Vezzani, Antonella; Manca, Tullio; Brusasco, Claudia; Santori, Gregorio; Valentino, Massimo; Nicolini, Francesco; Molardi, Alberto; Gherli, Tiziano; Corradi, Francesco
2014-12-01
Chest auscultation and chest x-ray commonly are used to detect postoperative abnormalities and complications in patients admitted to intensive care after cardiac surgery. The aim of the study was to evaluate whether chest ultrasound represents an effective alternative to bedside chest x-ray to identify early postoperative abnormalities. Diagnostic accuracy of chest auscultation and chest ultrasound were compared in identifying individual abnormalities detected by chest x-ray, considered the reference method. Cardiac surgery intensive care unit. One hundred fifty-one consecutive adult patients undergoing cardiac surgery. All patients included were studied by chest auscultation, ultrasound, and x-ray upon admission to intensive care after cardiac surgery. Six lung pathologic changes and endotracheal tube malposition were found. There was a highly significant correlation between abnormalities detected by chest ultrasound and x-ray (k = 0.90), but a poor correlation between chest auscultation and x-ray abnormalities (k = 0.15). Chest auscultation may help identify endotracheal tube misplacement and tension pneumothorax but it may miss most major abnormalities. Chest ultrasound represents a valid alternative to chest x-ray to detect most postoperative abnormalities and misplacements. Copyright © 2014 Elsevier Inc. All rights reserved.
Haddad, Laura; Bubenheim, Michael; Bernard, Alain; Melki, Jean; Peillon, Christophe; Baste, Jean-Marc
2017-10-01
Background There is a lack of consensus in hospital centers regarding costly daily routine chest X-rays after lung resection by minimally invasive surgery. Indeed, there is no evidence that performing daily chest X-rays prevents postoperative complications. Our objective was to compare chest X-rays performed on demand when there was clinical suspicion of postoperative complications and chest X-rays performed systematically in daily routine practice. Methods This prospective single-center study compared 55 patients who had on-demand chest X-rays and patients in the literature who had daily routine chest X-rays. Our primary evaluation criterion was length of hospitalization. Results The length of hospitalization was 5.3 ± 3.3 days for patients who had on-demand X-rays, compared with 4 to 9.7 days for patients who had daily routine X-rays. Time to chest tube removal (4.34 days), overall complication rate (27.2%), reoperation rate (3.6%), and mortality rate (1.8%) were comparable to those in the literature. On average, our patients only had 1.22 ± 1.8 on-demand X-rays, compared with 3.3 X-rays if daily routine protocol had been applied. Patients with complications had more X-rays (3.4 ± 1.8) than patients without complications (0.4 ± 0.7). Conclusion On-demand chest X-rays do not seem to delay the diagnosis of postoperative complications or increase morbidity-mortality rates. Performing on-demand chest X-rays could not only simplify surgical practice but also have a positive impact on health care expenses. However, a broader randomized study is warranted to validate this work and ultimately lead to national consensus. Georg Thieme Verlag KG Stuttgart · New York.
Ultrasound detection of pneumothorax compared with chest X-ray and computed tomography scan.
Nagarsheth, Khanjan; Kurek, Stanley
2011-04-01
Pneumothorax after trauma can be a life threatening injury and its care requires expeditious and accurate diagnosis and possible intervention. We performed a prospective, single blinded study with convenience sampling at a Level I trauma center comparing thoracic ultrasound with chest X-ray and CT scan in the detection of traumatic pneumothorax. Trauma patients that received a thoracic ultrasound, chest X-ray, and chest CT scan were included in the study. The chest X-rays were read by a radiologist who was blinded to the thoracic ultrasound results. Then both were compared with CT scan results. One hundred and twenty-five patients had a thoracic ultrasound performed in the 24-month period. Forty-six patients were excluded from the study due to lack of either a chest X-ray or chest CT scan. Of the remaining 79 patients there were 22 positive pneumothorax found by CT and of those 18 (82%) were found on ultrasound and 7 (32%) were found on chest X-ray. The sensitivity of thoracic ultrasound was found to be 81.8 per cent and the specificity was found to be 100 per cent. The sensitivity of chest X-ray was found to be 31.8 per cent and again the specificity was found to be 100 per cent. The negative predictive value of thoracic ultrasound for pneumothorax was 0.934 and the negative predictive value for chest X-ray for pneumothorax was found to be 0.792. We advocate the use of chest ultrasound for detection of pneumothorax in trauma patients.
Does a chest x-ray alter the management of new patients attending a geriatric day hospital?
Logan, J A; Vallance, R; Williams, B O; Paul, H
1997-01-01
Studies have suggested that routine chest x-ray is never indicated but all new attenders at our day hospitals have a chest x-ray carried out. Our aim was to determine if this investigation altered the clinical management of patients and to try to select those patients in whom a chest x-ray is indicated. A prospective study was carried out over a 7 month period from February to September 1995. All new patients had cardiorespiratory symptoms/signs documented and a management plan made. A chest x-ray was then carried out and change in management as a result of the x-ray report noted. Knightswood and Drumchapel Geriatric Day Hospitals, West Glasgow University NHS Trust. All new Day Hospital attenders. Of 207 new Day Hospital attenders, 53 had no clinical indication for a chest x-ray and although 70% had an abnormal film in no case was patient management changed as a result of this. A chest x-ray was indicated in 154 patients and of these 114 (74%) had an abnormal film with a resultant change in management in 23 patients (this comprised either a change in drug treatment or a further investigation.) Of those whose management was changed as a result of the x-ray report 61% had respiratory symptoms. We would recommend that chest x-ray should be performed in those patients who have a clear clinical indication and that the diagnostic yield is highest in the presence of respiratory symptoms or signs.
Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom
NASA Astrophysics Data System (ADS)
Vodovatov, A. V.; Kamishanskaya, I. G.; Drozdov, A. A.; Bernhardsson, C.
2017-02-01
The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.
20 CFR 718.102 - Chest roentgenograms (X-rays).
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Chest roentgenograms (X-rays). 718.102... roentgenograms (X-rays). (a) A chest roentgenogram (X-ray) shall be of suitable quality for proper classification of pneumoconiosis and shall conform to the standards for administration and interpretation of chest X...
20 CFR 718.102 - Chest roentgenograms (X-rays).
Code of Federal Regulations, 2013 CFR
2013-04-01
... 20 Employees' Benefits 4 2013-04-01 2013-04-01 false Chest roentgenograms (X-rays). 718.102... roentgenograms (X-rays). (a) A chest roentgenogram (X-ray) shall be of suitable quality for proper classification of pneumoconiosis and shall conform to the standards for administration and interpretation of chest X...
20 CFR 718.102 - Chest roentgenograms (X-rays).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 4 2014-04-01 2014-04-01 false Chest roentgenograms (X-rays). 718.102... roentgenograms (X-rays). (a) A chest roentgenogram (X-ray) shall be of suitable quality for proper classification of pneumoconiosis and shall conform to the standards for administration and interpretation of chest X...
20 CFR 718.102 - Chest roentgenograms (X-rays).
Code of Federal Regulations, 2012 CFR
2012-04-01
... 20 Employees' Benefits 4 2012-04-01 2012-04-01 false Chest roentgenograms (X-rays). 718.102... roentgenograms (X-rays). (a) A chest roentgenogram (X-ray) shall be of suitable quality for proper classification of pneumoconiosis and shall conform to the standards for administration and interpretation of chest X...
Touw, H R; Parlevliet, K L; Beerepoot, M; Schober, P; Vonk, A; Twisk, J W; Elbers, P W; Boer, C; Tuinman, P R
2018-03-12
Postoperative pulmonary complications are common after cardiothoracic surgery and are associated with adverse outcomes. The ability to detect postoperative pulmonary complications using chest X-rays is limited, and this technique requires radiation exposure. Little is known about the diagnostic accuracy of lung ultrasound for the detection of postoperative pulmonary complications after cardiothoracic surgery, and we therefore aimed to compare lung ultrasound with chest X-ray to detect postoperative pulmonary complications in this group of patients. We performed this prospective, observational, single-centre study in a tertiary intensive care unit treating adult patients who had undergone cardiothoracic surgery. We recorded chest X-ray findings upon admission and on postoperative days 2 and 3, as well as rates of postoperative pulmonary complications and clinically-relevant postoperative pulmonary complications that required therapy according to the treating physician as part of their standard clinical practice. Lung ultrasound was performed by an independent researcher at the time of chest X-ray. We compared lung ultrasound with chest X-ray for the detection of postoperative pulmonary complications and clinically-relevant postoperative pulmonary complications. We also assessed inter-observer agreement for lung ultrasound, and the time to perform both imaging techniques. Subgroup analyses were performed to compare the time to detection of clinically-relevant postoperative pulmonary complications by both modalities. We recruited a total of 177 patients in whom both lung ultrasound and chest X-ray imaging were performed. Lung ultrasound identified 159 (90%) postoperative pulmonary complications on the day of admission compared with 107 (61%) identified with chest X-ray (p < 0.001). Lung ultrasound identified 11 out of 17 patients (65%) and chest X-ray 7 out of 17 patients (41%) with clinically-relevant postoperative pulmonary complications (p < 0.001). The clinically-relevant postoperative pulmonary complications were detected earlier using lung ultrasound compared with chest X-ray (p = 0.024). Overall inter-observer agreement for lung ultrasound was excellent (κ = 0.907, p < 0.001). Following cardiothoracic surgery, lung ultrasound detected more postoperative pulmonary complications and clinically-relevant postoperative pulmonary complications than chest X-ray, and at an earlier time-point. Our results suggest lung ultrasound may be used as the primary imaging technique to search for postoperative pulmonary complications after cardiothoracic surgery, and will enhance bedside decision making. © 2018 The Authors. Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.
Chest X-Ray (Chest Radiography)
... may be necessary to clarify the results of a chest x-ray or to look for abnormalities not visible on the chest x-ray. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Lung Cancer top of page This page ...
Dar, Javeed; Mughal, Inam; Hassan, Hilali; Al Mekki, Taj E.; Chapunduka, Zivani; Hassan, Imad S. A.
2010-01-01
Objective: Quantitation of D-dimer level during a sickling crisis and its correlation with other clinical abnormalities. Design: Prospective longitudinal study. Setting: Armed Forces Hospital, Southern Region, Kingdom of Saudi Arabia. Patients: Adult patients (12 years and older) admitted acutely with a sickle cell crisis who consent to taking part in the study. Candidates may re-participate if they are readmitted with a further acute painful crisis. Results: 36 patients with homozygous sickle cell disease consented to take part in the study. D-dimer levels were raised in 31 (68.9%) of 45 episodes of painful crisis of whom 13 had an abnormal chest X-ray. Of those with a normal chest X-ray only one patient had a raised D-dimer level: sensitivity of 92.3%, specificity 40.6%, positive predictive value 38.7% and negative predictive value of 92.9% for an abnormal chest X-ray. Conclusion: D-dimer levels are frequently raised during an acute painful crisis. A normal level has a high negative predictive value for an abnormal chest X-ray. PMID:21063468
Dar, Javeed; Mughal, Inam; Hassan, Hilali; Al Mekki, Taj E; Chapunduka, Zivani; Hassan, Imad S A
2010-10-08
Quantitation of D-dimer level during a sickling crisis and its correlation with other clinical abnormalities. Prospective longitudinal study. Armed Forces Hospital, Southern Region, Kingdom of Saudi Arabia. Adult patients (12 years and older) admitted acutely with a sickle cell crisis who consent to taking part in the study. Candidates may re-participate if they are readmitted with a further acute painful crisis. 36 patients with homozygous sickle cell disease consented to take part in the study. D-dimer levels were raised in 31 (68.9%) of 45 episodes of painful crisis of whom 13 had an abnormal chest X-ray. Of those with a normal chest X-ray only one patient had a raised D-dimer level: sensitivity of 92.3%, specificity 40.6%, positive predictive value 38.7% and negative predictive value of 92.9% for an abnormal chest X-ray. D-dimer levels are frequently raised during an acute painful crisis. A normal level has a high negative predictive value for an abnormal chest X-ray.
Point-of-care lung ultrasound in children with community acquired pneumonia.
Yilmaz, Hayri Levent; Özkaya, Ahmet Kağan; Sarı Gökay, Sinem; Tolu Kendir, Özlem; Şenol, Hande
2017-07-01
To present lung ultrasound findings in children assessed with suspected pneumonia in the emergency department and to show the benefit of lung ultrasound in diagnosing pneumonia in comparison with chest X-rays. This observational prospective study was performed in the pediatric emergency department of a single center. Point of care lung ultrasound was performed on each child by an independent sonographer blinded to the patient's clinical and chest X-ray findings. Community acquired pneumonia was established as a final diagnosis by two clinicians based on the recommendations in the British Thoracic Society guideline. One hundred sixty children with a mean age of 3.3±4years and a median age of 1.4years (min-max 0.08-17.5years) were investigated. Final diagnosis in 149 children was community-acquired pneumonia. Lung ultrasound findings were compatible with pneumonia in 142 (95.3%) of these 149 children, while chest X-ray findings were compatible with pneumonia in 132 (88.5%). Pneumonia was confirmed with lung ultrasound in 15 of the 17 patients (11.4%) not evaluated as compatible with pneumonia at chest X-ray. While pneumonia could not be confirmed with lung ultrasound in seven (4.6%) patients, findings compatible with pneumonia were not determined at chest X-ray in two of these patients. When lung ultrasound and chest X-ray were compared as diagnostic tools, a significant difference was observed between them (p=0.041). This study shows that lung ultrasound is at least as useful as chest X-ray in diagnosing children with community-acquired pneumonia. Copyright © 2017 Elsevier Inc. All rights reserved.
First experience with x-ray dark-field radiography for human chest imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
Noel, Peter B.; Willer, Konstantin; Fingerle, Alexander A.; Gromann, Lukas B.; De Marco, Fabio; Scherer, Kai H.; Herzen, Julia; Achterhold, Klaus; Gleich, Bernhard; Münzel, Daniela; Renz, Martin; Renger, Bernhard C.; Fischer, Florian; Braun, Christian; Auweter, Sigrid; Hellbach, Katharina; Reiser, Maximilian F.; Schröter, Tobias; Mohr, Jürgen; Yaroshenko, Andre; Maack, Hanns-Ingo; Pralow, Thomas; van der Heijden, Hendrik; Proksa, Roland; Köhler, Thomas; Wieberneit, Nataly; Rindt, Karsten; Rummeny, Ernst J.; Pfeiffer, Franz
2017-03-01
Purpose: To evaluate the performance of an experimental X-ray dark-field radiography system for chest imaging in humans and to compare with conventional diagnostic imaging. Materials and Methods: The study was institutional review board (IRB) approved. A single human cadaver (52 years, female, height: 173 cm, weight: 84 kg, chest circumference: 97 cm) was imaged within 24 hours post mortem on the experimental x-ray dark-field system. In addition, the cadaver was imaged on a clinical CT system to obtain a reference scan. The grating-based dark-field radiography setup was equipped with a set of three gratings to enable grating-based dark-field contrast x-ray imaging. The prototype operates at an acceleration voltage of up to 70 kVp and with a field-of-view large enough for clinical chest x-ray (>35 x 35 cm2). Results: It was feasible to extract x-ray dark-field signal of the whole human thorax, clearly demonstrating that human x-ray dark-field chest radiography is feasible. Lung tissue produced strong scattering, reflected in a pronounced x-ray dark-field signal. The ribcage and the backbone are less prominent than the lung but are also distinguishable. Finally, the soft tissue is not present in the dark-field radiography. The regions of the lungs affected by edema, as verified by CT, showed less dark-field signal compared to healthy lung tissue. Conclusion: Our results reveal the current status of translating dark-field imaging from a micro (small animal) scale to a macro (patient) scale. The performance of the experimental x-ray dark-field radiography setup offers, for the first time, obtaining multi-contrast chest x-ray images (attenuation and dark-field signal) from a human cadaver.
McClester Brown, Mallory; Sloane, Philip D; Kistler, Christine E; Reed, David; Ward, Kimberly; Weber, David; Zimmerman, Sheryl
2016-12-01
Pneumonia is a leading cause of morbidity and mortality in nursing home (NH) residents. Chest x-ray evidence is considered a key diagnostic criterion for pneumonia by the Infectious Disease Society of America (IDSA) diagnostic guidelines, the modified McGeer diagnostic criteria, and the Loeb criteria for initiating antibiotics; however, x-ray interpretation is often equivocal. We conducted chart audits of patients in NHs who had chest x-rays for new respiratory symptoms to determine the degree of ambiguity in the radiology reports and their relationship to antibiotic prescription decisions. Cross-sectional study. Thirty-one NHs in North Carolina. Two hundred twenty-six NH residents who had a chest x-ray. Medical charts were abstracted to record (1) the patient's clinical presentation when a chest x-ray was ordered, (2) the verbatim report of the chest x-ray, and (3) the patient's course during the subsequent 7 days. To standardize the radiologist reports, a seven-category coding system was developed, which was further aggregated into three groups based on the radiologist's description of the likelihood of pneumonia. Of the 226 chest x-rays, 118 (52%) identified a very low likelihood of pneumonia, 67 (30%) indicated that pneumonia was present or highly likely, and the remaining 41 (18%) used a variety of terms to describe uncertainty regarding the presence of pneumonia. NH medical providers tended to treat ambiguous chest x-ray reports similarly to positive x-ray reports, prescribing antibiotic therapy to 71% of patients with ambiguous reports and 78% of positive reports. Also notable is that 40 (34%) of the 118 patients with a very low likelihood of pneumonia based on chest x-ray results were prescribed antibiotics, the majority of whom failed to meet criteria for a clinical diagnosis of pneumonia or chronic obstructive pulmonary disease exacerbation. The moderate rate of ambiguous x-ray interpretations in NH residents is likely a combination of the poor quality of portable x-rays, a high prevalence of chronic lung conditions, and conservative (ie, cautious) decision making by radiologists whose interpretation is based on little clinical information and a suboptimal quality film. As a result, data suggest that chest x-rays obtained in NHs may unnecessarily encourage antibiotic prescribing because a majority of readings are ambiguous or show a low likelihood of pneumonia, yet more than half of the patients are still treated. From an antibiotic stewardship standpoint, the apparent solution is to more closely rely on clinical signs and symptoms for diagnosis of pneumonia and to place less emphasis on the role of the chest x-ray given the high number of unclear readings. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Interpretation of Chest Roentgenograms (X-Rays) A Appendix A to Part 718 Employees' Benefits OFFICE OF WORKERS... Appendix A to Part 718—Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays) The... procedures are used in administering and interpreting X-rays and that the best available medical evidence...
Code of Federal Regulations, 2013 CFR
2013-04-01
... Interpretation of Chest Roentgenograms (X-Rays) A Appendix A to Part 718 Employees' Benefits OFFICE OF WORKERS... Appendix A to Part 718—Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays) The... procedures are used in administering and interpreting X-rays and that the best available medical evidence...
Code of Federal Regulations, 2011 CFR
2011-04-01
... Interpretation of Chest Roentgenograms (X-Rays) A Appendix A to Part 718 Employees' Benefits OFFICE OF WORKERS... Appendix A to Part 718—Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays) The... procedures are used in administering and interpreting X-rays and that the best available medical evidence...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Interpretation of Chest Roentgenograms (X-Rays) A Appendix A to Part 718 Employees' Benefits OFFICE OF WORKERS... Appendix A to Part 718—Standards for Administration and Interpretation of Chest Roentgenograms (X-Rays) The... procedures are used in administering and interpreting X-rays and that the best available medical evidence...
Performance of chest ultrasound in pediatric pneumonia.
Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana
2017-03-01
The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. 143 children (mean age 3 years; limits between 8days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4mm; for consolidations visible on both techniques the mean size was 26mm (p<0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus reducing radiation exposure in this population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Accuracy of remote chest X-ray interpretation using Google Glass technology.
Spaedy, Emily; Christakopoulos, Georgios E; Tarar, Muhammad Nauman J; Christopoulos, Georgios; Rangan, Bavana V; Roesle, Michele; Ochoa, Cristhiaan D; Yarbrough, William; Banerjee, Subhash; Brilakis, Emmanouil S
2016-09-15
We sought to explore the accuracy of remote chest X-ray reading using hands-free, wearable technology (Google Glass, Google, Mountain View, California). We compared interpretation of twelve chest X-rays with 23 major cardiopulmonary findings by faculty and fellows from cardiology, radiology, and pulmonary-critical care via: (1) viewing the chest X-ray image on the Google Glass screen; (2) viewing a photograph of the chest X-ray taken using Google Glass and interpreted on a mobile device; (3) viewing the original chest X-ray on a desktop computer screen. One point was given for identification of each correct finding and a subjective rating of user experience was recorded. Fifteen physicians (5 faculty and 10 fellows) participated. The average chest X-ray reading score (maximum 23 points) as viewed through the Google Glass, Google Glass photograph on a mobile device, and the original X-ray viewed on a desktop computer was 14.1±2.2, 18.5±1.5 and 21.3±1.7, respectively (p<0.0001 between Google Glass and mobile device, p<0.0001 between Google Glass and desktop computer and p=0.0004 between mobile device and desktop computer). Of 15 physicians, 11 (73.3%) felt confident in detecting findings using the photograph taken by Google Glass as viewed on a mobile device. Remote chest X-ray interpretation using hands-free, wearable technology (Google Glass) is less accurate than interpretation using a desktop computer or a mobile device, suggesting that further technical improvements are needed before widespread application of this novel technology. Published by Elsevier Ireland Ltd.
ERIC Educational Resources Information Center
Thompson, Michael; Johansen, Dallin; Stoner, Russell; Jarsted, Allison; Sorrells, Robert; McCarroll, Michele L.; Justice, Wade
2017-01-01
The chest X-ray is the most commonly performed medical imaging study; however, the lateral chest film intimidates many physicians and medical students. The lateral view is more difficult to interpret than the frontal view but provides important information that is either not visible or not as evident on frontal view, and inability to read it may…
Oblique Chest X-Ray: An Alternative Way to Detect Pneumothorax.
Tulay, Cumhur Murat; Yaldız, Sadık; Bilge, Adnan
2018-03-16
To identify occult pneumothorax with oblique chest X-ray (OCXR) in clinically suspected patients. In this retrospective study, we examined 1082 adult multitrauma patients who were admitted to our emergency service between January 2016 and January 2017. Clinical findings that suggest occult pneumothorax were rib fracture, flail chest, chest pain, subcutaneous emphysema, abrasion or ecchymosis and moderate to severe hypoxia in clinical parameters. All of these patients underwent anteroposterior chest X-ray (APCXR), but no pneumothorax could be detected. Upon this, OCXR was performed using mobile X-ray equipment. Traumatic pneumothorax was observed in 421 (38.9%) of 1082 patients. We applied OCXR to 26 multitrauma patients. Occult pneumothorax was evaluated at 22 patients (2.03%) in 1082 multitrauma patients. The 22 patients who had multitrauma occult pneumothorax on OCXR were internated at intensive care unit (ICU) and follow-up was done using OCXR and APCXR. OCXR can be an alternative imaging technique to identify occult pneumothorax in some trauma patients at emergency room and also follow period at ICU.
... provider will listen to your breathing with a stethoscope. If you have a collapsed lung, there are ... rupture, chest x-ray Pneumothorax - chest x-ray Respiratory system Chest tube insertion - series Pneumothorax - series References ...
Wen, Yufeng; Zhang, Zhiping; Li, Xianxiang; Xia, Dan; Ma, Jun; Dong, Yuanyuan; Zhang, Xinwei
2018-03-05
Monitoring the treatment outcomes of tuberculosis and determining the specific factors associated with unsuccessful treatment outcome are essential to evaluate the effectiveness of tuberculosis control program. This study aimed to assess treatment outcomes and explore the factors associated with unsuccessful outcomes among new pulmonary smear positive and negative tuberculosis patients in Anqing, China. A nine-year retrospective study was conducted using data from Anqing Center for Diseases Prevention and Control. New pulmonary tuberculosis patients treated with two six-month regimens were investigated. Non-conditional logistic regression was performed to calculate odds ratios and 95% confidence intervals for factors associated with unsuccessful outcomes. Among 22,998 registered patients (16,939 males, 6059 females), 64.54% were smear-positive patients. The treatment success rates was 95.02% for smear-positive patients and 95.00% for smear-negative patients. Characteristics associated with an higher risk of unsuccessful treatment among smear-positive patients included aged above 35 years, treatment management model of self-medication, full-course management and supervision in intensive phase, unchecked chest X-ray, cavity in chest X-ray, and miliary shadow in chest X-ray, while normal X-ray was negative factor. Unsuccessful treatment among smear-negative patients was significantly associated with age over 45 years, treatment management model of full-course management, unchecked chest X-ray, presence of miliary shadow in chest X-ray and delay over 51 days. Tuberculosis treatment in Anqing area was successful and independent of treatment regimens. Special efforts are required for patients with unsuccessful outcomes.
[Development of a digital chest phantom for studies on energy subtraction techniques].
Hayashi, Norio; Taniguchi, Anna; Noto, Kimiya; Shimosegawa, Masayuki; Ogura, Toshihiro; Doi, Kunio
2014-03-01
Digital chest phantoms continue to play a significant role in optimizing imaging parameters for chest X-ray examinations. The purpose of this study was to develop a digital chest phantom for studies on energy subtraction techniques under ideal conditions without image noise. Computed tomography (CT) images from the LIDC (Lung Image Database Consortium) were employed to develop a digital chest phantom. The method consisted of the following four steps: 1) segmentation of the lung and bone regions on CT images; 2) creation of simulated nodules; 3) transformation to attenuation coefficient maps from the segmented images; and 4) projection from attenuation coefficient maps. To evaluate the usefulness of digital chest phantoms, we determined the contrast of the simulated nodules in projection images of the digital chest phantom using high and low X-ray energies, soft tissue images obtained by energy subtraction, and "gold standard" images of the soft tissues. Using our method, the lung and bone regions were segmented on the original CT images. The contrast of simulated nodules in soft tissue images obtained by energy subtraction closely matched that obtained using the gold standard images. We thus conclude that it is possible to carry out simulation studies based on energy subtraction techniques using the created digital chest phantoms. Our method is potentially useful for performing simulation studies for optimizing the imaging parameters in chest X-ray examinations.
[Radiation exposure of children in pediatric radiology. Part 5: organ doses in chest radiography].
Seidenbusch, M C; Schneider, K
2009-05-01
Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of the X-ray field and the beam direction of X-rays. Optimal collimation in chest radiography can reduce the exposure of organs located at the periphery of the X-ray field, e. g. thyroid gland, stomach and partially the liver, by a factor of 2 to 3, while organs located in the center of the X-ray-field, e. g. thymus, breasts, lungs, esophagus and red bone marrow, are not affected by exact collimation. The high frequency of the roentgen examination of the chest in early age groups increases the collective radiation burden to radiosensitive organs. Therefore, radiation protection of the patient during chest radiographies remains of great importance.
Atif, Muhammad; Sulaiman, Syed Azhar Syed; Shafie, Asrul Akmal; Saleem, Fahad; Ahmad, Nafees
2012-01-01
Activity based costing (ABC) is an approach to get insight of true costs and to solve accounting problems. It provides more accurate information on product cost than conventional accounting system. The purpose of this study was to identify detailed resource consumption for chest x-ray procedure. Human resource cost was calculated by multiplying the mean time spent by employees doing specific activity to their per-minute salaries. The costs of consumables and clinical equipments were obtained from the procurement section of the Radiology Department. The cost of the building was calculated by multiplying the area of space used by the chest X-ray facility with the unit cost of public building department. Moreover, straight-line deprecation with a discount rate of 3% was assumed for calculation of equivalent annual costs for building and machines. Cost of electricity was calculated by multiplying number of kilo watts used by electrical appliance in the year 2010 with electricity tariff for Malaysian commercial consumers (MYR 0.31 per kWh). Five activities were identified which were required to develop one chest X-ray film. Human resource, capital, consumable and electricity cost was MYR 1.48, MYR 1.98, MYR 2.15 and MYR 0.04, respectively. Total cost of single chest X-ray was MYR 5.65 (USD 1.75). By applying ABC approach, we can have more detailed and precise estimate of cost for specific activity or service. Choice of repeating a chest X-ray can be based on our findings, when cost is a limiting factor.
Conventional vs invert-grayscale X-ray for diagnosis of pneumothorax in the emergency setting.
Musalar, Ekrem; Ekinci, Salih; Ünek, Orkun; Arş, Eda; Eren, Hakan Şevki; Gürses, Bengi; Aktaş, Can
2017-09-01
Pneumothorax is a pathologic condition in which air is accumulated between the visceral and parietal pleura. After clinical suspicion, in order to diagnose the severity of the condition, imaging is necessary. By using the help of Picture Archiving and Communication Systems (PACS) direct conventional X-rays are converted to gray-scale and this has become a preferred method among many physicians. Our study design was a case-control study with cross-over design study. Posterior-anterior chest X-rays of patients were evaluated for pneumothorax by 10 expert physicians with at least 3years of experience and who have used inverted gray-scale posterior anterior chest X-ray for diagnosing pneumothorax. The study included posterior anterior chest X-ray images of 268 patients of which 106 were diagnosed with spontaneous pneumothorax and 162 patients used as a control group. The sensitivity of Digital-conventional X-rays was found to be higher than that of inverted gray-scale images (95% CI (2,08-5,04), p<0,01). There was no statistically significant difference between the gold standard and digital-conventional images (95% CI (0,45-2,17), p=0,20), while the evaluations of the gray-scale images were found to be less sensitive for diagnosis (95% CI (3,16-5,67) p<0,01). Inverted gray-scale imaging is not a superior imaging modality over digital-conventional X-ray for the diagnosis of pneumothorax. Prospective studies should be performed where diagnostic potency of inverted gray-scale radiograms is tested against gold standard chest CT. Further research should compare inverted grayscale to lung ultrasound to assess them as alternatives prior to CT. Copyright © 2017 Elsevier Inc. All rights reserved.
Initial clinical evaluation of stationary digital chest tomosynthesis
NASA Astrophysics Data System (ADS)
Hartman, Allison E.; Shan, Jing; Wu, Gongting; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping; Heath, Michael; Wang, Xiaohui; Foos, David
2016-03-01
Computed Tomography (CT) is the gold standard for image evaluation of lung disease, including lung cancer and cystic fibrosis. It provides detailed information of the lung anatomy and lesions, but at a relatively high cost and high dose of radiation. Chest radiography is a low dose imaging modality but it has low sensitivity. Digital chest tomosynthesis (DCT) is an imaging modality that produces 3D images by collecting x-ray projection images over a limited angle. DCT is less expensive than CT and requires about 1/10th the dose of radiation. Commercial DCT systems acquire the projection images by mechanically scanning an x-ray tube. The movement of the tube head limits acquisition speed. We recently demonstrated the feasibility of stationary digital chest tomosynthesis (s-DCT) using a carbon nanotube (CNT) x-ray source array in benchtop phantom studies. The stationary x-ray source allows for fast image acquisition. The objective of this study is to demonstrate the feasibility of s-DCT for patient imaging. We have successfully imaged 31 patients. Preliminary evaluation by board certified radiologists suggests good depiction of thoracic anatomy and pathology.
Solti, Imre; Cooke, Colin R; Xia, Fei; Wurfel, Mark M
2009-11-01
This paper compares the performance of keyword and machine learning-based chest x-ray report classification for Acute Lung Injury (ALI). ALI mortality is approximately 30 percent. High mortality is, in part, a consequence of delayed manual chest x-ray classification. An automated system could reduce the time to recognize ALI and lead to reductions in mortality. For our study, 96 and 857 chest x-ray reports in two corpora were labeled by domain experts for ALI. We developed a keyword and a Maximum Entropy-based classification system. Word unigram and character n-grams provided the features for the machine learning system. The Maximum Entropy algorithm with character 6-gram achieved the highest performance (Recall=0.91, Precision=0.90 and F-measure=0.91) on the 857-report corpus. This study has shown that for the classification of ALI chest x-ray reports, the machine learning approach is superior to the keyword based system and achieves comparable results to highest performing physician annotators.
Solti, Imre; Cooke, Colin R.; Xia, Fei; Wurfel, Mark M.
2010-01-01
This paper compares the performance of keyword and machine learning-based chest x-ray report classification for Acute Lung Injury (ALI). ALI mortality is approximately 30 percent. High mortality is, in part, a consequence of delayed manual chest x-ray classification. An automated system could reduce the time to recognize ALI and lead to reductions in mortality. For our study, 96 and 857 chest x-ray reports in two corpora were labeled by domain experts for ALI. We developed a keyword and a Maximum Entropy-based classification system. Word unigram and character n-grams provided the features for the machine learning system. The Maximum Entropy algorithm with character 6-gram achieved the highest performance (Recall=0.91, Precision=0.90 and F-measure=0.91) on the 857-report corpus. This study has shown that for the classification of ALI chest x-ray reports, the machine learning approach is superior to the keyword based system and achieves comparable results to highest performing physician annotators. PMID:21152268
The recent development of an X-ray grating interferometer at Shanghai Synchrotron Radiation Facility
NASA Astrophysics Data System (ADS)
Sun, Haohua; Kou, Bingquan; Xi, Yan; Qi, Juncheng; Sun, Jianqi; Mohr, Jürgen; Börner, Martin; Zhao, Jun; Xu, Lisa X.; Xiao, Tiqiao; Wang, Yujie
2012-07-01
An X-ray grating interferometer has been installed at Shanghai Synchrotron Radiation Facility (SSRF). Three sets of phase gratings were designed to cover the wide X-ray energy range needed for biological and soft material imaging capabilities. The performance of the grating interferometer has been evaluated by a tomography study of a PMMA particle packing and a new born mouse chest. In the mouse chest study, the carotid artery and carotid vein inside the mouse can be identified in situ without contrast agents.
Fingland, P; Carswell, V; Tikka, T; Douglas, C M; Montgomery, J
2018-04-30
In Scotland, patients with suspected head and neck cancer are referred on the basis of the Scottish Referral Guidelines for Suspected Cancer, rather than the National Institute for Health and Care Excellence guidelines. A chest X-ray should be requested by the general practitioner at the same time as referral for persistent hoarseness. The evidence for this is level 4. This audit identified adherence to this recommendation and X-ray results. All 'urgent suspicion of cancer' referrals to the ENT department in the National Health Service Greater Glasgow and Clyde for 2015-2016 were audited. Persistent hoarseness for more than 3 weeks instigated referral in 318 patients (15.7 per cent). Chest X-ray was performed in 120 patients (38 per cent), which showed: no abnormality in 116 (96.7 per cent), features of infection in 2 (1.7 per cent) and something else in 2 patients (1.7 per cent). No chest X-ray altered the management of a patient. Performance of chest X-ray does not alter management and its removal from the Scottish Referral Guidelines for Suspected Cancer is recommended.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-14
... DS-2053, DS-2054; Medical Examination for Immigrant or Refugee Applicant; DS- 3024, DS-3030, Chest X... Instructions); Form DS- 3024, Chest X-Ray and Classification Worksheet (1991 Technical Instructions); Form DS-3030, Chest X-Ray and Classification Worksheet (2007 Technical Instructions); Form DS-3025, Vaccination...
Vignon, P; Lagrange, P; Boncoeur, M P; Francois, B; Gastinne, H; Lang, R M
1996-03-01
To assess the value of routine transesophageal echocardiography (TEE) in diagnosing traumatic disruption of the aorta (TDA) in trauma patients presenting without enlarged mediastinum on chest x-ray films. Prospective study. TEE was routinely performed to exclude the presence of TDA in patients who sustained severe trauma secondary to abrupt deceleration collisions and presented with an upper mediastinum of fewer than 8 cm on supine chest x-ray films. Patients were divided into two groups according to the presence (group I) or absence (group II) of mediastinal hematoma diagnosed during TEE examination. Radiographic signs regarded as indicators of the presence of TDA were evaluated in both groups. Among the 40 consecutive patients studied, TEE demonstrated two cases of TDA associated with a mediastinal hematoma that were confirmed by both aortography and surgery. One of the patients had a normal mediastinum on presentation chest x-ray films, and the other only exhibited a blurred aortic knob. Radiographic mediastinal abnormalities suggestive of TDA were observed in 13 patients, but chest x-ray films were unremarkable in 12 patients. Twenty patients had multiple rib fractures. The frequency of chest radiographic abnormalities was not significantly higher in group I (n = 6) when compared with group II patients (n = 34). TEE examination demonstrated a normal thoracic aorta in 35 patients and was nondiagnostic in 3 patients (normal aortography). TEE should be routinely performed in victims of violent deceleration collisions, even in patients presenting apparently normal mediastinum on supine chest radiography.
MedlinePlus Videos and Cool Tools
... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...
... the esophagus and the stomach. Chest x-ray ECG (electrocardiogram, or heart tracing) Fluids by IV (through ... in the airways and lungs. Chest x-ray ECG (electrocardiogram, or heart tracing) Fluids by IV (through ...
Fraioli, F; Serra, G; Ciarlo, G; Massaccesi, V; Liberali, S; Fiorelli, A; Macrì, F; Catalano, C
2013-04-01
The authors evaluated the role of magnetic resonance (MR) imaging of the chest in comparison with chest X-ray in the follow-up of pulmonary abnormalities detected by computed tomography (CT) in paediatric patients with middle lobe syndrome. Seventeen patients with middle lobe syndrome (mean age 6.2 years) underwent chest CT at the time of diagnosis (100 kV, CARE dose with quality reference of 70 mAs; collimation 24×1.2 mm; rotation time 0.33 s; scan time 5 s); at follow-up after a mean of 15.3 months, all patients were evaluated with chest MR imaging with a respiratory-triggered T2-weighted BLADE sequence (TR 2,000; TE 27 ms; FOV 400 mm; flip angle 150°; slice thickness 5 mm) and chest X-ray. Images from each modality were assessed for the presence of pulmonary consolidations, bronchiectases, bronchial wall thickening and mucous plugging. Hilar and mediastinal lymphadenopathies were assessed on CT and MR images. Baseline CT detected consolidations in 100% of patients, bronchiectases in 35%, bronchial wall thickening in 53% and mucous plugging in 35%. MR imaging and chest X-ray identified consolidations in 65% and 35%, bronchiectases in 35% and 29%, bronchial wall thickening in 59% and 6% and mucous plugging in 25% and 0%, respectively. Lymphadenopathy was seen in 64% of patients at CT and in 47% at MR imaging. Patients with middle lobe syndrome show a wide range of parenchymal and bronchial abnormalities at diagnosis. Compared with MR imaging, chest X-ray seems to underestimate these changes. Chest MR imaging might represent a feasible and radiation-free option for an overall assessment of the lung in the follow-up of patients with middle lobe syndrome.
Tuberculosis, advanced - chest x-rays (image)
Tuberculosis is an infectious disease that causes inflammation, the formation of tubercules and other growths within tissue, ... death. These chest x-rays show advanced pulmonary tuberculosis. There are multiple light areas (opacities) of varying ...
Levine, Betty A; Ingeholm, Mary Lou; Prior, Fred; Mun, Seong K; Freedman, Matthew; Weissman, David; Attfield, Michael; Wolfe, Anita; Petsonk, Edward
2009-01-01
To protect the health of active U.S. underground coal miners, the National Institute for Occupational Safety and Health (NIOSH) has a mandate to carry out surveillance for coal workers' pneumoconiosis, commonly known as Black Lung (PHS 2001). This is accomplished by reviewing chest x-ray films obtained from miners at approximately 5-year intervals in approved x-ray acquisition facilities around the country. Currently, digital chest images are not accepted. Because most chest x-rays are now obtained in digital format, NIOSH is redesigning the surveillance program to accept and manage digital x-rays. This paper highlights the functional and security requirements for a digital image management system for a surveillance program. It also identifies the operational differences between a digital imaging surveillance network and a clinical Picture Archiving Communication Systems (PACS) or teleradiology system.
Rodriguez, Robert M; Hendey, Gregory W; Mower, William R
2017-01-01
Chest imaging plays a prominent role in blunt trauma patient evaluation, but indiscriminate imaging is expensive, may delay care, and unnecessarily exposes patients to potentially harmful ionizing radiation. To improve diagnostic chest imaging utilization, we conducted 3 prospective multicenter studies over 12years to derive and validate decision instruments (DIs) to guide the use of chest x-ray (CXR) and chest computed tomography (CT). The first DI, NEXUS Chest x-ray, consists of seven criteria (Age >60years; rapid deceleration mechanism; chest pain; intoxication; altered mental status; distracting painful injury; and chest wall tenderness) and exhibits a sensitivity of 99.0% (95% confidence interval [CI] 98.2-99.4%) and a specificity of 13.3% (95% CI, 12.6%-14.0%) for detecting clinically significant injuries. We developed two NEXUS Chest CT DIs, which are both highly reliable in detecting clinically major injuries (sensitivity of 99.2%; 95% CI 95.4-100%). Designed primarily to focus on detecting major injuries, the NEXUS Chest CT-Major DI consists of six criteria (abnormal CXR; distracting injury; chest wall tenderness; sternal tenderness; thoracic spine tenderness; and scapular tenderness) and exhibits higher specificity (37.9%; 95% CI 35.8-40.1%). Designed to reliability detect both major and minor injuries (sensitivity 95.4%; 95% CI 93.6-96.9%) with resulting lower specificity (25.5%; 95% CI 23.5-27.5%), the NEXUS CT-All rule consists of seven elements (the six NEXUS CT-Major criteria plus rapid deceleration mechanism). The purpose of this review is to synthesize the three DIs into a novel, cohesive summary algorithm with practical implementation recommendations to guide selective chest imaging in adult blunt trauma patients. Copyright © 2016 Elsevier Inc. All rights reserved.
[Value of chest x-ray films in the diagnosis of congenital heart defects in infants].
Koczyński, A
1982-01-01
The respiratory distress and suspicion of the heart defects in newborns and infants is indicated by x-ray chest examinations. The right interpretation of the x-ray pictures is very important but it must be followed by other diagnostic procedures. In every child it is possible to take the linear measurements of the great vessels and arteries in parahilar lung areas as well as the heart and chest in two dimensions from x-ray plain films. The measurements let to establish the indices: cardio-thoracic (ICP), vasculo-cardiac (IVC) and sagittal one (IS), which play important role in radiological evaluation of the chest. It results from the investigated material, that the evaluation of the pulmonary vascular pattern and the indices particularly facilitate the diagnosis of heart deformities coexisting with higher blood flow in pulmonary circulation. Nevertheless the measurements and the indices play the relative role in establishing of the final opinion about the chest and should be considered together with clinical and cardiological data.
NASA Astrophysics Data System (ADS)
Rill, Lynn Neitzey
Chest radiography is technically difficult because of the wide variation of tissue attenuations in the chest and limitations of screen-film systems. Mobile chest radiography, performed bedside on hospital inpatients, presents additional difficulties due to geometrical and equipment limitations inherent to mobile x-ray procedures and the severity of illness in patients. Computed radiography (CR) offers a new approach for mobile chest radiography by utilizing a photostimulable phosphor. Photostimulable phosphors are more efficient in absorbing lower-energy x-rays than standard intensifying screens and overcome some image quality limitations of mobile chest imaging, particularly because of the inherent latitude. This study evaluated changes in imaging parameters for CR to take advantage of differences between CR and screen-film radiography. Two chest phantoms, made of acrylic and aluminum, simulated x-ray attenuation for average-sized and large- sized adult chests. The phantoms contained regions representing the lungs, heart and subdiaphragm. Acrylic and aluminum disks (1.9 cm diameter) were positioned in the chest regions to make signal-to-noise ratio (SNR) measurements for different combinations of imaging parameters. Disk thicknesses (contrast) were determined from disk visibility. Effective dose to the phantom was also measured for technique combinations. The results indicated that using an anti-scatter grid and lowering x- ray tube potential improved the SNR significantly; however, the dose to the phantom also increased. An evaluation was performed to examine the clinical applicability of the observed improvements in SNR. Parameter adjustments that improved phantom SNRs by more than 50% resulted in perceived image quality improvements in the lung region of clinical mobile chest radiographs. Parameters that produced smaller improvements in SNR had no apparent effect on clinical image quality. Based on this study, it is recommended that a 3:1 grid be used for mobile chest radiography with CR in order to improve image quality. Using a higher kVp (+15 kVp) did not have a detrimental effect on image quality and offered a patient dose savings, including effective dose and breast dose. Higher kVp techniques should be considered when using a grid is not possible.
Kuiper, L M; Thijs, A; Smulders, Y M
2012-01-01
The advent of beamer projection of radiological images raises the issue of whether such projection compromises diagnostic accuracy. The purpose of this study was to evaluate whether beamer projection of chest X-rays is inferior to monitor display. We selected 53 chest X-rays with subtle abnormalities and 15 normal X-rays. The images were independently judged by a senior radiologist and a senior pulmonologist with a state-of-art computer monitor. We used their unanimous or consensus judgment as the reference test. Subsequently, four observers (one senior pulmonologist, one senior radiologist and one resident from each speciality) judged these X-rays on a standard clinical computer monitor and with beamer projection. We compared the number of correct results for each method. Overall, the sensitivity and specificity did not differ between monitor and beamer projection. Separate analyses in senior and junior examiners suggested that senior examiners had a moderate loss of diagnostic accuracy (8% lower sensitivity, pp<0.05, and 6% lower specificity, p=ns) associated with the use of beamer projection, whereas juniors showed similar performance on both imaging modalities. These initial data suggest that beamer projection may be associated with a small loss of diagnostic accuracy in specific subgroups of physicians. This finding illustrates the need for more extensive studies.
X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... Chernecky CC, Berger BJ. Radiography of skull, chest, and cervical spine - diagnostic. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. ...
The reduction methods of operator's radiation dose for portable dental X-ray machines.
Cho, Jeong-Yeon; Han, Won-Jeong
2012-08-01
This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.
Konrad, H; Schild, H; Weilemann, L S; Lorenz, J
1992-09-01
Serial chest x-rays of 23 ARDS patients, taken in an 24 hour interval, were retrospectively analysed. Radiographic patterns of ARDS were divided into five stages and were related to corresponding parameters of respiratory status. Characteristic findings on chest x-ray films occurred after a short latency period following the clinical onset of ARDS. There was a close relationship between the time of maximum radiographic changes and maximum loss of lung function. The progression through successive radiologic stages was in many cases accompanied by a significant deterioration of functional parameters. Distinction between survivors and non-survivors was achieved while considering maximum radiographic abnormalities. The results suggest significance of serial chest x-rays in diagnosis and course estimation of ARDS.
Golder, W; Weiner, G
2001-06-01
To contribute data on radiation exposure in static x-ray procedures and to compare them with anthropometric parameters. 121 chest x-rays and 100 lumbar spine examinations were carried out and the dose-area product (DAP) measured for each of the projections. Additionally, body height, body weight and the sagittal and transversal diameters of the examined regions were recorded. Dose measurements were statistically evaluated and the following data determined: Frequency distribution, median, 25%- and 75%-percentiles as well as correlations with sex, body weight and diameters. Median DAP was 13 (men: 16; women: 11) resp. 50 (62; 37) cGycm2 with pa resp lateral chest x-ray. Values were closely correlated with body weight (r = 0.704/0.659) and diameter of the chest (r = 0.657/0.579). Median DAP was 175 (239; 126) resp 531 (670; 361) cGycm2 with ap resp lateral lumbar spine examinations. Values were closely correlated with body weight (r = 0.678/0.666) and diameter of the abdomen (r = 0.664/0.658). DAP of chest x-rays and lumbar spine examinations is strongly influenced by the constitution of the patients. Men are nearly twice as largely exposed to radiation as women.
Radiation dose reduction in a neonatal intensive care unit in computed radiography.
Frayre, A S; Torres, P; Gaona, E; Rivera, T; Franco, J; Molina, N
2012-12-01
The purpose of this study was to evaluate the dose received by chest x-rays in neonatal care with thermoluminescent dosimetry and to determine the level of exposure where the quantum noise level does not affect the diagnostic image quality in order to reduce the dose to neonates. In pediatric radiology, especially the prematurely born children are highly sensitive to the radiation because of the highly mitotic state of their cells; in general, the sensitivity of a tissue to radiation is directly proportional to its rate of proliferation. The sample consisted of 208 neonatal chest x-rays of 12 neonates admitted and treated in a Neonatal Intensive Care Unit (NICU). All the neonates were preterm in the range of 28-34 weeks, with a mean of 30.8 weeks. Entrance Surface Doses (ESD) values for chest x-rays are higher than the DRL of 50 μGy proposed by the National Radiological Protection Board (NRPB). In order to reduce the dose to neonates, the optimum image quality was achieved by determining the level of ESD where level noise does not affect the diagnostic image quality. The optimum ESD was estimated for additional 20 chest x-rays increasing kVp and reducing mAs until quantum noise affects image quality. Copyright © 2012 Elsevier Ltd. All rights reserved.
Lilis, R; Ribak, J; Suzuki, Y; Penner, L; Bernstein, N; Selikoff, I J
1987-01-01
To assess the prevalence of non-malignant chest x ray abnormalities in cases of mesothelioma 184 cases of mesothelioma (72 pleural and 112 peritoneal) which had occurred in a cohort of asbestos insulation workers followed up since 1967 were studied. Chest x ray films of satisfactory quality, on which the presence or absence of non-malignant radiological changes indicating interstitial pulmonary fibrosis or pleural fibrosis or both, could be assessed with a high degree of certainty were available. In some cases (20% for pleural mesothelioma, 11.6% for peritoneal mesothelioma) non-malignant radiological changes were not radiologically detectable. Parenchymal interstitial fibrosis (small irregular opacities) only was found in a proportion of cases (25.4% of pleural mesotheliomas, 12.5% of peritoneal mesotheliomas). Pleural fibrosis only was detected in 17% of cases of pleural mesothelioma and 27% of cases of peritoneal mesothelioma. Most patients had both parenchymal and pleural fibrosis. Although these results tend to indicate that in peritoneal mesothelioma the proportion of pleural fibrosis is significantly higher, these findings might have been due to the fact that in most cases of pleural mesothelioma non-malignant changes were interpreted in one hemithorax only. In 46 cases (21 pleural, 25 peritoneal) in which sufficient lung tissue was available histopathology of lung parenchyma indicated the presence of interstitial fibrosis; in 20 (43.5%) of these the chest x ray film had been read as negative. Thus the absence of radiologically detectable small opacities on the chest x ray film does not exclude the existence of interstitial pulmonary fibrosis in cases of mesothelioma among insulation workers. With lower levels of exposure (such as in family contacts of asbestos workers) it is conceivable that mesothelioma might occur in the absence of interstitial pulmonary fibrosis. PMID:3606969
Morales, Maria-Aurora; Prediletto, Renato; Rossi, Giuseppe; Catapano, Giosuè; Lombardi, Massimo; Rovai, Daniele
2012-01-01
Objectives: The development of technologically advanced, expensive techniques has progressively reduced the value of chest X-ray in clinical practice for the assessment of left ventricular (LV) dilatation and dysfunction. Although controversial data are reported on the role of this widely available technique in cardiac assessment, it is known that the cardio-thoracic ratio is predictive of risk of progression in the NYHA Class, hospitalization, and outcome in patients with LV dysfunction. This study aimed to evaluate the reliability of the transverse diameter of heart shadow [TDH] by chest X-ray for detecting LV dilatation and dysfunction as compared to Magnetic Resonance Imaging (MRI) performed for different clinical reasons. Materials and Methods: In 101 patients, TDH was measured in digital chest X-ray and LV volumes and ejection fraction (EF) by MRI, both exams performed within 2 days. Results: A direct correlation between TDH and end-diastolic volumes (r = .75, P<0.0001) was reported. TDH cut-off values of 14.5 mm in females identified LV end-diastolic volumes >150 mL (sensitivity: 82%, specificity: 69%); in males a cut-off value of 15.5 mm identified LV end-diastolic volumes >210 mL (sensitivity: 84%; specificity: 72%). A negative relation was found between TDH and LVEF (r = -.54, P<0.0001). The above cut-off values of TDH discriminated patients with LV systolic dysfunction – LVEF <35% (sensitivity and specificity: 67% and 57% in females; 76% and 59% in males, respectively). Conclusions: Chest X-ray may still be considered a reliable technique in predicting LV dilatation by the accurate measurement of TDH as compared to cardiac MRI. Technologically advanced, expensive, and less available imaging techniques should be performed on the basis of sound clinical requests. PMID:22754739
Morales, Maria-Aurora; Prediletto, Renato; Rossi, Giuseppe; Catapano, Giosuè; Lombardi, Massimo; Rovai, Daniele
2012-01-01
The development of technologically advanced, expensive techniques has progressively reduced the value of chest X-ray in clinical practice for the assessment of left ventricular (LV) dilatation and dysfunction. Although controversial data are reported on the role of this widely available technique in cardiac assessment, it is known that the cardio-thoracic ratio is predictive of risk of progression in the NYHA Class, hospitalization, and outcome in patients with LV dysfunction. This study aimed to evaluate the reliability of the transverse diameter of heart shadow [TDH] by chest X-ray for detecting LV dilatation and dysfunction as compared to Magnetic Resonance Imaging (MRI) performed for different clinical reasons. In 101 patients, TDH was measured in digital chest X-ray and LV volumes and ejection fraction (EF) by MRI, both exams performed within 2 days. A direct correlation between TDH and end-diastolic volumes (r = .75, P<0.0001) was reported. TDH cut-off values of 14.5 mm in females identified LV end-diastolic volumes >150 mL (sensitivity: 82%, specificity: 69%); in males a cut-off value of 15.5 mm identified LV end-diastolic volumes >210 mL (sensitivity: 84%; specificity: 72%). A negative relation was found between TDH and LVEF (r = -.54, P<0.0001). The above cut-off values of TDH discriminated patients with LV systolic dysfunction - LVEF <35% (sensitivity and specificity: 67% and 57% in females; 76% and 59% in males, respectively). Chest X-ray may still be considered a reliable technique in predicting LV dilatation by the accurate measurement of TDH as compared to cardiac MRI. Technologically advanced, expensive, and less available imaging techniques should be performed on the basis of sound clinical requests.
Louie, Raphael J; Tonneson, Jennifer E; Gowarty, Minda; Goodney, Philip P; Barth, Richard J; Rosenkranz, Kari M
2015-11-01
Current National Comprehensive Cancer Network guidelines for breast cancer staging include pre-treatment complete blood count (CBC) and liver function tests (LFT) to screen for occult metastatic disease. To date, the relevance of these tests in detecting metastatic disease in asymptomatic women with early-stage breast cancer (Stage I/II) has not been demonstrated. Although chest x-rays are no longer recommended in the NCCN guidelines, many centers continue to include this imaging as part of their screening process. We aim to determine the clinical and financial impact of these labs and x-rays in the evaluation of early-stage breast cancer patients. A single institution IRB-approved retrospective chart review was conducted of patients with biopsy-proven invasive breast cancer treated from January 1, 2005–December 31, 2009. We collected patient demographics, clinical and pathologic staging, chest x-ray, CBC, and LFT results at the time of referral. Patients were stratified according to radiographic stage at the time of diagnosis. We obtained Medicare reimbursement fees for cost analysis. From 2005 to 2009, 1609 patients with biopsy-proven invasive breast cancer were treated at our institution. Of the 1082 patients with radiographic stage I/II disease, 27.3 % of patients had abnormal CBCs. No additional testing was performed to evaluate these abnormalities. In the early-stage population, 24.7 % of patients had elevated LFTs, resulting in 84 additional imaging studies. No metastatic disease was detected. The cost of CBC, LFTs and chest x-rays was $110.20 per patient, totaling $106,410.99. Additional tests prompted by abnormal results cost $58,143.30 over the five-year period. We found that pre-treatment CBCs, LFTs, and chest x-rays did not improve detection of occult metastatic disease but resulted in additional financial costs. Avoiding routine ordering of these tests would save the US healthcare system $25.7 million annually.
Patient exposure dose for chest and skull radiographies in Mazandaran hospitals.
Etemadinezhad, Siavash; Rahimi, Seyed Ali
2010-01-01
Radiographic techniques are essential methods of diagnosis, and their use has been increased, especially with the development of the new technologies. Inappropriate administration of these techniques may put both the patients and personnel at unnecessary risks. The objective of this research was to measure the skin dose of chest and skull radiographies used in Mazandaran hospitals and to compare these doses with national and international standards. In this cross-sectional study, six X-ray generators at six hospitals affiliated to Mazandaran University of Medical Sciences were included. One hundred and twenty patients referred to the radiology wards for radiographic examinations of chest and skull with normal body mass index (BMI) were selected (20 patients for each radiography unit). The generators were matched for mAs, kvp, type of amplifier sheets, and technical conditions as much as possible. Calibrated thermo luminescence dosimeters (TLD-USA, Lif-100) were used to measure the skin dose by placing them on the patients' back and the absorbed doses by TLDs were read by a TLD reader (model: Harshuu, TLD3500, Japan). The mean values of the skin dose were 0.51 mGray for posteroanterior (PA), chest X-ray (CXR), 3.36 mGray for lateral CXR, 7.25 mGray for anterroposterior (AP) or PA skull X-rays, and 7.59 mGray for lateral skull X-rays. The measured values were higher than the national and international standards. The results of this research revealed that the conditions of the X-ray generators should be monitored and modified periodically. Modifying the X-ray generators plus improving technicians' skills would, to some extent, reduce the radiation exposure of the patients.
2012-01-01
Background This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. Methods The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. Results The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Conclusions Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed. PMID:22691418
Kim, Hyung Min; So, Byung Hak; Jeong, Won Jung; Choi, Se Min; Park, Kyu Nam
2012-06-12
This study was designed to compare the effectiveness of using auscultation, pH measurements of gastric aspirates, and ultrasonography as physical examination methods to verify nasogastric tube(NGT) placement in emergency room patients with low consciousness who require NGT insertion. The study included 47 patients who were all over 18 years of age. In all patients, tube placement was verified by chest X-rays. Auscultation, pH analysis of gastric aspirates, and ultrasonography were conducted on each patient in random order. The mean patient age was 57.62 ± 17.24 years, and 28 males (59.6%) and 19 females (40.4%) were included. The NGT was inserted by an emergency room resident. For pH testing, gastric aspirates were dropped onto litmus paper, and the resulting color of the paper was compared with a reference table. Ultrasonography was performed by an emergency medicine specialist, and the chest X-ray examination was interpreted by a different emergency medicine specialist who did not conduct the ultrasonography test. The results of the auscultation, gastric aspirate pH, and ultrasonography examinations were compared with the results of the chest x-ray examination. The sensitivity and specificity were 100% and 33.3%, respectively, for auscultation and 86.4% and 66.7%, respectively, for ultrasonography. Kappa values were the highest for auscultation at 0.484 compared to chest x-rays, followed by 0.299 for ultrasonography and 0.444 for pH analysis of the gastric aspirate. The ultrasonography has a positive predictive value of 97.4% and a negative predictive value of 25%. Ultrasonography is useful for confirming the results of auscultation after NGT insertion among patients with low consciousness at an emergency center. When ultrasound findings suggest that the NGT placement is not gastric, additional chest X-ray should be performed.
Shibuya, Toru; Kato, Kyouichi; Eshima, Hidekazu; Sumi, Shinichirou; Kubo, Tadashi; Ishida, Hideki; Nakazawa, Yasuo
2012-01-01
In order to provide a precise radiography for diagnosis, it is required that we avoid radiography with defects by having enough evaluation. Conventionally, evaluation was performed only by observation of a radiological technologist (RT). The evaluation support system was developed for providing a high quality assurance without depending on RT observation only. The evaluation support system, called as the Image Quality Assurance Support System (IQASS), is characterized in that "image recognition technology" for the purpose of diagnostic radiography of chest and abdomen areas. The technique of the system used in this study. Of the 259 samples of posterior-anterior (AP) chest, lateral chest, and upright abdominal x-rays, the sensitivity and specificity was 93.1% and 91.8% in the chest AP, 93.3% and 93.6% in the chest lateral, and 95.0% and 93.8% in the upright abdominal x-rays. In the light of these results, it is suggested that AIQAS could be applied to practical usage for the RT.
An evaluation of the impact of digital imaging on radiographic practice and patient doses
NASA Astrophysics Data System (ADS)
Horrocks, J.; Violaki, K.
2015-09-01
Direct digital imaging technology was implemented in all areas in general and mobile radiology at Barts and the Royal London Hospitals in 2012. Evidence from recent radiation incident investigations indicates optimum exposure factors are not consistently selected, with the greater dynamic range of the digital detectors allowing sub-optimal practice. To investigate further patient dose data were extracted from the Radiology Information System for adult chest X-ray examinations in 2014, covering over 50,000 studies in the Trust. Chest X-ray examinations were selected as they are low dose but frequent examinations. The patient dose data were evaluated taking into account X-ray system type and detector performance measurements, and individual cases studies were used to highlight where practice can be improved.
Diagnosis of smear-negative pulmonary tuberculosis based on clinical signs in the Republic of Congo.
Linguissi, Laure Stella Ghoma; Vouvoungui, Christevy Jeannhey; Poulain, Pierre; Essassa, Gaston Bango; Kwedi, Sylvie; Ntoumi, Francine
2015-12-18
The diagnosis of pulmonary tuberculosis (PTB) and smear-negative pulmonary tuberculosis (SNPT) in resource-limited countries is often solely based on clinical signs, chest X-ray radiography and sputum smear microscopy. We investigated currently used methods for the routine diagnosis of SNPT in the Republic of Congo (RoC) among TB suspected patients. The specific case of HIV positive patients was also studied. A cross-sectional study was conducted at the anti-tuberculosis center (CAT) of Brazzaville, RoC. Tuberculosis suspects were examined for physical signs of TB. Clinical signs, results from sputum smear microscopy, tuberculin skin test (TST) and chest X-ray were recorded. Of the 772 enrolled participants, 372 were diagnosed PTB. Cough was a common symptom for PTB and no PTB patients. Pale skin, positive TST, weight loss and chest X-ray with abnormalities compatible with PTB (PTB-CXR) were significant indicators of PTB. Thirty-six percent of PTB patients were diagnosed SNPT. This category of patients presented less persistent cough and less PTB-CXR. Anorexia and asthenia were significant indicators of SNPT. In the case of HIV+ patients, 57% were SNPT with anorexia, asthenia and shorter cough being strong indicators of SNPT. Chest X-ray abnormalities, weight loss, pale skin and positive TST were significant indicators of PTB. Anorexia and asthenia showed good diagnostic performance for SNPT, which deserve to be recommended as index indicators of SNPT diagnosis. Duration of cough is also a relevant indicator, especially for HIV+ patients.
Albers, C E; Haefeli, P C; Zimmermann, H; de Moya, M; Exadaktylos, A K
2013-05-01
Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our findings. Copyright © 2012 Elsevier Ltd. All rights reserved.
29 CFR 1910.1018 - Inorganic arsenic.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-anterior chest x-ray; (B) A nasal and skin examination; and (C) Other examinations which the physician... results or references to that information; (C) The initial X-ray; (D) The X-rays for the most recent 5 years; and (E) Any X-rays with a demonstrated abnormality and all subsequent X-rays; (iv) The employer...
Xu, Tong; Shikhaliev, Polad M; Berenji, Gholam R; Tehranzadeh, Jamshid; Saremi, Farhood; Molloi, Sabee
2004-04-01
To evaluate the feasibility and performance of an x-ray beam equalization system for chest radiography using anthropomorphic phantoms. Area beam equalization involves the process of the initial unequalized image acquisition, attenuator thickness calculation, mask generation using a 16 x 16 piston array, and final equalized image acquisition. Chest radiographs of three different anthropomorphic phantoms were acquired with no beam equalization and equalization levels of 4.8, 11.3, and 21. Six radiologists evaluated the images by scoring them from 1-5 using 13 different criteria. The dose was calculated using the known attenuator material thickness and the mAs of the x-ray tube. The visibility of anatomic structures in the under-penetrated regions of the chest radiographs was shown to be significantly (P < .01) improved after beam equalization. An equalization level of 4.8 provided most of the improvements with moderate increases in patient dose and tube loading. Higher levels of beam equalization did not show much improvement in the visibility of anatomic structures in the under-penetrated regions. A moderate level of x-ray beam equalization in chest radiography is superior to both conventional radiographs and radiographs with high levels of beam equalization. X-ray beam equalization can significantly improve the visibility of anatomic structures in the under-penetrated regions while maintaining good image quality in the lung region.
NASA Astrophysics Data System (ADS)
Falkensammer, Peter; Soegner, Peter I.; zur Nedden, Dieter
2002-05-01
The integration of RIS-PACS systems in radiology units are intended to reduce time consumption in radiology workflow and thus to increase radiologist productivity. Along with the RIS-PACS integration at the University Hospital Innsbruck we analyzed workflow from patient admission to release of final reports before implementation. The follow up study after six months of the implementation is currently in work. In this study we compared chest to skeletal x-ray examinations in 969 patients before the implementation. Drawing the admission-to-release-of-final-report period showed a two-peak diagram with the first peak corresponding to a release of final results on the same day and the second peak to a release on the following day. In the chest x-ray group, 57% were released the same day (mean value 4:02 hours) and 43% the next day (mean value 21:47 hours). Looking at the skeletal x-rays 40% were released the same day (mean value 3:58 hours) and 60% were released the next day (mean value 21:05 hours). Summarizing the results we should say, that the average chest x-ray requires less time than an skeletal x-ray, due to the fact that a greater percentage of reports is released the same day. The most important result is, that the most time consuming workstep is the exchange of data media between radiologist and secretary with at least 5 hours.
Multilingual Information Retrieval in Thoracic Radiology: Feasibility Study
Castilla, André Coutinho; Furuie, Sérgio Shiguemi; Mendonça, Eneida A.
2014-01-01
Most of essential information contained on Electronic Medical Record is stored as text, imposing several difficulties on automated data extraction and retrieval. Natural language processing is an approach that can unlock clinical information from free texts. The proposed methodology uses the specialized natural language processor MEDLEE developed for English language. To use this processor on Portuguese medical texts, chest x-ray reports were Machine Translated into English. The result of serial coupling of MT an NLP is tagged text which needs further investigation for extracting clinical findings. The objective of this experiment was to investigate normal reports and reports with device description on a set of 165 chest x-ray reports. We obtained sensitivity and specificity of 1 and 0.71 for the first condition and 0.97 and 0.97 for the second respectively. The reference was formed by the opinion of two radiologists. The results of this experiment indicate the viability of extracting clinical findings from chest x-ray reports through coupling MT and NLP. PMID:17911745
NASA Astrophysics Data System (ADS)
Lieberman, Robert; Kwong, Heston; Liu, Brent; Huang, H. K.
2009-02-01
The chest x-ray radiological features of tuberculosis patients are well documented, and the radiological features that change in response to successful pharmaceutical therapy can be followed with longitudinal studies over time. The patients can also be classified as either responsive or resistant to pharmaceutical therapy based on clinical improvement. We have retrospectively collected time series chest x-ray images of 200 patients diagnosed with tuberculosis receiving the standard pharmaceutical treatment. Computer algorithms can be created to utilize image texture features to assess the temporal changes in the chest x-rays of the tuberculosis patients. This methodology provides a framework for a computer-assisted detection (CAD) system that may provide physicians with the ability to detect poor treatment response earlier in pharmaceutical therapy. Early detection allows physicians to respond with more timely treatment alternatives and improved outcomes. Such a system has the potential to increase treatment efficacy for millions of patients each year.
Spontaneous pneumomediastinum: A rare complication of methamphetamine use.
Albanese, Jessica; Gross, Cole; Azab, Mohamed; Mahalean, Sinziana; Makar, Ranjit
2017-01-01
To present an unusual case of spontaneous pneumomediastinum subsequent to recreational amphetamine use. A young African American adult male was admitted to internal medicine service for treatment of rhabdomyolysis secondary to methamphetamine use. On admission, he was complaining of chest pain in addition to nausea and generalized muscle aches. By his second hospital day, chest pain had resolved yet physical exam demonstrated crepitation of the anterior chest and left axilla. Portable chest x-ray revealed subcutaneous emphysema in addition to pneumomediastinum. Spontaneous pneumomediastinum is a rare complication of amphetamine use that is often associated with subcutaneous emphysema and can be diagnosed with chest x-ray. Management is conservative, with observation, pain control, and supplemental oxygen as needed.
Legionnaire's pneumonia: is there really an interstitial disease?
Godet, C; Frat, J P; Le Moal, G; Roblot, F; Michalakis, G; Cabon, E; Tasu, J P
2007-01-01
Legionella pneumonia is usually classified as "atypical pneumonia", which suggests a predominance of interstitial patterns in chest X-rays. Based on a selection of recent clinical cases and a brief review of the literature, the aim of the study is to clarify, how far the actual radiological findings would be consistent with these expectations. A retrospective analysis of 18 epidemic personal cases and a review of the literature data were performed to describe the chest X-ray findings of Legionella pneumophila (LP) community acquired pneumonia. X-ray review was performed simultaneously and in consensus by two radiologists (J.P.T., E.C.) and a physician (C.G.). From our series, 17 patients had an abnormal chest X-ray on admission. Among these pathological X-ray cases, infiltrates were more often confluent (n=16), or patchy (n=7), rather than interstitial (n=1). Fifteen patients had infiltrates involving the lower lung fields. Bilateral distribution of abnormalities and pleural effusion were each observed in three cases. Radiological findings deteriorated between the second and seventh days following admission, particularly in the form of patchy infiltrates with pleural effusion. The review of the literature is consistent with these findings, by reporting prevalent confluent or patchy infiltrates. These findings are consistent with the physiopathological particularity of this affection and incite us to avoid the classification "atypical pneumonia" in radiologic terminology. This term is more appropriate for clinical and microbiological use.
Omar, Hesham R; Mangar, Devanand; Khetarpal, Suneel; Shapiro, David H; Kolla, Jaya; Rashad, Rania; Helal, Engy; Camporesi, Enrico M
2011-09-27
Pneumothorax is a common complication following blunt chest wall trauma. In these patients, because of the restrictions regarding immobilization of the cervical spine, Anteroposterior (AP) chest radiograph is usually the most feasible initial study which is not as sensitive as the erect chest X-ray or CT chest for detection of a pneumothorax. We will present 3 case reports which serve for better understanding of the entity of occult pneumothorax. The first case is an example of a true occult pneumothorax where an initial AP chest X-ray revealed no evidence of pneumothorax and a CT chest immediately performed revealed evidence of pneumothorax. The second case represents an example of a missed rather than a truly occult pneumothorax where the initial chest radiograph revealed clues suggesting the presence of pneumothorax which were missed by the reading radiologist. The third case emphasizes the fact that "occult pneumothorax is predictable". The presence of subcutaneous emphesema and pulmonary contusion should call for further imaging with CT chest to rule out pneumothorax. Thoracic CT scan is therefore the "gold standard" for early detection of a pneumothorax in trauma patients. This report aims to sensitize readers to the entity of occult pneumothorax and create awareness among intensivists and ER physicians regarding the proper diagnosis and management.
Development of a stationary chest tomosynthesis system using carbon nanotube x-ray source array
NASA Astrophysics Data System (ADS)
Shan, Jing
X-ray imaging system has shown its usefulness for providing quick and easy access of imaging in both clinic settings and emergency situations. It greatly improves the workflow in hospitals. However, the conventional radiography systems, lacks 3D information in the images. The tissue overlapping issue in the 2D projection image result in low sensitivity and specificity. Both computed tomography and digital tomosynthesis, the two conventional 3D imaging modalities, requires a complex gantry to mechanically translate the x-ray source to various positions. Over the past decade, our research group has developed a carbon nanotube (CNT) based x-ray source technology. The CNT x-ray sources allows compacting multiple x-ray sources into a single x-ray tube. Each individual x-ray source in the source array can be electronically switched. This technology allows development of stationary tomographic imaging modalities without any complex mechanical gantries. The goal of this work is to develop a stationary digital chest tomosynthesis (s-DCT) system, and implement it for a clinical trial. The feasibility of s-DCT was investigated. It is found that the CNT source array can provide sufficient x-ray output for chest imaging. Phantom images have shown comparable image qualities as conventional DCT. The s-DBT system was then used to study the effects of source array configurations and tomosynthesis image quality, and the feasibility of a physiological gated s-DCT. Using physical measures for spatial resolution, the 2D source configuration was shown to have improved depth resolution and comparable in-plane resolution. The prospective gated tomosynthesis images have shown substantially reduction of image blur associated with lung motions. The system was also used to investigate the feasibility of using s-DCT as a diagnosis and monitoring tools for cystic fibrosis patients. A new scatter reduction methods for s-DCT was also studied. Finally, a s-DCT system was constructed by retrofitting the source array to a Carestream digital radiography system. The system passed the electrical and radiation safety tests, and was installed in Marsico Hall. The patient trial started in March of 2015, and the first patient was successfully imaged.
ERIC Educational Resources Information Center
Litchfield, Damien; Ball, Linden J.; Donovan, Tim; Manning, David J.; Crawford, Trevor
2010-01-01
Double reading of chest x-rays is often used to ensure that fewer abnormalities are missed, but very little is known about how the search behavior of others affects observer performance. A series of experiments investigated whether radiographers benefit from knowing where another person looked for pulmonary nodules, and whether the expertise of…
Tschauner, Sebastian; Marterer, Robert; Gübitz, Michael; Kalmar, Peter I; Talakic, Emina; Weissensteiner, Sabine; Sorantin, Erich
2016-02-01
Accurate collimation helps to reduce unnecessary irradiation and improves radiographic image quality, which is especially important in the radiosensitive paediatric population. For AP/PA chest radiographs in children, a minimal field size (MinFS) from "just above the lung apices" to "T12/L1" with age-dependent tolerance is suggested by the 1996 European Commission (EC) guidelines, which were examined qualitatively and quantitatively at a paediatric radiology division. Five hundred ninety-eight unprocessed chest X-rays (45% boys, 55% girls; mean age 3.9 years, range 0-18 years) were analysed with a self-developed tool. Qualitative standards were assessed based on the EC guidelines, as well as the overexposed field size and needlessly irradiated tissue compared to the MinFS. While qualitative guideline recommendations were satisfied, mean overexposure of +45.1 ± 18.9% (range +10.2% to +107.9%) and tissue overexposure of +33.3 ± 13.3% were found. Only 4% (26/598) of the examined X-rays completely fulfilled the EC guidelines. This study presents a new chest radiography quality control tool which allows assessment of field sizes, distances, overexposures and quality parameters based on the EC guidelines. Utilising this tool, we detected inadequate field sizes, inspiration depths, and patient positioning. Furthermore, some debatable EC guideline aspects were revealed. • European Guidelines on X-ray quality recommend exposed field sizes for common examinations. • The major failing in paediatric radiographic imaging techniques is inappropriate field size. • Optimal handling of radiographic units can reduce radiation exposure to paediatric patients. • Constant quality control helps ensure optimal chest radiographic image acquisition in children.
Skinner, Sarah
2015-08-01
Thoracic imaging is commonly ordered in general practice. Guidelines exist for ordering thoracic imaging but few are specific for general practice. This article summarises current indications for imaging the thorax with chest X-ray and computed tomography. A simple frame-work for interpretation of the chest X-ray, suitable for trainees and practitioners providing primary care imaging in rural and remote locations, is presented. Interpretation of thoracic imaging is best done using a systematic approach. Radiological investigation is not warranted in un-complicated upper respiratory tract infections or asthma, minor trauma or acute-on-chronic chest pain.
Safari, Saeed; Radfar, Fatemeh; Baratloo, Alireza
2018-05-01
This study aimed to compare the diagnostic accuracy of NEXUS chest and Thoracic Injury Rule out criteria (TIRC) models in predicting the risk of intra-thoracic injuries following blunt multiple trauma. In this diagnostic accuracy study, using the 2 mentioned models, blunt multiple trauma patients over the age of 15 years presenting to emergency department were screened regarding the presence of intra-thoracic injuries that are detectable via chest x-ray and screening performance characteristics of the models were compared. In this study, 3118 patients with the mean (SD) age of 37.4 (16.9) years were studied (57.4% male). Based on TIRC and NEXUS chest, respectively, 1340 (43%) and 1417 (45.4%) patients were deemed in need of radiography performance. Sensitivity, specificity, and positive and negative predictive values of TIRC were 98.95%, 62.70%, 21.19% and 99.83%. These values were 98.61%, 59.94%, 19.97% and 99.76%, for NEXUS chest, respectively. Accuracy of TIRC and NEXUS chest models were 66.04 (95% CI: 64.34-67.70) and 63.50 (95% CI: 61.78-65.19), respectively. TIRC and NEXUS chest models have proper and similar sensitivity in prediction of blunt traumatic intra-thoracic injuries that are detectable via chest x-ray. However, TIRC had a significantly higher specificity in this regard. Copyright © 2018 Elsevier Ltd. All rights reserved.
Winkens, Ron A. G.; Guldemond, Frank I.; Hoppener, Paul F. H. M.; Kragten, Hans A.; Knottnerus, J. Andre
2013-01-01
Objectives. Doctors all over the world consider a pectus excavatum usually as an incidental finding. There is some evidence suggesting that a pectus excavatum may cause symptoms in the elderly. It is not known how often a pectus excavatum occurs and how strong the relation is with symptoms. Methods. In hospitals and general practice data, we searched for evidence of a connection between cardiac symptoms and the presence of a pectus excavatum in a retrospective survey among patients in whom a pectus excavatum was found in a chest X-ray. In radiology reports, we searched for “pectus excavat∗ ” in almost 160000 chest X-rays. The identified X-rays were reviewed by 2 radiologists. Reported symptoms were combined to a severity sum score and the relation with pectus excavatum was assessed through logistic regression. Results. Pectus excavatum was found in 1 to 2 per 1000 chest X-rays. In 32% of patients (N = 117), we found symptoms that might reflect the presence of symptomatic pectus excavatum. We found a significant relation between the SPES sum score and the radiological level of pectus excavatum. Conclusions. A pectus excavatum found when examining the patient should not be neglected and should be considered as a possible explanation for symptoms like dyspnoea, fatigue, or palpitations. PMID:24982857
The National Lung Screening Trial (NLST) | Division of Cancer Prevention
The National Lung Screening Trial (NLST) compared two ways of detecting lung cancer: low-dose helical computed tomography (CT) and standard chest X-ray. Both chest X-rays and low-dose helical CT scans have been used to find lung cancer early, but the effects of these screening techniques on lung cancer mortality rates had not been determined. NLST enrolled 53,454 current or
[Possibile application of X-ray and high resolution CT in pneumoconiosis management].
Vlasov, V G; Laptev, V Ia; Logvinenko, I I; Smirnova, E L; Brovchenko, E P; Mironova, M V
2011-01-01
The article covers results of clinical and roentgenologic data analysis. The data were obtained in the study that covered 447 pneumoconiosis patients, 75 of which were subjected to high resolution CT. If compared to chest X-ray, high resolution CT helps more precise forecast of further course in pneumoconiosis.
Chang, Li-Chun; Hung, Li-Ling; Chou, Yu-Wen; Ling, Li-May
2007-03-01
The purpose of this study was to investigate knowledge, perceptions of tuberculosis (TB) and intent to receive chest X-ray screening among indigenous (Taiwanese of ethnic Malayo-Polynesian descent) nursing students in Taiwan. A convenience sample was chosen from an technical institute in northern Taiwan that maintained admission quotas and provided scholarships for indigenous students. This school had over 150 classes and around 7,000 students, about 20% -25% of whom were ethnically indigenous. A power analysis based on a pilot study showed that a large effect size required a minimum sample of 485. To attain this number, 50 classes from years one through five were randomly selected based on an expected sampling of 20 students per classroom. In all, 1,000 questionnaires were distributed and 865 returned, for a response rate of 86.5%. A cross-sectional study design was used, and this study was run between the months of February and June 2003. Survey responses were self-reported in two questionnaires that gathered information on respondent knowledge and perceptions regarding TB and intent to take chest X-ray tests. Study results showed a moderate level of general knowledge about TB, misunderstandings regarding transmission vectors, and low perceptions regarding susceptibility. The knowledge score was associated with perceived benefits and barriers to preventing TB. Different places of residence influenced perceived barriers to preventing and treating TB. Age was negatively associated with the perceived benefits of receiving a chest X-ray exam for TB. Indigenous nursing students with higher perceptions of susceptibility and severity and lower perception of barriers on preventing TB had a higher level of intent to take the X-ray exam. Nursing schools must address the subject of TB in-depth and design age-specific curricula that incorporate multifaceted strategies for different students. Additionally, health educators should design health education programs targeted to dispel misconceptions and improve both knowledge and levels of awareness of tuberculosis among the indigenous population in order to enhance their willingness and ability to detect TB.
Giacomelli, Irai Luis; Schuhmacher Neto, Roberto; Marchiori, Edson; Pereira, Marisa; Hochhegger, Bruno
2018-04-01
The objective of this systematic review was to select articles including chest X-ray or chest CT findings in patients who developed pulmonary tuberculosis following solid organ transplantation (lung, kidney, or liver). The following search terms were used: "tuberculosis"; "transplants"; "transplantation"; "mycobacterium"; and "lung". The databases used in this review were PubMed and the Brazilian Biblioteca Virtual em Saúde (Virtual Health Library). We selected articles in English, Portuguese, or Spanish, regardless of the year of publication, that met the selection criteria in their title, abstract, or body of text. Articles with no data on chest CT or chest X-ray findings were excluded, as were those not related to solid organ transplantation or pulmonary tuberculosis. We selected 29 articles involving a collective total of 219 patients. The largest samples were in studies conducted in Brazil and South Korea (78 and 35 patients, respectively). The imaging findings were subdivided into five common patterns. The imaging findings varied depending on the transplanted organ in these patients. In liver and lung transplant recipients, the most common pattern was the classic one for pulmonary tuberculosis (cavitation and "tree-in-bud" nodules), which is similar to the findings for pulmonary tuberculosis in the general population. The proportion of cases showing a miliary pattern and lymph node enlargement, which is most similar to the pattern seen in patients coinfected with tuberculosis and HIV, was highest among the kidney transplant recipients. Further studies evaluating clinical data, such as immunosuppression regimens, are needed in order to improve understanding of the distribution of these imaging patterns in this population.
[Lateral chest X-rays. Radiographic anatomy].
García Villafañe, C; Pedrosa, C S
2014-01-01
Lateral chest views constitute an essential part of chest X-ray examinations, so it is fundamental to know the anatomy on these images and to be able to detect the variations manifested on these images in different diseases. The aim of this article is to review the normal anatomy and main normal variants seen on lateral chest views. For teaching purposes, we divide the thorax into different spaces and analyze each in an orderly way, especially emphasizing the anatomic details that are most helpful for locating lesions that have already been detected in the posteroanterior view or for detecting lesions that can be missed in the posteroanterior view. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Effectiveness of electrocardiographic guidance in CVAD tip placement.
Walker, Graham; Chan, Raymond J; Alexandrou, Evan; Webster, Joan; Rickard, Claire
International standard practice for the correct confirmation of the central venous access device is the chest X-ray. The intracavitary electrocardiogram-based insertion method is radiation-free, and allows real-time placement verification, providing immediate treatment and reduced requirement for post-procedural repositioning. Relevant databases were searched for prospective randomised controlled trials (RCTs) or quasi RCTs that compared the effectiveness of electrocardiogram-guided catheter tip positioning with placement using surface-anatomy-guided insertion plus chest X-ray confirmation. The primary outcome was accurate catheter tip placement. Secondary outcomes included complications, patient satisfaction and costs. Five studies involving 729 participants were included. Electrocardiogram-guided insertion was more accurate than surface anatomy guided insertion (odds ratio: 8.3; 95% confidence interval (CI) 1.38; 50.07; p=0.02). There was a lack of reporting on complications, patient satisfaction and costs. The evidence suggests that intracavitary electrocardiogram-based positioning is superior to surface-anatomy-guided positioning of central venous access devices, leading to significantly more successful placements. This technique could potentially remove the requirement for post-procedural chest X-ray, especially during peripherally inserted central catheter (PICC) line insertion.
Flat panel detectors--closing the (digital) gap in chest and skeletal radiology.
Reiff, K J
1999-08-01
In the radiological department today the majority of all X-ray procedures on chest and skeletal radiography is performed with classical film-screen-systems. Using digital luminescence radiography (DLR or CR, which stands for Computed Radiography) as a technique has shown a way to replace this 100-year-old procedure of doing general radiography work by acquiring the X-rays digitally via phosphor screens, but this approach has faced criticism from lots of radiologists world wide and therefore has not been widely accepted except in the intensive care environment. A new technology is now rising based on the use of so called flat panel X-ray (FD) detectors. Semi-conducting material detects the X-rays in digital form directly and creates an instantaneous image for display, distribution and diagnosis. This ability combined with a large field of view and compared to existing methods--excellent detective quantum efficiency represents a revolutionary step for chest and skeletal radiography and will put basic X-ray-work back into the focus of radiological solutions. This paper will explain the basic technology of flat panel detectors, possible system solutions based on this new technology, aspects of the user interface influencing the system utilization and versatility as well as the possibility to redefine the patient examination process for chest and skeletal radiography. Furthermore the author discusses limitations for the first released systems, upgrades for the installed base and possible scenarios for the future, e.g. fluoroscopy or angiography application.
Szeto, Timothy C; Webster, Christie Ann; Koprinarov, Ivaylo; Rowlands, J A
2008-03-01
Digital x-ray radiographic systems are desirable as they offer high quality images which can be processed, transferred, and stored without secondary steps. However, current clinical systems are extraordinarily expensive in comparison to film-based systems. Thus, there is a need for an economical digital imaging system for general radiology. The x-ray light valve (XLV) is a novel digital x-ray detector concept with the potential for high image quality and low cost. The XLV is comprised of a photoconductive detector layer and liquid crystal (LC) cell physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected at the surface of the photoconductor, causing a change in the reflective properties of the LC cell. The visible image so formed can subsequently be digitized with an optical scanner. By choosing the properties of the LC cell in combination with the appropriate photoconductor thickness and bias potentials, the XLV can be optimized for various diagnostic imaging tasks. Specifically for chest radiography, we identified three potentially practical reflective cell designs by selecting from those commonly used in LC display technology. The relationship between reflectance and x-ray exposure (i.e., the characteristic curve) was determined for all three cells using a theoretical model. The results indicate that the reflective electrically controlled birefringence (r-ECB) cell is the preferred choice for chest radiography, provided that the characteristic curve can be shifted towards lower exposures. The feasibility of the shift of the characteristic curve is shown experimentally. The experimental results thus demonstrate that an XLV based on the r-ECB cell design exhibits a characteristic curve suitable for chest radiography.
Military Interoperable Digital Hospital Testbed
2012-07-01
Subject outcome measures include blood pressure, waist circumference, weight, body mass index (BMI), body fat, HDL cholesterol, triglycerides , glucose ...master patient index (MPI), 625 duplicate chest x-rays and CT scans of the head between sending and receiving institution (taken within 0-7 days) were... Index (MPI) software. The report included chest x-rays (CPT 71010 and 71020) and CT scans of the head (CPT 70450) for the stated time periods. The
Is it adequate to carry out a chest-CT in patients with mild-moderate chest trauma?
García de Pereda de Blas, V; Carreras Aja, M; Carbajo Azabal, S; Arana-Arri, E
2017-10-12
Mild-moderate blunt chest trauma is defined as a blunt chest trauma that is not caused by a high-energy mechanism, causing thoracic tenderness with or without rib fractures and that has no immediate life-threatening consequences for the patient. It is a frequent clinical situation in the emergency department. The most common radiological techniques that are used in this context are chest X-ray and thoracic computed tomography (CT). The CT scan is set as the gold standard. However, there are no current clinical-radiological guidelines that establish the adequacy of the requests of the CT scan. Therefore, we decided to search for evidence-based recommendations to improve the adequacy of the chest X-ray and CT scan in our daily practice in order to reduce the costs and avoid unnecessary radiation exposure. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Tam, Michael M K
2005-01-01
At present, CT scan is the gold standard for detecting occult traumatic pneumothorax not apparent on supine chest X-ray radiograph. Recently there were suggestions to expand focused assessment with sonography for trauma (FAST) to include thoracic ultrasound for detecting pneumothorax. The aim of the present study is to determine the incidence of occult pneumothorax (as shown by CT) in the subgroup of trauma patients undergoing FAST. Review of all trauma patients with FAST done from 1 June 2001 to 31 October 2002. Incidence of occult pneumothorax as diagnosed by CT was determined. Patients were not counted as having true occult pneumothorax if they had chest drains inserted before arrival or imaging studies. Selected clinical findings were tested for association with occult pneumothorax. In total, 143 patients underwent FAST, of whom 137 (95.8%) had chest X-ray examination performed. Of the 137 patients 59 required CT abdomen and/or thorax. Occult pneumothorax was found in three patients (2.1%). A history of thorax and/or abdominal injury plus one or more of: (i) mechanisms potentially causing major trauma; (ii) abnormal chest examination; and (iii) chest X-ray radiograph abnormality in the absence of pneumothorax, was significantly associated with the presence of occult pneumothorax (P = 0.03, Fisher's exact test; sensitivity: 100%; specificity: 71%; likelihood ratio: 3.42). The incidence of occult pneumothorax in the subgroup of trauma patients undergoing FAST is low. It implies that routine screening for its presence by adding thoracic ultrasound to FAST is unnecessary. Identifying those at risk of occult pneumothorax for further investigation appeared feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, J.L.; Krieger, M.J.
This paper is about the economic evaluation of diagnostic procedures. The issue of economic evaluation is explored in the context of four common diagnostic X-ray procedures: the chest X-ray, the skull X-ray, the barium enema study, and the excretory urogram. The paper is divided into two parts. The first part summarizes the different evaluative models underlying studies of the four diagnostic X-ray procedures and to lay out the strengths and weaknesses of each method. The second part contains four separate chapters summarizing what is known about the utilization, costs, risks, and benefits of each procedure, with particular emphasis on themore » evaluative methods employed.« less
PATIENT RADIATION DOSE FROM CHEST X-RAY EXAMINATIONS IN THE WEST BANK-PALESTINE.
Lahham, Adnan; Issa, Ahlam; ALMasri, Hussein
2018-02-01
Radiation doses to patients resulting from chest X-ray examinations were evaluated in four medical centers in the West Bank and East Jerusalem-Palestine. Absorbed organ and effective doses were calculated for a total of 428 adult male and female patients by using commercially available Monte Carlo based softwares; CALDOSE-X5 and PCXMC-2.0, and hermaphrodite mathematical adult phantoms. Patients were selected randomly from medical records in the time period from November 2014 to February 2015. A database of surveyed patients and exposure factors has been established and includes: patient's height, weight, age, gender, X-ray tube voltage, electric current (mAs), examination projection (anterior posterior (AP), posterior anterior (PA), lateral), X-ray tube filtration thickness in each X-ray equipment, anode angle, focus to skin distance and X-ray beam size. The average absorbed doses in the whole body from different projections were: 0.06, 0.07 and 0.11 mGy from AP, PA and lateral projections, respectively. The average effective dose for all surveyed patients was 0.14 mSv for all chest X-ray examinations and projections in the four investigated medical centers. The effect of projection geometry was also investigated. The average effective doses for AP, PA and lateral projections were 0.14, 0.07 and 0.22 mSv, respectively. The collective effective dose estimated for the exposed population was ~60 man-mSv. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Interpretation of bedside chest X-rays in the ICU: is the radiologist still needed?
Martini, Katharina; Ganter, Christoph; Maggiorini, Marco; Winklehner, Anna; Leupi-Skibinski, Katarzyna E; Frauenfelder, Thomas; Nguyen-Kim, Thi Dan Linh
2015-01-01
To compare diagnostic accuracy of intensivists to radiologists in reading bedside chest X-rays. In a retrospective trial, 33 bedside chest X-rays were evaluated by five radiologists and five intensivists with different experience. Images were evaluated for devices and lung pathologies. Interobserver agreement and diagnostic accuracy were calculated. Computed tomography served as reference standard. Seniors had higher diagnostic accuracy than residents (mean-ExpB(Senior)=1.456; mean-ExpB(Resident)=1.635). Interobserver agreement for installations was more homogenously distributed between radiologists compared to intensivists (ExpB(Rad)=1.204-1.672; ExpB(Int)=1.005-2.368). Seniors had comparable diagnostic accuracy. No significant difference in diagnostic performance was seen between seniors of both disciplines, whereas the resident intensivists might still benefit from an interdisciplinary dialogue. Copyright © 2015 Elsevier Inc. All rights reserved.
Chapman, Brandon C; Overbey, Douglas M; Tesfalidet, Feven; Schramm, Kristofer; Stovall, Robert T; French, Andrew; Johnson, Jeffrey L; Burlew, Clay C; Barnett, Carlton; Moore, Ernest E; Pieracci, Fredric M
2016-12-01
Chest CT is more sensitive than a chest X-ray (CXR) in diagnosing rib fractures; however, the clinical significance of these fractures remains unclear. The purpose of this study was to determine the added diagnostic use of chest CT performed after CXR in patients with either known or suspected rib fractures secondary to blunt trauma. Retrospective cohort study of blunt trauma patients with rib fractures at a level I trauma center that had both a CXR and a CT chest. The CT finding of ≥ 3 additional fractures in patients with ≤ 3 rib fractures on CXR was considered clinically meaningful. Student's t-test and chi-square analysis were used for comparison. We identified 499 patients with rib fractures: 93 (18.6%) had CXR only, 7 (1.4%) had chest CT only, and 399 (79.9%) had both CXR and chest CT. Among these 399 patients, a total of 1,969 rib fractures were identified: 1,467 (74.5%) were missed by CXR. The median number of additional fractures identified by CT was 3 (range, 4 - 15). Of 212 (53.1%) patients with a clinically meaningful increase in the number of fractures, 68 patients underwent one or more clinical interventions: 36 SICU admissions, 20 pain catheter placements, 23 epidural placements, and 3 SSRF. Additionally, 70 patients had a chest tube placed for retained hemothorax or occult pneumothorax. Overall, 138 patients (34.5%) had a change in clinical management based upon CT chest. The chest X-ray missed ~75% of rib fractures seen on chest CT. Although patients with a clinical meaningful increase in the number of rib fractures were more likely to be admitted to the intensive care unit, there was no associated improvement in pulmonary outcomes.
Borowska-Solonynko, A
The paper presents two case reports of living victims, in which imaging studies of the chest conducted at a medical facility were an essential part of the medico-legal opinion. The first case was that of a young male hospitalized due to CT evidence of bilateral rib fractions, who claimed to have been assaulted by police officers. The other case was that of a six week old baby hospitalized due to chest X-ray evidence of right hand side rib fractions. The chest X-ray was performed due to one bruise found on the baby's forehead and two small bruises on the back, which gave rise to suspicions of child abuse. In both cases, expert witnesses in radiology definitively excluded the presence of any fractures. These cases indicate that a new assessment of imaging studies contained in medical records is needed. Expert opinions based solely on the description of imaging studies may result in grave consequences.
Introducing guidelines into clinical practice.
Fowkes, F G; Roberts, C J
1984-04-01
The impetus for guidelines of practice has been accelerated by a worldwide trend towards insurance based systems of health care. In the past it has been the tradition for the clinician to order all the diagnostic procedures that conceivably might help to clarify what is wrong with a patient, or what course of treatment should be followed. This traditional view ignores the stubborn economic reality that resources are finite and that it is no longer possible to be both endlessly generous and continually fair. Making judgements about the need for, and value of, services now forms an important part of coping with this problem. Clinical practice has to strive to be as safe as possible and to produce a given benefit at a socially acceptable cost. Guidelines are recommendations, preferably developed by clinicians themselves, which describe how and when individual clinical activities should be offered in order to achieve these objectives. Utilisation review of current practice is a valuable source of information for the development of guidelines. In the United Kingdom the Royal College of Radiologists attempted to do this in connection with the use of pre-operative chest X-rays. In 1979 they published the findings of a multicentre review of 10,619 consecutive cases of elective non-cardiopulmonary surgery undertaken in 8 centres throughout the United Kingdom. Substantial variations were found in national practice. Use of pre-operative chest X-rays varied from 11.5% of patients in one centre to 54.2% of patients in another centre. The study also found that the chest X-ray report did not seem to have much influence on the decision to operate nor on the decision to use inhalation anaesthesia. The College study failed to find "any evidence at all for the effectiveness of pre-operative chest X-ray when used routinely" and it was estimated that even if the procedure was 10% effective the costs of avoiding one death would be approximately 1 million pounds. These findings provided the impetus for the College to develop guidelines for the use of pre-operative chest X-rays in hospitals in the United Kingdom. Creating a change in clinical practice through the introduction of guidelines is a three stage process: Stage I: introducing the idea of a change in practice. Stage II: introduction of guidelines into clinical practice. Stage III: sustained implementation of guidelines in clinical practice.(ABSTRACT TRUNCATED AT 400 WORDS)
Esophageal foreign bodies in pediatric patients: a thirteen-year retrospective study.
Rybojad, Beata; Niedzielska, Grazyna; Niedzielski, Artur; Rudnicka-Drozak, Ewa; Rybojad, Pawel
2012-01-01
We discuss clinical symptoms and radiological findings of variable esophageal foreign bodies as well as therapeutic procedures in Caucasian pediatric patients. A retrospective study of 192 cases of suspected esophageal foreign bodies between 1998 and 2010 was conducted. Data were statistically analyzed by chi-square test. A foreign body was removed from a digestive tract of 163 children aged 6 months to 15 years (mean age 4.9). Most objects were located within cricopharyngeal sphincter. Dysphagia occurred in 43%, followed by vomiting (29%) and drooling (28%). The most common objects were coins. Plain chest X-rays demonstrated aberrations in 132 cases, and in doubtful situations an esophagram test was ordered. In the group of thirty-seven patients whose radiograms were normal, esophagoscopy revealed fifteen more objects, which were eventually successfully removed. No major complications occurred. Esophagram should be a second X-ray examination if an object is not detected in plain chest X-ray. We recommend a rigid esophagoscopy under general anesthesia in doubtful cases as a safe treatment for pediatric patients.
2013-01-01
Background In order to improve lung cancer survival in the UK, a greater proportion of resectable cancers must be diagnosed. It is likely that resectability rates would be increased by more timely diagnosis. Aside from screening, the only way of achieving this is to reduce the time to diagnosis in symptomatic cancers. Currently, lung cancers are mainly diagnosed by general practitioners (GPs) using the National Institute for Health and Clinical Excellence (NICE) guidelines for urgent referral for chest X-ray, which recommend urgent imaging or referral for patients who have one of a number of chest symptoms for more than 3 weeks. We are proposing to expand this recommendation to include one of a number of chest symptoms of any duration in higher-risk patients. Methods/Design We intend to conduct a trial of imaging in these higher-risk patients and compare it with NICE guidelines to see if imaging improves stage at diagnosis and resection rates. This trial would have to be large (and consequently resource-intensive) because most of these patients will not have lung cancer, making optimal design crucial. We are therefore conducting a pilot trial that will ascertain the feasibility of running a full trial and provide key information that will be required in order to design the full trial. Discussion This trial will assess the feasibility and inform the design of a large, UK-wide, clinical trial of a change to the NICE guidelines for urgent referral for chest X-ray for suspected lung cancer. It utilizes a combination of workshop, health economic, quality of life, qualitative, and quantitative methods in order to fully assess feasibility. Trial registration Clinicaltrials.gov NCT01344005 PMID:24279296
Measurement of sternal curvature angle on patients with pectus excavatum.
Lee, Cory; Zavala-Garcia, Abraham; Teekappanavar, Neha; Lee, Catherine; Idowu, Olajire; Kim, Sunghoon
2017-01-01
Pectus excavatum (PE) is a chest deformity characterized by marked sternal depression. The objective of this study was to quantify the sternal curvature observed in patients diagnosed with PE using the sternal curvature angle (SCA). A retrospective review of lateral chest X-rays of patients with PE from 2006 to 2013 was performed. The SCA was measured in a manner similar to the method of Cobb's angle is used to measure spinal curvature. SCA and Haller index were calculated from the chest X-rays for all patients. Lateral chest X-rays of 202 PE and 196 normal control patients were analyzed. The mean SCA ± SD of PE patients was 40.56° ± 12.88° compared to 22.02° ± 7.65° for normal patients. The difference was statistically significant with a p value of <0.0001. No significant concordance between SCA and Haller index measurements in the PE group was found (Kendall τ = -0.00015, p value = 0.9975). The difference in sternal curvature as measured by the sternal curvature angle between the pectus excavatum and normal patients was statistically significant. Our data suggest that sternal depression evident in PE patients is not a simple linear depression of the sternum but due to curvature in the sternal body.
Ultrasound estimation of volume of postoperative pleural effusion in cardiac surgery patients.
Usta, Engin; Mustafi, Migdat; Ziemer, Gerhard
2010-02-01
The aim of this study was to establish a practical simplified formula to facilitate the management of a frequently occurring postoperative complication, pleural effusion. Chest ultrasonography with better sensitivity and reliability in the diagnosis of pleural effusions than chest X-ray can be repeated serially at the bedside without any radiation risk. One hundred and fifty patients after cardiac surgery with basal pleural opacity on chest X-ray have been included in our prospective observational study during a two-year period. Effusion was confirmed on postoperative day (POD) 5.9+/-3.2 per chest ultrasound sonography. Inclusion criteria for subsequent thoracentesis based on clinical grounds alone and were not protocol-driven. Major inclusion criteria were: dyspnea and peripheral oxygen saturation (SpO(2)) levels < or = 92% and the maximal distance between mid-height of the diaphragm and visceral pleura (D > or = 30 mm). One hundred and thirty-five patients (90%) were drained with a 14-G needle if according to the simplified formula: V (ml)=[16 x D (mm)] the volume of the pleural effusion was around 500 ml. The success rate of obtaining fluid was 100% without any complications. There is a high accuracy between the estimated and drained pleural effusion. Simple quantification of pleural effusion enables time and cost-effective decision-making for thoracentesis in postoperative patients.
Bubble CPAP for respiratory distress syndrome in preterm infants.
Koti, Jagdish; Murki, Srinivas; Gaddam, Pramod; Reddy, Anupama; Reddy, M Dasaradha Rami
2010-02-01
To ascertain the immediate outcome of preterm infants with respiratory distress syndrome (RDS) on Bubble CPAP and identify risk factors associated with its failure. Prospective analytical study. Inborn preterm infants (gestation 28 to 34 weeks) admitted to the NICU with respiratory distress and chest X ray suggestive of RDS. Bubble CPAP with bi-nasal prongs. CPAP failures infants requiring ventilation in the first one week. 56 neonates were enrolled in the study. 14 (25%) babies failed CPAP. The predictors of failure were; no or only partial exposure to antenatal steroids, white-out on the chest X-ray, patent ductus arteriosus, sepsis/pneumonia and Downes score > 7 or FiO2 > or = 50% after 15-20 minutes of CPAP. Other maternal and neonatal variables did not influence the need for ventilation. Rates of mortality and duration of oxygen requirement was significantly higher in babies who failed CPAP. Only two infants developed pneumothorax. No baby had chronic lung disease. Infants with no or partial exposure to antenatal steroids, white-out chest X-ray, patent ductus arteriosus, sepsis/pneumonia and those with higher FiO2 requirement after initial stabilization on CPAP are at high risk of CPAP failure (needing mechanical ventilation). Bubble CPAP is safe for preterm infants with RDS.
Spontaneous pneumomediastinum and subcutaneous emphysema in systemic lupus erythematosus
Ahmed, AlaEldin H; Awouda, Elrasheid A
2010-01-01
We report a case of a 29-year-old woman who is known to have systemic lupus erythematosus and idiopathic interstitial pneumonia; she presented with a 1-day history of substernal chest pain and increasing shortness of breath. On examination, she was found breathless, but was not distressed or afebrile or normotensive. Auscultation of the heart revealed a positive Hamman's sign. There was chest-wall crepitus, and auscultation of the lung showed bilateral crepitations. Full blood count and biochemical profile were unremarkable. Chest x-ray showed signs of idiopathic interstitial pneumonia in addition to pneumomediastinum (linear band of air within mediastinal planes and continuous diaphragm sign) and chest-wall subcutaneous emphysema. She was treated with high-concentration oxygen. A repeat chest x-ray 5 days later showed complete resolution of the pneumomediastinum and subcutaneous emphysema, but signs of idiopathic interstitial pneumonia continued to persist. PMID:22767622
A Case of Pneumonia Caused by Pneumocystis jirovecii Resistant to Trimethoprim-Sulfamethoxazole.
Lee, Sang Min; Cho, Yong Kyun; Sung, Yon Mi; Chung, Dong Hae; Jeong, Sung Hwan; Park, Jeong-Woong; Lee, Sang Pyo
2015-06-01
A 50-year-old male visited the outpatient clinic and complained of fever, poor oral intake, and weight loss. A chest X-ray demonstrated streaky and fibrotic lesions in both lungs, and chest CT revealed multifocal peribronchial patchy ground-glass opacities with septated cystic lesions in both lungs. Cell counts in the bronchoalveolar lavage fluid revealed lymphocyte-dominant leukocytosis, and further analysis of lymphocyte subsets showed a predominance of cytotoxic T cells and few T helper cells. Video-assisted wedge resection of the left upper lobe was performed, and the histologic examination was indicative of a Pneumocystis jirovecii infection. Trimethoprim-sulfamethoxazole (TMP-SMX) was orally administered for 3 weeks; however, the patient complained of cough, and the pneumonia was aggravated in the follow-up chest X-ray and chest CT. Molecular studies demonstrated mutations at codons 55 and 57 of the dihydropteroate synthase (DHPS) gene, which is associated with the resistance to TMP-SMX. Clindamycin-primaquine was subsequently administered for 3 weeks replacing the TMP-SMX. A follow-up chest X-ray showed that the pneumonia was resolving, and the cough was also alleviated. A positive result of HIV immunoassay and elevated titer of HCV RNA indicated HIV infection as an underlying condition. This case highlights the importance of careful monitoring of patients with P. jirovecii pneumonia (PCP) during the course of treatment, and the molecular study of DHPS mutations. Additionally, altering the anti-PCP drug utilized as treatment must be considered when infection with drug-resistant P. jirovecii is suspected. To the best of our knowledge, this is the first case of TMP-SMX-resistant PCP described in Korea.
Andrieu, Nadine; Easton, Douglas F; Chang-Claude, Jenny; Rookus, Matti A; Brohet, Richard; Cardis, Elisabeth; Antoniou, Antonis C; Wagner, Teresa; Simard, Jacques; Evans, Gareth; Peock, Susan; Fricker, Jean-Pierre; Nogues, Catherine; Van't Veer, Laura; Van Leeuwen, Flora E; Goldgar, David E
2006-07-20
Women who carry germline mutations in the BRCA1 and BRCA2 genes are at greatly increased risk of breast cancer (BC). Numerous studies have shown that moderate to high doses of ionizing radiation are a risk factor for BC. Because of the role of the BRCA proteins in DNA repair, we hypothesized that BRCA carriers might be more sensitive to ionizing radiation than women in the general population. A retrospective cohort study of 1,601 female BRCA1/2 carriers was performed. Risk of breast cancer from exposure to chest x-rays, as assessed by questionnaire data, was analyzed using a weighted Cox proportional hazards model. In this cohort, any reported exposure to chest x-rays was associated with an increased risk of BC (hazard ratio [HR] = 1.54; P = .007). This risk was increased in carrier women aged 40 years and younger (HR = 1.97; P < .001) and in women born after 1949 (HR = 2.56; P < .001), particularly those exposed only before the age of 20 years (HR = 4.64; P < .001). In our series of BRCA carriers, we detected a relatively large effect on BC risk with a level of radiation exposure that is at least an order of magnitude lower than in previously studied medical radiation-exposed cohorts. Although part of this increase may be attributable to recall bias, the observed patterns of risk in terms of age at exposure and attained age are consistent with those found in previous studies. If confirmed, the results have important implications for the use of x-ray imaging in young BRCA1/2 carriers.
Lindroth, M; Mortensson, W
1986-09-01
Chest X-ray, pulmonary mechanics, clinical lung disease and growth were studied in 48 low birthweight infants surviving after ventilator treatment in the neonatal period. Bronchopulmonary dysplasia (BPD) was present in 14 infants shortly after weaning off ventilator. At 4 to 6 years of age most patients had normal chest radiographs but 13 still showed signs of pulmonary fibrosis and hyperinflation. Most patients had low dynamic compliance and high pulmonary resistance shortly after ventilator treatment. All but 8, however, had normal findings at 1 to 1 1/2 years of age. Pneumonias and bronchitis were common during the first two years but thereafter declined in frequency. Weight and length development were retarded for BPD patients during the first two years and for non-BPD patients for the first year. Both groups had a complete catch-up.
... also be done if you have signs of tuberculosis , lung cancer , or other chest or lung diseases . ... the blood vessels Pneumonia Scarring of lung tissue Tuberculosis In the heart: Problems with the size or ...
1990-12-01
ears ( tinnitus ) and/or a reduced auditory acuity resulted from the dosing. These side effects have been shown to 29 occur in some subjects as a result of...examinations. 5. Complete blood count (CBC). 6. Blood biochemistry screen (Chem 18 including liver function tests). 7. Blood cholesterol and lipids . 8. Chest X...blood lipids and cholesterol, chest X-ray, urinalysis, visual acuity test, vestibular evaluation and liver function studies. Subjects will then take
Chest radiographic manifestations of scrub typhus.
Abhilash, Kpp; Mannam, P R; Rajendran, K; John, R A; Ramasami, P
2016-01-01
Respiratory system involvement in scrub typhus is seen in 20-72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. The study cohort contained 398 patients. Common presenting complaints included fever (100%), generalized myalgia (83%), headache (65%), dyspnea (54%), cough (24.3%), and altered sensorium (14%). Almost half of the patients (49.4%) had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%), acute respiratory distress syndrome (14%), airspace opacity (10.5%), reticulonodular opacities (10.3%), peribronchial thickening (5.8%), and pulmonary edema (2%). Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of <20,000 cells/cumm, and total serum bilirubin >2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89-33.16), invasive ventilation (OR: 18.07; 95% CI: 6.42-50.88), inotropes (OR: 8.76; 95% CI: 4.35-17.62), higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001), and higher mortality (OR: 4.63; 95% CI: 1.54-13.85). Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.
Older, R A; Synder, B; Krupski, T L; Glembocki, D J; Gillenwater, J Y
2001-05-01
In several of the initial patients undergoing brachytherapy at our institution radioactive implants were visible in the thorax on chest radiography. The clinical ramifications of this unanticipated finding were unclear. Thus, we investigated the incidence of brachytherapy seed migration to the chest and whether these seeds were associated with any clinical significance. We retrospectively reviewed the records of all patients who underwent ultrasound or computerized tomography guided brachytherapy of 103palladium seeds from March 1997 to March 1999. This list of patients on brachytherapy was then matched against the radiology computer system to determine those who had undergone chest X-ray after brachytherapy. When the radiology report was unclear regarding brachytherapy seeds, chest x-rays were reviewed by one of us (R. O.) to determine the presence and position of the seeds. Post-brachytherapy chest x-rays were available in 110 of the 183 patients. In 78 cases no brachytherapy seeds were identified. Radioactive implants were identified on chest radiography in 32 patients (29%), including 1 to 5 seeds in 20, 8, 1, 2 and 1, respectively. No patients complained of any change in pulmonary symptoms after brachytherapy. Radioactive implants migrated after brachytherapy for localized prostate cancer in 29% of the patients who underwent post-procedure radiography. There did not appear to be a pattern to the seed distribution. However, while the incidence was not negligible, no patient appeared to have any acute pulmonary symptoms. Therefore, while the migration of radioactive implants to the chest is a real phenomenon, it appears to have no adverse clinical consequences in the early post-procedure period.
The Role of Incentive Spirometry in Primary Spontaneous Pneumothorax.
Pribadi, Rabbinu R; Singh, Gurmeet; Rumende, Cleopas M
2016-01-01
Pneumothorax is the presence of air in the pleural space. Its management consists of noninvasive and invasive therapies and it is determined based on clinical manifestations, type and size of pneumothorax. We present a case of a patient with diagnosis of primary spontaneous pneumothorax treated with incentive spirometry (noninvasive therapy). A 20 year old man came to respirology clinic with chief complaint of shortness of breath. He was recently diagnosed with left pneumothorax based on previous chest X-ray in another health care facilities and was advised to undergo tube thoracostomy but he refused the procedure. On physical examination, vital signs were normal. Chest X-ray showed 33% of pneumothorax or 1.2 cm. He was asked to perform incentive spirometry therapy at home. During 12 days of therapy, shortness of breath slowly disappeared and on repeated chest X-ray, it showed minimal pneumothorax in the left upper hemithorax. Noninvasive treatment such as incentive spirometry can be considered in patient with minimal symptoms and no signs of life-threatening respiratory distress.
Chest x-ray generation and data augmentation for cardiovascular abnormality classification
NASA Astrophysics Data System (ADS)
Madani, Ali; Moradi, Mehdi; Karargyris, Alexandros; Syeda-Mahmood, Tanveer
2018-03-01
Medical imaging datasets are limited in size due to privacy issues and the high cost of obtaining annotations. Augmentation is a widely used practice in deep learning to enrich the data in data-limited scenarios and to avoid overfitting. However, standard augmentation methods that produce new examples of data by varying lighting, field of view, and spatial rigid transformations do not capture the biological variance of medical imaging data and could result in unrealistic images. Generative adversarial networks (GANs) provide an avenue to understand the underlying structure of image data which can then be utilized to generate new realistic samples. In this work, we investigate the use of GANs for producing chest X-ray images to augment a dataset. This dataset is then used to train a convolutional neural network to classify images for cardiovascular abnormalities. We compare our augmentation strategy with traditional data augmentation and show higher accuracy for normal vs abnormal classification in chest X-rays.
The health care provider will perform a physical exam. Tests include: Bone marrow biopsy Chest x-ray CT scan of the chest, abdomen, and pelvis Complete blood count (CBC) Examination of the spinal fluid Lymph node biopsy PET scan
Cardiac Computed Tomography (Multidetector CT, or MDCT)
... other tests, such as chest X-rays , electrocardiograms (ECG) , echocardiograms (echocardiography) , or stress tests , don’t give ... be attached to your chest to monitor your ECG. The ECG is also needed to help the ...
A software system for the simulation of chest lesions
NASA Astrophysics Data System (ADS)
Ryan, John T.; McEntee, Mark; Barrett, Saoirse; Evanoff, Michael; Manning, David; Brennan, Patrick
2007-03-01
We report on the development of a novel software tool for the simulation of chest lesions. This software tool was developed for use in our study to attain optimal ambient lighting conditions for chest radiology. This study involved 61 consultant radiologists from the American Board of Radiology. Because of its success, we intend to use the same tool for future studies. The software has two main functions: the simulation of lesions and retrieval of information for ROC (Receiver Operating Characteristic) and JAFROC (Jack-Knife Free Response ROC) analysis. The simulation layer operates by randomly selecting an image from a bank of reportedly normal chest x-rays. A random location is then generated for each lesion, which is checked against a reference lung-map. If the location is within the lung fields, as derived from the lung-map, a lesion is superimposed. Lesions are also randomly selected from a bank of manually created chest lesion images. A blending algorithm determines which are the best intensity levels for the lesion to sit naturally within the chest x-ray. The same software was used to run a study for all 61 radiologists. A sequence of images is displayed in random order. Half of these images had simulated lesions, ranging from subtle to obvious, and half of the images were normal. The operator then selects locations where he/she thinks lesions exist and grades the lesion accordingly. We have found that this software was very effective in this study and intend to use the same principles for future studies.
Nuisance levels of noise effects radiologists' performance
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Coffey, Amina; Ryan, John; O'Beirne, Aaron; Toomey, Rachel; Evanoff, Micheal; Manning, David; Brennan, Patrick C.
2010-02-01
This study aimed to measure the sound levels in Irish x-ray departments. The study then established whether these levels of noise have an impact on radiologists performance Noise levels were recorded 10 times within each of 14 environments in 4 hospitals, 11 of which were locations where radiologic images are judged. Thirty chest images were then presented to 26 senior radiologists, who were asked to detect up to three nodular lesions within 30 posteroanterior chest x-ray images in the absence and presence of noise at amplitude demonstrated in the clinical environment. The results demonstrated that noise amplitudes rarely exceeded that encountered with normal conversation with the maximum mean value for an image-viewing environment being 56.1 dB. This level of noise had no impact on the ability of radiologists to identify chest lesions with figure of merits of 0.68, 0.69, and 0.68 with noise and 0.65, 0.68, and 0.67 without noise for chest radiologists, non-chest radiologists, and all radiologists, respectively. the difference in their performance using the DBM MRMC method was significantly better with noise than in the absence of noise at the 90% confidence interval (p=0.077). Further studies are required to establish whether other aspects of diagnosis are impaired such as recall and attention and the effects of more unexpected noise on performance.
NASA Astrophysics Data System (ADS)
Mohd. Rijal, Omar; Mohd. Noor, Norliza; Teng, Shee Lee
A statistical method of comparing two digital chest radiographs for Pulmonary Tuberculosis (PTB) patients has been proposed. After applying appropriate image registration procedures, a selected subset of each image is converted to an image histogram (or box plot). Comparing two chest X-ray images is equivalent to the direct comparison of the two corresponding histograms. From each histogram, eleven percentiles (of image intensity) are calculated. The number of percentiles that shift to the left (NLSP) when second image is compared to the first has been shown to be an indicator of patients` progress. In this study, the values of NLSP is to be compared with the actual diagnosis (Y) of several medical practitioners. A logistic regression model is used to study the relationship between NLSP and Y. This study showed that NLSP may be used as an alternative or second opinion for Y. The proposed regression model also show that important explanatory variables such as outcomes of sputum test (Z) and degree of image registration (W) may be omitted when estimating Y-values.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... DEPARTMENT OF STATE [Public Notice 6995] 30-Day Notice of Proposed Information Collection: Forms DS-2053, DS-2054; Medical Examination for Immigrant or Refugee Applicant; DS- 3030, Chest X-Ray and..., Medical Examination for Immigrant or Refugee Applicant (2007 Technical Instructions); and DS-3030, Chest X...
Occult pneumomediastinum in blunt chest trauma: clinical significance.
Rezende-Neto, J B; Hoffmann, J; Al Mahroos, M; Tien, H; Hsee, L C; Spencer Netto, F; Speers, V; Rizoli, S B
2010-01-01
Thoracic injuries are potentially responsible for 25% of all trauma deaths. Chest X-ray is commonly used to screen patients with chest injury. However, the use of computed tomography (CT) scan for primary screening is increasing, particularly for blunt trauma. CT scans are more sensitive than chest X-ray in detecting intra-thoracic abnormalities such as pneumothoraces and pneumomediastinums. Pneumomediastinum detected by chest X-ray or "overt pneumomediastinum", raises the concern of possible aerodigestive tract injuries. In contrast, there is scarce information on the clinical significance of pneumomediastinum diagnosed by CT scan only or "occult pneumomediastinum". Therefore we investigated the clinical consequences of occult pneumomediastinum in our blunt trauma population. A 2-year retrospective chart review of all blunt chest trauma patients with initial chest CT scan admitted to a level I trauma centre. Data extracted from the medical records include; demographics, occult, overt, or no pneumomediastinum, the presence of intra-thoracic aerodigestive tract injuries (trachea, bronchus, and/or esophagus), mechanism and severity of injury, endotracheal intubation, chest thoracostomy, operations and radiological reports by an attending radiologist. All patients with intra-thoracic aerodigestive tract injuries from 1994 to 2004 were also investigated. Of 897 patients who met the inclusion criteria 839 (93.5%) had no pneumomediastinum. Five patients (0.6%) had overt pneumomediastinum and 53 patients (5.9%) had occult pneumomediastinum. Patients with occult pneumomediastinum had significantly higher ISS and AIS chest (p<0.0001) than patients with no pneumomediastinum. A chest thoracostomy tube was more common (p<0.0001) in patients with occult pneumomediastinum (47.2%) than patients with no pneumomediastinum (10.4%), as well as occult pneumothorax. None of the patients with occult pneumomediastinum had aerodigestive tract injuries (95%CI 0-0.06). Follow up CT scan of patients with occult pneumomediastinum showed complete resolution in all cases, in average 3 h after the initial exam. Occult pneumomediastinum occurred in approximately 6% of all trauma patients with blunt chest injuries in our institution. Patients who had occult pneumomediastinum were more severely injured than those who without. However, none of the patients with occult pneumomediastinum had aerodigestive tract injuries and follow up chest CT scans demonstrated their complete and spontaneous resolution.
The health care provider will perform a physical exam, and ask about your medical history and symptoms. Tests that may be done include: Bronchoscopy with culture Complete blood count (CBC) Chest x-ray Chest CT scan Lung biopsy Modified AFB smear of sputum ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klech, H.; Kohn, H.; Kummer, F.
1982-12-01
The value of different factors are examined to assess activity in 60 patients with biopsy-proven sarcoidosis. In patients with active sarcoidosis (n . 35), /sup 67/Ga scans proved to be the most sensitive method (94 percent sensitivity), followed by serum angiotensin I converting enzyme (S-ACE) levels, chest x-ray films, and lymphocyte assays. In patients with peripheral pulmonary lesions, chest x-ray films failed in 32 percent of cases to document activity (68 percent sensitivity) whereas /sup 67/Ga scans and S-ACE levels remained to give reliable results. Despite poor specificity, negative /sup 67/Ga scans together with normal ACE levels have a highmore » predictive value for exclusion of active sarcoidosis. In patients with peripheral pulmonary lesions, chest roentgenography is of doubtful value for staging lung involvement and assessment of activity including monitoring and control of therapy.« less
Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.
Tanaka, Rie
2016-07-01
Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.
National Lung Screening Trial (NLST)
The National Lung Screening Trial (NLST), a research study sponsored by the National Cancer Institute that used low-dose helical CT scans or chest X-ray to screen men and women at risk for lung cancer.
Bas Mor, H; Altinsoy, N; Söyler, I
2018-05-08
The aim of this study was to evaluate the radiation doses to patient during chest (posterior anterior/and lateral) examinations. The study was performed in three public hospitals of İstanbul province with a total of 300 adult patients. Entrance surface dose (ESD) measurements were conducted on computed radiography, digital radiography and screen film system. ESD was estimated by using International Atomic Energy Agency (IAEA) model and Davies model which are the common indirect models. Results were compared with diagnostic reference levels from the European Commission, IAEA and National Radiological Protection Board. Although the results are compatible with the international diagnostic reference levels, they present variations between the hospitals. Dose variations for the same type of X-ray examination support the idea that further optimization is possible.
... esophagus into the space around the lungs. Collapsed lung. X-rays taken after you drink a non-harmful dye can help pinpoint the location of the perforation. You may also have chest CT scan look for an abscess in the chest or esophageal cancer.
Milkovic, Durdica; Garaj-Vrhovac, Vera; Ranogajec-Komor, Mária; Miljanic, Saveta; Gajski, Goran; Knezevic, Zeljka; Beck, Natko
2009-01-01
The aim of this work is to assess DNA damage in peripheral blood lymphocytes of children prior to and following airway X-ray examinations of the chest using the alkaline comet assay and to compare data with the measured absorbed dose. Twenty children with pulmonary diseases, between the ages of 5 and 14 years, are assessed. Absorbed dose measurements are conducted for posterior-anterior projection on the forehead, thyroid gland, gonads, chest, and back. Doses are measured using thermoluminescent and radiophotoluminescent dosimetry systems. Differences between tail lengths, tail intensity, and tail moments as well as for the long-tailed nuclei before and after exposures are statistically significant and are dependent on the individual. The results demonstrate the usefulness of the comet assay as a measure of X-ray damage to lymphocytes in a clinical setting. Doses measured with both dosimeters show satisfactory agreement (0.01 mSv) and are suitable for dosimetric measurements in X-ray diagnostics.
Heart bypass surgery - series (image)
... or more coronary arteries are seriously blocked and blood supply to the heart muscle is insufficient. Several tests are done to identify the cause of the chest pain (angina), such as blood tests and x-ray studies (angiograms).
Latest NIH Research | NIH MedlinePlus the Magazine
... this page please turn Javascript on. Feature: Quit Smoking Latest NIH Research Past Issues / Winter 2011 Table ... with chest X-rays. Clinical Trials Related to Smoking Clinical trials are scientific studies that try to ...
Comparison study of noise reduction algorithms in dual energy chest digital tomosynthesis
NASA Astrophysics Data System (ADS)
Lee, D.; Kim, Y.-S.; Choi, S.; Lee, H.; Choi, S.; Kim, H.-J.
2018-04-01
Dual energy chest digital tomosynthesis (CDT) is a recently developed medical technique that takes advantage of both tomosynthesis and dual energy X-ray images. However, quantum noise, which occurs in dual energy X-ray images, strongly interferes with diagnosis in various clinical situations. Therefore, noise reduction is necessary in dual energy CDT. In this study, noise-compensating algorithms, including a simple smoothing of high-energy images (SSH) and anti-correlated noise reduction (ACNR), were evaluated in a CDT system. We used a newly developed prototype CDT system and anthropomorphic chest phantom for experimental studies. The resulting images demonstrated that dual energy CDT can selectively image anatomical structures, such as bone and soft tissue. Among the resulting images, those acquired with ACNR showed the best image quality. Both coefficient of variation and contrast to noise ratio (CNR) were the highest in ACNR among the three different dual energy techniques, and the CNR of bone was significantly improved compared to the reconstructed images acquired at a single energy. This study demonstrated the clinical value of dual energy CDT and quantitatively showed that ACNR is the most suitable among the three developed dual energy techniques, including standard log subtraction, SSH, and ACNR.
X-ray examinations during pregnancy: National Natality Surveys, 1963 and 1980.
Kaczmarek, R G; Moore, R M; Keppel, K G; Placek, P J
1989-01-01
Based on 1963 and 1980 National Natality Surveys, the rate of medical x-ray examinations during pregnancy per 100 mothers fell 34.2 percent. A decrease in chest x-ray examinations accounted for almost all of the decline in total x-ray examinations. The reductions were greater for older mothers and those who were not White. While the number of births fell from 4,071,000 in 1963 to 3,612,000 in 1980, the number of pelvimetry examinations actually increased by 45,000. PMID:2909188
Organ dose measurement using Optically Stimulated Luminescence Detector (OSLD) during CT examination
NASA Astrophysics Data System (ADS)
Yusuf, Muhammad; Alothmany, Nazeeh; Abdulrahman Kinsara, Abdulraheem
2017-10-01
This study provides detailed information regarding the imaging doses to patient radiosensitive organs from a kilovoltage computed tomography (CT) scan procedure using OSLD. The study reports discrepancies between the measured dose and the calculated dose from the ImPACT scan, as well as a comparison with the dose from a chest X-ray radiography procedure. OSLDs were inserted in several organs, including the brain, eyes, thyroid, lung, heart, spinal cord, breast, spleen, stomach, liver and ovaries, of the RANDO phantom. Standard clinical scanning protocols were used for each individual site, including the brain, thyroid, lung, breast, stomach, liver and ovaries. The measured absorbed doses were then compared with the simulated dose obtained from the ImPACT scan. Additionally, the equivalent doses for each organ were calculated and compared with the dose from a chest X-ray radiography procedure. Absorbed organ doses measured by OSLD in the RANDO phantom of up to 17 mGy depend on the organ scanned and the scanning protocols used. A maximum 9.82% difference was observed between the target organ dose measured by OSLD and the results from the ImPACT scan. The maximum equivalent organ dose measured during this experiment was equal to 99.899 times the equivalent dose from a chest X-ray radiography procedure. The discrepancies between the measured dose with the OSLD and the calculated dose from the ImPACT scan were within 10%. This report recommends the use of OSLD for measuring the absorbed organ dose during CT examination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hopf, K.
1961-09-01
A comparison of the number of registered tuberculous patients in the German Democratic Republic and Hungary showed that in 1956 Hungary recorded a rate of 1.33% patients with active tuberculosis, whereas Germany showed 1.22%. The difference in these percentages indicates that different standards were applied in classifying patients as inactive, chronic-active, or infectuous tuberculotics. This study showed that some patients were carried Mn the records as tuberculotics who have long been cured and should have been classified ss inactive. The practice of annual chest x-ray examination for the entire population for the purpose of detecting new cases of tuberculosis ismore » discussed (and accepted practice in the German Democratic Republic). The possible hazards to humans from such radiation exposure are considered. It is concluded that chest x rays carried out by properly trained personnel do not constitute and particular hazard to the patient provided proper screens are used and fluoroscopic exposure is not longer thand 30 sec. Testimony of expert roentgenologists is cited which maintains that the doses received in a series of routine chest x rays are no more than the average natural radiation dose received by and individual. This method, therefore, should not be discarded as an effective method for the detection of new, active cases of tuberculosis. (BBB)« less
Rady, Hanaa Ibrahim; Zekri, Hanan
2015-01-01
To assess children with myocarditis, the frequency of various presenting symptoms, and the accuracy of different investigations in the diagnosis. This was an observational study of 63 patients admitted to PICU with non-cardiac diagnosis. Cardiac enzymes, chest-X ray, echocardiography, and electrocardiogram were performed to diagnose myocarditis among those patients. There were 16 cases of definite myocarditis. The age distribution was non-normal, with median of 5.5 months (3.25-21). Of the 16 patients who were diagnosed with myocarditis, 62.5% were originally diagnosed as having respiratory problems, and there were more females than males. Among the present cases, the accuracy of cardiac enzymes (cardiac troponin T [cTn] and creatine phosphokinase MB [CKMB]) in the diagnosis of myocarditis was only 63.5%, while the accuracy of low fractional shortening and of chest-X ray cardiomegaly was 85.7 and 80.9%; respectively. Cardiac troponin folds 2.02 had positive predictive value of 100%, negative predictive value of 88.7%, specificity of 100%, sensitivity of 62.5%, and accuracy of 90.5%. Children with myocarditis present with symptoms that can be mistaken for other types of illnesses. When clinical suspicion of myocarditis exists, chest-X ray and echocardiography are sufficient as screening tests. Cardiac troponins confirm the diagnosis in screened cases, with specificity of 100%. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Cavaliere, F; Biasucci, D; Costa, R; Soave, M; Addabbo, G; Proietti, R
2011-07-01
Reexpansion of a pulmonary atelectasis is often difficult, even after removing possible causes of bronchial obstruction. Chest ultrasounds, inexpensive and readily available at the patient bedside, may offer valuable support to guide recruitment maneuvers. We report the case of a 57-year-old woman that developed a complete collapse of the left lung seven days after undergoing an intestinal resection for perforation. A mucous plug occluding the main bronchus was removed with bronchoscopy, but persistent hypoxemia required mechanical ventilation; 24 hours later, an attempt to wean the patient from the ventilator failed. Chest X-rays revealed the persistence of a partial collapse of the left inferior lobe associated with a pleural effusion. A chest ultrasound confirmed the presence of a lung consolidation and of a modest pleural effusion. Manual reexpansion was then attempted, and ventilatory pressures as well as the duration of forced inspirations were based on real-time ultrasound images. Complete reexpansion was achieved within a few minutes and confirmed by chest X-ray. The patient was weaned from mechanical ventilation on the same day and discharged from ICU three days later.
Anzai, Fumio; Yamamoto, Akito; Tannai, Noriyuki; Abe, Hideki; Tsuchiya, Kayoko; Kusajima, Kenji; Shimoide, Hisao; Nunomura, Maki
2009-07-01
A 62-year-old man had felt cold-like symptoms for 2 months. He visited a clinic for a health check in late July 1998 and chest X-ray film showed an infiltrative shadow in the left middle and lower lung fields. Next day he had a fever of 38.3 degrees C and felt breathless. Six days thereafter he had a cough, thick head and felt fatigue. Chest X-ray films showed other infiltrative shadows in the bilateral upper lung fields. He worked in a race track and was exposed to pigeons and seabirds at that time. Culture of sputum grew Cryptococcus neoformans. He was admitted and was treated with intravenous antifungal drugs. Cerebrospinal fluid examination revealed positive Indian ink stain for C. neoformans. The CD4 + T-lymphocyte count and CD8 + T-lymphocyte count were 143.4 cells/mm3 and 1288.8 cells/mm3 respectively, but without HIV infection. Cryptococcal pneumonia and meningitis with Idiopathic CD4 + T-lymphocytopenia was diagnosed. After induction therapy, the symptoms improved but abnormal shadows remained on chest X-ray films. Maintenance therapy has been continued at doses of 200 mg/day of fluconazole for 10 years. He has had no symptoms, but the abnormal X-ray shadow has persisted and the CD4 count has remained low during the same period.
Ebrahimzadeh, Azadeh; Mohammadifard, Mahyar; Naseh, Godratallah; Mirgholami, Alireza
2015-01-01
Pneumonia is a common illness in all parts of the world and is considered as a major cause of death among all age groups. Nevertheless, only about 5% of patients referring to their primary care physicians with acute respiratory symptoms will develop pneumonia. This study was performed to derive practical criteria for performing chest radiographs for the evaluation of community-acquired pneumonia (CAP). A total of 420 patients with acute respiratory symptoms and positive findings on chest radiograph were evaluated from December 2008 to December 2009. The subjects were referred to outpatient clinics or emergency departments of Birjand's medical university hospitals, Iran, and were enrolled as positive cases. A checklist was completed for each patient including their demographic information, clinical signs and symptoms (cough, sputum production, dyspnea, chest pain, fever, tachycardia, and tachypnea), abnormal findings in pulmonary auscultation and laboratory findings (erythrocyte sedimentation rate, C-reactive protein levels, and white blood cell count). An equal number of age-matched individuals with acute respiratory symptoms, but insignificant findings on chest radiography, were included as the control group. Finally, the diagnostic values of different findings were compared. The data showed that vital signs and physical examination findings are useful screening parameters for predicting chest radiograph findings in outpatient settings. Therefore, by implementing a prediction rule, we would be able to determine which patients would benefit from a chest X-Ray (sensitivity, 94% and specificity, 57%). This study's findings suggest that requesting chest radiographs might not be necessary in patients with acute respiratory symptoms unless the vital signs and/or physical examination findings are abnormal. Considering the 94% sensitivity of this rule for predicting CAP, a chest radiograph is required for patients with unreliable follow-ups or moderate to high likelihood of morbidity if CAP is not initially detected.
Evaluation of effective dose with chest digital tomosynthesis system using Monte Carlo simulation
NASA Astrophysics Data System (ADS)
Kim, Dohyeon; Jo, Byungdu; Lee, Youngjin; Park, Su-Jin; Lee, Dong-Hoon; Kim, Hee-Joung
2015-03-01
Chest digital tomosynthesis (CDT) system has recently been introduced and studied. This system offers the potential to be a substantial improvement over conventional chest radiography for the lung nodule detection and reduces the radiation dose with limited angles. PC-based Monte Carlo program (PCXMC) simulation toolkit (STUK, Helsinki, Finland) is widely used to evaluate radiation dose in CDT system. However, this toolkit has two significant limits. Although PCXMC is not possible to describe a model for every individual patient and does not describe the accurate X-ray beam spectrum, Geant4 Application for Tomographic Emission (GATE) simulation describes the various size of phantom for individual patient and proper X-ray spectrum. However, few studies have been conducted to evaluate effective dose in CDT system with the Monte Carlo simulation toolkit using GATE. The purpose of this study was to evaluate effective dose in virtual infant chest phantom of posterior-anterior (PA) view in CDT system using GATE simulation. We obtained the effective dose at different tube angles by applying dose actor function in GATE simulation which was commonly used to obtain the medical radiation dosimetry. The results indicated that GATE simulation was useful to estimate distribution of absorbed dose. Consequently, we obtained the acceptable distribution of effective dose at each projection. These results indicated that GATE simulation can be alternative method of calculating effective dose in CDT applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdallah, I; Aly, A; Al Naemi, H
Purpose: The aim of this study was to evaluate radiation doses to pediatric patients undergoing standard radiographic examinations using Direct Digital Radiography (DDR) in Paediatric emergency center of Hamad General Hospital (HGH) in state of Qatar and compared with regional and international Dose Reference Levels (DRLs). Methods: Entrance Skin Dose (ESD) was measured for 2739 patients for two common X-ray examinations namely: Chest AP/PA, Abdomen. Exposure factors such as kV, mAs and Focal to Skin Distance (FSD) were recorded for each patient. Tube Output was measured for a range of selected kV values. ESD for each individual patient was calculatedmore » using the tube output and the technical exposure factors for each examination. The ESD values were compared with the some international Dose Reference Levels (DRL) for all types of examinations. Results: The most performed procedure during the time of this study was chest PA/PA (85%). The mean ESD values obtained from AP chest, PA chest and AP abdomen ranged 91–120, 80–84 and 209 – 659 µGy per radiograph for different age’s groups respectively. Two protocols have been used for chest AP and PA using different radiological parameters, and the different of ESD values for chest PA and were 41% for 1 years old child, 57% for 5 years old for chest AP. Conclusion: The mean ESD were compared with those found in literature and were found to be comparable. The radiation dose can be reduced more for Chest AP and PA examination by optimization of each investigation and hence more studies are required for this task. The results presented will serve as a baseline data needed for deriving local reference doses for pediatric X-ray examinations in this local department and hence it can be applied in the whole Qatar.« less
NASA Astrophysics Data System (ADS)
Hsu, Fang-Yuh; Hsu, Shih-Ming; Chao, Jiunn-Hsing
2017-11-01
The subject of this study is the on-site visits and inspections of facilities commissioned by the Atomic Energy Council (AEC) in Taiwan. This research was conducted to evaluate the possible dose and dose rate of cabinet-type X-ray equipment with nominal voltages of 30-150 kV and open-beam (portable or handheld) equipment, taking both normal operation and possibly abnormal operation conditions into account. Doses and dose rates were measured using a plastic scintillation survey meter and an electronic personal dosimeter. In total, 401 X-ray machines were inspected, including 139 units with nominal voltages of 30-50 kV X-ray equipment, 140 units with nominal voltages of 50-150 kV, and 122 open-beam (portable or handheld) X-ray equipment. The investigated doses for radiation workers and non-radiation workers operating cabinet-type X-ray equipment under normal safety conditions were all at the background dose level. Several investigated dose rates at the position of 10 cm away from the surface of open-beam (portable or handheld) X-ray equipment were very high, such X-ray machines are used by aeronautical police for the detection of suspected explosives, radiation workers are far away (at least 10 m away) from the X-ray machine during its operation. The doses per operation in X-ray equipment with a 30-50 kV nominal voltage were less than 1 mSv in all cases of abnormal use. Some doses were higher than 1 mSv per operation for X-ray equipment of 50-150 kV nominal voltage X-ray. The maximum dose rates at the beam exit have a very wide range, mostly less than 100 μSv/s and the largest value is about 3.92 mSv/s for open-beam (portable or handheld) X-ray devices. The risk induced by operating X-ray devices with nominal voltages of 30-50 kV is extremely low. The 11.5 mSv dose due to one operation at nominal voltage of 50-150 kV X-ray device is equivalent to the exposure of taking 575 chest X-rays. In the abnormal use of open-beam (portable or handheld) X-ray equipment, the effective dose of 3.92 mSv/s is equivalent to taking 196 chest radiographs within 1 s. This work assessed the annual doses (equivalent and effective doses) and risks of X-ray operator staff as reasonably as possible. The results of this research are helpful to the AEC (competent authority of ionization radiation) to improve the management and perform the safe control of X-ray equipment.
Chest tomosynthesis: technical principles and clinical update.
Dobbins, James T; McAdams, H Page
2009-11-01
Digital tomosynthesis is a radiographic technique that can produce an arbitrary number of section images of a patient from a single pass of the X-ray tube. It utilizes a conventional X-ray tube, a flat-panel detector, a computer-controlled tube mover, and special reconstruction algorithms to produce section images. While it does not have the depth resolution of computed tomography (CT), tomosynthesis provides some of the tomographic benefits of CT but at lower cost and radiation dose than CT. Compared to conventional chest radiography, chest tomosynthesis results in improved visibility of normal structures such as vessels, airway and spine. By reducing visual clutter from overlying normal anatomy, it also enhances detection of small lung nodules. This review article outlines the components of a tomosynthesis system, discusses results regarding improved lung nodule detection from the recent literature, and presents examples of nodule detection from a clinical trial in human subjects. Possible implementation strategies for use in clinical chest imaging are discussed.
Non-Hodgkin Lymphoma (For Parents)
... chest X-ray a computerized tomography (CT or CAT) scan , which rotates around the patient and creates an ... ray (Video) Getting an MRI (Video) Getting a CAT Scan (Video) Chemotherapy Hodgkin Lymphoma Stem Cell Transplants Can ...
[A case of flomoxef-induced pneumonitis].
Wako, Y; Hamauzu, T; Tamura, M; Yokote, M; Yokote, M; Shoji, S; Takikawa, H; Miyake, K; Yamanaka, M; Goto, H
1992-04-01
We report a case of flomoxef-induced pneumonitis. A 22-year-old man was treated with flomoxef following liver biopsy. A few days later he developed a high fever and severe dyspnea, and his chest X-ray film revealed diffuse reticulo-nodular shadows in both lung fields. We suspected interstitial pneumonitis due to flomoxef, and pulse therapy with methylprednisolone was started. He showed rapid recovery of symptoms and marked regression of pulmonary infiltration in his chest X-ray. Lymphocyte stimulation test was positive to flomoxef, which was compatible with the diagnosis of drug-induced pneumonitis. To our knowledge, there has been no previous case of pulmonary hypersensitivity to flomoxef reported in Japan.
Evaluation of a Noise Reduction Procedure for Chest Radiography
Fukui, Ryohei; Ishii, Rie; Kodani, Kazuhiko; Kanasaki, Yoshiko; Suyama, Hisashi; Watanabe, Masanari; Nakamoto, Masaki; Fukuoka, Yasushi
2013-01-01
Background The aim of this study was to evaluate the usefulness of noise reduction procedure (NRP), a function in the new image processing for chest radiography. Methods A CXDI-50G Portable Digital Radiography System (Canon) was used for X-ray detection. Image noise was analyzed with a noise power spectrum (NPS) and a burger phantom was used for evaluation of density resolution. The usefulness of NRP was evaluated by chest phantom images and clinical chest radiography. We employed the Bureau of Radiological Health Method for scoring chest images while carrying out our observations. Results NPS through the use of NRP was improved compared with conventional image processing (CIP). The results in image quality showed high-density resolution through the use of NRP, so that chest radiography examination can be performed with a low dose of radiation. Scores were significantly higher than for CIP. Conclusion In this study, use of NRP led to a high evaluation in these so we are able to confirm the usefulness of NRP for clinical chest radiography. PMID:24574577
Insulation defects in Riata implantable cardioverter-defibrillator leads.
Sato, Akinori; Chinushi, Masaomi; Iijima, Kenichi; Izumi, Daisuke; Furushima, Hiroshi
2012-01-01
The structures composing implantable cardioverter-defibrillator (ICD) leads have become more complicated and thinner with technological advances. Silicon insulation defects with and without clinically manifested electrical abnormalities have been reported in Riata leads (St. Jude Medical). The aim of this study was to assess the incidence and clinical implications of insulation defects in Riata leads implanted at our hospital. The subjects included 10 consecutive patients who received 8-French Riata ICD leads with dual-coil conductors (model 1580 or 1581) between 2006 and 2010 at our hospital. Operative records, chest X-rays and interrogation data were reviewed. In all cases, Atlas+ (St. Jude Medical) was used as an ICD generator and the Riata leads were implanted transvenously and fixed to the right ventricular apex. During a mean follow-up period of 52±9 (36-70) months, chest X-rays revealed insulation defects in Riata leads and conductor wires projecting from the bodies of the Riata leads in two of 10 (20%) patients. One of the patients received inappropriate ICD therapies due to T-wave oversensing based on attenuation of R waves and augmentation of T waves 41 months after implantation. In the other patient, an insulation defect without any clinically manifested electrical troubles was detected 50 months after implantation. Riata leads have a high incidence of insulation defects, which may be occasionally accompanied by inappropriate ICD discharges. For patients with Riata leads, careful observation of any changes in the lead-electrical measurements and a routine chest X-ray follow-up are necessary.
Lisi, Matteo; Cameli, Matteo; Mondillo, Sergio; Luzzi, Luca; Zacà, Valerio; Cameli, Paolo; Gotti, Giuseppe; Galderisi, Maurizio
2012-01-01
OBJECTIVES The present study aimed to assess the additional value of a pocket-sized imaging device (PSID) as an adjunct to plain chest X-rays in the diagnosis of pleural effusion (PE), mainly for those requiring pleural thoracentesis. METHODS We performed a thoracic ultrasound examination using a PSID in 73 patients with an abnormal chest X-ray diagnostic for unilateral PE. Abundant PE was defined as an interpleural distance between the diaphragm and visceral pleura (VP) of ≥30 mm at the apex of the 50 mm bisector line of the costodiaphragmatic recess at end expiration. RESULTS According to PSID ultrasound evaluation, abundant PE was present in 46 patients (63%), while 27 (37%) patients showed the presence of mild PE or absence of PE. Thoracentesis was performed successfully and without procedure-induced complications in all 46 patients with abundant PE. Using the above-mentioned method, we obtained a high diagnostic accuracy (area under the curve = 0.99) and excellent sensitivity and specificity of 91.7 and 99.9%, respectively, to predict a PE >1000 ml, when VP was >6.3 cm. CONCLUSIONS PSID is a useful tool that may integrate and complete the physical examination, also providing additional information to chest X-ray in the clinical management of patients with suspected PE. PSID evaluation can also increase the effectiveness and safety of thoracentesis. PMID:22815326
Koole, Olivier; Thai, Sopheak; Khun, Kim Eam; Pe, Reaksmey; van Griensven, Johan; Apers, Ludwig; Van den Ende, Jef; Mao, Tan Eang; Lynen, Lutgarde
2011-01-01
Background In 2007 WHO issued a guideline to improve the diagnosis of smear-negative and extrapulmonary tuberculosis (EPTB) in HIV-positive patients. This guideline relies heavily on the acceptance of HIV-testing and availability of chest X-rays. Methods and Findings Cohort study of TB suspects in four tuberculosis (TB) clinics in Phnom Penh, Cambodia. We assessed the operational performance of the guideline, the incremental yield of investigations, and the diagnostic accuracy for smear-negative tuberculosis in HIV-positive patients using culture positivity as reference standard. 1,147 (68.9%) of 1,665 TB suspects presented with unknown HIV status, 1,124 (98.0%) agreed to be tested, 79 (7.0%) were HIV-positive. Compliance with the guideline for chest X-rays and sputum culture requests was 97.1% and 98.3% respectively. Only 35 of 79 HIV-positive patients (44.3%) with a chest X-ray suggestive of TB started TB treatment within 10 days. 105 of 442 HIV-positive TB suspects started TB treatment (56.2% smear-negative pulmonary TB (PTB), 28.6% smear-positive PTB, 15.2% EPTB). The median time to TB treatment initiation was 5 days (IQR: 2–13 days), ranging from 2 days (IQR: 1–11.5 days) for EPTB, over 2.5 days (IQR: 1–4 days) for smear-positive PTB to 9 days (IQR: 3–17 days) for smear-negative PTB. Among the 34 smear-negative TB patients with a confirmed diagnosis, the incremental yield of chest X-ray, clinical suspicion or abdominal ultrasound, and culture was 41.2%, 17.6% and 41.2% respectively. The sensitivity and specificity of the algorithm to diagnose smear-negative TB in HIV-positive TB suspects was 58.8% (95%CI: 42.2%–73.6%) and 79.4% (95%CI: 74.8%–82.4%) respectively. Conclusions Pending point-of-care rapid diagnostic tests for TB disease, diagnostic algorithms are needed. The diagnostic accuracy of the 2007 WHO guideline to diagnose smear-negative TB is acceptable. There is, however, reluctance to comply with the guideline in terms of immediate treatment initiation. PMID:21494694
Koole, Olivier; Thai, Sopheak; Khun, Kim Eam; Pe, Reaksmey; van Griensven, Johan; Apers, Ludwig; Van den Ende, Jef; Mao, Tan Eang; Lynen, Lutgarde
2011-04-06
In 2007 WHO issued a guideline to improve the diagnosis of smear-negative and extrapulmonary tuberculosis (EPTB) in HIV-positive patients. This guideline relies heavily on the acceptance of HIV-testing and availability of chest X-rays. Cohort study of TB suspects in four tuberculosis (TB) clinics in Phnom Penh, Cambodia. We assessed the operational performance of the guideline, the incremental yield of investigations, and the diagnostic accuracy for smear-negative tuberculosis in HIV-positive patients using culture positivity as reference standard. 1,147 (68.9%) of 1,665 TB suspects presented with unknown HIV status, 1,124 (98.0%) agreed to be tested, 79 (7.0%) were HIV-positive. Compliance with the guideline for chest X-rays and sputum culture requests was 97.1% and 98.3% respectively. Only 35 of 79 HIV-positive patients (44.3%) with a chest X-ray suggestive of TB started TB treatment within 10 days. 105 of 442 HIV-positive TB suspects started TB treatment (56.2% smear-negative pulmonary TB (PTB), 28.6% smear-positive PTB, 15.2% EPTB). The median time to TB treatment initiation was 5 days (IQR: 2-13 days), ranging from 2 days (IQR: 1-11.5 days) for EPTB, over 2.5 days (IQR: 1-4 days) for smear-positive PTB to 9 days (IQR: 3-17 days) for smear-negative PTB. Among the 34 smear-negative TB patients with a confirmed diagnosis, the incremental yield of chest X-ray, clinical suspicion or abdominal ultrasound, and culture was 41.2%, 17.6% and 41.2% respectively. The sensitivity and specificity of the algorithm to diagnose smear-negative TB in HIV-positive TB suspects was 58.8% (95%CI: 42.2%-73.6%) and 79.4% (95%CI: 74.8%-82.4%) respectively. Pending point-of-care rapid diagnostic tests for TB disease, diagnostic algorithms are needed. The diagnostic accuracy of the 2007 WHO guideline to diagnose smear-negative TB is acceptable. There is, however, reluctance to comply with the guideline in terms of immediate treatment initiation.
20 CFR 718.304 - Irrebuttable presumption of total disability or death due to pneumoconiosis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... lung which: (a) When diagnosed by chest X-ray (see § 718.202 concerning the standards for X-rays and... (3) The Classification of the Pneumoconioses of the Union Internationale Contra Cancer/Cincinnati... by biopsy or autopsy, yields massive lesions in the lung; or (c) When diagnosed by means other than...
20 CFR 718.304 - Irrebuttable presumption of total disability or death due to pneumoconiosis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... lung which: (a) When diagnosed by chest X-ray (see § 718.202 concerning the standards for X-rays and... (3) The Classification of the Pneumoconioses of the Union Internationale Contra Cancer/Cincinnati... by biopsy or autopsy, yields massive lesions in the lung; or (c) When diagnosed by means other than...
20 CFR 718.304 - Irrebuttable presumption of total disability or death due to pneumoconiosis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... lung which: (a) When diagnosed by chest X-ray (see § 718.202 concerning the standards for X-rays and... (3) The Classification of the Pneumoconioses of the Union Internationale Contra Cancer/Cincinnati... by biopsy or autopsy, yields massive lesions in the lung; or (c) When diagnosed by means other than...
NASA Astrophysics Data System (ADS)
Tsuchiya, Yuichiro; Kodera, Yoshie; Tanaka, Rie; Sanada, Shigeru
2007-03-01
Early detection and treatment of lung cancer is one of the most effective means to reduce cancer mortality; chest X-ray radiography has been widely used as a screening examination or health checkup. The new examination method and the development of computer analysis system allow obtaining respiratory kinetics by the use of flat panel detector (FPD), which is the expanded method of chest X-ray radiography. Through such changes functional evaluation of respiratory kinetics in chest has become available. Its introduction into clinical practice is expected in the future. In this study, we developed the computer analysis algorithm for the purpose of detecting lung nodules and evaluating quantitative kinetics. Breathing chest radiograph obtained by modified FPD was converted into 4 static images drawing the feature, by sequential temporal subtraction processing, morphologic enhancement processing, kinetic visualization processing, and lung region detection processing, after the breath synchronization process utilizing the diaphragmatic analysis of the vector movement. The artificial neural network used to analyze the density patterns detected the true nodules by analyzing these static images, and drew their kinetic tracks. For the algorithm performance and the evaluation of clinical effectiveness with 7 normal patients and simulated nodules, both showed sufficient detecting capability and kinetic imaging function without statistically significant difference. Our technique can quantitatively evaluate the kinetic range of nodules, and is effective in detecting a nodule on a breathing chest radiograph. Moreover, the application of this technique is expected to extend computer-aided diagnosis systems and facilitate the development of an automatic planning system for radiation therapy.
[A Case of Small Intestinal Metastasis with Intussusception Due to Barium].
Tsujio, Gen; Nagahara, Hisashi; Nakao, Shigetomi; Fukuoka, Tatsunari; Shibutani, Masatsune; Maeda, Kiyoshi; Matsutani, Shinji; Kimura, Kenjiro; Toyokawa, Takahiro; Amano, Ryosuke; Tanaka, Hiroaki; Muguruma, Kazuya; Yashiro, Masakazu; Hirakawa, Kosei; Ohira, Masaichi
2017-11-01
A 48-year-old man noticed nausea and took health examination. After chest X-ray and gastrointestinal barium study was underwent, he was referred to our hospital because of abnormal shadow in the chest X-ray. CT scan revealed about 4 cm tumor in the hilum of left lung and target sign in the small intestine. He was diagnosed with intussusception and emergency operation was performed. During the laparotomy, we found 2 intussusceptions in the small intestine and we performed manual reduction using Hutchinson's maneuver. We confirmed the mass in oral side of the intussusception site but we did not confirmed any tumor in anal of the intussusception. This suggests the intussusception was caused by barium. Finally 3 small intestine tumor was observed and we resected and reconstructed each of the tumor. Histopathological examination showed small intestinal metastasis from pleomorphic carcinoma of the lung.
Zhang, Yakun; Li, Xiang; Segars, W. Paul; Samei, Ehsan
2014-01-01
Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDIvol and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality. PMID:24506654
Charbit, Jonathan; Millet, Ingrid; Maury, Camille; Conte, Benjamin; Roustan, Jean-Paul; Taourel, Patrice; Capdevila, Xavier
2015-06-01
Occult pneumothoraces (PTXs), which are not visible on chest x-ray, may progress to tension PTX. The aim of study was to establish the prevalence of large occult PTXs upon admission of patients with severe blunt trauma, according to prehospital mechanical ventilation. Patients with severe trauma consecutively admitted to our institution for 5 years were retrospectively analyzed. All patients with blunt thoracic trauma who had undergone computed tomographic (CT) within the first hour of hospitalization were included. Mechanical ventilation was considered as early if it was introduced in the prehospital period or on arrival at the hospital. Occult PTXs were defined as PTXs not visible on chest x-ray. All PTXs were measured on CT scan (largest thickness and vertical dimension). Large occult PTXs were defined by a largest thickness of 30 mm or more. Of the 526 patients studied, 395 (75%) were male, mean age was 37.9 years, mean Injury Severity Score was 22.2, and 247 (47%) received early mechanical ventilation. Of 429 diagnosed PTXs, 296 (69%) were occult. The proportion of occult PTXs classified as large was 11% (95% confidence interval, 8%-15%). The overall prevalence of large occult PTXs was 6% (95% confidence interval, 4%-8%). Both CT measurements and proportion of large occult PTXs were found statistically comparable in patients with or without mechanical ventilation. Six percent of studied patients with severe trauma had a large and occult PTX as soon as admission despite a normal chest x-ray result. The observed sizes and rates of occult PTX were comparable regardless of the initiation of early mechanical ventilation. Copyright © 2015. Published by Elsevier Inc.
Putra, I Gusti Ngurah Edi; Astuti, Putu Ayu Swandewi; Suarjana, I Ketut; Mulyawan, Ketut Hari; Duana, I Made Kerta; Kurniasari, Ni Made Dian; Putra, I Wayan Gede Artawan Eka
2018-01-01
Diabetes mellitus (DM) increases the risk of developing pulmonary tuberculosis (TB) disease. Therefore, pulmonary TB screening among DM patients is essential. This study aimed to identify factors associated with participation of DM type II patients in pulmonary TB screening using chest X-ray. This was a cross-sectional analytic study and was part of TB-DM screening study in Denpasar, Bali, Indonesia. The sample consisted of 365 DM type II patients selected by quota sampling among DM type II patients joining the screening program from January until March 2016 in 11 public health centres in Denpasar. Data were collected via structured interviews. The contributing factors were determined by modified Poisson regression test for cross-sectional data. From the findings, less than half (45.48%) of DM type II patients participated in chest X-ray examination for TB. Factors associated with participation in pulmonary TB screening were having a higher educational level [APR = 1.34, 95% CI (1.07-1.67)], having family member who developed pulmonary TB disease [APR = 1.47, 95% CI (1.12-1.93)], the travel time to referral hospital for screening being ≤ 15 minutes [APR = 1.6, 95% CI (1.26-2.03)], having health insurance [APR = 2.69, 95% CI (1.10-6.56)], and receiving good support from health provider [APR = 1.35, 95% CI (1.06-1.70)]. Therefore, training for health provider on providing counselling, involvement of family members in screening process, and improving the health insurance coverage and referral system are worth considering.
Paediatric chest wall trauma causing delayed presentation of ventricular arrhythmia.
Tegethoff, Angela M; Raney, Emerald; Mendelson, Jenny; Minckler, Michael R
2017-07-24
This report describes a paediatric patient presenting with haemodynamically stable non-sustained ventricular tachycardia 1 day after minor blunt chest trauma. Initial laboratory studies, chest X-ray and echocardiography were normal; however, cardiac MRI revealed precordial haematoma, myocardial contusion and small pericardial effusion. Throughout her hospital course, she remained asymptomatic aside from frequent couplets and triplets of premature ventricular contractions. Ectopy was controlled with oral verapamil. This case highlights how significant cardiac injury may be missed with standard diagnostic algorithms. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Longest delayed hemothorax reported after blunt chest injury.
Yap, Darren; Ng, Miane; Chaudhury, Madhu; Mbakada, Nik
2018-01-01
Blunt chest injury is a common presentation to the emergency department. However, a delayed hemothorax after blunt trauma is rare; current literature reports a delay of up to 30days. We present a case of 44-day delay in hemothorax which has not been previously reported in current literature. A 52-year-old Caucasian male first presented to the emergency department complaining of persistent right sided chest pain 2weeks after having slipped on a wet surface at home. His initial chest X-ray showed fractures of the right 7th and 8th ribs without a hemothorax or pneumothorax. He returned 30days after the initial consultation (44days post-trauma) having increasing shortness of breath. A chest X-ray this time revealed a large right hemothorax and 1850ml of blood drained from his chest. There was a complete resolution of the hemothorax within 48h and the patient was discharged after a 6-week follow-up with the chest physicians. Delayed hemothorax after blunt trauma is a rare clinical occurrence but associated with significant morbidity and mortality. The management of delayed hemothorax includes draining the hemothorax and controlling the bleeding. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be vigilant and weary that hemothorax could be a possibility after a chest injury despite a delay in presentation. A knowledge of delayed hemothorax will prompt physicians in providing important advice, warning signs and information to patients after a chest injury to avoid a delay in seeking medical attention. Copyright © 2017 Elsevier Inc. All rights reserved.
İnal, Tolga; Ataç, Gökçe
2014-01-01
We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.
Dose evaluation in paediatric patients undergoing chest X-ray examinations
NASA Astrophysics Data System (ADS)
Piantini, F.; Schelin, H. R.; Denyak, V.; Bunick, A. P.; Legnani, A.; Ledesma, J. A.; Filipov, D.; Paschuk, S. A.
2017-11-01
This study aimed to estimate the incident air kerma in chest X-ray examinations, for lateral (LAT) and anterior-posterior (AP) (together with posterior-anterior (PA)) projections, in one of the largest paediatric hospitals in Brazil, and to compare these with the results obtained in a general hospital of the same city. The dosimetric results were analysed along with the patient characteristics and radiographer strategies. The examinations of 225 (119 male and 106 female) patients were studied and 389 X-ray scans (200 AP/PA projections and 189 LAT projections) of paediatric patients were acquired. For analysis of the results, the patients were divided into the following age groups: 0-1 y, 1-5 y, 5-10 y, and 10-15 y. Patient's thickness can be determined from age, height or weight with an uncertainty of 20-30%. In different hospitals, the difference in patient's thicknesses between the same age groups can reach 25-55%. A minimal correlation between the patient dose and thickness was observed, with a 4-fold difference in the dose for patients of the same thickness. By standardizing radiological protocols, it should be possible to keep the dose within intervals of 50-100 μGy for LAT projection and 40-80 μGy for AP/PA projection.
Radiological Findings in a case of Advance staged Mesothelioma
Aziz, Fahad
2009-01-01
Chest X Ray is the initial screening test for the mesothelioma like all other the chest diseases. But computed tomography (CT) is the imaging technique of choice for charactering pleural masses. CT also gives important information regarding invasion of the chest wall and surrounding structures. Certain CT features help differentiate benign from malignant processes. This short article highlights the salient CT appearance of mesothelioma; the most common pleural tumor. PMID:22263002
Angular relational signature-based chest radiograph image view classification.
Santosh, K C; Wendling, Laurent
2018-01-22
In a computer-aided diagnosis (CAD) system, especially for chest radiograph or chest X-ray (CXR) screening, CXR image view information is required. Automatically separating CXR image view, frontal and lateral can ease subsequent CXR screening process, since the techniques may not equally work for both views. We present a novel technique to classify frontal and lateral CXR images, where we introduce angular relational signature through force histogram to extract features and apply three different state-of-the-art classifiers: multi-layer perceptron, random forest, and support vector machine to make a decision. We validated our fully automatic technique on a set of 8100 images hosted by the U.S. National Library of Medicine (NLM), National Institutes of Health (NIH), and achieved an accuracy close to 100%. Our method outperforms the state-of-the-art methods in terms of processing time (less than or close to 2 s for the whole test data) while the accuracies can be compared, and therefore, it justifies its practicality. Graphical Abstract Interpreting chest X-ray (CXR) through the angular relational signature.
Goodacre, Steve; Horspool, Kimberley; Nelson-Piercy, Catherine; Knight, Marian; Shephard, Neil; Lecky, Fiona; Thomas, Steven; Hunt, Beverley; Fuller, Gordon
2017-12-01
To determine whether clinical features (in the form of a clinical decision rule) or d-dimer can be used to select pregnant or postpartum women with suspected PE for diagnostic imaging. Observational cohort study augmented with additional cases. Consultant-led maternity units participating in the UK Obstetric Surveillance System (UKOSS) and emergency departments and maternity units at eleven prospectively recruiting sites. 198 pregnant or postpartum women with diagnosed PE identified through UKOSS and 324 pregnant or postpartum women with suspected PE from prospectively recruiting sites. Data were collected relating to clinical features, elements of clinical decision rules, d-dimer measurements, diagnostic imaging, treatment for PE and adverse outcomes. Women were classified as having or not having PE on the basis of diagnostic imaging, treatment and subsequent adverse outcomes. Primary analysis was limited to women with conclusive diagnostic imaging. Secondary analyses included women with clinically diagnosed or ruled out PE. The primary analysis included 181 women with PE and 259 without. Most clinical features showed no association with PE. The only exceptions were number of previous pregnancies over 24 weeks (p=0.017), no varicose veins (p=0.045), no recent long haul travel (p=0.006), recent surgery including caesarean section (p=0.001), increased temperature (p=0.003), low oxygen saturation (p<0.001), PE-related chest x-ray abnormality (p=0.01) and other chest x-ray abnormality (p=0.001).Clinical decision rules had areas under the receiver-operator characteristic curve ranging from 0.577 to 0.732. No clinically useful threshold for decision-making was identified for any rule. The sensitivities and specificities of d-dimer were 88.4% and 8.8% using the standard laboratory threshold and 69.8% and 32.8% using a pregnancy-specific threshold. Clinical decision rules, d-dimer and chest x-ray should not be used to select pregnant or postpartum women with suspected PE for diagnostic imaging. © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Conceptus radiation dose and risk from chest screen-film radiography.
Damilakis, John; Perisinakis, Kostas; Prassopoulos, Panos; Dimovasili, Evangelia; Varveris, Haralambos; Gourtsoyiannis, Nicholas
2003-02-01
The objectives of the present study were to (a) estimate the conceptus radiation dose and risks for pregnant women undergoing posteroanterior and anteroposterior (AP) chest radiographs, (b) study the conceptus dose as a function of chest thickness of the patient undergoing chest radiograph, and (c) investigate the possibility of a conceptus to receive a dose of more than 10 mGy, the level above which specific measurements of conceptus doses may be necessary. Thermoluminescent dosimeters were used for dose measurements in anthropomorphic phantoms simulating pregnancy at the three trimesters of gestation. The effect of chest thickness on conceptus dose and risk was studied by adding slabs of lucite on the anterior and posterior surface of the phantom chest. The conceptus risk for radiation-induced childhood fatal cancer and hereditary effects was calculated based on appropriate risk factors. The average AP chest dimension (d(a)) was estimated for 51 women of childbearing age from chest CT examinations. The value of d(a) was estimated to be 22.3 cm (17.4-27.2 cm). The calculated maximum conceptus dose was 107 x 10(-3) mGy for AP chest radiographs performed during the third trimester of pregnancy with maternal chest thickness of 27.2 cm. This calculation was based on dose data obtained from measurements in the phantoms and d(a) estimated from the patient group. The corresponding average excess of childhood cancer was 10.7 per million patients. The risk for hereditary effects was 1.1 per million births. Radiation dose for a conceptus increases exponentially as chest thickness increases. The conceptus dose at the third trimester is higher than that of the second and first trimesters. The results of the current study suggest that chest radiographs carried out in women at any time during gestation will result in a negligible increase in risk of radiation-induced harmful effects to the unborn child. After a properly performed maternal chest X-ray, there is no need for individual conceptus dose estimations.
2011-02-10
DesigneD for clinicians involved in the management of acutely ill patients, this book enables them to recognise quickly the appearance of life-threatening conditions. It also concentrates on the interpretation of plain chest and abdominal images.
Radiation exposure from work-related medical X-rays at the Portsmouth Naval Shipyard.
Daniels, Robert D; Kubale, Travis L; Spitz, Henry B
2005-03-01
Previous analyses suggest that worker radiation dose may be significantly increased by routine occupational X-ray examinations. Medical exposures are investigated for 570 civilian workers employed at the Portsmouth Naval Shipyard (PNS) at Kittery, Maine. The research objective was to determine the radiation exposure contribution of work-related chest X-rays (WRX) relative to conventional workplace radiation sources. Methods were developed to estimate absorbed doses to the active (hematopoietic) bone marrow from X-ray examinations and workplace exposures using data extracted from worker dosimetry records (8,468) and health records (2,453). Dose distributions were examined for radiation and non-radiation workers. Photofluorographic chest examinations resulted in 82% of the dose from medical sources. Radiation workers received 26% of their collective dose from WRX and received 66% more WRX exposure than non-radiation workers. WRX can result in a significant fraction of the total dose, especially for radiation workers who were more likely to be subjected to routine medical monitoring. Omission of WRX from the total dose is a likely source of bias that can lead to dose category misclassification and may skew the epidemiologic dose-response assessment for cancers induced by the workplace.
NASA Astrophysics Data System (ADS)
Anavi, Yaron; Kogan, Ilya; Gelbart, Elad; Geva, Ofer; Greenspan, Hayit
2016-03-01
We explore the combination of text metadata, such as patients' age and gender, with image-based features, for X-ray chest pathology image retrieval. We focus on a feature set extracted from a pre-trained deep convolutional network shown in earlier work to achieve state-of-the-art results. Two distance measures are explored: a descriptor-based measure, which computes the distance between image descriptors, and a classification-based measure, which performed by a comparison of the corresponding SVM classification probabilities. We show that retrieval results increase once the age and gender information combined with the features extracted from the last layers of the network, with best results using the classification-based scheme. Visualization of the X-ray data is presented by embedding the high dimensional deep learning features in a 2-D dimensional space while preserving the pairwise distances using the t-SNE algorithm. The 2-D visualization gives the unique ability to find groups of X-ray images that are similar to the query image and among themselves, which is a characteristic we do not see in a 1-D traditional ranking.
Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B
2017-12-01
To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (p<0.001), longer transparenchymal distance (p<0.001), and prone position (p=0.027). There was positive correlation between the need for chest tube placement and longer transparenchymal distance (p=0.007) and smaller lesion diameter (p=0.018). Lesions in the left lower lobe had the lowest rates of pneumothorax (p=0.008) and chest tube drainage (p=0.018). Patients whose pneumothoraces were diagnosed on the follow-up chest X-ray, but not on the immediate post-procedural CT scan had significantly higher requirement for chest tube drainage (p=0.039). CT-guided lung biopsy has a high rate of technical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Neal, Richard D; Barham, Allan; Bongard, Emily; Edwards, Rhiannon Tudor; Fitzgibbon, Jim; Griffiths, Gareth; Hamilton, Willie; Hood, Kerenza; Nelson, Annmarie; Parker, David; Porter, Cath; Prout, Hayley; Roberts, Kirsty; Rogers, Trevor; Thomas-Jones, Emma; Tod, Angela; Yeo, Seow Tien; Hurt, Chris N
2017-01-01
Background: Achieving earlier stage diagnosis is one option for improving lung cancer outcomes in the United Kingdom. Patients with lung cancer typically present with symptoms to general practitioners several times before referral or investigation. Methods: We undertook a mixed methods feasibility individually randomised controlled trial (the ELCID trial) to assess the feasibility and inform the design of a definitive, fully powered, UK-wide, Phase III trial of lowering the threshold for urgent investigation of suspected lung cancer. Patients over 60, with a smoking history, presenting with new chest symptoms to primary care, were eligible to be randomised to intervention (urgent chest X-ray) or usual care. Results: The trial design and materials were acceptable to GPs and patients. We randomised 255 patients from 22 practices, although the proportion of eligible patients who participated was lower than expected. Survey responses (89%), and the fidelity of the intervention (82% patients X-rayed within 3 weeks) were good. There was slightly higher anxiety and depression in the control arm in participants aged >75. Three patients (1.2%) were diagnosed with lung cancer. Conclusions: We have demonstrated the feasibility of individually randomising patients at higher risk of lung cancer, to a trial offering urgent investigation or usual care. PMID:28072761
TH-AB-209-08: Next Generation Dedicated 3D Breast Imaging with XACT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, S; Chen, J; Samant, P
Purpose: Exposure to radiation increases the risk of cancer. We have designed a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, an X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to conventional breast CT. Methods: Theoretical calculations are done to determine the appropriate X-ray energy and ultrasound frequency in breast XACT imaging. A series of breast CT image along the coronal plane from a patient with calcifications in the breast tissue are used as the source image. HU value based segmentation ismore » done to distinguish the skin, adipose tissue, glandular tissue, breast calcification, and chest bone from each CT image. X-ray dose deposition in each pixel is calculated based on the tissue type by using GEANT4 Monte Carlo toolkits. The initial pressure rise caused by X-ray energy deposition is calculated according to tissue properties. Then, the X-ray induced acoustic wave propagation is simulated by K-WAVE toolkit. Breast XACT images are reconstructed from the recorded time-dependent ultrasound waves. Results: For imaging a breast with large size (16cm in diameter at chest wall), the photon energy of X-ray source and the central frequency of ultrasound detector is determined as 20keV and 5.5MHz. Approximately 10 times contrast between a calcification and the breast tissue can be acquire from XACT image. The calcification can be clearly identified from the reconstructed XACT image. Conclusion: XACT technique takes the advantages of X-ray absorption contrast and high ultrasonic resolution. With the proposed innovative technology, one can potentially reduce radiation dose to patient in 3D breast imaging as compared with current x-ray modalities, while still maintaining high imaging contrast and spatial resolution.« less
Gray-scale transform and evaluation for digital x-ray chest images on CRT monitor
NASA Astrophysics Data System (ADS)
Furukawa, Isao; Suzuki, Junji; Ono, Sadayasu; Kitamura, Masayuki; Ando, Yutaka
1997-04-01
In this paper, an experimental evaluation of a super high definition (SHD) imaging system for digital x-ray chest images is presented. The SHD imaging system is proposed as a platform for integrating conventional image media. We are involved in the use of SHD images in the total digitizing of medical records that include chest x-rays and pathological microscopic images, both which demand the highest level of quality among the various types of medical images. SHD images use progressive scanning and have a spatial resolution of 2000 by 2000 pixels or more and a temporal resolution (frame rate) of 60 frames/sec or more. For displaying medical x-ray images on a CRT, we derived gray scale transform characteristics based on radiologists' comments during the experiment, and elucidated the relationship between that gray scale transform and the linearization transform for maintaining the linear relationship with the luminance of film on a light box (luminance linear transform). We then carried out viewing experiments based on a five-stage evaluation. Nine radiologists participated in our experiment, and the ten cases evaluated included pulmonary fibrosis, lung cancer, and pneumonia. The experimental results indicated that conventional film images and those on super high definition CRT monitors have nearly the same quality. They also show that the gray scale transform for CRT images decided according to radiologists' comments agrees with the luminance linear transform in the high luminance region. And in the low luminance region, it was found that the gray scale transform had the characteristics of level expansion to increase the number of levels that can be expressed.
The non-specificity of the left/right ventricular amplitude ratio (LV/RV) for mitral insufficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Preston, D.F.; Reinsel, M.S.; Martin, N.L.
1984-01-01
The purpose of this study was to determine the specificity of the LV/RV for mitral insufficiency. One hundred and sixty patients underwent MUGA studies as part of their diagnostic evaluation. Phase analysis was performed. In the amplitude image, the LV/RV was measured. Patients were divided into 11 clinical groups based on chart review after adequate follow-up. The groups were compared by Duncan's Multiple Comparsion Test. Patients with mitral insufficiency (N = 12, mean LV/RV = 2.36), those with idiopathic myocardiopathy (8, 2.29) and those with normal hearts having lung disease on chest x-ray (22, 1.78) formed a group which atmore » the p < .05 level were not different from one another. Patients with idiopathic myocardiography, normal hearts with lung disease on chest x-ray, normal hearts with lung disease (23, 1.71) formed a second group which partially overlapped with both the first and third groups. The third group consisted of normal hearts with lung disease, normal hearts not taking adriamycin (18, 1.53), normal hearts taking adriamycin (22, 1.50), congestive heart failure (19, 1.50), arteriosclerotic heart disease, normal hearts (15, 1.29), chronic obstructive pulmonary disease and acute myocardial infarction. The LV/RV is not specific for mitral insufficiency. Idiopathic myocardiography, and normal hearts with lung disease on chest x-ray (metastases, cancer of the lung, infiltrates, fibrosis, and/or COPD) cannot be differentiated on a statistical basis. The mitral insufficiency group had the greatest values of LV/RV. It appears that decreased RV amplitude seen with diseases causing strain on the right ventricle will result in elevated LV/RV ratios.« less
Watanabe, Kentaro; Ohara, Makoto; Suzuki, Tatsuya; Ouchi, Motoshi; Suzuki, Kazunari; Hashimoto, Masao; Saigusa, Taro; Aoyama, Junya; Nakano, Hiroshi; Oba, Kenzo
2013-01-01
This study aimed to evaluate the relationship between aortic arch calcification (AAC) detectable on chest X-ray films and plasma diacron-reactive oxygen metabolites (d-ROMs) in patients with type 2 diabetes but without cardiovascular disease. Forty-nine patients with type 2 diabetes but without cardiovascular disease were evaluated with chest X-ray examinations and divided into those with AAC (n=26) and those without AAC (n=23). Biochemical variables, including plasma levels of d-ROMS, high-sensitivity C-reactive protein (hsCRP), plasminogen activator inhibitor-1 (PAI-1), and lipoprotein(a) (Lp(a)), were evaluated after an overnight fast. The relationships of AAC with both inflammation and oxidative-stress variables were evaluated. The plasma level of d-ROMs in subjects with AAC was significantly higher than that in subjects without AAC, whereas plasma levels of hsCRP, PAI-1, and Lp(a) in subjects with AAC were higher, but not significantly so, than those in subjects without AAC. Multivariate linear regression analysis with AAC grade as the dependent variable and plasma levels of d-ROMs, hsCRP, PAI-1, or Lp(a) as independent variables demonstrated a significant association of AAC grade with plasma levels of d-ROMs but not with plasma levels of hsCRP, PAI-1, or Lp(a). The plasma level of d-ROMs is associated with AAC in patients with type 2 diabetes but without cardiovascular disease. Hence, the results of the present study suggest that AAC in these patients is strongly associated with oxidative stress. Furthermore, patients with type 2 diabetes and AAC may be at high risk for the development and progression of various diabetic complications induced by oxidative stress.
Kea, Bory; Gamarallage, Ruwan; Vairamuthu, Hemamalini; Fortman, Jonathan; Lunney, Kevin; Hendey, Gregory W; Rodriguez, Robert M
2013-08-01
Computed tomography (CT) has been shown to detect more injuries than plain radiography in patients with blunt trauma, but it is unclear whether these injuries are clinically significant. This study aimed to determine the proportion of patients with normal chest x-ray (CXR) result and injury seen on CT and abnormal initial CXR result and no injury on CT and to characterize the clinical significance of injuries seen on CT as determined by a trauma expert panel. Patients with blunt trauma older than 14 years who received emergency department chest imaging as part of their evaluation at 2 urban level I trauma centers were enrolled. An expert trauma panel a priori classified thoracic injuries and subsequent interventions as major, minor, or no clinical significance. Of 3639 participants, 2848 (78.3%) had CXR alone and 791 (21.7%) had CXR and chest CT. Of 589 patients who had chest CT after a normal CXR result, 483 (82.0% [95% confidence interval [CI], 78.7-84.9%]) had normal CT results, and 106 (18.0% [95% CI, 15.1%-21.3%]) had CTs diagnosing injuries-primarily rib fractures, pulmonary contusion, and incidental pneumothorax. Twelve patients had injuries classified as clinically major (2.0% [95% CI, 1.2%-3.5%]), 78 were clinically minor (13.2% [95% CI, 10.7%-16.2%]), and 16 were clinically insignificant (2.7% (95% CI, 1.7%-4.4%]). Of 202 patients with CXRs suggesting injury, 177 (87.6% [95% CI, 82.4%-91.5%]) had chest CTs confirming injury and 25 (12.4% [95% CI, 8.5%-17.6%]) had no injury on CT. Chest CT after a normal CXR result in patients with blunt trauma detects injuries, but most do not lead to changes in patient management. Copyright © 2013 Elsevier Inc. All rights reserved.
Late clotted haemothorax after blunt chest trauma.
Sinha, P; Sarkar, P
1998-01-01
A clotted haemothorax can develop any time after blunt chest trauma. Two cases are described in which late clotted haemothoraces developed which were treated by limited thoracotomy and evacuation of clots. Late clotted haemothorax may occur even in the absence of any abnormal initial clinical findings. Early detection and treatment is important to avoid the complications of fibrothorax and empyema with permanent pulmonary dysfunction. After blunt chest trauma patients should be advised to return to the accident and emergency department for assessment on development of any new chest symptom. Under these circumstances a chest x ray is mandatory to exclude a haemothorax. Images Figure 1 PMID:9639184
X-Ray Phantom Development For Observer Performance Studies
NASA Astrophysics Data System (ADS)
Kelsey, C. A.; Moseley, R. D.; Mettler, F. A.; Parker, T. W.
1981-07-01
The requirements for radiographic imaging phantoms for observer performance testing include realistic tasks which mimic at least some portion of the diagnostic examination presented in a setting which approximates clinically derived images. This study describes efforts to simulate chest and vascular diseases for evaluation of conventional and digital radiographic systems. Images of lung nodules, pulmonary infiltrates, as well as hilar and mediastinal masses are generated with a conventional chest phantom to make up chest disease test series. Vascular images are simulated by hollow tubes embedded in tissue density plastic with widening and narrowing added to mimic aneurysms and stenoses. Both sets of phantoms produce images which allow simultaneous determination of true positive and false positive rates as well as complete ROC curves.
Is chest x-ray an adequate screening tool for the diagnosis of blunt thoracic aortic injury?
Ekeh, Akpofure Peter; Peterson, Wylan; Woods, Randy J; Walusimbi, Mbaga; Nwuneli, Nancy; Saxe, Jonathan M; McCarthy, Mary C
2008-11-01
Blunt thoracic aortic injuries (BTAI) have a high mortality rate. For survivors, chest X-ray (CXR) findings are used to determine the need for further diagnostic testing with chest computerized tomography with angiography (CTA) or conventional angiography. We set to determine the adequacy of utilizing CXR alone as a screening tool for BTAI. All patients diagnosed with BTAI at a level I trauma-center during a 7-year-period were identified. CXRs of these patients and those of a control group of blunt trauma patients with an injury severity score >15 were reviewed by four trauma surgeons blinded to the diagnosis. Based on each CXR viewed, the surgeons decided if they would have proceeded to chest CTA, angiography, or required no further studies to rule out BTAI. In the 7-year-period, 83 patients had BTAI. CXRs were available in 45 patients. The four surgeons viewed 96 CXRs including those of 51 controls. Based on the CXR appearance in patients with BTAI, the surgeons chose to proceed to chest CTA in 38 patients (84.4%), conventional aortography in two patients (4.4%), and no further testing in five patients (11.2%). A widened mediastinum (75%) and loss of the aorto-pulmonary window (40%) were the most frequent CXR abnormalities. Patients with BTAI were more likely to have an abnormal CXR-40 of 45 (88.8%) patients when compared with the controls-25 of 51 (49%)patients-p < 0.001. Although CXR is a sensitive screening modality, it failed to identify the possibility of BTAI in 11% of patients. The liberal use of chest CTA after high speed motor vehicle crashes is recommended to minimize the incidence of missed BTAI.
[The preoperative thoracic X-ray for tactical decisions for the thoracic injuries treatment].
Voskresenskiĭ, O V; Beresneva, É A; Sharifullin, F A; Popova, I E; Abakumov, M M
2011-01-01
Data of 379 patients with penetrating thoracic wounds were analyzed. The pathologic changes on X-ray of the thoracic cavity were registered 239 (63,1%) patients: the hemothorax was diagnosed in 44,3%, pneumothorax - in 26,8% and hemopneumothorax - in 28,9%. 154 patients had videothoracoscopic surgery and 225 patients were operated on using traditional open methods. Operative findings were compared with X-ray data. The sensitivity of plain chest radiography in diagnostics of hemothorax was 52,1%, the specificity - 92,1%. Mistakes of interpreting X-ray data in diagnosing of low-volume hemo- or pneumothorax were defined. The computed tomography of the thorax proved to be the most precise means of intrapleural injuries diagnostics. The optimal algorithm of preoperative thoracic X-ray was suggested.
High performance x-ray anti-scatter grid
Logan, Clinton M.
1995-01-01
An x-ray anti-scatter grid for x-ray imaging, particularly for screening mammography, and method for fabricating same, x-rays incident along a direct path pass through a grid composed of a plurality of parallel or crossed openings, microchannels, grooves, or slots etched in a substrate, such as silicon, having the walls of the microchannels or slots coated with a high opacity material, such as gold, while x-rays incident at angels with respect to the slots of the grid, arising from scatter, are blocked. The thickness of the substrate is dependent on the specific application of the grid, whereby a substrate of the grid for mammography would be thinner than one for chest radiology. Instead of coating the walls of the slots, such could be filed with an appropriate liquid, such as mercury.
[Gonad protective effect of radiation protective apron in chest radiography].
Hashimoto, Masatoshi; Kato, Hideyuki; Fujibuchi, Toshiou; Ochi, Shigehiro; Morita, Fuminori
2004-12-01
Depending on the facility, a radiation protective apron (protector) is used to protect the gonad from radiation exposure in chest radiography. To determine the necessity of using a protector during chest radiography, we measured the effect of the protector on the gonad in this study. First, using a human body phantom, we measured the absorbed dose of the female gonad with and without the protector, using a thermoluminescence dosimeter (TLD), and confirmed its protective effect. Using the protector, the absorbed dose was reduced to 28+/-2% and 39+/-4% for field sizes of 14 x 17 inch and 14 x 14 inch, respectively. Next, we used Monte Carlo simulation and confirmed, not only the validity of the actual measurement values, but also the fact that the influence of radiation on the absorbed dose of the gonad was mostly from scattered radiation from inside the body for the 14 x 17 inch field size, and also from the X-ray tube for the 14 x 14 inch field size. Although a certain protective effect is achieved by using the protector, the radiation dose to the gonad is only a few microGy even without a protector. Thus, the risk of a genetic effect would be as small as 10(-8). Given that acceptable risk is below 10(-6), we conclude the use of a radiation protective apron is not necessary for diagnostic chest radiography.
Unsupervised segmentation of lungs from chest radiographs
NASA Astrophysics Data System (ADS)
Ghosh, Payel; Antani, Sameer K.; Long, L. Rodney; Thoma, George R.
2012-03-01
This paper describes our preliminary investigations for deriving and characterizing coarse-level textural regions present in the lung field on chest radiographs using unsupervised grow-cut (UGC), a cellular automaton based unsupervised segmentation technique. The segmentation has been performed on a publicly available data set of chest radiographs. The algorithm is useful for this application because it automatically converges to a natural segmentation of the image from random seed points using low-level image features such as pixel intensity values and texture features. Our goal is to develop a portable screening system for early detection of lung diseases for use in remote areas in developing countries. This involves developing automated algorithms for screening x-rays as normal/abnormal with a high degree of sensitivity, and identifying lung disease patterns on chest x-rays. Automatically deriving and quantitatively characterizing abnormal regions present in the lung field is the first step toward this goal. Therefore, region-based features such as geometrical and pixel-value measurements were derived from the segmented lung fields. In the future, feature selection and classification will be performed to identify pathological conditions such as pulmonary tuberculosis on chest radiographs. Shape-based features will also be incorporated to account for occlusions of the lung field and by other anatomical structures such as the heart and diaphragm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mothiram, Ursula; Brennan, Patrick C; Robinson, John
2013-12-15
Following X-ray exposure, radiographers receive immediate feedback on detector exposure in the form of the exposure index (EI). To identify whether radiographers are meeting manufacturer-recommended EI (MREI) ranges for routine chest, abdomen and pelvis X-ray examinations under a variety of conditions and to examine factors affecting the EI. Data on 5000 adult X-ray examinations including the following variables were collected: examination parameters, EI values, patient gender, date of birth, date and time of examination, grid usage and the presence of implant or prosthesis. Descriptive statistics were used to summarize each data set and the Mann–Whitney U test was used tomore » determine significant differences, with P < 0.05 indicating significance for all tests. Most examinations demonstrated EI values that were outside the MREI ranges, with significantly higher median EI values recorded for female patient radiographs than those for male patients for all manufacturers, indicating higher detector exposures for all units except for Philips digital radiography (DR), where increased EI values indicate lower exposure (P = 0.01). Median EI values for out of hours radiography were also significantly higher compared with normal working hours for all technologies (P ≤ 0.02). Significantly higher median EI values were demonstrated for Philips DR chest X-rays without as compared to those with the employment of a grid (P = 0.03), while significantly lower median EI values were recorded for Carestream Health computed radiography (CR) chest X-rays when an implant or prosthesis was present (P = 0.02). Non-adherence to MREIs has been demonstrated with EI value discrepancies being dependent on patient gender, time/day of exposure, grid usage and the presence of an implant or prosthesis. Retrospective evaluation of EI databases is a valuable tool to assess the need of quality improvement in routine DR.« less
[Characteristics of specifications of transportable inverter-type X-ray equipment].
Yamamoto, Keiichi; Miyazaki, Shigeru; Asano, Hiroshi; Shinohara, Fuminori; Ishikawa, Mitsuo; Ide, Toshinori; Abe, Shinji; Negishi, Toru; Miyake, Hiroyuki; Imai, Yoshio; Okuaki, Tomoyuki
2003-07-01
Our X-ray systems study group measured and examined the characteristics of four transportable inverter-type X-ray equipments. X-ray tube voltage and X-ray tube current were measured with the X-ray tube voltage and the X-ray tube current measurement terminals provided with the equipment. X-ray tube voltage, irradiation time, and dose were measured with a non-invasive X-ray tube voltage-measuring device, and X-ray output was measured by fluorescence meter. The items investigated were the reproducibility and linearity of X-ray output, error of pre-set X-ray tube voltage and X-ray tube current, and X-ray tube voltage ripple percentage. The waveforms of X-ray tube voltage, the X-ray tube current, and fluorescence intensity draw were analyzed using the oscilloscope gram and a personal computer. All of the equipment had a preset error of X-ray tube voltage and X-ray tube current that met JIS standards. The X-ray tube voltage ripple percentage of each equipment conformed to the tendency to decrease when X-ray tube voltage increased. Although the X-ray output reproducibility of system A exceeded the JIS standard, the other systems were within the JIS standard. Equipment A required 40 ms for X-ray tube current to reach the target value, and there was some X-ray output loss because of a trough in X-ray tube current. Owing to the influence of the ripple in X-ray tube current, the strength of the fluorescence waveform rippled in equipments B and C. Waveform analysis could not be done by aliasing of the recording device in equipment D. The maximum X-ray tube current of transportable inverter-type X-ray equipment is as low as 10-20 mA, and the irradiation time of chest X-ray photography exceeds 0.1 sec. However, improvement of the radiophotographic technique is required for patients who cannot move their bodies or halt respiration. It is necessary to make the irradiation time of the equipments shorter for remote medical treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yakun; Li, Xiang; Segars, W. Paul
2014-02-15
Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definiummore » 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.« less
NASA Astrophysics Data System (ADS)
Dance, David R.; McVey, Graham; Sandborg, Michael P.; Persliden, Jan; Carlsson, Gudrun A.
1999-05-01
A Monte Carlo program has been developed to model X-ray imaging systems. It incorporates an adult voxel phantom and includes anti-scatter grid, radiographic screen and film. The program can calculate contrast and noise for a series of anatomical details. The use of measured H and D curves allows the absolute calculation of the patient entrance air kerma for a given film optical density (or vice versa). Effective dose can also be estimated. In an initial validation, the program was used to predict the optical density for exposures with plastic slabs of various thicknesses. The agreement between measurement and calculation was on average within 5%. In a second validation, a comparison was made between computer simulations and measurements for chest and lumbar spine patient radiographs. The predictions of entrance air kerma mostly fell within the range of measured values (e.g. chest PA calculated 0.15 mGy, measured 0.12 - 0.17 mGy). Good agreement was also obtained for the calculated and measured contrasts for selected anatomical details and acceptable agreement for dynamic range. It is concluded that the program provides a realistic model of the patient and imaging system. It can thus form the basis of a detailed study and optimization of X-ray imaging systems.
İnal, Tolga; Ataç, Gökçe
2014-01-01
PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331
Code of Federal Regulations, 2010 CFR
2010-04-01
... be a single postero-anterior projection at full inspiration on a 14 by 17 inch film. Additional chest films or views shall be obtained if they are necessary for clarification and classification. The film... source or focal spot to film distance shall be at least 6 feet; (iii) Only medium-speed film and medium...
... treated. The person may receive: Blood and urine tests. Breathing support, including a tube through the mouth into the lungs, and a breathing machine (ventilator). Chest x-ray. Endoscopy -- camera placed down ...
Man in his 50s with chest pain and dyspnoea.
Obayashi, Yuki; Izumi, Chisato; Nakagawa, Yoshihisa
2018-05-01
A man in his 50s with sudden-onset chest pain and dyspnoea was transferred to the emergency room. He had a history of aortic valve replacement due to aortic regurgitation with a mechanical valve 6 years previously. Heart rate was 90 bpm, and blood pressure was too low to measure. In the emergency room, he presented with severe dyspnoea and a chest X-ray showed severe lung congestion (figure 1A). ECG showed complete left bundle branch block. His respiratory status rapidly worsened, and he went into cardiopulmonary arrest. After cardiopulmonary resuscitation, transthoracic echocardiography was performed (figure 1B, online supplementary video 1).DC1SP110.1136/heartjnl-2017-312477.supp1Supplementary file 1 heartjnl;104/10/868/F1F1F1Figure 1(A) Chest X-ray. (B) Colour Doppler image from apical five-chamber view. What is the most likely cause of the patient's cardiopulmonary arrest?Myocardial infarction in left main trunkAortic dissectionProsthetic valve thrombosisProsthetic valve embolisationPulmonary embolism. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
The utility of chest X-ray as a screening tool for blunt thoracic aortic injury.
Gutierrez, Adam; Inaba, Kenji; Siboni, Stefano; Effron, Zachary; Haltmeier, Tobias; Jaffray, Paul; Reddy, Sravanthi; Lofthus, Alexander; Benjamin, Elizabeth; Dubose, Joseph; Demetriades, Demetrios
2016-01-01
The early and accurate identification of patients with blunt thoracic aortic injury (BTAI) remains a challenge. Traditionally, a portable AP chest X-ray (CXR) is utilized as the initial screening modality for BTAI, however, there is controversy surrounding its sensitivity. The purpose of this study was to assess the sensitivity of CXR as a screening modality for BTAI. After IRB approval, all adult (≥18 yo) blunt trauma patients admitted to LAC+USC (01/2011-12/2013) who underwent CXR and chest CT were retrospectively reviewed. Final radiology attending CXR readings were reviewed for mediastinal abnormalities (widened mediastinum, mediastinal to chest width ratio greater than 0.25, irregular aortic arch, blurred aortic contour, opacification of the aortopulmonary window, and apical pleural haematoma) suggestive of aortic injury. Chest CT final attending radiologist readings were utilized as the gold standard for diagnosis of BTAI. The primary outcome analyzed was CXR sensitivity. A total of 3728 patients were included in the study. The majority of patients were male (72.6%); mean age was 43 (SD 20). Median ISS was 9 (IQR 4-17) and median GCS was 15 (IQR 14-15). The most common mechanism of injury was MVC (48.0%), followed by fall (20.6%), and AVP (16.9%). The total number of CXRs demonstrating a mediastinal abnormality was 200 (5.4%). Widened mediastinum was present on 191 (5.1%) of CXRs, blurred aortic contour on 10 (0.3%), and irregular aortic arch on 4 (0.1%). An acute aortic injury confirmed by chest CT was present in 17 (0.5%) patients. Only 7 of these with CT-confirmed BTAI had a mediastinal abnormality identified on CXR, for a sensitivity of 41% (95% CI: 19-67%). The results from this study suggest that CXR alone is not a reliable screening modality for BTAI. A combination of screening CXR and careful consideration of other factors, such as mechanism of injury, will be required to effectively discriminate between those who should and should not undergo chest CT. Copyright © 2015 Elsevier Ltd. All rights reserved.
1995-11-22
The first cardiac catheterisation of the human heart is attributed to a German surgeon, Dr Werner Forssmann. Against the wishes of his superiors but with the help of his nurse assistant, Gerda Ditzen, Dr Forssmann catheterised himself using a uro- logic catheter via a cutdown in his arm. Having passed the catheter through a vein into the right side of his heart, he calmly walked to the X-ray department for a chest X-ray to confirm the precise position of the catheter within his heart. It is reported that he catheterised himself a total of nine times ( 1 , 2 ).
Development of a computer-aided detection system for lung cancer diagnosis
NASA Astrophysics Data System (ADS)
Suzuki, Hideo; Inaoka, Noriko; Takabatake, Hirotsugu; Mori, Masaki; Sasaoka, Soichi; Natori, Hiroshi; Suzuki, Akira
1992-06-01
This paper describes a modified system for automatic detection of lung nodules by means of chest x ray image processing techniques. The objective of the system is to help radiologists to improve their accuracy in cancer detection. It is known from retrospective studies of chest x- ray images that radiologists fail to detect about 30 percent of lung cancer cases. A computerized method for detecting lung nodules would be very useful for decreasing the proportion of such oversights. Our proposed system consists of five sub-systems, for image input, lung region determination, nodule detection, rule-based false-positive elimination, and statistical false-positive elimination. In an experiment with the modified system, using 30 lung cancer cases and 78 normal control cases, we obtained figures of 73.3 percent and 89.7 percent for the sensitivity and specificity of the system, respectively. The system has been developed to run on the IBM* PS/55* and IBM RISC System/6000* (RS/6000), and we give the processing time for each platform.
High performance x-ray anti-scatter grid
Logan, C.M.
1995-05-23
Disclosed are an x-ray anti-scatter grid for x-ray imaging, particularly for screening mammography, and method for fabricating same, x-rays incident along a direct path pass through a grid composed of a plurality of parallel or crossed openings, microchannels, grooves, or slots etched in a substrate, such as silicon, having the walls of the microchannels or slots coated with a high opacity material, such as gold, while x-rays incident at angels with respect to the slots of the grid, arising from scatter, are blocked. The thickness of the substrate is dependent on the specific application of the grid, whereby a substrate of the grid for mammography would be thinner than one for chest radiology. Instead of coating the walls of the slots, such could be filed with an appropriate liquid, such as mercury. 4 Figs.
Using Gagne's theory to teach chest X-ray interpretation.
Belfield, Jane
2010-03-01
as a Radiologist providing teaching for medical students and junior doctors, I have spent time devising lesson plans. It is vital to know the aims and objectives prior to teaching sessions in order that the students benefit as much as possible. This article describes a lesson plan for interpretation of a chest X-Ray using a theory described by Robert Gagne. Gagne developed a model of instructional design, which provides information and interaction to enhance the learning process. This model is based on nine instructional events used during a teaching session. These are: gaining attention, informing the learner of the objective, stimulating recall of prior material, presenting the stimulus material, providing learning guidance, eliciting the performance, providing feedback, assessing the performance and enhancing retention and transfer. this article uses the nine points described by Gagne and describes a model of how to teach chest X-ray interpretation. Each of Gagne's points is illustrated with a specific example of how this would fit into the Radiology teaching session. Gagne's theory of instructional design can be adapted depending on the subject being taught. It is useful, both for the teacher and the student, to prepare a lesson plan in advance with knowledge of required aims and objectives. Having run teaching sessions which use Gagne's theory, students have given very positive feedback and as a teacher I found the lesson ran more smoothly. Blackwell Publishing Ltd 2010.
... done include: Blood work, possibly including arterial blood gases Chest x-ray Lung function tests A hospital ... 2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing by ADAM ...
Deformable image registration for multimodal lung-cancer staging
NASA Astrophysics Data System (ADS)
Cheirsilp, Ronnarit; Zang, Xiaonan; Bascom, Rebecca; Allen, Thomas W.; Mahraj, Rickhesvar P. M.; Higgins, William E.
2016-03-01
Positron emission tomography (PET) and X-ray computed tomography (CT) serve as major diagnostic imaging modalities in the lung-cancer staging process. Modern scanners provide co-registered whole-body PET/CT studies, collected while the patient breathes freely, and high-resolution chest CT scans, collected under a brief patient breath hold. Unfortunately, no method exists for registering a PET/CT study into the space of a high-resolution chest CT scan. If this could be done, vital diagnostic information offered by the PET/CT study could be brought seamlessly into the procedure plan used during live cancer-staging bronchoscopy. We propose a method for the deformable registration of whole-body PET/CT data into the space of a high-resolution chest CT study. We then demonstrate its potential for procedure planning and subsequent use in multimodal image-guided bronchoscopy.
Optimizing the acquisition geometry for digital breast tomosynthesis using the Defrise phantom
NASA Astrophysics Data System (ADS)
Acciavatti, Raymond J.; Chang, Alice; Woodbridge, Laura; Maidment, Andrew D. A.
2014-03-01
In cone beam computed tomography (CT), it is common practice to use the Defrise phantom for image quality assessment. The phantom consists of a stack of plastic plates with low frequency spacing. Because the x-ray beam may traverse multiple plates, the spacing between plates can appear blurry in the reconstruction, and hence modulation provides a measure of image quality. This study considers the potential merit of using the Defrise phantom in digital breast tomosynthesis (DBT), a modality with a smaller projection range than CT. To this end, a Defrise phantom was constructed and subsequently imaged with a commercial DBT system. It was demonstrated that modulation is dependent on position and orientation in the reconstruction. Modulation is preserved over a broad range of positions along the chest wall if the input frequency is oriented in the tube travel direction. By contrast, modulation is degraded with increasing distance from the chest wall if the input frequency is oriented in the posteroanterior (PA) direction. A theoretical framework was then developed to model these results. Reconstructions were calculated in an acquisition geometry designed to improve modulation. Unlike current geometries in which the x-ray tube motion is restricted to the plane of the chest wall, we consider a geometry with an additional component of tube motion along the PA direction. In simulations, it is shown that the newly proposed geometry improves modulation at positions distal to the chest wall. In conclusion, this study demonstrates that the Defrise phantom is a tool for optimizing DBT systems.
... disorders linked to this condition include leukemia, lymphoma, sarcoidosis, rheumatic fever , Bechet disease, and ulcerative colitis . The ... strep infection Chest x-ray to rule out sarcoidosis or tuberculosis Blood tests to look for infections ...
... Other tests that may be done include: Blood culture Chest x-ray Cryptococcal antigen in CSF or ... the head Gram stain, other special stains, and culture of CSF Treatment Antifungal medicines are used to ...
... tests Chest x-ray EKG (electrocardiogram, or heart tracing) Fluids through a vein (IV) Laxative Naloxone, a ... Toxicology Data Network. Morphine. Toxnet.nlm.nih.gov Web site. toxnet.nlm.nih.gov/cgi-bin/sis/ ...
... x-ray CT scan of the chest Electrocardiogram (ECG or EKG) Echocardiogram These tests may show: Problems ... monitored for at least 24 hours. An electrocardiogram (ECG) will be done continually to check your heart ...
[Usefulness of medical history and physical findings in the diagnosis of pneumonia].
Brander, Patrick; Garin, Nicolas
2011-10-19
Pneumonia is a frequent concern in the ambulatory setting. Diagnosis should be prompt, as delays in the instauration of the treatment are associated with a worse prognosis. However, empiric antibiotic treatment of all patients suspected of having pneumonia is unwarranted, and can affect adversely bacterial ecology. Chest X-ray remains the gold standard, and should always be obtained to confirm the diagnosis, as clinical findings are non-specific. Conversely, some clinical findings can be used to rule out pneumonia with sufficient negative predictive value in a low-prevalence setting. A chest X-ray can be omitted for these patients. We aimed to point which symptoms and signs are useful in assessing the clinical probability of pneumonia, and review clinical rules proposed for this purpose.
N'Goan-Domoua, A M; Konan, A N; Kouame, N; N'Gbesso, R D
2008-01-01
The purpose of this prospective study done from May to July 2007 was to show the interest of systematic chest X-Ray of future bus conductors. The main abnormalities were big heart, parenchymal lesion and pleural effusion.
Radiological progression and its predictive risk factors in silicosis
Lee, H; Phoon, W; Ng, T
2001-01-01
OBJECTIVES—To investigate the risk factors predicting radiological progression in silicosis in a prospective cohort study of patients with silicosis who were previously exposed to silica from granite dust. METHODS—From among a total of 260 patients with silicosis contracted from granite work, 141 with available serial chest x ray films of acceptable quality taken over a period of 2 to 17 (mean 7.5) years, were selected for study. Ninety four (66.7%) had ended exposure 5 or more years perviously (mean 10.1 years, maximum 28 years). Radiological progression was assessed by paired comparison of the initial and most recent radiographs, with two or more steps of increase in profusion of small opacities according to the 12 point scale of the International Labour Organisation (ILO) classification of radiographs of pneumoconiosis, taken from the majority reading by a panel of three independent readers. RESULTS—Overall, 37% of patients with silicosis had radiological evidence of progression. From the initial radiographs, 24 (31.6%) of those with radiological profusion category 1, 15 (37.5%) of those with radiological profusion category 2, and 13 (52%) of those with complicated silicosis (including all seven with category 3 profusion of small opacities) showed radiological progression. As expected, progression was more likely to be found after longer periods of follow up (the interval between the two chest x ray films) with a 20% increased odds of progression for every additional year of follow up. After adjustment for varying intervals of follow up, the probability of radiological progression was found to be significant if large opacities were present in the initial chest x ray film. Progression was also less likely to be found among those who had ended exposure to silica longer ago, although the result was of borderline significance (p=0.07). Tuberculosis was also associated with increased likelihood of progression (borderline significance). CONCLUSIONS—There is a high probability of radiological progression in silicosis after high levels of exposure to granite dust among workers who were followed up for up to 17 years. A significant risk factor is the extent of radiological opacities in the initial chest x ray film. The probability of progression is also likely to be reduced with longer periods after the end of exposure. Keywords: silicosis; radiological progression; granite quarry PMID:11404452
Lung partitioning for x-ray CAD applications
NASA Astrophysics Data System (ADS)
Annangi, Pavan; Raja, Anand
2011-03-01
Partitioning the inside region of lung into homogeneous regions becomes a crucial step in any computer-aided diagnosis applications based on chest X-ray. The ribs, air pockets and clavicle occupy major space inside the lung as seen in the chest x-ray PA image. Segmenting the ribs and clavicle to partition the lung into homogeneous regions forms a crucial step in any CAD application to better classify abnormalities. In this paper we present two separate algorithms to segment ribs and the clavicle bone in a completely automated way. The posterior ribs are segmented based on Phase congruency features and the clavicle is segmented using Mean curvature features followed by Radon transform. Both the algorithms work on the premise that the presentation of each of these anatomical structures inside the left and right lung has a specific orientation range within which they are confined to. The search space for both the algorithms is limited to the region inside the lung, which is obtained by an automated lung segmentation algorithm that was previously developed in our group. Both the algorithms were tested on 100 images of normal and patients affected with Pneumoconiosis.
Liestøl, Knut; Tretli, Steinar; Tverdal, Aage; Maehlen, Jan
2009-04-01
From 1948 to 1975, Norway had a mandatory tuberculosis (TB) screening programme with Pirquet testing, X-ray examinations and BCG vaccination. Electronic data registration in 1963-75 enabled the current study aimed at revealing (i) the relations between socioeconomic factors and tuberculosis infection and (ii) differences in later all-cause mortality according to TB infection status. TB screening data were linked to information from the Norwegian Cause of Death Registry (1975-98) and the National Population and Housing Censuses (1960, 1970 and 1980). Analyses were done for 10 years cohorts born 1910-49, separately for men (approximately 534,000 individuals) and women (608,000), using logistic and Cox regressions. TB infection and X-ray data confirmed the strong regional pattern seen for TB mortality, with the highest rates in the three northernmost counties and higher rates in urban than rural areas. High socioeconomic status relates to lower odds both for TB infection and TB-related chest X-ray findings (odds ratios 0.6-0.7 for highest vs lowest educational groups). Those infected by TB, and especially those with chest X-ray findings, have increased all-cause mortality in at least a 20 years period following determination of tuberculin status (hazard ratios approximately 1.15 and 1.30, respectively, higher for late than early cohorts). TB particularly affected lower socioeconomic strata, but even those in higher strata were at high risk. The differences in all-cause mortality could partly be attributed to socioeconomic factors, but we hypothesize that developing TB infection may also indicate biological frailness.
NASA Astrophysics Data System (ADS)
Bath, Magnus; Hakansson, Markus; Borjesson, Sara; Hoeschen, Christoph; Tischenko, Oleg; Bochud, Francois O.; Verdun, Francis R.; Ullman, Gustaf; Kheddache, Susanne; Tingberg, Anders; Mansson, Lars Gunnar
2005-04-01
The aim of this work was to investigate and quantify the effects of system noise, nodule location, anatomical noise and anatomical background on the detection of lung nodules in different regions of the chest x-ray. Simulated lung nodules of diameter 10 mm but with varying detail contrast were randomly positioned in four different kinds of images: 1) clinical images collected with a 200 speed CR system, 2) images containing only system noise (including quantum noise) at the same level as the clinical images, 3) clinical images with removed anatomical noise, 4) artificial images with similar power spectrum as the clinical images but random phase spectrum. An ROC study was conducted with 5 observers. The detail contrast needed to obtain an Az of 0.80, C0.8, was used as measure of detectability. Five different regions of the chest x-ray were investigated separately. The C0.8 of the system noise images ranged from only 2% (the hilar regions) to 20% (the lateral pulmonary regions) of those of the clinical images. Compared with the original clinical images, the C0.8 was 16% lower for the de-noised clinical images and 71% higher for the random phase images, respectively, averaged over all five regions. In conclusion, regarding the detection of lung nodules with a diameter of 10 mm, the system noise is of minor importance at clinically relevant dose levels. The removal of anatomical noise and other noise sources uncorrelated from image to image leads to somewhat better detection, but the major component disturbing the detection is the overlapping of recognizable structures, which are, however, the main aspect of an x-ray image.
Radiographers' performance in chest X-ray interpretation: the Nigerian experience
Egbe, N O; Akpan, B E
2015-01-01
Objective: To assess the performance of Nigerian radiographers in interpretation of plain chest radiographs and to assess whether age, years since qualification and sector of practice are associated with performance. Methods: A test set of 50 radiographs containing 23 cases with no pathology (normal) and 27 abnormal cases (cardiopulmonary conditions) independently confirmed by 3 radiologists were presented to 51 radiographers in a random order. Readers independently evaluated radiographs for absence or presence of disease and stated the location, radiographic features and diagnosis. Readers self-reported their age, years since qualification and sector of practice. Receiver operating characteristic was used to assess the performance. Mann–Whitney U test was used to assess whether age, years since qualification and sector of practice were associated with performance. Results: Mean location sensitivity was 88.9 [95% confidence interval (CI), 0.787–0.980]. Mean sensitivity and specificity were 76.9 (95% CI, 0.658–0.864) and 79.8 (95% CI, 0.658–0.864), respectively. Age was not associated with performance (p = 0.07). Number of years qualified as radiographer (p = 0.005) and private practice (p = 0.004) were positively associated with performance. Conclusion: Nigerian radiographers can correctly report chest radiographs to a reasonable standard, and performance is associated with number of years since qualification and the sector of practice. Advances in knowledge: There are less than 300 radiologists serving a Nigerian population of about 170 million; therefore, X-ray interpretation by radiographers deserves consideration. Nigerian radiographers have potential to interpret chest X-ray in the clinical setting, and this may significantly improve radiology service delivery in this region. PMID:25966290
... tests Chest x-ray CT (computerized tomography, or advanced imaging) scan EKG (electrocardiogram, or heart tracing) Fluids ... Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; ...
... Iodine is also used during the production of methamphetamine. Note: This list may not be all inclusive. ... breathing machine (ventilator) Blood and urine tests Chest x-ray EKG (electrocardiogram, or heart tracing) Fluids through a ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Zinc toxicity among galvanization workers in the iron and steel industry.
El Safty, Amal; El Mahgoub, Khalid; Helal, Sawsan; Abdel Maksoud, Neveen
2008-10-01
Galvanization is the process of coating steel or cast iron pieces with zinc, allowing complete protection against corrosion. The ultimate goal of this work was to assess the effect of occupational exposure to zinc in the galvanization process on different metals in the human body and to detect the association between zinc exposure and its effect on the respiratory system. This study was conducted in 111 subjects in one of the major companies in the iron and steel industry. There were 61 subjects (workers) who were involved in the galvanization process. Fifty adult men were chosen as a matched reference group from other departments of the company. All workers were interviewed using a special questionnaire on occupational history and chest diseases. Ventilatory functions and chest X rays were assessed in all examined workers. Also, complete blood counts were performed, and serum zinc, iron, copper, calcium, and magnesium levels were tested. This study illustrated the relation between zinc exposure in the galvanization process and high zinc levels among exposed workers, which was associated with a high prevalence rate of metal fume fever (MFF) and low blood copper and calcium levels. There was no statistically significant difference between the exposed and control groups with regards to the magnesium level. No long-term effect of metals exposure was detected on ventilatory functions or chest X rays among the exposed workers.
The application of MDCT in the diagnosis of chest trauma.
Błasińska-Przerwa, Katarzyna; Pacho, Ryszard; Bestry, Iwona
2013-01-01
Traumas are the third most common cause of death worldwide, after cardiovascular diseases and neoplasms, and the main cause of death of patients under 40 years of age. Contemporary image diagnosis of chest trauma uses chest X-ray (CXR), multidetector computed tomography (MDCT), transthoracic and transoesophageal ultrasound (USG), X-ray angiography and magnetic resonance. The aim of the present study was to evaluate MDCT results in the examination of posttraumatic chest injuries and to compare the results of CXR and MDCT in chosen chest traumatic injuries. The sixty patients with chest trauma included in the study were diagnosed at the Department of Radiology of the Institute of Tuberculosis and Lung Diseases between May 2004 and October 2007. MDCT was performed in all patients. Two groups with different types of injury (blunt or penetrating chest trauma) were distinguished. The analysis of injuries in both groups was conducted depending on the mechanism of trauma. The detection of 20 selected injuries at CXR and MDCT was compared. Moreover, the compatibility of MDCT with the results of intraoperative assessment and bronchoscopy was analysed. The influence of MDCT on the treatment modality was also assessed. History of blunt chest trauma was found in 51 patients (group 1) and of penetrating trauma in 9 patients (group 2). The most frequent injuries among group 1 were lung contusion and rib fractures, and among group 2 it was pericardial hematoma. Compared to MDCT, the sensitivity and specificity of CXR were 66.7 and 58%, respectively. Change of treatment modality was observed after MDCT in 83% of patients. The sensitivity and specificity of MDCT in diagnosing tracheobronchial injury, compared to bronchoscopy, were 72.7% and 100%, respectively. Compatibility of MDCT results and intraoperative assessment was observed in 43% of patients, and the main reason for discrepancy was underdiagnosis of diaphragm injury in MDCT. MDCT was a valuable diagnostic method in recognition of chest trauma, characterized by high sensitivity and specificity in the assessment of life-threatening injures and for depicting tracheal and bronchial injuries. The diagnostic value of CXR was low. The compatibility of MCTD and intraoperative assessment was confirmed, with the exception of diaphragm injures and lung laceration. Change of treatment modality was certified after MDCT in 83% of patients.
Provider perceptions concerning use of chest x-ray studies in adult blunt trauma assessments.
Calderon, Georgina; Perez, Daniel; Fortman, Jonathan; Kea, Bory; Rodriguez, Robert M
2012-10-01
Although they infrequently lead to management changing diagnoses, chest x-rays (CXRs) are the most commonly ordered imaging study in blunt trauma evaluation. To determine: 1) the reasons physicians order chest X-ray studies (CXRs) in blunt trauma assessments; 2) what injuries they expect CXRs to reveal; and 3) whether physicians can accurately predict low likelihood of injury on CXR. At a Level I Trauma Center, we asked resident and attending physicians treating adult blunt trauma patients: 1) the primary reason(s) for getting CXRs; 2) what, if any, significant intrathoracic injuries (SITI) they expected CXRs to reveal; and 3) the likelihood of these injuries. An expert panel defined SITI as two or more rib fractures, sternal fracture, pulmonary contusion, pneumothorax, hemothorax, or aortic injury on official CXR readings. There were 484 patient encounters analyzed--65% of participating physicians were residents and 35% were attendings; 16 (3.3%) patients had SITI. The most common reasons for ordering CXRs were: "enough concern for significant injury" (62.9%) and belief that CXR is a "standard part of trauma work-up" (24.8%). Residents were more likely than attendings to cite "standard trauma work-up" (mean difference = 13.5%, p = 0.003). When physicians estimated a < 10% likelihood of SITI on CXR, 2.1% (95% confidence interval [CI] 1.0-4.1%) of patients had SITI; when they predicted a 10-25% likelihood, 5.7% (95% CI 1.2-15.7%) had SITI; and when they predicted a > 25% likelihood, 9.1% (95% CI 3.0-20.0%) had SITI. Physicians order CXRs in blunt trauma patients because they expect to find injuries and believe that CXRs are part of a "standard" work-up. Providers commonly do not expect CXRs to reveal SITI. When providers estimated low likelihood of SITI, the rate of SITI was very low. Published by Elsevier Inc.
... help the delivery team plan treatment. A screening pulse oximeter test usually is done on all newborns right ... and help plan treatment. The tests may include: pulse oximeter monitoring a chest X-ray electrocardiogram (also called ...
... tests Chest x-ray CT (computerized tomography, or advanced imaging) scan EKG (electrocardiogram, or heart tracing) Fluids ... Stanton BF, St. Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; ...
... found in: Household cleaners Metal finishing Swimming pool pH additives Note: This list may not be all ... burns in the esophagus (food pipe) and the stomach (endoscopy) Chest x-ray EKG (electrocardiogram, or heart ...
Ferreira, Eleci Vaz; Gazzana, Marcelo Basso; Sarmento, Muriel Bossle; Guazzelli, Pedro Arends; Hoffmeister, Mariana Costa; Guerra, Vinicius André; Seligman, Renato; Knorst, Marli Maria
2016-01-01
Objective : To determine the prevalence of alternative diagnoses based on chest CT angiography (CTA) in patients with suspected pulmonary thromboembolism (PTE) who tested negative for PTE, as well as whether those alternative diagnoses had been considered prior to the CTA. Methods : This was a cross-sectional, retrospective study involving 191 adult patients undergoing CTA for suspected PTE between September of 2009 and May of 2012. Chest X-rays and CTAs were reviewed to determine whether the findings suggested an alternative diagnosis in the cases not diagnosed as PTE. Data on symptoms, risk factors, comorbidities, length of hospital stay, and mortality were collected. Results : On the basis of the CTA findings, PTE was diagnosed in 47 cases (24.6%). Among the 144 patients not diagnosed with PTE via CTA, the findings were abnormal in 120 (83.3%). Such findings were consistent with an alternative diagnosis that explained the symptoms in 75 patients (39.3%). Among those 75 cases, there were only 39 (20.4%) in which the same alterations had not been previously detected on chest X-rays. The most common alternative diagnosis, made solely on the basis of the CTA findings, was pneumonia (identified in 20 cases). Symptoms, risk factors, comorbidities, and the in-hospital mortality rate did not differ significantly between the patients with and without PTE. However, the median hospital stay was significantly longer in the patients with PTE than in those without (18.0 and 9.5 days, respectively; p = 0.001). Conclusions : Our results indicate that chest CTA is useful in cases of suspected PTE, because it can confirm the diagnosis and reveal findings consistent with an alternative diagnosis in a significant number of patients. PMID:26982039
Mohammadi, S; Bonnet, N; Leprince, P; Charbonneau, E; Berberian, G; Aslani, M; Silvaggio, G; Dorent, R; Pavie, A; Gandjbakhch, I
2007-10-01
We sought to evaluate the screening modality and outcome of lung cancer occurring in heart transplant recipients (HTR) during a 21-year period. We conducted a retrospective review to investigate the incidence, risk factors, screening modality, treatment, and outcomes in HTR with lung cancer. We compared them with a case-matched HTR control group. Out of 829 recipients of heart transplants, 19 cases of bronchogenic carcinoma were found either by routine chest X-ray (n = 10), chest computed tomographic (CT) scanning (n = 4), or by assessment of clinical symptoms (n = 5). The mean time from transplantation to bronchogenic carcinoma diagnosis was 68.8 +/- 42.4 months. A history of smoking was the only risk factor in HTR with bronchogenic carcinoma compared to their case-matched HTR control group ( P < 0.05). Of 18 patients with non-small cell lung cancer (NSCLC), 13 underwent surgery and 5 with advanced cancer underwent chemotherapy and/or radiotherapy. NSCLC was diagnosed by chest X-ray (n = 10), and 6 of these patients died after an average of 43.7 +/- 62.2 months following cancer detection. NSCLC was also diagnosed on the basis of clinical symptoms (n = 4), and 2 of these patients died after a mean follow-up of 9 +/- 4.2 months after cancer diagnosis. All 4 patients in whom cancer was detected by CT scan were alive at an average of 53.5 +/- 36.7 months following cancer detection. The survival rates did not differ between the study and control groups ( P = 0.5). Optimal outcomes of treatment for primary lung cancer after heart transplantation seem to be related to early detection. A high proportion of deaths from NSCLC may be prevented by chest CT scan screening.
NASA Astrophysics Data System (ADS)
Umehara, Kensuke; Ota, Junko; Ishimaru, Naoki; Ohno, Shunsuke; Okamoto, Kentaro; Suzuki, Takanori; Shirai, Naoki; Ishida, Takayuki
2017-02-01
Single image super-resolution (SR) method can generate a high-resolution (HR) image from a low-resolution (LR) image by enhancing image resolution. In medical imaging, HR images are expected to have a potential to provide a more accurate diagnosis with the practical application of HR displays. In recent years, the super-resolution convolutional neural network (SRCNN), which is one of the state-of-the-art deep learning based SR methods, has proposed in computer vision. In this study, we applied and evaluated the SRCNN scheme to improve the image quality of magnified images in chest radiographs. For evaluation, a total of 247 chest X-rays were sampled from the JSRT database. The 247 chest X-rays were divided into 93 training cases with non-nodules and 152 test cases with lung nodules. The SRCNN was trained using the training dataset. With the trained SRCNN, the HR image was reconstructed from the LR one. We compared the image quality of the SRCNN and conventional image interpolation methods, nearest neighbor, bilinear and bicubic interpolations. For quantitative evaluation, we measured two image quality metrics, peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). In the SRCNN scheme, PSNR and SSIM were significantly higher than those of three interpolation methods (p<0.001). Visual assessment confirmed that the SRCNN produced much sharper edge than conventional interpolation methods without any obvious artifacts. These preliminary results indicate that the SRCNN scheme significantly outperforms conventional interpolation algorithms for enhancing image resolution and that the use of the SRCNN can yield substantial improvement of the image quality of magnified images in chest radiographs.
Perlman, David C; Friedmann, Patricia; Horn, Leslie; Nugent, Anne; Schoeb, Veronika; Carey, Jeanne; Salomon, Nadim; Des Jarlais, Don C
2003-09-01
Syringe-exchange programs (SEPs) have proven to be valuable sites to conduct tuberculin skin testing among active injection drug users. Chest x-rays (CXRs) are needed to exclude active tuberculosis prior to initiating treatment for latent tuberculosis infection. Adherence of drug users to referral for off-site chest x-rays has been incomplete. Previous cost modeling demonstrated that a monetary incentive to promote adherence could be justified on the cost basis if it had even a modest effect on adherence. We compared adherence to referral for chest x-rays among injection drug users undergoing syringe exchange-based tuberculosis screening in New York City before and after the implementation of monetary incentives. From 1995 to 1998, there were 119 IDUs referred for CXRs based on tuberculin skin testing at the SEP. From 1999 to 2001, there were 58 IDUs referred for CXRs with a $25 incentive based on adherence. Adherence to CXR referral within 7 days was 46/58 (79%) among individuals who received the monetary incentive versus 17/119 (14%) prior to the implementation of the monetary incentive (P<.0001; odds ratio [OR]=23; 95% confidence interval [CI]=9.5-57). The median time to obtaining a CXR was significantly shorter among those given the incentive than among those referred without the incentive (2 vs. 11 days, P<.0001). In multivariate logistic regression analysis, use of the incentive was highly independently associated with increased adherence (OR=22.9; 95% CI=10-52). Monetary incentives are highly effective in increasing adherence to referral for screening CXRs to exclude active tuberculosis after syringe exchange-based tuberculin skin testing. Prior cost modeling demonstrated that monetary incentives could be justified on the cost basis if they had even a modest effect on adherence. The current data demonstrated that monetary incentives are highly effective at increasing adherence in this setting and therefore are justifiable on a cost basis. When health care interventions for drug users require referral off site, monetary incentives may be particularly valuable in promoting adherence.
NMR Metabolomics in Ionizing Radiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Jian Z.; Xiao, Xiongjie; Hu, Mary Y.
Ionizing radiation is an invisible threat that cannot be seen, touched or smelled and exist either as particles or waves. Particle radiation can take the form of alpha, beta or neutrons, as well as high energy space particle radiation such as high energy iron, carbon and proton radiation, etc. (1) Non-particle radiation includes gamma- and x-rays. Publically, there is a growing concern about the adverse health effects due to ionizing radiation mainly because of the following facts. (a) The X-ray diagnostic images are taken routinely on patients. Even though the overall dosage from a single X-ray image such as amore » chest X-ray scan or a CT scan, also called X-ray computed tomography (X-ray CT), is low, repeated usage can cause serious health consequences, in particular with the possibility of developing cancer (2, 3). (b) Human space exploration has gone beyond moon and is planning to send human to the orbit of Mars by the mid-2030s. And a landing on Mars will follow.« less
Ben-Sira, Liat; Shiran, Shelly I; Pratt, Li-Tal; Precel, Ronit; Ovadia, Dror; Constantini, Shlomi; Roth, Jonathan
2018-05-04
Shunt series (SS) are a common diagnostic tool used to verify shunt integrity. SS include X-ray films of the skull, chest, and abdomen and often are performed either when a shunted patient presents with suspected shunt malfunction or as a screening test to identify shunt disconnections or dislodgment. EOS low-dose biplanar X-rays are associated with significantly reduced radiation doses compared with ordinary X-rays and are used for various indications. This is the first publication on the use of EOS as a SS technique. Over a period of 6 months, EOS were performed at our center for various orthopedic indications, mostly for scoliosis evaluation. Nine children (<20 years of age) had a ventriculoperitoneal shunt and served as the study group. We retrospectively reviewed shunt visibility and integrity in the EOS scans as well as regular SS or plain spinal X-rays. Three patients had bilateral shunts, and 8 had previous X-rays for comparison. In all patients, the shunt integrity was easily demonstrated on the EOS images. Two patients had an identified shunt disconnection confirmed on the EOS images. No shunt-related information was missed on the EOS compared with the other X-ray images. These preliminary results suggest that EOS may be used as an alternative technology to demonstrate shunt integrity instead of regular X-ray SS. Favorable shunt visibility without the need for multiple radiation exposures and image processing (such as stitching) results in a significantly shorter examination time and significant less radiation. Copyright © 2018 Elsevier Inc. All rights reserved.
Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo
2016-07-01
Our aim in this study is to derive an identification limit on a dosimeter for not disturbing a medical image when patients wear a small-type optically stimulated luminescence (OSL) dosimeter on their bodies during X-ray diagnostic imaging. For evaluation of the detection limit based on an analysis of X-ray spectra, we propose a new quantitative identification method. We performed experiments for which we used diagnostic X-ray equipment, a soft-tissue-equivalent phantom (1-20 cm), and a CdTe X-ray spectrometer assuming one pixel of the X-ray imaging detector. Then, with the following two experimental settings, corresponding X-ray spectra were measured with 40-120 kVp and 0.5-1000 mAs at a source-to-detector distance of 100 cm: (1) X-rays penetrating a soft-tissue-equivalent phantom with the OSL dosimeter attached directly on the phantom, and (2) X-rays penetrating only the soft-tissue-equivalent phantom. Next, the energy fluence and errors in the fluence were calculated from the spectra. When the energy fluence with errors concerning these two experimental conditions was estimated to be indistinctive, we defined the condition as the OSL dosimeter not being identified on the X-ray image. Based on our analysis, we determined the identification limit of the dosimeter. We then compared our results with those for the general irradiation conditions used in clinics. We found that the OSL dosimeter could not be identified under the irradiation conditions of abdominal and chest radiography, namely, one can apply the OSL dosimeter to measurement of the exposure dose in the irradiation field of X-rays without disturbing medical images.
Pulmonary ventilation/perfusion scan
... take a ventilation and perfusion scan and then evaluate it with a chest x-ray. All parts ... ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow ...
[Primitive lung abscess: an unusual situation in children].
Bouyahia, O; Jlidi, S; Sammoud, A
2014-12-01
Lung abscess is a localized area of non tuberculosis suppurative necrosis of the parenchyma lung, resulting in formation of a cavity containing purulent material. This pathology is uncommon in childhood. A 3-year-6 month-old boy was admitted with prolonged fever and dyspnea. Chest X-ray showed a non systemized, well limited, thick walled, hydric, and excavated opacity containing an air-fluid level. Chest ultrasound examination showed a collection of 6. 8 cm of diameter in the right pulmonary field with an air-fluid level. Hemoculture showed Staphylococcus aureus. The patient received large spectrum antibiotherapy. Three days after, he presented a septic shock and surgical drainage was indicated. Histological examination confirmed the diagnosis of lung abscess. Any underlying condition such as inoculation site, local cause or immune deficiency, was noted and diagnosis of primary abscess was made. The patient demonstrated complete recovery. He is asymptomatic with normal chest X-ray and pulmonary function after 3 years of evolution. Lung abscess represent a rare cause of prolonged fever in childhood. An underlying condition must be excluded to eliminate secondary abscess. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
A case of severe type of cerebro-costo-mandibular syndrome.
Matić, Aleksandra; Velisavljev-Filipović, Gordana; Lovrenski, Jovan; Gajdobranski, Djordje
2016-01-01
Cerebro-costo-mandibular syndrome (CCMS) is a rare disorder, with only 75 cases described in the literature to date. CCMS is characterized by association of micrognathia and specific multiple rib defects. It is accompanied by mental deficiency in considerable number of cases. Sometimes, there are associated anomalies and problems, such as spine deformities, brain, heart, kidney or ear anomalies, feeding difficulties, delayed psychomotor development, and growth impairment. Depending on severity of deformities and consecutive respiratory insufficiency, in about 35–50% of CCMS cases, death occurs during the first year of life. These cases are referred to as severe types of CCMS. In this paper we present a female infant with severe type of CCMS. Diagnosis was established in the first day of life, based on micrognathia and findings of posterior rib-gap defects on the chest X-ray, accompanied by dyspnea. Progressive severe respiratory insufficiency caused by chest and air-way deformities and exacerbated by episodes of pneumonia, led to respiratory failure and death at the age of 7.5 months. CCMS should be considered in every infant with micrognathia and rib-gap defects on chest X-ray.
2007-10-01
The atrial chamber that is connected to the inferior vena cava is typically the right atrium . The pulmonary veins typically empty into the left ...only “a left chest wall 6 cm scar consistent with surgical history.” The screening chest x-ray is presented below (Fig 1A). Technical limitations...Cardiac MRI images further define the internal cardiac anatomy. On a coronal bright blood MRI image (Fig. 1B; LA = left atrium ; LPA = left
Deep learning with non-medical training used for chest pathology identification
NASA Astrophysics Data System (ADS)
Bar, Yaniv; Diamant, Idit; Wolf, Lior; Greenspan, Hayit
2015-03-01
In this work, we examine the strength of deep learning approaches for pathology detection in chest radiograph data. Convolutional neural networks (CNN) deep architecture classification approaches have gained popularity due to their ability to learn mid and high level image representations. We explore the ability of a CNN to identify different types of pathologies in chest x-ray images. Moreover, since very large training sets are generally not available in the medical domain, we explore the feasibility of using a deep learning approach based on non-medical learning. We tested our algorithm on a dataset of 93 images. We use a CNN that was trained with ImageNet, a well-known large scale nonmedical image database. The best performance was achieved using a combination of features extracted from the CNN and a set of low-level features. We obtained an area under curve (AUC) of 0.93 for Right Pleural Effusion detection, 0.89 for Enlarged heart detection and 0.79 for classification between healthy and abnormal chest x-ray, where all pathologies are combined into one large class. This is a first-of-its-kind experiment that shows that deep learning with large scale non-medical image databases may be sufficient for general medical image recognition tasks.
Diabetic hyperglycemic hyperosmolar syndrome
... glucose Evaluation for possible causes may include: Blood cultures Chest x-ray Electrocardiogram (ECG) Urinalysis Treatment At the start of treatment, the goal is to correct the water loss. This will improve the blood pressure, urine output, ...
... Names Right-sided heart failure; Pulmonary heart disease Patient Instructions Chronic obstructive pulmonary disease - adults - discharge Images Sarcoid, stage IV - chest x-ray Acute vs. chronic conditions Cor pulmonale Respiratory system References Ferri FF. Cor pulmonale. In: Ferri ...
Llauradó, S; Sabaté, A; Ferreres, E; Camprubí, I; Cabrera, A
2014-12-01
Bariatric surgery patients are at high risk of perioperative respiratory adverse events. We hypothesized that the use of sugammadex to reverse neuromuscular blockade could improve postoperative respiratory outcomes. Prospective observational series of consecutive patients scheduled for laparoscopic bariatric surgery in whom neuromuscular blockade was reverted with sugammadex were compared with a historical matched cohort of patients reverted with neostigmines. The necessity of postoperative mechanical ventilation or pathological changes in postoperative chest X-ray were two of the comparisons done. We enrolled 160 patients in each group (Sugammadex - SG and Historical - HG). Two patients (mean, CI 95%), (1.25, 0.34-4.4) in the SG and five patients in the HG (mean, CI 95%), (3.13, 1.34-7.11) required mechanical ventilation immediately after surgery (p=0.38, chi-square test). Significantly less chest X-ray postoperative changes were observed in the SG: 11 patients (6.9%) versus 26 patients (16.3%) in the HG (Odds ratio OR, CI 95%) (0.36, 0.18-0.8). Requirement of mechanical ventilation is not associated to the reversal agent employed. Less pathological postoperative chest X-ray changes were found in the group of patients whose neuromuscular blockade was reverted with sugammadex. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.
Ionizing radiation and breast cancer in men (United States).
Thomas, D B; Rosenblatt, K; Jimenez, L M; McTiernan, A; Stalsberg, H; Stemhagen, A; Thompson, W D; Curnen, M G; Satariano, W; Austin, D F
1994-01-01
The purposes of this study were to determine whether exposure of the vestigial male breast to ionizing radiation is associated with an increase in risk of breast cancer and, if so, to determine whether the apparent effects on risk in men are similar to those reported for women. A population-based case-control study of breast cancer in men was conducted in 10 geographic areas of the United States. Information on possible prior exposure to ionizing radiation, and on other potential risk factors for breast cancer, was obtained from personal interviews of 227 cases and 300 controls who were recruited from October 1983 to September 1986. Evidence from this study that ionizing radiation can cause breast cancer in men includes: a modest trend of increasing risk with frequency of chest X-rays; an increase in risk in men with three or more radiographic examinations, especially if received prior to 1963; and an increase in risk in men who received X-ray treatments to the chest and adjacent body areas. Risk was increased only from 20 to 35 years after initial exposure from either radiographic examinations or X-ray treatments, and declined after three to four decades since last exposure, suggesting a wave of increased risk of finite duration following exposure. The doses of radiation received could not be estimated precisely, but those from diagnostic procedures were likely similar to those received by prepubertal females in prior studies, and the results of those and the present investigation are compatible. The carcinogenic effects of ionizing radiation may be similar in the male and prepubertal female breast.
Cannabis-induced bullous lung disease leading to pneumothorax: Case report and literature review.
Mishra, Rashmi; Patel, Ravi; Khaja, Misbahuddin
2017-05-01
Marijuana use has been increasing in the United States among college students and young adults. Marijuana use has been associated with bullous lung disease which can lead to pneumothorax. There are other recreational drugs like methylphenidate, cocaine and heroin which have been associated with pneumothorax. We present a case of a 30-year-old man with spontaneous pneumothorax associated with marijuana use. The patient had no medical conditions and presented to the emergency room with chest pain. The physical examination revealed decreased breath sound on the right side of the chest. Bed side ultrasound of chest showed stratosphere sign, absent lung sliding; consistent with right-sided pneumothorax. The patient underwent placement of a chest tube. Computed tomography chest scans performed on day two also showed bullous lung disease in the right lung. Serial x-rays of the chest showed re-expansion of the lung. Despite the beneficial effects of Marijuana there are deleterious effects which are emphasized here. This case highlights the need for further studies to establish the relationship between marijuana use and lung diseases in the absence of nicotine use.
Zhou, Bo; Wen, Di; Nye, Katelyn; Gilkeson, Robert C; Eck, Brendan; Jordan, David; Wilson, David L
2017-10-01
We have demonstrated the ability to identify coronary calcium, a reliable biomarker of coronary artery disease, using nongated, 2-shot, dual energy (DE) chest x-ray imaging. Here we will use digital simulations, backed up by measurements, to characterize DE calcium signals and the role of potential confounds such as beam hardening, x-ray scatter, cardiac motion, and pulmonary artery pulsation. For the DE calcium signal, we will consider quantification, as compared to CT calcium score, and visualization. We created stylized and anatomical digital 3D phantoms including heart, lung, coronary calcium, spine, ribs, pulmonary artery, and adipose. We simulated high and low kVp x-ray acquisitions with x-ray spectra, energy dependent attenuation, scatter, ideal detector, and automatic exposure control (AEC). Phantoms allowed us to vary adipose thickness, cardiac motion, etc. We used specialized dual energy coronary calcium (DECC) processing that includes corrections for scatter and beam hardening. Beam hardening over a wide range of adipose thickness (0-30 cm) reduced the change in intensity of a coronary artery calcification (ΔI CAC ) by < 3% in DECC images. Scatter correction errors of ±50% affected the calcium signal (ΔI CAC ) in DECC images ±9%. If a simulated pulmonary artery fills with blood between exposures, it can give rise to a residual signal in DECC images, explaining pulmonary artery visibility in some clinical images. Residual misregistration can be mostly compensated by integrating signals in an enlarged region encompassing registration artifacts. DECC calcium score compared favorably to CT mass and volume scores over a number of phantom perturbations. Simulations indicate that proper DECC processing can faithfully recover coronary calcium signals. Beam hardening, errors in scatter estimation, cardiac motion, calcium residual misregistration etc., are all manageable. Simulations are valuable as we continue to optimize DE coronary calcium image processing and quantitative analysis. © 2017 American Association of Physicists in Medicine.
Wielpütz, Mark O; Heußel, Claus P; Herth, Felix J F; Kauczor, Hans-Ulrich
2014-03-14
Chest X-ray, computed tomography (CT), and magnetic resonance imaging (MRI) each have characteristic advantages and disadvantages that need to be considered in clinical decision-making. This point is discussed in reference to the main types of lung disease that are encountered in practice. A selective literature search was performed in the PubMed and Google Scholar databases. Existing clinical guidelines on the main types of lung disease and studies concerning radiological diagnosis were also con - sidered in this review. There have been no more than a few large-scale, controlled comparative trials of different radiological techniques. Chest X-ray provides general orientation as an initial diagnostic study and is especially useful in the diagnosis of pneumonia, cancer, and chronic obstructive pulmonary disease (COPD). Multi-detector CT affords nearly isotropic spatial resolution at a radiation dose of only 0.2-5 mSv, much lower than before. Its main indications, according to current guidelines, are tumors, acute pulmonary embolism, pulmonary hypertension, pulmonary fibrosis, advanced COPD, and pneumonia in a high-risk patient. MRI is used in the diagnosis of cystic fibrosis, pulmonary embolism, pulmonary hypertension, and bronchial carcinoma. The positive predictive value (PPV) of a chest X-ray in outpatients with pneumonia is only 27% (gold standard, CT); in contrast, an initial, non-randomized trial of MRI in nosocomial pneumonia revealed a PPV of 95%. For the staging of mediastinal lymph nodes in bronchial carcinoma, MRI has a PPV of 88% and positron emission tomography with CT (PET/CT) has a PPV of 79%, while CT alone has a PPV of 41% (gold standard, histology). The choice of radiologicalal technique for the detection, staging, follow-up, and quantification of lung disease should be based on the individual clinical options, so that appropriate treatment can be provided without excessive use of diagnostic testing.
Dilmen, Ugur; Karagol, Belma Saygili; Oguz, Serife Suna
2011-06-01
The aim of this study was to compare and evaluate the efficacy of nebulized 3% hypertonic saline (HS) and recombinant human DNase (rhDNase) treatment for resolution of persistent atelectasis in newborns. Forty newborns (38 preterms) who did not respond to conventional treatment were enrolled to receive either nebulized 3% HS solution (n = 20) or rhDNase (n = 20) between September 2007 and March 2008. Clinical parameters, oxygen saturation and radiological response (chest X-ray scoring) were analyzed before and after administration of 3% HS or rhDNase. The patients of the nebulized 3% HS solution group improved better chest X-ray scores parameters than the patients of the rhDNase group: chest X-ray scores were 5.1 ± 1.9 vs 4.8 ± 1.7 before treatment and 1.0 ± 0.8 vs 2.1 ± 1.4 after treatment (P < 0.001). Resolution time of atelectasis did not differ between the two groups after whole treatment but the percentage of atelectasis resolution after 3 days treatment were 90% (18/20) in the 3% HS group and 70% (14/20) in the rhDNase group. The patients in the 3% HS group improved better also in clinical parameters in comparison to the rhDNase treatment. The difference of oxygen saturation before and after the treatment was 4.6 ± 0.8 in 3% HS group in comparison to 2.6 ± 0.1 in the rhDNase group (P < 0.05). All serum sodium levels were normal in two groups before and after the treatment modalities. This is the first study on the usefulness of nebulized 3% hypertonic saline solution in treating newborns with pulmonary atelectasis. In addition, 3% HS solution was a more effective therapeutic option on the basis of clinical and radiological improvement compared to rhDNase treatment in newborns with pulmonary atelectasis. © 2011 The Authors. Pediatrics International © 2011 Japan Pediatric Society.
Interleukin-2 Receptor and Angiotensin-Converting Enzyme as Markers for Ocular Sarcoidosis
Gundlach, Enken; Hoffmann, Michael Marcus; Prasse, Antje; Heinzelmann, Sonja; Ness, Thomas
2016-01-01
Purpose To study the impact of soluble IL2 receptor (sIL2R), chest x-ray (CxR), and angiotensin-converting enzyme (ACE) as markers for sarcoidosis in uveitis patients. Design Retrospective study. Methods Serum concentrations of sIL2R and ACE were measured in patients with active uveitis. Those with elevated sIL2R and /or ACE values were examined for suspected systemic sarcoidosis. Main Outcome Measure Our main outcome parameters were the specificity and sensitivity of sIL2R, CxR and ACE in screening for ocular sarcoidosis. Results We measured 261 patients with uveitis for sarcoidosis using sIL2R and ACE between January 2008 and November 2011; sarcoidosis was been diagnosed using other tests (e.g. computer tomography, brochoalveolar lavage, biopsy) in 41 of 53 patients with elevated sIL2R values (>639 U/ml) and in one patient with normal sIL2R (582 U/ml). Their mean sIL2R value was 1310 U/ml, extending from 582 to 8659 U/ml. Only 9 patients, however, presented elevated ACE (>82 U/l). Their mean ACE value was 116.4 U/l, ranging from 84.1 to 175.5 U/l. IL2R specificity was 94% with 98% sensitivity. In contrast, ACE had a specificity of 99.5%, but a sensitivity of only 22%; the chest x-ray had a specificity of 100% with 50% sensitivity in detecting sarcoidosis. We observed the entire spectrum of uveitis: sixteen patients suffered from anterior, 8 from intermediate, 16 from posterior, and 2 from panuveitis. Conclusions An elevated level of soluble IL2R suggests sarcoidosis with uveitis more convincingly than ACE, making sIL2R a more effective marker parameter for sarcoidosis than ACE or chest x-ray in uveitis patients. PMID:26799486
[Chest granuloma secondary to methyl methacrylate. Case report].
Martínez-Bistrain, Ricardo; Robles García, Verónica; Cornejo-Morales, Ivonne
2010-01-01
We present the case of a patient with a history of a massive left hemithorax crushing injury in 1985; the exact management of the lesion is unknown. Twenty years later he had a thoracic fistula with a culture that was reported as positive for Enteroccocus faecalis and Staphyloccocus epidermidis. The patient was referred by the chest surgery service with the diagnosis of rib osteomyelitis once complementary imaging tests were performed (plain X-rays, CAT scan and MRI). The patient underwent surgery at our service; a granulomatous reaction secondary to a foreign body (methyl methacrylate and Ethibon) was reported. Chest reconstruction for massive lesions is possible with methyl methacrylate. Imaging studies involve the well-known difficulty to identify this material, given that it may produce signals and densities that are difficult to interpret by specialized physicians.
X-ray tube voltage and image quality in adult and pediatric CT
NASA Astrophysics Data System (ADS)
Huda, W.; Ogden, K. M.; Scalzetti, E. M.; Lavallee, R. L.; Samei, E.
2006-03-01
The purpose of this study was to investigate how tissue x-ray attenuation coefficients, and their uncertainties, vary with x-ray tube voltage in different sized patients. Anthropomorphic phantoms (newborn, 10 year old, adult) were scanned a GE LightSpeed scanner at four x-ray tube voltages. Measurements were made of tissue attenuation in the head, chest and abdomen regions, as well as the corresponding noise values. Tissue signal to noise ratios (SNR) were obtained by dividing the average attenuation coefficient by the corresponding standard deviation. Soft tissue attenuation coefficients, relative to water, showed little variation with patient location or x-ray voltage (< 0.5%), but increasing the x-ray tube voltage from 80 to 140 kV reduced bone x-ray attenuation by ~14%. All tissues except adult bone showed a reduction of noise with increasing x-ray tube voltage (kV); the noise was found to be proportional to kV n and the average value of n for all tissues was -1.19 +/- 0.57. In pediatric patients at a constant x-ray tube voltage, SNR values were approximately independent of the body region, but the adult abdomen soft tissue SNR values were ~40% lower than the adult head. SNR values in the newborn were more than double the corresponding SNR soft tissue values in adults. SNR values for lung and bone were generally lower than those for soft tissues. For soft tissues, increasing the x-ray tube voltage from 80 to 140 kV increased the SNR by an average of ~90%. Data in this paper can be used to help design CT imaging protocols that take into account patient size and diagnostic imaging task.
The health care provider will do a complete physical exam. A nervous system (neurological) exam may show signs of nerve damage. Tests that may be done include: Complete blood count, comprehensive chemistry panel, and urinalysis Chest x-ray C-reactive ...
... clinical research. More Information Related Health Topics Asbestos-Related Lung Diseases Asthma Chest X-Ray COPD Cough Electrocardiogram Heart Failure How the Lungs Work Idiopathic Pulmonary Fibrosis Oxygen Therapy Sarcoidosis Stress Testing NHLBI Resources Taking a Spirometry Test Building ...
... called antiserum to reverse the effect of the venom Medicine to treat symptoms X-rays Tetanus shot, if necessary ... hours. Outcome often depends on how much poisonous venom entered ... A puncture to the person's chest or abdomen may lead to death.
NASA Astrophysics Data System (ADS)
Potuzko, Marci; Shan, Jing; Pearce, Caleb; Lee, Yueh Z.; Lu, Jianping; Zhou, Otto
2015-03-01
Digital chest tomosynthesis (DCT) is a 3D imaging modality which has been shown to approach the diagnostic capability of CT, but uses only one-tenth the radiation dose of CT. One limitation of current commercial DCT is the mechanical motion of the x-ray source which prolongs image acquisition time and introduces motion blurring in images. By using a carbon nanotube (CNT) x-ray source array, we have developed a stationary digital chest tomosynthesis (s- DCT) system which can acquire tomosynthesis images without mechanical motion, thus enhancing the image quality. The low dose and high quality 3D image makes the s-DCT system a viable imaging tool for monitoring cystic fibrosis (CF) patients. The low dose is especially important in pediatric patients who are both more radiosensitive and have a longer lifespan for radiation symptoms to develop. The purpose of this research is to evaluate the feasibility of using s-DCT as a faster, lower dose means for diagnosis and monitoring of CF in pediatric patients. We have created an imaging phantom by injecting a gelatinous mucus substitute into porcine lungs and imaging the lungs from within an anthropomorphic hollow chest phantom in order to mimic the human conditions of a CF patient in the laboratory setting. We have found that our s-DCT images show evidence of mucus plugging in the lungs and provide a clear picture of the airways in the lung, allowing for the possibility of using s- DCT to supplement or replace CT as the imaging modality for CF patients.
Diagnostic accuracy of chest X-rays acquired using a digital camera for low-cost teleradiology.
Szot, Agnieszka; Jacobson, Francine L; Munn, Samson; Jazayeri, Darius; Nardell, Edward; Harrison, David; Drosten, Ralph; Ohno-Machado, Lucila; Smeaton, Laura M; Fraser, Hamish S F
2004-02-01
Store-and-forward telemedicine, using e-mail to send clinical data and digital images, offers a low-cost alternative for physicians in developing countries to obtain second opinions from specialists. To explore the potential usefulness of this technique, 91 chest X-ray images were photographed using a digital camera and a view box. Four independent readers (three radiologists and one pulmonologist) read two types of digital (JPEG and JPEG2000) and original film images and indicated their confidence in the presence of eight features known to be radiological indicators of tuberculosis (TB). The results were compared to a "gold standard" established by two different radiologists, and assessed using receiver operating characteristic (ROC) curve analysis. There was no statistical difference in the overall performance between the readings from the original films and both types of digital images. The size of JPEG2000 images was approximately 120KB, making this technique feasible for slow internet connections. Our preliminary results show the potential usefulness of this technique particularly for tuberculosis and lung disease, but further studies are required to refine its potential.
Wei, Xiaolin; Zou, Guangyan; Chong, Marc Kc; Xu, Lin
2015-09-01
Smoking is an important risk factor of TB. However, no studies have been conducted to identify TB cases from smokers. We assessed the process and initial impact of active case finding among smokers at primary care facilities in a setting with high smoking rates and TB burden. A prospective quasi-experimental study was conducted in para-urban communities in Yunnan China between September 2013 and June 2014. Smokers attending primary care facilities in the intervention group were prescribed chest X-rays if they had diabetes or TB symptoms, or were elders or close contacts of TB patients. Those with X-rays suggestive of TB were referred to TB dispensaries for diagnosis. Passive case finding was practiced in the control group. In the intervention group, we screened 471 smokers with high risks of TB, of whom 73% took chest X-ray examinations. Eight TB cases were diagnosed, reflecting a 1.7% yield rate of all screened smokers. Smokers with diabetes (OR 6.003, 95% CI 1.057-34.075) were more likely to have TB compared with those without. In total, the intervention group reported significantly higher TB notification rate compared with the control group (38.6 vs 22.9 per 100 000, p=0.016). Active case finding among smokers with high risks of TB was feasible and contributed to improved notification rates. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Georgitzikis, Athanasios; Siopi, Dimitra; Doumas, Argyrios; Mitka, Ekaterini; Antoniadis, Antonios
2010-01-01
We report the unusual case of a 29 -year old woman with emotional instability who presented with acute onset chest pain after severe chronic cough. The chest X-ray and the serological tests were normal but the CT scanning, and the bone scanning revealed multiple bilateral rib stress fractures, caused by severe coughing and physical activity and worsened by the patient's emotional instability.
Knowledge Based Components of Expertise in Medical Diagnosis.
1981-09-01
PAPVC. In fact, one variant of PAPVC, "scimitar syndrome ’, de- rives its name from its presentation of such a finding on x-ray (Lucas & Schmidt, 1977...just sort of guessing right now. I would say just Scimitar Syndrome (PAPVC) pri- marily based on the chest x-ray and ah. I’m not really sure whether...think. They don’t say this kid has. got any other kind of vascular disease like Marfans or anything like that that might present with multiple artery
Mehnati, Parinaz; Arash, Mehran; Akhlaghi, Parisa
2018-01-01
The article aims at constructing protective composite shields for breasts in chest computed tomography and investigating the effects of applying these new bismuth composites on dose and image quality. Polyurethane and silicon with 5% of bismuth were fabricated as a protective shield. At first, their efficiency in attenuating the X-ray beam was investigated by calculating the total attenuation coefficients at diagnostic energy range. Then, a physical chest phantom was scanned without and with these shields at tube voltage of 120 kVp, and image parameters together with dose values were studied. The results showed that these two shields have great effects on attenuating the X-ray beam, especially for lower energies (<40 kV), and in average, the attenuation coefficients of bismuth-polyurethane composite are higher in this energy range. The maximum relative differences between the average Hounsfield units (HUs) and noises of images without and with shield for both composites in 13 regions of interest were 4.5% and 15.7%, respectively. Moreover, primary investigation confirmed the ability of both shields (especially polyurethane-bismuth composite) in dose reduction. Comparing these two composites regarding the amount of dose reduction, the changes in HU and noise, and attenuation coefficients in diagnostic energy range, it seems that polyurethane composite is more useful for dose reduction, especially for higher tube voltages. PMID:29628636
Soult, Michael C; Weireter, Leonard J; Britt, Rebecca C; Collins, Jay N; Novosel, Timothy J; Reed, Scott F; Britt, L D
2015-04-01
The objective of this study was to investigate the feasibility of using ultrasound (US) in place of portable chest x-ray (CXR) for the rapid detection of a traumatic pneumothorax (PTX) requiring urgent decompression in the trauma bay. All patients who presented as a trauma alert to a single institution from August 2011 to May 2012 underwent an extended focused assessment with sonography for trauma (FAST). The thoracic cavity was examined using four-view US imaging and were interpreted by a chief resident (Postgraduate Year 4) or attending staff. US results were compared with CXR and chest computed tomography (CT) scans, when obtained. The average age was 37.8 years and 68 per cent of the patients were male. Blunt injury occurred in 87 per cent and penetrating injury in 12 per cent of activations. US was able to predict the absence of PTX on CXR with a sensitivity of 93.8 per cent, specificity of 98 per cent, and a negative predictive value of 99.9 per cent compared with CXR. The only missed PTX seen on CXR was a small, low anterior, loculated PTX that was stable for transport to CT. The use of thoracic US during the FAST can rapidly and safely detect the absence of a clinically significant PTX. US can replace routine CXR obtained in the trauma bay and allow more rapid initiation of definitive imaging studies.
Thoracic irrigation prevents retained hemothorax: a pilot study.
Kugler, Nathan W; Carver, Thomas W; Paul, Jasmeet S
2016-05-15
Upward of 20% of patients undergoing thoracostomy tube (TT) placement develop retained hemothorax (HTx) requiring secondary intervention. The aim of this study was to define the rate of secondary intervention in patients undergoing prophylactic thoracic irrigation. A prospective observational trial of 20 patients who underwent thoracic irrigation at the time of TT placement was conducted. Patients with HTx identified on chest x-ray were included. After standard placement of a 36-French TT, the HTx was evacuated using a sterile suction catheter advanced within the TT. Warmed sterile saline was instilled into the chest through the TT followed by suction catheter evacuation. The TT was connected to the sterile drainage atrium and suction applied. TTs were managed in accordance with our standard division protocol. The population was predominantly (70%) male at median age 35 years, median ISS 13, with 55% suffering penetrating trauma. Thirteen (65%) patients underwent TT placement within 6 h of trauma with the remainder within 24 h. Nineteen patients received the full 1000-mL irrigation. The majority demonstrated significant improvement on postprocedure chest x-ray. The secondary intervention rate was 5%. A single patient required VATS on post-trauma day zero for retained HTx. Median TT duration was 5 d with median length of stay of 7 d. No adverse events related to the pleural lavage were noted. Thoracic irrigation at the time of TT placement for traumatic HTx may decrease the rate of retained HTx. Copyright © 2016 Elsevier Inc. All rights reserved.
Bronchial Leech Infestation in a 15-Year-Old Female.
Moslehi, Mohammad Ashkan; Imanieh, Mohammad Hadi; Adib, Ali
2016-01-01
Foreign body aspiration (FBA) is a common incidence in young children. Leeches are rarely reported as FBA at any age. This study describes a 15-year-old female who presented with hemoptysis, hematemesis, coughs, melena, and anemia seven months prior to admission. Chest X-ray showed a round hyperdensity in the right lower lobe. A chest computed tomography (CT) demonstrated an area of consolidation and surrounding ground glass opacities in the right lower lobe. Hematological investigations revealed anemia. Finally, bronchoscopy was performed and a 5 cm leech was found within the right B 7-8 bronchus and removed by forceps and a Dormia basket.
Bronchial Leech Infestation in a 15-Year-Old Female
Moslehi, Mohammad Ashkan; Imanieh, Mohammad Hadi
2016-01-01
Foreign body aspiration (FBA) is a common incidence in young children. Leeches are rarely reported as FBA at any age. This study describes a 15-year-old female who presented with hemoptysis, hematemesis, coughs, melena, and anemia seven months prior to admission. Chest X-ray showed a round hyperdensity in the right lower lobe. A chest computed tomography (CT) demonstrated an area of consolidation and surrounding ground glass opacities in the right lower lobe. Hematological investigations revealed anemia. Finally, bronchoscopy was performed and a 5 cm leech was found within the right B7-8 bronchus and removed by forceps and a Dormia basket. PMID:27752380
[Residual pleural thickening in tuberculous pleuritis. Associated factors
Ruiz, E; Alegre, J; Alemán, C; Vizcaya, S; Armadans, L; Segura, R M; Andreu, J; Iglesias, D; Fernández de Sevilla, T
2000-10-01
To study the factors related to the development of residual pleural thickening in pleural tuberculosis. We studied 39 patients with tuberculous pleural effusion. A chest X-ray was taken of each patient at the end of treatment. The patients' medical histories, pleural fluid findings and diagnostic chest films were evaluated. Residual pleural thickening was defined as thickening that was visibly greater than 2 mm in the lower side portion of the chest film. Residual pleural thickening developed in 26% of patients and was found mainly in men (RR = 3.86). In no patients with Löwenstein-Jensen cultures positive for Mycobacterium tuberculosis did pleural complications develop. Residual pleural thickening is a common complication of tuberculous pleural effusion. Residual pleural thickening in tuberculous pleurisy occurs more often in men and older patients, and in cases in which pleural liquid culture is negative for M. tuberculosis.
Measurement of lung volumes from supine portable chest radiographs.
Ries, A L; Clausen, J L; Friedman, P J
1979-12-01
Lung volumes in supine nonambulatory patients are physiological parameters often difficult to measure with current techniques (plethysmograph, gas dilution). Existing radiographic methods for measuring lung volumes require standard upright chest radiographs. Accordingly, in 31 normal supine adults, we determined helium-dilution functional residual and total lung capacities and measured planimetric lung field areas (LFA) from corresponding portable anteroposterior and lateral radiographs. Low radiation dose methods, which delivered less than 10% of that from standard portable X-ray technique, were utilized. Correlation between lung volume and radiographic LFA was highly significant (r = 0.96, SEE = 10.6%). Multiple-step regressions using height and chest diameter correction factors reduced variance, but weight and radiographic magnification factors did not. In 17 additional subjects studied for validation, the regression equations accurately predicted radiographic lung volume. Thus, this technique can provide accurate and rapid measurement of lung volume in studies involving supine patients.
[Imaging of pleural diseases: evaluation of imaging methods based on chest radiography].
Poyraz, Necdet; Kalkan, Havva; Ödev, Kemal; Ceran, Sami
2017-03-01
The most commonly employed radiologic method in diagnosis of pleural diseases is conventional chest radiograph. The commonest chest- X-Ray findings are the presence of pleural effusion and thickening. Small pleural effusions are not readily identified on posteroanterior chest radiograph. However, lateral decubitus chest radiograph and chest ultrasonography may show small pleural effusions. These are more efficient methods than posteroanterior chest radiograph in the erect position for demonstrating small amounts of free pleural effusions. Chest ultrasonograph may be able to help in distinguishing the pleural pathologies from parenchymal lesions. On chest radiograph pleural effusions or pleural thickening may obscure the visibility of the underlying disease or parenchymal abnormality. Thus, computed tomography (CT) may provide additional information of determining the extent and severity of pleural disease and may help to differentiate malign pleural lesions from the benign ones. Moreover, CT may provide the differentiation of parenchmal abnormalities from pleural pathologies. CT (coronal and sagittal reformatted images) that also show invasion of chest wall, mediastinum and diaphragm, as well as enlarged hilar or mediastinal lymph nodes. Standart non-invasive imaging techniques may be supplemented with magnetic resonans imaging (MRI).
Limiting chest computed tomography in the evaluation of pediatric thoracic trauma.
Golden, Jamie; Isani, Mubina; Bowling, Jordan; Zagory, Jessica; Goodhue, Catherine J; Burke, Rita V; Upperman, Jeffrey S; Gayer, Christopher P
2016-08-01
Computed tomography (CT) of the chest (chest CT) is overused in blunt pediatric thoracic trauma. Chest CT adds to the diagnosis of thoracic injury but rarely changes patient management. We sought to identify a subset of blunt pediatric trauma patients who would benefit from a screening chest CT based on their admission chest x-ray (CXR) findings. We hypothesize that limiting chest CT to patients with an abnormal mediastinal silhouette identifies intrathoracic vascular injuries not otherwise seen on CXR. All blunt trauma activations that underwent an admission CXR at our Level 1 pediatric trauma center from 2005 to 2013 were retrospectively reviewed. Patients who had a chest CT were evaluated for added diagnoses and change in management after CT. An admission CXR was performed in 1,035 patients. One hundred thirty-nine patients had a CT, and the diagnosis of intra-thoracic injury was added in 42% of patients. Chest CT significantly increased the diagnosis of contusion or atelectasis (30.3% vs 60.4%; p < 0.05), pneumothorax (7.2% vs 18.7%; p < 0.05), and other fractures (4.3% vs 10.8%; p < 0.05) on CXR compared to chest CT. Chest CT changed the management of only 4 patients (2.9%). Two patients underwent further radiologic evaluation that was negative for injury, one had a chest tube placed for an occult pneumothorax before exploratory laparotomy, and one patient had a thoracotomy for repair of aortic injury. Chest CT for select patients with an abnormal mediastinal silhouette on CXR would have decreased CT scans by 80% yet still identified patients with an intrathoracic vascular injury. The use of chest CT should be limited to the identification of intrathoracic vascular injuries in the setting of an abnormal mediastinal silhouette on CXR. Therapeutic study, level IV; diagnostic study, level III.
[Clinical characteristics of lipid aspiration pneumonia in 16 children].
Ge, Lisha; Chen, Sihu; Lin, Miaomiao; Xia, Xiaojiao; Jin, Yimei; He, Shijun
2014-03-01
To investigate clinical characteristics and changes of pulmonary imaging of mineral oil aspiration pneumonia in children. The clinical features, CT findings, and effects of corticosteroid therapy were analyzed in 16 children with mineral oil aspiration pneumonia, who were hospitalized in our hospital from January 2003 to July 2013. All patients with mineral oil aspiration pneumonia had a history of mineral oil administration.Four patients had no clinical manifestations. Ten cases presented fever, and 8 of the 10 patients had fever in 4-8 h after taking mineral oil, and the temperature was between 39-40 °C. There were wheezing in 2 cases, shortness of breath in 6 cases, cyanosis in 1 case, dyspnea in 3 cases, and moaning in 2 cases, chest pain in 1 case, headache and abnormal EEG in 1 case.Six patients had rales in lungs. Peripheral blood white cells increased in 10 cases, and C- reactive protein elevated in 7 patients. Chest CT examination showed abnormal findings in 6 children, and the earliest CT was performed within 2 h after the accident. The rest 10 children got chest X-ray, and 9 of 10 children had abnormal findings. The earliest X-ray was done within 3 h after the accident. And the remaining 1 of 10 children showed no significant changes in the first chest X-ray 2-3 h after the accident until 3 days. All of the patients received corticosteroid and antibiotic treatments, 4 cases underwent bronchoalveolar lavage, 3 patients were given albumin, 6 cases received intravenous immunoglobulin. Three cases delayed in treatment with hormone because of misdiagnosis, and 2 of them had clearly secondary infections. Twelve patients recovered completely from oil aspiration pneumonia after 8 days to 5.5 months. Oil aspiration pneumonia in children occurs in almost all cases after mineral oil aspiration. Pulmonary opacities can be found by chest CT in most patients within 24 hours after mineral oil aspiration. Corticosteroids therapy was effective for patients with exogenous lipid pneumonia, which may inhibit the inflammatory response and possible pulmonary fibrosis.
Patient size and x-ray transmission in body CT.
Ogden, Kent; Huda, Walter; Scalzetti, Ernest M; Roskopf, Marsha L
2004-04-01
Physical characteristics were obtained for 196 patients undergoing chest and abdomen computed tomography (CT) examinations. Computed tomography sections for these patients having no evident pathology were analyzed to determine patient dimensions (AP and lateral), together with the average attenuation coefficient. Patient weights ranged from approximately 3 kg to about 120 kg. For chest CT, the mean Hounsfield unit (HU) fell from about -120 HU for newborns to about -300 HU for adults. For abdominal CT, the mean HU for children and normal-sized adults was about 20 HU, but decreased to below -50 HU for adults weighing more than 100 kg. The effective photon energy and percent energy fluence transmitted through a given patient size and composition was calculated for representative x-ray spectra at 80, 100, 120, and 140 kV tube potentials. A 70-kg adult scanned at 120 kVp transmits 2.6% of the energy fluence for chest and 0.7% for abdomen CT examinations. Reducing the patient size to 10 kg increases transmission by an order of magnitude. For 70 kg patients, effective energies in body CT range from approximately 50 keV at 80 kVp to approximately 67 keV at 140 kVp; increasing patient size from 10 to 120 kg resulted in an increase in effective photon energy of approximately 4 keV. The x-ray transmission data and effective photon energy data can be used to determine CT image noise and image contrast, respectively, and information on patient size and composition can be used to determine patient doses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morais, J.; Carrier, L.; Gariepy, G.
Eosinophilic pneumonia is usually diagnosed based on the findings on chest x-ray, white blood count, and transbronchial biopsy. After reporting a case of Ga-67 lung uptake in eosinophilic pneumonia, its histopathology is discussed and the mechanisms of Ga-67 uptake by inflammatory lesions are reviewed.
... cancers. Your doctor might do a variety of tests to make the diagnosis, including a chest x-ray, CT scan of the lungs, and an examination of tissues for signs of the fungus. Treatment is with antifungal drugs. If you have ABPA, you may also take ...
Sarcoidosis presenting with pleurisy and bilateral pleural effusions.
Johnson, N. M.; Martin, N. D.; McNicol, M. W.
1980-01-01
A patient with acute sarcoidosis is described who presented with pleurisy and bilateral pleural effusions, but no other abnormalities on examination or chest X-ray. This presentation of sarcoidosis is unusual and is discussed. Images Fig. 1 PMID:7433329
Plourde, Miville; Émond, Marcel; Lavoie, André; Guimont, Chantal; Le Sage, Natalie; Chauny, Jean-Marc; Bergeron, Éric; Vanier, Laurent; Moore, Lynne; Allain-Boulé, Nadine; Fratu, Ramona-Florina; Dufresne, Maryline
2013-11-01
The objectives of this study are to determine the prevalence, risk factors, and time to onset of delayed hemothorax and pneumothorax in adults who experienced a minor blunt thoracic trauma. A prospective cohort of 450 consecutive patients was recruited. Eligible patients had to be over 16 years of age, consulted within 72 hours for a trauma, and available for outpatient follow-up at 2, 7, and 14 days posttrauma. The clinical outcome investigated was the presence of delayed pneumothorax or hemothorax on the follow-up chest x-ray. Delayed hemothorax occurred in 11.8% (95% CI 8.8-14.8), and delayed pneumothorax occurred in 0.9% (95% CI 0.2-2.3) of participants. During the 14-day follow-up period, 87.0% of these delayed complications developed in the first week. In the multivariate analysis, the only statistically significant risk factor for delayed complications was the location of fractures on the x-ray of the hemithorax. The adjusted odds ratio was 1.52 (95% CI 0.62-3.73) for the lower ribs (tenth to twelfth rib), 3.11 (95% CI 1.60-6.08) for the midline ribs (sixth to ninth rib), and 5.05 (95% CI 1.80-14.19) for the upper ribs (third to fifth rib) versus patients with no fractures. The presence of at least one rib fracture between the third and ninth rib on the x-ray of the hemithorax is a significant risk factor for delayed hemothorax and pneumothorax.
Kocijancic, Igor
2007-12-01
The aim of this article is to present an overview of our 10 years clinical research work and early clinical experience with small pleural effusions. Small amounts of pleural fluid are severely difficult to identify with imaging methods (chest x-rays and ultrasound). Nevertheless, it may be an important finding, sometimes leading to a definitive diagnosis of pleural carcinomatosis, infection or other pathologic condition. Chest x-rays were used for many years for the diagnosis of small pleural effusions. Lateral decubitus chest radiographs represented a gold standard for imaging of small amounts of plural fluid for more than 80 years. In the last two decades, ultrasonography of pleural space became a leading real-time method for demonstrating small pleural effusions. Furthermore, the advent of sonographic technology actually enables detection of physiologic pleural fluid in some otherwise healthy individuals. In conclusion, new definitions of the key terms in the field of diagnostic imaging of small amounts of pleural fluid seem to be justified. We suggest that the term pleural fluid should determine physiologic pleural space condition while the term pleural effusion should only be used in the cases of pleural involvement or pleural illness.
A Case of Thoracic Endometriosis Syndrome Presenting with Recurrent Catamenial Pneumothorax.
Junejo, Shoaib Z; Singh Lubana, Sandeep; Shina, Sukhdip Singh; Tuli, Sandeep Singh
2018-05-17
BACKGROUND Catamenial pneumothorax (CP) is a spontaneous pneumothorax commonly associated with menstrual periods. Endometrial tissues most commonly involve the pelvic region. However, after the pelvis, the lungs are most frequently involved. Thoracic endometriosis should always be suspected in young women presenting with CP. CASE REPORT A 30-year-old woman with history of endometriosis presented with chief complaint of umbilical pain. A computerized tomography (CT) scan of the abdomen and pelvis was performed, which showed an incidental finding of a large right-sided pneumothorax. Chest X-ray imaging showed 50% pneumothorax. A right-sided chest tube was placed, and after the procedure, a chest X-ray image showed expansion of the right lung. The patient was readmitted for elective resection of an umbilical mass and was again incidentally found to have a recurrent pneumothorax on the right side. She underwent videothoracoscopic pleurodesis with pathology, establishing the diagnosis of catamenial pneumothorax. CONCLUSIONS Thoracic endometriosis resulting in catamenial pneumothorax should be suspected in young women of child-bearing age. Treatment options still under debate include endoscopic resection and videothoracoscopic pleurodesis followed by gonadotrophin-releasing hormone (GnRH) therapy to reduce the rate of postoperative recurrence.
Saldías P, Fernando; Cabrera T, Daniel; de Solminihac L, Ignacio; Hernández A, Pamela; Gederlini G, Alessandra; Díaz F, Alejandro
2007-02-01
Community-acquired pneumonia in adults is a serious health problem in the ambulatory care setting. To define clinical variables associated with the presence of pneumonia in adult patients presenting with fever or respiratory symptoms to the emergency department. Prospective study carried out in the emergency department from the Catholic University Hospital in Santiago, Chile. Three hundred twenty-five patients (53+/-22 years) presenting fever or acute respiratory symptoms were included. After obtaining a clinical history and physical examination, the physician established a tentative diagnosis. Subsequently, a definitive diagnosis was made with the chest X rays. Thirty-four percent of the patients had pneumonia. The clinical diagnosis of pneumonia before X-ray examination was variable among emergency physicians (positive likelihood ratio: 1.5-4.8) and showed only moderate sensitivity (79%) and specificity (66%). The clinical variables significantly associated with the presence of pneumonia were: advanced age (over 75 years), cardiovascular disease, fever, chills, sputum production, orthopnea, altered mental status, cyanosis, dullness on percussion, bronchial breath sounds, crackles, any abnormal vital sign (heart rate>or=100 beats/min, respiratory rate>or=20 breaths/min or temperature>or=38 degrees C) and oxygen saturation below 90% breathing air. Clinical judgment prior to observation of chest X rays had moderate sensitivity and specificity for the diagnosis of pneumonia. There were no individual clinical findings, or combination of findings, that could confirm or exclude the diagnosis of pneumonia for a patient suspected of having this illness.
Group A beta-haemolytic streptococcal acute chest event in a child with sickle cell anaemia.
Suara, R O
2001-06-01
Acute chest syndrome is a major cause of death and hospitalisation in children with sickle cell anaemia. It is often initiated by an infection, particularly pneumonia. Microbial agents previously not associated with acute chest syndrome are becoming increasingly important. Group A beta-haemolytic Streptococcus (GABHS) is thought to be an uncommon cause of pneumonia in children with sickle cell anaemia. We report a 15-year-old African-American girl who presented with an acute chest event characterised by fever, cough, chest pain, shortness of breath, right upper abdominal quadrant pain, jaundice and otitis media. Chest radiograph showed multi-lobar pneumonia with left pleural effusion. Group A beta-haemolytic Streptococcus was isolated from culture of pleural and middle ear fluids. She responded to therapy that included antibiotics, exchange blood transfusion, oxygen, thoracotomy chest tube drainage and decortication. In a child with sickle cell anaemia presenting with fever and an acute chest event, pneumonia should be considered and GABHS recognised as a possible aetiological agent. In addition, a chest X-ray should be obtained and antibiotics against agents causing community-acquired pneumonia instituted.
Tynan, Jennifer R; Duncan, Meghan D; Burbridge, Brent E
2009-10-01
A recent publication from our centre revealed a disturbing finding of a significant incidence of adult fingers seen on the pediatric intensive care unit (PICU) chest radiographs. This is inappropriate occupational exposure to diagnostic radiation. We hypothesized that the incidence of adult fingers on PICU chest radiographs would decline after radiation safety educational seminars were given to the medical radiation technologists and PICU staff. The present study's objectives were addressed by using a pretest-posttest design. Two cross-sectional PICU chest radiograph samples, taken before and after the administration of radiation safety education for our medical radiation technologists and PICU staff, were compared by using a chi2 test. There was a 61.2% and 76.9% reduction in extraneous adult fingers, directly exposed to the x-ray beam and those seen in the coned regions of the film, respectively, on PICU chest radiographs (66.7% reduction overall). This reduction was statistically significant (chi2 = 20.613, P < .001). Limiting unnecessary occupational radiation exposure is a critical issue in radiology. There was a statistically and clinically significant association between radiation safety education and the decreased number of adult fingers seen on PICU chest radiographs. This study provides preliminary evidence in favour of the benefit of radiation safety seminars.
Yoo, Je-Hyun; Kim, Ki-Tae; Kim, Tae-Young; Hwang, Ji-Hyo; Chang, Jun-Dong
2017-02-01
Displaced femoral neck fracture in elderly patients has been treated with hemiarthroplasty as the treatment of choice. Fever following HA is common in these elderly patients. The aim of this study was to determine which post-HA fever workup could be beneficial in this group of patients. A total of 272 consecutive patients aged ≥70 years undergoing HA for displaced femoral neck fracture were retrospectively investigated. Postoperative fever (POF) was defined as any recorded body temperature ≥38°C in the early postoperative period. POF in each patient was characterized by the maximum temperature, the day of the first fever, and frequency of fever, stratified as either single or multiple fever spikes. Medical records were reviewed to identify positive fever workups and febrile complications. Of 272 patients, 135 (49.6%) developed POF. A total of 428 routine diagnostic tests were performed in all patients with POF, of which only 57 tests (13.3%) were positive. Urinalysis showed the highest positive rate (21.9%), followed by urine culture (14.3%), chest x-ray (12.6%), and blood culture (1.1%). The most common febrile complication was pneumonia (12.6%), followed by urinary tract infection (8.1%). On multivariate logistic regression for positive workups, only fever after postoperative day (POD) 2 was a risk factor for positive chest x-ray (OR 3.86, p=0.016) and urine culture (OR 5.04, p=0.019). Moreover, fever after POD 2 (OR 6.93, p<0.0001) and multiple fever spikes (OR 2.92, p=0.026) were independent predictors of infectious febrile complications. Routine workup for POF following hemiarthroplasty in elderly patients with displaced femoral neck fracture is not warranted. However, for fever after POD 2 and multiple fever spikes, chest x-ray and urinalysis would be necessary to rule out the two most common febrile complications such as pneumonia and urinary tract infection. Copyright © 2016 Elsevier Ltd. All rights reserved.
The impact of gas exchange measurement during exercise in pulmonary sarcoidosis.
Kollert, Florian; Geck, Barbara; Suchy, Rolf; Jörres, Rudolf A; Arzt, Michael; Heidinger, Dominic; Hamer, Okka W; Prasse, Antje; Müller-Quernheim, Joachim; Pfeifer, Michael; Budweiser, Stephan
2011-01-01
Pulmonary sarcoidosis shows a remarkable heterogeneity of phenotypes ranging from bihilar lymphadenopathy to progressive fibrosis. Individual disease assessment is demanding and requires sensible, practical measures. We tested whether gas exchange measurements during exercise reflects disease activity and clinical course in sarcoidosis. In 149 patients with proven pulmonary sarcoidosis the alveolar-arterial oxygen pressure gradient (P(A-a)O(2)) during exercise was assessed and compared with chest X-ray typing, pulmonary function, single breath-diffusing capacity for carbon monoxide (DL(CO)), serological markers, cell composition of bronchoalveolar lavage fluid (BALF) and clinical course. Patients were categorized according to thresholds of P(A-a)O(2) during exercise. Chest X-ray typing, pulmonary function, DL(CO) and the need for immunosuppressive treatment differed between the disease categories based on P(A-a)O(2) during exercise (p < 0.0001 each). Patients with an impairment of gas exchange during exercise also showed elevated levels of neopterin (p = 0.002) and higher percentages of neutrophils (p = 0.013) and eosinophils (p < 0.0001) in BALF. Multivariate regression analysis showed that forced vital capacity (FVC) (p = 0.009) and P(A-a)O(2) during exercise (p < 0.0001) were independently associated with a prolonged need for immunosuppressive treatment (>1 year), but not DL(CO). About 50% (n = 75) of the study population showed a normal spirometry. Even in this subgroup 23% had an impaired gas exchange during exercise, which correlated with chest X-ray types (p < 0.0001) and the need for immunosuppressive treatment (p < 0.005). Impaired gas exchange during exercise reflects disease activity and its extent and is associated with a prolonged need for immunosuppressive treatment during follow-up in patients with pulmonary sarcoidosis. Copyright © 2010 Elsevier Ltd. All rights reserved.
Becker, A S; Blüthgen, C; Phi van, V D; Sekaggya-Wiltshire, C; Castelnuovo, B; Kambugu, A; Fehr, J; Frauenfelder, T
2018-03-01
To evaluate the feasibility of Deep Learning-based detection and classification of pathological patterns in a set of digital photographs of chest X-ray (CXR) images of tuberculosis (TB) patients. In this prospective, observational study, patients with previously diagnosed TB were enrolled. Photographs of their CXRs were taken using a consumer-grade digital still camera. The images were stratified by pathological patterns into classes: cavity, consolidation, effusion, interstitial changes, miliary pattern or normal examination. Image analysis was performed with commercially available Deep Learning software in two steps. Pathological areas were first localised; detected areas were then classified. Detection was assessed using receiver operating characteristics (ROC) analysis, and classification using a confusion matrix. The study cohort was 138 patients with human immunodeficiency virus (HIV) and TB co-infection (median age 34 years, IQR 28-40); 54 patients were female. Localisation of pathological areas was excellent (area under the ROC curve 0.82). The software could perfectly distinguish pleural effusions from intraparenchymal changes. The most frequent misclassifications were consolidations as cavitations, and miliary patterns as interstitial patterns (and vice versa). Deep Learning analysis of CXR photographs is a promising tool. Further efforts are needed to build larger, high-quality data sets to achieve better diagnostic performance.
Lumbar Spine X-Ray as a Standard Investigation for all Low back Pain in Ghana: Is It Evidence Based?
Tannor, Abena Y
2017-03-01
Low back pain (LBP) has a prevalence of 84% in Africa. The commonest form of imaging is plain lumbar spine x-ray. It gives a radiation dose equivalent to 65 times a chest x-ray dose and sends one of the highest doses to the human reproductive organs. The commonest cause of LBP in Africa is degenerative disease. X-ray findings do not change mode of treatment yet most physicians still routinely request for x-rays. This is a systematic review of databases including The Cochrane, CINAHL plus, AMED, and MEDLINE. Key evidence was clinical guidelines on x-ray use for low back pain. Key search terms included low back pain, x-rays, guidelines, Ghana. Four clinical guidelines on LBP emerged from two Systematic Reviews rated excellent and four good Randomized Controlled Trials: The European guidelines for acute and sub-acute non-specific Low Back Pain, The American College of Physicians and the American Pain Society guideline for diagnostic imaging for Low Back Pain, The NICE guidelines for persistent non-specific Low Back Pain and the Ghana Standard Treatment Guidelines (GSTG). All the guidelines agree that a good history and clinical examination for all LBP patients helps in diagnosing. Only GSTG recommends routine plain spinal x-rays. There is strong evidence indicating very little benefit from routine lumbar spine x-rays for all LBP. The GSTG needs to be revised considering the increased risks of radiation exposure and the x-ray costs. None declared.
National Lung Screening Trial: Questions and Answers
Learn the results of the National Lung Screening Trial (NLST), which compared two ways of detecting lung cancer: low-dose helical (spiral) computed tomography and standard chest X-ray, for their effects on lung cancer death rates in a high-risk population.
Pulmonary hydatid embolization. Report on 2 operated cases and review of published reports.
Palant, A; Deutsch, V; Kishon, Y; Lieberman, Y; Yahini, J H; Neufeld, H N
1976-01-01
Two patients with pulmonary hydatid embolization are described and commented upon in the light of 43 similar published cases. The diagnosis was strongly suspected from the medical history and the chest x-ray films and supported by angiocardiography. The angiocardiographic features of this condition have not been described previously in detail. They include amputation and filling defects of pulmonary artery branches, which are typically located proximal to a rounded tumour-like opacity seen on the plain x-ray film. Both patients underwent successful embolectomy. Images PMID:973883
Practical applications of digital tomosynthesis of the chest.
Galea, A; Durran, A; Adlan, T; Gay, D; Riordan, R; Dubbins, P; Williams, M P
2014-04-01
Digital tomosynthesis is a radiographic technique that generates a number of coronal raw images of a patient from a single pass of the x-ray tube. Tomosynthesis provides some of the tomographic benefits of computed tomography (CT), but at a much lower dose of radiation and cost when compared to CT. This review illustrates the range of practical applications of digital tomosynthesis of the chest. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imbriano, L.J.; Mandel, P.R.; Cordaro, A.F.
The value of Ga-67 scanning to detect acute infectious lung disease has been described. We present a patient who apparently improved both clinically and radiographically after acute Legionnaires' pneumonia. Five months later a relapse developed. During his relapse the pulmonary uptake of Ga-67 and the appearance of chest x-rays were disparate. We suggest that pulmonary Ga-67 uptake may be a more sensitive indicator of the resolution of pneumonia than is chest radiography. Therapeutic success may be assumed when pulmonary Ga-67 uptake is absent.
Hyperventilation and aerophagia: a negative report.
Folgering, H; Sistermans, H
1986-03-01
Aerophagia is described as a frequent symptom in the hyperventilation syndrome. However, this has never been substantiated. In this study the extent of air swallowing was estimated from the size of the gastric air-bubble on the chest X-ray, in a group of 62 hyperventilators and in a group of 62 normals. No differences were found between the mean amounts of gastric air in the two groups. Women in both groups seemed to swallow more air than men. The amount of air was not related to the time of the day (meals). In 15 hyperventilators the subjective complaints of upper abdominal discomfort and of chest pain were quantified: no correlation was found with the amount of gastric air.
Guirao-Arrabal, Emilio; Torre-Cisneros, Julián
2018-05-24
We have read with great interest the article entitled 'Tuberculosis (TB) after liver transplantation in a large center in New York City: QuantiFERON ® -TB Gold-based pre-transplant screening performance and active TB post transplant' by Hand et al. 1 The authors' results are in accordance with our previously published data in lung transplantation, in which we reported that radiologic findings in pretransplant chest computed tomography (CT) compatible with residual TB are an independent risk factor for post-transplant TB. 2 This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
A discrimination method for the detection of pneumonia using chest radiograph.
Noor, Norliza Mohd; Rijal, Omar Mohd; Yunus, Ashari; Abu-Bakar, S A R
2010-03-01
This paper presents a statistical method for the detection of lobar pneumonia when using digitized chest X-ray films. Each region of interest was represented by a vector of wavelet texture measures which is then multiplied by the orthogonal matrix Q(2). The first two elements of the transformed vectors were shown to have a bivariate normal distribution. Misclassification probabilities were estimated using probability ellipsoids and discriminant functions. The result of this study recommends the detection of pneumonia by constructing probability ellipsoids or discriminant function using maximum energy and maximum column sum energy texture measures where misclassification probabilities were less than 0.15. 2009 Elsevier Ltd. All rights reserved.
Ohkado, Akihiro; Mercader, Marvin; Date, Takuji
2017-01-01
It is of critical importance to improve and maintain the quality of chest radiography (CXR) to avoid faulty diagnosis of respiratory diseases. The study aims to determine the effectiveness of a training program in improving the quality of CXR among radiological technologists (RTs) in Laos. This was a cross-sectional study, conducted through on-site investigation of X-ray facilities, assessment of CXR films in Laos, both before and after a training course in November 2013. Each RT prospectively selected 6 recent CXR films, taken both before and within approximately 6 months of attending the training course. Consequently, 12 CXR films per RT were supposed to be collected for assessment. The quality of the CXR films was assessed using the "Assessment Sheet for Imaging Quality of Chest Radiography." Nineteen RTs from 19 facilities at 16 provinces in Laos participated in the training course. Among them, 17 RTs submitted the required set of CXR films (total: 204 films). A wide range of X-ray machine settings had been used as tube voltage ranged from 40 to 130 kV. The assessment of the CXR films indicated that the training was effective in improving the CXR quality regarding contrast (P = 0.005), sharpness (P = 0.004), and the total score on the 6 assessment factors (P = 0.009). The significant improvement in the total score on the 6 assessment factors, in contrast, and in sharpness, strongly suggests that the training course had a positive impact on the quality of CXR among a sample trainees of RTs in Laos.
Enhancement of chest radiographs using eigenimage processing
NASA Astrophysics Data System (ADS)
Bones, Philip J.; Butler, Anthony P. H.; Hurrell, Michael
2006-08-01
Frontal chest radiographs ("chest X-rays") are routinely used by medical personnel to assess patients for a wide range of suspected disorders. Often large numbers of images need to be analyzed. Furthermore, at times the images need to analyzed ("reported") when no radiological expert is available. A system which enhances the images in such a way that abnormalities are more obvious is likely to reduce the chance that an abnormality goes unnoticed. The authors previously reported the use of principal components analysis to derive a basis set of eigenimages from a training set made up of images from normal subjects. The work is here extended to investigate how best to emphasize the abnormalities in chest radiographs. Results are also reported for various forms of image normalizing transformations used in performing the eigenimage processing.
NASA Astrophysics Data System (ADS)
Makri, T.; Yakoumakis, E.; Papadopoulou, D.; Gialousis, G.; Theodoropoulos, V.; Sandilos, P.; Georgiou, E.
2006-10-01
Seeking to assess the radiation risk associated with radiological examinations in neonatal intensive care units, thermo-luminescence dosimetry was used for the measurement of entrance surface dose (ESD) in 44 AP chest and 28 AP combined chest-abdominal exposures of a sample of 60 neonates. The mean values of ESD were found to be equal to 44 ± 16 µGy and 43 ± 19 µGy, respectively. The MCNP-4C2 code with a mathematical phantom simulating a neonate and appropriate x-ray energy spectra were employed for the simulation of the AP chest and AP combined chest-abdominal exposures. Equivalent organ dose per unit ESD and energy imparted per unit ESD calculations are presented in tabular form. Combined with ESD measurements, these calculations yield an effective dose of 10.2 ± 3.7 µSv, regardless of sex, and an imparted energy of 18.5 ± 6.7 µJ for the chest radiograph. The corresponding results for the combined chest-abdominal examination are 14.7 ± 7.6 µSv (males)/17.2 ± 7.6 µSv (females) and 29.7 ± 13.2 µJ. The calculated total risk per radiograph was low, ranging between 1.7 and 2.9 per million neonates, per film, and being slightly higher for females. Results of this study are in good agreement with previous studies, especially in view of the diversity met in the calculation methods.
Rodríguez Pérez, Sunay; Marshall, Nicholas William; Struelens, Lara; Bosmans, Hilde
2018-01-01
This work concerns the validation of the Kyoto-Kagaku thorax anthropomorphic phantom Lungman for use in chest radiography optimization. The equivalence in terms of polymethyl methacrylate (PMMA) was established for the lung and mediastinum regions of the phantom. Patient chest examination data acquired under automatic exposure control were collated over a 2-year period for a standard x-ray room. Parameters surveyed included exposure index, air kerma area product, and exposure time, which were compared with Lungman values. Finally, a voxel model was developed by segmenting computed tomography images of the phantom and implemented in PENELOPE/penEasy Monte Carlo code to compare phantom tissue-equivalent materials with materials from ICRP Publication 89 in terms of organ dose. PMMA equivalence varied depending on tube voltage, from 9.5 to 10.0 cm and from 13.5 to 13.7 cm, for the lungs and mediastinum regions, respectively. For the survey, close agreement was found between the phantom and the patients' median values (deviations lay between 8% and 14%). Differences in lung doses, an important organ for optimization in chest radiography, were below 13% when comparing the use of phantom tissue-equivalent materials versus ICRP materials. The study confirms the value of the Lungman for chest optimization studies.
The Role of Echocardiography in Coronary Artery Disease and Acute Myocardial Infarction
Esmaeilzadeh, Maryam; Parsaee, Mozhgan; Maleki, Majid
2013-01-01
Echocardiography is a non-invasive diagnostic technique which provides information regarding cardiac function and hemodynamics. It is the most frequently used cardiovascular diagnostic test after electrocardiography and chest X-ray. However, in a patient with acute chest pain, Transthoracic Echocardiography is essential both for diagnosing acute coronary syndrome, zeroing on the evaluation of ventricular function and the presence of regional wall motion abnormalities, and for ruling out other etiologies of acute chest pain or dyspnea, including aortic dissection and pericardial effusion. Echocardiography is a versatile imaging modality for the management of patients with chest pain and assessment of left ventricular systolic function, diastolic function, and even myocardial and coronary perfusion and is, therefore, useful in the diagnosis and triage of patients with acute chest pain or dyspnea. This review has focused on the current applications of echocardiography in patients with coronary artery disease and myocardial infarction. PMID:23646042
Tension bulla: a cause of reversible pulmonary hypertension.
Waxman, Michael J; Waxman, Jacob D; Forman, John M
2015-01-01
A tension pneumothorax represents a medical emergency warranting urgent diagnosis and treatment. A rapidly expanding bulla may resemble the same clinical presentation but requires an entirely different treatment. A 53-year-old woman presented with increasing shortness of breath and her physical examination and chest x-ray were interpreted as showing a tension pneumothorax. A chest tube was placed which did not resolve the process. Placement of a second chest tube was likewise unsuccessful. A chest CT was then performed and was interpreted as showing an unresolved tension pneumothorax, despite seemingly adequate placement of the 2 chest tubes. Further review of the CT showed the border of a giant bulla and a tentative diagnosis was made of a rapidly expanding bulla with tension physiology. Echocardiogram revealed significant pulmonary hypertension. The bulla was surgically excised, the patient had marked improvement in her clinical symptoms and signs, and echocardiographic follow-up showed complete resolution of the pulmonary hypertension.
Zeinali-Rafsanjani, B; Mosleh-Shirazi, M A; Faghihi, R; Karbasi, S; Mosalaei, A
2015-01-01
To accurately recompute dose distributions in chest-wall radiotherapy with 120 kVp kilovoltage X-rays, an MCNP4C Monte Carlo model is presented using a fast method that obviates the need to fully model the tube components. To validate the model, half-value layer (HVL), percentage depth doses (PDDs) and beam profiles were measured. Dose measurements were performed for a more complex situation using thermoluminescence dosimeters (TLDs) placed within a Rando phantom. The measured and computed first and second HVLs were 3.8, 10.3 mm Al and 3.8, 10.6 mm Al, respectively. The differences between measured and calculated PDDs and beam profiles in water were within 2 mm/2% for all data points. In the Rando phantom, differences for majority of data points were within 2%. The proposed model offered an approximately 9500-fold reduced run time compared to the conventional full simulation. The acceptable agreement, based on international criteria, between the simulations and the measurements validates the accuracy of the model for its use in treatment planning and radiobiological modeling studies of superficial therapies including chest-wall irradiation using kilovoltage beam.
[Factors predicting mortality during an outbreak of Legionnaire's disease in the north of France].
Prevotat, A; Bure, M; Bergoin, C; Tavernier, J-Y; Van Grunderbeeck, N; Yazdanpanah, Y; Lamblin, C
2008-03-01
Between November 2003 and January 2004 in the North of France a large outbreak of legionnaire's disease affected 85 patients. The clinical, biological and radiological characteristics of the patients were investigated to determine factors associated with mortality. Two populations were defined and compared: patients who died within 28 days and those who survived. Eighty-five patients were included in this study. The median age was 75 years. The median fever was 39.3 +/- 0.1 degrees. Fifteen patients (17.6%) had at least 3 underlying co-morbidities. Cough, dyspnoea, confusion and diarrhoea were found in respectively 46, 68, 47, and 15% of the patients. The median of urea was 0.7 +/- 0.05 g/L, creatinine 16 +/- 1.5 mg/L, CRP 332 +/- 15 mg/L. On the chest X-ray, lung infiltrates were present in 64% and multilobar in 40%. The overall mortality rate was 21%. In univariate analysis, diabetes mellitus, dyspnoea, urea>0.90 g/l and CRP>350 mg/l were predictive factors of mortality. In multivariate analysis, diabetes mellitus, urea>0.90 g/l, and bilateral infiltrates on chest X ray were retained as independent risk factors for death.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, S; Ali, S; Harper, K
Purpose: To correct in-vivo metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters dependence on X-ray energy, dose and dose rate, and temperature in order to measure doses or exposures on several anatomic points of interest undergoing some routine radiographs. Methods: A mobile MOSFET system (BEST Medical) was carefully calibrated with X-ray at kVp of 70, 80, 100, 120, and 138 kVp, phantom temperatures at 0, 21, and 43 oC, and exposure range from 0.01 to 10 R confirmed with Raysafe and RadCal dosimeters. The MOSFETS were placed on the midline bladder or uterus, left pelvic iliac artery, left abdominal above iliac crest, abdominalmore » midline anterior at inferior margin of stomach, and left pectoral of a large and a small body-size cadavers undergoing AP/PA chest and lumber spine radiographs using manual and automatic exposure control (AEC) with and without lead shielding. MOSTFETs and TLD chips were also placed on the stomach, sigmoid, pubic symphysis, left and right pelvic walls of another cadaver for AP pelvic manual or AEC radiography prior to and after a left hip metal implant. Results: Individual MOSFET detectors had various low-dose limits in ranged from 0.03 to 0.08 R, nonlinear response to X-ray energy, and significant temperature effect of 15%. By accumulating 10 manual exposures and 20 AEC exposures, we achieved dose measured accuracy of 6%. There were up to 8 fold increases for AEC exposure of spine and chest X-ray procedure from no shielding to with shielding. For pelvic radiography, exposure to public symphysis was the highest even higher than that of the skin. After hip implant, AEC pelvic radiograph increase exposure by 30 to 200% consistent with results of TLDs. Conclusion: Dependence of energy, temperature and dose limit were accurately corrected. We have found significant exposure for those clinical pr°ocedures and the study provided evidences for developing new clinical procedures.« less
Comparison of dual and single exposure techniques in dual-energy chest radiography.
Ho, J T; Kruger, R A; Sorenson, J A
1989-01-01
Conventional chest radiography is the most effective tool for lung cancer detection and diagnosis; nevertheless, a high percentage of lung cancer tumors are missed because of the overlap of lung nodule image contrast with bone image contrast in a chest radiograph. Two different energy subtraction strategies, dual exposure and single exposure techniques, were studied for decomposing a radiograph into bone-free and soft tissue-free images to address this problem. For comparing the efficiency of these two techniques in lung nodule detection, the performances of the techniques were evaluated on the basis of residual tissue contrast, energy separation, and signal-to-noise ratio. The evaluation was based on both computer simulation and experimental verification. The dual exposure technique was found to be better than the single exposure technique because of its higher signal-to-noise ratio and greater residual tissue contrast. However, x-ray tube loading and patient motion are problems.
Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R
2013-07-01
The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.
Task-Driven Dictionary Learning Based on Mutual Information for Medical Image Classification.
Diamant, Idit; Klang, Eyal; Amitai, Michal; Konen, Eli; Goldberger, Jacob; Greenspan, Hayit
2017-06-01
We present a novel variant of the bag-of-visual-words (BoVW) method for automated medical image classification. Our approach improves the BoVW model by learning a task-driven dictionary of the most relevant visual words per task using a mutual information-based criterion. Additionally, we generate relevance maps to visualize and localize the decision of the automatic classification algorithm. These maps demonstrate how the algorithm works and show the spatial layout of the most relevant words. We applied our algorithm to three different tasks: chest x-ray pathology identification (of four pathologies: cardiomegaly, enlarged mediastinum, right consolidation, and left consolidation), liver lesion classification into four categories in computed tomography (CT) images and benign/malignant clusters of microcalcifications (MCs) classification in breast mammograms. Validation was conducted on three datasets: 443 chest x-rays, 118 portal phase CT images of liver lesions, and 260 mammography MCs. The proposed method improves the classical BoVW method for all tested applications. For chest x-ray, area under curve of 0.876 was obtained for enlarged mediastinum identification compared to 0.855 using classical BoVW (with p-value 0.01). For MC classification, a significant improvement of 4% was achieved using our new approach (with p-value = 0.03). For liver lesion classification, an improvement of 6% in sensitivity and 2% in specificity were obtained (with p-value 0.001). We demonstrated that classification based on informative selected set of words results in significant improvement. Our new BoVW approach shows promising results in clinically important domains. Additionally, it can discover relevant parts of images for the task at hand without explicit annotations for training data. This can provide computer-aided support for medical experts in challenging image analysis tasks.
Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno
2013-01-01
OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough. METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons. RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6%) of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6%) of the patients, whereas the treatment was ineffective in 1 (8.4%). We observed no complications related to barium swallow, such as contrast aspiration. CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies. PMID:24473762
Laucyte-Cibulskiene, Agne; Petraviciute, Modesta; Gudynaite, Migle; Gumbys, Liutauras; Valanciene, Dileta; Galiauskiene, Kristina; Ryliskyte, Ligita; Rimsevicius, Laurynas; Miglinas, Marius; Strupas, Kestutis
2018-04-01
Vascular calcification is one of the risk factors for arterial stiffness in patients with chronic kidney disease. We hypothesized that a mismatch between elastic and muscular arteries, represented as pulse wave velocity (PWV) ratio, could depict the extent of vascular calcification in end-stage renal disease. We also aimed to compare the predictive PWV ratio value to other factors possibly related to vascular calcification in dialysis population. In this cross-sectional study, in 60 chronic dialysis patients without previous cerebrovascular events, cardiovascular disease and events or clinically evident peripheral artery disease (ankle-brachial index >0.9), carotid-femoral and carotid-radial PWV as well as central hemodynamic parameters were measured by applanation tonometry (SphygmoCor). The PWV ratio using carotid-femoral PWV divided by carotid-radial PWV was calculated. Each patient underwent blood tests and chest X-ray for aortic arch calcification scoring. Two experienced radiologists blinded to patient's medical data evaluated chest X-rays (Cohen's kappa coefficient 0.76) and calculated how many sectors were calcified (Ogawa et al. in Hemodial Int 13:301-306, 2009). Differently scored chest X-rays were repeatedly reviewed and a consensus was reached. The study population consisted of 31 (51.7%) males and 29 (48.3%) females, mean age 52.73 ± 13.76 years. Increased risk for aortic arch calcification was associated with higher PWV ratio even after adjustment for age, height, heart rate, ferritin level and C-reactive protein level (OR 2.59E+04, 95% CI 2.43E+01, 2.65E+09, p = 0.021). PWV ratio together with above-mentioned variables could predict the presence of aortic arch calcification with specificity of 93% (95% CI 78, 99%) and sensitivity of 53% (95% CI 34, 72%). The elastic and muscular arteries' stiffness mismatch was strongly associated with the extent of aortic arch calcification in this dialysis population and had better calcification predictive value compared to other demographic, hemodynamic and biochemical markers.
Chen, Shao-Wei; Huang, Yao-Kuang; Liao, Chien-Hung; Wang, Shang-Yu
2014-01-01
A 74-year old female was transferred to our institution because of blunt chest trauma. Chest X-ray and computed tomography (CT) revealed right haemothorax and little pericardial effusion. She was taken to the operating theatre for emergent operation because of hypotension and massive bleeding from the right-sided chest tube. Cardiopulmonary resuscitation was started during surgical exploration. There were three 1-cm lacerations actively bleeding from the right atrium and inferior vena cava junction, which were repaired successfully. Furthermore, we identified a 10 cm laceration in the right-side pleuropericardium and a communication existing between the pericardial space and the right pleural space. PMID:24218497
Chen, Shao-Wei; Huang, Yao-Kuang; Liao, Chien-Hung; Wang, Shang-Yu
2014-02-01
A 74-year old female was transferred to our institution because of blunt chest trauma. Chest X-ray and computed tomography (CT) revealed right haemothorax and little pericardial effusion. She was taken to the operating theatre for emergent operation because of hypotension and massive bleeding from the right-sided chest tube. Cardiopulmonary resuscitation was started during surgical exploration. There were three 1-cm lacerations actively bleeding from the right atrium and inferior vena cava junction, which were repaired successfully. Furthermore, we identified a 10 cm laceration in the right-side pleuropericardium and a communication existing between the pericardial space and the right pleural space.
Bekas, Marcin; Gajewski, Antoni K; Pachocki, Krzysztof
2013-01-01
Within the medical facilities provided by state healthcare services, a universally applied technique for patient diagnosis and treatment relies on ionising radiation; for example in radiotherapy and X-ray (ie. examination). Human exposure to such radiation is not however entirely free of associated health risks. To determine and estimate the numbers and types of X-ray based medical procedures that are performed in general and dental radiography, mammography and computer tomography on patients from the Mazovian province in Poland, which included children, women and men subjects. The numbers of patient subjects undergoing X-rays was estimated by surveying the patient intake in X-ray testing rooms within the healthcare facilities of the Mazovian province. Questionnaires were either dispatched by mail to such healthcare centres or were completed by the X-ray operating staff during the testing of quality control. Results so obtained from the latter, were compared to entries from the X-ray rooms' register During 2009, the number of X-rays performed were 7612046 equivalent to 1460 examinations per 1000 inhabitants. The majority were done on women ie. 3847961 (50.55%), followed by 3193781 (41.96%) on men and 570 304 (7.49%) for children. Results indicated that the predominating medical procedure used of this type, was for making general diagnoses; especially through using chest radiography. Others included, in descending order; dental X-ray (mainly intra-oral examination), computer tomography (mainly CT head examinations) and mammography procedures. It was also found that the annual numbers of having X-rays has increased compared to previous years.
Kim, Hee Sun; Yoo, Jeong Seon; Han, Seok Joo; Park, Hyojin
2007-01-01
The eventration of diaphragm is usually found incidentally on chest X-ray or sometimes presented as acute gastric volvulus. However, colonic volvulus on splenic flexure area complicated by diaphragmatic eventration is extremely rare. A 25 year old man complained of upper abdominal pain for three days. He had a history of brain injury during infant period, and had epilepsy and mental retardation. Plain chest X-ray showed left diaphragmatic eventration and marked dilatation of colon on splenic flexure area which had not been changed for last three years. Barium enema showed bird beak appearance on distal colon near the splenic flexure. Colonoscopic reduction failed. After decompression with rectal and nasogastric tubes, colonic volvulus was relieved. To prevent the recurrence of volvulus, we performed segmental resection of left colon including splenic flexure area and repaired the left diaphragmatic eventration. After the operation, the patient had no further recurrent episode of volvulus although ileus persisted.
Evaluation of thallium-201 scanning for detection of latent coronary artery disease
NASA Technical Reports Server (NTRS)
Johnson, P. C.; Leblanc, A.; Deboer, L.; Jhingran, S.
1978-01-01
The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.
INVASIVE SALMONELLOSIS PRESENTING AS A LUNG ABSCESS: A CASE REPORT.
Songkhla, Munjit Na; Chayakulkeeree, Methee
2017-01-01
Salmonella spp are an uncommon cause of lung abscess. A 59 year old man presented to our hospital with a 1 month history of cough and low grade fever progressing to high grade fever for 1 week. He had a past medical history significant for diabetes mellitus type 2 and focal segmental glomerulosclerosis for which he was receiving prednisolone, initially at 60 mg daily tapering to 20 mg daily. On presentation he was febrile and had decreased breath sounds and dullness to percussion over the right lower lung field. A chest X-ray showed a cavitary lesion with an air-fluid level in the right lung. Computed tomography of the lung revealed 2 cavitary lesions in the right upper and lower lungs. Sputum culture revealed Salmonella spp group B. He was treated successfully with ceftriaxone intravenously for 1 month followed by oral cefdinir. A chest X-ray at 1 month showed significant improvement; he was treated conservatively without surgical drainage. Salmonella can cause lung abscesses, especially in the immune suppressed.
Medici, S; Pitzschke, A; Cherbuin, N; Boldini, M; Sans-Merce, M; Damet, J
2017-11-01
The purpose of this work was to estimate the eye lens radiation exposure of the medical staff during interventional urology procedures. The measurements were carried out for six medical staff members performing 33 fluoroscopically-guided procedures. All procedures were performed with the X-ray tube positioned over the couch. The dose equivalents (H p (0.07)) were measured at the eye level using optically stimulated luminescent (OSL) dosimeters and at the chest level with OSL dosimeters placed over the protective apron. The ratio of the dose measured close to the eye lens and on the chest was determined. The annual eye lens dose was estimated based on the workload in the service. For the physician and the instrumentalist nurse, the eye to chest dose ratios were 0.9±0.4 and 2.6±1.6 (k = 2), respectively. The average doses per procedure received by the eye lens were 78±24 μSv and 38±18 μSv, respectively. The eye lens dose per DAP was 8.4±17.5 μSv/(Gy·cm 2 ) for the physician and 4.1±8.7 μSv/(Gy·cm 2 ) for the instrumentalist nurse. The results indicate that the eye lens to chest dose ratio greatly varies according to the staff function and that the dose equivalent measured by the personal dosimeter worn on the chest may underestimate the eye lens dose of some medical staff members. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Borrego, David; Lowe, Erin M; Kitahara, Cari M; Lee, Choonsik
2018-03-21
A PC Program for x ray Monte Carlo (PCXMC) has been used to calculate organ doses in patient dosimetry and for the exposure assessment in epidemiological studies of radiogenic health related risks. This study compared the dosimetry from using the built-in stylized phantoms in the PCXMC to that of a newer hybrid phantom library with improved anatomical realism. We simulated chest and abdominal x ray projections for 146 unique body size computational phantoms, 77 males and 69 females, with different combinations of height (125-180 cm) and weight (20-140 kg) using the built-in stylized phantoms in the PCXMC version 2.0.1.4 and the hybrid phantom library using the Monte Carlo N-particle eXtended transport code 2.7 (MCNPX). Unfortunately, it was not possible to incorporate the hybrid phantom library into the PCXMC. We compared 14 organ doses, including dose to the active bone marrow, to evaluate differences between the built-in stylized phantoms in the PCXMC and the hybrid phantoms (Cristy and Eckerman 1987 Technical Report ORNL/TM-8381/V1, Oak Ridge National Laboratory, Eckerman and Ryman 1993 Technical Report 12 Oak Ridge, TN, Geyer et al 2014 Phys. Med. Biol. 59 5225-42). On average, organ doses calculated using the built-in stylized phantoms in the PCXMC were greater when compared to the hybrid phantoms. This is most prominent in AP abdominal exams by an average factor of 2.4-, 2.8-, and 2.8-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. For chest exams, organ doses are greater by an average factor of 1.1-, 1.4-, and 1.2-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. The PCXMX, due to its ease of use, is often selected to support dosimetry in epidemiological studies; however, it uses simplified models of the human anatomy that fail to account for variations in body morphometry for increasing weight. For epidemiological studies that use PCXMC dosimetry, associations between radiation-related disease risks and organ doses may be underestimated, and to a greater degree in pediatric, especially obese pediatric, compared to adult patients.
NASA Astrophysics Data System (ADS)
Borrego, David; Lowe, Erin M.; Kitahara, Cari M.; Lee, Choonsik
2018-03-01
A PC Program for x ray Monte Carlo (PCXMC) has been used to calculate organ doses in patient dosimetry and for the exposure assessment in epidemiological studies of radiogenic health related risks. This study compared the dosimetry from using the built-in stylized phantoms in the PCXMC to that of a newer hybrid phantom library with improved anatomical realism. We simulated chest and abdominal x ray projections for 146 unique body size computational phantoms, 77 males and 69 females, with different combinations of height (125–180 cm) and weight (20–140 kg) using the built-in stylized phantoms in the PCXMC version 2.0.1.4 and the hybrid phantom library using the Monte Carlo N-particle eXtended transport code 2.7 (MCNPX). Unfortunately, it was not possible to incorporate the hybrid phantom library into the PCXMC. We compared 14 organ doses, including dose to the active bone marrow, to evaluate differences between the built-in stylized phantoms in the PCXMC and the hybrid phantoms (Cristy and Eckerman 1987 Technical Report ORNL/TM-8381/V1, Oak Ridge National Laboratory, Eckerman and Ryman 1993 Technical Report 12 Oak Ridge, TN, Geyer et al 2014 Phys. Med. Biol. 59 5225–42). On average, organ doses calculated using the built-in stylized phantoms in the PCXMC were greater when compared to the hybrid phantoms. This is most prominent in AP abdominal exams by an average factor of 2.4-, 2.8-, and 2.8-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. For chest exams, organ doses are greater by an average factor of 1.1-, 1.4-, and 1.2-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. The PCXMX, due to its ease of use, is often selected to support dosimetry in epidemiological studies; however, it uses simplified models of the human anatomy that fail to account for variations in body morphometry for increasing weight. For epidemiological studies that use PCXMC dosimetry, associations between radiation-related disease risks and organ doses may be underestimated, and to a greater degree in pediatric, especially obese pediatric, compared to adult patients.
Erdman, Laura K.; D’Acremont, Valérie; Hayford, Kyla; Kilowoko, Mary; Kyungu, Esther; Hongoa, Philipina; Alamo, Leonor; Streiner, David L.; Genton, Blaise; Kain, Kevin C.
2015-01-01
Background Diagnosing pediatric pneumonia is challenging in low-resource settings. The World Health Organization (WHO) has defined primary end-point radiological pneumonia for use in epidemiological and vaccine studies. However, radiography requires expertise and is often inaccessible. We hypothesized that plasma biomarkers of inflammation and endothelial activation may be useful surrogates for end-point pneumonia, and may provide insight into its biological significance. Methods We studied children with WHO-defined clinical pneumonia (n = 155) within a prospective cohort of 1,005 consecutive febrile children presenting to Tanzanian outpatient clinics. Based on x-ray findings, participants were categorized as primary end-point pneumonia (n = 30), other infiltrates (n = 31), or normal chest x-ray (n = 94). Plasma levels of 7 host response biomarkers at presentation were measured by ELISA. Associations between biomarker levels and radiological findings were assessed by Kruskal-Wallis test and multivariable logistic regression. Biomarker ability to predict radiological findings was evaluated using receiver operating characteristic curve analysis and Classification and Regression Tree analysis. Results Compared to children with normal x-ray, children with end-point pneumonia had significantly higher C-reactive protein, procalcitonin and Chitinase 3-like-1, while those with other infiltrates had elevated procalcitonin and von Willebrand Factor and decreased soluble Tie-2 and endoglin. Clinical variables were not predictive of radiological findings. Classification and Regression Tree analysis generated multi-marker models with improved performance over single markers for discriminating between groups. A model based on C-reactive protein and Chitinase 3-like-1 discriminated between end-point pneumonia and non-end-point pneumonia with 93.3% sensitivity (95% confidence interval 76.5–98.8), 80.8% specificity (72.6–87.1), positive likelihood ratio 4.9 (3.4–7.1), negative likelihood ratio 0.083 (0.022–0.32), and misclassification rate 0.20 (standard error 0.038). Conclusions In Tanzanian children with WHO-defined clinical pneumonia, combinations of host biomarkers distinguished between end-point pneumonia, other infiltrates, and normal chest x-ray, whereas clinical variables did not. These findings generate pathophysiological hypotheses and may have potential research and clinical utility. PMID:26366571
Significance of serum mesothelin in an asbestos-exposed population in the Czech Republic.
Jakubec, Petr; Pelclova, Daniela; Smolkova, Petra; Kolek, Vitezslav; Nakladalova, Marie
2015-09-01
Pleural mesothelioma is a highly aggressive and difficult-to-treat form of cancer induced by asbestos in 80-90% of cases. The population group most at risk of the condition are asbestos-exposed workers. Mesothelin or soluble mesothelin-related protein (SMRP) is studied as a potential marker of mesothelioma in the at-risk population. The study comprised 239 subjects with a mean duration of occupational exposure to asbestos of 19.9 years. In all of them, a complete medical history was taken, focused on exposure duration and a physical examination, a chest X-ray or other imaging investigations and a lung function test were performed. Their serum SMRP levels were measured and biopsy samples were taken to diagnose pleural disease. Based on the above examinations, the subjects were classified into subgroups and serum SMRP concentrations were statistically analyzed with respect to individual parameters. In asbestos-exposed individuals, mesothelin levels were significantly higher in those with pathological X-ray findings than in those with normal X-ray results (0.78 ± 0.63 vs. 0.50 ± 0.35, P<0.0001). The group of patients with benign disease had statistically significantly higher mesothelin levels than those with normal X-ray findings (0.755 ± 0.543 vs. 0.50 ± 0.35, P<0.001). In the group with present malignant processes, mesothelin levels were higher than in individuals with benign disease (1.19 ± 0.89 vs. 0.76 ± 0.54, P=0.015). Only a weak correlation was found between mesothelin levels and asbestos exposure duration. There were relatively high sensitivity and high specificity (75% and 90.6%, respectively) of serum mesothelin for pleural mesothelioma. However, given the small number of mesothelioma cases in the group, the results cannot be considered as statistically significant. In persons followed up for asbestos exposure, increased mesothelin levels signalize pathological processes in the chest and correlate with severity of the disease. The study suggests that mesothelin cannot be considered a reliable marker for the early stage of malignant degeneration of pleural disease but only an additional criterion for examination of the followed-up individuals.
A simple diagnostic model for ruling out pneumoconiosis among construction workers.
Suarthana, Eva; Moons, Karel G M; Heederik, Dick; Meijer, Evert
2007-09-01
Construction workers exposed to silica-containing dust are at risk of developing silicosis even at low exposure levels. Health surveillance among these workers is commonly advised but the exact diagnostic work-up is not specified and therefore may result in unnecessary chest x ray investigations. To develop a simple diagnostic model to estimate the probability of an individual worker having pneumoconiosis from questionnaire and spirometry results, in order to accurately rule out workers without pneumoconiosis. The study was performed using cross-sectional data of 1291 Dutch natural stone and construction workers with potentially high quartz dust exposure. A multivariable logistic regression model was developed using chest x ray with ILO profusion category > or =1/1 as the reference standard. The model's calibration was evaluated with the Hosmer-Lemeshow test; the discriminative ability was determined by calculating the area under the receiver operating characteristic curve (ROC area). Internal validity of the final model was assessed by a bootstrapping procedure. For clinical application, the diagnostic model was transformed into an easy-to-use score chart. Age 40 years or older, current smoker, high-exposure job, working 15 years or longer in the construction industry, "feeling unhealthy" and FEV1 were independent predictors in the diagnostic model. The model showed good calibration (a non-significant Hosmer-Lemeshow test) and discriminative ability (ROC area 0.81, 95% CI 0.74 to 0.85). Internal validity was reasonable; the optimism corrected ROC area was 0.76. By using a cut-off point with a high negative predictive value the occupational physician can efficiently detect a large proportion of workers with a low probability of having pneumoconiosis and exclude them from unnecessary x ray investigations. This diagnostic model is an efficient and effective instrument to rule out pneumoconiosis among construction workers. Its use in health surveillance among these workers can reduce the number of redundant x ray investigations.
Brady, S L; Kaufman, R A
2015-05-01
To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k air) value based on an x-ray characteristic radiation output curve; (2) scaling k air with a BSF value; and (3) correcting k air for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass-energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19-0.42 mGy for dual view chest, 0.28-1.2 mGy for AP abdomen, 0.18-0.65 mGy for LAT view skull, 0.15-0.63 mGy for dual view knee, and 0.10-0.12 mGy for bone age (left hand) examinations. A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brady, S. L., E-mail: samuel.brady@stjude.org; Kaufman, R. A., E-mail: robert.kaufman@stjude.org
Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken frommore » DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.« less
TU-CD-207-10: Dedicated Cone-Beam Breast CT: Design of a 3-D Beam-Shaping Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vedantham, S; Shi, L; Karellas, A
2015-06-15
Purpose: To design a 3 -D beam-shaping filter for cone-beam breast CT for equalizing x-ray photon fluence incident on the detector along both fan and cone angle directions. Methods: The 3-D beam-shaping filter was designed as the sum of two filters: a bow-tie filter assuming cylindrical breast and a 3D difference filter equivalent to the difference in projected thickness between the cylinder and the real breast. Both filters were designed with breast-equivalent material and converted to Al for the targeted x-ray spectrum. The bow-tie was designed for the largest diameter cylindrical breast by determining the fan-angle dependent path-length and themore » filter thickness needed to equalize the fluence. A total of 23,760 projections (180 projections of 132 binary breast CT volumes) were averaged, scaled for the largest breast, and subtracted from the projection of the largest diameter cylindrical breast to provide the 3D difference filter. The 3 -D beam shaping filter was obtained by summing the two filters. Numerical simulations with semi-ellipsoidal breasts of 10–18 cm diameter (chest-wall to nipple length=0.75 x diameter) were conducted to evaluate beam equalization. Results: The proposed 3-D beam-shaping filter showed a 140% -300% improvement in equalizing the photon fluence along the chest-wall to nipple (cone-angle) direction compared to a bow-tie filter. The improvement over bow-tie filter was larger for breasts with longer chest-wall to nipple length. Along the radial (fan-angle) direction, the performance of the 3-D beam shaping filter was marginally better than the bow-tie filter, with 4%-10% improvement in equalizing the photon fluence. For a ray traversing the chest-wall diameter of the breast, the filter transmission ratio was >0.95. Conclusion: The 3-D beam shaping filter provided substantial advantage over bow-tie filter in equalizing the photon fluence along the cone-angle direction. In conjunction with a 2-axis positioner, the filter can accommodate breasts of varying dimensions and chest-wall inclusion. Supported in part by NIH R01 CA128906 and R21 CA134128. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.« less
Organ dose and risk assessment in paediatric radiography using the PCXMC 2.0
NASA Astrophysics Data System (ADS)
Ladia, A.; Messaris, G.; Delis, H.; Panayiotakis, G.
2015-09-01
Abdominal and chest radiographs are the most common examinations in paediatric radiology. X-ray examination of children attracts particular interest, mainly due to the increased risk for the expression of delayed radiogenic cancers as they have many years of expected life remaining. This study aims to calculate the organ dose and estimate the radiation Risk of Exposure Induced cancer Death (REID) to paediatric patients, using the PCXMC 2.0 Monte Carlo code.Patient data and exposure parameters were recorded during examinations of 240 patients, separated in four age groups undergoing chest or abdomen examinations.The organs received the highest dose in all patient groups were liver, lungs, stomach, thyroid, pancreas, breast, spleen in chest radiographs and liver, lungs, colon, stomach and ovaries, uterus (for girls) and prostate (for boys) in abdomen radiographs. The effective dosefor the chest was 0.49×10-2- 1.07×10-2 mSv, while for the abdomen 1.85×10-2- 3.02×10-2 mSv. The mean REID value was 1.254×10-5 for the abdomen and 0.645×10-5 for the chest.
Inadvertent positioning of pacemaker leads in the pericardium.
Berenji, Kambeez; Nerheim, Pamela; Olshansky, Brian
2003-10-01
A patient had a dual chamber pacemaker with endocardial leads implanted chronically. The lead position on chest X ray and the ECG pattern indicated lead malposition, but a CT scan and transesophageal echocardiography were nondiagnostic. Venography indicated that both leads were in the mediastinal and pericardial space.
A case report on bronchoalveolar carcinoma presenting as non-resolving consolidation.
Shoib, Sheikh; Malik, Javid A; Arif, Tasleem; Bashir, Haamid
2012-08-01
Bronchoalveolar carcinoma presenting as non-resolving consolidation is an uncommon presentation. The typical presentation of bronchoalveolar carcinoma is asymptomatic (solitary nodule) and remains without symptoms even as disease disseminates. We report a case of bronchoalveolar carcinoma presenting as non-resolving consolidation in a young male with productive cough, exertional breathlessness and physical examination revealing the features of right lower consolidation on x-ray chest, with subsequent CT of the chest and bronchoscopic examination revealed bronchoalveolar carcinoma. Patient had a good score and was managed conservatively.
A diagnostic dilemma of right lower lobe collapse caused by pulmonary bilharsiasis.
Sersar, Sameh Ibrahim; Abulmaaty, Reda Ahmed; Elnahas, Hala Ahmed; Moussa, Sherif Abdou; Shiha, Usama A; Ghafar, Wael A Abdel; Elmotawaly, Raed A
2006-02-01
A 32-year-old male was presented with massive haemoptysis. An urgent chest X-ray (Fig. 1a) and CT chest (Fig. 1b-e) was done revealing a right lower lobe consolidation collapse. An urgent rigid bronchoscopy was performed to localize the source of bleeding and try to control it. A right lower lobectomy was done using a double-lumen endotracheal tube. Preoperative and intraoperative impressions of non-specific inflammation were accused to be the aetiology. Histopathology revealed pulmonary venous congestion with bilharsial ova.
2010-01-01
Background A previous study showed that combination of zinc and vitamin A reduced sputum conversion time in pulmonary tuberculosis (TB) patients. Objective We studied the efficacy of which single micronutrient contributed more to the sputum conversion time. Methods In a double-blind randomized community trial, newly sputum smear positive pulmonary TB patients were assigned randomly to receive zinc, vitamin A, zinc + vitamin A or placebo on top of TB treatment. Patients were asked to deliver their sputum on weekly basis to measure positivity of the bacteria. Nutritional status, chest x-ray, hemoglobin, C-reactive protein (CRP), retinol and zinc level were examined prior to, after 2 and 6 months of treatment. Results Initially, 300 patients were enrolled, and 255 finished the treatment. Most patients were severely malnourished (mean BMI 16.5 ± 2.2 Kg/m2). Patients in the zinc + vitamin A group showed earlier sputum conversion time (mean 1.9 weeks) compared with that in the other groups; however the difference was not significant. Also, no benefit could be demonstrated of any of the used supplementations on clinical, nutritional, chest x-ray, or laboratory findings. Conclusions This study among severely malnourished TB patients, did not confirm that single or combined supplementation of zinc and vitamin A significantly reduced sputum conversion time or had other significant benefit. PMID:20920186
Pakasi, Trevino A; Karyadi, Elvina; Suratih, Ni Made Desy; Salean, Michael; Darmawidjaja, Nining; Bor, Hans; van der Velden, Koos; Dolmans, Wil M V; van der Meer, Jos W M
2010-09-28
A previous study showed that combination of zinc and vitamin A reduced sputum conversion time in pulmonary tuberculosis (TB) patients. We studied the efficacy of which single micronutrient contributed more to the sputum conversion time. In a double-blind randomized community trial, newly sputum smear positive pulmonary TB patients were assigned randomly to receive zinc, vitamin A, zinc + vitamin A or placebo on top of TB treatment. Patients were asked to deliver their sputum on weekly basis to measure positivity of the bacteria. Nutritional status, chest x-ray, hemoglobin, C-reactive protein (CRP), retinol and zinc level were examined prior to, after 2 and 6 months of treatment. Initially, 300 patients were enrolled, and 255 finished the treatment. Most patients were severely malnourished (mean BMI 16.5 ± 2.2 Kg/m2). Patients in the zinc + vitamin A group showed earlier sputum conversion time (mean 1.9 weeks) compared with that in the other groups; however the difference was not significant. Also, no benefit could be demonstrated of any of the used supplementations on clinical, nutritional, chest x-ray, or laboratory findings. This study among severely malnourished TB patients, did not confirm that single or combined supplementation of zinc and vitamin A significantly reduced sputum conversion time or had other significant benefit.
[Recurrent pulmonary infarction associated with familial protein S deficiency type III].
Ide, K; Chida, K; Suda, T; Imokawa, S; Tsukamoto, K; Todate, A; Sato, J; Yonekawa, O; Nakamura, H
1999-05-01
A 38-year-old woman was admitted to our hospital because of recurrent chest pain and fever. Chest X-ray films and computed tomograms showed subpleural consolidation containing small cavity-like opacities. Open lung biopsy revealed non-infectious abscess and vessels with organizing thrombus. The patient was given a diagnosis of pulmonary infarction due to the existence of deep venous thrombosis. Coagulation studies demonstrated that she had decreased plasma protein S activity, whereas her free and total protein S antigen levels were normal. Because her mother and maternal uncle and aunt also demonstrated decreased protein S activity with normal plasma protein S antigen levels, the patient was considered to be affected by familial protein S deficiency type III.
NASA Astrophysics Data System (ADS)
Hassan, G. M.; Rabie, N.; Mustafa, K. A.; Abdel-Khalik, S. S.
2012-09-01
Radiation exposure and image quality in X-ray diagnostic radiology provide a clear understanding of the relationship between the radiation dose delivered to a patient and image quality in optimizing medical diagnostic radiology. Because a certain amount of radiation is unavoidably delivered to patients, this should be as low as reasonably achievable. Several X-ray diagnostic machines were used at different medical diagnostic centers in Egypt for studying the beam quality and the dose delivered to the patient. This article studies the factors affecting the beam quality, such as the kilo-volt peak (kVp), exposure time (mSc), tube current (mAs) and the absorbed dose in (μGy) for different examinations. The maximum absorbed dose measured per mAs was 594±239 and 12.5±3.7 μGy for the abdomen and the chest, respectively, while the absorbed dose at the elbow was 18±6 μGy, which was the minimum dose recorded. The compound and expanded uncertainties accompanying these measurements were 4±0.35% and 8±0.7%, respectively. The measurements were done through quality control tests as acceptance procedures.
Diffuse lung uptake (DLU) on Ga-67 scintigraph: Clinical, radiologic and pathologic correlation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sy, W.M.; Seo, I.S.; Vieira, J.
1985-05-01
Review, analysis and correlation (clinical, radiologic and pathologic) of 29 consecutive adults (16 drug addicts and/or homosexuals) with DLU on Ga-67 scintigraph were made. Diffuse increased uptake of at least 75% of both lungs was considered as DLU. WFOF cameras were used to obtain 24 to 96 hr. scintigraphs after IV injection of 3-5 mCi of Ga-67 citrate. In 26, tissue diagnosis established: pneumocystis carinii (PC) 15, miliary tuberculosis (TB) 3, sarcoidosis (SR) 3, drug-induced toxicity 2, and toxoplasmosis (TX), primary hyperparathyroidism and nonspecific lymphocytic pneumonia-one each. In two with breast and one with esophageal carcinomas, no lung tissue diagnosismore » was sought. Concurrent chest x-rays were negative in 16, but in 7/16, lung infiltrate was later documented. An average of 31 days elapsed before x-rays became positive in four with PC, 7 days in two with TB, and 22 days in one with TX. In 13, concurrent x-rays showed lung infiltrate, but in 6, only subtle, localized rather than diffuse infiltrate was noted. Fourteen of 29 had at least two Ga-67 studies. In 12 (7 PC, 2 TB, 3 SR) of 14 whose repeat studies showed significant to total disappearance of DLU, all did well clinically. In two whose initial studies were negative or equivocal, they became clinically worse when the repeat study showed DLU. In three others (2 PC, 1 TX) who died, their single studies recorded intense DLU. DLU on gallium scintigraph indicated a variety of pathology. In 55.2%, gallium scintigraph predated x-ray findings by a few days to weeks. In 20.3%, x-ray findings were only subtle or localized. Scintigraphic changes correlated well with the clinical courses in various diseases.« less
Characterisation of an anthropomorphic chest phantom for dose measurements in radiology beams
NASA Astrophysics Data System (ADS)
Henriques, L. M. S.; Cerqueira, R. A. D.; Santos, W. S.; Pereira, A. J. S.; Rodrigues, T. M. A.; Carvalho Júnior, A. B.; Maia, A. F.
2014-02-01
The objective of this study was to characterise an anthropomorphic chest phantom for dosimetric measurements of conventional radiology beams. This phantom was developed by a previous research project at the Federal University of Sergipe for image quality control tests. As the phantom consists of tissue-equivalent material, it is possible to characterise it for dosimetric studies. For comparison, a geometric chest phantom, consisting of PMMA (polymethylmethacrylate) with dimensions of 30×30×15 cm³ was used. Measurements of incident air kerma (Ki) and entrance surface dose (ESD) were performed using ionisation chambers. From the results, backscatter factors (BSFs) of the two phantoms were determined and compared with values estimated by CALDose_X software, based on a Monte Carlo simulation. For the technical parameters evaluated in this study, the ESD and BSF values obtained experimentally showed a good similarity between the two phantoms, with minimum and maximum difference of 0.2% and 7.0%, respectively, and showed good agreement with the results published in the literature. Organ doses and effective doses for the anthropomorphic phantom were also estimated by the determination of conversion coefficients (CCs) using the visual Monte Carlo (VMC) code. Therefore, the results of this study prove that the anthropomorphic thorax phantom proposed is a good tool to use in dosimetry and can be used for risk evaluation of X-ray diagnostic procedures.
Radioactive seed migration following parotid gland interstitial brachytherapy.
Fan, Yi; Huang, Ming-Wei; Zhao, Yi-Jiao; Gao, Hong; Zhang, Jian-Guo
To evaluate the incidence and associated factors of pulmonary seed migration after parotid brachytherapy using a novel migrated seed detection technique. Patients diagnosed with parotid cancer who underwent permanent parotid brachytherapy from January 2006 to December 2011 were reviewed retrospectively. Head and neck CT scans and chest X-rays were evaluated during routine follow-up. Mimics software and Geomagic Studio software were used for seed reconstruction and migrated seed detection from the original implanted region, respectively. Postimplant dosimetry analysis was performed after seeds migration if the seeds were still in their emitting count. Adverse clinical sequelae from seed embolization to the lung were documented. The radioactive seed implants were identified on chest X-rays in 6 patients. The incidence rate of seed migration in 321 parotid brachytherapy patients was 1.87% (6/321) and that of individual seed migration was 0.04% (6/15218 seeds). All migrated seeds were originally from the retromandibular region. No adverse dosimetric consequences were found in the target region. Pulmonary symptoms were not reported by any patient in this study. In our patient set, migration of radioactive seeds with an initial radioactivity of 0.6-0.7 mCi to the chest following parotid brachytherapy was rare. Late migration of a single seed from the central target region did not affect the dosimetry significantly, and patients did not have severe short-term complications. This study proposed a novel technique to localize the anatomical origin of the migrated seeds during brachytherapy. Our evidence suggested that placement of seeds adjacent to blood vessels was associated with an increased likelihood of seed migration to the lungs. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Wood, T J; Beavis, A W; Saunderson, J R
2013-01-01
Objective: The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. Methods: The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson’s correlation coefficient. Results: Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Conclusion: Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. Advances in knowledge: A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography. PMID:23568362
Anthropometry of Airline Stewardesses
1975-03-01
to obtain a nude bust circumference on each applicant as she presented herself for a routine chest X-ray. Since a number of subjects had been... girls as short as 5 feet 1 inch and one (Air West) takes girls as short as 5 feet.* At the other extreme, several will not accept applicants shorter
Lung Cancer Screening (PDQ®)—Health Professional Version
Lung cancer screening with low-dose spiral CT scans has been shown to decrease the risk of dying from lung cancer in heavy smokers. Screening with chest x-ray or sputum cytology does not reduce lung cancer mortality. Get detailed information about lung cancer screening in this clinician summary.
Health Effects of Hexachloroethane (HC) Smoke
1994-02-08
subnormal lung function continued twelve months after his exposure, but his chest x-ray had returned to normal by that time-an unusual finding in this...schedule. In males, renal neoplasms were found in 1/50, 2/50, and 7/50 in the respective treatment groups- and adrenal gland pheochromocytomas were
Difference Between Latent TB Infection and Active TB Disease
... chest x-ray, or positive sputum smear or culture • • Has active TB bacteria in his/her body • • Usually feels sick and may have symptoms such as coughing, fever, and weight loss • • May spread TB bacteria to others • • Needs treatment ...
1965-12-02
S65-56315 (2 Dec. 1965) --- Dr. Charles A. Berry (left), chief of the Manned Spacecraft Center (MSC) Medical Programs, and astronauts James A. Lovell Jr. (center), Gemini-7 pilot, and Frank Borman, Gemini-7 command pilot, examine a series of chest x-rays taken during the preflight physical. Photo credit: NASA
20 CFR 718.104 - Report of physical examinations.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) The miner's medical and employment history; (2) All manifestations of chronic respiratory disease; (3) Any pertinent findings not specifically listed on the form; (4) If heart disease secondary to lung disease is found, all symptoms and significant findings; (5) The results of a chest X-ray conducted and...
20 CFR 718.104 - Report of physical examinations.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) The miner's medical and employment history; (2) All manifestations of chronic respiratory disease; (3) Any pertinent findings not specifically listed on the form; (4) If heart disease secondary to lung disease is found, all symptoms and significant findings; (5) The results of a chest X-ray conducted and...
20 CFR 718.104 - Report of physical examinations.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) The miner's medical and employment history; (2) All manifestations of chronic respiratory disease; (3) Any pertinent findings not specifically listed on the form; (4) If heart disease secondary to lung disease is found, all symptoms and significant findings; (5) The results of a chest X-ray conducted and...
20 CFR 718.104 - Report of physical examinations.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) The miner's medical and employment history; (2) All manifestations of chronic respiratory disease; (3) Any pertinent findings not specifically listed on the form; (4) If heart disease secondary to lung disease is found, all symptoms and significant findings; (5) The results of a chest X-ray conducted and...
29 CFR 1910.1020 - Access to employee exposure and medical records.
Code of Federal Regulations, 2012 CFR
2012-07-01
... results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray examinations taken for the purposes of establishing a base-line...), the employer shall prominently post a copy of the written access order and its accompanying cover...
29 CFR 1910.1020 - Access to employee exposure and medical records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray examinations taken for the purposes of establishing a base-line...), the employer shall prominently post a copy of the written access order and its accompanying cover...
29 CFR 1910.1020 - Access to employee exposure and medical records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... results of medical examinations (pre-employment, pre-assignment, periodic, or episodic) and laboratory tests (including chest and other X-ray examinations taken for the purposes of establishing a base-line...), the employer shall prominently post a copy of the written access order and its accompanying cover...
Kim, Tae-Hoon; Heo, Dong-Woon; Jeong, Chang-Won; Ryu, Jong-Hyun; Jun, Hong Young; Han, Seung-Jun; Ha, Taeuk; Yoon, Kwon-Ha
2017-01-01
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines. PMID:28272336
Wen, Di; Nye, Katelyn; Zhou, Bo; Gilkeson, Robert C; Gupta, Amit; Ranim, Shiraz; Couturier, Spencer; Wilson, David L
2018-03-01
We have developed a technique to image coronary calcium, an excellent biomarker for atherosclerotic disease, using low cost, low radiation dual energy (DE) chest radiography, with potential for widespread screening from an already ordered exam. Our dual energy coronary calcium (DECC) processing method included automatic heart silhouette segmentation, sliding organ registration and scatter removal to create a bone-image-like, coronary calcium image with significant reduction in motion artifacts and improved calcium conspicuity compared to standard, clinically available DE processing. Experiments with a physical dynamic cardiac phantom showed that DECC processing reduced 73% of misregistration error caused by cardiac motion over a wide range of heart rates and x-ray radiation exposures. Using the functional measurement test (FMT), we determined significant image quality improvement in clinical images with DECC processing (p < 0.0001), where DECC images were chosen best in 94% of human readings. Comparing DECC images to registered and projected CT calcium images, we found good correspondence between the size and location of calcification signals. In a very preliminary coronary calcium ROC study, we used CT Agatston calcium score >50 as the gold standard for an actual positive test result. AUC performance was significantly improved from 0.73 ± 0.14 with standard DE to 0.87 ± 0.10 with DECC (p = 0.0095) for this limited set of surgical patient data biased towards heavy calcifications. The proposed DECC processing shows good potential for coronary calcium detection in DE chest radiography, giving impetus for a larger clinical evaluation. Copyright © 2018. Published by Elsevier Ltd.
Kim, Tae-Hoon; Heo, Dong-Woon; Jeong, Chang-Won; Ryu, Jong-Hyun; Jun, Hong Young; Han, Seung-Jun; Ha, Taeuk; Yoon, Kwon-Ha
2017-03-07
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles ( p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.
Intra-Aortic Missile After Gunshot Wound to Chest: An Interesting Case of Traumatic Cardiac Injury.
Fraser, Charles D; Goeddel, Lee; Patel, Nishant D; Azoury, Said C; Grimm, Joshua C; Sheinberg, Rosanne B; Sciortino, Christopher M
2017-05-01
Missile embolus to the heart, although uncommon, is one of the most challenging scenarios in trauma. We describe a 36-year-old man who presented with a gunshot wound to the left chest and a chest x-ray revealing a foreign body in the mediastinum. A median sternotomy was performed and an injury to the left ventricle was identified. After intraoperative echocardiography and fluoroscopy confirmed a foreign body in the aortic root, cardiopulmonary bypass was implemented. A bullet was retrieved from the noncoronary sinus of the aortic valve. Injuries to the anterior leaflet of the mitral valve and left ventricle were repaired. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
SU-E-I-71: KVp Dependence of Transmitted Exposure for a Radiography Unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Y; Lynch, D; So, J
2014-06-01
Purpose: To investigate the kVp dependence of the transmitted exposure for a radiography x-ray unit. Methods: The study used a GE DiscoveryTM XR656 DR unit, a 30 (L) × 30 (W) × 25 cm thick Lucite phantom, two anthropomorphic phantoms (an Alderson RS-310 chest phantom and a 3M skull phantom), an Unfors detector, and a Radcal 10x9-6 ion chamber. We measured the entrance exposure and transmitted exposure of each phantom at 60, 70, 80, 90, 100, 110, 120 kVp for mAs range from 2.5 to 200 mAs, without any additional filter. The FOV is 30×30 cm for the Lucite andmore » chest phantom (AP view), and 20×20 cm for skull phantom (Lateral view). The transmitted exposure was measured at the phantom center of the x-ray exit side. For chest phantom, the transmitted exposures at 3 inch upper right and upper left from the center were also measured. We also checked the reproducibility and accuracy of the DR unit. Results: For each phantom, at every kVp and mAs setting, the transmitted exposure per mAs was calculated and normalized by the relative entrance exposure; the averaged transmitted exposure per mAs at each specific kVp was then determined. For chest phantom, the mean transmitted exposure per mAs was the average of three exit locations. The averaged transmitted exposure per mAs was fit as a power function of kVp. The result showed the transmitted exposure per mAs was approximately proportional to third power of the kVp for two anthropomorphic phantoms and forth power of the kVp for the Lucite phantom. Conclusion: The traditional assumption of fifth power kVp dependence to the transmitted exposure is inaccurate. At the normal radiography kVp range, the transmitted exposure is approximately proportional to third power of the kVp for a typical patient and up to forth power of the kVp for a large patient.« less
Omar, Artur; Marteinsdottir, Maria; Kadesjö, Nils; Fransson, Annette
2015-06-01
The International Commission on Radiological Protection (ICRP) has recommended that the occupational dose limit to the eye lens be substantially reduced. To ensure compliance with these recommendations, monitoring of the occupational eye lens dose is essential in certain hospital work environments. For assessment of the eye lens dose it is recommended to use a supplementary dosimeter placed at a position adjacent to the eye(s). Wearing a dosimeter at eye level can, however, be impractical and distributing and managing additional dosimeters over long periods of time is cumbersome and costly for large clinical sites. An attractive alternative is to utilize active personal dosimeters (APDs), which are routinely used by clinical staff for real-time monitoring of the personal dose equivalent rate (H(p)(10)). In this work, a formalism for the determination of eye lens dose from the response of such APD's worn on the chest is proposed and evaluated. The evaluation is based on both phantom and clinical measurements performed in an x-ray angiography suite for interventional cardiology. The main results show that the eye lens dose to the primary operator and to the assisting clinical staff can be conservatively estimated from the APD response as D(eye)(conductor) = 2.0 APD chest and D(eye)(assisting) = 1.0 APD chest, respectively. However, care should be exercised for particularly short assisting staff and if radiation protection shields are misused. These concerns can be greatly mitigated if the clinical staff are provided with adequate radiation protection training.
Drögemüller, A; Zahn, R; Bergmeier, C; Werling, C; Isgro, F; Senges, J
1998-08-01
In this case report a 65-year-old patient came into the emergency ward with acute chest pain after coronary artery bypass graft operation in 1985. On routine chest X-ray in 1995 a mediastinal widening was diagnosed. The chest X-ray in 1997 (Figure 1) showed an increase of the diameter of the known mediastinal widening. Therefore a CT-scan was performed (Figures 2a and 2b). This showed an enhancement of contrast material in a contained structure, without identifying its origin. Therefore a coronary angiography was done. Here, we diagnosed a contained disruption of the aorta at the insertion site of the bypass graft at the right coronary artery. Figure 3a shows leakage of contrast material out of the aorta into the pseudoaneurysm and in Figure 3b this is demonstrated in a schematic drawing. Figure 4a shows supraselective imaging of the pseudoaneurysm, demonstrated in a schematic drawing in Figure 4b. As the chest pain could only be handled by i.v.-medication, betablocker and bed rest we decided to operate. Intra-operatively the diagnosis was confirmed (Figure 5a and 5b). Postoperatively the patient died due to cerebral ischemia. Despite the lethal outcome an operative revision appears even retrospectively justified because of the increasing size of the pseudoaneurysm in addition to new symptoms that were difficult to treat. On the other hand there are no data available in order to estimate the risk of a spontaneous course.
[Optimal beam quality for chest digital radiography].
Oda, Nobuhiro; Tabata, Yoshito; Nakano, Tsutomu
2014-11-01
To investigate the optimal beam quality for chest computed radiography (CR), we measured the radiographic contrast and evaluated the image quality of chest CR using various X-ray tube voltages. The contrast between lung and rib or heart increased on CR images obtained by lowering the tube voltage from 140 to 60 kV, but the degree of increase was less. Scattered radiation was reduced on CR images with a lower tube voltage. The Wiener spectrum of CR images with a low tube voltage showed a low value under identical conditions of amount of light stimulated emission. The quality of chest CR images obtained using a lower tube voltage (80 kV and 100 kV) was evaluated as being superior to those obtained with a higher tube voltage (120 kV and 140 kV). Considering the problem of tube loading and exposure in clinical applications, a tube voltage of 90 to 100 kV (0.1 mm copper filter backed by 0.5 mm aluminum) is recommended for chest CR.
Patient doses from chest radiography in Victoria.
Cardillo, I; Boal, T J; Einsiedel, P F
1997-06-01
This survey examines doses from PA chest radiography at radiology practices, private hospitals and public hospitals throughout metropolitan and country Victoria. Data were collected from 111 individual X-ray units at 86 different practices. Entrance skin doses in air were measured for exposure factors used by the centre for a 23 cm thick male chest. A CDRH LucA1 chest phantom was used when making these measurements. About half of the centres used grid technique and half used non-grid technique. There was a factor of greater than 10 difference in the entrance dose delivered between the highest dose centre and the lowest dose centre for non-grid centres; and a factor of about 5 for centres using grids. Factors contributing to the high doses recorded at some centres were identified. Guidance levels for chest radiography based on the third quartile value of the entrance doses from this survey have been recommended and compared with guidance levels recommended in other countries.
Markel, Troy A; Kumar, Rajiv; Koontz, Nicholas A; Scherer, L R; Applegate, Kimberly E
2009-07-01
There is a growing concern that computed tomography (CT) is being unnecessarily overused for the evaluation of pediatric patients. The purpose of this study was to analyze the trends and utility of chest CT use compared with chest X-ray (CXR) for the evaluation of children with blunt chest trauma. A 4-year retrospective review was performed for pediatric patients who underwent chest CT within 24 hours of sustaining blunt trauma at a Level-I trauma center. Trends in the use of CT and CXR were documented, and results of radiology reports were analyzed and compared with clinical outcomes. Three hundred thirty-three children, mean age 11 years, had chest CTs, increasing from 5.5% in 2001-2002 to 10.5% in 2004-2005 (p < 0.001). Conversely, in those children who underwent chest CT, the rate of initial CXR use decreased from 84% to 56% during the same period (p < 0.001). Twenty percent of chest CTs had significant positive findings. Six patients underwent emergency surgery for cardiac or arterial injuries, and all demonstrated abnormal findings on CXR or CT scout imaging. When compared with the CT, only 5% of initial CXRs falsely reported normal findings that may have altered management. CT use in children has increased rapidly for the initial evaluation of chest trauma, whereas CXR use has decreased. Despite this trend, CXR remains an acceptable screening tool to analyze which patients may require CT evaluation. A multidisciplinary approach is warranted to develop guidelines that standardize the use of CT and thereby decreases unnecessary radiation exposure to pediatric patients.
Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.
Sano, Atsushi
2018-05-01
The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography. Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window. In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case. In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Russo, Paolo; Coppola, Teresa; Mettivier, Giovanni
2010-08-01
Cone-Beam Breast Computed Tomography (CBBCT) of the pendant breast with dedicated scanners is an experimental 3D X-ray imaging technique for breast cancer diagnosis under evaluation in comparison to conventional two-view 2-D mammography of the compressed breast. In CBBCT it is generally assumed that a more uniform distribution of the radiation dose to the breast volume can be obtained, with respect to mammography, at equal Mean Glandular Dose (MGD) levels. In fact, in CBBCT the X-ray beam rotates for 360 deg around the breast, while in each mammography view the breast is irradiated from one side only. Using a CBBCT laboratory scanner developed by our group, we have measured the distribution of the radiation dose in a hemi-ellipsoidal PMMA breast phantom of 14 cm diameter simulating the average uncompressed breast, using radiochromic films type XR-SP inserted at mid-plane in the phantom. The technique factors were 80 kVp (5.6 mm Al Half Value Layer), tube load in the range 23-100 mAs, for an air kerma at isocenter in the range 4.7-20 mGy, for a calculated MGD in the range 3.5-15 mGy for a 14 cm diameter breast of 50% glandularity. Results indicate that the dose decreases from the periphery to the center of the phantom, and that along a transverse profile, the relative dose variation Δ = ((edge-center)/center) is up to (25 ±4)% at a distance of 80 mm from the nipple. As for the relative dose variation along the phantom longitudinal axis, the maximum value at middle of the phantom measured is δ = ((nipple-chest wall)/chest wall) = -(15 ±4)%, indicating that the dose decreases from the chest wall toward the nipple. The values of the parameters Δ and δ depend also on the height of the X-ray tube focal spot with respect to the phantom vertex (nipple). Results are in rough agreement with similar previous determinations using thermoluminescence dosimeters.
Kelder, Johannes C; Cowie, Martin R; McDonagh, Theresa A; Hardman, Suzanna M C; Grobbee, Diederick E; Cost, Bernard; Hoes, Arno W
2011-06-01
Diagnosing early stages of heart failure with mild symptoms is difficult. B-type natriuretic peptide (BNP) has promising biochemical test characteristics, but its diagnostic yield on top of readily available diagnostic knowledge has not been sufficiently quantified in early stages of heart failure. To quantify the added diagnostic value of BNP for the diagnosis of heart failure in a population relevant to GPs and validate the findings in an independent primary care patient population. Individual patient data meta-analysis followed by external validation. The additional diagnostic yield of BNP above standard clinical information was compared with ECG and chest x-ray results. Derivation was performed on two existing datasets from Hillingdon (n=127) and Rotterdam (n=149) while the UK Natriuretic Peptide Study (n=306) served as validation dataset. Included were patients with suspected heart failure referred to a rapid-access diagnostic outpatient clinic. Case definition was according to the ESC guideline. Logistic regression was used to assess discrimination (with the c-statistic) and calibration. Of the 276 patients in the derivation set, 30.8% had heart failure. The clinical model (encompassing age, gender, known coronary artery disease, diabetes, orthopnoea, elevated jugular venous pressure, crackles, pitting oedema and S3 gallop) had a c-statistic of 0.79. Adding, respectively, chest x-ray results, ECG results or BNP to the clinical model increased the c-statistic to 0.84, 0.85 and 0.92. Neither ECG nor chest x-ray added significantly to the 'clinical plus BNP' model. All models had adequate calibration. The 'clinical plus BNP' diagnostic model performed well in an independent cohort with comparable inclusion criteria (c-statistic=0.91 and adequate calibration). Using separate cut-off values for 'ruling in' (typically implying referral for echocardiography) and for 'ruling out' heart failure--creating a grey zone--resulted in insufficient proportions of patients with a correct diagnosis. BNP has considerable diagnostic value in addition to signs and symptoms in patients suspected of heart failure in primary care. However, using BNP alone with the currently recommended cut-off levels is not sufficient to make a reliable diagnosis of heart failure.
[Etiology and diagnostic methods in vocal cord paralysis].
Jørgensen, Gita; Clausen, Eva Wiinstedt; Mantoni, Margit Y; Misciattelli, Lorenzo; Balle, Viggo
2003-02-10
The etiology of vocal cord paralysis (VCP) is varied. There is lack of consensus regarding the choice of investigations to be used in the evaluation of VCP. The aim of this study was to establish the etiology, assess the diagnostic methods used in the evaluation, and outline an algorithm for future evaluation of unilateral vocal cord paralysis (UVCP). Charts of all patients (n = 94) with the diagnostic code of VCP were reviewed, and reexaminations were performed of patients in whom no etiology was found after the initial symptoms. The etiology of UVCP was neoplasm in 34%, surgical trauma in 12%, and miscellaneous causes in 54%. The etiology of bilateral vocal cord paralysis (BVCP) was neoplasm in 24%, surgical trauma in 24%, and miscellaneous causes in 52%. The reexaminations did not reveal any cancer diseases in the patients concerned. The most effective diagnostic method was CT-scanning while the least effective was thyroid scanning. Because cancer is a common cause of VCP a thorough evaluation is necessary. For UVCP we recommend history and physical examination, X-ray of the chest, ultrasonography of the neck, and CT-scanning of the superior mediastinum. If these prove negative, panendoscopy should be performed. Workup of patients with idiopathic VCP should include examination, X-ray of the chest at 6-month intervals, and annual CT-scanning for two years.
Thoracoscopy: medical versus surgical—in the management of pleural diseases
2015-01-01
Diseases of the pleura continue to affect a large population of patients worldwide and in the United States. Pleural fluid analysis and accompanying imaging of the pleura including chest X-rays, chest computed tomography (CT) scan and chest ultrasonography are among the first steps in the management of pleural effusions. When further diagnostic or therapeutic work up is necessary, open thoracotomy and thoracoscopy come to mind. However, given the significant morbidity and mortality associated with open thoracotomy, and the advances in medicine and medical instruments, thoracoscopy has now become a routine procedure in the management of the disease of the chest including pleura. Debates about surgical vs. medical thoracoscopy (MT) are ongoing. In the following pages we review the literature and discuss the similarities and differences between the two procedures, as well as their indications, contraindications, complications and efficacy in the management of pleural diseases. PMID:26807282
Anand, Rahul J; Whelan, James F; Ferrada, Paula; Duane, Therese M; Malhotra, Ajai K; Aboutanos, Michel B; Ivatury, Rao R
2012-04-01
The factors contributing to the development of pneumothorax after removal of chest tube thoracostomy are not fully understood. We hypothesized that development of post pull pneumothorax (PPP) after chest tube removal would be significantly lower in those patients with thicker chest walls, due to the "protective" layer of adipose tissue. All patients on our trauma service who underwent chest tube thoracostomy from July 2010 to February 2011 were retrospectively reviewed. Patient age, mechanism of trauma, and chest Abbreviated Injury Scale score were analyzed. Thoracic CTs were reviewed to ascertain chest wall thickness (CW). Thickness was measured at the level of the nipple at the midaxillary line, as perpendicular distance between skin and pleural cavity. Chest X-ray reports from immediately prior and after chest tube removal were reviewed for interval development of PPP. Data are presented as average ± standard deviation. Ninety-one chest tubes were inserted into 81 patients. Patients who died before chest tube removal (n = 11), or those without thoracic CT scans (n = 13) were excluded. PPP occurred in 29.9 per cent of chest tube removals (20/67). When PPP was encountered, repeat chest tube was necessary in 20 per cent of cases (4/20). After univariate analysis, younger age, penetrating mechanism, and thin chest wall were found to be significant risk factors for development of PPP. Chest Abbreviated Injury Scale score was similar in both groups. Logistic regression showed only chest wall thickness to be an independent risk factor for development of PPP.
Paediatric x-ray radiation dose reduction and image quality analysis.
Martin, L; Ruddlesden, R; Makepeace, C; Robinson, L; Mistry, T; Starritt, H
2013-09-01
Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramanna, L.; Tashkin, D.P.; Taplin, G.V.
1975-11-01
Seventy subjects with either no, mild, or definite evidence of pulmonary abnormality on screening studies volunteered to have detailed pulmonary function tests (PFTs), respiratory questionnaires, physical examinations, and /sup 113m/indium aerosol-inhalation lung imaging performed. Also, 22 and 52 of these subjects underwent /sup 133/xenon ventilation and lung perfusion imaging with /sup 99m/technetium-labelled macroaggregated albumin, and 56 had chest x-ray examinations performed. Results of the radionuclide lung-imaging procedures were compared with those of conventional PFTs and other clinical diagnostic procedures used to identify chronic obstructive pulmonary disease (COPD). Abnormal radioaerosol patterns were found in 32 of 33 subjects with abnormal findingsmore » on PFTs, whereas results of PFTs were abnormal in only 32 of 46 subjects with abnormal aerosol deposition. Aerosol lung images were abnormal more frequently than respiratory questionnaire responses, findings on physical examination, chest x-ray films, and perfusion lung images and with approximately the same frequency as /sup 133/xenon ventilation scintiscans. These results suggest that radioaerosol lung imaging may be a more sensitive indicator of early COPD than other diagnostic procedures, including maximal midexpiratory flow rates, single-breath nitrogen washout, and closing volume. Further studies are required to determine the physiologic and pathologic significance of isolated aerosol lung-imaging abnormalities.« less
Pneumoconiosis after sericite inhalation.
Algranti, E; Handar, A M; Dumortier, P; Mendonça, E M C; Rodrigues, G L; Santos, A M A; Mauad, T; Dolhnikoff, M; De Vuyst, P; Saldiva, P H N; Bussacos, M A
2005-03-01
Between 1997 and 1999 three sericite plant workers in Parana, Brazil, were diagnosed with pneumoconiosis. To investigate and describe the radiological, clinical, and pathological changes in miners and millers exposed to sericite dust with mineralogical characteristics of inhaled dust. The working premises were visited to examine the sericite processing and to classify the jobs according to make qualitative evaluation. Respirable dust was collected and the amount of crystalline silica and particle size distribution were measured. Forty four workers were examined by a standard questionnaire for respiratory symptoms, spirometry, and chest x ray. Material from an open lung biopsy was reviewed for histopathological and mineralogical analysis, together with sericite samples from the work site to compare the mineral characteristics in lung lesions and work area. Respirable dust contained 4.5-10.0% crystalline silica. Particle size distribution showed a heavy burden of very fine particles (23-55%) with a mean diameter of <0.5 microm. Mean age of sericite miners was 41.0 (11.9) and mean number of years of exposure was 13.5 (10.1). In 52.3% of workers (23/44), chest radiographs presented a median category of 1/0 or above, and 18.2% (8/44) had a reduced FEV1. There was a significant association between exposure indices and x ray category. Histological studies of the lung biopsy showed lesions compatible with mixed dust fibrosis with no silicotic nodules. x Ray diffraction analysis of the lung dust residue and the bulk samples collected from work area showed similar mineralogical characteristics. Muscovite and kaolinite were the major mineral particle inclusions in the lung. Exposure to fine sericite particles is associated with the development of functional and radiological changes in workers inducing mixed dust lesions, which are distinct histologically from silicosis.
Rohde, Max; Nielsen, Anne L; Johansen, Jørgen; Sørensen, Jens A; Nguyen, Nina; Diaz, Anabel; Nielsen, Mie K; Asmussen, Jon T; Christiansen, Janus M; Gerke, Oke; Thomassen, Anders; Alavi, Abass; Høilund-Carlsen, Poul Flemming; Godballe, Christian
2017-12-01
The purpose of this study was to determine the detection rate of distant metastasis and synchronous cancer, comparing clinically used imaging strategies based on chest x-ray + head and neck MRI (CXR/MRI) and chest CT + head and neck MRI (CHCT/MRI) with 18 F-FDG PET/CT upfront in the diagnostic workup of patients with oral, pharyngeal, or laryngeal cancer. Methods: This was a prospective cohort study based on paired data. Consecutive patients with histologically verified primary head and squamous cell carcinoma at Odense University Hospital from September 2013 to March 2016 were considered for the study. Included patients underwent CXR/MRI and CHCT/MRI as well as PET/CT on the same day and before biopsy. Scans were read masked by separate teams of experienced nuclear physicians or radiologists. The true detection rate of distant metastasis and synchronous cancer was assessed for CXR/MRI, CHCT/MRI, and PET/CT. Results: A total of 307 patients were included. CXR/MRI correctly detected 3 (1%) patients with distant metastasis, CHCT/MRI detected 11 (4%) patients, and PET/CT detected 18 (6%) patients. The absolute differences of 5% and 2%, respectively, were statistically significant in favor of PET/CT. Also, PET/CT correctly detected 25 (8%) synchronous cancers, which was significantly more than CXR/MRI (3 patients, 1%) and CHCT/MRI (6 patients, 2%). The true detection rate of distant metastasis or synchronous cancer with PET/CT was 13% (40 patients), which was significantly higher than 2% (6 patients) for CXR/MRI and 6% (17 patients) for CHCT/MRI. Conclusion: A clinical imaging strategy based on PET/CT demonstrated a significantly higher detection rate of distant metastasis or synchronous cancer than strategies in current clinical imaging guidelines, of which European ones primarily recommend CXR/MRI, whereas U.S. guidelines preferably point to CHCT/MRI in patients with head and neck squamous cell carcinoma. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Radiation safety education reduces the incidence of adult fingers on neonatal chest radiographs.
Sahota, N; Burbridge, B E; Duncan, M D
2014-06-01
A previous audit revealed a high frequency of adult fingers visualised on neonatal intensive care unit (NICU) chest radiographs-representing an example of inappropriate occupational radiation exposure. Radiation safety education was provided to staff and we hypothesised that the education would reduce the frequency of adult fingers visualised on NICU chest radiographs. Two cross-sectional samples taken before and after the administration of the education were compared. We examined fingers visualised directly in the beam, fingers in the direct beam but eliminated by technologists editing the image, and fingers under the cones of the portable x-ray machine. There was a 46.2% reduction in fingers directly in the beam, 50.0% reduction in fingers directly in the beam but cropped out, and 68.4% reduction in fingers in the coned area. There was a 57.1% overall reduction in adult fingers visualised, which was statistically significant (Z value - 7.48, P < 0.0001). This study supports radiation safety education in minimising inappropriate occupational radiation exposure.
Hypersensitivity pneumonitis due to flavocoxid: are corticosteroids necessary?
Panduranga, Veena; Atienza, Jonessa; Kumar, Anupam; Metersky, Mark L
2013-02-01
Hypersensitivity pneumonitis (HP) is a rare adverse event with flavocoxid (Limbrel) use. Patients present with nonspecific symptoms after exposure to an inciting agent. A 42-year-old female presented with worsening dyspnea on exertion and pleuritic midsternal chest pain. Her symptoms failed to abate with outpatient azithromycin for a diagnosis of community-acquired pneumonia. She was seen again at the emergency department (ED) due to symptom progression and exertional hypoxia. Chest reoentgenogram (x-ray) and computed tomography (CT) chest revealed bilateral infiltrates. Her history was significant for initiation of flavocoxid (Limbrel) two weeks prior, and a diagnosis of hypersensitivity pneumonitis was made. Once flavocoxid was discontinued, symptoms and radiologic studies improved without requiring biopsy or steroids. Hypersensitivity pneumonitis is associated with many pharmacological agents and is challenging to diagnose, given nonspecific symptoms and radiologic findings. In the absence of specific indications to use corticosteroids, symptoms of HP might resolve with cessation of the offending agent, as proven by this case.
Preservation of normal lung regions in the adult respiratory distress syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maunder, R.J.; Shuman, W.P.; McHugh, J.W.
1986-05-09
In this report, the authors challenge the commonly held assumption that the adult respiratory distress syndrome (ARDS) is a homogeneous process associated with generalized and relatively uniform damage to the alveolar capillary membrane. They studied 13 patients with ARDS, comparing the pulmonary parenchymal changes seen by standard bedside chest roentgenograms with those seen by computed tomography of the chest. Three patients demonstrated generalized lung involvement by both radiologic techniques. In another eight patients, despite the appearance of generalized involvement on the standard chest x-ray film, the computed tomographic scans showed patchy infiltrates interspersed with areas of normal-appearing lung. Two patientsmore » showed patchy involvement by both techniques. The fact that ARDS spares some regions of lung parenchyma is useful knowledge in understanding the gas-exchange abnormalities of ARDS, the variable responsiveness to positive end-expiratory pressure, and the occurrence of oxygen toxicity. The problem of regional inhomogeneity should also be kept in mind when interpreting lung biopsy specimens or bronchoalveolar lavage fluid in patients with ARDS.« less
[Mediastinal Pancreatic Pseudocyst with Pancreatic Pleural Effusion].
Sasajima, Motoko; Kawai, Hideki; Suzuki, Yohei; Saito, Yoshitaro; Eto, Takeshi
2017-06-01
A 72-year-old man with chronic alcohol related pancreatitis was admitted for dyspnea and pain at the upper body. Chest X-ray showed right massive pleural effusion. Chest and abdominal contrast enhanced thin slice computed tomography revealed the route from the pancreatic head reaching the right thoracic cavity via the esophagus hiatus and the communication between the cystic lesion and main pancreatic duct. We drained the pleural effusion that showed abnormally high amylase activity. We diagnosed his illness as mediastinal pancreatic pseudocyst with pancreatic pleural effusion. Endoscopic Nasopancreatic Drainage catheter was placed in the main pancreatic duct, and the pleural effusion disappeared.
Diagnostic cardiology: Noninvasive imaging techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Come, P.C.
1985-01-01
This book contains 23 chapters. Some of the chapter titles are: The chest x-ray and cardiac series; Computed tomographic scanning of the heart, coronary arteries, and great vessels; Digital subtraction angiography in the assessment of cardiovascular disease; Magnetic resonance: technique and cardiac applications; Basics of radiation physics and instrumentation; and Nuclear imaging: the assessment of cardiac performance.
42 CFR 37.4 - Plans for chest roentgenographic examinations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... covered by the plan; (4) The name and location of the approved X-ray facility or facilities, and the... approval as the originally approved plan. (e) The operator must promptly display in a visible location on... NIOSH. The proposed plan or change in plan must remain posted in a visible location on the bulletin...
20 CFR 718.102 - Chest roentgenograms (X-rays).
Code of Federal Regulations, 2010 CFR
2010-04-01
... examining physician along with the film. The report shall specify the name and qualifications of the person who took the film and the name and qualifications of the physician interpreting the film. If the physician interpreting the film is a Board-certified or Board-eligible radiologist or a certified “B” reader...
Cystic Fibrosis Chest X-Ray Findings: A Teaching Analog
2008-07-01
lung volume. There are five specific types of atelectasis: obstructive, compressive, cicatrization , post-operative and adhesive. Obstructive...commonly, a pleural lesion or mass can cause impact on the neighboring lung tissue causing compression of the alveoli in that area. Cicatrization ...Lymphoma Atelectasis Obstructive Compressive Pneumothorax Pleural Effusion Pleural Lesion Cicatrization Radiation Severe Pneumonia Adhesive
Cunha, Burke A; Syed, Uzma; Mikail, Nardeen
2012-01-01
Depending on the community-acquired pneumonia (CAP) pathogen, host factors, and immune status, CAPs resolve on chest x-rays at different rates. CAPs that resolve more slowly than expected, or not at all, are termed "slowly or non-resolving CAPs." In contrast, recurrent CAPs may be due to host defense defects (eg, multiple myelomas) or post-obstructive bronchogenic carcinomas. There are a variety of noninfectious disorders that may mimic CAPs on chest x-ray: alveolar hemorrhage, pulmonary drug reactions, radiation pneumonitis, Wegener's granulomatosis, bronchiolitis obliterans organizing pneumonia, bronchogenic carcinomas, and lymphomas. Noninfectious mimics of recurrent CAPs include congestive heart failure, pulmonary emboli, infarctions, sarcoidosis, and systemic lupus erythematosus pneumonitis. We present the case of a middle-aged man who presented with recurrent right middle lobe and right lower lobe CAPs. Diagnostic bronchoscopy showed no bronchial obstruction, but open lung biopsy showed bronchoalveolar carcinoma (well-differentiated adenocarcinoma). Bronchoalveolar carcinomas presenting as post-obstructive or recurrent CAPs are rare because the spread is along tissue planes and not endobronchially. The case described demonstrates a rare cause of bronchogenic carcinoma mimicking recurrent CAP. Copyright © 2012 Elsevier Inc. All rights reserved.
PULMONARY CYSTIC ECHINOCOCCOSIS
Santivanez, Saul; Garcia, Hector H.
2012-01-01
Pulmonary cystic echinococosis, a zoonosis caused by the larvae of the dog tapeworm Echinococcus granulosus, is considered as a major public health problem in those countries where dogs are used to care for large herds because of the incapacitating effects produced in affected population. The ratio lung:liver involvement is higher in children than in adults. A higher proportion of lung cases are discovered incidentally on a routine x-ray evaluation; the majority of infected people remain asymptomatic until the cyst enlarges sufficiently to cause symptoms. The majority of symptoms are caused by mass effect from the cyst volume; the presence of complications caused by cysts broke changes the clinical presentation; the principal complication is cyst rupture, producing cough, chest pain, hemoptysis, or vomica. Diagnosis is obtained by imaging evaluation (Chest X-ray or CT scan), supported by serology in the majority of cases. Surgery is the main therapeutic approach, having as principal objective, the removal of the parasite, preventing intraoperative dissemination; the use of pre surgical chemotherapy reduces the chances of seeding and recurrence; treatment using benzimidazoles is the preferred treatment when surgery is not available, or complete removal is not feasible PMID:20216420
[Tuberculosis in the Royal Norwegian Navy at the time of the Second World War].
Ongre, Aksel; Sommerfelt-Pettersen, Jan
2008-12-18
Tuberculosis became a great problem in the Royal Norwegian Navy during the first years of the Second World War (when it operated in allied services mainly from the UK); with the highest incidence (9.6 per 1 000) during the first half of 1943. Main reasons were insufficient medical examination of recruits, crowded living conditions on board (favoured the contagion) and the physical and psychological pressure during sea operations, which may have reduced the immune defence. Prophylactic measures in terms of tuberculin testing of all personnel, chest X-rays of the positives, vaccination of the negatives, environment investigation when disease was discovered, and isolation of those infected, gave control from the second half of 1943 and onwards. The article also mentions treatment, repatriation and the incidence of tuberculosis in the Norwegian Navy before and after the war as well as in the Royal Canadian Naval Services (where the incidence was low) during the war. Today, the tuberculosis situation in Norway is so favourable that routine chest X-ray of the recruits is no longer performed in the armed forces.
Vogl, T J; Martin, S; Brodt, H R; Keppler, O; Zacharowski, K; Wolf, T
2015-09-01
Since the Ebola virus was discovered in 1976, the largest outbreak to date is the ongoing epidemic in West Africa based on the number of cases. The number of infected people is high among aid workers, some of whom have been treated at intensive care units in specialized centers in Europe and the USA. A 38-year-old patient who got infected with the Ebola virus was treated in a special isolation ward at the Frankfurt University Hospital from 10/3/14 to 11/19/14. During intensive care of the patient, X-rays were essential for control of the cardiopulmonary system and for follow-up. Special guidelines had to be considered for performing X-rays due to the risk of transmitting the virus. These are presented and discussed in the following. Chest radiographs are essential in the intensive care monitoring of Ebola patients. Chest radiographs help to assess the extent of pulmonary edema and capillary leak syndrome. With careful observance of hygiene guidelines, he risk of transmission can be virtually eliminated. © Georg Thieme Verlag KG Stuttgart · New York.
Anavi, Yaron; Kogan, Ilya; Gelbart, Elad; Geva, Ofer; Greenspan, Hayit
2015-08-01
In this work various approaches are investigated for X-ray image retrieval and specifically chest pathology retrieval. Given a query image taken from a data set of 443 images, the objective is to rank images according to similarity. Different features, including binary features, texture features, and deep learning (CNN) features are examined. In addition, two approaches are investigated for the retrieval task. One approach is based on the distance of image descriptors using the above features (hereon termed the "descriptor"-based approach); the second approach ("classification"-based approach) is based on a probability descriptor, generated by a pair-wise classification of each two classes (pathologies) and their decision values using an SVM classifier. Best results are achieved using deep learning features in a classification scheme.
Clément, R; Fornes, P; Lecomte, D
2001-02-17
Ingestion of illicit drug packages is a well known method for transportation. These packages are prone to rupture causing overdose. The body packer syndrome may be overlooked in medical practice as illustrated by the following case report. A 19-year old male had convulsions followed by cardiac arrest during a flight. He was resuscitated in the plane, but he died a few hours after admission in intensive care unit. Chest and abdominal X-rays were considered normal. Cocaïne métabolites were found in his urine. The death was considered suspicious. X-rays performed before medicolegal autopsy showed numerous packages in his digestive tract. Thirty-six packages were found in the stomach and intestine. Two were ruptured in the stomach. The cause of death was cocaïne overdose caused by package rupture. The packages are usually visible on an standard abdomen X-ray. The drug is often wrapped in latex membranes or condoms. The air is trapped between the condoms by the nodes, forming two crescents visible on the X-ray. Surgery is preferred to laxatives when the packages are fragile with a high risk of rupture.
Chest x-ray as a screening tool for blunt thoracic trauma in children.
Yanchar, Natalie L; Woo, Kenneth; Brennan, Maureen; Palmer, Cameron S; Zs Ee, Michael; Sweeney, Brian; Crameri, Joe
2013-10-01
With the increasing use of thoracic computed tomography (CT) to screen for injuries in pediatric blunt thoracic trauma (BTT), we determined whether chest x-ray (CXR) and other clinical and epidemiologic variables could be used to predict significant thoracic injuries, to inform the selective use of CT in pediatric BTT. We further queried if these were discrepant from factors associated with the decision to obtain a thoracic CT. This retrospective cohort study included cases of BTT from three Level I pediatric trauma centers between April 1999 and March 2008. Pre-CT epidemiologic, clinical, and radiologic variables associated with CT findings of any thoracic injury or a significant thoracic injury as well as the decision to obtain a thoracic CT were determined using logistic regression. Of 425 patients, 40% patients had a significant thoracic injury, 49% had nonsignificant thoracic injury, and 11% had no thoracic injury at all. Presence of hydrothorax and/or pneumothorax on CXR significantly increased the likelihood of significant chest injury visualized by CT (adjusted odds ratio 10.8; 95% confidence interval, 6.5-18), as did the presence of isolated subcutaneous emphysema (adjusted odds ratio, 19.8; 95% confidence interval, 2.3-168). Although a normal CXR finding was not statistically associated with a reduced risk of significant thoracic injury, 8 of the 9 cases with normal CXR findings and significant injuries involved occult pneumothoraces or hemothoraces not requiring intervention. Converse to features suggesting increased risk of significant injury, the decision to obtain a thoracic CT was only associated with later period in the study and obtaining a CT scan of another body region. CXR can be used to screen for significant thoracic injuries and direct the selective use of thoracic CT in pediatric BTT. Prospective studies are needed to validate these findings and develop guidelines that include CXR to define indications for thoracic CT in pediatric BTT. Prognostic study, level III.
Cost-Effectiveness Analysis of Diagnostic Options for Pneumocystis Pneumonia (PCP)
Harris, Julie R.; Marston, Barbara J.; Sangrujee, Nalinee; DuPlessis, Desiree; Park, Benjamin
2011-01-01
Background Diagnosis of Pneumocystis jirovecii pneumonia (PCP) is challenging, particularly in developing countries. Highly sensitive diagnostic methods are costly, while less expensive methods often lack sensitivity or specificity. Cost-effectiveness comparisons of the various diagnostic options have not been presented. Methods and Findings We compared cost-effectiveness, as measured by cost per life-years gained and proportion of patients successfully diagnosed and treated, of 33 PCP diagnostic options, involving combinations of specimen collection methods [oral washes, induced and expectorated sputum, and bronchoalveolar lavage (BAL)] and laboratory diagnostic procedures [various staining procedures or polymerase chain reactions (PCR)], or clinical diagnosis with chest x-ray alone. Our analyses were conducted from the perspective of the government payer among ambulatory, HIV-infected patients with symptoms of pneumonia presenting to HIV clinics and hospitals in South Africa. Costing data were obtained from the National Institutes of Communicable Diseases in South Africa. At 50% disease prevalence, diagnostic procedures involving expectorated sputum with any PCR method, or induced sputum with nested or real-time PCR, were all highly cost-effective, successfully treating 77–90% of patients at $26–51 per life-year gained. Procedures using BAL specimens were significantly more expensive without added benefit, successfully treating 68–90% of patients at costs of $189–232 per life-year gained. A relatively cost-effective diagnostic procedure that did not require PCR was Toluidine Blue O staining of induced sputum ($25 per life-year gained, successfully treating 68% of patients). Diagnosis using chest x-rays alone resulted in successful treatment of 77% of patients, though cost-effectiveness was reduced ($109 per life-year gained) compared with several molecular diagnostic options. Conclusions For diagnosis of PCP, use of PCR technologies, when combined with less-invasive patient specimens such as expectorated or induced sputum, represent more cost-effective options than any diagnostic procedure using BAL, or chest x-ray alone. PMID:21858013
Minns, F C; Mhuineachain, A Ni; van Beek, E J R; Ritchie, G; Hill, A; Murchison, J T
2015-09-01
To review, phenotype and assess potential prognostic value of initial chest X-ray findings in patients with H1N1 influenza during seasonal outbreaks of 2009 and 2010, in comparison with non-H1N1, community acquired pneumonia (CAP). We retrospectively identified 72 patients admitted to hospital with pneumonia during the seasons of 2009 and 2010. H1N1 cases were confirmed by virology PCR. Presenting chest X-rays were jointly read by 2 radiologists, who were 'blinded' to further patient details and divided into 6 zones. Total number of opacified zones, the pattern and distribution of changes and length of hospital stay were recorded. Patients with H1N1 demonstrated more opacified zones (mean of 2.9 compared with 2.0; p=0.006), which were bilateral in two-thirds compared with a quarter of those with non-H1N1 CAP (p=0.001). H1N1 radiographs were more likely to be 'patchy' versus 'confluent' changes of non-H1N1 CAP (p=0.03) and more often demonstrated peripheral distribution (p=0.01). H1N1 patients tended to stay in hospital longer (not significant; p=0.08). A positive correlation existed between number of affected zones and length of inpatient stay, which was statistically significant for the cohorts combined (p=0.02). The findings were the same for the two evaluated seasons. H1N1 patients demonstrated more extensive disease, which was more likely bilateral, 'patchy', and peripheral in distribution. With increasing global cases of H1N1, knowledge of the typical findings of the H1N1 presenting chest X-ray may assist with early triage of patients, particularly where rapid viral testing is not available. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Anatomy-based transmission factors for technique optimization in portable chest x-ray
NASA Astrophysics Data System (ADS)
Liptak, Christopher L.; Tovey, Deborah; Segars, William P.; Dong, Frank D.; Li, Xiang
2015-03-01
Portable x-ray examinations often account for a large percentage of all radiographic examinations. Currently, portable examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of various thicknesses are often used to estimate x-ray transmission for patients of various body thicknesses. This approach, while simple, does not account for patient anatomy, tissue heterogeneity, and the attenuation properties of the human body. To better account for these factors, in this work, we determined x-ray transmission factors using computational patient models that are anatomically realistic. A Monte Carlo program was developed to model a portable x-ray system. Detailed modeling was done of the x-ray spectrum, detector positioning, collimation, and source-to-detector distance. Simulations were performed using 18 computational patient models from the extended cardiac-torso (XCAT) family (9 males, 9 females; age range: 2-58 years; weight range: 12-117 kg). The ratio of air kerma at the detector with and without a patient model was calculated as the transmission factor. Our study showed that the transmission factor decreased exponentially with increasing patient thickness. For the range of patient thicknesses examined (12-28 cm), the transmission factor ranged from approximately 21% to 1.9% when the air kerma used in the calculation represented an average over the entire imaging field of view. The transmission factor ranged from approximately 21% to 3.6% when the air kerma used in the calculation represented the average signals from two discrete AEC cells behind the lung fields. These exponential relationships may be used to optimize imaging techniques for patients of various body thicknesses to aid in the design of clinical technique charts.
Idris, Baig M; Hefny, Ashraf F
2016-01-01
Pneumothorax is the most common potentially life-threatening blunt chest injury. The management of pneumothorax depends upon the etiology, its size and hemodynamic stability of the patient. Most clinicians agree that chest drainage is essential for the management of traumatic large pneumothorax. Herein, we present a case of large pneumothorax in blunt chest trauma patient that resolved spontaneously without a chest drain. A 63- year- old man presented to the Emergency Department complaining of left lateral chest pain due to a fall on his chest at home. On examination, he was hemodynamically stable. An urgent chest X-ray showed evidence of left sided pneumothorax. CT scan of the chest showed pneumothorax of more than 30% of the left hemithorax (around 600ml of air) with multiple left ribs fracture. Patient refused tube thoracostomy and was admitted to surgical department for close observation. The patient was managed conservatively without chest tube insertion. A repeat CT scan of the chest has shown complete resolution of the pneumothorax. The clinical spectrum of pneumothorax varies from asymptomatic to life threatening tension pneumothorax. In stable patients, conservative management can be safe and effective for small pneumothorax. To the best of our knowledge, this is the second reported case in the English literature with large pneumothorax which resolved spontaneously without chest drain. Blunt traumatic large pneumothorax in a clinically stable patient can be managed conservatively. Current recommendations for tube placement may need to be reevaluated. This may reduce morbidity associated with chest tube thoracostomy. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Divrik Gökçe, Senem; Coşkun, Melek
2012-01-01
Objective Imaging methods that use ionizing radiation have been more frequent in various medical fields with advances in imaging technology. The aim of our study was to make residents be aware of the radiation dose they are subjected to when they conduct radiological imaging methods, and of cancer risk. Materials and Methods A total of 364 residents participated in this descriptive study which was conducted during the period between October, 2008 and January, 2009. The questionnaires were completed under strict control on a one-to-one basis from each department. A χ2-test was used for the evaluation of data obtained. Results Only 7% of residents correctly answered to the question about the ionizing radiation dose of a posteroanterior (PA) chest X-ray. The question asking about the equivalent number of PA chest X-rays to the ionizing dose of a brain CT was answered correctly by 24% of residents; the same question regarding abdominal CT was answered correctly by 16% of residents, thorax CT by 16%, thyroid scintigraphy by 15%, intravenous pyelography by 9%, and lumbar spine radiography by 2%. The risk of developing a cancer throughout lifetime by a brain and abdominal CT were 33% and 28%, respectively. Conclusion Radiologic residents should have updated knowledge about radiation dose content and attendant cancer risks of various radiological imaging methods during both basic medical training period and following practice period. PMID:22438688
Gastric volvulus through morgagni hernia: an easily overlooked emergency.
Sonthalia, Nikhil; Ray, Sayantan; Khanra, Dibbendhu; Saha, Avishek; Maitra, Subhasis; Saha, Manjari; Talukdar, Arunansu
2013-06-01
Intractable vomiting in an elderly patient is an emergency condition requiring prompt diagnosis and intervention. Acute gastric outlet obstruction due to gastric volvulus through Morgagni-type diaphragmatic hernia is an exceedingly rare cause of this nonspecific complaint. Our aim was to highlight that Morgagni hernia, although rare in adults, should be suspected in the appropriate clinical setting, and that a clue toward diagnosis often comes from routine chest and abdominal x-ray studies. In addition, we emphasize the atypical radiological findings and importance of emergency surgical intervention in such a case. We describe the case of a 78-year-old woman who presented to the Emergency Department with a 4-day history of intractable vomiting, and with no definitive clue to the diagnosis on examination. Her routine chest and abdomen x-ray studies suggested abnormal air-fluid level at right hemithorax, which prompted a computed tomography (CT) scan of the abdomen and an upper gastrointestinal contrast study. Gastric volvulus through a foramen of Morgagni was diagnosed and transthoracic reduction of the contents was performed, along with repair of the defect. A symptomatic Morgagni hernia in adults, although rare, can present with a variety of symptoms ranging from nonspecific complaints of bloating and indigestion to the more severe complaint of intestinal obstruction. Gastric volvulus and obstructive features are less frequently reported as acute complications of these hernias, which need early identification and intervention. Copyright © 2013 Elsevier Inc. All rights reserved.
Szigeti, Krisztián; Szabó, Tibor; Korom, Csaba; Czibak, Ilona; Horváth, Ildikó; Veres, Dániel S; Gyöngyi, Zoltán; Karlinger, Kinga; Bergmann, Ralf; Pócsik, Márta; Budán, Ferenc; Máthé, Domokos
2016-02-11
Lung diseases (resulting from air pollution) require a widely accessible method for risk estimation and early diagnosis to ensure proper and responsive treatment. Radiomics-based fractal dimension analysis of X-ray computed tomography attenuation patterns in chest voxels of mice exposed to different air polluting agents was performed to model early stages of disease and establish differential diagnosis. To model different types of air pollution, BALBc/ByJ mouse groups were exposed to cigarette smoke combined with ozone, sulphur dioxide gas and a control group was established. Two weeks after exposure, the frequency distributions of image voxel attenuation data were evaluated. Specific cut-off ranges were defined to group voxels by attenuation. Cut-off ranges were binarized and their spatial pattern was associated with calculated fractal dimension, then abstracted by the fractal dimension -- cut-off range mathematical function. Nonparametric Kruskal-Wallis (KW) and Mann-Whitney post hoc (MWph) tests were used. Each cut-off range versus fractal dimension function plot was found to contain two distinctive Gaussian curves. The ratios of the Gaussian curve parameters are considerably significant and are statistically distinguishable within the three exposure groups. A new radiomics evaluation method was established based on analysis of the fractal dimension of chest X-ray computed tomography data segments. The specific attenuation patterns calculated utilizing our method may diagnose and monitor certain lung diseases, such as chronic obstructive pulmonary disease (COPD), asthma, tuberculosis or lung carcinomas.
Clinical validation of a medical grade color monitor for chest radiology
NASA Astrophysics Data System (ADS)
Jacobs, J.; Zanca, F.; Verschakelen, J.; Marchal, G.; Bosmans, H.
2009-02-01
Until recently, the specifications of medical grade monochrome LCD monitors outperformed those of color LCD monitors. New generations of color LCD monitors, however, show specifications that are in many respects similar to those of monochrome monitors typically used in diagnostic workstations. The aim of present study was to evaluate the impact of different medical grade monitors in terms of detection of simulated lung nodules in chest x-ray images. Specifically, we wanted to compare a new medical grade color monitor (Barco Coronis 6MP color) to a medical grade grayscale monitor (Barco Coronis 3MP monochrome) and a consumer color monitor (Philips 200VW 1.7MP color) by means of an observer performance experiment. Using the free-response acquisition data paradigm, seven radiologists were asked to detect and locate lung nodules (170 in total), simulated in half of the 200 chest X-ray images used in the experiment. The jackknife free-response receiver operating characteristic (JAFROC) analysis of the data showed a statistically significant difference between at least two monitors, F-value=3.77 and p-value =0.0481. The different Figure of Merit values were 0.727, 0.723 and 0.697 for the new color LCD monitor, the medical grade monitor and the consumer color monitor respectively. There was no difference between the needed reading times but there was a difference between the mean calculated Euclidian distances between the position marked by the observers and the center of the simulated nodule, indicating a better accuracy with both medical grade monitors. Present data suggests that the new generation of medical grade color monitors could be used as diagnostic workstations.
Keveson, Benjamin; Clouser, Ryan D; Hamlin, Mark P; Stevens, Pamela; Stinnett-Donnelly, Justin M; Allen, Gilman B
2017-01-01
Chest X-rays (CXRs) are traditionally obtained daily in all patients on invasive mechanical ventilation (IMV) in the intensive care unit (ICU). We sought to reduce overutilisation of CXRs obtained in the ICU, using a multifaceted intervention to eliminate automated daily studies. We first educated ICU staff about the low diagnostic yield of automated daily CXRs, then removed the 'daily' option from the electronic health records-based ordering system, and added a query (CXR indicated or not indicated) to the ICU daily rounding checklist to prompt a CXR order when clinically warranted. We built a report from billing codes, focusing on all CXRs obtained on IMV census days in the medical (MICU) and surgical (SICU) ICUs, excluding the day of admission and days that a procedure warranting CXR was performed. This generated the number of CXRs obtained every 1000 'included' ventilator days (IVDs), the latter defined as not having an 'absolute' clinical indication for CXR. The average monthly number of CXRs on an IVD decreased from 919±90 (95% CI 877 to 963) to 330±87 (95% CI 295 to 354) per 1000 IVDs in the MICU, and from 995±69 (95% CI 947 to 1055) to 649±133 (95% CI 593 to 697) in the SICU. This yielded an estimated 1830 to 2066 CXRs avoided over 2 years and an estimated annual savings of $191 600 to $224 200. There was no increase in reported adverse events. ICUs can safely transition to a higher value strategy of indication-based chest imaging by educating staff, eliminating the 'daily' order option and adding a simplified prompt to avoid missing clinically indicated CXRs.
The beam stop array method to measure object scatter in digital breast tomosynthesis
NASA Astrophysics Data System (ADS)
Lee, Haeng-hwa; Kim, Ye-seul; Park, Hye-Suk; Kim, Hee-Joung; Choi, Jae-Gu; Choi, Young-Wook
2014-03-01
Scattered radiation is inevitably generated in the object. The distribution of the scattered radiation is influenced by object thickness, filed size, object-to-detector distance, and primary energy. One of the investigations to measure scatter intensities involves measuring the signal detected under the shadow of the lead discs of a beam-stop array (BSA). The measured scatter by BSA includes not only the scattered radiation within the object (object scatter), but also the external scatter source. The components of external scatter source include the X-ray tube, detector, collimator, x-ray filter, and BSA. Excluding background scattered radiation can be applied to different scanner geometry by simple parameter adjustments without prior knowledge of the scanned object. In this study, a method using BSA to differentiate scatter in phantom (object scatter) from external background was used. Furthermore, this method was applied to BSA algorithm to correct the object scatter. In order to confirm background scattered radiation, we obtained the scatter profiles and scatter fraction (SF) profiles in the directions perpendicular to the chest wall edge (CWE) with and without scattering material. The scatter profiles with and without the scattering material were similar in the region between 127 mm and 228 mm from chest wall. This result indicated that the measured scatter by BSA included background scatter. Moreover, the BSA algorithm with the proposed method could correct the object scatter because the total radiation profiles of object scatter correction corresponded to original image in the region between 127 mm and 228 mm from chest wall. As a result, the BSA method to measure object scatter could be used to remove background scatter. This method could apply for different scanner geometry after background scatter correction. In conclusion, the BSA algorithm with the proposed method is effective to correct object scatter.
Muyoyeta, Monde; Maduskar, Pragnya; Moyo, Maureen; Kasese, Nkatya; Milimo, Deborah; Spooner, Rosanna; Kapata, Nathan; Hogeweg, Laurens; van Ginneken, Bram; Ayles, Helen
2014-01-01
To determine the sensitivity and specificity of a Computer Aided Diagnosis (CAD) program for scoring chest x-rays (CXRs) of presumptive tuberculosis (TB) patients compared to Xpert MTB/RIF (Xpert). Consecutive presumptive TB patients with a cough of any duration were offered digital CXR, and opt out HIV testing. CXRs were electronically scored as normal (CAD score ≤ 60) or abnormal (CAD score > 60) using a CAD program. All patients regardless of CAD score were requested to submit a spot sputum sample for testing with Xpert and a spot and morning sample for testing with LED Fluorescence Microscopy-(FM). Of 350 patients with evaluable data, 291 (83.1%) had an abnormal CXR score by CAD. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CXR compared to Xpert were 100% (95%CI 96.2-100), 23.2% (95%CI 18.2-28.9), 33.0% (95%CI 27.6-38.7) and 100% (95% 93.9-100), respectively. The area under the receiver operator curve (AUC) for CAD was 0.71 (95%CI 0.66-0.77). CXR abnormality correlated with smear grade (r = 0.30, p<0.0001) and with Xpert CT(r = 0.37, p<0.0001). To our knowledge this is the first time that a CAD program for TB has been successfully tested in a real world setting. The study shows that the CAD program had high sensitivity but low specificity and PPV. The use of CAD with digital CXR has the potential to increase the use and availability of chest radiography in screening for TB where trained human resources are scarce.
NASA Astrophysics Data System (ADS)
Pietrzyk, Mariusz W.; McEntee, Mark; Evanoff, Michael G.; Brennan, Patrick C.
2012-02-01
Aim: This study evaluates the assumption that global impression is created based on low spatial frequency components of posterior-anterior chest radiographs. Background: Expert radiologists precisely and rapidly allocate visual attention on pulmonary nodules chest radiographs. Moreover, the most frequent accurate decisions are produced in the shortest viewing time, thus, the first hundred milliseconds of image perception seems be crucial for correct interpretation. Medical image perception model assumes that during holistic analysis experts extract information based on low spatial frequency (SF) components and creates a mental map of suspicious location for further inspection. The global impression results in flagged regions for detailed inspection with foveal vision. Method: Nine chest experts and nine non-chest radiologists viewed two sets of randomly ordered chest radiographs under 2 timing conditions: (1) 300ms; (2) free search in unlimited time. The same radiographic cases of 25 normal and 25 abnormal digitalized chest films constituted two image sets: low-pass filtered and unfiltered. Subjects were asked to detect nodules and rank confidence level. MRMC ROC DBM analyses were conducted. Results: Experts had improved ROC AUC while high SF components are displayed (p=0.03) or while low SF components were viewed under unlimited time (p=0.02) compared with low SF 300mSec viewings. In contrast, non-chest radiologists showed no significant changes when high SF are displayed under flash conditions compared with free search or while low SF components were viewed under unlimited time compared with flash. Conclusion: The current medical image perception model accurately predicted performance for non-chest radiologists, however chest experts appear to benefit from high SF features during the global impression.
2012-01-01
Background X-rays are known to interact with metallic nanoparticles, producing photoelectric species as radiosensitizing effects, and have been exploited in vivo mainly with gold nanoparticles. The purpose of this study was to investigate the potential of sensitizing effect of iron oxide nanoparticles for photon activated therapy. Methods X-rays photon activated therapy (PAT) was studied by treating CT26 tumor cells and CT26 tumor-bearing mice loaded with 13-nm diameter FeO NP, and irradiating them at 7.1 keV near the Fe K-edge using synchrotron x-rays radiation. Survival of cells was determined by MTT assay, and tumor regression assay was performed for in vivo model experiment. The results of PAT treated groups were compared with x-rays alone control groups. Results A more significant reduction in viability and damage was observed in the FeO NP-treated irradiated cells, compared to the radiation alone group (p < 0.04). Injection of FeO NP (100 mg/kg) 30 min prior to irradiation elevated the tumor concentration of magnetite to 40 μg of Fe/g tissue, with a tumor-to-muscle ratio of 17.4. The group receiving FeO NP and radiation of 10 Gy showed 80% complete tumor regression (CTR) after 15–35 days and relapse-free survival for up to 6 months, compared to the control group, which showed growth retardation, resulting in 80% fatality. The group receiving radiation of 40 Gy showed 100% CTR in all cases irrespective of the presence of FeO NP, but CTR was achieved earlier in the PAT-treated group compared with the radiation alone group. Conclusions An iron oxide nanoparticle enhanced therapeutic effect with relatively low tissue concentration of iron and 10 Gy of monochromatic X-rays. Since 7.1 keV X-rays is attenuated very sharply in the tissue, FeO NP-PAT may have promise as a potent treatment option for superficial malignancies in the skin, like chest wall recurrence of breast cancer. PMID:23111059
Chest radiographic characteristics of community-acquired Legionella pneumonia in the elderly.
Zhang, Zhigang; Liu, Xinmin; Chen, Luzeng; Qiu, Jianxing
2014-01-01
Legionella is an important community-acquired pneumonia pathogen. Although the elderly are especially susceptible to Legionella, few studies have looked at comparative radiographic features of Legionella pneumonia in this population. The aim of this study was to explore the chest radiographic characteristics of community-acquired Legionella pneumonia in the elderly. Serial chest radiographs obtained in 34 patients hospitalized with serologically proven Legionella pneumonia were retrospectively reviewed. Chest X-ray features of an aged group of ≥ 65 years were assessed and compared with a non-aged group of <65 years old with regard to initial patterns and distributions of pulmonary abnormalities, accompanying signs, and progression. The most common initial presentation was a patchy alveolar infiltrate involving a single lobe, most often the lower lobe. There was no middle or lingular lobe involvement in the aged group patients, but bilateral pleural effusion was significantly more common in this group. In the aged group patients, radiographic progression following adequate therapy, despite a clinical response, was more often noted and the radiographs were less likely to have returned to the premorbid state at discharge, but the differences were not significant between the two groups. The discrepancy between imaging findings and clinical symptoms seems more prominent in community-acquired Legionella pneumonia in the elderly.
Darwish, Bassam; Mahfouz, Mohammad Z; Izzat, Mohammad Bashar
2018-05-02
This review was conducted to compare the contributions of chest X-ray (CXR) and computed tomography (CT) towards detecting intrathoracic damage in patients with penetrating war injuries to the chest and to determine whether identification of additional injuries by chest CT will have an impact on the choice of therapeutic interventions and clinical outcomes. We reviewed records of 449 patients (374 men, mean age 29.3 ± 14.8 years) who were admitted to our hospital with penetrating war injuries to the chest over a 7-year period. Collected data included mechanisms of injury, associated injuries, results of CXRs and chest CTs, methods of management, in-hospital stays, complications and mortalities. Immediate screening CXRs were obtained in all patients not requiring emergent thoracotomies, of which 91.4% showed positive signs of injury. Chest CTs were performed at the discretion of the physicians in 49.4% of patients, and CXR-positive findings were confirmed in all cases, while revealing additional injuries in 11% of patients. Chest CT findings led to additional closed chest drainage in 5.6% of patients but had no impact on treatment strategy in 94.4% of scanned patients. Follow-up CXRs showed new positive findings in 22 patients, leading to additional closed chest drainage in 3 patients and delayed open thoracotomies in 7 other patients. CXRs continue as the primary diagnostic modality in the assessment of patients with penetrating war injuries to the chest. Chest CTs can be omitted in most patients, thus reducing CT imaging case-load substantially, while most clinically significant chest injuries remain sufficiently recognized.
TOPICAL REVIEW: Digital x-ray tomosynthesis: current state of the art and clinical potential
NASA Astrophysics Data System (ADS)
Dobbins, James T., III; Godfrey, Devon J.
2003-10-01
Digital x-ray tomosynthesis is a technique for producing slice images using conventional x-ray systems. It is a refinement of conventional geometric tomography, which has been known since the 1930s. In conventional geometric tomography, the x-ray tube and image receptor move in synchrony on opposite sides of the patient to produce a plane of structures in sharp focus at the plane containing the fulcrum of the motion; all other structures above and below the fulcrum plane are blurred and thus less visible in the resulting image. Tomosynthesis improves upon conventional geometric tomography in that it allows an arbitrary number of in-focus planes to be generated retrospectively from a sequence of projection radiographs that are acquired during a single motion of the x-ray tube. By shifting and adding these projection radiographs, specific planes may be reconstructed. This topical review describes the various reconstruction algorithms used to produce tomosynthesis images, as well as approaches used to minimize the residual blur from out-of-plane structures. Historical background and mathematical details are given for the various approaches described. Approaches for optimizing the tomosynthesis image are given. Applications of tomosynthesis to various clinical tasks, including angiography, chest imaging, mammography, dental imaging and orthopaedic imaging, are also described.
Schaap, A.; Muyoyeta, M.; Mulenga, D.; Brown, J.; Ayles, H.
2012-01-01
Setting: In August 2009, a digital chest X-ray (CXR) machine was installed at a busy urban health centre in Lusaka, Zambia. Objective: To describe the changes in tuberculosis (TB) notifications and treatment delay ≥7 days in Zambia after introducing a digital X-ray service. Design: Operational retrospective research of TB notification, laboratory and CXR data for Q4 2008 (prior to digital CXR) compared to Q4 2009. Results: Notifications for sputum smear-negative TB increased by 8.1%, from 370/527 (70.2%) in Q4 2008 to 425/544 (78.1%) in Q4 2009, despite a 6.7% decrease in sputum smear positivity in Q4 2009. TB treatment delay decreased from 75/412 (18.2%) in Q4 2008 to 52/394 (13.2%) in Q4 2009 (P = 0.05). Conclusion: In Q4 2009, sputum smear-negative TB notifications increased and treatment delay decreased. However, accurate diagnosis of TB is challenging in this setting, and misdiagnosis and overtreatment may occur. Moreover, other factors in addition to the introduction of the digital X-ray service could have contributed to these findings. Nonetheless, we found that the digital X-ray service had many advantages and that it may aid in more efficient TB diagnosis. PMID:26392952
Treatment of Adult Severe Traumatic Brain Injury Using Autologous Bone Marrow Mononuclear Cells
2013-06-01
P:F value was aberrant based on wean protocol/vent settings. The chest X-ray for this day and the next did show pathology specifically pleural ... effusion and atelectasis, but no diffuse opacities consistent with ARDS/ALI. 3 Subject 10, Day 3 – On this day the subject was started on Dobhoff tube
20 CFR 410.418 - Irrebuttable presumption of total disability due to pneumoconiosis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... FEDERAL COAL MINE HEALTH AND SAFETY ACT OF 1969, TITLE IV-BLACK LUNG BENEFITS (1969- ) Total Disability or... suffered from a chronic dust disease of the lung which: (a) When diagnosed by chest roentgenogram (X-ray... of the Union Internationale Contra Cancer/Cincinnati (1968) (which may be referred to as the “UICC...
42 CFR 37.4 - Plans for chest roentgenographic examinations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... name and location of the approved X-ray facility or facilities, and the approximate date(s) and time(s... shall promptly display in a visible location on the bulletin board at the mine its proposed plan or... posted in a visible location on the bulletin board until ALOSH either grants or denies approval of it at...
42 CFR 37.4 - Plans for chest roentgenographic examinations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... name and location of the approved X-ray facility or facilities, and the approximate date(s) and time(s... shall promptly display in a visible location on the bulletin board at the mine its proposed plan or... posted in a visible location on the bulletin board until ALOSH either grants or denies approval of it at...
42 CFR 37.4 - Plans for chest roentgenographic examinations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... name and location of the approved X-ray facility or facilities, and the approximate date(s) and time(s... shall promptly display in a visible location on the bulletin board at the mine its proposed plan or... posted in a visible location on the bulletin board until ALOSH either grants or denies approval of it at...
Abnormal location of umbilical venous catheter due to Scimitar syndrome
Mart, Christopher R; Van Dorn, Charlotte S
2014-01-01
Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705
The x-ray light valve: a low-cost, digital radiographic imaging system-spatial resolution
NASA Astrophysics Data System (ADS)
MacDougall, Robert D.; Koprinarov, Ivaylo; Webster, Christie A.; Rowlands, J. A.
2007-03-01
In recent years, new x-ray radiographic systems based on large area flat panel technology have revolutionized our capability to produce digital x-ray radiographic images. However, these active matrix flat panel imagers (AMFPIs) are extraordinarily expensive compared to the systems they are replacing. Thus there is a need for a low cost digital imaging system for general applications in radiology. Different approaches have been considered to make lower cost, integrated x-ray imaging devices for digital radiography, including: scanned projection x-ray, an integrated approach based on computed radiography technology and optically demagnified x-ray screen/CCD systems. These approaches suffer from either high cost or high mechanical complexity and do not have the image quality of AMFPIs. We have identified a new approach - the X-ray Light Valve (XLV). The XLV has the potential to achieve the immediate readout in an integrated system with image quality comparable to AMFPIs. The XLV concept combines three well-established and hence lowcost technologies: an amorphous selenium (a-Se) layer to convert x-rays to image charge, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. Here we investigate the spatial resolution possible with XLV systems. Both a-Se and LC cells have both been shown separately to have inherently very high spatial resolution. Due to the close electrostatic coupling in the XLV, it can be expected that the spatial resolution of this system will also be very high. A prototype XLV was made and a typical office scanner was used for image digitization. The Modulation Transfer Function was measured and the limiting factor was seen to be the optical scanner. However, even with this limitation the XLV system is able to meet or exceed the resolution requirements for chest radiography.
[Detection of lung nodules. New opportunities in chest radiography].
Pötter-Lang, S; Schalekamp, S; Schaefer-Prokop, C; Uffmann, M
2014-05-01
Chest radiography still represents the most commonly performed X-ray examination because it is readily available, requires low radiation doses and is relatively inexpensive. However, as previously published, many initially undetected lung nodules are retrospectively visible in chest radiographs. The great improvements in detector technology with the increasing dose efficiency and improved contrast resolution provide a better image quality and reduced dose needs. The dual energy acquisition technique and advanced image processing methods (e.g. digital bone subtraction and temporal subtraction) reduce the anatomical background noise by reduction of overlapping structures in chest radiography. Computer-aided detection (CAD) schemes increase the awareness of radiologists for suspicious areas. The advanced image processing methods show clear improvements for the detection of pulmonary lung nodules in chest radiography and strengthen the role of this method in comparison to 3D acquisition techniques, such as computed tomography (CT). Many of these methods will probably be integrated into standard clinical treatment in the near future. Digital software solutions offer advantages as they can be easily incorporated into radiology departments and are often more affordable as compared to hardware solutions.
An ingested foreign body: two sides of the same coin?
Varadharajan, Kiran; Magill, Jennifer; Patel, Kalpesh
2014-04-09
A 2-year-old child presented to the emergency department with an acute onset of dysphagia and stertor. A plain anteroposterior chest X-ray revealed a single circular opacity in the middle third of the oesophagus consistent with an ingested coin. The child was taken to the theatre for rigid pharyngo-oesophagoscopy and removal of the coin. After the first coin was removed subsequent endoscopic examination revealed a second coin at the same location. This extremely rare case of two ingested coins becoming impacted with perfect radiological alignment emphasises the importance of thorough examination on endoscopy and the potential limitations of an X-ray in initial assessment of an ingested foreign body.
An ingested foreign body: two sides of the same coin?
Varadharajan, Kiran; Magill, Jennifer; Patel, Kalpesh
2014-01-01
A 2-year-old child presented to the emergency department with an acute onset of dysphagia and stertor. A plain anteroposterior chest X-ray revealed a single circular opacity in the middle third of the oesophagus consistent with an ingested coin. The child was taken to the theatre for rigid pharyngo-oesophagoscopy and removal of the coin. After the first coin was removed subsequent endoscopic examination revealed a second coin at the same location. This extremely rare case of two ingested coins becoming impacted with perfect radiological alignment emphasises the importance of thorough examination on endoscopy and the potential limitations of an X-ray in initial assessment of an ingested foreign body. PMID:24717590
Incidence and sites of distant metastases from head and neck cancer.
Ferlito, A; Shaha, A R; Silver, C E; Rinaldo, A; Mondin, V
2001-01-01
The incidence of distant metastases in head and neck squamous cell carcinoma (SCC) is relatively small in comparison to other malignancies. Distant metastases adversely impact survival and may significantly affect treatment planning. The incidence of distant metastases is influenced by location of the primary tumor, initial T and N stage of the neoplasm, and the presence or absence of regional control above the clavicle. Patients with advanced nodal disease have a high incidence of distant metastases, particularly in the presence of jugular vein invasion or extensive soft tissue disease in the neck. Primary tumors of advanced T stages in the hypopharynx, oropharynx and oral cavity are associated with the highest incidence of distant metastases. Pulmonary metastases are the most frequent in SCC, accounting for 66% of distant metastases. It may be difficult to distinguish pulmonary metastasis from a new primary tumor, particularly if solitary. Other metastatic sites include bone (22%), liver (10%), skin, mediastinum and bone marrow. An important question remains as to how intensely pre- and postoperative screening for distant metastases should be performed. Preoperative chest X-ray is warranted in all cases. If the primary tumor and nodal status place the patient at high risk for pulmonary metastasis, then preoperative computed tomography scan of the chest should be done. Screening for distant metastases at other sites is usually not indicated in SCC of the upper aerodigestive tract. Postoperatively, annual X-rays of the chest are usually sufficient, but in high-risk situations a chest X-ray performed every 3-6 months may be beneficial. Certain histologic types of primary tumor have greater or lesser propensity to metastasize distantly, and have a different natural history. Adenoid cystic carcinoma metastasizes frequently, even in the absence of extensive local or regional disease. Basaloid squamous cell carcinoma and neuroendocrine carcinomas also metastasize widely. Extensive evaluation for distant metastases is justified for these tumors. Knowledge of the natural history of various neoplasms and the factors that contribute to distant metastases as well as good judgement are essential for cost-effective treatment planning and decision-making with regard to pre- and postoperative evaluation for distant metastases in cancer of the head and neck. Copyright 2001 S. Karger AG, Basel
Lung boundary detection in pediatric chest x-rays
NASA Astrophysics Data System (ADS)
Candemir, Sema; Antani, Sameer; Jaeger, Stefan; Browning, Renee; Thoma, George R.
2015-03-01
Tuberculosis (TB) is a major public health problem worldwide, and highly prevalent in developing countries. According to the World Health Organization (WHO), over 95% of TB deaths occur in low- and middle- income countries that often have under-resourced health care systems. In an effort to aid population screening in such resource challenged settings, the U.S. National Library of Medicine has developed a chest X-ray (CXR) screening system that provides a pre-decision on pulmonary abnormalities. When the system is presented with a digital CXR image from the Picture Archive and Communication Systems (PACS) or an imaging source, it automatically identifies the lung regions in the image, extracts image features, and classifies the image as normal or abnormal using trained machine-learning algorithms. The system has been trained on adult CXR images, and this article presents enhancements toward including pediatric CXR images. Our adult lung boundary detection algorithm is model-based. We note the lung shape differences during pediatric developmental stages, and adulthood, and propose building new lung models suitable for pediatric developmental stages. In this study, we quantify changes in lung shape from infancy to adulthood toward enhancing our lung segmentation algorithm. Our initial findings suggest pediatric age groupings of 0 - 23 months, 2 - 10 years, and 11 - 18 years. We present justification for our groupings. We report on the quality of boundary detection algorithm with the pediatric lung models.
Radiology residents' skill level in chest x-ray reading.
Fabre, C; Proisy, M; Chapuis, C; Jouneau, S; Lentz, P-A; Meunier, C; Mahé, G; Lederlin, M
2018-05-04
To evaluate the mean skill level of radiology residents in chest X-ray (CXR) reading, with regard to cognitive mechanisms involved in this task and to investigate for potential factors influencing residents' skill. Eighty-one residents were evaluated through a test set including CXR expected to mobilize detection skills (n=10), CXR expected to mobilize interpretation skills (n=10) and normal CXR (n=4). For each radiograph, residents were asked to answer three questions: Does this radiograph show normal or abnormal findings? Does it require complementary computed tomography study? What is your diagnosis? Residents' answers were evaluated against an experts' consensus and analyzed according to year of residency, attendance at CXR training course during residency and the average number of CXR read per week. Residents' mean success rate was 90.4%, 76.6% and 52.7% for the three questions, respectively. Year of residency was associated with better diagnostic performances in the detection CXR category (P=0.025), while attendance at CXR training course was associated with better performances in the interpretation CXR category (P=0.031). There was no influence of the number of CXR read per week. These results may suggest promoting systematic CXR theoretical training course in the curriculum of radiology residents. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Caggiano, Serena; Ullmann, Nicola; De Vitis, Elisa; Trivelli, Marzia; Mariani, Chiara; Podagrosi, Maria; Ursitti, Fabiana; Bertolaso, Chiara; Putotto, Carolina; Unolt, Marta; Pietravalle, Andrea; Pansa, Paola; Mphayokulela, Kajoro; Lemmo, Maria Incoronata; Mkwambe, Michael; Kazaura, Joseph; Duse, Marzia; Nieddu, Francesco; Azzari, Chiara; Cutrera, Renato
2017-01-01
Community-acquired pneumonia (CAP) is still the most important cause of death in countries with scarce resources. All children (33 months ± 35 DS) discharged from the Pediatric Unit of Itigi Hospital, Tanzania, with a diagnosis of CAP from August 2014 to April 2015 were enrolled. Clinical data were gathered. Dried blood spot (DBS) samples for quantitative real-time polymerase chain reaction (PCR) for bacterial detection were collected in all 100 children included. Twenty-four percent of patients were identified with severe CAP and 11% died. Surprisingly, 54% of patients were admitted with a wrong diagnosis, which increased complications, the need for antibiotics and chest X-rays, and the length of hospitalization. Comorbidity, found in 32% of children, significantly increased severity, complications, deaths, need for chest X-rays, and oxygen therapy. Malnourished children (29%) required more antibiotics. Microbiologically, Streptococcus pneumonia (S. p.), Haemophilus influenza type b (Hib) and Staphylococcus aureus (S. a.) were the bacteria more frequently isolated. Seventy-five percent of patients had mono-infection. Etiology was not correlated with severity, complications, deaths, oxygen demand, or duration of hospitalization. Our study highlights that difficult diagnoses and comorbidities negatively affect clinical evolution. S. p. and Hib still play a large role; thus, implementation of current vaccine strategies is needed. DBS is a simple and efficient diagnostic method for bacterial identification in countries with scarce resources. PMID:28335406
Nicogossian, A; Hoffler, G W; Johnson, R L; Gowen, R J
1976-04-01
A simple method to estimate cardiac size from single frontal plane chest roentgenograms has been described. Pre- and postflight chest X-rays from Apollo 17, and Skylab 2 and 3 have been analyzed for changes in the cardiac silhouette size. The data obtained from the computed cardiothoracic areal ratios compared well with the clinical cardiothoracic diametral ratios (r = .86). Though an overall postflight decrease in cardiac size is evident, the mean difference was not statistically significant (n = 8). The individual decreases in the cardiac silhouette size postflight are thought to be due to decrements in intracardiac chamber volumes rather than in myocardial muscle mass.
Delayed lead perforation: a disturbing trend.
Khan, Mohammed N; Joseph, George; Khaykin, Yaariv; Ziada, Khaled M; Wilkoff, Bruce L
2005-03-01
Delayed lead perforation (occurring more than 1 month after implantation) is a rare complication. Its pathophysiology and optimal management are currently unclear. Three cases of delayed lead perforation (6-10 month) were identified in patients with low-profile active fixation leads. All cases presented in a subacute fashion with pleuritic chest pain with confirmatory chest x-ray and device interrogation. Given the potential complications of a perforated lead, all cases had the lead extracted under TEE observation with cardiac surgery backup in the operating room. All patients tolerated extraction without complication. Based on these cases, we recommend a management scheme for patients who present with delayed lead perforation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moses, S.C.; Baker, S.R.; Seldin, M.F.
1983-12-01
A homosexual man with A.I.D.S. (acquired immunologic deficiency syndrome) and pneumocystis infestation was found to have diffuse Ga-67 uptake in the lungs with a coincident negative chest x-ray. While Ga-67 accumulates diffusely in the lungs in a variety of conditions, the present case is the first described in a patient with A.I.D.S. in which Ga-67 was positive before roentgenographic abnormalities were demonstrated. Thus, the use of Ga-67 scan, when A.I.D.S. is suspected, could help establish a diagnosis more promptly.
NASA Technical Reports Server (NTRS)
Nicogossian, A.; Hoffler, G. W.; Johnson, R. L.; Gowen, R. J.
1976-01-01
A simple method to estimate cardiac size from single frontal plane chest roentgenograms has been described. Pre- and postflight chest X-rays from Apollo 17, and Skylab 2 and 3 have been analyzed for changes in the cardiac silhouette size. The data obtained from the computed cardiothoracic areal ratios compared well with the clinical cardiothoracic diametral ratios (r = .86). Though an overall postflight decrease in cardiac size is evident, the mean difference was not statistically significant (n = 8). The individual decreases in the cardiac silhouette size postflight are thought to be due to decrements in intracardiac chamber volumes rather than in myocardial muscle mass.
Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S
2011-04-01
Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.
Respiratory damage in children exposed to urban pollution.
Calderón-Garcidueñas, Lilian; Mora-Tiscareño, Antonieta; Fordham, Lynn A; Valencia-Salazar, Gildardo; Chung, Charles J; Rodriguez-Alcaraz, Antonio; Paredes, Rogelio; Variakojis, Daina; Villarreal-Calderón, Anna; Flores-Camacho, Lourdes; Antunez-Solis, Angelina; Henríquez-Roldán, Carlos; Hazucha, Milan J
2003-08-01
Southwest Metropolitan Mexico City (SWMMC) children are chronically exposed to complex mixtures of air pollutants. In a cross-sectional arm of our study, we investigated the association between exposure to SWMMC atmosphere and nasal abnormalities, hyperinflation, and interstitial markings assessed by chest X-rays, lung function changes, several serum cytokines, and endothelin-1 in 174 children aged 5-17 years vs. 27 control children residents in low-polluted areas. Control children had no nasal lesions, and only one child showed an abnormal chest X-ray. SWMMC children exhibited nasal abnormalities (22%), hyperinflation (67%), interstitial markings (49%), and a mild restrictive pattern by spirometry (10%). Interstitial markings were associated with a decrease in predicted values of FEF(25-75), FEF(75), and the FEV(1)/FVC ratio. Boys had a higher probability of developing interstitial markings with age (P = 0.004). Blood smear findings included toxic granulations in neutrophils and schistocytes. SWMMC children had more serum IL10 and IL6 and less IL8 than controls. In a longitudinal arm of our study, we found a significant seasonal drop in FVC and FEV(1) associated with a 6-month period of high ozone and PM(10) levels. Our data strongly suggest that a lifelong exposure to urban air pollution causes respiratory damage in children. Moreover, a cytokine network becomes imbalanced, with a shift towards upregulation of anti-inflammatory cytokines. Consequently, these children are potentially at risk for developing chronic lung disease and other systemic effects later in life. Copyright 2003 Wiley-Liss, Inc.
Bilateral Pneumothoraces in a Trauma Patient After Dobhoff Tube Insertion.
Abidali, Ali; Mangram, Alicia; Shirah, Gina R; Wilson, Whitney; Abidali, Ahmed; Moeser, Phillip; Dzandu, James K
2018-03-05
BACKGROUND Dobhoff tube insertion is a common procedure used in the clinical setting to deliver enteral nutrition. Although it is often viewed as an innocuous bedside procedure, there are risks for numerous complications such as tracheobronchial insertion, which could lead to deleterious consequences. We present to our knowledge the first reported case of bilateral pneumothoraces caused by the insertion of a Dobhoff tube. In addition, we also discuss common pitfalls for confirming the positioning of Dobhoff tubes, as well as risk factors that can predispose a patient to improper tube placement. CASE REPORT We present the case of a 74-year-old male patient with multiple orthopedic injuries following an auto-pedestrian collision. Five attempts were made to place a Dobhoff tube to maintain enteral nutrition. Follow-up abdominal x-ray revealed displacement of the Dobhoff tube in the left pleural space. After removal of the tube, a follow-up chest x-ray revealed iatrogenic bilateral pneumothoraces. Acute hypoxemic respiratory failure ensued; therefore, bilateral chest tubes were placed. Over the next three weeks, the patient's respiratory status improved and both chest tubes were removed. The patient was eventually discharged to a skilled nursing facility. CONCLUSIONS Improper placement of Dobhoff tubes can lead to rare complications such as bilateral pneumothoraces. This unique case report of bilateral pneumothoraces after Dobhoff tube placement emphasizes the necessity of using proper diagnostic techniques for verifying proper tube placement, as well as understanding the risk factors that predispose a patient to a malpositioned tube.
A fatal nail gun injury--an unusual ricochet?
Nadesan, K
2000-01-01
An 18-year-old construction worker suddenly collapsed while handling a power-actuated nail gun and died shortly after. A neat, almost circular puncture wound was found on the front of his left chest. No fire-arm residues were detected on the surrounding skin. The police stated that it was an accidental injury, at a construction site, where a nail fired from a nail gun by the deceased had deflected off the wall and struck him on the front of the chest. Since the entry wound appeared to be a neat hole, and that too on the front of the left chest overlying the heart area, there was reluctance on the part of the pathologist to accept it as an accidental injury due to a ricochet. A visit to the scene, interrogation of witnesses, examination of the alleged tool and post-mortem X-ray of the deceased were undertaken prior to autopsy. A bent nail was found in the heart. The scene visit and the subsequent autopsy revealed that the nail took a roughly circular flightpath after it had struck the wall, all the while travelling with its pointed end directed forward. Within the body too, the nail maintained the same path. Various medicolegal issues are discussed pertaining to nail-gun injuries. The importance of a visit to the scene, examination of the alleged tool, interrogation of witnesses and the X-ray of the body, all prior to autopsy, are emphasized. The conclusion was: accidental death due to the unusual ricochet of a nail.
Utility of extended FAST in blunt chest trauma: is it the time to be used in the ATLS algorithm?
Abdulrahman, Yassir; Musthafa, Shameel; Hakim, Suhail Y; Nabir, Syed; Qanbar, Ahad; Mahmood, Ismail; Siddiqui, Tariq; Hussein, Wafaa A; Ali, Hazim H; Afifi, Ibrahim; El-Menyar, Ayman; Al-Thani, Hassan
2015-01-01
The clinical significance of extended Focused Assessment with Sonography for Trauma (EFAST) for diagnosis of pneumothorax is not well defined. To investigate the utility of EFAST in blunt chest trauma (BCT) patients. A single blinded, prospective study. All patients admitted with BCT (2011-2013). Level 1 trauma center in Qatar. Patients were screened by EFAST and results were compared to the clinical examination (CE) and chest X-ray (CXR). Chest-computed tomography (CT) scoring system was used to confirm and measure the pneumothorax. Diagnostic accuracy of diagnostic modalities of pneumothorax was measured using sensitivity, specificity, predictive values (PVs), and likelihood ratio. A total of 305 BCT patients were included with median age of 34 (18-75). Chest CT was positive for pneumothorax in 75 (24.6 %) cases; of which 11 % had bilateral pneumothorax. Chest CT confirmed the diagnosis of pneumothorax in 43, 41, and 11 % of those who were initially diagnosed by EFAST, CE, and CXR, respectively. EFAST was positive in 42 hemithoraces and its sensitivity (43 %) was higher in comparison to CXR (11 %). Positive and negative PVs of EFAST were 76 and 92 %, respectively. The frequency of missed cases by CXR was higher in comparison to EFAST and CE. The lowest median score of missed pneumothorax was observed by EFAST. EFAST can be used as an efficient triaging tool in BCT patients to rule out pneumothorax. Based on our analysis, we would recommend EFAST as an adjunct in ATLS algorithm.
2012-01-01
Background Inter-rater agreement in the interpretation of chest X-ray (CXR) films is crucial for clinical and epidemiological studies of tuberculosis. We compared the readings of CXR films used for a survey of tuberculosis between raters from two Asian countries. Methods Of the 11,624 people enrolled in a prevalence survey in Hanoi, Viet Nam, in 2003, we studied 258 individuals whose CXR films did not exclude the possibility of active tuberculosis. Follow-up films obtained from accessible individuals in 2006 were also analyzed. Two Japanese and two Vietnamese raters read the CXR films based on a coding system proposed by Den Boon et al. and another system newly developed in this study. Inter-rater agreement was evaluated by kappa statistics. Marginal homogeneity was evaluated by the generalized estimating equation (GEE). Results CXR findings suspected of tuberculosis differed between the four raters. The frequencies of infiltrates and fibrosis/scarring detected on the films significantly differed between the raters from the two countries (P < 0.0001 and P = 0.0082, respectively, by GEE). The definition of findings such as primary cavity, used in the coding systems also affected the degree of agreement. Conclusions CXR findings were inconsistent between the raters with different backgrounds. High inter-rater agreement is a component necessary for an optimal CXR coding system, particularly in international studies. An analysis of reading results and a thorough discussion to achieve a consensus would be necessary to achieve further consistency and high quality of reading. PMID:22296612
A radiographic method to estimate lung volume and its use in small mammals.
Canals, Mauricio; Olivares, Ricardo; Rosenmann, Mario
2005-01-01
In this paper we develop a method to estimate lung volume using chest x-rays of small mammals. We applied this method to assess the lung volume of several rodents. We showed that a good estimator of the lung volume is: V*L = 0.496 x VRX approximately equal to 1/2 x VRX, where VRX is a measurement obtained from the x-ray that represents the volume of a rectangular box containing the lungs and mediastinum organs. The proposed formula may be interpreted as the volume of an ellipsoid formed by both lungs joined at their bases. When that relationship was used to estimate lung volume, values similar to those expected from allometric relationship were found in four rodents. In two others, M. musculus and R. norvegicus, lung volume was similar to reported data, although values were lower than expected.
NASA Astrophysics Data System (ADS)
Moore, Craig S.; Wood, Tim J.; Saunderson, John R.; Beavis, Andrew W.
2017-09-01
The use of computer simulated digital x-radiographs for optimisation purposes has become widespread in recent years. To make these optimisation investigations effective, it is vital simulated radiographs contain accurate anatomical and system noise. Computer algorithms that simulate radiographs based solely on the incident detector x-ray intensity (‘dose’) have been reported extensively in the literature. However, while it has been established for digital mammography that x-ray beam quality is an important factor when modelling noise in simulated images there are no such studies for diagnostic imaging of the chest, abdomen and pelvis. This study investigates the influence of beam quality on image noise in a digital radiography (DR) imaging system, and incorporates these effects into a digitally reconstructed radiograph (DRR) computer simulator. Image noise was measured on a real DR imaging system as a function of dose (absorbed energy) over a range of clinically relevant beam qualities. Simulated ‘absorbed energy’ and ‘beam quality’ DRRs were then created for each patient and tube voltage under investigation. Simulated noise images, corrected for dose and beam quality, were subsequently produced from the absorbed energy and beam quality DRRs, using the measured noise, absorbed energy and beam quality relationships. The noise images were superimposed onto the noiseless absorbed energy DRRs to create the final images. Signal-to-noise measurements in simulated chest, abdomen and spine images were within 10% of the corresponding measurements in real images. This compares favourably to our previous algorithm where images corrected for dose only were all within 20%.
Thymolipoma combined with hyperthyroidism discovered by neurological symptoms.
Takahashi, Hidenobu; Harada, Masahiko; Kimura, Masakazu; Kato, Harubumi
2007-04-01
Thymolipomas are rare slow-growing mediastinal thymic neoplasms. Most cases are asymptomatic and are sometimes discovered as a huge mass on chest x-ray films. A few cases have been discovered during examinations for other diseases. We report the second case of thymolipoma combined with hyperthyroidism in the English language literature. Neurological symptoms suddenly appeared in a 45-year-old woman. Central nervous system disorder was suggested but no significant abnormalities were found on brain MR nor were there any neurological signs. Several months later, neurological and systemic examinations on admission revealed hyperthyroidism and an anterior mediastinal tumor, 9.0x5.0x3.0 cm in size on chest CT films. Despite treatment of hyperthyroidism by medication, her neurological symptoms remained. Neurologists recommended resection of the mediastinal tumor. Malignancy could not be ruled out because of the irregularity of the tumor appearance on contrast-enhanced chest CT. Furthermore, the tumor appeared to be attached to the ascending aorta, so cytological and/or pathological diagnosis by CT-guided needle biopsy before operation were contraindicated. Extended thymectomy was performed in May 2005. The pathological diagnosis was benign thymolipoma consisting of mature fatty tissue and thymic tissue structures with Hassall's corpuscles. Her neurological symptoms seemed slightly but not markedly improved. The relationship between thymolipoma and hyperthyroidism is still unknown.
Semi-Automatic Terminology Generation for Information Extraction from German Chest X-Ray Reports.
Krebs, Jonathan; Corovic, Hamo; Dietrich, Georg; Ertl, Max; Fette, Georg; Kaspar, Mathias; Krug, Markus; Stoerk, Stefan; Puppe, Frank
2017-01-01
Extraction of structured data from textual reports is an important subtask for building medical data warehouses for research and care. Many medical and most radiology reports are written in a telegraphic style with a concatenation of noun phrases describing the presence or absence of findings. Therefore a lexico-syntactical approach is promising, where key terms and their relations are recognized and mapped on a predefined standard terminology (ontology). We propose a two-phase algorithm for terminology matching: In the first pass, a local terminology for recognition is derived as close as possible to the terms used in the radiology reports. In the second pass, the local terminology is mapped to a standard terminology. In this paper, we report on an algorithm for the first step of semi-automatic generation of the local terminology and evaluate the algorithm with radiology reports of chest X-ray examinations from Würzburg university hospital. With an effort of about 20 hours work of a radiologist as domain expert and 10 hours for meetings, a local terminology with about 250 attributes and various value patterns was built. In an evaluation with 100 randomly chosen reports it achieved an F1-Score of about 95% for information extraction.
Jung, Jae-Woo; Choi, Jae-Chol; Shin, Jong-Wook; Kim, Jae-Yeol; Choi, Byoung-Whui; Park, In-Won
2015-01-01
Pulmonary tuberculosis (TB) can affect lung function, but studies regarding long-term follow-up in patients with no sequelae on chest X-ray (CXR) have not been performed. We evaluated lung functional impairment and persistent respiratory symptoms in those with prior pulmonary TB and those with prior pulmonary TB with no residual sequelae on CXR, and determined risk factors for airflow obstruction. We used data from adults aged ≥ 40 years from the annual Korean National Health and Nutrition Examination Surveys conducted between 2008 and 2012. P values for comparisons were adjusted for age, sex, and smoking status. In total of 14,967 adults, 822 subjects (5.5%) had diagnosed and treated pulmonary TB (mean 29.0 years ago). The FVC% (84.9 vs. 92.6), FEV1% (83.4 vs. 92.4), and FEV1/FVC% (73.4 vs. 77.9) were significantly decreased in subjects with prior pulmonary TB compared to those without (p < 0.001, each). In 12,885 subjects with no sequalae on CXR, those with prior pulmonary TB (296, 2.3%) had significantly lower FEV1% (90.9 vs. 93.4, p = 0.001) and FEV1/FVC% (76.6 vs. 78.4, p < 0.001) than those without. Subjects with prior pulmonary TB as well as subjects with no sequalae on CXR were more likely to experience cough and physical activity limitations due to pulmonary symptoms than those without prior pulmonary TB (p < 0.001, each). In total subjects, prior pulmonary TB (OR, 2.314; 95% CI, 1.922-2.785), along with age, male, asthma, and smoking mount was risk factor for airflow obstruction. In subjects with prior pulmonary tuberculosis, inactive TB lesion on chest x-ray (OR, 2.300; 95% CI, 1.606-3.294) were risk factors of airflow obstruction. In addition to subjects with inactive TB lesion on CXR, subjects with no sequelae on CXR can show impaired pulmonary function and respiratory symptoms. Prior TB is a risk factor for airflow obstruction and that the risk is more important when they have inactive lesions on chest X-ray. Hence, the patients with treated TB should need to have regular follow-up of lung function and stop smoking for early detection and prevention of the chronic airway disease.
Facenda, Catherine; Vaz, Nuno; Castañeda, Edgar Augusto; del Amo, Montserrat; Garcia-Diez, Ana Isabel; Pomes, Jaime
2017-01-01
Blunt injuries to the chest wall are an important chapter on emergency room (ER) departments, being the third most common injuries in trauma patients which ominous complications could appear. This article describes different types of traumatic events affecting the chest wall, which maybe misdiagnosed with conventional X-ray. Special emphasis has been done in computed tomography (CT) and multidetector CT (MDCT) imaging. This technique is considered the “gold-standard” for those traumatic patients, due to its fast acquisition covering the whole area of interest in axial plane, reconstructing multiplanar (2D, 3D) volume-rendered images with a superb quality and angiographic CT capabilities for evaluating vascular damage. Complementary techniques such as ultrasonography (US) and magnetic resonance imaging (MRI) may improve the diagnostic accuracy due to its great capacity in visualising soft-tissue trauma (muscle-tendinous tears) and subtle fractures. All these imaging methods have an important role in quantifying the severity of chest wall trauma. The findings of this study have been exposed with cases of our archives in a didactic way. PMID:28932697
[Internal fixation treatment of multiple rib fractures with absorbable rib-connecting-pins].
Liu, Jinliang; Li, Keyao; He, Jianning
2011-01-01
To study the indications, methods, and therapeutic effect of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. Between March 2007 and September 2009, 40 patients with multiple rib fractures received internal fixation with absorbable rib-connecting-pins, including 8 one-side flail chest and 1 two-side flail chest. There were 32 males and 8 females with an average age of 39.8 years (range, 25-72 years). The injury was caused by traffic accident in 32 cases, falling from height in 6 cases, and blunt hitting in 2 cases. Preoperatively, imaging data of the chest X-ray or spiral CT three-dimensional (3D) examination showed that all patients had multiple ribs fractures and displacement. The number of fractured ribs was 4-10 (median, 6), and the fracture location ranged from the 2nd to the 10th ribs. Of them, 28 cases were accompanied by hemathorax, pneumothorax or hemopneumothorax; 5 cases by thoracic organ injury; and 10 cases by other part trauma. The time from injury to hospitalization was less than 1 day in 26 cases, 1-3 days in 12 cases, and 3-6 days in 2 cases, and the time from hospitalization to operation was 3 hours to 3 days (mean, 1.2 days). The median fixation rib number was 5 (range, 3-8). The mean operative time, the time in bed, and hospitalization days were 32 minutes (range, 15-50 minutes), 4.5 days (range, 2-7 days), and 11.2 days (range, 5-18 days), respectively. All incisions healed by first intention. No pulmonary infection, pulmonary atelectasis, intrathoracic infection or other complications occurred. All cases were followed up 6-12 months (mean, 8 months). PaO2 [(86.6 +/- 2.2) mmHg (1 mm Hg = 0.133 kPa)] and SpO2 (97.2% +/- 0.6%) at 2 hours after operation were obviously improved when compared with preoperative ones (PaO2 (53.6 + 4.7) mm Hg and SpO2 (86.2% + 1.8%)], showing significant differences (t = 2.971, P = 0.005; t = 2.426, P = 0.020). The chest X-ray films or spiral CT 3D indicated that fracture of rib healed within 3-6 months (mean, 4.5 months) after operation. Severe collapsed chest wall or flail chest caused by fracture of multiple ribs should be treated by absorbable rib-connecting-pins, which is a simple, firm, and effective method.
Loomba, Rohit S; Shah, Parinda H; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit
2015-03-01
Increased cardiothoracic ratio noted on chest radiographs often prompts concern and further evaluation with additional imaging. This study pools available data assessing the utility of cardiothoracic ratio in predicting left ventricular dilation. A systematic review of the literature was conducted to identify studies comparing cardiothoracic ratio by chest x-ray to left ventricular dilation by echocardiography. Electronic databases were used to identify studies which were then assessed for quality and bias, with those with adequate quality and minimal bias ultimately being included in the pooled analysis. The pooled data were used to determine the sensitivity, specificity, positive predictive value and negative predictive value of cardiomegaly in predicting left ventricular dilation. A total of six studies consisting of 466 patients were included in this analysis. Cardiothoracic ratio had 83.3% sensitivity, 45.4% specificity, 43.5% positive predictive value and 82.7% negative predictive value. When a secondary analysis was conducted with a pediatric study excluded, a total of five studies consisting of 371 patients were included. Cardiothoracic ratio had 86.2% sensitivity, 25.2% specificity, 42.5% positive predictive value and 74.0% negative predictive value. Cardiothoracic ratio as determined by chest radiograph is sensitive but not specific for identifying left ventricular dilation. Cardiothoracic ratio also has a strong negative predictive value for identifying left ventricular dilation.
3D intrathoracic region definition and its application to PET-CT analysis
NASA Astrophysics Data System (ADS)
Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.
2014-03-01
Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.
Automatic estimation of heart boundaries and cardiothoracic ratio from chest x-ray images
NASA Astrophysics Data System (ADS)
Dallal, Ahmed H.; Agarwal, Chirag; Arbabshirani, Mohammad R.; Patel, Aalpen; Moore, Gregory
2017-03-01
Cardiothoracic ratio (CTR) is a widely used radiographic index to assess heart size on chest X-rays (CXRs). Recent studies have suggested that also two-dimensional CTR might contain clinical information about the heart function. However, manual measurement of such indices is both subjective and time consuming. This study proposes a fast algorithm to automatically estimate CTR indices based on CXRs. The algorithm has three main steps: 1) model based lung segmentation, 2) estimation of heart boundaries from lung contours, and 3) computation of cardiothoracic indices from the estimated boundaries. We extended a previously employed lung detection algorithm to automatically estimate heart boundaries without using ground truth heart markings. We used two datasets: a publicly available dataset with 247 images as well as clinical dataset with 167 studies from Geisinger Health System. The models of lung fields are learned from both datasets. The lung regions in a given test image are estimated by registering the learned models to patient CXRs. Then, heart region is estimated by applying Harris operator on segmented lung fields to detect the corner points corresponding to the heart boundaries. The algorithm calculates three indices, CTR1D, CTR2D, and cardiothoracic area ratio (CTAR). The method was tested on 103 clinical CXRs and average error rates of 7.9%, 25.5%, and 26.4% (for CTR1D, CTR2D, and CTAR respectively) were achieved. The proposed method outperforms previous CTR estimation methods without using any heart templates. This method can have important clinical implications as it can provide fast and accurate estimate of cardiothoracic indices.
Diagnostic value of radiological imaging pre- and post-drainage of pleural effusions.
Corcoran, John P; Acton, Louise; Ahmed, Asia; Hallifax, Robert J; Psallidas, Ioannis; Wrightson, John M; Rahman, Najib M; Gleeson, Fergus V
2016-02-01
Patients with an unexplained pleural effusion often require urgent investigation. Clinical practice varies due to uncertainty as to whether an effusion should be drained completely before diagnostic imaging. We performed a retrospective study of patients undergoing medical thoracoscopy for an unexplained effusion. In 110 patients with paired (pre- and post-drainage) chest X-rays and 32 patients with paired computed tomography scans, post-drainage imaging did not provide additional information that would have influenced the clinical decision-making process. © 2015 Asian Pacific Society of Respirology.
Ad Hoc Information Extraction for Clinical Data Warehouses.
Dietrich, Georg; Krebs, Jonathan; Fette, Georg; Ertl, Maximilian; Kaspar, Mathias; Störk, Stefan; Puppe, Frank
2018-05-01
Clinical Data Warehouses (CDW) reuse Electronic health records (EHR) to make their data retrievable for research purposes or patient recruitment for clinical trials. However, much information are hidden in unstructured data like discharge letters. They can be preprocessed and converted to structured data via information extraction (IE), which is unfortunately a laborious task and therefore usually not available for most of the text data in CDW. The goal of our work is to provide an ad hoc IE service that allows users to query text data ad hoc in a manner similar to querying structured data in a CDW. While search engines just return text snippets, our systems also returns frequencies (e.g. how many patients exist with "heart failure" including textual synonyms or how many patients have an LVEF < 45) based on the content of discharge letters or textual reports for special investigations like heart echo. Three subtasks are addressed: (1) To recognize and to exclude negations and their scopes, (2) to extract concepts, i.e. Boolean values and (3) to extract numerical values. We implemented an extended version of the NegEx-algorithm for German texts that detects negations and determines their scope. Furthermore, our document oriented CDW PaDaWaN was extended with query functions, e.g. context sensitive queries and regex queries, and an extraction mode for computing the frequencies for Boolean and numerical values. Evaluations in chest X-ray reports and in discharge letters showed high F1-scores for the three subtasks: Detection of negated concepts in chest X-ray reports with an F1-score of 0.99 and in discharge letters with 0.97; of Boolean values in chest X-ray reports about 0.99, and of numerical values in chest X-ray reports and discharge letters also around 0.99 with the exception of the concept age. The advantages of an ad hoc IE over a standard IE are the low development effort (just entering the concept with its variants), the promptness of the results and the adaptability by the user to his or her particular question. Disadvantage are usually lower accuracy and confidence.This ad hoc information extraction approach is novel and exceeds existing systems: Roogle [1] extracts predefined concepts from texts at preprocessing and makes them retrievable at runtime. Dr. Warehouse [2] applies negation detection and indexes the produced subtexts which include affirmed findings. Our approach combines negation detection and the extraction of concepts. But the extraction does not take place during preprocessing, but at runtime. That provides an ad hoc, dynamic, interactive and adjustable information extraction of random concepts and even their values on the fly at runtime. We developed an ad hoc information extraction query feature for Boolean and numerical values within a CDW with high recall and precision based on a pipeline that detects and removes negations and their scope in clinical texts. Schattauer GmbH.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frost, J.K.; Ball, W.C. Jr.; Levin, M.L.
Sputum cytopathologic monitoring detects squamous cell lung cancers at an extremely early stage (x-ray negative). It holds further potential for preventing disease by detecting epithelial alterations which reflect environmental hazards. The addition of sputum cytology screening to screening by chest x-ray film does not significantly reduce mortality from all types of lung cancer, but preliminary analysis of Johns Hopkins Lung Project data suggests that mortality from squamous cell carcinoma is reduced. Quantitative automated cytopathology systems and biochemical/immunological cell markers enhance understanding of these precursors and offer great promise for increasing capacity, accuracy, and usefulness in cytopathology screening of workers. Cytologicalmore » specimens collected over years of screening workers considered at risk may be important to eventually understanding development and prevention of major occupational diseases.« less
Steckel, R J; Batra, P; Johnson, S; Sayre, J; Brown, K; Haker, K; Young, D; Zucker, M
1995-04-01
This study was to determine whether different digital display formats for portable chest radiographs of coronary care unit patients would provide comparable information for clinical care. In particular, we tried to ascertain whether 1024 x 1024 pixel (1K) images on a picture archiving and communication system (PACS) workstation would be comparable to 1760 x 2140 pixel (2K) images on workstations or to digital films. If comparability could be proved, we hypothesized that 1K workstations could considerably lower equipment and film costs and facilitate image transmission from point to point. Four chest radiologists read a panel of chest studies assembled from 98 coronary care unit patients, comparing 1K and 2K soft-copy images with digital hard copies. For all three image types for the 98 patients, the readers evaluated nine image parameters that the cardiologists deemed essential for clinical decision making. Two other chest radiologists reviewed each patient's three image types, historical chest images, current and prior radiologic reports, and medical record to determine the consensus, or "truth findings." With one exception (small pleural effusions), the receiver operating characteristic analysis showed no significant differences in the clinical information derived from the three image types. For clinical management in a coronary care unit, comparable information can be obtained from digital radiologic chest studies using a 1K x 1K soft-copy format, a 2K x 2K soft-copy format, or a hard copy (film). Substantial savings in cost and time are therefore possible by using soft-copy images and lower resolution (1K x 1K) workstations and, when necessary, by transmitting images on regular telephone lines.
Bhatia, Risha; Schmölzer, Georg M; Davis, Peter G; Tingay, David G
2012-02-01
Diagnosis of pneumothorax relies on clinical suspicion and chest X-ray, and is often delayed. We aimed to determine whether electrical impedance tomography (EIT) can accurately identify the presence of surgically created pneumothoraces before significant changes in clinical parameters. Six anesthetized and muscle-relaxed piglets with surfactant-depleted lungs were studied. Following chest drain insertion into the right ventral chest, 10-20 ml aliquots of air were instilled into the pleural space to a maximum volume of 200 ml. The pneumothorax was drained by attaching a Heimlich valve to the chest drain. At each instillation and after draining the pneumothorax, global and regional end-expiratory intra-thoracic volumes (EEV) were measured using respiratory inductive plethysmography (RIP) and EIT concurrently with [Formula: see text], heart rate and blood pressure. A significantly greater change in both global EEV(RIP) and EEV within the right ventral quadrant was seen at all volume instillations, from as little as 10 ml, compared with all other quadrants. There was no difference in EEV within the left ventral and both dorsal quadrants. Sp(O)(2) fell below 90% at 100 ml instillation. Tachycardia occurred at 140 ml instillation. EIT identified a 60% resolution of pneumothoraces within 60 s of attachment of the Heimlich valve. EIT accurately detects very small pneumothoraces before physiological parameters change.
Trauma-induced "Macklin effect" with pneumothorax and large pneumomediastinum, disguised by allergy.
Di Saverio, Salomone; Kawamukai, Kenji; Biscardi, Andrea; Villani, Silvia; Zucchini, Luca; Tugnoli, Gregorio
2013-09-01
A 56-year-old man presented spontaneously to the Emergency Department complaining of facial and neck oedema after assumption of nonsteroidal anti-inflammatory drugs (NSAIDS). The triage nurse assigned the patient to Accident & Emergency (A&E) doctor as probable allergic reaction to NSAIDS. Chest X-ray (CXR), ordered after 24 hours, revealed a huge subcutaneous chest and neck emphysema without clearly visible pneumothorax. Subsequent chest CT scan showed a small left pneumothorax and a large amount of air in the mediastinum. The patient was conservatively treated since he was eupnoeic and hemodynamically stable. The pathophysiology of pneumomediastinum was first described by Macklin in 1939. The Macklin effect involves alveolar ruptures with air dissection along bronchovascular sheaths to the mediastinum. In this case the patient did not report in his history a recent blunt thoracic trauma and the initial suspicion of an allergic reaction has prevented physicians to immediately achieve the correct diagnosis.
Determination of cardiac size from chest roentgenograms following Skylab missions
NASA Technical Reports Server (NTRS)
Nicogossian, A. E.; Hoffler, G. W.; Johnson, R. L.; Gowen, R. J.
1974-01-01
Decreased cardiothoracic transverse diameter ratios following Mercury, Gemini and Apollo space flights have been reported previously. To evaluate further changes in cardiac size, standard posteroanterior chest films in systole and diastole were obtained before flight and within a few hours after recovery on each of the Skylab astronauts. Postflight chest X-rays were visually compared to the preflight roentgenograms for possible changes in pulmonary vasculature, lung parenchyma, bony or soft tissue structures. From these roentgenograms the following measurements were obtained: cardiac and thoracic transverse diameters, cardiothoracic transverse diameter ratio, cardiac area from the product of both diagonal diameters, cardiac silhouette area by planimetry, thoracic cage area and cardiothoracic area ratio. The postflight frontal cardiac silhouette sizes were significantly decreased when compared with the respective preflight values (P0.05 or 0.01). The observed changes are thought to be related to postflight decrease in the intracardiac chamber volume.
Unusual case of a lung abscess.
Musa, Duduzile; Godbole, Gauri; Chiodini, Peter L; Phillips, Russell
2013-04-16
A 56-year-old Caucasian lady presented with a short history of pleuritic chest pain on the background of a 2-month history of fever, chills, 10-kg weight loss and cough with brown sputum after a laparoscopic cholecystectomy. She had persistent eosinophilia and was diagnosed with a lung abscess as seen on chest x-ray. She did not respond to standard intravenous broad spectrum antibacterial medication and her chest CT scan showed a moderate pleural collection in continuity with the abscess. She also underwent bronchoscopy, the microscopy of the bronchial washings revealing eggs of the trematode Fasciola. The bacterial and fungal cultures of the washings were sterile. She had visited Turkey in the previous year but did not remember consuming any watercress or aquatic plants. She was successfully treated with two doses of the antiparasitic agent triclabendazole. Ectopic Fasciola can be a rare cause of a lung abscess.
Tension pneumothorax due to perforated colon.
Abdullah, Muhammad; Stonelake, Paul
2016-05-31
A very rare case of traumatic diaphragmatic hernia is reported in a 65-year-old woman who presented 46 years after her initial thoracoabdominal injury with tension faecopneumothorax caused by a perforated colon in the chest cavity. She presented in a critical condition with severe respiratory distress, sepsis and acute kidney injury. She had a long-standing history of bronchial asthma with respiratory complications and had experienced progressive shortness of breath for the past year. A recent CT scan had excluded the presence of a diaphragmatic hernia but showed a significantly raised left hemidiaphragm. On admission, chest X-rays showed a significantly raised left hemidiaphragm and mediastinal shift, but the possibility of a diaphragmatic hernia with strangulated bowel in the chest was not suspected until the patient was reviewed by the surgical and intensive care unit consultants the next morning and a repeat CT performed. She had a successful outcome after her emergency operation. 2016 BMJ Publishing Group Ltd.
Effective doses to patients undergoing thoracic computed tomography examinations.
Huda, W; Scalzetti, E M; Roskopf, M
2000-05-01
The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.
Bone suppression technique for chest radiographs
NASA Astrophysics Data System (ADS)
Huo, Zhimin; Xu, Fan; Zhang, Jane; Zhao, Hui; Hobbs, Susan K.; Wandtke, John C.; Sykes, Anne-Marie; Paul, Narinder; Foos, David
2014-03-01
High-contrast bone structures are a major noise contributor in chest radiographic images. A signal of interest in a chest radiograph could be either partially or completely obscured or "overshadowed" by the highly contrasted bone structures in its surrounding. Thus, removing the bone structures, especially the posterior rib and clavicle structures, is highly desirable to increase the visibility of soft tissue density. We developed an innovative technology that offers a solution to suppress bone structures, including posterior ribs and clavicles, on conventional and portable chest X-ray images. The bone-suppression image processing technology includes five major steps: 1) lung segmentation, 2) rib and clavicle structure detection, 3) rib and clavicle edge detection, 4) rib and clavicle profile estimation, and 5) suppression based on the estimated profiles. The bone-suppression software outputs an image with both the rib and clavicle structures suppressed. The rib suppression performance was evaluated on 491 images. On average, 83.06% (±6.59%) of the rib structures on a standard chest image were suppressed based on the comparison of computer-identified rib areas against hand-drawn rib areas, which is equivalent to about an average of one rib that is still visible on a rib-suppressed image based on a visual assessment. Reader studies were performed to evaluate reader performance in detecting lung nodules and pneumothoraces with and without a bone-suppression companion view. Results from reader studies indicated that the bone-suppression technology significantly improved radiologists' performance in the detection of CT-confirmed possible nodules and pneumothoraces on chest radiographs. The results also showed that radiologists were more confident in making diagnoses regarding the presence or absence of an abnormality after rib-suppressed companion views were presented
Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi
2015-01-01
The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (-50 to -6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies.
Hasegawa, Hiroaki; Sato, Masanori; Tanaka, Hiroshi
2015-01-01
The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (−50 to −6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies. PMID:26151914
Reicher, Joshua; Reicher, Danielle; Reicher, Murray
2007-06-01
Improper positioning of the endotracheal tube during intubation poses a serious health risk to patients. In one prospective study of 219 critically ill patients, 14% required endotracheal tube repositioning after intubation [Brunel et al. Chest 1989; 96: 1043-1045] While a variety of techniques are used to confirm proper tube placement, a chest X-ray is usually employed for definitive verification. Radio frequency identification (RFID) technology, in which an RFID reader emits and receives a signal from an RFID tag, may be useful in evaluating endotracheal tube position. RFID technology has already been approved for use in humans as a safe and effective tool in a variety of applications. The use of handheld RFID detectors and RFID tag-labeled endotracheal tubes could allow for easy and accurate bedside monitoring of endotracheal tube position, once initial proper placement is confirmed.
Edge map analysis in chest X-rays for automatic pulmonary abnormality screening.
Santosh, K C; Vajda, Szilárd; Antani, Sameer; Thoma, George R
2016-09-01
Our particular motivator is the need for screening HIV+ populations in resource-constrained regions for the evidence of tuberculosis, using posteroanterior chest radiographs (CXRs). The proposed method is motivated by the observation that abnormal CXRs tend to exhibit corrupted and/or deformed thoracic edge maps. We study histograms of thoracic edges for all possible orientations of gradients in the range [Formula: see text] at different numbers of bins and different pyramid levels, using five different regions-of-interest selection. We have used two CXR benchmark collections made available by the U.S. National Library of Medicine and have achieved a maximum abnormality detection accuracy (ACC) of 86.36 % and area under the ROC curve (AUC) of 0.93 at 1 s per image, on average. We have presented an automatic method for screening pulmonary abnormalities using thoracic edge map in CXR images. The proposed method outperforms previously reported state-of-the-art results.
[Solitary fibrous tumor of the pleura (SFTP) hidden in the pleural effusion].
Kołodziejski, Leszek; Dyczek, Sonia; Lobaziewicz, Wojciech
2006-01-01
The patient with a non-malignant type of solitary fibrous tumor of the pleura (SFTP) has been presented as an example; this tumor manifested itself in long-lasting pleural effusion. The tumor, submerged in the liquid, with the diameter of 16 cm, was invisible in standard and computer X-rays of the chest. The tumor was found and removed during the thoracotomy. The patient has been alive for 9 years, without symptoms of the disease since the operation was performed. 1. The source of one-sided exudation can be a non-malignant SFTP. 2. Tumor submerged in the liquid can be invisible on standard and computer pictures of the chest.
Straightened sternal wire causes iatrogenic pectus carinatum after cardiac surgery.
Thompson, Jess L; Teodori, Michael F
2013-03-01
Pectus carinatum is a protrusion deformity of the anterior chest wall that is most likely caused by a disproportionate growth of the costal cartilages compared with the remainder of the thoracic skeleton. A young boy had previously undergone corrective congenital heart operation, after which a prominent sternal protrusion was noted. During the past year, the protrusion had greatly increased in size and had become recurrently infected. Chest X-ray showed that a sternal wire, the ends of which were pointing toward the skin, had straightened. Operative intervention included removal of the offending wire, draining a chronic abscess, and shaving the protruding sternum so that it conformed to the rest of the sternum.
The rational clinical examination. Does this infant have pneumonia?
Margolis, P; Gadomski, A
1998-01-28
Acute lower respiratory tract illness is common among children seen in primary care. We reviewed the accuracy and precision of the clinical examination in detecting pneumonia in children. Although most cases are viral, it is important to identify bacterial pneumonia to provide appropriate therapy. Studies were identified by searching MEDLINE from 1982 to 1995, reviewing reference lists, reviewing a published compendium of studies of the clinical examination, and consulting experts. Observer agreement is good for most signs on the clinical examination. Each study was reviewed by 2 observers and graded for methodologic quality. There is better agreement about signs that can be observed (eg, use of accessory muscles, color, attentiveness; kappa, 0.48-0.66) than signs that require auscultation of the chest (eg, adventitious sounds; kappa, 0.3). Measurements of the respiratory rate are enhanced by counting for 60 seconds. The best individual finding for ruling out pneumonia is the absence of tachypnea. Chest indrawing, and other signs of increased work of breathing, increases the likelihood of pneumonia. If all clinical signs (respiratory rate, auscultation, and work of breathing) are negative, the chest x-ray findings are unlikely to be positive. Studies are needed to assess the value of clinical findings when they are used together.
Semi-automated location identification of catheters in digital chest radiographs
NASA Astrophysics Data System (ADS)
Keller, Brad M.; Reeves, Anthony P.; Cham, Matthew D.; Henschke, Claudia I.; Yankelevitz, David F.
2007-03-01
Localization of catheter tips is the most common task in intensive care unit imaging. In this work, catheters appearing in digital chest radiographs acquired by portable chest x-rays were tracked using a semi-automatic method. Due to the fact that catheters are synthetic objects, its profile does not vary drastically over its length. Therefore, we use forward looking registration with normalized cross-correlation in order to take advantage of a priori information of the catheter profile. The registration is accomplished with a two-dimensional template representative of the catheter to be tracked generated using two seed points given by the user. To validate catheter tracking with this method, we look at two metrics: accuracy and precision. The algorithms results are compared to a ground truth established by catheter midlines marked by expert radiologists. Using 12 objects of interest comprised of naso-gastric, endo-tracheal tubes, and chest tubes, and PICC and central venous catheters, we find that our algorithm can fully track 75% of the objects of interest, with a average tracking accuracy and precision of 85.0%, 93.6% respectively using the above metrics. Such a technique would be useful for physicians wishing to verify the positioning of catheter tips using chest radiographs.
The relationship between patient data and pooled clinical management decisions.
Ludbrook, G I; O'Loughlin, E J; Corcoran, T B; Grant, C
2013-01-01
A strong relationship between patient data and preoperative clinical decisions could potentially be used to support clinical decisions in preoperative management. The aim of this exploratory study was to determine the relationship between key patient data and pooled clinical opinions on management. In a previous study, panels of anaesthetists compared the quality of computer-assisted patient health assessments with outpatient consultations and made decisions on the need for preoperative tests, no preoperative outpatient assessment, possible postoperative intensive care unit/high dependency unit requirements and aspiration prophylaxis. In the current study, the relationship between patient data and these decisions was examined using binomial logistic regression analysis. Backward stepwise regression was used to identify independent predictors of each decision (at P >0.15), which were then incorporated into a predictive model. The number of factors related to each decision varied: blood picture (four factors), biochemistry (six factors), coagulation studies (three factors), electrocardiography (eight factors), chest X-ray (seven factors), preoperative outpatient assessment (17 factors), intensive care unit requirement (eight factors) and aspiration prophylaxis (one factor). The factor types also varied, but included surgical complexity, age, gender, number of medications or comorbidities, body mass index, hypertension, central nervous system condition, heart disease, sleep apnoea, smoking, persistent pain and stroke. Models based on these relationships usually demonstrated good sensitivity and specificity, with receiver operating characteristics in the following areas under curve: blood picture (0.75), biochemistry (0.86), coagulation studies (0.71), electrocardiography (0.90), chest X-ray (0.85), outpatient assessment (0.85), postoperative intensive care unit requirement (0.88) and aspiration prophylaxis (0.85). These initial results suggest modelling of patient data may have utility supporting clinicians' preoperative decisions.
Transarterial pacemaker lead implantation results in acute myocardial infarction.
Issa, Ziad F; Gill, John B
2010-11-01
We report a case of inadvertent transarterial implantation of dual-chamber pacemaker leads; the ventricular lead positioned across the aortic valve into the left ventricle and the atrial lead curving in the aortic root with the tip positioned into the left circumflex artery, resulting in acute myocardial infarction. The diagnosis was made based on the finding on the chest X-ray, surface ECG, and coronary angiography.
Pacemaker lead fracture associated with weightlifting: a report of two cases.
Deering, J A; Pederson, D N
1993-12-01
Two cases of pacemaker lead fracture associated with weight-lifting are presented. This is a rare association which has only recently been described in the literature. In both cases, the pacemaker lead was fractured between the clavicle and the first rib, suggesting crush injury. The chest X-ray, pacemaker telemetry with measurement of lead impedance, and pacemaker reprogramming were all helpful in management.
Manigandan, Gopalakrishnan; Venkatesh, Chandrasekaran; Gunasekaran, Dhandapani; Soundararajan, Palanisamy
2013-01-01
A five-year-old boy with acute on chronic ear discharge and fever was diagnosed to have tubercular otitis media (TOM) with Staphylococcus aureus co-infection. His chest X-ray was suggestive of miliary tuberculosis. The clinical presentation of the child with a brief review of the literature pertaining to the case is being discussed in this report.
Clinical Investigation Service Annual Research Progress Report Fiscal Year 1980,
1980-10-01
Capillary (Heelstick) and Central ( Venous ) 136 Total White Blood Cell Counts and Differentials in Normal Newborn Infants (0) PHYSICAL MEDICINE...Comparison of Capillary (Heelstick) and Central ( Venous ) Total White Blood Cell Counts and Differentials in Normal Newborn Infants PRINCIPAL INVESTIGATOR...tolerance tests with renal glycosuria shall be evaluated. Day 1: History , physical examination, routine CBC, chest x-ray, STS, regular hospital diet (300 gm
Loughlin, Michael T; Duncan, Timothy J
2012-04-01
A 58-year-old woman underwent outpatient colonoscopy with multiple cold forceps biopsy for evaluation of a presumptive diagnosis of ulcerative colitis. Six hours following the procedure, she developed subcutaneous crepitus and presented to the emergency department, where chest X-ray revealed pneumomediastinum and subcutaneous emphysema. Our case discusses this unusual complication of colonoscopy and its diagnosis and management.
Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method
NASA Astrophysics Data System (ADS)
Wu, Tao; Zhang, Juemin; Moore, Richard; Rafferty, Elizabeth; Kopans, Daniel; Meleis, Waleed; Kaeli, David
2004-05-01
A parallel reconstruction method, based on an iterative maximum likelihood (ML) algorithm, is developed to provide fast reconstruction for digital tomosynthesis mammography. Tomosynthesis mammography acquires 11 low-dose projections of a breast by moving an x-ray tube over a 50° angular range. In parallel reconstruction, each projection is divided into multiple segments along the chest-to-nipple direction. Using the 11 projections, segments located at the same distance from the chest wall are combined to compute a partial reconstruction of the total breast volume. The shape of the partial reconstruction forms a thin slab, angled toward the x-ray source at a projection angle 0°. The reconstruction of the total breast volume is obtained by merging the partial reconstructions. The overlap region between neighboring partial reconstructions and neighboring projection segments is utilized to compensate for the incomplete data at the boundary locations present in the partial reconstructions. A serial execution of the reconstruction is compared to a parallel implementation, using clinical data. The serial code was run on a PC with a single PentiumIV 2.2GHz CPU. The parallel implementation was developed using MPI and run on a 64-node Linux cluster using 800MHz Itanium CPUs. The serial reconstruction for a medium-sized breast (5cm thickness, 11cm chest-to-nipple distance) takes 115 minutes, while a parallel implementation takes only 3.5 minutes. The reconstruction time for a larger breast using a serial implementation takes 187 minutes, while a parallel implementation takes 6.5 minutes. No significant differences were observed between the reconstructions produced by the serial and parallel implementations.
[Clinical and etiologic study of 90 cases of chronic diarrhea].
Farfán Flores, G; Sánchez, G; Tello, R; Villanueva, G
1993-01-01
90 patients with chronic diarrhoea underwent this prospective study. They were seen in a private hospital of Lima during 1990 and 1991. According to a methodologic plan for determining sources and the diseases that originate chronic diarrhoea. In all patients hematologic, bioquimic, coprocultures, coproparasitologic exams were done, chest and intestinal transit X-rays. All underwent duodenal content culture. Colon X-ray in 25 cases; proctosigmoidoscopy in 14 and upper digestive endoscopy in 19 patients. Abdominal echography in 12 and TAC in 2 cases. The final results showed as determinant diseases for chronic diarrhoea, according to their frequency: enteroparasitosis (23.3%), functional digestive disorders (20.0%), intestinal bacterial overpopulation (15.5%) of unknown origin (8.8%), colon diverticulus (7.7%) proven and probably (5.5%), lactose intolerance (3.3%), diabetes mellitus (2.2%), and in one case (1.1%) the following: intestinal linfoma, pancreas malignancy, AIDS, colonic and deformation and megaloblastic anemia. The causes of chronic diarrhoea are several and multifactorals and in this study we prove the preeminence of the intestinal parasitosis, functional disorders and intestinal bacterial overpopulation and with less frequency other pathologies.
Kowada, Akiko
2011-12-01
Currently, an annual chest X-ray examination (CXR) for detection of active tuberculosis (TB) in employees aged ≥40 years is recommended in the guidelines of the Japan Industrial Safety and Health Law. Interferon-γ release assays are new alternatives to the tuberculin skin test for detecting Mycobacterium tuberculosis infection, with higher specificity than the tuberculin skin test and without cross-reactivity with the Bacille Calmette-Guérin vaccine. This study aimed to assess the cost-effectiveness of employee TB screening using QuantiFERON-TB Gold In-Tube (QFT) versus CXR. Markov models were constructed. The target population was a hypothetical cohort of immunocompetent 40-year-old individuals, using a societal perspective and a lifetime horizon. All costs and clinical benefits were discounted at a fixed annual rate of 3%. In a base-case analysis, the QFT strategy was the most cost-effective ($US 262.84; 22.87049 quality-adjusted life-years [QALYs]) compared with no screening ($448.38; 22.85452 QALYs) and CXR ($543.50; 22.85453 QALYs) [year 2009 values]. The QFT strategy is currently robust for screening Bacille Calmette-Guérin- vaccinated employees in Japan. There appears to be little role for CXR. These findings may be applicable to other countries in terms of choosing optimal TB screening for employees. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Nicholls, Judith; Gaskin, Pamela S; Ward, Justin; Areti, Yasodananda K
2016-12-01
We endeavor to assess the impact of introduction of guidelines for preoperative investigations (PIs) on anesthetic practices and costs and compare their efficacy to current practices. A prospective study. Queen Elizabeth Hospital, Barbados. Participants comprised all patients undergoing general, epidural, spinal, and regional anesthesia, with the exception of emergency cases or instances where an anesthesiologist was not required. Introduction of formal guidelines for preoperative investigations. The patterns of preoperative testing were assessed by audit, and this assessment was repeated postintervention. PI guidelines developed were presented to all surgical departments. For younger patients (<60 years), the mean number of tests decreased from 3.42±1.8 in the preguideline group to 2.89±1.98 in the postguideline group (P=.042). The total number of chest x-rays decreased by 14.8% (P=.012) and full blood counts by 7.6% (P=.036). The implementation of PI guidelines led to overall savings of US $7589 per 1000 patients, which is equivalent to (US $40,745.50 per annum). The most notable savings were due to decreased number of chest x-rays. PIs were performed routinely even in the absence of clinical indications. Our findings indicate that introduction of guidelines has reduced the level of preanesthetic investigations to some extent; nevertheless, further change is desirable. In addition, costs to the institution were decreased with no compromise to patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.
Rivas-Clemente, F P; Nácher-Conches, M; Corrillero-Martín, J; Vélez-Reyes, S; Huerta-Galindo, L
1999-10-31
To assess acceptability and adherence to a tuberculosis screening programme (TSP) in Maghrebi immigrants (MI). A descriptive crossover study. Primary health care service. MI residing in a periurban health district. All people who attended clinic for consultation at a primary care center were systematically recommended to be screened for tuberculosis. Individuals accomplished a questionnaire in arabic (with interpreter assistance) and were subjected to tuberculosis infection/illness screening tests till they were assigned one of the definitive diagnostic classes of the American Thoracic Society. 219 individuals were offered the TSP (sex ratio 6.2:1). 166 individuals (76.1%) accepted the test and kept their first appointment: 147 males (78.2%) versus 19 females (63.3%); difference in acceptance by gender was not significant (chi 2 = 3.14; p = 0.07). Fourteen individuals did not complete the study (8.6%): one did not attend clinic for Mantoux reading, four did not have the chest X-ray, three did not present themselves on their Mantoux reading, nor did they have the chest X-ray and, six did not deliver sputum samples (11.1% of the required samples). Six cases of TB were diagnosed. Given the special features of the MI (communication difficulties, illegal status, no fixed abode ...) acceptance and adherence to TSP are considered to be high. The diagnostic effectiveness, though considerable, was affected by the high number of individuals which did not deliver sputum samples. TSP directed to MI must have a specific design in order to facilitate acceptance and adherence.
Gonzales, Ralph; Aagaard, Eva M; Camargo, Carlos A; Ma, O John; Plautz, Mark; Maselli, Judith H; McCulloch, Charles E; Levin, Sara K; Metlay, Joshua P
2011-07-01
Antibiotics are commonly overused in adults seeking emergency department (ED) care for acute cough illness. To evaluate the effect of a point-of-care C-reactive protein (CRP) blood test on antibiotic treatment of acute cough illness in adults. A randomized controlled trial was conducted in a single urban ED in the United States. The participants were adults (age ≥ 18 years) seeking care for acute cough illness (≤ 21 days duration); 139 participants were enrolled, and 131 completed the ED visit. Between November 2005 and March 2006, study participants had attached to their medical charts a clinical algorithm with recommendations for chest X-ray study or antibiotic treatment. For CRP-tested patients, recommendations were based on the same algorithm plus the CRP level. There was no difference in antibiotic use between CRP-tested and control participants (37% [95% confidence interval (CI) 29-45%] vs. 31% [95% CI 23-39%], respectively; p = 0.46) or chest X-ray use (52% [95% CI 43-61%] vs. 48% [95% CI 39-57%], respectively; p = 0.67). Among CRP-tested participants, those with normal CRP levels received antibiotics much less frequently than those with indeterminate CRP levels (20% [95% CI 7-33%] vs. 50% [95% CI 32-68%], respectively; p = 0.01). Point-of-care CRP testing does not seem to provide any additional value beyond a point-of-care clinical decision support for reducing antibiotic use in adults with acute cough illness. Copyright © 2011 Elsevier Inc. All rights reserved.
Black pleural effusion due to pancreatic pseudocyst: A case report.
Guo, Feng; Wu, Junli; Peng, Yunpeng; Tu, Min; Xiao, Bin; Dai, Cuncai; Jiang, Kuirong; Gao, Wentao; Li, Qiang; Wei, Jishu; Chen, Jianmin; Xi, Chunhua; Lu, Zipeng; Miao, Yi
2017-12-01
Black pleural effusion (BPE) is an extremely uncommon type of pleural fluid, which can be due to infection, primary or metastatic malignancy, and hemorrhage. As reported in previous studies, BPE is also observed in some patients with pancreatic pseudocyst. We herein reported a case of a 14-year-old female patient who was admitted to our center with a history of cough for 1 and a half months and right chest pain for 1 month. Before this, she was consecutively hospitalized in 3 different hospitals due to the same symptoms. However, the previous treatments were ineffective due to the lack of a definitive diagnosis. Laboratory examination of the pleural effusion showed BPE with a high amylase concentration. Chest x-ray and computed tomography (CT) showed massive pleural effusion, more prominent in the right chest. CT and MRCP of the abdomen showed a cystic lesion located in the tail of the pancreas, which entered the chest cavity via an esophageal hiatal hernia. DIAGNOSES:: pancreatic pseudocyst. After confirming that the tumor was a pancreatic pseudocyst by intraoperative biopsy, internal drainage to the jejunum was performed. The postoperative recovery was rapid and without complications, and the final discharge diagnosis was idiopathic pancreatic pseudocyst (without history of pancreatitis or pancreatic injuries) with BPE of the right chest. This case demonstrates that massive BPE could present as a rare complication of pancreatic pseudocyst, and surgery is a potential treatment for such patients. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Murthy, S E; Chatterjee, F; Crook, A; Dawson, R; Mendel, C; Murphy, M E; Murray, S R; Nunn, A J; Phillips, P P J; Singh, Kasha P; McHugh, T D; Gillespie, S H
2018-05-21
Chest radiographs are used for diagnosis and severity assessment in tuberculosis (TB). The extent of disease as determined by smear grade and cavitation as a binary measure can predict 2-month smear results, but little has been done to determine whether radiological severity reflects the bacterial burden at diagnosis. Pre-treatment chest x-rays from 1837 participants with smear-positive pulmonary TB enrolled into the REMoxTB trial (Gillespie et al., N Engl J Med 371:1577-87, 2014) were retrospectively reviewed. Two clinicians blinded to clinical details using the Ralph scoring system performed separate readings. An independent reader reviewed discrepant results for quality assessment and cavity presence. Cavitation presence was plotted against time to positivity (TTP) of sputum liquid cultures (MGIT 960). The Wilcoxon rank sum test was performed to calculate the difference in average TTP for these groups. The average lung field affected was compared to log 10 TTP by linear regression. Baseline markers of disease severity and patient characteristics were added in univariable regression analysis against radiological severity and a multivariable regression model was created to explore their relationship. For 1354 participants, the median TTP was 117 h (4.88 days), being 26 h longer (95% CI 16-30, p < 0.001) in patients without cavitation compared to those with cavitation. The median percentage of lung-field affected was 18.1% (IQR 11.3-28.8%). For every 10-fold increase in TTP, the area of lung field affected decreased by 11.4%. Multivariable models showed that serum albumin decreased significantly as the percentage of lung field area increased in both those with and without cavitation. In addition, BMI and logged TTP had a small but significant effect in those with cavitation and the number of severe TB symptoms in the non-cavitation group also had a small effect, whilst other factors found to be significant on univariable analysis lost this effect in the model. The radiological severity of disease on chest x-ray prior to treatment in smear positive pulmonary TB patients is weakly associated with the bacterial burden. When compared against other variables at diagnosis, this effect is lost in those without cavitation. Radiological severity does reflect the overall disease severity in smear positive pulmonary TB, but we suggest that clinicians should be cautious in over-interpreting the significance of radiological disease extent at diagnosis.
Möhner, Matthias; Gellissen, Johannes; Marsh, James W; Gregoratto, Demetrio
2010-09-01
Lung cancer is a well-known effect of radon exposure in uranium mines. However, little is known about the induction of leukemia by radiation exposure in mines. Moreover, miners usually have occupational medical checkup programs that include chest x-ray examinations. Therefore, the aim of the present study was to re-examine leukemia risk among miners, taking into account exposure to x rays for diagnostic purposes. The data used were from a previously analyzed individually matched case-control study of former uranium miners in East Germany with 377 cases and 980 controls. Additionally, data on x-ray examinations were taken from medical records for most of the subjects. Finally, the absorbed dose to red bone marrow was calculated considering both occupational and diagnostic exposures. Using conditional logistic regression models, a moderately but not statistically significant elevated risk was seen in the dose category above 200 mGy for the combined dose from both sources [odds ratio (OR) = 1.33, 90% confidence interval (CI): (0.82-2.14)]. Ignoring the dose accumulated in the recent 20 y, the risk in the highest dose category (>105 mGy) was higher [OR = 1.77, 90% CI: (1.06-2.95)]. Ignoring diagnostic exposure yielded similar results. For the highest dose category (absorbed dose lagged by 20 y) the risk was more than doubled [OR = 2.64, 90% CI: (1.60-4.35)].
X-ray dark-field radiography facilitates the diagnosis of pulmonary fibrosis in a mouse model.
Hellbach, Katharina; Yaroshenko, Andre; Willer, Konstantin; Conlon, Thomas M; Braunagel, Margarita B; Auweter, Sigrid; Yildirim, Ali Ö; Eickelberg, Oliver; Pfeiffer, Franz; Reiser, Maximilian F; Meinel, Felix G
2017-03-23
The aim of this study was to evaluate whether diagnosing pulmonary fibrosis with projection radiography can be improved by using X-ray dark-field radiograms. Pulmonary X-ray transmission and dark-field images of C57Bl/6N mice, either treated with bleomycin to induce pulmonary fibrosis or PBS to serve as controls, were acquired with a prototype grating-based small-animal scanner. Two blinded readers, both experienced radiologists and familiar with dark-field imaging, had to assess dark-field and transmission images for the absence or presence of fibrosis. Furthermore readers were asked to grade their stage of diagnostic confidence. Histological evaluation of the lungs served as the standard of reference in this study. Both readers showed a notably higher diagnostic confidence when analyzing the dark-field radiographs (p < 0.001). Diagnostic accuracy improved significantly when evaluating the lungs in dark-field images alone (p = 0.02) or in combination with transmission images (p = 0.01) compared to sole analysis of absorption images. Interreader agreement improved from good when assessing only transmission images to excellent when analyzing dark-field images alone or in combination with transmission images. Adding dark-field images to conventional transmission images in a murine model of pulmonary fibrosis leads to an improved diagnosis of this disease on chest radiographs.
Stammers, David; Connolly, Bairbre; Brandão, Leonardo R; Zupanec, Sue; Gupta, Sumit
2017-07-01
Venous access device (VAD) occlusion from intraluminal thrombus is a common complication during childhood cancer treatment. Current practice at many institutions is to assess VAD position with a chest X-ray (CXR) prior to intraluminal administration of tissue plasminogen activator (tPA). We aimed to determine the utility of this practice. A retrospective chart review of children with newly diagnosed cancer with a VAD, treated at The Hospital for Sick Children between 2010 and 2011, was performed. Episodes of line occlusion were identified both by reviewing patient CXRs for indication and identifying tPA doses dispensed. These episodes were reviewed to determine whether CXR findings resulted in management other than tPA. Cases in which the X-ray resulted in a change in management were further reviewed to determine whether administration of tPA could have resulted in potential patient harm. A total of 330 patients with newly diagnosed cancer with VADs were identified. Eighty-five (25.8%) patients experienced 123 episodes of VAD occlusion. VAD occlusions occurred more frequently in patients with tunneled external central venous lines (16/39, 41.5%) and peripherally inserted central catheters (PICC) (27/73, 37.0%) versus PORT (42/216, 19.4%; P = 0.001). There were nine (8.1%) episodes of VAD occlusion evaluated with a CXR in which the findings led to a change in management other than administering tPA. In each case, multiple specialists independently concluded that administration of tPA would have been unlikely to cause patient harm. Routine CXRs prior to the administration of tPA for asymptomatic VAD occlusion can safely be omitted. © 2016 Wiley Periodicals, Inc.
Biosorbable poly-L-lactide rib-connecting pins may reduce acute pain after thoracotomy.
Iwasaki, A; Hamatake, D; Shirakusa, T
2004-02-01
Conventional thoracotomy is currently used as a standard procedure, and is often required to treat numerous diseases. Additionally, rib resections are occasionally required to maintain an adequate field of view for surgery. The benefits of using rib pins for chest closure following such procedures have not yet been established. This study sought to evaluate the usefulness of rib pins in reducing acute postoperative pain. Thirty-three consecutive patients with lung cancer underwent lobectomies using the posterolateral approach. The patients were rib-resected and reconstructed with two techniques: 21 patients with absorbable rib pins (ARP group) and 12 patients by ligation with absorbable sutures (LAS group). Intensity of pain was assessed during the 3 days immediately following surgery. The two groups were assessed using the visual analogue scale (VAS) as a pain scale, amounts consumed of patient-controlled analgesics (PCA), and additional chest x-rays. On the first day following surgery, the mean VAS intensity of the ARP group for patient motion was 2.71 +/- 2.14, compared to 5.33 +/- 2.99 in the LAS group. After three days, the mean score for the ARP group was 1.98 +/- 1.89, compared to 4.60 +/- 1.97 in the LAS group. Scores in the ARP group were significantly lower than in the LAS group one day and three days following thoracotomy. The LAS group (55.0 +/- 15.9 times) made more frequent requests than the ARP group (16.1 +/- 10.3 times). The PCA requirement was also significantly lower in the ARP group. Excessive derangement of the rib (grade 2) was found in one case (4.7 %) in the ARP group compared to five cases (41.6 %) in the LAS group. Rib shifts were seen in numerous cases in the LAS group compared to the ARP group as measured by chest x-rays. Use of absorbable rib pins reduced postoperative pain and may improve long-term prospects for the post-thoracotomy course.
Tracing contacts of TB patients in Malaysia: costs and practicality.
Atif, Muhammad; Sulaiman, Syed Azhar Syed; Shafie, Asrul Akmal; Ali, Irfhan; Asif, Muhammad
2012-01-01
Tuberculin skin testing (TST) and chest X-ray are the conventional methods used for tracing suspected tuberculosis (TB) patients. The purpose of the study was to calculate the cost incurred by Penang General Hospital on performing one contact tracing procedure using an activity based costing approach. Contact tracing records (including the demographic profile of contacts and outcome of the contact tracing procedure) from March 2010 until February 2011 were retrospectively obtained from the TB contact tracing record book. The human resource cost was calculated by multiplying the mean time spent (in minutes) by employees doing a specific activity by their per-minute salaries. The costs of consumables, Purified Protein Derivative vials and clinical equipment were obtained from the procurement section of the Pharmacy and Radiology Departments. The cost of the building was calculated by multiplying the area of space used by the facility with the unit cost of the public building department. Straight-line deprecation with a discount rate of 3% was assumed for the calculation of equivalent annual costs for the building and machines. Out of 1024 contact tracing procedures, TST was positive (≥10 mm) in 38 suspects. However, chemoprophylaxis was started in none. Yield of contact tracing (active tuberculosis) was as low as 0.5%. The total unit cost of chest X-ray and TST was MYR 9.23 (2.90 USD) & MYR 11.80 (USD 3.70), respectively. The total cost incurred on a single contact tracing procedure was MYR 21.03 (USD 6.60). Our findings suggest that the yield of contact tracing was very low which may be attributed to an inappropriate prioritization process. TST may be replaced with more accurate and specific methods (interferon gamma release assay) in highly prioritized contacts; or TST-positive contacts should be administered 6H therapy (provided that the chest radiography excludes TB) in accordance with standard protocols. The unit cost of contact tracing can be significantly reduced if radiological examination is done only in TST or IRGA positive contacts.
Dornase alpha compared to hypertonic saline for lung atelectasis in critically ill patients.
Youness, Houssein A; Mathews, Kathryn; Elya, Marwan K; Kinasewitz, Gary T; Keddissi, Jean I
2012-12-01
Despite the lack of randomized trials, nebulized Dornase alpha and hypertonic saline are used empirically to treat atelectasis in mechanically ventilated patients. Our objective was to determine the clinical and radiological efficacy of these medications as an adjunct to standard therapy in critically ill patients. Mechanically ventilated patients with new onset (<48 h) lobar or multilobar atelectasis were randomized into three groups: nebulized Dornase alpha, hypertonic (7%) saline or normal saline every 12 h. All patients received standard therapy, including chest percussion therapy, kinetic therapy, and bronchodilators. The primary endpoint was the change in the daily chest X-ray atelectasis score. A total of 33 patients met the inclusion criteria and were randomized equally into the three groups. Patients in the Dornase alpha group showed a reduction of 2.18±1.33 points in the CXR score from baseline to day 7, whereas patients in the normal saline group had a reduction of 1.00±1.79 points, and patients in the hypertonic saline group showed a score reduction of 1.09±1.51 points. Pairwise comparison of the mean change of the CXR score showed no statistical difference between hypertonic saline, normal saline, and dornase alpha. Airway pressures as well as oxygenation, expressed as PaO(2)/F(I)O(2) and time to extubation also were similar among groups. During the study period the rate of extubation was 54% (6/11), 45% (5/11), and 63% (7/11) in the normal saline, hypertonic saline, and Dornase alpha groups, respectively (p=0.09). No treatment related complications were observed. There was no significant improvement in the chest X-ray atelectasis score in mechanically ventilated patients with new onset atelectasis who were nebulized with Dornase alpha twice a day. Hypertonic saline was no more effective than normal saline in this population. Larger randomized control trials are needed to confirm our results.
Manigandan, Gopalakrishnan; Venkatesh, Chandrasekaran; Gunasekaran, Dhandapani; Soundararajan, Palanisamy
2013-01-01
A five-year-old boy with acute on chronic ear discharge and fever was diagnosed to have tubercular otitis media (TOM) with Staphylococcus aureus co-infection. His chest X-ray was suggestive of miliary tuberculosis. The clinical presentation of the child with a brief review of the literature pertaining to the case is being discussed in this report. PMID:23599614
Crozer-Chester Medical Center Burn Research Project
2013-09-01
description of findings reported for CT scans, echocardiograms, cardiac catheterizations , chest x-ray reports, and measurements of central venous pressure...epithelial autografts (CEA) in patients with massive burn injuries. Central venous catheter exchange strategies in patients with acute burn injury at...had complete data. Culture data were stratified by type: sputum (SCx) (5.4 ±4.7 Cx/Patient), central venous catheter (CVCx) (2.1 ±2.4 Cx/Patient
Anterior mediastinal haematoma and left haemothorax on well-controlled oral anticoagulant therapy.
Abaskaron, M.; Peterson, G.; Huang, T. Y.
1983-01-01
An anterior mediastinal haematoma and left haemothorax developed in a hypertensive diabetic patient on oral anticoagulant therapy. This occurred in spite of well-controlled anticoagulation and the absence of other evidence of systemic bleeding. Angiography and daily chest X-ray follow-up were not only sufficient to confirm the diagnosis, but also avoided hazardous interventional procedures. Images Fig. 1a Fig. 1b PMID:6844193
Fast tomosynthesis for lung cancer detection using the SBDX geometry
NASA Astrophysics Data System (ADS)
Fahrig, Rebecca; Pineda, Angel R.; Solomon, Edward G.; Leung, Ann N.; Pelc, Norbert J.
2003-06-01
Radiology-based lung-cancer detection is a high-contrast imaging task, consisting of the detection of a small mass of tissue within much lower density lung parenchyma. This imaging task requires removal of confounding image details, fast image acquisition (< 0.1 s for pericardial region), low dose (comparable to a chest x-ray), high resolution (< 0.25 mm in-plane) and patient positioning flexibility. We present an investigation of tomosynthesis, implemented using the Scanning-Beam Digital X-ray System (SBDX), to achieve these goals. We designed an image-based computer model of tomosynthesis using a high-resolution (0.15-mm isotropic voxels), low-noise CT volume image of a lung phantom, numerically added spherical lesions and convolution-based tomographic blurring. Lesion visibility was examined as a function of half-tomographic angle for 2.5 and 4.0 mm diameter lesions. Gaussian distributed noise was added to the projected images. For lesions 2.5 mm and 4.0 mm in diameter, half-tomographic angles of at least 6° and 9° respectively were necessary before visualization of the lesions improved. The addition of noise for a dose equivalent to 1/10 that used for a standard chest radiograph did not significantly impair lesion detection. The results are promising, indicating that lung-cancer detection using a modified SBDX system is possible.
Epidemiology of Echinococcus granulosus infection in the central Peruvian Andes.
Moro, P. L.; McDonald, J.; Gilman, R. H.; Silva, B.; Verastegui, M.; Malqui, V.; Lescano, G.; Falcon, N.; Montes, G.; Bazalar, H.
1997-01-01
The prevalence of human, canine, and ovine echinococcosis was determined in an endemic area of the Peruvian Andes where control programmes have not been operational since 1980. Prevalence of infection in humans was determined using portable ultrasound, chest X-rays, and an enzyme-linked immunoelectrotransfer blot (EITB) assay. Canine and ovine echinococcal prevalence was determined by microscopic stool examinations following arecoline purging for tapeworm detection and by examination of the viscera from slaughtered livestock animals, respectively. The prevalence among 407 humans surveyed was 9.1%. The frequency of disease in the liver, lung, and in both organs was 3.4%, 2.0%, and 0.2%, respectively. Portable ultrasound or portable chest X-ray has shown that, compared to adults, children under 11 years had significantly higher seropositive rates without evidence of hydatid disease (P < 0.05). Among the 104 dogs inspected for echinococcus after arecoline purging, 33 (32%) were positive for adult tapeworms. Among the 117 sheep slaughtered at the local abattoir, 102 (87%) had hydatid cysts. The prevalence of human hydatidosis in this endemic area of Peru is one of the highest in the world and nearly five times higher than previously reported in 1980. An increase in echinococcosis prevalence may result after premature cessation of control programmes. PMID:9509628
Trenholme, Adrian A; Best, Emma J; Vogel, Alison M; Stewart, Joanna M; Miller, Charissa J; Lennon, Diana R
2017-06-01
To describe respiratory virus detection in children under 2 years of age in a population admitted with lower respiratory infection and to assess correlation with measures of severity. Nasopharyngeal aspirates from infants admitted with lower respiratory tract infection (n = 1645) over a 3-year time period were tested by polymerase chain reaction. We collected epidemiological and clinical data on all children. We assessed the correlation of presence of virus with length of hospital stay, intensive care admission and consolidation on chest X-ray. Of the children admitted 34% were Maori, 43% Pacific and 75% lived in areas in the bottom quintile for socio-economic deprivation. A virus was found in 94% of those tested including 30% with multiple viruses. Picornavirus was present in 59% including 34% as the sole virus. Respiratory syncytial virus was found in 39%. Virus co-detection was not associated with length of stay, chest X-ray changes or intensive care unit admission. In this disadvantaged predominately Maori and Pacific population, picornavirus is commonly found as a sole virus, respiratory syncytial virus is frequent but immunisation preventable influenza is infrequent. We did not find that co-detection of viruses was linked to severity. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
Miyamoto, Atsushi; Tsuboi, Eiyasu; Takaya, Hisashi; Sugino, Keishi; Sakamoto, Susumu; Kawabata, Masateru; Kishi, Kazuma; Narui, Koji; Homma, Sakae; Nakatani, Tatsuo; Nakata, Koichiro; Yoshimura, Kunihiko
2006-08-01
Some microbes, including the Bacteroides species, Staphylococcus aureus and Streptococcus milleri groups, can cause pulmonary abscess. Haemophilus parainfluenzae is usually categorized as one of the normal flora which colonizes in the ears and the nasopharynx, and it has been long considered that H. parainfluenzae has little pathogenicity in the lower respiratory tract and lung parenchymal. In this report, we present a case of pulmonary abscess caused by both H. parainfluenzae and Streptococcus intermedius. The patient was a 75-year-old man who had had total esophageo-gastrectomy because of esophageal cancer. He presented with purulent sputum, and chest X-ray film showed a dense consolidation in the right upper lung field. CT-guided transcutaneous fine needle aspiration was performed as a diagnostic procedure. Since both H. parainfluenzae and S. intermedius had been isolated from the lesion, pulmonary abscess caused by these two pathogens was diagnosed. The patient was treated with panipenem/betamipron, and his symptoms and pulmonary infiltrates on the chest X-ray film improved thereafter. So far, very few cases have been reported in which H. parainfluenzae caused lower respiratory tract infection. Although S. intermedius is known as one of the pathogens of pulmonary abscess, it is possible that H. parainfluenzae could also be pathogenic in infectious diseases of the lung.
Ward, Rebecca; Carroll, William D; Cunningham, Paula; Ho, Sheng-Ang; Jones, Mary; Lenney, Warren; Thompson, David
2017-01-01
Objectives Cumulative radiation exposure is associated with increased risk of malignancy. This is important in cystic fibrosis (CF) as frequent imaging is required to monitor disease progression and diagnose complications. Previous estimates of cumulative radiation are outdated as the imaging was performed on older equipment likely to deliver higher radiation. Our objectives were to determine the radiation dose delivered to children during common radiological investigations using modern equipment and to identify the number of such investigations performed in a cohort of children with CF to calculate their cumulative radiation exposure. Design, setting and participants Data including age at investigation and radiation exposure measured as estimated effective dose (EED) were collected on 2827 radiological studies performed on children at one UK paediatric centre. These were combined with the details of all radiological investigations performed on 65 children with CF attending the same centre to enable calculation of each child’s cumulative radiation exposure. Results The mean EED for the common radiological investigations varied according to age. The range was 0.01–0.02 mSv for chest X-rays, 0.03–0.11 mSv for abdominal X-rays, 0.57–1.69 mSv for CT chest, 2.9–3.9 mSv for abdominal and pelvic CT, 0.20–0.21 mSv for sinus CT and 0.15–0.52 mSv for fluoroscopy-guided procedures. The mean EED was three to five times higher for helical compared with axial chest CT scans. The mean annual cumulative EED for our cohort of children with CF was 0.15 mSv/year with an estimated cumulative paediatric lifetime EED (0–18 years) of 3.5 mSv. Conclusions This study provides up-to-date estimations of the radiation exposure when using common radiological investigations. These doses and the estimates of cumulative radiation exposure in children with CF are lower than previously reported. This reflects the reduced EED associated with modern equipment and the use of age-specific scanning protocols. PMID:28827272
Tsao, Yu-Chung; Liu, Su-Hsun; Tzeng, I-Shiang; Hsieh, Tsung-Han; Chen, Jau-Yuan; Luo, Jiin-Chyuan John
2017-03-01
Silicosis remains the most prevalent occupational disease worldwide. There have been no specific studies focusing on the association between exposure settings at work and the clinical severity in silicosis patients. In this study, we describe and compare the clinical characteristics and silicosis-associated exposure history at work among workers from several types of ceramic production facilities in Taiwan. We reviewed the medical records of 221 patients who were first diagnosed with silicosis at the Occupational Medicine Clinic of Northern Taiwan in 2012. For each patient, we collected data on demographic characteristics, smoking habits, working history, duration of exposure, and years on the first relevant job. We also retrieved clinical reports of the pulmonary function test and the baseline chest radiography used for silicosis staging. As compared to other ceramic workers, sanitary ceramic workers had a worse X-ray type (p=0.044), more advanced age (p<0.001), longer working duration (p=0.029), and a higher proportion of starting the first relevant job prior to the year 1975 (p=0.003). However, after adjusting for age, work duration, and an initial occupational exposure prior to 1975, sanitary ceramic workers showed a comparable risk for worse X-ray findings to other ceramic workers (adjusted odds ratio=1.18, p=0.704). Results of multivariable regression models on individual lung function parameter also suggested comparably impaired lung function tests between sanitary and other ceramic workers (p>0.05). In this study, we found that sanitary ceramic workers were at a similar risk to other ceramic workers for moderate to severe silicosis when older age and longer working duration were accounted for. Copyright © 2016. Published by Elsevier B.V.
Eke-Usim, Angela C.; Rogers, Mary A.M.; Gibson, Kristen E.; Crnich, Christopher; Mody, Lona
2016-01-01
Objectives To evaluate the use of diagnostic testing prior to treating an infection in nursing home (NH) residents with indwelling devices suspected of having a urinary tract infection (UTI) or pneumonia. Design Prospective longitudinal study nested within a randomized trial Setting Six NHs in Southeast Michigan Participants 162 NH residents with an indwelling urinary catheter and/or enteral feeding tube with 695 follow-up visits [189/695 (28%) visits with an infection]. Measurements Patient-specific clinical and demographic data—including information on incident infections, antibiotic use, and results of diagnostic tests—were obtained at study enrollment, after 14 days, and monthly thereafter for up to one year. Results : More than half (100/162 [62%]) of NH residents with indwelling devices had an incident infection requiring antibiotics, with substantial variations between NHs. Besides presence of infection-specific symptoms, change in function was a significant predictor for ordering a chest x-ray to detect pneumonia (OR = 1.7; P = 0.01). Similarly, change in mentation was a significant predictor for ordering a UA (OR = 1.9; P = 0.02), chest x-ray (OR = 3.3; P < 0.01), and blood culture (OR = 2.3; P = 0.02). Empiric antibiotic use before having laboratory data occurred in 50 of 233 suspected UTI (21.5%) and 16 of 53 (30.2%) suspected pneumonia. Antibiotics were used in 17% of visits without documented clinical or laboratory evidence of infection. Conclusion In this study nested within a cluster randomized trial and using data from control sites, we show that constitutional symptoms such as change in function and mentation commonly lead to diagnostic testing with subsequent antibiotic prescribing. Antibiotic use often continues despite negative test results and should be a target for future interventions. PMID:27655061
Danno, Katsura; Komukai, Jun; Yoshida, Hideki; Matsumoto, Kenji; Koda, Shinichi; Terakawa, Kazuhiko; Iso, Hiroyasu
2013-01-01
To investigate the association between the economic recession and the detection of advanced cases of pulmonary tuberculosis in Osaka city from 2007 to 2009. A repeated cross-sectional study. Osaka city has been the highest tuberculosis burden area in Japan. After the previous global financial crisis, the unemployment rate in Osaka prefecture has deteriorated from 5.3% in 2008 to 6.6% in 2009. During the study period, 3406 pulmonary tuberculosis cases were enrolled: 2530 males and 876 females; 1546 elderly cases (65 years and above) and 1860 young cases (under 65 years); 417 homeless cases and 2989 non-homeless cases. Patients' information included the sex, age, registry, health insurances, places of detection, sputum smear test results, patients' delay, doctors' delay and the grade of chest x-ray findings. They were statistically analysed between 2007 and 2008, two years before and just before the financial crisis, and between 2008 and 2009, just before and after the financial crisis. The total numbers of pulmonary tuberculosis cases were 1172 in 2007, 1083 in 2008 and 1151 in 2009. In health examinations for non-homeless people, higher number of cases in 2009 were sputum smear positive, had respiratory symptoms and showed advanced disease in chest x-rays than those in 2008, with a longer patients' delay. On the contrary, in health examination for homeless people, fewer cases of advanced pulmonary tuberculosis were found in 2009 than in 2008, with a shorter patients' delay. In clinical examinations, there was no trend towards a difference between non-homeless and homeless people. Although homeless people might be protected by public assistance, tuberculosis prevention and control need to be reinforced for the non-homeless population after the financial crisis.
Goldwasser, Deborah L; Kimmel, Marek
2013-01-01
The effectiveness of population-wide lung cancer screening strategies depends on the underlying natural course of lung cancer. We evaluate the expected stage distribution in the Mayo CT screening study under an existing simulation model of non-small cell lung cancer (NSCLC) progression calibrated to the Mayo lung project (MLP). Within a likelihood framework, we evaluate whether the probability of 5-year NSCLC survival conditional on tumor diameter at detection depends significantly on screening detection modality, namely chest X-ray and computed tomography. We describe a novel simulation framework in which tumor progression depends on cellular proliferation and mutation within a stem cell compartment of the tumor. We fit this model to randomized trial data from the MLP and produce estimates of the median radiologic size at the cure threshold. We examine the goodness of model fit with respect to radiologic tumor size and 5-year NSCLC survival among incident cancers in both the MLP and Mayo CT studies. An existing model of NSCLC progression under-predicts the number of advanced-stage incident NSCLCs among males in the Mayo CT study (p-value = 0.004). The probability of 5-year NSCLC survival conditional on tumor diameter depends significantly on detection modality (p-value = 0.0312). In our new model, selected solution sets having a median tumor diameter of 16.2-22.1 mm at cure threshold among aggressive NSCLCs predict both MLP and Mayo CT outcomes. We conclude that the median lung tumor diameter at cure threshold among aggressive NSCLCs in male smokers may be small (<20 mm). Copyright © 2012 UICC.
Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae
The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging qualitymore » was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)« less
Kerosene poisoning in children in Iraq.
Nagi, N. A.; Abdulallah, Z. A.
1995-01-01
One hundred and three children with kerosene poisoning were studied. The majority of the patients were under five years of age and included a newborn baby. More patients were seen in spring and fewer in winter months. Most of the patients were children of poor families living in overcrowded conditions. Negligence and ignorance were the main causes of poisoning. Respiratory and central nervous systems were mainly involved. Chest X-ray abnormalities were frequently seen. The patients were treated symptomatically. Only one patient died, he had been in a coma on admission to the hospital. All other patients had rapid and complete recoveries. PMID:7567734
[A case of lung abscess during chemotherapy for testicular tumor].
Hayashi, Yujiro; Miyago, Naoki; Takeda, Ken; Yamaguchi, Yuichiro; Nakayama, Masashi; Arai, Yasuyuki; Kakimoto, Ken-ichi; Nishimura, Kazuo
2014-05-01
32-year-old man was seen in a clinic because of prolonged cough and slight-fever. Chest X-ray showed multiple pulmonary nodules, and multiple lung and mediastinal lymph node metastases from right testicular tumor was suspected by positron emission tomography/CT (PET/CT) scan. He was diagnosed with right testicular germ cell tumor (embryonal carcinoma + seminoma, pT2N1M1b), and classified into the intermediate risk group according to International Germ Cell Cancer Collaborative Group. He underwent 4 cycles of chemotherapy with bleomycin, etoposide and cisplatin (BEP therapy). During BEP therapy, sputum with foul odor appeared and chest CT scan revealed lung abscess with a necrotic lesion of metastatic tumor. The lung abscess was treated successfully with antibiotics.
Severe acute respiratory syndrome in a doctor working at the Prince of Wales Hospital.
Wong, R S M
2003-06-01
Severe acute respiratory syndrome is a new disease that is highly contagious and is spreading in the local community and worldwide. This report is of a hospital medical officer with severe acute respiratory syndrome. He presented with sudden onset of fever, chills, myalgia, headache, and dizziness in early March 2003. He developed progressive respiratory symptoms and bilateral pulmonary infiltrates during the second week of his illness. Blood tests showed lymphopenia, mild thrombocytopenia, and prolonged activated partial thromboplastin time with normal d-dimer level. His chest condition gradually responded to ribavirin and corticosteroids, and serial chest X-ray showed resolving pulmonary infiltrates. The importance of early diagnosis lies in the potential for early treatment, leading to better response.
Pulmonary nocardiosis in patients with connective tissue disease: A report of two cases
Hagiwara, Shinya; Tsuboi, Hiroto; Hagiya, Chihiro; Yokosawa, Masahiro; Hirota, Tomoya; Ebe, Hiroshi; Takahashi, Hiroyuki; Ogishima, Hiroshi; Asashima, Hiromitsu; Kondo, Yuya; Umeda, Naoto; Suzuki, Takeshi; Hitomi, Shigemi; Matsumoto, Isao; Sumida, Takayuki
2014-01-01
Summary Reported here are 2 patients with connective tissue disease who developed pulmonary nocardiosis. Case 1 involved a 73-year-old man with malignant rheumatoid arthritis treated with prednisolone 25 mg/day. Chest X-rays revealed a pulmonary cavity and bronchoscopy detected Nocardia species. The patient was successfully treated with trimethoprim/sulfamethoxazole. Case 2 involved a 41-year-old woman with systemic lupus erythematosus. The patient received remission induction therapy with 50 mg/day of prednisolone and tacrolimus. Six weeks later, a chest CT scan revealed a pulmonary cavity; bronchoscopy resulted in a diagnosis of pulmonary nocardiosis. The patient had difficulty tolerating trimethoprim/sulfamethoxazole, so she was switched to and successfully treated with imipenem/cilastatin and amikacin. PMID:25343123
[A Patient with a Wedge-shaped Pulmonary Lesion Associated with Streptococcus parasanguinis].
Miyamoto, Hiroya; Gomi, Harumi; Ishioka, Haruhiko; Shirokawa, Taijiro
2016-05-01
An 84-year-old man was admitted to our hospital with bloody sputum. He was found to have a right lower lobe wedge-shaped nodular lesion with chest X-ray and computed tomography of the chest. Ceftriaxone and minocycline were started empirically based on a working diagnosis of community-acquired pneumonia. Streptococcus parasanguinis was isolated with sputum cultures obtained on three consecutive days and was identified based on its biochemical properties. S. parasanguinis is a member of the sanguinis group of viridans Streptococci. It is known as a causative pathogen for endocarditis. There are very few reports of S. parasanguinis associated with pulmonary infections. The present report describes the association of S. parasanguinis with a wedge-shaped nodular lesion in the lungs.
Diagnosis of pneumothorax using a microwave-based detector
NASA Astrophysics Data System (ADS)
Ling, Geoffrey S. F.; Riechers, Ronald G., Sr.; Pasala, Krishna M.; Blanchard, Jeremy; Nozaki, Masako; Ramage, Anthony; Jackson, William; Rosner, Michael; Garcia-Pinto, Patricia; Yun, Catherine; Butler, Nathan; Riechers, Ronald G., Jr.; Williams, Daniel; Zeidman, Seth M.; Rhee, Peter; Ecklund, James M.; Fitzpatrick, Thomas; Lockhart, Stephen
2001-08-01
A novel method for identifying pneumothorax is presented. This method is based on a novel device that uses electromagnetic waves in the microwave radio frequency (RF) region and a modified algorithm previously used for the estimation of the angle of arrival of radar signals. In this study, we employ this radio frequency triage tool (RAFT) to the clinical condition of pneumothorax, which is a collapsed lung. In anesthetized pigs, RAFT can detect changes in the RF signature from a lung that is 20 percent or greater collapsed. These results are compared to chest x-ray. Both studies are equivalent in their ability to detect pneumothorax in pigs.
Sonawane, A U; Shirva, V K; Pradhan, A S
2010-02-01
Skin entrance doses (SEDs) were estimated by carrying out measurements of air kerma from 101 X-ray machines installed in 45 major and selected hospitals in the country by using a silicon detector-based dose Test-O-Meter. 1209 number of air kerma measurements of diagnostic projections for adults have been analysed for seven types of common diagnostic examinations, viz. chest (AP, PA, LAT), lumbar spine (AP, LAT), thoracic spine (AP, LAT), abdomen (AP), pelvis (AP), hip joints (AP) and skull (PA, LAT) for different film-screen combinations. The values of estimated diagnostic reference levels (DRLs) (third quartile values of SEDs) were compared with guidance levels/DRLs of doses published by the IAEA-BSS-Safety Series No. 115, 1996; HPA (NRPB) (2000 and 2005), UK; CRCPD/CDRH (USA), European Commission and other national values. The values of DRLs obtained in this study are comparable with the values published by the IAEA-BSS-115 (1996); HPA (NRPB) (2000 and 2005) UK; EC and CRCPD/CDRH, USA including values obtained in previous studies in India.
al-Rifaie, Mohammad Majid; Aber, Ahmed; Hemanth, Duraiswamy Jude
2015-12-01
This study proposes an umbrella deployment of swarm intelligence algorithm, such as stochastic diffusion search for medical imaging applications. After summarising the results of some previous works which shows how the algorithm assists in the identification of metastasis in bone scans and microcalcifications on mammographs, for the first time, the use of the algorithm in assessing the CT images of the aorta is demonstrated along with its performance in detecting the nasogastric tube in chest X-ray. The swarm intelligence algorithm presented in this study is adapted to address these particular tasks and its functionality is investigated by running the swarms on sample CT images and X-rays whose status have been determined by senior radiologists. In addition, a hybrid swarm intelligence-learning vector quantisation (LVQ) approach is proposed in the context of magnetic resonance (MR) brain image segmentation. The particle swarm optimisation is used to train the LVQ which eliminates the iteration-dependent nature of LVQ. The proposed methodology is used to detect the tumour regions in the abnormal MR brain images.
Direction of an initial saccade depends on radiological expertise
NASA Astrophysics Data System (ADS)
Pietrzyk, Mariusz W.; McEntee, Mark F.; Evanoff, Michael E.; Brennan, Patrick C.; Mello-Thoms, Claudia R.
2014-03-01
Purpose: To evaluate the role of radiographic details in global impression of chest x-ray images viewed by experts in thoracic and non-thoracic domains. Materials and Methods: The study was approved by IRB. Five thoracic and five non-thoracic radiologists participated in two tachistoscopic (one low pass and one with the entire frequency spectrum, each lasting 270 ms) each containing 50 PA chest radiographs with 50% prevalence of pulmonary nodule. Eye movements were monitored in order to evaluate a pre-saccade shift of visual attention, saccade latency, decision time and the time to first fixation on a pulmonary nodule. Results: Thoracic radiologists showed significantly higher pre-saccadic shift of visual attention towards pulmonary nodules once using the full frequency spectrum (p < 0.05). An initial saccade orientation made by these radiologists on full resolution images correlated at significant level with their confidence ranking of pulmonary nodules (ρ = -0.387, p < 0.001). Conclusions: Thoracic radiologists benefited from high spatial frequency appearance during a rapid presentation of chest radiograph by allocating pre-saccade attention towards pulmonary nodules. This behavior correlated with a higher number of correct decisions, followed by higher confidence in the decisions made, and briefer reaction times.
Pneumothorax detection in chest radiographs using convolutional neural networks
NASA Astrophysics Data System (ADS)
Blumenfeld, Aviel; Konen, Eli; Greenspan, Hayit
2018-02-01
This study presents a computer assisted diagnosis system for the detection of pneumothorax (PTX) in chest radiographs based on a convolutional neural network (CNN) for pixel classification. Using a pixel classification approach allows utilization of the texture information in the local environment of each pixel while training a CNN model on millions of training patches extracted from a relatively small dataset. The proposed system uses a pre-processing step of lung field segmentation to overcome the large variability in the input images coming from a variety of imaging sources and protocols. Using a CNN classification, suspected pixel candidates are extracted within each lung segment. A postprocessing step follows to remove non-physiological suspected regions and noisy connected components. The overall percentage of suspected PTX area was used as a robust global decision for the presence of PTX in each lung. The system was trained on a set of 117 chest x-ray images with ground truth segmentations of the PTX regions. The system was tested on a set of 86 images and reached diagnosis accuracy of AUC=0.95. Overall preliminary results are promising and indicate the growing ability of CAD based systems to detect findings in medical imaging on a clinical level accuracy.
NASA Astrophysics Data System (ADS)
Moore, C. S.; Wood, T. J.; Saunderson, J. R.; Beavis, A. W.
2015-12-01
This work assessed the appropriateness of the signal-to-noise ratio improvement factor (KSNR) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients = 80). The KSNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. KSNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and KSNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of -0.93 (p = 0.015) was found for lung, a coefficient (R) of -0.95 (p = 0.46) was found for spine, and a coefficient (R) of -0.85 (p = 0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. KSNR increases with tube voltage but VGAS decreases. Medical physicists should use the KSNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely.
Modeling of photocurrent and lag signals in amorphous selenium x-ray detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siddiquee, Sinchita; Kabir, M. Z., E-mail: kabir@encs.concordia.ca
2015-07-15
A mathematical model for transient photocurrent and lag signal in x-ray imaging detectors has been developed by considering charge carrier trapping and detrapping in the energy distributed defect states under exponentially distributed carrier generation across the photoconductor. The model for the transient and steady-state carrier distributions and hence the photocurrent has been developed by solving the carrier continuity equation for both holes and electrons. The residual (commonly known as lag signal) current is modeled by solving the trapping rate equations considering the thermal release and trap filling effects. The model is applied to amorphous selenium (a-Se) detectors for both chestmore » radiography and mammography. The authors analyze the dependence of the residual current on various factors, such as x-ray exposure, applied electric field, and temperature. The electron trapping and detrapping mostly determines the residual current in a-Se detectors. The lag signal is more prominent in chest radiographic detector than in mammographic detectors. The model calculations are compared with the published experimental data and show a very good agreement.« less
Aerobic capacity and its correlates in patients with ankylosing spondylitis.
Hsieh, Lin-Fen; Wei, James Cheng-Chung; Lee, Hsin-Yi; Chuang, Chih-Cheng; Jiang, Jiunn-Song; Chang, Kae-Chwen
2016-05-01
To evaluate aerobic capacity in patients with ankylosing spondylitis (AS) and determine possible relationships between aerobic capacity, pulmonary function, and disease-related variables. Forty-two patients with AS and 42 healthy controls were recruited in the study. Descriptive data, disease-related variables (grip strength, lumbosacral mobility, occiput-to-wall distance, chest expansion, finger-to-floor distance, Bath Ankylosing Spondylitis Disease Activity Index, Bath Ankylosing Spondylitis Functional Index (BASFI), Bath Ankylosing Spondylitis Global Score, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) and hemoglobin), and chest and thoracic spine x-rays were collected in each patient with AS. All subjects took standard pulmonary function and exercise tolerance tests, and forced vital capacity (FVC) and aerobic capacity were recorded. Both aerobic capacity and FVC in patients with AS were significantly lower than those in normal subjects (P < 0.05). AS patients with BASFI scores of < 3 or BASDI scores of < 4 had a higher aerobic capacity. There was significant correlation between aerobic capacity, vital capacity, chest expansion, Schober's test, cervical range of motion, and BASFI in patients with AS. Neither aerobic capacity nor vital capacity correlated with disease duration, ESR, CRP, and hemoglobin. Significantly reduced aerobic capacity and FVC were observed in patients with AS, and there was significant correlation between aerobic capacity, vital capacity, chest expansion, and BASFI. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Are all after-hours diagnostic imaging appropriate? An Australian Emergency Department pilot study.
Gardiner, Fergus William; Zhai, Shaun
2016-12-01
This study was aimed at determining the extent to which after-hours diagnostic imaging is appropriate within the case hospital's Emergency Department. This was amid growing concerns of the inappropriateness of some medical investigations within the Australian health-care system. After-hours referral data and patient notes were used in reviewing the clinical case. Diagnostic imaging was deemed appropriate if reflective of clinical guidelines, and if not reflective, whether the investigation changed the patient's ongoing management. Results indicated that 96.37% of after-hours diagnostic imaging adhered to clinical guidelines and was appropriately requested, with 95.85% changing the ongoing management of the patient. The most sought after diagnostic imaging procedures were Chest X-Ray (30.83%), and CT Brain (16.58%), with 99.16% and 98.44 appropriateness respectively. Chest pain (14.49%) and motor vehicle accidents (8.12%) were the leading reason for ordering after-hours imaging. This study provided an Emergency Department example as it relates to after-hours diagnostic imaging appropriateness. This study found that most after-hours referrals were appropriate.
de Lesquen, Henri; Avaro, Jean-Philippe; Gust, Lucile; Ford, Robert Michael; Beranger, Fabien; Natale, Claudia; Bonnet, Pierre-Mathieu; D'Journo, Xavier-Benoît
2015-03-01
This review aims to answer the most common questions in routine surgical practice during the first 48 h of blunt chest trauma (BCT) management. Two authors identified relevant manuscripts published since January 1994 to January 2014. Using preferred reporting items for systematic reviews and meta-analyses statement, they focused on the surgical management of BCT, excluded both child and vascular injuries and selected 80 studies. Tension pneumothorax should be promptly diagnosed and treated by needle decompression closely followed with chest tube insertion (Grade D). All traumatic pneumothoraces are considered for chest tube insertion. However, observation is possible for selected patients with small unilateral pneumothoraces without respiratory disease or need for positive pressure ventilation (Grade C). Symptomatic traumatic haemothoraces or haemothoraces >500 ml should be treated by chest tube insertion (Grade D). Occult pneumothoraces and occult haemothoraces are managed by observation with daily chest X-rays (Grades B and C). Periprocedural antibiotics are used to prevent chest-tube-related infectious complications (Grade B). No sign of life at the initial assessment and cardiopulmonary resuscitation duration >10 min are considered as contraindications of Emergency Department Thoracotomy (Grade C). Damage Control Thoracotomy is performed for either massive air leakage or refractive shock or ongoing bleeding enhanced by chest tube output >1500 ml initially or >200 ml/h for 3 h (Grade D). In the case of haemodynamically stable patients, early video-assisted thoracic surgery is performed for retained haemothoraces (Grade B). Fixation of flail chest can be considered if mechanical ventilation for 48 h is probably required (Grade B). Fixation of sternal fractures is performed for displaced fractures with overlap or comminution, intractable pain or respiratory insufficiency (Grade D). Lung herniation, traumatic diaphragmatic rupture and pericardial rupture are life-threatening situations requiring prompt diagnosis and surgical advice. (Grades C and D). Tracheobronchial repair is mandatory in cases of tracheal tear >2 cm, oesophageal prolapse, mediastinitis or massive air leakage (Grade C). These evidence-based surgical indications for BCT management should support protocols for chest trauma management. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Waiting for Radiology Test Results: Patient Expectations and Emotional Disutility.
Woolen, Sean; Kazerooni, Ella A; Wall, Amber; Parent, Kelly; Cahalan, Shannon; Alameddine, Mitchell; Davenport, Matthew S
2018-02-01
To measure patient willingness to wait and emotional disutility of waiting for outpatient imaging test results. A prospective HIPAA-compliant multicenter outpatient quality improvement survey was administered by a trained interviewer to 218 outpatients from November 1, 2016, to February 1, 2017. The survey was vetted by patient- and family-centered care advocates with experience in survey design and underwent precognitive testing for readability. Six clinical scenarios were tested. Descriptive statistics were calculated. The response (93% [202 of 218]) and completion (93% [188 of 202]) rates were excellent. Anxiety (28% [57 of 202]), depression (26% [53 of 202]), and cancer (23% [46 of 202]) histories were common. Median stated expectations for imaging test results receipt were 3 days after a screening examination (interquartile range [IQR] 5 days); 2 days after chest x-ray for chest pain (IQR 3) or MRI or CT for back pain (IQR 2); and 1 day after chest x-ray for pneumonia (IQR 2), MRI or CT for brain tumor (IQR 2), or CT for cancer treatment (IQR 3). If imaging results are not received, the median time patients stated they would wait to call their provider was 1 to 5 days (varied by indication). Waiting for imaging results exerts an emotional change in 45% (91 of 202) of individuals, with the majority (85% [77 of 91]) experiencing anxiety (minimal 28%, mild 45%, moderate 22%, severe 4%, extreme 1%). Patients expect outpatient imaging results within 1 to 3 days and will call providers by 1 to 5 days. Waiting for test results commonly induces anxiety. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Bilateral Pneumothoraces in a Trauma Patient After Dobhoff Tube Insertion
Abidali, Ali; Mangram, Alicia; Shirah, Gina R.; Wilson, Whitney; Abidali, Ahmed; Moeser, Phillip; Dzandu, James K.
2018-01-01
Patient: Male, 74 Final Diagnosis: Pneumothorax Symptoms: Hypoxemia • shortness of breath Medication: — Clinical Procedure: — Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: Dobhoff tube insertion is a common procedure used in the clinical setting to deliver enteral nutrition. Although it is often viewed as an innocuous bedside procedure, there are risks for numerous complications such as tracheobronchial insertion, which could lead to deleterious consequences. We present to our knowledge the first reported case of bilateral pneumothoraces caused by the insertion of a Dobhoff tube. In addition, we also discuss common pitfalls for confirming the positioning of Dobhoff tubes, as well as risk factors that can predispose a patient to improper tube placement. Case Report: We present the case of a 74-year-old male patient with multiple orthopedic injuries following an auto-pedestrian collision. Five attempts were made to place a Dobhoff tube to maintain enteral nutrition. Follow-up abdominal x-ray revealed displacement of the Dobhoff tube in the left pleural space. After removal of the tube, a follow-up chest x-ray revealed iatrogenic bilateral pneumothoraces. Acute hypoxemic respiratory failure ensued; therefore, bilateral chest tubes were placed. Over the next three weeks, the patient’s respiratory status improved and both chest tubes were removed. The patient was eventually discharged to a skilled nursing facility. Conclusions: Improper placement of Dobhoff tubes can lead to rare complications such as bilateral pneumothoraces. This unique case report of bilateral pneumothoraces after Dobhoff tube placement emphasizes the necessity of using proper diagnostic techniques for verifying proper tube placement, as well as understanding the risk factors that predispose a patient to a malpositioned tube. PMID:29503437
Karmy-Jones, Riyad; Holevar, Michele; Sullivan, Ryan J; Fleisig, Ani; Jurkovich, Gregory J
2008-01-01
BACKGROUND: Empyema complicates tube thoracostomy following trauma in up to 10% of cases. Studies of potential risk factors of empyema have included use of antibiotics, site of injury and technique of chest tube placement. Residual fluid has also been cited as a risk factor for empyema, although the imaging technique to identify this varies. OBJECTIVE: To determine whether residual hemothorax detected by chest x-ray (CXR) after one or more initial chest tubes predicts an increased risk of empyema. METHODS: A study of patients admitted to two level I trauma centres between January 7, 2004, and December 31, 2004, was conducted. All patients who received a chest tube in the emergency department, did not undergo thoracotomy within 24 h, and survived more than two days were followed. Empyema was defined as a pleural effusion with positive cultures, and a ratio of pleural fluid lactate dehydrogenase to serum lactate dehydrogenase greater than 0.6 in the setting of elevated leukocyte count and fever. Factors analyzed included the presence of retained hemothorax on CXR after the most recent tube placement in the emergency room, age, mechanism of injury and injury severity score. RESULTS: A total of 102 patients met the criteria. Nine patients (9%) developed empyema: seven of 21 patients (33%) with residual hemothorax developed empyema versus two of 81 patients (2%) without residual hemothorax developed empyema (P=0.001). Injury severity score was significantly higher in those who developed empyema (31.4±26) versus those who did not (22.6±13; P=0.03). CONCLUSIONS: The presence of residual hemothorax detected by CXR after tube thoracostomy should prompt further efforts, including thoracoscopy, to drain it. With increasing injury severity, there may be increased benefit in terms of reducing empyema with this approach. PMID:18716687
Fracture of the wire stent in a Carpentier-Edwards porcine bioprosthesis.
Griffin, S; Bouboulis, N; Holden, M P
1993-05-01
A 60-year-old woman underwent mitral and aortic valve replacement with Carpentier-Edwards supra-annular bioprosthesis in 1986. Six years later rapidly progressing exercise dyspnea and orthopnea made hospital admission necessary. At chest x-ray and cardiac catheter examination one of the wire struts of the mitral bioprosthesis was found completely broken causing cusp prolapse. Surgical findings at reoperation confirmed the diagnosis. No apparent cause of the stent fracture was found.
The Acquisition of Perceptual Diagnostic Skill in Radiology.
1981-09-14
the x-ray. Finally, the right humeral (arm bone) lesions and the absent right breast support yet a third line of reasoning involving cancer and...that the patient did have metastatic involvement in the chest and had had a prior breast removal for breast cancer . Further, at least some of the three...dispositions for the film. Excluding the arm and absent breast , cancer was still concluded by fifteen (65%) subjects for at least one abnormality
Traumatic rupture of the thoracic aorta presenting as transient paraplegia.
Eaves, C C
1990-01-01
A patient involved in a high-speed motor vehicle accident presented paraplegic to the emergency department. He was noted to have an abnormal chest x-ray and, subsequently, underwent aortography which revealed aortic transection. The patient's paraplegia resolved spontaneously prior to definitive aortic repair hours later. Aortic rupture presenting as paraplegia is a rare association, but one an emergency physician should be cognizant of, especially in the case of blunt or decelerating trauma.
De, N V; Cong, L D; Kino, H; Son, D T; Vien, H V
2000-01-01
Sin Ho is a district of the northern mountainous province of Lai Chau, Vietnam, where the people have the habit of eating undercooked crabs. A study on paragoniamiasis carried out from 1994 to 1995 with 1,642 persons in this endemic area, showed that the rate of eating raw-crab was 72.5%. Crab examination (Ranguna kimboiensis) showed an infection rate of Paragonimus metacercaria of 98.1%. With 624 stool samples examined by Kato technique, the infection rate of Paragonimus in humans was 6.4%. With 338 sputum samples examined by direct and centrifuge methods, the infection rate of Paragonimus was 7.4%. Most of the patients were children (63.2%). The infection rate of Paragonimus in dogs was 18.2 - 33.3%. Adult worms, collected from the dogs in the field and from the cats in laboratory, were identified as Paragonimus heterotremus. The main symptoms of Paragonimus patients were cough and hemoptysis (92%), discontinuously developed (96%), without fever (94%), chest pain (70%), pleural effusion (26%), neurogical symptoms (8%), eosinophilia (88.9%), nodular ring shadows in the lungs, as shown by chest X-ray examination and more in lower lobe, (76.2%). Paragonimiasis patients were treated by (a) Praziquantel 25 mg/kg/day x 3 days; the cure rate was 68.8%. (b) Praziquantel 50 mg/kg/day x 3 days; the cure rate was 75%.
Smet, M H; Breysem, L; Mussen, E; Bosmans, H; Marshall, N W; Cockmartin, L
2018-07-01
To evaluate the impact of digital detector, dose level and post-processing on neonatal chest phantom X-ray image quality (IQ). A neonatal phantom was imaged using four different detectors: a CR powder phosphor (PIP), a CR needle phosphor (NIP) and two wireless CsI DR detectors (DXD and DRX). Five different dose levels were studied for each detector and two post-processing algorithms evaluated for each vendor. Three paediatric radiologists scored the images using European quality criteria plus additional questions on vascular lines, noise and disease simulation. Visual grading characteristics and ordinal regression statistics were used to evaluate the effect of detector type, post-processing and dose on VGA score (VGAS). No significant differences were found between the NIP, DXD and CRX detectors (p>0.05) whereas the PIP detector had significantly lower VGAS (p< 0.0001). Processing did not influence VGAS (p=0.819). Increasing dose resulted in significantly higher VGAS (p<0.0001). Visual grading analysis (VGA) identified a detector air kerma/image (DAK/image) of ~2.4 μGy as an ideal working point for NIP, DXD and DRX detectors. VGAS tracked IQ differences between detectors and dose levels but not image post-processing changes. VGA showed a DAK/image value above which perceived IQ did not improve, potentially useful for commissioning. • A VGA study detects IQ differences between detectors and dose levels. • The NIP detector matched the VGAS of the CsI DR detectors. • VGA data are useful in setting initial detector air kerma level. • Differences in NNPS were consistent with changes in VGAS.
[Characteristics of tuberculosis in the immigrant population in South Granada Health Area].
Morales-García, Concepción; Parra-Ruiz, Jorge; Valero-Aguilera, Beatriz; Sanbonmatsu-Gámez, Sara; Sánchez-Martínez, José Antonio; Hernández-Quero, José
2015-03-01
The incidence of tuberculosis (TB) among the native population in Spain continues to decrease, resulting in a higher proportion of foreign-born cases. The aim of this study was to identify the differential TB characteristics within the immigrant population with respect to the native population in the South Granada Health Area, Spain. This was a descriptive study, including all cases of TB diagnosed during the period 2003-2010. Cases were identified through a prospective database. A logistic regression analysis was performed to determine differential characteristics. From 319 TB cases diagnosed, 247 were natives and 72 (22.6%) immigrants, and 272 were pulmonary tuberculosis. The following variables were significantly associated with immigrant TB cases: age<35 years (OR=4.75, CI: 2.72-8.31), higher percentage of cavitated chest X-ray (OR=2.26, CI: 1.20-4.20), higher percentage of smear-positive cases (OR=1.80, CI: 1.02-3.16), longer diagnostic delay in smear-positive pulmonary TB (median 32 days vs. 21 days P=.043), and lower total lethality (OR=0.12; CI: 0.01-0.89). The incidence of TB has remained constant in the South Granada Health Area due to the increase in cases among immigrants. Compared with native TB patients, immigrant patients were younger and had more advanced disease (higher percentage of smear-positive cases and higher percentage of cavitated chest X-ray) and longer diagnostic delay in smear-positive pulmonary TB, indicating poorer TB control. Strategies for earlier diagnosis of TB in immigrants are essential. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
High prevalence of radiological vertebral fractures in HIV-infected males.
Torti, Carlo; Mazziotti, Gherardo; Soldini, Pier Antonio; Focà, Emanuele; Maroldi, Roberto; Gotti, Daria; Carosi, Giampiero; Giustina, Andrea
2012-06-01
Age-related co-morbidities including osteoporosis are relevant in patients responding to combination antiretroviral therapy (cART). Vertebral fractures are common osteoporotic fractures and their diagnosis is useful for managing at-risk individuals. However, there are few data from HIV-infected patients. Therefore, the aim of this study was to determine the prevalence of and factors associated with vertebral fractures in a population of HIV-infected males. A cross-sectional study of 160 HIV-infected patients with available chest X-rays was conducted from 1998 to 2010. One hundred and sixty-three males with comparable age and with no history of HIV infection were recruited as controls. Semi-quantitative evaluation of vertebral heights in lateral chest X-rays and quantitative morphometry assessment of centrally digitized images using dedicated morphometry software were utilized to detect prevalent vertebral fractures. The result showed that the vertebral fractures were detected in 43/160 (26.9%) HIV-infected patients and in 21/163 (12.9%) controls (P = 0.002). In HIV-infected patients with fractures, 27 had two or more fractures and ten patients had severe fractures. The prevalence of any fractures and multiple fractures in HIV-infected patients receiving cART (29.6 and 20.0%) was slightly higher than in HIV-infected patients not exposed to cART (17.1 and 5.7%), but significantly higher than control subjects (12.9 and 3.7%). At multivariable analyses, body mass index and diabetes mellitus were independently correlated with vertebral fractures in HIV-infected patients. We concluded that a significant proportion of HIV-infected males receiving cART showed vertebral fractures. Furthermore, proactive diagnosis of vertebral fragility fractures is particularly relevant in patients who are overweight or suffer from diabetes.
Hameed, Numan Nafie; Abdul Jaleel, Ra'id Khalil; Saugstad, Ola Didrik
2014-04-01
To study maternal and neonatal risk factors related to outcome of preterm babies with respiratory distress syndrome (RDS) on Continuous Positive Airway Pressure (CPAP) in a tertiary Iraqi NICU. A prospective case study carried out from January 5, 2011 to January 5, 2012, on 70 preterm neonates with RDS who were started on CPAP. Maternal and infant variables of preterm babies with successful or failed CPAP therapy were compared. Seventy neonates, 44 (63%) males and 26 (37%) females were included. Mean (SD) gestation was 32.8 (2.8) weeks and mean (SD) birth weight was 1860 (656) g. Thirty-seven (52.9%) babies failed CPAP, of them 29 (78.3%) were started on mechanical ventilation. The variables associated with failure of CPAP were: Birth weight ≤1500 g, gestational age ≤30 weeks, white out on the chest X-ray, FiO2 ≥50% at 20 min of CPAP, PEEP ≥5.5 cm H2O. Mortality rates were 94.6% in CPAP failures versus 5.4% in CPAP successes (p = 0.001). In infants surviving till discharge, duration of hospital stay was longer in babies who were CPAP successes (9.6 ± 3.7 versus 3.0 ± 2.7 days, p = 0.001). Gestational age, birth weight, whiteout chest X-ray, and FiO2 are important predictive values for success of CPAP therapy. A larger prospective multicenter controlled trial is needed to determine the benefits and risks of CPAP and predictors of its failure in our setting. Our results may be useful for others practicing in similar settings as us.
NASA Astrophysics Data System (ADS)
Alzubaidi, Mohammad; Patel, Ameet; Panchanathan, Sethuraman; Black, John A., Jr.
2010-02-01
Radiological images constitute a special class of images that are captured (or computed) specifically for the purpose of diagnosing patients. However, because these are not "natural" images, radiologists must be trained to interpret them through a process called "perceptual learning". However, because perceptual learning is implicit, experienced radiologists may sometimes find it difficult to explicitly (i.e. verbally) train less experienced colleagues. As a result, current methods of training can take years before a new radiologist is fully competent to independently interpret medical images. We hypothesize that eye tracking technology (coupled with multimedia technology) can be used to accelerate the process of perceptual training, through a Hebbian learning process. This would be accomplished by providing a radiologist-in-training with real-time feedback as he/she is fixating on important regions of an image. Of course this requires that the training system have information about what regions of an image are important - information that could presumably be solicited from experienced radiologists. However, our previous work has suggested that experienced radiologists are not always aware of those regions of an image that attract their attention, but are not clinically significant - information that is very important to a radiologist in training. This paper discusses a study in which local entropy computations were done on scan path data, and were found to provide a quantitative measure of the moment-by-moment interest level of radiologists as they scanned chest x-rays. The results also showed a striking contrast between the moment-by-moment deployment of attention between experienced radiologists and radiologists in training.
Lista, Gianluca; Bianchi, Silvia; Castoldi, Francesca; Fontana, Paola; Cavigioli, Francesco
2006-01-01
To evaluate the efficacy and safety of bronchoalveolar lavage (BAL) with diluted porcine surfactant in mechanically ventilated term infants with severe acute respiratory distress syndrome (ARDS) due to meconium aspiration syndrome (MAS). Eight consecutive mechanically ventilated term infants with severe ARDS due to MAS underwent BAL with 15 mL/kg of diluted (5.3mg phospholipid/mL) surfactant saline suspension (porcine surfactant [Curosurf]). Treatment was administered slowly in aliquots of 2.5 mL. The mean age of neonates at treatment was 3.5 (range 1-8) hours. Heart rate, systemic blood pressure and oxygen saturation were monitored continuously. Arterial blood gases were measured immediately before treatment, and again at 3 and 6 hours post-treatment. Chest x-rays were taken 6 and 24 hours after treatment. Radiological improvement was evident in all eight patients 6 hours post-treatment. Compared with pre-BAL values, significant improvements (p < 0.05) in mean values for partial pressure of oxygen in arterial blood, partial pressure of carbon dioxide in arterial blood, pH, arterial/alveolar O2 ratio and oxygenation index were documented at 3 and 6 hours after BAL. In all patients, tracheal fluids that had been meconium-stained prior to BAL were clear of meconium after BAL. Only one patient required nitric oxide therapy for transient pulmonary hypertension. No adverse sequelae of treatment occurred during the study. BAL with dilute porcine surfactant administered slowly in 2.5 mL aliquots improved oxygenation and chest x-ray findings, without causing major adverse effects, in mechanically ventilated term infants with ARDS due to MAS.
Lung function in the absence of respiratory symptoms in overweight children and adolescents*
de Assunção, Silvana Neves Ferraz; Daltro, Carla Hilário da Cunha; Boa Sorte, Ney Christian; Ribeiro, Hugo da Costa; Bastos, Maria de Lourdes; Queiroz, Cleriston Farias; Lemos, Antônio Carlos Moreira
2014-01-01
OBJECTIVE: To describe lung function findings in overweight children and adolescents without respiratory disease. METHODS: This was a cross-sectional study involving male and female overweight children and adolescents in the 8-18 year age bracket, without respiratory disease. All of the participants underwent anthropometric assessment, chest X-ray, pulse oximetry, spirometry, and lung volume measurements. Individuals with respiratory disease were excluded, as were those who were smokers, those with abnormal chest X-rays, and those with an SpO2 = 92%. Waist circumference was measured in centimeters. The body mass index-for-age Z score for boys and girls was used in order to classify the individuals as overweight, obese, or severely obese. Lung function variables were expressed in percentage of the predicted value and were correlated with the anthropometric indices. RESULTS: We included 59 individuals (30 males and 29 females). The mean age was 11.7 ± 2.7 years. Lung function was normal in 21 individuals (35.6%). Of the 38 remaining individuals, 19 (32.2%), 15 (25.4%), and 4 (6.7%) presented with obstructive, restrictive, and mixed ventilatory disorder, respectively. The bronchodilator response was positive in 15 individuals (25.4%), and TLC measurements revealed that all of the individuals with reduced VC had restrictive ventilatory disorder. There were significant negative correlations between the anthropometric indices and the Tiffeneau index in the individuals with mixed ventilatory disorder. CONCLUSIONS: Lung function was abnormal in approximately 65% of the individuals evaluated here, all of whom were overweight. Obstructive ventilatory disorder and positive bronchodilator response predominated. PMID:24831397
Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.
Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio
2011-08-02
Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.
Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W
2017-06-01
To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and reconstruction algorithms for reproducibility. Copyright © 2017 Elsevier B.V. All rights reserved.
A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists.
Farah, J; Struelens, L; Dabin, J; Koukorava, C; Donadille, L; Jacob, S; Schnelzer, M; Auvinen, A; Vanhavere, F; Clairand, I
2013-12-01
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, H(p)(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with H(p)(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, H(p)(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.
Sonography of iatrogenic pneumothorax in pediatric patients
2013-01-01
Pneumothorax is defined as the presence of air in the pleural cavity. The incidence of iatrogenic pneumothorax in the pediatric population is 0.3–0.48 in 1000 patients. A conventional chest X-ray, in some cases supplemented with chest computed tomography, is a typical imaging examination used to confirm the diagnosis of pneumothorax. Within the last years, the relevance of transthoracic lung ultrasound in the diagnostic process of this disease entity has greatly increased. This is confirmed by the opinion of a group of experts in ultrasound lung imaging in patients in a life-threatening condition, who strongly recommend a transthoracic ultrasound examination for the diagnosis of pneumothorax in such patients. These data constituted the basis for initiating the prospective studies on the application of this method in pneumothorax diagnosis in patients of pediatric hematology and oncology wards. Aim The aim of the study was to present the possibility of using the transthoracic lung ultrasound in the diagnostic process of pneumothorax in pediatric patients, with particular attention paid to its iatrogenic form. The article discusses sonographic criteria for pneumothorax diagnosis in pediatric patients, including the sensitivity and specificity of the method, in relation to conventional chest X-ray. Material and methods The prospective studies included a group of patients treated in the Clinic of Pediatrics, Pediatric Hematology, Oncology and Endocrinology of the Academic Clinical Centre (Medical University of Gdańsk, Poland) in whom a central venous catheter was placed in the subclavian veins. The studies lasted for one year – from 1 July 2011 to 30 June 2012. The examined group comprised 63 patients – 25 girls (39.7%) and 38 boys (60.3%) aged from 1 to 17. The analysis included the results of 115 ultrasound examinations conducted in this group. Results In t he examined group with suspected or diagnosed neoplasm, iatrogenic pneumothorax was identified in 4 out of 63 patients (6.3%). In all cases, it was a consequence of procedures connected with the introduction of a central catheter. In the examined material, the sensitivity, specificity and predictive values (positive and negative) of the transthoracic lung ultrasound equaled 100%. Conclusions The transthoracic ultrasound examination is a highly effective method in diagnosing iatrogenic pneumothorax in pediatric patients. However, to confirm this conclusion, multicenter studies, among considerably larger populations, are necessary. PMID:26675373
Asymptomatic Presentation of Large Cardiac Hydatid.
Beedkar, Amey; Parikh, Rohan; Deshmukh, Pradeep
2017-02-01
Hydatid cyst is a tissue parasitic infection caused by tapeworm Echinococcus granulosus. Common location for hydatid cysts are the liver (65%) and the lungs (25%). Cardiac hydatid cyst is seen rarely, occurring in about 0.5-2% of all cases of hydatid disease. We present this case of 45 years female who presented with short duration of dry cough and atypical chest pain. Chest X ray showed cardiomegaly with round bulge at the right heart border and curvilinear calcification in left upper abdomen in the region of spleen. Transthoracic echocardiography (TTE) depicted cystic lesion in Right Ventricle free wall causing compression of right atrial and ventricular cavity. Cardiac CT confirmed this cyst as hydatid cyst. Patient underwent successful excision of right ventricular hydatid cyst. © Journal of the Association of Physicians of India 2011.
Kilimcioğlu, Ali A; Ozkol, Mine; Bayindir, Petek; Girginkardeşler, Nogay; Ostan, Ipek; Ok, Ulgen Z
2006-12-01
A total of 1,205 primary school children were examined for cystic echinococcosis in five villages of Manisa, Turkey, to evaluate the efficacy of diagnostic methods of this infection in community-based screening surveys. Six hundred and thirty children from three villages, examined by a portable ultrasound scanner, chest microfilm and serological methods (ELISA, indirect hemagglutination) in our previous study, were designated as Study Group 1; and 575 children, from two adjacent villages, examined by ultrasonography alone in the present study, were designated as Study Group 2. In Study Group 1, hepatic cystic echinococcosis was detected in two cases (0.3%) by ultrasonography, while 43 (8.9%) and 49 (10.1%) cases were found to be positive for cystic echinococcosis by ELISA and indirect hemagglutination, respectively. Three of 575 children (0.5%) were diagnosed with cystic echinococcosis (two hepatic and one renal involvement) by ultrasonography alone in Study Group 2; and lung lesions were later detected in both cases with liver involvement by chest radiography. Our results suggested that serological tests may be beneficial in suspected cases for confirmation and differential diagnosis, but have some drawbacks, such as discrepancy in results and high false seropositivity rates. Chest microfilm is not easy in field studies and exposure to X-ray is undesirable. As a reliable, simple, inexpensive and rapid technique, ultrasonography alone is recommended to be used in community-based screening surveys for cystic echinococcosis with confirmatory tests for suspected cases found during the screening program.