming chest compressions as recommended by the European Resuscitation Council (ERC). This was a randomised controlled cross over trial comparing pre-shock pause times when defibrillation was performed on a manikin according to the AHA and ERC guidelines using paddles and hands free defibrillation systems. The pre-shock pause between cessation of chest compression and shock delivery was significantly different between techniques (Friedman test, P<0.0001). ERC paddles technique had the greatest pre-shock pause (7.4 s [6.7-11.2]) followed by ERC hands free (7.0 s [6.5-8.5]) and AHA paddles (1.6 s [1.1-2.3]). AHA hands free took the least amount of time (1.5 s [0.8-1.5]). Extrapolating these data to older defibrillators with longer charge times saw pre-shock pause intervals of 9 s (Codemaster XL) and 12 s (Lifepak 20) with the ERC approach. This study demonstrated clinically significant delays to defibrillation by analysing and charging the defibrillator without performing concurrent chest compressions. In a simulated scenario, charging the defibrillator whilst performing chest compressions was perceived as safe and significantly reduced the pre-shock pause between cessation of chest compression and shock delivery.
NASA Astrophysics Data System (ADS)
Kandori, Akihiko; Sano, Yuko; Zhang, Yuhua; Tsuji, Toshio
2015-12-01
This paper describes a new method for calculating chest compression depth and a simple chest-compression gauge for validating the accuracy of the method. The chest-compression gauge has two plates incorporating two magnetic coils, a spring, and an accelerometer. The coils are located at both ends of the spring, and the accelerometer is set on the bottom plate. Waveforms obtained using the magnetic coils (hereafter, "magnetic waveforms"), which are proportional to compression-force waveforms and the acceleration waveforms were measured at the same time. The weight factor expressing the relationship between the second derivatives of the magnetic waveforms and the measured acceleration waveforms was calculated. An estimated-compression-displacement (depth) waveform was obtained by multiplying the weight factor and the magnetic waveforms. Displacements of two large springs (with similar spring constants) within a thorax and displacements of a cardiopulmonary resuscitation training manikin were measured using the gauge to validate the accuracy of the calculated waveform. A laser-displacement detection system was used to compare the real displacement waveform and the estimated waveform. Intraclass correlation coefficients (ICCs) between the real displacement using the laser system and the estimated displacement waveforms were calculated. The estimated displacement error of the compression depth was within 2 mm (<1 standard deviation). All ICCs (two springs and a manikin) were above 0.85 (0.99 in the case of one of the springs). The developed simple chest-compression gauge, based on a new calculation method, provides an accurate compression depth (estimation error < 2 mm).
Partiprajak, Suphamas; Thongpo, Pichaya
2016-01-01
This study explored the retention of basic life support knowledge, self-efficacy, and chest compression performance among Thai nursing students at a university in Thailand. A one-group, pre-test and post-test design time series was used. Participants were 30 nursing students undertaking basic life support training as a care provider. Repeated measure analysis of variance was used to test the retention of knowledge and self-efficacy between pre-test, immediate post-test, and re-test after 3 months. A Wilcoxon signed-rank test was used to compare the difference in chest compression performance two times. Basic life support knowledge was measured using the Basic Life Support Standard Test for Cognitive Knowledge. Self-efficacy was measured using the Basic Life Support Self-Efficacy Questionnaire. Chest compression performance was evaluated using a data printout from Resusci Anne and Laerdal skillmeter within two cycles. The training had an immediate significant effect on the knowledge, self-efficacy, and skill of chest compression; however, the knowledge and self-efficacy significantly declined after post-training for 3 months. Chest compression performance after training for 3 months was positively retaining compared to the first post-test but was not significant. Therefore, a retraining program to maintain knowledge and self-efficacy for a longer period of time should be established after post-training for 3 months. Copyright © 2015 Elsevier Ltd. All rights reserved.
Park, Sang O; Hong, Chong Kun; Shin, Dong Hyuk; Lee, Jun Ho; Hwang, Seong Youn
2013-08-01
Untrained laypersons should perform compression-only cardiopulmonary resuscitation (COCPR) under a dispatcher's guidance, but the quality of the chest compressions may be suboptimal. We hypothesised that providing metronome sounds via a phone speaker may improve the quality of chest compressions during dispatcher-assisted COCPR (DA-COCPR). Untrained laypersons were allocated to either the metronome sound-guided group (MG), who performed DA-COCPR with metronome sounds (110 ticks/min), or the control group (CG), who performed conventional DA-COCPR. The participants of each group performed DA-COCPR for 4 min using a manikin with Skill-Reporter, and the data regarding chest compression quality were collected. The data from 33 cases of DA-COCPR in the MG and 34 cases in the CG were compared. The MG showed a faster compression rate than the CG (111.9 vs 96.7/min; p=0.018). A significantly higher proportion of subjects in the MG performed the DA-COCPR with an accurate chest compression rate (100-120/min) compared with the subjects in the CG (32/33 (97.0%) vs 5/34 (14.7%); p<0.0001). The mean compression depth was not different between the MG and the CG (45.9 vs 46.8 mm; p=0.692). However, a higher proportion of subjects in the MG performed shallow compressions (compression depth <38 mm) compared with subjects in the CG (median % was 69.2 vs 15.7; p=0.035). Metronome sound guidance during DA-COCPR for the untrained bystanders improved the chest compression rates, but was associated more with shallow compressions than the conventional DA-COCPR in a manikin model.
Tracheal intubation using Macintosh and 2 video laryngoscopes with and without chest compressions.
Kim, Young-Min; Kim, Ji-Hoon; Kang, Hyung-Goo; Chung, Hyun Soo; Yim, Hyeon-Woo; Jeong, Seung-Hee
2011-07-01
The aim of the study was to compare the time taken for intubation (TTI) using the Macintosh and 2 video laryngoscopes (VLs) (GlideScope [GVL]; Saturn Biomedical System, Burnaby, British Columbia, Canada, and Airway Scope [AWS]; Pentax, Tokyo, Japan) with and without chest compressions by experienced intubators in a mannequin model. This was a randomized crossover study. Twenty-two experienced physicians who have limited experience in the VLs participated in the study. The TTI using 3 laryngoscopes with and without compressions were compared. Median TTI difference between 2 conditions was only significant in the AWS (1.64 seconds; P = .01). There were no significant differences in the TTI between the Macintosh and the GVL or the AWS during compressions. In a mannequin model, the Macintosh or the GVL was not affected by chest compressions. The TTI using the AWS was delayed by compressions but not clinically significant. Considering the lack of experience, 2 VLs may be useful adjuncts for intubation by experienced intubators during chest compressions. Copyright © 2011 Elsevier Inc. All rights reserved.
Wollborn, Jakob; Ruetten, Eva; Schlueter, Bjoern; Haberstroh, Joerg; Goebel, Ulrich; Schick, Martin A
2018-01-22
Standardized modeling of cardiac arrest and cardiopulmonary resuscitation (CPR) is crucial to evaluate new treatment options. Experimental porcine models are ideal, closely mimicking human-like physiology. However, anteroposterior chest diameter differs significantly, being larger in pigs and thus poses a challenge to achieve adequate perfusion pressures and consequently hemodynamics during CPR, which are commonly achieved during human resuscitation. The aim was to prove that standardized resuscitation is feasible and renders adequate hemodynamics and perfusion in pigs, using a specifically designed resuscitation board for a pneumatic chest compression device. A "porcine-fit" resuscitation board was designed for our experiments to optimally use a pneumatic compression device (LUCAS® II, Physio-Control Inc.), which is widely employed in emergency medicine and ideal in an experimental setting due to its high standardization. Asphyxial cardiac arrest was induced in 10 German hybrid landrace pigs and cardiopulmonary resuscitation was performed according to ERC/AHA 2015 guidelines with mechanical chest compressions. Hemodynamics were measured in the carotid and pulmonary artery. Furthermore, arterial blood gas was drawn to assess oxygenation and tissue perfusion. The custom-designed resuscitation board in combination with the LUCAS® device demonstrated highly sufficient performance regarding hemodynamics during CPR (mean arterial blood pressure, MAP 46 ± 1 mmHg and mean pulmonary artery pressure, mPAP of 36 ± 1 mmHg over the course of CPR). MAP returned to baseline values at 2 h after ROSC (80 ± 4 mmHg), requiring moderate doses of vasopressors. Furthermore, stroke volume and contractility were analyzed using pulse contour analysis (106 ± 3 ml and 1097 ± 22 mmHg/s during CPR). Blood gas analysis revealed CPR-typical changes, normalizing in the due course. Thermodilution parameters did not show persistent intravascular volume shift. Standardized cardiopulmonary resuscitation is feasible in a porcine model, achieving adequate hemodynamics and consecutive tissue perfusion of consistent quality. Copyright © 2018 Elsevier Inc. All rights reserved.
Abelairas-Gómez, Cristian; Rodríguez-Núñez, Antonio; Vilas-Pintos, Elisardo; Prieto Saborit, José Antonio; Barcala-Furelos, Roberto
2015-06-01
To describe the quality of chest compressions performed by secondary-school students trained with a realtime audiovisual feedback system. The learners were 167 students aged 12 to 15 years who had no prior experience with cardiopulmonary resuscitation (CPR). They received an hour of instruction in CPR theory and practice and then took a 2-minute test, performing hands-only CPR on a child mannequin (Prestan Professional Child Manikin). Lights built into the mannequin gave learners feedback about how many compressions they had achieved and clicking sounds told them when compressions were deep enough. All the learners were able to maintain a steady enough rhythm of compressions and reached at least 80% of the targeted compression depth. Fewer correct compressions were done in the second minute than in the first (P=.016). Real-time audiovisual feedback helps schoolchildren aged 12 to 15 years to achieve quality chest compressions on a mannequin.
Janata, Andreas; Weihs, Wolfgang; Schratter, Alexandra; Bayegan, Keywan; Holzer, Michael; Frossard, Martin; Sipos, Wolfgang; Springler, Gregor; Schmidt, Peter; Sterz, Fritz; Losert, Udo M; Laggner, Anton N; Kochanek, Patrick M; Behringer, Wilhelm
2010-08-01
The induction of deep cerebral hypothermia via ice-cold saline aortic flush during prolonged ventricular fibrillation cardiac arrest, followed by hypothermic stasis and delayed resuscitation (emergency preservation and resuscitation), improved neurologic outcome after cardiac arrest in pigs, as compared to conventional resuscitation. We hypothesized that emergency preservation and resuscitation with chest compressions would further improve outcome in the same model. Prospective experimental study. University research laboratory. : Twenty-four female, large, white breed pigs (27-37 kg). Fifteen minutes of ventricular fibrillation cardiac arrest were followed by 20 mins of resuscitation with chest compressions (control, n = 8), deep cerebral hypothermia via 200 mL/kg 4 degrees C saline aortic flush and hypothermic stasis (emergency preservation and resuscitation, n = 8), and emergency preservation and resuscitation combined with chest compressions (emergency preservation and resuscitation plus chest compressions, n = 8). At 35 mins after cardiac arrest, cardiopulmonary bypass was initiated, followed by defibrillation. Mild hypothermia was continued for 20 hrs. Pigs were evaluated after 9 days using a neurologic deficit (neurologic deficit score: 100% = brain dead; 0%-10% = normal) and an overall performance category score (overall performance category score: 1 = normal; 2 = slightly handicapped; 3 = severely handicapped; 4 = comatose; 5 = dead/brain dead). Brain temperature decreased from 38.5 degrees C to 15.3 degrees C +/- 3.3 degrees C in the emergency preservation and resuscitation group, and to 11.3 degrees C +/- 1.2 degrees C in the emergency preservation and resuscitation plus chest compressions group. In the control group, restoration of spontaneous circulation was achieved in four out of eight pigs, and one survived to 9 days. In the emergency preservation and resuscitation group, restoration of spontaneous circulation was achieved in seven out of eight pigs and five survived; in the emergency preservation and resuscitation plus chest compressions group, all had restoration of spontaneous circulation and seven survived (restoration of spontaneous circulation, p = .08). Neurologic outcome for (median and interquartile range) the control group included overall performance category score of 3, neurologic deficit score of 45%; for the emergency preservation and resuscitation group, overall performance category score was 3 (2-5) and neurologic deficit score was 45% (36; 50) and in the emergency preservation and resuscitation plus chest compressions group, overall performance category score was 2 (1-3) and neurologic deficit score was 13% (5; 21) (overall performance category score, p = .04; neurologic deficit score emergency preservation and resuscitation vs. emergency preservation and resuscitation plus chest compressions, p = .003). Emergency preservation and resuscitation by deep cerebral hypothermia combined with chest compressions during prolonged cardiac arrest in pigs are feasible and improve neurologic outcome.
Liu, Shawn; Vaillancourt, Christian; Kasaboski, Ann; Taljaard, Monica
2016-11-01
This study sought to measure bystander fatigue and cardiopulmonary resuscitation (CPR) quality after five minutes of CPR using the continuous chest compression (CCC) versus the 30:2 chest compression to ventilation method in older lay persons, a population most likely to perform CPR on cardiac arrest victims. This randomized crossover trial took place at three tertiary care hospitals and a seniors' center. Participants were aged ≥55 years without significant physical limitations (frailty score ≤3/7). They completed two 5-minute CPR sessions (using 30:2 and CCC) on manikins; sessions were separated by a rest period. We used concealed block randomization to determine CPR method order. Metronome feedback maintained a compression rate of 100/minute. We measured heart rate (HR), mean arterial pressure (MAP), and Borg Exertion Scale. CPR quality measures included total number of compressions and number of adequate compressions (depth ≥5 cm). Sixty-three participants were enrolled: mean age 70.8 years, female 66.7%, past CPR training 60.3%. Bystander fatigue was similar between CPR methods: mean difference in HR -0.59 (95% CI -3.51-2.33), MAP 1.64 (95% CI -0.23-3.50), and Borg 0.46 (95% CI 0.07-0.84). Compared to 30:2, participants using CCC performed more chest compressions (480.0 v. 376.3, mean difference 107.7; p<0.0001) and more adequate chest compressions (381.5 v. 324.9, mean difference. 62.0; p=0.0001), although good compressions/minute declined significantly faster with the CCC method (p=0.0002). CPR quality decreased significantly faster when performing CCC compared to 30:2. However, performing CCC produced more adequate compressions overall with a similar level of fatigue compared to the 30:2 method.
Saraçoğlu, Ayten; Bezen, Olgaç; Şengül, Türker; Uğur, Egin Hüsnü; Şener, Sibel; Yüzer, Fisun
2015-08-01
Interruption of chest compressions should be minimized because of its negative effects on survival. This randomized, controlled, cross-over study aimed to analyze the effectiveness of Macintosh, Miller, McCoy and McGrath laryngoscopes during with or without chest compressions in the scope of a simulated cardiopulmonary resuscitation scenario. The time required for successful tracheal intubation, number of attempts, dental trauma severity and the need for optimization manoeuvres were recorded during cardiopulmonary resuscitation with and without chest compressions. The experience with computer games during the last 10 years were asked to the participants and recorded. McCoy laryngoscope yielded the shortest time for successful tracheal intubation both in the presence of and without chest compressions. During the use of McCoy laryngoscopes, fewer tracheal intubation attempts, lower incidence of dental trauma and lower visual analogue scale scores on the ease of intubation were recorded. Participants who are experienced computer game players using Macintosh, McCoy and McGrath achieved successful tracheal intubation in a significantly shorter time during resuscitation without chest compressions. Dental trauma incidence and number of tracheal intubation attempts did not show any significant difference between the four laryngoscopes being related to the rate of playing computer games. McGrath video laryngoscopes do not appear to have advantages over direct laryngoscopes for securing a smooth and successful tracheal intubation during rhythmic chest compressions. We believe that as McCoy laryngoscope provided tracheal intubation in a shorter time and with fewer attempts, this laryngoscope may increase the success rate of resuscitation.
The effects of music on the cardiac resuscitation education of nursing students.
Tastan, Sevinc; Ayhan, Hatice; Unver, Vesile; Cinar, Fatma Ilknur; Kose, Gulsah; Basak, Tulay; Cinar, Orhan; Iyigun, Emine
2017-03-01
The purpose of this study is to examine the effects of music on the appropriate performance of the rate and depth of chest compression for nursing students. This randomized controlled study was conducted in the School of Nursing in Turkey between November 2014 and January 2015. The study's participants were second-year nursing school students with no previous formal cardiac resuscitation training (n=77). Participants were randomly assigned to one of two groups: an intervention group with music and a control group without music. During practical training, the intervention group performed chest compressions with music. The outcomes of this study were collected twice. The first evaluation was conducted one day after CPR education, and the second evaluation was conducted six weeks after the initial training. The first evaluation shows that the participants in the intervention group had an average rate of 107.33±7.29 chest compressions per minute, whereas the rate for the control group was 121.47±12.91. The second evaluation shows that the rates of chest compression for the intervention and control groups were 106.24±8.72 and 100.71±9.54, respectively. The results of this study show that a musical piece enables students to remember the ideal rhythm for chest compression. Performing chest compression with music can easily be integrated into CPR education because it does not require additional technology and is cheap. Copyright © 2016 Elsevier Ltd. All rights reserved.
Nasiri, Ebrahim; Nasiri, Reza
2014-01-01
Context: mask fixation in the lateral position is difficult during CPR. Aim: the aim of this study is to compare the lateral CPR for the use of bag-valve mask by single paramedic rescuer as well as over-the-head CPR on the chest compression and ventilation on the manikin. Settings and Design: Mazandaran University of Medical Sciences. The design of this study was a randomized cross-over trial. Methods: participants learned a standardized theoretical introduction CPR according to the 2010 guidelines. The total number of chest compressions per two minutes was measured. Total number of correct and wrong ventilation per two minutes was evaluated. Statistical Analysis: we used Wilcoxon signed-rank test to analyze the non-normally distributed data in dependence groups A. P-value of more than 0.05 was considered to show statistical significance. Results: there were 100 participants (45 women and 55 men) who participated in the study from September to March, 2011. The compression and ventilation rate in lateral CPR was lower than OTH CPR. Around 51% of participants had correct chest compression rate more than 90 beats per minute in lateral CPR and 65% of them had equal or more than ten correct ventilations per minute. Conclusions: in conclusion, this study confirmed that in a simulated CPR model over-the-head position CPR led to a better BLS than the lateral position CPR by a single paramedic student with a BVM device. We also concluded that by this new BVM fixation method on the face of the patients in the lateral position CPR can be a good alternative over-the-head mask fixation by a single trained rescuer. PMID:24665237
Hsieh, Ting-Chang; Wolfe, Heather; Sutton, Robert; Myers, Sage; Nadkarni, Vinay; Donoghue, Aaron
2015-08-01
To describe chest compression (CC) rate, depth, and leaning during pediatric cardiopulmonary resuscitation (CPR) as measured by two simultaneous methods, and to assess the accuracy and reliability of video review in measuring CC quality. Resuscitations in a pediatric emergency department are videorecorded for quality improvement. Patients aged 8-18 years receiving CPR under videorecording were eligible for inclusion. CPR was recorded by a pressure/accelerometer feedback device and tabulated in 30-s epochs of uninterrupted CC. Investigators reviewed videorecorded CPR and measured rate, depth, and release by observation. Raters categorized epochs as 'meeting criteria' if 80% of CCs in an epoch were done with appropriate depth (>45 mm) and/or release (<2.5 kg leaning). Comparison between device measurement and video was made by Spearman's ρ for rate and by κ statistic for depth and release. Interrater reliability for depth and release was measured by κ statistic. Five patients underwent videorecorded CPR using the feedback device. 97 30-s epochs of CCs were analyzed. CCs met criteria for rate in 74/97 (76%) of epochs; depth in 38/97 (39%); release in 82/97 (84%). Agreement between video and feedback device for rate was good (ρ = 0.77); agreement was poor for depth and release (κ 0.04-0.41). Interrater reliability for depth and release measured by video was poor (κ 0.04-0.49). Video review measured CC rate accurately; depth and release were not reliably or accurately assessed by video. Future research should focus on the optimal combination of methods for measuring CPR quality. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Hamrick, Jennifer L; Hamrick, Justin T; Lee, Jennifer K; Lee, Benjamin H; Koehler, Raymond C; Shaffner, Donald H
2014-04-14
End-tidal carbon dioxide (ETCO2) correlates with systemic blood flow and resuscitation rate during cardiopulmonary resuscitation (CPR) and may potentially direct chest compression performance. We compared ETCO2-directed chest compressions with chest compressions optimized to pediatric basic life support guidelines in an infant swine model to determine the effect on rate of return of spontaneous circulation (ROSC). Forty 2-kg piglets underwent general anesthesia, tracheostomy, placement of vascular catheters, ventricular fibrillation, and 90 seconds of no-flow before receiving 10 or 12 minutes of pediatric basic life support. In the optimized group, chest compressions were optimized by marker, video, and verbal feedback to obtain American Heart Association-recommended depth and rate. In the ETCO2-directed group, compression depth, rate, and hand position were modified to obtain a maximal ETCO2 without video or verbal feedback. After the interval of pediatric basic life support, external defibrillation and intravenous epinephrine were administered for another 10 minutes of CPR or until ROSC. Mean ETCO2 at 10 minutes of CPR was 22.7±7.8 mm Hg in the optimized group (n=20) and 28.5±7.0 mm Hg in the ETCO2-directed group (n=20; P=0.02). Despite higher ETCO2 and mean arterial pressure in the latter group, ROSC rates were similar: 13 of 20 (65%; optimized) and 14 of 20 (70%; ETCO2 directed). The best predictor of ROSC was systemic perfusion pressure. Defibrillation attempts, epinephrine doses required, and CPR-related injuries were similar between groups. The use of ETCO2-directed chest compressions is a novel guided approach to resuscitation that can be as effective as standard CPR optimized with marker, video, and verbal feedback.
Cardiopulmonary Resuscitation in Lunar and Martian Gravity Fields
NASA Technical Reports Server (NTRS)
Sarkar, Subhajit
2004-01-01
Cardiopulmonary resuscitation is required training for all astronauts. No studies thus far have investigated how chest compressions may be affected in lunar and Martian gravities. Therefore a theoretical quantitative study was performed. The maximum downward force an unrestrained person can apply is mg N (g(sub Earth) = 9.78 ms(sup -2), g(sub moon) = 1.63 ms(sup -2), g(sub Mars) = 3.69 ms(sup -2). Tsitlik et a1 (Critical Care Medicine, 1983) described the human sternal elastic force-displacement relationship (compliance) by: F = betaD(sub s) + gammaD(sub s)(sup 2) (beta = 54.9 plus or minus 29.4 Ncm(sup -1) and gamma = 10.8 plus or minus 4.1 Ncm(sup -2)). Maximum forces in the 3 gravitational fields produced by 76 kg (US population mean), 41 kg and 93 kg (masses derived from the limits for astronaut height), produced solutions for compression depth using Tsitlik equations for chests of: mean compliance (beta = 54.9, gamma = 10.8), low compliance (beta = 84.3, gamma = 14.9) and high compliance (beta = 25.5, gamma = 6.7). The mass for minimum adequate adult compression, 3.8 cm (AHA guidelines), was also calculated. 76 kg compresses the mean compliance chest by: Earth, 6.1 cm, Mars, 3.2 cm, Moon, 1.7 cm. In lunar gravity, the high compliance chest is compressed only 3.2 cm by 93 kg, 120 kg being required for 3.8 cm. In Martian gravity, on the mean chest, 93 kg compresses 3.6 cm; 99 kg is required for 3.8 cm. On Mars, the high compliance chest is compressed 4.8 cm with 76 kg, 5.5 cm with 93 kg, with 52 kg required for 3.8 cm.
[Resuscitation - Basic Life Support in adults and application of automatic external defibrillators].
Bohn, Andreas; Seewald, Stephan; Wnent, Jan
2016-03-01
Witnesses of a sudden cardiac arrest play a key-role in resuscitation. Lay-persons should therefore be trained to recognize that a collapsed person who is not breathing at all or breathing normally might suffer from cardiac arrest. Information of professional emergency medical staff by lay-persons and their initiation of cardio-pulmonary-resuscitation-measures are of great importance for cardiac-arrest victims. Ambulance-dispatchers have to support lay-rescuers via telephone. This support includes the localisation of the nearest Automatic External Defibrillator (AED). Presentation of agonal breathing or convulsions due to brain-hypoxia need to be recognized as potential early signs of cardiac arrest. In any case of cardiac arrest chest-compressions need to be started. There is insufficiant data to recommend "chest-compression-only"-CPR as being equally sufficient as cardio-pulmonary-resuscitation including ventilation. Rescuers trained in ventilation should therefore combine compressions and ventilations at a 30:2-ratio. Movement of the chest is being used as a sign of sufficient ventilation. High-quality chest-compressions of at least 5 cm of depth, not exceeding 6 cm, are recommended at a ratio of 100-120 chest conpressions/min. Interruption of chest-compression should be avoided. At busy public places AED should be available to enable lay-rescuers to apply early defibrillation. © Georg Thieme Verlag Stuttgart · New York.
Suzuki, Kodai; Inoue, Shigeaki; Morita, Seiji; Watanabe, Nobuo; Shintani, Ayumi; Inokuchi, Sadaki; Ogura, Shinji
2016-01-01
Although emergency resuscitative thoracotomy is performed as a salvage maneuver for critical blunt trauma patients, evidence supporting superior effectiveness of emergency resuscitative thoracotomy compared to conventional closed-chest compressions remains insufficient. The objective of this study was to investigate whether emergency resuscitative thoracotomy at the emergency department or in the operating room was associated with favourable outcomes after blunt trauma and to compare its effectiveness with that of closed-chest compressions. This was a retrospective nationwide cohort study. Data were obtained from the Japan Trauma Data Bank for the period between 2004 and 2012. The primary and secondary outcomes were patient survival rates 24 h and 28 d after emergency department arrival. Statistical analyses were performed using multivariable generalized mixed-effects regression analysis. We adjusted for the effects of different hospitals by introducing random intercepts in regression analysis to account for the differential quality of emergency resuscitative thoracotomy at hospitals where patients in cardiac arrest were treated. Sensitivity analyses were performed using propensity score matching. In total, 1,377 consecutive, critical blunt trauma patients who received cardiopulmonary resuscitation in the emergency department or operating room were included in the study. Of these patients, 484 (35.1%) underwent emergency resuscitative thoracotomy and 893 (64.9%) received closed-chest compressions. Compared to closed-chest compressions, emergency resuscitative thoracotomy was associated with lower survival rate 24 h after emergency department arrival (4.5% vs. 17.5%, respectively, P < 0.001) and 28 d after arrival (1.2% vs. 6.0%, respectively, P < 0.001). Multivariable generalized mixed-effects regression analysis with and without a propensity score-matched dataset revealed that the odds ratio for an unfavorable survival rate after 24 h was lower for emergency resuscitative thoracotomy than for closed-chest compressions (P < 0.001). Emergency resuscitative thoracotomy was independently associated with decreased odds of a favorable survival rate compared to closed-chest compressions.
Nikandish, Reza; Shahbazi, Sharbanoo; Golabi, Sedigheh; Beygi, Najimeh
2008-02-01
Previous research has suggested improved quality of chest compressions when the dominant hand was in contact with the sternum. However, the study was in health care professionals and during conventional chest compression-ventilation CPR. The aim of this study was to test the hypothesis, in null form, that the quality of external chest compressions (ECC) in novice rescuers during 5min of uninterrupted chest compression CPR (UCC-CPR) is independent of the hand in contact with the sternum. Confirmation of the hypothesis would allow the use of either hand by the novice rescuers during UCC-CPR. Fifty-nine first year public heath students participated in this randomised double-blind crossover study. After completion of a standard adult BLS course, they performed single rescuer adult UCC-CPR for 5 min on a recording Resusci Anne. One week later they changed the hand of contact with the sternum while performing ECC. The quality of ECC was recorded by the skill meter for the dominant and non-dominant hand during 5 min ECC. The total number of correct chest compressions in the dominant hand group (DH), mean 183+/-152, was not statistically different from the non-dominant hand group (NH), mean 152+/-135 (P=0.09). The number of ECC with inadequate depth in the DH group, mean 197+/-174 and NH group, mean 196+/-173 were comparable (P=0.1). The incidence of ECC exceeding the recommended depth in the DH group, mean 51+/-110 and NH group, mean 32+/-75 were comparable (P=0.1). Although there is a trend to increased incidence of correct chest compressions with positioning the dominant hand in contact with the sternum, it does not reach statistical significance during UCC-CPR by the novice rescuers for 5 min.
Use of a Metronome in Cardiopulmonary Resuscitation: A Simulation Study.
Zimmerman, Elise; Cohen, Naiomi; Maniaci, Vincenzo; Pena, Barbara; Lozano, Juan Manuel; Linares, Marc
2015-11-01
Determine whether the use of a metronome improves chest compression rate and depth during cardiopulmonary resuscitation (CPR) on a pediatric manikin. A prospective, simulation-based, crossover, randomized controlled trial was conducted. Participants included pediatric residents, fellows, nurses, and medical students who were randomly assigned to perform chest compressions on a pediatric manikin with and without an audible metronome. Each participant performed 2 rounds of 2 minutes of chest compressions separated by a 15-minute break. A total of 155 participants performed 2 rounds of chest compressions (74 with the metronome on during the first round and 81 with the metronome on during the second round of CPR). There was a significant improvement in the mean percentage of compressions delivered within an adequate rate (90-100 compressions per minute) with the metronome on compared with off (72% vs 50%; mean difference [MD] 22%; 95% confidence interval [CI], 15% to 29%). No significant difference was noted in the mean percentage of compressions within acceptable depth (38-51 mm) (72% vs 70%; MD 2%; 95% CI, -2% to 6%). The metronome had a larger effect among medical students (73% vs 55%; MD 18%; 95% CI, 8% to 28%) and pediatric residents and fellows (84% vs 48%; MD 37%; 95% CI, 27% to 46%) but not among pediatric nurses (46% vs 48%; MD -3%; 95% CI, -19% to 14%). The rate of chest compressions during CPR can be optimized by the use of a metronome. These findings will help medical professionals comply with the American Heart Association guidelines. Copyright © 2015 by the American Academy of Pediatrics.
Gohier, Francis; Dellimore, Kiran; Scheffer, Cornie
2013-01-01
The quality of cardiopulmonary resuscitation (CPR) is often inconsistent and frequently fails to meet recommended guidelines. One promising approach to address this problem is for clinicians to use an active feedback device during CPR. However, one major deficiency of existing feedback systems is that they fail to account for the displacement of the back support surface during chest compression (CC), which can be important when CPR is performed on a soft surface. In this study we present the development of a real-time CPR feedback system based on an algorithm which uses force and dual-accelerometer measurements to provide accurate estimation of the CC depth on a soft surface, without assuming full chest decompression. Based on adult CPR manikin tests it was found that the accuracy of the estimated CC depth for a dual accelerometer feedback system is significantly better (7.3% vs. 24.4%) than for a single accelerometer system on soft back support surfaces, in the absence or presence of a backboard. In conclusion, the algorithm used was found to be suitable for a real-time, dual accelerometer CPR feedback application since it yielded reasonable accuracy in terms of CC depth estimation, even when used on a soft back support surface.
Clinical utility of wavelet compression for resolution-enhanced chest radiography
NASA Astrophysics Data System (ADS)
Andriole, Katherine P.; Hovanes, Michael E.; Rowberg, Alan H.
2000-05-01
This study evaluates the usefulness of wavelet compression for resolution-enhanced storage phosphor chest radiographs in the detection of subtle interstitial disease, pneumothorax and other abnormalities. A wavelet compression technique, MrSIDTM (LizardTech, Inc., Seattle, WA), is implemented which compresses the images from their original 2,000 by 2,000 (2K) matrix size, and then decompresses the image data for display at optimal resolution by matching the spatial frequency characteristics of image objects using a 4,000- square matrix. The 2K-matrix computed radiography (CR) chest images are magnified to a 4K-matrix using wavelet series expansion. The magnified images are compared with the original uncompressed 2K radiographs and with two-times magnification of the original images. Preliminary results show radiologist preference for MrSIDTM wavelet-based magnification over magnification of original data, and suggest that the compressed/decompressed images may provide an enhancement to the original. Data collection for clinical trials of 100 chest radiographs including subtle interstitial abnormalities and/or subtle pneumothoraces and normal cases, are in progress. Three experienced thoracic radiologists will view images side-by- side on calibrated softcopy workstations under controlled viewing conditions, and rank order preference tests will be performed. This technique combines image compression with image enhancement, and suggests that compressed/decompressed images can actually improve the originals.
Simplified dispatch-assisted CPR instructions outperform standard protocol.
Dias, J A; Brown, T B; Saini, D; Shah, R C; Cofield, S S; Waterbor, J W; Funkhouser, E; Terndrup, T E
2007-01-01
Dispatch-assisted chest compressions only CPR (CC-CPR) has gained widespread acceptance, and recent research suggests that increasing the proportion of compression time during CPR may increase survival from out-of-hospital cardiac arrest. We created a simplified CC-CPR protocol to reduce time to start chest compressions and to increase the proportion of time spent delivering chest compressions. This simplified protocol was compared to a published protocol, Medical Priority Dispatch System (MPDS) Version 11.2, recommended by the National Academies of Emergency Dispatch. Subjects were randomized to the MPDS v11.2 protocol or a simplified protocol. Data was recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions for both protocols. Outcomes included chest compression rate, depth, hand position, full release, overall proportion of compressions without error, time to start of CPR and total hands-off chest time. Proportions were analyzed by Wilcoxon's Rank Sum tests and time variables with Welch ANOVA and Wilcoxon's Rank Sum test. All tests used a two-sided alpha-level of 0.05. One hundred and seventeen subjects were randomized prospectively, 58 to the standard protocol and 59 to the simplified protocol. The average age of subjects in both groups was 25 years old. For both groups, the compression rate was equivalent (104 simplified versus 94 MPDS, p = 0.13), as was the proportion with total release (1.0 simplified versus 1.0 MPDS, p = 0.09). The proportion to the correct depth was greater in the simplified protocol (0.31 versus 0.03, p < 0.01), as was the proportion of compressions done without error (0.05 versus 0.0, p = 0.16). Time to start of chest compressions and total hands-off chest time were better in the simplified protocol (start time 60.9s versus 78.6s, p < 0.0001; hands-off chest time 69 s versus 95 s, p < 0.0001). The proportion with correct hand position, however, was worse in the simplified protocol (0.35 versus 0.84, p < 0.01). The simplified protocol was as good as, or better than the MPDS v11.2 protocol in every aspect studied except hand position, and the simplified protocol resulted in significant time savings. The protocol may need modification to ensure correct hand position. Time savings and improved quality of CPR achieved by the new set of instructions could be important in strengthening critical links in the cardiac chain of survival.
Safety and Efficacy of Defibrillator Charging During Ongoing Chest Compressions: A Multicenter Study
Edelson, Dana P.; Robertson-Dick, Brian J.; Yuen, Trevor C.; Eilevstjønn, Joar; Walsh, Deborah; Bareis, Charles J.; Vanden Hoek, Terry L.; Abella, Benjamin S.
2013-01-01
BACKGROUND Pauses in chest compressions during cardiopulmonary resuscitation have been shown to correlate with poor outcomes. In an attempt to minimize these pauses, the American Heart Association recommends charging the defibrillator during chest compressions. While simulation work suggests decreased pause times using this technique, little is known about its use in clinical practice. METHODS We conducted a multicenter, retrospective study of defibrillator charging at three US academic teaching hospitals between April 2006 and April 2009. Data were abstracted from CPR-sensing defibrillator transcripts. Pre-shock pauses and total hands- off time preceding the defibrillation attempts were compared among techniques. RESULTS A total of 680 charge-cycles from 244 cardiac arrests were analyzed. The defibrillator was charged during ongoing chest compressions in 448 (65.9%) instances with wide variability across the three sites. Charging during compressions correlated with a decrease in median pre-shock pause [2.6 (IQR 1.9–3.8) vs 13.3 (IQR 8.6–19.5) s; p < 0.001] and total hands-off time in the 30 s preceding defibrillation [10.3 (IQR 6.4–13.8) vs 14.8 (IQR 11.0–19.6) s; p < 0.001]. The improvement in hands-off time was most pronounced when rescuers charged the defibrillator in anticipation of the pause, prior to any rhythm analysis. There was no difference in inappropriate shocks when charging during chest compressions (20.0 vs 20.1%; p=0.97) and there was only one instance noted of inadvertent shock administration during compressions, which went unnoticed by the compressor. CONCLUSIONS Charging during compressions is underutilized in clinical practice. The technique is associated with decreased hands-off time preceding defibrillation, with minimal risk to patients or rescuers. PMID:20807672
Russi, Christopher S.; Myers, Lucas A.; Kolb, Logan J.; Lohse, Christine M.; Hess, Erik P.; White, Roger D.
2016-01-01
Introduction American Heart Association (AHA) guidelines recommend cardiopulmonary resuscitation (CPR) chest compressions 1.5 to 2 inches (3.75–5 cm) deep at 100 to 120 per minute. Recent studies demonstrated that manual CPR by emergency medical services (EMS) personnel is substandard. We hypothesized that transport CPR quality is significantly worse than on-scene CPR quality. Methods We analyzed adult patients receiving on-scene and transport chest compressions from nine EMS sites across Minnesota and Wisconsin from May 2008 to July 2010. Two periods were analyzed: before and after visual feedback. CPR data were collected and exported with the Zoll M series monitor and a sternally placed accelerometer measuring chest compression rate and depth. We compared compression data with 2010 AHA guidelines and Zoll RescueNet Code Review software. CPR depth and rate were “above (deep),” “in,” or “below (shallow)” the target range according to AHA guidelines. We paired on-scene and transport data for each patient; paired proportions were compared with the nonparametric Wilcoxon signed rank test. Results In the pre-feedback period, we analyzed 105 of 140 paired cases (75.0%); in the post-feedback period, 35 of 140 paired cases (25.0%) were analyzed. The proportion of correct depths during on-scene compressions (median, 41.9%; interquartile range [IQR], 16.1–73.1) was higher compared to the paired transport proportion (median, 8.7%; IQR, 2.7–48.9). Proportions of on-scene median correct rates and transport median correct depths did not improve in the post-feedback period. Conclusion Transport chest compressions are significantly worse than on-scene compressions. Implementation of visual real-time feedback did not affect performance. PMID:27625733
Ko, Rachel Jia Min; Lim, Swee Han; Wu, Vivien Xi; Leong, Tak Yam; Liaw, Sok Ying
2018-01-01
INTRODUCTION Simplifying the learning of cardiopulmonary resuscitation (CPR) is advocated to improve skill acquisition and retention. A simplified CPR training programme focusing on continuous chest compression, with a simple landmark tracing technique, was introduced to laypeople. The study aimed to examine the effectiveness of the simplified CPR training in improving lay rescuers’ CPR performance as compared to standard CPR. METHODS A total of 85 laypeople (aged 21–60 years) were recruited and randomly assigned to undertake either a two-hour simplified or standard CPR training session. They were tested two months after the training on a simulated cardiac arrest scenario. Participants’ performance on the sequence of CPR steps was observed and evaluated using a validated CPR algorithm checklist. The quality of chest compression and ventilation was assessed from the recording manikins. RESULTS The simplified CPR group performed significantly better on the CPR algorithm when compared to the standard CPR group (p < 0.01). No significant difference was found between the groups in time taken to initiate CPR. However, a significantly higher number of compressions and proportion of adequate compressions was demonstrated by the simplified group than the standard group (p < 0.01). Hands-off time was significantly shorter in the simplified CPR group than in the standard CPR group (p < 0.001). CONCLUSION Simplifying the learning of CPR by focusing on continuous chest compressions, with simple hand placement for chest compression, could lead to better acquisition and retention of CPR algorithms, and better quality of chest compressions than standard CPR. PMID:29167910
Ko, Rachel Jia Min; Lim, Swee Han; Wu, Vivien Xi; Leong, Tak Yam; Liaw, Sok Ying
2018-04-01
Simplifying the learning of cardiopulmonary resuscitation (CPR) is advocated to improve skill acquisition and retention. A simplified CPR training programme focusing on continuous chest compression, with a simple landmark tracing technique, was introduced to laypeople. The study aimed to examine the effectiveness of the simplified CPR training in improving lay rescuers' CPR performance as compared to standard CPR. A total of 85 laypeople (aged 21-60 years) were recruited and randomly assigned to undertake either a two-hour simplified or standard CPR training session. They were tested two months after the training on a simulated cardiac arrest scenario. Participants' performance on the sequence of CPR steps was observed and evaluated using a validated CPR algorithm checklist. The quality of chest compression and ventilation was assessed from the recording manikins. The simplified CPR group performed significantly better on the CPR algorithm when compared to the standard CPR group (p < 0.01). No significant difference was found between the groups in time taken to initiate CPR. However, a significantly higher number of compressions and proportion of adequate compressions was demonstrated by the simplified group than the standard group (p < 0.01). Hands-off time was significantly shorter in the simplified CPR group than in the standard CPR group (p < 0.001). Simplifying the learning of CPR by focusing on continuous chest compressions, with simple hand placement for chest compression, could lead to better acquisition and retention of CPR algorithms, and better quality of chest compressions than standard CPR. Copyright: © Singapore Medical Association.
Glick, Joshua; Lehman, Erik; Terndrup, Thomas
2014-03-01
Coordination of the tasks of performing chest compressions and defibrillation can lead to communication challenges that may prolong time spent off the chest. The purpose of this study was to determine whether defibrillation provided by the provider performing chest compressions led to a decrease in peri-shock pauses as compared to defibrillation administered by a second provider, in a simulated cardiac arrest scenario. This was a randomized, controlled study measuring pauses in chest compressions for defibrillation in a simulated cardiac arrest model. We approached hospital providers with current CPR certification for participation between July, 2011 and October, 2011. Volunteers were randomized to control (facilitator-administered defibrillation) or experimental (compressor-administered defibrillation) groups. All participants completed one minute of chest compressions on a mannequin in a shockable rhythm prior to administration of defibrillation. We measured and compared pauses for defibrillation in both groups. Out of 200 total participants, we analyzed data from 197 defibrillations. Compressor-initiated defibrillation resulted in a significantly lower pre-shock hands-off time (0.57 s; 95% CI: 0.47-0.67) compared to facilitator-initiated defibrillation (1.49 s; 95% CI: 1.35-1.64). Furthermore, compressor-initiated defibrillation resulted in a significantly lower peri-shock hands-off time (2.77 s; 95% CI: 2.58-2.95) compared to facilitator-initiated defibrillation (4.25 s; 95% CI: 4.08-4.43). Assigning the responsibility for shock delivery to the provider performing compressions encourages continuous compressions throughout the charging period and decreases total time spent off the chest. However, as this was a simulation-based study, clinical implementation is necessary to further evaluate these potential benefits.
Trial of Continuous or Interrupted Chest Compressions during CPR.
Nichol, Graham; Leroux, Brian; Wang, Henry; Callaway, Clifton W; Sopko, George; Weisfeldt, Myron; Stiell, Ian; Morrison, Laurie J; Aufderheide, Tom P; Cheskes, Sheldon; Christenson, Jim; Kudenchuk, Peter; Vaillancourt, Christian; Rea, Thomas D; Idris, Ahamed H; Colella, Riccardo; Isaacs, Marshal; Straight, Ron; Stephens, Shannon; Richardson, Joe; Condle, Joe; Schmicker, Robert H; Egan, Debra; May, Susanne; Ornato, Joseph P
2015-12-03
During cardiopulmonary resuscitation (CPR) in patients with out-of-hospital cardiac arrest, the interruption of manual chest compressions for rescue breathing reduces blood flow and possibly survival. We assessed whether outcomes after continuous compressions with positive-pressure ventilation differed from those after compressions that were interrupted for ventilations at a ratio of 30 compressions to two ventilations. This cluster-randomized trial with crossover included 114 emergency medical service (EMS) agencies. Adults with non-trauma-related cardiac arrest who were treated by EMS providers received continuous chest compressions (intervention group) or interrupted chest compressions (control group). The primary outcome was the rate of survival to hospital discharge. Secondary outcomes included the modified Rankin scale score (on a scale from 0 to 6, with a score of ≤3 indicating favorable neurologic function). CPR process was measured to assess compliance. Of 23,711 patients included in the primary analysis, 12,653 were assigned to the intervention group and 11,058 to the control group. A total of 1129 of 12,613 patients with available data (9.0%) in the intervention group and 1072 of 11,035 with available data (9.7%) in the control group survived until discharge (difference, -0.7 percentage points; 95% confidence interval [CI], -1.5 to 0.1; P=0.07); 7.0% of the patients in the intervention group and 7.7% of those in the control group survived with favorable neurologic function at discharge (difference, -0.6 percentage points; 95% CI, -1.4 to 0.1, P=0.09). Hospital-free survival was significantly shorter in the intervention group than in the control group (mean difference, -0.2 days; 95% CI, -0.3 to -0.1; P=0.004). In patients with out-of-hospital cardiac arrest, continuous chest compressions during CPR performed by EMS providers did not result in significantly higher rates of survival or favorable neurologic function than did interrupted chest compressions. (Funded by the National Heart, Lung, and Blood Institute and others; ROC CCC ClinicalTrials.gov number, NCT01372748.).
Lin, Yiqun; Wan, Brandi; Belanger, Claudia; Hecker, Kent; Gilfoyle, Elaine; Davidson, Jennifer; Cheng, Adam
2017-01-01
The depth of chest compression (CC) during cardiac arrest is associated with patient survival and good neurological outcomes. Previous studies showed that mattress compression can alter the amount of CCs given with adequate depth. We aim to quantify the amount of mattress compressibility on two types of ICU mattresses and explore the effect of memory foam mattress use and a backboard on mattress compression depth and effect of feedback source on effective compression depth. The study utilizes a cross-sectional self-control study design. Participants working in the pediatric intensive care unit (PICU) performed 1 min of CC on a manikin in each of the following four conditions: (i) typical ICU mattress; (ii) typical ICU mattress with a CPR backboard; (iii) memory foam ICU mattress; and (iv) memory foam ICU mattress with a CPR backboard, using two different sources of real-time feedback: (a) external accelerometer sensor device measuring total compression depth and (b) internal light sensor measuring effective compression depth only. CPR quality was concurrently measured by these two devices. The differences of the two measures (mattress compression depth) were summarized and compared using multilevel linear regression models. Effective compression depths with different sources of feedback were compared with a multilevel linear regression model. The mean mattress compression depth varied from 24.6 to 47.7 mm, with percentage of depletion from 31.2 to 47.5%. Both use of memory foam mattress (mean difference, MD 11.7 mm, 95%CI 4.8-18.5 mm) and use of backboard (MD 11.6 mm, 95% CI 9.0-14.3 mm) significantly minimized the mattress compressibility. Use of internal light sensor as source of feedback improved effective CC depth by 7-14 mm, compared with external accelerometer sensor. Use of a memory foam mattress and CPR backboard minimizes mattress compressibility, but depletion of compression depth is still substantial. A feedback device measuring sternum-to-spine displacement can significantly improve effective compression depth on a mattress. Not applicable. This is a mannequin-based simulation research.
Football Equipment Removal Improves Chest Compression and Ventilation Efficacy.
Mihalik, Jason P; Lynall, Robert C; Fraser, Melissa A; Decoster, Laura C; De Maio, Valerie J; Patel, Amar P; Swartz, Erik E
2016-01-01
Airway access recommendations in potential catastrophic spine injury scenarios advocate for facemask removal, while keeping the helmet and shoulder pads in place for ensuing emergency transport. The anecdotal evidence to support these recommendations assumes that maintaining the helmet and shoulder pads assists inline cervical stabilization and that facial access guarantees adequate airway access. Our objective was to determine the effect of football equipment interference on performing chest compressions and delivering adequate ventilations on patient simulators. We hypothesized that conditions with more football equipment would decrease chest compression and ventilation efficacy. Thirty-two certified athletic trainers were block randomized to participate in six different compression conditions and six different ventilation conditions using human patient simulators. Data for chest compression (mean compression depth, compression rate, percentage of correctly released compressions, and percentage of adequate compressions) and ventilation (total ventilations, mean ventilation volume, and percentage of ventilations delivering adequate volume) conditions were analyzed across all conditions. The fully equipped athlete resulted in the lowest mean compression depth (F5,154 = 22.82; P < 0.001; Effect Size = 0.98) and delivery of adequate compressions (F5,154 = 15.06; P < 0.001; Effect Size = 1.09) compared to all other conditions. Bag-valve mask conditions resulted in delivery of significantly higher mean ventilation volumes compared to all 1- or 2-person pocketmask conditions (F5,150 = 40.05; P < 0.001; Effect Size = 1.47). Two-responder ventilation scenarios resulted in delivery of a greater number of total ventilations (F5,153 = 3.99; P = 0.002; Effect Size = 0.26) and percentage of adequate ventilations (F5,150 = 5.44; P < 0.001; Effect Size = 0.89) compared to one-responder scenarios. Non-chinstrap conditions permitted greater ventilation volumes (F3,28 = 35.17; P < 0.001; Effect Size = 1.78) and a greater percentage of adequate volume (F3,28 = 4.85; P = 0.008; Effect Size = 1.12) compared to conditions with the chinstrap buckled or with the chinstrap in place but not buckled. Chest compression and ventilation delivery are compromised in equipment-intense conditions when compared to conditions whereby equipment was mostly or entirely removed. Emergency medical personnel should remove the helmet and shoulder pads from all football athletes who require cardiopulmonary resuscitation, while maintaining appropriate cervical spine stabilization when injury is suspected. Further research is needed to confirm our findings supporting full equipment removal for chest compression and ventilation delivery.
Schewe, Jens-Christian; Thudium, Marcus O; Kappler, Jochen; Steinhagen, Folkert; Eichhorn, Lars; Erdfelder, Felix; Heister, Ulrich; Ellerkmann, Richard
2014-10-05
Despite recent advances in resuscitation algorithms, neurological injury after cardiac arrest due to cerebral ischemia and reperfusion is one of the reasons for poor neurological outcome. There is currently no adequate means of measuring cerebral perfusion during cardiac arrest. It was the aim of this study to investigate the feasibility of measuring near infrared spectroscopy (NIRS) as a potential surrogate parameter for cerebral perfusion in patients with out-of-hospital resuscitations in a physician-staffed emergency medical service. An emergency physician responding to out-of-hospital emergencies was equipped with a NONIN cerebral oximetry device. Cerebral oximetry values (rSO2) were continuously recorded during resuscitation and transport. Feasibility was defined as >80% of total achieved recording time in relation to intended recording time. 10 patients were prospectively enrolled. In 89.8% of total recording time, rSO2 values could be recorded (213 minutes and 20 seconds), thus meeting feasibility criteria. 3 patients experienced return of spontaneous circulation (ROSC). rSO2 during manual cardiopulmonary resuscitation (CPR) was lower in patients who did not experience ROSC compared to the 3 patients with ROSC (31.6%, ± 7.4 versus 37.2% ± 17.0). ROSC was associated with an increase in rSO2. Decrease of rSO2 indicated occurrence of re-arrest in 2 patients. In 2 patients a mechanical chest compression device was used. rSO2 values during mechanical compression were increased by 12.7% and 19.1% compared to manual compression. NIRS monitoring is feasible during resuscitation of patients with out-of-hospital cardiac arrest and can be a useful tool during resuscitation, leading to an earlier detection of ROSC and re-arrest. Higher initial rSO2 values during CPR seem to be associated with the occurrence of ROSC. The use of mechanical chest compression devices might result in higher rSO2. These findings need to be confirmed by larger studies.
Interdisciplinary ICU Cardiac Arrest Debriefing Improves Survival Outcomes
Wolfe, Heather; Zebuhr, Carleen; Topjian, Alexis A.; Nishisaki, Akira; Niles, Dana E.; Meaney, Peter A.; Boyle, Lori; Giordano, Rita T.; Davis, Daniela; Priestley, Margaret; Apkon, Michael; Berg, Robert A.; Nadkarni, Vinay M.; Sutton, Robert M.
2014-01-01
Objective In-hospital cardiac arrest is an important public health problem. High-quality resuscitation improves survival but is difficult to achieve. Our objective is to evaluate the effectiveness of a novel, interdisciplinary, postevent quantitative debriefing program to improve survival outcomes after in-hospital pediatric chest compression events. Design, Setting, and Patients Single-center prospective interventional study of children who received chest compressions between December 2008 and June 2012 in the ICU. Interventions Structured, quantitative, audiovisual, interdisciplinary debriefing of chest compression events with front-line providers. Measurements and Main Results Primary outcome was survival to hospital discharge. Secondary outcomes included survival of event (return of spontaneous circulation for ≥ 20 min) and favorable neurologic outcome. Primary resuscitation quality outcome was a composite variable, termed “excellent cardiopulmonary resuscitation,” prospectively defined as a chest compression depth ≥ 38 mm, rate ≥ 100/min, ≤ 10% of chest compressions with leaning, and a chest compression fraction > 90% during a given 30-second epoch. Quantitative data were available only for patients who are 8 years old or older. There were 119 chest compression events (60 control and 59 interventional). The intervention was associated with a trend toward improved survival to hospital discharge on both univariate analysis (52% vs 33%, p = 0.054) and after controlling for confounders (adjusted odds ratio, 2.5; 95% CI, 0.91–6.8; p = 0.075), and it significantly increased survival with favorable neurologic outcome on both univariate (50% vs 29%, p = 0.036) and multivariable analyses (adjusted odds ratio, 2.75; 95% CI, 1.01–7.5; p = 0.047). Cardiopulmonary resuscitation epochs for patients who are 8 years old or older during the debriefing period were 5.6 times more likely to meet targets of excellent cardiopulmonary resuscitation (95% CI, 2.9–10.6; p < 0.01). Conclusion Implementation of an interdisciplinary, postevent quantitative debriefing program was significantly associated with improved cardiopulmonary resuscitation quality and survival with favorable neurologic outcome. (Crit Care Med 2014; XX:00–00) PMID:24717462
Gundersen, Kenneth; Kvaløy, Jan Terje; Kramer-Johansen, Jo; Steen, Petter Andreas; Eftestøl, Trygve
2009-02-06
One of the factors that limits survival from out-of-hospital cardiac arrest is the interruption of chest compressions. During ventricular fibrillation and tachycardia the electrocardiogram reflects the probability of return of spontaneous circulation associated with defibrillation. We have used this in the current study to quantify in detail the effects of interrupting chest compressions. From an electrocardiogram database we identified all intervals without chest compressions that followed an interval with compressions, and where the patients had ventricular fibrillation or tachycardia. By calculating the mean-slope (a predictor of the return of spontaneous circulation) of the electrocardiogram for each 2-second window, and using a linear mixed-effects statistical model, we quantified the decline of mean-slope with time. Further, a mapping from mean-slope to probability of return of spontaneous circulation was obtained from a second dataset and using this we were able to estimate the expected development of the probability of return of spontaneous circulation for cases at different levels. From 911 intervals without chest compressions, 5138 analysis windows were identified. The results show that cases with the probability of return of spontaneous circulation values 0.35, 0.1 and 0.05, 3 seconds into an interval in the mean will have probability of return of spontaneous circulation values 0.26 (0.24-0.29), 0.077 (0.070-0.085) and 0.040(0.036-0.045), respectively, 27 seconds into the interval (95% confidence intervals in parenthesis). During pre-shock pauses in chest compressions mean probability of return of spontaneous circulation decreases in a steady manner for cases at all initial levels. Regardless of initial level there is a relative decrease in the probability of return of spontaneous circulation of about 23% from 3 to 27 seconds into such a pause.
Lin, Steve; Scales, Damon C
2016-06-28
High-quality cardiopulmonary resuscitation (CPR) has been shown to improve survival outcomes after cardiac arrest. The current standard in studies evaluating CPR quality is to measure CPR process measures-for example, chest compression rate, depth, and fraction. Published studies evaluating CPR feedback devices have yielded mixed results. Newer approaches that seek to optimize CPR by measuring physiological endpoints during the resuscitation may lead to individualized patient care and improved patient outcomes.
Cardiopulmonary resuscitation update.
Reynolds, Joshua C; Bond, Michael C; Shaikh, Sanober
2012-02-01
Cardiopulmonary resuscitation (CPR) is vital therapy in cardiac arrest care by lay and trained rescuers. Chest compressions are the key component of CPR. Ventilation and airway management should be secondary to high-quality and continuous chest compressions in patients receiving CPR. Only after the patient has had return of spontaneous circulation or completed a cycle of CPR with defibrillation (if appropriate) should attempts at securing an advanced airway be made. Even then, interruptions of chest compressions should be minimized to maintain cardiocerebral perfusion and increase survival. Finally, the ventilation rate should be no more than 8 to 10 breaths per minute. Copyright © 2012 Elsevier Inc. All rights reserved.
Rich, S; Wix, H L; Shapiro, E P
1981-09-01
It has been generally accepted that enhanced blood flow during closed-chest CPR is generated from compression of the heart between the sternum and the spine. To visualize the heart during closed-chest massage, we performed two-dimensional echocardiography (2DE) during resuscitation efforts in four patients who had cardiac arrest. 2DE analysis showed that (1) the LV internal dimensions did not change appreciably with chest compression; (2) the mitral and aortic valves were open simultaneously during the compression phase; (3) blood flow into the right heart, as evidenced by saline bubble contrast, occurred during the relaxation phase; and (4) compression of the right ventricle and LA occurred in varying amounts in all patients. We conclude that stroke volume from the heart during CPR does not result from compression of the LV. Rather, CPR-induced improved cardiocirculatory dynamics appear to be principally the result of changes in intrathoracic pressure created by sternal compression.
Newberry, Ryan; Redman, Ted; Ross, Elliot; Ely, Rachel; Saidler, Clayton; Arana, Allyson; Wampler, David; Miramontes, David
2018-01-01
Out-of-hospital cardiac arrest (OHCA) is a major cause of death and morbidity in the United States. Quality cardiopulmonary resuscitation (CPR) has proven to be a key factor in improving survival. The aim of our study was to investigate the outcomes of OHCA when mechanical CPR (LUCAS 2 Chest Compression System™) was utilized compared to conventional CPR. Although controlled trials have not demonstrated a survival benefit to the routine use of mechanical CPR devices, there continues to be an interest for their use in OHCA. We conducted a retrospective observational study of OHCA comparing the outcomes of mechanical and manual chest compressions in a fire department based EMS system serving a population of 1.4 million residents. Mechanical CPR devices were geographically distributed on 11 of 33 paramedic ambulances. Data were collected over a 36-month period and outcomes were dichotomized based on utilization of mechanical CPR. The primary outcome measure was survival to hospital discharge with a cerebral performance category (CPC) score of 1 or 2. This series had 3,469 OHCA reports, of which 2,999 had outcome data and met the inclusion criteria. Of these 2,236 received only manual CPR and 763 utilized a mechanical CPR device during the resuscitation. Return of spontaneous circulation (ROSC) was attained in 44% (334/763) of the mechanical CPR resuscitations and in 46% (1,020/2,236) of the standard manual CPR resuscitations (p = 0.32). Survival to hospital discharge was observed in 7% (52/763) of the mechanical CPR resuscitations and 9% (191/2,236) of the manual CPR group (p = 0.13). Discharge with a CPC score of 1 or 2 was observed in 4% (29/763) of the mechanical CPR resuscitation group and 6% (129/2,236) of the manual CPR group (p = 0.036). In our study, use of the mechanical CPR device was associated with a poor neurologic outcome at hospital discharge. However, this difference was no longer evident after logistic regression adjusting for confounding variables. Resuscitation management following institution of mechanical CPR, specifically medication and airway management, may account for the poor outcome reported. Further investigation of resuscitation management when a mechanical CPR device is utilized is necessary to optimize survival benefit.
The effect of strength training on quality of prolonged basic cardiopulmonary resuscitation.
Abelairas-Gómez, Cristian; Barcala-Furelos, Roberto; Szarpak, Łukasz; García-García, Óscar; Paz-Domínguez, Álvaro; López-García, Sergio; Rodríguez-Núñez, Antonio
2017-01-01
Providing high-quality chest compressions and rescue breaths are key elements in the effectiveness of cardio-pulmonary resuscitation. To investigate the effects of a strength training programme on the quality of prolonged basic cardiopulmonary resuscitation on a manikin. This was a quasi-experimental trial. Thirty-nine participants with prior basic life support knowledge were randomised to an experimental or control group. They then performed a test of 10 min of chest compressions and mouth-to-mouth ventilation on manikins equipped with a skill reporter tool (baseline or test 1). The experimental group participated in a four-week strength training programme focused on the muscles involved in chest compressions. Both groups were subsequently tested again (test 2). After training, the experimental group significantly increased the mean depth of compression (53.7 ± 2.3 mm vs. 49.9 ± 5.9 mm; p = 0.003) and the correct compression fraction (68.2 ± 21.0% vs. 46.4 ± 29.1%; p = 0.004). Trained subjects maintained chest compression quality over time better than the control group. The mean tidal volume delivered was higher in the experimental than in the control group (701.5 ± 187.0 mL vs. 584.8 ± 113.6 mL; p = 0.040) and above the current resuscitation guidelines. In test 2, the percentage of rescue breaths with excessive volume was higher in the experi-mental group than in the controls (31.5 ± 19.6% vs. 15.6 ± 13.0%; p = 0.007). A simple strength training programme has a significant impact on the quality of chest compressions and its maintenance over time. Additional training is needed to avoid over-ventilation of potential patients.
Two-thumb technique is superior to two-finger technique during lone rescuer infant manikin CPR.
Udassi, Sharda; Udassi, Jai P; Lamb, Melissa A; Theriaque, Douglas W; Shuster, Jonathan J; Zaritsky, Arno L; Haque, Ikram U
2010-06-01
Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as p< or =0.05. Mean % effective breaths were 90+/-18.6% in two-thumb and 88.9+/-21.1% in two-finger, p=0.65. Mean time (s) to deliver two mouth-to-mouth breaths was 7.6+/-1.6 in two-thumb and 7.0+/-1.5 in two-finger, p<0.0001. Mean delivered compressions per minute were 87+/-11 in two-thumb and 92+/-12 in two-finger, p=0.0005. Two-thumb resulted in significantly higher compression depth and compression pressure compared to the two-finger technique. Healthcare providers required 0.6s longer time to deliver two breaths during two-thumb lone rescuer infant CPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
CPR performance in the presence of audiovisual feedback or football shoulder pads.
Tanaka, Shota; Rodrigues, Wayne; Sotir, Susan; Sagisaka, Ryo; Tanaka, Hideharu
2017-01-01
The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4-6.1) cm, 114(96-131) cpm; BLS-EMS: 5.4 (4.1-6.4) cm, 112(99-131) cpm; ACLS-EMS: 6.4 (5.7-6.7) cm, 138(113-140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9-49.2)% vs 69.6 (32.3-85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0-80.7)% without feedback to 59.2 (17.3-74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the presence of FSP (median (IQR), 22.0 (7.3-36.2)% vs 71.3 (35.4-86.5)%; p=0.0002). The use of audiovisual feedback positively affects the quality of the depth of CPR. Both feedback and FSP do not alter the rate measurements. Medically trained personnel are able to deliver the desired depth regardless of the presence of FSP even though shallower chest compressions depth can be seen in CPR with FSP. A feedback device must be introduced into the athletic training settings.
CPR performance in the presence of audiovisual feedback or football shoulder pads
Tanaka, Shota; Rodrigues, Wayne; Sotir, Susan; Sagisaka, Ryo; Tanaka, Hideharu
2017-01-01
Objective The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. Methods Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. Results CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4–6.1) cm, 114(96–131) cpm; BLS-EMS: 5.4 (4.1–6.4) cm, 112(99–131) cpm; ACLS-EMS: 6.4 (5.7–6.7) cm, 138(113–140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9–49.2)% vs 69.6 (32.3–85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0–80.7)% without feedback to 59.2 (17.3–74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the presence of FSP (median (IQR), 22.0 (7.3–36.2)% vs 71.3 (35.4–86.5)%; p=0.0002). Conclusions The use of audiovisual feedback positively affects the quality of the depth of CPR. Both feedback and FSP do not alter the rate measurements. Medically trained personnel are able to deliver the desired depth regardless of the presence of FSP even though shallower chest compressions depth can be seen in CPR with FSP. A feedback device must be introduced into the athletic training settings. PMID:28761704
Gregson, Rachael Kathleen; Cole, Tim James; Skellett, Sophie; Bagkeris, Emmanouil; Welsby, Denise; Peters, Mark John
2017-05-01
To determine the effect of visual feedback on rate of chest compressions, secondarily relating the forces used. Randomised crossover trial. Tertiary teaching hospital. Fifty trained hospital staff. A thin sensor-mat placed over the manikin's chest measured rate and force. Rescuers applied compressions to the same paediatric manikin for two sessions. During one session they received visual feedback comparing their real-time rate with published guidelines. Primary: compression rate. Secondary: compression and residual forces. Rate of chest compressions (compressions per minute (compressions per minute; cpm)) varied widely (mean (SD) 111 (13), range 89-168), with a fourfold difference in variation during session 1 between those receiving and not receiving feedback (108 (5) vs 120 (20)). The interaction of session by feedback order was highly significant, indicating that this difference in mean rate between sessions was 14 cpm less (95% CI -22 to -5, p=0.002) in those given feedback first compared with those given it second. Compression force (N) varied widely (mean (SD) 306 (94); range 142-769). Those receiving feedback second (as opposed to first) used significantly lower force (adjusted mean difference -80 (95% CI -128 to -32), p=0.002). Mean residual force (18 N, SD 12, range 0-49) was unaffected by the intervention. While visual feedback restricted excessive compression rates to within the prescribed range, applied force remained widely variable. The forces required may differ with growth, but such variation treating one manikin is alarming. Feedback technologies additionally measuring force (effort) could help to standardise and define effective treatments throughout childhood. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Assessment of low-contrast detectability for compressed digital chest images
NASA Astrophysics Data System (ADS)
Cook, Larry T.; Insana, Michael F.; McFadden, Michael A.; Hall, Timothy J.; Cox, Glendon G.
1994-04-01
The ability of human observers to detect low-contrast targets in screen-film (SF) images, computed radiographic (CR) images, and compressed CR images was measured using contrast detail (CD) analysis. The results of these studies were used to design a two- alternative forced-choice (2AFC) experiment to investigate the detectability of nodules in adult chest radiographs. CD curves for a common screen-film system were compared with CR images compressed up to 125:1. Data from clinical chest exams were used to define a CD region of clinical interest that sufficiently challenged the observer. From that data, simulated lesions were introduced into 100 normal CR chest films, and forced-choice observer performance studies were performed. CR images were compressed using a full-frame discrete cosine transform (FDCT) technique, where the 2D Fourier space was divided into four areas of different quantization depending on the cumulative power spectrum (energy) of each image. The characteristic curve of the CR images was adjusted so that optical densities matched those of the SF system. The CD curves for SF and uncompressed CR systems were statistically equivalent. The slope of the CD curve for each was - 1.0 as predicted by the Rose model. There was a significant degradation in detection found for CR images compressed to 125:1. Furthermore, contrast-detail analysis demonstrated that many pulmonary nodules encountered in clinical practice are significantly above the average observer threshold for detection. We designed a 2AFC observer study using simulated 1-cm lesions introduced into normal CR chest radiographs. Detectability was reduced for all compressed CR radiographs.
Müller, Michael P; Poenicke, Cynthia; Kurth, Maxi; Richter, Torsten; Koch, Thea; Eisold, Carolin; Pfältzer, Adrian; Heller, Axel R
2015-06-21
Basic life support (BLS) guidelines focus on chest compressions with a minimal no-flow fraction (NFF), early defibrillation, and a short perishock pause. By using an automated external defibrillator (AED) lay persons are guided through the process of attaching electrodes and initiating defibrillation. It is unclear, however, to what extent the voice instructions given by the AED might influence the quality of initial resuscitation. Using a patient simulator, 8 different commercially available AEDs were evaluated within two different BLS scenarios (ventricular fibrillation vs. asystole). A BLS certified instructor acted according to the current European Resuscitation Council 2010 Guidelines and followed all of the AED voice prompts. In a second set of scenarios, the rescuer anticipated the appropriate actions and started already before the AED stopped speaking. A BLS scenario without AED served as the control. All scenarios were run three times. The time until the first chest compression was 25 ± 2 seconds without the AED and ranged from 50 ± 3 to 148 ± 13 seconds with the AED depending on the model used. The NFF was .26 ± .01 without the AED and between .37 ± .01 and .72 ± .01 when an AED was used. The perishock pause ranged from 12 ± 0 to 46 ± 0 seconds. The optimized sequence of actions reduced the NFF, which ranged now from .32 ± .01 to .41 ± .01, and the perishock pause ranging from 1 ± 1 to 19 ± 1 seconds. Voice prompts given by commercially available AED merely meet the requirements of current evidence in basic life support. Furthermore, there is a significant difference between devices with regard to time until the first chest compression, perishock pause, no-flow fraction and other objective measures of the quality of BLS. However, the BLS quality may be improved with optimized handling of the AED. Thus, rescuers should be trained on the respective AED devices, and manufacturers should expend more effort in improving user guidance to shorten the NFF and perishock pause.
A flexible pressure sensor could correctly measure the depth of chest compression on a mattress.
Minami, Kouichiro; Kokubo, Yota; Maeda, Ichinosuke; Hibino, Shingo
2016-05-01
Feedback devices are used to improve the quality of chest compression (CC). However, reports have noted that accelerometers substantially overestimate depth when cardiopulmonary resuscitation (CPR) is performed on a soft surface. Here, we determined whether a flexible pressure sensor could correctly evaluate the depth CC performed on a mannequin placed on a mattress. Chest compression was performed 100 times/min by a compression machine on the floor or a mattress, and the depth of CC was monitored using a flexible pressure sensor (Shinnosukekun) and CPRmeter(™). The depth of machine-performed CC was consistently 5cm. We compared data from the feedback sensor with the true depth of CC using dual real-time auto feedback system that incorporated an infrared camera (CPR evolution(™)). On the floor, the true depth of CC was 5.0±0.0cm (n=100), or identical to the depth of CC performed by the machine. The Shinnosukekun(™) measured a mean (±SD) CC depth of 5.0±0.1cm (n=100), and the CPRmeter(™) measured a depth of 5.0±0.2cm (n=100). On the mattress, the true depth of CC was 4.4±0.0cm (n=100). The Shinnosukekun(™) measured a mean CC depth of 4.4±0.0cm (n=100), and the CPRmeter(™) measured a depth of 4.7±0.1cm (n=100). The data of CPRmeter(™) were overestimated (P<.0001 between the true depth and the CPRmeter(™)-measured depth). The Shinnosukekun(™) could correctly measure the depth of CC on a mattress. According to our present results, the flexible pressure sensor could be a useful feedback system for CC performed on a soft surface. Copyright © 2016 Elsevier Inc. All rights reserved.
Foo, Ning-Ping; Chang, Jer-Hao; Su, Shih-Bin; Chen, Kow-Tong; Cheng, Ching-Fa; Chen, Pei-Chung
2014-01-01
Background The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). Purpose To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. Methods Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. Results The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. Conclusions The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain. PMID:25329643
Foo, Ning-Ping; Chang, Jer-Hao; Su, Shih-Bin; Chen, Kow-Tong; Cheng, Ching-Fa; Chen, Pei-Chung; Lin, Tsung-Yi; Guo, How-Ran
2014-01-01
The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain.
Bánfai, Bálint; Pandur, Attila; Pék, Emese; Csonka, Henrietta; Betlehem, József
2017-01-01
In cardiac arrest life can be saved by bystanders. Our aim was to determine at what age can schoolchildren perform correct cardiopulmonary resuscitation. 164 schoolchildren (age 7-14) were involved in the study. A basic life support training consisted of 45 minutes education in small groups (8-10 children). They were tested during a 2-minute-long continuous cardiopulmonary resuscitation scenario using the "AMBU CPR Software". Average depth of chest compression was 44.07 ± 12.6 mm. 43.9% of participants were able to do effective chest compressions. Average ventilation volume was 0.17 ± 0.31 liter. 12.8% of participants were able to ventilate effectively the patient. It was significant correlation between the chest compression depth (p<0.001) and ventilation (p<0.001) and the children's age, weight, height and BMI. Primary school children are able to learn cardiopulmonary resuscitation. The ability to do effective chest compressions and ventilation depended on the children's physical capability. Orv. Hetil., 2017, 158(4), 147-152.
Arshid, Muhammad; Lo, Tsz-Yan Milly; Reynolds, Fiona
2009-05-01
Recent evidence suggested that the quality of cardio-pulmonary resuscitation (CPR) during adult advanced life support training was suboptimal. This study aimed to assess the CPR quality of a paediatric resuscitation training programme, and to determine whether it was sufficiently addressed by the trainee team leaders during training. CPR quality of 20 consecutive resuscitation scenario training sessions was audited prospectively using a pre-designed proforma. A consultant intensivist and a senior nurse who were also Advanced Paediatric Life Support (APLS) instructors assessed the CPR quality which included ventilation frequency, chest compression rate and depth, and any unnecessary interruption in chest compressions. Team leaders' response to CPR quality and elective change of compression rescuer during training were also recorded. Airway patency was not assessed in 13 sessions while ventilation rate was too fast in 18 sessions. Target compression rate was not achieved in only 1 session. The median chest compression rate was 115 beats/min. Chest compressions were too shallow in 10 sessions and were interrupted unnecessarily in 13 sessions. More than 50% of training sessions did not have elective change of the compression rescuer. 19 team leaders failed to address CPR quality during training despite all team leaders being certified APLS providers. The quality of CPR performance was suboptimal during paediatric resuscitation training and team leaders-in-training had little awareness of this inadequacy. Detailed CPR quality assessment and feedback should be integrated into paediatric resuscitation training to ensure optimal performance in real life resuscitations.
Oh, Je Hyeok; Kim, Chan Woong; Kim, Sung Eun; Lee, Sang Jin; Lee, Dong Hoon
2014-07-01
When rescuers perform cardiopulmonary resuscitation (CPR) from a standing position, the height at which chest compressions are carried out is raised. To determine whether chest compressions delivered on a bed adjusted to rescuer's knee height are as effective as those delivered on the floor. A total of 20 fourth-year medical students participated in the study. The students performed chest compressions for 2 min each on a manikin lying on the floor (test 1) and on a manikin lying on a bed (test 2). The average compression rate (ACR) and the average compression depth (ACD) were compared between the two tests. The ACR was not significantly different between tests 1 and 2 (120.1 to 132.9 vs 115.7 to 131.2 numbers/min, 95% CI, p=0.324). The ACD was also not significantly different between tests 1 and 2 (51.2 to 56.6 vs 49.4 to 55.7 mm, 95% CI, p=0.058). The results suggest that there may be no significant differences in compression rate and depth between CPR performed on manikins placed on the floor and those placed at a rescuer's knee height. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Tracy, Mark B; Shah, Dharmesh; Hinder, Murray; Klimek, Jan; Marceau, James; Wright, Audrey
2014-05-01
To determine changes in respiratory mechanics when chest compressions are added to mask ventilation, as recommended by the International Liaison Committee on Resuscitation (ILCOR) guidelines for newborn infants. Using a Laerdal Advanced Life Support leak-free baby manikin and a 240-mL self-inflating bag, 58 neonatal staff members were randomly paired to provide mask ventilation, followed by mask ventilation with chest compressions with a 1:3 ratio, for two minutes each. A Florian respiratory function monitor was used to measure respiratory mechanics, including mask leak. The addition of chest compressions to mask ventilation led to a significant reduction in inflation rate, from 63.9 to 32.9 breaths per minute (p < 0.0001), mean airway pressure reduced from 7.6 to 4.9 cm H2 O (p < 0.001), minute ventilation reduced from 770 to 451 mL/kg/min (p < 0.0001), and there was a significant increase in paired mask leak of 6.8% (p < 0.0001). Adding chest compressions to mask ventilation, in accordance with the ILCOR guidelines, in a manikin model is associated with a significant reduction in delivered ventilation and increase in mask leak. If similar findings occur in human infants needing an escalation in resuscitation, there is a potential risk of either delay in recovery or inadequate response to resuscitation. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Wang, Juan; Zhuo, Chao-Nan; Zhang, Lei; Gong, Yu-Shun; Yin, Chang-Lin; Li, Yong-Qin
2015-01-01
The quality of chest compressions can be significantly improved after training of rescuers according to the latest national guidelines of China. However, rescuers may be unable to maintain adequate compression or ventilation throughout a response of average emergency medical services because of increased rescuer fatigue. In the present study, we evaluated the performance of cardiopulmonary resuscitation (CPR) in training of military medical university students during a prolonged basic life support (BLS). A 3-hour BLS training was given to 120 military medical university students. Six months after the training, 115 students performed single rescuer BLS on a manikin for 8 minutes. The qualities of chest compressions as well as ventilations were assessed. The average compression depth and rate were 53.7±5.3 mm and 135.1±15.7 compressions per minute respectively. The proportion of chest compressions with appropriate depth was 71.7%±28.4%. The average ventilation volume was 847.2±260.4 mL and the proportion of students with adequate ventilation was 63.5%. Compared with male students, significantly lower compression depth (46.7±4.8 vs. 54.6±4.8 mm, P<0.001) and adequate compression rate (35.5%±26.5% vs. 76.1%±25.1%, P<0.001) were observed in female students. CPR was found to be related to gender, body weight, and body mass index of students in this study. The quality of chest compressions was well maintained in male students during 8 minutes of conventional CPR but declined rapidly in female students after 2 minutes according to the latest national guidelines. Physical fitness and rescuer fatigue did not affect the quality of ventilation.
Wang, Juan; Zhuo, Chao-nan; Zhang, Lei; Gong, Yu-shun; Yin, Chang-lin; Li, Yong-qin
2015-01-01
BACKGROUND: The quality of chest compressions can be significantly improved after training of rescuers according to the latest national guidelines of China. However, rescuers may be unable to maintain adequate compression or ventilation throughout a response of average emergency medical services because of increased rescuer fatigue. In the present study, we evaluated the performance of cardiopulmonary resuscitation (CPR) in training of military medical university students during a prolonged basic life support (BLS). METHODS: A 3-hour BLS training was given to 120 military medical university students. Six months after the training, 115 students performed single rescuer BLS on a manikin for 8 minutes. The qualities of chest compressions as well as ventilations were assessed. RESULTS: The average compression depth and rate were 53.7±5.3 mm and 135.1±15.7 compressions per minute respectively. The proportion of chest compressions with appropriate depth was 71.7%±28.4%. The average ventilation volume was 847.2±260.4 mL and the proportion of students with adequate ventilation was 63.5%. Compared with male students, significantly lower compression depth (46.7±4.8 vs. 54.6±4.8 mm, P<0.001) and adequate compression rate (35.5%±26.5% vs. 76.1%±25.1%, P<0.001) were observed in female students. CONCLUSIONS: CPR was found to be related to gender, body weight, and body mass index of students in this study. The quality of chest compressions was well maintained in male students during 8 minutes of conventional CPR but declined rapidly in female students after 2 minutes according to the latest national guidelines. Physical fitness and rescuer fatigue did not affect the quality of ventilation. PMID:26401177
Semeraro, Federico; Frisoli, Antonio; Loconsole, Claudio; Bannò, Filippo; Tammaro, Gaetano; Imbriaco, Guglielmo; Marchetti, Luca; Cerchiari, Erga L
2013-04-01
Outcome after cardiac arrest is dependent on the quality of chest compressions (CC). A great number of devices have been developed to provide guidance during CPR. The present study evaluates a new CPR feedback system (Mini-VREM: Mini-Virtual Reality Enhanced Mannequin) designed to improve CC during training. Mini-VREM system consists of a Kinect(®) (Microsoft, Redmond, WA, USA) motion sensing device and specifically developed software to provide audio-visual feedback. Mini-VREM was connected to a commercially available mannequin (Laerdal Medical, Stavanger, Norway). Eighty trainees (healthcare professionals and lay people) volunteered in this randomised crossover pilot study. All subjects performed a 2 min CC trial, 1h pause and a second 2 min CC trial. The first group (FB/NFB, n=40) performed CC with Mini-VREM feedback (FB) followed by CC without feedback (NFB). The second group (NFB/FB, n=40) performed vice versa. Primary endpoints: adequate compression (compression rate between 100 and 120 min(-1) and compression depth between 50 and 60mm); compressions rate within 100-120 min(-1); compressions depth within 50-60mm. When compared to the performance without feedback, with Mini-VREM feedback compressions were more adequate (FB 35.78% vs. NFB 7.27%, p<0.001) and more compressions achieved target rate (FB 72.04% vs. 31.42%, p<0.001) and target depth (FB 47.34% vs. 24.87%, p=0.002). The participants perceived the system to be easy to use with effective feedback. The Mini-VREM system was able to improve significantly the CC performance by healthcare professionals and by lay people in a simulated CA scenario, in terms of compression rate and depth. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Chunling, Ji; Hourong, Zhou; Xiulin, Yang; Qian, Zhang; Yuhui, Yuan; Jia, Huang
2015-12-01
To study the protective effect of erythropoietin (EPO) on brain tissue with cardiac arrest-cardiopulmonary resuscitation (CA-CPR) and its mechanism. 120 male Sprague-Dawley (SD) rats were randomly divided into three groups (each n = 40), namely: sham group, routine chest compression group, and conventional chest compression + EPO group (EPO group). The rats in each group were subdivided into CA and 6, 12, 24, 48 hours after restoration of spontaneous circulation (ROSC) five subgroups (each n = 8). The model of CA was reproduced according to the Hendrickx classical asphyxia method followed by routine chest compression, and the rats in sham group only underwent anesthesia, tracheostomy intubation and venous-puncture without asphyxia and CPR. The rats in EPO group were given the routine chest compression + EPO 5 kU/kg (2 mL/kg) after CA. Blood sample was collected at different time points of intervention for the determination the content of serum S100 β protein by enzyme linked immunosorbent assay (ELISA). All the rats were sacrificed at the corresponding time points, and the hippocampus was harvested for the calculation of the number of S100 β protein positive cells, and to examine the pathological changes and their scores at 24 hours after ROSC by light microscopy. With prolongation of ROSC time, the serum levels of S100 β protein (µg/L) in the routine chose compression group and the EPO group were significantly elevated, peaking at 24 hours (compared with CA: 305.7 ± 29.2 vs. 44.4 ± 6.2 in routine chest compression group, and 276.7 ± 28.9 vs. 44.7 ± 5.6 in the EPO group, both P < 0.05), followed by a fall. The levels of S100 β protein at each time point after ROSC in EPO group were significanthy lower than those of the routine chest compression group (83.2 ± 7.5 vs. 114.3 ± 15.3 at 6 hours, 123.9 ± 20.2 vs. 184.9 ± 22.2 at 12 hours, 276.7 ± 28.9 vs. 305.7 ± 29.2 at 24 hours, 256.3 ± 26.6 vs. 283.2 ± 23.6 at 48 hours, all P < 0.05). With the prolongation of ROSC time, the S100 β protein positive cell number in brain (cells/HP) in the routine chest compression group and the EPO group was significantly increased, peaking at 24 hours (compared with CA: 14.3 ± 2.2 vs. 6.7 ± 0.7 in the routine chest compression group, 11.3 ± 1.3 vs. 6.8 ± 0.9 in the EPO group, both P < 0.05), then it began to fall. The S100 β protein positive cell number in brain at each time point after ROSC in the EPO group was significantly lower than that of the routine chest compression group (7.0 ± 0.9 vs. 7.9 ± 1.9 at 6 hours, 8.4 ± 1.1 vs. 10.2 ± 2.2 at 12 hours, 11.3 ± 1.3 vs. 14.3 ± 2.2 at 24 hours, 8.3 ± 0.8 vs. 10.8 ± 2.0 at 48 hours, all P < 0.05). Under the light microscope, a serious brain cortex injury was found after reproduction of the model, and the degree of injury was reduced after EPO intervention. The pathological score at 24 hours after ROSC in EPO group was lower than that of routine chest compression group (3.83 ± 0.73 vs. 4.17 ± 0.75, P < 0.05). The S100 β protein level in serum and brain tissue was increased early in asphyxia CA-CPR rats. EPO intervention can reduce the expression of S100 protein and reduce the degree of brain injury.
You, Je Sung; Chung, Sung Phil; Chang, Chul Ho; Park, Incheol; Lee, Hye Sun; Kim, SeungHo; Lee, Hahn Shick
2013-08-01
In real cardiopulmonary resuscitation (CPR), noise can arise from instructional voices and environmental sounds in places such as a battlefield and industrial and high-traffic areas. A feedback device using a flashing light was designed to overcome noise-induced stimulus saturation during CPR. This study was conducted to determine whether 'flashlight' guidance influences CPR performance in a simulated noisy setting. We recruited 30 senior medical students with no previous experience of using flashlight-guided CPR to participate in this prospective, simulation-based, crossover study. The experiment was conducted in a simulated noisy situation using a cardiac arrest model without ventilation. Noise such as patrol car and fire engine sirens was artificially generated. The flashlight guidance device emitted light pulses at the rate of 100 flashes/min. Participants also received instructions to achieve the desired rate of 100 compressions/min. CPR performances were recorded with a Resusci Anne mannequin with a computer skill-reporting system. There were significant differences between the control and flashlight groups in mean compression rate (MCR), MCR/min and visual analogue scale. However, there were no significant differences in correct compression depth, mean compression depth, correct hand position, and correctly released compression. The flashlight group constantly maintained the pace at the desired 100 compressions/min. Furthermore, the flashlight group had a tendency to keep the MCR constant, whereas the control group had a tendency to decrease it after 60 s. Flashlight-guided CPR is particularly advantageous for maintaining a desired MCR during hands-only CPR in noisy environments, where metronome pacing might not be clearly heard.
Deep-seated intramuscular lipoma penetrates the intercostal muscle
Hwang, Jinwook; Min, Byoung-Ju; Shin, Jae Seung
2015-01-01
Deep-seated intramuscular lipomas are rare, and most exhibit an infiltrating behavior. This study reports serial radiographs of a lipoma in chest wall muscles which penetrated the intercostal muscle for a 6-year period. Although this lipoma did not involve the parietal pleura, it compressed lung. To the authors’ knowledge, the present study is the first report to show the growth of a deep-seated chest wall lipoma into the thoracic cavity through serial radiographs. We consider the surgical treatment is needed before deep-seated intramuscular chest wall lipoma compress intrathoracic structures. PMID:26623127
Stecher, Frederik S; Olsen, Jan-Aage; Stickney, Ronald E; Wik, Lars
2008-12-01
There is a need to measure cardiopulmonary resuscitation (CPR) in order to document whether ambulance personnel follow CPR guidelines. Our goal was to do this using defibrillator technology based on changes in transthoracic impedance (TTI) produced by chest compressions and ventilations. 122 incidents of out-of-hospital cardiac arrest between May 2003 and February 2004 were analysed based on data recorded from defibrillators in Oslo EMS. New software was used to analyze chest compressions and ventilations based on changes in thoracic impedance between the defibrillator pads, as well as ECG and other event data. In total, 25+/-14% (varying from 76% to 3%) of the time chest compressions were not performed on patients without spontaneous circulation (NFR=No Flow Ratio). When adjusting for time spent on analysis of ECG, pulse check and defibrillation, NFR was 20+/-13% (varying from 70% to 3%). Mean compressions delivered per minute was 87+/-16 and the compression rate during active compressions was 117+/-9min(-1). Individual variation was 31-117min(-1) (mean) and 95-144min(-1) (active periods). A mean of 14+/-3ventilations/min was recorded, varying from 8 to 26min(-1). Compared with the rest of the episode, the first 5min had a significantly higher proportion of time without chest compressions; 30+/-17% (p<0.001) and significantly lower mean compression and ventilation rates; 80+/-19min(-1) and 12+/-4min(-1), respectively (p<0.001 in both cases). Core CPR values can be measured from TTI signals by using a standard defibrillator and new software. NFR was 25% (20% adjusted) with great rescuer variability.
Sullivan, Nancy J; Duval-Arnould, Jordan; Twilley, Marida; Smith, Sarah P; Aksamit, Deborah; Boone-Guercio, Pam; Jeffries, Pamela R; Hunt, Elizabeth A
2015-01-01
Traditional American Heart Association (AHA) cardiopulmonary resuscitation (CPR) curriculum focuses on teams of two performing quality chest compressions with rescuers on their knees but does not include training specific to In-Hospital Cardiac Arrests (IHCA), i.e. patient in hospital bed with large resuscitation teams and sophisticated technology available. A randomized controlled trial was conducted with the primary goal of evaluating the effectiveness and ideal frequency of in-situ training on time elapsed from call for help to; (1) initiation of chest compressions and (2) successful defibrillation in IHCA. Non-intensive care unit nurses were randomized into four groups: standard AHA training (C) and three groups that participated in 15 min in-situ IHCA training sessions every two (2M), three (3M) or six months (6M). Curriculum included specific choreography for teams to achieve immediate chest compressions, high chest compression fractions and rapid defibrillation while incorporating use of a backboard, stepstool. More frequent training was associated with decreased median (IQR) seconds to: starting compressions: [C: 33(25-40) vs. 6M: 21(15-26) vs. 3M: 14(10-20) vs. 2M: 13(9-20); p < 0.001]; and defibrillation: [C: 157(140-254) vs. 6M: 138(107-158) vs. 3M: 115(101-119) vs. 2M: 109(98-129); p < 0.001]. A composite outcome of key priorities, compressions within 20s, defibrillation within 180 s and use of a backboard, revealed improvement with more frequent training sessions: [C:5%(1/18) vs. 6M: 23%(4/17) vs. 3M: 56%(9/16) vs. 2M: 73%(11/15); p < 0.001]. Results revealed short in-situ training sessions conducted every 3 months are effective in improving timely initiation of chest compressions and defibrillation in IHCA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Brown, Todd B; Saini, Devashish; Pepper, Tracy; Mirza, Muzna; Nandigam, Hari Krishna; Kaza, Niroop; Cofield, Stacey S
2008-02-01
The quality of early bystander CPR appears important in maximizing survival. This trial tests whether explicit instructions to "put the phone down" improve the quality of bystander initiated dispatch-assisted CPR. In a randomized, double-blinded, controlled trial, subjects were randomized to a modified version of the Medical Priority Dispatch System (MPDS) version 11.2 protocol or a simplified protocol, each with or without instruction to "put the phone down" during CPR. Data were recorded from a Laerdal Resusci Anne Skillreporter manikin. A simulated emergency medical dispatcher, contacted by cell phone, delivered standardized instructions. Primary outcome measures included chest compression rate, depth, and the proportion of compressions without error, with correct hand position, adequate depth, and total release. Time was measured in two distinct ways: time required for initiation of CPR and total amount of time hands were off the chest during CPR. Proportions were analyzed by Wilcoxon rank sum tests and time variables with ANOVA. All tests used a two-sided alpha-level of 0.05. Two hundred and fifteen subjects were randomized-107 in the "put the phone down" instruction group and 108 in the group without "put the phone down" instructions. The groups were comparable across demographic and experiential variables. The additional instruction to "put the phone down" had no effect on the proportion of compressions administered without error, with the correct depth, and with the correct hand position. Likewise, "put the phone down" did not affect the average compression depth, the average compression rate, the total hands-off-chest time, or the time to initiate chest compressions. A statistically significant, yet trivial, effect was found in the proportion of compressions with total release of the chest wall. Instructions to "put the phone down" had no effect on the quality of bystander initiated dispatcher-assisted CPR in this trial.
Sigurdsson, Gardar; Yannopoulos, Demetris; McKnite, Scott H; Lurie, Keith G
2003-06-01
Recent advances in cardiopulmonary resuscitation have shed light on the importance of cardiorespiratory interactions during shock and cardiac arrest. This review focuses on recently published studies that evaluate factors that determine preload during chest compression, methods that can augment preload, and the detrimental effects of hyperventilation and interrupting chest compressions. Refilling of the ventricles, so-called ventricular preload, is diminished during cardiovascular collapse and resuscitation from cardiac arrest. In light of the potential detrimental effects and challenges of large-volume fluid resuscitations, other methods have increasing importance. During cardiac arrest, active decompression of the chest and impedance of inspiratory airflow during the recoil of the chest work by increasing negative intrathoracic pressure and, hence, increase refilling of the ventricles and increase cardiac preload, with improvement in survival. Conversely, increased frequency of ventilation has detrimental effects on coronary perfusion pressure and survival rates in cardiac arrest and severe shock. Prolonged interruption of chest compressions for delivering single-rescuer ventilation or analyzing rhythm before shock delivery is associated with decreased survival rate. Cardiorespiratory interactions are of profound importance in states of cardiovascular collapse in which increased negative intrathoracic pressure during decompression of the chest has a favorable effect and increased intrathoracic pressure with ventilation has a detrimental effect on survival rate.
Melissopoulou, Theodora; Stroumpoulis, Konstantinos; Sampanis, Michail A; Vrachnis, Nikolaos; Papadopoulos, Georgios; Chalkias, Athanasios; Xanthos, Theodoros
2014-01-01
To investigate whether nursing staff can successfully use the I-gel and the intubating laryngeal mask Fastrach (ILMA) during cardiopulmonary resuscitation. Although tracheal intubation is considered to be the optimal method for securing the airway during cardiopulmonary resuscitation, laryngoscopy requires a high level of skill. Forty five nurses inserted the I-gel and the ILMA in a manikin, with continuous and without chest compressions. Mean intubation times for the ILMA and I-gel without chest compressions were 20.60 ± 3.27 and 18.40 ± 3.26 s, respectively (p < 0.0005). ILMA proved more successful than the I-gel regardless of compressions. Continuation of compressions caused a prolongation in intubation times for both the I-gel (p < 0.0005) and the ILMA (p < 0.0005). In this mannequin study, nursing staff can successfully intubate using the I-gel and the ILMA as conduits with comparable success rates, regardless of whether chest compressions are interrupted or not. Copyright © 2014 Elsevier Inc. All rights reserved.
Compression asphyxia in upright suspended position.
Tumram, Nilesh Keshav; Ambade, Vipul Namdeorao; Dixit, Pradeep Gangadhar
2014-06-01
In compression asphyxia, the respiration is prevented by external pressure on the body. It is usually due to external force compressing the trunk due to heavy weight over chest/abdomen and is associated with internal injuries. In the present case, the victim was suspended in an upright position owing to wedging of the chest and the abdomen in the gap between 2 parallel bridges undergoing construction. There was neither any heavy weight over the body, nor was any external force applied over the trunk. Moreover, there was neither any severe blunt force injury nor any significant pathological natural disease contributing to the cause of death. The body was wedged in the gap between 2 static hard surfaces. The victim was unable to extricate himself from the position owing to impairment of cognitive responses and coordination due to influence of alcohol. The victim died as a result of "static" asphyxia due to compression of the chest and the abdomen. Compression asphyxia in upright suspended position under this circumstance is very rare and not reported previously to the best of our knowledge.
Peberdy, Mary Ann; Gluck, Jason A; Ornato, Joseph P; Bermudez, Christian A; Griffin, Russell E; Kasirajan, Vigneshwar; Kerber, Richard E; Lewis, Eldrin F; Link, Mark S; Miller, Corinne; Teuteberg, Jeffrey J; Thiagarajan, Ravi; Weiss, Robert M; O'Neil, Brian
2017-06-13
Cardiac arrest in patients on mechanical support is a new phenomenon brought about by the increased use of this therapy in patients with end-stage heart failure. This American Heart Association scientific statement highlights the recognition and treatment of cardiovascular collapse or cardiopulmonary arrest in an adult or pediatric patient who has a ventricular assist device or total artificial heart. Specific, expert consensus recommendations are provided for the role of external chest compressions in such patients. © 2017 American Heart Association, Inc.
Choi, Sung Soo; Yun, Seong-Woo; Lee, Byung Kook; Jeung, Kyung Woon; Song, Kyoung Hwan; Lee, Chang-Hee; Park, Jung Soo; Jeong, Ji Yeon; Shin, Sang Yeol
2015-03-01
To improve the quality of chest compression (CC), we developed the assistant-push method, whereby the second rescuer pushes the back of the chest compressor during CC. We investigated the effectiveness and feasibility of assistant push in achieving and maintaining the CC quality. This was a randomized crossover trial in which 41 subjects randomly performed both of standard CC (single-rescuer group) and CC with instructor-driven assistant push (assistant-push group) in different order. Each session of CC was performed for 2 minutes using a manikin. Subjects were also assigned to both roles of chest compressor and assistant and together performed CC with subject-driven assistant push. Depth of CC, compression to recoil ratio, duty cycle, and rate of incomplete recoil were quantified. The mean depth of CC (57.0 [56.0-59.0] vs 55.0 [49.5-57.5], P < .001) was significantly deeper, and the compression force (33.8 [29.3-36.4] vs 23.3 [20.4-25.3], P < .001) was stronger in the assistant-push group. The ratio of compression to recoil, duty cycle, and rate of incomplete chest recoil were comparable between the 2 groups. The CC depth in the single-rescuer group decreased significantly every 30 seconds, whereas in the assistant-push group, it was comparable at 60- and 90-second time points (P = .004). The subject assistant-push group performed CCs at a depth comparable with that of the instructor assistant-push group. The assistant-push method improved the depth of CC and attenuated its decline, eventually helping maintain adequate CC depth over time. Subjects were able to feasibly learn assistant push and performed effectively. Copyright © 2014 Elsevier Inc. All rights reserved.
Lyon, R M; Clarke, S; Gowens, P; Egan, G; Clegg, G R
2010-12-01
Out-of-hospital cardiac arrest (OHCA) is a leading cause of pre-hospital mortality. Chest compressions performed during cardiopulmonary resuscitation aim to provide adequate perfusion to the vital organs during cardiac arrest. Poor resuscitation technique and the quality of pre-hospital CPR influences outcome from OHCA. Transthoracic impedance (TTI) measurement is a useful tool in the assessment of the quality of pre-hospital resuscitation by ambulance crews but TTI telemetry has not yet been performed in the United Kingdom. We describe a pilot study to implement a data network to collect defibrillator TTI data via telemetry from ambulances. Prospective, observational pilot study over a 5-month period. Modems were fitted to 40 defibrillators on ambulances based in Edinburgh. TTI data was sent to a receiving computer after resuscitation attempts for OHCA. 58 TTI traces were transmitted during the pilot period. Compliance with the telemetry system was high. The mean ratio of chest compressions was 73% (95% CI 69-77%), the mean chest compression rate was 128 (95% CI 122-134). The mean time interval from chest compression interruption to shock delivery was 27 s (95% CI 22-32 s). Trans-thoracic impedance analysis is an effective means of recording important measures of resuscitation quality including the hands-on-the-chest time, compression rate and defibrillation interval time. TTI data transmission via telemetry is straightforward, efficient and allows resuscitation data to be captured and analysed from a large geographical area. Further research is warranted on the impact of post-resuscitation reporting on the quality of resuscitation delivered by ambulance crews. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Nakanishi, Taizo; Goto, Tadahiro; Kobuchi, Taketsune; Kimura, Tetsuya; Hayashi, Hiroyuki; Tokuda, Yasuharu
2017-12-22
To compare bystander cardiopulmonary resuscitation skills retention between conventional learning and flipped learning for first-year medical students. A post-test only control group design. A total of 108 participants were randomly assigned to either the conventional learning or flipped learning. The primary outcome measures of time to the first chest compression and the number of total chest compressions during a 2-minute test period 6 month after the training were assessed with the Mann-Whitney U test. Fifty participants (92.6%) in the conventional learning group and 45 participants (83.3%) in the flipped learning group completed the study. There were no statistically significant differences 6 months after the training in the time to the first chest compression of 33.0 seconds (interquartile range, 24.0-42.0) for the conventional learning group and 31.0 seconds (interquartile range, 25.0-41.0) for the flipped learning group (U=1171.0, p=0.73) or in the number of total chest compressions of 101.5 (interquartile range, 90.8-124.0) for the conventional learning group and 104.0 (interquartile range, 91.0-121.0) for the flipped learning group (U=1083.0, p=0.75). The 95% confidence interval of the difference between means of the number of total chest compressions 6 months after the training did not exceed a clinically important difference defined a priori. There were no significant differences between the conventional learning group and the flipped learning group in our main outcomes. Flipped learning might be comparable to conventional learning, and seems a promising approach which requires fewer resources and enables student-centered learning without compromising the acquisition of CPR skills.
Xu, Bing; Wang, Huang-Lei; Xiong, Dan; Sheng, Li-Pin; Yang, Qi-Sheng; Jiang, Shan; Xu, Peng; Chen, Zhi-Qiao; Zhao, Yan
2015-01-01
Previous studies have shown improved external chest compression (ECC) quality and delayed rescuer fatigue when the dominant hand (DH) was in contact with the sternum. However, many rescuers prefer placing the non-dominant hand (NH) in contact with the sternum during ECC. We aimed to investigate the effects of up-down hand position switch on the quality of ECC and the fatigue of rescuers during cardiopulmonary resuscitation (CPR). After completion of a review of the standard adult basic life support (BLS) course, every candidate performed 10 cycles of single adult CPR twice on an adult manikin with either a constant hand position (CH) or a switched hand position (SH) in random order at 7-day intervals. The rescuers’ general characteristics, hand positions, physiological signs, fatigue appearance and ECC qualities were recorded. Our results showed no significant differences in chest compression quality for the DH position rescuers between the CH and SH sessions (p>0.05, resp.). And also no significant differences were found for Borg score (p = 0.437) or cycle number (p = 0.127) of fatigue appearance after chest compressions between the two sessions. However, for NH position rescuers, the appearance of fatigue was delayed (p = 0.046), with a lower Borg score in the SH session (12.67 ± 2.03) compared to the CH session (13.33 ± 1.95) (p = 0.011). Moreover, the compression depth was significantly greater in the SH session (39.3 ± 7.2 mm) compared to the CH session (36.3 ± 8.1 mm) (p = 0.015). Our data suggest that the up-down hand position switch during CPR may delay the fatigue of non-dominant hand position rescuers and improve the quality of chest compressions. PMID:26267353
Toyoshima, Mitsuo; Maeoka, Yukinori; Kawahara, Hitoshi; Maegaki, Yoshihiro; Ohno, Kousaku
2006-11-01
We report 10 cases of pulmonary atelectasis diagnosed by chest computed tomography in patients with neurological or muscular disease. Atelectasis was frequently seen in hypotonic patients who could not roll over on their own. The atelectases located mostly in the dorsal bronchopulmonary segments, adjacent to the heart or diaphragm. Atelectasis diminished in two patients after they became able to roll themselves over. Gravity-related lung compression by the heart and intra-abdominal organs on persistent supine position can cause pulmonary atelectasis in patients with neurological or muscular disease who can not roll over by their own power. To confirm that the prone position reduces compression of the lungs, chest computed tomography was performed in both the supine and the prone position in three patients. Sagittal images with three-dimensional computed tomographic reconstruction revealed significant sternad displacements of the heart and caudal displacements of the dorsal portion of the diaphragm on prone position compared with supine position. The prone position, motor exercises for rolling over, and biphasic cuirass ventilation are effective in reducing gravity-related lung compression. Some patients with intellectual disabilities were also able to cooperate in chest physiotherapy. Chest physiotherapy is useful in preventing atelectasis in patients with neurological or muscular disease.
Szarpak, Łukasz; Czyżewski, Łukasz; Truszewski, Zenon; Kurowski, Andrzej; Gaszyński, Tomasz
2015-11-01
The aim of the study was to compare the intubation times and success rates of various laryngoscopes during resuscitation in pediatric emergency intubation with uninterrupted chest compression on a standardized pediatric manikin model. This was a randomized crossover study with 107 paramedic participants. We compared times to successful intubation, intubation success rates, and glottic visibility using a Cormack-Lehane grade for Macintosh, Intubrite®, Coopdech®, and Copilot® laryngoscopes. One hundred seven paramedics (mean age 31.2 ± 7.5 years) routinely involved in the management of prehospital care participated in this study. Intubation success rates (overall effectiveness), which was the primary study endpoint, were highest for the Coopdech® and CoPilot® devices (100 %) and were lowest for Intubrite® (89.7 %, p < 0.001) and Macintosh (80.4 %, p < 0.001). The secondary study endpoint, time to first effective ventilation, was achieved fastest when using the Coopdech® laryngoscope (21.6 ± 6.2 s) and was significantly slower with all other devices (Intubrite® 25.4 ± 10.5 s, p = 0.006; CoPilot® 25.6 ± 7.4 s, p = 0.007; Macintosh 29.4 ± 8.2 s, p < 0.001). We conclude that in child simulations managed by paramedics, the Coopdech® and Copilot® video laryngoscopes performed better than the standard Macintosh or Intubrite® laryngoscopes for endotracheal intubation during child chest compression.
Cardiac compression due to gastric volvulus: an unusual cause of chest pain.
Brown, Alex; Austin, David; Kanakala, Venkatesh
2017-05-22
A 42-year-old man was admitted to coronary care for assessment with severe retrosternal chest pain. Echocardiography showed significant external compression of the left atrium. A subsequent CT scan revealed him to have a large hiatus hernia, with most of his stomach herniating into his thorax causing left atrial compression and gastric volvulus. He subsequently underwent successful emergency decompression of the gastric volvulus and repair of his hiatus hernia. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Donoghue, Aaron; Hsieh, Ting-Chang; Nishisaki, Akira; Myers, Sage
2016-02-01
To describe procedural characteristics of tracheal intubation (TI) during cardiopulmonary resuscitation (CPR) in a pediatric emergency department, and to characterize interruptions in CPR associated with TI performance. Retrospective single center case series. Resuscitations in a pediatric ED are videorecorded for quality improvement. Children who underwent TI while receiving chest compressions were eligible for inclusion. Intubations done by methods other than direct laryngoscopy were excluded. Background data included patient age and training background of intubator. Data on intubation attempts (success, laryngoscopy time) and chest compressions (interruptions, duration of pauses) were collected. Between December 2012 and February 2014, 32 patients had 59 TI attempts performed during CPR. Overall first attempt success at TI was 15/32 (47%); a median of 2 attempts were made per patient (range 1 to 4). Median laryngoscopy time was 47s (range 8-115s). 32/59 (54%) TI attempts had an associated interruption in CPR; the median interruption duration was 25s (range 3-64s). TI attempts without interruption in CPR were successful in 20/32 (63%) compared to 11/27 (41%) when CPR was paused (p=0.09). Laryngoscopy time was not significantly different between TI attempts with (47±21s) and without (47±26s; p=0.2) interruptions in compressions. 25/32 (78%) of pauses exceeded 10s in duration. TI during pediatric CPR results in significant interruptions in chest compressions. Procedural outcomes were not significantly different between attempts with and without compressions paused. In children receiving CPR, TI should be performed without pausing chest compressions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Byard, Roger W; Bellis, Maria
2016-05-01
A retrospective blinded study of thyroid gland histology was undertaken in 50 infants and young children aged from 1 to 24 months. Deaths were due to (i) suffocation (N = 7), hanging (4), wedging (3), and chest and/or neck compression (4), and (ii) SIDS (20), noncervical trauma (7), organic disease, (4) and drug toxicity (1). In the asphyxia group (N = 18), thyroid gland congestion ranged from 0 to 3+ with 39% of cases (7/18) having moderate/marked congestion. In three cases, focal aggregates of red blood cells (blood islands) were observed within the intrafollicular colloid. These deaths involved chest compression, chest and/or neck compression, and crush asphyxia in a vehicle accident, and all had facial petechiae. Only 22% of the 32 control cases (7/32) had moderate/marked congestion with no blood islands being identified (p < 0.05). Blood islands within the thyroid gland may be caused by congestion associated with crushing or compression and may provide supportive evidence for this diagnosis. © 2016 American Academy of Forensic Sciences.
Resuscitator’s perceptions and time for corrective ventilation steps during neonatal resuscitation☆
Sharma, Vinay; Lakshminrusimha, Satyan; Carrion, Vivien; Mathew, Bobby
2016-01-01
Background The 2010 neonatal resuscitation program (NRP) guidelines incorporate ventilation corrective steps (using the mnemonic – MRSOPA) into the resuscitation algorithm. The perception of neonatal providers, time taken to perform these maneuvers or the effectiveness of these additional steps has not been evaluated. Methods Using two simulated clinical scenarios of varying degrees of cardiovascular compromise –perinatal asphyxia with (i) bradycardia (heart rate – 40 min−1) and (ii) cardiac arrest, 35 NRP certified providers were evaluated for preference to performing these corrective measures, the time taken for performing these steps and time to onset of chest compressions. Results The average time taken to perform ventilation corrective steps (MRSOPA) was 48.9 ± 21.4 s. Providers were less likely to perform corrective steps and proceed directly to endotracheal intubation in the scenario of cardiac arrest as compared to a state of bradycardia. Cardiac compressions were initiated significantly sooner in the scenario of cardiac arrest 89 ± 24 s as compared to severe bradycardia 122 ± 23 s, p < 0.0001. There were no differences in the time taken to initiation of chest compressions between physicians or mid-level care providers or with the level of experience of the provider. Conclusions Effective ventilation of the lungs with corrective steps using a mask is important in most cases of neonatal resuscitation. Neonatal resuscitators prefer early endotracheal intubation and initiation of chest compressions in the presence of asystolic cardiac arrest. Corrective ventilation steps can potentially postpone initiation of chest compressions and may delay return of spontaneous circulation in the presence of severe cardiovascular compromise. PMID:25796996
Totally implanted ports: the trapezius approach in practice.
Hill, Steve
Implanted ports (IPs) are an essential device for many patients who require long-term vascular access. IPs offer some advantages over other central venous access devices, such as lifestyle, body image benefits and lower infection rates. A typical implantation site for a port is the anterior chest wall. For some patients with breast cancer who have metastatic chest wall disease this site may lead to problems with the function of the device if disease spreads to the port site. One option for this patient group is to place the implanted port over the trapezius muscle. This article discusses six patients, all of whom had metastatic breast cancer with some degree of subcutaneous disease on the anterior chest wall. Three patients had received trapezius port placements and three had anterior chest wall placements. A retrospective review of the patients' medical records was undertaken from the time of insertion until removal or until the patient died. The anterior chest wall group of patients had their devices in for an average of 368 days vs 214 in the trapezius group. The total complications were higher in the anterior chest wall group (7 vs 2 in the trapezius group). Disease spread to two of the devices in the anterior chest wall group meaning the devices could no longer be used. The trapezius approach appears to be a safe and a reliable form of vascular access and may offer fewer complications than the traditional method of anterior chest wall placement when standard anterior chest wall approach is not suitable.
Zhang, Guang; Wu, Taihu; Song, Zhenxing; Wang, Haitao; Lu, Hengzhi; Wang, Yalin; Wang, Dan; Chen, Feng
2015-06-01
Chest compression (CC) is a significant emergency medical procedure for maintaining circulation during cardiac arrest. Although CC produces the necessary blood flow for patients with heart arrest, improperly deep CC will contribute significantly to the risk of chest injury. In this paper, an optimal CC closed-loop controller for a mechanical chest compressor (OCC-MCC) was developed to provide an effective trade-off between the benefit of improved blood perfusion and the risk of ribs fracture. The trade-off performance of the OCC-MCC during real automatic mechanical CCs was evaluated by comparing the OCC-MCC and the traditional mechanical CC method (TMCM) with a human circulation hardware model based on hardware simulations. A benefit factor (BF), risk factor (RF) and benefit versus risk index (BRI) were introduced in this paper for the comprehensive evaluation of risk and benefit. The OCC-MCC was developed using the LabVIEW control platform and the mechanical chest compressor (MCC) controller. PID control is also employed by MCC for effective compression depth regulation. In addition, the physiological parameters model for MCC was built based on a digital signal processor for hardware simulations. A comparison between the OCC-MCC and TMCM was then performed based on the simulation test platform which is composed of the MCC, LabVIEW control platform, physiological parameters model for MCC and the manikin. Compared with the TMCM, the OCC-MCC obtained a better trade-off and a higher BRI in seven out of a total of nine cases. With a higher mean value of cardiac output (1.35 L/min) and partial pressure of end-tidal CO2 (15.7 mmHg), the OCC-MCC obtained a larger blood flow and higher BF than TMCM (5.19 vs. 3.41) in six out of a total of nine cases. Although it is relatively difficult to maintain a stable CC depth when the chest is stiff, the OCC-MCC is still superior to the TMCM for performing safe and effective CC during CPR. The OCC-MCC is superior to the TMCM in performing safe and effective CC during CPR and can be incorporated into the current version of mechanical CC devices for high quality CPR, in both in-hospital and out-of-hospital CPR settings.
Compression asphyxia from a human pyramid.
Tumram, Nilesh Keshav; Ambade, Vipul Namdeorao; Biyabani, Naushad
2015-12-01
In compression asphyxia, respiration is stopped by external forces on the body. It is usually due to an external force compressing the trunk such as a heavy weight on the chest or abdomen and is associated with internal injuries. In present case, the victim was trapped and crushed under the falling persons from a human pyramid formation for a "Dahi Handi" festival. There was neither any severe blunt force injury nor any significant pathological natural disease contributing to the cause of death. The victim was unable to remove himself from the situation because his cognitive responses and coordination were impaired due to alcohol intake. The victim died from asphyxia due to compression of his chest and abdomen. Compression asphyxia resulting from the collapse of a human pyramid and the dynamics of its impact force in these circumstances is very rare and is not reported previously to the best of our knowledge. © The Author(s) 2015.
Calvo-Buey, J A; Calvo-Marcos, D; Marcos-Camina, R M
2016-01-01
To determine whether the use of CPRmeter(®) during the resuscitation manoeuvres, is related to a higher quality of external cardiac massage, as recommended by the International Liaison Committee on Resuscitation (ILCOR). To compare the quality obtained without the use or this, and whether there are differences related to anthropometric, demographic, professional and/or occupational factors. Experimental, open trial performed with life support simulators in a stratified random sample of 88 health workers randomly distributed between groups A (without indications of the device) and B (with them). The homogeneity of their confounding variables was compared, as well as the compressions depth and compressions rate, the proportion of completed release, and distribution of the quality massage variable (according to criteria ILCOR) between the groups. The qualitative variables were analysed with the chi-square test, and quantitative variables with the Student t-test or Mann-Whitney U-test and the association between the variable quality massage variable, and use of the device with the odds ratio. Group A: mean depth 42.1mm (standard deviation 10.1), mean rate 121.3/min (21.6), percentage of complete release 71.2% (36.9). Group B: 51.2mm (5.9) 111.9/min (6.4), 92.9% (10.1) respectively. Odds ratio for quality massage regarding the use of the device was 5.170 (95% CI; 2.060-12.977). The use of CPRmeter(®) device in simulated resuscitations is related to a higher quality of cardiac massage, improving the approach to the ILCOR recommendations, regardless of the characteristics of the participants. They were 83.8% more likely to achieve a quality massage using the device than without it. Copyright © 2015 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Brace compression for treatment of pectus carinatum.
Jung, Joonho; Chung, Sang Ho; Cho, Jin Kyoung; Park, Soo-Jin; Choi, Ho; Lee, Sungsoo
2012-12-01
Surgery has been the classical treatment of pectus carinatum (PC), though compressive orthotic braces have shown successful results in recent years. We propose a non-operative approach using a lightweight, patient-controlled dynamic chest-bracing device. Eighteen patients with PC were treated between July 2008 and June 2009. The treatment involved fitting of the brace, which was worn for at least 20 hours per day for 6 months. Their degree of satisfaction (1, no correction; 4, remarkable correction) was measured at 12 months after the initiation of the treatment. Thirteen (72.2%) patients completed the treatment (mean time, 4.9±1.4 months). In patients who completed the treatment, the mean overall satisfaction score was 3.73±0.39. The mean satisfaction score was 4, and there was no recurrence of pectus carinatum in patients who underwent the treatment for at least 6 months. Minimal recurrence of pectus carinatum after removal of the compressive brace occurred in 5 (38.5%) patients who stopped wearing the compressive brace at 4 months. Compressive bracing results in a significant improvement in PC appearance in patients with an immature skeleton. However, patient compliance and diligent follow-up appear to be paramount for the success of this method of treatment. We currently offer this approach as a first-line treatment for PC.
Fukatsu, Hiroshi; Naganawa, Shinji; Yumura, Shinnichiro
2008-04-01
This study was aimed to validate the performance of a novel image compression method using a neural network to achieve a lossless compression. The encoding consists of the following blocks: a prediction block; a residual data calculation block; a transformation and quantization block; an organization and modification block; and an entropy encoding block. The predicted image is divided into four macro-blocks using the original image for teaching; and then redivided into sixteen sub-blocks. The predicted image is compared to the original image to create the residual image. The spatial and frequency data of the residual image are compared and transformed. Chest radiography, computed tomography (CT), magnetic resonance imaging, positron emission tomography, radioisotope mammography, ultrasonography, and digital subtraction angiography images were compressed using the AIC lossless compression method; and the compression rates were calculated. The compression rates were around 15:1 for chest radiography and mammography, 12:1 for CT, and around 6:1 for other images. This method thus enables greater lossless compression than the conventional methods. This novel method should improve the efficiency of handling of the increasing volume of medical imaging data.
NASA Astrophysics Data System (ADS)
Choi, Sunghoon; Lee, Haenghwa; Lee, Donghoon; Choi, Seungyeon; Shin, Jungwook; Jang, Woojin; Seo, Chang-Woo; Kim, Hee-Joung
2017-03-01
A compressed-sensing (CS) technique has been rapidly applied in medical imaging field for retrieving volumetric data from highly under-sampled projections. Among many variant forms, CS technique based on a total-variation (TV) regularization strategy shows fairly reasonable results in cone-beam geometry. In this study, we implemented the TV-based CS image reconstruction strategy in our prototype chest digital tomosynthesis (CDT) R/F system. Due to the iterative nature of time consuming processes in solving a cost function, we took advantage of parallel computing using graphics processing units (GPU) by the compute unified device architecture (CUDA) programming to accelerate our algorithm. In order to compare the algorithmic performance of our proposed CS algorithm, conventional filtered back-projection (FBP) and simultaneous algebraic reconstruction technique (SART) reconstruction schemes were also studied. The results indicated that the CS produced better contrast-to-noise ratios (CNRs) in the physical phantom images (Teflon region-of-interest) by factors of 3.91 and 1.93 than FBP and SART images, respectively. The resulted human chest phantom images including lung nodules with different diameters also showed better visual appearance in the CS images. Our proposed GPU-accelerated CS reconstruction scheme could produce volumetric data up to 80 times than CPU programming. Total elapsed time for producing 50 coronal planes with 1024×1024 image matrix using 41 projection views were 216.74 seconds for proposed CS algorithms on our GPU programming, which could match the clinically feasible time ( 3 min). Consequently, our results demonstrated that the proposed CS method showed a potential of additional dose reduction in digital tomosynthesis with reasonable image quality in a fast time.
Minimally invasive repair of pectus carinatum and how to deal with complications
Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo
2016-01-01
While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient’s malformation. This molding is done using benders designed as part of the procedure. PMID:29078492
Minimally invasive repair of pectus carinatum and how to deal with complications.
Abramson, Horacio; Aragone, Xavier; Blanco, Javier Borbore; Ciano, Alejandro; Abramson, Leonardo
2016-01-01
While less common than pectus excavatum, pectus carinatum is also a chest wall deformity affecting males in higher proportion than women. Patient requests for a solution of this disease occur especially during the growth spurt of puberty when this malformation becomes more obvious and difficult to conceal. Those people suffering from pectus carinatum are very likely subject to behavioral changes and negative personality impacts. By compressing the protruding anterior region of the chest wall we achieve correction of the chest contour and simultaneous lateral expansion of the depressed costochondral arches. This original technique and the procedure to apply it fit within the category of minimally invasive surgery. The compression system acts in a way similar to that of orthodontic braces. Two rectangular fixation plates are fixed to the compression strut with screws. The plates have threaded holes along a groove in the central portion, and two holes at both ends used to attach them to the ribs by means of steel wire suture. The compression strut has to be modified into a convex shape to adapt it to the particular characteristics of the patient's malformation. This molding is done using benders designed as part of the procedure.
Chang, Mary P; Gent, Lana M; Sweet, Merrilee; Potts, Jerry; Ahtone, Jeral; Idris, Ahamed H
2017-07-01
The American Heart Association set goals in 2010 to train 20 million people annually in cardiopulmonary resuscitation and to double bystander response by 2020. These ambitious goals are difficult to achieve without new approaches. The main objective is to evaluate a new approach to cardiopulmonary resuscitation instruction using a self-instructional kiosk to teach Hands-Only CPR to people at a busy international airport. This is a prospective, observational study evaluating a new approach to teach Hands-Only CPR to the public from July 2013 to February 2016. The American Heart Association developed a Hands-Only CPR Kiosk for this project. We assessed the number of participants who viewed the instructional video and practiced chest compressions as well as the quality metrics of the chest compressions. In a 32-month period, there were 23478 visits to the Hands-Only CPR Kiosk and 9006 test sessions; of those practice sessions, 26.2% achieved correct chest compression rate, 60.2% achieved correct chest compression depth, and 63.5% had the correct hand position. There is noticeable public interest in learning Hands-Only CPR by using an airport kiosk and an airport is an opportune place to engage a layperson in learning Hands-Only CPR. The average quality of Hands-Only CPR by the public needs improvement and adding kiosks to other locations in the airport could reach more people and could be replicated in other major airports in the United States. Copyright © 2017 Elsevier B.V. All rights reserved.
Nitzschke, Rainer; Doehn, Christoph; Kersten, Jan F; Blanz, Julian; Kalwa, Tobias J; Scotti, Norman A; Kubitz, Jens C
2017-04-04
The present study evaluates whether the quality of advanced cardiac life support (ALS) is improved with an interactive prototype assist device. This device consists of an automated external defibrillator linked to a ventilator and provides synchronised visual and acoustic instructions for guidance through the ALS algorithm and assistance for face-mask ventilations. We compared the cardiopulmonary resuscitation (CPR) quality of emergency medical system (EMS) staff members using the study device or standard equipment in a mannequin simulation study with a prospective, controlled, randomised cross-over study design. Main outcome was the effect of the study device compared to the standard equipment and the effect of the number of prior ALS trainings of the EMS staff on the CPR quality. Data were analysed using analyses of covariance (ANCOVA) and binary logistic regression, accounting for the study design. In 106 simulations of 56 two-person rescuer teams, the mean hands-off time was 24.5% with study equipment and 23.5% with standard equipment (Difference 1.0% (95% CI: -0.4 to 2.5%); p = 0.156). With both types of equipment, the hands-off time decreased with an increasing cumulative number of previous CPR trainings (p = 0.042). The study equipment reduced the mean time until administration of adrenaline (epinephrine) by 23 s (p = 0.003) and that of amiodarone by 17 s (p = 0.016). It also increased the mean number of changes in the person doing chest compressions (0.6 per simulation; p < 0.001) and decreased the mean number of chest compressions (2.8 per minute; p = 0.022) and the mean number of ventilations (1.8 per minute; p < 0.001). The chance of administering amiodarone at the appropriate time was higher, with an odds ratio of 4.15, with the use of the study equipment CPR.com compared to the standard equipment (p = 0.004). With an increasing number of prior CPR trainings, the time intervals in the ALS algorithm until the defibrillations decreased with standard equipment but increased with the study device. EMS staff with limited training in CPR profit from guidance through the ALS algorithm by the study device. However, the study device somehow reduced the ALS quality of well-trained rescuers and thus can only be recommended for ALS provider with limited experience.
Stewart, Claire; Shoemaker, Jamie; Keller-Smith, Rachel; Edmunds, Katherine; Davis, Andrew; Tegtmeyer, Ken
2017-10-16
Pediatric code blue activations are infrequent events with a high mortality rate despite the best effort of code teams. The best method for training these code teams is debatable; however, it is clear that training is needed to assure adherence to American Heart Association (AHA) Resuscitation Guidelines and to prevent the decay that invariably occurs after Pediatric Advanced Life Support training. The objectives of this project were to train a multidisciplinary, multidepartmental code team and to measure this team's adherence to AHA guidelines during code simulation. Multidisciplinary code team training sessions were held using high-fidelity, in situ simulation. Sessions were held several times per month. Each session was filmed and reviewed for adherence to 5 AHA guidelines: chest compression rate, ventilation rate, chest compression fraction, use of a backboard, and use of a team leader. After the first study period, modifications were made to the code team including implementation of just-in-time training and alteration of the compression team. Thirty-eight sessions were completed, with 31 eligible for video analysis. During the first study period, 1 session adhered to all AHA guidelines. During the second study period, after alteration of the code team and implementation of just-in-time training, no sessions adhered to all AHA guidelines; however, there was an improvement in percentage of sessions adhering to ventilation rate and chest compression rate and an improvement in median ventilation rate. We present a method for training a large code team drawn from multiple hospital departments and a method of assessing code team performance. Despite subjective improvement in code team positioning, communication, and role completion and some improvement in ventilation rate and chest compression rate, we failed to consistently demonstrate improvement in adherence to all guidelines.
Lyon, Richard M; Crawford, Anna; Crookston, Colin; Short, Steven; Clegg, Gareth R
2015-08-01
Quality of manual cardiopulmonary resuscitation (CPR) during extrication and transport of out-of-hospital cardiac arrest victims is known to be poor. Performing manual CPR during ambulance transport poses significant risk to the attending emergency medical services crew. We sought to use pre-hospital video recording to objectively analyse the impact of introducing mechanical CPR with an extrication sheet (Autopulse, Zoll) to an advanced, second-tier cardiac arrest response team. The study was conducted prospectively using defibrillator downloads and analysis of pre-hospital video recording to measure the quality of CPR during extrication from scene and ambulance transport of the OHCA patient. Adult patients with non-traumatic OHCA were included. The interruption to manual CPR to during extrication and to deploy the mechanical CPR device was analysed. In the manual CPR group, 53 OHCA cases were analysed for quality of CPR during extrication. The median time that chest compression was interrupted to allow the patient to be carried from scene to the ambulance was 270 s (IQR 201-387 s). 119 mechanical CPR cases were analysed. The median time interruption from last manual compression to first Autopulse compression was 39 s (IQR 29-47 s). The range from last manual compression to first Autopulse compression was 14-118 s. Mechanical CPR used in combination with an extrication sheet can be effectively used to improve the quality of resuscitation during extrication and ambulance transport of the refractory OHCA patient. The time interval to deploy the mechanical CPR device can be shortened with regular simulation training. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Li, Heng; Zhang, Lei; Yang, Zhengfei; Huang, Zitong; Chen, Bihua; Li, Yongqin; Yu, Tao
2013-01-01
Objective. Untrained bystanders usually delivered suboptimal chest compression to victims who suffered from cardiac arrest in out-of-hospital settings. We therefore investigated the hemodynamics and resuscitation outcome of initial suboptimal quality of chest compressions compared to the optimal ones in a porcine model of cardiac arrest. Methods. Fourteen Yorkshire pigs weighted 30 ± 2 kg were randomized into good and poor cardiopulmonary resuscitation (CPR) groups. Ventricular fibrillation was electrically induced and untreated for 6 mins. In good CPR group, animals received high quality manual chest compressions according to the Guidelines (25% of animal's anterior-posterior thoracic diameter) during first two minutes of CPR compared with poor (70% of the optimal depth) compressions. After that, a 120-J biphasic shock was delivered. If the animal did not acquire return of spontaneous circulation, another 2 mins of CPR and shock followed. Four minutes later, both groups received optimal CPR until total 10 mins of CPR has been finished. Results. All seven animals in good CPR group were resuscitated compared with only two in poor CPR group (P < 0.05). The delayed optimal compressions which followed 4 mins of suboptimal compressions failed to increase the lower coronary perfusion pressure of five non-survival animals in poor CPR group. Conclusions. In a porcine model of prolonged cardiac arrest, even four minutes of initial poor quality of CPR compromises the hemodynamics and survival outcome. PMID:24364028
Prevalence and hemodynamic effects of leaning during CPR
Niles, Dana E.; Sutton, Robert M.; Nadkarni, Vinay M.; Glatz, Andrew; Zuercher, Mathias; Maltese, Matthew R.; Eilevstjønn, Joar; Abella, Benjamin S.; Becker, Lance B.; Berg, Robert A.
2013-01-01
Background Cardiopulmonary resuscitation (CPR) guidelines recommend complete release between chest compressions (CC). Objective Evaluate the hemodynamic effects of leaning (incomplete chest wall release) during CPR and the prevalence of leaning during CPR. Results In piglet ventricular fibrillation cardiac arrests, 10% and 20% (1.8 kg and 3.6 kg, respectively), leaning during CPR increased right atrial pressures, decreased coronary perfusion pressures, and decreased cardiac index and left ventricular myocardial blood flow by nearly 50%. In contrast, residual leaning of a 260 g accelerometer/ force feedback device did not adversely affect cardiac index or myocardial blood flow. Among 108 adult in-hospital CPR events, leaning ≥2.5 kg was demonstrable in 91% of the events and 12% of the evaluated CC. For 12 children with in-hospital CPR, 28% of CC had residual leaning ≥2.5 kg and 89% had residual leaning ≥0.5 kg. Conclusions Leaning during CPR increases intrathoracic pressure, decreases coronary perfusion pressure, and decreases cardiac output and myocardial blood flow. Leaning is common during CPR. PMID:22208173
Szarpak, Łukasz; Kurowski, Andrzej; Truszewski, Zenon; Robak, Oliver; Frass, Michael
2015-08-01
Ensuring an open airway during cardiopulmonary resuscitation is fundamental. The aim of this study was to determine the success rate of blind intubation during simulated cardiopulmonary resuscitation by untrained personnel. Four devices were compared in a simulated resuscitation scenario: ILMA (Intavent Direct Ltd, Buckinghamshire, United Kingdom), Cobra PLA (Engineered Medical Systems Inc, Indianapolis, IN), Supraglottic Airway Laryngopharyngeal Tube (SALT) (ECOLAB, St. Paul, MN), and Air-Q (Mercury Medical, Clearwater, FL). A group of 210 paramedics intubated a manikin with continuous chest compressions. The mean times to intubation were 40.46 ± 4.64, 33.96 ± 6.23, 17.2 ± 4.63, and 49.23 ± 13.19 seconds (SALT vs ILMA, Cobra PLA, and Air-Q; P < .05). The success ratios of blind intubation for the devices were 86.7%, 85.7%, 100%, and 71.4% (SALT vs ILMA, Cobra PLA, and Air-Q; P < .05). The study showed that the most efficient device with the shortest blind intubation time was the SALT device. Copyright © 2015 Elsevier Inc. All rights reserved.
Effects of depth and chest volume on cardiac function during breath-hold diving.
Marabotti, Claudio; Scalzini, Alessandro; Cialoni, Danilo; Passera, Mirko; Ripoli, Andrea; L'Abbate, Antonio; Bedini, Remo
2009-07-01
Cardiac response to breath-hold diving in human beings is primarily characterized by the reduction of both heart rate and stroke volume. By underwater Doppler-echocardiography we observed a "restrictive/constrictive" left ventricular filling pattern compatible with the idea of chest squeeze and heart compression during diving. We hypothesized that underwater re-expansion of the chest would release heart constriction and normalize cardiac function. To this aim, 10 healthy male subjects (age 34.2 +/- 10.4) were evaluated by Doppler-echocardiography during breath-hold immersion at a depth of 10 m, before and after a single maximal inspiration from a SCUBA device. During the same session, all subjects were also studied at surface (full-body immersion) and at 5-m depth in order to better characterize the relationship of echo-Doppler pattern with depth. In comparison to surface immersion, 5-m deep diving was sufficient to reduce cardiac output (P = 0.042) and increase transmitral E-peak velocity (P < 0.001). These changes remained unaltered at a 10-m depth. Chest expansion at 10 m decreased left ventricular end-systolic volume (P = 0.024) and increased left ventricular stroke volume (P = 0.024). In addition, it decreased transmitral E-peak velocity (P = 0.012) and increased deceleration time of E-peak (P = 0.021). In conclusion the diving response, already evident during shallow diving (5 m) did not progress during deeper dives (10 m). The rapid improvement in systolic and diastolic function observed after lung volume expansion is congruous with the idea of a constrictive effect on the heart exerted by chest squeeze.
[European Resuscitation Council guidelines for resuscitation 2010].
Hunyadi-Anticević, Silvija; Colak, Zeljko; Funtak, Ines Lojna; Lukić, Anita; Filipović-Grcić, Boris; Tomljanović, Branka; Kniewald, Hrvoje; Protić, Alen; Pandak, Tatjana; Poljaković, Zdravka; Canadija, Marino
2011-01-01
All rescuers trained or not, should provide chest compressions to victims of cardiac arrest. The aim should be to push to a depth of at least 5 cm at a rate of at least 100 compressions per minute, to allow full chest recoil, and to minimise interruptions in chest compressions. Trained rescuers should also provide ventilations with a compression-ventilation ratio of 30:2. ELECTRICAL THERAPIES: Much greater emphasis on minimising the duration of the pre-shock and post-shock pauses; the continuation of compressions during charging of the defibrillator is recommended. Further development of AED programmes is encouraged. ADULT ADVANCED LIFE SUPPORT: Increased emphasis on high-quality chest compressions throughout any ALS intervention paused briefly only to enable specific interventions. Removal of the recommendation for a pre-specified period of cardiopulmonary resuscitation before out-of-hospital defibrillation following cardiac arrest unwitnessed by the EMS. The role of precordial thump is de-emphasized. Delivery of drugs via a tracheal tube is no longer recommended, drugs should be given by the intraosseous (IO) route. Atropine is no longer recommended for routine use in asystole or pulseless electrical activity. Reduced emphasis on early tracheal intubation unless achieved by highly skilled individuals with minimal interruptions in chest compressions. Increased emphasis on the use of capnography. Recognition of potential harm caused by hyperoxaemia. Revision of the recommendation of glucose control. Use of therapeutic hypothermia to include comatose survivors of cardiac arrest associated initially with shockable rhythms, as well as non-shockable rhythms, with a lower level of evidence acknowledged for the latter. INITIAL MANAGEMENT OF ACUTE CORONARY SYNDROMES: The term non-ST-elevation myocardial infarction-acute coronary syndrome (non-STEMI-ACS) has been introduced for both NSTEMI and unstable angina pectoris. Primary PCI (PPCI) is the preferred reperfusion strategy provided it is performed in a timely manner by an experienced team. Non-steroidal anti-inflammatory drugs should be avoided, as well as routine use of intravenous beta-blockers; oxygen is to be given only to those patients with hypoxaemia, breathlessness or pulmonary congestion. PAEDIATRIC LIFE SUPPORT: The decision to begin resuscitation must be taken in less than 10 seconds. Lay rescuers should be taught to use a ratio of 30 compressions to 2 ventilations, rescuers with a duty to respond should learn and use a 15:2 ratio; however, they can use the 30:2 compression-ventilation ratio if they are alone. Ventilation remains a very important component of resuscitation in asphyxial arrest. The emphasis is on achieving quality compressions with the rate of at least 100 but not greater than 120 per minute, with minimal interruptions. AEDs are safe and successful when used in children older than 1 year. A single shock strategy using a non-escalating dose of 4 J/kg is recommended for defibrillation in children. Cuffed tubes can be used safely in infants and young children. Monitoring exhaled carbon dioxide (CO2), ideally by capnography, is recommended during resuscitation. RESUSCITATION OF BABIES AT BIRTH: For uncompromised babies, a delay in cord clamping of at least one minute from the complete delivery is now recommended. For term infants, air should be used fro resuscitation at birth. For preterm babies less than 32 weeks gestation blended oxygen and air should be given judiciously and its use guided by pulse oximetry. Preterm babies of less than 28 weeks gestation should be completely covered in a plastic wrap up to their necks, without drying, immediately after birth. The recommended compression: ventilation ratio remains at 3:1 for newborn resuscitation. Attempts to aspirate meconium from the nose and mouth of the unborn baby, while the head is still on the perineum, are not recommended. If adrenaline is given the n the intravenous route is recommended using a dose of 10-30 microg/kg. Newly born infants born at term or near-term with moderate to severe hypoxic-ischaemic encephalopathy should be treated with therapeutic hypothermia. PRINCIPLES OF EDUCATION IN RESUSCITATION: The aim is to ensure that learners acquire and retain skill and knowledge that will enable them to act correctly in actual cardiac arrest and improve patient outcome. Short video/computer self-instruction courses, with minimal or no instructor coaching, combined with hands-on practice can be considered as an effective alternative to instructor-led basic life support (BLS and AED) courses. Ideally all citizens should be trained in standard CPR that includes compressions and ventilations. Basic and advanced life support knowledge and skills deteriorate in as little as three to six months. CPR prompt or feedback devices improve CPR skill acquisition and retention.
A method of automatic control procedures cardiopulmonary resuscitation
NASA Astrophysics Data System (ADS)
Bureev, A. Sh.; Zhdanov, D. S.; Kiseleva, E. Yu.; Kutsov, M. S.; Trifonov, A. Yu.
2015-11-01
The study is to present the results of works on creation of methods of automatic control procedures of cardiopulmonary resuscitation (CPR). A method of automatic control procedure of CPR by evaluating the acoustic data of the dynamics of blood flow in the bifurcation of carotid arteries and the dynamics of air flow in a trachea according to the current guidelines for CPR is presented. Evaluation of the patient is carried out by analyzing the respiratory noise and blood flow in the interspaces between the chest compressions and artificial pulmonary ventilation. The device operation algorithm of automatic control procedures of CPR and its block diagram has been developed.
Lee, Chang Jae; Chung, Tae Nyoung; Bae, Jinkun; Kim, Eui Chung; Choi, Sung Wook; Kim, Ok Jun
2015-03-01
Current guidelines for cardiopulmonary resuscitation recommend chest compressions (CC) during 50% of the duty cycle (DC) in part because of the ease with which individuals may learn to achieve it with practice. However, no consideration has been given to a possible interaction between DC and depth of CC, which has been the subject of recent study. Our aim was to determine if 50% DC is inappropriate to achieve sufficient chest compression depth for female and light rescuers. Previously collected CC data, performed by senior medical students guided by metronome sounds with various down-stroke patterns and rates, were included in the analysis. Multiple linear regression analysis was performed to determine the association between average compression depth (ACD) with average compression rate (ACR), DC, and physical characteristics of the performers. Expected ACD was calculated for various settings. DC, ACR, body weight, male sex, and self-assessed physical strength were significantly associated with ACD in multivariate analysis. Based on our calculations, with 50% of DC, only men with ACR of 140/min or faster or body weight over 74 kg with ACR of 120/min can achieve sufficient ACD. A shorter DC is independently correlated with deeper CC during simulated cardiopulmonary resuscitation. The optimal DC recommended in current guidelines may be inappropriate for achieving sufficient CD, especially for female or lighter-weight rescuers.
Accuracy of remote chest X-ray interpretation using Google Glass technology.
Spaedy, Emily; Christakopoulos, Georgios E; Tarar, Muhammad Nauman J; Christopoulos, Georgios; Rangan, Bavana V; Roesle, Michele; Ochoa, Cristhiaan D; Yarbrough, William; Banerjee, Subhash; Brilakis, Emmanouil S
2016-09-15
We sought to explore the accuracy of remote chest X-ray reading using hands-free, wearable technology (Google Glass, Google, Mountain View, California). We compared interpretation of twelve chest X-rays with 23 major cardiopulmonary findings by faculty and fellows from cardiology, radiology, and pulmonary-critical care via: (1) viewing the chest X-ray image on the Google Glass screen; (2) viewing a photograph of the chest X-ray taken using Google Glass and interpreted on a mobile device; (3) viewing the original chest X-ray on a desktop computer screen. One point was given for identification of each correct finding and a subjective rating of user experience was recorded. Fifteen physicians (5 faculty and 10 fellows) participated. The average chest X-ray reading score (maximum 23 points) as viewed through the Google Glass, Google Glass photograph on a mobile device, and the original X-ray viewed on a desktop computer was 14.1±2.2, 18.5±1.5 and 21.3±1.7, respectively (p<0.0001 between Google Glass and mobile device, p<0.0001 between Google Glass and desktop computer and p=0.0004 between mobile device and desktop computer). Of 15 physicians, 11 (73.3%) felt confident in detecting findings using the photograph taken by Google Glass as viewed on a mobile device. Remote chest X-ray interpretation using hands-free, wearable technology (Google Glass) is less accurate than interpretation using a desktop computer or a mobile device, suggesting that further technical improvements are needed before widespread application of this novel technology. Published by Elsevier Ireland Ltd.
[Compressive anterior thoracoplasty (modified Abramson's repair) for pectus carinatum repair].
Álvarez Muñoz, V; Prado Valle, M A; López López, A J; Martínez Suárez, M A; Oviedo Gutiérrez, M; Montalvo Ávalos, C; Fernández García, L
2014-04-15
For anterior protruding chest wall deformities treatment, mainly pectus carinatum, pediatric surgeons have been managing either orthotic methods or open surgical repairs. Anterior compressive thoracoplasty (Abramson's technique) has widened the therapeutic options. We describe herein a modification of this technique in the first reported Europen series. From 2010 to 2012, a total of five patients (four male and one female) underwent a modified Abramson's technique to correct pectus carinatum or combined protrusion of the chest at our center. We report the operative technique used for these reconstructions. In all five cases, the operation was completed uneventfully and with excellent results either for the surgical team or the patients. Mean operative time was 190 minutes and hospitalization lasted for three to six days, at the time of analgesic drugs withdrawal. We consider the anterior compresive thorocoplasty (modified Abramson's technique) a safe and feasible method to correct protruding chest deformities, particularly in those patients with stiff chest or lack of compliance, in order to avoid the agressive open procedures.
Cystic Fibrosis Chest X-Ray Findings: A Teaching Analog
2008-07-01
lung volume. There are five specific types of atelectasis: obstructive, compressive, cicatrization , post-operative and adhesive. Obstructive...commonly, a pleural lesion or mass can cause impact on the neighboring lung tissue causing compression of the alveoli in that area. Cicatrization ...Lymphoma Atelectasis Obstructive Compressive Pneumothorax Pleural Effusion Pleural Lesion Cicatrization Radiation Severe Pneumonia Adhesive
Lee, Soo Hoon; Kim, Dong Hoon; Kang, Tae-Sin; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kim, Dong Seob
2015-08-01
This study was conducted to evaluate the appropriateness of the chest compression (CC) depth recommended in the current guidelines and simulated external CCs, and to characterize the optimal CC depth for an adult by body mass index (BMI). Adult patients who underwent chest computed tomography as a screening test for latent pulmonary diseases in the health care center were enrolled in this study. We calculated the internal anteroposterior (AP) diameter (IAPD) and external AP diameter (EAPD) of the chest across BMIs (<18.50, 18.50-24.99, 25.00-29.99, and ≥30.00 kg/m(2)) for simulated CC depth. We also calculated the residual chest depths less than 20 mm for simulated CC depth. There was a statistically significant difference in the chest EAPD and IAPD measured at the lower half of the sternum for each BMI groups (EAPD: R(2) = 0.638, P < .001; IAPD: R(2) = 0.297, P < .001). For one-half external AP CC, 100% of the patients, regardless of BMI, had a calculated residual internal chest depth less than 20 mm. For one-fourth external AP CC, no patients had a calculated residual internal chest depth less than 20 mm. For one-third external AP CC, only 6.48% of the patients had a calculated residual internal chest depth less than 20 mm. It is not appropriate that the current CC depth (≥50 mm), expressed only as absolute measurement without a fraction of the depth of the chest, is applied uniformly in all adults. In addition, in terms of safety and efficacy, simulated CC targeting approximately between one-third and one-fourth EAPD CC depth might be appropriate. Copyright © 2015 Elsevier Inc. All rights reserved.
Kim, Jong Won; Lee, Jeong Hun; Lee, Kyeong Ryong; Hong, Dae Young; Baek, Kwang Je; Park, Sang O
2016-08-01
This study investigated the effect of increasing numbers of training sessions in cardiopulmonary resuscitation (CPR) on trainees' attitude and CPR quality. Cardiopulmonary resuscitation training for hospital employees was held every year from 2006 to 2010. Participants were recruited among the trainees in 2010. The trainees' attitudes toward CPR were surveyed by questionnaire, and the quality of their CPR was measured using 5-cycle 30:2 CPR on a manikin. Participants were categorized according to the number of consecutive CPR training sessions as T1 (only 2010), T2 (2009 and 2010), T3 (from 2008 to 2010) and T4-5 (from 2006 or 2007 to 2010). The trainee attitude and CPR quality were compared among the 4 groups. Of 923 CPR trainees, 267 were enrolled in the study. There was significant increase in willingness to start CPR and confidence in chest compression and mouth-to-mouth ventilation (MTMV) with increasing number of CPR training sessions attended (especially for ≥ 3 sessions). There was a significant increase in mean compression depth and decrease in percentage of chest compressions with depth of less than 38 mm in the T3 and T4-5 compared with the T1 and T2. No-flow time decreased significantly, and the percentage of MTMV with visible chest rise increased, as the number of training sessions increased. Repeated CPR training improved trainees' attitude and CPR quality. Because the number of training sessions increased (≥3), the willingness to start CPR and the confidence in skills increased significantly, and chest compression depth, no-flow time, and MTMV improved.
van Tulder, Raphael; Laggner, Roberta; Kienbacher, Calvin; Schmid, Bernhard; Zajicek, Andreas; Haidvogel, Jochen; Sebald, Dieter; Laggner, Anton N; Herkner, Harald; Sterz, Fritz; Eisenburger, Philip
2015-04-01
In CPR, sufficient compression depth is essential. The American Heart Association ("at least 5cm", AHA-R) and the European Resuscitation Council ("at least 5cm, but not to exceed 6cm", ERC-R) recommendations differ, and both are hardly achieved. This study aims to investigate the effects of differing target depth instructions on compression depth performances of professional and lay-rescuers. 110 professional-rescuers and 110 lay-rescuers were randomized (1:1, 4 groups) to estimate the AHA-R or ERC-R on a paper sheet (given horizontal axis) using a pencil and to perform chest compressions according to AHA-R or ERC-R on a manikin. Distance estimation and compression depth were the outcome variables. Professional-rescuers estimated the distance according to AHA-R in 19/55 (34.5%) and to ERC-R in 20/55 (36.4%) cases (p=0.84). Professional-rescuers achieved correct compression depth according to AHA-R in 39/55 (70.9%) and to ERC-R in 36/55 (65.4%) cases (p=0.97). Lay-rescuers estimated the distance correctly according to AHA-R in 18/55 (32.7%) and to ERC-R in 20/55 (36.4%) cases (p=0.59). Lay-rescuers yielded correct compression depth according to AHA-R in 39/55 (70.9%) and to ERC-R in 26/55 (47.3%) cases (p=0.02). Professional and lay-rescuers have severe difficulties in correctly estimating distance on a sheet of paper. Professional-rescuers are able to yield AHA-R and ERC-R targets likewise. In lay-rescuers AHA-R was associated with significantly higher success rates. The inability to estimate distance could explain the failure to appropriately perform chest compressions. For teaching lay-rescuers, the AHA-R with no upper limit of compression depth might be preferable. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...
42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...
McGrane, J; Carswell, S; Talbot, T
2017-01-01
We report a case of a 66-year-old man with locally advanced and metastatic basal cell carcinoma (BCC) causing spinal cord compression, which was treated with spinal surgery and subsequent vismodegib. The patient presented with a large fungating chest wall lesion and a metastasis in T8 that was causing cord compression. He had neurosurgical decompression of the T8 lesion and fixation of the spine. Punch biopsy from the fungating chest wall lesion showed a BCC with some malignant squamous differentiation (basosquamous). Histopathological examination of the metastatic lesion in T8 at the time of surgical decompression identified features identical to the punch biopsy. The patient was referred to the oncology clinic for adjuvant treatment. In light of his metastatic disease and the large area over his chest wall that could not fully be covered by radiotherapy, he was treated with the novel oral Hedgehog signalling pathway (HHSP) inhibitor vismodegib, which led to marked improvement. © 2016 British Association of Dermatologists.
Brace Compression for Treatment of Pectus Carinatum
Jung, Joonho; Chung, Sang Ho; Cho, Jin Kyoung; Park, Soo-Jin; Choi, Ho
2012-01-01
Background Surgery has been the classical treatment of pectus carinatum (PC), though compressive orthotic braces have shown successful results in recent years. We propose a non-operative approach using a lightweight, patient-controlled dynamic chest-bracing device. Materials and Methods Eighteen patients with PC were treated between July 2008 and June 2009. The treatment involved fitting of the brace, which was worn for at least 20 hours per day for 6 months. Their degree of satisfaction (1, no correction; 4, remarkable correction) was measured at 12 months after the initiation of the treatment. Results Thirteen (72.2%) patients completed the treatment (mean time, 4.9±1.4 months). In patients who completed the treatment, the mean overall satisfaction score was 3.73±0.39. The mean satisfaction score was 4, and there was no recurrence of pectus carinatum in patients who underwent the treatment for at least 6 months. Minimal recurrence of pectus carinatum after removal of the compressive brace occurred in 5 (38.5%) patients who stopped wearing the compressive brace at 4 months. Conclusion Compressive bracing results in a significant improvement in PC appearance in patients with an immature skeleton. However, patient compliance and diligent follow-up appear to be paramount for the success of this method of treatment. We currently offer this approach as a first-line treatment for PC. PMID:23275922
Lee, Chang Jae; Chung, Tae Nyoung; Bae, Jinkun; Kim, Eui Chung; Choi, Sung Wook; Kim, Ok Jun
2015-01-01
Objective Current guidelines for cardiopulmonary resuscitation recommend chest compressions (CC) during 50% of the duty cycle (DC) in part because of the ease with which individuals may learn to achieve it with practice. However, no consideration has been given to a possible interaction between DC and depth of CC, which has been the subject of recent study. Our aim was to determine if 50% DC is inappropriate to achieve sufficient chest compression depth for female and light rescuers. Methods Previously collected CC data, performed by senior medical students guided by metronome sounds with various down-stroke patterns and rates, were included in the analysis. Multiple linear regression analysis was performed to determine the association between average compression depth (ACD) with average compression rate (ACR), DC, and physical characteristics of the performers. Expected ACD was calculated for various settings. Results DC, ACR, body weight, male sex, and self-assessed physical strength were significantly associated with ACD in multivariate analysis. Based on our calculations, with 50% of DC, only men with ACR of 140/min or faster or body weight over 74 kg with ACR of 120/min can achieve sufficient ACD. Conclusion A shorter DC is independently correlated with deeper CC during simulated cardiopulmonary resuscitation. The optimal DC recommended in current guidelines may be inappropriate for achieving sufficient CD, especially for female or lighter-weight rescuers. PMID:27752567
Bobrow, Bentley J; Vadeboncoeur, Tyler F; Stolz, Uwe; Silver, Annemarie E; Tobin, John M; Crawford, Scott A; Mason, Terence K; Schirmer, Jerome; Smith, Gary A; Spaite, Daniel W
2013-07-01
We assess whether an initiative to optimize out-of-hospital provider cardiopulmonary resuscitation (CPR) quality is associated with improved CPR quality and increased survival from out-of-hospital cardiac arrest. This was a before-after study of consecutive adult out-of-hospital cardiac arrest. Data were obtained from out-of-hospital forms and defibrillators. Phase 1 included 18 months with real-time audiovisual feedback disabled (October 2008 to March 2010). Phase 2 included 16 months (May 2010 to September 2011) after scenario-based training of 373 professional rescuers and real-time audiovisual feedback enabled. The effect of interventions on survival to hospital discharge was assessed with multivariable logistic regression. Multiple imputation of missing data was used to analyze the effect of interventions on CPR quality. Analysis included 484 out-of-hospital cardiac arrest patients (phase 1 232; phase 2 252). Median age was 68 years (interquartile range 56-79); 66.5% were men. CPR quality measures improved significantly from phase 1 to phase 2: Mean chest compression rate decreased from 128 to 106 chest compressions per minute (difference -23 chest compressions; 95% confidence interval [CI] -26 to -19 chest compressions); mean chest compression depth increased from 1.78 to 2.15 inches (difference 0.38 inches; 95% CI 0.28 to 0.47 inches); median chest compression fraction increased from 66.2% to 83.7% (difference 17.6%; 95% CI 15.0% to 20.1%); median preshock pause decreased from 26.9 to 15.5 seconds (difference -11.4 seconds; 95% CI -15.7 to -7.2 seconds), and mean ventilation rate decreased from 11.7 to 9.5/minute (difference -2.2/minute; 95% CI -3.9 to -0.5/minute). All-rhythms survival increased from phase 1 to phase 2 (20/231, 8.7% versus 35/252, 13.9%; difference 5.2%; 95% CI -0.4% to 10.8%), with an adjusted odds ratio of 2.72 (95% CI 1.15 to 6.41), controlling for initial rhythm, witnessed arrest, age, minimally interrupted cardiac resuscitation protocol compliance, and provision of therapeutic hypothermia. Witnessed arrests/shockable rhythms survival was 26.3% (15/57) for phase 1 and 55.6% (20/36) for phase 2 (difference 29.2%; 95% CI 9.4% to 49.1%). Implementation of resuscitation training combined with real-time audiovisual feedback was independently associated with improved CPR quality, an increase in survival, and favorable functional outcomes after out-of-hospital cardiac arrest. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.
Adelborg, K; Bjørnshave, K; Mortensen, M B; Espeseth, E; Wolff, A; Løfgren, B
2014-07-01
Thirty surf lifeguards (mean (SD) age: 25.1 (4.8) years; 21 male, 9 female) were randomly assigned to perform 2 × 3 min of cardiopulmonary resuscitation on a manikin using mouth-to-face-shield ventilation (AMBU LifeKey) and mouth-to-pocket-mask ventilation (Laerdal Pocket Mask). Interruptions in chest compressions, effective ventilation (visible chest rise) ratio, tidal volume and inspiratory time were recorded. Interruptions in chest compressions per cycle were increased with mouth-to-face-shield ventilation (mean (SD) 8.6 (1.7) s) compared with mouth-to-pocket-mask ventilation (6.9 (1.2) s, p < 0.0001). The proportion of effective ventilations was less using mouth-to-face-shield ventilation (199/242 (82%)) compared with mouth-to-pocket-mask ventilation (239/240 (100%), p = 0.0002). Tidal volume was lower using mouth-to-face-shield ventilation (mean (SD) 0.36 (0.20) l) compared with mouth-to-pocket-mask ventilation (0.45 (0.20) l, p = 0.006). No differences in inspiratory times were observed between mouth-to-face-shield ventilation and mouth-to-pocket-mask ventilation. In conclusion, mouth-to-face-shield ventilation increases interruptions in chest compressions, reduces the proportion of effective ventilations and decreases delivered tidal volumes compared with mouth-to-pocket-mask ventilation. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Friess, Stuart H; Sutton, Robert M; Bhalala, Utpal; Maltese, Matthew R; Naim, Maryam Y; Bratinov, George; Weiland, Theodore R; Garuccio, Mia; Nadkarni, Vinay M; Becker, Lance B; Berg, Robert A
2013-12-01
During cardiopulmonary resuscitation, adequate coronary perfusion pressure is essential for establishing return of spontaneous circulation. Current American Heart Association guidelines recommend standardized interval administration of epinephrine for patients in cardiac arrest. The objective of this study was to compare short-term survival using a hemodynamic directed resuscitation strategy versus chest compression depth-directed cardiopulmonary resuscitation in a porcine model of cardiac arrest. Randomized interventional study. Preclinical animal laboratory. Twenty-four 3-month-old female swine. After 7 minutes of ventricular fibrillation, pigs were randomized to receive one of three resuscitation strategies: 1) Hemodynamic directed care (coronary perfusion pressure-20): chest compressions with depth titrated to a target systolic blood pressure of 100 mm Hg and titration of vasopressors to maintain coronary perfusion pressure greater than 20 mm Hg; 2) Depth 33 mm: target chest compression depth of 33 mm with standard American Heart Association epinephrine dosing; or 3) Depth 51 mm: target chest compression depth of 51 mm with standard American Heart Association epinephrine dosing. All animals received manual cardiopulmonary resuscitation guided by audiovisual feedback for 10 minutes before first shock. Forty-five-minute survival was higher in the coronary perfusion pressure-20 group (8 of 8) compared to depth 33 mm (1 of 8) or depth 51 mm (3 of 8) groups; p equals to 0.002. Coronary perfusion pressures were higher in the coronary perfusion pressure-20 group compared to depth 33 mm (p = 0.004) and depth 51 mm (p = 0.006) and in survivors compared to nonsurvivors (p < 0.01). Total epinephrine dosing and defibrillation attempts were not different. Hemodynamic directed resuscitation targeting coronary perfusion pressures greater than 20 mm Hg during 10 minutes of cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest improves short-term survival, when compared to resuscitation with depth of compressions guided to 33 mm or 51 mm and standard American Heart Association vasopressor dosing.
Lin, Yu-You; Chiang, Wen-Chu; Hsieh, Ming-Ju; Sun, Jen-Tang; Chang, Yi-Chung; Ma, Matthew Huei-Ming
2018-02-01
This study aimed to conduct a systematic review and meta-analysis comparing the effect of video-assistance and audio-assistance on quality of dispatcher-instructed cardiopulmonary resuscitation (DI-CPR) for bystanders. Five databases were searched, including PubMed, Cochrane library, Embase, Scopus and NIH clinical trial, to find randomized control trials published before June 2017. Qualitative analysis and meta-analysis were undertaken to examine the difference between the quality of video-instructed and audio-instructed dispatcher-instructed bystander CPR. The database search yielded 929 records, resulting in the inclusion of 9 relevant articles in this study. Of these, 6 were included in the meta-analysis. Initiation of chest compressions was slower in the video-instructed group than in the audio-instructed group (median delay 31.5 s; 95% CI: 10.94-52.09). The difference in the number of chest compressions per minute between the groups was 19.9 (95% CI: 10.50-29.38) with significantly faster compressions in the video-instructed group than in the audio-instructed group (104.8 vs. 80.6). The odds ratio (OR) for correct hand positioning was 0.8 (95% CI: 0.53-1.30) when comparing the audio-instructed and video-instructed groups. The differences in chest compression depth (mm) and time to first ventilation (seconds) between the video-instructed group and audio-instructed group were 1.6 mm (95% CI: -8.75, 5.55) and 7.5 s (95% CI: -56.84, 71.80), respectively. Video-instructed DI-CPR significantly improved the chest compression rate compared to the audio-instructed method, and a trend for correctness of hand position was also observed. However, this method caused a delay in the commencement of bystander-initiated CPR in the simulation setting. Copyright © 2017 Elsevier B.V. All rights reserved.
You, Je Sung; Kim, Hoon; Park, Jung Soo; Baek, Kyung Min; Jang, Mun Sun; Lee, Hye Sun; Chung, Sung Phil; Kim, SeungWhan
2015-03-01
The major components affecting high quality cardiopulmonary resuscitation (CPR) have been defined as the ability of the rescuer, hand position, position of the rescuer and victim, depth and rate of chest compressions, and fatigue. Until now, there have been no studies on dominant versus non-dominant hand position and the rescuer's side of approach. This study was designed to evaluate the effectiveness of hand position and approach side on the quality of CPR between right-handed (RH) and left-handed (LH) novice rescuers. 44 health science university students with no previous experience of basic life support (BLS) volunteered for the study. We divided volunteers into two groups by handedness. Adult BLS was performed on a manikin for 2 min in each session. The sequences were randomly performed on the manikin's left side of approach (Lap) with the rescuer's left hand in contact with the sternum (Lst), Lap/Rst, Rap/Lst and Rap/Rst. We compared the quality of chest compressions between the RH and LH groups according to predetermined positions. A significant decrease in mean compression depth between the two groups was only observed when rescuers performed in the Rap/Lst scenario, regardless of hand dominance. The frequency of correct hand placement also significantly decreased in the Lap/Rst position for the LH group. The performance of novice rescuers during chest compressions is influenced by the position of the dominant hand and the rescuer's side of approach. In CPR training and real world situations, a novice rescuer, regardless of handedness, should consider hand positions for contacting the sternum identical to the side of approach after approaching from the nearest and most accessible side, for optimal CPR performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Bjørshol, Conrad Arnfinn; Myklebust, Helge; Nilsen, Kjetil Lønne; Hoff, Thomas; Bjørkli, Cato; Illguth, Eirik; Søreide, Eldar; Sunde, Kjetil
2011-02-01
The aim of this study was to evaluate whether socioemotional stress affects the quality of cardiopulmonary resuscitation during advanced life support in a simulated manikin model. A randomized crossover trial with advanced life support performed in two different conditions, with and without exposure to socioemotional stress. The study was conducted at the Stavanger Acute Medicine Foundation for Education and Research simulation center, Stavanger, Norway. Paramedic teams, each consisting of two paramedics and one assistant, employed at Stavanger University Hospital, Stavanger, Norway. A total of 19 paramedic teams performed advanced life support twice in a randomized fashion, one control condition without socioemotional stress and one experimental condition with exposure to socioemotional stress. The socioemotional stress consisted of an upset friend of the simulated patient who was a physician, spoke a foreign language, was unfamiliar with current Norwegian resuscitation guidelines, supplied irrelevant clinical information, and repeatedly made doubts about the paramedics' resuscitation efforts. Aural distractions were supplied by television and cell telephone. The primary outcome was the quality of cardiopulmonary resuscitation: chest compression depth, chest compression rate, time without chest compressions (no-flow ratio), and ventilation rate after endotracheal intubation. As a secondary outcome, the socioemotional stress impact was evaluated through the paramedics' subjective workload, frustration, and feeling of realism. There were no significant differences in chest compression depth (39 vs. 38 mm, p = .214), compression rate (113 vs. 116 min⁻¹, p = .065), no-flow ratio (0.15 vs. 0.15, p = .618), or ventilation rate (8.2 vs. 7.7 min⁻¹, p = .120) between the two conditions. There was a significant increase in the subjective workload, frustration, and feeling of realism when the paramedics were exposed to socioemotional stress. In this advanced life support manikin study, the presence of socioemotional stress increased the subjective workload, frustration, and feeling of realism, without affecting the quality of cardiopulmonary resuscitation.
Mobile phone-assisted basic life support augmented with a metronome.
Paal, Peter; Pircher, Iris; Baur, Thomas; Gruber, Elisabeth; Strasak, Alexander M; Herff, Holger; Brugger, Hermann; Wenzel, Volker; Mitterlechner, Thomas
2012-09-01
Basic life support (BLS) performed by lay rescuers is poor. We developed software for mobile phones augmented with a metronome to improve BLS. To assess BLS in lay rescuers with or without software assistance. Medically untrained volunteers were randomized to run through a cardiac arrest scenario with ("assisted BLS") or without ("non-assisted BLS") the aid of a BLS software program installed on a mobile phone. Sixty-four lay rescuers were enrolled in the "assisted BLS" and 77 in the "non-assisted BLS" group. The "assisted BLS" when compared to the "non-assisted BLS" group, achieved a higher overall score (19.2 ± 7.5 vs. 12.9 ± 5.7 credits; p < 0.001). Moreover, the "assisted BLS" when compared to the "non-assisted" group checked (64% vs. 27%) and protected themselves more often from environmental risks (70% vs. 39%); this group also called more often for help (56% vs. 27%), opened the upper airway (78% vs. 16%), and had more correct chest compressions rates (44% ± 38% vs. 14% ± 28%; all p < 0.001). However, the "assisted BLS" when compared to the "non-assisted BLS" group, was slower in calling the dispatch center (113.6 ± 86.4 vs. 54.1 ± 45.1 s; p < 0.001) and starting chest compressions (165.3 ± 93.3 vs. 87.1 ± 53.2 s; p < 0.001). "Assisted BLS" augmented by a metronome resulted in a higher overall score and a better chest compression rate when compared to "non-assisted BLS." However, in the "assisted BLS" group, time to call the dispatch center and to start chest compressions was longer. In both groups, lay persons did not ventilate satisfactorily during this cardiac arrest scenario. Copyright © 2012 Elsevier Inc. All rights reserved.
Perception of CPR quality: Influence of CPR feedback, Just-in-Time CPR training and provider role.
Cheng, Adam; Overly, Frank; Kessler, David; Nadkarni, Vinay M; Lin, Yiqun; Doan, Quynh; Duff, Jonathan P; Tofil, Nancy M; Bhanji, Farhan; Adler, Mark; Charnovich, Alex; Hunt, Elizabeth A; Brown, Linda L
2015-02-01
Many healthcare providers rely on visual perception to guide cardiopulmonary resuscitation (CPR), but little is known about the accuracy of provider perceptions of CPR quality. We aimed to describe the difference between perceived versus measured CPR quality, and to determine the impact of provider role, real-time visual CPR feedback and Just-in-Time (JIT) CPR training on provider perceptions. We conducted secondary analyses of data collected from a prospective, multicenter, randomized trial of 324 healthcare providers who participated in a simulated cardiac arrest scenario between July 2012 and April 2014. Participants were randomized to one of four permutations of: JIT CPR training and real-time visual CPR feedback. We calculated the difference between perceived and measured quality of CPR and reported the proportion of subjects accurately estimating the quality of CPR within each study arm. Participants overestimated achieving adequate chest compression depth (mean difference range: 16.1-60.6%) and rate (range: 0.2-51%), and underestimated chest compression fraction (0.2-2.9%) across all arms. Compared to no intervention, the use of real-time feedback and JIT CPR training (alone or in combination) improved perception of depth (p<0.001). Accurate estimation of CPR quality was poor for chest compression depth (0-13%), rate (5-46%) and chest compression fraction (60-63%). Perception of depth is more accurate in CPR providers versus team leaders (27.8% vs. 7.4%; p=0.043) when using real-time feedback. Healthcare providers' visual perception of CPR quality is poor. Perceptions of CPR depth are improved by using real-time visual feedback and with prior JIT CPR training. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Pytte, Morten; Kramer-Johansen, Jo; Eilevstjønn, Joar; Eriksen, Morten; Strømme, Taevje A; Godang, Kristin; Wik, Lars; Steen, Petter Andreas; Sunde, Kjetil
2006-12-01
Adrenaline (epinephrine) is used during cardiopulmonary resuscitation (CPR) based on animal experiments without supportive clinical data. Clinically CPR was reported recently to have much poorer quality than expected from international guidelines and what is generally done in laboratory experiments. We have studied the haemodynamic effects of adrenaline during CPR with good laboratory quality and with quality simulating clinical findings and the feasibility of monitoring these effects through VF waveform analysis. After 4 min of cardiac arrest, followed by 4 min of basic life support, 14 pigs were randomised to ClinicalCPR (intermittent manual chest compressions, compression-to-ventilation ratio 15:2, compression depth 30-38 mm) or LabCPR (continuous mechanical chest compressions, 12 ventilations/min, compression depth 45 mm). Adrenaline 0.02 mg/kg was administered 30 s thereafter. Plasma adrenaline concentration peaked earlier with LabCPR than with ClinicalCPR, median (range), 90 (30, 150) versus 150 (90, 270) s (p = 0.007), respectively. Coronary perfusion pressure (CPP) and cortical cerebral blood flow (CCBF) increased and femoral blood flow (FBF) decreased after adrenaline during LabCPR (mean differences (95% CI) CPP 17 (6, 29) mmHg (p = 0.01), FBF -5.0 (-8.8, -1.2) ml min(-1) (p = 0.02) and median difference CCBF 12% of baseline (p = 0.04)). There were no significant effects during ClinicalCPR (mean differences (95% CI) CPP 4.7 (-3.2, 13) mmHg (p = 0.2), FBF -0.2 (-4.6, 4.2) ml min(-1)(p = 0.9) and CCBF 3.6 (-1.8, 9.0)% of baseline (p = 0.15)). Slope VF waveform analysis reflected changes in CPP. Adrenaline improved haemodynamics during laboratory quality CPR in pigs, but not with quality simulating clinically reported CPR performance.
Lee, Juncheol; Song, Yeongtak; Oh, Jaehoon; Chee, Youngjoon; Ahn, Chiwon; Shin, Hyungoo; Kang, Hyunggoo; Lim, Tae Ho
2018-02-12
According to the guidelines, rescuers should provide chest compressions (CC) ∼1.5 inches (40 mm) for infants. Feedback devices could help rescuers perform CC with adequate rates (CCR) and depths (CCD). However, there is no CC feedback device for infant cardiopulmonary resuscitation (CPR). We suggest a smartwatch-based CC feedback application for infant CPR. We created a smartwatch-based CC feedback application. This application provides feedback on CCD and CCR by colour and text for infant CPR. To evaluate the application, 30 participants were divided randomly into two groups on the basis of whether CC was performed with or without the assistance of the smartwatch application. Both groups performed continuous CC-only CPR for 2 min on an infant mannequin placed on a firm table. We collected CC parameters from the mannequin, including the proportion of correct depth, CCR, CCD and the proportion of correct decompression depth. Demographics between the two groups were not significantly different. The median (interquartile range) proportion of correct depth was 99 (97-100) with feedback compared with 83 (58-97) without feedback (P=0.002). The CCR and proportion of correct decompression depth were not significantly different between the two groups (P=0.482 and 0.089). The CCD of the feedback group was significantly deeper than that of the control group [feedback vs. 41.2 (39.8-41.7) mm vs. 38.6 (36.1-39.6) mm; P=0.004]. Rescuers who receive feedback of CC parameters from a smartwatch could perform adequate CC during infant CPR.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.
O'Clock, George D; Lee, Yong Wan; Lee, Jongwon; Warwick, Warren J
2010-07-01
High-frequency chest compression (HFCC) can be used as a therapeutic intervention to assist in the transport and clearance of mucus and enhance water secretion for cystic fibrosis patients. An HFCC pump-vest and half chest-lung simulation, with 23 lung generations, has been developed using inertance, compliance, viscous friction relationships, and Newton's second law. The simulation has proven to be useful in studying the effects of parameter variations and nonlinear effects on HFCC system performance and pulmonary system response. The simulation also reveals HFCC waveform structure and intensity changes in various segments of the pulmonary system. The HFCC system simulation results agree with measurements, indicating that the HFCC energy transport mechanism involves a mechanically induced pulsation or vibration waveform with average velocities in the lung that are dependent upon small air displacements over large areas associated with the vest-chest interface. In combination with information from lung physiology, autopsies and a variety of other lung modeling efforts, the results of the simulation can reveal a number of therapeutic implications.
Sesia, Sergio B; Holland-Cunz, Stefan; Häcker, Frank-Martin
2016-12-01
Background Several nonoperative treatments are currently available for the correction of pectus carinatum (PC). Objective The objective of this study is to report our single center experience with the dynamic compression system (DCS). Materials and Methods The DCS is a rigid aluminum brace. PC is reshaped into a normal appearance through anterior-posterior pressure and lateral expansion of the chest. Patients with chondrogladiolar PC were considered suitable for the nonoperative treatment with DCS. Results In this study, 53 of 68 children (78%) with chondrogladiolar PC were assessed retrospectively: 2 children were corrected by surgery, 12/53 (23%) treated by a conventional orthesis, 11/53 (21%) remained without therapy because of minor PC, and 36/53 (68%) were treated using the DCS. Of these 36 patients, 17 (47%) are already cured with a good (7/17) to excellent (10/17) cosmetic result after a median treatment period of 9 months (range, 2.5-16 months). The mean daily time of wearing of the device for those 17 patients was 9 hours (range, 5-18). None abandoned the treatment and there were almost no complications. Conclusions Lateral expansion of the chest and the possibility to measure the applied pressure seemed to be the key to DCSs success. We propose the DCS as first choice in the treatment of chondrogladiolar PC in children. Georg Thieme Verlag KG Stuttgart · New York.
Coronary blood flow during cardiopulmonary resuscitation in swine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bellamy, R.F.; DeGuzman, L.R.; Pedersen, D.C.
1984-01-01
Recent papers have raised doubt as to the magnitude of coronary blood flow during closed-chest cardiopulmonary resuscitation. We will describe experiments that concern the methods of coronary flow measurement during cardiopulmonary resuscitation. Nine anesthetized swine were instrumented to allow simultaneous measurements of coronary blood flow by both electromagnetic cuff flow probes and by the radiomicrosphere technique. Cardiac arrest was caused by electrical fibrillation and closed-chest massage was performed by a Thumper (Dixie Medical Inc., Houston). The chest was compressed transversely at a rate of 66 strokes/min. Compression occupied one-half of the massage cycle. Three different Thumper piston strokes were studied:more » 1.5, 2, and 2.5 inches. Mean aortic pressure and total systemic blood flow measured by the radiomicrosphere technique increased as Thumper piston stroke was lengthened (mean +/- SD): 1.5 inch stroke, 23 +/- 4 mm Hg, 525 +/- 195 ml/min; 2 inch stroke, 33 +/- 5 mm Hg, 692 +/- 202 ml/min; 2.5 inch stroke, 40 +/- 6 mm Hg, 817 +/- 321 ml/min. Both methods of coronary flow measurement (electromagnetic (EMF) and radiomicrosphere (RMS)) gave similar results in technically successful preparations (data expressed as percent prearrest flow mean +/- 1 SD): 1.5 inch stroke, EMF 12 +/- 5%, RMS 16 +/- 5%; 2 inch stroke, EMF 30 +/- 6%, RMS 26 +/- 11%; 2.5 inch stroke, EMF 50 +/- 12%, RMS 40 +/- 20%. The phasic coronary flow signal during closed-chest compression indicated that all perfusion occurred during the relaxation phase of the massage cycle. We concluded that coronary blood flow is demonstrable during closed-chest massage, but that the magnitude is unlikely to be more than a fraction of normal.« less
Montes-Tapia, Fernando; Barreto-Arroyo, Itzel; Cura-Esquivel, Idalia; Rodríguez-Taméz, Antonio; de la O-Cavazos, Manuel
2014-02-01
Traumatic asphyxia is a rare condition in children that usually occurs after severe compression to the chest or abdomen. We report 3 cases in patients 18, 20, and 36 months of age who presented signs and symptoms of traumatic asphyxia after car accidents. Two clinical features were consistent in all 3 patients: multiple petechiae on the face and bulbar conjunctival hemorrhage; 2 patients had facial cyanosis, and 1 had facial edema.In children, the number of clinical manifestations that should be evident to diagnose traumatic asphyxia has not been ascertained. However, in any history of trauma with compression of the chest or abdomen and signs of increased intravenous craniocervical pressure, traumatic asphyxia should be suspected.
Observer performance assessment of JPEG-compressed high-resolution chest images
NASA Astrophysics Data System (ADS)
Good, Walter F.; Maitz, Glenn S.; King, Jill L.; Gennari, Rose C.; Gur, David
1999-05-01
The JPEG compression algorithm was tested on a set of 529 chest radiographs that had been digitized at a spatial resolution of 100 micrometer and contrast sensitivity of 12 bits. Images were compressed using five fixed 'psychovisual' quantization tables which produced average compression ratios in the range 15:1 to 61:1, and were then printed onto film. Six experienced radiologists read all cases from the laser printed film, in each of the five compressed modes as well as in the non-compressed mode. For comparison purposes, observers also read the same cases with reduced pixel resolutions of 200 micrometer and 400 micrometer. The specific task involved detecting masses, pneumothoraces, interstitial disease, alveolar infiltrates and rib fractures. Over the range of compression ratios tested, for images digitized at 100 micrometer, we were unable to demonstrate any statistically significant decrease (p greater than 0.05) in observer performance as measured by ROC techniques. However, the observers' subjective assessments of image quality did decrease significantly as image resolution was reduced and suggested a decreasing, but nonsignificant, trend as the compression ratio was increased. The seeming discrepancy between our failure to detect a reduction in observer performance, and other published studies, is likely due to: (1) the higher resolution at which we digitized our images; (2) the higher signal-to-noise ratio of our digitized films versus typical CR images; and (3) our particular choice of an optimized quantization scheme.
Chest Seal Placement for Penetrating Chest Wounds by Prehospital Ground Forces in Afghanistan.
Schauer, Steven G; April, Michael D; Naylor, Jason F; Simon, Erica M; Fisher, Andrew D; Cunningham, Cord W; Morissette, Daniel M; Fernandez, Jessie Renee D; Ryan, Kathy L
Thoracic trauma represents 5% of all battlefield injuries. Communicating pneumothoraces resulting in tension physiology remain an important etiology of prehospital mortality. In addressing penetrating chest trauma, current Tactical Combat Casualty Care (TCCC) guidelines advocate the immediate placement of a vented chest seal device. Although the Committee on TCCC (CoTCCC) has approved numerous chest seal devices for battlefield use, few data exist regarding their use in a combat zone setting. To evaluate adherence to TCCC guidelines for chest seal placement among personnel deployed to Afghanistan. We obtained data from the Prehospital Trauma Registry (PHTR). Joint Trauma System personnel linked patients to the Department of Defense Trauma Registry, when available, for outcome data upon reaching a fixed facility. In the PHTR, we identified 62 patients with documented gunshot wound (GSW) or puncture wound trauma to the chest. The majority (74.2%; n = 46) of these were due to GSW, with the remainder either explosive-based puncture wounds (22.6%; n = 14) or a combination of GSW and explosive (3.2%; n = 2). Of the 62 casualties with documented GSW or puncture wounds, 46 (74.2%) underwent chest seal placement. Higher proportions of patients with medical officers in their chain of care underwent chest seal placement than those that did not (63.0% versus 37.0%). The majority of chest seals placed were not vented. Of patients with a GSW or puncture wound to the chest, 74.2% underwent chest seal placement. Most of the chest seals placed were not vented in accordance with guidelines, despite the guideline update midway through the study period. These data suggest the need to improve predeployment training on TCCC guidelines and matching of the Army logistical supply chain to the devices recommended by the CoTCCC. 2017.
A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique
Lamoureux, Lorissa; Radhakrishnan, Jeejabai; Gazmuri, Raúl J.
2015-01-01
A rat model of electrically-induced ventricular fibrillation followed by cardiac resuscitation using a closed chest technique that incorporates the basic components of cardiopulmonary resuscitation in humans is herein described. The model was developed in 1988 and has been used in approximately 70 peer-reviewed publications examining a myriad of resuscitation aspects including its physiology and pathophysiology, determinants of resuscitability, pharmacologic interventions, and even the effects of cell therapies. The model featured in this presentation includes: (1) vascular catheterization to measure aortic and right atrial pressures, to measure cardiac output by thermodilution, and to electrically induce ventricular fibrillation; and (2) tracheal intubation for positive pressure ventilation with oxygen enriched gas and assessment of the end-tidal CO2. A typical sequence of intervention entails: (1) electrical induction of ventricular fibrillation, (2) chest compression using a mechanical piston device concomitantly with positive pressure ventilation delivering oxygen-enriched gas, (3) electrical shocks to terminate ventricular fibrillation and reestablish cardiac activity, (4) assessment of post-resuscitation hemodynamic and metabolic function, and (5) assessment of survival and recovery of organ function. A robust inventory of measurements is available that includes – but is not limited to – hemodynamic, metabolic, and tissue measurements. The model has been highly effective in developing new resuscitation concepts and examining novel therapeutic interventions before their testing in larger and translationally more relevant animal models of cardiac arrest and resuscitation. PMID:25938619
Busch, Christian Werner; Qalanawi, Mohammed; Kersten, Jan Felix; Kalwa, Tobias Johannes; Scotti, Norman Alexander; Reip, Wikhart; Doehn, Christoph; Maisch, Stefan; Nitzschke, Rainer
2015-10-01
Medical teams with limited experience in performing advanced life support (ALS) or with a low frequency of cardiopulmonary resuscitation (CPR) while on duty, often have difficulty complying with CPR guidelines. This study evaluated whether the quality of CPR of trained medical students, who served as an example of teams with limited experience in ALS, could be improved with device assistance. The primary outcome was the hands-off time (i.e., the percentage of the entire CPR time without chest compressions). The secondary outcome was seven time intervals, which should be as short as possible, and the quality of ventilations and chest compressions on the mannequin. We compared standard CPR equipment to an interactive device with visual and acoustic instructions for ALS workflow measures to guide briefly trained medical students through the ALS algorithm in a full-scale mannequin simulation study with a randomized crossover study design. The study equipment consisted of an automatic external defibrillator and ventilator that were electronically linked and communicating as a single system. Included were regular medical students in the third to sixth years of medical school of one class who provided written informed consent for voluntary participation and for the analysis of their CPR performance data. No exclusion criteria were applied. For statistical measures of evaluation we used an analysis of variance for crossover trials accounting for treatment effect, sequence effect, and carry-over effect, with adjustment for prior practical experience of the participants. Forty-two medical students participated in 21 CPR sessions, each using the standard and study equipment. Regarding the primary end point, the study equipment reduced the hands-off time from 40.1% (95% confidence interval [CI] 36.9-43.4%) to 35.6% (95% CI 32.4-38.9%, p = 0.031) compared with the standard equipment. Within the prespecified secondary end points, study equipment reduced the time interval until the first rescuer changeover from 273 s (95% CI 244-302 s) to 223 s (95% CI 194-253 s, p = 0.001) and increased the percentage of ventilations with a correct tidal volume of 400-600 mL from 34.3% (95% CI 19.0-49.6%) to 60.9% (95% CI 45.6-76.2%, p = 0.018). The assist device increased the rescuers' CPR quality. CPR providers with limited experience or a limited frequency of CPR performance (i.e., rural Emergency Medical Services crew) may potentially benefit from this assist device. Copyright © 2015 Elsevier Inc. All rights reserved.
Yang, Zhengfei; Tang, David; Wu, Xiaobo; Hu, Xianwen; Xu, Jiefeng; Qian, Jie; Yang, Min; Tang, Wanchun
2015-01-01
During cardiopulmonary resuscitation (CPR), myocardial blood flow generated by chest compression rarely exceeds 35% of its normal level. Cardiac output generated by chest compression decreases gradually with the prolongation of cardiac arrest and resuscitation. Early studies have demonstrated that myocardial blood flow during CPR is largely dependent on peripheral vascular resistance. In this study, we investigated the effects of chest compression in combination with physical control of peripheral vascular resistance assisted by tourniquets on myocardial blood flow during CPR. Ventricular fibrillation was induced and untreated for 7 min in ten male domestic pigs weighing between 33 and 37 kg. The animals were then randomized to receive CPR alone or a tourniquet assisted CPR (T-CPR). In the CPR alone group, chest compression was performed by a miniaturized mechanical chest compressor. In the T-CPR group, coincident with the start of resuscitation, the thin elastic tourniquets were wrapped around the four limbs from the distal end to the proximal part. After 2 min of CPR, epinephrine (20 μg/kg) was administered via the femoral vein. After 5 min of CPR, defibrillation was attempted by a single 150 J shock. If resuscitation was not successful, CPR was resumed for 2 min before the next defibrillation. The protocol was continued until successful resuscitation or for a total of 15 min. Five minutes after resuscitation, the elastic tourniquets were removed. The resuscitated animals were observed for 2h. T-CPR generated significantly greater coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow. There was no difference in both intrathoracic positive and negative pressures between the two groups. All animals were successfully resuscitated with a single shock in both groups. There were no significant changes in hemodynamics observed in the animals treated in the T-CPR group before-and-after the release of tourniquets at post-resuscitation 5 min. T-CPR improves myocardial and cerebral perfusion during CPR. It may provide a new and convenient method for augmenting myocardial and cerebral blood flow during CPR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Chung, Sung Phil; Sakamoto, Tetsuya; Lim, Swee Han; Ma, Mathew Huei-Ming; Wang, Tzong-Luen; Lavapie, Francis; Krisanarungson, Sopon; Nonogi, Hiroshi; Hwang, Sung Oh
2016-08-01
This paper introduces adult basic life support (BLS) guidelines for lay rescuers of the resuscitation council of Asia (RCA) developed for the first time. The RCA BLS guidelines for lay rescuers have been established by expert consensus among BLS Guidelines Taskforce of the RCA on the basis of the 2015 International Consensus on Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care Science with Treatment Recommendations. The RCA recommends compression-only CPR for lay rescuers and emphasizes high-quality CPR with chest compression depth of approximately 5cm and chest compression rate of 100-120min(-1). Role of emergency medical dispatchers in helping lay rescuers recognize cardiac arrest and perform CPR is also emphasized. The RCA guidelines will contribute to help Asian countries establish and implement their own CPR guidelines in the context of their domestic circumstances. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Díez, Nieves; Rodríguez-Díez, María-Cristina; Nagore, David; Fernández, Secundino; Ferrer, Marta; Beunza, Juan-Jose
2013-08-01
Current European Resuscitation Guidelines 2010 recommend the use of prompt/feedback devices when training for cardiopulmonary resuscitation (CPR). We aimed to assess the quality of CPR training among second-year medical students with a voice advisory mannequin (VAM) compared to guidance provided by an instructor. Forty-three students received a theoretical reminder about CPR followed by a 2-minute pretest on CPR (compressions/ventilations cycle) with Resusci Anne SkillReporter (Laerdal Medical). They were then randomized into a control group (n = 22), trained by an instructor for 4 minutes per student, and an intervention group (n = 21) trained individually with VAM CPR mannequin for 4 minutes. After training, the students performed a 2-minute posttest, with the same method as the pretest. Participants in the intervention group (VAM) performed more correct hand position (73% vs. 37%; P = 0.014) and tended to display better compression rate (124 min vs. 135 min; P = 0.089). In a stratified analyses by sex we found that only among women trained with VAM was there a significant improvement in compression depth before and after training (36 mm vs. 46 mm, P = 0.018) and in the percentage of insufficient compressions before and after training (56% vs. 15%; P = 0.021). In comparison to the traditional training method involving an instructor, training medical students in CPR with VAM improves the quality of chest compressions in hand position and in compression rate applied to mannequins. Only among women was VAM shown to be superior in compression depth training. This technology reduces costs in 14% in our setup and might potentially release instructors' time for other activities.
Kemper, Andrew R; Beeman, Stephanie M; Madigan, Michael L; Duma, Stefan M
2014-01-01
The purpose of this study was to investigate the effects of pre-impact bracing on the chest compression, reaction forces, and accelerations experienced by human occupants during low-speed frontal sled tests. A total of twenty low-speed frontal sled tests, ten low severity (∼2.5g, Δv=5 kph) and ten medium severity (∼5g, Δv=10 kph), were performed on five 50th-percentile male human volunteers. Each volunteer was exposed to two impulses at each severity, one relaxed and the other braced prior to the impulse. A 59-channel chestband, aligned at the nipple line, was used to quantify the chest contour and anterior-posterior sternum deflection. Three-axis accelerometer cubes were attached to the sternum, 7th cervical vertebra, and sacrum of each subject. In addition, three linear accelerometers and a three-axis angular rate sensor were mounted to a metal mouthpiece worn by each subject. Seatbelt tension load cells were attached to the retractor, shoulder, and lap portions of the standard three-point driver-side seatbelt. In addition, multi-axis load cells were mounted to each interface between the subject and the test buck to quantify reaction forces. For relaxed tests, the higher test severity resulted in significantly larger peak values for all resultant accelerations, all belt forces, and three resultant reaction forces (right foot, seatpan, and seatback). For braced tests, the higher test severity resulted in significantly larger peak values for all resultant accelerations, and two resultant reaction forces (right foot and seatpan). Bracing did not have a significant effect on the occupant accelerations during the low severity tests, but did result in a significant decrease in peak resultant sacrum linear acceleration during the medium severity tests. Bracing was also found to significantly reduce peak shoulder and retractor belt forces for both test severities, and peak lap belt force for the medium test severity. In contrast, bracing resulted in a significant increase in the peak resultant reaction force for the right foot and steering column at both test severities. Chest compression due to belt loading was observed for all relaxed subjects at both test severities, and was found to increase significantly with increasing severity. Conversely, chest compression due to belt loading was essentially eliminated during the braced tests for all but one subject, who sustained minor chest compression due to belt loading during the medium severity braced test. Overall, the data from this study illustrate that muscle activation has a significant effect on the biomechanical response of human occupants in low-speed frontal impacts.
Szarpak, Łukasz; Czyżewski, Łukasz; Kurowski, Andrzej
2015-03-01
The study was designed to compare the effectiveness of 3 video laryngoscopes with the Miller laryngoscope during pediatric resuscitation. This was a randomized crossover study involving 87 paramedics and 54 nurses. The primary end point of the study was the success rate of blind tracheal intubation, whereas the secondary end point was defined as the time from insertion of a device to the first manual ventilation of the manikin's lungs. The median time to intubation using the Pentax, Truview, GlideScope, and Miller varied with the times being 20.6 (interquartile range [IQR], 18-27) vs 20.1 (IQR, 18-23.3) vs 30.2 (IQR, 29.6-35) vs 41.3 (IQR, 33-45.2) seconds, respectively. The overall success ratios of intubation for the devices were 100% vs 100% vs 100% vs 79.4%. We concluded that, in a pediatric manikin scenario, the video laryngoscopes are safe devices and can be used for pediatric intubation during uninterrupted chest compressions. Further clinical studies are necessary to confirm these initial positive findings. Copyright © 2015 Elsevier Inc. All rights reserved.
Retention of Cardiopulmonary Resuscitation Skills by Medical Students.
ERIC Educational Resources Information Center
Fossel, Michael; And Others
1983-01-01
A study of preclinical medical students' cardiopulmonary resuscitation (CPR) skills showed students had a very recent CPR course had a significantly lower failure rate than those with courses one or two years previously. The most frequent errors were in chest compression rate and inability to adhere to the single-rescuer compression-to-ventilation…
Ouweneel, Dagmar M; Sjauw, Krischan D; Wiegerinck, Esther M A; Hirsch, Alexander; Baan, Jan; de Mol, Bas A J M; Lagrand, Wim K; Planken, R Nils; Henriques, José P S
2016-10-01
The use of intracardiac assist devices is expanding, and correct position of these devices is required for optimal functioning. The aortic valve is an important landmark for positioning of those devices. It would be of great value if the device position could be easily monitored on plain supine chest radiograph in the ICU. We introduce a ratio-based tool for determination of the aortic valve location on plain supine chest radiograph images, which can be used to evaluate intracardiac device position. Retrospective observational study. Large academic medical center. Patients admitted to the ICU and supported by an intracardiac assist device. We developed a ratio to determine the aortic valve location on supine chest radiograph images. This ratio is used to assess the position of a cardiac assist device and is compared with echocardiographic findings. Supine anterior-posterior chest radiographs of patients with an aortic valve prosthesis (n = 473) were analyzed to determine the location of the aortic valve. We calculated several ratios with the potential to determine the position of the aortic valve. The aortic valve location ratio, defined as the distance between the carina and the aortic valve, divided by the thoracic width, was found to be the best performing ratio. The aortic valve location ratio determines the location of the aortic valve caudal to the carina, at a distance of 0.25 ± 0.05 times the thoracic width for male patients and 0.28 ± 0.05 times the thoracic width for female patients. The aortic valve location ratio was validated using CT images of patients with angina pectoris without known valvular disease (n = 95). There was a good correlation between cardiac device position (Impella) assessed with the aortic valve location ratio and with echocardiography (n = 53). The aortic valve location ratio enables accurate and reproducible localization of the aortic valve on supine chest radiograph. This tool is easily applicable and can be used for assessment of cardiac device position in patients on the ICU.
A multicenter observer performance study of 3D JPEG2000 compression of thin-slice CT.
Erickson, Bradley J; Krupinski, Elizabeth; Andriole, Katherine P
2010-10-01
The goal of this study was to determine the compression level at which 3D JPEG2000 compression of thin-slice CTs of the chest and abdomen-pelvis becomes visually perceptible. A secondary goal was to determine if residents in training and non-physicians are substantially different from experienced radiologists in their perception of compression-related changes. This study used multidetector computed tomography 3D datasets with 0.625-1-mm thickness slices of standard chest, abdomen, or pelvis, clipped to 12 bits. The Kakadu v5.2 JPEG2000 compression algorithm was used to compress and decompress the 80 examinations creating four sets of images: lossless, 1.5 bpp (8:1), 1 bpp (12:1), and 0.75 bpp (16:1). Two randomly selected slices from each examination were shown to observers using a flicker mode paradigm in which observers rapidly toggled between two images, the original and a compressed version, with the task of deciding whether differences between them could be detected. Six staff radiologists, four residents, and six PhDs experienced in medical imaging (from three institutions) served as observers. Overall, 77.46% of observers detected differences at 8:1, 94.75% at 12:1, and 98.59% at 16:1 compression levels. Across all compression levels, the staff radiologists noted differences 64.70% of the time, the resident's detected differences 71.91% of the time, and the PhDs detected differences 69.95% of the time. Even mild compression is perceptible with current technology. The ability to detect differences does not equate to diagnostic differences, although perception of compression artifacts could affect diagnostic decision making and diagnostic workflow.
Kucmin, Tomasz; Płowaś-Goral, Małgorzata; Nogalski, Adam
2015-02-01
Cardiopulmonary resuscitation (CPR) is relatively novel branch of medical science, however first descriptions of mouth-to-mouth ventilation are to be found in the Bible and literature is full of descriptions of different resuscitation methods - from flagellation and ventilation with bellows through hanging the victims upside down and compressing the chest in order to stimulate ventilation to rectal fumigation with tobacco smoke. The modern history of CPR starts with Kouwenhoven et al. who in 1960 published a paper regarding heart massage through chest compressions. Shortly after that in 1961Peter Safar presented a paradigm promoting opening the airway, performing rescue breaths and chest compressions. First CPR guidelines were published in 1966. Since that time guidelines were modified and improved numerously by two leading world expert organizations ERC (European Resuscitation Council) and AHA (American Heart Association) and published in a new version every 5 years. Currently 2010 guidelines should be obliged. In this paper authors made an attempt to present history of development of resuscitation techniques and methods and assess the influence of previous lifesaving methods on nowadays technologies, equipment and guidelines which allow to help those women and men whose life is in danger due to sudden cardiac arrest. © 2015 MEDPRESS.
A better understanding of ambulance personnel's attitude towards real-time resuscitation feedback.
Brinkrolf, Peter; Lukas, Roman; Harding, Ulf; Thies, Sebastian; Gerss, Joachim; Van Aken, Hugo; Lemke, Hans; Schniedermeier, Udo; Bohn, Andreas
2018-03-01
High-quality chest compressions during cardiopulmonary resuscitation (CPR) play a significant role in surviving cardiac arrest. Chest-compression quality can be measured and corrected by real-time CPR feedback devices, which are not yet commonly used. This article looks at the acceptance of such systems in comparison of equipped and unequipped personnel. Two groups of emergency medical services' (EMS) personnel were interviewed using standardized questionnaires. The survey was conducted in the German cities Dortmund and Münster. Overall, 205 persons participated in the survey: 103 paramedics and emergency physicians from the Dortmund fire service and 102 personnel from the Münster service. The staff of the Dortmund service were not equipped with real-time feedback systems. The test group of equipped personnel of the ambulance service of Münster Fire brigade uses real-time feedback systems since 2007. What is the acceptance level of real-time feedback systems? Are there differences between equipped and unequipped personnel? The total sample is receptive towards real-time feedback systems. More than 80% deem the system useful. However, this study revealed concerns and prejudices by unequipped personnel. Negative ratings are significantly lower at the Münster site that is experienced with the use of the real-time feedback system in contrast to the Dortmund site where no such experience exists-the system's use in daily routine results in better evaluation than the expectations of unequipped personnel. Real-time feedback systems receive overall positive ratings. Prejudices and concerns seem to decrease with continued use of the system.
The effects of an online basic life support course on undergraduate nursing students' learning.
Tobase, Lucia; Peres, Heloisa H C; Gianotto-Oliveira, Renan; Smith, Nicole; Polastri, Thatiane F; Timerman, Sergio
2017-08-25
To describe learning outcomes of undergraduate nursing students following an online basic life support course (BLS). An online BLS course was developed and administered to 94 nursing students. Pre- and post-tests were used to assess theoretical learning. Checklist simulations and feedback devices were used to assess the cardiopulmonary resuscitation (CPR) skills of the 62 students who completed the course. A paired t-test revealed a significant increase in learning [pre-test (6.4 ± 1.61), post-test (9.3 ± 0.82), p < 0.001]. The increase in the average grade after taking the online course was significant (p<0.001). No learning differences (p=0.475) had been observed between 1st and 2nd year (9.20 ± 1.60), and between 3rd and 4th year (9.67 ± 0.61) students. A CPR simulation was performed after completing the course: students checked for a response (90%), exposed the chest (98%), checked for breathing (97%), called emergency services (76%), requested for a defibrillator (92%), checked for a pulse (77%), positioned their hands properly (87%), performed 30 compressions/cycle (95%), performed compressions of at least 5 cm depth (89%), released the chest (90%), applied two breaths (97%), used the automated external defibrillator (97%), and positioned the pads (100%). The online course was an effective method for teaching and learning key BLS skills wherein students were able to accurately apply BLS procedures during the CPR simulation. This short-term online training, which likely improves learning and self-efficacy in BLS providers, can be used for the continuing education of health professionals.
A chest drainage system with a real-time pressure monitoring device
Liu, Tsang-Pai; Huang, Tung-Sung; Liu, Hung-Chang; Chen, Chao-Hung
2015-01-01
Background Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the “tidaling phenomenon” in the bottle can be reflective of the extent of patient’s recovery. Objectives However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube. Methods The device is made of a pressure sensor with an operating range between −100 to +100 cmH2O and an amplifying using the “Wheatstone bridge” concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector. Results The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O. Conclusions This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system. PMID:26380726
A chest drainage system with a real-time pressure monitoring device.
Chen, Chih-Hao; Liu, Tsang-Pai; Chang, Ho; Huang, Tung-Sung; Liu, Hung-Chang; Chen, Chao-Hung
2015-07-01
Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the "tidaling phenomenon" in the bottle can be reflective of the extent of patient's recovery. However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube. The device is made of a pressure sensor with an operating range between -100 to +100 cmH2O and an amplifying using the "Wheatstone bridge" concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector. The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O. This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system.
Bradley, Matthew J; Bonds, Brandon W; Chang, Luke; Yang, Shiming; Hu, Peter; Li, Hsiao-Chi; Brenner, Megan L; Scalea, Thomas M; Stein, Deborah M
2016-11-01
Open chest cardiac massage (OCCM) is a commonly performed procedure after traumatic cardiac arrest (TCA). OCCM has been reported to be superior to closed chest compressions (CCC) in animal models and in non-TCA. The purpose of this study is to prospectively compare OCCM versus CCC in TCA using end-tidal carbon dioxide (ETCO2), the criterion standard for determining the effectiveness of chest compressions and detection of return of spontaneous circulation (ROSC), as the surrogate for cardiac output and marker for adequacy of resuscitation. This prospective observational study enrolled patients over a 9-month period directly presenting to a level 1 trauma center after TCA. Continuous high-resolution ETCO2 measurements were collected every 6 seconds for periods of CCC and OCCM, respectively. Patients receiving CCC only were compared with patients receiving CCC followed by OCCM. Student's t tests were used to compare ETCO2 within and between groups. Thirty-three patients were enrolled (16 OCCM, 17 CCC-only). Mean time of CCC before OCCM was 66 seconds. Within the OCCM group, final, peak, mean, and median ETCO2 levels significantly increased when comparing the initial CCC period to the OCCM interval. Using a time-matched comparison, significant increases were observed in the final and peak but not mean and median values when comparing the first minute of CCC to the remaining time in the CCC-only group. However, when periods of OCCM were compared with equivalent periods of CCC-only, there were no differences in the initial, final, peak, mean, or median ETCO2 values. Correspondingly, no difference in rates of ROSC was observed between groups (OCCM 23.5% vs. CCC 38.9%; p = 0.53). Although we could not control for confounders, we found no significant improvement in ETCO2 or ROSC with OCCM. With newer endovascular techniques for aortic occlusion, thoracotomy solely for performing OCCM provides no benefit over CCC. Therapeutic study, level III.
Pan, Jian; Zhu, Jian-Yong; Kee, Ho Sen; Zhang, Qing; Lu, Yuan-Qiang
2015-01-01
Objective: Important studies of cardiopulmonary resuscitation (CPR) techniques influence the development of new guidelines. We systematically reviewed the efficacy of some important studies of CPR. Data Sources: The data analyzed in this review are mainly from articles included in PubMed and EMBASE, published from 1964 to 2014. Study Selection: Original articles and critical reviews about CPR techniques were selected for review. Results: The survival rate after out-of-hospital cardiac arrest (OHCA) is improving. This improvement is associated with the performance of uninterrupted chest compressions and simple airway management procedures during bystander CPR. Real-time feedback devices can be used to improve the quality of CPR. The recommended dose, timing, and indications for adrenaline (epinephrine) use may change. The appropriate target temperature for targeted temperature management is still unclear. Conclusions: New studies over the past 5 years have evaluated various aspects of CPR in OHCA. Some of these studies were high-quality randomized controlled trials, which may help to improve the scientific understanding of resuscitation techniques and result in changes to CPR guidelines. PMID:25673462
Management of chest drainage tubes after lung surgery.
Satoh, Yukitoshi
2016-06-01
Since chest tubes have been routinely used to drain the pleural space, particularly after lung surgery, the management of chest tubes is considered to be essential for the thoracic surgeon. The pleural drainage system requires effective drainage, suction, and water-sealing. Another key point of chest tube management is that a water seal is considered to be superior to suction for most air leaks. Nowadays, the most common pleural drainage device attached to the chest tube is the three-bottle system. An electronic chest drainage system has been developed that is effective in standardizing the postoperative management of chest tubes. More liberal use of digital drainage devices in the postoperative management of the pleural space is warranted. The removal of chest tubes is a common procedure occurring almost daily in hospitals throughout the world. Extraction of the tube is usually done at the end of full inspiration or at the end of full expiration. The tube removal technique is not as important as how it is done and the preparation for the procedure. The management of chest tubes must be based on careful observation, the patient's characteristics, and the operative procedures that had been performed.
Delivery of cardiopulmonary resuscitation in the microgravity environment
NASA Technical Reports Server (NTRS)
Barratt, M. R.; Billica, R. D.
1992-01-01
The microgravity environment presents several challenges for delivering effective cardiopulmonary resuscitation (CPR). Chest compressions must be driven by muscular force rather than by the weight of the rescuer's upper torso. Airway stabilization is influenced by the neutral body posture. Rescuers will consist of crew members of varying sizes and degrees of physical deconditioning from space flight. Several methods of CPR designed to accommodate these factors were tested in the one G environment, in parabolic flight, and on a recent shuttle flight. Methods: Utilizing study participants of varying sizes, different techniques of CPR delivery were evaluated using a recording CPR manikin to assess adequacy of compressive force and frequency. Under conditions of parabolic flight, methods tested included conventional positioning of rescuer and victim, free floating 'Heimlich type' compressions, straddling the patient with active and passive restraints, and utilizing a mechanical cardiac compression assist device (CCAD). Multiple restrain systems and ventilation methods were also assessed. Results: Delivery of effective CPR was possible in all configurations tested. Reliance on muscular force alone was quickly fatiguing to the rescuer. Effectiveness of CPR was dependent on technique, adequate restraint of the rescuer and patient, and rescuer size and preference. Free floating CPR was adequate but rapidly fatiguing. The CCAD was able to provide adequate compressive force but positioning was problematic. Conclusions: Delivery of effective CPR in microgravity will be dependent on adequate resuer and patient restraint, technique, and rescuer size and preference. Free floating CPR may be employed as a stop gap method until patient restraint is available. Development of an adequate CCAD would be desirable to compensate for the effects of deconditioning.
Method and apparatus for holding two separate metal pieces together for welding
NASA Technical Reports Server (NTRS)
Mcclure, S. R. (Inventor)
1980-01-01
A method of holding two separate metal pieces together for welding is described including the steps of overlapping a portion of one of the metal pieces on a portion of the other metal piece, encasing the overlapping metal piece in a compressible device, drawing the compressible device into an enclosure, and compressing a portion of the compressible device around the overlapping portions of the metal pieces for holding the metal pieces under constant and equal pressure during welding. The preferred apparatus for performing the method utilizes a support mechanism to support the two separate metal pieces in an overlapping configuration; a compressible device surrounding the support mechanism and at least one of the metal pieces, and a compressing device surrounding the compressible device for compressing the compressible device around the overlapping portions of the metal pieces, thus providing constant and equal pressure at all points on the overlapping portions of the metal pieces.
Ahmed, Niloy; Carlos, Morales-Mangual; Moshe, Gunsburg; Yitzhak, Rosen
2016-01-01
This case report describes a patient who developed palpitations and chest pain and was found to be in atrial fibrillation, which was likely due to the presence of an extra-cardiac mass. This was compressing the left atrium. The mass was related to small cell carcinoma, which decreased significantly in size after chemotherapy. Resolution of the atrial fibrillation correlated temporally with reduction in the size of the mass and alleviation of the left atrial compression.
Total artificial heart in the pediatric patient with biventricular heart failure.
Park, S S; Sanders, D B; Smith, B P; Ryan, J; Plasencia, J; Osborn, M B; Wellnitz, C M; Southard, R N; Pierce, C N; Arabia, F A; Lane, J; Frakes, D; Velez, D A; Pophal, S G; Nigro, J J
2014-01-01
Mechanical circulatory support emerged for the pediatric population in the late 1980s as a bridge to cardiac transplantation. The Total Artificial Heart (TAH-t) (SynCardia Systems Inc., Tuscon, AZ) has been approved for compassionate use by the Food and Drug Administration for patients with end-stage biventricular heart failure as a bridge to heart transplantation since 1985 and has had FDA approval since 2004. However, of the 1,061 patients placed on the TAH-t, only 21 (2%) were under the age 18. SynCardia Systems, Inc. recommends a minimum patient body surface area (BSA) of 1.7 m(2), thus, limiting pediatric application of this device. This unique case report shares this pediatric institution's first experience with the TAH-t. A 14-year-old male was admitted with dilated cardiomyopathy and severe biventricular heart failure. The patient rapidly decompensated, requiring extracorporeal life support. An echocardiogram revealed severe biventricular dysfunction and diffuse clot formation in the left ventricle and outflow tract. The decision was made to transition to biventricular assist device. The biventricular failure and clot formation helped guide the team to the TAH-t, in spite of a BSA (1.5 m(2)) below the recommendation of 1.7 m(2). A computed tomography (CT) scan of the thorax, in conjunction with a novel three-dimensional (3D) modeling system and team, assisted in determining appropriate fit. Chest CT and 3D modeling following implantation were utilized to determine all major vascular structures were unobstructed and the bronchi were open. The virtual 3D model confirmed appropriate device fit with no evidence of compression to the left pulmonary veins. The postoperative course was complicated by a left lung opacification. The left lung anomalies proved to be atelectasis and improved with aggressive recruitment maneuvers. The patient was supported for 11 days prior to transplantation. Chest CT and 3D modeling were crucial in assessing whether the device would fit, as well as postoperative complications in this smaller pediatric patient.
Chest compressions in newborn animal models: A review.
Solevåg, Anne Lee; Cheung, Po-Yin; Lie, Helene; O'Reilly, Megan; Aziz, Khalid; Nakstad, Britt; Schmölzer, Georg Marcus
2015-11-01
Much of the knowledge about the optimal way to perform chest compressions (CC) in newborn infants is derived from animal studies. The objective of this review was to identify studies of CC in newborn term animal models and review the evidence. We also provide an overview of the different models. MEDLINE, EMBASE and CINAHL, until September 29th 2014. Study eligibility criteria and interventions: term newborn animal models where CC was performed. Based on 419 retrieved studies from MEDLINE and 502 from EMBASE, 28 studies were included. No additional studies were identified in CINAHL. Most of the studies were performed in pigs after perinatal transition without long-term follow-up. The models differed widely in methodological aspects, which limits the possibility to compare and synthesize findings. Studies uncommonly reported the method for randomization and allocation concealment, and a limited number were blinded. Only the evidence in favour of the two-thumb encircling hands technique for performing CC, a CC to ventilation ratio of 3:1; and that air can be used for ventilation during CC; was supported by more than one study. Animal studies should be performed and reported with the same rigor as in human randomized trials. Good transitional and survival models are needed to further increase the strength of the evidence derived from animal studies of newborn chest compressions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Amnuaypattanapon, Kumpol; Udomsubpayakul, Umaporn
2010-12-01
In the present study, we aimed to define the factors contributing to patient survival after treatment by cardiopulmonary resuscitation (CPR) following cardiac arrest. Retrospective analysis was performed on cardiac arrest patients (n=138) who had CPR in the emergency department (ED) at Thammasat University hospital from 2007-2009. Logistic regression was used to analyze factors that related to the sustained return of spontaneous circulation (ROSC) for 20 minutes, survival until discharge, and survival up to 1 month post discharge. The sustained ROSC was 22.5%, survival to discharge 5.6%, and survival from discharge to 1 month 3.6%. Significant factors related to sustained ROSC was the location of cardiac arrest, the cause of arrest, shockable rhythm with defibrillation, the time until chest compression, and CPR duration. The factor influencing survival to discharge was chest compression performed within 15 minutes after cardiac arrest (p = 0.048). No factor however could be attributed to survivability up to 1 month following discharge. Our findings attribute six factors associated to ROSC including the location of arrest, the cause of cardiac arrest, initial cardiac rhythm, shockable rhythm with defibrillation, the time until chest compression and CPR duration. Statistically, resuscitation performed within 15 minutes of cardiac arrest increases the survivability of patients until discharge. However no factors could be related to the percentage of patients surviving up to 1 month post discharge.
CPR - child (1 to 8 years old)
Rescue breathing and chest compressions - child; Resuscitation - cardiopulmonary - child; Cardiopulmonary resuscitation - child ... take care of children should learn infant and child CPR if they have not already. See www. ...
Using ontologies to integrate and share resuscitation data from diverse medical devices.
Thorsen, Kari Anne Haaland; Eftestøl, Trygve; Tøssebro, Erlend; Rong, Chunming; Steen, Petter Andreas
2009-05-01
To propose a method for standardised data representation and demonstrate a technology that makes it possible to translate data from device dependent formats to this standard representation format. Outcome statistics vary between emergency medical systems organising resuscitation services. Such differences indicate a potential for improvement by identifying factors affecting outcome, but data subject to analysis have to be comparable. Modern technology for communicating information makes it possible to structure, store and transfer data flexibly. Ontologies describe entities in the world and how they relate. Letting different computer systems refer to the same ontology results in a common understanding on data content. Information on therapy such as shock delivery, chest compressions and ventilation should be defined and described in a standardised ontology to enable comparison and combining data from diverse sources. By adding rules and logic data can be merged and combined in new ways to produce new information. An example ontology is designed to demonstrate the feasibility and value of such a standardised structure. The proposed technology makes possible capturing and storing of data from different devices in a structured and standardised format. Data can easily be transformed to this standardised format, compared and combined independent of the original structure.
McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E
2011-12-01
Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (P<0.001), whereas TPV compression (P=0.01) and apposition to the anterior chest wall (P=0.02) were associated with shorter freedom from MSF. Freedom from RVOT reintervention was 86±4% at 27 months. Among patients with a MSF, freedom from RVOT reintervention after MSF diagnosis was 49±10% at 2 years. Factors associated with reintervention were similar to those for MSF. MSF was common after TPV implant in this multicenter experience and was more likely in patients with severely obstructed RVOT conduits and when the TPV was directly behind the anterior chest wall and/or clearly compressed. A TPV implant site protected by a prestent or bioprosthetic valve was associated with lower risk of MSF and reintervention.
The effects of an online basic life support course on undergraduate nursing students’ learning
Tobase, Lucia; Peres, Heloisa H.C.; Smith, Nicole; Polastri, Thatiane F.; Timerman, Sergio
2017-01-01
Objectives To describe learning outcomes of undergraduate nursing students following an online basic life support course (BLS). Methods An online BLS course was developed and administered to 94 nursing students. Pre- and post-tests were used to assess theoretical learning. Checklist simulations and feedback devices were used to assess the cardiopulmonary resuscitation (CPR) skills of the 62 students who completed the course. Results A paired t-test revealed a significant increase in learning [pre-test (6.4 ± 1.61), post-test (9.3 ± 0.82), p < 0.001]. The increase in the average grade after taking the online course was significant (p<0.001). No learning differences (p=0.475) had been observed between 1st and 2nd year (9.20 ± 1.60), and between 3rd and 4th year (9.67 ± 0.61) students. A CPR simulation was performed after completing the course: students checked for a response (90%), exposed the chest (98%), checked for breathing (97%), called emergency services (76%), requested for a defibrillator (92%), checked for a pulse (77%), positioned their hands properly (87%), performed 30 compressions/cycle (95%), performed compressions of at least 5 cm depth (89%), released the chest (90%), applied two breaths (97%), used the automated external defibrillator (97%), and positioned the pads (100%). Conclusions The online course was an effective method for teaching and learning key BLS skills wherein students were able to accurately apply BLS procedures during the CPR simulation. This short-term online training, which likely improves learning and self-efficacy in BLS providers, can be used for the continuing education of health professionals. PMID:28850944
Digital and smart chest drainage systems to monitor air leaks: the birth of a new era?
Cerfolio, Robert J; Varela, Gonzalo; Brunelli, Alessandro
2010-08-01
Recently, several companies have manufactured and commercialized new pleural drainage units that incorporate electronic components for the digital quantification of air through chest tubes and, in some instances, pleural pressure assessment. The goal of these systems is to objectify this previously subjective bedside clinical parameter and allow for more objective, consistent measurement of air leaks. The belief is this will lead to quicker and more accurate chest tube management. In addition, some systems feature portable suction devices. These may afford earlier mobilization of patients because the pleural drainage chamber is attached to a battery-powered smart suction device. In this article we review the clinical experiences using these new devices. Copyright 2010 Elsevier Inc. All rights reserved.
Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Cho, Young Soon; Chung, Sung Phil; Park, Incheol; Kim, Seung Ho
2012-12-01
Metronome guidance is a simple and economic feedback method of guiding cardiopulmonary resuscitation (CPR). It has been proven for its usefulness in regulating the rate of chest compression and ventilation, but it is not yet clear how metronome use may affect compression depth or rescuer fatigue. The aim of this study was to assess the specific effect that metronome guidance has on the quality of CPR and rescuer fatigue. One-person CPRs were performed by senior medical students on Resusci Anne® manikins (Laerdal, Stavanger, Norway) with personal-computer skill-reporting systems. Half of the students performed CPR with metronome guidance and the other half without. CPR performance data, duration, and before-after trial differences in mean arterial pressure (MAP) and heart rate (HR) were compared between groups. Average compression depth (ACD) of the first five cycles, compression rate, no-flow fraction, and ventilation count were significantly lower in the metronome group (p=0.028, < 0.001, 0.001, and 0.041, respectively). Total CPR duration, total work (ACD × total compression count), and the before-after trial differences of the MAP and HR did not differ between the two groups. Metronome guidance is associated with lower chest compression depth of the first five cycles, while shortening the no-flow fraction and the ventilation count in a simulated one-person CPR model. Metronome guidance does not have an obvious effect of intensifying rescuer fatigue. Copyright © 2012 Elsevier Inc. All rights reserved.
[A first step to teaching basic life support in schools: Training the teachers].
Pichel López, María; Martínez-Isasi, Santiago; Barcala-Furelos, Roberto; Fernández-Méndez, Felipe; Vázquez Santamariña, David; Sánchez-Santos, Luis; Rodríguez-Nuñez, Antonio
2017-12-07
Teachers may have an essential role in basic life support (BLS) training in schoolchildren. However, few data are available about their BLS learning abilities. To quantitatively assess the quality of BLS when performed by school teachers after a brief and simple training program. A quasi-experimental study with no control group, and involving primary and secondary education teachers from four privately managed and public funded schools was conducted in 3 stages: 1st. A knowledge test, 2nd: BLS training, and 3rd: Performance test. Training included a 40minutes lecture and 80minutes hands-on session with the help feedback on the quality of the chest compressions. A total of 81 teachers were included, of which 60.5% were women. After training, the percentage of subjects able to perform the BLS sequence rose from 1.2% to 46% (P<.001). Chest compression quality also improved significantly in terms of: correct hands position (97.6 vs. 72.3%; P<.001), mean depth (48.1 vs. 38.8mm; P<.001), percentage that reached recommended depth (46.5 vs. 21.5%; P<.001), percentage of adequate decompression (78.7 vs. 61.2%; P<.05), and percentage of compressions delivered at recommended rate (64.2 vs. 26.9%; P<.001). After and brief and simple training program, teachers of privately managed public funded schools were able to perform the BLS sequence and to produce chest compressions with a quality similar to that obtained by staff with a duty to assist cardiac arrest victims. The ability of schoolteachers to deliver good-quality BLS is a pre-requisite to be engaged in BLS training for schoolchildren. Copyright © 2017. Publicado por Elsevier España, S.L.U.
NASA Astrophysics Data System (ADS)
Rodríguez-Ruiz, Alejandro; Agasthya, Greeshma A.; Sechopoulos, Ioannis
2017-09-01
To characterize and develop a patient-based 3D model of the compressed breast undergoing mammography and breast tomosynthesis. During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3D breast surface imaging with structured light (SL) during breast compression, along with simultaneous acquisition of a tomosynthesis image. A pair of SL systems were used to acquire 3D surface images by projecting 24 different patterns onto the compressed breast and capturing their reflection off the breast surface in approximately 12-16 s. The 3D surface was characterized and modeled via principal component analysis. The resulting surface model was combined with a previously developed 2D model of projected compressed breast shapes to generate a full 3D model. Data from ten patients were discarded due to technical problems during image acquisition. The maximum breast thickness (found at the chest-wall) had an average value of 56 mm, and decreased 13% towards the nipple (breast tilt angle of 5.2°). The portion of the breast not in contact with the compression paddle or the support table extended on average 17 mm, 18% of the chest-wall to nipple distance. The outermost point along the breast surface lies below the midline of the total thickness. A complete 3D model of compressed breast shapes was created and implemented as a software application available for download, capable of generating new random realistic 3D shapes of breasts undergoing compression. Accurate characterization and modeling of the breast curvature and shape was achieved and will be used for various image processing and clinical tasks.
Metronome improves compression and ventilation rates during CPR on a manikin in a randomized trial.
Kern, Karl B; Stickney, Ronald E; Gallison, Leanne; Smith, Robert E
2010-02-01
We hypothesized that a unique tock and voice metronome could prevent both suboptimal chest compression rates and hyperventilation. A prospective, randomized, parallel design study involving 34 pairs of paid firefighter/emergency medical technicians (EMTs) performing two-rescuer CPR using a Laerdal SkillReporter Resusci Anne manikin with and without metronome guidance was performed. Each CPR session consisted of 2 min of 30:2 CPR with an unsecured airway, then 4 min of CPR with a secured airway (continuous compressions at 100 min(-1) with 8-10 ventilations/min), repeated after the rescuers switched roles. The metronome provided "tock" prompts for compressions, transition prompts between compressions and ventilations, and a spoken "ventilate" prompt. During CPR with a bag/valve/mask the target compression rate of 90-110 min(-1) was achieved in 5/34 CPR sessions (15%) for the control group and 34/34 sessions (100%) for the metronome group (p<0.001). An excessive ventilation rate was not observed in either the metronome or control group during CPR with a bag/valve/mask. During CPR with a bag/endotracheal tube, the target of both a compression rate of 90-110 min(-1) and a ventilation rate of 8-11 min(-1) was achieved in 3/34 CPR sessions (9%) for the control group and 33/34 sessions (97%) for the metronome group (p<0.001). Metronome use with the secured airway scenario significantly decreased the incidence of over-ventilation (11/34 EMT pairs vs. 0/34 EMT pairs; p<0.001). A unique combination tock and voice prompting metronome was effective at directing correct chest compression and ventilation rates both before and after intubation. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
van Tulder, Raphael; Roth, Dominik; Krammel, Mario; Laggner, Roberta; Schriefl, Christoph; Kienbacher, Calvin; Lorenzo Hartmann, Alexander; Novosad, Heinz; Constantin Chwojka, Christof; Havel, Christoph; Schreiber, Wolfgang; Herkner, Harald
2015-01-01
We investigated the effect on compression rate and depth of a conventional metronome and a voice metronome in simulated telephone-assisted, protocol-driven bystander Cardiopulmonary resucitation (CPR) compared to standard instruction. Thirty-six lay volunteers performed 10 minutes of compression-only CPR in a prospective, investigator-blinded, 3-arm study on a manikin. Participants were randomized either to standard instruction ("push down firmly, 5 cm"), a regular metronome pacing 110 beats per minute (bpm), or a voice metronome continuously prompting "deep-deepdeep- deeper" at 110 bpm. The primary outcome was deviation from the ideal chest compression target range (50 mm compression depth x 100 compressions per minute x 10 minutes = 50 m). Secondary outcomes were CPR quality measures (compression and leaning depth, rate, no-flow times) and participants' related physiological response (heart rate, blood pressure and nine hole peg test and borg scales score). We used a linear regression model to calculate effects. The mean (SD) deviation from the ideal target range (50 m) was -11 (9) m in the standard group, -20 (11) m in the conventional metronome group (adjusted difference [95%, CI], 9.0 [1.2-17.5 m], P=.03), and -18 (9) m in the voice metronome group (adjusted difference, 7.2 [-0.9-15.3] m, P=.08). Secondary outcomes (CPR quality measures and physiological response of participants to CPR performance) showed no significant differences. Compared to standard instruction, the conventional metronome showed a significant negative effect on the chest compression target range. The voice metronome showed a non-significant negative effect and therefore cannot be recommended for regular use in telephone-assisted CPR.
Optical Fiber Sensors For Monitoring Joint Articulation And Chest Expansion Of A Human Body
Muhs, Jeffrey D.; Allison, Stephen W.
1997-12-23
Fiber-optic sensors employing optical fibers of elastomeric material are incorporated in devices adapted to be worn by human beings in joint and chest regions for the purpose of monitoring and measuring the extent of joint articulation and chest expansion especially with respect to time.
Modern BLS, dispatch and AED concepts.
Koster, Rudolph W
2013-09-01
Basic Life Support has changed significantly over the last 15 years. Evidence-based changes in recommendations involved compression rate, compression depth and the ratio between compressions and ventilations. There is much evidence that early basic life support increases the probability of survival two- to three-fold. Recognition of a cardiac arrest remains challenging for witness and dispatcher. Educating the public in basic life support and recognition of cardiac arrest are key factors in improving survival of cardiac arrest. The large differences in survival between countries and regions clearly indicate that education and implementation must be high on the agenda in each community. Dispatchers play an increasingly important role in the process, both in rapid recognition of the cardiac arrest as well as giving telephone guidance to those bystanders that had not followed a training in basic life support. Those instructions should only instruct to deliver chest compressions. For those who have been trained in BLS and who are willing to give full CPR, should administer ventilations and chest compressions according to the guidelines. The AED plays a key role in early management of cardiac arrest and can substantially contribute to better survival. Logistics of placement of AEDs and the optimal way to bring AEDs to a victim require much more efforts, especially for victims in residential area's, where the great majority of cases of cardiac arrest occur. Copyright © 2013 Elsevier Ltd. All rights reserved.
[Pectus excavatumn and carinatum in children and adolescents : what to say, what to do ?
Lascombes, Pierre; Ruchonnet-Métrailler, Isabelle; Beghetti, Maurice; Bottani, Armand; Wilde, James
2017-02-15
In children presenting with a pectus excavatum (PE) or pectus carinatum (PC) an underlying syndrome including Marfan's syndrome needs to be excluded. In adolescents, severe chest wall deformities may cause cardiac or respiratory problems but most commonly they have a psychological impact. The conservative treatment is a Vacuum Bell for PE, and a Dynamic Compression System for PC ; they play an increasing role in young patients. These devices need to be worn multiple hours per day for several months for an optimal result. Surgery is usually reserved for adolescents. The Nuss procedure for PE, also known as minimal invasive repair of PE offers excellent results. Sterno-chondro-plasty with stabilisation of the sternum with struts clipped to the ribs offers the same good results for PC. In our opinion, a multidisciplinary approach is preferable.
Somers, Jeffrey T.; Newby, Nathaniel; Lawrence, Charles; DeWeese, Richard; Moorcroft, David; Phelps, Shean
2014-01-01
The objective of this study was to investigate new methods for predicting injury from expected spaceflight dynamic loads by leveraging a broader range of available information in injury biomechanics. Although all spacecraft designs were considered, the primary focus was the National Aeronautics and Space Administration Orion capsule, as the authors have the most knowledge and experience related to this design. The team defined a list of critical injuries and selected the THOR anthropomorphic test device as the basis for new standards and requirements. In addition, the team down-selected the list of available injury metrics to the following: head injury criteria 15, kinematic brain rotational injury criteria, neck axial tension and compression force, maximum chest deflection, lateral shoulder force and displacement, acetabular lateral force, thoracic spine axial compression force, ankle moments, and average distal forearm speed limits. The team felt that these metrics capture all of the injuries that might be expected by a seated crewmember during vehicle aborts and landings. Using previously determined injury risk levels for nominal and off-nominal landings, appropriate injury assessment reference values (IARVs) were defined for each metric. Musculoskeletal deconditioning due to exposure to reduced gravity over time can affect injury risk during landing; therefore a deconditioning factor was applied to all IARVs. Although there are appropriate injury data for each anatomical region of interest, additional research is needed for several metrics to improve the confidence score. PMID:25152879
Tricuspid valve chordal rupture due to airbag injury and review of pathophysiological mechanisms.
Thekkudan, Joyce; Luckraz, Heyman; Ng, Alex; Norell, Mike
2012-09-01
Blunt trauma to the chest is associated with significant morbidity and mortality. The latter is usually due to an aortic transection, whereas the former is related to myocardial contusion, cardiac valve injury, coronary artery disruption and intracardiac shunts due to the formation of septal defects. The main mechanisms causing these injuries are due to the sudden deceleration force and compression within the chest cavity. Moreover, there is also the sudden increase in intravascular pressure due to a mechanical compression effect and a hormonal adrenergic surge during the event. We report a case of a tricuspid valve injury caused by the deployment of the airbag during a high-speed impact car accident and the subsequent damage to the tricuspid valve chordal mechanism. The patient's management and the pathophysiological mechanisms involved in the injury are reviewed.
Junior physician skill and behaviour in resuscitation: a simulation study.
Høyer, Christian Bjerre; Christensen, Erika F; Eika, Berit
2009-02-01
Physicians are expected to manage their role as teamleader during resuscitation. During inter-hospital transfer the physician has the highest medical credentials on a small team. The aim of this study was to describe physician behaviour as teamleaders in a simulated cardiac arrest during inter-hospital transfer. Our goal was to pinpoint deficits in knowledge and skill integration and make recommendations for improvements in education. An ambulance was the framework for the simulation; the scenario a patient with acute coronary syndrome suffering ventricular fibrillation during transportation. Physicians (graduation age < or =5 years) working in internal medicine departments in Denmark were studied. The ambulance crew was instructed to be passive to clarify the behaviour of the physicians. 72 physicians were studied. Chest compressions were initiated in 71 cases, ventilation and defibrillation in 72. The median times for arrival of the driver in the patient cabin, initiation of ventilation and chest compressions, and first defibrillation were all less than 1min. Medication was administered in 63/72 simulations (88%), after a median time of 210 s. Adrenaline was the preferred initial drug administered (58/63, 92%). Tasks delegated were ventilations, chest compressions, defibrillation, and administration of medication (97%, 92%, 42%, and 10% of cases, respectively). Junior physicians performed well with respect to the treatment given and the delegation of tasks. However, variations in the time of initiation it took for each treatment indicated lack of leadership skills. It is imperative that the education of physicians includes training in leadership.
Active cycle of breathing technique for cystic fibrosis.
Mckoy, Naomi A; Wilson, Lisa M; Saldanha, Ian J; Odelola, Olaide A; Robinson, Karen A
2016-07-05
People with cystic fibrosis experience chronic airway infections as a result of mucus build up within the lungs. Repeated infections often cause lung damage and disease. Airway clearance therapies aim to improve mucus clearance, increase sputum production, and improve airway function. The active cycle of breathing technique (also known as ACBT) is an airway clearance method that uses a cycle of techniques to loosen airway secretions including breathing control, thoracic expansion exercises, and the forced expiration technique. This is an update of a previously published review. To compare the clinical effectiveness of the active cycle of breathing technique with other airway clearance therapies in cystic fibrosis. We searched the Cochrane Cystic Fibrosis Trials Register, compiled from electronic database searches and handsearching of journals and conference abstract books. We also searched the reference lists of relevant articles and reviews.Date of last search: 25 April 2016. Randomised or quasi-randomised controlled clinical studies, including cross-over studies, comparing the active cycle of breathing technique with other airway clearance therapies in cystic fibrosis. Two review authors independently screened each article, abstracted data and assessed the risk of bias of each study. Our search identified 62 studies, of which 19 (440 participants) met the inclusion criteria. Five randomised controlled studies (192 participants) were included in the meta-analysis; three were of cross-over design. The 14 remaining studies were cross-over studies with inadequate reports for complete assessment. The study size ranged from seven to 65 participants. The age of the participants ranged from six to 63 years (mean age 22.33 years). In 13 studies, follow up lasted a single day. However, there were two long-term randomised controlled studies with follow up of one to three years. Most of the studies did not report on key quality items, and therefore, have an unclear risk of bias in terms of random sequence generation, allocation concealment, and outcome assessor blinding. Due to the nature of the intervention, none of the studies blinded participants or the personnel applying the interventions. However, most of the studies reported on all planned outcomes, had adequate follow up, assessed compliance, and used an intention-to-treat analysis.Included studies compared the active cycle of breathing technique with autogenic drainage, airway oscillating devices, high frequency chest compression devices, conventional chest physiotherapy, and positive expiratory pressure. Preference of technique varied: more participants preferred autogenic drainage over the active cycle of breathing technique; more preferred the active cycle of breathing technique over airway oscillating devices; and more were comfortable with the active cycle of breathing technique versus high frequency chest compression. No significant difference was seen in quality of life, sputum weight, exercise tolerance, lung function, or oxygen saturation between the active cycle of breathing technique and autogenic drainage or between the active cycle of breathing technique and airway oscillating devices. There was no significant difference in lung function and the number of pulmonary exacerbations between the active cycle of breathing technique alone or in conjunction with conventional chest physiotherapy. All other outcomes were either not measured or had insufficient data for analysis. There is insufficient evidence to support or reject the use of the active cycle of breathing technique over any other airway clearance therapy. Five studies, with data from eight different comparators, found that the active cycle of breathing technique was comparable with other therapies in outcomes such as participant preference, quality of life, exercise tolerance, lung function, sputum weight, oxygen saturation, and number of pulmonary exacerbations. Longer-term studies are needed to more adequately assess the effects of the active cycle of breathing technique on outcomes important for people with cystic fibrosis such as quality of life and preference.
Robak, A N
2008-11-01
A new method for the formation of a compression esophagointestinal anastomosis is proposed. The compression force in the new device for creation of compression circular anastomoses is created by means of a titanium nickelide spring with a "shape memory" effect. Experimental study showed good prospects of the new device and the advantages of the anastomosis compression suture formed by means of this device in comparison with manual ligature suturing.
Dohi, Satoshi; Ichizuka, Kiyotake; Matsuoka, Ryu; Seo, Kohei; Nagatsuka, Masaaki; Sekizawa, Akihiko
2017-09-01
The risk of maternal and fetal mortality is high if cardiopulmonary arrest occurs during pregnancy. To assess the best position for maternal cardiopulmonary resuscitation (CPR), a prospective randomized crossover study was undertaken, involving basic life support mannequin-based simulation (BLS-MS) and a swine model of pulseless electrical activity (an unstable cardiac state) incorporating a fetal mannequin (PEA-FM). The BLS-MS (performed by certified rescuers) served to evaluate the quality of chest compressions in 30° left lateral tilt (LLT) and supine positions. Based on a 5-point scale, each rescuer subjectively graded their experience. The PEA-FM model was used to compare coronary perfusion pressure readings during CPR in supine, supine with left uterine displacement, 30° LLT, and 30° right lateral tilt positions. Compression rate and correctness of hand position, compression depth, and recoil were measures of compression quality (BLS-MS). Compared with LLT position, supine position enabled correct hand position (rate: 0.99 vs 0.88; p<0.05) and compression depth (rate: 0.76 vs 0.36; p<0.001) significantly more often. Moreover, BLS-MS rescuers found chest compressions significantly easier to perform with the mannequin in supine (vs LLT) position (difficulty score: 1.75 vs 3.95; p<0.001). In the PEA-FM study arm, supine position with left uterine displacement and right lateral tilt positions had the highest and lowest recorded coronary perfusion pressure readings, respectively. Supine position with left uterine displacement is optimal for maternal CPR. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Beskind, Daniel L; Stolz, Uwe; Thiede, Rebecca; Hoyer, Riley; Robertson, Whitney; Brown, Jeffrey; Ludgate, Melissa; Tiutan, Timothy; Shane, Romy; McMorrow, Deven; Pleasants, Michael; Kern, Karl B; Panchal, Ashish R
2017-09-01
CPR training at mass gathering events is an important part of health initiatives to improve cardiac arrest survival. However, it is unclear whether training lay bystanders using an ultra-brief video at a mass gathering event improves CPR quality and responsiveness. To determine if showing a chest-compression only (CCO) Ultra-Brief Video (UBV) at a mass gathering event is effective in teaching lay bystanders CCO-CPR. Prospective control trial in adults (age >18) who attended either a women's University of Arizona or a men's Phoenix Suns basketball game. Participants were evaluated using a standardized cardiac arrest scenario with Laerdal Skillreporter™ mannequins. CPR responsiveness (calling 911, time to calling 911, starting compressions within two minutes) and quality (compression rate, depth, hands-off time) were assessed for participants and data collected at Baseline and Post-intervention. Different participants were tested before and after the exposure of the UBV. Data were analyzed via the intention to treat principle using logistic regression for binary outcomes and median regression for continuous outcomes, controlling for clustering by venue. A total of 96 people were consented (Baseline=45; Post intervention=51). CPR responsiveness post intervention improved with faster time to calling 911 (s) and time to starting compressions (sec). Likewise, CPR quality improved with deeper compressions and improved hands-off time. Showing a UBV at a mass gathering sporting event is associated with improved CPR responsiveness and performance for lay bystanders. This data provides further support for the use of mass media interventions. Copyright © 2017 Elsevier B.V. All rights reserved.
Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T
2012-01-01
We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.
Edelson, Dana P.; Eilevstjønn, Joar; Weidman, Elizabeth K.; Retzer, Elizabeth; Vanden Hoek, Terry L.; Abella, Benjamin S.
2009-01-01
Objective Hyperventilation is both common and detrimental during cardiopulmonary resuscitation (CPR). Chest wall impedance algorithms have been developed to detect ventilations during CPR. However, impedance signals are challenged by noise artifact from multiple sources, including chest compressions. Capnography has been proposed as an alternate method to measure ventilations. We sought to assess and compare the adequacy of these two approaches. Methods Continuous chest wall impedance and capnography were recorded during consecutive in-hospital cardiac arrests. Algorithms utilizing each of these data sources were compared to a manually determined “gold standard” reference ventilation rate. In addition, a combination algorithm, which utilized the highest of the impedance or capnography values in any given minute, was similarly evaluated. Results Data were collected from 37 cardiac arrests, yielding 438 min of data with continuous chest compressions and concurrent recording of impedance and capnography. The manually calculated mean ventilation rate was 13.3±4.3/min. In comparison, the defibrillator’s impedance-based algorithm yielded an average rate of 11.3±4.4/min (p=0.0001) while the capnography rate was 11.7±3.7/min (p=0.0009). There was no significant difference in sensitivity and positive predictive value between the two methods. The combination algorithm rate was 12.4±3.5/min (p=0.02), which yielded the highest fraction of minutes with respiratory rates within 2/min of the reference. The impedance signal was uninterpretable 19.5% of the time, compared with 9.7% for capnography. However, the signals were only simultaneously non-interpretable 0.8% of the time. Conclusions Both the impedance and capnography-based algorithms underestimated the ventilation rate. Reliable ventilation rate determination may require a novel combination of multiple algorithms during resuscitation. PMID:20036047
[Basic life support in pediatrics].
Calvo Macías, A; Manrique Martínez, I; Rodríguez Núñez, A; López-Herce Cid, J
2006-09-01
Basic life support (BLS) is the combination of maneuvers that identifies the child in cardiopulmonary arrest and initiates the substitution of respiratory and circulatory function, without the use of technical adjuncts, until the child can receive more advanced treatment. BLS includes a sequence of steps or maneuvers that should be performed sequentially: ensuring the safety of rescuer and child, assessing unconsciousness, calling for help, positioning the victim, opening the airway, assessing breathing, ventilating, assessing signs of circulation and/or central arterial pulse, performing chest compressions, activating the emergency medical service system, and checking the results of resuscitation. The most important changes in the new guidelines are the compression: ventilation ratio and the algorithm for relieving foreign body airway obstruction. A compression/ ventilation ratio of 30:2 will be recommended for lay rescuers of infants, children and adults. Health professionals will use a compression: ventilation ratio of 15:2 for infants and children. If the health professional is alone, he/she may also use a ratio of 30:2 to avoid fatigue. In the algorithm for relieving foreign body airway obstruction, when the child becomes unconscious, the maneuvers will be similar to the BLS sequence with chest compressions (functioning as a deobstruction procedure) and ventilation, with reassessment of the mouth every 2 min to check for a foreign body, and evaluation of breathing and the presence of vital signs. BLS maneuvers are easy to learn and can be performed by anyone with adequate training. Therefore, BLS should be taught to all citizens.
Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L
2017-02-01
To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.
Mechanics of airway and alveolar collapse in human breath-hold diving.
Fitz-Clarke, John R
2007-11-15
A computational model of the human respiratory tract was developed to study airway and alveolar compression and re-expansion during deep breath-hold dives. The model incorporates the chest wall, supraglottic airway, trachea, branched airway tree, and elastic alveoli assigned time-dependent surfactant properties. Total lung collapse with degassing of all alveoli is predicted to occur around 235 m, much deeper than estimates for aquatic mammals. Hysteresis of the pressure-volume loop increases with maximum diving depth due to progressive alveolar collapse. Reopening of alveoli occurs stochastically as airway pressure overcomes adhesive and compressive forces on ascent. Surface area for gas exchange vanishes at collapse depth, implying that the risk of decompression sickness should reach a plateau beyond this depth. Pulmonary capillary transmural stresses cannot increase after local alveolar collapse. Consolidation of lung parenchyma might provide protection from capillary injury or leakage caused by vascular engorgement due to outward chest wall recoil at extreme depths.
Optimal control of CPR procedure using hemodynamic circulation model
Lenhart, Suzanne M.; Protopopescu, Vladimir A.; Jung, Eunok
2007-12-25
A method for determining a chest pressure profile for cardiopulmonary resuscitation (CPR) includes the steps of representing a hemodynamic circulation model based on a plurality of difference equations for a patient, applying an optimal control (OC) algorithm to the circulation model, and determining a chest pressure profile. The chest pressure profile defines a timing pattern of externally applied pressure to a chest of the patient to maximize blood flow through the patient. A CPR device includes a chest compressor, a controller communicably connected to the chest compressor, and a computer communicably connected to the controller. The computer determines the chest pressure profile by applying an OC algorithm to a hemodynamic circulation model based on the plurality of difference equations.
Hanna, Amgad; Bodden, Larry O'Neil; Siebiger, Gabriel R. L.
2018-01-01
Thoracic outlet syndrome (TOS) is caused by compression of the brachial plexus and/or subclavian vessels as they pass through the cervicothoracobrachial region, exiting the chest. There are three main types of TOS: neurogenic TOS, arterial TOS, and venous TOS. Neurogenic TOS accounts for approximately 95% of all cases, and it is usually caused by physical trauma (posttraumatic etiology), chronic repetitive motion (functional etiology), or bone or muscle anomalies (congenital etiology). We present two cases in which neurogenic TOS was elicited by vascular compression of the inferior portion of the brachial plexus. PMID:29497457
Gierczycka, Donata; Cronin, Duane S
2017-09-01
Recent epidemiological studies have identified that thoracic side airbags may vary in efficacy to reduce injury severity in side impact crash scenarios, while previous experimental and epidemiological studies have presented contrasting results. This study aimed to quantify the variations in occupant response in side impact conditions using a human body computational model integrated with a full vehicle model. The model was analyzed for a Moving Deformable Barrier side impact at 61km/h to assess two pre-crash arm positions, the incorporation of a seatbelt, and a thorax air bag on thorax response. The occupant response was evaluated using chest compression, the viscous criterion and thoracic spinal curvature. The arm position accounted for largest changes in the thorax response (106%) compared to the presence of the airbag and seatbelt systems (75%). It was also noted that the results were dependant on the method and location of thorax response measurement and this should be investigated further. Assessment using lateral displacement of the thoracic spine correlated positively with chest compression and Viscous Criterion, with the benefit of evaluating whole thorax response and provides a useful metric to compare occupant response for different side impact safety systems. The thoracic side airbag was found to increase the chest compression for the driving arm position (+70%), and reduced the injury metrics for the vertical arm position (-17%). This study demonstrated the importance of occupant arm position on variability in thoracic response, and provides insight for future design and optimization of side impact safety systems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Thielen, Mark; Joshi, Rohan; Delbressine, Frank; Bambang Oetomo, Sidarto; Feijs, Loe
2017-03-01
Cardiopulmonary resuscitation manikins are used for training personnel in performing cardiopulmonary resuscitation. State-of-the-art cardiopulmonary resuscitation manikins are still anatomically and physiologically low-fidelity designs. The aim of this research was to design a manikin that offers high anatomical and physiological fidelity and has a cardiac and respiratory system along with integrated flow sensors to monitor cardiac output and air displacement in response to cardiopulmonary resuscitation. This manikin was designed in accordance with anatomical dimensions using a polyoxymethylene rib cage connected to a vertebral column from an anatomical female model. The respiratory system was composed of silicon-coated memory foam mimicking lungs, a polyvinylchloride bronchus and a latex trachea. The cardiovascular system was composed of two sets of latex tubing representing the pulmonary and aortic arteries which were connected to latex balloons mimicking the ventricles and lumped abdominal volumes, respectively. These balloons were filled with Life/form simulation blood and placed inside polyether foam. The respiratory and cardiovascular systems were equipped with flow sensors to gather data in response to chest compressions. Three non-medical professionals performed chest compressions on this manikin yielding data corresponding to force-displacement while the flow sensors provided feedback. The force-displacement tests on this manikin show a desirable nonlinear behaviour mimicking chest compressions during cardiopulmonary resuscitation in humans. In addition, the flow sensors provide valuable data on the internal effects of cardiopulmonary resuscitation. In conclusion, scientifically designed and anatomically high-fidelity designs of cardiopulmonary resuscitation manikins that embed flow sensors can improve physiological fidelity and provide useful feedback data.
Karim, Habib Md. Reazaul; Yunus, Md.; Bhattacharyya, Prithwis; Ahmed, Ghazal
2016-01-01
Background: Basic life support (BLS) is an integral part of emergency medical care. Studies have shown poor knowledge of it among health care providers who are usually taught BLS by lecture-based teachings in classes. Objectives: This study is designed to assess the effectiveness of class lecture versus workshop-based teaching of BLS on acquiring the practice skills on mannequin. Methods: After ethical approval and informed consent from the participants, the present study was conducted among the health care providers. Participants were grouped in lecture-based class teaching and workshop-based teaching. They were then asked to practice BLS on mannequin (Resusci Anne with QCPR) and evaluated as per performance parameters based on American Heart Association BLS. Statistical analyses are done by Fisher's exact t-test using GraphPad INSTAT software and P < 0.05 is taken as significant. Results: There were 55 participants in lecture-based teaching and 50 in workshop-based teaching group. There is no statistical difference in recognition of arrest, checking pulse, and starting chest compression (P > 0.05). Though more than 83% of lecture-based teaching group has started chest compression as compared 96% of workshop group; only 49% of the participants of lecture-based group performed quality chest compression as compared to 82% of other group (P = 0.0005). The workshop group also performed better bag mask ventilation and defibrillation (P < 0.0001). Conclusion: Workshop-based BLS teaching is more effective and lecture-based class teaching better is replaced in medical education curriculum. PMID:27308252
Asai, Hideki; Fukushima, Hidetada; Bolstad, Francesco; Okuchi, Kazuo
2018-04-01
Bystander cardiopulmonary resuscitation (CPR) is essential for improving the outcomes of sudden cardiac arrest patients. It has been reported that dispatch-assisted CPR (DACPR) accounts for more than half of the incidence of CPR undertaken by bystanders. Its quality, however, can be suboptimal. We aimed to measure the quality of DACPR using a simulation study. We recruited laypersons at a shopping mall and measured the quality of CPR carried out in our simulation. Dispatchers provided instruction in accordance with the standard DACPR protocol in Japan. Twenty-three laypersons (13 with CPR training experience within the past 2 years and 10 with no training experience) participated in this study. The median chest compression rate and depth were 106/min and 33 mm, respectively. The median time interval from placing the 119 call to the start of chest compressions was 119 s. No significant difference was found between the groups with and without training experience. However, subjects with training experience more frequently placed their hands correctly on the manikin (84.6% versus 40.0%; P = 0.026). Twelve participants (52.2%, seven in trained and five in untrained group) interrupted chest compressions for 3-18 s, because dispatchers asked if the patient started breathing or moving. This current simulation study showed that the quality of DACPR carried out by lay rescuers can be less than optimal in terms of depth, hand placement, and minimization of pauses. Further studies are required to explore better DACPR instruction methods to help lay rescuers perform CPR with optimal quality.
Karim, Habib Md Reazaul; Yunus, Md; Bhattacharyya, Prithwis; Ahmed, Ghazal
2016-01-01
Basic life support (BLS) is an integral part of emergency medical care. Studies have shown poor knowledge of it among health care providers who are usually taught BLS by lecture-based teachings in classes. This study is designed to assess the effectiveness of class lecture versus workshop-based teaching of BLS on acquiring the practice skills on mannequin. After ethical approval and informed consent from the participants, the present study was conducted among the health care providers. Participants were grouped in lecture-based class teaching and workshop-based teaching. They were then asked to practice BLS on mannequin (Resusci Anne with QCPR) and evaluated as per performance parameters based on American Heart Association BLS. Statistical analyses are done by Fisher's exact t-test using GraphPad INSTAT software and P < 0.05 is taken as significant. There were 55 participants in lecture-based teaching and 50 in workshop-based teaching group. There is no statistical difference in recognition of arrest, checking pulse, and starting chest compression (P > 0.05). Though more than 83% of lecture-based teaching group has started chest compression as compared 96% of workshop group; only 49% of the participants of lecture-based group performed quality chest compression as compared to 82% of other group (P = 0.0005). The workshop group also performed better bag mask ventilation and defibrillation (P < 0.0001). Workshop-based BLS teaching is more effective and lecture-based class teaching better is replaced in medical education curriculum.
Meert, Kathleen L; Telford, Russell; Holubkov, Richard; Slomine, Beth S; Christensen, James R; Dean, J Michael; Moler, Frank W
2016-12-01
To investigate relationships between cardiac arrest characteristics and survival and neurobehavioral outcome among children recruited to the Therapeutic Hypothermia after Pediatric Cardiac Arrest Out-of-Hospital trial. Secondary analysis of Therapeutic Hypothermia after Pediatric Cardiac Arrest Out-of-Hospital trial data. Thirty-six PICUs in the United States and Canada. All children (n = 295) had chest compressions for greater than or equal to 2 minutes, were comatose, and required mechanical ventilation after return of circulation. Neurobehavioral function was assessed using the Vineland Adaptive Behavior Scales, Second Edition at baseline (reflecting prearrest status) and 12 months postarrest. U.S. norms for Vineland Adaptive Behavior Scales, Second Edition scores are 100 (mean) ± 15 (SD). Higher scores indicate better functioning. Outcomes included 12-month survival and 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70. Cardiac etiology of arrest, initial arrest rhythm of ventricular fibrillation/tachycardia, shorter duration of chest compressions, compressions not required at hospital arrival, fewer epinephrine doses, and witnessed arrest were associated with greater 12-month survival and 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70. Weekend arrest was associated with lower 12-month survival. Body habitus was associated with 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70; underweight children had better outcomes, and obese children had worse outcomes. On multivariate analysis, acute life threatening event/sudden unexpected infant death, chest compressions more than 30 minutes, and weekend arrest were associated with lower 12-month survival; witnessed arrest was associated with greater 12-month survival. Acute life threatening event/sudden unexpected infant death, other respiratory causes of arrest except drowning, other/unknown causes of arrest, and compressions more than 30 minutes were associated with lower 12-month survival with Vineland Adaptive Behavior Scales, Second Edition greater than or equal to 70. Many factors are associated with survival and neurobehavioral outcome among children who are comatose and require mechanical ventilation after out-of-hospital cardiac arrest. These factors may be useful for identifying children at risk for poor outcomes, and for improving prevention and resuscitation strategies.
Khalpey, Zain; Kazui, Toshinobu; Ferng, Alice S; Connell, Alana; Tran, Phat L; Meyer, Mark; Rawashdeh, Badi; Smith, Richard G; Sweitzer, Nancy K; Friedman, Mark; Lick, Scott; Slepian, Marvin J; Copeland, Jack G
2016-01-01
The 70 cc total artificial heart (TAH) has been utilized as bridge to transplant (BTT) for biventricular failure. However, the utilization of 70 cc TAH has been limited to large patients for the low output from the pulmonary as well as systemic vein compression after chest closure. Therefore, the 50 cc TAH was developed by SynCardia (Tucson, AZ) to accommodate smaller chest cavity. We report the first TAH exchange from a 70 to 50 cc due to a fit difficulty. The patient failed to be closed with a 70 cc TAH, although the patient met the conventional 70 cc TAH fit criteria. We successfully closed the chest with a 50 cc TAH.
Eccentric mastectomy and zigzag periareolar incision for gynecomastia.
Tu, Lung-Chen; Tung, Kwang-Yi; Chen, Heng-Chang; Huang, Wen-Chen; Hsiao, Hung-Tao
2009-07-01
Gynecomastia is enlargement of the male breast caused by gland proliferation. Surgery is performed for symptom relief or for cosmetic reasons. The authors used a modified operative procedure, then evaluated the results and safety. Between 2001 and 2005, 22 men (median age, 26 years; range, 13-63 years) with gynecomastia underwent surgery. The operative procedure included a zigzag periareolar skin incision, eccentric subcutaneous mastectomy, and liposuction, with postoperative compression. All the patients were satisfied with the results of the surgery, which produced a chest contour resembling a normal male chest rather than simply a smaller breast. The only complication was a hematoma. One patient was found to have breast cancer. The normal male chest contour can be restored by the described method of eccentric subcutaneous mastectomy.
Memory hierarchy using row-based compression
Loh, Gabriel H.; O'Connor, James M.
2016-10-25
A system includes a first memory and a device coupleable to the first memory. The device includes a second memory to cache data from the first memory. The second memory includes a plurality of rows, each row including a corresponding set of compressed data blocks of non-uniform sizes and a corresponding set of tag blocks. Each tag block represents a corresponding compressed data block of the row. The device further includes decompression logic to decompress data blocks accessed from the second memory. The device further includes compression logic to compress data blocks to be stored in the second memory.
Yang, Zhengfei; Liu, Qingyu; Zheng, Guanghui; Liu, Zhifeng; Jiang, Longyuan; Lin, Qing; Chen, Rui; Tang, Wanchun
2017-09-01
A compression-ventilation (C:V) ratio of 30:2 is recommended for adult cardiopulmonary resuscitation (CPR) by the current American Heart Association (AHA) guidelines. However, continuous chest compression (CCC) is an alternative strategy for CPR that minimizes interruption especially when an advanced airway exists. In this study, we investigated the effects of 30:2 mechanical CPR when compared with CCC in combination with regular ventilation in a porcine model. Sixteen male domestic pigs weighing 39±2 kg were utilized. Ventricular fibrillation was induced and untreated for 7 min. The animals were then randomly assigned to receive CCC combined with regular ventilation (CCC group) or 30:2 CPR (VC group). Mechanical chest compression was implemented with a miniaturized mechanical chest compressor. At the same time of beginning of precordial compression, the animals were mechanically ventilated at a rate of 10 breaths-per-minute in the CCC group or with a 30:2 C:V ratio in the VC group. Defibrillation was delivered by a single 150 J shock after 5 min of CPR. If failed to resuscitation, CPR was resumed for 2 min before the next shock. The protocol was stopped if successful resuscitation or at a total of 15 min. The resuscitated animals were observed for 72 h. Coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow in the VC group were similar to those achieved in the CCC group during CPR. No significant differences were observed in arterial blood gas parameters between two groups at baseline, VF 6 min, CPR 4 min and 30, 120 and 360 min post-resuscitation. Although extravascular lung water index of both groups significantly increased after resuscitation, no distinct difference was found between CCC and VC groups. All animals were successfully resuscitated and survived for 72 h with favorable neurologic outcomes in both groups. However, obviously more numbers of rib fracture were observed in CCC animals in comparison with VC animals. There was no difference in hemodynamic efficacy and gas exchange during and after resuscitation, therefore identical 72 h survival with intact neurologic function was observed in both VC and CCC groups. However, the incidence of rib fracture increases during the mechanical CPR strategy of CCC combined with regular ventilations.
Lee, Donghee; Erickson, Alek; You, Taesun; Dudley, Andrew T; Ryu, Sangjin
2018-06-13
Hyaline cartilage is a specialized type of connective tissue that lines many moveable joints (articular cartilage) and contributes to bone growth (growth plate cartilage). Hyaline cartilage is composed of a single cell type, the chondrocyte, which produces a unique hydrated matrix to resist compressive stress. Although compressive stress has profound effects on transcriptional networks and matrix biosynthesis in chondrocytes, mechanistic relationships between strain, signal transduction, cell metabolism, and matrix production remain superficial. Here, we describe development and validation of a polydimethylsiloxane (PDMS)-based pneumatic microfluidic cell compression device which generates multiple compression conditions in a single platform. The device contained an array of PDMS balloons of different sizes which were actuated by pressurized air, and the balloons compressed chondrocytes cells in alginate hydrogel constructs. Our characterization and testing of the device showed that the developed platform could compress chondrocytes with various magnitudes simultaneously with negligible effect on cell viability. Also, the device is compatible with live cell imaging to probe early effects of compressive stress, and it can be rapidly dismantled to facilitate molecular studies of compressive stress on transcriptional networks. Therefore, the proposed device will enhance the productivity of chondrocyte mechanobiology studies, and it can be applied to study mechanobiology of other cell types.
Convolution neural-network-based detection of lung structures
NASA Astrophysics Data System (ADS)
Hasegawa, Akira; Lo, Shih-Chung B.; Freedman, Matthew T.; Mun, Seong K.
1994-05-01
Chest radiography is one of the most primary and widely used techniques in diagnostic imaging. Nowadays with the advent of digital radiology, the digital medical image processing techniques for digital chest radiographs have attracted considerable attention, and several studies on the computer-aided diagnosis (CADx) as well as on the conventional image processing techniques for chest radiographs have been reported. In the automatic diagnostic process for chest radiographs, it is important to outline the areas of the lungs, the heart, and the diaphragm. This is because the original chest radiograph is composed of important anatomic structures and, without knowing exact positions of the organs, the automatic diagnosis may result in unexpected detections. The automatic extraction of an anatomical structure from digital chest radiographs can be a useful tool for (1) the evaluation of heart size, (2) automatic detection of interstitial lung diseases, (3) automatic detection of lung nodules, and (4) data compression, etc. Based on the clearly defined boundaries of heart area, rib spaces, rib positions, and rib cage extracted, one should be able to use this information to facilitate the tasks of the CADx on chest radiographs. In this paper, we present an automatic scheme for the detection of lung field from chest radiographs by using a shift-invariant convolution neural network. A novel algorithm for smoothing boundaries of lungs is also presented.
Electrophysiology of Muscle Fatigue in Cardiopulmonary Resuscitation on Manikin Model.
Cobo-Vázquez, Carlos; De Blas, Gemma; García-Canas, Pablo; Del Carmen Gasco-García, María
2018-01-01
Cardiopulmonary resuscitation requires the provider to adopt positions that could be dangerous for his or her spine, specifically affecting the muscles and ligaments in the lumbar zone and the scapular spinal muscles. Increased fatigue caused by muscular activity during the resuscitation could produce a loss of quality and efficacy, resulting in compromising resuscitation. The aim of this study was to evaluate the maximum time a rescuer can perform uninterrupted chest compressions correctly without muscle fatigue. This pilot study was performed at Universidad Complutense de Madrid (Spain) with the population recruited following CONSORT 2010 guidelines. From the 25 volunteers, a total of 14 students were excluded because of kyphoscoliosis (4), lumbar muscle pain (1), anti-inflammatory treatment (3), or not reaching 80% of effective chest compressions during the test (6). Muscle activity at the high spinal and lumbar (L5) muscles was assessed using electromyography while students performed continuous chest compressions on a ResusciAnne manikin. The data from force exerted were analyzed according to side and muscle groups using Student's t test for paired samples. The influence of time, muscle group, and side was analyzed by multivariate analyses ( p ≤ .05). At 2 minutes, high spinal muscle activity (right: 50.82 ± 9.95; left: 57.27 ± 20.85 μV/ms) reached the highest values. Activity decreased at 5 and 15 minutes. At 2 minutes, L5 activity (right: 45.82 ± 9.09; left: 48.91 ± 10.02 μV/ms) reached the highest values. After 5 minutes and at 15 minutes, activity decreased. Fatigue occurred bilaterally and time was the most important factor. Fatigue began at 2 minutes. Rescuers exert muscular countervailing forces in order to maintain effective compressions. This imbalance of forces could determine the onset of poor posture, musculoskeletal pain, and long-term injuries in the rescuer.
Schmölzer, Georg M; O Reilly, Megan; Fray, Caroline; van Os, Sylvia; Cheung, Po-Yin
2017-10-07
Current neonatal resuscitation guidelines recommend 3:1 compression:ventilation (C:V) ratio. Recently, animal studies reported that continuous chest compressions (CC) during a sustained inflation (SI) significantly improved return of spontaneous circulation (ROSC). The approach of CC during SI (CC+SI) has not been examined in the delivery room during neonatal resuscitation. It is a feasibility study to compare CC+SI versus 3:1 C:V ratio during neonatal resuscitation in the delivery room. We hypothesised that during neonatal resuscitation, CC+SI will reduce the time to ROSC. Our aim was to examine if CC+SI reduces ROSC compared with 3:1 C:V CPR in preterm infants <33 weeks of gestation. Randomised feasibility trial. Once CC was indicated all eligible infants were immediately and randomly allocated to either CC+SI group or 3:1 C:V group. A sequentially numbered, brown, sealed envelope contained a folded card box with the treatment allocation was opened by the clinical team at the start of CC. Infants in the CC+SI group received CC at a rate of 90/min during an SI with a duration of 20 s (CC+SI). After 20 s, the SI was interrupted for 1 s and the next SI was started for another 20 s until ROSC. Infants in the '3:1 group' received CC using 3:1 C:V ratio until ROSC. Overall the mean (SD) time to ROSC was significantly shorter in the CC+SI group with 31 (9) s compared with 138 (72) s in the 3:1 C:V group (p=0.011). CC+SI is feasible in the delivery room. Clinicaltrials.gov NCT02083705, pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Moore, C S; Wood, T J; Avery, G; Balcam, S; Needler, L; Beavis, A W; Saunderson, J R
2014-05-07
The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.
NASA Astrophysics Data System (ADS)
Moore, C. S.; Wood, T. J.; Avery, G.; Balcam, S.; Needler, L.; Beavis, A. W.; Saunderson, J. R.
2014-05-01
The purpose of this study was to examine the use of three physical image quality metrics in the calibration of an automatic exposure control (AEC) device for chest radiography with a computed radiography (CR) imaging system. The metrics assessed were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and mean effective noise equivalent quanta (eNEQm), all measured using a uniform chest phantom. Subsequent calibration curves were derived to ensure each metric was held constant across the tube voltage range. Each curve was assessed for its clinical appropriateness by generating computer simulated chest images with correct detector air kermas for each tube voltage, and grading these against reference images which were reconstructed at detector air kermas correct for the constant detector dose indicator (DDI) curve currently programmed into the AEC device. All simulated chest images contained clinically realistic projected anatomy and anatomical noise and were scored by experienced image evaluators. Constant DDI and CNR curves do not appear to provide optimized performance across the diagnostic energy range. Conversely, constant eNEQm and SNR do appear to provide optimized performance, with the latter being the preferred calibration metric given as it is easier to measure in practice. Medical physicists may use the SNR image quality metric described here when setting up and optimizing AEC devices for chest radiography CR systems with a degree of confidence that resulting clinical image quality will be adequate for the required clinical task. However, this must be done with close cooperation of expert image evaluators, to ensure appropriate levels of detector air kerma.
Winkler, Bernd E; Muellenbach, Ralf M; Wurmb, Thomas; Struck, Manuel F; Roewer, Norbert; Kranke, Peter
2017-02-01
While controlled ventilation is most frequently used during cardiopulmonary resuscitation (CPR), the application of continuous positive airway pressure (CPAP) and passive ventilation of the lung synchronously with chest compressions and decompressions might represent a promising alternative approach. One benefit of CPAP during CPR is the reduction of peak airway pressures and therefore a potential enhancement in haemodynamics. We therefore evaluated the tidal volumes and airway pressures achieved during CPAP-CPR. During CPR with the LUCAS™ 2 compression device, a manikin model was passively ventilated at CPAP levels of 5, 10, 20 and 30 hPa with the Boussignac tracheal tube and the ventilators Evita ® V500, Medumat ® Transport, Oxylator ® EMX, Oxylog ® 2000, Oxylog ® 3000, Primus ® and Servo ® -i as well as the Wenoll ® diver rescue system. Tidal volumes and airway pressures during CPAP-CPR were recorded and analyzed. Tidal volumes during CPAP-CPR were higher than during compression-only CPR without positive airway pressure. The passively generated tidal volumes increased with increasing CPAP levels and were significantly influenced by the ventilators used. During ventilation at 20 hPa CPAP via a tracheal tube, the mean tidal volumes ranged from 125 ml (Medumat ® ) to 309 ml (Wenoll ® ) and the peak airway pressures from 23 hPa (Primus ® ) to 49 hPa (Oxylog ® 3000). Transport ventilators generated lower tidal volumes than intensive care ventilators or closed-circuit systems. Peak airway pressures during CPAP-CPR were lower than those during controlled ventilation CPR reported in literature. High peak airway pressures are known to limit the applicability of ventilation via facemask or via supraglottic airway devices and may adversely affect haemodynamics. Hence, the application of ventilators generating high tidal volumes with low peak airway pressures appears desirable during CPAP-CPR. The limited CPAP-CPR capabilities of transport ventilators in our study might be prerequisite for future developments of transport ventilators.
Traumatic asphyxia due to blunt chest trauma: a case report and literature review
2012-01-01
Introduction Crush asphyxia is different from positional asphyxia, as respiratory compromise in the latter is caused by splinting of the chest and/or diaphragm, thus preventing normal chest expansion. There are only a few cases or small case series of crush asphyxia in the literature, reporting usually poor outcomes. Case presentation We present the case of a 44-year-old Caucasian man who developed traumatic asphyxia with severe thoracic injury and mild brain edema after being crushed under heavy auto vehicle mechanical parts. He remained unconscious for an unknown time. The treatment included oropharyngeal intubation and mechanical ventilation, bilateral chest tube thoracostomies, treatment of brain edema and other supportive measures. Our patient’s outcome was good. Traumatic asphyxia is generally under-reported and most authors apply supportive measures, while the final outcome seems to be dependent on the length of time of the chest compression and on the associated injuries. Conclusion Treatment for traumatic asphyxia is mainly supportive with special attention to the re-establishment of adequate oxygenation and perfusion; treatment of the concomitant injuries might also affect the final outcome. PMID:22935547
Hendrix, W C; Arruda, L K; Platts-Mills, T A; Haworth, C S; Jabour, R; Ward, G W
1992-06-01
A 57-yr-old man with a chronic lung cavity presumed to be related to ankylosing spondylitis and/or old cavitary tuberculosis presented with hemoptysis and rapidly developed lower extremity paresis and hypoesthesia. On chest radiograph he had a left upper lobe lesion suggestive of aspergilloma combined with a large left empyema with bronchopleural fistula. Serologic analysis demonstrated precipitins and very high titer IgG antibodies to Aspergillus fumigatus antigens. Decompressive laminectomy from T1 to T5 was performed, with drainage of A. fumigatus culture-positive material from an epidural abscess compressing the spinal cord. Chest drainage was required for control of the empyema. With a total course of 3 g of intravenously administered amphotericin B, rehabilitative therapy, and chronic empyema drainage, he is now at home and ambulatory with assistance. He is also being followed by regular serum assays of IgG antibodies to Aspergillus proteins. We report the case of an apparent long-term survivor of a formerly lethal and/or nonreversible paraplegic condition. The critical factors compared with previous cases with a poor outcome would appear to be prompt neurosurgical intervention, restoration of a normal number of T-cells, effective long-term chest drainage, and high dose amphotericin treatment.
A traumatic asphyxia in a child.
Nishiyama, T; Hanaoka, K
2000-11-01
Traumatic asphyxia in a child is rare and the pathophysiology is different from that occurring in an adult. We report a case of traumatic asphyxia in a child who recovered without specific treatment, even though chest and abdominal compression was severe. A three-year-old boy (14.2 kg) was run over by the rear wheel of a Jeep. He was under the tire for about three minutes and then was transferred to our hospital. When he arrived, he was lethargic with Glasgow Coma Scale of E3V4M6 (coma score of 13). He was cyanotic in his face and had a tire mark from the left shoulder to the right abdomen, petechiae on the head, face, conjunctiva and chest, oral bleeding, and facial edema. Serum concentrations of liver enzymes were increased and microhematuria was detected. However, no injuries were seen in the brain, eye, chest, or abdomen. Cyanosis disappeared in a few hours. Facial and thoracic petechiae disappeared in three days and that of the conjunctiva in five days. He was discharged from hospital on the 13th day without any disturbances. We present a three-year-old boy with traumatic asphyxia. He had no complications although he received severe thoraco-abdominal compression by a Jeep.
Beard, Matthew; Swain, Andrew; Dunning, Andrew; Baine, Julie; Burrowes, Corey
2015-05-01
Survival from out-of-hospital cardiac arrest is increased by bystander cardiopulmonary resuscitation (CPR). Bystander performance can be improved when CPR instructions are delivered by a calltaker at the Emergency Communications Centre. Little is known about a young person's ability to understand these instructions and perform CPR correctly. We assessed the ability of a group of untrained young people to effectively apply these directions to an adult resuscitation manikin. 87 youngsters aged 7-15 years with no previous training in CPR were separately equipped with a mobile phone and an adult assessment manikin. They phoned the emergency number (111) and were automatically diverted to a senior emergency medical dispatcher (EMD). The EMD delivered resuscitation instructions which complied fully with Medical Priority Dispatch System (version 12.1). Performance was monitored using a Laerdal Computerised Skill Reporting System. Average compression depth increased with age from 10.3 mm to 30 mm for 8 and 15 year olds respectively. 100 compressions per minute was achieved in youngsters aged 10 years and older but the rate fatigued over time and improved after interruption for two ventilations. Those aged 11 years and older consistently compressed the chest from 31 mm to 50mm. Only one participant could successfully ventilate the manikin by mouth-to-mouth. This study demonstrates that untrained youngsters should perform compression-only CPR. From 11 years of age, they can effectively perform dispatcher-directed CPR by compressing the chest at an appropriate rate and depth. However, their technique benefits from formal training. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Contri, Enrico; Burkart, Roman; Borrelli, Paola; Ferraro, Ottavia Eleonora; Tonani, Michela; Cutuli, Amedeo; Bertaia, Daniele; Iozzo, Pasquale; Tinguely, Caroline; Lopez, Daniel; Boldarin, Susi; Deiuri, Claudio; Dénéréaz, Sandrine; Dénéréaz, Yves; Terrapon, Michael; Tami, Christian; Cereda, Cinzia; Somaschini, Alberto; Cornara, Stefano; Cortegiani, Andrea
2018-01-01
Introduction Out-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR. Methods and analysis This is a prospective randomised trial performed in eight training centres. Laypeople who passed a basic life support course will be randomised to one of the four CPR protocols in an 8 min simulated cardiac arrest scenario on a manikin: (1) 30 compressions and 2 s pause; (2) 50 compressions and 5 s pause; (3) 100 compressions and 10 s pause; (4) hands-only. The calculated sample size is 552 people. The primary outcome is the percentage of chest compression performed with correct depth evaluated by a computerised feedback system (Laerdal QCPR). Ethics and dissemination Due to the nature of the study, we obtained a waiver from the Ethics Committee (IRCCS Policlinico San Matteo, Pavia, Italy). All participants will sign an informed consent form before randomisation. The results of this study will be published in peer-reviewed journal. The data collected will also be made available in a public data repository. Trial registration number NCT02632500. PMID:29674365
Compression for the management of venous leg ulcers: which material do we have?
Partsch, Hugo
2014-05-01
Compression therapy is the most important basic treatment modality in venous leg ulcers. The review focusses on the materials which are used: 1. Compression bandages, 2. Compression stockings, 3. Self-adjustable Velcro-devices, 4. Compression pumps, 5. Hybrid devices. Compression bandages, usually applied by trained staff, provide a wide spectrum of materials with different elastic properties. To make bandaging easier, safer and more effective, most modern bandages combine different material components. Self-management of venous ulcers has become feasible by introducing double compression stockings ("ulcer kits") and self-adjustable Velcro devices. Compression pumps can be used as adjunctive measures, especially for patients with restricted mobility. The combination of sustained and intermittent compression ("hybrid device") is a promising new tool. The interface pressure corresponding to the dosage of compression therapy determines the hemodynamic efficacy of each device. In order to reduce ambulatory venous hypertension compression pressures of more than 50 mm Hg in the upright position are desirable. At the same time pressure should be lower in the resting position in order to be tolerated. This prerequisite may be fulfilled by using inelastic, short stretch material including multicomponent bandages and cohesive surfaces, all characterized by high stiffness. Such materials do not give way when calf muscles contract during walking which leads to high peaks of interface pressure ("massaging effect"). © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Frank, Matthias; Bockholdt, Britta; Peters, Dieter; Lange, Joern; Grossjohann, Rico; Ekkernkamp, Axel; Hinz, Peter
2011-05-20
Blunt ballistic impact trauma is a current research topic due to the widespread use of kinetic energy munitions in law enforcement. In the civilian setting, an automatic dummy launcher has recently been identified as source of blunt impact trauma. However, there is no data on the injury risk of conventional dummy launchers. It is the aim of this investigation to predict potential impact injury to the human head and chest on the basis of the Blunt Criterion which is an energy based blunt trauma model to assess vulnerability to blunt weapons, projectile impacts, and behind-armor-exposures. Based on experimentally investigated kinetic parameters, the injury risk of two commercially available gundog retrieval devices (Waidwerk Telebock, Germany; Turner Richards, United Kingdom) was assessed using the Blunt Criterion trauma model for blunt ballistic impact trauma to the head and chest. Assessing chest impact, the Blunt Criterion values for both shooting devices were higher than the critical Blunt Criterion value of 0.37, which represents a 50% risk of sustaining a thoracic skeletal injury of AIS 2 (moderate injury) or AIS 3 (serious injury). The maximum Blunt Criterion value (1.106) was higher than the Blunt Criterion value corresponding to AIS 4 (severe injury). With regard to the impact injury risk to the head, both devices surpass by far the critical Blunt Criterion value of 1.61, which represents a 50% risk of skull fracture. Highest Blunt Criterion values were measured for the Turner Richards Launcher (2.884) corresponding to a risk of skull fracture of higher than 80%. Even though the classification as non-guns by legal authorities might implicate harmlessness, the Blunt Criterion trauma model illustrates the hazardous potential of these shooting devices. The Blunt Criterion trauma model links the laboratory findings to the impact injury patterns of the head and chest that might be expected. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Watts, Sarah; Smith, Jason; Gwyther, Robert; Kirkman, Emrys
2017-12-01
Closed chest compressions (CCC) are a key component of resuscitation from medical causes of cardiac arrest, but when haemorrhage, the leading cause of preventable battlefield deaths, is the likely cause there is little evidence to support their use. Resuscitation protocols for traumatic cardiac arrest (TCA) highlight the importance of addressing reversible causes, such as the administration of fluids to treat hypovolaemia. This study evaluated whether CCC were beneficial following haemorrhage-induced TCA and additionally whether resuscitation with blood improved physiological outcomes. The study was conducted with the authority of UK Animals (Scientific Procedures) Act 1986 using 39 terminally anesthetised Large White pigs (35 kg, 29-40 kg) instrumented for invasive physiological monitoring. Following instrumentation and baseline measurements, animals underwent tissue injury (captive bolt to the right thigh) and controlled haemorrhage (30% blood volume). Mean arterial blood pressure (MAP) was maintained at 45 mmHg for 60 min, followed by a further controlled haemorrhage to a MAP of 20 mmHg. As arterial blood and pulse pressures spontaneously deteriorated further over a 5 min period, the randomised resuscitation protocol was initiated as follows: CCC (n=6); IV 0.9% saline (Sal n=8); IV autologous whole blood (WB n=8); IV saline +chest compressions (Sal +CCC n=9); and IV whole blood +chest compressions (WB +CCC n=8). 3×10 ml/kg fluid boluses were administered using the Belmont Rapid Infuser (200 ml/min). CCC were performed using the LUCAS II Chest Compression System.Outcome was attainment of return of spontaneous circulation (ROSC) 15 min post-resuscitation. ROSC was categorised by MAP (MAP ≥50 mmHg=ROSC; MAP >20 <50 mmHg=partial ROSC; MAP ≤20 mmHg=dead).emermed;34/12/A866-a/F1F1F1Figure 1 RESULTS: Outcome was significantly worse in the group that received CCC compared to WB and Sal groups (6/6 dead versus 0/8 and 0/8 respectively) (p<0.0001).A significantly higher number of animals attained ROSC in WB compared to Sal group (6/8 versus 0/8 ROSC and 2/8 versus 8/8 partial ROSC respectively) (p=0.0069).There were some none significant differences between WB and WB+CCC groups (6/8 versus 5/8 ROSC, 2/8 versus 1/8 partial ROSC and 0/8 versus 2/8 dead respectively) (p=0.4411).No animals attained ROSC in the Sal and Sal+CCC groups however significantly more animals died in the Sal+CCC group (0/8 versus 0/9 ROSC, 8/8 versus 2/9 partial ROSC and 0/8 versus 7/9 dead respectively) (p=0.0023). CCC were associated with increased mortality compared to intravenous fluid resuscitation. Resuscitation with whole blood demonstrated the greatest physiological benefit as demonstrated by highest numbers of animals achieving ROSC. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Güler, N; Bilge, M; Eryonucu, B; Cirak, B
2000-10-01
We report two cases of acute cervical angina and ECG changes induced by anteflexion of the head. Cervical angina is defined as chest pain that resembles true cardiac angina but originates from cervical discopathy with nerve root compression. In these patients, Prinzmetal's angina, valvular heart disease, congenital heart disease, left ventricular aneurysm, and cardiomyopathy were excluded. After all, the patient's chest pain was reproduced by anteflexion of head, at this time, their ECGs showed nonspecific ST-T changes in the inferior and anterior leads different from the basal ECG. ECG changes returned to normal when the patient's neck moved to the neutral position. To our knowledge, these are the first cases of cervical angina associated with acute ECG changes by neck motion.
Image splitting and remapping method for radiological image compression
NASA Astrophysics Data System (ADS)
Lo, Shih-Chung B.; Shen, Ellen L.; Mun, Seong K.
1990-07-01
A new decomposition method using image splitting and gray-level remapping has been proposed for image compression, particularly for images with high contrast resolution. The effects of this method are especially evident in our radiological image compression study. In our experiments, we tested the impact of this decomposition method on image compression by employing it with two coding techniques on a set of clinically used CT images and several laser film digitized chest radiographs. One of the compression techniques used was full-frame bit-allocation in the discrete cosine transform domain, which has been proven to be an effective technique for radiological image compression. The other compression technique used was vector quantization with pruned tree-structured encoding, which through recent research has also been found to produce a low mean-square-error and a high compression ratio. The parameters we used in this study were mean-square-error and the bit rate required for the compressed file. In addition to these parameters, the difference between the original and reconstructed images will be presented so that the specific artifacts generated by both techniques can be discerned by visual perception.
NASA Astrophysics Data System (ADS)
Tornai, Martin P.; McKinley, Randolph L.; Bryzmialkiewicz, Caryl N.; Cutler, Spencer J.; Crotty, Dominic J.
2005-04-01
With the development of several classes of dedicated emission and transmission imaging technologies utilizing ionizing radiation for improved breast cancer detection and in vivo characterization, it is extremely useful to have available anthropomorphic breast phantoms in a variety of shapes, sizes and malleability prior to clinical imaging. These anthropomorphic phantoms can be used to evaluate the implemented imaging approaches given a known quantity, the phantom, and to evaluate the variability of the measurement due to the imaging system chain. Thus, we have developed a set of fillable and incompressible breast phantoms ranging in volume from 240 to 1730mL with nipple-to-chest distances from 3.8 to 12cm. These phantoms are mountable and exchangeable on either a uniform chest plate or anthropomorphic torso phantom containing tissue equivalent bones and surface tissue. Another fillable ~700mL breast phantom with solid anterior chest plate is intentionally compressible, and can be used for direct comparisons between standard planar imaging approaches using mild-to-severe compression, partially compressed tomosynthesis, and uncompressed computed mammotomography applications. These phantoms can be filled with various fluids (water and oil based liquids) to vary the fatty tissue background composition. Shaped cellulose sponges with two cell densities are fabricated and can be added to the breasts to simulate connective tissue. Additionally, microcalcifications can be simulated by peppering slits in the sponges with oyster shell fragments. These phantoms have a utility in helping to evaluate clinical imaging paradigms with known input object parameters using basic imaging characterization, in an effort to further evaluate contemporary and next generation imaging tools. They may additionally provide a means to collect known data samples for task based optimization studies.
Ultrasound use during cardiopulmonary resuscitation is associated with delays in chest compressions.
Huis In 't Veld, Maite A; Allison, Michael G; Bostick, David S; Fisher, Kiondra R; Goloubeva, Olga G; Witting, Michael D; Winters, Michael E
2017-10-01
High-quality chest compressions are a critical component of the resuscitation of patients in cardiopulmonary arrest. Point-of-care ultrasound (POCUS) is used frequently during emergency department (ED) resuscitations, but there has been limited research assessing its benefits and harms during the delivery of cardiopulmonary resuscitation (CPR). We hypothesized that use of POCUS during cardiac arrest resuscitation adversely affects high-quality CPR by lengthening the duration of pulse checks beyond the current cardiopulmonary resuscitation guidelines recommendation of 10s. We conducted a prospective cohort study of adults in cardiac arrest treated in an urban ED between August 2015 and September 2016. Resuscitations were recorded using video equipment in designated resuscitation rooms, and the use of POCUS was documented and timed. A linear mixed-effects model was used to estimate the effect of POCUS on pulse check duration. Twenty-three patients were enrolled in our study. The mean duration of pulse checks with POCUS was 21.0s (95% CI, 18-24) compared with 13.0s (95% CI, 12-15) for those without POCUS. POCUS increased the duration of pulse checks and CPR interruption by 8.4s (95% CI, 6.7-10.0 [p<0.0001]). Age, body mass index (BMI), and procedures did not significantly affect the duration of pulse checks. The use of POCUS during cardiac arrest resuscitation was associated with significantly increased duration of pulse checks, nearly doubling the 10-s maximum duration recommended in current guidelines. It is important for acute care providers to pay close attention to the duration of interruptions in the delivery of chest compressions when using POCUS during cardiac arrest resuscitation. Copyright © 2017 Elsevier B.V. All rights reserved.
Lukas, Roman-Patrik; Van Aken, Hugo; Mölhoff, Thomas; Weber, Thomas; Rammert, Monika; Wild, Elke; Bohn, Andreas
2016-04-01
This prospective longitudinal study over 6 years compared schoolteachers and emergency physicians as resuscitation trainers for schoolchildren. It also investigated whether pupils who were trained annually for 3 years retain their resuscitation skills after the end of this study. A total of 261 pupils (fifth grade) at two German grammar schools received resuscitation training by trained teachers or by emergency physicians. The annual training events stopped after 3 years in one group and continued for 6 years in a second group. We measured knowledge about resuscitation (questionnaire), chest compression rate (min(-1)), chest compression depth (mm), ventilation rate (min(-1)), ventilation volume (mL), self-efficacy (questionnaire). Their performance was evaluated after 1, 3 and 6 years. The training events increased the pupils' knowledge and practical skills. When trained by teachers, the pupils achieved better results for knowledge (92.86% ± 8.38 vs. 90.10% ± 8.63, P=0.04) and ventilation rate (4.84/min ± 4.05 vs. 3.76/min ± 2.37, P=0.04) than when they were trained by emergency physicians. There were no differences with regard to chest compression rate, depth, ventilation volume, or self-efficacy at the end of the study. Knowledge and skills after 6 years were equivalent in the group with 6 years training compared with 3 years training. Trained teachers can provide adequate resuscitation training in schools. Health-care professionals are not mandatory for CPR training (easier for schools to implement resuscitation training). The final evaluation after 6 years showed that resuscitation skills are retained even when training is interrupted for 3 years. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Barriers to dispatcher-assisted cardiopulmonary resuscitation in Singapore.
Ho, Andrew Fu Wah; Sim, Zariel Jiaying; Shahidah, Nur; Hao, Ying; Ng, Yih Yng; Leong, Benjamin S H; Zarinah, Siti; Teo, Winston K L; Goh, Geraldine Shu Yi; Jaafar, Hamizah; Ong, Marcus E H
2016-08-01
Dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) is effective in increasing bystander CPR in out-of-hospital cardiac arrests (OHCA). Singapore has recently implemented a DA-CPR program. We aimed to characterize barriers to commencement of chest compressions by callers in Singapore. We analyzed dispatch recordings of OHCA cases received by the ambulance call center between July 2012 and March 2015. Audio recordings of poor quality were excluded. Trained reviewers noted the sequential stages of the dispatcher's recognition of CPR, delivering CPR instructions and caller performing CPR. Time taken to reach these milestones was noted. Barriers to chest compressions were identified. A total of 4897 OHCA occurred during the study period, overall bystander CPR rate was 45.7%. 1885 dispatch recordings were reviewed with 1157 cases qualified for dispatcher CPR. In 1128 (97.5%) cases, the dispatcher correctly recognized the need for CPR. CPR instructions were delivered in 1056 (91.3%) cases. Of these, 1007 (87.0%) callers performed CPR to instruction. One or more barriers to chest compressions were identified in 430 (37.2%) cases. The commonest barrier identified was "could not move patient" (27%). Cases where barriers were identified were less likely to have the need for CPR recognized by the dispatcher (94.9% vs. 99.0%, p<0.001), CPR instructions given (79.3% vs. 98.3%, p<0.001) and CPR started (67.9% vs. 98.3%, p<0.001), while the time taken to reach each of these stages were significantly longer (p<0.001). Barriers were present in 37% of cases. They were associated with lower proportion of CPR started and longer delay to CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Bleijenberg, Eduard; Koster, Rudolph W; de Vries, Hendrik; Beesems, Stefanie G
2017-01-01
The Guidelines place emphasis on high-quality cardiopulmonary resuscitation (CPR). This study aims to measure the impact of post-resuscitation feedback on the quality of CPR as performed by ambulance personnel. Two ambulances are dispatched for suspected cardiac arrest. The crew (driver and paramedic) of the first arriving ambulance is responsible for the quality of CPR. The crew of the second ambulance establishes an intravenous access and supports the first crew. All resuscitation attempts led by the ambulance crew of the study region were reviewed by two research paramedics and structured feedback was given based on defibrillator recording with impedance signal. A 12-months period before introduction of post-resuscitation feedback was compared with a 19-months period after introduction of feedback, excluding a six months run-in interval. Quality parameters were chest compression fraction (CCF), chest compression rate, longest peri-shock pause and longest non-shock pause. In the pre-feedback period 55 cases were analyzed and 69 cases in the feedback period. Median CCF improved significantly in the feedback period (79% vs 86%, p<0.001). The mean chest compression rate was within the recommended range of 100-120/min in 87% of the cases in the pre-feedback period and in 90% of the cases in the feedback period (p=0.65). The duration of longest non-shock pause decreased significantly (40s vs 19s, p<0.001), the duration of the longest peri-shock pause did not change significantly (16s vs 13s, p=0.27). Post-resuscitation feedback improves the quality of resuscitation, significantly increasing CCF and decreasing the duration of longest non-shock pauses. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Schuerner, Philipp; Grande, Bastian; Piegeler, Tobias; Schlaepfer, Martin; Saager, Leif; Hutcherson, Matthew T; Spahn, Donat R; Ruetzler, Kurt
2016-01-01
Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been introduced to better visualize the vocal cords and accelerate intubation, which makes endotracheal intubation much safer and may contribute to intubation success. Therefore, we aimed to compare hands-off time and intubation success of direct laryngoscopy with videolaryngoscopy (C-MAC, Karl Storz, Tuttlingen, Germany) in a randomized, cross-over manikin study. Twenty-six anesthesia residents and twelve anesthesia consultants of the University Hospital Zurich were recruited through a voluntary enrolment. All participants performed endotracheal intubation using direct laryngoscopy and C-MAC in a random order during ongoing chest compressions. Participants were strictly advised to stop chest compression only if necessary. The median hands-off time was 1.9 seconds in direct laryngoscopy, compared to 3 seconds in the C-MAC group. In direct laryngoscopy 39 intubation attempts were recorded, resulting in an overall first intubation attempt success rate of 97%, compared to 38 intubation attempts and 100% overall first intubation attempt success rate in the C-MAC group. As a conclusion, the results of our manikin-study demonstrate that video laryngoscopes might not be beneficial compared to conventional, direct laryngoscopy in easily accessible airways under CPR conditions and in experienced hands. The benefits of video laryngoscopes are of course more distinct in overcoming difficult airways, as it converts a potential "blind intubation" into an intubation under visual control.
Zhang, Yan; Yue, Tianxue; Sun, Kexin; Wang, Jiang; Zhu, Ruiwu
2018-05-01
The new cardiopulmonary resuscitation (CPR) guideline emphasize the importance of chest compression, which was considered as the first step to CPR. The duration for CPR is usually limited to 30 minutes. With the development of new technology and evidence-based medicine, the success of extra longtime CPR has become possible, which is of great significance to some patients with cardiac arrest (CA), but the time limit has not been determined. On February 23rd in 2016, a 76-year-old female patient with respiratory and cardiac arrest who was on the third day after transurethral resection of bladder tumor (TUR-BT) was admitted to the intensive care unit of the General Hospital of Fushun Mining Bureau. On the basis of the comprehensive treatment measures such as ventilator support ventilation, physical cooling with ice cap, 1 mg adrenaline for intravenous injection, low molecular heparin of 5 000 U for subcutaneous injection, and the continuous chest compression were carried out in a timely and effective manner for 125 minutes, which make the patient recover to sinus rhythm and her brain function recovered well without any sequelae, and follow-up of the patient in 1 year showed well. The key to success or failure of CPR depend on the patient's condition. If the patients in healthy, single cause, a good response to the resuscitation, the pulsation of the large artery can be seen now and then during the rescue, and the recovery of the spontaneous breathing, CPR should be kept on. In the process of CPR, individualized assessment of the disease progression without the 30-minute time limit, may benefit the patients in maximum. In the future clinical practice, we should actively explore more favorable evidence, so that CA patients can be rescued more.
Schröder, J; Bucher, M; Meyer, O
2016-09-01
Intubation with a laryngeal tube (LT) is a recommended alternative to endotracheal intubation during advanced life support (ALS). LT insertion is easy; therefore, it may also be an alternative to bag-mask ventilation (BMV) for untrained personnel performing basic life support (BLS). Data from manikin studies support the influence of LT on no-flow-time (NFT) during ALS. We performed a prospective, randomized manikin study using a two-rescuer model to compare the effects of ventilation using a LT and BMV on NFT during BLS. Participants were trained in BMV and were inexperienced in the use of a LT. There was no significant difference in total NFT with the use of a LT and BMV (LT: mean 83.1 ± 37.3 s; BMV: mean 78.7 ± 24.5 s; p = 0.313), but we found significant differences in the progression of the scenario: in the BLS-scenario, the proportion of time spent performing chest compressions was higher when BMV was used compared to when a LT was used. The quality of chest compressions and the ventilation rate did not differ significantly between the two groups. The mean tidal volume and mean minute volume were significantly larger with the use of a LT compared with the use of BMV. In conclusion, in a two-rescuer BLS scenario, NFT is longer with the use of a LT (without prior training) than with the use of BMV (with prior training). The probable reasons for this result are higher tidal volumes with the use of a LT leading to longer interruptions without chest compressions.
Meyer, O; Bucher, M; Schröder, J
2016-03-01
The laryngeal tube (LT) is a recommended alternative to endotracheal intubation during advanced life support (ALS). Its insertion is relatively simple; therefore, it may also serve as an alternative to bag mask ventilation (BMV) for untrained personnel performing basic life support (BLS). Data support the influence of LT on the no-flow time (NFT) compared with BMV during ALS in manikin studies. We performed a manikin study to investigate the effect of using the LT for ventilation instead of BMV on the NFT during BLS in a prospective, randomized, single-rescuer study. All 209 participants were trained in BMV, but were inexperienced in using LT; each participant performed BLS during a 4-min time period. No significant difference in total NFT (LT: mean 81.1 ± 22.7 s; BMV: mean 83.2 ± 13.1 s, p = 0.414) was found; however, significant differences in the later periods of the scenario were identified. While ventilating with the LT, the proportion of chest compressions increased significantly from 67.2 to 73.2%, whereas the proportion of chest compressions increased only marginally when performing BMV. The quality of the chest compressions and the associated ventilation rate did not differ significantly. The mean tidal volume and mean minute volume were significantly lower when performing BMV. The NFT was significantly shorter in the later periods in a single-rescuer, cardiac arrest scenario when using an LT without previous training compared with BMV with previous training. A possible explanation for this result may be the complexity and workload of alternating tasks (e.g., time loss when reclining the head and positioning the mask for each ventilation during BMV).
Varela, Gonzalo; Jiménez, Marcelo F; Novoa, Nuria Maria; Aranda, José Luis
2009-01-01
Since there are no data in the literature regarding variability in the management of postoperative pleural drainages, we have designed a prospective randomized study aimed at measuring inter-observer variability in deciding when to withdraw chest tubes after lung resection and to evaluate if the use of an electronic device to measure postoperative air leak decreases clinical practice variations. Sixty-one patients undergoing pulmonary resection were randomly assigned to one of the following groups: digital group (electronic measure of pleural air leak using Millicore AB DigiVent chest drainage system) or traditional group (standard water seal pleural chamber). Chest tube withdrawal criteria were established in advance. During morning rounds, two thoracic surgeons with comparable clinical experience and blinded to the decision of their counterpart, evaluated chest tube withdrawal criteria and noted whether the tube should be withdrawn or not. Inter-observer variability kappa index and global, positive, and negative agreement rates were calculated on 2 x 2 tables. Each observation episode was considered in the calculation. Fifty-four observations were recorded in the traditional group. Kappa coefficient was 0.37 (overall agreement rate: 0.58; positive agreement rate: 0.72; and negative agreement rate: 0.64). In the digital group, 67 observations were recorded. Kappa coefficient was 0.88 (overall agreement rate: 0.94; positive agreement rate 0.94; and negative agreement rate 0.94). We have demonstrated a high rate of disagreement related to the indication to remove chest tubes after lung resection and the improvement of the agreement rate with the use of an electronic device to measure postoperative air leak and pleural pressures.
Jayaram, Archana; Sima, Adam; Barker, Gail; Thacker, Leroy R
2013-07-01
Manual ventilation in the delivery room is provided with devices such as self-inflating bags (SIBs), flow-inflating bags, and T-piece resuscitators. To compare the effect of type of manual ventilation device on overall response to resuscitation among preterm neonates born at < 35 weeks gestation. Retrospective data were collected in 2 time periods. Primary outcome was overall response to resuscitation, as measured by Apgar score. Secondary outcomes were incidence of air leaks, need for chest compressions/epinephrine, need for intubation, and surfactant use. We identified 294 resuscitations requiring ventilation. SIB was used for 135 neonates, and T-piece was used for 159 neonates. There was no significant difference between the 1-min and 5-min Apgar scores between SIB and T-piece (P = .77 and P = .11, respectively), nor were there significant differences in secondary outcomes. The rate of rise of Apgar score was higher, by 0.47, with T-piece, compared to SIB (95% CI 0.08-0.87, P = .02). Although some manikin studies favor T-piece for providing reliable and consistent pressures, our experience did not indicate significant differences in effectiveness of resuscitation between the T-piece and SIB in preterm resuscitations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay; Ensor, Joe E.
PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if themore » absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.« less
Leung, Chung Ming; Or, Siu Wing; Ho, S L
2013-12-01
A force sensing device capable of sensing dc (or static) compressive forces is developed based on a NAS106N stainless steel compressive spring, a sintered NdFeB permanent magnet, and a coil-wound Tb(0.3)Dy(0.7)Fe(1.92)/Pb(Zr, Ti)O3 magnetostrictive∕piezoelectric laminate. The dc compressive force sensing in the device is evaluated theoretically and experimentally and is found to originate from a unique force-induced, position-dependent, current-driven dc magnetoelectric effect. The sensitivity of the device can be increased by increasing the spring constant of the compressive spring, the size of the permanent magnet, and/or the driving current for the coil-wound laminate. Devices of low-force (20 N) and high-force (200 N) types, showing high output voltages of 262 and 128 mV peak, respectively, are demonstrated at a low driving current of 100 mA peak by using different combinations of compressive spring and permanent magnet.
Cho, Hyun Min; Hong, Yoon Joo; Byun, Chun Sung; Hwang, Jung Joo
2016-03-01
Chest drainage systems are usually composed of chest tube and underwater-seal bottle. But this conventional system may restrict patients doing exercise and give clinicians obscure data about when to remove tubes because there is no objective indicator. Recently developed digital chest drainage systems may facilitate interpretation of the grade of air leak and make it easy for clinicians to decide when to remove chest tubes. In addition, with combination of wireless internet devices, monitoring and managing of drainage system distant from the patient is possible. Sixty patients of primary pneumothorax were included in a prospective randomized study and divided into two groups. Group I (study) consisted of digital chest drainage system while in group II (control), conventional underwater-seal chest bottle system was used. Data was collected from January, 2012 to September, 2013 in Eulji University Hospital, Daejeon, Korea. There was no difference in age, sex, smoking history and postoperative pain between two groups. But the average length of drainage was 2.2 days in group I and 3.1 days in group II (P<0.006). And more, about 90% of the patients in group I was satisfied with using new device for convenience. Digital system was beneficial on reducing the length of tube drainage by real time monitoring. It also had advantage in portability, loudness and gave more satisfaction than conventional system. Moreover, internet based digital drainage system will be a good method in thoracic telemedicine area in the near future.
Weir, Christopher J.; Rubio, Noah; Rabinovich, Roberto; Pinnock, Hilary; Hanley, Janet; McCloughan, Lucy; Drost, Ellen M.; Mantoani, Leandro C.; MacNee, William; McKinstry, Brian
2016-01-01
Introduction The Bland-Altman limits of agreement method is widely used to assess how well the measurements produced by two raters, devices or systems agree with each other. However, mixed effects versions of the method which take into account multiple sources of variability are less well described in the literature. We address the practical challenges of applying mixed effects limits of agreement to the comparison of several devices to measure respiratory rate in patients with chronic obstructive pulmonary disease (COPD). Methods Respiratory rate was measured in 21 people with a range of severity of COPD. Participants were asked to perform eleven different activities representative of daily life during a laboratory-based standardised protocol of 57 minutes. A mixed effects limits of agreement method was used to assess the agreement of five commercially available monitors (Camera, Photoplethysmography (PPG), Impedance, Accelerometer, and Chest-band) with the current gold standard device for measuring respiratory rate. Results Results produced using mixed effects limits of agreement were compared to results from a fixed effects method based on analysis of variance (ANOVA) and were found to be similar. The Accelerometer and Chest-band devices produced the narrowest limits of agreement (-8.63 to 4.27 and -9.99 to 6.80 respectively) with mean bias -2.18 and -1.60 breaths per minute. These devices also had the lowest within-participant and overall standard deviations (3.23 and 3.29 for Accelerometer and 4.17 and 4.28 for Chest-band respectively). Conclusions The mixed effects limits of agreement analysis enabled us to answer the question of which devices showed the strongest agreement with the gold standard device with respect to measuring respiratory rates. In particular, the estimated within-participant and overall standard deviations of the differences, which are easily obtainable from the mixed effects model results, gave a clear indication that the Accelerometer and Chest-band devices performed best. PMID:27973556
Cheskes, Sheldon; Schmicker, Robert H; Rea, Tom; Morrison, Laurie J; Grunau, Brian; Drennan, Ian R; Leroux, Brian; Vaillancourt, Christian; Schmidt, Terri A; Koller, Allison C; Kudenchuk, Peter; Aufderheide, Tom P; Herren, Heather; Flickinger, Katharyn H; Charleston, Mark; Straight, Ron; Christenson, Jim
2017-07-01
Measures of chest compression fraction (CCF), compression rate, compression depth and pre-shock pause have all been independently associated with improved outcomes from out-of-hospital (OHCA) cardiac arrest. However, it is unknown whether compliance with American Heart Association (AHA) guidelines incorporating all the aforementioned metrics, is associated with improved survival from OHCA. We performed a secondary analysis of prospectively collected data from the Resuscitation Outcomes Consortium Epistry-Cardiac Arrest database. As per the 2015 American Heart Association (AHA) guidelines, guideline compliant cardiopulmonary resuscitation (CPR) was defined as CCF >0.8, chest compression rate 100-120/minute, chest compression depth 50-60mm, and pre-shock pause <10s. Multivariable logistic regression models controlling for Utstein variables were used to assess the relationship between global guideline compliance and survival to hospital discharge and neurologically intact survival with MRS ≤3. Due to potential confounding between CPR quality metrics and cases that achieved early ROSC, we performed an a priori subgroup analysis restricted to patients who obtained ROSC after ≥10min of EMS resuscitation. After allowing for study exclusions, 19,568 defibrillator records were collected over a 4-year period ending in June 2015. For all reported models, the reference standard included all cases who did not meet all CPR quality benchmarks. For the primary model (CCF, rate, depth), there was no significant difference in survival for resuscitations that met all CPR quality benchmarks (guideline compliant) compared to the reference standard (OR 1.26; 95% CI: 0.80, 1.97). When the dataset was restricted to patients obtaining ROSC after ≥10min of EMS resuscitation (n=4,158), survival was significantly higher for those resuscitations that were guideline compliant (OR 2.17; 95% CI: 1.11, 4.27) compared to the reference standard. Similar findings were obtained for neurologically intact survival with MRS ≤3 (OR 3.03; 95% CI: 1.12, 8.20). In this observational study, compliance with AHA guidelines for CPR quality was not associated with improved outcomes from OHCA. Conversely, when restricting the cohort to those with late ROSC, compliance with guidelines was associated with improved clinical outcomes. Strategies to improve overall guideline compliance may have a significant impact on outcomes from OHCA. Copyright © 2017 Elsevier B.V. All rights reserved.
Why do some studies find that CPR fraction is not a predictor of survival?
Wik, Lars; Olsen, Jan-Aage; Persse, David; Sterz, Fritz; Lozano, Michael; Brouwer, Marc A; Westfall, Mark; Souders, Chris M; Travis, David T; Herken, Ulrich R; Lerner, E Brooke
2016-07-01
An 80% chest compression fraction (CCF) during resuscitation is recommended. However, heterogeneous results in CCF studies were found during the 2015 Consensus on Science (CoS), which may be because chest compressions are stopped for a wide variety of reasons including providing lifesaving care, provider distraction, fatigue, confusion, and inability to perform lifesaving skills efficiently. The effect of confounding variables on CCF to predict cardiac arrest survival. A secondary analysis of emergency medical services (EMS) treated out-of-hospital cardiac arrest (OHCA) patients who received manual compressions. CCF (percent of time patients received compressions) was determined from electronic defibrillator files. Two Sample Wilcoxon Rank Sum or regression determined a statistical association between CCF and age, gender, bystander CPR, public location, witnessed arrest, shockable rhythm, resuscitation duration, study site, and number of shocks. Univariate and multivariate logistic regressions were used to determine CCF effect on survival. Of 2132 patients with manual compressions 1997 had complete data. Shockable rhythm (p<0.001), public location (p<0.004), treatment duration (p<0.001), and number of shocks (p<0.001) were associated with lower CCF. Univariate logistic regression found that CCF was inversely associated with survival (OR 0.07; 95% CI 0.01-0.36). Multivariate regression controlling for factors associated with survival and/or CCF found that increasing CCF was associated with survival (OR 6.34; 95% CI 1.02-39.5). CCF cannot be looked at in isolation as a predictor of survival, but in the context of other resuscitation activities. When controlling for the effects of other resuscitation activities, a higher CCF is predictive of survival. This may explain the heterogeneity of findings during the CoS review. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Baldi, Enrico; Contri, Enrico; Burkart, Roman; Borrelli, Paola; Ferraro, Ottavia Eleonora; Tonani, Michela; Cutuli, Amedeo; Bertaia, Daniele; Iozzo, Pasquale; Tinguely, Caroline; Lopez, Daniel; Boldarin, Susi; Deiuri, Claudio; Dénéréaz, Sandrine; Dénéréaz, Yves; Terrapon, Michael; Tami, Christian; Cereda, Cinzia; Somaschini, Alberto; Cornara, Stefano; Cortegiani, Andrea
2018-04-19
Out-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR. This is a prospective randomised trial performed in eight training centres. Laypeople who passed a basic life support course will be randomised to one of the four CPR protocols in an 8 min simulated cardiac arrest scenario on a manikin: (1) 30 compressions and 2 s pause; (2) 50 compressions and 5 s pause; (3) 100 compressions and 10 s pause; (4) hands-only. The calculated sample size is 552 people. The primary outcome is the percentage of chest compression performed with correct depth evaluated by a computerised feedback system (Laerdal QCPR). ETHICS AND DISSEMINATION: . Due to the nature of the study, we obtained a waiver from the Ethics Committee (IRCCS Policlinico San Matteo, Pavia, Italy). All participants will sign an informed consent form before randomisation. The results of this study will be published in peer-reviewed journal. The data collected will also be made available in a public data repository. NCT02632500. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Gregson, Rachael K; Shannon, Harriet; Stocks, Janet; Cole, Tim J; Peters, Mark J; Main, Eleanor
2012-03-01
This study aimed to quantify the specific effects of manual lung inflations with chest compression-vibrations, commonly used to assist airway clearance in ventilated patients. The hypothesis was that force applied during the compressions made a significant additional contribution to increases in peak expiratory flow and expiratory to inspiratory flow ratio over and above that resulting from accompanying increases in inflation volume. Prospective observational study. Cardiac and general pediatric intensive care. Sedated, fully ventilated children. Customized force-sensing mats and a commercial respiratory monitor recorded force and respiration during physiotherapy. Percentage changes in peak expiratory flow, peak expiratory to inspiratory flow ratios, inflation volume, and peak inflation pressure between baseline and manual inflations with and without compression-vibrations were calculated. Analysis of covariance determined the relative contribution of changes in pressure, volume, and force to influence changes in peak expiratory flow and peak expiratory to inspiratory flow ratio. Data from 105 children were analyzed (median age, 1.3 yrs; range, 1 wk to 15.9 yrs). Force during compressions ranged from 15 to 179 N (median, 46 N). Peak expiratory flow increased on average by 76% during compressions compared with baseline ventilation. Increases in peak expiratory flow were significantly related to increases in inflation volume, peak inflation pressure, and force with peak expiratory flow increasing by, on average, 4% for every 10% increase in inflation volume (p < .001), 5% for every 10% increase in peak inflation pressure (p = .005), and 3% for each 10 N of applied force (p < .001). By contrast, increase in peak expiratory to inspiratory flow ratio was only related to applied force with a 4% increase for each 10 N of force (p < .001). These results provide evidence of the unique contribution of compression forces in increasing peak expiratory flow and peak expiratory to inspiratory flow ratio bias over and above that related to accompanying changes from manual hyperinflations. Force generated during compression-vibrations was the single significant factor in multivariable analysis to explain the increases in expiratory flow bias. Such increases in the expiratory bias provide theoretically optimal physiological conditions for cephalad mucus movement in fully ventilated children.
Evaluation of the field relevance of several injury risk functions.
Prasad, Priya; Mertz, Harold J; Dalmotas, Danius J; Augenstein, Jeffrey S; Diggs, Kennerly
2010-11-01
An evaluation of the four injury risk curves proposed in the NHTSA NCAP for estimating the risk of AIS>= 3 injuries to the head, neck, chest and AIS>=2 injury to the Knee-Thigh-Hip (KTH) complex has been conducted. The predicted injury risk to the four body regions based on driver dummy responses in over 300 frontal NCAP tests were compared against those to drivers involved in real-world crashes of similar severity as represented in the NASS. The results of the study show that the predicted injury risks to the head and chest were slightly below those in NASS, and the predicted risk for the knee-thigh-hip complex was substantially below that observed in the NASS. The predicted risk for the neck by the Nij curve was greater than the observed risk in NASS by an order of magnitude due to the Nij risk curve predicting a non-zero risk when Nij = 0. An alternative and published Nte risk curve produced a risk estimate consistent with the NASS estimate of neck injury. Similarly, an alternative and published chest injury risk curve produced a risk estimate that was within the bounds of the NASS estimates. No published risk curve for femur compressive load could be found that would give risk estimates consistent with the range of the NASS estimates. Additional work on developing a femur compressive load risk curve is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin
PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complicationsmore » were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.« less
Ultra-flexible Piezoelectric Devices Integrated with Heart to Harvest the Biomechanical Energy
Lu, Bingwei; Chen, Ying; Ou, Dapeng; Chen, Hang; Diao, Liwei; Zhang, Wei; Zheng, Jun; Ma, Weiguo; Sun, Lizhong; Feng, Xue
2015-01-01
Power supply for medical implantable devices (i.e. pacemaker) always challenges not only the surgery but also the battery technology. Here, we report a strategy for energy harvesting from the heart motion by using ultra-flexible piezoelectric device based on lead zirconate titanate (PZT) ceramics that has most excellent piezoelectricity in commercial materials, without any burden or damage to hearts. Experimental swine are selected for in vivo test with different settings, i.e. opened chest, close chest and awake from anesthesia, to simulate the scenario of application in body due to their hearts similar to human. The results show the peak-to-peak voltage can reach as high as 3 V when the ultra-flexible piezoelectric device is fixed from left ventricular apex to right ventricle. This demonstrates the possibility and feasibility of fully using the biomechanical energy from heart motion in human body for sustainably driving implantable devices. PMID:26538375
Ultra-flexible Piezoelectric Devices Integrated with Heart to Harvest the Biomechanical Energy
NASA Astrophysics Data System (ADS)
Lu, Bingwei; Chen, Ying; Ou, Dapeng; Chen, Hang; Diao, Liwei; Zhang, Wei; Zheng, Jun; Ma, Weiguo; Sun, Lizhong; Feng, Xue
2015-11-01
Power supply for medical implantable devices (i.e. pacemaker) always challenges not only the surgery but also the battery technology. Here, we report a strategy for energy harvesting from the heart motion by using ultra-flexible piezoelectric device based on lead zirconate titanate (PZT) ceramics that has most excellent piezoelectricity in commercial materials, without any burden or damage to hearts. Experimental swine are selected for in vivo test with different settings, i.e. opened chest, close chest and awake from anesthesia, to simulate the scenario of application in body due to their hearts similar to human. The results show the peak-to-peak voltage can reach as high as 3 V when the ultra-flexible piezoelectric device is fixed from left ventricular apex to right ventricle. This demonstrates the possibility and feasibility of fully using the biomechanical energy from heart motion in human body for sustainably driving implantable devices.
Cho, Hyun Min; Hong, Yoon Joo; Byun, Chun Sung
2016-01-01
Background Chest drainage systems are usually composed of chest tube and underwater-seal bottle. But this conventional system may restrict patients doing exercise and give clinicians obscure data about when to remove tubes because there is no objective indicator. Recently developed digital chest drainage systems may facilitate interpretation of the grade of air leak and make it easy for clinicians to decide when to remove chest tubes. In addition, with combination of wireless internet devices, monitoring and managing of drainage system distant from the patient is possible. Methods Sixty patients of primary pneumothorax were included in a prospective randomized study and divided into two groups. Group I (study) consisted of digital chest drainage system while in group II (control), conventional underwater-seal chest bottle system was used. Data was collected from January, 2012 to September, 2013 in Eulji University Hospital, Daejeon, Korea. Results There was no difference in age, sex, smoking history and postoperative pain between two groups. But the average length of drainage was 2.2 days in group I and 3.1 days in group II (P<0.006). And more, about 90% of the patients in group I was satisfied with using new device for convenience. Conclusions Digital system was beneficial on reducing the length of tube drainage by real time monitoring. It also had advantage in portability, loudness and gave more satisfaction than conventional system. Moreover, internet based digital drainage system will be a good method in thoracic telemedicine area in the near future. PMID:27076934
Analyzing non-respiratory movements of the chest: methods and devices
NASA Astrophysics Data System (ADS)
Pariaszewska, Katarzyna; Młyńczak, Marcel; Cybulski, Gerard
2015-09-01
Respiration is the main reason of the chest movements. However, there are also non-respiratory ones, resulting from e.g. snoring, wheezing, stridor, throat clearing or coughing. They may exist sporadically, however should be examined in case when their incidences increase. Detecting non-respiratory movements is very important, because many of them are symptoms of respiratory diseases such as asthma, chronic obstructive pulmonary disease (COPD) or lung cancer. Assessment of the presence of non-respiratory movements could be important element of effective diagnosis. It is also necessary to provide quantitative and objective results for intra-subject studies. Most of these events generate vibroacoustic signals that contain components of sound and vibrations. This work provides the review of the solutions and devices for monitoring of the non-respiratory movements, primarily considering the accuracy of the chest movements' detection and distinguishing.
NASA Technical Reports Server (NTRS)
Hurst, Victor, IV; West, Sarah; Austin, Paul; Branson, Richard; Beck, George
2006-01-01
Astronaut crew medical officers (CMO) aboard the International Space Station (ISS) receive 40 hours of medical training during the 18 months preceding each mission. Part of this training ilncludes twoperson cardiopulmonary resuscitation (CPR) per training guidelines from the American Heart Association (AHA). Recent studies concluded that the use of metronomic tones improves the coordination of CPR by trained clinicians. Similar data for bystander or "trained lay people" (e.g. CMO) performance of CPR (BCPR) have been limited. The purpose of this study was to evailuate whether use of timing devices, such as audible metronomic tones, would improve BCPR perfomance by trained bystanders. Twenty pairs of bystanders trained in two-person BCPR performled BCPR for 4 minutes on a simulated cardiopulmonary arrest patient using three interventions: 1) BCPR with no timing devices, 2) BCPR plus metronomic tones for coordinating compression rate only, 3) BCPR with a timing device and metronome for coordinating ventilation and compression rates, respectively. Bystanders were evaluated on their ability to meet international and AHA CPR guidelines. Bystanders failed to provide the recommended number of breaths and number of compressions in the absence of a timing device and in the presence of audible metronomic tones for only coordinating compression rate. Bystanders using timing devices to coordinate both components of BCPR provided the reco number of breaths and were closer to providing the recommended number of compressions compared with the other interventions. Survey results indicated that bystanders preferred to use a metronome for delivery of compressions during BCPR. BCPR performance is improved by timing devices that coordinate both compressions and breaths.
Bertolaccini, Luca; Rizzardi, Giovanna; Filice, Mary Jo; Terzi, Alberto
2011-05-01
Until now, only way to report air leaks (ALs) has been with an analogue score in an inherently subjective manner. The Six Sigma quality improvement methodology is a data-driven approach applicable to evaluate the quality of the quantification method of repetitive procedures. We applied the Six Sigma concept to improve the process of AL evaluation. A digital device for AL measurement (Drentech PALM, Redax S.r.l., Mirandola (MO), Italy) was applied to 49 consecutive patients, who underwent pulmonary intervention, compared with a similar population with classical chest drainage. Data recorded were postoperative AL, chest-tube removal days, number of chest roentgenograms, hospital length of stay; device setup time, average time rating AL and patient satisfaction. Bivariable comparisons were made using the Mann-Whitney test, the χ² test and Fisher's exact test. Analysis of quality was conducted using the Six Sigma methodology. There were no significant differences regarding AL (p=0.075), although not statistically significant; there was a reduction of postoperative chest X-rays (four vs five) and of hospital length of stay (6.5 vs 7.1 days); and a marginally significant difference was found between chest-tube removal days (p=0.056). There were significant differences regarding device setup time (p=0.001), average time rating AL (p=0.001), inter-observer variability (p=0.001) and patient satisfaction (p=0.002). Six Sigma analyses revealed accurate assessment of AL. Continuous digital measurement of AL reduces degree of variability of AL score, gives more assurance for tube removal, and reports AL without the apprehension of observer error. Efficiency and effectiveness improved with the use of a digital device. We have noted that the AL curves depict actually sealing of AL. The clinical importance of AL curves requires further study. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Non-censored rib fracture data during frontal PMHS sled tests.
Kemper, Andrew R; Beeman, Stephanie M; Porta, David J; Duma, Stefan M
2016-09-01
The purpose of this study was to obtain non-censored rib fracture data due to three-point belt loading during dynamic frontal post-mortem human surrogate (PMHS) sled tests. The PMHS responses were then compared to matched tests performed using the Hybrid-III 50(th) percentile male ATD. Matched dynamic frontal sled tests were performed on two male PMHSs, which were approximately 50(th) percentile height and weight, and the Hybrid-III 50(th) percentile male ATD. The sled pulse was designed to match the vehicle acceleration of a standard sedan during a FMVSS-208 40 kph test. Each subject was restrained with a 4 kN load limiting, driver-side, three-point seatbelt. A 59-channel chestband, aligned at the nipple line, was used to quantify the chest contour, anterior-posterior sternum deflection, and maximum anterior-posterior chest deflection for all test subjects. The internal sternum deflection of the ATD was quantified with the sternum potentiometer. For the PMHS tests, a total of 23 single-axis strain gages were attached to the bony structures of the thorax, including the ribs, sternum, and clavicle. In order to create a non-censored data set, the time history of each strain gage was analyzed to determine the timing of each rib fracture and corresponding timing of each AIS level (AIS = 1, 2, 3, etc.) with respect to chest deflection. Peak sternum deflection for PMHS 1 and PMHS 2 were 48.7 mm (19.0%) and 36.7 mm (12.2%), respectively. The peak sternum deflection for the ATD was 20.8 mm when measured by the chest potentiometer and 34.4 mm (12.0%) when measured by the chestband. Although the measured ATD sternum deflections were found to be well below the current thoracic injury criterion (63 mm) specified for the ATD in FMVSS-208, both PMHSs sustained AIS 3+ thoracic injuries. For all subjects, the maximum chest deflection measured by the chestband occurred to the right of the sternum and was found to be 83.0 mm (36.0%) for PMHS 1, 60.6 mm (23.9%) for PMHS 2, and 56.3 mm (20.0%) for the ATD. The non-censored rib fracture data in the current study (n = 2 PMHS) in conjunction with the non-censored rib fracture data from two previous table-top studies (n = 4 PMHS) show that AIS 3+ injury timing occurs prior to peak sternum compression, prior to peak maximum chest compression, and at lower compressions than might be suggested by current PMHS thoracic injury criteria developed using censored rib fracture data. In addition, the maximum chest deflection results showed a more reasonable correlation between deflection, rib fracture timing, and injury severity than sternum deflection. Overall, these data provide compelling empirical evidence that suggests a more conservative thoracic injury criterion could potentially be developed based on non-censored rib fracture data with additional testing performed over a wider range of subjects and loading conditions.
Chang, Angela T; Palmer, Kerry R; McNaught, Jessie; Thomas, Peter J
2010-08-01
This study investigated the effect of flow rates and spirometer type on chest wall motion in healthy individuals. Twenty-one healthy volunteers completed breathing trials to either two times tidal volume (2xV(T)) or inspiratory capacity (IC) at high, low, or natural flow rates, using a volume- or flow-oriented spirometer. The proportions of rib cage movement to tidal volume (%RC/V(T)), chest wall diameters, and perceived level of exertion (RPE) were compared. Low and natural flow rates resulted in significantly lower %RC/V(T) compared to high flow rate trials (p=0.001) at 2xV(T). Low flow trials also resulted in significantly less chest wall motion in the upper anteroposterior direction than high and natural flow rates (p<0.001). At IC, significantly greater movement occurred in the abdominal lateral direction during low flow compared to high and natural flow trials (both p<0.003). RPE was lower for the low flow trials compared to high flow trials at IC and 2xV(T) (p<0.01). In healthy individuals, inspiratory flow (not device type) during incentive spirometry determines the resultant breathing pattern. High flow rates result in greater chest wall motion than low flow rates.
Treatment of atelectasis: where is the evidence?
Schindler, Margrid B
2005-01-01
Lobar atelectasis is a common problem caused by a variety of mechanisms including resorption atelectasis due to airway obstruction, passive atelectasis from hypoventilation, compressive atelectsis from abdominal distension and adhesive atelectasis due to increased surface tension. However, evidence-based studies on the management of lobar atelectasis are lacking. Examination of air-bronchograms on a chest radiograph may be helpful to determine whether proximal or distal airway obstruction is involved. Chest physiotherapy, nebulised DNase and possibly fibreoptic bronchoscopy might be helpful in patients with mucous plugging of the airways. In passive and adhesive atelectasis, positive end-expiratory pressure might be a useful adjunct to treatment. PMID:16137380
NASA Astrophysics Data System (ADS)
Asilah Khairi, Nor; Bahari Jambek, Asral
2017-11-01
An Internet of Things (IoT) device is usually powered by a small battery, which does not last long. As a result, saving energy in IoT devices has become an important issue when it comes to this subject. Since power consumption is the primary cause of radio communication, some researchers have proposed several compression algorithms with the purpose of overcoming this particular problem. Several data compression algorithms from previous reference papers are discussed in this paper. The description of the compression algorithm in the reference papers was collected and summarized in a table form. From the analysis, MAS compression algorithm was selected as a project prototype due to its high potential for meeting the project requirements. Besides that, it also produced better performance regarding energy-saving, better memory usage, and data transmission efficiency. This method is also suitable to be implemented in WSN. MAS compression algorithm will be prototyped and applied in portable electronic devices for Internet of Things applications.
Burón Martínez, E; Aguayo Maldonado, J
2006-11-01
At birth approximately 10 % of term or near-term neonates require initial stabilization maneuvers to establish a cry or regular breathing, maintain a heart rate greater than 100 beats per minute (bpm), and good color and muscular tone. About 1 % requires ventilation and very few infants receive chest compressions or medication. However, birth asphyxia is a worldwide problem and can lead to death or serious sequelae. Recently, the European Resuscitation Council (ERC) and the International Liaison Committee on Resuscitation (ILCOR) published new guidelines on resuscitation at birth. These guidelines review specific questions such as the use of air or 100 % oxygen in the delivery room, dose and routes of adrenaline delivery, the peripartum management of meconium-stained amniotic fluid, and temperature control. Assisted ventilation in preterm infants is briefly described. New devices to improve the care of newborn infants, such as the laryngeal mask airway or CO2 detectors to confirm tracheal tube placement, are also discussed. Significant changes have occurred in some practices and are included in this document.
Cardiopulmonary resuscitation using the cardio vent device in a resuscitation model.
Suner, Selim; Jay, Gregory D; Kleinman, Gary J; Woolard, Robert H; Jagminas, Liudvikas; Becker, Bruce M
2002-05-01
To compare the "Bellows on Sternum Resuscitation" (BSR) device that permits simultaneous compression and ventilation by one rescuer with two person cardiopulmonary resuscitation (CPR) with bag-valve-mask (BVM) ventilation in a single blind crossover study performed in the laboratory setting. Tidal volume and compression depth were recorded continuously during 12-min CPR sessions with the BSR device and two person CPR. Six CPR instructors performed a total of 1,894 ventilations and 10,532 compressions in 3 separate 12-min sessions. Mean tidal volume (MTV) and compression rate (CR) with the BSR device differed significantly from CPR with the BVM group (1242 mL vs. 1065 mL, respectively, p = 0.0018 and 63.2 compressions per minute (cpm) vs. 81.3 cpm, respectively, p = 0.0076). Error in compression depth (ECD) rate of 9.78% was observed with the BSR device compared to 8.49% with BMV CPR (p = 0.1815). Error rate was significantly greater during the second half of CPR sessions for both BSR and BVM groups. It is concluded that one-person CPR with the BSR device is equivalent to two-person CPR with BVM in all measured parameters except for CR. Both groups exhibited greater error rate in CPR performance in the latter half of 12-min CPR sessions.
Choa, Minhong; Cho, Junho; Choi, Young Hwan; Kim, Seungho; Sung, Ji Min; Chung, Hyun Soo
2009-06-01
The objective of this study is to compare the skill retention of two groups of lay persons, six months after their last CPR training. The intervention group was provided with animation-assisted CPRII (AA-CPRII) instruction on their cellular phones, and the control group had nothing but what they learned from their previous training. This study was a single blind randomized controlled trial. The participants' last CPR trainings were held at least six months ago. We revised our CPR animation for on-site CPR instruction content emphasizing importance of chest compression. Participants were randomized into two groups, the AA-CPRII group (n=42) and the control group (n=38). Both groups performed three cycles of CPR and their performances were video recorded. These video clips were assessed by three evaluators using a checklist. The psychomotor skills were evaluated using the ResusciAnne SkillReporter. Using the 30-point scoring checklist, the AA-CPRII group had a significantly better score compared to the control group (p<0.001). Psychomotor skills evaluated with the AA-CPRII group demonstrated better performance in hand positioning (p=0.025), compression depth (p=0.035) and compression rate (p<0.001) than the control group. The AA-CPRII group resulted in better checklist scores, including chest compression rate, depth and hand positioning. Animation-assisted CPR could be used as a reminder tool in achieving effective one-person-CPR performance. By installing the CPR instruction on cellular phones and having taught them CPR with it during the training enabled participants to perform better CPR.
[Factors affecting the survival of transplants from donors after prehospital cardiac death].
Mateos Rodríguez, Alonso Antonio; Andrés Belmonte, Amado; Del Río Gallegos, Francisco; Coll, Elisabeth
2017-06-01
To evaluate factors that influence the survival of transplanted organs from donors after prehospital cardiac death. Retrospective observational study of data collected from hospital emergency service records. Information included prehospital cardiac deaths evaluated as donors as well as patients who received transplants. Two hundred cases from 2008 through 2011 were studied. Sixty-nine potential donors (34.5%) were rejected. Three hundred organs were extracted from the remaining 131 donor cases, to yield a mean (SD) of 2.32 (0.83) transplanted organs/donor or 1.52 (1.29) organs/potential donor. One hundred fifty-two potential donors (76%) were treated with mechanical cardiopumps during transport. We detected no significant differences between cases transported with manual chest compressions and cases treated with cardiopumps regarding age (40.1 vs 43.5 years, P=.06), responder arrival times (13 min 54 s vs 12 min 54 s, P=.45), or transport times (1 h 27 min vs 1 h 32 min). However, case transported with manual chest compressions yielded significantly more kidneys (mean, 1.96/potential donor) than those transported with cardiopump compressions (mean, 1.38/potential donor) (P=.008). Eleven of the 229 kidneys harvested (4%) were not transplanted. The median (interquartile range) serum creatinine concentrations after kidney transplants at 6 and 12 months, respectively, were 1.37 (1.10-1.58) mg/dL and 1.43 (1.11-1.80) mg/dL. Our findings suggest that the use of a cardiopump reduces donor recruitment. Long-term creatinine levels are similar after transplantation of kidneys from donors transported with a cardiopump or with manual compressions.
Beachler, Jason A; Krueger, Chad A; Johnson, Anthony E
This process improvement study sought to evaluate the compliance in orthopaedic patients with sequential compression devices and to monitor any improvement in compliance following an educational intervention. All non-intensive care unit orthopaedic primary patients were evaluated at random times and their compliance with sequential compression devices was monitored and recorded. Following a 2-week period of data collection, an educational flyer was displayed in every patient's room and nursing staff held an in-service training event focusing on the importance of sequential compression device use in the surgical patient. Patients were then monitored, again at random, and compliance was recorded. With the addition of a simple flyer and a single in-service on the importance of mechanical compression in the surgical patient, a significant improvement in compliance was documented at the authors' institution from 28% to 59% (p < .0001).
Colwell, Clifford W
2014-11-01
Venous thromboembolic (VTE) events, either deep vein thromboses (DVT) or pulmonary emboli (PE), are important complications in patients undergoing knee or hip arthroplasty. Symptomatic VTE rates observed in total joint arthroplasty patients using the mobile compression device with home use capability were non-inferior to rates reported for pharmacological prophylaxis, including warfarin, enoxaparin, rivaroxaban, and dabigatran. Major bleeding in total hip arthroplasty was less using the mobile compression device than using low molecular weight heparin. A cost analysis demonstrated a cost savings based on decreased major bleeding. Use of a mobile compression device with or without aspirin for patients undergoing total joint arthroplasty provides a non-inferior risk for developing VTE compared with current pharmacological protocols.
Trapezius placement of implanted ports: understanding the procedure.
Hill, Steve
Totally implantable vascular access devices (TIVADs) are indicated for intermittent long-term intravenous access. It is widely accepted within medical literature that TIVADs are associated with statistically significant lower infection rates than other central venous access devices. Typical sites for implantation are on the anterior chest wall, using the internal jugular, axillary, cephalic or a subclavian vein. This article follows on from a previous discussion of the benefits of this approach, which illustrated and examined clinical outcomes of trapezius-placement versus anterior chest wall placed ports, for patients with metastatic subcutaneous disease on the anterior chest wall. The procedure provides a unique challenge for the clinician. This article focuses on the process of trapezius port implantation, providing an illustrative guide to understand the procedure. Trapezius port placement is a viable option for patients for whom routine sites are excluded and who require long-term intermittent vascular access.
Decreasing radiation exposure on pediatric portable chest radiographs.
Hawking, Nancy G; Sharp, Ted D
2013-01-01
To determine whether additional shielding designed for pediatric patients during portable chest exams that ascertain endotracheal tube placement would significantly decrease the amount of scatter radiation. Children aged 24 months or younger were intubated and received daily morning chest radiographs to determine endotracheal tube placement. For each measurement, the amount of scatter radiation decreased by more than 20% from a nonshielded exposure to a shielded exposure. There was a significant decrease in scatter radiation when using the lead shielding device along with appropriate collimation vs appropriate collimation alone. These results suggest that applying additional shielding to appropriately collimated chest radiographs could significantly reduce scatter radiation and therefore the overall dose to young children.
Thermal effects of dorsal head immersion in cold water on nonshivering humans.
Giesbrecht, Gordon G; Lockhart, Tamara L; Bristow, Gerald K; Steinman, Allan M
2005-11-01
Personal floatation devices maintain either a semirecumbent flotation posture with the head and upper chest out of the water or a horizontal flotation posture with the dorsal head and whole body immersed. The contribution of dorsal head and upper chest immersion to core cooling in cold water was isolated when the confounding effect of shivering heat production was inhibited with meperidine (Demerol, 2.5 mg/kg). Six male volunteers were immersed four times for up to 60 min, or until esophageal temperature = 34 degrees C. An insulated hoodless dry suit or two different personal floatation devices were used to create four conditions: 1) body insulated, head out; 2) body insulated, dorsal head immersed; 3) body exposed, head (and upper chest) out; and 4) body exposed, dorsal head (and upper chest) immersed. When the body was insulated, dorsal head immersion did not affect core cooling rate (1.1 degrees C/h) compared with head-out conditions (0.7 degrees C/h). When the body was exposed, however, the rate of core cooling increased by 40% from 3.6 degrees C/h with the head out to 5.0 degrees C/h with the dorsal head and upper chest immersed (P < 0.01). Heat loss from the dorsal head and upper chest was approximately proportional to the extra surface area that was immersed (approximately 10%). The exaggerated core cooling during dorsal head immersion (40% increase) may result from the extra heat loss affecting a smaller thermal core due to intense thermal stimulation of the body and head and resultant peripheral vasoconstriction. Dorsal head and upper chest immersion in cold water increases the rate of core cooling and decreases potential survival time.
Bavry, Anthony A; Raymond, Russell E; Bhatt, Deepak L; Chambers, Charles E; DeNardo, Andrew J; Hermiller, James B; Myers, Paul R; Pitts, Douglas E; Scott, John A; Savader, Scott J; Steinhubl, Steven
2008-04-01
The aim of vascular closure devices is to safely secure the arterial access site at the conclusion of catheterization procedures, thereby increasing patient comfort and decreasing time to hemostasis and ambulation. The FISH (femoral introducer sheath and hemostasis) device is novel in that the access sheath and closure component are incorporated onto the same system. The FISH pivotal investigation was conducted at 8 catheterization laboratories throughout the United States. Eligible diagnostic patients were randomized (2 to 1) to the FISH device versus manual compression and assessed for time to hemostasis and time to ambulation. Half of the participants underwent ultrasonographic evaluation at 30-day follow up. Enrollment for an interventional cohort is ongoing and will be reported at a later date; however, the interventional patients enrolled to date were combined with the diagnostic patients to comprise the safety data of the trial. Overall, 191 patients were randomized to the FISH device and 106 patients to manual compression. Most patients received a 6 Fr sheath (approximately 70%), while the remaining patients received a 5 or 8 Fr sheath. Twenty-seven patients who received the FISH device were converted to manual compression due to anticipated suboptimal hemostasis. Among the diagnostic patients, the mean time to hemostasis was 8.9 minutes for the FISH device, compared to 17.2 minutes for manual compression (p < 0.0001). Similarly, the mean time to ambulation was 2.4 hours for the FISH device, compared to 4.3 hours for manual compression (p < 0.0001). Among the total cohort, there was 1 death and 1 episode of major access-site-related bleeding that required transfusion occurred in the FISH group (1.1%), compared to no serious adverse safety events in the manual compression group (p = 1.0). For the FISH group, there were 5 minor adverse safety events; 3 access-site hematomas and 2 pseudoaneurysms treated with thrombin injection, and in the manual compression group, there was 2 access-site hematomas and 1 pseudoaneurysm treated with thrombin injection (p = 1.0). Among diagnostic patients with good sheath placement and favorable femoral anatomy, the FISH device is superior in achieving time to hemostasis and ambulation compared to manual compression. At 30 days, there is no apparent difference in serious or minor adverse vascular events with the use of the FISH device.
Kaul, Anand; Abbas, Ahmed; Smith, Gabriel; Manjila, Sunil; Pace, Jonathan; Steinmetz, Michael
2016-12-01
Fatal craniovertebral junction (CVJ) injuries were the most common cause of death in high-speed motor sports prior to 2001. Following the death of a mutual friend and race car driver, Patrick Jacquemart (1946-1981), biomechanical engineer Dr. Robert Hubbard, along with race car driver and brother-in-law Jim Downing, developed the concept for the Head and Neck Support (HANS) device to prevent flexion-distraction injuries during high-velocity impact. Biomechanical testing showed that neck shear and loading forces experienced during collisions were 3 times the required amount for a catastrophic injury. Crash sled testing with and without the HANS device elucidated reductions in neck tension, neck compression, head acceleration, and chest acceleration experienced by dummies during high-energy crashes. Simultaneously, motor sports accidents such as Dale Earnhardt Sr.'s fatal crash in 2001 galvanized public opinion in favor of serious safety reform. Analysis of Earnhardt's accident demonstrated that his car's velocity parallel to the barrier was more than 150 miles per hour (mph), with deceleration upon impact of roughly 43 mph in a total of 0.08 seconds. After careful review, several major racing series such as the National Association for Stock Car Auto Racing (NASCAR) and Championship Auto Racing Team (CART) made major changes to ensure the safety of drivers at the turn of the 21st century. Since the rule requiring the HANS device in professional auto racing series was put in place, there has not been a single reported case of a fatal CVJ injury.
21 CFR 868.1930 - Stethoscope head.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stethoscope head. 868.1930 Section 868.1930 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1930 Stethoscope head. (a) Identification. A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and...
Imaging the cardiac blood flow during CPR with EBCT in an animal model
NASA Astrophysics Data System (ADS)
Recheis, Wolfgang A.; Schuster, Antonius H.; Pallwein-Prettner, Leo; Kleinsasser, Axel; Loeckinger, Alexander; Hoermann, Christoph; zur Nedden, Dieter
2002-04-01
There are open questions concerning the hemodynamics during cardiopulmonary resuscitation (CPR). The purpose was to evaluate a model of the blood flow during CPR in specified anatomic regions. After cardiac arrest, one intubated swine under full intensive care supervision was scanned during CPR using an automated resuscitation device. CT scans were performed with an EBCT in the 50ms modus at eight levels, therefore covering most of the heart and pulmonary vessels. 50ml contrast agent was administered with 10ml/sec and a delay of five seconds to visualize the contrast agent passage through the heart and pulmonary circulation. The gray-value changes in previously specified ROIs were directly correlated with the resuscitation device position in respect to the thorax. The effects of CPR on the blood flow could be visualized dynamically by quantifying the contrast enhancement. The increase of gray values could be estimated with different delays, depending on the anatomical situation. The inflow and outflow dependent on thumper dynamics could be estimated. At the onset of contrast medium inflow, turbulence could be visualized in the right ventricle, which are caused by the inhomogeneous contrast medium distribution. Triggered EBCT during CPR offers the opportunity to study regional blood flow depending on chest compression.
Lopez, Manuel; Patoir, Arnaud; Varlet, François; Perez-Etchepare, Eduardo; Tiffet, Théophile; Villard, Aurelien; Tiffet, Olivier
2013-11-01
This preliminary study evaluates, by qualitative score, the efficacy of the dynamic compression system (DCS) with a pressure-measuring device in the treatment of pectus carinatum (PC) as an alternative to surgery. A total of 68 patients (infants, adolescents and young adults) presenting with typical PC (64 males and 4 females) were evaluated in our Chest Wall Deformities Unit, between October 2011 and February 2013. The criteria for including subjects were: patients with typical condrogladiolar PC and pressure for initial correction (PIC) ≤ 9 PSI (pound square inch). Seven patients were excluded in this study: three typical PC were treated by minimal invasive surgery (Abramson technique) due to highly elevated PIC and four atypical PC, hybrids forms (PE and PC) were treated by cup suction for pectus excavatum and by the DCS for the PC. The management protocol included: adjustment of the DCS, strengthening exercises and monthly clinical follow-up. The partial and final results were evaluated by the patients, by their parents or by both, using a qualitative scoring scale that was measured in a three-step grading system, where C is a low or very low result, B is acceptable and A is a very good or excellent result. A total of 61 patients (59 males and 2 females) presenting with typical PC were treated by the DCS and included: symmetric PC in 43 cases and asymmetric PC in 18 cases. The mean age was 13.5 years (5-25). The mean PIC was 6.3 PSI (3-9 PSI). The mean utilization time was 19 h daily. The patients were divided into three groups. In Group I, consisting of 35 cases, all the patients have already completed the treatment with excellent aesthetic results (A). In 12 cases, Group II, the normal shape of the thorax has been obtained; all the patients in this group rated their results as excellent (A); however, these patients are still wearing the brace as a retainer for 3 additional months. Fourteen patients, Group III, are progressing and improving under active treatment, and surgeons and patients are very satisfied with the initial results. None of the 61 patients in this study abandoned the treatment and no complications were found. This preliminary study demonstrated that the DCS with a pressure-measuring device is a minimal invasive system effective for treatment of PC in patients where the anterior chest wall is still compliant. The control of different pressure measurements could be used as the inclusion criterion as well as a predictive factor for aesthetic results and treatment duration.
2016-09-15
WHASC – Animal Final Report 18May16 1. Protocol Number: FWH200140094A 2. Type of Research: Animal Research 3. Title...6. Results: ROSC increased among standard CC animals with REBOA (33%) compared to standard CC animals without REBOA (0.0%) (p=0.04). Among...standard CC animals , aortic systolic blood pressure, right atrial systolic blood pressure and end tidal CO2 (ETCO2) increased during all time intervals of
Traumatic asphyxia: An autopsy case.
Türkmen, Nursel; Eren, Bülent; Erkol, Zerrin
2015-01-01
Traumatic asphyxia is a form of asphyxia where respiration is prevented by external pressure on the body. A 19-year-old man was found by relatives compressed by motorboat in the garage. The death was investigated by the prosecutor; body was taken to the Morgue Department for performing autopsy. On gross physical examination; the face, neck and upper part of the chest were congested and many petechiae were observed on the conjunctivae, but not in low extremities. Autopsy macroscopic examination of lungs revealed congestion, sub pleural superficial bleeding areas. In the presented case death was reported as traumatic asphyxia by thorax compression without other lethal factors.
The cardiocerebral resuscitation protocol for treatment of out-of-hospital primary cardiac arrest.
Ewy, Gordon A
2012-09-15
Out-of-hospital cardiac arrest (OHCA) is a significant public health problem in most westernized industrialized nations. In spite of national and international guidelines for cardiopulmonary resuscitation and emergency cardiac care, the overall survival of patients with OHCA was essentially unchanged for 30 years--from 1978 to 2008 at 7.6%. Perhaps a better indicator of Emergency Medical System (EMS) effectiveness in treating patients with OHCA is to focus on the subgroup that has a reasonable chance of survival, e.g., patients found to be in ventricular fibrillation (VF). But even in this subgroup, the average survival rate was 17.7% in the United States, unchanged between 1980 and 2003, and 21% in Europe, unchanged between 1980 and 2004. Prior to 2003, the survival of patients with OHCA, in VF in Tucson, Arizona was less than 9% in spite of incorporating previous guideline recommendations. An alternative (non-guidelines) approach to the therapy of patients with OHCA and a shockable rhythm, called Cardiocerebral Resuscitation, based on our extensive physiologic laboratory studies, was introduced in Tucson in 2003, in rural Wisconsin in 2004, and in selected EMS areas in the metropolitan Phoenix area in 2005. Survival of patients with OHCA due to VF treated with Cardiocerebral Resuscitation in rural Wisconsin increased to 38% and in 60 EMS systems in Arizona to 39%. In 2004, we began a statewide program to advocate chest compression-only CPR for bystanders of witnessed primary OHCA. Over the next five years, we found that survival of patients with a shockable rhythm was 17.7% in those treated with standard bystander CPR (mouth-to-mouth ventilations plus chest compression) compared to 33.7% for those who received bystander chest-compression-only CPR. This article on Cardiocerebral Resuscitation, by invitation following a presentation at the 2011 Danish Society Emergency Medical Conference, summarizes the results of therapy of patients with primary OHCA treated with Cardiocerebral Resuscitation, with requested emphasis on the EMS protocol.
The Cardiocerebral Resuscitation protocol for treatment of out-of-hospital primary cardiac arrest
2012-01-01
Out-of-hospital cardiac arrest (OHCA) is a significant public health problem in most westernized industrialized nations. In spite of national and international guidelines for cardiopulmonary resuscitation and emergency cardiac care, the overall survival of patients with OHCA was essentially unchanged for 30 years--from 1978 to 2008 at 7.6%. Perhaps a better indicator of Emergency Medical System (EMS) effectiveness in treating patients with OHCA is to focus on the subgroup that has a reasonable chance of survival, e.g., patients found to be in ventricular fibrillation (VF). But even in this subgroup, the average survival rate was 17.7% in the United States, unchanged between 1980 and 2003, and 21% in Europe, unchanged between 1980 and 2004. Prior to 2003, the survival of patients with OHCA, in VF in Tucson, Arizona was less than 9% in spite of incorporating previous guideline recommendations. An alternative (non-guidelines) approach to the therapy of patients with OHCA and a shockable rhythm, called Cardiocerebral Resuscitation, based on our extensive physiologic laboratory studies, was introduced in Tucson in 2003, in rural Wisconsin in 2004, and in selected EMS areas in the metropolitan Phoenix area in 2005. Survival of patients with OHCA due to VF treated with Cardiocerebral Resuscitation in rural Wisconsin increased to 38% and in 60 EMS systems in Arizona to 39%. In 2004, we began a statewide program to advocate chest compression-only CPR for bystanders of witnessed primary OHCA. Over the next five years, we found that survival of patients with a shockable rhythm was 17.7% in those treated with standard bystander CPR (mouth-to-mouth ventilations plus chest compression) compared to 33.7% for those who received bystander chest-compression-only CPR. This article on Cardiocerebral Resuscitation, by invitation following a presentation at the 2011 Danish Society Emergency Medical Conference, summarizes the results of therapy of patients with primary OHCA treated with Cardiocerebral Resuscitation, with requested emphasis on the EMS protocol. PMID:22980487
Nii, Kouhei; Nakai, Kanji; Tsutsumi, Masanori; Aikawa, Hiroshi; Iko, Minoru; Sakamoto, Kimiya; Mitsutake, Takafumi; Eto, Ayumu; Hanada, Hayatsura; Kazekawa, Kiyoshi
2015-01-01
We investigated the incidence of embolic protection device retrieval difficulties at carotid artery stenting (CAS) with a closed-cell stent and demonstrated the usefulness of a manual carotid compression assist technique. Between July 2010 and October 2013, we performed 156 CAS procedures using self-expandable closed-cell stents. All procedures were performed with the aid of a filter design embolic protection device. We used FilterWire EZ in 118 procedures and SpiderFX in 38 procedures. The embolic protection device was usually retrieved by the accessory retrieval sheath after CAS. We applied a manual carotid compression technique when it was difficult to navigate the retrieval sheath through the deployed stent. We compared clinical outcomes in patients where simple retrieval was possible with patients where the manual carotid compression assisted technique was used for retrieval. Among the 156 CAS procedures, we encountered 12 (7.7%) where embolic protection device retrieval was hampered at the proximal stent terminus. Our manual carotid compression technique overcame this difficulty without eliciting neurologic events, artery dissection, or stent deformity. In patients undergoing closed-cell stent placement, embolic protection device retrieval difficulties may be encountered at the proximal stent terminus. Manual carotid compression assisted retrieval is an easy, readily available solution to overcome these difficulties. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Mier, José M; Molins, Laureano; Fibla, Juan J
2010-06-01
Persistent air leaks represent the most common pulmonary complication after elective lung resection. Since there are insufficient data in the literature regarding variability in the withdrawal of postoperative pleural drainages, we have designed a prospective, consecutive and comparative study to evaluate if the use of digital devices (Thopaz and DigiVent) to measure postoperative air leak compared to a Pleur-Evac varies on deciding when to withdraw chest tubes after lung resection. A prospective, consecutive and comparative trial was conducted in 75 patients who underwent elective pulmonary resection for non small cell lung cancer. This study compared two digitals devices with the current analogue version in 75 patients. The digital and analogue groups had 26, 24, and 25 patients, respectively. Clinical population data were not statistically different between the groups. The withdrawal of the chest tube was Thopaz, 2.4 days; Digivent, 3.3 days and PleurEvac, 4.5 days. Patients and nurses were subjectively more comfortable with digital devices. Surgeons obtained more objective information with digital devices. The safety mechanism of the Thopaz was also subjectively better, and one patient was discharged home without complications after one week. The digital and continuous measurement of air leak instead of the currently used static analogue systems reduced the chest tube withdrawal and hospital stay by more accurately and reproducibly measuring air leak. Intrapleural pressure curves from the Digivent may also help predict the optimal chest tube setting for each patient. The Thopaz alarm mechanism is very useful to prevent deficiencies in the mechanism and do not required wall suction. Copyright (c) 2010 AEC. Published by Elsevier Espana. All rights reserved.
Wave energy devices with compressible volumes.
Kurniawan, Adi; Greaves, Deborah; Chaplin, John
2014-12-08
We present an analysis of wave energy devices with air-filled compressible submerged volumes, where variability of volume is achieved by means of a horizontal surface free to move up and down relative to the body. An analysis of bodies without power take-off (PTO) systems is first presented to demonstrate the positive effects a compressible volume could have on the body response. Subsequently, two compressible device variations are analysed. In the first variation, the compressible volume is connected to a fixed volume via an air turbine for PTO. In the second variation, a water column separates the compressible volume from another volume, which is fitted with an air turbine open to the atmosphere. Both floating and bottom-fixed, axisymmetric, configurations are considered, and linear analysis is employed throughout. Advantages and disadvantages of each device are examined in detail. Some configurations with displaced volumes less than 2000 m 3 and with constant turbine coefficients are shown to be capable of achieving 80% of the theoretical maximum absorbed power over a wave period range of about 4 s.
Wave energy devices with compressible volumes
Kurniawan, Adi; Greaves, Deborah; Chaplin, John
2014-01-01
We present an analysis of wave energy devices with air-filled compressible submerged volumes, where variability of volume is achieved by means of a horizontal surface free to move up and down relative to the body. An analysis of bodies without power take-off (PTO) systems is first presented to demonstrate the positive effects a compressible volume could have on the body response. Subsequently, two compressible device variations are analysed. In the first variation, the compressible volume is connected to a fixed volume via an air turbine for PTO. In the second variation, a water column separates the compressible volume from another volume, which is fitted with an air turbine open to the atmosphere. Both floating and bottom-fixed, axisymmetric, configurations are considered, and linear analysis is employed throughout. Advantages and disadvantages of each device are examined in detail. Some configurations with displaced volumes less than 2000 m3 and with constant turbine coefficients are shown to be capable of achieving 80% of the theoretical maximum absorbed power over a wave period range of about 4 s. PMID:25484609
Radiation dermatitis caused by a bolus effect from an abdominal compression device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Connor, Michael; Wei, Randy L.; Yu, Suhong
American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up betweenmore » the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special consideration must be given to contour and/or avoiding beam entrance to the device, and to the use of such devices in patients who may have heightened radiosensitivity, such as those who are human immunodeficiency virus (HIV)–positive.« less
2011-01-01
Background During circulatory arrest, effective external chest compression (ECC) is a key element for patient survival. In 2005, international emergency medical organisations changed their recommended compression-ventilation ratio (CVR) from 15:2 to 30:2 to acknowledge the vital importance of ECC. We hypothesised that physical fitness, biometric data and gender can influence the quality of ECC. Furthermore, we aimed to determine objective parameters of physical fitness that can reliably predict the quality of ECC. Methods The physical fitness of 30 male and 10 female healthcare professionals was assessed by cycling and rowing ergometry (focussing on lower and upper body, respectively). During ergometry, continuous breath-by-breath ergospirometric measurements and heart rate (HR) were recorded. All participants performed two nine-minute sequences of ECC on a manikin using CVRs of 30:2 and 15:2. We measured the compression and decompression depths, compression rates and assessed the participants' perception of exhaustion and comfort. The median body mass index (BMI; male 25.4 kg/m2 and female 20.4 kg/m2) was used as the threshold for subgroup analyses of participants with higher and lower BMI. Results HR during rowing ergometry at 75 watts (HR75) correlated best with the quality of ECC (r = -0.57, p < 0.05). Participants with a higher BMI and better physical fitness performed better and showed less fatigue during ECC. These results are valid for the entire cohort, as well as for the gender-based subgroups. The compressions of female participants were too shallow and more rapid (mean compression depth was 32 mm and rate was 117/min with a CVR of 30:2). For participants with a lower BMI and higher HR75, the compression depth decreased over time, beginning after four minutes for the 15:2 CVR and after three minutes for the 30:2 CVR. Although found to be more exhausting, a CVR of 30:2 was rated as being more comfortable. Conclusion The quality of the ECC and fatigue can both be predicted by BMI and physical fitness. An evaluation focussing on the upper body may be a more valid predictor of ECC quality than cycling based tests. Our data strongly support the recommendation to relieve ECC providers after two minutes. PMID:22053981
Advantage of vein grafts for anomalous origin of a right coronary artery.
Kansaku, Rei; Saitoh, Hirofumi; Eguchi, Shoji; Maruyama, Yukio; Ohtsuka, Hideaki; Higuchi, Kotaro
2009-03-01
A 66-year-old man with anomalous origin of the right coronary artery suffered from chest pain. The results of coronary angiography and multidetector computer tomography indicated that the proximal right coronary artery was intermittently compressed, causing the ischemia. Coronary artery bypass grafting was regarded as a reliable treatment compared with percutaneous coronary intervention or other surgeries. Because of plentiful flow of the right coronary artery, we decided to use a vein graft to avoid competitive flow. Postoperative coronary angiography revealed intact flow in both the native coronary artery and the vein graft 1 year after the surgery. The myocardial ischemia seen on scintigraphy and the chest pain had disappeared.
Evaluation of Infrared Thermometry in Cynomolgus Macaques (Macaca fascicularis).
Laffins, Michael M; Mellal, Nacera; Almlie, Cynthia L; Regalia, Douglas E
2017-01-01
Recording an accurate body temperature is important to assess an animal's health status. We compared temperature data from sedated cynomolgus macaques (Macaca fascicularis) to evaluate differences between rectal, infrared (inguinal and chest), and implanted telemetry techniques with the objective of demonstrating the diagnostic equivalence of the infrared device with other approaches. Infrared thermometer readings are instantaneous and require no contact with the animal. Body temperature data were obtained from 205 (137 male, 68 female) cynomolgus macaques under ketamine (10 mg/kg IM) sedation over a 3-mo period during scheduled physical examinations. Infrared measurements were taken 5 cm from the chest and inguinal areas. We evaluated 10 (9 functional devices) sedated cynomolgus macaques (5 male, 5 female) implanted with telemetry units in a muscular pouch between the internal and external abdominal oblique muscles. We determined that the mean body temperature acquired by using telemetry did not differ from either the mean of inguinal and chest infrared measurements but did differ from the mean of temperature obtained rectally. In addition, the mean rectal temperature differed from the mean of the inguinal reading but not the mean of the chest temperature. The results confirm our hypothesis that the infrared thermometer can be used to replace standard rectal thermometry.
2015-01-01
streak tube imaging Lidar [15]. Nevertheless, instead of one- dimensional (1D) fan beam, a laser source modulates the digital micromirror device DMD and...Trans. Inform. Theory, vol. 52, pp. 1289-1306, 2006. [10] D. Dudley, W. Duncan and J. Slaughter, "Emerging Digital Micromirror Device (DMD) Applications
Panchal, Ashish R; Meziab, Omar; Stolz, Uwe; Anderson, Wes; Bartlett, Mitchell; Spaite, Daniel W; Bobrow, Bentley J; Kern, Karl B
2014-09-01
Recent studies have demonstrated higher-quality chest compressions (CCs) following a 60 s ultra-brief video (UBV) on compression-only CPR (CO-CPR). However, the effectiveness of UBVs as a CPR-teaching tool for lay bystanders in public venues remains unknown. Determine whether an UBV is effective in teaching laypersons CO-CPR in a public setting and if viewing leads to superior responsiveness and CPR skills. Adult lay bystanders were enrolled in a public shopping mall and randomized to: (1) Control (CTR): sat idle for 60 s; (2) UBV: watched a 60 s UBV on CO-CPR. Subjects were read a scenario detailing a sudden collapse in the mall and asked to do what they "thought was best" on a mannequin. Performance measures were recorded for 2 min: responsiveness (time to call 911 and first CCs) and CPR quality [CC depth, rate, hands-off interval (time without CC after first CC)]. One hundred subjects were enrolled. Demographics were similar between groups. UBV subjects called 911 more frequently (percent difference: 31%) and initiated CCs sooner in the arrest scenario (median difference (MD): 5 s). UBV cohort had increased CC rate (MD: 19 cpm) and decreased hands-off interval (MD: 27 s). There was no difference in CC depth. Bystanders with UBV training in a shopping mall had significantly improved responsiveness, CC rate, and decreased hands-off interval. Given the short length of training, UBV may have potential as a ubiquitous intervention for public venues to help improve bystander reaction to arrest and CO-CPR performance. Published by Elsevier Ireland Ltd.
Chen, Jie; Lu, Kai-Zhi; Yi, Bin; Chen, Yan
2016-04-01
Following a chemical, biological, radiation, and nuclear incident, prompt cardiopulmonary resuscitation (CPR) procedure is essential for patients who suffer cardiac arrest. But CPR when wearing personal protection equipment (PPE) before decontamination becomes a challenge for healthcare workers (HCW). Although previous studies have assessed the impact of PPE on airway management, there is little research available regarding the quality of chest compression (CC) when wearing PPE.A present randomized cross-over simulation study was designed to evaluate the effect of PPE on CC performance using mannequins.The study was set in one university medical center in the China.Forty anesthesia residents participated in this randomized cross-over study.Each participant performed 2 min of CC on a manikin with and without PPE, respectively. Participants were randomized into 2 groups that either performed CC with PPE first, followed by a trial without PPE after a 180-min rest, or vice versa.CPR recording technology was used to objectively quantify the quality of CC. Additionally, participants' physiological parameters and subjective fatigue score values were recorded.With the use of PPE, a significant decrease of the percentage of effective compressions (41.3 ± 17.1% with PPE vs 67.5 ± 15.6% without PPE, P < 0.001) and the percentage of adequate compressions (67.7 ± 18.9% with PPE vs 80.7 ± 15.5% without PPE, P < 0.001) were observed. Furthermore, the increases in heart rate, mean arterial pressure, and subjective fatigue score values were more obvious with the use of PPE (all P < 0.01).We found significant deterioration of CC performance in HCW with the use of a level-C PPE, which may be a disadvantage for enhancing survival of cardiac arrest.
Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo
2017-01-01
Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Compliant Buckled Foam Actuators and Application in Patient-Specific Direct Cardiac Compression.
Mac Murray, Benjamin C; Futran, Chaim C; Lee, Jeanne; O'Brien, Kevin W; Amiri Moghadam, Amir A; Mosadegh, Bobak; Silberstein, Meredith N; Min, James K; Shepherd, Robert F
2018-02-01
We introduce the use of buckled foam for soft pneumatic actuators. A moderate amount of residual compressive strain within elastomer foam increases the applied force ∼1.4 × or stroke ∼2 × compared with actuators without residual strain. The origin of these improved characteristics is explained analytically. These actuators are applied in a direct cardiac compression (DCC) device design, a type of implanted mechanical circulatory support that avoids direct blood contact, mitigating risks of clot formation and stroke. This article describes a first step toward a pneumatically powered, patient-specific DCC design by employing elastomer foam as the mechanism for cardiac compression. To form the device, a mold of a patient's heart was obtained by 3D printing a digitized X-ray computed tomography or magnetic resonance imaging scan into a solid model. From this model, a soft, robotic foam DCC device was molded. The DCC device is compliant and uses compressed air to inflate foam chambers that in turn apply compression to the exterior of a heart. The device is demonstrated on a porcine heart and is capable of assisting heart pumping at physiologically relevant durations (∼200 ms for systole and ∼400 ms for diastole) and stroke volumes (∼70 mL). Although further development is necessary to produce a fully implantable device, the material and processing insights presented here are essential to the implementation of a foam-based, patient-specific DCC design.
Kim, Michele M; Zhu, Timothy C
2013-02-02
During HPPH-mediated pleural photodynamic therapy (PDT), it is critical to determine the anatomic geometry of the pleural surface quickly as there may be movement during treatment resulting in changes with the cavity. We have developed a laser scanning device for this purpose, which has the potential to obtain the surface geometry in real-time. A red diode laser with a holographic template to create a pattern and a camera with auto-focusing abilities are used to scan the cavity. In conjunction with a calibration with a known surface, we can use methods of triangulation to reconstruct the surface. Using a chest phantom, we are able to obtain a 360 degree scan of the interior in under 1 minute. The chest phantom scan was compared to an existing CT scan to determine its accuracy. The laser-camera separation can be determined through the calibration with 2mm accuracy. The device is best suited for environments that are on the scale of a chest cavity (between 10cm and 40cm). This technique has the potential to produce cavity geometry in real-time during treatment. This would enable PDT treatment dosage to be determined with greater accuracy. Works are ongoing to build a miniaturized device that moves the light source and camera via a fiber-optics bundle commonly used for endoscopy with increased accuracy.
Moretti, Claudio; Quadri, Giorgio; Gaita, Fiorenzo; Sheiban, Imad
2011-01-01
Diagnostic cardiac catheterizations are predominantly performed using the femoral artery access. Several devices have been developed to aid in the closure of femoral arteriotomy. Safeguard® is a new pneumatic compression device that has been developed for compression of the femoral artery after brief manual compression. We hereby report the case of an elderly patient who underwent a percutaneous coronary intervention via the femoral artery in whom a Safeguard™ device, left overnight because of persistent oozing, provoked an extensive pressure ulcer. Knowledge of this potential complication is important to minimize its occurance and provide appropriate treatment. PMID:21977303
Moretti, Claudio; Quadri, Giorgio; Gaita, Fiorenzo; Sheiban, Imad
2011-01-01
Diagnostic cardiac catheterizations are predominantly performed using the femoral artery access. Several devices have been developed to aid in the closure of femoral arteriotomy.Safeguard® is a new pneumatic compression device that has been developed for compression of the femoral artery after brief manual compression. We hereby report the case of an elderly patient who underwent a percutaneous coronary intervention via the femoral artery in whom a Safeguard™ device, left overnight because of persistent oozing, provoked an extensive pressure ulcer. Knowledge of this potential complication is important to minimize its occurance and provide appropriate treatment.
Quasi-Isentropic Compressibility of Deuterium at a Pressure of 12 TPa
NASA Astrophysics Data System (ADS)
Mochalov, M. A.; Il'kaev, R. I.; Fortov, V. E.; Mikhailov, A. L.; Arinin, V. A.; Blikov, A. O.; Komrakov, V. A.; Maksimkin, I. P.; Ogorodnikov, V. A.; Ryzhkov, A. V.
2018-04-01
An experimental result for the quasi-isentropic compressibility of a strongly nonideal deuterium plasma compressed in a spherical device by the pressure P = 11400 GPa (114 Mbar) to the density ρ ≈ 10g/cm3 has been reported. The characteristics of the experimental device, diagnostic methods, and experimental results have been described. The trajectory of motion of metallic shells compressing a deuterium plasma has been recorded using intense pulsed sources of X rays with the boundary energy of electrons up to 60 MeV. The deuterium plasma density ρ ≈ 10g/cm3 has been determined from the measured radius of the shell at the time of its "stop." The pressure of the compressed plasma has been determined from gas-dynamic calculations taking into account the real characteristics of the experimental device.
Skillman, Joanna; Thomas, Sunil
2011-12-01
When intermittent compression devices (ICDs) are used to prevent venous thromboembolism (VTE) they can cause pressure sores in a selected group of women, undergoing long operations. A prospective audit pre and post intervention showed a reduced risk with an alternative device, without increasing the risk of VTE.
Compressive sensing scalp EEG signals: implementations and practical performance.
Abdulghani, Amir M; Casson, Alexander J; Rodriguez-Villegas, Esther
2012-11-01
Highly miniaturised, wearable computing and communication systems allow unobtrusive, convenient and long term monitoring of a range of physiological parameters. For long term operation from the physically smallest batteries, the average power consumption of a wearable device must be very low. It is well known that the overall power consumption of these devices can be reduced by the inclusion of low power consumption, real-time compression of the raw physiological data in the wearable device itself. Compressive sensing is a new paradigm for providing data compression: it has shown significant promise in fields such as MRI; and is potentially suitable for use in wearable computing systems as the compression process required in the wearable device has a low computational complexity. However, the practical performance very much depends on the characteristics of the signal being sensed. As such the utility of the technique cannot be extrapolated from one application to another. Long term electroencephalography (EEG) is a fundamental tool for the investigation of neurological disorders and is increasingly used in many non-medical applications, such as brain-computer interfaces. This article investigates in detail the practical performance of different implementations of the compressive sensing theory when applied to scalp EEG signals.
[Sleeve resection of right main bronchus for posttraumatic bronchial stenosis].
Bobocea, Andrei Cristian; Matache, Radu; Codreşi, Mihaela; Bolca, Ciprian; Cordoş, Ioan
2011-01-01
Tracheobronchial disruption is one of the most severe injuries caused by blunt chest trauma. A high index of clinical suspicion and accurate interpretation of radiological findings are necessary for prompt surgical intervention with primary repair of the airway. Delays in treatment increases the risk of partial to complete bronchial stenosis. A 21 years old male was admitted to our hospital following a workplace accident. A chest radiograph showed bilateral pneumothorax, cephalic and mediastinal emphysema. Chest tubes were placed on each side, with full pulmonary expansion and remission of emphysema. Minimal lesions of the right main bronchus were found at fiberoptic bronchoscopy. Daily chest X-rays showed an uncomplicated recovery. A stenosis was suspected due to right lung pneumonia evolving under specific antibiotherapy. Right main bronchus posttraumatic stricture was diagnosed by fiberoptic bronchoscopy. He underwent a right lateral thoracotomy with sleeve resection of stenotic bronchi. Control bronchoscopy reveals main bronchus widely patent with untraceable suture line. Main bronchus rupture in blunt chest trauma is an additive effect of chest wall compression between two solid surfaces, traction on the carina and sudden increase in intraluminal pressure. Symptoms may vary: soft air leak, pneumothorax or limited mediastinal emphysema. Bronchoscopy should be performed immediately or when available. Granulation tissue leads to progressive bronchial obstruction, with distal infection and permanent parenchymal damage. Sleeve resection of the stenosed segment is the treatment of choice and restores fully the lung function. Rupture of main bronchus is a complication of blunt chest trauma. Flexible bronchoscopy is useful and reliable for early diagnosis of traumatic tracheobronchial injuries. Delayed diagnosis can lead to lung parenchyma alteration due to retrostenotic pneumonia. Resection and end-to-end anastomosis is the key of successful in these cases.
Three-dimensional automatic computer-aided evaluation of pleural effusions on chest CT images
NASA Astrophysics Data System (ADS)
Bi, Mark; Summers, Ronald M.; Yao, Jianhua
2011-03-01
The ability to estimate the volume of pleural effusions is desirable as it can provide information about the severity of the condition and the need for thoracentesis. We present here an improved version of an automated program to measure the volume of pleural effusions using regular chest CT images. First, the lungs are segmented using region growing, mathematical morphology, and anatomical knowledge. The visceral and parietal layers of the pleura are then extracted based on anatomical landmarks, curve fitting and active contour models. The liver and compressed tissues are segmented out using thresholding. The pleural space is then fitted to a Bezier surface which is subsequently projected onto the individual two-dimensional slices. Finally, the volume of the pleural effusion is quantified. Our method was tested on 15 chest CT studies and validated against three separate manual tracings. The Dice coefficients were 0.74+/-0.07, 0.74+/-0.08, and 0.75+/-0.07 respectively, comparable to the variation between two different manual tracings.
Drummond, David; Arnaud, Cécile; Guedj, Romain; Duguet, Alexandre; de Suremain, Nathalie; Petit, Arnaud
2017-02-01
To determine whether real-time video communication between the first responder and a remote intensivist via Google Glass improves the management of a simulated in-hospital pediatric cardiopulmonary arrest before the arrival of the ICU team. Randomized controlled study. Children's hospital at a tertiary care academic medical center. Forty-two first-year pediatric residents. Pediatric residents were evaluated during two consecutive simulated pediatric cardiopulmonary arrests with a high-fidelity manikin. During the second evaluation, the residents in the Google Glass group were allowed to seek help from a remote intensivist at any time by activating real-time video communication. The residents in the control group were asked to provide usual care. The main outcome measures were the proportion of time for which the manikin received no ventilation (no-blow fraction) or no compression (no-flow fraction). In the first evaluation, overall no-blow and no-flow fractions were 74% and 95%, respectively. During the second evaluation, no-blow and no-flow fractions were similar between the two groups. Insufflations were more effective (p = 0.04), and the technique (p = 0.02) and rate (p < 0.001) of chest compression were more appropriate in the Google Glass group than in the control group. Real-time video communication between the first responder and a remote intensivist through Google Glass did not decrease no-blow and no-flow fractions during the first 5 minutes of a simulated pediatric cardiopulmonary arrest but improved the quality of the insufflations and chest compressions provided.
The primacy of basics in advanced life support.
Chamberlain, Douglas; Frenneaux, Michael; Fletcher, David
2009-06-01
The standards required for optimal effect of chest compressions and the degree to which most practice falls short of ideal have not been widely appreciated. This review highlights some of the important data now available and offers a haemodynamic explanation that broadens current concepts. New techniques have permitted a detailed examination of how compressions are performed in practice. The implications of recent experimental work adds a new imperative to the need for improvement. In addition to highlighting the need for improved training and audit, the greater understanding of mechanisms in resuscitation suggest that guidelines for management of adult cardiac arrest of presumed cardiac origin need further revision and simplification.
High-speed reconstruction of compressed images
NASA Astrophysics Data System (ADS)
Cox, Jerome R., Jr.; Moore, Stephen M.
1990-07-01
A compression scheme is described that allows high-definition radiological images with greater than 8-bit intensity resolution to be represented by 8-bit pixels. Reconstruction of the images with their original intensity resolution can be carried out by means of a pipeline architecture suitable for compact, high-speed implementation. A reconstruction system is described that can be fabricated according to this approach and placed between an 8-bit display buffer and the display's video system thereby allowing contrast control of images at video rates. Results for 50 CR chest images are described showing that error-free reconstruction of the original 10-bit CR images can be achieved.
All-tantalum electrolytic capacitor
NASA Technical Reports Server (NTRS)
Green, G. E., Jr.
1977-01-01
Device uses single-compression tantalum-to-tantalum seal. Single-compression seal allows better utilization of volume within device. As result of all-tantalum case and lengthened cathode, electrical parameters, particularly equivalent series resistance and capacitance stability, improved over silver-cased capacitor.
High frequency chest wall compression and carbon dioxide elimination in obstructed dogs.
Gross, D; Vartian, V; Minami, H; Chang, H K; Zidulka, A
1984-01-01
High frequency chest wall compression (HFCWC) was studied as a method of assisting ventilation in six spontaneously breathing anesthetized dogs. Under a constant level of anesthesia, the dogs became hypercapneic after airflow obstruction was created by metal beads inserted in the airways. HFCWC was achieved by a piston pump rapidly oscillating the pressure in a modified double blood pressure cuff wrapped around the lower thorax. Thirty minute periods of spontaneous ventilation were alternated with thirty minute periods of spontaneous breathing plus HFCWC at 3, 5 or 8 Hz. The superimposition of HFCWC to spontaneous ventilation resulted in little change in the PaO2. The PaCO2, however, was reduced in every case from a mean of 6.55 +/- 0.59 to 4.72 +/- 0.32 kPa at 3 Hz (p less than 0.05), 6.92 +/- 0.57 to 3.9 +/- 0.45 kPa at 5 Hz (p less than 0.01) and 7.10 +/- 0.65 to 4.56 +/- 0.59 kPa at 8 Hz (p less than 0.05). This occurred despite a decrease in spontaneous minute ventilation. We conclude that HFCWC can assist in elimination of CO2 in obstructed spontaneous breathing dogs with hypercapnea.
Garg, Rakesh; Ahmed, Syed Moied; Kapoor, Mukul Chandra; Rao, SSC Chakra; Mishra, Bibhuti Bhusan; Kalandoor, M Venkatagiri; Singh, Baljit; Divatia, Jigeeshu Vasishtha
2017-01-01
The cardiopulmonary resuscitation (CPR) guideline of comprehensive cardiopulmonary life support (CCLS) for management of the patient with cardiopulmonary arrest in adults provides an algorithmic step-wise approach for optimal outcome of the patient inside the hospital by trained medics and paramedics. This guideline has been developed considering the infrastructure of healthcare delivery system in India. This is based on evidence in the international and national literature. In the absence of data from the Indian population, the extrapolation has been made from international data, discussed with Indian experts and modified accordingly to ensure their applicability in India. The CCLS guideline emphasise the need to recognise patients at risk for cardiac arrest and their timely management before a cardiac arrest occurs. The basic components of CPR include chest compressions for blood circulation; airway maintenance to ensure airway patency; lung ventilation to enable oxygenation and defibrillation to convert a pathologic ‘shockable’ cardiac rhythm to one capable to maintaining effective blood circulation. CCLS emphasises incorporation of airway management, drugs, and identification of the cause of arrest and its correction, while chest compression and ventilation are ongoing. It also emphasises the value of organised team approach and optimal post-resuscitation care. PMID:29217853
Kim, Tae-Hoon; Heo, Dong-Woon; Jeong, Chang-Won; Ryu, Jong-Hyun; Jun, Hong Young; Han, Seung-Jun; Ha, Taeuk; Yoon, Kwon-Ha
2017-01-01
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines. PMID:28272336
Kim, Tae-Hoon; Heo, Dong-Woon; Jeong, Chang-Won; Ryu, Jong-Hyun; Jun, Hong Young; Han, Seung-Jun; Ha, Taeuk; Yoon, Kwon-Ha
2017-03-07
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles ( p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.
Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain
2017-08-01
Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Ibrahim, Mona; Ahmed, Azza; Mohamed, Warda Yousef; El-Sayed Abu Abduo, Somaya
2015-01-01
Trauma is the leading cause of death in Americans up to 44 years old each year. Deep vein thrombosis (DVT) is a significant condition occurring in trauma, and prophylaxis is essential to the appropriate management of trauma patients. The incidence of DVT varies in trauma patients, depending on patients' risk factors, modality of prophylaxis, and methods of detection. However, compression devices and arteriovenous (A-V) foot pumps prophylaxis are recommended in trauma patients, but the efficacy and optimal use of it is not well documented in the literature. The aim of this study was to review the literature on the effect of compression devices in preventing DVT among adult trauma patients. We searched through PubMed, CINAHL, and Cochrane Central Register of Controlled Trials for eligible studies published from 1990 until June 2014. Reviewers identified all randomized controlled trials that satisfied the study criteria, and the quality of included studies was assessed by Cochrane risk of bias tool. Five randomized controlled trials were included with a total of 1072 patients. Sequential compression devices significantly reduced the incidence of DVT in trauma patients. Also, foot pumps were more effective in reducing incidence of DVT compared with sequential compression devices. Sequential compression devices and foot pumps reduced the incidence of DVT in trauma patients. However, the evidence is limited to a small sample size and did not take into account other confounding variables that may affect the incidence of DVT in trauma patients. Future randomized controlled trials with larger probability samples to investigate the optimal use of mechanical prophylaxis in trauma patients are needed.
Abcejo, Arnoley S; Diaz Soto, Juan; Castoro, Courtney; Armour, Sarah; Long, Timothy R
2017-08-01
In a healthy 12-year-old female with scoliosis, prone positioning resulted in pressor-refractory cardiovascular collapse. Resumption of supine position immediately improved hemodynamics. Intraoperative transesophageal echocardiography (TEE) revealed a collapsed left atrium and biventricular failure. Repeat prone positioning resulted in a recurrence of hypotension. However, hemodynamic stabilization was restored and maintained by repositioning chest pads caudally. The patient successfully underwent a 6-hour scoliosis repair without perioperative morbidity. With this case, we aim to: (1) reintroduce awareness of this mechanical obstructive cause of reversible hypotension; (2) highlight the use of intraoperative TEE during prone hemodynamic collapse; and (3) suggest an alternative prone positioning technique if chest compression results in hemodynamic instability.
Use of ultraportable vacuum therapy systems in the treatment of venous leg ulcer.
Cuomo, Roberto; Nisi, Giuseppe; Grimaldi, Luca; Brandi, Cesare; D'Aniello, Carlo
2017-10-23
The high incidence of venous leg ulcers and the difficult to give a complete healing involves in an increase of costs for National Health System. Main therapies to obtain a fast healing are compressive bandages, treatment of abnormal venous flow and in-situ-strategies of wound care. Negative pressure therapy does not conventionally used, because these systems not allow the use of compression bandages. Recently the development of ultraportable devices has improved the compliance and the results. Ten patients with venous chronic ulcer on the lower extremities were recruited for this study: all patients had venous leg ulcers from at least one year. We treated the patients with autologous partial thickness skin graft and subsequently we applied NANOVA device included in compressive bandage. We used NANOVA for fourteen days and after we made traditional medications. We submitted a questionnaire to evaluate the impact of dressing and NANOVA device in the quality of life of patients. The device contributed to the formation of granulation tissue and increased the success rate of autologous skin graft without limiting mobility of patient. In addition to this, we have been able to perform compression bandages thanks to small size of this device. Eight ulcers healed within 90 days of medication. We believe that ultraportable negative pressure systems are useful devices for treatment of venous leg ulcers because them allows to realize a compressive bandage without mobility limitations.
Oscillating devices for airway clearance in people with cystic fibrosis.
Morrison, Lisa; Agnew, Jennifer
2014-07-20
Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis. Oscillating devices generate intra- or extra-thoracic oscillations orally or external to the chest wall. Internally they create variable resistances within the airways, generating controlled oscillating positive pressure which mobilises mucus. Extra-thoracic oscillations are generated by forces outside the respiratory system, e.g. high frequency chest wall oscillation. To identify whether oscillatory devices, oral or chest wall, are effective for mucociliary clearance and whether they are equivalent or superior to other forms of airway clearance in the successful management of secretions in people with cystic fibrosis. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches and hand searches of relevant journals and abstract books of conference proceedings. Latest search of the Cystic Fibrosis Trials Register: 13 January 2014. Randomised controlled studies and controlled clinical studies of oscillating devices compared with any other form of physiotherapy in people with cystic fibrosis. Single-treatment interventions (therapy technique used only once in the comparison) were excluded. Two authors independently applied the inclusion criteria to publications and assessed the quality of the included studies. The searches identified 68 studies with a total of 288 references; 35 studies (total of 1050 participants) met the inclusion criteria. Studies varied in duration from up to one week to one year; 20 of the studies were cross-over in design. The studies also varied in type of intervention and the outcomes measured, furthermore data were not published in sufficient detail in most of these studies, so meta-analysis was limited. Few studies were considered to have a low risk of bias in any domain. It is not possible to blind participants and clinicians to physiotherapy interventions, but 10 studies did blind the outcome assessors.Forced expiratory volume in one second was the most frequently measured outcome. One long-term study (seven months) compared oscillatory devices with either conventional physiotherapy or breathing techniques and found statistically significant differences in some lung function parameters in favour of oscillating devices. One study identified an increase in frequency of exacerbations requiring antibiotics whilst using high frequency chest wall oscillation when compared to positive expiratory pressure. There were some small but significant changes in secondary outcome variables such as sputum volume or weight, but not wholly in favour of oscillating devices. Participant satisfaction was reported in 15 studies but this was not specifically in favour of an oscillating device, as some participants preferred breathing techniques or techniques used prior to the study interventions. The results for the remaining outcome measures were not examined or reported in sufficient detail to provide any high level evidence. There was no clear evidence that oscillation was a more or less effective intervention overall than other forms of physiotherapy; furthermore there was no evidence that one device is superior to another. The findings from one study showing an increase in frequency of exacerbations requiring antibiotics whilst using an oscillating device compared to positive expiratory pressure may have significant resource implications. More adequately-powered long-term randomised controlled trials are necessary and outcomes measured should include frequency of exacerbations, patient preference, adherence to therapy and general satisfaction with treatment. Increased adherence to therapy may then lead to improvements in other parameters, such as exercise tolerance and respiratory function. Additional evidence is needed to evaluate whether oscillating devices combined with other forms of airway clearance is efficacious in people with cystic fibrosis.
Garner, Alan A; Hsu, Jeremy; McShane, Anne; Sroor, Adam
Increased fracture displacement has previously been described with the application of pelvic circumferential compression devices (PCCDs) in patients with lateral compression-type pelvic fracture. We describe the first reported case of hemodynamic deterioration temporally associated with the prehospital application of a PCCD in a patient with a complex acetabular fracture with medial displacement of the femoral head. Active hemorrhage from a site adjacent to the acetabular fracture was subsequently demonstrated on angiography. Caution in the application of PCCDs to patients with lateral compression-type fractures is warranted. Copyright © 2017 Air Medical Journal Associates. All rights reserved.
Evaluation of Infrared Thermometry in Cynomolgus Macaques (Macaca fascicularis)
Laffins, Michael M; Mellal, Nacera; Almlie, Cynthia L; Regalia, Douglas E
2017-01-01
Recording an accurate body temperature is important to assess an animal's health status. We compared temperature data from sedated cynomolgus macaques (Macaca fascicularis) to evaluate differences between rectal, infrared (inguinal and chest), and implanted telemetry techniques with the objective of demonstrating the diagnostic equivalence of the infrared device with other approaches. Infrared thermometer readings are instantaneous and require no contact with the animal. Body temperature data were obtained from 205 (137 male, 68 female) cynomolgus macaques under ketamine (10 mg/kg IM) sedation over a 3-mo period during scheduled physical examinations. Infrared measurements were taken 5 cm from the chest and inguinal areas. We evaluated 10 (9 functional devices) sedated cynomolgus macaques (5 male, 5 female) implanted with telemetry units in a muscular pouch between the internal and external abdominal oblique muscles. We determined that the mean body temperature acquired by using telemetry did not differ from either the mean of inguinal and chest infrared measurements but did differ from the mean of temperature obtained rectally. In addition, the mean rectal temperature differed from the mean of the inguinal reading but not the mean of the chest temperature. The results confirm our hypothesis that the infrared thermometer can be used to replace standard rectal thermometry. PMID:28905720
Method for preventing jamming conditions in a compression device
Williams, Paul M.; Faller, Kenneth M.; Bauer, Edward J.
2002-06-18
A compression device for feeding a waste material to a reactor includes a waste material feed assembly having a hopper, a supply tube and a compression tube. Each of the supply and compression tubes includes feed-inlet and feed-outlet ends. A feed-discharge valve assembly is located between the feed-outlet end of the compression tube and the reactor. A feed auger-screw extends axially in the supply tube between the feed-inlet and feed-outlet ends thereof. A compression auger-screw extends axially in the compression tube between the feed-inlet and feed-outlet ends thereof. The compression tube is sloped downwardly towards the reactor to drain fluid from the waste material to the reactor and is oriented at generally right angle to the supply tube such that the feed-outlet end of the supply tube is adjacent to the feed-inlet end of the compression tube. A programmable logic controller is provided for controlling the rotational speed of the feed and compression auger-screws for selectively varying the compression of the waste material and for overcoming jamming conditions within either the supply tube or the compression tube.
Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo
2016-04-01
This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease. © IMechE 2016.
21 CFR 870.2350 - Electrocardiograph lead switching adaptor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Electrocardiograph lead switching adaptor. 870... Electrocardiograph lead switching adaptor. (a) Identification. An electrocardiograph lead switching adaptor is a passive switching device to which electrocardiograph limb and chest leads may be attached. This device is...
21 CFR 870.2350 - Electrocardiograph lead switching adaptor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Electrocardiograph lead switching adaptor. 870... Electrocardiograph lead switching adaptor. (a) Identification. An electrocardiograph lead switching adaptor is a passive switching device to which electrocardiograph limb and chest leads may be attached. This device is...
21 CFR 870.2350 - Electrocardiograph lead switching adaptor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Electrocardiograph lead switching adaptor. 870... Electrocardiograph lead switching adaptor. (a) Identification. An electrocardiograph lead switching adaptor is a passive switching device to which electrocardiograph limb and chest leads may be attached. This device is...
Smereka, Jacek; Kasiński, Mariusz; Smereka, Adam; Ładny, Jerzy R; Szarpak, Łukasz
2017-01-01
The aetiology of sudden cardiac arrest in infants is different from that in adults, with respiratory failure, sudden infant death syndrome, and drowning being the primary causes in the former. According to the European Resuscitation Council (ERC) and American Heart Association (AHA) recommendations, the quality of chest compressions (CC) is a key element affecting the effectiveness of cardiopulmonary resuscitation (CPR). The current ERC and AHA guidelines recommend the 'two-finger technique' (TFT) or 'two-thumb encircling hands technique' (TTHT) for external CCs during infant CPR. The aim of the randomised crossover manikin trial was to assess the CC quality during simulated resuscitation in infants performed by paramedics. A prospective, randomised, crossover, single-centre study was conducted between June and August 2016. The study material consisted of 120 fully trained and licensed paramedics (39 females, 32.5%) with a minimum of five years of professional experience (mean 7.5 ± 4.8 years) in emergency medicine (mean age, 30.5 ± 5.5 years). The participants performed CCs using three techniques: TFT (the rescuer compresses the sternum with the tips of two fingers); TTHT; and the 'new two-thumb technique' (nTTT). The novel method of CCs in an infant consists of using two thumbs directed at the angle of 90 degrees to the chest while closing the fingers of both hands in a fist. The median CC rate when using the TFT, the TTHT, and nTTT methods varied and amounted to 134 min-1 vs. 126 min-1 vs. 114 min-1, respectively. There was a statistically significant difference in the median CC frequency between TFT and TTHT (p < 0.001), TFT and nTTT (p < 0.001), and between TTHT and nTTT (p < 0.001). The highest percentage of compressions with the frequency recommended by the ERC guidelines (100-120 min-1) was achieved by the study participants only with the nTTT. The median CC depth during the TFT was 28 mm (interquartile range [IQR] 27-30 mm) and was significantly lower than in the static TTHT (40.5 [IQR 39-41] mm; p < 0.001) and nTTT (40 [IQR 39-41] mm; p < 0.001). The percentage of adequate depth CCs was correctly obtained with TTHT and nTTT. The largest proportion of total decompression of the chest was observed with the nTTT technique (96 [IQR 96-98] %), followed by TFT (95.5 [IQR 85.5-99] %) and TTHT (5 [IQR 3-7] %). In all scenarios, the correct placement of the CC point was achieved in more than 90% of cases. Our novel infant CC method provides the highest percentage of CCs with the frequency recommended by the ERC guidelines as compared with standard techniques. It also allows optimal CC depth.
APPARATUS FOR THE DENSIFICATION AND ENERGIZATION OF CHARGED PARTICLES
Post, R.F.; Coensgen, F.H.
1962-12-18
This patent relates to a device for materially increasing the energy and density of a plasma to produce conditions commensurate with the establishment and promotion of controlled thermonuclear reactions. To this end the device employs three successive stages of magnetic compression, each stage having magnetic mirrors to compress a plasma, the mirrors being moveable to transfer the plasma to successive stages for further compression. Accordingly, a plasma introduced to the first stage is increased in density and energy in stepwide fashion by virtue of the magnetic compression in the successive stages such that the plasma upon reaching the last stage is of extremely high energy and density commensurate the plasma particles undergoing thermonuclear reactions. The principal novelty of the device resides in the provision of a unidirectional magnetic field which increases in stepwise fashion in coaxially communicating compression chambers of progressively decreasing lengths and diameters. Pulsed magnetic fields are superimposed upon the undirectional field and are manipulated to establish resultant magnetic compression fields which increase in intensity and progressively move, with respect to time, through the compression chambers in the direction of the smallest one thereof. The resultant field in the last compression chamber is hence of relatively high intensity, and the density and energy of the plasma confined therein are correspondingly high. (AEC)
Cardiopulmonary resuscitation duty cycle in out-of-hospital cardiac arrest.
Johnson, Bryce V; Johnson, Bryce; Coult, Jason; Fahrenbruch, Carol; Blackwood, Jennifer; Sherman, Larry; Kudenchuk, Peter; Sayre, Michael; Rea, Thomas
2015-02-01
Duty cycle is the portion of time spent in compression relative to total time of the compression-decompression cycle. Guidelines recommend a 50% duty cycle based largely on animal investigation. We undertook a descriptive evaluation of duty cycle in human resuscitation, and whether duty cycle correlates with other CPR measures. We calculated the duty cycle, compression depth, and compression rate during EMS resuscitation of 164 patients with out-of-hospital ventricular fibrillation cardiac arrest. We captured force recordings from a chest accelerometer to measure ten-second CPR epochs that preceded rhythm analysis. Duty cycle was calculated using two methods. Effective compression time (ECT) is the time from beginning to end of compression divided by total period for that compression-decompression cycle. Area duty cycle (ADC) is the ratio of area under the force curve divided by total area of one compression-decompression cycle. We evaluated the compression depth and compression rate according to duty cycle quartiles. There were 369 ten-second epochs among 164 patients. The median duty cycle was 38.8% (SD=5.5%) using ECT and 32.2% (SD=4.3%) using ADC. A relatively shorter compression phase (lower duty cycle) was associated with greater compression depth (test for trend <0.05 for ECT and ADC) and slower compression rate (test for trend <0.05 for ADC). Sixty-one of 164 patients (37%) survived to hospital discharge. Duty cycle was below the 50% recommended guideline, and was associated with compression depth and rate. These findings provider rationale to incorporate duty cycle into research aimed at understanding optimal CPR metrics. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Image compression system and method having optimized quantization tables
NASA Technical Reports Server (NTRS)
Ratnakar, Viresh (Inventor); Livny, Miron (Inventor)
1998-01-01
A digital image compression preprocessor for use in a discrete cosine transform-based digital image compression device is provided. The preprocessor includes a gathering mechanism for determining discrete cosine transform statistics from input digital image data. A computing mechanism is operatively coupled to the gathering mechanism to calculate a image distortion array and a rate of image compression array based upon the discrete cosine transform statistics for each possible quantization value. A dynamic programming mechanism is operatively coupled to the computing mechanism to optimize the rate of image compression array against the image distortion array such that a rate-distortion-optimal quantization table is derived. In addition, a discrete cosine transform-based digital image compression device and a discrete cosine transform-based digital image compression and decompression system are provided. Also, a method for generating a rate-distortion-optimal quantization table, using discrete cosine transform-based digital image compression, and operating a discrete cosine transform-based digital image compression and decompression system are provided.
Holmqvist, Kristian; Davidsson, Johan; Mendoza-Vazquez, Manuel; Rundberget, Peter; Svensson, Mats Y; Thorn, Stefan; Törnvall, Fredrik
2014-01-01
The main aim of this study was to improve the quality of injury risk assessments in steering wheel rim to chest impacts when using the Hybrid III crash test dummy in frontal heavy goods vehicle (HGV) collision tests. Correction factors for chest injury criteria were calculated as the model chest injury parameter ratios between finite element (FE) Hybrid III, evaluated in relevant load cases, and the Total Human Model for Safety (THUMS). This is proposed to be used to compensate Hybrid III measurements in crash tests where steering wheel rim to chest impacts occur. The study was conducted in an FE environment using an FE-Hybrid III model and the THUMS. Two impactor shapes were used, a circular hub and a long, thin horizontal bar. Chest impacts at velocities ranging from 3.0 to 6.0 m/s were simulated at 3 impact height levels. A ratio between FE-Hybrid III and THUMS chest injury parameters, maximum chest compression C max, and maximum viscous criterion VC max, were calculated for the different chest impact conditions to form a set of correction factors. The definition of the correction factor is based on the assumption that the response from a circular hub impact to the middle of the chest is well characterized and that injury risk measures are independent of impact height. The current limits for these chest injury criteria were used as a basis to develop correction factors that compensate for the limitations in biofidelity of the Hybrid III in steering wheel rim to chest impacts. The hub and bar impactors produced considerably higher C max and VC max responses in the THUMS compared to the FE-Hybrid III. The correction factor for the responses of the FE-Hybrid III showed that the criteria responses for the bar impactor were consistently overestimated. Ratios based on Hybrid III and THUMS responses provided correction factors for the Hybrid III responses ranging from 0.84 to 0.93. These factors can be used to estimate C max and VC max values when the Hybrid III is used in crash tests for which steering wheel rim to chest interaction occurs. For the FE-Hybrid III, bar impacts caused higher chest deflection compared to hub impacts, although the contrary results were obtained with the more humanlike THUMS. Correction factors were developed that can be used to correct the Hybrid III chest responses. Higher injury criteria capping limits for steering wheel impacts are acceptable. Supplemental materials are available for this article. Go to the publisher's online edition of Traffic Injury Prevention to view the supplemental file.
Altered Standards of Care: An Analysis of Existing Federal, State, and Local Guidelines
2011-12-01
Approved for public release; distribution is unlimited 12b. DISTRIBUTION CODE A 13. ABSTRACT (maximum 200 words ) A...data systems for communications and the transference of data. Losing data systems during disasters cuts off access to electronic medical records...emergency procedures as mouth - to- mouth resuscitation, external chest compression, electric shock, insertion of a tube to open the patient’s airway
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gowitt, G.T.; Hanzlick, R.L.
1992-06-01
So-called typical' autoerotic fatalities are the result of asphyxia due to mechanical compression of the neck, chest, or abdomen, whereas atypical' autoeroticism involves sexual self-stimulation by other means. The authors present five atypical autoerotic fatalities that involved the use of dichlorodifluoromethane, nitrous oxide, isobutyl nitrite, cocaine, or compounds containing 1-1-1-trichloroethane. Mechanisms of death are discussed in each case and the pertinent literature is reviewed.
Protective carrier for microcircuit devices
Robinson, Lyle A.
1976-10-26
An improved protective carrier for microcircuit devices having beam leads wherein a compressible member is disposed on the carrier base beneath and overlapping the periphery of an aperture in a flexible circuit element, the element being adapted to receive and make electrical contact with microcircuit device beam leads, the compressible member disposed or arranged to achieve flexing of the circuit element against the microcircuit device beam leads to conform to variations in thicknesses of the device beam leads or circuit element electrical paths and thereby insure electrical connection between the beam leads and the electrical paths.
Peterson, P Gabriel; Pak, Sung K; Nguyen, Binh; Jacobs, Genevieve; Folio, Les
2012-12-01
This study aims to evaluate the utility of compressed computed tomography (CT) studies (to expedite transmission) using Motion Pictures Experts Group, Layer 4 (MPEG-4) movie formatting in combat hospitals when guiding major treatment regimens. This retrospective analysis was approved by Walter Reed Army Medical Center institutional review board with a waiver for the informed consent requirement. Twenty-five CT chest, abdomen, and pelvis exams were converted from Digital Imaging and Communications in Medicine to MPEG-4 movie format at various compression ratios. Three board-certified radiologists reviewed various levels of compression on emergent CT findings on 25 combat casualties and compared with the interpretation of the original series. A Universal Trauma Window was selected at -200 HU level and 1,500 HU width, then compressed at three lossy levels. Sensitivities and specificities for each reviewer were calculated along with 95 % confidence intervals using the method of general estimating equations. The compression ratios compared were 171:1, 86:1, and 41:1 with combined sensitivities of 90 % (95 % confidence interval, 79-95), 94 % (87-97), and 100 % (93-100), respectively. Combined specificities were 100 % (85-100), 100 % (85-100), and 96 % (78-99), respectively. The introduction of CT in combat hospitals with increasing detectors and image data in recent military operations has increased the need for effective teleradiology; mandating compression technology. Image compression is currently used to transmit images from combat hospital to tertiary care centers with subspecialists and our study demonstrates MPEG-4 technology as a reasonable means of achieving such compression.
Donoghue, Aaron; Hsieh, Ting-Chang; Myers, Sage; Mak, Allison; Sutton, Robert; Nadkarni, Vinay
2015-06-01
To describe the adherence to guidelines for CPR in a tertiary pediatric emergency department (ED) where resuscitations are reviewed by videorecording. Resuscitations in a tertiary pediatric ED are videorecorded as part of a quality improvement project. Patients receiving CPR under videorecorded conditions were eligible for inclusion. CPR parameters were quantified by retrospective review. Data were described by 30-s epoch (compression rate, ventilation rate, compression:ventilation ratio), by segment (duration of single providers' compressions) and by overall event (compression fraction). Duration of interruptions in compressions was measured; tasks completed during pauses were tabulated. 33 children received CPR under videorecorded conditions. A total of 650 min of CPR were analyzed. Chest compressions were performed at <100/min in 90/714 (13%) of epochs; 100-120/min in 309/714 (43%); >120/min in 315/714 (44%). Ventilations were 6-12 breaths/min in 201/708 (23%) of epochs and >12/min in 489/708 (70%). During CPR without an artificial airway, compression:ventilation coordination (15:2) was done in 93/234 (40%) of epochs. 178 pauses in CPR occurred; 120 (67%) were <10s in duration. Of 370 segments of compressions by individual providers, 282/370 (76%) were <2 min in duration. Median compression fraction was 91% (range 88-100%). CPR in a tertiary pediatric ED frequently met recommended parameters for compression rate, pause duration, and compression fraction. Hyperventilation and failure of C:V coordination were very common. Future studies should focus on the impact of training methods on CPR performance as documented by videorecording. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Nyström, Gustav; Marais, Andrew; Karabulut, Erdem; Wågberg, Lars; Cui, Yi; Hamedi, Mahiar M.
2015-01-01
Traditional thin-film energy-storage devices consist of stacked layers of active films on two-dimensional substrates and do not exploit the third dimension. Fully three-dimensional thin-film devices would allow energy storage in bulk materials with arbitrary form factors and with mechanical properties unique to bulk materials such as compressibility. Here we show three-dimensional energy-storage devices based on layer-by-layer self-assembly of interdigitated thin films on the surface of an open-cell aerogel substrate. We demonstrate a reversibly compressible three-dimensional supercapacitor with carbon nanotube electrodes and a three-dimensional hybrid battery with a copper hexacyanoferrate ion intercalating cathode and a carbon nanotube anode. The three-dimensional supercapacitor shows stable operation over 400 cycles with a capacitance of 25 F g−1 and is fully functional even at compressions up to 75%. Our results demonstrate that layer-by-layer self-assembly inside aerogels is a rapid, precise and scalable route for building high-surface-area 3D thin-film devices. PMID:26021485
Acute spinal cord compression: a rare complication of dual antiplatelet therapy
Iskandar, Muhammad Zaid; Chong, Victor; Hutcheon, Stuart
2015-01-01
A 73-year-old woman presented with acute shortness of breath and exacerbation of chronic back pain. She was diagnosed with pulmonary oedema and a non-ST-elevation myocardial infarction following chest X-ray, ECG and high sensitivity troponin levels. She subsequently underwent coronary angioplasty with deployment of drug-eluting stents to her circumflex and left anterior descending arteries and was started on aspirin and clopidogrel for her dual antiplatelet therapy. Unfortunately, following the procedure, she gradually lost power and sensation in both lower limbs. MRI of her spine confirmed an extradural haematoma causing thoracic cord compression. She was managed conservatively following discussions with neurosurgeons and developed further complications secondary to her immobility. PMID:26202314
Chest radiography practice in critically ill patients: a postal survey in the Netherlands
Graat, Marleen E; Hendrikse, Karin A; Spronk, Peter E; Korevaar, Johanna C; Stoker, Jaap; Schultz, Marcus J
2006-01-01
Background To ascertain current chest radiography practice in intensive care units (ICUs) in the Netherlands. Methods Postal survey: a questionnaire was sent to all ICUs with > 5 beds suitable for mechanical ventilation; pediatric ICUs were excluded. When an ICU performed daily-routine chest radiographs in any group of patients it was considered to be a "daily-routine chest radiography" ICU. Results From the number of ICUs responding, 63% practice a daily-routine strategy, in which chest radiographs are obtained on a daily basis without any specific reason. A daily-routine chest radiography strategy is practiced less frequently in university-affiliated ICUs (50%) as compared to other ICUs (68%), as well as in larger ICUs (> 20 beds, 50%) as compared to smaller ICUs (< 20 beds, 65%) (P > 0.05). Remarkably, physicians that practice a daily-routine strategy consider daily-routine radiographs helpful in guiding daily practice in less than 30% of all performed radiographs. Chest radiographs are considered essential for verification of the position of invasive devices (81%) and for diagnosing pneumothorax, pneumonia or acute respiratory distress syndrome (82%, 74% and 69%, respectively). On demand chest radiographs are obtained after introduction of thoracic drains, central venous lines and endotracheal tubes in 98%, 84% and 75% of responding ICUs, respectively. Chest films are also obtained in case of ventilatory deterioration (49% of responding ICUs), and after cardiopulmonary resuscitation (59%), tracheotomy (58%) and mini-tracheotomy (23%). Conclusion There is notable lack of consensus on chest radiography practice in the Netherlands. This survey suggests that a large number of intensivists may doubt the value of daily-routine chest radiography, but still practice a daily-routine strategy. PMID:16848892
[Features of cranio-cerebral trauma in victims of road accidents].
Ogleznev, K Ia; Stankevich, P V
2001-01-01
The paper deals with the specific features of brain injury (BI) in victims of road traffic accidents (RTA). RTA victims are most commonly pedestrians (62.6%) and less commonly drivers (17.5%). In over half the cases (62.6%), BI due to RTA is associated with extracranial lesions, leading to diagnostic problems. The pattern and site of lesions are related to the type of a transport vehicle and to the role of a victim as a traffic participant. Multiple extracranial lesions are mostly frequently encountered in victim pedestrians (30.3%), BI concurrent with chest damage is common in drivers (12.8%), BI concurrent with "whip" injury of the cervical spine is found in drivers and passengers though such combinations may also seen in pedestrians (1.5%--5 cases). The most severe form of brain compression is multifactorial compression (27.6%) and its most common form is compression with subdural hematoma (35.3%).
Jones, Christopher M; Owen, Andrew; Thorne, Christopher J; Hulme, Jonathan
2012-08-09
Effective delivery of cardiopulmonary resuscitation (CPR) and prompt defibrillation following sudden cardiac arrest (SCA) is vital. Updated guidelines for adult basic life support (BLS) were published in 2010 by the European Resuscitation Council (ERC) in an effort to improve survival following SCA. There has been little assessment of the ability of rescuers to meet the standards outlined within these new guidelines. We conducted a retrospective analysis of the performance of first year healthcare students trained and assessed using either the new 2010 ERC guidelines or their 2005 predecessor, within the University of Birmingham, United Kingdom. All students were trained as lay rescuers during a standardised eight hour ERC-accredited adult BLS course. We analysed the examination records of 1091 students. Of these, 561 were trained and assessed using the old 2005 ERC guidelines and 530 using the new 2010 guidelines. A significantly greater proportion of candidates failed in the new guideline group (16.04% vs. 11.05%; p < 0.05), reflecting a significantly greater proportion of lay-rescuers performing chest compressions at too fast a rate when trained and assessed with the 2010 rather than 2005 guidelines (6.04% vs. 2.67%; p < 0.05). Error rates for other skills did not differ between guideline groups. The new ERC guidelines lead to a greater proportion of lay rescuers performing chest compressions at an erroneously fast rate and may therefore worsen BLS efficacy. Additional study is required in order to define the clinical impact of compressions performed to a greater depth and at too fast a rate.
Retrofit device and method to improve humidity control of vapor compression cooling systems
Roth, Robert Paul; Hahn, David C.; Scaringe, Robert P.
2016-08-16
A method and device for improving moisture removal capacity of a vapor compression system is disclosed. The vapor compression system is started up with the evaporator blower initially set to a high speed. A relative humidity in a return air stream is measured with the evaporator blower operating at the high speed. If the measured humidity is above the predetermined high relative humidity value, the evaporator blower speed is reduced from the initially set high speed to the lowest possible speed. The device is a control board connected with the blower and uses a predetermined change in measured relative humidity to control the blower motor speed.
Hot-compress: A new postdeposition treatment for ZnO-based flexible dye-sensitized solar cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haque Choudhury, Mohammad Shamimul, E-mail: shamimul129@gmail.com; Department of Electrical and Electronic Engineering, International Islamic University Chittagong, b154/a, College Road, Chittagong 4203; Kishi, Naoki
2016-08-15
Highlights: • A new postdeposition treatment named hot-compress is introduced. • Hot-compression gives homogeneous compact layer ZnO photoanode. • I-V and EIS analysis data confirms the efficacy of this method. • Charge transport resistance was reduced by the application of hot-compression. - Abstract: This article introduces a new postdeposition treatment named hot-compress for flexible zinc oxide–base dye-sensitized solar cells. This postdeposition treatment includes the application of compression pressure at an elevated temperature. The optimum compression pressure of 130 Ma at an optimum compression temperature of 70 °C heating gives better photovoltaic performance compared to the conventional cells. The aptness ofmore » this method was confirmed by investigating scanning electron microscopy image, X-ray diffraction, current-voltage and electrochemical impedance spectroscopy analysis of the prepared cells. Proper heating during compression lowers the charge transport resistance, longer the electron lifetime of the device. As a result, the overall power conversion efficiency of the device was improved about 45% compared to the conventional room temperature compressed cell.« less
Compression device for feeding a waste material to a reactor
Williams, Paul M.; Faller, Kenneth M.; Bauer, Edward J.
2001-08-21
A compression device for feeding a waste material to a reactor includes a waste material feed assembly having a hopper, a supply tube and a compression tube. Each of the supply and compression tubes includes feed-inlet and feed-outlet ends. A feed-discharge valve assembly is located between the feed-outlet end of the compression tube and the reactor. A feed auger-screw extends axially in the supply tube between the feed-inlet and feed-outlet ends thereof. A compression auger-screw extends axially in the compression tube between the feed-inlet and feed-outlet ends thereof. The compression tube is sloped downwardly towards the reactor to drain fluid from the waste material to the reactor and is oriented at generally right angle to the supply tube such that the feed-outlet end of the supply tube is adjacent to the feed-inlet end of the compression tube. A programmable logic controller is provided for controlling the rotational speed of the feed and compression auger-screws for selectively varying the compression of the waste material and for overcoming jamming conditions within either the supply tube or the compression tube.
Asymptomatic Presentation of Large Cardiac Hydatid.
Beedkar, Amey; Parikh, Rohan; Deshmukh, Pradeep
2017-02-01
Hydatid cyst is a tissue parasitic infection caused by tapeworm Echinococcus granulosus. Common location for hydatid cysts are the liver (65%) and the lungs (25%). Cardiac hydatid cyst is seen rarely, occurring in about 0.5-2% of all cases of hydatid disease. We present this case of 45 years female who presented with short duration of dry cough and atypical chest pain. Chest X ray showed cardiomegaly with round bulge at the right heart border and curvilinear calcification in left upper abdomen in the region of spleen. Transthoracic echocardiography (TTE) depicted cystic lesion in Right Ventricle free wall causing compression of right atrial and ventricular cavity. Cardiac CT confirmed this cyst as hydatid cyst. Patient underwent successful excision of right ventricular hydatid cyst. © Journal of the Association of Physicians of India 2011.
Nineth Rib Syndrome after 10(th) Rib Resection.
Yu, Hyun Jeong; Jeong, Yu Sub; Lee, Dong Hoon; Yim, Kyoung Hoon
2016-07-01
The 12(th) rib syndrome is a disease that causes pain between the upper abdomen and the lower chest. It is assumed that the impinging on the nerves between the ribs causes pain in the lower chest, upper abdomen, and flank. A 74-year-old female patient visited a pain clinic complaining of pain in her back, and left chest wall at a 7 on the 0-10 Numeric Rating scale (NRS). She had a lateral fixation at T12-L2, 6 years earlier. After the operation, she had multiple osteoporotic compression fractures. When the spine was bent, the patient complained about a sharp pain in the left mid-axillary line and radiating pain toward the abdomen. On physical examination, the 10(th) rib was not felt, and an image of the rib-cage confirmed that the left 10(th) rib was severed. When applying pressure from the legs to the 9(th) rib of the patient, pain was reproduced. Therefore, the patient was diagnosed with 9(th) rib syndrome, and ultrasound-guided 9(th) and 10(th) intercostal nerve blocks were performed around the tips of the severed 10(th) rib. In addition, local anesthetics with triamcinolone were administered into the muscles beneath the 9(th) rib at the point of the greatest tenderness. The patient's pain was reduced to NRS 2 point. In this case, it is suspected that the patient had a partial resection of the left 10(th) rib in the past, and subsequent compression fractures at T8 and T9 led to the deformation of the rib cage, causing the tip of the remaining 10(th) rib to impinge on the 9(th) intercostal nerves, causing pain.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Evaluation of three different devices to reduce stasis edema in poorly mobile nursing home patients.
Benigni, Jean-Patrick; Uhl, Jean-François; Balet, Florence; Filori, Pascal; Chahim, Maxime
2018-03-08
Prolonged immobility in the sitting position in the elderly is known to produce venous stasis with leg edema and possible skin changes. Compression stockings are often applied for this clinical problem. There are few experienced nursing staff available to supervise the difficult task of stocking application. The authors have researched other effective and simple devices that may be suitable alternatives. This article reports the results of three different devices to reduce leg edema, as measured by reduction in leg volume : an electro- stimulation device, an adjustable compression Velcro® wrap and a short stretch bandage, each tested over a two-hour period. In this randomized pilot study including 38 patients, the authors observed no difference in leg volume following electro-stimulation (Veinoplus®). They noted a significant reduction in leg volume following use of the other two devices, more with the adjustable Velcro® wrap compression (Circaid Juxtafit®) than with the short stretch bandage (Rosidal K®). Measurement of the interface pressures created by these two devices and also assessing the stiffness created by applying each device for two hours confirm that pressure is more important than stiffness in the reduction of edema in these particular patients. This pilot study is to be added to the results of previous published studies showing the efficacy in reducting leg edema of Velcro® adjustable compression wrap and its ease of use.
NASA Technical Reports Server (NTRS)
1972-01-01
The assembly drawings of the receiver unit are presented for the data compression/error correction digital test system. Equipment specifications are given for the various receiver parts, including the TV input buffer register, delta demodulator, TV sync generator, memory devices, and data storage devices.
Theory of energy harvesting from heartbeat including the effects of pleural cavity and respiration.
Zhang, Yangyang; Lu, Bingwei; Lü, Chaofeng; Feng, Xue
2017-11-01
Self-powered implantable devices with flexible energy harvesters are of significant interest due to their potential to solve the problem of limited battery life and surgical replacement. The flexible electronic devices made of piezoelectric materials have been employed to harvest energy from the motion of biological organs. Experimental measurements show that the output voltage of the device mounted on porcine left ventricle in chest closed environment decreases significantly compared to the case of chest open. A restricted-space deformation model is proposed to predict the impeding effect of pleural cavity, surrounding tissues, as well as respiration on the efficiency of energy harvesting from heartbeat using flexible piezoelectric devices. The analytical solution is verified by comparing theoretical predictions to experimental measurements. A simple scaling law is established to analyse the intrinsic correlations between the normalized output power and the combined system parameters, i.e. the normalized permitted space and normalized electrical load. The results may provide guidelines for optimization of in vivo energy harvesting from heartbeat or the motions of other biological organs using flexible piezoelectric energy harvesters.
Theory of energy harvesting from heartbeat including the effects of pleural cavity and respiration
NASA Astrophysics Data System (ADS)
Zhang, Yangyang; Lu, Bingwei; Lü, Chaofeng; Feng, Xue
2017-11-01
Self-powered implantable devices with flexible energy harvesters are of significant interest due to their potential to solve the problem of limited battery life and surgical replacement. The flexible electronic devices made of piezoelectric materials have been employed to harvest energy from the motion of biological organs. Experimental measurements show that the output voltage of the device mounted on porcine left ventricle in chest closed environment decreases significantly compared to the case of chest open. A restricted-space deformation model is proposed to predict the impeding effect of pleural cavity, surrounding tissues, as well as respiration on the efficiency of energy harvesting from heartbeat using flexible piezoelectric devices. The analytical solution is verified by comparing theoretical predictions to experimental measurements. A simple scaling law is established to analyse the intrinsic correlations between the normalized output power and the combined system parameters, i.e. the normalized permitted space and normalized electrical load. The results may provide guidelines for optimization of in vivo energy harvesting from heartbeat or the motions of other biological organs using flexible piezoelectric energy harvesters.
... medicine. Severe cases require additional treatment, such as: Artificial pacemaker. The electronic device is placed under the skin on your chest. It helps your heart maintain a regular beat. Cardiac defibrillation. A brief ...
NASA Astrophysics Data System (ADS)
Waye, A. B.; Krygiel, R. G.; Susin, T. B.; Baptista, R.; Rehnberg, L.; Heidner, G. S.; de Campos, F.; Falcão, F. P.; Russomano, T.
2013-09-01
Performance of efficient single-person cardiopulmonary resuscitation (CPR) is vital to maintain cardiac and cerebral perfusion during the 2-4 min it takes for deployment of advanced life support during a space mission. The aim of the present study was to investigate potential differences in upper body muscle activity during CPR performance at terrestrial gravity (+1Gz) and in simulated microgravity (μG). Muscle activity of the triceps brachii, erector spinae, rectus abdominis and pectoralis major was measured via superficial electromyography in 20 healthy male volunteers. Four sets of 30 external chest compressions (ECCs) were performed on a mannequin. Microgravity was simulated using a body suspension device and harness; the Evetts-Russomano (ER) method was adopted for CPR performance in simulated microgravity. Heart rate and perceived exertion via Borg scores were also measured. While a significantly lower depth of ECCs was observed in simulated microgravity, compared with +1Gz, it was still within the target range of 40-50 mm. There was a 7.7% decrease of the mean (±SEM) ECC depth from 48 ± 0.3 mm at +1Gz, to 44.3 ± 0.5 mm during microgravity simulation (p < 0.001). No significant difference in number or rate of compressions was found between the two conditions. Heart rate displayed a significantly larger increase during CPR in simulated microgravity than at +1Gz, the former presenting a mean (±SEM) of 23.6 ± 2.91 bpm and the latter, 76.6 ± 3.8 bpm (p < 0.001). Borg scores were 70% higher post-microgravity compressions (17 ± 1) than post +1Gz compressions (10 ± 1) (p < 0.001). Intermuscular comparisons showed the triceps brachii to have significantly lower muscle activity than each of the other three tested muscles, in both +1Gz and microgravity. As shown by greater Borg scores and heart rate increases, CPR performance in simulated microgravity is more fatiguing than at +1Gz. Nevertheless, no significant difference in muscle activity between conditions was found, a result that is favourable for astronauts, given the inevitable muscular and cardiovascular deconditioning that occurs during space travel.
Mauroy, Benjamin; Flaud, Patrice; Pelca, Dominique; Fausser, Christian; Merckx, Jacques; Mitchell, Barrett R.
2015-01-01
Chest physiotherapy is an empirical technique used to help secretions to get out of the lung whenever stagnation occurs. Although commonly used, little is known about the inner mechanisms of chest physiotherapy and controversies about its use are coming out regularly. Thus, a scientific validation of chest physiotherapy is needed to evaluate its effects on secretions. We setup a quasi-static numerical model of chest physiotherapy based on thorax and lung physiology and on their respective biophysics. We modeled the lung with an idealized deformable symmetric bifurcating tree. Bronchi and their inner fluids mechanics are assumed axisymmetric. Static data from the literature is used to build a model for the lung's mechanics. Secretions motion is the consequence of the shear constraints apply by the air flow. The input of the model is the pressure on the chest wall at each time, and the output is the bronchi geometry and air and secretions properties. In the limit of our model, we mimicked manual and mechanical chest physiotherapy techniques. We show that for secretions to move, air flow has to be high enough to overcome secretion resistance to motion. Moreover, the higher the pressure or the quicker it is applied, the higher is the air flow and thus the mobilization of secretions. However, pressures too high are efficient up to a point where airways compressions prevents air flow to increase any further. Generally, the first effects of manipulations is a decrease of the airway tree hydrodynamic resistance, thus improving ventilation even if secretions do not get out of the lungs. Also, some secretions might be pushed deeper into the lungs; this effect is stronger for high pressures and for mechanical chest physiotherapy. Finally, we propose and tested two a dimensional numbers that depend on lung properties and that allow to measure the efficiency and comfort of a manipulation. PMID:26300780
Atamanyuk, Iryna; Ghez, Olivier; Saeed, Imran; Lane, Mary; Hall, Judith; Jackson, Tim; Desai, Ajay; Burmester, Margarita
2014-01-01
To develop an affordable realistic open-chest extracorporeal membrane oxygenation (ECMO) model for embedded in situ interprofessional crisis resource management training in emergency management of a post-cardiac surgery child. An innovative attachment to a high-fidelity mannequin (Laerdal Simbaby) was used to enable a cardiac tamponade/ECMO standstill scenario. Two saline bags with blood dye were placed over the mannequin's chest. A 'heart' bag with venous and arterial outlets was connected to the corresponding tubes of the ECMO circuit. The bag was divided into arterial and venous parts by loosely wrapping silicon tubing around its centre. A 'pericardial' bag was placed above it. Both were then covered by a chest skin that had a sutured silicone membrane window. False blood injected into the 'pericardial' bag caused expansion leading to (i) bulging of silastic membrane, simulating tamponade, and (ii) compression of tubing around the 'heart' bag, creating negative venous pressures and cessation of ECMO flow. In situ Simulation Paediatric Resuscitation Team Training (SPRinT) was performed on paediatric intensive care unit; the course included a formal team training/scenario of an open-chest ECMO child with acute cardiac tamponade due to blocked chest drains/debriefing by trained facilitators. Cardiac tamponade was reproducible, and ECMO flow/circuit pressure changes were effective and appropriate. There were eight participants: one cardiac surgeon, two intensivists, one cardiologist, one perfusionist and three nurses. Five of the eight reported the realism of the model and 6/8 the realism of the clinical scenario as highly effective. Eight of eight reported a highly effective impact on (i) their practice and (ii) teamwork. Six of eight reported a highly effective impact on communication skills and increased confidence in attending future real events. Innovative adaptation of a high-fidelity mannequin for open-chest ECMO simulation can achieve a realistic and reproducible training model. The impact on interprofessional team training is promising but needs to be validated further.
Clinical experience with orthotic repair of pectus carinatum.
Al-Githmi, Iskander S
2016-01-01
Pectus carinatum is a congenital chest wall deformity characterized by protrusion of the sternum and adjacent costal cartilages. Multiple treatment options are available for correction of pectus carinatum. We report our initial experience with first-line treatment using a custom fitted dynamic compression orthosis. Prospective evaluation of all patients seen between November 2013 and December 2014. University hospital. The treatment protocol for patients who had pressure for initial correction.
Koyama, Yasuaki; Wada, Takafumi; Lohman, Brandon D; Takamatsu, Yuka; Matsumoto, Junichi; Fujitani, Shigeki; Taira, Yasuhiko
2013-10-01
The objective of the study is to demonstrate the utility of near-infrared spectroscopy (NIRS) in evaluating chest compression (CC) quality in cardiac arrest (CA) patients as well as determine its prognosis predictive value. We present a nonconsecutive case series of adult patients with CA whose cardiopulmonary resuscitation (CPR) was monitored with NIRS and collected the total hemoglobin concentration change (ΔcHb), the tissue oxygen index (TOI), and the ΔTOI to assess CC quality in a noninvasive fashion. During CPR, ΔcHb displayed waveforms monitor, which we regarded as a surrogate for CC quality. Total hemoglobin concentration change waveforms responded accurately to variations or cessations of CCs. In addition, a TOI greater than 40% measured upon admission appears to be significant in predicting patient's outcome. Of 15 patients, 6 had a TOI greater than 40% measured upon admission, and 67% of the latter were in return of spontaneous circulation after CPR and were found to be significantly different between return of spontaneous circulation and death (P = .047; P < .05). Near-infrared spectroscopy reliably assesses the quality of CCs in patients with CA demonstrated by synchronous waveforms during CPR and possible prognostic predictive value, although further investigation is warranted. © 2013 Elsevier Inc. All rights reserved.
[Effectiveness of resuscitation delivered by Polish paramedics].
Guła, Przemysław; Koszowska, Małgorzata; Larysz, Dawid; Koszowski, Marcin; Nabzdyk, Andrzej; Maślanka, Marek
2008-01-01
The aim of the study was to evaluate the effectiveness and skills in BLS and use of automatic external defibrillators (AED) by paramedics from units of the National Fire and Rescue System. One hundred and fifty-eight rescuers participated in the study. They included both volunteers and professionals, and were recruited from 40 different rescue organizations. The results were evaluated by experienced physicians, nurses and paramedics, all holders of ALS and BLS-AED instructor diplomas. The following skills were evaluated: initial assessment, ventilation, chest compression, and use of the AED. The quality of the BLS-AED was rated against the professional experience of the rescuers, and the frequency of repetition training. Although theoretical background was rated good, 45% of participants omitted assessment of consciousness. Airway patency and respiration were properly assessed by 82.5% and 72.5% of paramedics respectively, but only 20% could provide adequate rescue breaths to the phantom victims. Circulation was correctly assessed by 65% of participants, but once again, only 34.4% of paramedics could provide adequate chest compression. The results correlated positively with professional experience, based on the number of rescue missions (0-250, mean 4.3, median 1). The results proved that despite adequate theoretical knowledge, practical skills of paramedics were poor, due to the inadequate time devoted to practical training and the lack of certificate courses.
López-Herce, Jesús; Rodríguez Núñez, Antonio; Maconochie, Ian; Van de Voorde, Patric; Biarent, Dominique; Eich, Christof; Bingham, Robert; Rajka, Thomas; Zideman, David; Carrillo, Ángel; de Lucas, Nieves; Calvo, Custodio; Manrique, Ignacio
2017-07-01
This summary of the European guidelines for pediatric cardiopulmonary resuscitation (CPR) emphasizes the main changes and encourages health care professionals to keep their pediatric CPR knowledge and skills up to date. Basic and advanced pediatric CPR follow the same algorithm in the 2015 guidelines. The main changes affect the prevention of cardiac arrest and the use of fluids. Fluid expansion should not be used routinely in children with fever in the abuse of signs of shock because too high a volume can worsen prognosis. Rescue breaths should last around 1 second in basic CPR, making pediatric recommendations consistent with those for adults. Chest compressions should be at least as deep as one-third the anteroposterior diameter of the thorax. Most children in cardiac arrest lack a shockable rhythm, and in such cases a coordinated sequence of breaths, chest compressions, and administration of adrenalin is essential. An intraosseous canula may be the first choice for introducing fluids and medications, especially in young infants. In treating supraventricular tachycardia with cardioversion, an initial dose of 1 J/kg is currently recommended (vs the dose of 0.5 J/kg previously recommended). After spontaneous circulation is recovered, measures to control fever should be taken. The goal is to reach a normal temperature even before arrival to the hospital.
Kang, Ku Hyun; Song, Keun Jeong; Lee, Chang Hee
2016-01-01
Background. Basic life support (BLS) training with hands-on practice can improve performance during simulated cardiac arrest, although the optimal duration for BLS training is unknown. This study aimed to assess the effectiveness of various BLS training durations for acquiring cardiopulmonary resuscitation (CPR) and automated external defibrillator (AED) skills. Methods. We randomised 485 South Korean nonmedical college students into four levels of BLS training: level 1 (40 min), level 2 (80 min), level 3 (120 min), and level 4 (180 min). Before and after each level, the participants completed questionnaires regarding their willingness to perform CPR and use AEDs, and their psychomotor skills for CPR and AED use were assessed using a manikin with Skill-Reporter™ software. Results. There were no significant differences between levels 1 and 2, although levels 3 and 4 exhibited significant differences in the proportion of overall adequate chest compressions (p < 0.001) and average chest compression depth (p = 0.003). All levels exhibited a greater posttest willingness to perform CPR and use AEDs (all, p < 0.001). Conclusions. Brief BLS training provided a moderate level of skill for performing CPR and using AEDs. However, high-quality skills for CPR required longer and hands-on training, particularly hands-on training with AEDs. PMID:27529066
Lee, Sanghyun; Kim, Wonhee; Kang, Hyunggoo; Oh, Jaehoon; Lim, Tae Ho; Lee, Yoonjae; Kim, Changsun; Cho, Jun Hwi
2015-01-01
Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15° and 30° left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P < 0.05), whereas there was no significant difference between the two video laryngoscopes (in 15° tilt, P = 1; in 30° tilt, P = 0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P < 0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate. PMID:26161426
Caroff, Jildaz; Mihalea, Cristian; Da Ros, Valerio; Yagi, Takanobu; Iacobucci, Marta; Ikka, Léon; Moret, Jacques; Spelle, Laurent
2017-07-01
Recent reports have revealed a worsening of aneurysm occlusion between WEB treatment baseline and angiographic follow-up due to "compression" of the device. We utilized computational fluid dynamics (CFD) in order to determine whether the underlying mechanism of this worsening is flow related. We included data from all consecutive patients treated in our institution with a WEB for unruptured aneurysms located either at the middle cerebral artery or basilar tip. The CFD study was performed using pre-operative 3D rotational angiography. From digital subtraction follow-up angiographies patients were dichotomized into two groups: one with WEB "compression" and one without. We performed statistical analyses to determine a potential correlation between WEB compression and CFD inflow ratio. Between July 2012 and June 2015, a total of 22 unruptured middle cerebral artery or basilar tip aneurysms were treated with a WEB device in our department. Three patients were excluded from the analysis and the mean follow-up period was 17months. Eleven WEBs presented "compression" during follow-up. Interestingly, device "compression" was statistically correlated to the CFD inflow ratio (P=0.018), although not to aneurysm volume, aspect ratio or neck size. The mechanisms underlying the worsening of aneurysm occlusion in WEB-treated patients due to device compression are most likely complex as well as multifactorial. However, it is apparent from our pilot study that a high arterial inflow is, at least, partially involved. Further theoretical and animal research studies are needed to increase our understanding of this phenomenon. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
... arrives. VF is treated by delivering a quick electric shock through the chest. It is done using a device called an external defibrillator. The electric shock can immediately restore the heartbeat to a ...
Electrostimulation's enhancement of recovery during a rugby preseason.
Beaven, C Martyn; Cook, Christian; Gray, David; Downes, Paul; Murphy, Ian; Drawer, Scott; Ingram, John R; Kilduff, Liam P; Gill, Nicholas
2013-01-01
Rugby preseason training involves high-volume strength and conditioning training, necessitating effective management of the recovery-stress state to avoid overtraining and maximize adaptive gains. Compression garments and an electrostimulation device have been proposed to improve recovery by increasing venous blood flow. These devices were assessed using salivary testosterone and cortisol, plasma creatine kinase, and player questionnaires to determine sleep quality, energy level, mood, and enthusiasm. Twenty-five professional rugby players were assigned to 1 of 2 treatments (compression garment or a concurrent combination of electrostimulation and compression) in a crossover design over 2 × 2-wk training blocks. Substantial benefits were observed in self-assessed energy levels (effect size [ES] 0.86), and enthusiasm (ES 0.80) as a result of the combined treatment when compared with compression-garment use. The combination treatment had no discernable effect on salivary hormones, with no treatment effect observed. The electrostimulation device did tend to accelerate the return of creatine kinase to baseline levels after 2 preseason rugby games when compared with the compression-garment intervention (ES 0.61; P = .08). Electrostimulation elicited psychometric and physiological benefits reflective of an improved recovery-stress state in professional male rugby players when combined with a lower-body compression garment.
Kang, Sarah; Niak, Ali; Gada, Neha; Brinker, Allen; Jones, S Christopher
2017-12-01
To describe clinical outcomes of etonogestrel implant patients with migration to the vasculature, chest wall and other distant body sites spontaneously reported to the US Food and Drug Administration Adverse Event Reporting System (FAERS) database. We performed a standardized Medical Dictionary for Regulatory Activities (MedDRA) query in the FAERS database (through November 15, 2015), with reports coded with one or more MedDRA preferred terms that indicate complications with device placement or migration of the device from the original site of insertion to the vasculature, chest wall and other distant body sites. We excluded any cases previously described in the medical literature. We identified 38 cases of pronounced etonogestrel implant migration. Migration locations included the lung/pulmonary artery (n=9), chest wall (n=1), vasculature at locations other than the lung/pulmonary artery (n=14) and extravascular migrations (n=14) to other body sites (e.g., the axilla and clavicle/neck line/shoulder). The majority of cases were asymptomatic and detected when the patient desired implant removal; however, seven cases reported symptoms such as pain, discomfort and dyspnea in association with implant migration. Three cases also describe pulmonary fibrosis and skin reactions as a result of implant migration to the vasculature, chest wall and other distant body sites. Sixteen cases reported surgical removal in an operating room setting. Our FAERS case series demonstrates etonogestrel implant migration to the vasculature, chest wall and other body sites distant from the site of original insertion. As noted by the sponsor in current prescribing information, a key determinant in the risk for etonogestrel contraceptive implant migration appears to be improper insertion technique. Although migration of etonogestrel implants to the vasculature is rare, awareness of migration and education on proper insertion technique may reduce the risk. Published by Elsevier Inc.
Code of Federal Regulations, 2010 CFR
2010-10-01
... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...
Code of Federal Regulations, 2014 CFR
2014-10-01
... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...
Code of Federal Regulations, 2011 CFR
2011-10-01
... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...
Code of Federal Regulations, 2013 CFR
2013-10-01
... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...
Code of Federal Regulations, 2012 CFR
2012-10-01
... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...
Fluid driven torsional dipole seismic source
Hardee, Harry C.
1991-01-01
A compressible fluid powered oscillating downhole seismic source device capable of periodically generating uncontaminated horizontally-propagated, shear waves is provided. A compressible fluid generated oscillation is created within the device which imparts an oscillation to a housing when the device is installed in a housing such as the cylinder off an existing downhole tool, thereby a torsional seismic source is established. Horizontal waves are transferred to the surrounding bore hole medium through downhole clamping.
Xhepa, Erion; Byrne, Robert A; Schulz, Stefanie; Helde, Sandra; Gewalt, Senta; Cassese, Salvatore; Linhardt, Maryam; Ibrahim, Tareq; Mehilli, Julinda; Hoppe, Katharina; Grupp, Katharina; Kufner, Sebastian; Böttiger, Corinna; Hoppmann, Petra; Burgdorf, Christof; Fusaro, Massimiliano; Ott, Ilka; Schneider, Simon; Hengstenberg, Christian; Schunkert, Heribert; Laugwitz, Karl-Ludwig; Kastrati, Adnan
2014-06-01
Vascular closure devices (VCD) have been introduced into clinical practice with the aim of increasing the procedural efficiency and clinical safety of coronary angiography. However, clinical studies comparing VCD and manual compression have yielded mixed results, and large randomised clinical trials comparing the two strategies are missing. Moreover, comparative efficacy studies between different VCD in routine clinical use are lacking. The Instrumental Sealing of ARterial puncture site - CLOSURE device versus manual compression (ISAR-CLOSURE) trial is a prospective, randomised clinical trial designed to compare the outcomes associated with the use of VCD or manual compression to achieve femoral haemostasis. The test hypothesis is that femoral haemostasis after coronary angiography achieved using VCD is not inferior to manual compression in terms of access-site-related vascular complications. Patients undergoing coronary angiography via the common femoral artery will be randomised in a 1:1:1 fashion to receive FemoSeal VCD, EXOSEAL VCD or manual compression. The primary endpoint is the incidence of the composite of arterial access-related complications (haematoma ≥5 cm, pseudoaneurysm, arteriovenous fistula, access-site-related bleeding, acute ipsilateral leg ischaemia, the need for vascular surgical/interventional treatment or documented local infection) at 30 days after randomisation. According to power calculations based on non-inferiority hypothesis testing, enrolment of 4,500 patients is planned. The trial is registered at www.clinicaltrials.gov (study identifier: NCT01389375). The safety of VCD as compared to manual compression in patients undergoing transfemoral coronary angiography remains an issue of clinical equipoise. The aim of the ISAR-CLOSURE trial is to assess whether femoral haemostasis achieved through the use of VCD is non-inferior to manual compression in terms of access-site-related vascular complications.
Albers, C E; Haefeli, P C; Zimmermann, H; de Moya, M; Exadaktylos, A K
2013-05-01
Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our findings. Copyright © 2012 Elsevier Ltd. All rights reserved.
Macho, Jorge Berzosa; Montón, Luis Gardeazabal; Rodriguez, Roberto Cortiñas
2017-08-01
The Cyber Physical Systems (CPS) paradigm is based on the deployment of interconnected heterogeneous devices and systems, so interoperability is at the heart of any CPS architecture design. In this sense, the adoption of standard and generic data formats for data representation and communication, e.g., XML or JSON, effectively addresses the interoperability problem among heterogeneous systems. Nevertheless, the verbosity of those standard data formats usually demands system resources that might suppose an overload for the resource-constrained devices that are typically deployed in CPS. In this work we present Context- and Template-based Compression (CTC), a data compression approach targeted to resource-constrained devices, which allows reducing the resources needed to transmit, store and process data models. Additionally, we provide a benchmark evaluation and comparison with current implementations of the Efficient XML Interchange (EXI) processor, which is promoted by the World Wide Web Consortium (W3C), and it is the most prominent XML compression mechanism nowadays. Interestingly, the results from the evaluation show that CTC outperforms EXI implementations in terms of memory usage and speed, keeping similar compression rates. As a conclusion, CTC is shown to be a good candidate for managing standard data model representation formats in CPS composed of resource-constrained devices.
Montón, Luis Gardeazabal
2017-01-01
The Cyber Physical Systems (CPS) paradigm is based on the deployment of interconnected heterogeneous devices and systems, so interoperability is at the heart of any CPS architecture design. In this sense, the adoption of standard and generic data formats for data representation and communication, e.g., XML or JSON, effectively addresses the interoperability problem among heterogeneous systems. Nevertheless, the verbosity of those standard data formats usually demands system resources that might suppose an overload for the resource-constrained devices that are typically deployed in CPS. In this work we present Context- and Template-based Compression (CTC), a data compression approach targeted to resource-constrained devices, which allows reducing the resources needed to transmit, store and process data models. Additionally, we provide a benchmark evaluation and comparison with current implementations of the Efficient XML Interchange (EXI) processor, which is promoted by the World Wide Web Consortium (W3C), and it is the most prominent XML compression mechanism nowadays. Interestingly, the results from the evaluation show that CTC outperforms EXI implementations in terms of memory usage and speed, keeping similar compression rates. As a conclusion, CTC is shown to be a good candidate for managing standard data model representation formats in CPS composed of resource-constrained devices. PMID:28763013
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-14
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-587] In the Matter of Certain Connecting Devices (``Quick Clamps'') for Use With Modular Compressed Air Conditioning Units, Including Filters, Regulators, and Lubricators (``FRL's'') That Are Part of Larger Pneumatic Systems and the FRL Units They...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-14
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-587] In the Matter of Certain Connecting Devices (``Quick Clamps'') for Use With Modular Compressed Air Conditioning Units, Including Filters, Regulators, and Lubricators (``Frl's'') That Are Part of Larger Pneumatic Systems and the FRL Units They...
The Effect of Head Up Cardiopulmonary Resuscitation on Cerebral and Systemic Hemodynamics.
Ryu, Hyun Ho; Moore, Johanna C; Yannopoulos, Demetris; Lick, Michael; McKnite, Scott; Shin, Sang Do; Kim, Tae Yun; Metzger, Anja; Rees, Jennifer; Tsangaris, Adamantios; Debaty, Guillaume; Lurie, Keith G
2016-05-01
Chest compressions during cardiopulmonary resuscitation (CPR) increase arterial and venous pressures, delivering simultaneous bidirectional high-pressure compression waves to the brain. We hypothesized that this may be detrimental and could be partially overcome by elevation of the head during CPR. Female Yorkshire farm pigs (n=30) were sedated, intubated, anesthetized, and placed on a table able to elevate the head 30° (15cm) (HUP) and the heart 10° (4cm) or remain in the supine (SUP) flat position during CPR. After 8minutes of untreated ventricular fibrillation and 2minutes of SUP CPR, pigs were randomized to HUP or SUP CPR for 20 more minutes. In Group A, pigs were randomized after 2minutes of flat automated conventional (C) CPR to HUP (n=7) or SUP (n=7) C-CPR. In Group B, pigs were randomized after 2minutes of automated active compression decompression (ACD) CPR plus an impedance threshold device (ITD) SUP CPR to either HUP (n=8) or SUP (n=8). The primary outcome of the study was difference in CerPP (mmHg) between the HUP and SUP positions within groups. After 22minutes of CPR, CerPP was 6±3mmHg in the HUP versus -5±3 in the SUP (p=0.016) in Group A, and 51±8 versus 20±5 (p=0.006) in Group B. Coronary perfusion pressures after 22minutes were HUP 6±2 vs SUP 3±2 (p=0.283) in Group A and HUP 32±5 vs SUP 19±5, (p=0.074) in Group B. In Group B, 6/8 pigs were resuscitated in both positions. No pigs were resuscitated in Group A. The HUP position in both C-CPR and ACD+ITD CPR significantly improved CerPP. This simple maneuver has the potential to improve neurological outcomes after cardiac arrest. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chest wall segmentation in automated 3D breast ultrasound scans.
Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico
2013-12-01
In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.
Truszewski, Zenon; Krajewski, Paweł; Fudalej, Marcin; Smereka, Jacek; Frass, Michael; Robak, Oliver; Nguyen, Bianka; Ruetzler, Kurt; Szarpak, Lukasz
2016-01-01
Abstract Background: Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. Methods: ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. Results: The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5–22] sec, when compared to that of sETT at 21.5 [IQR, 20–25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5–24.5] sec (p < .001) and sETT was 27 [IQR, 24.5–31.5] sec. Time to first ventilation for scenario C was 23.5 [IQR, 19–25.5] sec for the ETView and 42.5 [IQR, 35–49.5] sec for sETT. Conclusions: In normal airways and situations with continuous chest compressions, the success rate for intubation of cadavers and the time to ventilation were improved with the ETView. The time to glottis view, tube insertion, and cuff block were all found to be shorter with the ETView. Trial Registration: clinicaltrials.gov Identifier: NCT02733536. PMID:27858851
Truszewski, Zenon; Krajewski, Paweł; Fudalej, Marcin; Smereka, Jacek; Frass, Michael; Robak, Oliver; Nguyen, Bianka; Ruetzler, Kurt; Szarpak, Lukasz
2016-11-01
Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5-22] sec, when compared to that of sETT at 21.5 [IQR, 20-25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5-24.5] sec (p < .001) and sETT was 27 [IQR, 24.5-31.5] sec. Time to first ventilation for scenario C was 23.5 [IQR, 19-25.5] sec for the ETView and 42.5 [IQR, 35-49.5] sec for sETT. In normal airways and situations with continuous chest compressions, the success rate for intubation of cadavers and the time to ventilation were improved with the ETView. The time to glottis view, tube insertion, and cuff block were all found to be shorter with the ETView. clinicaltrials.gov Identifier: NCT02733536.
Medical Treatment for Postthrombotic Syndrome
Palacios, Federico Silva; Rathbun, Suman Wasan
2017-01-01
Deep vein thrombosis (DVT) is a prevalent disease. About 20 to 30% of patients with DVT will develop postthrombotic syndrome (PTS) within months after the initial diagnosis of DVT. There is no gold standard for diagnosis of PTS, but clinical signs include pitting edema, hyperpigmentation, phlebectatic crown, venous eczema, and varicose veins. Several scoring systems have been developed for diagnostic evaluation. Conservative treatment includes compression therapy, medications, lifestyle modification, and exercise. Compression therapy, the mainstay and most proven noninvasive therapy for patients with PTS, can be prescribed as compression stockings, bandaging, adjustable compression wrap devices, and intermittent pneumatic compression. Medications may be used to both prevent and treat PTS and include anticoagulation, anti-inflammatories, vasoactive drugs, antibiotics, and diuretics. Exercise, weight loss, smoking cessation, and leg elevation are also recommended. Areas of further research include the duration, compliance, and strength of compression stockings in the prevention of PTS after DVT; the use of intermittent compression devices; the optimal medical anticoagulant regimen after endovascular therapy; and the role of newer anticoagulants as anti-inflammatory agents. PMID:28265131
Acute spinal cord compression: a rare complication of dual antiplatelet therapy.
Iskandar, Muhammad Zaid; Chong, Victor; Hutcheon, Stuart
2015-07-22
A 73-year-old woman presented with acute shortness of breath and exacerbation of chronic back pain. She was diagnosed with pulmonary oedema and a non-ST-elevation myocardial infarction following chest X-ray, ECG and high sensitivity troponin levels. She subsequently underwent coronary angioplasty with deployment of drug-eluting stents to her circumflex and left anterior descending arteries and was started on aspirin and clopidogrel for her dual antiplatelet therapy. Unfortunately, following the procedure, she gradually lost power and sensation in both lower limbs. MRI of her spine confirmed an extradural haematoma causing thoracic cord compression. She was managed conservatively following discussions with neurosurgeons and developed further complications secondary to her immobility. 2015 BMJ Publishing Group Ltd.
A mobile compression device for thrombosis prevention in hip and knee arthroplasty.
Colwell, Clifford W; Froimson, Mark I; Anseth, Scott D; Giori, Nicholas J; Hamilton, William G; Barrack, Robert L; Buehler, Knute C; Mont, Michael A; Padgett, Douglas E; Pulido, Pamela A; Barnes, C Lowery
2014-02-05
Venous thromboembolic events, either deep venous thrombosis or pulmonary embolism, are important complications in patients undergoing knee or hip arthroplasty. The purpose of this study was to evaluate the effectiveness of a mobile compression device (ActiveCare+S.F.T.) with or without aspirin compared with current pharmacological protocols for prophylaxis against venous thromboembolism in patients undergoing elective primary unilateral arthroplasty of a lower-extremity joint. A multicenter registry was established to capture the rate of symptomatic venous thromboembolic events following primary knee arthroplasty (1551 patients) or hip arthroplasty (1509 patients) from ten sites. All patients were eighteen years of age or older with no known history of venous thromboembolism, coagulation disorder, or solid tumor. Use of the compression device began perioperatively and continued for a minimum of ten days. Patients with symptoms of deep venous thrombosis or pulmonary embolism underwent duplex ultrasonography and/or spiral computed tomography. All patients were evaluated at three months postoperatively to document any evidence of deep venous thrombosis or pulmonary embolism. Of 3060 patients, twenty-eight (0.92%) had venous thromboembolism (twenty distal deep venous thrombi, three proximal deep venous thrombi, and five pulmonary emboli). One death occurred, with no autopsy performed. Symptomatic venous thromboembolic rates observed in patients who had an arthroplasty of a lower-extremity joint using the mobile compression device were noninferior (not worse than), at a margin of 1.0%, to the rates reported for pharmacological prophylaxis, including warfarin, enoxaparin, rivaroxaban, and dabigatran, except in the knee arthroplasty group, in which the mobile compression device fell short of the rate reported for rivaroxaban by 0.06%. Use of the mobile compression device with or without aspirin for patients undergoing arthroplasty of a lower-extremity joint provides a noninferior risk for the development of venous thromboembolism compared with current pharmacological protocols.
... measures such as placement of a breathing tube (mechanical ventilator) and administration of medications intravenously (i.e. ... be regulated. The procedure involves implanting a small mechanical device under the skin of the chest or ...
Mechanical characteristics of the new BONE-LOK bi-cortical internal fixation device.
Cachia, Victor V; Shumway, Don; Culbert, Brad; Padget, Marty
2003-01-01
The purpose of this study was to evaluate the mechanical characteristics of a new and unique titanium compression anchor with BONE-LOK (Triage Medical, Inc, Irvine, CA) technology for compressive, bi-cortical internal fixation of bone. This device provides fixation through the use of a distal grasping anchor and an adjustable proximal collar that are joined by an axially movable pin and guide wire. The titanium compression anchor, in 2.0-, 2.7-, and 3.5-mm diameters, were compared with cortex screws (Synthes USA, Paoli, PA) of the same diameter and material for pullout strength in 20 lb/cu ft and 30 lb/cu ft solid rigid polyurethane foam; and for compression strength in 20 lb/cu ft foam. Retention strength of the collar was tested independently. The results showed significantly greater pullout strength of the 2.7-mm and 3.5-mm titanium compression anchor as compared with the 2.7-mm and 3.5-mm cortex screws in these test models. Pullout strength of the 2.0-mm titanium compression anchor was not statistically different in comparison with the 2.0-mm cortical screws. Compression strength of the titanium compression anchor was significantly greater than the cortical screws for all diameters tested. These differences represent a distinct advantage with the new device, which warrants further in vivo testing. Collar retention strength testing values were obtained for reference only and have no comparative significance.
Use of silicon oxynitride as a sacrificial material for microelectromechanical devices
Habermehl, Scott D.; Sniegowski, Jeffry J.
2001-01-01
The use of silicon oxynitride (SiO.sub.x N.sub.y) as a sacrificial material for forming a microelectromechanical (MEM) device is disclosed. Whereas conventional sacrificial materials such as silicon dioxide and silicate glasses are compressively strained, the composition of silicon oxynitride can be selected to be either tensile-strained or substantially-stress-free. Thus, silicon oxynitride can be used in combination with conventional sacrificial materials to limit an accumulation of compressive stress in a MEM device; or alternately the MEM device can be formed entirely with silicon oxynitride. Advantages to be gained from the use of silicon oxynitride as a sacrificial material for a MEM device include the formation of polysilicon members that are substantially free from residual stress, thereby improving the reliability of the MEM device; an ability to form the MEM device with a higher degree of complexity and more layers of structural polysilicon than would be possible using conventional compressively-strained sacrificial materials; and improved manufacturability resulting from the elimination of wafer distortion that can arise from an excess of accumulated stress in conventional sacrificial materials. The present invention is useful for forming many different types of MEM devices including accelerometers, sensors, motors, switches, coded locks, and flow-control devices, with or without integrated electronic circuitry.
Factors that influence the tribocharging of pulverulent materials in compressed-air devices
NASA Astrophysics Data System (ADS)
Das, S.; Medles, K.; Mihalcioiu, A.; Beleca, R.; Dragan, C.; Dascalescu, L.
2008-12-01
Tribocharging of pulverulent materials in compressed-air devices is a typical multi-factorial process. This paper aims at demonstrating the interest of using the design of experiments methodology in association with virtual instrumentation for quantifying the effects of various process varaibles and of their interactions, as a prerequisite for the development of new tribocharging devices for industrial applications. The study is focused on the tribocharging of PVC powders in compressed-air devices similar to those employed in electrostatic painting. A classical 2 full-factorial design (3 factors at two levels) was employed for conducting the experiments. The response function was the charge/mass ratio of the material collected in a modified Faraday cage, at the exit of the tribocharging device. The charge/mass ratio was found to increase with the injection pressure and the vortex pressure in the tribocharging device, and to decrease with the increasing of the feed rate. In the present study an in-house design of experiments software was employed for statistical analysis of experimental data and validation of the experimental model.
2012-10-01
Neurologic effects were not measured in this preliminary study. Oxygen therapy has been used as a sole treatment for cyanide toxicity; however, both groups...standardized mechanical chest compressions and were randomly assigned to receive one of 3 intravenous bolus therapies : hydroxocobalamin, epinephrine, or...arterial pressure and pH, decreased blood lactate and cyanide levels, and decreased the use of rescue epinephrine therapy compared with that in the
Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device.
Coogan, Jessica S; Francis, W Loren; Eliason, Travis D; Bredbenner, Todd L; Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A; Nicolella, Daniel P
2016-01-01
Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.
Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device
Coogan, Jessica S.; Francis, W. Loren; Eliason, Travis D.; Bredbenner, Todd L.; Stemper, Brian D.; Yoganandan, Narayan; Pintar, Frank A.; Nicolella, Daniel P.
2016-01-01
Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3–L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3–L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus. PMID:27990418
Rieke, Horst; Rieke, Martin; Gado, Samkon K; Nietert, Paul J; Field, Larry C; Clark, Carlee A; Furse, Cory M; McEvoy, Matthew D
2013-11-01
Quality chest compressions (CC) are the most important factor in successful cardiopulmonary resuscitation. Adjustment of CC based upon an invasive arterial blood pressure (ABP) display would be theoretically beneficial. Additionally, having one compressor present for longer than a 2-min cycle with an ABP display may allow for a learning process to further maximize CC. Accordingly, we tested the hypothesis that CC can be improved with a real-time display of invasively measured blood pressure and with an unchanged, physically fit compressor. A manikin was attached to an ABP display derived from a hemodynamic model responding to parameters of CC rate, depth, and compression-decompression ratio. The area under the blood pressure curve over time (AUC) was used for data analysis. Each participant (N=20) performed 4 CPR sessions: (1) No ABP display, exchange of compressor every 2 min; (2) ABP display, exchange of compressor every 2 min; (3) no ABP display, no exchange of the compressor; (4) ABP display, no exchange of the compressor. Data were analyzed by ANOVA. Significance was set at a p-value<0.05. The average AUC for cycles without ABP display was 5201 mm Hgs (95% confidence interval (CI) of 4804-5597 mm Hgs), and for cycles with ABP display 6110 mm Hgs (95% CI of 5715-6507 mm Hgs) (p<0.0001). The average AUC increase with ABP display for each participant was 20.2±17.4% 95 CI (p<0.0001). Our study confirms the hypothesis that a real-time display of simulated ABP during CPR that responds to participant performance improves achieved and sustained ABP. However, without any real-time visual feedback, even fit compressors demonstrated degradation of CC quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Compression-only CPR training in elementary schools and student attitude toward CPR.
Kitamura, Tetsuhisa; Nishiyama, Chika; Murakami, Yukiko; Yonezawa, Takahiro; Nakai, Shohei; Hamanishi, Masayoshi; Marukawa, Seishiro; Sakamoto, Tetsuya; Iwami, Taku
2016-08-01
Little is known about the effectiveness of systematic cardiopulmonary resuscitation (CPR) training for elementary school children. We introduced systematic training of chest compression-only CPR and automated external defibrillator (AED) use to elementary school students aged 10-12 years at 17 schools. The questionnaire compared student attitudes towards CPR and their knowledge about it before and after CPR training. We also evaluated parent and teacher views about CPR training in school education. The primary outcome was positive attitude, defined as "yes" and "maybe yes" on a 5 point Likert-type scale of student attitudes towards CPR.1 RESULTS: A total of 2047 elementary school students received CPR training. Of them, 1899 (92.8%) responded to the questionnaire regarding their attitude towards CPR before and after the training. Before training, 50.2% answered "yes" and 30.3% answered "maybe yes", to the question: "If someone suddenly collapses in front of you, can you do something such as check response or call emergency?" After training, their answers changed to 75.6% and 18.3% for "yes" and "maybe yes", respectively. Many of the students (72.3%, 271/370) who did not have a positive attitude before CPR training had a positive attitude after the training (P < 0.001). Most students understood how to perform CPR (97.7%) and use an AED (98.5%). Parents (96.2%, 1173/1220) and teachers (98.3%, 56/57) answered that it was "good" and "maybe good" for children to receive the training at elementary schools. Systematic chest compression-only CPR training helped elementary school students to improve their attitude towards CPR. © 2015 Japan Pediatric Society.
Bjørnshave, Katrine; Krogh, Lise Q; Hansen, Svend B; Nebsbjerg, Mette A; Thim, Troels; Løfgren, Bo
2018-02-01
Laypersons often hesitate to perform basic life support (BLS) and use an automated external defibrillator (AED) because of self-perceived lack of knowledge and skills. Training may reduce the barrier to intervene. Reduced training time and costs may allow training of more laypersons. The aim of this study was to compare BLS/AED skills' acquisition and self-evaluated BLS/AED skills after instructor-led training with a two-stage versus a four-stage teaching technique. Laypersons were randomized to either two-stage or four-stage teaching technique courses. Immediately after training, the participants were tested in a simulated cardiac arrest scenario to assess their BLS/AED skills. Skills were assessed using the European Resuscitation Council BLS/AED assessment form. The primary endpoint was passing the test (17 of 17 skills adequately performed). A prespecified noninferiority margin of 20% was used. The two-stage teaching technique (n=72, pass rate 57%) was noninferior to the four-stage technique (n=70, pass rate 59%), with a difference in pass rates of -2%; 95% confidence interval: -18 to 15%. Neither were there significant differences between the two-stage and four-stage groups in the chest compression rate (114±12 vs. 115±14/min), chest compression depth (47±9 vs. 48±9 mm) and number of sufficient rescue breaths between compression cycles (1.7±0.5 vs. 1.6±0.7). In both groups, all participants believed that their training had improved their skills. Teaching laypersons BLS/AED using the two-stage teaching technique was noninferior to the four-stage teaching technique, although the pass rate was -2% (95% confidence interval: -18 to 15%) lower with the two-stage teaching technique.
Chekan, Edward; Whelan, Richard L
2014-01-01
The introduction of both new surgical devices and reengineered existing devices leads to modifications in the way traditional tasks are carried out and allows for the development of new surgical techniques. Each new device has benefits and limitations in regards to tissue interactions that, if known, allow for optimal use. However, most surgeons are unaware of these attributes and, therefore, new device introduction creates a "knowledge gap" that is potentially dangerous. The goal of this review is to present a framework for the study of device- tissue interactions and to initiate the process of "filling in" the knowledge gap via the available literature. Surgical staplers, which are continually being developed, are the focus of this piece. The integrity of the staple line, which depends on adequate tissue compression, is the primary factor in creating a stable anastomosis. This review focuses on published studies that evaluated the creation of stable anastomoses in bariatric, thoracic, and colorectal procedures. Understanding how staplers interact with target tissues is key to improving patient outcomes. It is clear from this review that each tissue type presents unique challenges. The thickness of each tissue varies as do the intrinsic biomechanical properties that determine the ideal compressive force and prefiring compression time for each tissue type. The correct staple height will vary depending on these tissue-specific properties and the tissue pathology. These studies reinforce the universal theme that compression, staple height, tissue thickness, tissue compressibility, and tissue type must all be considered by the surgeon prior to choosing a stapler and cartridge. The surgeon's experience, therefore, is a critical factor. Educational programs need to be established to inform and update surgeons on the characteristics of each stapler. It is hoped that the framework presented in this review will facilitate this process.
Cachia, Victor V; Culbert, Brad; Warren, Chris; Oka, Richard; Mahar, Andrew
2003-01-01
The purpose of this study was to evaluate the structural and mechanical characteristics of a new and unique titanium cortical-cancellous helical compression anchor with BONE-LOK (Triage Medical, Inc., Irvine, CA) technology for compressive internal fixation of fractures and osteotomies. This device provides fixation through the use of a distal helical anchor and a proximal retentive collar that are united by an axially movable pin (U.S. and international patents issued and pending). The helical compression anchor (2.7-mm diameter) was compared with 3.0-mm diameter titanium cancellous screws (Synthes, Paoli, PA) for pullout strength and compression in 7# and 12# synthetic rigid polyurethane foam (simulated bone matrix), and for 3-point bending stiffness. The following results (mean +/- standard deviation) were obtained: foam block pullout strength in 12# foam: 2.7-mm helical compression anchor 70 +/- 2.0 N and 3.0-mm titanium cancellous screws 37 +/- 11 N; in 7# foam: 2.7-mm helical compression anchor 33 +/- 3 N and 3.0-mm titanium cancellous screws 31 +/- 12 N. Three-point bending stiffness, 2.7-mm helical compression anchor 988 +/- 68 N/mm and 3.0-mm titanium cancellous screws 845 +/- 88 N/mm. Compression strength testing in 12# foam: 2.7-mm helical compression anchor 70.8 +/- 4.8 N and 3.0-mm titanium cancellous screws 23.0 +/- 3.1 N, in 7# foam: 2.7-mm helical compression anchor 42.6 +/- 3.2 N and 3.0-mm titanium cancellous screws 10.4 +/- 0.9 N. Results showed greater pullout strength, 3-point bending stiffness, and compression strength for the 2.7-mm helical compression anchor as compared with the 3.0-mm titanium cancellous screws in these testing models. This difference represents a distinct advantage in the new device that warrants further in vivo testing.
Gold-based electrical interconnections for microelectronic devices
Peterson, Kenneth A.; Garrett, Stephen E.; Reber, Cathleen A.; Watson, Robert D.
2002-01-01
A method of making an electrical interconnection from a microelectronic device to a package, comprising ball or wedge compression bonding a gold-based conductor directly to a silicon surface, such as a polysilicon bonding pad in a MEMS or IMEMS device, without using layers of aluminum or titanium disposed in-between the conductor and the silicon surface. After compression bonding, optional heating of the bond above 363 C. allows formation of a liquid gold-silicon eutectic phase containing approximately 3% (by weight) silicon, which significantly improves the bond strength by reforming and enhancing the initial compression bond. The same process can be used for improving the bond strength of Au--Ge bonds by forming a liquid Au-12Ge eutectic phase.
Roth, Robert Paul; Hahn, David C.; Scaringe, Robert P.
2015-12-08
A device and method are provided to improve performance of a vapor compression system using a retrofittable control board to start up the vapor compression system with the evaporator blower initially set to a high speed. A baseline evaporator operating temperature with the evaporator blower operating at the high speed is recorded, and then the device detects if a predetermined acceptable change in evaporator temperature has occurred. The evaporator blower speed is reduced from the initially set high speed as long as there is only a negligible change in the measured evaporator temperature and therefore a negligible difference in the compressor's power consumption so as to obtain a net increase in the Coefficient of Performance.
Cardiovascular causes of airway compression.
Kussman, Barry D; Geva, Tal; McGowan, Francis X
2004-01-01
Compression of the paediatric airway is a relatively common and often unrecognized complication of congenital cardiac and aortic arch anomalies. Airway obstruction may be the result of an anomalous relationship between the tracheobronchial tree and vascular structures (producing a vascular ring) or the result of extrinsic compression caused by dilated pulmonary arteries, left atrial enlargement, massive cardiomegaly, or intraluminal bronchial obstruction. A high index of suspicion of mechanical airway compression should be maintained in infants and children with recurrent respiratory difficulties, stridor, wheezing, dysphagia, or apnoea unexplained by other causes. Prompt diagnosis is required to avoid death and minimize airway damage. In addition to plain chest radiography and echocardiography, diagnostic investigations may consist of barium oesophagography, magnetic resonance imaging (MRI), computed tomography, cardiac catheterization and bronchoscopy. The most important recent advance is MRI, which can produce high quality three-dimensional reconstruction of all anatomic elements allowing for precise anatomic delineation and improved surgical planning. Anaesthetic technique will depend on the type of vascular ring and the presence of any congenital heart disease or intrinsic lesions of the tracheobronchial tree. Vascular rings may be repaired through a conventional posterolateral thoracotomy, or utilizing video-assisted thoracoscopic surgery (VATS) or robotic endoscopic surgery. Persistent airway obstruction following surgical repair may be due to residual compression, secondary airway wall instability (malacia), or intrinsic lesions of the airway. Simultaneous repair of cardiac defects and vascular tracheobronchial compression carries a higher risk of morbidity and mortality.
Spelten, Oliver; Warnecke, Tobias; Wetsch, Wolfgang A; Schier, Robert; Böttiger, Bernd W; Hinkelbein, Jochen
2016-08-01
High-quality cardiopulmonary resuscitation (CPR) by laypersons is a key determinant of both outcome and survival for out-of-hospital cardiac arrest. Dispatcher-assisted CPR (telephone-CPR, T-CPR) increases the frequency and correctness of bystander-CPR but results in prolonged time to first chest compressions. However, it remains unclear whether instructions for rescue ventilation and/or chest compressions should be recommended for dispatcher-assisted CPR. The aim of this study was to evaluate both principles of T-CPR with respect to CPR quality. Randomised controlled single-blinded manikin trial. University Hospital of Cologne, Germany, 1 July 2012 to 30 September 2012. Sixty laypersons between 18 and 65 years. Medically educated individuals, medical professionals and pregnant women were excluded. Participants were asked to resuscitate a manikin and were randomised into three groups: not dispatcher-assisted (uninstructed) CPR (group 1; U-CPR; n = 20), dispatcher-assisted compression-only CPR (group 2; DACO-CPR; n = 19) and full dispatcher-assisted CPR with rescue ventilation (group 3; DAF-CPR; n = 19). Specific parameters of CPR quality [i.e. no-flow-time (NFT) as well as compression and ventilation parameters] were analysed. To compare different groups we used Student's t test and P less than 0.05 was considered significant. Initial NFT was lowest in the DACO-CPR group (mean 21.3 ± 14.4%), followed by dispatcher-assisted full CPR (mean 49.1 ± 8.5%) and by unassisted CPR (mean 55.0 ± 12.9%). Initial NFT covering the time of instruction was lower in DACO-CPR (12.1 ± 5.4%) as compared to dispatcher-assisted full CPR (20.7 ± 8.1%). Compression depth was similar in all three groups: 40.6 ± 13.0 mm (unassisted CPR), 41.0 ± 12.2 mm (DACO-CPR) and 38.8 ± 15.8 mm (dispatcher-assisted full CPR). Average compression frequency was highest in the DACO-CPR group (65.2 ± 22.4 min) compared with the unassisted CPR group (35.6 ± 24.2 min) and the dispatcher-assisted full CPR group (44.5 ± 10.8 min). Correct rescue ventilation was given in 3.1 ± 11.1% (unassisted CPR) and 1.6 ± 16.1% (dispatcher-assisted full CPR) of all ventilation attempts. Best quality of CPR was achieved by DACO-CPR because of superior compression frequencies and reduced NFT. In contrast, the full dispatcher-assisted CPR with a longer initial instructing phase (initial NFT) did not result in enhanced CPR quality or an optimised compression depth.
Feo, Claudio F; Ginesu, Giorgio C; Bellini, Alessandro; Cherchi, Giuseppe; Scanu, Antonio M; Cossu, Maria Laura; Fancellu, Alessandro; Porcu, Alberto
2017-09-01
Totally implantable venous access devices (TIVADs) represent a convenient way for the administration of medications or nutrients. Traditionally, chest ports have been positioned by surgeons in the operating room, however there has been a transition over the years to port insertion by interventional radiologists in the radiology suite. The optimal method for chest port placement is still under debate. Data on all adult patients undergoing isolated chest port placement at our institution in a 12-year period were retrospectively reviewed. The aim of this cohort study was to compare cost and morbidity for chest port insertion in two different settings: outpatient clinic and operating room. Between 2003 and 2015 a total of 527 chest ports were placed in adult patients. Of them, 262 procedures were performed in the operating room and 265 procedures were undertaken in the outpatient clinic. Patient characteristics were similar and there was no significant difference in early (<30 days, p = 0.54) and late complications (30-120 days, p = 0.53). The average charge for placement of a chest port was 1270 Euros in the operating room versus 620 Euros in the outpatient clinic. Our results suggest that chest ports can be safely placed in most patients under local anesthesia in the office setting without fluoroscopy or ultrasound guidance. Future randomized controlled studies may evaluate if surgeons or interventional radiologists should routinely perform these procedures in a dedicated office setting and reserve more sophisticated facilities only for patients at high risk of technical failure.
Gudejko, Michael D; Gebhardt, Brian R; Zahedi, Farhad; Jain, Ankit; Breeze, Janis L; Lawrence, Matthew R; Shernan, Stanton K; Kapur, Navin K; Kiernan, Michael S; Couper, Greg; Cobey, Frederick C
2018-06-05
Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of severe RVF. Post-chest closure CVP and post-chest closure PAPi discriminated severe from nonsevere RVF better than other variables measured, each with an area under the curve of 0.75 (95% CI, 0.64-0.86). Post-chest closure values of CVP and PAPi were significantly associated with severe RVF. Echocardiographic assessment of RV function post-CPB was weakly associated with severe RVF.
Hildebrand, Richard J.; Wozniak, John J.
2001-01-01
A compressed gas storage cell interconnecting manifold including a thermally activated pressure relief device, a manual safety shut-off valve, and a port for connecting the compressed gas storage cells to a motor vehicle power source and to a refueling adapter. The manifold is mechanically and pneumatically connected to a compressed gas storage cell by a bolt including a gas passage therein.
Næss, Pål Aksel; Engeseth, Kristian; Grøtta, Ole; Andersen, Geir Øystein; Gaarder, Christine
2016-05-29
Life-threatening bleeding caused by liver injury due to chest compressions is a rare complication in otherwise successful cardiopulmonary resuscitation. Surgical intervention has been suggested to achieve bleeding control; however, reported mortality is high. In this report, we present a brief literature review and a case report in which use of a less invasive strategy was followed by an uneventful recovery. A 37-year-old white woman was admitted after out-of-hospital cardiac arrest. Bystander cardiopulmonary resuscitation was immediately performed, followed by advanced cardiopulmonary resuscitation that included tracheal intubation, mechanical chest compressions, and external defibrillation with return of spontaneous circulation. Upon hospital admission, the patient's blood pressure was 94/45 mmHg and her heart rate was 110 beats per minute. Her electrocardiogram showed no signs of ST-segment elevations or Q-wave development. Coronary angiography revealed a proximal thrombotic occlusion of the left anterior descending coronary artery. Successful recanalization, after thrombus aspiration and balloon dilation followed by stent implant, was verified with normalized anterograde flow. Immediately after the patient's arrival in the intensive cardiac care unit, a drop in her blood pressure to 60/30 mmHg and a hemoglobin concentration of 4.5 g/dl were noticed. Transfusion was started, and bedside abdominal ultrasound examination revealed free intraperitoneal fluid. Computed tomography of the abdomen revealed liver injury with active extravasation from the cranial surface of the right lobe and a massive hemoperitoneum. The patient was coagulopathic and acidotic with a body temperature of 33.5 °C. A minimally invasive treatment strategy, including angiography and selective trans-catheter arterial embolization, were performed in combination with percutaneous evacuation of 4.5 L of intraperitoneal blood. After completion of these procedures, the patient was hemodynamically stable. She was weaned off mechanical ventilation 2 days later and made an uneventful recovery. She was discharged to a local hospital on day 13 without neurological disability. Although rare, bleeding caused by liver injury due to chest compressions can be life-threatening after successful cardiopulmonary resuscitation. Reported mortality is high after surgical intervention, and patients may benefit from less invasive treatment strategies such as those presented in this case report.
Spool-like stent for the open sternum after cardiac operations.
Satoh, H; Sakai, K; Koyama, M; Matsuda, H
1997-02-01
Severe edematous heart after a cardiac operation is impossible to treat if there is compression of the heart due to the sternum. In these patients delayed sternal closure may be a useful procedure until the heart decreases in size. We devised a spool-like stent for the open sternum to maintain the optimal cardiac space for the severely edematous heart and to fix the chest wall to allow for management while the sternum is open.
Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey
2018-01-01
To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio ( n =57); or (2) verbal dispatcher assistance ( n =52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P >0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P <0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min -1 ) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.
Observer detection of image degradation caused by irreversible data compression processes
NASA Astrophysics Data System (ADS)
Chen, Ji; Flynn, Michael J.; Gross, Barry; Spizarny, David
1991-05-01
Irreversible data compression methods have been proposed to reduce the data storage and communication requirements of digital imaging systems. In general, the error produced by compression increases as an algorithm''s compression ratio is increased. We have studied the relationship between compression ratios and the detection of induced error using radiologic observers. The nature of the errors was characterized by calculating the power spectrum of the difference image. In contrast with studies designed to test whether detected errors alter diagnostic decisions, this study was designed to test whether observers could detect the induced error. A paired-film observer study was designed to test whether induced errors were detected. The study was conducted with chest radiographs selected and ranked for subtle evidence of interstitial disease, pulmonary nodules, or pneumothoraces. Images were digitized at 86 microns (4K X 5K) and 2K X 2K regions were extracted. A full-frame discrete cosine transform method was used to compress images at ratios varying between 6:1 and 60:1. The decompressed images were reprinted next to the original images in a randomized order with a laser film printer. The use of a film digitizer and a film printer which can reproduce all of the contrast and detail in the original radiograph makes the results of this study insensitive to instrument performance and primarily dependent on radiographic image quality. The results of this study define conditions for which errors associated with irreversible compression cannot be detected by radiologic observers. The results indicate that an observer can detect the errors introduced by this compression algorithm for compression ratios of 10:1 (1.2 bits/pixel) or higher.
Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey
2018-01-01
BACKGROUND: To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. METHODS: It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio (n=57); or (2) verbal dispatcher assistance (n=52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. RESULTS: There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P>0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P<0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min-1) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). CONCLUSION: When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.
Broeders, Mireille J M; Ten Voorde, Marloes; Veldkamp, Wouter J H; van Engen, Ruben E; van Landsveld-Verhoeven, Cary; 't Jong-Gunneman, Machteld N L; de Win, Jos; Greve, Kitty Droogh-de; Paap, Ellen; den Heeten, Gerard J
2015-03-01
To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. There was no difference in pain experience between both paddles (mean difference NRS: 0.08 ± 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 ± 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC views.
Tweed, M; Tweed, C; Perkins, G D
2001-11-01
External chest compression (ECC) efficacy is influenced by factors including the surface supporting the patient. Air-filled support surfaces are deflated for cardiopulmonary resuscitation, with little evidence to substantiate this. We investigated the effect that differing support surfaces had on ECC efficacy using a CPR manikin model. Four participants carried out four cycles of ECC with an assistant ventilating. The subjects were blinded to the seven support surfaces and the order was randomised. For each participant/surface combination, ECC variables and the participants' perceptions were measured. Participants produced effective ECC with the manikin on the floor (mean proportion correct, 94.5%; mean depth, 42.5 mm). Compared with the floor: the proportion of correct ECC was less for the overlay inflated (P<0.05); the depth of ECC was less effective (30-37 mm) for the overlay inflated/deflated and low-air-loss inflated and foam mattresses (P<0.05). The foam mattress, overlay inflated/deflated, and low-air-loss inflated were perceived as being less stable and as having reduced ECC efficacy compared with the floor. There was no difference or agreement, regarding subjects' perceptions or ECC variables, between the support surfaces or between inflated/deflated air-filled support surfaces. The efficacy of ECC is affected by the support surfaces. There seems little evidence to substantiate deflating all air-filled support surfaces for CPR.
Usefulness of emergency ultrasound in nontraumatic cardiac arrest.
Volpicelli, Giovanni
2011-02-01
Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.
Koch Hansen, Lars; Mohammed, Anna; Pedersen, Magnus; Folkestad, Lars; Brodersen, Jacob; Hey, Thomas; Lyhne Christensen, Nicolaj; Carter-Storch, Rasmus; Bendix, Kristoffer; Hansen, Morten R; Brabrand, Mikkel
2016-12-01
Reducing hands-off time during cardiopulmonary resuscitation (CPR) is believed to increase survival after cardiac arrests because of the sustaining of organ perfusion. The aim of our study was to investigate whether charging the defibrillator before rhythm analyses and shock delivery significantly reduced hands-off time compared with the European Resuscitation Council (ERC) 2010 CPR guideline algorithm in full-scale cardiac arrest scenarios. The study was designed as a full-scale cardiac arrest simulation study including administration of drugs. Participants were randomized into using the Stop-Only-While-Shocking (SOWS) algorithm or the ERC2010 algorithm. In SOWS, chest compressions were only interrupted for a post-charging rhythm analysis and immediate shock delivery. A Resusci Anne HLR-D manikin and a LIFEPACK 20 defibrillator were used. The manikin recorded time and chest compressions. Sample size was calculated with an α of 0.05 and 80% power showed that we should test four scenarios with each algorithm. Twenty-nine physicians participated in 11 scenarios. Hands-off time was significantly reduced 17% using the SOWS algorithm compared with ERC2010 [22.1% (SD 2.3) hands-off time vs. 26.6% (SD 4.8); P<0.05]. In full-scale cardiac arrest simulations, a minor change consisting of charging the defibrillator before rhythm check reduces hands-off time by 17% compared with ERC2010 guidelines.
Grenier, Etienne; Gehin, Claudine; Lun, Bertrand; McAdams, Eric
2013-01-01
This paper presents a preliminary study to demonstrate the instantaneous local effect of compression stocking (Class 2) on skin microcirculatory activity. The measurement needs to be carefully performed as the sensor is placed under the garment. To assess the local effect of compression stockings, we use the ambulatory device Hematron located on the calf under the garment. Skin microcirculatory activity is assessed through the skin's effective thermal conductivity measurement. A specific housing for the sensor has been designed to avoid excessive pressure induced by the sensor when squeezed by stockings. The experiment, conducted on ten healthy subjects, comprised two stages: without and with compression stockings. Skin effective thermal conductivity was recorded at three successive positions (supine, sitting and standing). Significant improvement in skin microcirculatory activity was recorded by the Hematron device for the three positions. We have also demonstrated that Hematron sensor can be used under compression stockings.
Practical use of bone scan in patients with an osteoporotic vertebral compression fracture.
Jun, Deuk Soo; An, Byoung Keun; Yu, Chang Hun; Hwang, Kyung Hoon; Paik, Je Won
2015-02-01
Rib fractures are one of main causes of chest or flank pain when related to an osteoporotic vertebral compression fracture (OVCF). The authors investigated the incidence and risk factors of rib fracture in 284 patients with OVCF using bone scans and evaluated the feasibility as to whether bone scans could be utilized as a useful screening tool. Hot uptake lesions on ribs were found in 122 cases (43.0%). The factors analyzed were age, sex, number and locations of fractured vertebrae, BMD, and compression rates as determined using initial radiography. However, no statistical significances were found. In 16 cases (5.6%), there were concurrent multiple fractures of both the thoracic and lumbar spines not detected by single site MRI. Sixty cases (21.1%) of OVCF with the a compression rate of less than 15% could not be identified definitely by initial plain radiography, but were confirmed by bone scans. It is concluded that a bone scan has outstanding ability for the screening of rib fractures associated with OVCF. Non-adjacent multiple fractures in both thoracic and lumbar spines and fractures not identified definitely by plain radiography were detected on bone scans, which provided a means for determining management strategies and predicting prognosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, T; Kang, S; Kim, D
Purpose: The aim of this study is to develop the abdominal compression device which could control pressure level according to the abdominal respiratory motion and evaluate its feasibility. Methods: In this study, we focused on developing the abdominal compression device which could control pressure level at any point of time so the developed device is possible to use a variety of purpose (gating technique or respiratory training system) while maintaining the merit of the existing commercial device. The compression device (air pad form) was designed to be able to compress the front and side of abdomen and the pressure levelmore » of the abdomen is controlled by air flow. Pressure level of abdomen (air flow) was determined using correlation data between external abdominal motion and respiratory volume signal measured by spirometer. In order to verify the feasibility of the device, it was necessary to confirm the correlation between the abdominal respiratory motion and respiratory volume signal and cooperation with respiratory training system also checked. Results: In the previous study, we could find that the correlation coefficient ratio between diaphragm and respiratory volume signal measured by spirometer was 0.95. In this study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion measured by belt-transducer (correlation coefficient ratio was 0.92) and used the correlated respiratory volume data as an abdominal pressure level. It was possible to control the pressure level with negligible time delay and respiratory volume data based guiding waveforms could be properly inserted into the respiratory training system. Conclusion: Through this feasibility study, we confirmed the correlation between the respiratory volume signal and the external abdominal motion. Also initial assessment of the device and its compatibility with the respiratory training system were verified. Further study on application in respiratory gated therapy and respiratory training system will be investigated. This work was supported by Radiation Technology R and D program (No. 2013M2A2A7043498)and Basic Atomic Energy Research Institute (BAERI)(No. NRF-2009-0078390) through the National Research Foundation of Korea funded by the Ministry of Science, ICT and Future Planning.« less
NASA Technical Reports Server (NTRS)
Wesselski, Clarence J. (Inventor); Nagy, Kornel (Inventor)
1992-01-01
A latching device is disclosed which is lever operated sequentially to actuate a set of collet fingers to provide a radial expansion and to actuate a force mechanism to provide a compressive gripping force for attaching first and second devices to one another. The latching device includes a body member having elongated collet fingers which, in a deactuated condition, is insertable through bores on the first and second devices so that gripping terminal portions on the collet fingers are proximate to the end of the bore of the first device while a spring assembly on the body member is located proximate to the outer surface of a second device. A lever is rotatable through 90 deg to move a latching rod to sequentially actuate and expand collet fingers and to actuate the spring assembly by compressing it. During the first 30 deg of movement of the lever, the collet fingers are actuated by the latching rod to provide a radial expansion and during the last 60 deg of movement of the lever, the spring assembly acts as a force mechanism and is actuated to develop a compressive latching force on the devices. The latching rod and lever are connected by a camming mechanism. The amount of spring force in the spring assembly can be adjusted; the body member can be permanently attached by a telescoping assembly to one of the devices; and the structure can be used as a pulling device for removing annular bearings or the like from blind bores.
A Comparative Study of Compression Video Technology.
ERIC Educational Resources Information Center
Keller, Chris A.; And Others
The purpose of this study was to provide an overview of compression devices used to increase the cost effectiveness of teleconferences by reducing satellite bandwidth requirements for the transmission of television pictures and accompanying audio signals. The main body of the report describes the comparison study of compression rates and their…
Multiple Compressions in the Middle Energy Plasma Focus Device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yousefi, H. R.; Ejiri, Y.; Ito, H.
This paper reports some of the results that are aimed to investigate the neutron emission from the middle energy Mather-type plasma focus. These results indicated that with increase the pressure, compression time is increase but there is not any direct relation between the compression time and neutron yield. Also it seems that multiple compression regimes is occurred in low pressure and single compression is appeared at higher pressure where is the favorable to neutron production.
Cao, Xin; He, Jin; Li, Huan; Kang, Liping; He, Xuexia; Sun, Jie; Jiang, Ruibing; Xu, Hua; Lei, Zhibin; Liu, Zong-Huai
2018-05-30
Compared with other flexible energy-storage devices, the design and construction of the compressible energy-storage devices face more difficulty because they must accommodate large strain and shape deformations. In the present work, CoNi 2 S 4 nanoparticles/3D porous carbon nanotube (CNT) sponge cathode with highly compressible property and excellent capacitance is prepared by electrodepositing CoNi 2 S 4 on CNT sponge, in which CoNi 2 S 4 nanoparticles with size among 10-15 nm are uniformly anchored on CNT, causing the cathode to show a high compression property and gives high specific capacitance of 1530 F g -1 . Meanwhile, Fe 2 O 3 /CNT sponge anode with specific capacitance of 460 F g -1 in a prolonged voltage window is also prepared by electrodepositing Fe 2 O 3 nanosheets on CNT sponge. An asymmetric supercapacitor (CoNi 2 S 4 /CNT//Fe 2 O 3 /CNT) is assembled by using CoNi 2 S 4 /CNT sponge as positive electrode and Fe 2 O 3 /CNT sponge as negative electrode in 2 m KOH solution. It exhibits excellent energy density of up to 50 Wh kg -1 at a power density of 847 W kg -1 and excellent cycling stability at high compression. Even at a strain of 85%, about 75% of the initial capacitance is retained after 10 000 consecutive cycles. The CoNi 2 S 4 /CNT//Fe 2 O 3 /CNT device is a promising candidate for flexible energy devices due to its excellent compressibility and high energy density. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Charbonney, Emmanuel; Delisle, Stéphane; Savary, Dominique; Bronchti, Gilles; Rigollot, Marceau; Drouet, Adrien; Badat, Bilal; Ouellet, Paul; Gosselin, Patrice; Mercat, Alain; Brochard, Laurent; Richard, Jean-Christophe M
2018-04-01
Studying ventilation and intrathoracic pressure (ITP) induced by chest compressions (CC) during Cardio Pulmonary Resuscitation is challenging and important aspects such as airway closure have been mostly ignored. We hypothesized that Thiel Embalmed Cadavers could constitute an appropriate model. We assessed respiratory mechanics and ITP during CC in 11 cadavers, and we compared it to measurements obtained in 9 out-of-hospital cardiac arrest patients and to predicted values from a bench model. An oesophageal catheter was inserted to assess chest wall compliance, and ITP variation (ΔITP). Airway pressure variation (ΔPaw) at airway opening and ΔITP generated by CC were measured at decremental positive end expiratory pressure (PEEP) to test its impact on flow and ΔPaw. The patient's data were derived from flow and airway pressure captured via the ventilator during resuscitation. Resistance and Compliance of the respiratory system were comparable to those of the out-of-hospital cardiac arrest patients (C RS TEC 42 ± 12 vs C RS PAT 37.3 ± 10.9 mL/cmH 2 O and Res TEC 17.5 ± 7.5 vs Res PAT 20.2 ± 5.3 cmH 2 O/L/sec), and remained stable over time. During CC, ΔITP varied from 32 ± 12 cmH 2 O to 69 ± 14 cmH 2 O with manual and automatic CC respectively. Transmission of ΔITP at the airway opening was significantly affected by PEEP, suggesting dynamic small airway closure at low lung volumes. This phenomenon was similarly observed in patients. Respiratory mechanics and dynamic pressures during CC of cadavers behave as predicted by a theoretical model and similarly to patients. The Thiel model is a suitable to assess ITP variations induced by ventilation during CC. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakamura, Katsumasa; Shioyama, Yoshiyuki; Nomoto, Satoru
2007-05-01
Purpose: The voluntary breath-hold (BH) technique is a simple method to control the respiration-related motion of a tumor during irradiation. However, the abdominal and chest wall position may not be accurately reproduced using the BH technique. The purpose of this study was to examine whether visual feedback can reduce the fluctuation in wall motion during BH using a new respiratory monitoring device. Methods and Materials: We developed a laser-based BH monitoring and visual feedback system. For this study, five healthy volunteers were enrolled. The volunteers, practicing abdominal breathing, performed shallow end-expiration BH (SEBH), shallow end-inspiration BH (SIBH), and deep end-inspirationmore » BH (DIBH) with or without visual feedback. The abdominal and chest wall positions were measured at 80-ms intervals during BHs. Results: The fluctuation in the chest wall position was smaller than that of the abdominal wall position. The reproducibility of the wall position was improved by visual feedback. With a monitoring device, visual feedback reduced the mean deviation of the abdominal wall from 2.1 {+-} 1.3 mm to 1.5 {+-} 0.5 mm, 2.5 {+-} 1.9 mm to 1.1 {+-} 0.4 mm, and 6.6 {+-} 2.4 mm to 2.6 {+-} 1.4 mm in SEBH, SIBH, and DIBH, respectively. Conclusions: Volunteers can perform the BH maneuver in a highly reproducible fashion when informed about the position of the wall, although in the case of DIBH, the deviation in the wall position remained substantial.« less
Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng
2015-01-01
The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.
Oscillating devices for airway clearance in people with cystic fibrosis.
Morrison, Lisa; Innes, Stephanie
2017-05-04
Chest physiotherapy is widely prescribed to assist the clearance of airway secretions in people with cystic fibrosis. Oscillating devices generate intra- or extra-thoracic oscillations orally or external to the chest wall. Internally they create variable resistances within the airways, generating controlled oscillating positive pressure which mobilises mucus. Extra-thoracic oscillations are generated by forces outside the respiratory system, e.g. high frequency chest wall oscillation. This is an update of a previously published review. To identify whether oscillatory devices, oral or chest wall, are effective for mucociliary clearance and whether they are equivalent or superior to other forms of airway clearance in the successful management of secretions in people with cystic fibrosis. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches and hand searches of relevant journals and abstract books of conference proceedings. Latest search of the Cystic Fibrosis Trials Register: 27 April 2017.In addition we searched the trials databases ClinicalTrials.gov and the WHO International Clinical Trials Registry Platform. Latest search of trials databases: 26 April 2017. Randomised controlled studies and controlled clinical studies of oscillating devices compared with any other form of physiotherapy in people with cystic fibrosis. Single-treatment interventions (therapy technique used only once in the comparison) were excluded. Two authors independently applied the inclusion criteria to publications and assessed the quality of the included studies. The searches identified 76 studies (302 references); 35 studies (total of 1138 participants) met the inclusion criteria. Studies varied in duration from up to one week to one year; 20 of the studies were cross-over in design. The studies also varied in type of intervention and the outcomes measured, data were not published in sufficient detail in most of these studies, so meta-analysis was limited. Few studies were considered to have a low risk of bias in any domain. It is not possible to blind participants and clinicians to physiotherapy interventions, but 11 studies did blind the outcome assessors.Forced expiratory volume in one second was the most frequently measured outcome. One long-term study (seven months) compared oscillatory devices with either conventional physiotherapy or breathing techniques and found statistically significant differences in some lung function parameters in favour of oscillating devices. One study identified an increase in frequency of exacerbations requiring antibiotics whilst using high frequency chest wall oscillation when compared to positive expiratory pressure. There were some small but significant changes in secondary outcome variables such as sputum volume or weight, but not wholly in favour of oscillating devices. Participant satisfaction was reported in 15 studies but this was not specifically in favour of an oscillating device, as some participants preferred breathing techniques or techniques used prior to the study interventions. The results for the remaining outcome measures were not examined or reported in sufficient detail to provide any high level evidence. There was no clear evidence that oscillation was a more or less effective intervention overall than other forms of physiotherapy; furthermore there was no evidence that one device is superior to another. The findings from one study showing an increase in frequency of exacerbations requiring antibiotics whilst using an oscillating device compared to positive expiratory pressure may have significant resource implications. More adequately-powered long-term randomised controlled trials are necessary and outcomes measured should include frequency of exacerbations, individual preference, adherence to therapy and general satisfaction with treatment. Increased adherence to therapy may then lead to improvements in other parameters, such as exercise tolerance and respiratory function. Additional evidence is needed to evaluate whether oscillating devices combined with other forms of airway clearance is efficacious in people with cystic fibrosis.There may also be a requirement to consider the cost implication of devices over other forms of equally advantageous airway clearance techniques. Using the GRADE method to assess the quality of the evidence, we judged this to be low or very low quality, which suggests that further research is very likely to have an impact on confidence in any estimate of effect generated by future interventions.
NASA Technical Reports Server (NTRS)
Howard, W. H.; Young, D. R.
1972-01-01
Device applies compressive force to bone to minimize loss of bone calcium during weightlessness or bedrest. Force is applied through weights, or hydraulic, pneumatic or electrically actuated devices. Device is lightweight and easy to maintain and operate.
Desai, Sanjay; Mitra, Amit; Arkans, Ed; Singh, Tej M
2018-05-01
Delays in arteriovenous fistula maturation can cause care delays and increased costs. Increased distention pressure and intermittent wall shear stress may dilate veins based on prior research. Early use of non-invasive devices may help assist clinical arteriovenous fistula dilation. This was an Institutional Review Board approved study. After arteriovenous fistula creation, a novel, intermittent pneumatic compression device (Fist Assist ® ) was applied 15 cm proximal to arteriovenous fistula enabling 60 mmHg of cyclic compression for 6 h daily for 30 days. Among the patients who completed 1 month follow-up, 30 (n = 30) arteriovenous fistula patients were in the study arm to test vein dilation with Fist Assist. Controls (n = 16) used a sham device. Vein size was measured and recorded at baseline and after 30 days by duplex measurement. Clinical results (percentage increase) were recorded and tested for significance. No patients experienced thrombosis or adverse effects. Patient compliance and satisfaction was high. After 1 month, the mean percentage increase in vein diameter in the Fist Assist treatment group was significantly larger (p = 0.026) than controls in the first 5 mm segment of the fistula after the anastomosis. All fistulas treated with Fist Assist are still functional with no reported thrombosis or extravasations. Early application of an intermittent pneumatic compression device may assist in arteriovenous fistula dilation and are safe. Non-invasive devices like Fist Assist may have clinical utility to help fistulae development and decrease costs as they may eventually assist maturation.
Berliner, Jonathan L; Ortiz, Philippe A; Lee, Yuo-Yu; Miller, Theodore T; Westrich, Geoffrey H
2018-01-01
Improvements in device design have allowed for portable pneumatic compression devices (PPCDs). However, portability results in smaller pumps that move less blood. Additionally, although patients often stand when wearing PPCDs, few studies have evaluated the hemodynamic effects of PCDs while standing. A crossover study was performed to compare a PPCD (ActiveCare+S.F.T.; Medical Compression Systems, Or Akiva, Israel) to a stationary pneumatic compression device (SPCD) (VenaFlow; DJO Global, Carlsbad, CA) on hemodynamics in supine and standing positions among 2 cohorts composed of 10 controls and 10 total hip arthroplasty patients. Differences in baseline peak venous velocity (PVV), PVV with each PCD, and delta PVV with each PCD were assessed. A multivariate analysis was performed to examine differences between cohorts, devices, and position. In both positions, the SPCD demonstrated a larger change in PVV when compared to the PPCD (P < .001). The total hip arthroplasty group had a greater delta PVV while standing when considering both PCDs together (P < .001). When considering both cohorts, delta PVV was greater while standing, only when the SPCD was used (P < .001). There was no difference between standing and supine positions when the PPCD was used. The SPCD demonstrated a greater capacity to increase PPV in the supine and standing positions. The SPCD generated greater values of PVV and delta PVV in the standing position. Although these results demonstrate a difference between devices, it is important to establish the PVV necessary to prevent VTE before one is considered more effective. Copyright © 2017 Elsevier Inc. All rights reserved.
Pulsed Dose Delivery of Oxygen in Mechanically Ventilated Pigs with Acute Lung Injury
2013-03-01
collapse or arrhythmia were encountered after administration of oleic acid, chest compressions, electrical defibrillation , and epinephrine (0.1-1 mg/kg...endotracheal tube to continuously measure the oxygen content of the gas in the circuit. We designed the study as a crossover trial, so each animal served as... designed to prove that a pulsed dose delivery system would be a better method of oxygen delivery, it is interesting to note that pulsed dose delivery did
2014-04-15
the floor on which the platform is dropped upon. Alternatively, a base excitation can be provided to the sliding platform in the upward vertical...7ms clips of chest resultant acceleration, (7) 7ms clip of pelvic vertical acceleration, (8,9) Peak and 30ms clips of lumbar spine compression, and...10) Pelvic vertical Dynamic Response Index (DRI)[12]. The sample size for each of the three seating variants consisted of 230 MADYMO
Congenital Symmastia: A 3-Step Approach
Allam, Atef A.
2016-01-01
Summary: Congenital symmastia is a medial confluence of the breasts. It is a rare anomaly with few reports in the literature and no standard treatment. In this article, we present a case of congenital symmastia treated by 3 steps: liposuction, fixation of the skin to the chest wall in the area of the intermammary sulcus, and postoperative intermammary compression. A successful result was achieved with normal cleavage between the breasts. So, this is considered the ideal treatment for this condition. PMID:28293510
Dynamic Range Enhancement of High-Speed Electrical Signal Data via Non-Linear Compression
NASA Technical Reports Server (NTRS)
Laun, Matthew C. (Inventor)
2016-01-01
Systems and methods for high-speed compression of dynamic electrical signal waveforms to extend the measuring capabilities of conventional measuring devices such as oscilloscopes and high-speed data acquisition systems are discussed. Transfer function components and algorithmic transfer functions can be used to accurately measure signals that are within the frequency bandwidth but beyond the voltage range and voltage resolution capabilities of the measuring device.
Anegg, Udo; Lindenmann, Jorg; Matzi, Veronika; Mujkic, Dzenana; Maier, Alfred; Fritz, Lukas; Smolle-Jüttner, Freyja Maria
2006-06-01
Prolonged air leak after pulmonary resection is a common complication and a major limiting factor for early discharge from hospital. Currently there is little consensus on its management. The aim of this study was to develop and evaluate a measuring device which allows a simple digital bed-side quantification of air-leaks compatible to standard thoracic drainage systems. The measuring device (AIRFIX) is based upon a 'mass airflow' sensor with a specially designed software package that is connected to a thoracic suction drainage system. Its efficacy in detecting pulmonary air-leaks was evaluated in a series of 204 patients; all postoperative measurements were done under standardized conditions; the patients were asked to cough, to take a deep breath, to breathe out against the resistance of a flutter valve, to keep breath and to breathe normally. As standard parameters, the leakage per breath or cough (ml/b) as well as the leakage per minute (ml/min) were displayed and recorded on the computer. Air-leaks within a range of 0.25-45 ml/b and 5-900 ml/min were found. Removal of the chest tubes was done when leakage volume on Heimlich valve was less than 1.0 ml/b or 20 ml/min. After drain removal based upon the data from chest tube airflowmetry none of the patients needed re-drainage due to pneumothorax. The AIRFIX device for bed-side quantification of air-leaks has proved to be very simple and helpful in diagnosis and management of air-leaks after lung surgery, permitting drain removal without tentative clamping.
Rehm, K; Seeley, G W; Dallas, W J; Ovitt, T W; Seeger, J F
1990-01-01
One of the goals of our research in the field of digital radiography has been to develop contrast-enhancement algorithms for eventual use in the display of chest images on video devices with the aim of preserving the diagnostic information presently available with film, some of which would normally be lost because of the smaller dynamic range of video monitors. The ASAHE algorithm discussed in this article has been tested by investigating observer performance in a difficult detection task involving phantoms and simulated lung nodules, using film as the output medium. The results of the experiment showed that the algorithm is successful in providing contrast-enhanced, natural-looking chest images while maintaining diagnostic information. The algorithm did not effect an increase in nodule detectability, but this was not unexpected because film is a medium capable of displaying a wide range of gray levels. It is sufficient at this stage to show that there is no degradation in observer performance. Future tests will evaluate the performance of the ASAHE algorithm in preparing chest images for video display.
NASA Astrophysics Data System (ADS)
Lv, Peng; Tang, Xun; Yuan, Jiajiao; Ji, Chenglong
2017-11-01
Highly compressible electrodes are in high demand in volume-restricted energy storage devices. Superelastic reduced graphene oxide (rGO) aerogel with attractive characteristics are proposed as the promising skeleton for compressible electrodes. Herein, a ternary aerogel was prepared by successively electrodepositing polypyrrole (PPy) and MnO2 into the superelastic rGO aerogel. In the rGO/PPy/MnO2 aerogel, rGO aerogel provides the continuously conductive network; MnO2 is mainly responsible for pseudo reactions; the middle PPy layer not only reduces the interface resistance between rGO and MnO2, but also further enhanced the mechanical strength of rGO backbone. The synergistic effect of the three components leads to excellent performances including high specific capacitance, reversible compressibility, and extreme durability. The gravimetric capacitance of the compressible rGO/PPy/MnO2 aerogel electrodes reaches 366 F g-1 and can retain 95.3% even under 95% compressive strain. And a volumetric capacitance of 138 F cm-3 is achieved, which is much higher than that of other rGO-based compressible electrodes. This volumetric capacitance value can be preserved by 85% after 3500 charge/discharge cycles with various compression conditions. This work will pave the way for advanced applications in the area of compressible energy-storage devices meeting the requirement of limiting space.
Economic analysis of using above ground gas storage devices for compressed air energy storage system
NASA Astrophysics Data System (ADS)
Liu, Jinchao; Zhang, Xinjing; Xu, Yujie; Chen, Zongyan; Chen, Haisheng; Tan, Chunqing
2014-12-01
Above ground gas storage devices for compressed air energy storage (CAES) have three types: air storage tanks, gas cylinders, and gas storage pipelines. A cost model of these gas storage devices is established on the basis of whole life cycle cost (LCC) analysis. The optimum parameters of the three types are determined by calculating the theoretical metallic raw material consumption of these three devices and considering the difficulties in manufacture and the influence of gas storage device number. The LCCs of the three types are comprehensively analyzed and compared. The result reveal that the cost of the gas storage pipeline type is lower than that of the other two types. This study may serve as a reference for designing large-scale CAES systems.
Technology study of quantum remote sensing imaging
NASA Astrophysics Data System (ADS)
Bi, Siwen; Lin, Xuling; Yang, Song; Wu, Zhiqiang
2016-02-01
According to remote sensing science and technology development and application requirements, quantum remote sensing is proposed. First on the background of quantum remote sensing, quantum remote sensing theory, information mechanism, imaging experiments and prototype principle prototype research situation, related research at home and abroad are briefly introduced. Then we expounds compress operator of the quantum remote sensing radiation field and the basic principles of single-mode compression operator, quantum quantum light field of remote sensing image compression experiment preparation and optical imaging, the quantum remote sensing imaging principle prototype, Quantum remote sensing spaceborne active imaging technology is brought forward, mainly including quantum remote sensing spaceborne active imaging system composition and working principle, preparation and injection compression light active imaging device and quantum noise amplification device. Finally, the summary of quantum remote sensing research in the past 15 years work and future development are introduced.