Liu, Zhenxing; Reddy, Govardhan; O’Brien, Edward P.; Thirumalai, D.
2011-01-01
Quantitative description of how proteins fold under experimental conditions remains a challenging problem. Experiments often use urea and guanidinium chloride to study folding whereas the natural variable in simulations is temperature. To bridge the gap, we use the molecular transfer model that combines measured denaturant-dependent transfer free energies for the peptide group and amino acid residues, and a coarse-grained Cα-side chain model for polypeptide chains to simulate the folding of src SH3 domain. Stability of the native state decreases linearly as [C] (the concentration of guanidinium chloride) increases with the slope, m, that is in excellent agreement with experiments. Remarkably, the calculated folding rate at [C] = 0 is only 16-fold larger than the measured value. Most importantly ln kobs (kobs is the sum of folding and unfolding rates) as a function of [C] has the characteristic V (chevron) shape. In every folding trajectory, the times for reaching the native state, interactions stabilizing all the substructures, and global collapse coincide. The value of (mf is the slope of the folding arm of the chevron plot) is identical to the fraction of buried solvent accessible surface area in the structures of the transition state ensemble. In the dominant transition state, which does not vary significantly at low [C], the core of the protein and certain loops are structured. Besides solving the long-standing problem of computing the chevron plot, our work lays the foundation for incorporating denaturant effects in a physically transparent manner either in all-atom or coarse-grained simulations. PMID:21512127
Liu, Zhenxing; Reddy, Govardhan; O'Brien, Edward P; Thirumalai, D
2011-05-10
Quantitative description of how proteins fold under experimental conditions remains a challenging problem. Experiments often use urea and guanidinium chloride to study folding whereas the natural variable in simulations is temperature. To bridge the gap, we use the molecular transfer model that combines measured denaturant-dependent transfer free energies for the peptide group and amino acid residues, and a coarse-grained C(α)-side chain model for polypeptide chains to simulate the folding of src SH(3) domain. Stability of the native state decreases linearly as [C] (the concentration of guanidinium chloride) increases with the slope, m, that is in excellent agreement with experiments. Remarkably, the calculated folding rate at [C] = 0 is only 16-fold larger than the measured value. Most importantly ln k(obs) (k(obs) is the sum of folding and unfolding rates) as a function of [C] has the characteristic V (chevron) shape. In every folding trajectory, the times for reaching the native state, interactions stabilizing all the substructures, and global collapse coincide. The value of (m(f) is the slope of the folding arm of the chevron plot) is identical to the fraction of buried solvent accessible surface area in the structures of the transition state ensemble. In the dominant transition state, which does not vary significantly at low [C], the core of the protein and certain loops are structured. Besides solving the long-standing problem of computing the chevron plot, our work lays the foundation for incorporating denaturant effects in a physically transparent manner either in all-atom or coarse-grained simulations.
Chen, Tao; Chan, Hue Sun
2014-04-14
Local-nonlocal coupling is an organizational principle in protein folding. It envisions a cooperative energetic interplay between local conformational preferences and favorable nonlocal contacts. Previous theoretical studies by our group showed that two classes of native-centric coarse-grained models can capture the experimentally observed high degrees of protein folding cooperativity and diversity in folding rates. These models either embody an explicit local-nonlocal coupling mechanism or incorporate desolvation barriers in the models' pairwise interactions. Here a conceptual connection is made between these two paradigmatic coarse-grained interaction schemes by showing that desolvation barriers enhance local-nonlocal coupling. Furthermore, we find that a class of coarse-grained protein models with a single-site representation of sidechains also increases local-nonlocal coupling relative to mainchain models without sidechains. Enhanced local-nonlocal coupling generally leads to higher folding cooperativity and chevron plots with more linear folding arms. For the sidechain models studied, the chevron plot simulated with entirely native-centric intrachain interactions behaves very similarly to the corresponding chevron plots simulated with interactions that are partly modulated by sequence- and denaturant-dependent transfer free energies. In these essentially native-centric models, the mild chevron rollovers in the simulated folding arm are caused by occasionally populated intermediates as well as the movement of the unfolded and putative folding transition states. The strength and limitation of the models are analyzed by comparison with experiment. New formulations of sidechain models that may provide a physical account for nonnative interactions are also explored.
Folding domain B of protein A on a dynamically partitioned free energy landscape.
Nelson, Erik D; Grishin, Nick V
2008-02-05
The B domain of staphylococcal protein A (BdpA) is a small helical protein that has been studied intensively in kinetics experiments and detailed computer simulations that include explicit water. The simulations indicate that BdpA needs to reorganize in crossing the transition barrier to facilitate folding its C-terminal helix (H3) onto the nucleus formed from helices H1 and H2. This process suggests frustration between two partially ordered forms of the protein, but recent varphi value measurements indicate that the transition structure is relatively constant over a broad range of temperatures. Here we develop a simplistic model to investigate the folding transition in which properties of the free energy landscape can be quantitatively compared with experimental data. The model is a continuation of the Muñoz-Eaton model to include the intermittency of contacts between structured parts of the protein, and the results compare variations in the landscape with denaturant and temperature to varphi value measurements and chevron plots of the kinetic rates. The topography of the model landscape (in particular, the feature of frustration) is consistent with detailed simulations even though variations in the varphi values are close to measured values. The transition barrier is smaller than indicated by the chevron data, but it agrees in order of magnitude with a similar alpha-carbon type of model. Discrepancies with the chevron plots are investigated from the point of view of solvent effects, and an approach is suggested to account for solvent participation in the model.
Optical Fourier filtering for whole lens assessment of progressive power lenses.
Spiers, T; Hull, C C
2000-07-01
Four binary filter designs for use in an optical Fourier filtering set-up were evaluated when taking quantitative measurements and when qualitatively mapping the power variation of progressive power lenses (PPLs). The binary filters tested were concentric ring, linear grating, grid and "chevron" designs. The chevron filter was considered best for quantitative measurements since it permitted a vernier acuity task to be used for measuring the fringe spacing, significantly reducing errors, and it also gave information on the polarity of the lens power. The linear grating filter was considered best for qualitatively evaluating the power variation. Optical Fourier filtering and a Nidek automatic focimeter were then used to measure the powers in the distance and near portions of five PPLs of differing design. Mean measurement error was 0.04 D with a maximum value of 0.13 D. Good qualitative agreement was found between the iso-cylinder plots provided by the manufacturer and the Fourier filter fringe patterns for the PPLs indicating that optical Fourier filtering provides the ability to map the power distribution across the entire lens aperture without the need for multiple point measurements. Arguments are presented that demonstrate that it should be possible to derive both iso-sphere and iso-cylinder plots from the binary filter patterns.
Malmblorg, William T.; West, William B.; Brabb, Earl E.; Parker, John M.
2008-01-01
The general location and age of more than 33,500 mostly foraminifer samples from Chevron surface localities in nearly 600 U.S. Geological Survey (USGS) 7.5' quadrangles from California were provided by Brabb and Parker (2003). Barren and non-diagnostic samples plus many that have no paleontologic information were omitted to provide a revised list for more than 27,000 of these samples by Brabb and Parker (2005). The locations for many of these samples were recorded by Chevron geoscientists on topographic maps (originals now in the USGS Library in Menlo Park, Calif.). The recent availability of digital databases for geologic and topographic maps has provided the opportunity to prepare a database of the locations of these Chevron samples so that the information can be combined with geology and topography for plotting or geospatial analysis. This report provides specific locations for more than 13,000 samples in central California that have enough paleontologic information to determine their age but omits thousands of samples that are too closely spaced to differentiate or those that have only a general location.
Numerical investigation of mixing characterstics of chevron nozzle by passive controls method
NASA Astrophysics Data System (ADS)
Devipriya, J.; Kanimozhi, Dr.
2017-05-01
This paper deals with the Reduction of noise in the aircraft exhaust is done by installing Chevrons with particular parameters in the Nozzle section. Numerical investigations have been carried out on chevron Nozzles to evaluate the importance of Chevron parameters by adding number of Chevrons and the mixing characteristics of jet. After assessing the Chevron parameters we vary the Chevron shapes at the exit by installing the triangular wedge in order to regulate maximum noise reduction along with a negligible thrust loss. Finally the results is compared with free jet Nozzle with Chevron and Chevron with wedge has been analysed using CFX CFD software and the results of potential core decay of these Nozzles has been measured from the analysis.
Discrete kinetic models from funneled energy landscape simulations.
Schafer, Nicholas P; Hoffman, Ryan M B; Burger, Anat; Craig, Patricio O; Komives, Elizabeth A; Wolynes, Peter G
2012-01-01
A general method for facilitating the interpretation of computer simulations of protein folding with minimally frustrated energy landscapes is detailed and applied to a designed ankyrin repeat protein (4ANK). In the method, groups of residues are assigned to foldons and these foldons are used to map the conformational space of the protein onto a set of discrete macrobasins. The free energies of the individual macrobasins are then calculated, informing practical kinetic analysis. Two simple assumptions about the universality of the rate for downhill transitions between macrobasins and the natural local connectivity between macrobasins lead to a scheme for predicting overall folding and unfolding rates, generating chevron plots under varying thermodynamic conditions, and inferring dominant kinetic folding pathways. To illustrate the approach, free energies of macrobasins were calculated from biased simulations of a non-additive structure-based model using two structurally motivated foldon definitions at the full and half ankyrin repeat resolutions. The calculated chevrons have features consistent with those measured in stopped flow chemical denaturation experiments. The dominant inferred folding pathway has an "inside-out", nucleation-propagation like character.
NASA Technical Reports Server (NTRS)
Shannon, J. L., Jr.; Munz, D. G.
1983-01-01
Plane strain fracture toughness measurements were made on Al2O3 using short rod and short bar chevron notch specimens previously calibrated by the authors for their dimensionless stress intensity factor coefficients. The measured toughness varied systematically with variations in specimen size, proportions, and chevron notch angle apparently due to their influence on the amount of crack extension to maximum load (the measurement point). The toughness variations are explained in terms of a suspected rising R curve for the material tested, along with a discussion of an unavoidable imprecision in the calculation of K sub Ic for materials with rising R curves when tested with chevron notch specimens.
Acoustic Efficiency of Azimuthal Modes in Jet Noise Using Chevron Nozzles
NASA Technical Reports Server (NTRS)
Brown, Clifford A.; Bridges, James
2006-01-01
The link between azimuthal modes in jet turbulence and in the acoustic sound field has been examined in cold, round jets. Chevron nozzles, however, impart an azimuthal structure on the jet with a shape dependent on the number, length and penetration angle of the chevrons. Two particular chevron nozzles, with 3 and 4 primary chevrons respectively, and a round baseline nozzle are compared at both cold and hot jet conditions to determine how chevrons impact the modal structure of the flow and how that change relates to the sound field. The results show that, although the chevrons have a large impact on the azimuthal shape of the mean axial velocity, the impact of chevrons on the azimuthal structure of the fluctuating axial velocity is small at the cold jet condition and smaller still at the hot jet condition. This is supported by results in the azimuthal structure of the sound field, which also shows little difference in between the two chevron nozzles and the baseline nozzle in the distribution of energy across the azimuthal modes measured.
Deenik, Axel; van Mameren, Henk; de Visser, Enrico; de Waal Malefijt, Maarten; Draijer, Frits; de Bie, Rob
2008-12-01
Chevron osteotomy is a widely accepted osteotomy for correction of hallux valgus.(18) Algorithms were developed to overcome the limitations of distal osteotomies. Scarf osteotomy has become popular as a versatile procedure that should be able to correct most cases of acquired hallux valgus. The purpose of this study was to evaluate whether patients with moderate or severe hallux valgus have better correction with a scarf osteotomy as compared to chevron osteotomy. After informed consent, 136 feet in 115 patients were randomized to 66 scarf and 70 chevron osteotomies. Deformities of patients were classified as mild, moderate and severe according to IMA, and both groups were compared with independent t-tests. The results were measured using radiographic HVA, IMA and DMAA measurements. There were no statistical differences in HVA, IMA and DMAA between scarf and chevron osteotomy in mild to moderate hallux valgus. In severe hallux valgus, chevron osteotomy corrected HVA better than scarf osteotomy, although this group consisted of twelve patients only. Five patients in the chevron group and seven in the scarf group developed recurrent subluxation of the metatarsophalangeal joint. In patients with moderate and severe hallux valgus, the results of chevron osteotomy were at least as effective as a scarf osteotomy. Recurrent subluxation of the first metatatarsophalangeal joint was the main cause for insufficient correction. We favor the chevron osteotomy because it is less invasive, without sacrificing correction of HVA and IMA.
Design, Fabrication, and Testing of SMA Enabled Adaptive Chevrons for Jet Noise Reduction
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Buehrle, Ralph D.; Cano, Roberto J.; Fleming, Gary A.
2004-01-01
This study presents the status and results from an effort to design, fabricate, and test an adaptive jet engine chevron concept based upon embedding shape memory alloy (SMA) actuators in a composite laminate, termed a SMA hybrid composite (SMAHC). The approach for fabricating the adaptive SMAHC chevrons involves embedding prestrained Nitinol actuators on one side of the mid-plane of the composite laminate such that thermal excitation generates a thermal moment and deflects the structure. A glass-epoxy pre-preg/Nitinol ribbon material system and a vacuum hot press consolidation approach are employed. A versatile test system for control and measurement of the chevron deflection performance is described. Projection moire interferometry (PMI) is used for global deformation measurement and infrared (IR) thermography is used for 2-D temperature measurement and feedback control. A recently commercialized constitutive model for SMA and SMAHC materials is used in the finite element code ABAQUS to perform nonlinear static analysis of the chevron prototypes. Excellent agreement is achieved between the predicted and measured chevron deflection performance, thereby validating the design tool. Although the performance results presented in this paper fall short of the requirement, the concept is proven and an approach for achieving the performance objectives is evident.
Fractured toughness of Si3N4 measured with short bar chevron-notched specimens
NASA Technical Reports Server (NTRS)
Salem, J. A.; Shannon, J. L., Jr.
1985-01-01
The short bar chevron-notched specimen is used to measure the plane strain fracture toughness of hot pressed Si3N4. Specimen proportions and chevron-notch angle are varied, thereby varying the amount of crack extension to maximum load (upon which K sub IC is based). The measured toughness (4.68 + or - 0.19 MNm to the 3/2 power) is independent of these variations, inferring that the material has a flat crack growth resistance curve.
Fracture toughness of Si3N4 measured with short bar chevron-notched specimens
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Shannon, John L., Jr.
1987-01-01
The short bar chevron-notched specimen is used to measure the plane strain fracture toughness of hot pressed Si3N4. Specimen proportions and chevron-notch angle are varied, thereby varying the amount of crack extension to maximum load (upon which K sub IC is based). The measured toughness (4.68 + or 0.19 MNm to the 3/2 power) is independent of these variations, inferring that the material has a flat crack growth resistance curve.
Effect of chevron nozzle penetration on aero-acoustic characteristics of jet at M = 0.8
NASA Astrophysics Data System (ADS)
Nikam, S. R.; Sharma, S. D.
2017-12-01
Aero-acoustic characteristics of a high-speed jet with chevron nozzles are experimentally investigated at a Mach number of 0.8. The main focus is to examine the effects of the extent of chevron penetration and its position in the mixing layer. Chevron nozzles with three different levels of penetration employed at three different longitudinal locations from the nozzle lip are tested, and the results are compared with those of a plain baseline nozzle. The chevrons are found to produce a lobed shear layer through the notched region, thereby increasing the surface area of the jet, particularly in the close vicinity of the nozzle, which increases the mixing and reduces the potential core length. This effect becomes more prominent with increasing penetration closer to the nozzle lip in the thinner mixing layer. Near field and far field noise measurements show distinctly different acoustic features due to chevrons. The chevrons are found to effectively shift the dominant noise source upstream closer to the nozzle. Present investigation proposes a simpler method for locating the dominant noise source from the peak of the centerline velocity decay rate. The overall noise levels registered along the jet edge immediately downstream of the chevrons are higher, but further downstream they are reduced in comparison with the plain baseline nozzle. Also, the chevrons beam the noise towards higher polar angles at higher frequencies. At shallow polar angles with respect to the jet axis in the far field, chevrons suppress the noise at low frequencies with increasing penetration, but for higher polar angles, while they continue to suppress the low frequency noise, at higher frequencies the trend is found to reverse. The noise measured in the near field close to the jet edge is composed of two components: acoustic and hydrodynamic. Of these two components, the chevrons are found to reduce the hydrodynamic component in comparison with the acoustic one.
Compliance measurements of chevron notched four point bend specimen
NASA Technical Reports Server (NTRS)
Calomino, Anthony; Bubsey, Raymond; Ghosn, Louis J.
1994-01-01
The experimental stress intensity factors for various chevron notched four point bend specimens are presented. The experimental compliance is verified using the analytical solution for a straight through crack four point bend specimen and the boundary integral equation method for one chevron geometry. Excellent agreement is obtained between the experimental and analytical results. In this report, stress intensity factors, loading displacements and crack mouth opening displacements are reported for different crack lengths and different chevron geometries, under four point bend loading condition.
Scarf versus chevron osteotomy in hallux valgus: a randomized controlled trial in 96 patients.
Deenik, A R; Pilot, P; Brandt, S E; van Mameren, H; Geesink, R G T; Draijer, W F
2007-05-01
The degree of correction of hallux valgus deformity using a distal chevron osteotomy is reported as limited. The scarf osteotomy is reported to correct large intermetatarsal angles (IMA). The purpose of this study was to evaluate if one technique gave greater correction of the IMA and hallux valgus angle (HVA) than the other. After informed consent, 96 feet in 83 patients were randomized into two treatment groups (49 scarf and 47 chevron osteotomies). The results were evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) Hallux Valgus Scale and radiographic HVA and IMA measurements. At 27 (range 23-31) months followup both groups improved. The AOFAS score in the chevron group improved from 48 to 89 points and in the scarf group from 47 to 91 points. In the chevron group the HVA corrected from 30 to 17 degrees, and in the scarf group the HVA corrected from 29 to 18 degrees. In both groups, the IMA was corrected from 13 to 10 degrees. The differences were not statistically significant. Three patients in the chevron group developed a partial metatarsal head necrosis. In the scarf group, four patients developed grade 1 complex regional pain syndrome compared to one patient in the chevron group. No differences of statistical significance could be measured between the two groups with respect to the AOFAS score, HVA, and IMA. Although both groups showed good to excellent results, we favor the chevron osteotomy because the procedure is technically less demanding.
PIV Measurements of Chevrons on F400 Tactical Aircraft Nozzle Model
NASA Technical Reports Server (NTRS)
Bridges, James; Wernet, Mark; Frate, Franco
2010-01-01
Previous talks at this meeting have covered our collaborative work on high-energy jets such as present in tactical aircraft (those with supersonic plumes). The emphasis of this work is improving our understanding of flow physics and our prediction tools. In this presentation we will discuss recent flow diagnostics acquired using Particle Image Velocimetry (PIV) made on an underexpanded shocked jet plume from a tactical aircraft nozzle. In this presentation we show cross-sectional and streamwise cuts of both mean and turbulent velocities of an F404 engine nozzle with various chevron designs applied. The impact of chevron penetration, length, and width are documented. The impact of the parameters is generally nonlinear in measures considered here, a surprising result given the relatively smooth behavior of the noise to variations in these chevron parameters.
NASA Technical Reports Server (NTRS)
Bubsey, R. T.; Pierce, W. S.; Shannon, J. L., Jr.; Munz, D.
1982-01-01
The short rod chevron-notch specimen has the advantages of (1) crack development at the chevron tip during the early stage of test loading, and (2) convenient calculation of plane-strain fracture toughness from the maximum test load and from a calibration factor which depends only on the specimen geometry and manner of loading. For generalized application, calibration of the specimen over a range of specimen proportions and chevron-notch configurations is necessary. Such was the objective of this investigation, wherein calibration of the short rod specimen was made by means of experimental compliance measurements converted into dimensionless stress intensity factor coefficients.
NASA Astrophysics Data System (ADS)
Brasser, C.; Bruckbauer, J.; Gong, Y.; Jiu, L.; Bai, J.; Warzecha, M.; Edwards, P. R.; Wang, T.; Martin, R. W.
2018-05-01
Epitaxial overgrowth of semi-polar III-nitride layers and devices often leads to arrowhead-shaped surface features, referred to as chevrons. We report on a study into the optical, structural, and electrical properties of these features occurring in two very different semi-polar structures, a blue-emitting multiple quantum well structure, and an amber-emitting light-emitting diode. Cathodoluminescence (CL) hyperspectral imaging has highlighted shifts in their emission energy, occurring in the region of the chevron. These variations are due to different semi-polar planes introduced in the chevron arms resulting in a lack of uniformity in the InN incorporation across samples, and the disruption of the structure which could cause a narrowing of the quantum wells (QWs) in this region. Atomic force microscopy has revealed that chevrons can penetrate over 150 nm into the sample and quench light emission from the active layers. The dominance of non-radiative recombination in the chevron region was exposed by simultaneous measurement of CL and the electron beam-induced current. Overall, these results provide an overview of the nature and impact of chevrons on the luminescence of semi-polar devices.
Cooper, Minton Truitt; Coughlin, Michael J
2012-10-01
The aim of this study was to compare a distal subcapital oblique fifth metatarsal with a distal chevron osteotomy for correction of bunionette deformity. Twenty cadaveric feet were randomly assigned to undergo either a subcapital oblique or chevron osteotomy of the distal fifth metatarsal. Radiographic measurements, including 4-5 intermetatarsal angle (IMA), fifth metatarsophalangeal angle (5-MPA) and foot width, were compared between the 2 groups. Foot width and 5-MPA was significantly decreased in both groups with no difference between the groups. The 4-5 IMA was not significantly altered in either group. Decrease in foot width and 5-MPA was similarly achieved with either distal chevron or subcapital oblique osteotomy of the fifth metatarsal in normal cadaveric specimens. No significant difference was found between the 2 techniques in any of the radiographic parameters measured.
Bulk properties of solution-synthesized chevron-like graphene nanoribbons.
Vo, Timothy H; Shekhirev, Mikhail; Lipatov, Alexey; Korlacki, Rafal A; Sinitskii, Alexander
2014-01-01
Graphene nanoribbons (GNRs) have received a great deal of attention due to their promise for electronic and optoelectronic applications. Several recent studies have focused on the synthesis of GNRs by the bottom-up approaches that could yield very narrow GNRs with atomically precise edges. One type of GNRs that has received a considerable attention is the chevron-like GNR with a very distinct periodic structure. Surface-assisted and solution-based synthetic approaches for the chevron-like GNRs have been developed, but their electronic properties have not been reported yet. In this work, we synthesized chevron-like GNRs in bulk by a solution-based method, characterized them by a number of spectroscopic techniques and measured their bulk conductivity. We demonstrate that solution-synthesized chevron-like GNRs are electrically conductive in bulk, which makes them a potentially promising material for applications in organic electronics and photovoltaics.
Mahadevan, Devendra; Lines, Stephen; Hepple, Stephen; Winson, Ian; Harries, William
2016-06-01
The purpose of this RCT was to compare the extended plantar limb (modified) chevron osteotomy with the scarf osteotomy in correcting hallux valgus deformity and improving functional scores and patient satisfaction. Patients were randomly assigned and kept blind to surgical allocation. Cases requiring additional procedures including the Akin osteotomy were excluded. Outcomes were measured at 1 year following surgery. 84 patients (109 feet) were analysed (60 modified chevron; 49 Scarf). The mean age was 50.7 years (75F: 9M). Post-operative intermetatarsal angle (IMA) was significantly lower in the modified chevron group (5.8° versus 6.9°, p=0.045). Hallux valgus angle and distal metatarsal articular angle were similar. The magnitude of IMA correction with the modified chevron was also significantly greater (9.1° versus 7.1°, p=0.007). Both osteotomies produced comparable MOxFQ scores and satisfaction ratings. The modified chevron was superior to the scarf osteotomy in correcting IMA in hallux valgus deformity. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wright, C.A.; Weijers, L.; Minner, W.A.
1996-07-01
This report describes the results from Chevron`s Pakenham Field effort at fracture stimulation engineering which incorporated, to the greatest extent possible, the results of actual measured field data. Measurement of the sand-shale closure stress contrast around the Wolfcamp A2 sand and the relatively high net fracturing pressures (compared to the closure stress contrast) that were observed during real-data (net pressure) fracture treatment analysis revealed that fractures obtained in most of the treatments were much shorter and less confined than originally expected: the fracture half-length was about 200 to 300 ft (instead of about 600 ft), which is consistent with estimatesmore » from post-fracture pressure build-up tests. Based on these measurements, Chevron`s fracturing practices in the Pakenham Field could be carefully reviewed to enhance fracture economics. Supported by the real-data fracture treatment analysis, several changes in completion, fracture treatment design and data-collection procedures were made, such as: (1) using cheaper 20/40 Ottawa sand instead of pre-cured 20/40 resin coated sand; (2) reducing the pad fluid size, as fluid leakoff from the fracture into the formation was relatively low; and, (3) utilizing stepdown tests and proppant slugs to minimize near-wellbore screen-out potential (in the Wolfcamp D sand).« less
Parametric Testing of Chevrons on Single Flow Hot Jets
NASA Technical Reports Server (NTRS)
Bridges, James; Brown, Clifford A.
2004-01-01
A parametric family of chevron nozzles have been studied, looking for relationships between chevron geometric parameters, flow characteristics, and far-field noise. Both cold and hot conditions have been run at acoustic Mach number 0.9. Ten models have been tested, varying chevron count, penetration, length, and chevron symmetry. Four comparative studies were defined from these datasets which show: that chevron length is not a major impact on either flow or sound; that chevron penetration increases noise at high frequency and lowers it at low frequency, especially for low chevron counts; that chevron count is a strong player with good low frequency reductions being achieved with high chevron count without strong high frequency penalty; and that chevron asymmetry slightly reduces the impact of the chevron. Finally, it is shown that although the hot jets differ systematically from the cold one, the overall trends with chevron parameters is the same.
[Distal osteotomy for the treatment of hallux valgus (Chevron osteotomy)].
Stukenborg-Colsman, C; Claaßen, L; Ettinger, S; Yao, D; Lerch, M; Plaaß, C
2017-05-01
Distal osteotomies, like the Chevron osteotomy, is indicated for mild to moderate hallux valgus deformities. Splayfoot, painful pseudoexostosis, and transfer metatasalgia are observed in the clinical examination. Radiographic examination should be done with weight bearing in two planes. Preoperatively the intermetatarsal (IM), hallux valgus, and distal metatarsal articular (DMAA) angles should be measured. The operative technique is based on soft tissue and bony correction. Modifications of the osteotomy allow a shortening, lengthening, or neutral correction of the first metatarsal. With a modified Chevron osteotomy, an increased DMAA can be also corrected.
Feedback Control of a Morphing Chevron for Takeoff and Cruise Noise Reduction
NASA Technical Reports Server (NTRS)
Cabell, Randolph H.; Schiller, Noah H.; Mabe, James H.; Ruggeri, Robert T.; Butler, G. W.
2004-01-01
Noise from commercial high-bypass ratio turbofan engines is generated by turbulent mixing of the hot jet exhaust, fan stream, and ambient air. Serrated aerodynamic devices, known as chevrons, along the trailing edges of a jet engine primary and secondary exhaust nozzle have been shown to reduce jet noise at takeoff and shock-cell noise at cruise conditions. Their optimum shape is a finely tuned compromise between noise-benefit and thrust-loss. The design of a full scale Variable Geometry Chevron (VGC) fan-nozzle incorporating Shape Memory Alloy (SMA) actuators is described in a companion paper. This paper describes the development and testing of a proportional-integral control system that regulates the heating of the SMA actuators to control the VGC s tip immersion. The VGC and control system were tested under representative flow conditions in Boeing s Nozzle Test Facility (NTF). Results from the NTF test which demonstrate controllable immersion of the VGC are described. The paper also describes the correlation between strains and temperatures on the chevron with a photogrammetric measurement of the chevron's tip immersion.
Mean Flow and Noise Prediction for a Separate Flow Jet With Chevron Mixers
NASA Technical Reports Server (NTRS)
Koch, L. Danielle; Bridges, James; Khavaran, Abbas
2004-01-01
Experimental and numerical results are presented here for a separate flow nozzle employing chevrons arranged in an alternating pattern on the core nozzle. Comparisons of these results demonstrate that the combination of the WIND/MGBK suite of codes can predict the noise reduction trends measured between separate flow jets with and without chevrons on the core nozzle. Mean flow predictions were validated against Particle Image Velocimetry (PIV), pressure, and temperature data, and noise predictions were validated against acoustic measurements recorded in the NASA Glenn Aeroacoustic Propulsion Lab. Comparisons are also made to results from the CRAFT code. The work presented here is part of an on-going assessment of the WIND/MGBK suite for use in designing the next generation of quiet nozzles for turbofan engines.
NASA Technical Reports Server (NTRS)
Munz, D.; Bubsey, R. T.; Shannon, J. L., Jr.
1980-01-01
Ease of preparation and testing are advantages unique to the chevron-notch specimen used for the determination of the plane strain fracture toughness of extremely brittle materials. During testing, a crack develops at the notch tip and extends stably as the load is increased. For a given specimen and notch configuration, maximum load always occurs at the same relative crack length independent of the material. Fracture toughness is determined from the maximum load with no need for crack length measurement. Chevron notch acuity is relatively unimportant since a crack is produced during specimen loading. In this paper, the authors use their previously determined stress intensity factor relationship for the chevron-notch short bar specimen to examine the performance of that specimen in determining the plane strain fracture toughness of silicon nitride and aluminum oxide.
NASA Astrophysics Data System (ADS)
Wei, Ming-Dong; Dai, Feng; Xu, Nu-Wen; Liu, Jian-Feng; Xu, Yuan
2016-05-01
The cracked chevron notched semi-circular bending (CCNSCB) method for measuring the mode I fracture toughness of rocks combines the merits (e.g., avoidance of tedious pre-cracking of notch tips, ease of sample preparation and loading accommodation) of both methods suggested by the International Society for Rock Mechanics, which are the cracked chevron notched Brazilian disc (CCNBD) method and the notched semi-circular bend (NSCB) method. However, the limited availability of the critical dimensionless stress intensity factor (SIF) values severely hinders the widespread usage of the CCNSCB method. In this study, the critical SIFs are determined for a wide range of CCNSCB specimen geometries via three-dimensional finite element analysis. A relatively large support span in the three point bending configuration was considered because the fracture of the CCNSCB specimen in that situation is finely restricted in the notch ligament, which has been commonly assumed for mode I fracture toughness measurements using chevron notched rock specimens. Both CCNSCB and NSCB tests were conducted to measure the fracture toughness of two different rock types; for each rock type, the two methods produce similar toughness values. Given the reported experimental results, the CCNSCB method can be reliable for characterizing the mode I fracture toughness of rocks.
Zhao, Xiaohua; Wu, Yiping; Rong, Jian; Ma, Jianming
2015-02-01
To develop a practicable and clear guideline for implementing Chevrons on China's highways, it is necessary to understand the effect of Chevrons on driving performance in different roadway geometries. Using a driving simulator, this study tests the effect of China's Chevrons on vehicle speed and lane position on two-lane rural highway horizontal curves with different roadway geometries. The results showed a significant effect of Chevrons on speed reduction, and this function was not significantly affected by curve radius but was statistically affected by curve direction. The speed reduction caused by Chevrons was also significant at the approach of curve, middle of curve and point of tangent. The 85th percentile speed was also markedly lower when Chevrons were present. We also found a significant effect of Chevrons in encouraging participants to drive the vehicle with a more proper lane position at the first half of curves; and this function was slightly affected by curve radius. Meanwhile, the effect of Chevrons on keeping drivers staying in a more stable lane position was also statistically significant at the second half of curves. In sharp curves, the function of Chevrons to make drivers keep a stable lane position was lost. Besides, the impact of curve direction on the function of Chevrons on lane position was always present, and drivers would drive slightly away from Chevrons. Regardless of the curve radius, China's Chevrons at horizontal curves provide an advance warning, speed control and lane position guide for traffic on the nearside of Chevrons. Besides, combing with the function of Chevrons on preventing excessive speed and the benefit to make drivers keep a more proper lane position, China's Chevrons appear to be of great benefit to reduce crashes (e.g., run-off-road) in curves. Copyright © 2014 Elsevier Ltd. All rights reserved.
Phi-value analysis of apo-azurin folding: comparison between experiment and theory.
Zong, Chenghang; Wilson, Corey J; Shen, Tongye; Wolynes, Peter G; Wittung-Stafshede, Pernilla
2006-05-23
Pseudomonas aeruginosa azurin is a 128-residue beta-sandwich metalloprotein; in vitro kinetic experiments have shown that it folds in a two-state reaction. Here, we used a variational free energy functional to calculate the characteristics of the transition state ensemble (TSE) for folding of the apo-form of P. aeruginosa azurin and investigate how it responds to thermal and mutational changes. The variational method directly yields predicted chevron plots for wild-type and mutant apo-forms of azurin. In parallel, we performed in vitro kinetic-folding experiments on the same set of azurin variants using chemical perturbation. Like the wild-type protein, all apo-variants fold in apparent two-state reactions both in calculations and in stopped-flow mixing experiments. Comparisons of phi (phi) values determined from the experimental and theoretical chevron parameters reveal an excellent agreement for most positions, indicating a polarized, highly structured TSE for folding of P. aeruginosa apo-azurin. We also demonstrate that careful analysis of side-chain interactions is necessary for appropriate theoretical description of core mutants.
Jet Engine Exhaust Nozzle Flow Effector
NASA Technical Reports Server (NTRS)
Turner, Travis L. (Inventor); Cano, Roberto J. (Inventor); Silox, Richard J. (Inventor); Buehrle, Ralph D. (Inventor); Cagle, Christopher M. (Inventor); Cabell, Randolph H. (Inventor); Hilton, George C. (Inventor)
2014-01-01
A jet engine exhaust nozzle flow effector is a chevron formed with a radius of curvature with surfaces of the flow effector being defined and opposing one another. At least one shape memory alloy (SMA) member is embedded in the chevron closer to one of the chevron's opposing surfaces and substantially spanning from at least a portion of the chevron's root to the chevron's tip.
Jet Engine Exhaust Nozzle Flow Effector
NASA Technical Reports Server (NTRS)
Turner, Travis L. (Inventor); Buehrle, Ralph D. (Inventor); Silcox, Richard J. (Inventor); Cagle, Christopher M. (Inventor); Cabell, Randolph H. (Inventor); Hilton, George C. (Inventor); Cano, Roberto J. (Inventor)
2011-01-01
A jet engine exhaust nozzle flow effector is a chevron formed with a radius of curvature with surfaces of the flow effector being defined and opposing one another. At least one shape memory alloy (SMA) member is embedded in the chevron closer to one of the chevron's opposing surfaces and substantially spanning from at least a portion of the chevron's root to the chevron's tip.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-11-17
An allegation was made to the Office of Inspector General (OIG) that the integrity of the Department of Energy`s (DOE) unsolicited proposal review process may have been compromised by the actions of a former Deputy Secretary of Energy and his Executive Assistant during the review of an unsolicited proposal received from Chevron U.S.A. Production Company (Chevron) in may 1993. The Chevron unsolicited proposal was for the management and operation of DOE`s Elk Hills Naval Petroleum Reserve (Elk Hills), located near Bakersfield, California. Chevron submitted the unsolicited proposal on May 19, 1993. DOE formally rejected Chevron`s unsolicited proposal in May 1995.more » Although Chevron`s unsolicited proposal was eventually rejected by DOE, the complainant specifically alleged that the {open_quotes}sanctity, integrity, and sensitivity{close_quotes} of the unsolicited proposal review process had been breached in meetings during the Fall of 1993 between Chevron officials, the Deputy Secretary of Energy (Deputy Secretary), and his Executive Assistant. Based on our review of the allegation, we identified the following issue as the focus of our inspection.« less
An MDOE Investigation of Chevrons for Supersonic Jet Noise Reduction
NASA Technical Reports Server (NTRS)
Henderson, Brenda; Bridges, James
2010-01-01
The impact of chevron design on the noise radiated from heated, overexpanded, supersonic jets is presented. The experiments used faceted bi-conic convergent-divergent nozzles with design Mach numbers equal to 1.51 and 1.65. The purpose of the facets was to simulate divergent seals on a military style nozzle. The nozzle throat diameter was equal to 4.5 inches. Modern Design of Experiment (MDOE) techniques were used to investigate the impact of chevron penetration, length, and width on the resulting acoustic radiation. All chevron configurations used 12 chevrons to match the number of facets in the nozzle. Most chevron designs resulted in increased broadband shock noise relative to the baseline nozzle. In the peak jet noise direction, the optimum chevron design reduced peak sound pressure levels by 4 dB relative to the baseline nozzle. The penetration was the parameter having the greatest impact on radiated noise at all observation angles. While increasing chevron penetration decreased acoustic radiation in the peak jet noise direction, broadband shock noise was adversely impacted. Decreasing chevron length increased noise at most observation angles. The impact of chevron width on radiated noise depended on frequency and observation angle.
Methods for the accurate estimation of confidence intervals on protein folding ϕ-values
Ruczinski, Ingo; Sosnick, Tobin R.; Plaxco, Kevin W.
2006-01-01
ϕ-Values provide an important benchmark for the comparison of experimental protein folding studies to computer simulations and theories of the folding process. Despite the growing importance of ϕ measurements, however, formulas to quantify the precision with which ϕ is measured have seen little significant discussion. Moreover, a commonly employed method for the determination of standard errors on ϕ estimates assumes that estimates of the changes in free energy of the transition and folded states are independent. Here we demonstrate that this assumption is usually incorrect and that this typically leads to the underestimation of ϕ precision. We derive an analytical expression for the precision of ϕ estimates (assuming linear chevron behavior) that explicitly takes this dependence into account. We also describe an alternative method that implicitly corrects for the effect. By simulating experimental chevron data, we show that both methods accurately estimate ϕ confidence intervals. We also explore the effects of the commonly employed techniques of calculating ϕ from kinetics estimated at non-zero denaturant concentrations and via the assumption of parallel chevron arms. We find that these approaches can produce significantly different estimates for ϕ (again, even for truly linear chevron behavior), indicating that they are not equivalent, interchangeable measures of transition state structure. Lastly, we describe a Web-based implementation of the above algorithms for general use by the protein folding community. PMID:17008714
Outcomes in chevron osteotomy for Hallux Valgus in a large cohort.
van Groningen, Bart; van der Steen, M C Marieke; Reijman, Max; Bos, Janneke; Hendriks, Johannes G E
2016-12-01
Clinical and radiological related outcomes have been reported for Chevron osteotomy as correction for mild to moderate hallux valgus, but only for relatively small patient series. Moreover, evaluation of the patient's point of view has mostly been conducted by means of more physician-based outcome measures. The goal of this study was to evaluate the effect of the Chevron osteotomy for hallux valgus on patients' daily lives using the Foot and Ankle Outcome Score (FAOS) as a validated and a hallux valgus specific patient reported outcome measure (PROM). Secondary outcome measures were radiological correction, complication rate, and re-operations. All 438 Chevron procedures (336 patients), at two surgical hospital sites in the period between January 2010 and October 2014, were retrospectively evaluated with a follow-up of at least 6 months. Patients were invited to fill in a cross-sectional online FAOS. For the FAOS, a total response of 60% was achieved. The FAOS ranged between 71 and 88 with a follow-up of on average 36 months. Patients with an undercorrection of their hallux valgus (11.6% of the procedures) scored significantly lower on three subscales of the FAOS (range between 61 and 77 versus 72-84). Patients who had a reoperation (12.6% of the procedures) also scored significantly lower on four subscales: 58-100 versus 73-89. Postoperative radiological measurements improved significantly with a mean difference of 6.1 (5.9; 6.4) degrees for the intermetatarsal angle and 13.7 (13.0; 14.5) degrees for the hallux valgus angle. In this large study cohort, Chevron osteotomy for hallux valgus offers good PROM scores on FAOS. These scores were significantly lower in patients with radiological undercorrection or with a reoperation. Results of the FAOS appear to modulate with physician based outcomes and therapeutic incidents. Improvement of outcome may therefore well be possible by increased attention on these surgical details. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kaya, Hüseyin; Liu, Zhirong; Chan, Hue Sun
2005-01-01
It has been demonstrated that a “near-Levinthal” cooperative mechanism, whereby the common Gō interaction scheme is augmented by an extra favorability for the native state as a whole, can lead to apparent two-state folding/unfolding kinetics over a broad range of native stabilities in lattice models of proteins. Here such a mechanism is shown to be generalizable to a simplified continuum (off-lattice) Langevin dynamics model with a Cα protein chain representation, with the resulting chevron plots exhibiting an extended quasilinear regime reminiscent of that of apparent two-state real proteins. Similarly high degrees of cooperativity are possible in Gō-like continuum models with rudimentary pairwise desolvation barriers as well. In these models, cooperativity increases with increasing desolvation barrier height, suggesting strongly that two-state-like folding/unfolding kinetics would be achievable when the pairwise desolvation barrier becomes sufficiently high. Besides cooperativity, another generic folding property of interest that has emerged from published experiments on several apparent two-state proteins is that their folding relaxation under constant native stability (isostability) conditions is essentially Arrhenius, entailing high intrinsic enthalpic folding barriers of ∼17–30 kcal/mol. Based on a new analysis of published data on barnase, here we propose that a similar property should also apply to a certain class of non-two-state proteins that fold with chevron rollovers. However, several continuum Gō-like constructs considered here fail to predict any significant intrinsic enthalpic folding barrier under isostability conditions; thus the physical origin of such barriers in real proteins remains to be elucidated. PMID:15863486
The use of nested chevron rails in a distributed energy store railgun
NASA Astrophysics Data System (ADS)
Marshall, R. A.
1984-03-01
It is pointed out that the large amounts of energy required by electromagnetic launchers will necessitate that energy stores be distributed along their length. The nested chevron rail construction will make it possible for a railgun launcher to be produced in which most of the switching requirements for the launcher/energy store system will be met automatically. Each nested chevron-shaped conductor will be electrically insulated from its neighbors, and each opposing chevron pair (one on each rail) will be connected to the terminals of one energy store (Marshall, 1982). It is explained that as the projectile moves down the railgun the chevrons and associated energy stores at first are unaffected by the approach. At this time the inductors can be charged, and any other preliminary operation can be performed. When the armature comes into contact with the Nth chevron, charge begins to flow from the Nth energy storage system; it flows through one chevron, into the armature, out of the armature into the other chevron, and from that chevron back to the energy storage system.
Glazebrook, Mark; Copithorne, Peter; Boyd, Gordon; Daniels, Timothy; Lalonde, Karl-André; Francis, Patricia; Hickey, Michael
2014-10-01
Hallux valgus with an increased intermetatarsal angle is usually treated with a proximal metatarsal osteotomy. The proximal chevron osteotomy is commonly used but is technically difficult. This study compares the proximal opening wedge osteotomy of the first metatarsal with the proximal chevron osteotomy for the treatment of hallux valgus with an increased intermetatarsal angle. This prospective, randomized multicenter (three-center) study was based on the clinical outcome scores of the Short Form-36, the American Orthopaedic Foot & Ankle Society forefoot questionnaire, and the visual analog scale for pain, activity, and patient satisfaction. Subjects were assessed prior to surgery and at three, six, and twelve months postoperatively. Surgeon preference was evaluated based on questionnaires and the operative times required for each procedure. No significant differences were found for any of the patients' clinical outcome measurements between the two procedures. The proximal opening wedge osteotomy was found to lengthen, and the proximal chevron osteotomy was found to shorten, the first metatarsal. The intermetatarsal angles improved (decreased) significantly, from 14.8° ± 3.2° to 9.1° ± 2.9 (mean and standard deviation) after a proximal opening wedge osteotomy and from 14.6° ± 3.9° to 11.3° ± 4.0° after a proximal chevron osteotomy (p < 0.05 for both). Operative time required for performing a proximal opening wedge osteotomy is similar to that required for performing a proximal chevron osteotomy (mean and standard deviation, 67.1 ± 16.5 minutes compared with 69.9 ± 18.6 minutes; p = 0.510). Opening wedge and proximal chevron osteotomies have comparable radiographic outcomes and comparable clinical outcomes for pain, satisfaction, and function. The proximal opening wedge osteotomy lengthens, and the proximal chevron osteotomy shortens, the first metatarsal. The proximal opening wedge osteotomy was subjectively less technically demanding and was preferred by the orthopaedic surgeons in this study. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
78 FR 69659 - Chevron U.S.A. Inc. v. Kinder Morgan Louisiana Pipeline LLC; Notice of Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-20
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RP14-161-000] Chevron U.S.A... Commission (Commission), 18 CFR 385.206, Chevron U.S.A. Inc. (Chevron or Complainant), filed a complaint..., Commission policy, and contractual obligations. [[Page 69660
Jeuken, Ralph M; Schotanus, Martijn G M; Kort, Nanne P; Deenik, Axel; Jong, Bob; Hendrickx, Roel P M
2016-07-01
Hallux valgus is one of the most common foot deformities. This long-term follow-up study compared the results of 2 widely used operative treatments for hallux valgus: the scarf and chevron osteotomy. Conventional weight bearing anteroposterior (AP) radiographs of the foot were made for evaluating the intermetatarsal angle and hallux valgus angle. For clinical evaluation, the American Orthopaedic Foot & Ankle Society (AOFAS) rating system for the hallux metatarsophalangeal-interphalangeal scale was used together with physical examination of the foot. These data were compared with the results from the original study. The Short Form 36 questionnaire, the Manchester-Oxford Foot Questionnaire (MOXFQ), and a general questionnaire including a visual analog scale (VAS) pain score were used for subjective evaluation. The primary outcome measures were the radiologic recurrence of hallux valgus and reoperation rate of the same toe. Secondary outcome measures were the results from the radiographs and subjective and clinical evaluation. The response rate was 76% at the follow-up of 14 years; in the chevron group, 37 feet were included compared with 36 feet in the scarf group. Twenty-eight feet in the chevron group and 27 in the scarf group developed recurrence of hallux valgus (P = .483). One patient in the scarf group had a reoperation of the same toe compared with none in the chevron group (P = .314). Current VAS pain scores and results from the SF-36, MOXFQ, and AOFAS did not significantly differ between groups. Both techniques showed similar results after 2 years of follow-up. At 14 years of follow-up, neither technique was superior in preventing recurrence. Level II, randomized controlled trial. © The Author(s) 2016.
Fluidic Chevrons for Jet Noise Reduction
NASA Technical Reports Server (NTRS)
Kinzie, Kevin; Henderson, Brenda; Whitmire, Julia
2004-01-01
Chevron mixing devices are used to reduce noise from commercial separate-flow turbofan engines. Mechanical chevron serrations at the nozzle trailing edge generate axial vorticity that enhances jet plume mixing and consequently reduces far-field noise. Fluidic chevrons generated with air injected near the nozzle trailing edge create a vorticity field similar to that of the mechanical chevrons and allow more flexibility in controlling acoustic and thrust performance than a passive mechanical design. In addition, the design of such a system has the future potential for actively controlling jet noise by pulsing or otherwise optimally distributing the injected air. Scale model jet noise experiments have been performed in the NASA Langley Low Speed Aeroacoustic Wind Tunnel to investigate the fluidic chevron concept. Acoustic data from different fluidic chevron designs are shown. Varying degrees of noise reduction are achieved depending on the injection pattern and injection flow conditions. CFD results were used to select design concepts that displayed axial vorticity growth similar to that associated with mechanical chevrons and qualitatively describe the air injection flow and the impact on acoustic performance.
Testing of SMA-enabled Active Chevron Prototypes under Representative Flow Conditions
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Cabell,Randolph H.; Cano, Roberto J.; Silcox, Richard J.
2008-01-01
Control of jet noise continues to be an important research topic. Exhaust-nozzle chevrons have been shown to reduce jet noise, but parametric effects are not well understood. Additionally, thrust loss due to chevrons at cruise suggests significant benefit from active chevrons. The focus of this study is development of an active chevron concept for the primary purpose of parametric studies for jet noise reduction in the laboratory and secondarily for technology development to leverage for full scale systems. The active chevron concept employed in this work consists of a laminated composite structure with embedded shape memory alloy (SMA) actuators, termed a SMA hybrid composite (SMAHC). SMA actuators are embedded on one side of the neutral axis of the structure such that thermal excitation, via joule heating, generates a moment and deflects the structure. The performance of two active chevron concepts is demonstrated in the presence of representative flow conditions. One of the concepts is shown to possess significant advantages for the proposed application and is selected for further development. Fabrication and design changes are described and shown to produce a chevron prototype that meets the performance objectives.
Yong, Shan; JingZhou, Zhang; Yameng, Wang
2014-11-01
To improve the performance of the afterburner for the turbofan engine, an innovative type of mixer, namely, the chevron mixer, was considered to enhance the mixture between the core flow and the bypass flow. Computational fluid dynamics (CFD) simulations investigated the aerodynamic performances and combustion characteristics of the chevron mixer inside a typical afterburner. Three types of mixer, namely, CC (chevrons tilted into core flow), CB (chevrons tilted into bypass flow), and CA (chevrons tilted into core flow and bypass flow alternately), respectively, were studied on the aerodynamic performances of mixing process. The chevrons arrangement has significant effect on the mixing characteristics and the CA mode seems to be advantageous for the generation of the stronger streamwise vortices with lower aerodynamic loss. Further investigations on combustion characteristics for CA mode were performed. Calculation results reveal that the local temperature distribution at the leading edge section of flame holder is improved under the action of streamwise vortices shedding from chevron mixers. Consequently, the combustion efficiency increased by 3.5% compared with confluent mixer under the same fuel supply scheme.
Rectus abdominis atrophy after ventral abdominal incisions: midline versus chevron.
Vigneswaran, Y; Poli, E; Talamonti, M S; Haggerty, S P; Linn, J G; Ujiki, M B
2017-08-01
Although many outcomes have been compared between a midline and chevron incision, this is the first study to examine rectus abdominis atrophy after these two types of incisions. Patients undergoing open pancreaticobiliary surgery between 2007 and 2011 at our single institution were included in this study. Rectus abdominis muscle thickness was measured on both preoperative and follow-up computed tomography (CT) scans to calculate percent atrophy of the muscle after surgery. At average follow-up of 24.5 and 19.0 months, respectively, rectus abdominis atrophy was 18.9% greater in the chevron (n = 30) than in the midline (n = 180) group (21.8 vs. 2.9%, p < 0.0001). Half the patients with a chevron incision had >20% atrophy at follow-up compared with 10% with a midline incision [odds ratio (OR) 9.0, p < 0.0001]. No significant difference was observed in incisional hernia rates or wound infections between groups. In this study, chevron incisions resulted in seven times more atrophy of the rectus abdominis compared with midline incisions. The long-term effects of transecting the rectus abdominis and disrupting its innervation creates challenging abdominal wall pathology. Atrophy of the abdominal wall can not be readily fixed with an operation, and this significant side effect of a transverse incision should be factored into the surgeon's decision-making process when choosing a transverse over a midline incision.
Bai, Long Bin; Lee, Keun Bae; Seo, Chang Young; Song, Eun Kyoo; Yoon, Taek Rim
2010-08-01
Distal chevron osteotomy has been widely employed to treat mild to moderate hallux valgus deformity. The purpose of the present study was to evaluate the outcomes of distal chevron osteotomy with a distal soft tissue procedure for the correction of moderate to severe hallux valgus. We reviewed 76 patients (86 feet) that underwent distal chevron osteotomy with a distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. At a mean followup of 31 months, all patients were evaluated using subjective, objective and radiographic measurements. Ninety-four percent of the patients were very satisfied or satisfied. Average AOFAS score improved from 54.7 points preoperatively to 92.9 at final followup. Average hallux valgus angle changed from 36.2 degrees preoperatively to 12.4 degrees at final followup, and average first-second intermetatarsal angle changed from 17.1 to 7.3 degrees. Average tibial sesamoid position changed from 2.4 preoperatively to 1.2 at final followup. Dorsal angulation of the head was observed in two feet, and plantaflexion of the head in four feet. There were no cases of avascular necrosis of the metatarsal head. Our results indicate that distal chevron osteotomy with a distal soft tissue procedure provides an effective and reliable means of correcting moderate to severe hallux valgus deformity, and that it does so with high levels of patient satisfaction and low incidence of complications.
Flight Test Results for Uniquely Tailored Propulsion-Airframe Aeroacoustic Chevrons: Community Noise
NASA Technical Reports Server (NTRS)
Nesbitt, Eric; Mengle, Vinod; Czech, Michael; Callendar, Bryan; Thomas, Russ
2006-01-01
The flow/acoustic environment around the jet exhaust of an engine when installed on an airplane, say, under the wing, is highly asymmetric due to the pylon, the wing and the high-lift devices. Recent scale model tests have shown that such Propulsion Airframe Aeroacoustic (PAA) interactions and the jet mixing noise can be reduced more than with conventional azimuthally uniform chevrons by uniquely tailoring the chevrons to produce enhanced mixing near the pylon. This paper describes the community noise results from a flight test on a large twin-engine airplane using this concept of azimuthally varying chevrons for engines installed under the wing. Results for two different nozzle configurations are described: azimuthally varying "PAA T-fan" chevrons on the fan nozzle with a baseline no-chevron core nozzle and a second with PAA T-fan chevrons with conventional azimuthally uniform chevrons on the core nozzle. We analyze these test results in comparison to the baseline no-chevron nozzle on both spectral and integrated power level bases. The study focuses on the peak jet noise reduction and the effects at high frequencies for typical take-off power settings. The noise reduction and the absolute noise levels are then compared to model scale results. The flight test results verify that the PAA T-fan nozzles in combination with standard core chevron nozzles can, indeed, give a reasonable amount of noise reduction at low frequencies without high-frequency lift during take-off conditions and hardly any impact on the cruise thrust coefficient.
33 CFR 147.825 - Chevron Genesis Spar safety zone.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Chevron Genesis Spar safety zone... (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.825 Chevron Genesis Spar safety zone. (a) Description. The Chevron Genesis Spar, Green Canyon 205A (GC205A), is located at position 27°46′46.365″ N, 90...
33 CFR 147.825 - Chevron Genesis Spar safety zone.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Chevron Genesis Spar safety zone... (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.825 Chevron Genesis Spar safety zone. (a) Description. The Chevron Genesis Spar, Green Canyon 205A (GC205A), is located at position 27°46′46.365″ N, 90...
33 CFR 147.825 - Chevron Genesis Spar safety zone.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Chevron Genesis Spar safety zone... (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.825 Chevron Genesis Spar safety zone. (a) Description. The Chevron Genesis Spar, Green Canyon 205A (GC205A), is located at position 27°46′46.365″ N, 90...
33 CFR 147.825 - Chevron Genesis Spar safety zone.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Chevron Genesis Spar safety zone... (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES SAFETY ZONES § 147.825 Chevron Genesis Spar safety zone. (a) Description. The Chevron Genesis Spar, Green Canyon 205A (GC205A), is located at position 27°46′46.365″ N, 90...
Chevron formation of the zebrafish muscle segments
Rost, Fabian; Eugster, Christina; Schröter, Christian; Oates, Andrew C.; Brusch, Lutz
2014-01-01
The muscle segments of fish have a folded shape, termed a chevron, which is thought to be optimal for the undulating body movements of swimming. However, the mechanism shaping the chevron during embryogenesis is not understood. Here, we used time-lapse microscopy of developing zebrafish embryos spanning the entire somitogenesis period to quantify the dynamics of chevron shape development. By comparing such time courses with the start of movements in wildtype zebrafish and analysing immobile mutants, we show that the previously implicated body movements do not play a role in chevron formation. Further, the monotonic increase of chevron angle along the anteroposterior axis revealed by our data constrains or rules out possible contributions by previously proposed mechanisms. In particular, we found that muscle pioneers are not required for chevron formation. We put forward a tension-and-resistance mechanism involving interactions between intra-segmental tension and segment boundaries. To evaluate this mechanism, we derived and analysed a mechanical model of a chain of contractile and resisting elements. The predictions of this model were verified by comparison with experimental data. Altogether, our results support the notion that a simple physical mechanism suffices to self-organize the observed spatiotemporal pattern in chevron formation. PMID:25267843
NASA Astrophysics Data System (ADS)
Remo, Jonathan W. F.; Khanal, Anish; Pinter, Nicholas
2013-09-01
Blunt-nosed chevron dikes, a new invention now being widely constructed on the Middle Mississippi River (MMR), have been justified as a tool for enhancing physical-aquatic habitat. Chevron dikes were initially designed to concentrate flow, induce channel scour, and thus facilitate river navigation. More recently, these structures have been justified, in part, for promoting habitat heterogeneity. The ability of chevrons to create and diversify physical-aquatic habitat, however, has not been empirically evaluated. To assess the ability of chevrons to create and diversify physical-aquatic habitat, we compiled hydrologic and geospatial data for three channel reference conditions along a 2.0 km (∼140 ha) reach of the MMR where three chevrons were constructed in late 2007. We used the hydrologic and hydraulic data to construct detailed 2-D hydrodynamic models for three reference condition: historic (circa 1890), pre-chevron, and post-chevron channel conditions. These models documented changes in depths and flow dynamics for a wide range of in-channel discharges. Depth-velocity habitat classes were used to assess change in physical-aquatic habitat patches and spatial statistical tools in order to evaluate the reach-scale habitat patch diversity. Comparisons of pre- and post-chevron conditions revealed increases in deep to very deep (>3.0 m) areas of slow moving (<0.6 m/s) water downstream of these structures under emergent flow conditions (⩽1.5 × mean annual flow [MAF]). Chevron construction added up to 7.6 ha of potential over-wintering habitat (deep [>3.0 m], low velocity [<0.6 m/s]). Chevron construction also created some (0.8-3.8 ha) shallow-water habitat (0-1.5 m depth with a 0-0.6 m/s velocity) for flows ⩽2.0 × MAF and contributed to an 8-35% increase in physical-aquatic-habitat diversity compared to pre-chevron channel conditions. However, modeling of the historic reference condition (less engineered channel, circa 1890) revealed that the historical physical-aquatic-habitat mosaic consisted of a wider and shallower channel with: 45-390% more shallow-water habitat (2.4-11.0 ha) and 22-83% more physical-aquatic-habitat diversity, but little over-wintering habitat (<0.4 ha). Thus, while chevron construction increased over-wintering habitat, shallow-water habitat, and physical-aquatic-habitat diversity relative to the pre-chevron channel condition, these types of physical-aquatic habitat are different from what was historically found along this reach. Constructing chevrons dikes, or other dike-like structures in the river channel, can change the physical-aquatic habitat patch mosaic and likely contribute to small increases in physical-aquatic-habitat heterogeneity. However, differences in the types, quantity, and diversity of physical-aquatic-habitat patches created by chevron dikes in comparison to the physical-aquatic-habitat patch mosaic of historic channel underscore the need for additional research to determine which physical-aquatic-habitat patches are critical for the recovery of endangered or threatened aquatic organisms.
High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement
NASA Technical Reports Server (NTRS)
Quackenbush, Todd R.; McKillip, Robert M., Jr.
2011-01-01
One of key NASA goals is to develop and integrate noise reduction technology to enable unrestricted air transportation service to all communities. One of the technical priorities of this activity has been to account for and reduce noise via propulsion/airframe interactions, identifying advanced concepts to be integrated with the airframe to mitigate these noise-producing mechanisms. An adaptive geometry chevron using embedded smart structures technology offers the possibility of maximizing engine performance while retaining and possibly enhancing the favorable noise characteristics of current designs. New high-temperature shape memory alloy (HTSMA) materials technology enables the devices to operate in both low-temperature (fan) and high-temperature (core) exhaust flows. Chevron-equipped engines have demonstrated reduced noise in testing and operational use. It is desirable to have the noise benefits of chevrons in takeoff/landing conditions, but have them deployed into a minimum drag position for cruise flight. The central feature of the innovation was building on rapidly maturing HTSMA technology to implement a next-generation aircraft noise mitigation system centered on adaptive chevron flow control surfaces. In general, SMA-actuated devices have the potential to enhance the demonstrated noise reduction effectiveness of chevron systems while eliminating the associated performance penalty. The use of structurally integrated smart devices will minimize the mechanical and subsystem complexity of this implementation. The central innovations of the effort entail the modification of prior chevron designs to include a small cut that relaxes structural stiffness without compromising the desired flow characteristics over the surface; the reorientation of SMA actuation devices to apply forces to deflect the chevron tip, exploiting this relaxed stiffness; and the use of high-temperature SMA (HTSMA) materials to enable operation in the demanding core chevron environment. The overall conclusion of these design studies was that the cut chevron concept is a critical enabling step in bringing the variable geometry core chevron within reach. The presence of the cut may be aerodynamically undesirable in some respects, but it is present only when the chevron is not immersed in the core jet exhaust. When deployed, the gap closes as the chevron tip enters the high-speed, high-temperature core stream. Aeroacoustic testing and flow visualization support the contention that this cut is inconsequential to chevron performance.
Numerical and experimental evaluations of the flow past nested chevrons
NASA Technical Reports Server (NTRS)
Foss, J. F.; Foss, J. K.; Spalart, P. R.
1989-01-01
An effort is made to contribute to the development of CFD by relating the successful use of vortex dynamics in the computation of the pressure drop past a planar array of chevron-shaped obstructions. An ensemble of results was used to compute the loss coefficient k, stimulating an experimental program for the assessment of the measured loss coefficient for the same geometry. The most provocative result of this study has been the representation of kinetic energy production in terms of vorticity source terms.
Chevron facility focused on commercial orifice-meter research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E.H.; Ferguson, K.R.
1987-07-27
Research to determine the accuracy of commercial orifice meters for custody-transfer measurement has indicated that high-volume gas meters can be flow-proven while in such service. The research further yielded more accurate orifice-meter discharge coefficient equations (at Reynolds numbers greater than 4,000,000) than current equations of the International Standards Organization (ISO) and the American Petroleum Institute (API). These are partial findings of a major study conducted by Chevron Oil Field Research Co. at its Venice, La., calibration facility.
NASA Technical Reports Server (NTRS)
Bubsey, R. T.; Orange, T. W.; Pierce, W. S.; Shannon, J. L., Jr.
1992-01-01
A set of equations are presented describing certain fracture mechanics parameters for chevron notch bar and rod specimens. They are developed by fitting compliance calibration data reported earlier. The equations present the various parameters in their most useful forms. The data encompass the entire range of the specimen geometries most commonly used. Their use will facilitate the testing and analysis of brittle metals, ceramics, and glasses.
The Bare Area of the Proximal Ulna: An Anatomic Study With Relevance to Chevron Osteotomy.
Ao, Rongguang; Zhang, Xu; Li, Dejian; Chen, Fancheng; Zhou, Jianhua; Yu, Baoqing
2017-06-01
A chevron osteotomy of the ulna is widely used to obtain intra-articular access to the elbow in the treatment of type C distal humerus fractures. The trochlear notch of the proximal ulna is divided into 2 articular parts by the "bare area." Ideally, the olecranon osteotomy should be centered on the bare area to minimize damage to the joint cartilage. The goals of this study were to describe the anatomy of the bare area and design an ideal chevron-shaped osteotomy. We dissected 38 cadaver elbows and measured the width of the bare area, the distance between the tip of the triceps insertion and the area on the olecranon cortex corresponding to the bare area. We then designed a chevron osteotomy to stay within the bare area and measured the distance from the tip of the triceps insertion to the osteotomy apex as well as the angle of the osteotomy plane and the angle of the chevron cuts. The bare area existed in all 38 cadavers. The mean longitudinal and transverse widths were 4.0 mm (range, 1.0-8.6 mm) and 19.0 mm (range, 16.9-23.8 mm), respectively. The mean distance between the tip of the triceps insertion and the area on the olecranon cortex corresponding to the bare area was 19.0 mm (range, 16.0-23.0 mm). The mean transverse and longitudinal widths of the cortical notch were 3.0 mm (range, 1.6-4.5 mm) and 8.0 mm (range, 6.5-14.8 mm), respectively. The mean distance between the tip of the triceps insertion and the osteotomy apex was 22.0 mm (range, 18.0-24.0 mm) and the mean angle between the osteotomy surface and the vertical plane corresponding to the tangent plane was 20° (range, 10° to 25°). The mean angle of the V shape was 140° (range, 130° to 150°). Using the narrowest edge lacking cartilage (lateral or medial side) as a point of reference to locate the bare area, the designed chevron osteotomy entered the joint in the bare area in most specimens and decreased associated damage to the joint cartilage. This study describes the anatomy of the bare area and the design of the ideal chevron-shaped osteotomy to treat type C distal humerus fractures. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
75 FR 79367 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-20
..., December 28, 2010. Docket Numbers: ER10-2785-004. Applicants: Chevron Coalinga Energy Company. Description: Chevron Coalinga Energy Company submits tariff filing per 35: Chevron Coalinga Energy Company Tariff to be...
Lee, Ho-Jin; Chung, Jin-Wha; Chu, In-Tak; Kim, Yoon-Chung
2010-04-01
A lateral soft tissue release is often performed with distal chevron osteotomy for the correction of hallux valgus deformities. However, many complications of lateral soft tissue release have been reported. To define the necessity of lateral soft tissue release, the authors compared the clinical and radiographic results of distal chevron osteotomy with and without it. 86 consecutive patients (152 feet) were enrolled in this prospective study. In Group A, 45 patients (74 feet) underwent a chevron osteotomy with lateral soft tissue release. In Group B, 41 patients (78 feet) underwent a chevron osteotomy without it. Mean followup was 1.7 years and 2.1 years, respectively. The hallux valgus angle (HVA) and intermetatarsal angle (IMA), and AOFAS score were measured preoperatively, and 1-year followup postoperatively and complications were evaluated. The change in HVA, IMA and AOFAS score were insignificant (p > 0.05) between Group A and Group B, however, the range of motion of the first metatarsophalangeal joint was significantly less in Group A (p < 0.05). Complications of digital neuritis and cosmetically dissatisfied scarring of the dorsal web space were seen only in Group A. No cases had avascular necrosis of the metatarsal head, malunion or nonunion. Lateral soft tissue release may not be needed for mild or moderate hallux valgus deformities which may prevent decreased range of motion of the first metatarsophalangeal joint, neuritis of dorsal or plantar lateral digital nerve and cosmetic dissatisfaction of a dorsal scar.
Comparative study of scarf and extended chevron osteotomies for correction of hallux valgus.
Vopat, Bryan G; Lareau, Craig R; Johnson, Julie; Reinert, Steven E; DiGiovanni, Christopher W
2013-12-01
Scarf and chevron osteotomies are two described treatments for the correction of hallux valgus deformity, but they have traditionally been employed for different levels of severity. We hypothesized that there would be no statistically significant difference between the results of these two treatments. This study is a retrospective review of 70 consecutive patients treated operatively for moderate and severe hallux valgus malalignment. The two groups based on their operative treatment: scarf osteotomy (Group A) and extended chevron osteotomy (Group B). Preoperative and postoperative hallux valgus angle (HVA), intermetatarsal angle and distal metatarsal articular angle (DMAA) were measured at final follow-up. Charts were also assessed to determine the postoperative rate of satisfaction, stiffness, and pain. There were no statistically significant differences between Groups A and B with regard to the HVA preoperatively and postoperatively. The DMAA was statistically significantly higher for Group B both preoperatively (p=0.0403) and postoperatively (p<0.0001). The differences in HVA correction and IMA correction were not statistically significant. There were no statistically significant differences with regard to post-operative stiffness, pain, and satisfaction. The scarf and extended chevron osteotomies are capable of adequately reducing the HVA and IMA in patients with moderate to severe hallux valgus. These two techniques yielded similar patient outcomes in terms of stiffness, pain and satisfaction. Based on these results, we recommend both the scarf and extended chevron osteotomy as acceptable forms of correction for moderate to severe hallux valgus.
Chevron formation of the zebrafish muscle segments.
Rost, Fabian; Eugster, Christina; Schröter, Christian; Oates, Andrew C; Brusch, Lutz
2014-11-01
The muscle segments of fish have a folded shape, termed a chevron, which is thought to be optimal for the undulating body movements of swimming. However, the mechanism shaping the chevron during embryogenesis is not understood. Here, we used time-lapse microscopy of developing zebrafish embryos spanning the entire somitogenesis period to quantify the dynamics of chevron shape development. By comparing such time courses with the start of movements in wildtype zebrafish and analysing immobile mutants, we show that the previously implicated body movements do not play a role in chevron formation. Further, the monotonic increase of chevron angle along the anteroposterior axis revealed by our data constrains or rules out possible contributions by previously proposed mechanisms. In particular, we found that muscle pioneers are not required for chevron formation. We put forward a tension-and-resistance mechanism involving interactions between intra-segmental tension and segment boundaries. To evaluate this mechanism, we derived and analysed a mechanical model of a chain of contractile and resisting elements. The predictions of this model were verified by comparison with experimental data. Altogether, our results support the notion that a simple physical mechanism suffices to self-organize the observed spatiotemporal pattern in chevron formation. © 2014. Published by The Company of Biologists Ltd.
A review of chevron-notched fracture specimens
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.
1984-01-01
The historical development of chevron notched fracture specimens is reviewed. Stress intensity factors and load line displacement solutions proposed for some of these specimens are compared. The original bend bar configurations up to the present day short rod and bar specimens are reviewed. The results of an analytical round robin that was conducted on chevron-notched specimens are presented. In the round robin, stress-intensity factors for either the chevron notched round rod or square bar specimens were calculated. The consensus stress intensity factor (compliance) solution for these specimens is assessed. The stress intensity factor solutions proposed for three and four point bend chevron notched specimens are reviewed.
Publications - GMC 287 | Alaska Division of Geological & Geophysical
of cuttings from the following wells: Chevron USA Inc. Jeanette Island #1, Chevron USA Inc. Karluk #1 , rock-eval, vitrinite reflectance, and gas chromatography of cuttings from the following wells: Chevron
Crash Modification Factors for Chevrons in Iowa
DOT National Transportation Integrated Search
2018-02-02
Although chevron alignment signs have been utilized for some time along horizontal curves, their effectiveness is not well documented. The Crash Modification Factors Clearinghouse includes crash modification factors (CMFs) for chevrons from 0.41 to 1...
Aeroacoustic Improvements to Fluidic Chevron Nozzles
NASA Technical Reports Server (NTRS)
Henderson, Brenda; Kinzie, Kevin; Whitmire, Julia; Abeysinghe, Amal
2006-01-01
Fluidic chevrons use injected air near the trailing edge of a nozzle to emulate mixing and jet noise reduction characteristics of mechanical chevrons. While previous investigations of "first generation" fluidic chevron nozzles showed only marginal improvements in effective perceived noise levels when compared to nozzles without injection, significant improvements in noise reduction characteristics were achieved through redesigned "second generation" nozzles on a bypass ratio 5 model system. The second-generation core nozzles had improved injection passage contours, external nozzle contour lines, and nozzle trailing edges. The new fluidic chevrons resulted in reduced overall sound pressure levels over that of the baseline nozzle for all observation angles. Injection ports with steep injection angles produced lower overall sound pressure levels than those produced by shallow injection angles. The reductions in overall sound pressure levels were the result of noise reductions at low frequencies. In contrast to the first-generation nozzles, only marginal increases in high frequency noise over that of the baseline nozzle were observed for the second-generation nozzles. The effective perceived noise levels of the new fluidic chevrons are shown to approach those of the core mechanical chevrons.
CFD Analyses and Jet-Noise Predictions of Chevron Nozzles with Vortex Stabilization
NASA Technical Reports Server (NTRS)
Dippold, Vance
2008-01-01
The wind computational fluid dynamics code was used to perform a series of analyses on a single-flow plug nozzle with chevrons. Air was injected from tubes tangent to the nozzle outer surface at three different points along the chevron at the nozzle exit: near the chevron notch, at the chevron mid-point, and near the chevron tip. Three injection pressures were used for each injection tube location--10, 30, and 50 psig-giving injection mass flow rates of 0.1, 0.2, and 0.3 percent of the nozzle mass flow. The results showed subtle changes in the jet plume s turbulence and vorticity structure in the region immediately downstream of the nozzle exit. Distinctive patterns in the plume structure emerged from each injection location, and these became more pronounced as the injection pressure was increased. However, no significant changes in centerline velocity decay or turbulent kinetic energy were observed in the jet plume as a result of flow injection. Furthermore, computational acoustics calculations performed with the JeNo code showed no real reduction in jet noise relative to the baseline chevron nozzle.
NASA Astrophysics Data System (ADS)
Remo, J. W.; Pinter, N.
2012-12-01
Along the Middle Mississippi River (MMR), rehabilitation of aquatic habitat is being undertaken using river-training structures such as the blunt-nose chevron dike. Chevron dikes were initially designed to concentrate flow and thus facilitate river navigation, but this new river-training structure is now justified, in part, as a tool for creating aquatic habitat and promoting habitat heterogeneity. The ability of chevrons to create and diversify physical-aquatic habitat has not been verified. In this study, we used 2-D hydrodynamic modeling and reach-scale habitat metrics to assess changes in physical habitat and habitat heterogeneity for pre-chevron and post-chevron along a 2- km reach of the Mississippi River at St. Louis, MO. A historic reference condition (circa 1890) was also modeled to compare physical habitat in a less engineered river channel versus the new physical-habitat patches created by chevron-dike enhancement. This modeling approach quantified changes in habitat availability and diversity among selected reference conditions for a wide range of in-channel flows. Depth-velocity habitat classes were used for assessment of change in physical-habitat patches, and spatial statistical tools were employed to evaluate the reach-scale habitat patch diversity. Modeling of post-chevron channel conditions revealed increases in deep to very deep (>3.0 m) areas of slow moving (<0.6 m/s) water downstream of these structures under emergent flow conditions (≤ 1.5 x mean annual flow[MAF]) relative to pre-construction conditions. Chevron construction increased potential over-wintering habitat (deep [>3.0 m], low velocity [<0.6 m/s]) by up to 7.6 ha. The addition of the chevrons to the river channel also created some (0.8-3.8 ha) shallow-water habitat (0-1.5 m depth with a 0-0.6 m/s velocity) for flows ≤2.0 x MAF and contributed to an 8-35% increase in physical-habitat diversity compared to pre-chevron channel conditions. Comparison of the historic reference condition (less engineered channel, circa 1890) with the post-chevron channel condition, however, revealed historical conditions consisted of a physical-habitat mosaic comprised of a wider and shallower historic river channel with: very little over-wintering habitat (<0.4 ha), 45-390% more shallow-water habitat (2.4 - 11.0 ha), and 22-83% more physical-habitat diversity. Thus, while chevrons construction within the study reaches increased over-wintering habitat, shallow-water habitat, and physical-habitat diversity relative to the pre-chevron channel condition, the type of physical habitat(s) are different from what was historically found along this reach. Constructing chevrons dikes, or other dike-like structures in the river channel, can change the physical-habitat patch mosaic and likely contribute to small increases in physical-habitat heterogeneity. However, differences in the types, quantity, and diversity of physical-habitat patches created by chevron dikes in comparison to the physical-habitat patch mosaic of historic channel underscore the need for additional research to determine which physical-habitat patches are critical for the recovery of endangered or threatened aquatic organisms.
Chevron versus Mitchell osteotomy in hallux valgus surgery: a comparative study.
Lambers Heerspink, F O; Verburg, H; Reininga, I H F; van Raaij, T M
2015-01-01
Good clinical results have been reported for chevron and Mitchell osteotomies in mild hallux valgus (HV). The primary aim of the present study was to compare first metatarsal shortening after chevron and Mitchell osteotomies in HV. The secondary outcome measures were the degree of valgus correction, metatarsalgia, and patient satisfaction. A total of 84 patients were included in the present study and were treated from 2005 to 2007; 42 patients were in each group. The outcome measurements-first metatarsal length, HV angle, 1-2 intermetatarsal angle, satisfaction, and metatarsalgia-were taken preoperatively and at follow-up. The Mitchell osteotomy resulted in a significantly larger decrease in the first metatarsal length. No significant difference in transfer metatarsalgia was found. Approximately 30% of patients were mildly or not satisfied after HV surgery. Mitchell osteotomy leads to a larger decrease in the first metatarsal length. Patients with metatarsalgia performed poorly, and no significant differences in metatarsalgia were found. Preventing postoperative metatarsalgia is important for a successful outcome after HV surgery. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Welch, Robert B.; Post, Robert B.; Lum, Wayland; Prinzmetal, William
2004-01-01
We examined the apparent dissociation of perceived length and perceived position with respect to the Muller-Lyer (M-L) illusion. With the traditional (two-chevron) figure, participants made accurate open-loop pointing responses at the endpoints of the shaft, despite the presence of a strong length illusion. This apparently non-Euclidean outcome replicated that of Mack, Heuer, Villardi, and Chambers (1985) and Gillam and Chambers (1985) and contradicts any theory of the M-L illusion in which mislocalization of shaft endpoints plays a role. However, when one of the chevrons was removed, a constant pointing error occurred in the predicted direction, as well as a strong length illusion. Thus, with one-chevron stimuli, perceived length and location were no longer completely dissociated. We speculated that the presence of two opposing chevrons suppresses the mislocalizing effects of a single chevron, especially for figures with relatively short shafts.
High Bypass Ratio Jet Noise Reduction and Installation Effects Including Shielding Effectiveness
NASA Technical Reports Server (NTRS)
Thomas, Russell H.; Czech, Michael J.; Doty, Michael J.
2013-01-01
An experimental investigation was performed to study the propulsion airframe aeroacoustic installation effects of a separate flow jet nozzle with a Hybrid Wing Body aircraft configuration where the engine is installed above the wing. Prior understanding of the jet noise shielding effectiveness was extended to a bypass ratio ten application as a function of nozzle configuration, chevron type, axial spacing, and installation effects from additional airframe components. Chevron types included fan chevrons that are uniform circumferentially around the fan nozzle and T-fan type chevrons that are asymmetrical circumferentially. In isolated testing without a pylon, uniform chevrons compared to T-fan chevrons showed slightly more low frequency reduction offset by more high frequency increase. Phased array localization shows that at this bypass ratio chevrons still move peak jet noise source locations upstream but not to nearly the extent, as a function of frequency, as for lower bypass ratio jets. For baseline nozzles without chevrons, the basic pylon effect has been greatly reduced compared to that seen for lower bypass ratio jets. Compared to Tfan chevrons without a pylon, the combination with a standard pylon results in more high frequency noise increase and an overall higher noise level. Shielded by an airframe surface 2.17 fan diameters from nozzle to airframe trailing edge, the T-fan chevron nozzle can produce reductions in jet noise of as much as 8 dB at high frequencies and upstream angles. Noise reduction from shielding decreases with decreasing frequency and with increasing angle from the jet inlet. Beyond an angle of 130 degrees there is almost no noise reduction from shielding. Increasing chevron immersion more than what is already an aggressive design is not advantageous for noise reduction. The addition of airframe control surfaces, including vertical stabilizers and elevon deflection, showed only a small overall impact. Based on the test results, the best overall nozzle configuration design was selected for application to the N2A Hybrid Wing Body concept that will be the subject of the NASA Langley 14 by 22 Foot Subsonic Tunnel high fidelity aeroacoustic characterization experiment. The best overall nozzle selected includes T-fan type chevrons, uniform chevrons on the core nozzle, and no additional pylon of the type that created a strong acoustic effect at lower bypass ratios. The T-fan chevrons are oriented azimuthally away from the ground observer locations. This best overall nozzle compared to the baseline nozzle was assessed, at equal thrust, to produce sufficient installed noise reduction of the jet noise component to enable the N2A HWB to meet NASA s noise goal of 42 dB cumulative below Stage 4.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... facilities permitted under a 1995 Presidential Permit issued to Chevron Pipeline Company (``Chevron... Paso, Texas to the U.S. boundary with Mexico. Through corporate transactions, Chevron assigned the...
PIV Measurements of Chevrons on F400-Series Tactical Aircraft Nozzle Model
NASA Technical Reports Server (NTRS)
Bridges, James; Wernet, Mark P.; Frate, Franco C.
2011-01-01
Reducing noise of tactical jet aircraft has taken on fresh urgency as core engine technologies allow higher specific-thrust engines and as society become more concerned for the health of its military workforce. Noise reduction on this application has lagged the commercial field as incentives for quieting military aircraft have not been as strong as in their civilian counterparts. And noise reduction strategies employed on civilian engines may not be directly applicable due to the differences in exhaust system architecture and mission. For instance, the noise reduction technology of chevrons, examined in this study, will need to be modified to take into account the special features of tactical aircraft nozzles. In practice, these nozzles have divergent slats that are tied to throttle position, and at take off the jet flow is highly overexpanded as the nozzle is optimized for cruise altitude rather than sea level. In simple oil flow visualization experiments conducted at the onset of the current test program flow barely stays attached at end of nozzle at takeoff conditions. This adds a new twist to the design of chevrons. Upon reaching the nozzle exit the flow shrinks inward radially, meaning that for a chevron to penetrate the flow it must extend much farther away from the baseline nozzle streamline. Another wrinkle is that with a variable divergence angle on the nozzle, the effective penetration will differ with throttle position and altitude. The final note of realism introduced in these experiments was to simulate the manner in which bypass flow is bled into the nozzle wall in real engines to cool the nozzle, which might cause very fat boundary layer at exit. These factors, along with several other issues specific to the application of chevrons to convergent-divergent nozzles have been explored with particle image velocimetry measurements and are presented in this paper.
Choi, Gi Won; Kim, Hak Jun; Kim, Taik Seon; Chun, Sung Kwang; Kim, Tae Wan; Lee, Yong In; Kim, Kyoung Ho
2016-01-01
Distal metatarsal osteotomy and the modified McBride procedure have each been used for the treatment of mild to moderate hallux valgus. However, few studies have compared the results of these 2 procedures for mild to moderate hallux valgus. The purpose of the present study was to compare the results of distal chevron osteotomy and the modified McBride procedure for treatment of mild to moderate hallux valgus according to the severity of the deformity. We analyzed the data from 45 patients (49.5%; 48 feet [49.0%]), who had undergone an isolated modified McBride procedure (McBride group), and 46 patients (50.5%; 50 feet [51.0%]), who had a distal chevron osteotomy (chevron group). We subdivided each group into those with mild and moderate deformity and compared the clinical and radiologic outcomes between the groups in relation to the severity of the deformity. The improvements in the American Orthopaedic Foot and Ankle Society scale score and the visual analog scale for pain were significantly better for the chevron group for both mild and moderate deformity. The chevron group experienced significantly greater correction in the hallux valgus angle and intermetatarsal angle for both mild and moderate deformity. The chevron group experienced a significantly greater decrease in the grade of sesamoid displacement for patients with moderate deformity. The McBride group had a greater risk of recurrence than did the chevron group for moderate deformity (odds ratio 14.00, 95% confidence interval 3.91 to 50.06, p < .001). The results of the present study have demonstrated the superiority of the distal chevron osteotomy over the modified McBride procedure for mild to moderate deformity. For patients with moderate deformity, the McBride group had a greater risk of hallux valgus recurrence than did the distal chevron group. Therefore, we recommend distal chevron osteotomy rather than a modified McBride procedure for the treatment of mild and moderate hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Computational Analysis of a Chevron Nozzle Uniquely Tailored for Propulsion Airframe Aeroacoustics
NASA Technical Reports Server (NTRS)
Massey, Steven J.; Elmiligui, Alaa A.; Hunter, Craig A.; Thomas, Russell H.; Pao, S. Paul; Mengle, Vinod G.
2006-01-01
A computational flow field and predicted jet noise source analysis is presented for asymmetrical fan chevrons on a modern separate flow nozzle at take off conditions. The propulsion airframe aeroacoustic asymmetric fan nozzle is designed with an azimuthally varying chevron pattern with longer chevrons close to the pylon. A baseline round nozzle without chevrons and a reference nozzle with azimuthally uniform chevrons are also studied. The intent of the asymmetric fan chevron nozzle was to improve the noise reduction potential by creating a favorable propulsion airframe aeroacoustic interaction effect between the pylon and chevron nozzle. This favorable interaction and improved noise reduction was observed in model scale tests and flight test data and has been reported in other studies. The goal of this study was to identify the fundamental flow and noise source mechanisms. The flow simulation uses the asymptotically steady, compressible Reynolds averaged Navier-Stokes equations on a structured grid. Flow computations are performed using the parallel, multi-block, structured grid code PAB3D. Local noise sources were mapped and integrated computationally using the Jet3D code based upon the Lighthill Acoustic Analogy with anisotropic Reynolds stress modeling. In this study, trends of noise reduction were correctly predicted. Jet3D was also utilized to produce noise source maps that were then correlated to local flow features. The flow studies show that asymmetry of the longer fan chevrons near the pylon work to reduce the strength of the secondary flow induced by the pylon itself, such that the asymmetric merging of the fan and core shear layers is significantly delayed. The effect is to reduce the peak turbulence kinetic energy and shift it downstream, reducing overall noise production. This combined flow and noise prediction approach has yielded considerable understanding of the physics of a fan chevron nozzle designed to include propulsion airframe aeroacoustic interaction effects.
Computational Analysis of a Pylon-Chevron Core Nozzle Interaction
NASA Technical Reports Server (NTRS)
Thomas, Russell H.; Kinzie, Kevin W.; Pao, S. Paul
2001-01-01
In typical engine installations, the pylon of an engine creates a flow disturbance that interacts with the engine exhaust flow. This interaction of the pylon with the exhaust flow from a dual stream nozzle was studied computationally. The dual stream nozzle simulates an engine with a bypass ratio of five. A total of five configurations were simulated all at the take-off operating point. All computations were performed using the structured PAB3D code which solves the steady, compressible, Reynolds-averaged Navier-Stokes equations. These configurations included a core nozzle with eight chevron noise reduction devices built into the nozzle trailing edge. Baseline cases had no chevron devices and were run with a pylon and without a pylon. Cases with the chevron were also studied with and without the pylon. Another case was run with the chevron rotated relative to the pylon. The fan nozzle did not have chevron devices attached. Solutions showed that the effect of the pylon is to distort the round Jet plume and to destroy the symmetrical lobed pattern created by the core chevrons. Several overall flow field quantities were calculated that might be used in extensions of this work to find flow field parameters that correlate with changes in noise.
Correlation of Postoperative Position of the Sesamoids After Chevron Osteotomy With Outcome.
Shi, Glenn G; Henning, Peter; Marks, Richard M
2016-03-01
Postoperative incomplete reduction of the sesamoids has been identified as a potential risk factor for hallux valgus recurrence after proximal osteotomy. However, it is not known whether the postoperative sesamoid position is a risk factor in hallux valgus correction via distal chevron osteotomy with or without dorsal webspace release (DWSR). In this retrospective study, 169 patients who underwent distal chevron osteotomy with or without DWSR were reviewed. Preoperative and postoperative (6 weeks, 6 months, 12 months) weightbearing radiographs were evaluated. Functional hallux valgus angle (HVA), intermetatarsal angle (IMA), and the position of the tibial sesamoid were graded using the center of head method. Seventy-six radiographs were available for review at the 12-month follow-up. Of these, 41 patients underwent DWSR procedure and 35 did not. In both groups, correction of all 3 parameters (HVA, IMA, tibial sesamoid position) were significant at the 12-month follow-up. Comparison of the postoperative results of the 2 groups showed no statistically significant differences. Four feet demonstrated displaced sesamoid position at the 12-month follow-up, with radiographic evidence of recurrence in just one. No significant relationship was found between postoperative sesamoid position and hallux valgus recurrence that occurred in 4 feet. Combining DWSR with a distal chevron osteotomy did not delay healing or increase risk of avascular necrosis, but it did not significantly improve angular measurements or sesamoid position. The concept that postoperative sesamoid position can be used to predict hallux valgus recurrence was not supported by our results when looking at distal chevron correction. Level III, retrospective comparative study. © The Author(s) 2015.
NASA Technical Reports Server (NTRS)
Mengle, Vinod G.; Elkroby, Ronen; Brunsniak, Leon; Thomas, Russ H.
2006-01-01
The flow/acoustic environment surrounding an engine nozzle installed on an airplane, say, under the wing, is asymmetric due to the pylon, the wing and the interaction of the exhaust jet with flaps on the wing. However, the conventional chevrons, which are azimuthally uniform serrations on the nozzle lip, do not exploit the asymmetry due to these propulsion airframe aeroacoustic interactions to reduce jet noise. In this pioneering study we use this non-axisymmetry to our advantage and examine if the total jet-related noise radiated to the ground can be reduced by using different types of azimuthally varying chevrons (AVC) which vary the mixing around the nozzle periphery. Several scale models of the isolated nozzle, representative of high bypass ratio engine nozzles, were made with a pylon and azimuthally varying chevrons on both fan and core nozzles to enhance mixing at the top (near the pylon) with less mixing at the bottom (away from the pylon) or vice versa. Various combinations of fan and core AVC nozzles were systematically tested at typical take-off conditions inside a free jet wind-tunnel and, here, in Part 1 we analyze the acoustics results for the isolated nozzle with a pylon, with installation effects reported in Parts 2 and 3. Several interesting results are discovered: amongst the fan AVCs the top-enhanced mixing T-fan chevron nozzle is quieter in combination with any core AVC nozzle when compared to conventional chevrons; however, the bottom-mixing B-fan chevrons, as well as the core AVC nozzles, by themselves, are noisier. Further, the low-frequency source strengths in the jet plume, obtained via phased microphone arrays, also corroborate the far field sound, and for the T-fan chevrons such sources move further downstream than those for baseline or conventional chevron nozzles.
Numerical Prediction of Chevron Nozzle Noise Reduction using Wind-MGBK Methodology
NASA Technical Reports Server (NTRS)
Engblom, W.A.; Bridges, J.; Khavarant, A.
2005-01-01
Numerical predictions for single-stream chevron nozzle flow performance and farfield noise production are presented. Reynolds Averaged Navier Stokes (RANS) solutions, produced via the WIND flow solver, are provided as input to the MGBK code for prediction of farfield noise distributions. This methodology is applied to a set of sensitivity cases involving varying degrees of chevron inward bend angle relative to the core flow, for both cold and hot exhaust conditions. The sensitivity study results illustrate the effect of increased chevron bend angle and exhaust temperature on enhancement of fine-scale mixing, initiation of core breakdown, nozzle performance, and noise reduction. Direct comparisons with experimental data, including stagnation pressure and temperature rake data, PIV turbulent kinetic energy fields, and 90 degree observer farfield microphone data are provided. Although some deficiencies in the numerical predictions are evident, the correct farfield noise spectra trends are captured by the WIND-MGBK method, including the noise reduction benefit of chevrons. Implications of these results to future chevron design efforts are addressed.
No midterm benefit from low intensity pulsed ultrasound after chevron osteotomy for hallux valgus.
Zacherl, Max; Gruber, Gerald; Radl, Roman; Rehak, Peter H; Windhager, Reinhard
2009-08-01
Chevron osteotomy is a widely accepted method for correction of symptomatic hallux valgus deformity. Full weight bearing in regular shoes is not recommended before 6 weeks after surgery. Low intensity pulsed ultrasound is known to stimulate bone formation leading to more stable callus and faster bony fusion. We performed a randomized, placebo-controlled, double-blinded study on 44 participants (52 feet) who underwent chevron osteotomy to evaluate the influence of daily transcutaneous low intensity pulsed ultrasound (LIPUS) treatment at the site of osteotomy. Follow-up at 6 weeks and 1 year included plain dorsoplantar radiographs, hallux-metatarsophalangeal-interphalangeal scale and a questionnaire on patient satisfaction. There was no statistical difference in any pre- or postoperative clinical features, patient satisfaction or radiographic measurements (hallux valgus angle, intermetatarsal angle, sesamoid index and metatarsal index) except for the first distal metatarsal articular angle (DMAA). The DMAA showed statistically significant (p = 0.046) relapse in the placebo group upon comparison of intraoperative radiographs after correction and fixation (5.2 degrees) and at the 6-week follow-up (10.6 degrees). Despite potential impact of LIPUS on bone formation, we found no evidence of an influence on outcome 6 weeks and 1 year after chevron osteotomy for correction of hallux valgus deformity.
Hazardous Waste Cleanup: Chevron Incorporated-NWPMG00037 Bacon Site in Glenham, New York
Chevron, Inc., former Texaco Research Center, also known as Texaco or Chevron Texaco, operated a Research Center in Glenham, New York from 1931 until its closure in 2003. The Main Facility includes all of the developed areas located north of Fishkill Creek
Evaluation of chevron patterns for use on traffic control devices in street and highway work zones.
DOT National Transportation Integrated Search
1980-01-01
The chevron pattern consists of alternate orange and white stripes that form an arrow pointing in the direction in which traffic is being diverted. The objectives of this research were (1) to select the most effective design for the chevron pattern, ...
Impact of Fluidic Chevrons on Supersonic Jet Noise
NASA Technical Reports Server (NTRS)
Henderson, Brenda; Norum, Thomas
2007-01-01
The impact of fluidic chevrons on broadband shock noise and mixing noise for single stream and coannular jets was investigated. Air was injected into the core flow of a bypass ratio 5 nozzle system using a core fluidic chevron nozzle. For the single stream experiments, the fan stream was operated at the wind tunnel conditions and the core stream was operated at supersonic speeds. For the dual stream experiments, the fan stream was operated at supersonic speeds and the core stream was varied between subsonic and supersonic conditions. For the single stream jet at nozzle pressure ratio (NPR) below 2.0, increasing the injection pressure of the fluidic chevron increased high frequency noise at observation angles upstream of the nozzle exit and decreased mixing noise near the peak jet noise angle. When the NPR increased to a point where broadband shock noise dominated the acoustic spectra at upstream observation angles, the fluidic chevrons significantly decreased this noise. For dual stream jets, the fluidic chevrons reduced broadband shock noise levels when the fan NPR was below 2.3, but had little or no impact on shock noise with further increases in fan pressure. For all fan stream conditions investigated, the fluidic chevron became more effective at reducing mixing noise near the peak jet noise angle as the core pressure increased.
Wu, Yiping; Zhao, Xiaohua; Chen, Chen; He, Jiayuan; Rong, Jian; Ma, Jianming
2016-10-01
In China, the Chevron alignment sign on highways is a vertical rectangle with a white arrow and border on a blue background, which differs from its counterpart in other countries. Moreover, little research has been devoted to the effectiveness of China's Chevron signs; there is still no practical method to quantitatively describe the impact of Chevron signs on driver performance in roadway curves. In this paper, a driving simulator experiment collected data on the driving performance of 30 young male drivers as they navigated on 29 different horizontal curves under different conditions (presence of Chevron signs, curve radius and curve direction). To address the heterogeneity issue in the data, three models were estimated and tested: a pooled data linear regression model, a fixed effects model, and a random effects model. According to the Hausman Test and Akaike Information Criterion (AIC), the random effects model offers the best fit. The current study explores the relationship between driver performance (i.e., vehicle speed and lane position) and horizontal curves with respect to the horizontal curvature, presence of Chevron signs, and curve direction. This study lays a foundation for developing procedures and guidelines that would allow more uniform and efficient deployment of Chevron signs on China's highways. Copyright © 2016 Elsevier Ltd. All rights reserved.
Erickson, Gregory M; Kristopher Lappin, A; Larson, Peter
2005-01-01
The sex of non-avian dinosaurs has been inferred on numerous occasions using a variety of anatomical criteria, but the efficacy of none has been proven. Nearly 50 years ago Romer suggested that the cranial-most or first chevron in the tails of some reptiles, including crocodilians, is sexually dimorphic. Recent work on this subject purportedly substantiated that the female first chevron articulates in a more caudal position than in males. Furthermore, it was concluded that this element is shorter in females. These phenotypic attributes theoretically provide a broader cloacal passageway for eggs by ovipositing females and a greater attachment area for male "penile retractor muscles". Because theropod dinosaurs such as Tyrannosaurus rex presumably show similar variation in chevron anatomy, the same criteria has been advocated for sexing dinosaurs. We tested the neontological model for the chevron sexual dimorphism hypothesis using a skeletonized growth series of American alligators (Alligator mississippiensis) of known sex. No statistical support for the hypothesis was found. Furthermore, analysis of a diversity of crocodilian taxa from museum collections revealed similar findings suggesting the alligator results are not taxon specific. Study of well-preserved tyrannosaurid dinosaurs in museum collections showed nearly invariant chevron positioning like that seen in crocodilians. This suggests the usefulness of chevron anatomy for sexing dinosaurs is tenuous.
NASA Astrophysics Data System (ADS)
Hartl, Darren J.; Lagoudas, Dimitris C.
2007-04-01
This work describes the thermomechanical characterization and FEA modeling of commercial jet engine chevrons incorporating active Shape Memory Alloy (SMA) beam components. The reduction of community noise at airports generated during aircraft take-off has become a major research goal. Serrated aerodynamic devices along the trailing edge of a jet engine primary and secondary exhaust nozzle, known as chevrons, have been shown to greatly reduce jet noise by encouraging advantageous mixing of the streams. To achieve the noise reduction, the secondary exhaust nozzle chevrons are typically immersed into the fan flow which results in drag, or thrust losses during cruise. SMA materials have been applied to this problem of jet engine noise. Active chevrons, utilizing SMA components, have been developed and tested to create maximum deflection during takeoff and landing while minimizing deflection into the flow during the remainder of flight, increasing efficiency. Boeing has flight tested one Variable Geometry Chevron (VGC) system which includes active SMA beams encased in a composite structure with a complex 3-D configuration. The SMA beams, when activated, induce the necessary bending forces on the chevron structure to deflect it into the fan flow and reduce noise. The SMA composition chosen for the fabrication of these beams is a Ni60Ti40 (wt%) alloy. In order to calibrate the material parameters of the constitutive SMA model, various thermomechanical experiments are performed on trained (stabilized) standard SMA tensile specimens. Primary among these tests are thermal cycles at various constant stress levels. Material properties for the shape memory alloy components are derived from this tensile experimentation. Using this data, a 3-D FEA implementation of a phenomenological SMA model is calibrated and used to analyze the response of the chevron. The primary focus of this work is the full 3-D modeling of the active chevron system behavior by considering the SMA beams as fastened to the elastic chevron structure. Experimental and numerical results are compared. Discussion is focused on actuation properties such as tip deflection and chevron bending profile. The model proves to be an accurate tool for predicting the mechanical response of such a system subject to defined thermal inputs.
76 FR 63294 - Chevron Products Company v. SFPP, L.P. ; Notice of Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. OR12-1-000; Docket No. IS11-585-000] Chevron Products Company v. SFPP, L.P. ; Notice of Complaint Take notice that on October 5.... 13(1), Chevron Products Company (Complainants) filed a complaint against SFPP, L.P. (Respondent...
NASA Astrophysics Data System (ADS)
Kosulya, A. V.; Verbitskii, V. G.
2017-09-01
The dependence of the transverse section of an electron beam on the distance between plates and on the accelerating potential difference is determined for a chevron unit of a microelectronic position-sensitive detector (MPSD) with two microchannel plates. The geometry of the MPSD chevron unit is designed and optimized.
Chevron nails: a normal variant in the pediatric population.
Delano, Sofia; Belazarian, Leah
2014-01-01
A 7-month-old girl was evaluated for V-shaped ridging of the fingernails consistent with chevron nails. Chevron nails are a normal variant in the pediatric population that is frequently outgrown. This case nicely demonstrates this normal finding that has so rarely been reported in the literature. © 2013 Wiley Periodicals, Inc.
The Chevron Refinery is an active, 339-acre facility located in a heavily industrial area on the east side the city of Perth Amboy, Middlesex County, New Jersey. The facility was built by the Barber Asphalt Company in 1920, who operated it as an asphalt
Wagener, Marc L; Dezillie, Marleen; Hoendervangers, Yvette; Eygendaal, Denise
2015-04-01
Exposure of the distal humerus in case of an articular fracture is often performed through a Chevron osteotomy of the olecranon. Several options have been described for re-fixation of the Chevron osteotomy. Pull-out of the hard-wear is often seen as complication. In this study, an evaluation of the re-fixation of the Chevron osteotomy through a cancellous screw and suture tension band was performed. The data of 19 patients in whom a Chevron osteotomy was re-fixated with a cancellous screw in combination with a suture tension band were used. Evaluation was performed by assessment of the post-operative X-rays and documentation of complications. In all 19 cases, evaluation of the post-operative X-rays showed complete consolidation without dislocation or other complications. Re-fixation of a Chevron osteotomy of the olecranon with a large cancellous screw with a suture tension band provides adequate stability to result in proper healing of the osteotomy in primary cases when early post-operative mobilisation is allowed. Complications as pull-out of the hard-wear were not reported.
Electro-optic response in thin smectic C* film with chevron structures
NASA Astrophysics Data System (ADS)
Kudreyko, Aleksey A.; Migranov, Nail G.; Migranova, Dana N.
2016-12-01
The effects in electrostatic models of chevron surface-stabilized ferroelectric liquid crystals are investigated through numerical modeling. To study smectic C* director distribution within the cell, we consider two nonlinear approaches: the chevron interface does not interplay with the electric field; the electric field interplays with the chevron interface. The obtained results of the director field distribution are compared with the earlier linearized studies. We find that whether or not the electric field interplays with the chevron interface, the electro-optic response requires a generalized approach for its description. The threshold electric field, which is necessary for switching between two stable director states in the chevron cell is evaluated. This study suggests that, in many cases of practical interest, electro-optic response to the electric field and the threshold electric field can be precisely estimated. We argue that, beside being numerically efficient, our approach provides a convenient and a novel standpoint for looking at the electro-optic response problem. Project supported by the Russian Foundation for Basic Research (RFBR) (Grant Nos. 16-32-00043 and 14-02-97026).
Trailing edge cooling using angled impingement on surface enhanced with cast chevron arrangements
Lee, Ching-Pang; Heneveld, Benjamin E.; Brown, Glenn E.; Klinger, Jill
2015-05-26
A gas turbine engine component, including: a pressure side (12) having an interior surface (34); a suction side (14) having an interior surface (36); a trailing edge portion (30); and a plurality of suction side and pressure side impingement orifices (24) disposed in the trailing edge portion (30). Each suction side impingement orifice is configured to direct an impingement jet (48) at an acute angle (52) onto a target area (60) that encompasses a tip (140) of a chevron (122) within a chevron arrangement (120) formed in the suction side interior surface. Each pressure side impingement orifice is configured to direct an impingement jet at an acute angle onto an elongated target area that encompasses a tip of a chevron within a chevron arrangement formed in the pressure side interior surface.
Solution-Synthesized Chevron Graphene Nanoribbons Exfoliated onto H:Si(100).
Radocea, Adrian; Sun, Tao; Vo, Timothy H; Sinitskii, Alexander; Aluru, Narayana R; Lyding, Joseph W
2017-01-11
There has been tremendous progress in designing and synthesizing graphene nanoribbons (GNRs). The ability to control the width, edge structure, and dopant level with atomic precision has created a large class of accessible electronic landscapes for use in logic applications. One of the major limitations preventing the realization of GNR devices is the difficulty of transferring GNRs onto nonmetallic substrates. In this work, we developed a new approach for clean deposition of solution-synthesized atomically precise chevron GNRs onto H:Si(100) under ultrahigh vacuum. A clean transfer allowed ultrahigh-vacuum scanning tunneling microscopy (STM) to provide high-resolution imaging and spectroscopy and reveal details of the electronic structure of chevron nanoribbons that have not been previously reported. We also demonstrate STM nanomanipulation of GNRs, characterization of multilayer GNR cross-junctions, and STM nanolithography for local depassivation of H:Si(100), which allowed us to probe GNR-Si interactions and revealed a semiconducting-to-metallic transition. The results of STM measurements were shown to be in good agreement with first-principles computational modeling.
Seo, Jeong-Ho; Boedijono, Dimas
2016-01-01
Purpose The aim of this study was to investigate new point-connecting measurements for the hallux valgus angle (HVA) and the first intermetatarsal angle (IMA), which can reflect the degree of subluxation of the first metatarsophalangeal joint (MTPJ). Also, this study attempted to compare the validity of midline measurements and the new point-connecting measurements for the determination of HVA and IMA values. Materials and Methods Sixty feet of hallux valgus patients who underwent surgery between 2007 and 2011 were classified in terms of the severity of HVA, congruency of the first MTPJ, and type of chevron metatarsal osteotomy. On weight-bearing dorsal-plantar radiographs, HVA and IMA values were measured and compared preoperatively and postoperatively using both the conventional and new methods. Results Compared with midline measurements, point-connecting measurements showed higher inter- and intra-observer reliability for preoperative HVA/IMA and similar or higher inter- and intra-observer reliability for postoperative HVA/IMA. Patients who underwent distal chevron metatarsal osteotomy (DCMO) had higher intraclass correlation coefficient for inter- and intra-observer reliability for pre- and post-operative HVA and IMA measured by the point-connecting method compared with the midline method. All differences in the preoperative HVAs and IMAs determined by both the midline method and point-connecting methods were significant between the deviated group and subluxated groups (p=0.001). Conclusion The point-connecting method for measuring HVA and IMA in the subluxated first MTPJ may better reflect the severity of a HV deformity with higher reliability than the midline method, and is more useful in patients with DCMO than in patients with proximal chevron metatarsal osteotomy. PMID:26996576
Electrothermal Microactuators With Peg Drive Improve Performance for Brain Implant Applications
Anand, Sindhu; Sutanto, Jemmy; Baker, Michael S.; Okandan, Murat; Muthuswamy, Jit
2013-01-01
This paper presents a new actuation scheme for in-plane bidirectional translation of polysilicon microelectrodes. The new Chevron-peg actuation scheme uses microelectromechanical systems (MEMS) based electrothermal microactuators to move microelectrodes for brain implant applications. The design changes were motivated by specific needs identified by the in vivo testing of an earlier generation of MEMS microelectrodes that were actuated by the Chevron-latch type of mechanism. The microelectrodes actuated by the Chevron-peg mechanism discussed here show improved performance in the following key areas: higher force generation capability (111 μN per heat strip compared to 50 μN), reduced power consumption (91 mW compared to 360 mW), and reliable performance with consistent forward and backward movements of microelectrodes. Failure analysis of the Chevron-latch and the Chevron-peg type of actuation schemes showed that the latter is more robust to wear over four million cycles of operation. The parameters for the activation waveforms for Chevron-peg actuators were optimized using statistical analysis. Waveforms with a 1-ms time period and a 1-Hz frequency of operation showed minimal error between the expected and the actual movement of the microelectrodes. The new generation of Chevron-peg actuators and microelectrodes are therefore expected to enhance the longevity and performance of implanted microelectrodes in the brain. [2011-0341] PMID:24431926
76 FR 35880 - Chevron Products Company v. SFPP, L.P.; Notice of Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. OR11-16-000] Chevron Products Company v. SFPP, L.P.; Notice of Complaint Take notice that on June 13, 2011, pursuant to 13(1) of... Proceedings, 18 CFR 343.1(a), Chevron Products Company (Complaint) filed a formal complaint challenging the...
76 FR 35881 - Chevron Products Company v. SFPP, L.P.; Notice of Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. OR11-15-000] Chevron Products Company v. SFPP, L.P.; Notice of Complaint Take notice that on June 13, 2011, pursuant to 13(1) of... Proceedings, 18 CFR 343.1(a), Chevron Products Company (Complainant) filed a formal complaint against SFPP, L...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-15
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. OR13-26-000] Notice of Complaint; Chevron Products Company v. Enterprise TE Products Pipeline Company, LLC Take notice that on July... Procedural Rules Applicable to Oil Pipeline Proceedings, 18 CFR 343.1(a) and 343.2(c), Chevron Products...
NASA Astrophysics Data System (ADS)
Kosulya, A. V.; Verbitskii, V. G.
2017-11-01
A mathematical model of the response of a microchannel multiplier based on two microchannel plates in the chevron assembly has been considered. Analytical expressions relating the parameters of input and output signals have been obtained. The geometry of the chevron unit has been determined, and it has been optimized.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... (EIS) for the Chevron Energy Solutions/Solar Millennium (CESSM), LLC's Blythe Solar Power Plant (BSPP... project and amend the CDCA Plan to prohibit solar energy projects on the project site. The BLM will take..., LVRWB09B2600] Notice of Availability of the Final Environmental Impact Statement for the Chevron Energy...
Impact of New Chevron Configurations on Mixing Enhancement in Subsonic Jets
NASA Astrophysics Data System (ADS)
Mullick, Sunayan
A major contributor to the overall noise of an aircraft is jet noise - the noise generated by the gases exiting the exhaust nozzle of a jet engine. One approach to mitigate jet noise is through the implementation of chevron nozzles. In the present context, first, a baseline axisymmetric separate-flow nozzle, termed the 3BB model, with an external plug having a bypass ratio of 5 is analyzed. The specifications of this nozzle are taken from an acoustic study carried out at the NASA John H. Glenn Research Center. Then, various chevron configurations are added to the core and fan nozzles to produce three chevron nozzles. Of these, two are presented as modified versions of the conventional chevron nozzle and form the essence of this work. The third chevron nozzle represents the conventional chevron nozzle in use today. For all the nozzles considered in this study, the flow conditions used represent the takeoff environment of a contemporary subsonic aircraft. The fan nozzle total pressure is set to 1.8 atm while the core nozzle total pressure is 1.65 atm. The total temperature inside the fan nozzle is set to 333.3 K while the core nozzle has a total temperature of 833.3 K. The freestream conditions are given as: static pressure = 0.98 atm, total pressure = 1.04 atm, total temperature = 298.8 K and Mach number = 0.28. For the three chevron nozzles, the core and fan nozzles have 12 chevrons each. Each chevron extends over a sector of 30 degrees of the circumference. To carry out the study presented herein, first, computer-aided design (CAD) models of the four nozzles are created. These models are then used to carry out computational fluid dynamics (CFD) simulations with the conditions stated above. The CFD simulations are performed on STAR-CCM+. The results of the simulations carried out for the baseline nozzle are compared with existing experimental and numerical data to validate the use of STAR-CCM+ as a tool for studying jet flows. Once this step is complete, numerical simulations are carried out for the three chevron nozzles. The results from these are compared with those obtained for the baseline nozzle. The turbulent kinetic energy (TKE) and the mean axial velocity are the two main parameters that represent mixing enhancement and are focused on in this work. Since the TKE levels for a given nozzle are directly linked to the jet noise generated, the TKE is an important indication of the jet noise produced by a given nozzle. Other jet mixing parameters such as the centerline total temperature decay and the centerline velocity of the jet flow exiting each nozzle are also analyzed. A 2-D axisymmetric grid is produced for the 3BB nozzle while a 3-D mesh is generated for each of the chevron nozzles. To reduce the computation cost, only a 30° sector of the chevron nozzles is modeled. Since the Shear Stress Transport (SST) k-o turbulence model has been widely used in several aerospace applications, it is chosen for all simulations here as well. The numerical analysis shows that STAR-CCM+ can successfully be used for the study of jet flows. Although some shortcomings do exist, the simulations provide a reasonable understanding of jet flows. Of the three chevron nozzles studied, the simulations demonstrate that in comparison to the baseline nozzle, all three chevron nozzles register peak values of the turbulent kinetic energy that are lower than that observed for the 3BB nozzle. The regions of highest turbulence also appear further upstream for the chevron nozzles. Compared to the conventional chevron nozzle, the two parametric designs presented in this work show a potential reduction in the peak values of the turbulent kinetic energy in their respective flows. A slight reduction in the mean axial velocities is also observed for these nozzles. Further, a close inspection of the turbulent flowfield of one of the parametric designs shows that the highest intensity turbulence in the flow is first observed at the most upstream location for this nozzle. The high levels of TKE are also confined to a smaller region in this case. Based on these results, the two parametric chevron nozzle designs demonstrate a potential to produce lower jet noise than what is observed in case of a conventional chevron nozzle. Finally, a study of the turbulent flowfields of all the nozzles shows that the mixing between the fan and freestream shear layers still dominates the mixing in the jet flow. However, the chevrons are able to add streamwise vortices to the flow that enhance mixing between the core and fan shear layers to some extent. This promotes better mixing and as a result, the turbulence in the jet plume is reduced.
Sharma, Krishn M; Parks, Brent G; Nguyen, Augustine; Schon, Lew C
2005-10-01
A change in screw orientation in fixing the chevron proximal first metatarsal osteotomy was noted anecdotally to improve fixation strength. The authors hypothesized that plantar-to-dorsal screw orientation would be more stable than the conventional dorsal-to-plantar screw orientation for fixation of the chevron osteotomy. The purpose of this study was to determine if the load-to-failure and stiffness of the chevron type proximal first metatarsal osteotomy stabilized using plantar-to-dorsal screw fixation were greater than with the more conventional dorsal-to-plantar screw fixation method. One foot from each of eight matched cadaver pairs was randomly assigned to one of two groups: 1) fixation with a dorsal-to-plantar lag screw or 2) fixation with a plantar-to-dorsal lag screw. A proximal chevron osteotomy was then created using standard technique and the metatarsal was fixed according to previously established method. The bone was potted in polyester resin, and the construct was fitted into a materials testing system machine in which load was applied to the plantar aspect of the metatarsal until failure. The two groups were compared using a two-tailed Student t test. The average load-to-failure and stiffness of the chevron osteotomy fixed with the plantar-to-dorsal lag screw were significantly greater (p < 0.05) than the group fixed with more conventional dorsal-to-plantar lag screws. Plantar-to-dorsal screw orientation was more stable than the conventional dorsal-to-plantar screw orientation for fixation of the proximal chevron osteotomy. Plantar-to-dorsal screw orientation should be considered when using the chevron proximal first metatarsal osteotomy.
Comparison of Chevron and Distal Oblique Osteotomy for Bunion Correction.
Scharer, Brandon M; DeVries, J George
2016-01-01
The chevron osteotomy is a standard procedure by which bunions are corrected. One of us routinely performs a distal oblique osteotomy, which, to the best of our knowledge, has not been described for the correction of bunion deformities. The purpose of the present study was to compare the short- and medium-term results of the distal oblique and chevron osteotomies for bunion correction. We performed a retrospective clinical and radiographic comparison of patients who had undergone a distal oblique or chevron osteotomy for the correction of bunion deformity. In addition, a prospective patient satisfaction survey was undertaken. A total of 55 patients were included in the present study and were treated from January 2012 to November 2014. Of the 55 patients, 27 (49.2%) were in the chevron group and 28 (50.8%) in the distal oblique group. Radiographically, no statistically significant difference was found between the 2 groups with respect to postoperative first intermetatarsal angle (p < .0001) and hallux valgus angle (p < .0001), but a greater change was found in the intermetatarsal angle in the distal oblique group (p = .467). Prospective patient satisfaction scores were available for 33 patients (60%), 16 (29%) in the chevron group and 17 (31%) in the distal oblique group. When converting the satisfaction score to a numerical score, the chevron group scored 3.3 ± 1.1 and the distal oblique group scored 3.2 ± 0.8 (p = .812). We found that the distal oblique osteotomy used in the present study is simple and reliable and showed radiographic correction and patient satisfaction equivalent to those in the chevron osteotomy. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Design and fabrication of a MEMS chevron-type thermal actuator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baracu, Angela, E-mail: angela.baracu@imt.ro; Voicu, Rodica; Müller, Raluca
This paper presents the design and fabrication of a MEMS chevron-type thermal actuator. The device was designed for fabrication in the standard MEMS technology, where the topography of the upper layers depends on the patterns of structural and sacrificial layers underneath. The proposed actuator presents some advantages over usual thermal vertical chevron actuators by means of low operating voltages, high output force and linear movement without deformation of the shaft. The device simulations were done using COVENTOR software. The movement obtained by simulation was 12 μm, for a voltage of 0.2 V and the current intensity of 257 mA. Themore » design optimizes the in-plane displacement by fixed anchors and beam inclination angle. Heating is provided by Joule dissipation. The material used for manufacture of chevron-based actuator was aluminum due to its thermal and mechanical properties. The release of the movable part was performed using isotropic dry etching by Reactive Ion Etching (RIE). A first inspection was achieved using Scanning Electron Microscope (SEM). In order to obtain the in-plane displacement we carried out electrical measurements. The thermal actuator can be used for a variety of optical and microassembling applications. This kind of thermal actuator could be integrated easily with other micro devices since its fabrication is compatible with the general semiconductor processes.« less
Shariff, Raheel; Attar, Fahad; Osarumwene, Donald; Siddique, Rehan; Attar, Gulam Dastagir
2009-04-01
Controversy exists with regard to the effects of chevron osteotomy on blood supply and subsequent development of avascular necrosis (AVN) of the first metatarsal head. The aim of this study was to assess the incidence of avascular necrosis in our centre following chevron osteotomy for hallux valgus, using bone scintigraphy. Thirty nine patients who had a chevron osteotomy for treatment of hallux valgus were prospectively studied. Mean follow-up was 14 months. Bone scintigraphy was used to assess metatarsal head perfusion at an average 8.5 weeks post operatively. Three patients (7.7%) showed abnormal bone scan around the metatarsal head. Further evaluation of these patients did not show any sign of AVN. We conclude there appears to be a risk of circulatory disturbance to the metatarsal head following chevron osteotomy of the first metarsal (7.7% in this study); however this does not translate into clinically significant AVN.
Active Noise Control of Radiated Noise from Jets Originating NASA
NASA Technical Reports Server (NTRS)
Doty, Michael J.; Fuller, Christopher R.; Schiller, Noah H.; Turner, Travis L.
2013-01-01
The reduction of jet noise using a closed-loop active noise control system with highbandwidth active chevrons was investigated. The high frequency energy introduced by piezoelectrically-driven chevrons was demonstrated to achieve a broadband reduction of jet noise, presumably due to the suppression of large-scale turbulence. For a nozzle with one active chevron, benefits of up to 0.8 dB overall sound pressure level (OASPL) were observed compared to a static chevron nozzle near the maximum noise emission angle, and benefits of up to 1.9 dB OASPL were observed compared to a baseline nozzle with no chevrons. The closed-loop actuation system was able to effectively reduce noise at select frequencies by 1-3 dB. However, integrated OASPL did not indicate further reduction beyond the open-loop benefits, most likely due to the preliminary controller design, which was focused on narrowband performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, M.G.
1995-12-31
The quasi-static fracture behavior of advanced ceramics was assessed in the temperature range of 20{degrees} to 1400{degrees}C. Chevron-notched, three-point flexure specimens and a laser-based CMOD measurement systems were used in testing. Types of materials characterized included monolithic ceramics (SiC, Si{sub 3}N{sub 4}, MgAl{sub 2}O{sub 4}), self-reinforced monoliths (acicular-grained Si{sub 3}N{sub 4}, acicular grained mullite), and ceramic matrix composites (SiC whisker/Al{sub 2}O{sub 3} matrix, TiB{sub 2} particulate/SiC matrix, SiC fibre/CVI SiC matrix, Al{sub 2}O{sub 3} fibre/CVI SiC matrix). Fracture resistance behaviour of the materials was quantified as three distinct regimes of the fracture histories. At crack initiation, the apparent fracture toughnessmore » was evaluated as the critical stress intensity factor, K{sub IC}. During stable crack propagation, the crack growth resistance was characterized by the instantaneous strain energy release rate, G{sub R} using a compliance method assuming linear-elastic unloading to calculate the effective crack lengths. At final fracture, the complete fracture process was quantified using the work-of-fracture, WOF, which can be equated to the fracture surface energy for linearelastic materials. Results indicate that the chevron-notched, three-point flexure specimen facilitates the study of fracture behavior in a wide range of brittle and quasi-brittle materials at elevated temperatures. The unique features of the chevron geometry, which are automatic, in-situ crack initiation and inherent stable crack growth, are crucial to the successful evaluation of the fracture tests.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-12
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-13-000; PR03-17-000] Chevron Keystone Gas Storage, LLC; Notice of Notification of Change in Market Power Analysis and Request for Renewed Approval of Market-Based Rates April 5, 2010. Take notice that on March 31, 2010, Chevron...
ERIC Educational Resources Information Center
Madfes, Tania J.
In 1986, responding to the nation's teacher shortage, especially in the fields of mathematics and science, Chevron USA funded the ENCORE Program to facilitate the entrance of nontraditional recruits into the profession with alternative credentialing. Chevron also funded this study of mid-life career change to teaching in order to enable…
DOT National Transportation Integrated Search
2013-03-01
Current TxDOT practice allows installation of all existing chevron sizes on 7-ft mounting height, but restricts the use of 4-ft mounting height for the three smallest existing chevron signsthat is, 12 inches 18 inches, 18 inches 24 inches, a...
Chevron osteotomy in patients with scheduled osteotomy of the medial malleolus.
Gül, Murat; Yavuz, Umut; Çetinkaya, Engin; Aykut, Ümit Selçuk; Özkul, Barış; Kabukçuoğlu, Yavuz Selim
2015-01-01
The aim of the present study was to evaluate intermediate-term outcomes of Chevron osteotomy for treatment of osteochondral lesions of the talus with mosaicplasty and to assess its effect on surgery and whether it reduces complications that might occur intraoperatively. The present study included a total of 42 patients (31 men, 11 women) who underwent Chevron osteotomy of the medial malleolus and who had been followed for more than 2 years. Mean age of the patients was 34 years (range: 18-54 years). Preoperatively, size of the lesions was measured in millimeters in the coronal and sagittal planes using magnetic resonance imaging (MRI). The angle between the osteotomy with the long axis of the tibia was measured on the coronal plane, the angle between the arms and the angle for the screws to be directed to the osteotomy line were measured on the sagittal plane on the postoperative images. Nonunion, malunion, and complications from the screws were evaluated from X-ray images taken at the final follow-up. Mean duration for follow-up was 31.4 years (range: 24-46). On the X-ray images taken at the final follow-up, no distraction, migration of the distal part, or rotation was observed. Only 1 patient experienced radiological non-union. Mean duration to union was 5.8 weeks (range: 4-14 weeks). Screws of 8 patients were removed at an average of 7.4 months (range: 5-11 months). The angle between the osteotomy line and long axis of the tibia was 29.0°±6.5°, the angel between the osteotomy arms on the sagittal plane was 74.7°±8.3°, and the direction angle of the screws on the coronal plane was 85.7°±5.9°. Chevron osteotomy is an assistive surgical method used for treatment of osteochondral lesions located in the medial talar joint surface (TOL) which provides fast anatomical healing because it allows efficient fixation due to its geometry.
NASA Astrophysics Data System (ADS)
Kılıç, Bayram; İpek, Osman
2017-02-01
In this study, heat transfer rate and effectiveness of corrugated plate heat exchangers having different chevron angles were investigated experimentally. Chevron angles of plate heat exchangers are β = 30° and β = 60°. For this purpose, experimentally heating system used plate heat exchanger was designed and constructed. Thermodynamic analysis of corrugated plate heat exchangers having different chevron angles were carried out. The heat transfer rate and effectiveness values are calculated. The experimental results are shown that heat transfer rate and effectiveness values for β = 60° is higher than that of the other. Obtained experimental results were graphically presented.
Relation between textured surface and diffuse reflectance of Cu films
NASA Astrophysics Data System (ADS)
Shukla, Gaurav; Angappane, S.
2018-04-01
Cu nanostructures namely chevron, slanted and vertical posts deposited on Si substrate by glancing angle deposition (GLAD) technique using DC magnetron sputtering are studied to understand the optical reflectance properties of various textures. The X-ray diffraction analysis confirmed the crystalline nature of the different structures of deposited Cu films. The FESEM images confirmed the formation of chevron, slanted and vertical posts. From the optical reflectance spectra, we found that the reflectance is more for chevron than vertical and slanted posts which have almost the same reflectance over the entire wavelength. The films with chevron texture would find various applications, like, light detector, light trapping, sensors etc.
Street, Timothy O; Barrick, Doug
2009-01-01
The Notch ankyrin domain is a repeat protein whose folding has been characterized through equilibrium and kinetic measurements. In previous work, equilibrium folding free energies of truncated constructs were used to generate an experimentally determined folding energy landscape (Mello and Barrick, Proc Natl Acad Sci USA 2004;101:14102–14107). Here, this folding energy landscape is used to parameterize a kinetic model in which local transition probabilities between partly folded states are based on energy values from the landscape. The landscape-based model correctly predicts highly diverse experimentally determined folding kinetics of the Notch ankyrin domain and sequence variants. These predictions include monophasic folding and biphasic unfolding, curvature in the unfolding limb of the chevron plot, population of a transient unfolding intermediate, relative folding rates of 19 variants spanning three orders of magnitude, and a change in the folding pathway that results from C-terminal stabilization. These findings indicate that the folding pathway(s) of the Notch ankyrin domain are thermodynamically selected: the primary determinants of kinetic behavior can be simply deduced from the local stability of individual repeats. PMID:19177351
Design, fabrication, and testing of a SMA hybrid composite jet engine chevron
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Cabell, Randolph H.; Cano, Roberto J.; Fleming, Gary A.
2006-01-01
Control of jet noise continues to be an important research topic. Exhaust nozzle chevrons have been shown to reduce jet noise, but parametric effects are not well understood. Additionally, thrust loss due to chevrons at cruise suggests significant benefit from deployable chevrons. The focus of this study is development of an active chevron concept for the primary purpose of parametric studies for jet noise reduction in the laboratory and technology development to leverage for full scale systems. The active chevron concept employed in this work consists of a laminated composite structure with embedded shape memory alloy (SMA) actuators, termed a SMA hybrid composite (SMAHC). The actuators are embedded on one side of the middle surface such that thermal excitation generates a moment and deflects the structure. A brief description of the chevron design is given followed by details of the fabrication approach. Results from bench top tests are presented and correlated with numerical predictions from a model for such structures that was recently implemented in MSC.Nastran and ABAQUS. Excellent performance and agreement with predictions is demonstrated. Results from tests in a representative flow environment are also presented. Excellent performance is again achieved for both open- and closed-loop tests, the latter demonstrating control to a specified immersion into the flow. The actuation authority and immersion performance is shown to be relatively insensitive to nozzle pressure ratio (NPR). Very repeatable immersion control with modest power requirements is demonstrated.
Active Chevrons for Jet Noise Reduction
NASA Technical Reports Server (NTRS)
Depuru-Mohan, N. K.; Doty, M. J.
2017-01-01
Jet noise is often a dominant component of aircraft noise, particularly at takeoff. To meet the stringent noise regulations, the aircraft industry is in a pressing need of advanced noise reduction concepts. In the present study, the potential of piezoelectrically-activated chevrons for jet noise reduction was experimentally investigated. The perturbations near the nozzle exit caused by piezoelectrically-activated chevrons could be used to modify the growth rate of the mixing layer and thereby potentially reduce jet noise. These perturbations are believed to increase the production of small-scale disturbances at the expense of large-scale turbulent structures. These large-scale turbulent structures are responsible for the dominant portion of the jet mixing noise, particularly low-frequency noise. Therefore, by exciting the static chevron geometry through piezoelectric actuators, an additional acoustic benefit could possibly be achieved. To aid in the initial implementation of this concept, several flat-faced faceted nozzles (four, six, and eight facets) were investigated. Among the faceted nozzles, it was found that the eight-faceted nozzle behaves very similarly to the round nozzle. Furthermore, among the faceted nozzles with static chevrons, the four-faceted nozzle with static chevrons was found to be most effective in terms of jet noise reduction. The piezoelectrically-activated chevrons reduced jet noise up to 2 dB compared to the same nozzle geometry without excitation. This benefit was observed over a wide range of excitation frequencies by applying very low voltages to the piezoelectric actuators.
Impact of chevron spacing and asymmetric distribution on supersonic jet acoustics and flow
NASA Astrophysics Data System (ADS)
Heeb, N.; Gutmark, E.; Kailasanath, K.
2016-05-01
An experimental investigation into the effect of chevron spacing and distribution on supersonic jets was performed. Cross-stream and streamwise particle imaging velocimetry measurements were used to relate flow field modification to sound field changes measured by far-field microphones in the overexpanded, ideally expanded, and underexpanded regimes. Drastic modification of the jet cross-section was achieved by the investigated configurations, with both elliptic and triangular shapes attained downstream. Consequently, screech was nearly eliminated with reductions in the range of 10-25 dB depending on the operating condition. Analysis of the streamwise velocity indicated that both the mean shock spacing and strength were reduced resulting in an increase in the broadband shock associated noise spectral peak frequency and a reduction in the amplitude, respectively. Maximum broadband shock associated noise amplitude reductions were in the 5-7 dB range. Chevron proximity was found to be the primary driver of peak vorticity production, though persistence followed the opposite trend. The integrated streamwise vorticity modulus was found to be correlated with peak large scale turbulent mixing noise reduction, though optimal overall sound pressure level reductions did not necessarily follow due to the shock/fine scale mixing noise sources. Optimal large scale mixing noise reductions were in the 5-6 dB range.
Jet Noise Shielding Provided by a Hybrid Wing Body Aircraft
NASA Technical Reports Server (NTRS)
Doty, Michael J.; Brooks, Thomas F.; Burley, Casey L.; Bahr, Christopher J.; Pope, Dennis S.
2014-01-01
One approach toward achieving NASA's aggressive N+2 noise goal of 42 EPNdB cumulative margin below Stage 4 is through the use of novel vehicle configurations like the Hybrid Wing Body (HWB). Jet noise measurements from an HWB acoustic test in NASA Langley's 14- by 22-Foot Subsonic Tunnel are described. Two dual-stream, heated Compact Jet Engine Simulator (CJES) units are mounted underneath the inverted HWB model on a traversable support to permit measurement of varying levels of shielding provided by the fuselage. Both an axisymmetric and low noise chevron nozzle set are investigated in the context of shielding. The unshielded chevron nozzle set shows 1 to 2 dB of source noise reduction (relative to the unshielded axisymmetric nozzle set) with some penalties at higher frequencies. Shielding of the axisymmetric nozzles shows up to 6.5 dB of reduction at high frequency. The combination of shielding and low noise chevrons shows benefits beyond the expected additive benefits of the two, up to 10 dB, due to the effective migration of the jet source peak noise location upstream for increased shielding effectiveness. Jet noise source maps from phased array results processed with the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm reinforce these observations.
Smith, Simon E; Landorf, Karl B; Butterworth, Paul A; Menz, Hylton B
2012-01-01
The chevron and scarf osteotomies are commonly used for the surgical management of hallux valgus (HV). However, there is debate as to whether one osteotomy provides more 1-2 intermetatarsal (1-2 IMA) correction than the other. The objective of this systematic review and meta-analysis was to compare the effectiveness of 3 types of first metatarsal osteotomy for reducing the 1-2 IMA in HV correction: the chevron osteotomy, the long plantar arm (modified) chevron osteotomy, and the scarf osteotomy. A systematic search for eligible studies was performed of the following databases: Medline, Embase (Ovid), CINAHL (EBSCO Host), and The Cochrane Database of Systematic Reviews and Cochrane Central Register of Controlled Clinical Trials. Only English-language studies previous to May 2010 were included in the review. Additional hand and electronic content searches of relevant foot and orthopaedic journals were performed. Criteria for inclusion in this analysis included systematic reviews of randomized controlled trials, prospective and retrospective cohort studies, and case-control studies, as well as case-series studies involving the chevron, scarf, or long plantar arm chevron osteotomy of >20 participants with a minimum of 80% follow-up. Quality of evidence of the included studies was assessed with the Grading of Recommendations Assessment, Development and Evaluation system. All pooled analyses were based on a fixed effects model. There was a total of 1351 participants who underwent either a chevron (n = 1028), scarf (n = 300), or long plantar arm chevron osteotomy (n = 23). Only one study for the long plantar arm chevron group fitted the eligibility criteria for this review; however, it was not amenable to meta-analysis. The chevron osteotomy was associated with a mean reduction of 1-2 IMA from preoperative to postoperative of 5.33° (95% confidence interval, 5.12 to 5.54, p < .001), and the scarf osteotomy was associated with a mean reduction of 6.21° (95% confidence interval, 5.70 to 6.72, p < .001). There was a statistically significant 0.88° increase in the correction of the 1-2 IMA in favor of the scarf osteotomy compared with the chevron osteotomy. The studies included in this review were of very low- to low-quality evidence. Our findings indicate that the scarf osteotomy provides greater correction of the 1-2 IMA when used for HV correction. However, only a weak recommendation in favor of the scarf osteotomy can be made based on the low quality of evidence of the studies included in this analysis. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
The chevron osteotomy and avascular necrosis.
Rothwell, Matthew; Pickard, James
2013-03-01
Avascular necrosis (AVN) of the first metatarsal head following the chevron procedure for hallux valgus correction, has been reported widely in the literature; however, in practice it is rarely encountered and may be an over reported myth associated with the chevron technique. Although an infrequent complication, the consequences for those who develop post-operative AVN can be severe. This paper presents an overview of the pathogenesis and classification of AVN. It reviews the vascular anatomy of the first metatarsal with reference to the surgical technique of chevron osteotomy with lateral release. Imaging techniques are described and the management of AVN and revision surgery are also discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
Chevron cutting: Experiment with new runway mixtures
NASA Technical Reports Server (NTRS)
Tyran, K. (Compiler)
1978-01-01
Chevron cutting is shown to occur in different forms depending on the type of tire and the rubber on the running surface. Hardest wear is shown by the main tires of the B-747. Four defects occurred, in the form of two rip separation and two breakouts of the running surface. Tires capped by Thompson are more affected than any of the other rubber-capping fabrics. For Thompson tires, Chevron Cutting is greatly reduced with a fiberglass-rubber mixture. For Goodyear tires, it is eliminated with spiral wrap rubbercapping; resistance to damages through cuts seems to be more positive for Goodyear tires. For Mader tires, the extent of Chevron Cutting is generally smaller than for Thompson cappings.
Intelligent Engine Systems: Acoustics
NASA Technical Reports Server (NTRS)
Wojno, John; Martens, Steve; Simpson, Benjamin
2008-01-01
An extensive study of new fan exhaust nozzle technologies was performed. Three new uniform chevron nozzles were designed, based on extensive CFD analysis. Two new azimuthally varying variants were defined. All five were tested, along with two existing nozzles, on a representative model-scale, medium BPR exhaust nozzle. Substantial acoustic benefits were obtained from the uniform chevron nozzle designs, the best benefit being provided by an existing design. However, one of the azimuthally varying nozzle designs exhibited even better performance than any of the uniform chevron nozzles. In addition to the fan chevron nozzles, a new technology was demonstrated, using devices that enhance mixing when applied to an exhaust nozzle. The acoustic benefits from these devices applied to medium BPR nozzles were similar, and in some cases superior to, those obtained from conventional uniform chevron nozzles. However, none of the low noise technologies provided equivalent acoustic benefits on a model-scale high BPR exhaust nozzle, similar to current large commercial applications. New technologies must be identified to improve the acoustics of state-of-the-art high BPR jet engines.
Chevron closing base wedge bunionectomy.
Bruyn, J M
1993-01-01
The Chevron-base wedge Association for Osteosynthesis fixated bunionectomy provides a stable, aggressive correction of the severe hallux abducto valgus deformity. It is intended for the bunion requiring a double osteotomy in order to adequately reduce both intermetatarsal and proximal articular facet angle with minimal shortening and elevation. This article presents the rationale for the procedure, technique, and a 4-year follow-up of six patients with eight Chevron-base wedge bunionectomies.
Instability waves and low-frequency noise radiation in the subsonic chevron jet
NASA Astrophysics Data System (ADS)
Ran, Lingke; Ye, Chuangchao; Wan, Zhenhua; Yang, Haihua; Sun, Dejun
2017-11-01
Spatial instability waves associated with low-frequency noise radiation at shallow polar angles in the chevron jet are investigated and are compared to the round counterpart. The Reynolds-averaged Navier-Stokes equations are solved to obtain the mean flow fields, which serve as the baseflow for linear stability analysis. The chevron jet has more complicated instability waves than the round jet, where three types of instability modes are identified in the vicinity of the nozzle, corresponding to radial shear, azimuthal shear, and their integrated effect of the baseflow, respectively. The most unstable frequency of all chevron modes and round modes in both jets decrease as the axial location moves downstream. Besides, the azimuthal shear effect related modes are more unstable than radial shear effect related modes at low frequencies. Compared to a round jet, a chevron jet reduces the growth rate of the most unstable modes at downstream locations. Moreover, linearized Euler equations are employed to obtain the beam pattern of pressure generated by spatially evolving instability waves at a dominant low frequency St=0.3 , and the acoustic efficiencies of these linear wavepackets are evaluated for both jets. It is found that the acoustic efficiency of linear wavepacket is able to be reduced greatly in the chevron jet, compared to the round jet.
Instability waves and low-frequency noise radiation in the subsonic chevron jet
NASA Astrophysics Data System (ADS)
Ran, Lingke; Ye, Chuangchao; Wan, Zhenhua; Yang, Haihua; Sun, Dejun
2018-06-01
Spatial instability waves associated with low-frequency noise radiation at shallow polar angles in the chevron jet are investigated and are compared to the round counterpart. The Reynolds-averaged Navier-Stokes equations are solved to obtain the mean flow fields, which serve as the baseflow for linear stability analysis. The chevron jet has more complicated instability waves than the round jet, where three types of instability modes are identified in the vicinity of the nozzle, corresponding to radial shear, azimuthal shear, and their integrated effect of the baseflow, respectively. The most unstable frequency of all chevron modes and round modes in both jets decrease as the axial location moves downstream. Besides, the azimuthal shear effect related modes are more unstable than radial shear effect related modes at low frequencies. Compared to a round jet, a chevron jet reduces the growth rate of the most unstable modes at downstream locations. Moreover, linearized Euler equations are employed to obtain the beam pattern of pressure generated by spatially evolving instability waves at a dominant low frequency St=0.3, and the acoustic efficiencies of these linear wavepackets are evaluated for both jets. It is found that the acoustic efficiency of linear wavepacket is able to be reduced greatly in the chevron jet, compared to the round jet.
Baig, M N; Baig, Usman; Tariq, Ali; Din, Robert
2017-09-20
Introduction Hallux valgus is one of the most common forefoot deformities worldwide. Females are affected more often than males. The three most common clinical symptoms are the painful bunion, transfer metatarsalgia, and hammer or claw toes. Methods This case series consisted of 20 patients who had chevron osteotomy from January 2015 to January 2016. The clinical assessment was measured by The American Orthopedic Foot and Ankle Score (AOFAS), and radiologic assessment was determined by preoperative and postoperative hallux valgus angle (HVA) and intermetatarsal angle (IMA). Results The patients' mean age was 56 years. Out of 20 patients, 19 were female, and one was male. The mean AOFAS improved from 51 preoperatively to 82 postoperatively. The HVA improved from 26° preoperatively to 14°. There were five complications including four Kirschner (K)-wire complications. Conclusion Distal chevron osteotomy is a reliable and time-tested procedure. The K-wire fixation has a relatively high complication rate. We planned to use other methods of fixation and then compared them with K-wires fixation results for future studies.
Baig, Usman; Tariq, Ali; Din, Robert
2017-01-01
Introduction Hallux valgus is one of the most common forefoot deformities worldwide. Females are affected more often than males. The three most common clinical symptoms are the painful bunion, transfer metatarsalgia, and hammer or claw toes. Methods This case series consisted of 20 patients who had chevron osteotomy from January 2015 to January 2016. The clinical assessment was measured by The American Orthopedic Foot and Ankle Score (AOFAS), and radiologic assessment was determined by preoperative and postoperative hallux valgus angle (HVA) and intermetatarsal angle (IMA). Results The patients’ mean age was 56 years. Out of 20 patients, 19 were female, and one was male. The mean AOFAS improved from 51 preoperatively to 82 postoperatively. The HVA improved from 26° preoperatively to 14°. There were five complications including four Kirschner (K)-wire complications. Conclusion Distal chevron osteotomy is a reliable and time-tested procedure. The K-wire fixation has a relatively high complication rate. We planned to use other methods of fixation and then compared them with K-wires fixation results for future studies. PMID:29167752
Lechler, Philipp; Feldmann, Christine; Köck, Franz Xaver; Schaumburger, Jens; Grifka, Joachim; Handel, Martin
2012-01-01
Hallux valgus is a frequent condition of the forefoot, resulting in cosmetic deformity and pain. Chevron osteotomy (CO) is widely employed for the treatment of hallux valgus. Chevron-Akin double osteotomy (CAO) was previously described and superiority over an isolated Chevron procedure was assumed. The objective of this study was to compare the short-to-middle term outcomes of CO and CAO. This study included 72 patients with established diagnosis of mild-to-moderate hallux valgus, treated by either isolated CO or CAO. The CO group included 46 patients (mean 51.5 years) with a mean hallux valgus angle of 27°, while the CAO group included 26 subjects (mean 53.1 years) and a mean hallux valgus angle of 32° preoperatively. All patients were reviewed by physical examination, and standardized questionnaire, and pre- and postoperative standing X-rays were performed. Matched group analysis was carried out to analyze statistical differences of both techniques. The patients were assessed and group matched at a mean of 1.37 years for the CO group and 1.04 years for the CAO group, postoperatively. Mean improvement of HVA (hallux valgus angle) was 10.6° in the CO group and the CAO group improved by 17.5°. DMAA (distal metatarsal articular angle) improved in the CO group by 5.4° and in the CAO by 13.7°. Mean AOFAS score improved by 27.9 (CO) and 21.5 (CAO). Patient satisfaction was high in both groups, with a tendency towards higher values within the CAO group. These findings indicate that Chevron-Akin double osteotomy is a save and practicable procedure for the treatment of mild-to-moderate hallux valgus. Superiority of combined Chevron-Akin procedure over an isolated Chevron osteotomy might be limited to distinct clinical settings, but should not be generally assumed.
NASA Technical Reports Server (NTRS)
Thomas, Russ H.; Mengle, Vinod G.; Brunsniak, Leon; Elkoby, Ronen
2006-01-01
Propulsion airframe aeroacoustic (PAA) interactions, resulting from the integration of engine and airframe, lead to azimuthal asymmetries in the flow/acoustic field, e.g., due to the interaction between the exhaust jet flow and the pylon, the wing and its high-lift devices, such as, flaps and flaperons. In the first two parts of this series we have presented experimental results which show that isolated and installed nozzles with azimuthally varying chevrons (AVCs) can reduce noise more than conventional chevrons when integrated with a pylon and a wing with flaps at take-off conditions. In this paper, we present model-scale experimental results for the reduction of jet-flap interaction noise source due to these AVCs and document the PAA installation effects (difference in noise between installed and isolated nozzle configurations) at both approach and take-off conditions. It is found that the installation effects of both types of chevron nozzles, AVCs and conventional, are reversed at approach and take-off, in that there is more installed noise reduction at approach and less at take-off compared to that of the isolated nozzles. Moreover, certain AVCs give larger total installed noise benefits at both conditions compared to conventional chevrons. Phased microphone array results show that at approach conditions (large flap deflection, low jet speed and low ambient Mach number), chevrons gain more noise benefit from reducing jetflap interaction noise than they do from quieting the jet plume noise source which is already weak at these low jet speeds. In contrast, at take-off (small flap deflection, high jet speed and high ambient Mach number) chevrons reduce the dominant jet plume noise better than the reduction they create in jet-flap interaction noise source. In addition, fan AVCs with enhanced mixing near the pylon are found to reduce jet-flap interaction noise better than conventional chevrons at take-off.
NASA Technical Reports Server (NTRS)
Mengle, Vinod G.; Elkoby, Ronen; Brusniak, Leon; Thomas, Russ H.
2006-01-01
Propulsion airframe aeroacoustic (PAA) interactions arise due to the manner in which an engine is installed on the airframe and lead to an asymmetry in the flow/acoustic environment, for example, for under-the-wing installations due to the pylon, the wing and the high-lift devices. In this work we study how we can affect these PAA interactions to reduce the overall jet-related installed noise by tailoring the chevron shapes on fan and core nozzles in a unique fashion to take advantage of this asymmetry. In part 1 of this trio of papers we introduced the concept of azimuthally varying chevrons (AVC) and showed how some types of AVCs can be more beneficial than the conventional chevrons when tested on "isolated" scaled nozzles inclusive of the pylon effect. In this paper, we continue to study the effect of installing these AVC nozzles under a typical scaled modern wing with high-lift devices placed in a free jet. The noise benefits of these installed nozzles, as well as their installation effects are systematically studied for several fan/core AVC combinations at typical take-off conditions with high bypass ratio. We show, for example, that the top-enhanced mixing T-fan AVC nozzle (with enhanced mixing near the pylon and less mixing away from it) when combined with conventional chevrons on the core nozzle is quieter than conventional chevrons on both nozzles, and hardly produces any high-frequency lift, just as in the isolated case; however, its installed nozzle benefit is less than its isolated nozzle benefit. This suppression of take-off noise benefit under installed conditions, compared to its isolated nozzle benefit, is seen for all other chevron nozzles. We show how these relative noise benefits are related to the relative installation effects of AVCs and baseline nozzles.
NASA Astrophysics Data System (ADS)
Kim, Jandee; Lee, Jaesung; Rhee, Choong Kyun
2016-02-01
Presented is a scanning tunneling microscopy (STM) study of structural evolution of TMA/Zn2 + ion network on Au(111) to the final structure of (10√3 × 10√3) during solution phase post-modification of pristine trimesic acid (TMA) network of a (5√3 × 5√3) structure with Zn2 + ions. Coordination of Zn2 + ions into adsorbed TMA molecules transforms crown-like TMA hexamers in pristine TMA network to chevron pairs in TMA/Zn2 + ion network. Two ordered transient structures of TMA/Zn2 + ion network were observed. One is a (5√7 × 5√7) structure consisting of Zn2 + ion-containing chevron pairs and Zn2 + ion-free TMA dimers. The other is a (5√39 × 5√21) structure made of chevron pairs and chevron-pair-missing sites. An STM image showing domains of different stages of crystallization of chevron pairs demonstrates that the TMA/Zn2 + network before reaching to the final one is quite dynamic. The observed structural evolution of the TMA/Zn2 + ion network is discussed in terms of modification of configurations of adsorbed TMA as accommodating Zn2 + ions and re-ordering of Zn2 + ion-containing chevron pairs.
Performance optimization of plate heat exchangers with chevron plates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muley, A.; Manglik, R.M.
1999-07-01
The enhanced heat transfer performance of a chevron plate heat exchanger (PHE) is evaluated employing (1) energy-conservation based performance evaluation criteria (PECs), and (2) the second-law based minimization of entropy generation principle. Single-phase laminar and turbulent flow convection for three different chevron-plate arrangements are considered. The influence of plate surface corrugation characteristics and their stack arrangements on the heat exchanger's thermal-hydraulic performance is delineated. Based on the different figures of merit, the results show that the extent of heat transfer enhancement increases with flow Re and chevron angle {beta} in laminar flow, but it diminishes with increasing Re in turbulentmore » flows. With up to 2.9 times higher Q, 48% lower A, and entropy generation number N{sub s,a} {lt} 1, relative to an equivalent flat-plate pack, chevron plates are found to be especially suitable in the low to medium flow rates range (20 {le} Re {le} 2,000). Also, there appears to be no significant advantage of using a mixed-plate over a symmetric-plate arrangement.« less
West, William B.; Brabb, Earl E.; Malmborg, William T.; Parker, John M.
2009-01-01
The general location and age of more than 33,500 mostly foraminifer samples from Chevron Petroleum Company surface localities in California were provided by Brabb and Parker (2003, 2005). Malmborg and others (2008) provided digital latitude, longitude, and age for more than 13,000 of these samples. We provide here for the first time the digital latitude, longitude, and age for nearly 4,000 Chevron surface and auger samples in Washington and Oregon.
Rate of Malunion Following Bi-plane Chevron Medial Malleolar Osteotomy.
Bull, Patrick E; Berlet, Gregory C; Canini, Cameron; Hyer, Christopher F
2016-06-01
Access to the medial half of the talus can be challenging even with an osteotomy. Although several techniques are presented in the literature, critical evaluation of fixation, union, and alignment is lacking. The chevron medial malleolar osteotomy provides advantages of perpendicular instrumentation access and wide exposure to the medial talus. Postoperative displacement resulting in malunion, and possibly provoking ankle osteoarthritis, is a known complication. The present study describes our experience with the osteotomy. A consecutive series cohort of 50 bi-plane chevron osteotomies performed from 2004 to 2013 were evaluated. Forty-six were secured using 2 lag screws, and 4 were secured using 2 lag screws and a medial buttress plate. Radiographic studies performed at 2, 6, and 12 weeks and at final follow-up were analyzed for postoperative displacement, malunion, non-union, and hardware-related complications. At initial postoperative follow-up, 47 of 50 had adequate radiographs for review, and 18 of 47 (38.3%) showed some displacement when compared to the initial osteotomy fixation position. By final follow-up, 15 of 50 (30.0%) had measurable incongruence. Hardware removal was performed in 13 (26.0%) cases at an average of 2.4 years postoperation. Bi-plane medial malleolar chevron osteotomy fixed with 2 lag screws showed a 30.0% malunion rate with an average of 2 mm of incongruence on final follow-up radiographs, which is higher than what has been reported in the literature. In our practice, we now use a buttress plate and more recently have eliminated postoperative osteotomy displacement. Level IV, retrospective case series. © The Author(s) 2016.
1996-01-29
This image of Miranda, obtained by NASA Voyager 2 on approach in 1986, shows an unusual chevron figure and regions of distinctly differing terrain on the Uranian moon. http://photojournal.jpl.nasa.gov/catalog/PIA00038
78 FR 78811 - Sunshine Act Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
..., fire at the Chevron refinery that endangered 19 workers and sent more than 15,000 residents to the...-resistant metal alloys. The first interim report also found a failure by Chevron to identify and evaluate...
Compliance and stress intensity coefficients for short bar specimens with chevron notches
NASA Technical Reports Server (NTRS)
Munz, D.; Bubsey, R. T.; Srawley, J. E.
1980-01-01
For the determination of fracture toughness especially with brittle materials, a short bar specimen with rectangular cross section and chevron notch can be used. As the crack propagates from the tip of the triangular notch, the load increases to a maximum then decreases. To obtain the relation between the fracture toughness and maximum load, calculations of Srawley and Gross for specimens with a straight-through crack were applied to the specimens with chevron notches. For the specimens with a straight-through crack, an analytical expression was obtained. This expression was used for the calculation of the fracture toughness versus maximum load relation under the assumption that the change of the compliance with crack length for the specimen with a chevron notch is the same as for a specimen with a straight-through crack.
NASA Technical Reports Server (NTRS)
Oeffinger, Thomas R. (Inventor); Tocci, Leonard R. (Inventor)
1977-01-01
There is described a passive replicator device to be used in magnetic bubble domain systems. The replicator is passive, i.e., does not require an active element such as a current source or the like, and both propagates and replicates bubble domains. In a preferred embodiment, the replicator uses chevron type elements arranged in an appropriate pattern so as to interact with a pair of propagation paths wherein bubble domains are propagated. A bubble in one propagation path is routinely transferred therealong and, concurrently, replicated by the instant device into another propagation path. A plurality of elements arranged in juxtaposition to the chevrons assists in controlling the propagation of the bubbles through the respective propagation paths and, at the appropriate time, provides a cutting action wherein a bubble which is elongated between the chevrons of the two propagation paths is split into two separate bubbles.
Non-exhibition of Bragg phenomenon by chevronic sculptured thin films
NASA Astrophysics Data System (ADS)
Vepachedu, Vikas; McAtee, Patrick D.; Lakhtakia, Akhlesh
2017-08-01
The unit cell of a chevronic sculptured thin film (ChevSTF) comprises two identical columnar thin films (CTFs) except that the nanocolumns of the first are oriented at an angle Χ and nanocolumns of the second are oriented at an angle π - χ with respect to the interface of the two CTFs. A ChevSTF containing 10 unit cells was fabricated and its planewave reflectance and transmittance spectrums of this ChevSTF were measured. Despite its structural periodicity, the ChevSTF did not exhibit the Bragg phenomenon. Theoretical calculations with the CTFs modeled as biaxial dielectric materials indicated that the Bragg phenomenon would not be manifested for normal and near-normal incidence, but vestigial manifestation was possible for sufficiently oblique incidence.
Comparison of the proximal chevron and Ludloff osteotomies for the correction of hallux valgus.
Choi, Woo Jin; Yoon, Han Kook; Yoon, Hang Seob; Kim, Bom Soo; Lee, Jin Woo
2009-12-01
Although several studies have described good results of proximal chevron and Ludloff osteotomies, there have been no studies comparing the results of these two techniques at a single institution. We consecutively evaluated 46 patients who underwent proximal chevron osteotomies and 52 patients who underwent Ludloff osteotomies. Patients were evaluated by preoperative and postoperative weight bearing radiographs and the American Orthopaedic Foot and Ankle Society (AOFAS) hallux MP score. Both groups had similarly high AOFAS scores and good correction by radiographic parameters. No statistically significant differences were found with respect to correction of hallux valgus angle (HVA) and intermetatarsal angle (IMA) between the two groups. Significant shortening of the first metatarsal was found after Ludloff osteotomy (p < 0.05). At 6 weeks after surgery, the pain subscore was significantly lower in the proximal chevron group than in the Ludloff group (p < 0.05). The proximal chevron and Ludloff osteotomies yielded equivalent clinical and radiological results. The Ludloff osteotomy with lag screw fixation is more stable and does not require postoperative hardware removal, although it is technically demanding and has a tendency toward greater shortening of the first metatarsal.
Stress Intensity Factors of Semi-Circular Bend Specimens with Straight-Through and Chevron Notches
NASA Astrophysics Data System (ADS)
Ayatollahi, M. R.; Mahdavi, E.; Alborzi, M. J.; Obara, Y.
2016-04-01
Semi-circular bend specimen is one of the useful test specimens for determining fracture toughness of rock and geo-materials. Generally, in rock test specimens, initial cracks are produced in two shapes: straight-edge cracks and chevron notches. In this study, the minimum dimensionless stress intensity factors of semi-circular bend specimen (SCB) with straight-through and chevron notches are calculated. First, using finite element analysis, a suitable relation for the dimensionless stress intensity factor of SCB with straight-through crack is presented based on the normalized crack length and half-distance between supports. For evaluating the validity and accuracy of this relation, the obtained results are then compared with numerical and experimental results reported in the literature. Subsequently, by performing some experiments and also finite element analysis of the SCB specimen with chevron notch, the minimum dimensionless stress intensity factor of this specimen is obtained. Using the new equation for the dimensionless stress intensity factor of SCB with straight-through crack and an analytical method, i.e., Bluhm's slice synthesis method, the minimum (critical) dimensionless stress intensity factor of chevron notched semi-circular bend specimens is calculated. Good agreement is observed between the results of two mentioned methods.
Evaluation of strains in bituminous surfaces : stiffness-fatigue investigation.
DOT National Transportation Integrated Search
1973-01-01
The study was designed to determine if strains in Virginia's thin asphaltic pavements were high enough to cause early fatigue failure. Strains were computed with the Chevron multilayer computer program, and also measured on selected highways using el...
Klemola, Tero; Leppilahti, Juhana; Laine, Vesa; Pentikäinen, Ilkka; Ojala, Risto; Ohtonen, Pasi; Savola, Olli
2017-08-01
Hallux valgus alters gait, compromising first ray stability and function of the windlass mechanism at the late stance. Hallux valgus correction should restore the stability of the first metatarsal. Comparative studies reporting the impact of different hallux valgus correction methods on gait are rare. We report the results of a case-control study between distal chevron osteotomy and first tarsometatarsal joint derotational arthrodesis (FTJDA). Two previously studied hallux valgus cohorts were matched: distal chevron osteotomy and FTJDA. Seventy-seven feet that underwent distal chevron osteotomy (chevron group) and 76 feet that underwent FTJDA (FTJDA group) were available for follow-up, with a mean of 7.9 years (range, 5.8-9.4 years) and 5.1 years (range, 3.0-8.3 years), respectively. Matching criteria were the hallux valgus angle (HVA) and a follow-up time difference of a maximum 24 months. Two matches were made: according to the preoperative HVA and the HVA at late follow-up. Matching provided 30 and 31 pairs, respectively. Relative impulses (%) of the first toe (T1) and metatarsal heads 1 to 5 (MTH1-5), weightbearing radiographs, and American Orthopaedic Foot & Ankle Society (AOFAS) (hallux metatarsophalangeal-interphalangeal [MTP-IP]) scores were studied. The relative impulse of MTH1 was higher in the FTJDA group, whereas a central dynamic loading pattern was seen in the chevron group. This result remained when relative impulses were analyzed according to the postoperative HVA. The mean difference in the HVA at follow-up was 6.2 degrees (95% confidence interval, 3.0-9.5; P = .001) in favor of the FTJDA group. The dynamic loading capacity of MTH1 was higher in the FTJDA group in comparison to the chevron group. The follow-up HVA remained better in the FTJDA group. Level III, case-control study.
A mathematical model of the chevron-like wave pattern on a weld piece
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowden, J.; Kapadia, P.
1996-12-31
In welding processes in general the surface of a metallic weld displays a chevron-like pattern. Such a pattern is also clearly seen to be present if welding is carried out using a laser beam. In the welding process a laser beam is directed normally on the metal undergoing translation and usually penetrates it to form a keyhole. The keyhole is surrounded by a molten region, the weld pool. Even if a CO{sub 2} laser is used, there are numerous fluctuations and instabilities that occur, so that the keyhole imposes forcing frequencies on the molten weld pool, additional to vibrations attendantmore » on the process of translation. The weld pool in turn responds by supporting a spectrum of waves of different frequencies involving the natural frequency of the weld pool as well as various forcing frequencies. These waves are surface tension-type capillary waves and previous publications have attempted to model their behavior mathematically, although not all aspects of the problem have always been included. The wave pattern that is manifested in the chevron-like pattern seen on the weld piece is, however, not necessarily identical to the wave pattern present in the weld pool. This is because the chevron-like wave pattern forms as a result of several complicating effects that arise as the weld specimen cools on its surface immediately after the weld has been formed. This process involves the waves on the surface of the weld pool freezing to form the chevron-like wave pattern. A feature that is often ignored is the fact that the waves on the weld pool can only be regarded as irrotational if the translation speed is sufficiently low. This paper describes mathematically the formation of the chevron-like wave pattern based on suitable simplifying assumptions to model the process. The mathematical description of the way in which this chevron-like pattern forms is a step toward a more comprehensive understanding of this process.« less
Analysis of a Chevron Beam Thermal Actuator
NASA Astrophysics Data System (ADS)
Joshi, Amey Sanjay; Mohammed, Hussain; Kulkarni, S. M., Dr.
2018-02-01
Thermal MEMS (Micro-Electro-Mechanical Systems) actuators and sensors have a wide range of applications. The chevron type thermal actuators comparatively show superior performance over other existing electrostatic and thermal actuators. This paper describes the design and analysis of chevron type thermal actuator. Here standard design of Chevron type thermal actuator is considered which comprises of proof mass at center and array of six beams of a uniform cross section of 3 3 microns and an initial angle of 5°. The thermal actuator was designed and analyzed using analytical and finite element method and the results were compared. The model was also analyzed for initial angles of 2.5° and 7.5°, and the results were compared with FEA model. The cross section of the beam was varied and the finite element analysis of all three models was compared to suggest the best suitable thermal actuator structure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kudo, Takuya; Inoue, Tomoya; Kita, Takashi
2008-10-01
Self-assembling process of InAs/GaAs quantum dots has been investigated by analyzing reflection high-energy electron diffraction chevron images reflecting the crystal facet structure surrounding the island. The chevron image shows dramatic changes during the island formation. From the temporal evolution of the chevron tail structure, the self-assembling process has been found to consist of four steps. The initial islands do not show distinct facet structures. Then, the island surface is covered by high-index facets, and this is followed by the formation of stable low-index facets. Finally, the flow of In atoms from the islands occurs, which contributes to flatten the wettingmore » layer. Furthermore, we have investigated the island shape evolution during the GaAs capping layer growth by using the same real-time analysis technique.« less
Schuh, Reinhard; Hofstaetter, Jochen Gerhard; Benca, Emir; Willegger, Madeleine; von Skrbensky, Gobert; Zandieh, Shahin; Wanivenhaus, Axel; Holinka, Johannes; Windhager, Reinhard
2014-05-01
The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia. Recent biomechanical and clinical studies pointed out the importance of rigid fixation of proximal metatarsal osteotomies. Therefore, the aim of the present study was to compare biomechanical properties of fixation of proximal chevron osteotomies with variable locking plate and cancellous screw respectively. Ten matched pairs of human fresh frozen cadaveric first metatarsals underwent proximal chevron osteotomy with either variable locking plate or cancellous screw fixation after obtaining bone mineral density. Biomechanical testing included repetitive plantar to dorsal loading from 0 to 31 N with the 858 Mini Bionix(®) (MTS(®) Systems Corporation, Eden Prairie, MN, USA). Dorsal angulation of the distal fragment was recorded. The variable locking plate construct reveals statistically superior results in terms of bending stiffness and dorsal angulation compared to the cancellous screw construct. There was a statistically significant correlation between bone mineral density and maximum tolerated load until construct failure occurred for the screw construct (r = 0.640, p = 0.406). The results of the present study indicate that variable locking plate fixation shows superior biomechanical results to cancellous screw fixation for proximal chevron osteotomy. Additionally, screw construct failure was related to levels of low bone mineral density. Based on the results of the present study we recommend variable locking plate fixation for proximal chevron osteotomy, especially in osteoporotic bone.
Lee, K B; Cho, N Y; Park, H W; Seon, J K; Lee, S H
2015-02-01
Moderate to severe hallux valgus is conventionally treated by proximal metatarsal osteotomy. Several recent studies have shown that the indications for distal metatarsal osteotomy with a distal soft-tissue procedure could be extended to include moderate to severe hallux valgus. The purpose of this prospective randomised controlled trial was to compare the outcome of proximal and distal Chevron osteotomy in patients undergoing simultaneous bilateral correction of moderate to severe hallux valgus. The original study cohort consisted of 50 female patients (100 feet). Of these, four (8 feet) were excluded for lack of adequate follow-up, leaving 46 female patients (92 feet) in the study. The mean age of the patients was 53.8 years (30.1 to 62.1) and the mean duration of follow-up 40.2 months (24.1 to 80.5). After randomisation, patients underwent a proximal Chevron osteotomy on one foot and a distal Chevron osteotomy on the other. At follow-up, the American Orthopedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal interphalangeal (MTP-IP) score, patient satisfaction, post-operative complications, hallux valgus angle, first-second intermetatarsal angle, and tibial sesamoid position were similar in each group. Both procedures gave similar good clinical and radiological outcomes. This study suggests that distal Chevron osteotomy with a distal soft-tissue procedure is as effective and reliable a means of correcting moderate to severe hallux valgus as proximal Chevron osteotomy with a distal soft-tissue procedure. ©2015 The British Editorial Society of Bone & Joint Surgery.
Chevron Mining, Inc. McKinley Mine, Gallup, NM: NN0029386
NPDES Permit #NN0029386 for the Chevron Mining, Inc. McKinley Mine to tributaries to the Puerco River located on Tribal, private, and public lands within the Navajo Nation and near the Arizona border in New Mexico.
Publications - GMC 148 | Alaska Division of Geological & Geophysical
feet) from the Chevron USA Eagle Creek #1 well Authors: Weber, F.F. Publication Date: 1989 Publisher ., 1989, Visual kerogen and TAI data of select cuttings (1530 - 12000 feet) from the Chevron USA Eagle
Publications - GMC 75 | Alaska Division of Geological & Geophysical Surveys
DGGS GMC 75 Publication Details Title: Vitrinite reflectance data for the Chevron U.S.A. Inc. Eagle Chevron U.S.A. Inc. Eagle Creek #1 well: Alaska Division of Geological & Geophysical Surveys Geologic
Safety performance evaluation of converging chevron pavement markings : final report.
DOT National Transportation Integrated Search
2014-12-01
The objectives of this study were (1) to perform a detailed safety analysis of converging chevron : pavement markings, quantifying the potential safety benefits and developing an understanding of the : incident types addressed by the treatment, and (...
Evaluation of the effectiveness of converging chevron pavement markings.
DOT National Transportation Integrated Search
2011-10-01
Converging chevron pavement markings have recently seen rising interest in the United States as a : means to reduce speeds at high-speed locations in a desire to improve safety performance. This report : presents an investigation into the effectivene...
Evaluating the effectiveness of converging chevron pavement markings.
DOT National Transportation Integrated Search
2010-10-01
Converging chevron pavement markings have recently seen rising interest in the United States as a : means to reduce speeds at high-speed locations in a desire to improve safety performance. This report : presents an investigation into the effectivene...
Kim, Jin Su; Cho, Hun Ki; Young, Ki Won; Kim, Ji Soo; Lee, Kyung Tai
2017-12-01
Fixation of proximal chevron metatarsal osteotomy has been accomplished using K-wires traditionally and with a locking plate recently. However, both methods have many disadvantages. Hence, we developed an intramedullary fixation technique using headless cannulated screws and conducted a biomechanical study to evaluate the superiority of the technique to K-wire and locking plate fixations. Proximal chevron metatarsal osteotomy was performed on 30 synthetic metatarsal models using three fixation techniques. Specimens in group I were fixated with K-wires (1.6 mm × 2) and in group II with headless cannulated screws (3.0 mm × 2) distally through the intramedullary canal. Specimens in group III were fixated with a locking X-shaped plate (1.3-mm thick) and screws (2.5 mm × 4). Eight metatarsal specimens were selected from each group for walking fatigue test. Bending stiffness and dorsal angulation were measured by 1,000 repetitions of a cantilever bending protocol in a plantar to dorsal direction. The remaining two samples from each group were subjected to 5 mm per minute axial loading to assess the maximal loading tolerance. All samples in group I failed walking fatigue test while group II and group III tolerated the walking fatigue test. Group II showed greater resistance to bending force and smaller dorsal angulation than group III ( p = 0.001). On the axial loading test, group I and group II demonstrated superior maximum tolerance to group III (54.8 N vs. 47.2 N vs. 28.3 N). Authors have demonstrated proximal chevron metatarsal osteotomy with intramedullary screw fixation provides superior biomechanical stability to locking plate and K-wire fixations. The new technique using intramedullary screw fixation can offer robust fixation and may lead to better outcomes in surgical treatment of hallux valgus.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., Carquinez Strait, Suisun Bay, California. (a) Locations. The following areas are security zones: (1) Chevron... sea floor within approximately 100 yards of the Chevron Long Wharf, Richmond, CA, and encompasses all...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Carquinez Strait, Suisun Bay, California. (a) Locations. The following areas are security zones: (1) Chevron... sea floor within approximately 100 yards of the Chevron Long Wharf, Richmond, CA, and encompasses all...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., Carquinez Strait, Suisun Bay, California. (a) Locations. The following areas are security zones: (1) Chevron... sea floor within approximately 100 yards of the Chevron Long Wharf, Richmond, CA, and encompasses all...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., Carquinez Strait, Suisun Bay, California. (a) Locations. The following areas are security zones: (1) Chevron... sea floor within approximately 100 yards of the Chevron Long Wharf, Richmond, CA, and encompasses all...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., Carquinez Strait, Suisun Bay, California. (a) Locations. The following areas are security zones: (1) Chevron... sea floor within approximately 100 yards of the Chevron Long Wharf, Richmond, CA, and encompasses all...
76 FR 19343 - Combined Notice of Filings No. 1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... Transmission Company submits tariff filing per 154.203: Compliance NCA Chevron to be effective 2/1/2011. Filed...: Chevron U.S.A. Inc. FA0910 to be effective 4/1/ 2011. Filed Date: 03/28/2011. Accession Number: 20110328...
Wet active chevron nozzle for controllable jet noise reduction
NASA Technical Reports Server (NTRS)
Thomas, Russell H. (Inventor); Kinzie, Kevin W. (Inventor)
2011-01-01
Disposed at or toward the trailing edge of one or more nozzles associated with a jet engine are injection ports which can selectively be made to discharge a water stream into a nozzle flow stream for the purpose of increasing turbulence in somewhat of a similar fashion as mechanically disposed chevrons have done in the known art. Unlike mechanically disposed chevrons of the known art, the fluid flow may be secured thereby increasing the engine efficiency. Various flow patterns, water pressures, orifice designs or other factors can be made operative to provide desired performance characteristics.
Matsumoto, Takumi; Gross, Christopher E; Parekh, Selene G
2018-03-01
Distal Chevron osteotomy is a well-established surgical procedure for mild to moderate hallux valgus deformity. Many methods have been described for fixation of osteotomy site; secure fixation, enabling large displacement of the metatarsal head, is one of the essentials of this procedure. The purpose of the present study was to evaluate the short-term radiographic outcome of a distal Chevron osteotomy using an intramedullary plate for the correction of hallux valgus deformity. The present study evaluated 37 patients (40 feet) who underwent distal Chevron osteotomy using an intramedullary plate by periodic radiographs obtained preoperatively and at 4 weeks, 8 weeks, 3 months, and 6 months postoperatively. Correction of the hallux valgus angle averaged 17.8°, intermetatarsal angle 7.4°, distal metatarsal articular angle 2.7°, and sesamoid position 1.4 stages at 3 months postoperatively. The average lateral shift of the capital fragment was 6.5 mm. All patients achieved bone union, and there were no cases of dislocation, displacement, or avascular necrosis of the metatarsal head fragment. In conclusion, a distal Chevron osteotomy using an intramedullary plate was a favorable method for the correction of mild to moderate hallux valgus deformity. Level IV: Case series.
NASA Astrophysics Data System (ADS)
Elias, M. M.; Saidur, R.; Ben-Mansour, R.; Hepbasli, A.; Rahim, N. A.; Jesbains, K.
2018-04-01
Nanofluid is a new class of engineering fluid that has good heat transfer characteristics which is essential to increase the heat transfer performance in various engineering applications such as heat exchangers and cooling of electronics. In this study, experiments were conducted to compare the heat transfer performance and pressure drop characteristics in a plate heat exchanger (PHE) for 30° and 60° chevron angles using water based Al2O3 nanofluid at the concentrations from 0 to 0.5 vol.% for different Reynolds numbers. The thermo-physical properties has been determined and presented in this paper. At 0.5 vol% concentration, the maximum heat transfer coefficient, the overall heat transfer coefficient and the heat transfer rate for 60° chevron angle have attained a higher percentage of 15.14%, 7.8% and 15.4%, respectively in comparison with the base fluid. Consequently, when the volume concentration or Reynolds number increases, the heat transfer coefficient and the overall heat transfer coefficient as well as the heat transfer rate of the PHE (Plate Heat Exchangers) increases respectively. Similarly, the pressure drop increases with the volume concentration. 60° chevron angle showed better performance in comparison with 30° chevron angle.
Uygur, Esat; Özkan, Namık Kemal; Akan, Kaya; Çift, Hakan
2016-01-01
The aim of this prospective randomized controlled single-blind study was to compare the results of Chevron and Lindgren-Turan osteotomy techniques for treatment of moderate hallux valgus. A total of 66 female patients (34 in Chevron group, 32 Lindgren-Turan group) were recruited in this study and followed up for an average of 26.08 months. Operative procedures were performed by 2 surgeons, and patients were evaluated by an another researcher who was blinded to the surgical technique. The groups were compared for their radiological and clinical results. Both techniques was clinically and radiologically effective (p<0.01). However, no significant differences were found between the 2 groups regarding American Orthopaedic Foot and Ankle Society's clinical rating system, Painful Foot Evaluation scale of Maryland University scores, or radiologic evaluation (p>0.05). Compared to the Chevron group, the Lindgren-Turan group was found to have shorter surgical duration (p<0.05) and significantly more shortening at the first metatarsal (p<0.05). In moderate hallux valgus deformity, both the Chevron and Lindgren-Turan osteotomy techniques are clinically and radiologically safe, effective, and reliable alternatives. No superiority was detected in either technique. Although shortening at the first metatarsal in the Lindgren-Turan group was radiologically significant, the results were clinically tolerable.
Fracture toughness of brittle materials determined with chevron notch specimens
NASA Technical Reports Server (NTRS)
Shannon, J. L., Jr.; Bursey, R. T.; Munz, D.; Pierce, W. S.
1980-01-01
The use of chevron-notch specimens for determining the plane strain fracture toughness (K sub Ic) of brittle materials is discussed. Three chevron-notch specimens were investigated: short bar, short rod, and four-point-bend. The dimensionless stress intensity coefficient used in computing K sub Ic is derived for the short bar specimen from the superposition of ligament-dependent and ligament-independent solutions for the straight through crack, and also from experimental compliance calibrations. Coefficients for the four-point-bend specimen were developed by the same superposition procedure, and with additional refinement using the slice model of Bluhm. Short rod specimen stress intensity coefficients were determined only by experimental compliance calibration. Performance of the three chevron-notch specimens and their stress intensity factor relations were evaluated by tests on hot-pressed silicon nitride and sintered aluminum oxide. Results obtained with the short bar and the four-point-bend specimens on silicon nitride are in good agreement and relatively free of specimen geometry and size effects within the range investigated. Results on aluminum oxide were affected by specimen size and chevron-notch geometry, believed due to a rising crack growth resistance curve for the material. Only the results for the short bar specimen are presented in detail.
Smectic C chevrons in nanocylinders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lefort, R., E-mail: ronan.lefort@univ-rennes1.fr; Morineau, D.; Jean, F.
2014-11-17
The structure of an achiral smectic-C liquid crystal confined in nanocylinders with a planar surface anchoring is studied by small angle neutron scattering. We observe an invariant alignment of the nematic director with the pore axis, that promotes an original chevron structure with revolution symmetry.
Relative strength of tailor's bunion osteotomies and fixation techniques.
Haddon, Todd B; LaPointe, Stephan J
2013-01-01
A paucity of data is available on the mechanical strength of fifth metatarsal osteotomies. The present study was designed to provide that information. Five osteotomies were mechanically tested to failure using a materials testing machine and compared with an intact fifth metatarsal using a hollow saw bone model with a sample size of 10 for each construct. The osteotomies tested were the distal reverse chevron fixated with a Kirschner wire, the long plantar reverse chevron osteotomy fixated with 2 screws, a mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, the mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, and an additional cerclage wire and a transverse closing wedge osteotomy fixated with a box wire technique. Analysis of variance was performed, resulting in a statistically significant difference among the data at p <.0001. The Tukey-Kramer honestly significant difference with least significant differences was performed post hoc to separate out the pairs at a minimum α of 0.05. The chevron was statistically the strongest construct at 130 N, followed by the long plantar osteotomy at 78 N. The chevron compared well with the control at 114 N, and they both fractured at the proximal model to fixture interface. The other osteotomies were statistically and significantly weaker than both the chevron and the long plantar constructs, with no statistically significant difference among them at 36, 39, and 48 N. In conclusion, the chevron osteotomy was superior in strength to the sagittal and transverse plane osteotomies and similar in strength and failure to the intact model. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Chen, Tao; Chan, Hue Sun
2015-01-01
The bacterial colicin-immunity proteins Im7 and Im9 fold by different mechanisms. Experimentally, at pH 7.0 and 10°C, Im7 folds in a three-state manner via an intermediate but Im9 folding is two-state-like. Accordingly, Im7 exhibits a chevron rollover, whereas the chevron arm for Im9 folding is linear. Here we address the biophysical basis of their different behaviors by using native-centric models with and without additional transferrable, sequence-dependent energies. The Im7 chevron rollover is not captured by either a pure native-centric model or a model augmented by nonnative hydrophobic interactions with a uniform strength irrespective of residue type. By contrast, a more realistic nonnative interaction scheme that accounts for the difference in hydrophobicity among residues leads simultaneously to a chevron rollover for Im7 and an essentially linear folding chevron arm for Im9. Hydrophobic residues identified by published experiments to be involved in nonnative interactions during Im7 folding are found to participate in the strongest nonnative contacts in this model. Thus our observations support the experimental perspective that the Im7 folding intermediate is largely underpinned by nonnative interactions involving large hydrophobics. Our simulation suggests further that nonnative effects in Im7 are facilitated by a lower local native contact density relative to that of Im9. In a one-dimensional diffusion picture of Im7 folding with a coordinate- and stability-dependent diffusion coefficient, a significant chevron rollover is consistent with a diffusion coefficient that depends strongly on native stability at the conformational position of the folding intermediate. PMID:26016652
The Role of Crack Formation in Chevron-Notched Four-Point Bend Specimens
NASA Technical Reports Server (NTRS)
Calomino, Anthony M.; Ghosn, Louis J.
1994-01-01
The failure sequence following crack formation in a chevron-notched four-point bend 1 specimen is examined in a parametric study using the Bluhm slice synthesis model. Premature failure resulting from crack formation forces which exceed those required to propagate a crack beyond alpha (min) is examined together with the critical crack length and critical crack front length. An energy based approach is used to establish factors which forecast the tendency of such premature failure due to crack formation for any selected chevron-notched geometry. A comparative study reveals that, for constant values of alpha (1) and alpha (0), the dimensionless beam compliance and stress intensity factor are essentially independent of specimen width and thickness. The chevron tip position, alpha (0) has its primary effect on the force required to initiate a sharp crack. Small values for alpha (0) maximize the stable region length, however, the premature failure tendency is also high for smaller alpha (0) values. Improvements in premature failure resistance can be realized for larger values of alpha (0) with only a minor reduction in the stable region length. The stable region length is also maximized for larger chevron based positions, alpha (1) but the chance for premature failure is also raised. Smaller base positions improve the premature failure resistance with only minor decreases in the stable region length. Chevron geometries having a good balance of premature failure resistance, stable region length, and crack front length are 0.20 less than or equal to alpha (0) is less than or equal to 0.30 and 0.70 is less than or equal to alpha (1) is less than or equal to 0.80.
Kailer, Andreas; Stephan, Marc
2016-10-01
The fracture toughness determination of fine-grained zirconia ceramics using the chevron notched beam method (CNB) was investigated to assess the feasibility of this method for quality assurance and material characterization. CNB tests were performed using four different yttria-stabilized zirconia ceramics under various testing modes and conditions, including displacement-controlled and load-rate-controlled four point bending to assess the influence of slow crack growth and identify most suitable test parameters. For comparison, tests using single-edge V-notch beams (SEVNB) were conducted. It was observed that the CNB method yields well-reproducible results. However, slow crack growth effects significantly affect the measured KIC values, especially when slow loading rates are used. To minimize the effect of slow crack growth, the application of high loading rates is recommended. Despite a certain effort needed for setting up a sample preparation routine, the CNB method is considered to be very useful for measuring and controlling the fracture toughness of zirconia ceramics. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
A chevron beam-splitter interferometer
NASA Technical Reports Server (NTRS)
Breckinridge, J. B.
1979-01-01
Fully tilt compensated double-pass chevron beam splitter, that removes channelling effects and permits optical phase tuning, is wavelength independent and allows small errors in alignment that are not tolerated in Michelson, Machzender, or Sagnac interferometers. Device is very useful in experiments where background vibration affects conventional interferometers.
33 CFR 147.825 - Chevron Genesis Spar safety zone.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Description. The Chevron Genesis Spar, Green Canyon 205A (GC205A), is located at position 27°46′46.365″ N, 90... is a safety zone. (b) Regulation. No vessel may enter or remain in this safety zone except the...
Evaluation of an Innovative Fixation System for Chevron Bunionectomy.
Bennett, Gordon L; Sabetta, James A
2016-02-01
Distal chevron metatarsal osteotomy bunionectomy is a commonly performed procedure for the treatment of mild to moderate hallux valgus deformity. There are several different methods to stabilize this osteotomy. We evaluated a new intramedullary plate system. We prospectively evaluated 57 consecutive patients who underwent distal chevron metatarsal osteotomy bunionectomy utilizing the intramedullary plate system. All operative procedures were performed by the senior author. Patients were evaluated preoperatively, postoperatively, and at a final follow-up utilizing the American Orthopaedic Foot & Ankle Society (AOFAS) forefoot scoring system. Sixty-three surgically corrected feet went on to heal the osteotomy site. There were no hardware failures. We had one patient that expressed mild discomfort over the plate. All patients significantly improved their AOFAS scores compared with preoperative values. We concluded that the distal chevron metatarsal osteotomy bunionectomy resulted in excellent function and pain relief. The new plate system was a reliable and stable implant with a low profile, good strength, and ease of use. Level IV, retrospective case series. © The Author(s) 2015.
Magnetic, electronic and optical properties of different graphene, BN and BC2N nanoribbons
NASA Astrophysics Data System (ADS)
Guerra, T.; Leite, L.; Azevedo, S.; de Lima Bernardo, B.
2017-04-01
Graphene nanoribbons are predicted to be essential components in future nanoelectronics. The size, edge type, form, arrangement of atoms and width of nanoribbons drastically change their properties. However, magnetic, electronic and optical properties of armchair, chevron and sawtooth of graphene, BN and BC2N nanoribbons are not fully understood so far. Here, we make use of first-principles calculations based on the density functional theory (DFT) to investigate the structural, magnetic, electronic and optical properties of nanoribbons of graphene, boron nitride and BC2N with armchair edge, chevron-type and sawtooth forms. The lowest formation energies were found for the armchair and chevron nanoribbons of graphene and boron nitride. We have shown that the imbalance of carbon atoms between different sublattices generates a net magnetic moment. Chevron-type nanoribbons of BC2N and graphene showed a band gap comparable with silicon, and a high light absorption in the visible spectrum when compared to the other configurations.
Akpinar, Evren; Buyuk, Abdul Fettah; Cetinkaya, Engin; Gursu, Sarper; Ucpunar, Hanifi; Albayrak, Akif
2016-01-01
The goal of distal chevron osteotomy for hallux valgus is to restore proper first-toe joint alignment by performing lateral translation of the distal first metatarsal fragment (the metatarsal head). We hypothesized that in some patients this procedure might also result in involuntary medial translation of the proximal first metatarsal fragment, which we called proximal intermetatarsal divergence. The aim of the present study was to compare the pre- and postoperative radiographs of patients with hallux valgus to determine whether we could identify proximal intermetatarsal divergence. We retrospectively compared the pre- and postoperative radiographs of 29 feet in 28 patients treated with distal chevron osteotomy. Two different methods were used to measure the intermetatarsal angles: the anatomic intermetatarsal angle (aIMA) and the mechanical intermetatarsal angle (mIMA). The maximum intermetatarsal distance (MID) was also measured. We defined proximal intermetatarsal divergence as a postoperative increase in the aIMA or MID, coupled with a decrease in the mIMA. For data analysis, we divided the patients into low-angle (mild deformity) and high-angle (severe deformity) groups, according to their preoperative mIMA. The mean ± standard deviation patient age was 41 ± 14 years. In the low-angle group, the mean mIMA decreased (from 10.91° to 7.00°), the mean aIMA increased (from 11.80° to 13.55°), and the mean MID increased (from 17.97 mm to 20.60 mm; p = .001, for all). In the high-angle group, the mean mIMA decreased (from 14.30° to 6.90°; p = .001), the mean aIMA decreased (from 14.77° to 13.54°; p = .06), and the mean MID decreased (from 20.74 mm to 20.37 mm; p = .64). The results of our study suggest that proximal intermetatarsal divergence might occur after distal chevron osteotomy for hallux valgus, primarily in patients with a low preoperative mIMA. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Chevron starts U.S. gulf`s first Lower Cretaceous flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petzet, G.A.
1998-06-15
Chevron plans to start production from its Mobile 991 No. 1 well this month. The trend`s first producer is the Viosca Knoll 68 No. 2 well, which went on line April 26 at the anticipated rate of about 15 MMcfd of gas. Chevron has also tested its Viosca Knoll 114 discovery well, drilled in August 1997. Five gas discoveries since 1994 in a trend that extends now Mobile Block 991 to Viosca Knoll Block 252 have recoverable reserve potential of over 600 bcf (gross trend) of natural gas. The paper describes the carbonate trend and exploring the Lower Cretaceous Jamesmore » deposit.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2004-05-01
In an energy-efficiency study at its refinery near Salt Lake City, Utah, Chevron focused on light hydrocarbons processing. The company found it could recover hydrocarbons from its fuel gas system and sell them. By using process simulation models of special distillation columns and associated reboilers and condensers, Chevron could predict the performance of potential equipment configuration changes and process modifications. More than 25,000 MMBtu in natural gas could be saved annually if a debutanizer upgrade project and a new saturated gas plant project were completed. Together, these projects would save $4.4 million annually.
Hazardous Waste Cleanup: Chevron Chemical Company in South Plainfield, New Jersey
The Chevron Chemical Co. occupies approximately 19 acres in an industrial area of South Plainfield, New Jersey. The facility is bordered on the east by Conrail Property (railroad) and the Hummel Chemical Co.; on the south by a tributary of Bound Brook and
Matzaroglou, Charalambos; Bougas, Panagiotis; Panagiotopoulos, Elias; Saridis, Alkis; Karanikolas, Menelaos; Kouzoudis, Dimitris
2010-01-01
Hallux valgus is a very common foot disorder, with its prevalence estimated at 33% in adult shoe-wearing populations. Conservative management is the initial treatment of choice for this condition, but surgery is sometimes needed. The 600 angle Chevron osteotomy is an accepted method for correction of mild to moderate hallux valgus in adults less than 60 years old. A modified 900 angle Chevron osteotomy has also been described; this modified technique can confer some advantages compared to the 600 angle method, and reported results are good. In the current work we present clinical data from a cohort of fifty-one female patients who had surgery for sixty-two hallux valgus deformities. In addition, in order to get a better physical insight and study the mechanical stresses along the two osteotomies, Finite Element Analysis (FEA) was also conducted. FEA indicated enhanced mechanical bonding with the modified 900 Chevron osteotomy, because the compressive stresses that keep the two bone parts together are stronger, and the shearing stresses that tend to slide the two bone parts apart are weaker, compared to the typical 600 technique. Follow-up data on our patient cohort show good or excellent long-term clinical results with the modified 900 angle technique. These results are consistent with the FEA-based hypothesis that a 900 Chevron osteotomy confers certain mechanical advantages compared to the typical 600 procedure. PMID:20648223
Noise Measurements of High Aspect Ratio Distributed Exhaust Systems
NASA Technical Reports Server (NTRS)
Bridges, James
2015-01-01
This paper covers far-field acoustic measurements of a family of rectangular nozzles with aspect ratio 8, in the high subsonic flow regime. Several variations of nozzle geometry, commonly proposed for embedded exhaust systems, are explored, including bevels, slants, single broad chevrons and notches, and internal septae. Far-field acoustic results, presented previously for the simple rectangular nozzle, showed that increasing aspect ratio increases the high frequency noise, especially directed in the plane containing the minor axis of the nozzle. Detailed changes to the nozzle geometry generally made little difference in the noise, and the differences were greatest at low speed. Having an extended lip on one broad side ('bevel') did produce up to 3dB more noise in all directions, while extending the lip on the narrow side ('slant') produced up to 2dB more noise, primarily on the side with the extension. Adding a single, non-intrusive chevron, made no significant change to the noise, while inverting the chevron ('notch') produced up to 2dB increase in the noise. Having internal walls ('septae') within the nozzle, such as would be required for structural support or when multiple fan ducts are aggregated, reduced the noise of the rectangular jet, but could produce a highly directional shedding tone from the septae trailing edges. Finally, a nozzle with both septae and a beveled nozzle, representative of the exhaust system envisioned for a distributed propulsion aircraft with a common rectangular duct, produced almost as much noise as the beveled nozzle, with the septae not contributing much reduction in noise.
Noise Measurements of High Aspect Ratio Distributed Exhaust Systems
NASA Technical Reports Server (NTRS)
Bridges, James E.
2015-01-01
This paper covers far-field acoustic measurements of a family of rectangular nozzles with aspect ratio 8, in the high subsonic flow regime. Several variations of nozzle geometry, commonly found in embedded exhaust systems, are explored, including bevels, slants, single broad chevrons and notches, and internal septae. Far-field acoustic results, presented previously for the simple rectangular nozzle, showed that increasing aspect ratio increases the high frequency noise, especially directed in the plane containing the minor axis of the nozzle. Detailed changes to the nozzle geometry generally made little difference in the noise, and the differences were greatest at low speed. Having an extended lip on one broad side (bevel) did produce up to 3 decibels more noise in all directions, while extending the lip on the narrow side (slant) produced up to 2 decibels more noise, primarily on the side with the extension. Adding a single, non-intrusive chevron, made no significant change to the noise, while inverting the chevron (notch) produced up to 2decibels increase in the noise. Having internal walls (septae) within the nozzle, such as would be required for structural support or when multiple fan ducts are aggregated, reduced the noise of the rectangular jet, but could produce a highly directional shedding tone from the septae trailing edges. Finally, a nozzle with both septae and a beveled nozzle, representative of the exhaust system envisioned for a distributed electric propulsion aircraft with a common rectangular duct, produced almost as much noise as the beveled nozzle, with the septae not contributing much reduction in noise.
Analysis of some compliance calibration data for chevron-notch bar and rod specimens
NASA Technical Reports Server (NTRS)
Orange, Thomas W.; Bubsey, Raymond T.; Pierce, William S.; Shannon, John L., Jr.
1991-01-01
A set of equations describing certain fracture mechanics parameters for chevron-notch bar and rod specimens are presented. They are developed by fitting earlier compliance calibration data. The difficulty in determining the minimum stress intensity coefficient and the critical crack length is discussed.
Networking among Chevron Libraries.
ERIC Educational Resources Information Center
Linden, Margaret J.
1989-01-01
Describes the process by which librarians at the Chevron and Gulf Oil Corporations managed the merger of corporation libraries and developed a framework for a company-wide library network. The discussion covers corporate policies for information exchange, shared resources, and cost control, and examines factors that led to the success of the…
NASA Technical Reports Server (NTRS)
1994-01-01
After concluding an oil exploration agreement with the Republic of Yemen, Chevron International needed detailed geologic and topographic maps of the area. Chevron's remote sensing team used imagery from Landsat and SPOT, combining images into composite views. The project was successfully concluded and resulted in greatly improved base maps and unique topographic maps.
Hazardous Waste Cleanup: Chevron Phillips Chemical Puerto Rico Core in Guayama, Puerto Rico
Chevron Phillips Chemical Puerto Rico Core (CPCPRC) plant is located on Road 710, km 1.3, approximately 2.5 miles southwest of Guayama, Puerto Rico, and northeast of Las Mareas Harbor. CPCPRC has operated at the Guayama site since 1966. The Guamani River
Lost Hills Field Trial - incorporating new technology for resevoir management
NASA Technical Reports Server (NTRS)
Fielding, E. J.; Brink, J. L.; Patzek, T. W.; Silin, D. B.
2002-01-01
This paper will discuss how Chevron U.S.A. Production Company is implementing a field trial that will use Supervisory Control and Data Acquisition (SCADA)on injection wells, in conjunction with satellite images to measure ground elevation changes, to perform real-time resevoir management in the Lost Hills Field.
Development of plane strain fracture toughness test for ceramics using Chevron notched specimens
NASA Technical Reports Server (NTRS)
Bubsey, R. T.; Shannon, J. L., Jr.; Munz, D.
1983-01-01
Chevron-notched four-point-bend and short-bar specimens have been used to determine the fracture toughness of sintered aluminum oxide and hot-pressed silicon nitride ceramics. The fracture toughness for Si3N4 is found to be essentially independent of the specimen size and chevron notch configuration, with values ranging from 4.6 to 4.9 MNm exp -3/2. In contrast, significant specimen size and notch geometry effects have been observed for Al2O3, with the fracture toughness ranging from 3.1 to 4.7 MNm exp -3/2. These effects are attributed to a rising crack growth resistance curve for the Al2O3 tested.
Single absorbable polydioxanone pin fixation for distal chevron bunion osteotomies.
Deorio, J K; Ware, A W
2001-10-01
The distal chevron osteotomy is a well-established technique for correction of symptomatic mild to moderate metatarsus primus varus with hallux valgus deformity. Fixation of the osteotomy ranges from none to bone pegs, Kirschner wires, screws, or absorbable pins. We evaluated one surgeon's (J.K.D.) results of distal chevron osteotomy fixation with a single, nonpredrilled, 1.3-mm poly-p-dioxanone pin and analyzed any differences in patients with unilateral or bilateral symptomatic metatarsus primus varus with hallux valgus deformities. All osteotomies healed without evidence of infection, osteolysis, nonunion, or necrosis. Equal correction was achieved in unilateral and bilateral procedures. The technique is quick and easy, and adequate fixation is achieved.
ERIC Educational Resources Information Center
Wang, Jianjun
2013-01-01
Since 2007, Chevron has funded the Research Experience Vitalizing Science -- University Program (REVS-UP), which lasts four weeks each summer to develop Science, Technology, Engineering, and Mathematics (STEM) projects at CSUB [California State University, Bakersfield]. Over the past six years, a total of 26 STEM professors have led the…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-13
... megawatt (MW) solar photovoltaic project which would connect to an existing Southern California Edison 33... Solutions Lucerne Valley Solar Project, California and the Proposed Amendment to the California Desert... Chevron Energy Solutions Lucerne Valley Solar Project and by this notice is announcing its availability...
Publications - GMC 160 | Alaska Division of Geological & Geophysical
Publications Geologic Materials Center General Information Inventory Monthly Report Hours and Location Policy DGGS GMC 160 Publication Details Title: A geochemical summary report of cuttings from the Chevron USA Schiefelbein, C.F., 1990, A geochemical summary report of cuttings from the Chevron USA Inc. Koniag #1 well
Evaluation of channelizing devices for work zones : type II barricades and chevron panels.
DOT National Transportation Integrated Search
1982-01-01
The objectives of this research were (1) to evaluate the 4-in. (10.2-cm) and 6-in. (15.2-cm) wide alternating diagonal stripes on barricade rails less than 3 ft. (0.92-m) long, and (2) to select the most effective chevron panel. A secondary objective...
Modified Chevron osteotomy for hallux valgus deformity in female athletes. A 2-year follow-up study.
Giotis, Dimitrios; Paschos, Nikolaos K; Zampeli, Franceska; Giannoulis, Dionisios; Gantsos, Apostolos; Mantellos, George
2016-09-01
Hallux valgus is an increasingly common deformity in young female athletes that constricts their daily athletic activities and influences foot cosmesis. The aim of this study was to evaluate the outcome of modified Chevron osteotomy for hallux valgus deformity in this specific population. Forty-two cases of modified Chevron osteotomies were carried out in 33 patients with mild to moderate hallux valgus deformity. Each participant was evaluated for AOFAS score, pain, range of motion, cosmetic and radiological outcome. Mean AOFAS score improved to 96.3 (p<0.001) while the mean range of motion of the metatarsophalangeal joint was maintained (p=0.138). The cosmetic result was excellent/good in 40 cases (95%). Mean metatarsophalangeal and intermetatarsal angles were decreased from 29.8° and 14.2° preoperatively to 12.2° and 8.1° postoperatively (p<0.001 and p<0.036), respectively. Modified Chevron osteotomy could offer substantial correction of hallux valgus deformity in young female athletes, with excellent clinical outcome. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Boeing's variable geometry chevron: morphing aerospace structures for jet noise reduction
NASA Astrophysics Data System (ADS)
Calkins, Frederick T.; Mabe, James H.; Butler, George W.
2006-03-01
Boeing is applying cutting edge smart material actuators to the next generation morphing technologies for aircraft. This effort has led to the Variable Geometry Chevrons (VGC), which utilize compact, light weight, and robust shape memory alloy (SMA) actuators. These actuators morph the shape of chevrons on the trailing edge of a jet engine in order to optimize acoustic and performance objectives at multiple flight conditions. We have demonstrated a technical readiness level of 7 by successfully flight testing the VGCs on a Boeing 777-300ER with GE-115B engines. In this paper we describe the VGC design, development and performance during flight test. Autonomous operation of the VGCs, which did not require a control system or aircraft power, was demonstrated. A parametric study was conducted showing the influence of VGC configurations on shockcell generated cabin noise reduction during cruise. The VGC system provided a robust test vehicle to explore chevron configurations for community and shockcell noise reduction. Most importantly, the VGC concept demonstrated an exciting capability to optimize jet nozzle performance at multiple flight conditions.
Matzaroglou, Charalambos; Bougas, Panagiotis; Panagiotopoulos, Elias; Saridis, Alkis; Karanikolas, Menelaos; Kouzoudis, Dimitris
2010-04-22
Hallux valgus is a very common foot disorder, with its prevalence estimated at 33% in adult shoe-wearing populations. Conservative management is the initial treatment of choice for this condition, but surgery is sometimes needed. The 60(0) angle Chevron osteotomy is an accepted method for correction of mild to moderate hallux valgus in adults less than 60 years old. A modified 90(0) angle Chevron osteotomy has also been described; this modified technique can confer some advantages compared to the 60(0) angle method, and reported results are good. In the current work we present clinical data from a cohort of fifty-one female patients who had surgery for sixty-two hallux valgus deformities. In addition, in order to get a better physical insight and study the mechanical stresses along the two osteotomies, Finite Element Analysis (FEA) was also conducted. FEA indicated enhanced mechanical bonding with the modified 90(0) Chevron osteotomy, because the compressive stresses that keep the two bone parts together are stronger, and the shearing stresses that tend to slide the two bone parts apart are weaker, compared to the typical 60(0) technique. Follow-up data on our patient cohort show good or excellent long-term clinical results with the modified 90(0) angle technique. These results are consistent with the FEA-based hypothesis that a 90(0) Chevron osteotomy confers certain mechanical advantages compared to the typical 60(0) procedure.
Toxicity of Chevron Escravos crude oil and chemical dispersant on guinea pig testicular function.
Afonne, Onyenmechi Johnson; Onyiaorah, Igwebuike Victor; Orisakwe, Orish Ebere
2013-01-01
Chemical contaminants have been found to affect reproductive functions in mammals. This study investigated the effect of Chevron Escravos crude oil and Emulsol L.W. dispersant on the testicular functions of guinea pig. Eight groups of seven sexually mature male guinea pigs each were given 1250, 2500, or 5000 mg/kg of crude oil and dispersant for 7 days. The fluid and food intake and body weight of the animals were measured daily throughout the study. After the exposure period, sperm quality analysis was carried out, and fructose and lactate dehydrogenase were analyzed in tissue homogenate, while testosterone and estradiol were assayed in blood. The right testis was also processed for histological analysis. The epididymal sperm number and fructose level of treated animals showed a significant dose-dependent decrease (p<0.05) compared with controls. Also, sperm motility and morphology were altered in the treated groups, while testosterone and estradiol levels were increased significantly (p<0.05) in the treated groups. Histological examination showed signs of toxicity in the treated animals. From the findings, it was evident that Chevron Escravos crude oil and Emulsol L.W. oil dispersant are able to cause acute testicular toxicity in guinea pigs. The possible mechanism of toxicity is suggested to be by stimulation of hormone production from the adrenal cortex, causing a negative feedback on gonadotropin-releasing hormone in the pituitary gland to suppress spermatogenesis.
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Hoff, G. E.; Barter, J. W.; Martens, S.; Gliebe, P. R.; Mengle, V.; Dalton, W. N.; Saiyed, Naseem (Technical Monitor)
2000-01-01
This report describes the work performed by General Electric Aircraft Engines (GEAE) and Allison Engine Company (AEC) on NASA Contract NAS3-27720 AoI 14.3. The objective of this contract was to generate quality jet noise acoustic data for separate-flow nozzle models and to design and verify new jet-noise-reduction concepts over a range of simulated engine cycles and flight conditions. Five baseline axisymmetric separate-flow nozzle models having bypass ratios of five and eight with internal and external plugs and 11 different mixing-enhancer model nozzles (including chevrons, vortex-generator doublets, and a tongue mixer) were designed and tested in model scale. Using available core and fan nozzle hardware in various combinations, 28 GEAE/AEC separate-flow nozzle/mixing-enhancer configurations were acoustically evaluated in the NASA Glenn Research Center Aeroacoustic and Propulsion Laboratory. This report describes model nozzle features, facility and data acquisition/reduction procedures, the test matrix, and measured acoustic data analyses. A number of tested core and fan mixing enhancer devices and combinations of devices gave significant jet noise reduction relative to separate-flow baseline nozzles. Inward-flip and alternating-flip core chevrons combined with a straight-chevron fan nozzle exceeded the NASA stretch goal of 3 EPNdB jet noise reduction at typical sideline certification conditions.
Blood supply to the first metatarsal head and vessels at risk with a chevron osteotomy.
Malal, J J George; Shaw-Dunn, J; Kumar, C Senthil
2007-09-01
Chevron osteotomy, a commonly performed procedure for the treatment of hallux valgus, results in osteonecrosis of the first metatarsal head in 0% to 20% of cases. The aim of this study was to map out the arrangement of the vascular supply to the first metatarsal head and its relationship to the limbs of the chevron osteotomy. Ten cadaveric lower limbs were injected with an India ink-latex mixture, and the feet were dissected to assess the blood supply to the first metatarsal head. The dissection was carried out by tracing the branches of the dorsalis pedis and posterior tibial vessels. A distal chevron osteotomy was mapped, with the limbs of the osteotomy set at an angle of 60 degrees from the geometric center of the first metatarsal head. The relationship of the limbs of the osteotomy to the blood vessels was recorded. The first metatarsal head was found to be supplied by branches from the first dorsal metatarsal, first plantar metatarsal, and medial plantar arteries. The first dorsal metatarsal artery was the dominant vessel among the three arteries in eight specimens. All of the vessels formed a plexus at the plantar-lateral aspect of the metatarsal neck, just proximal to the capsular attachment, with a varying number of branches from the plexus then entering the metatarsal head. The plantar limb of the proposed chevron cuts exited through this plexus of vessels in all specimens. Contrary to the widely held view, only minor vascular branches could be found entering the dorsal aspect of the neck. The identification of the plantar-lateral corner of the metatarsal neck as the major site of vascular ingress into the first metatarsal head suggests that constructing the chevron osteotomy with a long plantar limb exiting well proximal to the capsular attachment may decrease the postoperative prevalence of osteonecrosis of the first metatarsal head.
Flight Test Results for Uniquely Tailored Propulsion-Airframe Aeroacoustic Chevrons: Shockcell Noise
NASA Technical Reports Server (NTRS)
Mengle, Vinod G.; Ganz, Ulrich W.; Nesbitt, Eric; Bultemeier, Eric J.; Thomas, Russell H.; Nesbitt, Eric
2006-01-01
Azimuthally varying chevrons (AVC) which have been uniquely tailored to account for the asymmetric propulsion-airframe aeroacoustic interactions have recently shown significant reductions in jet-related community noise at low-speed take-off conditions in scale model tests of coaxial nozzles with high bypass ratio. There were indications that such AVCs may also provide shockcell noise reductions at high cruise speeds. This paper describes the flight test results when one such AVC concept, namely, the T-fan chevrons with enhanced mixing near the pylon, was tested at full-scale on a modern large twin-jet aircraft (777-300ER) with focus on shockcell noise at mid-cruise conditions. Shockcell noise is part of the interior cabin noise at cruise conditions and its reduction is useful from the viewpoint of passenger comfort. Noise reduction at the source, in the exhaust jet, especially, at low frequencies, is beneficial from the perspective of reduced fuselage sidewall acoustic lining. Results are shown in terms of unsteady pressure spectra both on the exterior surface of the fuselage at several axial stations and also microphone arrays placed inside the fuselage aft of the engine. The benefits of T-fan chevrons, with and without conventional chevrons on the core nozzle, are shown for several engine operating conditions at cruise involving supersonic fan stream and subsonic or supersonic core stream. The T-fan AVC alone provides up to 5 dB low-frequency noise reduction on the fuselage exterior skin and up to 2 dB reduction inside the cabin. Addition of core chevrons appears to increase the higher frequency noise. This flight test result with the previous model test observation that the T-fan AVCs have hardly any cruise thrust coefficient loss (< 0.05%) make them viable candidates for reducing interior cabin noise in high bypass ratio engines.
Minimally Invasive and Open Distal Chevron Osteotomy for Mild to Moderate Hallux Valgus.
Brogan, Kit; Lindisfarne, Edward; Akehurst, Harold; Farook, Usama; Shrier, Will; Palmer, Simon
2016-11-01
Minimally invasive surgical (MIS) techniques are increasingly being used in foot and ankle surgery but it is important that they are adopted only once they have been shown to be equivalent or superior to open techniques. We believe that the main advantages of MIS are found in the early postoperative period, but in order to adopt it as a technique longer-term studies are required. The aim of this study was to compare the 2-year outcomes of a third-generation MIS distal chevron osteotomy with a comparable traditional open distal chevron osteotomy for mild-moderate hallux valgus. Our null hypothesis was that the 2 techniques would yield equivalent clinical and radiographic results at 2 years. This was a retrospective cohort study. Eighty-one consecutive feet (49 MIS and 32 open distal chevron osteotomies) were followed up for a minimum 24 months (range 24-58). All patients were clinically assessed using the Manchester-Oxford Foot Questionnaire. Radiographic measures included hallux valgus angle, the intermetatarsal angle, hallux interphalangeal angle, metatarsal phalangeal joint angle, distal metatarsal articular angle, tibial sesamoid position, shape of the first metatarsal head, and plantar offset. Statistical analysis was done using Student t test or Wilcoxon rank-sum test for continuous data and Pearson chi-square test for categorical data. Clinical and radiologic postoperative scores in all domains were substantially improved in both groups (P < .001), but there was no statistically significant difference in improvement of any domain between open and MIS groups (P > .05). There were no significant differences in complications between the 2 groups ( > .5). The midterm results of this third-generation technique show that it was a safe procedure with good clinical outcomes and comparable to traditional open techniques for symptomatic mild-moderate hallux valgus. Level III, retrospective comparative study. © The Author(s) 2016.
Chen, Xue-Qiang; Wu, Qun-Feng; Dong, Wei-Qin; Yu, Li-Xin; Li, Xiong-Feng
2018-03-25
To explore clinical effect of modified Chevron osteotomy combined with lateral tissue loosening for the treatment of mild-moderate hallux valgus through internal signal approach. From July 2015 to June 2016, 26 patients with mild-moderate hallux valgus treated with modified Chevron osteotomy combined with lateral tissue loosening through internal signal approach, including 2 males and 24 females aged from 45 to 65 years old with an average of(54.6±4.8) years old;the courses of diseases ranged from 1 to 5 months with an average of (7.5±3.3) months. Hallux valgus angle(HVA), inter metatarsal angle(IMA) were measured at 12 months after operation, and AOFAS score was applied to evaluate clinical effect before and after operation. All incisions were healed at stage I. No incision occurred infection, metatarsal necrosis and recurrence of hallux valgus deformity. Two patients occurred skin numbness caused by musculocutaneous nerve injury. Twenty-six patients were followed up from 6 to 12 months with an average of(9.12±2.06) months. HVA, IMA were(30.01±3.71)°, (14.00±1.50)° before operation and(9.41±4.16)°, (7.00±0.60)° after operation, which had significant difference. There was statistical significance in AOFAS score before operation 54.77±9.59 and after operation 92.73±5.47, and 19 cases obtained excellent results and 7 moderate. Modified Chevron osteotomy combined with full thread headless pressure screw fixation and lateral tissue loosening for the treatment of mild-moderate hallux valgus has advantages of excellent exposure, simple operation, stable fixation, rapid recovery. Akin osteotomy with internal capsulorrhaphy were used with lateral loosening and could recover soft tissue balance between lateral and internal, and could receive satisfied clinical effects. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
Kim, Jin Su; Young, Ki Won; Kim, Ji Soo; Lee, Kyung Tai
2017-01-01
Background Fixation of proximal chevron metatarsal osteotomy has been accomplished using K-wires traditionally and with a locking plate recently. However, both methods have many disadvantages. Hence, we developed an intramedullary fixation technique using headless cannulated screws and conducted a biomechanical study to evaluate the superiority of the technique to K-wire and locking plate fixations. Methods Proximal chevron metatarsal osteotomy was performed on 30 synthetic metatarsal models using three fixation techniques. Specimens in group I were fixated with K-wires (1.6 mm × 2) and in group II with headless cannulated screws (3.0 mm × 2) distally through the intramedullary canal. Specimens in group III were fixated with a locking X-shaped plate (1.3-mm thick) and screws (2.5 mm × 4). Eight metatarsal specimens were selected from each group for walking fatigue test. Bending stiffness and dorsal angulation were measured by 1,000 repetitions of a cantilever bending protocol in a plantar to dorsal direction. The remaining two samples from each group were subjected to 5 mm per minute axial loading to assess the maximal loading tolerance. Results All samples in group I failed walking fatigue test while group II and group III tolerated the walking fatigue test. Group II showed greater resistance to bending force and smaller dorsal angulation than group III (p = 0.001). On the axial loading test, group I and group II demonstrated superior maximum tolerance to group III (54.8 N vs. 47.2 N vs. 28.3 N). Conclusions Authors have demonstrated proximal chevron metatarsal osteotomy with intramedullary screw fixation provides superior biomechanical stability to locking plate and K-wire fixations. The new technique using intramedullary screw fixation can offer robust fixation and may lead to better outcomes in surgical treatment of hallux valgus. PMID:29201305
Fracture toughness of brittle materials determined with chevron notch specimens
NASA Technical Reports Server (NTRS)
Shannon, J. L., Jr.; Bubsey, R. T.; Pierce, W. S.; Munz, D.
1981-01-01
Short bar, short rod, and four-point-bend chevron-notch specimens were used to determine the plane strain fracture toughness of hot-pressed silicon nitride and sintered aluminum oxide brittle ceramics. The unique advantages of this specimen type are: (1) the production of a sharp natural crack during the early stage of test loading, so that no precracking is required, and (2) the load passes through a maximum at a constant, material-independent crack length-to-width ratio for a specific geometry, so that no post-test crack measurement is required. The plane strain fracture toughness is proportional to the maximum test load and functions of the specimen geometry and elastic compliance. Although results obtained for silicon nitride are in good mutual agreement and relatively free of geometry and size effects, aluminum oxide results were affected in both these respects by the rising crack growth resistance curve of the material.
Motor System Upgrades Smooth the Way to Savings of $700,000 at Chevron Refinery
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1999-01-01
By upgrading its motor systems at its Richmond, California refinery, Chevron was able to realize cost savings of more than $700,000 per year, in addition to reduced energy consumption of approximately 1 million kilowatts per month and improved equipment reliability and process control. This fact sheet tells how they did it.
The results of gas permeability and leak testing during active soil-gas sampling at Hal’s Chevron LUST Site in Green River, Utah are presented. This study was conducted to support development of a passive soil-gas sampling method. Gas mixtures containing helium and methane were...
-overlay a{z-index:100;display:block;width:49%;height:100%;padding-top:45%;font-size:30px;color:#fff;text -nav-overlay a:empty{width:49%}.ekko-lightbox a:hover{text-decoration:none;opacity:1}.ekko-lightbox .glyphicon-chevron-left{left:0;float:left;padding-left:15px;text-align:left}.ekko-lightbox .glyphicon-chevron
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-05
... right-of-way (ROW) authorization to construct and operate a 45-megawatt solar photovoltaic project and... Energy Solutions Lucerne Valley Solar Project, San Bernardino County, CA, and the Draft California Desert... Statement (EIS) for the proposed Chevron Energy Solutions Lucerne Valley Solar Project and by this notice is...
%}.weather-widget .wx-cond{margin-top:0;font-size:90%}.carousel-control{opacity:1;z-index:100;width:5%;top:0 :0 .25em}.carousel-control .glyphicon-chevron-left,.carousel-control .glyphicon-chevron-right ,.carousel-control .icon-next,.carousel-control .icon-prev{top:40%}h4.date{font-size:1.3em;color:#000;font
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wereszczak, Andrew; Jadaan, Osama; Modugno, Max
In this paper, the apparent fracture toughness of a porous cordierite ceramic was estimated using a large specimen whose geometry was inspired by the ASTM-C1421-standardized chevron-notch beam. In this paper, using the same combination of experiment and analysis used to develop the standardized chevron-notch test for small, monolithic ceramic bend bars, an apparent fracture toughness of 0.6 and 0.9 MPa√m were estimated for an unaged and aged cordierite diesel particulate filter structure, respectively. Finally, the effectiveness and simplicity of this adapted specimen geometry and test method lends itself to the evaluation of (macroscopic) apparent fracture toughness of an entire porous-ceramic,more » diesel particulate filter structure.« less
Wereszczak, Andrew; Jadaan, Osama; Modugno, Max; ...
2017-01-18
In this paper, the apparent fracture toughness of a porous cordierite ceramic was estimated using a large specimen whose geometry was inspired by the ASTM-C1421-standardized chevron-notch beam. In this paper, using the same combination of experiment and analysis used to develop the standardized chevron-notch test for small, monolithic ceramic bend bars, an apparent fracture toughness of 0.6 and 0.9 MPa√m were estimated for an unaged and aged cordierite diesel particulate filter structure, respectively. Finally, the effectiveness and simplicity of this adapted specimen geometry and test method lends itself to the evaluation of (macroscopic) apparent fracture toughness of an entire porous-ceramic,more » diesel particulate filter structure.« less
NASA Technical Reports Server (NTRS)
Podboy, Gary G.; Bridges, James E.; Henderson, Brenda S.
2010-01-01
A 48-microphone planar phased array system was used to acquire jet noise source localization data on both a full-scale F404-GE-F400 engine and on a 1/4th scale model of a F400 series nozzle. The full-scale engine test data show the location of the dominant noise sources in the jet plume as a function of frequency for the engine in both baseline (no chevron) and chevron configurations. Data are presented for the engine operating both with and without afterburners. Based on lessons learned during this test, a set of recommendations are provided regarding how the phased array measurement system could be modified in order to obtain more useful acoustic source localization data on high-performance military engines in the future. The data obtained on the 1/4th scale F400 series nozzle provide useful insights regarding the full-scale engine jet noise source mechanisms, and document some of the differences associated with testing at model-scale versus fullscale.
Development of a Jet Noise Prediction Method for Installed Jet Configurations
NASA Technical Reports Server (NTRS)
Hunter, Craig A.; Thomas, Russell H.
2003-01-01
This paper describes development of the Jet3D noise prediction method and its application to heated jets with complex three-dimensional flow fields and installation effects. Noise predictions were made for four separate flow bypass ratio five nozzle configurations tested in the NASA Langley Jet Noise Laboratory. These configurations consist of a round core and fan nozzle with and without pylon, and an eight chevron core nozzle and round fan nozzle with and without pylon. Predicted SPL data were in good agreement with experimental noise measurements up to 121 inlet angle, beyond which Jet3D under predicted low frequency levels. This is due to inherent limitations in the formulation of Lighthill's Acoustic Analogy used in Jet3D, and will be corrected in ongoing development. Jet3D did an excellent job predicting full scale EPNL for nonchevron configurations, and captured the effect of the pylon, correctly predicting a reduction in EPNL. EPNL predictions for chevron configurations were not in good agreement with measured data, likely due to the lower mixing and longer potential cores in the CFD simulations of these cases.
NASA Astrophysics Data System (ADS)
Kuo, Ching-Wen
2010-06-01
Modern military aircraft jet engines are designed with variable geometry nozzles to provide optimum thrust in different operating conditions within the flight envelope. However, the acoustic measurements for such nozzles are scarce, due to the cost involved in making full-scale measurements and the lack of details about the exact geometry of these nozzles. Thus the present effort at The Pennsylvania State University and the NASA Glenn Research Center, in partnership with GE Aviation, is aiming to study and characterize the acoustic field produced by supersonic jets issuing from converging-diverging military style nozzles. An equally important objective is to develop a scaling methodology for using data obtained from small- and moderate-scale experiments which exhibits the independence of the jet sizes to the measured noise levels. The experimental results presented in this thesis have shown reasonable agreement between small-scale and moderate-scale jet acoustic data, as well as between heated jets and heat-simulated ones. As the scaling methodology is validated, it will be extended to using acoustic data measured with small-scale supersonic model jets to the prediction of the most important components of full-scale engine noise. When comparing the measured acoustic spectra with a microphone array set at different radial locations, the characteristics of the jet noise source distribution may induce subtle inaccuracies, depending on the conditions of jet operation. A close look is taken at the details of the noise generation region in order to better understand the mismatch between spectra measured at various acoustic field radial locations. A processing methodology was developed to correct the effect of the noise source distribution and efficiently compare near-field and far-field spectra with unprecedented accuracy. This technique then demonstrates that the measured noise levels in the physically restricted space of an anechoic chamber can be appropriately extrapolated to represent the expected noise levels at different noise monitoring locations of practical interest. With the emergence of more powerful fighter aircraft, supersonic jet noise reduction devices are being intensely researched. Small-scale measurements are a crucial step in evaluating the potential of noise reduction concepts at an early stage in the design process. With this in mind, the present thesis provides an acoustic assessment methodology for small-scale military-style nozzles with chevrons. Comparisons are made between the present measurements and those made by NASA at moderate-scale. The effect of chevrons on supersonic jets was investigated, highlighting the crucial role of the jet operating conditions on the effects of chevrons on the jet flow and the subsequent acoustic benefits. A small-scale heat simulated jet is investigated in the over-expanded condition and shows no substantial noise reduction from the chevrons. This is contrary to moderate-scale measurements. The discrepancy is attributed to a Reynolds number low enough to sustain an annular laminar boundary layer in the nozzle that separates in the over-expanded flow condition. These results are important in assessing the limitations of small-scale measurements in this particular jet noise reduction method. Lastly, to successfully present the results from the acoustic measurements of small-scale jets with high quality, a newly developed PSU free-field response was empirically derived to match the specific orientation and grid cap geometry of the microphones. Application to measured data gives encouraging results validating the capability of the method to produce superior accuracy in measurements even at the highest response frequencies of the microphones.
Trost, Matthias; Bredow, Jan; Boese, Christoph Kolja; Loweg, Lennard; Schulte, Tobias Ludger; Scaal, Martin; Eysel, Peer; Oppermann, Johannes
Distal chevron osteotomy is a common procedure for surgical correction of hallux valgus. Osteosynthesis with 1 screw or 2 Kirschner wires has been commonly used. We compared the stability of the 2 techniques in distal chevron osteotomy. Sixteen first metatarsals from fresh-frozen human cadaver feet (9 different cadaveric specimens) were used. A standardized distal chevron osteotomy was performed. One first metatarsal from each pair was assigned to group 1 (3.5-mm cortical screw; n = 8) and one to group 2 (two 1.6-mm Kirschner wires; n = 8). Using a materials testing machine, the head of the first metatarsals was loaded in 2 different configurations (cantilever and physiologic) in succession. In the cantilever configuration, the relative stiffness of the osteosynthesis compared with intact bone was 59% ± 27% in group 1 and 68% ± 18% in group 2 (p = .50). In the physiologic configuration, it was 38% ± 25% in group 1 and 35% ± 7% in group 2 (p = .75). The failure strength in the cantilever configuration was 187 ± 105 N in group 1 and 259 ± 71 N in group 2 (p = .21). No statistically significant differences were found in stability between the 2 techniques. The use of 1 screw or 2 Kirschner wires had no significant differences in their biomechanical loading capacity for osteosynthesis in distal chevron osteotomies for treatment of hallux valgus. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Outcomes of proximal chevron osteotomy for moderate versus severe hallux valgus deformities.
Moon, Jae-Young; Lee, Keun-Bae; Seon, Jong Keun; Moon, Eun-Sun; Jung, Sung-Taek
2012-08-01
Proximal chevron osteotomy with a distal soft tissue procedure has been widely used to treat moderate to severe hallux valgus deformities. However, there have been no studies comparing the results of proximal chevron osteotomy between patients with moderate and severe hallux valgus. We compared the results of this procedure among these groups. A retrospective review of 95 patients (108 feet) that underwent proximal chevron osteotomy and distal soft tissue procedure for moderate and severe hallux valgus was conducted. The 108 feet were divided into two groups: moderate hallux valgus (Group A) and severe hallux valgus (Group B). Group A was composed of 57 feet (52 patients) and Group B of 51 feet (43 patients). Average followup was 45 months. Mean American Orthopedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal scores were 54.1 points in Group A and 53.0 points in Group B preoperatively, and these improved to 90.8 and 92.6, respectively, at the last followup. Mean hallux valgus angles in Groups A and B reduced from 32.3 and 40.8 degrees, preoperatively to 10.7 and 13.2 degrees, postoperatively. Similarly, mean first intermetatarsal angles in Groups A and B reduced from 15.0 and 19.2 degrees, preoperatively to 9.0 and 9.2 degrees, postoperatively. The clinical and radiographic outcomes of proximal chevron osteotomy with a distal soft tissue procedure were found to be comparable for moderate and severe hallux valgus. Accordingly, our results suggest that this procedure provides an effective and reliable means of correcting hallux valgus regardless of severity of deformity.
Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi
2017-02-01
The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.
Analytical and computational studies on the vacuum performance of a chevron ejector
NASA Astrophysics Data System (ADS)
Kong, F. S.; Jin, Y. Z.; Kim, H. D.
2016-11-01
The effects of chevrons on the performance of a supersonic vacuum ejector-diffuser system are investigated numerically and evaluated theoretically in this work. A three-dimensional geometrical domain is numerically solved using a fully implicit finite volume scheme based on the unsteady Reynolds stress model. A one-dimensional mathematical model provides a useful tool to reveal the steady flow physics inside the vacuum ejector-diffuser system. The effects of the chevron nozzle on the generation of recirculation regions and Reynolds stress behaviors are studied and compared with those of a conventional convergent nozzle. The present performance parameters obtained from the simulated results and the mathematical results are validated with existing experimental data and show good agreement. Primary results show that the duration of the transient period and the secondary chamber pressure at a dynamic equilibrium state depend strongly on the primary jet conditions, such as inlet pressure and primary nozzle shape. Complicated oscillatory flow, generated by the unsteady movement of recirculation, finally settles into a dynamic equilibrium state. As a vortex generator, the chevron demonstrated its strong entrainment capacity to accelerate the starting transient flows to a certain extent and reduce the dynamic equilibrium pressure of the secondary chamber significantly.
Chevron folding patterns and heteroclinic orbits
NASA Astrophysics Data System (ADS)
Budd, Christopher J.; Chakhchoukh, Amine N.; Dodwell, Timothy J.; Kuske, Rachel
2016-09-01
We present a model of multilayer folding in which layers with bending stiffness EI are separated by a very stiff elastic medium of elasticity k2 and subject to a horizontal load P. By using a dynamical system analysis of the resulting fourth order equation, we show that as the end shortening per unit length E is increased, then if k2 is large there is a smooth transition from small amplitude sinusoidal solutions at moderate values of P to larger amplitude chevron folds, with straight limbs separated by regions of high curvature when P is large. The chevron solutions take the form of near heteroclinic connections in the phase-plane. By means of this analysis, values for P and the slope of the limbs are calculated in terms of E and k2.
NASA Technical Reports Server (NTRS)
1986-01-01
This image of Miranda, obtained by Voyager 2 on approach, shows an unusual 'chevron' figure and regions of distinctly differing terrain on the Uranian moon. Voyager was 42,000 kilometers (26,000 miles) away when its narrow-angle camera acquired this clear-filter view. Grooved areas baring light and dark bands, distinct from other areas of mottled terrain, are visible at this resolution of about 600 meters (2,000 feet). The bright V-shaped feature in the grooved areas is the 'chevron' observed in earlier, lower-resolution images. Cutting across the bands are sinuous scarps, probably faults. Superimposed on both types of terrain are many bowl-shaped impact craters less than 5 km (3 mi) wide. The entire picture spans an area about 220 km (140 mi) across. The Voyager project is managed for NASA by the Jet Propulsion Laboratory.
Lee, Jun Young; Lee, Yeon Soo; Song, Kyoung Chul; Choi, Kwi Youn
2015-01-01
The present study assessed the changes in the length of the first metatarsal bone after performing proximal chevron metatarsal osteotomy (PCMO) or distal Chevron metatarsal osteotomy (DCMO) for patients with hallux valgus deformity. A total of 60 patients with moderate-to-severe hallux valgus deformity from July 2009 to July 2011 were randomly divided into the PCMO and DCMO groups, with 30 patients in each group. The distal soft tissue procedure was performed in the same method for both groups. Measurements were performed preoperatively, postoperatively, and at the last follow-up visit at 6.1 ± 0.8 months. The postoperative length change with respect to the preoperative length was 0.7 ± 2.5 mm and -0.7 ± 5.1 mm for the PCMO and DCMO groups, respectively, with a slight lengthening of the first metatarsal bone in the PCMO group and a shortening in the DCMO group (p < .01). The follow-up length change with respect to the preoperative length was -2.1 ± 3.0 mm and -4.4 ± 2.2 mm for the PCMO and DCMO groups, respectively, demonstrating a clear shortening of the first metatarsal length at the last follow-up point in the DCMO group (p < .01).When DCMO and the distal soft tissue procedure were performed, significant shortening was found at 6 months of follow-up. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Crack resistance determination of material by wedge splitting a chevron-notched specimen
NASA Astrophysics Data System (ADS)
Deryugin, Ye. Ye.
2017-12-01
An original method is proposed for the crack resistance determination of a material by wedge splitting of a chevron-notched specimen. It was developed at the Institute of Strength Physics and Materials Science SB RAS in the laboratory of Physical Mesomechanics and Nondestructive Methods of Control. An example of the crack resistance test of technical titanium VT1-0 is considered.
Chevron osteotomy with lateral release and adductor tenotomy for hallux valgus.
Potenza, Vito; Caterini, Roberto; Farsetti, Pasquale; Forconi, Fabrizio; Savarese, Eugenio; Nicoletti, Simone; Ippolito, Ernesto
2009-06-01
Distal chevron osteotomy is a procedure widely performed for the surgical treatment of painful hallux valgus. The risks and benefits of a lateral capsular release and adductor tenotomy combined with chevron osteotomy are still debated. The aim of our study was to report the clinical and radiographic outcomes of this combined procedure in mild and moderate incongruent bunion deformities, with a hallux valgus angle (HVA) up to 40 degrees and an intermetatarsal angle (IMA) up to 20 degrees. Forty-two patients (52 feet) who consecutively underwent chevron osteotomy combined with lateral release and adductor tenotomy were reviewed 24-36 months after surgery. The mean age of the patients was 53.5 (range, 43 to 64) years. All the deformities were mild to moderate, with a mean preoperative value of 28 degrees in the HVA (range, 16 degrees to 40 degrees) and of 13 degrees in the IMA (range, 9 degrees to 20 degrees). At followup, the AOFAS hallux score improved from an average of 46 to an average of 88. The HVA and IMA had an average postoperative decrease respectively of 12 degrees and 6 degrees; lateral sesamoid displacement decreased by a mean of 15%. In no case did we observe infection or nonunion of the osteotomy. In one case, painless avascular necrosis of the first metatarsal head developed. Our short-term results show that distal chevron osteotomy combined with lateral release and adductor tenotomy is a feasible surgical option to address mild to moderate hallux valgus deformity, even with an IM angle between 15 and 20 degrees. Clinical and radiographic outcomes are generally good and patient satisfaction is generally high.
Kim, Hyong-Nyun; Suh, Dong-Hyun; Hwang, Pil-Sung; Yu, Sun-O; Park, Yong-Wook
2011-04-01
The purpose of this study was to evaluate the clinical results of distal chevron osteotomy performed in conjunction with selective lateral soft tissue release. The criterion for doing a lateral soft tissue release was assessed by determining the ease and completeness of passive hallux valgus correction at the time of surgery. Between August 2005 and November 2007, 48 feet in 43 patients classified as having mild to moderate hallux valgus were retrospectively studied. Distal chevron osteotomy without lateral soft tissue release was performed in 26 cases (Group 1) when passive correction of the hallux valgus deformity was possible. Distal chevron osteotomy with lateral soft tissue release was performed in 22 cases (Group 2) when passive correction was not possible. Average followup was 23 (range, 12 to 28) months. Clinical results were assessed using radiographic parameters [hallux valgus angle (HVA), first and second intermetatarsal angle (1,2 IMA)], AOFAS scale and patient's subjective satisfaction. For Group 1: the average correction of HVA was 12.8 degrees, the average correction of IMA was 4.7 degrees, and the AOFAS score improved an average of 29.2 points at the last followup. Thirteen patients were very satisfied and ten patients were satisfied with the results. No patient was dissatisfied. For Group 2: the average correction of HVA was 19.1 degrees, the average correction of IMA was 7 degrees and AOFAS score improved at an average of 31.8 points at the last followup. Twelve patients were very satisfied, seven patients were satisfied and one patient, who had stiffness of the first metatarsophalangeal joint, was dissatisfied with the result. Distal chevron osteotomy with selective lateral soft tissue release based on the ability to passively correct the hallux valgus deformity lead to safe and stable correction.
Holocene Indian Ocean Cosmic Impacts: The Megatsunami Chevron Evidence From Madagascar
NASA Astrophysics Data System (ADS)
Masse, W.; Bryant, E.; Gusiakov, V.; Abbott, D.; Rambolamana, G.; Raza, H.; Courty, M.; Breger, D.; Gerard-Little, P.; Burckle, L.
2006-12-01
The 2.6 million year Quaternary period terrestrial physical record lacks definitive crater evidence for major regional catastrophic impacts by asteroids and comets other than the 10.5-km diameter Botsumtwi structure in Ghana and the 14.0-km diameter Zhamanshin structure in Kazakhstan [1] dating between about 900 and 1100 kya. Current cosmic impact rate models suggest that an average of between 3-6 globally catastrophic impacts should have occurred on the Earth during the Quaternary, along with several additional significant regional impacts in addition to Zhamanshin and Botsumtwi. These models and data indicate that the great majority of the "missing" major impact locations would likely have occurred in poorly studied oceanic settings. Only recently have Late Quaternary and Holocene period coastal paleo-megatsunami chevron deposits been defined in the Caribbean and along the western coasts of Australia, along with the suggestion that some may have been created by oceanic cosmic impacts in distinction to those caused by landslips, eruptions, and seismic events. We investigate the possibility that many or most megatsunami chevrons occurring along the southern coast of Madagascar were caused by two or more major Holocene Indian Ocean cosmic impacts. This hypothesis is based on an initial study of the worldwide archaeological and anthropological record, and the preliminary study of satellite images of the chevrons, selected Indian Ocean deep-sea cores, sea-floor bathymetry, and physical examination of the Madagascar deposits themselves. Candidate Indian Ocean impact structures are identified and correlated with the southern Madagascar megatsunami chevron deposits. [1] Masse, W.B. 2007 The Archaeology and Anthropology of Quaternary Period Cosmic Impact. In Bobrowsky, P.T. & Rickman, H. (eds.)Comets/Asteroid Impacts and Human Society. Springer, Berlin (in press).
Longitudinal Variation and Waves in Jupiter's South Equatorial Wind Jet
NASA Technical Reports Server (NTRS)
Simon-Miller, Amy A.; Choi, David; Rogers, John H.; Gierasch, Peter J.; Allison, Michael D.; Adamoli, Gianluigi; Mettig, Hans-Joerg
2012-01-01
A detailed study of the chevron-shaped dark spots on the strong southern equatorial wind jet near 7.5 S planetographic latitude shows variations in velocity with longitude and time. The presence of the large anticyclonic South Equatorial Disturbance (SED) has a profound effect on the chevron velocity, causing slower velocities to its east and accelerations over distance from the disturbance. The chevrons move with velocities near the maximum wind jet velocity of approx 140 m/s, as deduced by the history of velocities at this latitude and the magnitude of the symmetric wind jet near 7 N latitude. Their repetitive nature is consistent with a gravity-inertia wave (n = 75 to 100) with phase speed up to 25 m/s, relative to the local flow, but the identity of this wave mode is not well constrained. However, for the first time, high spatial resolution movies from Cassini images show that the chevrons oscillate in latitude with a 6.7 +/- 0.7-day period. This oscillating motion has a wavelength of approx 20 and a speed of 101 +/- 3 m/s, following a pattern similar to that seen in the Rossby wave plumes of the North Equatorial Zone, and possibly reinforced by it. All dates show chevron latitude variability, but it is unclear if this larger wave is present during other epochs, as there are no other suitable time series movies that fully delineate it. In the presence of mUltiple wave modes, the difference in dominant cloud appearance between 7 deg N and 7.5 deg S is likely due to the presence of the Great Red Spot, either through changes in stratification and stability or by acting as a wave boundary.
NASA Technical Reports Server (NTRS)
Chao, L. Y.; Singh, D.; Shetty, D. K.
1988-01-01
A numerical computational study was carried out to assess the effects of subcritical crack growth on crack stability in the chevron-notched three-point bend specimens. A power-law relationship between the subcritical crack velocity and the applied stress intensity were used along with compliance and stress-intensity relationships for the chevron-notched bend specimen to calculate the load response under fixed deflection rate and a machine compliance. The results indicate that the maximum load during the test occurs at the same crack length for all the deflection rates; the maximum load, however, is dependent on the deflection rate for rates below the critical rate. The resulting dependence of the apparent fracture toughness on the deflection rate is compared to experimental results on soda-lime glass and polycrystalline alumina.
Resistive anode image converter
NASA Technical Reports Server (NTRS)
Lampton, M. L.; Paresce, F. (Inventor)
1976-01-01
The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.
Seismic data compression speeds exploration projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galibert, P.Y.
As part of an ongoing commitment to ensure industry-wide distribution of its revolutionary seismic data compression technology, Chevron Petroleum Technology Co. (CPTC) has entered into licensing agreements with Compagnie Generale de Geophysique (CGG) and other seismic contractors for use of its software in oil and gas exploration programs. CPTC expects use of the technology to be far-reaching to all of its industry partners involved in seismic data collection, processing, analysis and storage. Here, CGG--one of the world`s leading seismic acquisition and processing companies--talks about its success in applying the new methodology to replace full on-board seismic processing. Chevron`s technology ismore » already being applied on large off-shore 3-D seismic surveys. Worldwide, CGG has acquired more than 80,000 km of seismic data using the data compression technology.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muley, A.; Manglik, R.M.
1997-07-01
Experimental data for isothermal pressure drop and heat transfer in single-phase water flows in a plate heat exchanger (PHE) with chevron plates are presented. A single-pass, U-type, counterflow PHE, with three different chevron plate arrangements is employed: two symmetric plate arrangements with {beta} = 30/30{degree} and 60/60{degree}, and a mixed-plate arrangement with {beta} = 30/60{degree}. With water flow rates in the turbulent flow regime (600 < Re < 10{sup 4} and 2 < Pr < 6), effects of the chevron corrugation inclination angle {beta} on Nu and f characteristics of the PHE are investigated. As {beta} increases and compared tomore » a flat-plate pack, up to 2 to 5 times higher Nu are obtained; the concomitant f, however, are 13 to 44 times higher. Based on the experimental data for Re {le} 1,000, predictive correlations of the form Nu = C{sub 1}{beta} Re{sup p1({beta})} Pr{sup 1/3} ({mu}/{mu}{sub w}){sup 0.14} and f = C{sub 2}{beta} Re{sup p2({beta})} are devised. Also, at constant pumping power and depending upon {beta}, the heat transfer is found to be enhanced over 1.8 times that in equivalent flat-plate channels.« less
Two genetic loci control syllable sequences of ultrasonic courtship vocalizations in inbred mice
2011-01-01
Background The ultrasonic vocalizations (USV) of courting male mice are known to possess a phonetic structure with a complex combination of several syllables. The genetic mechanisms underlying the syllable sequence organization were investigated. Results This study compared syllable sequence organization in two inbred strains of mice, 129S4/SvJae (129) and C57BL6J (B6), and demonstrated that they possessed two mutually exclusive phenotypes. The 129S4/SvJae (129) strain frequently exhibited a "chevron-wave" USV pattern, which was characterized by the repetition of chevron-type syllables. The C57BL/6J strain produced a "staccato" USV pattern, which was characterized by the repetition of short-type syllables. An F1 strain obtained by crossing the 129S4/SvJae and C57BL/6J strains produced only the staccato phenotype. The chevron-wave and staccato phenotypes reappeared in the F2 generations, following the Mendelian law of independent assortment. Conclusions These results suggest that two genetic loci control the organization of syllable sequences. These loci were occupied by the staccato and chevron-wave alleles in the B6 and 129 mouse strains, respectively. Recombination of these alleles might lead to the diversity of USV patterns produced by mice. PMID:22018021
Park, C-H; Jang, J-H; Lee, S-H; Lee, W-C
2013-05-01
The purpose of this study was to compare the results of proximal and distal chevron osteotomy in patients with moderate hallux valgus. We retrospectively reviewed 34 proximal chevron osteotomies without lateral release (PCO group) and 33 distal chevron osteotomies (DCO group) performed sequentially by a single surgeon. There were no differences between the groups with regard to age, length of follow-up, demographic or radiological parameters. The clinical results were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring system and the radiological results were compared between the groups. At a mean follow-up of 14.6 months (14 to 32) there were no significant differences in the mean AOFAS scores between the DCO and PCO groups (93.9 (82 to 100) and 91.8 (77 to 100), respectively; p = 0.176). The mean hallux valgus angle, intermetatarsal angle and sesamoid position were the same in both groups. The metatarsal declination angle decreased significantly in the PCO group (p = 0.005) and the mean shortening of the first metatarsal was significantly greater in the DCO group (p < 0.001). We conclude that the clinical and radiological outcome after a DCO is comparable with that after a PCO; longer follow-up would be needed to assess the risk of avascular necrosis.
NASA Technical Reports Server (NTRS)
Low, John K. C.; Schweiger, Paul S.; Premo, John W.; Barber, Thomas J.; Saiyed, Naseem (Technical Monitor)
2000-01-01
NASA s model-scale nozzle noise tests show that it is possible to achieve a 3 EPNdB jet noise reduction with inwardfacing chevrons and flipper-tabs installed on the primary nozzle and fan nozzle chevrons. These chevrons and tabs are simple devices and are easy to be incorporated into existing short duct separate-flow nonmixed nozzle exhaust systems. However, these devices are expected to cause some small amount of thrust loss relative to the axisymmetric baseline nozzle system. Thus, it is important to have these devices further tested in a calibrated nozzle performance test facility to quantify the thrust performances of these devices. The choice of chevrons or tabs for jet noise suppression would most likely be based on the results of thrust loss performance tests to be conducted by Aero System Engineering (ASE) Inc. It is anticipated that the most promising concepts identified from this program will be validated in full scale engine tests at both Pratt & Whitney and Allied-Signal, under funding from NASA s Engine Validation of Noise Reduction Concepts (EVNRC) programs. This will bring the technology readiness level to the point where the jet noise suppression concepts could be incorporated with high confidence into either new or existing turbofan engines having short-duct, separate-flow nacelles.
NASA Technical Reports Server (NTRS)
George, P. K.; Oeffinger, T. R.; Chen, T. T.
1976-01-01
Experiments were devised to study the angular variation of the resistance and noise properties of one- and two-level chevron stretcher magnetoresistive detectors for use in field access bubble memory devices. All measurements, made with an electronic system, were performed on glass or garnet samples upon which 1 micron of SiO2 was sputter-deposited, followed by 4000 A of Permalloy for the 28-micron-period devices and 0.8 microns of SiO2, followed by 3000 A of Permalloy for the 20-micron-period devices. The geometrical and drive-state dependence of the zero-state noise were studied, as was its frequency dependence. It is found that both types of detectors operate primarily in the amplitude-shift mode for drive fields of interest and that the presence of a bubble in a detector causes a magnetoresistance change equal to that produced by increasing the in-plane drive field about 8 Oe in the absence of a bubble.
Density Fluctuation in Asymmetric Nozzle Plumes and Correlation with Far Field Noise
NASA Technical Reports Server (NTRS)
Panda, J.; Zaman, K. B. M. Q.
2001-01-01
A comparative experimental study of air density fluctuations in the unheated plumes of a circular, 4-tabbed-circular, chevron-circular and 10-lobed rectangular nozzles was performed at a fixed Mach number of 0.95 using a recently developed Rayleigh scattering based technique. Subsequently, the flow density fluctuations are cross-correlated with the far field sound pressure fluctuations to determine sources for acoustics emission. The nearly identical noise spectra from the baseline circular and the chevron nozzles are found to be in agreement with the similarity in spreading, turbulence fluctuations, and flow-sound correlations measured in the plumes. The lobed nozzle produced the least low frequency noise, in agreement with the weakest overall density fluctuations and flow-sound correlation. The tabbed nozzle took an intermediate position in the hierarchy of noise generation, intensity of turbulent fluctuation and flow-sound correlation. Some of the features in the 4-tabbed nozzle are found to be explainable in terms of splitting of the jet in a central large core and 4 side jetlets.
Feng, S M; Wang, A G; Ding, P; Zhang, Z Y; Zhou, M M; Li, C K; Sun, Q Q
2016-07-26
To explore the surgical method of using the modified chevron osteotomy combined distal soft tissue reconstruction to treat high-grade bunionette deformity. From June 2013 to June 2015, the modified chevron osteotomy combined distal soft tissue reconstruction was used for surgical treatment of high-grade bunionette deformity in the Department of Hand and Foot Microsurgery in Xuzhou Central Hospital.Twenty-six patients with 28 feet high-grade bunionette deformity were hospitalized for treatment, with 3 male (3 feet) and 23 female (25 feet) cases, aged 22-73 (mean 47.1) years old.The average fourth-fifth intermetatarsal angle, lateral deviation of the fifth metatarsal angle and metatarsophalangeal-fifth angle were measured on the pre-and post- operative anterior to posterior weight-beating X rays of treated feet.The American Orthopaedic Foot and Ankle Society (AOFAS) Lesser Toe Metatarsophalangeal-Interphalangeal Scale was used to evaluate the post-operative outcomes. All of 26 patients were followed, with a mean 15.7 months (range 8-25 months). Primarily healing of the wound was achieved in all cases.No postoperative infection and nonunion on the osteotomy site was found during the follow-up time.The fracture healing time was 6-15 (mean 12.2) weeks.All the patients had satisfactory appearance and sensory function without callosum and metastatic metatarsalgia at the final follow-up.The post-operative fourth-fifth intermetatarsal angle, lateral deviation of the fifth metatarsal angle and metatarsophalangeal-fifth angle were significantly lesser than the pre-operative at the 6th week after operation, respectively [(5.5±1.7)°, (2.1±0.8)°, (5.7±2.6)°vs (16.4±4.2)°, (6.0±2.2)°, (10.5±7.4)°; all P<0.01]. The post-operative AOFAS score was significantly greater than the pre-operative [(87.1±6.7) vs (62.3±9.8) points, P<0.001]. The modified chevron osteotomy combined distal soft tissue reconstruction is a safe and easy treatment option for the high-grade bunionette deformity and provides patient satisfaction results.
NASA Astrophysics Data System (ADS)
Xu, Yuan; Dai, Feng; Zhao, Tao; Xu, Nu-wen; Liu, Yi
2016-08-01
The cracked chevron notched Brazilian disc (CCNBD) specimen has been suggested by the International Society for Rock Mechanics to measure the mode I fracture toughness of rocks, and has been widely adopted in laboratory tests. Nevertheless, a certain discrepancy has been observed in results when compared with those derived from methods using straight through cracked specimens, which might be due to the fact that the fracture profiles of rock specimens cannot match the straight through crack front as assumed in the measuring principle. In this study, the progressive fracturing of the CCNBD specimen is numerically investigated using the discrete element method (DEM), aiming to evaluate the impact of the realistic cracking profiles on the mode I fracture toughness measurements. The obtained results validate the curved fracture fronts throughout the fracture process, as reported in the literature. The fracture toughness is subsequently determined via the proposed G-method originated from Griffith's energy theory, in which the evolution of the realistic fracture profile as well as the accumulated fracture energy is quantified by DEM simulation. A comparison between the numerical tests and the experimental results derived from both the CCNBD and the semi-circular bend (SCB) specimens verifies that the G-method incorporating realistic fracture profiles can contribute to narrowing down the gap between the fracture toughness values measured via the CCNBD and the SCB method.
Electronic characterization of silicon intercalated chevron graphene nanoribbons on Au(111).
Deniz, O; Sánchez-Sánchez, C; Jaafar, R; Kharche, N; Liang, L; Meunier, V; Feng, X; Müllen, K; Fasel, R; Ruffieux, P
2018-02-08
Electronic and thermal properties of chevron-type graphene nanoribbons can be widely tuned, making them interesting candidates for electronic and thermoelectric applications. Here, we use post-growth silicon intercalation to unambiguously access nanoribbons' energy position of their electronic frontier states. These are otherwise obscured by substrate effects when investigated directly on the growth substrate. In agreement with first-principles calculations we find a band gap of 2.4 eV.
Thermal-hydraulic behavior of a mixed chevron single-pass plate-and-frame heat exchanger
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manglik, R.M.; Muley, A.
1995-12-31
Effective heat exchange is very critical for improving the process efficiency and operating economy of chemical and process plants. Here, experimental friction factor and heat transfer data for single-phase water flows in a plate-and-frame heat exchanger are presented. A mixed chevron plate arrangement with {beta} = 30{degree}/60{degree} in a single-pass U-type, counterflow configuration is employed. The friction factor and heat transfer data are for isothermal flow and cooling conditions, respectively, and the flow rates correspond to transition and turbulent flow regimes (300 < Re < 6,000 and 2.4 < Pr < 4.5). Based on these data, Nusselt number and frictionmore » factor correlations for fully developed turbulent flows (Re {ge} 1,000) are presented. The results highlight the effects of {beta} on the thermal-hydraulic performance, transition to turbulent flows, and the relative impact of using symmetric or mixed chevron plate arrangements.« less
Investigations on the performance of chevron type plate heat exchangers
NASA Astrophysics Data System (ADS)
Dutta, Oruganti Yaga; Nageswara Rao, B.
2018-01-01
This paper presents empirical relations for the chevron type plate heat exchangers (PHEs) and demonstrated their validity through comparison of test data of PHEs. In order to examine the performance of PHEs, the pressure drop(Δ P), the overall heat transfer coefficient ( U m ) and the effectiveness ( ɛ) are estimated by considering the properties of plate material and working fluid, number of plates ( N t ) and chevron angle( β). It is a known fact that, large surface area of the plate provides more rate of heat transfer ( \\dot{Q} ) thereby more effectiveness ( ɛ). However, there is a possibility to achieve the required performance by increasing the number of plates without altering the plate dimensions, which avoids the new design of the system. Application of the Taguchi's design of experiments is examined with less number of experiments and demonstrated by setting the levels for the parameters and compared the test data with the estimated output responses.
Articles which include chevron film cooling holes, and related processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bunker, Ronald Scott; Lacy, Benjamin Paul
An article is described, including an inner surface which can be exposed to a first fluid; an inlet; and an outer surface spaced from the inner surface, which can be exposed to a hotter second fluid. The article further includes at least one row or other pattern of passage holes. Each passage hole includes an inlet bore extending through the substrate from the inlet at the inner surface to a passage hole-exit proximate to the outer surface, with the inlet bore terminating in a chevron outlet adjacent the hole-exit. The chevron outlet includes a pair of wing troughs having amore » common surface region between them. The common surface region includes a valley which is adjacent the hole-exit; and a plateau adjacent the valley. The article can be an airfoil. Related methods for preparing the passage holes are also described.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bent, Jimmy
2014-05-31
In 2000 Chevron began a project to learn how to characterize the natural gas hydrate deposits in the deep water portion of the Gulf of Mexico (GOM). Chevron is an active explorer and operator in the Gulf of Mexico and is aware that natural gas hydrates need to be understood to operate safely in deep water. In August 2000 Chevron worked closely with the National Energy Technology Laboratory (NETL) of the United States Department of Energy (DOE) and held a workshop in Houston, Texas to define issues concerning the characterization of natural gas hydrate deposits. Specifically, the workshop was meantmore » to clearly show where research, the development of new technologies, and new information sources would be of benefit to the DOE and to the oil and gas industry in defining issues and solving gas hydrate problems in deep water.« less
NASA Technical Reports Server (NTRS)
Doty, Michael J.; Henerson, Brenda S.; Kinzie, Kevin W.
2004-01-01
Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.
Electronic characterization of silicon intercalated chevron graphene nanoribbons on Au(111)
Deniz, O.; Sánchez-Sánchez, C.; Jaafar, R.; ...
2018-01-08
Electronic and thermal properties of chevron-type graphene nanoribbons can be widely tuned, making them interesting candidates for electronic and thermoelectric applications. In this paper, we use post-growth silicon intercalation to unambiguously access nanoribbons’ energy position of their electronic frontier states. These are otherwise obscured by substrate effects when investigated directly on the growth substrate. Finally, in agreement with first-principles calculations we find a band gap of 2.4 eV.
Lamb, Joshua; Murawski, Christopher D; Deyer, Timothy W; Kennedy, John G
2013-06-01
The purpose of this study was to retrospectively evaluate a large series of patients for functional, radiographic and MRI outcomes after a Chevron-type medial malleolar osteotomy. Sixty-two patients underwent a Chevron-type medial malleolar osteotomy with a median follow-up of 34.5 months. Standard digital radiographs were used to determine bony union and the angle of the osteotomy relative to the longitudinal axis of the tibia. Morphologic and quantitative T2-mapping MRI was also analysed in 32 patients. Fifty-eight patients (94 %) reported being asymptomatic at the site of the medial malleolar osteotomy. The median time to healing on standard radiograph was 6 weeks (range, 4-6 weeks) with an angle of 31.7° ± 6.9°. Quantitative T2-mapping MRI analysis demonstrated that the deep half of interface repair tissue had relaxation times that were not significantly different from normal tibial cartilage. In contrast, interface repair tissue in the superficial half demonstrated significant prolongation from normal relaxation time values, indicating a more fibrocartilaginous repair. Four patients (6 %) reported pain post-operatively. A Chevron-type medial malleolar osteotomy demonstrates satisfactory healing and fixation, with fibrocartilaginous tissue evident superficially at the osteotomy interface. Further investigation is warranted in the form of longitudinal study to assess the long-term outcomes of medial malleolar osteotomy.
Fakoor, Mohammad; Sarafan, Naser; Mohammadhoseini, Payam; Khorami, Mohsen; Arti, Hamidreza; Mosavi, SeyedShahnam; Aghaeeaghdam, Amir
2014-01-01
Background: Hallux valgus deformity is a common chronic problem with a reported prevalence of 28.4% and its chief complaint is pain. Thus far, different surgical procedures with their proposed indications have been introduced. This study compared three current procedures, namely the chevron and scarf osteotomies and the McBride procedure. Methods: This retrospective cohort was conducted at the Ahvaz University of Medical Sciences on 44 patients with moderate hallux valgus deformity from 2010 and 2013. All of the patients underwent one of the three procedures (chevron, scarf or McBride). Preoperative and follow up radiographies were evaluated in terms of hallux valgus and intermetatarsal angle correction. The Foot and Ankle Disability Index was filled out to assess the functional outcome and the Visual Analogue Scale was used to evaluate pain. Also, satisfaction, aesthetics and the rate of recurrence was evaluated. Results: Hallux valgus angle and intermetatarsal angle correction were significantly higher in scarf, but not in chevron and McBride. However, from amongst the three procedures, there was no significant difference in terms of the Foot and Ankle Disability Index score, aesthetics, satisfaction level, pain score and recurrence rate. Conclusions: Considering that scarf osteotomy had better results in this study, we think that scarf osteotomy can be considered as a first choice for the treatment of moderate hallux valgus deformity. PMID:25207310
Hallux valgus correction using transarticular lateral release with distal chevron osteotomy.
Choi, Young Rak; Lee, Ho Seong; Jeong, Jae Jung; Kim, Sang Woo; Jeon, In-Ho; Lee, Dong Ho; Lee, Woo Chun
2012-10-01
Transarticular lateral release through a medial incision can avoid a dorsal incision. This study investigated outcomes following hallux valgus correction using transarticular lateral release, distal chevron metatarsal osteotomy and Akin phalangeal osteotomy through one medial incision. Between June 2004 and May 2009, a single surgeon performed a transarticular lateral release, distal chevron metatarsal osteotomy and Akin phalangeal osteotomy through one medial incision for hallux valgus on a total of 103 feet of 68 patients. The average patient age at the time of surgery was 51 years, and the average followup was 27 months. The average preoperative and final followup results were: 1) hallux valgus angle improvement from 29 degrees to 5 degrees, 2) intermetatarsal angle from 13 degrees to 5 degrees and 3) medial sesamoid bone position from 3 to 1 (p < 0.05 for each variable). The average AOFAS scores were improved from 49 to 92, and the VAS pain scores were improved from 7 to 1 (p < 0.05 for both variables). No patient had a serious complication such as infection, avascular necrosis, nonunion, transfer-metatarsalgia, or first metatarsophalangeal joint arthritis. Hallux valgus correction using transarticular lateral release, distal chevron metatarsal osteotomy and Akin phalangeal osteotomy through one medial incision was found to be effective and safe. The advantages include that the procedure is simple, early ambulation is possible, and there is no dorsal scarring.
Fakoor, Mohammad; Sarafan, Naser; Mohammadhoseini, Payam; Khorami, Mohsen; Arti, Hamidreza; Mosavi, SeyedShahnam; Aghaeeaghdam, Amir
2014-03-01
Hallux valgus deformity is a common chronic problem with a reported prevalence of 28.4% and its chief complaint is pain. Thus far, different surgical procedures with their proposed indications have been introduced. This study compared three current procedures, namely the chevron and scarf osteotomies and the McBride procedure. This retrospective cohort was conducted at the Ahvaz University of Medical Sciences on 44 patients with moderate hallux valgus deformity from 2010 and 2013. All of the patients underwent one of the three procedures (chevron, scarf or McBride). Preoperative and follow up radiographies were evaluated in terms of hallux valgus and intermetatarsal angle correction. The Foot and Ankle Disability Index was filled out to assess the functional outcome and the Visual Analogue Scale was used to evaluate pain. Also, satisfaction, aesthetics and the rate of recurrence was evaluated. Hallux valgus angle and intermetatarsal angle correction were significantly higher in scarf, but not in chevron and McBride. However, from amongst the three procedures, there was no significant difference in terms of the Foot and Ankle Disability Index score, aesthetics, satisfaction level, pain score and recurrence rate. Considering that scarf osteotomy had better results in this study, we think that scarf osteotomy can be considered as a first choice for the treatment of moderate hallux valgus deformity.
Flaperon Modification Effect on Jet-Flap Interaction Noise Reduction for Chevron Nozzles
NASA Technical Reports Server (NTRS)
Thomas, Russell H.; Mengle, Vinod G.; Stoker, Robert W.; Brusniak, Leon; Elkoby, Ronen
2007-01-01
Jet-flap interaction (JFI) noise can become an important component of far field noise when a flap is immersed in the engine propulsive stream or is in its entrained region, as in approach conditions for under-the-wing engine configurations. We experimentally study the effect of modifying the flaperon, which is a high speed aileron between the inboard and outboard flaps, at both approach and take-off conditions using scaled models in a free jet. The flaperon modifications were of two types: sawtooth trailing edge and mini vortex generators (vg s). Parametric variations of these two concepts were tested with a round coaxial nozzle and an advanced chevron nozzle, with azimuthally varying fan chevrons, using both far field microphone arrays and phased microphone arrays for source diagnostics purposes. In general, the phased array results corroborated the far field results in the upstream quadrant pointing to JFI near the flaperon trailing edge as the origin of the far field noise changes. Specific sawtooth trailing edges in conjunction with the round nozzle gave marginal reduction in JFI noise at approach, and parallel co-rotating mini-vg s were somewhat more beneficial over a wider range of angles, but both concepts were noisier at take-off conditions. These two concepts had generally an adverse JFI effect when used in conjunction with the advanced chevron nozzle at both approach and take-off conditions.
Modeling and Bayesian Parameter Estimation for Shape Memory Alloy Bending Actuators
2012-02-01
prosthetic hand,” Technology and Health Care 10, 91–106 (2002). 4. Hartl , D., Lagoudas, D., Calkins, F., and Mabe , J., “Use of a ni60ti shape memory...alloy for active jet engine chevron application: I. thermomechanical characterization,” Smart Materials and Structures 19, 1–14 (2010). 5. Hartl , D...Lagoudas, D., Calkins, F., and Mabe , J., “Use of a ni60ti shape memory alloy for active jet engine chevron application: II. experimentally validated
Noise of Embedded High Aspect Ratio Nozzles
NASA Technical Reports Server (NTRS)
Bridges, James E.
2011-01-01
A family of high aspect ratio nozzles were designed to provide a parametric database of canonical embedded propulsion concepts. Nozzle throat geometries with aspect ratios of 2:1, 4:1, and 8:1 were chosen, all with convergent nozzle areas. The transition from the typical round duct to the rectangular nozzle was designed very carefully to produce a flow at the nozzle exit that was uniform and free from swirl. Once the basic rectangular nozzles were designed, external features common to embedded propulsion systems were added: extended lower lip (a.k.a. bevel, aft deck), differing sidewalls, and chevrons. For the latter detailed Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) simulations were made to predict the thrust performance and to optimize parameters such as bevel length, and chevron penetration and azimuthal curvature. Seventeen of these nozzles were fabricated at a scale providing a 2.13 inch diameter equivalent area throat." ! The seventeen nozzles were tested for far-field noise and a few data were presented here on the effect of aspect ratio, bevel length, and chevron count and penetration. The sound field of the 2:1 aspect ratio rectangular jet was very nearly axisymmetric, but the 4:1 and 8:1 were not, the noise on their minor axes being louder than the major axes. Adding bevel length increased the noise of these nozzles, especially on their minor axes, both toward the long and short sides of the beveled nozzle. Chevrons were only added to the 2:1 rectangular jet. Adding 4 chevrons per wide side produced some decrease at aft angles, but increased the high frequency noise at right angles to the jet flow. This trend increased with increasing chevron penetration. Doubling the number of chevrons while maintaining their penetration decreased these effects. Empirical models of the parametric effect of these nozzles were constructed and quantify the trends stated above." Because it is the objective of the Supersonics Project that future design work be done more by physics-based computations and less by experiments, several codes under development were evaluated against these test cases. Preliminary results show that the RANS-based code JeNo predicts the spectral directivity of the low aspect ratio jets well, but has no capability to predict the non-axisymmetry. An effort to address this limitations, used in the RANS-based code of Leib and Goldstein, overpredicted the impact of aspect ratio. The broadband shock noise code RISN, also limited to axisymmetric assumptions, did a good job of predicting the spectral directivity of underexpanded 2:1 cold jet case but was not as successful on high aspect ratio jets, particularly when they are hot. All results are preliminary because the underlying CFD has not been validated yet. An effort using a Large Eddy Simulation code by Stanford University predicted noise that agreed with experiments to within a few dB.
Wagener, Marc L; Driesprong, Marco; Heesterbeek, Petra J C; Verdonschot, Nico; Eygendaal, Denise
2013-08-01
In this study three different methods for fixating the Chevron osteotomy of the olecranon are evaluated. Transcortical fixed Kirschner wires with a tension band, a large cancellous screw with a tension band, and a large cancellous screw alone are compared using Roentgen Stereophotogrammatic Analysis (RSA). The different fixation methods were tested in 17 cadaver specimens by applying increasing repetitive force to the triceps tendon. Forces applied were 200N, 350N, and 500N. Translation and rotation of the osteotomy were recorded using Roentgen Stereophotogrammatic Analysis. Both the fixations with a cancellous screw with tension band and with bi-cortical placed Kirschner wires with a tension band provide enough stability to withstand the forces of normal daily use. Since fixation with a cancellous screw with tension band is a fast and easy method and is related to minimal soft tissue damage this method can preferably be used for fixation of a Chevron osteotomy of the olecranon. © 2013.
NASA Technical Reports Server (NTRS)
Massey, Steven J.; Thomas, Russell H.; AbdolHamid, Khaled S.; Elmiligui, Alaa A.
2003-01-01
A computational and experimental flow field analyses of separate flow chevron nozzles is presented. The goal of this study is to identify important flow physics and modeling issues required to provide highly accurate flow field data which will later serve as input to the Jet3D acoustic prediction code. Four configurations are considered: a baseline round nozzle with and without a pylon, and a chevron core nozzle with and without a pylon. The flow is simulated by solving the asymptotically steady, compressible, Reynolds-averaged Navier-Stokes equations using an implicit, up-wind, flux-difference splitting finite volume scheme and standard two-equation kappa-epsilon turbulence model with a linear stress representation and the addition of a eddy viscosity dependence on total temperature gradient normalized by local turbulence length scale. The current CFD results are seen to be in excellent agreement with Jet Noise Lab data and show great improvement over previous computations which did not compensate for enhanced mixing due to high temperature gradients.
NASA Astrophysics Data System (ADS)
Morovvati, M. R.; Lalehpour, A.; Esmaeilzare, A.
2016-12-01
Reinforcing aluminum with SiC and B4C nano/micro particles can lead to a more efficient material in terms of strength and light weight. The influence of adding these particles to an aluminum 7075 matrix is investigated using chevron-notch fracture toughness test method. The reinforcing factors are type, size (micro/nano), and weight percent of the particles. The fracture parameters are maximum load, notch opening displacement, the work up to fracture and chevron notch plane strain fracture toughness. The findings demonstrate that addition of micro and nano size particles improves the fracture properties; however, increasing the weight percent of the particles leads to increase of fracture properties up to a certain level and after that due to agglomeration of the particles, the improvement does not happen for both particle types and size categories. Agglomeration of particles at higher amounts of reinforcing particles results in improper distribution of particles and reduction in mechanical properties.
NASA Technical Reports Server (NTRS)
Bruckner, Robert
2013-01-01
An improved foil thrust bearing is described that eliminates or reduces the need for forced cooling of the bearing foils while at the same time improves the load capacity of the bearing, enhances damping, provides overload tolerance, and eliminates the high speed load capacity drop-off that plagues the current state of the art. The performance improvement demonstrated by the chevron foil thrust bearing stems from a novel trailing edge shape that splays the hot lubricant in the thin film radially, thus preventing hot lubricant carry-over into the ensuing bearing sector. Additionally, the chevron shaped trailing edge induces vortical mixing of the hot lubricant with the gas that is naturally resident within the inter-pad region of a foil thrust bearing. The elimination of hot gas carry-over in combination with the enhanced mixing has enabled a completely passive thermally managed foil bearing design. Laboratory testing at NASA has confirmed the original analysis and reduced this concept to practice.
Inertial focusing and passive micro-mixing techniques for rare cells capturing microfluidic platform
NASA Astrophysics Data System (ADS)
Phadke, Manisha; Shaner, Sebastian; Shah, Shreyas; Rodriguez, Ygnacio; Wibowo, Denni; Whulanza, Yudan; Teriete, Peter; Allen, Jeff; Kassegne, Sam
2018-02-01
Isolation and capture of rare cells continues to be a daunting task that is still looking for an innovative and efficient method. While a variety of approaches have been suggested over the past several years, immunocapturing in a microfluidic platform carries a substantial promise as shown by recent published works. In this paper, we introduced a combination of inertial focusing and passive micro-mixing through 3D chevron-type features in a microchannel to induce chaotic mixing within antibody-coated microchannels and, ultimately, promote rare cell capture. The device introduced in this work contains curved microchannels that consist of a series of staggered chevron grooves. The curved channels enable inertial focusing while the chevron grooves allow for chaotic mixing. The microfluidics platform microfabricated through soft lithography has a polydimethylsiloxane (PDMS) foundation and was thinly coated with an alginate hydrogel derivatized with streptavidin. We submitted that our qualitative and quantitative results demonstrated the potentials in advancements in rare cell isolation through this integration of two techniques.
Lai, Mun Chun; Rikhraj, Inderjeet Singh; Woo, Yew Lok; Yeo, William; Ng, Yung Chuan Sean; Koo, Kevin
2018-03-01
Minimally invasive surgeries have gained popularity due to less soft tissue trauma and better wound healing. To date, limited studies have compared the outcomes of percutaneous and open osteotomies. This study aims to investigate the clinical and radiological outcomes of percutaneous chevron-Akin osteotomies vs open scarf-Akin osteotomies at 24-month follow-up. We reviewed a prospectively collected database in a tertiary hospital hallux valgus registry. Twenty-nine feet that underwent a percutaneous technique were matched to 58 feet that underwent open scarf and Akin osteotomies. Clinical outcome measures assessed included visual analog scale (VAS) scores, American Orthopaedic Foot & Ankle Society Hallux Metatarsophalangeal-Interphalangeal score (AOFAS Hallux MTP-IP), and Short Form 36 (SF-36) Health Survey. Radiological outcomes included hallux valgus angle (HVA) and intermetatarsal angle (IMA). All patients were prospectively followed up at 6 and 24 months. Both groups showed comparable clinical and radiological outcomes at the 24-month follow-up. However, the percutaneous group demonstrated less pain in the perioperative period ( P < .001). There were significant differences in the change in HVA between the groups but comparable radiological outcomes in IMA at the 24-month follow-up. The percutaneous group demonstrated shorter length of operation ( P < .001). There were no complications in the percutaneous group but 3 wound complications in the open group. We conclude that clinical and radiological outcomes of third-generation percutaneous chevron-Akin osteotomies were comparable with open scarf and Akin osteotomies at 24 months but with significantly less perioperative pain, shorter length of operation, and less risk of wound complications. Level III, retrospective comparative series.
Stabilization of chevron bunionectomy with a capsuloperiosteal flap.
Guclu, Berk; Kaya, Alper; Akan, Burak; Koken, Murat; Kemal Us, Ali
2011-04-01
Distal chevron osteotomy (DCO) for mild to moderate hallux valgus deformity is inherently more stable than the other forms of distal metatarsal osteotomy, but complications such as loss of correction, infection, joint stiffness, delayed union, malunion and nonunion can occur. In this study, we evaluated the use of a capsuloperiosteal flap for stabilization of DCO in the treatment of hallux valgus. A retrospective study was conducted on 59 patients (88 feet) that underwent distal Chevron osteotomy stabilized only with a capsuloperiosteal flap for mild and moderate hallux valgus deformity with a mean followup of 11.3 years. Clinical evaluation was calculated using the hallux score of the American Orthopaedic Foot and Ankle Society (AOFAS). The score improved from a preoperative mean of 52 to a mean of 91.5 points at last followup. Average hallux valgus angle changed from 30.3 degrees preoperatively to 14.2 degrees postoperatively at the last followup. Intermetatarsal angle 1-2 changed from 13.6 degrees preoperatively to 10.2 degrees postoperatively. The correction proved to be consistent with only an average of 3.4-degree correction loss and 4.9-degree loss in the range of motion. Eighty-six feet (97.7%) were pain free. Discomfort with shoewear was absent in 84 feet (95.5%) postoperatively and 24 of 25 (96%) patients were satisfied cosmetically. Capsuloperiosteal flap stabilization of distal chevron osteotomy for mild-moderate hallux valgus yielded excellent clinical results at long-term followup.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muley, A.; Manglik, R.M.
1999-02-01
Experimental heat transfer and isothermal pressure drop data for single-phase water flows in a plate heat exchanger (PHE) with chevron plates are presented. In a single-pass U-type counterflow PHE, three different chevron plate arrangements are considered: two symmetric plate arrangements with {beta} = 30 deg/30 deg and 60 deg/60 deg, and one mixed-plate arrangement with {beta} = 30 deg/60 deg. For water (2 < Pr < 6) flow rates in the 600 < Re < 10{sup 4} regime, data for Nu and f are presented. The results show significant effects of both the chevron angle {beta} and surface area enlargementmore » factor {phi}. As {beta} increases, and compared to a flat-plate pack, up to two to five times higher Nu are obtained; the concomitant f, however, are 13 to 44 times higher. Increasing {phi} also has a similar, though smaller effect. Based on experimental data for Re {ge} 1000 and 30 deg {le} {beta} {le} 60 deg, predictive correlations of the form Nu = C{sub 1}({beta}) D{sub 1}({phi}) Re{sup p1({beta})} Pr{sup 1/3} ({mu}/{mu}{sub w}){sup 0.14} and f = C{sub 2}({beta}) D{sub 2}({phi}) Re{sup p2({beta})} are devised. Finally, at constant pumping power, and depending upon Re, {beta}, and {phi}, the heat transfer is found to be enhanced by up to 2.8 times that in an equivalent flat-plate channel.« less
Effects of the lapidus arthrodesis and chevron bunionectomy on plantar forefoot pressures.
King, Christy M; Hamilton, Graham A; Ford, Lawrence A
2014-01-01
Hallux valgus with or without first ray insufficiency has been strongly implicated as a contributing factor in lesser metatarsal overload. The principle goals of a bunionectomy are to relieve the pain, correct the deformity, and restore first metatarsophalangeal joint congruity. Until now, little evidence has been available to assess the effects of bunionectomy procedures on forefoot pressure. The primary aim of the present prospective study was to evaluate the preoperative and postoperative plantar pressures after 2 specific bunionectomies: the chevron bunionectomy and Lapidus arthrodesis. A total of 68 subjects, 34 in each group, were included for radiographic and pedographic evaluation. Both procedures demonstrated radiographic improvements in the mean intermetatarsal and hallux abductus angles. The mean hallux plantar pressure decreased significantly in both procedure groups (p < .001). However, Lapidus group exhibited an increase in the mean fifth metatarsal head plantar pressure (p = .008) and pressure under the fifth metatarsal as a percentage of the total forefoot pressure (p = .01). Furthermore, the pressure under the second metatarsal as a percentage of the total forefoot pressure decreased significantly (p = .01). This study suggests that the Lapidus arthrodesis and chevron bunionectomy both provide correction for hallux valgus deformity, but when comparing forefoot load sharing pressures, the Lapidus arthrodesis appeared to have greater influence on the load sharing distribution of forefoot pressure than did the bunionectomy employing the chevron osteotomy. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Olms, Kai; Randt, Thorsten; Reimers, Nils; Zander, Nils; Schulz, Arndt P
2014-01-01
Reconstructive osteotomies for the treatment of Hallux valgus are among the most prevalent procedures in foot and ankle surgery. The combination of biodegradable materials with an innovative method for fixation by application of ultrasonic energy facilitates a new bonding method for fractures or osteotomies. As clinical experience is still limited, the aim of this study was to assess the safety and performance of the SonicPin system for fixation of Austin/Chevron osteotomies. Chevron osteotomy was performed on 30 patients for the treatment of Hallux valgus. The used SonicPins were made from polylactide and are selectively melted into the cancellous bone structure during insertion by ultrasonic energy. Patients were followed for one year, which included X-ray and MRI examinations as well as evaluation of life quality by EQ-5D (EuroQol). The MRI after three months showed adequate bone healing in all cases and no signs of foreign body reactions, which was again confirmed by MRI 12 months postoperatively. The bony healing after 12 months was uneventful without any signs of foreign body reactions. In summary, based on the low complication rate and the significant improvement in health related quality of life (EQ-5D) reported in this study, fixation of an Austin/Chevron osteotomy with a SonicPin for treatment of Hallux valgus can be considered to be safe and efficient over the short term. Therapeutic Level III.
Pentikainen, Ilkka; Ojala, Risto; Ohtonen, Pasi; Piippo, Jouni; Leppilahti, Juhana
2014-12-01
The purpose of this article was to analyze the long-term radiologic results after distal chevron osteotomy for hallux valgus treatment and to determine the preoperative radiographic factors correlating with radiological recurrence of the deformity. The study included 100 consecutive patients who received distal chevron osteotomy for hallux valgus. The osteotomy included fixation with an absorbable pin in 50 cases, and no fixation in the other 50. For 6 weeks postoperatively, half of each group used a soft cast and half had a traditional elastic bandage. Weight-bearing radiographs were evaluated at 6 weeks, 6 months, 1 year, and a mean of 7.9 (range, 5.8-9.4) years postoperatively. At the final follow-up, radiological recurrence of hallux valgus deformity (HVA > 15 degrees) was observed in 56 feet (73%). Eleven feet (14%) had mild recurrence (HVA < 20 degrees), 44 (57%) moderate (20 degrees ≥ HVA < 40 degrees), and 1 (1%) severe (HVA ≥ 40 degrees). All recurrences were painless, and thus no revision surgery was required. Long-term hallux valgus recurrence was significantly affected by preoperative congruence, DMAA, sesamoid position, HVA, and I/II IMA. Radiological recurrence of hallux valgus deformity of 15 degrees or more was very common at long-term follow-up after distal chevron osteotomy. Preoperative congruence, DMAA, sesamoid position (LaPorta), HVA, and I/II IMA significantly affected recurrence. Level III, comparative case series. © The Author(s) 2014.
Olms, Kai; Randt, Thorsten; Reimers, Nils; Zander, Nils; Schulz, Arndt P.
2014-01-01
Reconstructive osteotomies for the treatment of Hallux valgus are among the most prevalent procedures in foot and ankle surgery. The combination of biodegradable materials with an innovative method for fixation by application of ultrasonic energy facilitates a new bonding method for fractures or osteotomies. As clinical experience is still limited, the aim of this study was to assess the safety and performance of the SonicPin system for fixation of Austin/Chevron osteotomies. Chevron osteotomy was performed on 30 patients for the treatment of Hallux valgus. The used SonicPins were made from polylactide and are selectively melted into the cancellous bone structure during insertion by ultrasonic energy. Patients were followed for one year, which included X-ray and MRI examinations as well as evaluation of life quality by EQ-5D (EuroQol). The MRI after three months showed adequate bone healing in all cases and no signs of foreign body reactions, which was again confirmed by MRI 12 months postoperatively. The bony healing after 12 months was uneventful without any signs of foreign body reactions. In summary, based on the low complication rate and the significant improvement in health related quality of life (EQ-5D) reported in this study, fixation of an Austin/Chevron osteotomy with a SonicPin for treatment of Hallux valgus can be considered to be safe and efficient over the short term. Level of Clinical Evidence: Therapeutic Level III. PMID:24851140
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tormey, D.; Waldron, J.; Culbertson, D.
When regulatory concern is high, it is critical to address potential ecological impacts early, and hence [open quotes]close the door[close quotes] on further unnecessary studies, as illustrated by the Chevron Estero Marine Terminal case study. Cutter stock (diesel-like hydrocarbons) leaked from a facility sump, reached the water table, and migrated laterally an unknown distance. Media reports led to heightened public and regulatory concern, and the information gap led to worst-case assumptions about the extent and impact of the release to the biota of a nearby creek (Toro Creek). Chevron undertook a rapid assessment with two goals: define the extent ofmore » cutter stock in soil and groundwater, and close the door on expensive biological studies of Toro Creek. The assessment consisted of installing a large number of small-diameter soil borings and temporary well points, monitor wells, and analyzing soil, groundwater, and hydraulic gradient. The information gap was very rapidly filled with the following comprehensive picture: (1) the cutter stock had mixed with heavy crude oil, was highly adsorptive to soil and practically insoluble in water; (2) the cutter stock had not reached Toro Creek; (3) Toro Creek is always a losing stream, hydraulically connected to groundwater beneath the Chevron facility; (4) the groundwater basin is isolated by bedrock boundaries. Early attention to Toro Creek and the Pacific Ocean, and open communication with concerned agencies effectively limited the investigation to soil and water.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tormey, D.; Waldron, J.; Culbertson, D.
When regulatory concern is high, it is critical to address potential ecological impacts early, and hence {open_quotes}close the door{close_quotes} on further unnecessary studies, as illustrated by the Chevron Estero Marine Terminal case study. Cutter stock (diesel-like hydrocarbons) leaked from a facility sump, reached the water table, and migrated laterally an unknown distance. Media reports led to heightened public and regulatory concern, and the information gap led to worst-case assumptions about the extent and impact of the release to the biota of a nearby creek (Toro Creek). Chevron undertook a rapid assessment with two goals: define the extent of cutter stockmore » in soil and groundwater, and close the door on expensive biological studies of Toro Creek. The assessment consisted of installing a large number of small-diameter soil borings and temporary well points, monitor wells, and analyzing soil, groundwater, and hydraulic gradient. The information gap was very rapidly filled with the following comprehensive picture: (1) the cutter stock had mixed with heavy crude oil, was highly adsorptive to soil and practically insoluble in water; (2) the cutter stock had not reached Toro Creek; (3) Toro Creek is always a losing stream, hydraulically connected to groundwater beneath the Chevron facility; (4) the groundwater basin is isolated by bedrock boundaries. Early attention to Toro Creek and the Pacific Ocean, and open communication with concerned agencies effectively limited the investigation to soil and water.« less
Comparison of microtweezers based on three lateral thermal actuator configurations
NASA Astrophysics Data System (ADS)
Luo, J. K.; Flewitt, A. J.; Spearing, S. M.; Fleck, N. A.; Milne, W. I.
2005-06-01
Thermal actuator-based microtweezers with three different driving configurations have been designed, fabricated and characterized. Finite element analysis has been used to model the device performance. It was found that one configuration of microtweezer, based on two lateral bimorph thermal actuators, has a small displacement (tip opening of the tweezers) and a very limited operating power range. An alternative configuration consisting of two horizontal hot bars with separated beams as the arms can deliver a larger displacement with a much-extended operating power range. This structure can withstand a higher temperature due to the wider beams used, and has flexible arms for increased displacement. Microtweezers driven by a number of chevron structures in parallel have similar maximum displacements but at a cost of higher power consumption. The measured temperature of the devices confirms that the device with the chevron structure can deliver the largest displacement for a given working temperature, while the bimorph thermal actuator design has the highest operating temperature at the same power due to its thin hot arm, and is prone to structural failure.
Effects of annealing on arrays of Ge nanocolumns formed by glancing angle deposition
NASA Astrophysics Data System (ADS)
Khare, C.; Gerlach, J. W.; Höche, T.; Fuhrmann, B.; Leipner, H. S.; Rauschenbach, B.
2012-10-01
Post-deposition thermal annealing of glancing angle deposited Ge nanocolumn arrays was carried out in a continuous Ar-flow at temperatures ranging from TA = 300 to 800 °C for different annealing durations. Morphological alterations and the recrystallization process induced by the thermal annealing treatment were investigated for the Ge nanocolumns deposited on planar and pre-patterned Si substrates. From X-ray diffraction (XRD) measurements, the films annealed at TA ≥ 500 °C were found to be polycrystalline. On planar Si substrates, at TA = 600 °C nanocolumns exhibited strong coarsening and merging, while a complete disintegration of the nanocolumns was detected at TA = 700 °C. The morphology of nanostructures deposited on pre-patterned substrates differs substantially, where the merging or column-disintegration effect was absent at elevated annealing temperatures. The two-arm-chevron nanostructures grown on pre-patterned substrates retained their complex shape and morphology, after extended annealing intervals. Investigations by transmission electron microscopy revealed nanocrystalline domains of the order of 5-30 nm (in diameter) present within the chevron structures after the annealing treatment.
2011-11-01
sensor. volume 79781K. Proceedings of the SPIE 7978, 2011. [9] D.J. Hartl , D.C. Lagoudas, F.T. Calkins, and J.H. Mabe . Use of a ni60ti shape memory...alloy for active jet engine chevron application: I. thermomechanical characterization. Smart Materials and Structures, 19:1–14, 2010. [10] D.J. Hartl ...D.C. Lagoudas, F.T. Calkins, and J.H. Mabe . Use of a ni60ti shape memory alloy for active jet engine chevron application: II. experimentally validated
Investigation of Acoustic Emission during Fracture Toughness Testing of Chevron-Notched Specimens.
1984-03-01
chevron-notched specimlens was employed to investigate crack growth in four steels )rel)ared by electroslag-remelt casting. 15-5PH, AISI 4140 , D6AC, and...this investigation: 15-SPH, AISI 4140 , D6AC and AISI 440C. The composition of each steel is given in Table 1. Castings were prepared by electro- slag...well defined, it appears that the AISI 4140 (Figure 2b) and the D6AC (Figure 2c) failed primarily by cleavage also. The fracture illustrated in Figure
1989-01-01
measured in these investigations <in the field> is apparently the factor the engineer must deal with in problems of design " E7]. With the proliferation of...normal quality control methods are used; there is not much that can be done during construction to improve AC surface friction E81. In design , soft...chevron-type cuts and chipping in tires [23]. Adjustments in aircraft tire design were made to eliminate this type of tire distress. In fact, now it
Source Identification and Location Techniques
NASA Technical Reports Server (NTRS)
Weir, Donald; Bridges, James; Agboola, Femi; Dougherty, Robert
2001-01-01
Mr. Weir presented source location results obtained from an engine test as part of the Engine Validation of Noise Reduction Concepts program. Two types of microphone arrays were used in this program to determine the jet noise source distribution for the exhaust from a 4.3 bypass ratio turbofan engine. One was a linear array of 16 microphones located on a 25 ft. sideline and the other was a 103 microphone 3-D "cage" array in the near field of the jet. Data were obtained from a baseline nozzle and from numerous nozzle configuration using chevrons and/or tabs to reduce the jet noise. Mr. Weir presented data from two configurations: the baseline nozzle and a nozzle configuration with chevrons on both the core and bypass nozzles. This chevron configuration had achieved a jet noise reduction of 4 EPNdB in small scale tests conducted at the Glenn Research Center. IR imaging showed that the chevrons produced significant improvements in mixing and greatly reduced the length of the jet potential core. Comparison of source location data from the 1-D phased array showed a shift of the noise sources towards the nozzle and clear reductions of the sources due to the noise reduction devices. Data from the 3-D array showed a single source at a frequency of 125 Hz. located several diameters downstream from the nozzle exit. At 250 and 400 Hz., multiple sources, periodically spaced, appeared to exist downstream of the nozzle. The trend of source location moving toward the nozzle exit with increasing frequency was also observed. The 3-D array data also showed a reduction in source strength with the addition of chevrons. The overall trend of source location with frequency was compared for the two arrays and with classical experience. Similar trends were observed. Although overall trends with frequency and addition of suppression devices were consistent between the data from the 1-D and the 3-D arrays, a comparison of the details of the inferred source locations did show differences. A flight test is planned to determine if the hardware tested statically will achieve similar reductions in flight.
Refinery spreadsheet highlights microcomputer process applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tucker, M.A.
1984-01-23
Microcomputer applications in the process areas at Chevron U.S.A. refineries and at the Chevron Research Co. illustrate how the microcomputer has changed the way we do our jobs. This article will describe major uses of the microcomputer as a personal work tool in Chevron process areas. It will also describe how and why many of Chevron's microcomputer applications were developed and their characteristics. One of our earliest microcomputer applications, developed in late 1981, was an electronic spreadsheet program using a small desktop microcomputer. It was designed to help a refinery planner prepare monthly plans for a small portion of onemore » of our major refineries. This particular microcomputer had a tiny 4-in. screen, and the reports were several strips of print-out from the microcomputer's 3-in.-wide internal printer taped together. In spite of these archaic computing conditions, it was a successful application. It automated what had been very tedious and time-consuming calculations with a pencil, a calculator, and a great deal of erasing. It eliminated filling out large ''horseblanket'' reports. The electronic spreadsheet was also flexible; the planner could easily change the worksheet to match new operating constraints, new process conditions, and new feeds and products. Fortunately, within just a few months, this application graduated to a similar electronic spreadsheet program on a new, more powerful microcomputer. It had a bigger display screen and a letter-size printer. The same application is still in use today, although it has been greatly enhanced and altered to match extensive plant modifications. And there are plans to expand it again onto yet another, more powerful microcomputer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guerra, T.; Azevedo, S.; Kaschny, J.R.
2017-04-15
Graphene nanoribbons are predicted to be essential components in future nanoelectronics. The size, edge type, arrangement of atoms and width of nanoribbons drastically change their properties. Boronnitrogencarbon nanoribbons properties are not fully understood so far. In the present contribution it was investigated the structural, electronic and magnetic properties of chevron-type carbon, boron nitride and BC{sub 2}N nanoribbons, using first-principles calculations. The results indicate that the structural stability is closely related to the discrepancies in the bond lengths, which can induce structural deformations and stress. Such nanoribbons present a wide range of electronic behaviors, depending on their composition and particularities ofmore » the atomic arrangement. A net magnetic moment is found for structures that present carbon atoms at the nanoribbon borders. Nevertheless, the calculated magnetic moment depends on the peculiarities of the symmetric arrangement of atoms and imbalance of carbon atoms between different sublattices. It was found that all structures which have a significant energy gap do not present magnetic moment, and vice-versa. Such result indicates the strong correlation between the electronic and magnetic properties of the chevron-type nanoribbons. - Highlights: • Small discrepancies between distinct bond lengths can influence the formation energy of the BC{sub 2}N nanoribbons. • The electronic behavior of the BC{sub 2}N chevron-type nanoribbons depends on the atomic arrangement and structural symmetries. • There is a strong correlation between the electronic and magnetic properties for the BC{sub 2}N structures.« less
Discovery Of A Rossby Wave In Jupiter's South Equatorial Region
NASA Technical Reports Server (NTRS)
Simon-Miller, Amy A.; Choi, D. S.; Rogers, J. H.; Gierasch, P. J.
2012-01-01
A detailed study of the chevron-shaped dark spots on the strong southern equatorial wind jet near 7.5 deg S planetographic latitude shows variations in velocity with longitude and time. The chevrons move with velocities near the maximum wind jet velocity of approx.140 m/s, as deduced by the history of velocities at this latitude and the magnitude of the symmetric wind jet near 7 deg N latitude. Their repetitive nature is consistent with an inertia-gravity wave (n = 75-100) with phase speed up to 25 m/s, relative to the local flow, but the identity of this wave mode is not well constrained. However, high spatial resolution movies from Cassini images show that the chevrons oscillate in latitude with a approx.7-day period. This oscillating motion has a wavelength of approx.20 deg and a speed of approx.100 m/s, following a pattern similar to that seen in the Rossby wave plumes of the North Equatorial Zone, and possibly reinforced by it, though they are not perfectly in phase. The transient anticyclonic South Equatorial Disturbance (SED) may be a similar wave feature, but moves at slower velocity. All data show chevron latitude variability, but it is unclear if this Rossby wave is present during other epochs, without time series movies that fully delineate it. In the presence of multiple wave modes, the difference in dominant cloud appearance between 7 deg N and 7.5 deg S may be due to the presence of the Great Red Spot, either through changes in stratification and stability or by acting as a wave boundary.
Three-dimensional finite-element analysis of chevron-notched fracture specimens
NASA Technical Reports Server (NTRS)
Raju, I. S.; Newman, J. C., Jr.
1984-01-01
Stress-intensity factors and load-line displacements were calculated for chevron-notched bar and rod fracture specimens using a three-dimensional finite-element analysis. Both specimens were subjected to simulated wedge loading (either uniform applied displacement or uniform applied load). The chevron-notch sides and crack front were assumed to be straight. Crack-length-to-specimen width ratios (a/w) ranged from 0.4 to 0.7. The width-to-thickness ratio (w/B) was 1.45 or 2. The bar specimens had a height-to-width ratio of 0.435 or 0.5. Finite-element models were composed of singularity elements around the crack front and 8-noded isoparametric elements elsewhere. The models had about 11,000 degrees of freedom. Stress-intensity factors were calculated by using a nodal-force method for distribution along the crack front and by using a compliance method for average values. The stress intensity factors and load-line displacements are presented and compared with experimental solutions from the literature. The stress intensity factors and load-line displacements were about 2.5 and 5 percent lower than the reported experimental values, respectively.
Structural, electronic and magnetic properties of chevron-type graphene, BN and BC2N nanoribbons
NASA Astrophysics Data System (ADS)
Guerra, T.; Azevedo, S.; Kaschny, J. R.
2017-04-01
Graphene nanoribbons are predicted to be essential components in future nanoelectronics. The size, edge type, arrangement of atoms and width of nanoribbons drastically change their properties. Boronnitrogencarbon nanoribbons properties are not fully understood so far. In the present contribution it was investigated the structural, electronic and magnetic properties of chevron-type carbon, boron nitride and BC2N nanoribbons, using first-principles calculations. The results indicate that the structural stability is closely related to the discrepancies in the bond lengths, which can induce structural deformations and stress. Such nanoribbons present a wide range of electronic behaviors, depending on their composition and particularities of the atomic arrangement. A net magnetic moment is found for structures that present carbon atoms at the nanoribbon borders. Nevertheless, the calculated magnetic moment depends on the peculiarities of the symmetric arrangement of atoms and imbalance of carbon atoms between different sublattices. It was found that all structures which have a significant energy gap do not present magnetic moment, and vice-versa. Such result indicates the strong correlation between the electronic and magnetic properties of the chevron-type nanoribbons.
An Analysis of Model Scale Data Transformation to Full Scale Flight Using Chevron Nozzles
NASA Technical Reports Server (NTRS)
Brown, Clifford; Bridges, James
2003-01-01
Ground-based model scale aeroacoustic data is frequently used to predict the results of flight tests while saving time and money. The value of a model scale test is therefore dependent on how well the data can be transformed to the full scale conditions. In the spring of 2000, a model scale test was conducted to prove the value of chevron nozzles as a noise reduction device for turbojet applications. The chevron nozzle reduced noise by 2 EPNdB at an engine pressure ratio of 2.3 compared to that of the standard conic nozzle. This result led to a full scale flyover test in the spring of 2001 to verify these results. The flyover test confirmed the 2 EPNdB reduction predicted by the model scale test one year earlier. However, further analysis of the data revealed that the spectra and directivity, both on an OASPL and PNL basis, do not agree in either shape or absolute level. This paper explores these differences in an effort to improve the data transformation from model scale to full scale.
Optimizing Micromixer Surfaces To Deter Biofouling.
Waters, James T; Liu, Ya; Li, Like; Balazs, Anna C
2018-03-07
Using computational modeling, we show that the dynamic interplay between a flowing fluid and the appropriately designed surface relief pattern can inhibit the fouling of the substrate. We specifically focus on surfaces that are decorated with three-dimensional (3D) chevron or sawtooth "micromixer" patterns and model the fouling agents (e.g., cells) as spherical microcapsules. The interaction between the imposed shear flow and the chevrons on the surface generates 3D vortices in the system. We pinpoint a range of shear rates where the forces from these vortices can rupture the bonds between the two mobile microcapsules near the surface. Notably, the patterned surface offers fewer points of attachment than a flat substrate, and the shear flows readily transport the separated capsules away from the layer. We contrast the performance of surfaces that encompass rectangular posts, chevrons, and asymmetric sawtooth patterns and thereby identify the geometric factors that cause the sawtooth structure to be most effective at disrupting the bonding between the capsules. By breaking up nascent clusters of contaminant cells, these 3D relief patterns can play a vital role in disrupting the biofouling of surfaces immersed in flowing fluids.
This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Petition Database available at www2.epa.gov/title-v-operating-permits/title-v-petition-database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
NASA Astrophysics Data System (ADS)
Woody, Craig; Azmoun, Babak; Majka, Richard; Phipps, Michael; Purschke, Martin; Smirnov, Nikolai
2018-02-01
A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10×10×10 cm3 drift volume where the charge is drifted to a 10×10 cm2 triple GEM detector. The charge is measured on a readout plane consisting of 2×10 mm2 chevron pads which provide a spatial resolution ˜ 100 μm per point in the chevron direction along with dE/dx information. The Cherenkov portion of the detector consists of a second 10×10 cm2 triple GEM with a photosensitive CsI photocathode on the top layer. This detector measures Cherenkov light produced in the drift gas of the TPC by high velocity particles which are above threshold. CF4 or CF4 mixtures will be used as the drift gas which are highly transparent to UV light and can provide excellent efficiency for detecting Cherenkov photons. The drift gas is also used as the operating gas for both GEM detectors. The prototype detector has been constructed and is currently being tested in the lab with sources and cosmic rays, and additional tests are planned in the future to study the detector in a test beam.
Ayvaz, Mehmet; Olgun, Z Deniz; Demirkiran, H Gokhan; Alanay, Ahmet; Yazici, Muharrem
2014-01-01
Congenital kyphoscoliosis is a disorder that often requires surgical treatment. Although many methods of surgical treatment exist, posterior-only vertebral column resection with instrumentation and fusion seem to have become the gold standard for very severe and very rigid curves. Multiple chevron and concave rib osteotomies have been previously reported to be effective in the treatment of neglected severe idiopathic curves. We hypothesized that this method may also be used successfully in the treatment of congenital kyphoscoliosis. To evaluate the effectiveness and safety of multiple chevron osteotomies combined with concave rib osteotomy and posterior pedicle screw instrumentation. Retrospective chart review in the spine service of a large university hospital. Adolescent patients undergoing a specific surgical treatment for the indication of rigid congenital kyphoscoliotic deformity. Radiographic images were used for the measurement of deformity correction. The Turkish version of the Scoliosis Research Society 22 (SRS-22) Patient Questionnaire has been used as a clinical outcome measure in the patient population. A retrospective chart review was performed. Patients admitted to Hacettepe Hospital Spine Center during the period of 2005 to 2009 were included. Criteria for inclusion were as follows: adolescent age group (10-16 years); congenital kyphoscoliosis; formation and/or segmentation defect of at least two vertebral motion segments; surgical treatment of deformity by posterior all-pedicle screw instrumentation, multiple chevron osteotomies, and multiple concave rib osteotomies; follow-up of at least 24 months; and a complete set of preoperative, postoperative, and follow-up standing posteroanterior and lateral full spinal radiographs. The patients' hospital records and X-rays were reviewed. Duration of surgery, intraoperative blood loss, postoperative transfusion requirements, postoperative stay in postanesthesia care unit (PACU), time of hospitalization, and complications were recorded. Deformity in both coronal and sagittal planes was analyzed for correction and maintenance of the correction in preoperative, postoperative, and follow-up radiographs. Patients' health-related quality of life was assessed using the SRS-22 questionnaire at the final follow-up. Eighteen patients met the inclusion criteria. Their average age was 13.6 years (range, 11-16 years). Chevron osteotomies were performed at apical segments (three to seven levels) and concave rib osteotomies at Cobb-to-Cobb (five to eight levels). No patient had preoperative cord compression because of the sharply angulated deformity or neurologic deficit. The average preoperative scoliosis was 66.0° (range, 31°-116°), 52.4° (range, 22°-85°) on flexibility X-rays, and became 24.9° (range, 12°-52°) postoperatively. The average preoperative global kyphosis (T2-T12) of 75.9° (range, 50°-106°) became 49.5° (range, 18°-66°). The average preoperative local kyphosis of 71.9° (range, 35°-114°) became 31.4° (range, -44° to 64°). The average intraoperative bleeding was 989 cc, surgical time was 292 minutes, and intraoperative transfusion was 2.3 units. The maximum PACU stay was overnight. There were no neurologic complications except one pneumothorax and one pneumonia. The average follow-up was 34.3 months. At follow-up, average scoliosis was 27.5° (range, 10°-50°), global kyphosis was 50.3° (range, 28°-73°), and local kyphosis was 36.9°(range, -36° to 58°). Performed on the last follow-up, the average scores for the five domains of SRS-22 were 4.3, 4.4, 4.2, 4.1, and 4.8 for function, pain, self-image, mental health, satisfaction, and total, respectively. Multiple chevron and concave rib osteotomies with posterior instrumentation provide an acceptable rate of deformity correction and maintenance of correction at 2 years with acceptable intraoperative bleeding, surgical time, postoperative morbidity, and rate of complications. It can be considered as an alternative in the treatment of rigid congenital curves involving more than three levels or multiple curves separated by at least two segments that would otherwise require multiple vertebral resections. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Ghosh, Asish; Jenkins, Michael G.; Ferber, Mattison K.; Peussa, Jouko; Salem, Jonathan A.
1992-01-01
The quasi-static fracture behaviors of monolithic ceramics (SiC, Si3N4, MgAl2O4), self-reinforced monoliths (acicular grained Si3N4, acicular grained mullite), and ceramic matrix composites (SiC whisker/Al2O3 matrix, TiB2 particulate/SiC matrix, SiC fiber/CVI SiC matrix, Al2O3 fiber/CVI SiC matrix) were measured over the temperature range of 20 to 1400 C. The chevron notched, bend bar test geometry was essential for characterizing the elevated temperature fracture resistances of this wide range of quasi-brittle materials during stable crack growth. Fractography revealed the differences in the fracture behavior of the different materials at the various temperatures. The fracture resistances of the self-reinforced monoliths were comparable to those of the composites and the fracture mechanisms were found to be similar at room temperature. However at elevated temperatures the differences of the fracture behavior became apparent where the superior fracture resistance of the self-reinforced monoliths were attributed to the minor amounts of glassy, intergranular phases which were often more abundant in the composites and affected the fracture behavior when softened by elevated temperatures.
Permian paleoclimate data from fluid inclusions in halite
Benison, K.C.; Goldstein, R.H.
1999-01-01
This study has yielded surface water paleotemperatures from primary fluid inclusions in mid Permian Nippewalla Group halite from western Kansas. A 'cooling nucleation' method is used to generate vapor bubbles in originally all-liquid primary inclusions. Then, surface water paleotemperatures are obtained by measuring temperatures of homogenization to liquid. Homogenization temperatures ranged from 21??C to 50??C and are consistent along individual fluid inclusion assemblages, indicating that the fluid inclusions have not been altered by thermal reequilibration. Homogenization temperatures show a range of up to 26??C from base to top of individual cloudy chevron growth bands. Petrographic and fluid inclusion evidence indicate that no significant pressure correction is needed for the homogenization temperature data. We interpret these homogenization temperatures to represent shallow surface water paleotemperatures. The range in temperatures from base to top of single chevron bands may reflect daily temperatures variations. These Permian surface water temperatures fall within the same range as some modern evaporative surface waters, suggesting that this Permian environment may have been relatively similar to its modern counterparts. Shallow surface water temperatures in evaporative settings correspond closely to local air temperatures. Therefore, the Permian surface water temperatures determined in this study may be considered proxies for local Permian air temperatures.
Enhanced heat transfer characteristics of viscous liquid flows in a chevron plate heat exchanger
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muley, A.; Manglik, R.M.; Metwally, H.M.
1999-11-01
Thermal processing and manufacturing in the chemical, foods, pharmaceutical, hygiene products, and biochemical industries invariably involve heating and cooling of highly viscous fluid media. These fluids tend to flow in the low Reynolds number regime, inherently have relatively low heat transfer coefficients, and are often temperature sensitive and prone to thermal degradation in the presence of large temperature differences. In recent times, plate heat exchangers (PHEs) have found increasing usage in such applications, primarily due to their features that promote enhanced heat transfer, and provide for the flexibility in altering their unit thermal size with ease, close approach temperature operation,more » and mitigation of thermal degradation of the process fluid. Here, steady-state heat transfer and pressure drop data for single-phase viscous fluid flows (2 {le} Re {le} 400) in a single-pass U-type counterflow plate heat exchanger (PHE) with chevron plates are presented. With vegetable oil as test fluid (130 {lt} Pr {lt} 290), three different plate arrangements are employed: two symmetric ({beta} = 30 deg/30 deg and 60 deg/60 deg) and one mixed ({beta} = 30 deg/60 deg). The effects of chevron angle {beta}, corrugation aspect ratio {gamma}, and flow conditions (Re, Pr, {mu}/{mu}{sub w}) on Nu and f characteristics of the PHE are delineated. The results show a rather complex influence of plate surface corrugations on the enhanced thermal-hydraulic behavior. Relative to the performance of equivalent flat-plate packs, chevron plates sustain up to 2.9 times higher heat transfer rates on a fixed geometry and constant pumping power basis, and require up to 48% less surface area for the fixed heat load and pressure drop constraint.« less
Propulsion Airframe Aeroacoustic Integration Effects for a Hybrid Wing Body Aircraft Configuration
NASA Technical Reports Server (NTRS)
Czech, Michael J.; Thomas, Russell H.; Elkoby, Ronen
2010-01-01
An extensive experimental investigation was performed to study the propulsion airframe aeroacoustic effects of a high bypass ratio engine for a hybrid wing body aircraft configuration where the engine is installed above the wing. The objective was to provide an understanding of the jet noise shielding effectiveness as a function of engine gas condition and location as well as nozzle configuration. A 4.7% scale nozzle of a bypass ratio seven engine was run at characteristic cycle points under static and forward flight conditions. The effect of the pylon and its orientation on jet noise was also studied as a function of bypass ratio and cycle condition. The addition of a pylon yielded significant spectral changes lowering jet noise by up to 4dB at high polar angles and increasing it by 2 to 3dB at forward angles. In order to assess jet noise shielding, a planform representation of the airframe model, also at 4.7% scale was traversed relative to the jet nozzle from downstream to several diameters upstream of the wing trailing edge. Installations at two fan diameters upstream of the wing trailing edge provided only limited shielding in the forward arc at high frequencies for both the axisymmetric and a conventional round nozzle with pylon. This was consistent with phased array measurements suggesting that the high frequency sources are predominantly located near the nozzle exit and, consequently, are amenable to shielding. The mid to low frequencies sources were observed further downstream and shielding was insignificant. Chevrons were designed and used to impact the distribution of sources with the more aggressive design showing a significant upstream migration of the sources in the mid frequency range. Furthermore, the chevrons reduced the low frequency source levels and the typical high frequency increase due to the application of chevron nozzles was successfully shielded. The pylon was further modified with a technology that injects air through the shelf of the pylon which was effective in reducing low frequency noise and moving jet noise sources closer to the nozzle exit. In general, shielding effectiveness varied as a function of cycle condition with the cutback condition producing higher shielding compared to sideline power. The configuration with a more strongly immersed chevron and a pylon oriented opposite to the microphones produced the largest reduction in jet noise. In addition to the jet noise source, the shielding of a broadband point noise source was documented with up to 20 dB of noise reduction at directivity angles directly under the shielding surface.
Propulsion Airframe Aeroacoustic Integration Effects for a Hybrid Wing Body Aircraft Configuration
NASA Technical Reports Server (NTRS)
Czech, Michael J.; Thomas, Russell H; Elkoby, Ronen
2012-01-01
An extensive experimental investigation was performed to study the propulsion airframe aeroacoustic effects of a high bypass ratio engine for a hybrid wing body aircraft configuration where the engine is installed above the wing. The objective was to provide an understanding of the jet noise shielding effectiveness as a function of engine gas condition and location as well as nozzle configuration. A 4.7% scale nozzle of a bypass ratio seven engine was run at characteristic cycle points under static and forward flight conditions. The effect of the pylon and its orientation on jet noise was also studied as a function of bypass ratio and cycle condition. The addition of a pylon yielded significant spectral changes lowering jet noise by up to 4 dB at high polar angles and increasing it by 2 to 3 dB at forward angles. In order to assess jet noise shielding, a planform representation of the airframe model, also at 4.7% scale was traversed such that the jet nozzle was positioned from downstream of to several diameters upstream of the airframe model trailing edge. Installations at two fan diameters upstream of the wing trailing edge provided only limited shielding in the forward arc at high frequencies for both the axisymmetric and a conventional round nozzle with pylon. This was consistent with phased array measurements suggesting that the high frequency sources are predominantly located near the nozzle exit and, consequently, are amenable to shielding. The mid to low frequency sources were observed further downstream and shielding was insignificant. Chevrons were designed and used to impact the distribution of sources with the more aggressive design showing a significant upstream migration of the sources in the mid frequency range. Furthermore, the chevrons reduced the low frequency source levels and the typical high frequency increase due to the application of chevron nozzles was successfully shielded. The pylon was further modified with a technology that injects air through the shelf of the pylon which was effective in reducing low frequency noise and moving jet noise sources closer to the nozzle exit. In general, shielding effectiveness varied as a function of cycle condition with the cutback condition producing higher shielding compared to sideline power. The configuration with a more strongly immersed chevron and a pylon oriented opposite to the microphones produced the largest reduction in jet noise. In addition to the jet noise source, the shielding of a broadband point noise source was documented with up to 20 dB of noise reduction at directivity angles directly under the shielding surface.
Probing optical excitations in chevron-like armchair graphene nanoribbons.
Denk, Richard; Lodi-Rizzini, Alberto; Wang, Shudong; Hohage, Michael; Zeppenfeld, Peter; Cai, Jinming; Fasel, Roman; Ruffieux, Pascal; Berger, Reinhard Franz Josef; Chen, Zongping; Narita, Akimitsu; Feng, Xinliang; Müllen, Klaus; Biagi, Roberto; De Renzi, Valentina; Prezzi, Deborah; Ruini, Alice; Ferretti, Andrea
2017-11-30
The bottom-up fabrication of graphene nanoribbons (GNRs) has opened new opportunities to specifically tune their electronic and optical properties by precisely controlling their atomic structure. Here, we address excitation in GNRs with periodic structural wiggles, the so-called chevron GNRs. Based on reflectance difference and high-resolution electron energy loss spectroscopies together with ab initio simulations, we demonstrate that their excited-state properties are of excitonic nature. The spectral fingerprints corresponding to different reaction stages in their bottom-up fabrication are also unequivocally identified, allowing us to follow the exciton build-up from the starting monomer precursor to the final GNR structure.
Three-dimensional analysis of chevron-notched specimens by boundary integral method
NASA Technical Reports Server (NTRS)
Mendelson, A.; Ghosn, L.
1983-01-01
The chevron-notched short bar and short rod specimens was analyzed by the boundary integral equations method. This method makes use of boundary surface elements in obtaining the solution. The boundary integral models were composed of linear triangular and rectangular surface segments. Results were obtained for two specimens with width to thickness ratios of 1.45 and 2.00 and for different crack length to width ratios ranging from 0.4 to 0.7. Crack opening displacement and stress intensity factors determined from displacement calculations along the crack front and compliance calculations were compared with experimental values and with finite element analysis.
Epitaxial growth of aligned atomically precise chevron graphene nanoribbons on Cu(111).
Teeter, Jacob D; Costa, Paulo S; Mehdi Pour, Mohammad; Miller, Daniel P; Zurek, Eva; Enders, Axel; Sinitskii, Alexander
2017-07-25
Atomically precise chevron graphene nanoribbons (GNRs) have been synthesized on Cu(111) substrates by the surface-assisted coupling of 6,11-dibromo-1,2,3,4-tetraphenyltriphenylene (C 42 Br 2 H 26 ) and thermal cyclodehydrogenation of the resulting polymer. The GNRs form on Cu(111) epitaxially along the 〈112〉 crystallographic directions, which was found to be in agreement with the computational results, and at lower temperatures than on Au(111). This work demonstrates that the substrate plays an important role in the on-surface synthesis of GNRs and can result in new assembly modes of GNR structures.
Chevron osteotomy for the treatment of hallux valgus.
Horne, G; Tanzer, T; Ford, M
1984-03-01
Seventy-six chevron osteotomies with follow-up periods ranging from six months to eight years were reviewed. The majority of patients had pain over the bunion prior to operation, and 27 also presented with second metatarsalgia. After surgery there was a marked decrease of pain in the first metatarsophalangeal joint, and in 18 feet the second metatarsalgia was either eliminated or markedly decreased. Most patients were pleased with the appearance of the feet after surgery, but almost one-third of the women complained of difficulty in wearing high heels. The surgical technique is straightforward, but careful attention to detail is necessary to obtain a consistent and satisfactory result.
Li, Xigong; Sun, Junying; Lin, Xiangjin; Xu, Sanzhong; Tang, Tiansi
2013-06-01
The authors describe a modified double chevron subtrochanteric shortening osteotomy combined with cementless total hip arthroplasty for Crowe type-IV hip dysplasia. Shortening the femur allows to relax the shortened musculature. This operation was performed in 18 patients (22 hips) between January 2000 and February 2006. The mean follow-up period was 5.6 years (range: 3 to 8 years). The mean amount of femoral subtrochanteric shortening was 38 mm (range: 25 to 60 mm). The mean Harris hip score improved from 47 (range: 35 to 65) preoperatively to 88 points (range: 75 to 97) at final follow-up. The Trendelenburg sign was corrected from positive to negative in 12 of 22 hips. No acetabular or femoral components loosened or required revision during the follow-up period. All osteotomy sites healed in 3 to 6 months without complications. Cementless total hip arthroplasty using the modified double chevron subtrochanteric osteotomy provided good short- to midterm results in all 22 Crowe type-IV hip dislocations. Moreover, it restored the anatomic hip center and the limb length, which contributed to correction of the preoperative limp.
Park, H-W; Lee, K-B; Chung, J-Y; Kim, M-S
2013-04-01
Severe hallux valgus deformity is conventionally treated with proximal metatarsal osteotomy. Distal metatarsal osteotomy with an associated soft-tissue procedure can also be used in moderate to severe deformity. We compared the clinical and radiological outcomes of proximal and distal chevron osteotomy in severe hallux valgus deformity with a soft-tissue release in both. A total of 110 consecutive female patients (110 feet) were included in a prospective randomised controlled study. A total of 56 patients underwent a proximal procedure and 54 a distal operation. The mean follow-up was 39 months (24 to 54) in the proximal group and 38 months (24 to 52) in the distal group. At follow-up the hallux valgus angle, intermetatarsal angle, distal metatarsal articular angle, tibial sesamoid position, American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal score, patient satisfaction level, and complications were similar in each group. Both methods showed significant post-operative improvement and high levels of patient satisfaction. Our results suggest that the distal chevron osteotomy with an associated distal soft-tissue procedure provides a satisfactory method for correcting severe hallux valgus deformity.
Simulation of Strain Induced Pseudomagnetic Fields in Graphene Suspended on MEMS Chevron Actuators
NASA Astrophysics Data System (ADS)
Vutukuru, Mounika; Christopher, Jason; Bishop, David; Swan, Anna
Graphene has been shown to withstand remarkable levels of mechanical strain an order of magnitude larger than bulk crystalline materials. This exceptional stretchability of graphene allows for the direct tuning of fundamental material properties, as well as for the investigation of novel physics such as generation of strain induced pseudomagnetic fields. However, current methods for strain such as polymer elongation or pressurized wells do not integrate well into devices. We propose microelectromechanical (MEMS) Chevron actuators as a reliable platform for applying strain to graphene. In addition to their advantageous controllable output force, low input power and ease of integration into existing technologies, MEMS allow for different strain orientations to optimize pseudomagnetic field generation in graphene. Here, we model nonuniform strain in suspended graphene on Chevron actuators using COMSOL Multiphysics. By simulating the deformation of the graphene geometry under the device actuation, we explore the pseudomagnetic field map induced by numerically calculating the components of the strain tensor. Our models provide the theoretical framework with which experimental analysis is compared, and optimize our MEMS designs for further exploration of novel physics in graphene. The authors would like to thank NSF DMR 1411008 for their support on this project.
Approximate correlations for chevron-type plate heat exchangers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wanniarachchi, A.S.; Ratnam, U.; Tilton, B.E.
1995-12-31
There exists very little useful data representing the performance of industrial plate heat exchangers (PHEs) in the open literature. As a result, it has been difficult to arrive at any generalized correlations. While every PHE manufacturer is believed to have a comprehensive set of performance curves for their own designs, there exists the need to generate an approximate set of generalized correlations for the heat-transfer community. Such correlations can be used for preliminary designs and analytical studies. This paper attempts to develop such a set of generalized correlations to quantify the heat-transfer and pressure-drop performance of chevron-type PHEs. For thismore » purpose, the experimental data reported by Heavner et al. were used for the turbulent region. For the laminar region, a semi-theoretical approach was used to express, for example, the friction factor as a function of the Reynolds number and the chevron angle. Asymptotic curves were used for the transitional region. Physical explanations are provided for the trends shown by the generalized correlations. The correlations are compared against the open-literature data, where appropriate. These correlations are expected to be improved in the future when more data become available.« less
Jowett, Charlie R J; Bedi, Harvinder S
Minimally invasive surgery is increasing in popularity. It is relevant in hallux valgus surgery owing to the potential for reduced disruption of the soft tissues and improved wound healing. We present our results and assess the learning curve of the minimally invasive Chevron Akin operation for hallux valgus. A total of 120 consecutive feet underwent minimally invasive Chevron Akin for symptomatic hallux valgus, of which 14 were excluded. They were followed up for a mean of 25 (range 18 to 38) months. The patients were clinically assessed using the American Orthopaedic Foot and Ankle Society score. Complications and patient satisfaction were recorded. The radiographs were analyzed and measurements recorded for hallux valgus and intermetatarsal angle correction. The mean age of the patients undergoing surgery was 55 (range 25 to 81) years. Of the 78 patients, 76 (97.4%) were female and 2 (2.6%) were male; 28 (35.9%) cases were bilateral. The mean American Orthopaedic Foot and Ankle Society score improved from 56 (range 23 to 76) preoperatively to 87 (range 50 to 100) postoperatively (p < .001). The mean hallux valgus and intermetatarsal angles preoperatively were 29.7° (range 12° to 46°) and 14.0° (range 8° to 20°). The corresponding postoperative angles were 10.3° (range 0° to 25°) and 7.6° (range 3° to 15°; p < .001). The patients were satisfied with the results of surgery in 87% of cases (92 of 106). The incidence of reoperation was 14% (15 of 106). These are the only reported results for this technique. They display a steep associated learning curve. However, the results are promising, and the learning curve is comparable to that for open hallux valgus surgery. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Métivier, L.; Brossier, R.; Mérigot, Q.; Oudet, E.; Virieux, J.
2016-04-01
Full waveform inversion using the conventional L2 distance to measure the misfit between seismograms is known to suffer from cycle skipping. An alternative strategy is proposed in this study, based on a measure of the misfit computed with an optimal transport distance. This measure allows to account for the lateral coherency of events within the seismograms, instead of considering each seismic trace independently, as is done generally in full waveform inversion. The computation of this optimal transport distance relies on a particular mathematical formulation allowing for the non-conservation of the total energy between seismograms. The numerical solution of the optimal transport problem is performed using proximal splitting techniques. Three synthetic case studies are investigated using this strategy: the Marmousi 2 model, the BP 2004 salt model, and the Chevron 2014 benchmark data. The results emphasize interesting properties of the optimal transport distance. The associated misfit function is less prone to cycle skipping. A workflow is designed to reconstruct accurately the salt structures in the BP 2004 model, starting from an initial model containing no information about these structures. A high-resolution P-wave velocity estimation is built from the Chevron 2014 benchmark data, following a frequency continuation strategy. This estimation explains accurately the data. Using the same workflow, full waveform inversion based on the L2 distance converges towards a local minimum. These results yield encouraging perspectives regarding the use of the optimal transport distance for full waveform inversion: the sensitivity to the accuracy of the initial model is reduced, the reconstruction of complex salt structure is made possible, the method is robust to noise, and the interpretation of seismic data dominated by reflections is enhanced.
NASA Astrophysics Data System (ADS)
Wang, Liang-Wei; Liu, Yu-Nan; Lyu, Ping-Chiang; Jackson, Sophie E.; Hsu, Shang-Te Danny
2015-09-01
Understanding the mechanism by which a polypeptide chain thread itself spontaneously to attain a knotted conformation has been a major challenge in the field of protein folding. HP0242 is a homodimeric protein from Helicobacter pylori with intertwined helices to form a unique pseudo-knotted folding topology. A tandem HP0242 repeat has been constructed to become the first engineered trefoil-knotted protein. Its small size renders it a model system for computational analyses to examine its folding and knotting pathways. Here we report a multi-parametric study on the folding stability and kinetics of a library of HP0242 variants, including the trefoil-knotted tandem HP0242 repeat, using far-UV circular dichroism and fluorescence spectroscopy. Equilibrium chemical denaturation of HP0242 variants shows the presence of highly populated dimeric and structurally heterogeneous folding intermediates. Such equilibrium folding intermediates retain significant amount of helical structures except those at the N- and C-terminal regions in the native structure. Stopped-flow fluorescence measurements of HP0242 variants show that spontaneous refolding into knotted structures can be achieved within seconds, which is several orders of magnitude faster than previously observed for other knotted proteins. Nevertheless, the complex chevron plots indicate that HP0242 variants are prone to misfold into kinetic traps, leading to severely rolled-over refolding arms. The experimental observations are in general agreement with the previously reported molecular dynamics simulations. Based on our results, kinetic folding pathways are proposed to qualitatively describe the complex folding processes of HP0242 variants.
On the precision of experimentally determined protein folding rates and φ-values
De Los Rios, Miguel A.; Muralidhara, B.K.; Wildes, David; Sosnick, Tobin R.; Marqusee, Susan; Wittung-Stafshede, Pernilla; Plaxco, Kevin W.; Ruczinski, Ingo
2006-01-01
φ-Values, a relatively direct probe of transition-state structure, are an important benchmark in both experimental and theoretical studies of protein folding. Recently, however, significant controversy has emerged regarding the reliability with which φ-values can be determined experimentally: Because φ is a ratio of differences between experimental observables it is extremely sensitive to errors in those observations when the differences are small. Here we address this issue directly by performing blind, replicate measurements in three laboratories. By monitoring within- and between-laboratory variability, we have determined the precision with which folding rates and φ-values are measured using generally accepted laboratory practices and under conditions typical of our laboratories. We find that, unless the change in free energy associated with the probing mutation is quite large, the precision of φ-values is relatively poor when determined using rates extrapolated to the absence of denaturant. In contrast, when we employ rates estimated at nonzero denaturant concentrations or assume that the slopes of the chevron arms (mf and mu) are invariant upon mutation, the precision of our estimates of φ is significantly improved. Nevertheless, the reproducibility we thus obtain still compares poorly with the confidence intervals typically reported in the literature. This discrepancy appears to arise due to differences in how precision is calculated, the dependence of precision on the number of data points employed in defining a chevron, and interlaboratory sources of variability that may have been largely ignored in the prior literature. PMID:16501226
A first look at measurement error on FIA plots using blind plots in the Pacific Northwest
Susanna Melson; David Azuma; Jeremy S. Fried
2002-01-01
Measurement error in the Forest Inventory and Analysis work of the Pacific Northwest Station was estimated with a recently implemented blind plot measurement protocol. A small subset of plots was revisited by a crew having limited knowledge of the first crew's measurements. This preliminary analysis of the first 18 months' blind plot data indicates that...
WITHDRAWN: Interventions for treating hallux valgus (abductovalgus) and bunions.
Ferrari, Jill; Higgins, Julian Pt; Prior, Trevor D
2009-04-15
Hallux valgus is classified as an abnormal deviation of the great toe (hallux) towards the midline of the foot. To identify and evaluate the evidence from randomised trials of interventions used to correct hallux valgus. We searched the Cochrane Bone, Joint and Muscle Trauama Group trials register (2003/1), the Cochrane Central Register of Controlled Trials (The Cochrane Library issue 1, 2003), MEDLINE (January 1966 to March 2003) and EMBASE (1980 to January 2003). No language restrictions were applied. Hand searching of specific foot journals was also undertaken.Date of the most recent search: 31st March 2003. Randomised or quasi-randomised trials of both conservative and surgical treatments of hallux valgus. Excluded were studies comparing areas of surgery not specific to the control of the deformity such as use of anaesthetics or tourniquet placement. Methodological quality of trials which met the inclusion criteria was independently assessed by two reviewers. Data extraction was undertaken by two reviewers. The trials were grouped according to the interventions being compared, but the dissimilarity in the comparisons prevented pooling of results. The methodological quality of the 21 included trials was generally poor and trial sizes were small.Three trials involving 332 participants evaluated conservative treatments versus no treatment. There was no evidence of a difference in outcomes between treatment and no treatment.One good quality trial involving 140 participants compared surgery to conservative treatment. Evidence was shown of an improvement in all outcomes in patients receiving chevron osteotomy compared with those receiving orthoses. The same trial also compared surgery to no treatment in 140 participants. Evidence was shown of an improvement in all outcomes in patients receiving chevron osteotomy compared with those receiving no treatment.Two trials involving 133 people with hallux valgus compared Keller's arthroplasty with other surgical techniques. In general, there was no advantage or disadvantage using Keller's over the other techniques. When the distal osteotomy was compared to Keller's arthroplasty, the osteotomy showed evidence of improving the intermetatarsal angle and preserving joint range of motion. The arthroplasty was found to have less of an impact on walking ability compared to the arthrodesis.Six trials involving 309 participants compared chevron (and chevron-type) osteotomy with other techniques. The chevron osteotomy offered no advantages in these trials. For some outcomes, other techniques gave better results. Two of these trials (94 participants) compared a type of proximal osteotomy to a proximal chevron osteotomy and found no evidence of a difference in outcomes between techniques.Three trials involving 157 participants compared outcomes between original operations and surgeon's adaptations. There was no advantage found for any of the adaptations.Three trials involving 71 people with hallux valgus compared new methods of fixation to traditional methods. There was no evidence that the new methods of fixation were detrimental to the outcome of the patients.Four trials involving 162 participants evaluated methods of post-operative rehabilitation. The use of continuous passive motion appeared to give an improved range of motion and earlier recovery following surgery. Early weightbearing or the use of a crepe bandage were not found to be detrimental to final outcome. Only a few studies had considered conservative treatments. The evidence from these suggested that orthoses and night splints did not appear to be any more beneficial in improving outcomes than no treatment. Surgery (chevron osteotomy) was shown to be beneficial compared to orthoses or no treatment, but when compared to other osteotomies, no technique was shown to be superior to any other. Only one trial had compared an osteotomy to an arthroplasty. There was limited evidence to suggest that the osteotomy gave the better outcomes. It was notable that the numbers of participants in some trials remaining dissatisfied at follow-up were consistently high (25 to 33%), even when the hallux valgus angle and pain had improved. A few of the more recent trials used assessment scores that combine several aspects of the patients outcomes. These scoring systems are useful to the clinician when comparing techniques but are of dubious relevance to the patient if they do not address their main concern and such scoring systems are frequently unvalidated. Only one study simply asked the patient if they were better than before the treatment. Final outcomes were most frequently measured at one year, with a few trials maintaining follow-up for 3 years. Such time-scales are minimal given that the patients will be on their feet for at least another 20-30 years after treatment. Future research should include patient-focused outcomes, standardised assessment criteria and longer surveillance periods, more usefully in the region of 5-10 years.
Interventions for treating hallux valgus (abductovalgus) and bunions.
Ferrari, J; Higgins, J P T; Prior, T D
2004-01-01
Hallux valgus is classified as an abnormal deviation of the great toe (hallux) towards the midline of the foot. To identify and evaluate the evidence from randomised trials of interventions used to correct hallux valgus. We searched the Cochrane Musculoskeletal Injuries Group trials register (2003/1), the Cochrane Central Register of Controlled Trials (The Cochrane Library issue 1, 2003), MEDLINE (January 1966 to March 2003) and EMBASE (1980 to January 2003). No language restrictions were applied. Hand searching of specific foot journals was also undertaken. Date of the most recent search: 31st March 2003. Randomised or quasi-randomised trials of both conservative and surgical treatments of hallux valgus. Excluded were studies comparing areas of surgery not specific to the control of the deformity such as use of anaesthetics or tourniquet placement. Methodological quality of trials which met the inclusion criteria was independently assessed by two reviewers. Data extraction was undertaken by two reviewers. The trials were grouped according to the interventions being compared, but the dissimilarity in the comparisons prevented pooling of results. The methodological quality of the 21 included trials was generally poor and trial sizes were small. Three trials involving 332 participants evaluated conservative treatments versus no treatment. There was no evidence of a difference in outcomes between treatment and no treatment. One good quality trial involving 140 participants compared surgery to conservative treatment. Evidence was shown of an improvement in all outcomes in patients receiving chevron osteotomy compared with those receiving orthoses. The same trial also compared surgery to no treatment in 140 participants. Evidence was shown of an improvement in all outcomes in patients receiving chevron osteotomy compared with those receiving no treatment. Two trials involving 133 people with hallux valgus compared Keller's arthroplasty with other surgical techniques. In general, there was no advantage or disadvantage using Keller's over the other techniques. When the distal osteotomy was compared to Keller's arthroplasty, the osteotomy showed evidence of improving the intermetatarsal angle and preserving joint range of motion. The arthroplasty was found to have less of an impact on walking ability compared to the arthrodesis. Six trials involving 309 participants compared chevron (and chevron-type) osteotomy with other techniques. The chevron osteotomy offered no advantages in these trials. For some outcomes, other techniques gave better results. Two of these trials (94 participants) compared a type of proximal osteotomy to a proximal chevron osteotomy and found no evidence of a difference in outcomes between techniques. Three trials involving 157 participants compared outcomes between original operations and surgeon's adaptations. There was no advantage found for any of the adaptations. Three trials involving 71 people with hallux valgus compared new methods of fixation to traditional methods. There was no evidence that the new methods of fixation were detrimental to the outcome of the patients. Four trials involving 162 participants evaluated methods of post-operative rehabilitation. The use of continuous passive motion appeared to give an improved range of motion and earlier recovery following surgery. Early weightbearing or the use of a crepe bandage were not found to be detrimental to final outcome. Only a few studies had considered conservative treatments. The evidence from these suggested that orthoses and night splints did not appear to be any more beneficial in improving outcomes than no treatment. Surgery (chevron osteotomy) was shown to be beneficial compared to orthoses or no treatment, but when compared to other osteotomies, no technique was shown to be superior to any other. Only one trial had compared an osteotomy to an arthroplasty. There was limited evidence to suggest that the osteotomy gat the osteotomy gave the better outcomes. It was notable that the numbers of participants in some trials remaining dissatisfied at follow-up were consistently high (25 to 33%), even when the hallux valgus angle and pain had improved. A few of the more recent trials used assessment scores that combine several aspects of the patients outcomes. These scoring systems are useful to the clinician when comparing techniques but are of dubious relevance to the patient if they do not address their main concern and such scoring systems are frequently unvalidated. Only one study simply asked the patient if they were better than before the treatment. Final outcomes were most frequently measured at one year, with a few trials maintaining follow-up for 3 years. Such time-scales are minimal given that the patients will be on their feet for at least another 20-30 years after treatment. Future research should include patient-focused outcomes, standardised assessment criteria and longer surveillance periods, more usefully in the region of 5-10 years.
Restrepo-Pérez, Laura; Soler, Lluís; Martínez-Cisneros, Cynthia S.; Schmidt, Oliver G.
2014-01-01
We demonstrate that catalytic micromotors can be trapped in microfluidic chips containing chevron and heart-shaped structures. Despite the challenge presented by the reduced size of the traps, microfluidic chips with different trapping geometries can be fabricated via replica moulding. We prove that these microfluidic chips can capture micromotors without the need for any external mechanism to control their motion. PMID:24643940
Single-grain growth in Si film by chevron-shaped cw laser beam scanning
NASA Astrophysics Data System (ADS)
Yeh, Wenchang; Yamazaki, Satoki; Ishimoto, Akihisa; Morito, Shigekazu
2016-02-01
A single grain with a length of 450 µm and a width of 5-6 µm was grown in a 60 nm Si film on SiO2 by scanning a chevron-shaped cw laser beam, which was formed by passing a linear laser beam through a novel one-sided Dove prism. The crystal did not have any dominant orientations in both the growth and normal directions. The orientation rotated about the transverse direction at a rate of 0.47-0.51°/µm in the forward direction, which suggests that the lattice constant at the film surface was 0.049-0.053% larger than that at the film bottom.
Chevron v Echazabal: Protection, Opportunity, and Paternalism
Daniels, Norman
2003-01-01
The Supreme Court, in Chevron v Echazabal, ruled that risks to a disabled worker, if established by an individualized medical assessment, can disqualify the worker from protections offered by the Americans with Disabilities Act (ADA). This decision rejected the antipaternalist position of ADA advocates that workers with disabilities should be able to determine, through their own consent, the risks they will take. Such strong antipaternalism may not be compatible with the underlying justification for the protection of workers against health hazards. Stringent regulation of workplace hazards involves restricting the scope of consent to risk. Resolution of this conflict will depend on more careful examination of the degree to which individualized medical assessments avoid stereotyping and bias. PMID:12660194
Field calibration of orifice meters for natural gas flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ting, V.C.; Shen, J.J.S.
1989-03-01
This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6,4,2-in.) orifice meters conducted at the Chevron's Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27{sup 0}C (650 psig and 80{sup 0}F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibratemore » the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron's high Reynolds number test data taken at a large test facility in Venice, Louisiana. The test results also successfully demonstrate that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.« less
Effects of Droplet Size on Intrusion of Sub-Surface Oil Spills
NASA Astrophysics Data System (ADS)
Adams, Eric; Chan, Godine; Wang, Dayang
2014-11-01
We explore effects of droplet size on droplet intrusion and transport in sub-surface oil spills. Negatively buoyant glass beads released continuously to a stratified ambient simulate oil droplets in a rising multiphase plume, and distributions of settled beads are used to infer signatures of surfacing oil. Initial tests used quiescent conditions, while ongoing tests simulate currents by towing the source and a bottom sled. Without current, deposited beads have a Gaussian distribution, with variance increasing with decreasing particle size. Distributions agree with a model assuming first order particle loss from an intrusion layer of constant thickness, and empirically determined flow rate. With current, deposited beads display a parabolic distribution similar to that expected from a source in uniform flow; we are currently comparing observed distributions with similar analytical models. Because chemical dispersants have been used to reduce oil droplet size, our study provides one measure of their effectiveness. Results are applied to conditions from the `Deep Spill' field experiment, and the recent Deepwater Horizon oil spill, and are being used to provide ``inner boundary conditions'' for subsequent far field modeling of these events. This research was made possible by grants from Chevron Energy Technology Co., through the Chevron-MITEI University Partnership Program, and BP/The Gulf of Mexico Research Initiative, GISR.
The influence of geometry on jet plume development
NASA Astrophysics Data System (ADS)
Xia, H.; Tucker, P. G.; Eastwood, S.; Mahak, M.
2012-07-01
Our recent efforts of using large-eddy simulation (LES) type methods to study complex and realistic geometry single stream and co-flow nozzle jets and acoustics are summarized in this paper. For the LES, since the solver being used tends towards having dissipative qualities, the subgrid scale (SGS) model is omitted, giving a numerical type LES (NLES). To overcome near wall streak resolution problems a near wall RANS (Reynolds averaged Navier-Stokes) model is smoothly blended in the LES making a hybrid RANS-NLES approach. Several complex nozzle geometries including the serrated (chevron) nozzle, realistic co-axial nozzles with eccentricity, pylon and wing-flap are discussed. The hybrid RANS-NLES simulations show encouraging predictions for the chevron jets. The chevrons are known to increase the high frequency noise at high polar angles, but decrease the low frequency noise at lower angles. The deflection effect of the potential core has an important mechanism of noise reduction. As for co-axial nozzles, the eccentricity, the pylon and the deployed wing-flap are shown to influence the flow development, especially the former to the length of potential core and the latter two having a significant impact on peak turbulence levels and spreading rates. The studies suggest that complex and real geometry effects are influential and should be taken into count when moving towards real engine simulations.
Chevron beam dump for ITER edge Thomson scattering system.
Yatsuka, E; Hatae, T; Vayakis, G; Bassan, M; Itami, K
2013-10-01
This paper contains the design of the beam dump for the ITER edge Thomson scattering system and mainly concerns its lifetime under the harsh thermal and electromagnetic loads as well as tight space allocation. The lifetime was estimated from the multi-pulse laser-induced damage threshold. In order to extend its lifetime, the structure of the beam dump was optimized. A number of bent sheets aligned parallel in the beam dump form a shape called a chevron which enables it to avoid the concentration of the incident laser pulse energy. The chevron beam dump is expected to withstand thermal loads due to nuclear heating, radiation from the plasma, and numerous incident laser pulses throughout the entire ITER project with a reasonable margin for the peak factor of the beam profile. Structural analysis was also carried out in case of electromagnetic loads during a disruption. Moreover, detailed issues for more accurate assessments of the beam dump's lifetime are clarified. Variation of the bi-directional reflection distribution function (BRDF) due to erosion by or contamination of neutral particles derived from the plasma is one of the most critical issues that needs to be resolved. In this paper, the BRDF was assumed, and the total amount of stray light and the absorbed laser energy profile on the beam dump were evaluated.
Commercialization of the Chevron FCC vanadium trap
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, J.V.; Kuehler, C.W.; Krishna, A.S.
1995-09-01
Vanadium, present to varying degrees in FCC feed, deposits on the catalyst virtually quantitatively in the cracking process. In resid operations, vanadium levels on catalyst can reach 10,000 ppm at typical catalyst make-up rates. Once on the catalyst, vanadium destroys the zeolite and restricts access to active sites. This reduces catalyst activity. A vanadium trap is a material that when introduced into the catalyst inventory selectively reacts with migrating vanadium, thus protecting the zeolite and other active components of the catalyst. The trap may be incorporated into the catalyst, or introduced as a separate particle. Only a limited amount ofmore » trap can be incorporated into the catalyst without limiting the amount of zeolite that can be included. Gulf began development of a vanadium trap during the early 1980`s. The work produced a variety of promising materials whose use as vanadium traps was subsequently patented. The work ultimately led to a formulation with a phase very active for trapping vanadium while still quite sulfur tolerant. Based on these results, an extensive pilot plant evaluation was undertaken by Chevron after the Chevron-Gulf merger to better simulate commercial operation. The paper describes pilot plant tests as well as 3 commercial tests of this vanadium trap.« less
Early results using a biodegradable magnesium screw for modified chevron osteotomies.
Plaass, Christian; Ettinger, Sarah; Sonnow, Lena; Koenneker, Soeren; Noll, Yvonne; Weizbauer, Andreas; Reifenrath, Janin; Claassen, Leif; Daniilidis, Kiriakos; Stukenborg-Colsman, Christina; Windhagen, Henning
2016-12-01
This is the first larger study analyzing the use of magnesium-based screws for fixation of modified Chevron osteotomies in hallux valgus surgery. Forty-four patients (45 feet) were included in this prospective study. A modified Chevron osteotomy was performed on every patient and a magnesium screw used for fixation. The mean clinical follow up was 21.4 weeks. The mean age of the patients was 45.5 years. Forty patients could be provided with the implant, in four patients the surgeon decided to change to a standard metallic implant. The AOFAS, FAAM and pain NRS-scale improved markedly. The hallux valgus angle, intermetatarsal angle and sesamoid position improved significantly. Seven patients showed dorsal subluxation, rotation or medial shifting of the metatarsal heads within the first 3 months. One of these patients was revised, in all others the findings were considered clinically not significant or the patients refused revision. This study shows the feasibility of using magnesium screws in hallux valgus-surgery. Surgeons starting with the use of these implants should be aware of the proper handling of these implants and should know about corrosion effects during healing and its radiographic appearance. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2207-2214, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
The Influence of Specimen Type on Tensile Fracture Toughness of Rock Materials
NASA Astrophysics Data System (ADS)
Aliha, Mohammad Reza Mohammad; Mahdavi, Eqlima; Ayatollahi, Majid Reza
2017-03-01
Up to now, several methods have been proposed to determine the mode I fracture toughness of rocks. In this research, different cylindrical and disc shape samples, namely: chevron bend (CB), short rod (SR), cracked chevron notched Brazilian disc (CCNBD), and semi-circular bend (SCB) specimens were considered for investigating mode I fracture behavior of a marble rock. It is shown experimentally that the fracture toughness values of the tested rock material obtained from different test specimens are not consistent. Indeed, depending on the geometry and loading type of the specimen, noticeable discrepancies can be observed for the fracture toughness of a same rock material. The difference between the experimental mode I fracture resistance results is related to the magnitude and sign of T-stress that is dependent on the geometry and loading configuration of the specimen. For the chevron-notched samples, the critical value of T-stress corresponding to the critical crack length was determined using the finite element method. The CCNBD and SR specimens had the most negative and positive T-stress values, respectively. The dependency of mode I fracture resistance to the T-stress was shown using the extended maximum tangential strain (EMTSN) criterion and the obtained experimental rock fracture toughness data were predicted successfully with this criterion.
Screw Versus Plate Fixation for Chevron Osteotomy: A Retrospective Study.
Andrews, Boyd J; Fallat, Lawrence M; Kish, John P
2016-01-01
The chevron osteotomy is a popular procedure used for the correction of moderate hallux abducto valgus deformity. Fixation is typically accomplished with Kirschner wires or bone screws; however, in cystic or osteoporotic bone, these could be inadequate, resulting in displacement of the capital fragment. We propose using a locking plate and interfragmental screw for fixation of the chevron osteotomy that could reduce the healing time and decrease the incidence of displacement. We performed a retrospective cohort study for chevron osteotomies on 75 feet (73 patients). The control groups underwent fixation with 1 screw in 30 feet (40%) and 2 screws in 30 feet (40%). A total of 15 feet (20%) were included in the locking plate and interfragmental screw group. The patients were followed up until bone healing was achieved at a median of 7 (range 6 to 14) weeks. Our hypothesis was that those treated with the locking plate and interfragmental screw would have a faster healing time and fewer incidents of capital fragment displacement compared with the 1- or 2-screw groups. The corresponding mean intervals to healing for the 1-screw group was 7.71 ± 1.28 (range 6 to 10) weeks, for the 2-screw group was 7.27 ± 1.57 (range 6 to 14) weeks, and for the locking plate and interfragmental screw group was 7.01 ± 1.00 (range 6 to 9) weeks. One case of capital fragment displacement occurred in the single screw group and one in the 2-screw group. No displacement occurred in the locking plate and interfragmental screw group. Neither finding was statistically significant. However, we believe the locking plate and interfragmental screw could be a viable option in patients with osteoporotic and cystic bone changes for correction of hallux abducto valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Nakase, Yuen; Nakamura, Kei; Sougawa, Akira; Nagata, Tomoyuki; Mochizuki, Satoshi; Kitai, Shouzo; Inaba, Seishirou
2017-09-01
Large sheet-type surgical materials (e.g., absorbable hemostat, adhesion barrier membranes, and flat surgical mesh) are difficult to introduce into a corporeal cavity using a 5-mm trocar; however, laparoscopic surgeries that use mainly 5-mm trocars are increasing. Furthermore, it is necessary not only to introduce but also to secure the applied surgical material and expand it from the original surgical site. To address these challenges, we developed a novel procedure for introducing such surgical materials into a corporeal cavity using a 5-mm trocar and a self-expanding origami structure, called the "chevron pleats procedure (CPP)". We used CPP in 114 cases of laparoscopic surgery for gastrointestinal diseases. The chevron folding pattern is an excellent origami structure and compactly folds a large sheet of material for use with a slim trocar. Surgical materials were folded using a chevron pleats pattern and inserted into a novel, slim, long syringe-type device, which was made from a specially ordered precision polypropylene tube, for introduction into a corporeal cavity. When the surgical material was used, the end of the device was placed above the surgical site and the inner rod was pushed. The surgical material was securely injected and expanded over the surgical site. Surgical materials were introduced smoothly and securely using a 5-mm trocar to a site of intraoperative bleeding, the incisional surface of the liver, and defects of the abdominal wall or peritoneum. Efficient hemostasis was attained, the introduction and expansion of surgical mesh was made simpler, and the covering of defects of the peritoneum with adhesion barrier membranes, which is typically difficult during laparoscopic surgery, was easily performed. CPP is a basic utility procedure for introducing several sheet-type surgical materials into a corporeal cavity with a 5-mm trocar and might help ensure efficient and safe laparoscopic surgery.
Kim, Hyong-Nyun; Park, Yoo-Jung; Kim, Gab-Lae; Park, Yong-Wook
2013-01-01
The purpose of the present study was to investigate the outcomes of distal chevron osteotomy with lateral soft tissue release for moderate to severe hallux valgus. The patients were selected using criteria that included the degree of lateral soft tissue contracture and metatarsocuneiform joint flexibility. The contracture and flexibility were determined from intraoperative varus stress radiographs. From April 2007 to May 2009, 56 feet in 51 consecutive patients with moderate to severe hallux valgus had undergone distal chevron osteotomy with lateral soft tissue release. This was done when the lateral soft tissue contracture was not so severe that passive correction of the hallux valgus deformity was not possible and when the metatarsocuneiform joint was flexible enough to permit additional correction of the first intermetatarsal angle after lateral soft tissue release. The mean patient age was 45.2 (range 23 to 54) years, and the duration of follow-up was 27.5 (range 24 to 46) months. The mean hallux abductus angle decreased from 33.5° ± 3.1° to 11.6° ± 3.3°, and the first intermetatarsal angle decreased from 16.4° ± 2.7° to 9.7° ± 2.1°. The mean American Orthopaedic Foot and Ankle Society hallux-interphalangeal scores increased from 66.6° ± 10.7° to 92.6° ± 9.4° points, and 46 of the 51 patients (90%) were either very satisfied or satisfied with the outcome. No recurrence of deformity or osteonecrosis of the metatarsal head occurred. When lateral soft tissue contracture is not severe and when the metatarsocuneiform joint is flexible enough, distal chevron osteotomy with lateral soft tissue release can be a useful and effective choice for moderate to severe hallux valgus deformity. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Full-scale flight tests of aircraft morphing structures using SMA actuators
NASA Astrophysics Data System (ADS)
Mabe, James H.; Calkins, Frederick T.; Ruggeri, Robert T.
2007-04-01
In August of 2005 The Boeing Company conducted a full-scale flight test utilizing Shape Memory Alloy (SMA) actuators to morph an engine's fan exhaust to correlate exhaust geometry with jet noise reduction. The test was conducted on a 777-300ER with GE-115B engines. The presence of chevrons, serrated aerodynamic surfaces mounted at the trailing edge of the thrust reverser, have been shown to greatly reduce jet noise by encouraging advantageous mixing of the free, and fan streams. The morphing, or Variable Geometry Chevrons (VGC), utilized compact, light weight, and robust SMA actuators to morph the chevron shape to optimize the noise reduction or meet acoustic test objectives. The VGC system was designed for two modes of operation. The entirely autonomous operation utilized changes in the ambient temperature from take-off to cruise to activate the chevron shape change. It required no internal heaters, wiring, control system, or sensing. By design this provided one tip immersion at the warmer take-off temperatures to reduce community noise and another during the cooler cruise state for more efficient engine operation, i.e. reduced specific fuel consumption. For the flight tests a powered mode was added where internal heaters were used to individually control the VGC temperatures. This enabled us to vary the immersions and test a variety of chevron configurations. The flight test demonstrated the value of SMA actuators to solve a real world aerospace problem, validated that the technology could be safely integrated into the airplane's structure and flight system, and represented a large step forward in the realization of SMA actuators for production applications. In this paper the authors describe the development of the actuator system, the steps required to integrate the morphing structure into the thrust reverser, and the analysis and testing that was required to gain approval for flight. Issues related to material strength, thermal environment, vibration, electrical power, controls, data acquisition, and engine operability are discussed. Furthermore the authors layout a road map for the next stage of development of SMA aerospace actuators. A detailed look at the requirements and specifications that may define a production SMA actuator and the technology development required to meet them are presented. A path for meeting production requirements and achieving the next level of technology readiness for both autonomous and controlled SMA actuators is proposed. This path relies strongly on cross functional and organizational teaming including industry, academia, and government.
Postoperative pain and preemptive local anesthetic infiltration in hallux valgus surgery.
Gądek, Artur; Liszka, Henryk; Wordliczek, Jerzy
2015-03-01
Several techniques of anesthesia are used in foot surgery. Preemptive analgesia helps to prevent the development of hypersensitivity in the perioperative period. The aim of our study was to assess the role of preemptive local anesthetic infiltration and postoperative pain after hallux valgus surgery. We evaluated 118 patients who underwent modified chevron and mini-invasive Mitchell-Kramer bunionectomy of the first distal metatarsal. After spinal anesthesia each patient randomly received an infiltration of local anesthetic or the same amount of normal saline 10 minutes before the skin incision. We measured the intensity of pain 4, 8, 12, 16, 24, and 72 hours after the release of the tourniquet using a visual analogue scale (VAS). Rescue analgesia and all other side effects were noted. Preemptive analgesia resulted in less pain during the first 24 hours after surgery. The decrease of VAS score was significantly lower in the study group during all the short postoperative periods measured. The rescue analgesia was administered in 11.9% of patients in the injected group and 42.4% in the placebo group (P < .05). In the injected group we did not observe significant difference in VAS score between patients post-chevron and miniinvasive Mitchell-Kramer osteotomy of the first distal metatarsal. No systemic adverse effects were noted. One persistent injury of dorsomedial cutaneous nerve was observed. Preemptive local anesthetic infiltration was an efficient and safe method to reduce postoperative pain after hallux valgus surgery. The analgesic effect was satisfactory in both traditional and minimally invasive techniques. © The Author(s) 2014.
Kosová, Klára; Chrpová, Jana; Šantrůček, Jiří; Hynek, Radovan; Štěrbová, Lenka; Vítámvás, Pavel; Bradová, Jana; Prášil, Ilja Tom
2017-10-03
Fusarium head blight (FHB) disease adversely affects grain quality and final yield in small-grain cereals including barley. In the present study, the effect of an artificial infection with Fusarium culmorum and an application of deoxynivalenol (DON) on barley spikes of cultivars Chevron and Pedant during flowering was investigated at grain mid-dough stage (BBCH 73) 10days after pathogen inoculation (10 dai). Proteomic analysis using a two-dimensional differential gel electrophoresis (2D-DIGE) technique coupled with LC-MS/MS investigated 98 protein spots revealing quantitative or qualitative differences between the experimental variants. Protein functional annotation of 93 identified protein spots revealed that most affected functional groups represent storage proteins (globulins, hordeins), followed by proteins involved in carbohydrate metabolism (α-amylase inhibitor, β-amylase, glycolytic enzymes), amino acid metabolism (aminotransferases), defence response (chitinase, xylanase inhibitor, serpins, SGT1, universal stress protein USP), protein folding (chaperones, chaperonins), redox metabolism (ascorbate-glutathione cycle), and proteasome-dependent protein degradation. The obtained results indicate adverse effects of infection on plant proteome as well as an active plant response to pathogen as shown by enhanced levels of several inhibitors of pathogen-produced degradation enzymes (α-amylase inhibitor, xylanase inhibitor, serpins), chaperones, and other stress-related proteins (SGT1, USP). Genotypic differences were found in hordein abundance between Chevron and Pedant. Copyright © 2017 Elsevier B.V. All rights reserved.
Chevron beam dump for ITER edge Thomson scattering system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yatsuka, E.; Hatae, T.; Bassan, M.
This paper contains the design of the beam dump for the ITER edge Thomson scattering system and mainly concerns its lifetime under the harsh thermal and electromagnetic loads as well as tight space allocation. The lifetime was estimated from the multi-pulse laser-induced damage threshold. In order to extend its lifetime, the structure of the beam dump was optimized. A number of bent sheets aligned parallel in the beam dump form a shape called a chevron which enables it to avoid the concentration of the incident laser pulse energy. The chevron beam dump is expected to withstand thermal loads due tomore » nuclear heating, radiation from the plasma, and numerous incident laser pulses throughout the entire ITER project with a reasonable margin for the peak factor of the beam profile. Structural analysis was also carried out in case of electromagnetic loads during a disruption. Moreover, detailed issues for more accurate assessments of the beam dump's lifetime are clarified. Variation of the bi-directional reflection distribution function (BRDF) due to erosion by or contamination of neutral particles derived from the plasma is one of the most critical issues that needs to be resolved. In this paper, the BRDF was assumed, and the total amount of stray light and the absorbed laser energy profile on the beam dump were evaluated.« less
NASA Technical Reports Server (NTRS)
Kenny, Patrick
2004-01-01
The Acoustics Branch is responsible for reducing noise levels for jet and fan components on aircraft engines. To do this, data must be measured and calibrated accurately to ensure validity of test results. This noise reduction is accomplished by modifications to hardware such as jet nozzles, and by the use of other experimental hardware such as fluidic chevrons, elliptic cores, and fluidic shields. To insure validity of data calibration, a variety of software is used. This software adjusts the sound amplitude and frequency to be consistent with data taken on another day. Both the software and the hardware help make noise reduction possible. work properly. These software programs were designed to make corrections for atmosphere, shear, attenuation, electronic, and background noise. All data can be converted to a one-foot lossless condition, using the proper software corrections, making a reading independent of weather and distance. Also, data can be transformed from model scale to full scale for noise predictions of a real flight. Other programs included calculations of Over All Sound Pressure Level (OASPL), Effective Perceived Noise Level (EPNL). OASPL is the integration of sound with respect to frequency, and EPNL is weighted for a human s response to different sound frequencies and integrated with respect to time. With the proper software correction, data taken in the NATR are useful in determining ways to reduce noise. display any difference between two or more data files. Using this program and graphs of the data, the actual and predicted data can be compared. This software was tested on data collected at the Aero Acoustic Propulsion Laboratory (AAPL) using a variety of window types and overlaps. Similarly, short scripts were written to test each individual program in the software suite for verification. Each graph displays both the original points and the adjusted points connected with lines. During this summer, data points were taken during a live experiment at the AAPL to measure Nozzle Acoustic Test Rig (NATR) background noise levels. Six condenser microphones were placed in strategic locations around the dome and the inlet tunnel to measure different noise sources. From the control room the jet was monitored with the help of video cameras and other sensors. The data points were recorded, reduced, and plotted, and will be used to plan future modifications to the NATR. The primary goal to create data reduction test programs and provide verification was completed. As a result of the internship, I learned C/C++, UNIX/LINUX, Excel, and acoustic data processing methods. I also recorded data at the AAPL, then processed and plotted it. These data would be useful to compare against existing data. In addition, I adjusted software to work on the Mac OSX platform. And I used the available training resources.
Workers’ Liberty, Workers’ Welfare: The Supreme Court Speaks on the Rights of Disabled Employees
Bayer, Ronald
2003-01-01
On June 10, 2002, a unanimous US Supreme Court rejected the claim by Mario Echazabal that he had been denied his rights under the Americans with Disabilities Act when Chevron USA had refused to employ him because he had hepatitis C. Chevron believed that Echazabal’s exposure to hepatotoxic chemicals in its refinery would pose a grave risk to his health. This case poses critical questions about the ethics of public health: When, if ever, is paternalism justified? Must choice always trump other values? What ought to be the balance between welfare and liberty? Strikingly, the groups that came to Echazabal’s defense adopted an antipaternalistic posture fundamentally at odds with the ethical foundations of occupational health and safety policy. PMID:12660193
Russia joins Kazakh/Omani pipeline venture group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-08-03
Russia has agreed to become a founding partner in a joint venture pipeline project formed by Kazakhstan and Oman. The agreement, signed in Bermuda July 24, is related to Chevron Corp.'s further development of supergiant Tengiz and Korolev fields along the Caspian Sea coast in Kazakhstan. Azerbaijan last month signed an agreement to become a founding member of the group, accepting terms agreed to by original joint venturers Kazakhstan and Oman. Azerbaijan's new government still must formally ratify its agreement. In addition, Chevron in June signed a memorandum of understanding to join the group at a future date. This papermore » reports that each of the founding members holds an equal interest in Caspian Pipeline Consortium Ltd., which will operate as a limited liability company incorporated in Bermuda.« less
Weil, Lowell; Consul, Devon
2015-07-01
A tailor's bunion or bunionette deformity is a combination of osseous and soft tissue bursitis on the lateral aspect of the fifth metatarsal head. This article discusses 7 corrective measures: medial oblique sliding osteotomy with fixation, medial oblique slide osteotomy-minimal incision procedure without fixation, SERI (simple, effective, rapid, inexpensive) with fixation, chevron with or without fixation, closing, lateral wedge osteotomy at the metatarsal neck or proximal diaphysis, Weil osteotomy, and scarfette. These evidence-based techniques can be used by practitioners for medical management of their patients through evaluation, diagnosis, and prognosis. Complications are also addressed. Copyright © 2015 Elsevier Inc. All rights reserved.
Modeling post-fire woody carbon dynamics with data from remeasured inventory plots
Bianca N.I. Eskelson; Jeremy Fried; Vicente Monleon
2015-01-01
In California, the Forest Inventory and Analysis (FIA) plots within large fires were visited one year after the fire occurred resulting in a time series of measurements before and after fire. During this additional plot visit, the standard inventory measurements were augmented for these burned plots to assess fire effects. One example of the additional measurements is...
Madison Avenue vs. the Environmentalists
ERIC Educational Resources Information Center
Sandman, Peter M.
1973-01-01
The Chevron F-310 advertising program is studied as an example of large companies' use of environmental and conservation themes for attracting customers. The effects of such advertising on the society are discussed. (JP)
75 FR 49486 - Environmental Impacts Statements; Notice Of Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-13
..., CA, Chevron Energy Solutions Lucerne Valley Solar Project, Proposing To Develop a 45-megawatt (MW) Solar Photovotaic (PV) Plant and Associated Facilities on 516 Acres of Federal Land Managed, California...
78 FR 20089 - Sunshine Act Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
... recommendations to the Board Members based on the CSB's investigation into a hydrocarbon release and fire that... determined that nineteen Chevron employees were engulfed in a vapor cloud formed by the hydrocarbon release...
Publications - GMC 131 | Alaska Division of Geological & Geophysical
and core from the Chevron USA Inc. Eagle Creek #1 well Authors: Unknown Publication Date: 1989 Inc. Eagle Creek #1 well: Alaska Division of Geological & Geophysical Surveys Geologic Materials
75 FR 7479 - Environmental Impact Statements; Notice of Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-19
... EIS, BLM, CA Chevron Energy Solutions Lucerne Valley Solar Project, Proposing To Develop a 45-megawatt (MW) Solar Photovoltaic (PV) Plant and Associated Facilities on 516 Acres of Federal Land Managed...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, A.
Cyclohexane buyers, hit by a string of US plant closures, are breathing a sigh of relief at signs of an upswing in capacity. Phillips Petroleum has assured the future of a cyclohexane plant at its Guayama, PR site, while Kerr-McGee Chemical has confirmed it will acquire a mothballed 30-million gal/year unit from Unocal and restart it. Phillips deal is connected to an agreement to license Chevron Chemical's Aromax catalytic reforming technology for its Guayama refinery. The technology, which will cut the company's aromatics production costs, secures the future of Phillips petrochemical operations at the site, including the downstream 90-million gal/yearmore » cyclohexane plant. The Chevron process is said to boost yields of benzene, toluene, and xylene above those of conventional reforming processes. It relies on a zeolite catalyst to convert light paraffins into aromatics; conventional reforming converts higher-valued aromatic naphthas.« less
NASA Astrophysics Data System (ADS)
Smith, Samuel; Llinas, Juan-Pablo; Bokor, Jeffrey; Salahuddin, Sayeef
2018-01-01
Ballistic quantum transport calculations based on the non-equilbrium Green's function formalism show that field-effect transistor devices made from chevron-type graphene nanoribbons (CGNRs) could exhibit negative differential resistance with peak-to-valley ratios in excess of 4800 at room temperature as well as steep-slope switching with 6 mV/decade subtheshold swing over five orders of magnitude and ON-currents of 88$\\mu$A/$\\mu$m. This is enabled by the superlattice-like structure of these ribbons that have large periodic unit cells with regions of different effective bandgap, resulting in minibands and gaps in the density of states above the conduction band edge. The CGNR ribbon used in our proposed device has been previously fabricated with bottom-up chemical synthesis techniques and could be incorporated into an experimentally-realizable structure.
A modified Austin/chevron osteotomy for treatment of hallux valgus and hallux rigidus.
Vasso, Michele; Del Regno, Chiara; D'Amelio, Antonio; Schiavone Panni, Alfredo
2016-03-01
The purpose of this brief paper is to present the preliminary results of a modified Austin/chevron osteotomy for treatment of hallux valgus and hallux rigidus. In this procedure, the dorsal arm of the osteotomy is performed orthogonal to the horizontal plane of the first metatarsal, the main advantage being that this allows much easier and more accurate multiplanar correction of first metatarsal deformities. From 2010 to 2013, 184 consecutive patients with symptomatic hallux valgus and 48 patients with hallux rigidus without severe metatarsophalangeal joint degeneration underwent such modified chevron osteotomy. Mean patient age was 54.9 (range 21-70) years, and mean follow-up duration was 41.7 (range 24-56) months. Ninety-three percent of patients were satisfied with the surgery. Mean American Orthopaedic Foot and Ankle Society (AOFAS) score improved from 56.6 preoperatively to 90.6 at last follow-up, and mean visual analog scale (VAS) pain score decreased from 5.7 preoperatively to 1.6 at final follow-up (p < 0.05). In patients treated for hallux valgus, mean hallux valgus angle decreased from 34.1° preoperatively to 6.2° at final follow-up, and mean intermetatarsal angle decreased from 18.5° preoperatively to 4.1° at final follow-up (p < 0.05). One patient developed postoperative transfer metatarsalgia, treated successfully with second-time percutaneous osteotomy of the minor metatarsals, whilst one patient had wound infection that resolved with systemic antibiotics. Level IV.
Murphy, Ryan M; Fallat, Lawrence M; Kish, John P
2014-01-01
The distal chevron osteotomy is a widely accepted technique for the treatment of hallux abductovalgus deformity. Although the osteotomy is considered to be stable, displacements of the capital fragment has been described. We propose a new method for fixation of the osteotomy involving the axial loading screw (ALS) used in addition to single screw fixation. We believe this method will provide a more mechanically stable construct. We reviewed the charts of 46 patients in whom 52 feet underwent a distal chevron osteotomy that was fixated with either 1 screw or 2 screws that included the ALS. We hypothesized that the ALS group would have fewer displacements and would heal more quickly than the single screw fixation group. We found that the group with ALS fixation had healed at a mean of 6.5 weeks and that the group with single screw fixation had healed at 9.53 weeks (p = .001). Also, 8 cases occurred of displacement of the capital fragment in the single screw, control group compared with 2 cases of displacement in the ALS group. However, this finding was not statistically significant. The addition of the ALS to single screw fixation allowed the patients to heal approximately 3 weeks earlier than single screw fixation alone. The ALS is a fixation option for the surgeon to consider when osseous correction of hallux abducto valgus is performed. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Fracture toughness versus micro-tensile bond strength testing of adhesive-dentin interfaces.
De Munck, Jan; Luehrs, Anne-Katrin; Poitevin, André; Van Ende, Annelies; Van Meerbeek, Bart
2013-06-01
To assess interfacial fracture toughness of different adhesive approaches and compare to a standard micro-tensile bond-strength (μTBS) test. Chevron-notched beam fracture toughness (CNB) was measured following a modified ISO 24370 standard. Composite bars with dimensions of 3.0×4.0×25 mm were prepared, with the adhesive-dentin interface in the middle. At the adhesive-dentin interface, a chevron notch was prepared using a 0.15 mm thin diamond blade mounted in a water-cooled diamond saw. Each specimen was loaded until failure in a 4-point bend test setup and the fracture toughness was calculated according to the ISO specifications. Similarly, adhesive-dentin micro-specimens (1.0×1.0×8-10 mm) were stressed in tensile until failure to determine the μTBS. A positive correlation (r(2)=0.64) was observed between CNB and μTBS, which however was only nearly statistically significant, mainly due to the dissimilar outcome of Scotchbond Universal (3M ESPE). While few μTBS specimens failed at the adhesive-dentin interface, almost all CNB specimens failed interfacially at the notch tip. Weibull moduli for interfacial fracture toughness were much higher than for μTBS (3.8-11.5 versus 2.7-4.8, respectively), especially relevant with regard to early failures. Although the ranking of the adhesives on their bonding effectiveness tested using CNB and μTBS corresponded well, the outcome of CNB appeared more reliable and less variable. Fracture toughness measurement is however more laborious and requires specific equipment. The μTBS nevertheless appeared to remain a valid method to assess bonding effectiveness in a versatile way. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Mariano Lake Mine: Technical Reports
This Final Removal Site Evaluation describes the objectives, work performed, and results of a Removal Site Evaluation (RSE) at the Mariano Lake Mine, which was performed by ARCADIS U.S., Inc. on behalf of Chevron Environmental Management Company.
Atmospheric Science Data Center
2014-05-15
... shades of red. The distinctive chevron shape of the Mojave Desert is bordered by the San Andreas Fault on the south and the Garlock Fault ... March 14, 2000 - Southern California with the Mojave Desert and surrounding area. project: MISR ...
76 FR 41302 - Request for Certification of Compliance-Rural Industrialization Loan and Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-13
... venture involving a Chevron gas station, Burger King Restaurant, McAlister's Deli and a convenience store... (gasoline stations with convenience stores) and 722211 (limited-service restaurants). DATES: All interested...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-17
... Cyanamid Company); Hubbard Hall, Inc.; Invesys, Inc. on behalf of Elmwood Sensors, Inc.; Chevron..., subsidiaries and divisions; BP Products North America, Inc.; Eastern Color & Chemical Company. Dated: June 3...
Publications - GMC 214 | Alaska Division of Geological & Geophysical
Chevron USA Inc. OCS Y-0996-1 (Diamond #1) well Authors: Unknown Publication Date: 1993 Publisher: Alaska see our publication sales page for more information. Bibliographic Reference Unknown, 1993, Vitrinite
Research yields precise uncertainty equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E.H.; Ferguson, K.R.
1987-08-03
Results of a study of orifice-meter accuracy by Chevron Oil Field Research Co. at its Venice, La., calibration facility have important implications for natural gas custody-transfer measurement. The calibration facility, data collection, and equipment calibration were described elsewhere. This article explains the derivation of uncertainty factors and details the study's findings. The results were based on calibration of two 16-in. orifice-meter runs. The experimental data cover a beta-ratio range of from 0.27 to 0.71 and a Reynolds number range of from 4,000,000 to 35,000,000. Discharge coefficients were determined by comparing the orifice flow to the flow from critical-flow nozzles.
Solitons induced by alternating electric fields in surface-stabilized ferroelectric liquid crystals
NASA Astrophysics Data System (ADS)
Jeżewski, W.; Kuczyński, W.; Hoffmann, J.
2011-04-01
Propagation of solitary waves activated in thin ferroelectric liquid crystal cells under external, sinusoidally alternating electric fields is investigated using the electro-optic technique. It is shown that solitons give contributions only to the loss component of the response spectrum, within rather narrow ranges of frequencies and in sufficiently strong fields. The limit frequency, at which the amplitude of the velocity of the solitary waves is greatest, is found to be related to material constants of liquid crystals. Measuring this threshold frequency provides the capability to determine the elastic constant of surface stabilized liquid crystalline materials in the bookshelf or chevron layer geometries.
Conceptual recurrence plots: revealing patterns in human discourse.
Angus, Daniel; Smith, Andrew; Wiles, Janet
2012-06-01
Human discourse contains a rich mixture of conceptual information. Visualization of the global and local patterns within this data stream is a complex and challenging problem. Recurrence plots are an information visualization technique that can reveal trends and features in complex time series data. The recurrence plot technique works by measuring the similarity of points in a time series to all other points in the same time series and plotting the results in two dimensions. Previous studies have applied recurrence plotting techniques to textual data; however, these approaches plot recurrence using term-based similarity rather than conceptual similarity of the text. We introduce conceptual recurrence plots, which use a model of language to measure similarity between pairs of text utterances, and the similarity of all utterances is measured and displayed. In this paper, we explore how the descriptive power of the recurrence plotting technique can be used to discover patterns of interaction across a series of conversation transcripts. The results suggest that the conceptual recurrence plotting technique is a useful tool for exploring the structure of human discourse.
Hallux Valgus Correction Comparing Percutaneous Chevron/Akin (PECA) and Open Scarf/Akin Osteotomies.
Lee, Moses; Walsh, James; Smith, Margaret M; Ling, Jeff; Wines, Andrew; Lam, Peter
2017-08-01
Minimally invasive surgery is being used increasingly, including for hallux valgus surgery. Despite the growing interest in minimally invasive procedures, there have been few publications on percutaneous chevron/akin (PECA) procedures, and no studies have been published comparing PECA to open scarf/akin osteotomies (SA). This was a prospective, randomized study of 50 patients undergoing operative correction of hallux valgus using one of 2 techniques (PECA vs open SA). Data were collected preoperatively and on 1 day, 2 weeks, 6 weeks, and 6 months postoperatively. Outcome measures include the American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal (AOFAS-HMI) Score, visual analog pain score, hallux valgus angle (HVA), and 1-2 intermetatarsal angle (IMA). Twenty-five patients underwent PECA procedures and 25 patients received SA procedures. Both groups showed significantly improved AOFAS-HMI scores after surgery (PECA group: 61.8 to 88.9, SA group: 57.3 to 84.1, P = .560) with comparable final scores. HVA and IMA also presented similar outcomes at final follow-up ( P = .520 and P = .270, respectively). However, the PECA group showed significantly lower pain level (VAS) in the early postoperative phase (postoperative day 1 to postoperative week 6, P < .001 and P = .004, respectively). No serious complications were observed in either group. Both groups showed comparable good to excellent clinical and radiologic outcomes at final follow-up. However, the PECA group had significantly less pain in the first 6 weeks following surgery. Level of Evidence Level II, prospective comparative study.
Rippled Surfaces on a Slope in Coloe Fossae
2014-01-09
This observation from NASA Mars Reconnaissance Orbiter shows a set of landforms that appears to form a nested chevron pattern on a slope in Coloe Fossae. Interestingly, nearby surfaces on the same slope are all parallel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuehler, C.W.
This paper reports on the need for specialty fluid catalytic cracking (FCC) additives which is likely to increase, given the refining environment and the arrival of reformulated gasoline prompted by the most recent national environmental laws. C.W. Kuehler of Chevron Research and Technology Co., U.S.A. covered the participants in the field and the state of FCC additive technology this past June at Akzo Chemie's catalysts symposium in Scheveningen, The Netherlands. Other authors of the paper presented were A.S. Krishna, C.R. Hsieh, A.R.English, and T.A. Pecoraro, all with Chevron. The FCC process has undergone numerous changes in its 50-year history, Kuehlermore » pointed out. It shows the impressive continual growth of the process. One important aspect of additives is their ability to alter and control the nature of the FCC catalyst, thereby controlling the reactions carried out in the reactor and regenerator.« less
Impact of Air Injection on Jet Noise
NASA Technical Reports Server (NTRS)
Henderson, Brenda; Norum, Tom
2007-01-01
The objective of this viewgraph presentation is to review the program to determine impact of core fluidic chevrons on noise produced by dual stream jets (i.e., broadband shock noise - supersonic, and mixing noise - subsonic and supersonic). The presentation reviews the sources of jet noise. It shows designs of Generation II Fluidic Chevrons. The injection impacts shock structure and stream disturbances through enhanced mixing. This may impact constructive interference between acoustic sources. The high fan pressures may inhibit mixing produced by core injectors. A fan stream injection may be required for better noise reduction. In future the modification of Gen II nozzles to allow for some azimuthal control: will allow for higher mass flow rates and will allow for shallower injection angles A Flow field study is scheduled for spring, 2008 The conclusions are that injection can reduce well-defined shock noise and injection reduces mixing noise near peak jet noise angle
Long-term tree inventory data from mountain forest plots in France.
Fuhr, Marc; Cordonnier, Thomas; Courbaud, Benoît; Kunstler, Georges; Mermin, Eric; Riond, Catherine; Tardif, Pascal
2017-04-01
We present repeated tree measurement data from 63 permanent plots in mountain forests in France. Plot elevations range from 800 (lower limit of the montane belt) to 1942 m above sea level (subalpine belt). Forests mainly consist of pure or mixed stands dominated by European beech (Fagus sylvatica), Silver fir (Abies alba), and Norway spruce (Picea abies), in association with various broadleaved species at low elevation and with Arolla pine (Pinus cembra) at high elevation. The plot network includes 23 plots in stands that have not been managed for the last 40 years (at least) and 40 plots in plots managed according to an uneven-aged system with single-tree or small-group selection cutting. Plot sizes range from 0.2 to 1.9 ha. Plots were installed from 1994 to 2004 and remeasured two to five times during the 1994-2015 period. During the first census (installation), living trees more than 7.5 cm in dbh were identified, their diameter at breast height (dbh) was measured and their social status (strata) noted. Trees were spatially located, either with x, y, and z coordinates (40 plots) or within 0.25-ha square subplots (23 plots). In addition, in a subset of plots (58 plots), tree heights and tree crown dimensions were measured on a subset of trees and dead standing trees and stumps were included in the census. Remeasurements after installation include live tree diameters (including recruited trees), tree status (living, damaged, dead, stump), and for a subset of trees, height. At the time of establishment of the plots, plot densities range from 181 to 1328 stems/ha and plot basal areas range from 13.6 to 81.3 m 2 /ha. © 2017 by the Ecological Society of America.
Rolling Resistance of Light Truck Tires
DOT National Transportation Integrated Search
1981-01-01
The supplement contains carpet plots of 44 light truck tires giving rolling resistance versus load and reciprocal of inflation pressure. The plots represent measured data. To avoid the expense of taking measurements at all points on the plots, an equ...
Park, Chul-Hyun; Ahn, Ji-Yong; Kim, Yu-Mi; Lee, Woo-Chun
2013-06-01
The purpose of this study was to compare the results of hallux valgus surgery between feet fixed with Kirschner wires and those fixed with a plate and screws. Between December 2008 and November 2009, 53 patients (62 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. Thirty-four patients (41 feet) were stabilised with Kirschner wires (K-wire group) and 19 patients (21 feet) were stabilised with a locking plate (plate group). Clinical results were assessed using American Orthopaedic Foot and Ankle Society (AOFAS) score. Radiographic parameters were compared between these groups. Recurrence rate at the last follow-up was compared between the K-wire and plate groups. Mean AOFAS score was lower in the plate group, however, the difference between the groups was not statistically significant in AOFAS score at the last follow-up. Hallux valgus angle and intermetatarsal angle were significantly larger in the plate group at the last follow-up. Mean 1-2 metatarsal (MT) distance on immediately postoperative radiographs was significant larger in the plate group. Four (9.8 %) of the 41 feet in the K-wire group and 7 (33.3 %) of the 21 feet in the plate group showed hallux valgus recurrence at the last follow-up. The plate group had a significantly higher risk of recurrence than the K-wire group. Fixation of proximal chevron osteotomy using a plate and screws has a greater risk of hallux valgus recurrence than fixation using Kirschner wires.
Energy insurance for Anchorage, Alaska - Beluga river gas field, Cook Inlet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, N.D.; Lindblom, R.G.
1987-05-01
The Beluga River gas field is the primary energy source for Anchorage, Alaska. The field is located 40 mi west of Anchorage astride the northwest shoreline of the Cook Inlet. Gas was discovered in December 1962 by Chevron's Beluga River unit (BRU) 1 well in section 35, T13N, R10W, S.B. and M. There are 16 producing wells in the field capable of a total gas potential of 140,000 MCFD. The current production averages 75,000 MCFD and the field has produced 220 BCF gas. Chevron, Shell, and ARCO have equal interests in the field. The Beluga River unit was formed inmore » 1962 with Chevron as operator. The produced gas is sold to the Chugach Electric Company and the Enstar Gas Company, both Anchorage-based utilities. The gas accumulation is trapped by a doubly plunging, slightly asymmetric anticlinal fold trending northeast-southwest. Gas is found from 3000 to 6000 ft vertical depth in sands within the lower Sterling (Pliocene) and Beluga River (upper Miocene) Formations. Reservoir sands range in thickness from 5 to 85 ft with average porosities of 24 to 30%. The Sterling sands were deposited in broad sand channels in a fluvial-deltaic setting, whereas Beluga sands were deposited in a high-energy fluvial environment in shifting stream courses. The use of the wireline repeat formation tester has aided in correlation, evaluation, and management of the multiple sand reservoirs. New gas sand reservoirs and partly depleted reservoirs are recognized, enabling completion from reservoirs of similar pressures and reducing risks associated with cross flow between reservoirs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Verma, Puneet; Casey, Dan
This report summarizes the work conducted under U.S. Department of Energy (US DOE) contract DE-FC36-04GO14286 by Chevron Technology Ventures (CTV, a division of Chevron U.S.A., Inc.), Hyundai Motor Company (HMC), and UTC Power (UTCP, a United Technologies company) to validate hydrogen (H2) infrastructure technology and fuel cell hybrid vehicles. Chevron established hydrogen filling stations at fleet operator sites using multiple technologies for on-site hydrogen generation, storage, and dispensing. CTV constructed five demonstration stations to support a vehicle fleet of 33 fuel cell passenger vehicles, eight internal combustion engine (ICE) vehicles, three fuel cell transit busses, and eight internal combustion enginemore » shuttle busses. Stations were operated between 2005 and 2010. HMC introduced 33 fuel cell hybrid electric vehicles (FCHEV) in the course of the project. Generation I included 17 vehicles that used UTCP fuel cell power plants and operated at 350 bar. Generation II included 16 vehicles that had upgraded UTC fuel cell power plants and demonstrated options such as the use of super-capacitors and operation at 700 bar. All 33 vehicles used the Hyundai Tucson sports utility vehicle (SUV) platform. Fleet operators demonstrated commercial operation of the vehicles in three climate zones (hot, moderate, and cold) and for various driving patterns. Fleet operators were Southern California Edison (SCE), AC Transit (of Oakland, California), Hyundai America Technical Center Inc. (HATCI), and the U.S. Army Tank Automotive Research, Development and Engineering Center (TARDEC, in a site agreement with Selfridge Army National Guard Base in Selfridge, Michigan).« less
Anchor enhanced capsulorraphy in bunionectomies using an L-shaped capsulotomy.
Gould, John S; Ali, Sheriff; Fowler, Rachel; Fleisig, Glenn S
2003-01-01
The objective of this study was to investigate potential benefit of a suture anchor-enhanced capsulorraphy in the early maintenance of correction in bunionectomies. We compared, retrospectively, in successive series, the loss of correction of the Hallux Valgus (HV) and intermetatarsal (IM) angle, in those repaired with an L-shaped capsulorraphy enhanced with anchors to those without. Intraoperative and second week postoperative simulated weightbearing anterior posterior (AP) X-rays were used to evaluate results. By using only intraoperative and early postoperative X-rays, we should have effectively eliminated extraneous factors that might have influenced our results. A Total of 106 cases were investigated, 65 of which were repaired using anchors, the remaining 41 without. In the anchor group, 38 underwent a proximal metatarsal concentric shelf osteotomy (CSO)/modified McBride procedure, while the remaining 27 had a distal Chevron correction. In the without-anchor group, 21 had a CSO/modified McBride procedure while 20 underwent the Chevron procedure. In the without-anchor group, the average HV and IM loss of correction was 4.60 degrees (range, -2 to 21 degrees) and 0.6 degrees (range, -1 to 9 degrees) respectively. In the anchor group, the corresponding loss was 2.8 degrees (range, -3 to 17 degrees) and 0.6 degrees (range, -2 to 14 degrees) respectively. These results, when statistically analyzed, demonstrated that while the IM angle change was not statistically significant, the HV angle change was statistically significant, implying that the anchor plays a significant role in maintaining the surgical correction in both the distal Chevron and CSO/ modified McBride bunionectomies.
Saugel, Bernd; Grothe, Oliver; Wagner, Julia Y
2015-08-01
When comparing 2 technologies for measuring hemodynamic parameters with regard to their ability to track changes, 2 graphical tools are omnipresent in the literature: the 4-quadrant plot and the polar plot recently proposed by Critchley et al. The polar plot is thought to be the more advanced statistical tool, but care should be taken when it comes to its interpretation. The polar plot excludes possibly important measurements from the data. The polar plot transforms the data nonlinearily, which may prevent it from being seen clearly. In this article, we compare the 4-quadrant and the polar plot in detail and thoroughly describe advantages and limitations of each. We also discuss pitfalls concerning the methods to prepare the researcher for the sound use of both methods. Finally, we briefly revisit the Bland-Altman plot for the use in this context.
J. A. Blackard; M. V. Finco; E. H. Helmer; G. R. Holden; M. L. Hoppus; D.M. Jacobs; A. J. Lister; G. G. Moisen; M. D. Nelson; R. Riemann; B. Ruefenacht; D. Salajanu; D. L. Weyermann; K. C. Winterberger; T. J. Brandeis; R. L. Czaplewski; R. E. McRoberts; P. L. Patterson; R. P. Tymcio
2008-01-01
A spatially explicit dataset of aboveground live forest biomass was made from ground measured inventory plots for the conterminous U.S., Alaska and Puerto Rico. The plot data are from the USDA Forest Service Forest Inventory and Analysis (FIA) program. To scale these plot data to maps, we developed models relating field-measured response variables to plot attributes...
NASA Astrophysics Data System (ADS)
Polotto, Franciele; Drigo Filho, Elso; Chahine, Jorge; Oliveira, Ronaldo Junio de
2018-03-01
This work developed analytical methods to explore the kinetics of the time-dependent probability distributions over thermodynamic free energy profiles of protein folding and compared the results with simulation. The Fokker-Planck equation is mapped onto a Schrödinger-type equation due to the well-known solutions of the latter. Through a semi-analytical description, the supersymmetric quantum mechanics formalism is invoked and the time-dependent probability distributions are obtained with numerical calculations by using the variational method. A coarse-grained structure-based model of the two-state protein Tm CSP was simulated at a Cα level of resolution and the thermodynamics and kinetics were fully characterized. Analytical solutions from non-equilibrium conditions were obtained with the simulated double-well free energy potential and kinetic folding times were calculated. It was found that analytical folding time as a function of temperature agrees, quantitatively, with simulations and experiments from the literature of Tm CSP having the well-known 'U' shape of the Chevron Plots. The simple analytical model developed in this study has a potential to be used by theoreticians and experimentalists willing to explore, quantitatively, rates and the kinetic behavior of their system by informing the thermally activated barrier. The theory developed describes a stochastic process and, therefore, can be applied to a variety of biological as well as condensed-phase two-state systems.
Protein Folding Mechanism of the Dimeric AmphiphysinII/Bin1 N-BAR Domain
Gruber, Tobias; Balbach, Jochen
2015-01-01
The human AmphyphisinII/Bin1 N-BAR domain belongs to the BAR domain superfamily, whose members sense and generate membrane curvatures. The N-BAR domain is a 57 kDa homodimeric protein comprising a six helix bundle. Here we report the protein folding mechanism of this protein as a representative of this protein superfamily. The concentration dependent thermodynamic stability was studied by urea equilibrium transition curves followed by fluorescence and far-UV CD spectroscopy. Kinetic unfolding and refolding experiments, including rapid double and triple mixing techniques, allowed to unravel the complex folding behavior of N-BAR. The equilibrium unfolding transition curve can be described by a two-state process, while the folding kinetics show four refolding phases, an additional burst reaction and two unfolding phases. All fast refolding phases show a rollover in the chevron plot but only one of these phases depends on the protein concentration reporting the dimerization step. Secondary structure formation occurs during the three fast refolding phases. The slowest phase can be assigned to a proline isomerization. All kinetic experiments were also followed by fluorescence anisotropy detection to verify the assignment of the dimerization step to the respective folding phase. Based on these experiments we propose for N-BAR two parallel folding pathways towards the homodimeric native state depending on the proline conformation in the unfolded state. PMID:26368922
Viseu, Maria Isabel; Melo, Eduardo P.; Carvalho, Teresa Isabel; Correia, Raquel F.; Costa, Sílvia M. B.
2007-01-01
The β→α transition of β-lactoglobulin, a globular protein abundant in the milk of several mammals, is investigated in this work. This transition, induced by the cationic surfactant dodecyltrimethylammonium chloride (DTAC), is accompanied by partial unfolding of the protein. In this work, unfolding of bovine β-lactoglobulin in DTAC is compared with its unfolding induced by the chemical denaturant guanidine hydrochloride (GnHCl). The final protein states attained in the two media have quite different secondary structure: in DTAC the α-helical content increases, leading to the so-called α-state; in GnHCl the amount of ordered secondary-structure decreases, resulting in a random coil-rich final state (denatured, or D, state). To obtain information on both mechanistic routes, in DTAC and GnHCl, and to characterize intermediates, the kinetics of unfolding were investigated in the two media. Equilibrium and kinetic data show the partial accumulation of an on-pathway intermediate in each unfolding route: in DTAC, an intermediate (I1) with mostly native secondary structure but loose tertiary structure appears between the native (β) and α-states; in GnHCl, another intermediate (I2) appears between states β and D. Kinetic rate constants follow a linear Chevron-plot representation in GnHCl, but show a more complex mechanism in DTAC, which acts like a stronger binding species. PMID:17693475
Fracture Toughness of Thin Plates by the Double-Torsion Test Method
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Radovic, Miladin; Lara-Curzio, Edgar; Nelson, George
2006-01-01
Double torsion testing can produce fracture toughness values without crack length measurement that are comparable to those measured via standardized techniques such as the chevron-notch, surface-crack-in-flexure and precracked beam if the appropriate geometry is employed, and the material does not exhibit increasing crack growth resistance. Results to date indicate that 8 < W/d < 80 and L/W > 2 are required if crack length is not considered in stress intensity calculations. At L/W = 2, the normalized crack length should be 0.35 < a/L < 0.65; whereas for L/W = 3, 0.2 < a/L < 0.75 is acceptable. In addition, the load-points need to roll to reduce friction. For an alumina exhibiting increasing crack growth resistance, values corresponding to the plateau of the R-curve were measured. For very thin plates (W/d > 80) nonlinear effects were encountered.
77 FR 43614 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
... (``LDAR'') for hazardous air pollutants, 40 CFR Part 63, Subparts A, H and CC, at an asphalt petroleum... penalty. In addition, although the plant has not refined asphalt since 2008, Chevron agrees to implement...
FACILITY 858, PORTION OF NORTHEAST SIDE (APRON AVENUE SIDE), SHOWING ...
FACILITY 858, PORTION OF NORTHEAST SIDE (APRON AVENUE SIDE), SHOWING CHEVRON DESIGN OVER FORMER PASSAGEWAY, OBLIQUE VIEW FACING WEST. - Schofield Barracks Military Reservation, Quadrangle K Barracks Type, Between Wilson Street & Capron Avenue near Williston Avenue, Wahiawa, Honolulu County, HI
FACILITY 859, DETAIL OF SOUTHWEST SIDE (WILSON STREET SIDE), SHOWING ...
FACILITY 859, DETAIL OF SOUTHWEST SIDE (WILSON STREET SIDE), SHOWING CHEVRON DESIGN OVER FORMER PASSAGEWAY, VIEW FACING NORTHEAST. - Schofield Barracks Military Reservation, Quadrangle K Barracks Type, Between Wilson Street & Capron Avenue near Williston Avenue, Wahiawa, Honolulu County, HI
Publications - GMC 129 | Alaska Division of Geological & Geophysical
DGGS GMC 129 Publication Details Title: Visual kerogen and TAI data of select cuttings and core from , Visual kerogen and TAI data of select cuttings and core from the Chevron USA Inc. Akulik #1 well: Alaska
Mariano Lake Mine is located in the Mariano Lake Chapter of the Navajo Nation, approximately 25 miles east of Gallup, N.M in McKinley County. EPA is working with Navajo Nation Environmental Protection Agency (NNEPA) to oversee cleanup work by Chevron U.S.A
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-29
... underground storage tank (UST) facilities; failure to perform annual tests of automatic line leak detectors... detectors for piping on the UST systems. CHEVRON also agrees under the Consent Decree to install dispenser...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
... Holdings, L.P.; New York State Electric & Gas Corporation; Notice of Baseline Filings August 24, 2010. Take... above submitted their baseline filing of its Statement of Operating Conditions for services provided...
Stabilometer "S" value study on asphalt concrete samples.
DOT National Transportation Integrated Search
1985-07-01
During the late fall of 1969 a study was made to determine the precision when testing asphalt concrete specimens for the Hveem stabilometer ("S") value (AASHTO T 246). Fifty samples, using Chevron 85-100 asphalt cement and aggregate from Walling Sand...
CO2 and CH4 Fluxes across Polygon Geomorphic Types, Barrow, Alaska, 2006-2010
Tweedie,Craig; Lara, Mark
2014-09-17
Carbon flux data are reported as Net Ecosystem Exchange (NEE), Gross Ecosystem Exchange (GEE), Ecosystem Respiration (ER), and Methane (CH4) flux. Measurements were made at 82 plots across various polygon geomorphic classes at research sites on the Barrow Environmental Observatory (BEO), the Biocomplexity Experiment site on the BEO, and the International Biological Program (IBP) site a little west of the BEO. This product is a compilation of data from 27 plots as presented in Lara et al. (2012), data from six plots presented in Olivas et al. (2010); and from 49 plots described in (Lara et al. 2014). Measurements were made during the peak of the growing seasons during 2006 to 2010. At each of the measurement plots (except Olivas et al., 2010) four different thicknesses of shade cloth were used to generate CO2 light response curves. Light response curves were used to normalize photosynthetically active radiation that is diurnally variable to a peak growing season average ~400 umolm-2sec-1. At the Olivas et al. (2010) plots, diurnal patterns were characterized by repeated sampling. CO2 measurements were made using a closed-chamber photosynthesis system and CH4 measurements were made using a photo-acoustic multi-gas analyzer. In addition, plot-level measurements for thaw depth (TD), water table depth (WTD), leaf area index (LAI), and normalized difference vegetation index (NDVI) are summarized by geomorphic polygon type.
Sylvio Mannel; Mark A. Rumble; Maribeth Price; Thomas M. Juntti; Dong Hua
2006-01-01
Many aspects of ecological research require measurement of characteristics within plots. Often, the time spent establishing plots is small relative to the time spent collecting and recording data. However, some studies require larger numbers of plots, where the time spent establishing the plot is consequential to the field effort. In open habitats, circular plots are...
Measurement of surface water runoff from plots of two different sizes
NASA Astrophysics Data System (ADS)
Joel, Abraham; Messing, Ingmar; Seguel, Oscar; Casanova, Manuel
2002-05-01
Intensities and amounts of water infiltration and runoff on sloping land are governed by the rainfall pattern and soil hydraulic conductivity, as well as by the microtopography and soil surface conditions. These components are closely interrelated and occur simultaneously, and their particular contribution may change during a rainfall event, or their effects may vary at different field scales. The scale effect on the process of infiltration/runoff was studied under natural field and rainfall conditions for two plot sizes: small plots of 0·25 m2 and large plots of 50 m2. The measurements were carried out in the central region of Chile in a piedmont most recently used as natural pastureland. Three blocks, each having one large plot and five small plots, were established. Cumulative rainfall and runoff quantities were sampled every 5 min. Significant variations in runoff responses to rainfall rates were found for the two plot sizes. On average, large plots yielded only 40% of runoff quantities produced on small plots per unit area. This difference between plot sizes was observed even during periods of continuous runoff.
Variations of measured and simulated soil-loss amounts in a semiarid area in Turkey.
Hacisalihoğlu, Sezgin
2010-06-01
The main goal of this research was soil-loss determination and comparison of the plot measurement results with simulation model (universal soil loss equation (USLE)) results in different land use and slope classes. The research took place in three different land-use types (Scotch pine forest, pasture land, and agricultural land) and in two different slope classes (15-20%, 35-40%). Within six measurement stations (for each land-use type and slope class-one station), totally 18 measurement plots have been constituted, and soil-loss amount measurements have been investigated during the research period (3 years along). USLE simulation model is used in these measurement plots for calculation the soil-loss amounts. The results pointed out that measured (in plots) and simulated (with USLE) soil-loss amounts differ significantly in each land-use type and slope class.
Flow-Field Surveys for Rectangular Nozzles
NASA Technical Reports Server (NTRS)
Zaman, K. B. M. Q.
2012-01-01
Flow field survey results for three rectangular nozzles are presented for a low subsonic condition obtained primarily by hot-wire anemometry. The three nozzles have aspect ratios of 2:1, 4:1 and 8:1. A fourth case included has 2:1 aspect ratio with chevrons added to the long edges. Data on mean velocity, turbulent normal and shear stresses as well as streamwise vorticity are presented covering a streamwise distance up to sixteen equivalent diameters from the nozzle exit. These detailed flow properties, including initial boundary layer characteristics, are usually difficult to measure in high speed flows and the primary objective of the study is to aid ongoing and future computational and noise modeling efforts.
NASA Astrophysics Data System (ADS)
Silva, Vinicius N. H.; Babilotte, Philippe; Rivet, Sylvain; Dubreuil, Mathieu; Le Jeune, Bernard; Dupont, Laurent
2012-12-01
We investigated the layer dynamics of a conventional surface-stabilized ferroelectric liquid crystal (SSFLC) using a full-optical snapshot Mueller matrix polarimeter (SMMP) based on wavelength polarization coding. Time-resolved polarimetric measurements were performed with different SSFLC samples, and a strong correlation between the polarimetric parameters and the SSFLC under electric field at different exposure times was found. It has been shown that the SMMP polarimeter is able to determine the evolution of the trajectory of the liquid crystal director between the two addressed states, the reversible motion of the smectic layer while switching, as well as the irreversible transition from chevron to bookshelf texture.
Lack of training threatening drilling talent supply
DOE Office of Scientific and Technical Information (OSTI.GOV)
Von Flatern, R.
When oil prices crashed in the mid-1980s, the industry tightened budgets. Among the austerity measures taken to survive the consequences of low product prices was an end to expensive, long-term investment training of drilling engineers. In the absence of traditional sources of trained drilling talent, forward-looking contractors are creating their own training programs. The paper describes the activities of some companies who are setting up their own training programs, and an alliance being set up by Chevron and Amoco for training. The paper also discusses training drilling managers, third-party trainers, and the consequences for the industry that does not renewmore » its inventory of people.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-03
... remain under review through July 31, 2013, which is the period that the ATPA is in effect: Ecuador--Human Rights Watch Ecuador--U.S./Labor Education in the Americas Project Ecuador--Chevron Texaco. Douglas Bell...
DOT National Transportation Integrated Search
1980-10-01
The experimental feature of this project was to evaluate the application and performance of Chevron Industrial Membrane applied to the tops of steel deck stringers and other similar members as corrosion protection in conjunction with the deck replace...
40 CFR 62.3852 - Identification of sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Emissions from Existing Phosphate Fertilizer Plants § 62.3852 Identification of sources. (a) The plan applies to existing facilities at the following phosphate fertilizer plants: (1) Agrico Chemical Company, Fort Madison, Iowa. (2) Chevron Chemical Company, Fort Madison, Iowa. (3) Occidental Chemical Company...
40 CFR 62.3852 - Identification of sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Emissions from Existing Phosphate Fertilizer Plants § 62.3852 Identification of sources. (a) The plan applies to existing facilities at the following phosphate fertilizer plants: (1) Agrico Chemical Company, Fort Madison, Iowa. (2) Chevron Chemical Company, Fort Madison, Iowa. (3) Occidental Chemical Company...
40 CFR 62.3852 - Identification of sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emissions from Existing Phosphate Fertilizer Plants § 62.3852 Identification of sources. (a) The plan applies to existing facilities at the following phosphate fertilizer plants: (1) Agrico Chemical Company, Fort Madison, Iowa. (2) Chevron Chemical Company, Fort Madison, Iowa. (3) Occidental Chemical Company...
The build-up of the cD halo of M 87: evidence for accretion in the last Gyr
NASA Astrophysics Data System (ADS)
Longobardi, A.; Arnaboldi, M.; Gerhard, O.; Mihos, J. C.
2015-07-01
Aims: We present kinematic and photometric evidence for an accretion event in the halo of the cD galaxy M 87 in the last Gyr. Methods: Using velocities for ~300 planetary nebulas (PNs) in the M 87 halo, we identify a chevron-like substructure in the PN phase-space. We implement a probabilistic Gaussian mixture model to identify PNs that belong to the chevron. From analysis of deep V-band images of M 87, we find that the region with the highest density of chevron PNs is a crown-shaped substructure in the light. Results: We assign a total of NPN,sub = 54 to the substructure, which extends over ~50 kpc along the major axis where we also observe radial variations of the ellipticity profile and a colour gradient. The substructure has highest surface brightness in a 20 kpc × 60 kpc region around 70 kpc in radius. In this region, the substructure causes an increase in surface brightness by ≳60%. The accretion event is consistent with a progenitor galaxy with a V-band luminosity of L = 2.8±1.0×109 L⊙ ,V, a colour of (B - V) = 0.76±0.05, and a stellar mass of M = 6.4±2.3×109 M⊙. Conclusions: The accretion of this progenitor galaxy has caused an important modification of the outer halo of M 87 in the last Gyr. This result provides strong evidence that the galaxy's cD halo is growing through the accretion of smaller galaxies as predicted by hierarchical galaxy evolution models. Based on observations made with the VLT at Paranal Observatory under programme 088.B-0288(A) and 093.B-066(A), and with the Subaru Telescope under programme S10A-039.
Impact of Fluidic Chevrons on Jet Noise
NASA Technical Reports Server (NTRS)
Henderson, Brenda S.; Kinzie, Kevin W.; Whitmire, Julia; Abeysinghe, Amal
2005-01-01
The impact of alternating fluidic core chevrons on the production of jet noise is investigated. Core nozzles for a representative 1/9th scale, bypass ratio 5 model system were manufactured with slots cut near the trailing edges to allow for air injection into the core and fan streams. The injectors followed an alternating pattern around the nozzle perimeter so that the injection alternated between injection into the core stream and injection into the fan stream. For the takeoff condition and a forward flight Mach number of 0.10, the overall sound pressure levels at the peak jet noise angle decrease with increasing injection pressure. Sound pressure levels increase for observation angles less than 110o at higher injection pressures due to increases in high frequency noise. Greater increases in high frequency noise are observed when the number of injectors increases from 8 to 12. When the forward flight Mach number is increased to 0.28, jet noise reduction (relative to the baseline) is observed at aft angles for increasing injection pressure while significant increases in jet noise are observed at forward observation angles due to substantial acoustic radiation at high frequencies. A comparison between inflow and alternating injectors shows that, for equal mass injection rates, the inflow nozzle produces greater low frequency noise reduction (relative to the baseline) than the alternating injectors at 90o and aft observation angles and a forward flight Mach number of 0.28. Preliminary computational fluid dynamic simulations indicate that the spatial decay rate of the hot potential core flow is less for the inflow nozzle than for the alternating nozzles which indicates that gentle mixing may be preferred over sever mixing when fluidic chevrons are used for jet noise reduction.
NASA Astrophysics Data System (ADS)
Lestari, W. D.; Ismail, R.; Jamari, J.; Bayuseno, A. P.
2017-05-01
Surface texture is a common method for improving wear properties of a tribo-pair of soft and hard bearing material. The reduction of wear rates on the contacting surface material is becoming important issues. In the present study, analysis of the contact pressure on the flat surface of UHMWPE (Ultra High Molecular Weight Polyethylene) under the static- and rolling motion with the surface of steel ball used the 3D finite element method (FEM) (the ABAQUS software version 6.12). Five shaped-texture models (square, circle, ellipse, triangle, and chevron) were presented on the flat surface for analysis. The normal load of 17, 30 and 50 N was deliberately set-up for static and rolling contact analysis. The contact pressure was determined to predict the wear behavior of the shaped-texture on the flat surface of UHMWPE. The results have shown that the static normal load yielded the lowest von-Mises stress distribution on the shaped-texture of the ellipse for all values applied a load, while the square shape experienced the highest stress distribution. Under rolling contact, however, the increasing load yielded the increasing von Mises stress distribution for the texture with a triangle shape. Moreover, the texture shapes for circle, ellipse, and chevron respectively, may undergo the lowest stress distribution for all load. The wear calculation provided that the circle and square shape may undergo the highest wear rates. Obviously, the surface texture of circle, ellipse, and chevron may experience the lowest wear rates and is potential for use in the surface engineering of bearing materials.
Lucas y Hernandez, J; Golanó, P; Roshan-Zamir, S; Darcel, V; Chauveaux, D; Laffenêtre, O
2016-03-01
The aim of this study was to report a single surgeon series of consecutive patients with moderate hallux valgus managed with a percutaneous extra-articular reverse-L chevron (PERC) osteotomy. A total of 38 patients underwent 45 procedures. There were 35 women and three men. The mean age of the patients was 48 years (17 to 69). An additional percutaneous Akin osteotomy was performed in 37 feet and percutaneous lateral capsular release was performed in 22 feet. Clinical and radiological assessments included the type of forefoot, range of movement, the American Orthopedic Foot and Ankle (AOFAS) score, a subjective rating and radiological parameters. The mean follow-up was 59.1 months (45.9 to 75.2). No patients were lost to follow-up. The mean AOFAS score increased from 62.5 (30 to 80) pre-operatively to 97.1 (75 to 100) post-operatively. A total of 37 patients (97%) were satisfied. At the last follow up there was a statistically significant decrease in the hallux valgus angle, the intermetatarsal angle and the proximal articular set angle. The range of movement of the first metatarsophalangeal joint improved significantly.. There was more improvement in the range of movement in patients who had fixation of the osteotomy of the proximal phalanx. Preliminary results of this percutaneous approach are promising. This technique is reliable and reproducible. Its main asset is that it maintains an excellent range of movement. The PERC osteotomy procedure is an effective approach for surgical management of moderate hallux valgus which combines the benefits of percutaneous surgery with the versatility of the chevron osteotomy whilst maintaining excellent first MTPJ range of motion. ©2016 The British Editorial Society of Bone & Joint Surgery.
Comparative performance study of smart structure for thermal microactuators
NASA Astrophysics Data System (ADS)
Yahya, Zulkarnain; Johar, Muhammad Akmal
2017-04-01
Thermal microactuator is one of earliest types of microactuators. Typical thermal actuators are in the form of Bimorph and Chevron structures. A bimorph thermal actuator has a complex movement direction, in arc motion and thus it is not feasible in the most MEMS designs. While Chevron actuator has a tendency to produce an off-plane movement which lead to low precision in lateral movement. A new thermal actuator design in the form of serpentine structures shows promising feature to have better performances in terms of more predictive lateral movement with smaller off-plane displacement. In MEMS chip design, areas play a critical role as it will impact with the cost of the final product. In this study, four different structures of thermal actuator were simulated using ANSYS v15. Three different set of area sizes which are 240 µm x 1000 µm, 240 µm x 1500 µm and 240 µm x 2000 µm have been analyzed. All four structures were named as Serpentine01, Serpentine02, Bimorph and Chevron. The data with regards to temperature produced by the structure and z-axis directional deformation were collected and analyzed. This paper reported the investigation result of comparison between these three types of thermal actuator structures design with a given area. From all of the result obtained, it is shown that the area 240 µm x 1500 µm showed a well balance performance in term of huge deformations and low power consumption. The Serpentine01 structure produced 16.7 µm deformation at 4mA of current. The results shows the potential of Serpentine01 structure as a new candidate for thermal microactuator for MEMS applications.
Active Flow Effectors for Noise and Separation Control
NASA Technical Reports Server (NTRS)
Turner, Travis L.
2011-01-01
New flow effector technology for separation control and enhanced mixing is based upon shape memory alloy hybrid composite (SMAHC) technology. The technology allows for variable shape control of aircraft structures through actively deformable surfaces. The flow effectors are made by embedding shape memory alloy actuator material in a composite structure. When thermally actuated, the flow effector def1ects into or out of the flow in a prescribed manner to enhance mixing or induce separation for a variety of applications, including aeroacoustic noise reduction, drag reduction, and f1ight control. The active flow effectors were developed for noise reduction as an alternative to fixed-configuration effectors, such as static chevrons, that cannot be optimized for airframe installation effects or variable operating conditions and cannot be retracted for off-design or fail-safe conditions. Benefits include: Increased vehicle control, overall efficiency, and reduced noise throughout all f1ight regimes, Reduced flow noise, Reduced drag, Simplicity of design and fabrication, Simplicity of control through direct current stimulation, autonomous re sponse to environmental heating, fast re sponse, and a high degree of geometric stability. The concept involves embedding prestrained SMA actuators on one side of the chevron neutral axis in order to generate a thermal moment and def1ect the structure out of plane when heated. The force developed in the host structure during def1ection and the aerodynamic load is used for returning the structure to the retracted position. The chevron design is highly scalable and versatile, and easily affords active and/or autonomous (environmental) control. The technology offers wide-ranging market applications, including aerospace, automotive, and any application that requires flow separation or noise control.
A partnership in upstream HSE technology transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olszewski, R.E. Wahjosoedibjo, A.S.; Hunley, M.; Peargin, J.C.
1996-11-01
The oil and gas industry was for nearly two decades the dominant force in the Indonesian economy and the single largest contributor to the nation`s development. Because of the success of Indonesia`s long-term development and diversification program, this once-dominant sector today occupies a more equal but still vital position in a better-balanced economy. The Indonesian government understands the danger to the environment posed by rapid industrial expansion and has enacted laws and regulations to ensure the sustainable development of its resources while protecting its rain forest environment. In 1992, the government oil company approached Chevron and Texaco for assistance inmore » training its Health, Safety, and Environment (HSE) professionals. The upstream environment, health and safety training program was developed to transfer HSE knowledge and technology to PERTAMINA, PT Caltex Pacific Indonesia, a C&T affiliate, and indirectly, to the entire Indonesian oil and gas industry and government ministries. The four companies have demonstrated the effectiveness of a partnership approach in developing and carrying out HSE training. During 1994 and 1995, four groups, each consisting of about twenty representatives from PERTAMINA, the Directorate of Oil and Gas (MIGAS), the Indonesian Environmental Impact Management Agency (BAPEDAL), CPI, and Chevron and Texaco worldwide subsidiaries, traveled to the United States for an intensive four-month program of study in HSE best practices and technology conducted by Chevron and Texaco experts. This paper describes the development and realization of The PERTAMINA/CPI Health, Safety and Environment Training Program, outlines subjects covered and explains the methodology used to ensure the effective transfer of HSE knowledge and technology. The paper also offers an evaluation of the sessions and presents the plans developed by participant-teams for follow up on their return to Indonesia.« less
Location and age of foraminifer samples collected by Chevron Petroleum geologists in California
Brabb, Earl E.; Parker, John M.
2003-01-01
Most of the geologic maps published for parts of central California in the past century have been made without the benefit of ages from microfossils. The ages of Jurassic, Cretaceous and Tertiary rocks in the mostly poorly exposed and structurally complex sedimentary rocks represented in the Coast Ranges are critical in determining stratigraphic succession or lack of it, and in determining whether the juxtaposition of similar appearing but different age formations means that a fault is present. Since the 1940's, at least, oil company geologists have used microfossils to assist them in geologic mapping and in determining the environments of deposition of the sedimentary rocks containing them. This information had been so confidential that even the names of species were coded by some paleontologists to prevent disclosure. In the past 20 years, however, the attitude of petroleum companies about this information has changed, and many of the formerly confidential materials and reports are now available. We report here on an estimated 50,000 Chevron foraminifer samples from surface localities in more than 600 U.S. Geological Survey 7.5' quadrangles in California. Ages are provided for more than 27,000 of these samples which have been donated by Chevron, along with locality maps, paleontology reports, and other data, to the California Academy of Sciences. To our knowledge, this collection is the largest ever released to the public by a petroleum company for the West Coast. The information from the slides can be used to update geologic maps prepared without the benefit of microfossils, to study foraminifers of Jurassic, Cretaceous and Tertiary age collected from a variety of geologic environments, to analyze the depth and temperature of ocean water covering parts of California during these periods, and for solving nomenclature and other scientific problems.
Considerations in Forest Growth Estimation Between Two Measurements of Mapped Forest Inventory Plots
Michael T. Thompson
2006-01-01
Several aspects of the enhanced Forest Inventory and Analysis (FIA) program?s national plot design complicate change estimation. The design incorporates up to three separate plot sizes (microplot, subplot, and macroplot) to sample trees of different sizes. Because multiple plot sizes are involved, change estimators designed for polyareal plot sampling, such as those...
Snowmelt Runoff From Planted Conifers in Southwestern Wisconsin
Richard S. Sartz; David N. Tolsted
1976-01-01
Snowmelt overland flow was measured for one season from 10-year-old plantations of red pine, Norway spruce, European larch, and from old field control plots, on both north and south slopes. Pine and spruce plots produced more runoff than larch and old field plots; and south slope plots produced more runoff than north slope plots.
Procedures for establishing and maintaining permanent plots for silvicultural and yield research.
Robert O. Curtis
1983-01-01
This paper reviews procedures for establishing and maintaining permanent plots for silvicultural and yield research; discusses purposes, sampling, and plot design; points out common errors; and makes recommendations for research plot designs and procedures for measuring and recording data.
ERIC Educational Resources Information Center
Wills, Herbert III
1989-01-01
Describes ways to make magic squares of 4 by 4 matrices. Presents two handouts: (1) Sets of 4 Numbers from 1 to 16 Whose Sum is 34; and (2) The Durer Square. Shows patterns which appeared in the magic squares, such as squares, chevrons, rhomboids, and trapezoids. (YP)
From the Research Laboratory to the Operating Company: How Information Travels.
ERIC Educational Resources Information Center
Coppin, Ann S.; Palmer, Linda L.
1980-01-01
Reviews transmission processes of Chevron Oil Field Research Company (COFRC) research results from laboratories to end-user operating companies worldwide. Information dissemination methods described included informal communication, intercompany meetings, visits by COFRC personnel to operating company offices, distribution of written reports,…
Laser beam generating apparatus
Warner, Bruce E.; Duncan, David B.
1993-01-01
Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect).
Laser beam generating apparatus
Warner, Bruce E.; Duncan, David B.
1994-01-01
Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect).
Sulfur-doped Graphene Nanoribbons with a Sequence of Distinct Band Gaps
NASA Astrophysics Data System (ADS)
Du, Shi-Xuan; Zhang, Yan-Fang; Zhang, Yi; Berger, Reinhard; Feng, Xinliang; Mullen, Klaus; Lin, Xiao; Zhang, Yu-Yang; Pantelides, Sokrates T.; Gao, Hong-Jun
Unlike free-standing graphene, graphene nanoribbons (GNRs) can possess semiconducting band gap. However, achieving such control has been a major challenge in the fabrication of GNRs. Chevron-type GNRs were recently achieved by surface-assisted polymerization of pristine or N-substituted oligophenylene monomers. By mixing two different monomers, GNR heterojunctions can in principle be fabricated. Here we report fabrication and characterization of chevron-type GNRs by using sulfur-substituted oligophenylene monomers to achieve GNRs and related heterostructures for the first time. Importantly, our first-principles calculations show that the band gaps of GNRs can be tailored by different S configurations in cyclodehydrogenated isomers through debromination and intramolecular cyclodehydrogenation. This feature should open up new avenues to create multiple GNR heterojunctions by engineering the sulfur configurations. These predictions have been confirmed by Scanning Tunneling Microscopy (STM) and Scanning Tunneling Spectroscopy (STS). The unusual sequence of intraribbon heterojunctions may be useful for nanoscale optoelectronic applications based on quantum dots
NASA Astrophysics Data System (ADS)
Lestari, W. D.; Jamari, J.; Bayuseno, A. P.
2017-04-01
The texture shapes play a key role in the tribological performance of the surface material. This paper presents a study on the use of the 3D finite element method for surface stress analysis on the different texture shape under load and dry sliding contact. The five texture-shaped model was investigated in this work, namely square, circle, ellipse, triangle, and chevron. The result shown that the square shape has the highest value of von Mises resultant stress under static load. In contrast, the dry sliding contact on the triangle shape provided the highest von Mises stress distribution. The lowest value of von Mises stress can be found in the texture pattern of circle, square, and chevron under influence of load for 17 N, 30 N, and 50 N, respectively. Those texture patterns applied to surface of Ultra High Molecular Weight Polyethylene (UHMWPE) may have a strong effect on the reduction of wear rate and enhance tribological performance.
Design and Simulation of an Electrothermal Actuator Based Rotational Drive
NASA Astrophysics Data System (ADS)
Beeson, Sterling; Dallas, Tim
2008-10-01
As a participant in the Micro and Nano Device Engineering (MANDE) Research Experience for Undergraduates program at Texas Tech University, I learned how MEMS devices operate and the limits of their operation. Using specialized AutoCAD-based design software and the ANSYS simulation program, I learned the MEMS fabrication process used at Sandia National Labs, the design limitations of this process, the abilities and drawbacks of micro devices, and finally, I redesigned a MEMS device called the Chevron Torsional Ratcheting Actuator (CTRA). Motion is achieved through electrothermal actuation. The chevron (bent-beam) actuators cause a ratcheting motion on top of a hub-less gear so that as voltage is applied the CTRA spins. The voltage applied needs to be pulsed and the frequency of the pulses determine the angular frequency of the device. The main objective was to design electromechanical structures capable of transforming the electrical signals into mechanical motion without overheating. The design was optimized using finite element analysis in ANSYS allowing multi-physics simulations of our model system.
NASA Astrophysics Data System (ADS)
Yeh, Wenchang
2017-08-01
Micro chevron laser beam annealing (μCLBA) of Si film and Ge film were introduced. Single crystal stripe with a dimension of several tens to hundreds μm in length and 3-8μm in width was formed in Si film or Ge film by scanning μCLBA over the film. Main boundaries in the c-Si stripe were Σ3 CSL twin boundary. Scanning speed of micro linear laser beam annealing (μLLBA) was varied from 0.05 m/s to 8m/s to investigate its influence to crystallinity. Even at 8m/s lateral growth taken place, however, crystal quality was better for slower lateral growth. Crystallization area per energy (APE) of μLLBA was evaluated and compared with other methods. It was found APE of μLLBA was larger than other method, especially for a display with low fill factor of TFT, APE can be several orders of magnitude larger.
High dynamic range bio-molecular ion microscopy with the Timepix detector.
Jungmann, Julia H; MacAleese, Luke; Visser, Jan; Vrakking, Marc J J; Heeren, Ron M A
2011-10-15
Highly parallel, active pixel detectors enable novel detection capabilities for large biomolecules in time-of-flight (TOF) based mass spectrometry imaging (MSI). In this work, a 512 × 512 pixel, bare Timepix assembly combined with chevron microchannel plates (MCP) captures time-resolved images of several m/z species in a single measurement. Mass-resolved ion images from Timepix measurements of peptide and protein standards demonstrate the capability to return both mass-spectral and localization information of biologically relevant analytes from matrix-assisted laser desorption ionization (MALDI) on a commercial ion microscope. The use of a MCP-Timepix assembly delivers an increased dynamic range of several orders of magnitude. The Timepix returns defined mass spectra already at subsaturation MCP gains, which prolongs the MCP lifetime and allows the gain to be optimized for image quality. The Timepix peak resolution is only limited by the resolution of the in-pixel measurement clock. Oligomers of the protein ubiquitin were measured up to 78 kDa. © 2011 American Chemical Society
Where are the Black Walnut Trees in Michigan? 1995
J. Michael Vasievich; Neal P. Kingsley
1995-01-01
The latest Michigan forest inventory was completed in 1993 by the North Central Forest Experiment Station and the Michigan DNR, Forest Management Division. In total, 18,484 sample points were examined on aerial photographs to identify ground sample plots. Of these, 10,849 forest plots were visited and measured on the ground by field crews. These plot measurements...
Grassland degradation caused by tourism activities in Hulunbuir, Inner Mongolia, China
NASA Astrophysics Data System (ADS)
Le, C.; Ikazaki, K.; Siriguleng; Kadono, A.; Kosaki, T.
2014-02-01
The recent increase in the number of tourists has raised serious concerns about grassland degradation by tourism activities in Inner Mongolia. Thus, we evaluated the effects of tourism activities on the vegetation and soil in Hulunbuir grassland. We identified all the plant species, measured the number and height of plant and plant coverage rate, and calculated species diversity, estimated above-ground biomass in use plot and non-use plot. We also measured soil hardness, and collected soil samples for physical and chemical analysis in both plots. The obtained results were as follows: a) the height of the dominant plants, plant coverage rate, species diversity, and above-ground biomass were significantly lower in use plot than in non-use plot, b) Carex duriuscula C.A.Mey., indicator plant for soil degradation, was dominant in use plot, c) soil hardness was significantly higher in use plot than in non-use plot, and spatial dependence of soil hardness was only found in the use plot, d) CEC, TC, TN and pH in the topsoil were significantly lower in use plot than non-use plot. On the basis of the results, we concluded that the tourism activities can be another major cause of the grassland degradation in Inner Mongolia.
A Program of Leadership Development.
ERIC Educational Resources Information Center
Charitat, Mac
1988-01-01
The Chevron/Mayoral Fellowship program in New Orleans is described. The program provides private funding to support 30 selected high school students each summer in internships in city government agencies. Evaluation after three years has been positive and demonstrate the potential of a governmental/public/private educational program. (DB)
Laser beam generating apparatus
Warner, B.E.; Duncan, D.B.
1993-12-28
Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 11 figures.
Effectiveness of surgery for adults with hallux valgus deformity: a systematic review.
Klugarova, Jitka; Hood, Victoria; Bath-Hextall, Fiona; Klugar, Miloslav; Mareckova, Jana; Kelnarova, Zuzana
2017-06-01
Hallux valgus (HV) is a common foot deformity. In severe stages of this condition, surgery is often necessary. Currently, there is no systematic review comparing the effectiveness of surgery over conservative treatment. The objective of this review was to establish the effectiveness of surgery compared to conservatory management for adults with HV. The current review included adults (18 years or over) with HV deformity, excluding adults with neurological problems causing foot deformities, for example, cerebral palsy, neuropathy, stroke and multiple sclerosis. The review included any type of HV surgery compared to no surgery, conservative treatment or different types of HV surgeries. The primary outcome was gait measurement, and secondary outcomes included quality of life, patient satisfaction, pain assessed using any validated assessment tool and adverse events. The review included randomized controlled trials. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in 16 databases without language and date limitations. Papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments developed by the Joanna Briggs Institute (JBI). Data were extracted from papers included in the review using the standardized data extraction tool developed by the JBI. Quantitative data were, where possible, pooled in statistical meta-analysis using RevMan5 (Copenhagen: The Nordic Cochrane Centre, Cochrane). Effect sizes expressed as risk ratio (for categorical data) and mean differences (MD) or standardized MD (for continuous data) and their 95% confidence intervals were calculated for analysis. Where statistical pooling was not possible, the findings have been presented in narrative form. Searching identified 2412 citations. After removal of duplicates, paper retrieval and critical appraisal, 25 studies were included in the review. The included trials were of medium-to-poor quality.Twenty-four trials compared the effectiveness of different types of surgeries. Meta-analysis revealed no difference in level of pain between distal chevron-type osteotomy and other surgical procedures (standard mean difference [SMD] 0.02, 95% confidence interval [CI] -0.24 to 0.28). One single trial reported that distal chevron osteotomy is more effective than Lindgren osteotomy in terms of walking speed (MD -0.24, 95% CI -0.43 to -0.05).One medium quality trial assessed the effectiveness of HV surgery compared to conservative or no treatment. This trial showed that surgery, specifically distal chevron osteotomy of the first metatarsal, is a more effective procedure for pain compared to conservative treatment (MD -15.00, 95% CI -22.79 to -7.21) and also no treatment in the first year (MD -18.00, 95% CI -25.62 to -10.38). The current systematic review showed that differences between various types of surgical procedures, specifically osteotomies of the first metatarsal on clinical outcomes, are minimal. There is evidence from one study, that surgery, specifically distal chevron osteotomy of the first metatarsal is a more effective procedure than conservative or no treatment in reducing pain in the first year following surgery. However, this systematic review has identified that there is a lack of high-quality studies comparing similar types of HV treatments that assess the same outcomes.
Strategies for minimizing sample size for use in airborne LiDAR-based forest inventory
Junttila, Virpi; Finley, Andrew O.; Bradford, John B.; Kauranne, Tuomo
2013-01-01
Recently airborne Light Detection And Ranging (LiDAR) has emerged as a highly accurate remote sensing modality to be used in operational scale forest inventories. Inventories conducted with the help of LiDAR are most often model-based, i.e. they use variables derived from LiDAR point clouds as the predictive variables that are to be calibrated using field plots. The measurement of the necessary field plots is a time-consuming and statistically sensitive process. Because of this, current practice often presumes hundreds of plots to be collected. But since these plots are only used to calibrate regression models, it should be possible to minimize the number of plots needed by carefully selecting the plots to be measured. In the current study, we compare several systematic and random methods for calibration plot selection, with the specific aim that they be used in LiDAR based regression models for forest parameters, especially above-ground biomass. The primary criteria compared are based on both spatial representativity as well as on their coverage of the variability of the forest features measured. In the former case, it is important also to take into account spatial auto-correlation between the plots. The results indicate that choosing the plots in a way that ensures ample coverage of both spatial and feature space variability improves the performance of the corresponding models, and that adequate coverage of the variability in the feature space is the most important condition that should be met by the set of plots collected.
Laser beam generating apparatus
Warner, B.E.; Duncan, D.B.
1994-02-15
Laser beam generating apparatus including a septum segment disposed longitudinally within the tubular structure of the apparatus is described. The septum provides for radiatively dissipating heat buildup within the tubular structure and for generating relatively uniform laser beam pulses so as to minimize or eliminate radial pulse delays (the chevron effect). 7 figures.
Energy landscape of knotted protein folding
Sułkowska, Joanna I.; Noel, Jeffrey K.; Onuchic, Jose N.
2012-01-01
Recent experiments have conclusively shown that proteins are able to fold from an unknotted, denatured polypeptide to the knotted, native state without the aid of chaperones. These experiments are consistent with a growing body of theoretical work showing that a funneled, minimally frustrated energy landscape is sufficient to fold small proteins with complex topologies. Here, we present a theoretical investigation of the folding of a knotted protein, 2ouf, engineered in the laboratory by a domain fusion that mimics an evolutionary pathway for knotted proteins. Unlike a previously studied knotted protein of similar length, we see reversible folding/knotting and a surprising lack of deep topological traps with a coarse-grained structure-based model. Our main interest is to investigate how evolution might further select the geometry and stiffness of the threading region of the newly fused protein. We compare the folding of the wild-type protein to several mutants. Similarly to the wild-type protein, all mutants show robust and reversible folding, and knotting coincides with the transition state ensemble. As observed experimentally, our simulations show that the knotted protein folds about ten times slower than an unknotted construct with an identical contact map. Simulated folding kinetics reflect the experimentally observed rollover in the folding limbs of chevron plots. Successful folding of the knotted protein is restricted to a narrow range of temperature as compared to the unknotted protein and fits of the kinetic folding data below folding temperature suggest slow, nondiffusive dynamics for the knotted protein. PMID:22891304
Laser notching ceramics for reliable fracture toughness testing
Barth, Holly D.; Elmer, John W.; Freeman, Dennis C.; ...
2015-09-19
A new method for notching ceramics was developed using a picosecond laser for fracture toughness testing of alumina samples. The test geometry incorporated a single-edge-V-notch that was notched using picosecond laser micromachining. This method has been used in the past for cutting ceramics, and is known to remove material with little to no thermal effect on the surrounding material matrix. This study showed that laser-assisted-machining for fracture toughness testing of ceramics was reliable, quick, and cost effective. In order to assess the laser notched single-edge-V-notch beam method, fracture toughness results were compared to results from other more traditional methods, specificallymore » surface-crack in flexure and the chevron notch bend tests. Lastly, the results showed that picosecond laser notching produced precise notches in post-failure measurements, and that the measured fracture toughness results showed improved consistency compared to traditional fracture toughness methods.« less
Sidney Blatt's Object Relations Inventory: Contributions and Future Directions.
Huprich, Steven K; Auerbach, John S; Porcerelli, John H; Bupp, Lindsey L
2016-01-01
In this article, we provide a historical overview of the Object Relations Inventory (ORI) and related methods for the assessment of object relations constructed by Sidney Blatt and colleagues (e.g., Blatt, Bers, & Schaffer, 1992 ; Blatt, Wein, Chevron, & Quinlan, 1979 ; Diamond, Kaslow, Coonerty, & Blatt, 1990 ). We clarify terminology that has been used inconsistently in the literature, especially by way of differentiating the methods used to collect descriptions of significant figures, such as the ORI and its predecessor, the Parental Description (PD) task, and the rating scales that Blatt and colleagues constructed to rate those descriptions. We provide a tabular summary of empirical studies of the measure and offer a critical review of those aspects of the instrument that require further empirical investigation and methodological rigor.
Fracture toughness of ultrashort pulse-bonded fused silica
NASA Astrophysics Data System (ADS)
Richter, S.; Naumann, F.; Zimmermann, F.; Tünnermann, A.; Nolte, S.
2016-02-01
We determined the bond interface strength of ultrashort pulse laser-welded fused silica for different processing parameters. To this end, we used a high repetition rate ultrashort pulse laser system to inscribe parallel welding lines with a specific V-shaped design into optically contacted fused silica samples. Afterward, we applied a micro-chevron test to measure the fracture toughness and surface energy of the laser-inscribed welding seams. We analyzed the influence of different processing parameters such as laser repetition rate and line separation on the fracture toughness and fracture surface energy. Welding the entire surface a fracture toughness of 0.71 {MPa} {m}^{1/2}, about 90 % of the pristine bulk material ({≈ } 0.8 {MPa} {m}^{1/2}), is obtained.
Flow-Field Surveys for Rectangular Nozzles. Supplement
NASA Technical Reports Server (NTRS)
Zaman, K. B. M. Q.
2012-01-01
Flow field survey results for three rectangular nozzles are presented for a low subsonic condition obtained primarily by hot-wire anemometry. The three nozzles have aspect ratios of 2:1, 4:1 and 8:1. A fourth case included has 2:1 aspect ratio with chevrons added to the long edges. Data on mean velocity, turbulent normal and shear stresses as well as streamwise vorticity are presented covering a streamwise distance up to sixteen equivalent diameters from the nozzle exit. These detailed flow properties, including initial boundary layer characteristics, are usually difficult to measure in high speed flows and the primary objective of the study is to aid ongoing and future computational and noise modeling efforts. This supplement contains data files, charts and source code.
Computer systems and methods for visualizing data
Stolte, Chris; Hanrahan, Patrick
2010-07-13
A method for forming a visual plot using a hierarchical structure of a dataset. The dataset comprises a measure and a dimension. The dimension consists of a plurality of levels. The plurality of levels form a dimension hierarchy. The visual plot is constructed based on a specification. A first level from the plurality of levels is represented by a first component of the visual plot. A second level from the plurality of levels is represented by a second component of the visual plot. The dataset is queried to retrieve data in accordance with the specification. The data includes all or a portion of the dimension and all or a portion of the measure. The visual plot is populated with the retrieved data in accordance with the specification.
Computer systems and methods for visualizing data
Stolte, Chris; Hanrahan, Patrick
2013-01-29
A method for forming a visual plot using a hierarchical structure of a dataset. The dataset comprises a measure and a dimension. The dimension consists of a plurality of levels. The plurality of levels form a dimension hierarchy. The visual plot is constructed based on a specification. A first level from the plurality of levels is represented by a first component of the visual plot. A second level from the plurality of levels is represented by a second component of the visual plot. The dataset is queried to retrieve data in accordance with the specification. The data includes all or a portion of the dimension and all or a portion of the measure. The visual plot is populated with the retrieved data in accordance with the specification.
Integrating P3 Data Into P2 Analyses: What is the Added Value
James R. Steinman
2001-01-01
The Forest Inventory and Analysis and Forest Health Monitoring Programs of the USDA Forest Service are integrating field procedures for measuring their networks of plots throughout the United States. These plots are now referred to as Phase 2 (P2) and Phase 3 (P3) plots, respectively, and 1 out of every 16 P2 plots will also be a P3 plot. Mensurational methods will be...
Shi, Zhonglin; Wen, Anbang; Zhang, Xinbao; Yan, Dongchun
2011-10-01
The potential for using (7)Be measurements to document soil redistribution associated with a heavy rainfall was estimated using (7)Be method on a bare purple soil plot in the Three Gorges Reservoir region of China. The results were compared with direct measurement from traditional approaches of erosion pins and runoff plots. The study shows that estimation of soil losses from (7)Be are comparable with the monitoring results provided by erosion pins and runoff plots, and are also in agreement with the existing knowledge provided by 137Cs measurements. The results obtained from this study demonstrated the potential for using (7)Be technique to quantify short-term erosion rates in these areas. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zhu, T X
2016-03-01
In this study, multi-year stormflow data collected at both catchment and plot scales on an event basis were used to evaluate the efficiency of conservation. At the catchment scale, soil loss from YDG, an agricultural catchment with no conservation measures, was compared with that from CZG, an agricultural catchment with an implementation of a range of conservation measures. With an increase of storm recurrence intervals in the order of <1, 1-2, 2-5, 5-10, 10-20, and >20 years, the mean event sediment yield was 639, 1721, 5779, 15191, 19627, and 47924 t/km(2) in YDG, and was 244, 767, 3077, 4679, 8388, and 15868 t/km(2) in CZG, which represented a reduction effectiveness of 61.8, 55.4, 46.7, 69.2, 57.2, and 66.8 %, respectively. Storm events with recurrence intervals greater than 2 years contributed about two-thirds of the total runoff and sediment in both YDG and CZG catchments. At the plot scale, soil loss from one cultivated slopeland was compared with that from five conservation plots. The mean event soil loss was 1622 t/km(2) on the cultivated slopeland, in comparison to 27.7 t/km(2) on the woodland plot, 213 t/km(2) on the grassland plot, 467 t/km(2) on the alfalfa plot, 236 t/km(2) on the terraceland plot, and 642 t/km(2) on the earthbank plot. Soil loss per unit area from all the plots was significantly less than that from the catchments for storms of all categories of recurrence intervals.
Comparison of scalar measures used in magnetic resonance diffusion tensor imaging.
Bahn, M M
1999-07-01
The tensors derived from diffusion tensor imaging describe complex diffusion in tissues. However, it is difficult to compare tensors directly or to produce images that contain all of the information of the tensor. Therefore, it is convenient to produce scalar measures that extract desired aspects of the tensor. These measures map the three-dimensional eigenvalues of the diffusion tensor into scalar values. The measures impose an order on eigenvalue space. Many invariant scalar measures have been introduced in the literature. In the present manuscript, a general approach for producing invariant scalar measures is introduced. Because it is often difficult to determine in clinical practice which of the many measures is best to apply to a given situation, two formalisms are introduced for the presentation, definition, and comparison of measures applied to eigenvalues: (1) normalized eigenvalue space, and (2) parametric eigenvalue transformation plots. All of the anisotropy information contained in the three eigenvalues can be retained and displayed in a two-dimensional plot, the normalized eigenvalue plot. An example is given of how to determine the best measure to use for a given situation by superimposing isometric contour lines from various anisotropy measures on plots of actual measured eigenvalue data points. Parametric eigenvalue transformation plots allow comparison of how different measures impose order on normalized eigenvalue space to determine whether the measures are equivalent and how the measures differ. These formalisms facilitate the comparison of scalar invariant measures for diffusion tensor imaging. Normalized eigenvalue space allows presentation of eigenvalue anisotropy information. Copyright 1999 Academic Press.
Forest Health Monitoring in Maryland 1996-1999
Northeastern Research Station
2003-01-01
The National Forest Health Monitoring (FHM) program monitors the long-term status, changes and trends in the health of forest ecosystems and is conducted in cooperation with individual states. In Maryland, 40 FHM plots were established in 1991. Beginning in 1998, 95 plots were added. Each plot is a series of four fixed-area circular plots. Most tree measurements are...
Measurements of smoke from chipped and unchipped plots
Gary L. Achtemeier; Jeff Glitzenstein; Luke P. Naeher
2006-01-01
Smoke data were collected from two instrumented plots located on the Francis Marion National Forest in South Carolina during prescribed burns on Feb. 12, 2003. One of the plots had been subjected to mechanical chipping. Particulate matter (PM2.5) data analyzed by gravimetric methods were collected at nine locations on the downwind sides of each plot. In addition,...
Jeyaseelan, L; Chandrashekar, S; Mulligan, A; Bosman, H A; Watson, A J S
2016-09-01
The mainstay of surgical correction of hallux valgus is first metatarsal osteotomy, either proximally or distally. We present a technique of combining a distal chevron osteotomy with a proximal opening wedge osteotomy, for the correction of moderate to severe hallux valgus. We reviewed 45 patients (49 feet) who had undergone double osteotomy. Outcome was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) and the Short Form (SF) -36 Health Survey scores. Radiological measurements were undertaken to assess the correction. The mean age of the patients was 60.8 years (44.2 to 75.3). The mean follow-up was 35.4 months (24 to 51). The mean AOFAS score improved from 54.7 to 92.3 (p < 0.001) and the mean SF-36 score from 59 to 86 (p < 0.001). The mean hallux valgus and intermetatarsal angles were improved from 41.6(o) to 12.8(o) (p < 0.001) and from 22.1(o) to 7.1(o), respectively (p < 0.001). The mean distal metatarsal articular angle improved from 23(o) to 9.7(o). The mean sesamoid position, as described by Hardy and Clapham, improved from 6.8 to 3.5. The mean length of the first metatarsal was unchanged. The overall rate of complications was 4.1% (two patients). These results suggest that a double osteotomy of the first metatarsal is a reliable, safe technique which, when compared with other metatarsal osteotomies, provides strong angular correction and excellent outcomes with a low rate of complications. Cite this article: Bone Joint J 2016;98-B:1202-7. ©2016 The British Editorial Society of Bone & Joint Surgery.
An active locking mechanism for assembling 3D micro structures
NASA Astrophysics Data System (ADS)
Zhang, Ping; Mayyas, Mohammad; Lee, Woo Ho; Popa, Dan; Shiakolas, Panos; Stephanou, Harry; Chiao, J. C.
2007-01-01
Microassembly is an enabling technology to build 3D microsystems consisting of microparts made of different materials and processes. Multiple microparts can be connected together to construct complicated in-plane and out-of-plane microsystems by using compliant mechanical structures such as micro hinges and snap fasteners. This paper presents design, fabrication, and assembly of an active locking mechanism that provides mechanical and electrical interconnections between mating microparts. The active locking mechanism is composed of thermally actuated Chevron beams and sockets. Assembly by means of an active locking mechanism offers more flexibility in designing microgrippers as it reduces or minimizes mating force, which is one of the main reasons causing fractures in a microgripper during microassembly operation. Microgrippers, microparts, and active locking mechanisms were fabricated on a silicon substrate using the deep reactive ion etching (DRIE) processes with 100-um thick silicon on insulator (SOI) wafers. A precision robotic assembly platform with a dual microscope vision system was used to automate the manipulation and assembly processes of microparts. The assembly sequence includes (1) tether breaking and picking up of a micropart by using an electrothermally actuated microgripper, (2) opening of a socket area for zero-force insertion, (3) a series of translation and rotation of a mating micropart to align it onto the socket, (4) insertion of a micropart into the socket, and (5) deactivation and releasing of locking fingers. As a result, the micropart was held vertically to the substrate and locked by the compliance of Chevron beams. Microparts were successfully assembled using the active locking mechanism and the measured normal angle was 89.2°. This active locking mechanism provides mechanical and electrical interconnections, and it can potentially be used to implement a reconfigurable microrobot that requires complex assembly of multiple links and joints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, P.J.,; Phillips, J.R.; Wullschelger, S.D.
This data set reports tree growth measurements of mature Picea mariana and Larix laricina located in the S1-Bog permanent plots and the SPRUCE experimental study plots, Annual data collections were initiated in February of 2011and have been continued on an annual basis during mid-winter observation periods at the end of February or early March. Data collections are anticipated to continue through February of 2025 and this data set will be appended annually. Initial observations in 2011 included measurements of circumference at 1.3 m (diameter at breast height assessments; DBH) above the nominal bog hollow surface, tree heights and crown diameters.more » Subsequent annual measurements have focused on the measures of circumference at DBH. Circumference measurements to the nearest 0.1 cm are converted to DBH in cm and basal area at DBH in (cm2). Tree height and crown diameter are measured to the nearest 0.1 m.« less
Vegetative Erosion Control Studies Tennessee-Tombigbee Waterway.
1981-01-01
stabilization and temporary cover . Rye : Rye is a cool season annual grass. Its use for soil stabili- zation is for rapid soil stability and temporary cover ...except for those plots seeded with rye , Rye seeded plots showed greater % cover on both slope exposures compared to all other plots. An observa- tion...trend is opposite to that measured in June and August 1977. The % cover of rye plots decreased and showed lowest density compared to all other plots
SPRUCE Bog Surface Elevation Assessments with SET Instrument Beginning in 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, Paul J; Phillips, Jana R; Brice, Deanne J
This data set reports plot-specific bog surface elevation measurements collected with the SPRUCE Elevation Transect (SET) instrument. Measurements are reported as absolute elevation in meters above mean sea level for two locations in each of the SPRUCE experimental treatment plots and additional ambient boardwalk plots -- 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16, 17, 19, 20 and 21. This data set reports measurements collected from June 2013 through August 2017, but it will be appended annually as new data are collected.
Saito, Takaya; Rehmsmeier, Marc
2015-01-01
Binary classifiers are routinely evaluated with performance measures such as sensitivity and specificity, and performance is frequently illustrated with Receiver Operating Characteristics (ROC) plots. Alternative measures such as positive predictive value (PPV) and the associated Precision/Recall (PRC) plots are used less frequently. Many bioinformatics studies develop and evaluate classifiers that are to be applied to strongly imbalanced datasets in which the number of negatives outweighs the number of positives significantly. While ROC plots are visually appealing and provide an overview of a classifier's performance across a wide range of specificities, one can ask whether ROC plots could be misleading when applied in imbalanced classification scenarios. We show here that the visual interpretability of ROC plots in the context of imbalanced datasets can be deceptive with respect to conclusions about the reliability of classification performance, owing to an intuitive but wrong interpretation of specificity. PRC plots, on the other hand, can provide the viewer with an accurate prediction of future classification performance due to the fact that they evaluate the fraction of true positives among positive predictions. Our findings have potential implications for the interpretation of a large number of studies that use ROC plots on imbalanced datasets.
DOT National Transportation Integrated Search
1990-12-01
This report covers the construction of open-graded asphalt concrete test sections using one conventional and three different polymerized binders. The binders were: 1) Chevron's conventional AC-20 as a control, 2) Elf Aquitane's Styrelf with SB polyme...
NASA Technical Reports Server (NTRS)
Oeffinger, T. R.; Tocci, L. R.
1977-01-01
Instrument design provides replicate function between device storage area and guardrail detector in order that nondestructive read-out of memory can be achieved. Use of guardrail detectors in magnetic domain (bubble) circuits is proposed method of increasing detector signal output by increasing detector size without dedicating an excessive amount of device chip area to detector portion.
USDA-ARS?s Scientific Manuscript database
The entomopathogenic anamorphic genus Evlachovaea was described to differ from other fungi in forming its conidia obliquely to the axis of the conidiogenous cell and with successive conidia having alternate orientations with a zipper- or chevron-like arrangement resulting in flat, ribbon-like chains...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-13
...-way (ROW) authorization to construct and operate a 45-megawatt (MW) solar photovoltaic project which... Solar Project, California and the Approved Plan Amendment to the California Desert Conservation Area...) Lucerne Valley Solar Project located in San Bernardino County, California. The Secretary of the Interior...
2007-01-01
Coal Power Plant , Dickerson, MD Consol Corporation, Morgantown and Wanna, WV Chevron Corporation, San Ramon, CA Valero Refinery , Benicia, CA Pacific...important petrochemical industry Cons: Reliance on imports from volatile regions Greenhouse gas emissions Policy Recommendations: Limit number...nuclear power, and reduce hazardous emissions through the development of cleaner burning technologies and use of alternative fuels. Specifically, the
Publications - GMC 123 | Alaska Division of Geological & Geophysical
DGGS GMC 123 Publication Details Title: Total organic carbon and rock-eval pyrolysis data of select organic carbon and rock-eval pyrolysis data of select cuttings from the Chevron USA Akulik #1 well: Alaska Pyrolysis; Rock-Eval Pyrolysis Top of Page Department of Natural Resources, Division of Geological &
Defense Industry Consolidation and Weapon Systems Cost Growth
2008-06-01
consolidation in the industry. Year Buyer Target Price ($Billions) 1988 Kohlberg Kravis RJR Nabisco 25.1 1984 Chevron Gulf Oil 13.3 1988 Philip Morris Kraft...Steel Marathon Oil 6.6 1988 Campeau Federated Stores 6.5 1986 Kohlberg Kravis Beatrice 6.2 Table 7. Ten Largest Acquisitions 1981 – 1989 (Aftrer54
Proximal metatarsal osteotomies: a comparative geometric analysis conducted on sawbone models.
Nyska, Meir; Trnka, Hans-Jörg; Parks, Brent G; Myerson, Mark S
2002-10-01
We evaluated the change in position of the first metatarsal head using a three-dimensional digitizer on sawbone models. Crescentic, closing wedge, oblique shaft (Ludloff 8 degrees and 16 degrees), reverse oblique shaft (Mau 8 degrees and 16 degrees), rotational "Z" (Scarf), and proximal chevron osteotomies were performed and secured using 3-mm screws. The 16 degrees Ludloff provided the most lateral shift (9.5 mm) and angular correction (14.5 degrees) but also produced the most elevation (1.4 mm) and shortening (2.9 mm). The 8 degrees Ludloff provided lateral and angular corrections similar to those of the crescentic and closing wedge osteotomies with less elevation and shortening. Because the displacement osteotomies (Scarf, proximal chevron) provided less angular correction, the same lateral displacement, and less shortening than the basilar angular osteotomies, based upon this model they can be more reliably used for a patient with a mild to moderate deformity, a short first metatarsal, or an intermediate deformity with a large distal metatarsal articular angle. These results can serve as recommendations for selecting the optimal osteotomy with which to correct a deformation.
Folding and faulting of an elastic continuum
NASA Astrophysics Data System (ADS)
Bigoni, Davide; Gourgiotis, Panos A.
2016-03-01
Folding is a process in which bending is localized at sharp edges separated by almost undeformed elements. This process is rarely encountered in Nature, although some exceptions can be found in unusual layered rock formations (called `chevrons') and seashell patterns (for instance Lopha cristagalli). In mechanics, the bending of a three-dimensional elastic solid is common (for example, in bulk wave propagation), but folding is usually not achieved. In this article, the route leading to folding is shown for an elastic solid obeying the couple-stress theory with an extreme anisotropy. This result is obtained with a perturbation technique, which involves the derivation of new two-dimensional Green's functions for applied concentrated force and moment. While the former perturbation reveals folding, the latter shows that a material in an extreme anisotropic state is also prone to a faulting instability, in which a displacement step of finite size emerges. Another failure mechanism, namely the formation of dilation/compaction bands, is also highlighted. Finally, a geophysical application to the mechanics of chevron formation shows how the proposed approach may explain the formation of natural structures.
Characterization of a highly efficient chevron-shaped anti-contamination device
NASA Astrophysics Data System (ADS)
Fiore, M.; Vermeersch, O.; Forte, M.; Casalis, G.; François, C.
2016-04-01
This paper is devoted to the characterization of an optimized chevron-shaped anti-contamination device (ACD). This device can prevent efficiently the propagation of turbulence from the fuselage along the attachment line (hypothetical streamline that spreads the flow going to suction side and the one going to pressure side) of swept wings and enables the development of a new laminar boundary layer downstream. More specifically, the aim is to prevent boundary-layer transition along the attachment line by a contamination process. This process is characterized by the typical Reynolds number overline{R} and the associated Poll's criterion. Thus, ACD efficiency will be expressed in terms of overline{R} values. Some experiments performed on a new numerically optimized ACD have shown its ability to prevent leading-edge contamination up to overline{R} values close to the natural transition process of the laminar boundary layer along the attachment line. The corresponding stability analysis of the laminar boundary layer is made using the Görtler-Hämmerlin stability approach. The study is completed with the different transition processes that can occur downstream the attachment line, around the airfoil, especially with crossflow analysis.
Drug and alcohol abuse: The pattern and magnitude of the problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ajayi, P.A.
In the last 12 months, many more cases of alcohol and drug (substance) abuse in the workplace were seen in the Escravos operations of Chevron Nigeria Limited than in previous years. This called the attention to the rising prevalence of drug and alcohol abuse in contradistinction to reports from similar organizations in other parts of the world. Chevron Nigeria has a written Drug and Alcohol Policy which has been dormant for some time because of the apparent rarity of the problem of substance abuse in the workplace. This Policy is being reviewed to broaden its scope and make it moremore » effective. A total of 30 employees were tested for drugs and alcohol .6 exceeded the legal limits of Blood Alcohol Concentration (BAC) and 5 tested positive for drugs. Tests were mainly post-accident, reasonable cause and random. The common substances abused were alcohol, cannabis, cocaine and morphine in that order. The findings are compared with those of similar organizations in UK and USA. Efforts to control substance abuse in the workplace are being put into place.« less
NASA Technical Reports Server (NTRS)
Waterman, A. W.; Huxford, R. L.; Nelson, W. G.
1976-01-01
Molded high temperature plastic first and second stage rod seal elements were evaluated in seal assemblies to determine performance characteristics. These characteristics were compared with the performance of machined seal elements. The 6.35 cm second stage Chevron seal assembly was tested using molded Chevrons fabricated from five molding materials. Impulse screening tests conducted over a range of 311 K to 478 K revealed thermal setting deficiencies in the aromatic polyimide molding materials. Seal elements fabricated from aromatic copolyester materials structurally failed during impulse cycle calibration. Endurance testing of 3.85 million cycles at 450 K using MIL-H-83283 fluid showed poorer seal performance with the unfilled aromatic polyimide material than had been attained with seals machined from Vespel SP-21 material. The 6.35 cm first stage step-cut compression loaded seal ring fabricated from copolyester injection molding material failed structurally during impulse cycle calibration. Molding of complex shape rod seals was shown to be a potentially controllable technique, but additional molding material property testing is recommended.
Solis, Kyle J.; Martin, James E.
2017-07-06
In recent years a rich variety of emergent phenomena have been observed when suspensions of magnetic particles are subjected to alternating magnetic fields. These particle assemblies often exhibit vigorous dynamics due to the injection of energy from the field. These include surface and interface phenomena, such as highly organized, segmented “snakes” that can be induced to swim by structural symmetry breaking, and “asters” and “anti-asters,” particle assemblies that can be manipulated to capture and transport cargo. In bulk suspensions of magnetic platelets subjected to multiaxial alternating fields, advection lattices and even vortex lattices have been created, and a variety ofmore » biomimetic dynamics – serpents, bees and amoebas – have been discovered in magnetic fluids suspended in an immiscible liquid. In this paper several new driven phases are presented, including flying chevrons, dense spinning clusters, filaments, and examples of phase coexistence in driven phases. These observations broaden the growing field of driven magnetic suspensions and present new challenges to those interested in simulating the dynamics of these complex systems.« less
Variable Selection Strategies for Small-area Estimation Using FIA Plots and Remotely Sensed Data
Andrew Lister; Rachel Riemann; James Westfall; Mike Hoppus
2005-01-01
The USDA Forest Service's Forest Inventory and Analysis (FIA) unit maintains a network of tens of thousands of georeferenced forest inventory plots distributed across the United States. Data collected on these plots include direct measurements of tree diameter and height and other variables. We present a technique by which FIA plot data and coregistered...
USDA-ARS?s Scientific Manuscript database
Research to measure soil erosion rates in the United States from natural rainfall runoff plots began in the early 1900’s. In Brazil, the first experimental study at the plot-scale was conducted in the 1940’s; however, the monitoring process and the creation of new experimental field plots have not c...
Mark J. Brown
2007-01-01
This bulletin highlights principal findings of an annual inventory of Florida's forests. Data summaries are based on measurements of 60 percent of the plots in the State. Additional data summaries and bulletins will be published as the remaining plots are measured.
[Comparative quality measurements part 3: funnel plots].
Kottner, Jan; Lahmann, Nils
2014-02-01
Comparative quality measurements between organisations or institutions are common. Quality measures need to be standardised and risk adjusted. Random error must also be taken adequately into account. Rankings without consideration of the precision lead to flawed interpretations and enhances "gaming". Application of confidence intervals is one possibility to take chance variation into account. Funnel plots are modified control charts based on Statistical Process Control (SPC) theory. The quality measures are plotted against their sample size. Warning and control limits that are 2 or 3 standard deviations from the center line are added. With increasing group size the precision increases and so the control limits are forming a funnel. Data points within the control limits are considered to show common cause variation; data points outside special cause variation without the focus of spurious rankings. Funnel plots offer data based information about how to evaluate institutional performance within quality management contexts.
Data documentation for the bare soil experiment at the University of Arkansas
NASA Technical Reports Server (NTRS)
Waite, W. P.; Scott, H. D. (Principal Investigator); Hancock, G. D.
1980-01-01
The reflectivities of several controlled moisture test plots were investigated. These test plots were of a similar soil texture which was clay loam and were prepared to give a desired initial soil moisture and density profile. Measurements were conducted on the plots as the soil water redistributed for both long term and diurnal cycles. These measurements included reflectivity, gravimetric and volumetric soil moisture, soil moisture potential, and soil temperature.
SPRUCE Hollow Elevation Data for Experimental Plots Beginning in 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffiths, N. A.; Sebestyen, S. D.
2017-01-01
This data set provides hollow elevation data for the 17 SPRUCE experimental plots in the S1 bog on the Marcell Experimental Forest. Hollows were selected for measurement by walking along each octagonal boardwalk segment in a plot and identifying where a hollow intersected the boardwalk. The vertical distance between the surface of the boardwalk (with a known elevation) and the surface of the hollow was measured and the absolute elevation (in meters amsl) of the hollow surface was calculated. The hollow elevation measurements were carried out in October 2015, May 2016, and October 2016. These measurements will be repeated annuallymore » or more frequently.« less
Properties of added variable plots in Cox's regression model.
Lindkvist, M
2000-03-01
The added variable plot is useful for examining the effect of a covariate in regression models. The plot provides information regarding the inclusion of a covariate, and is useful in identifying influential observations on the parameter estimates. Hall et al. (1996) proposed a plot for Cox's proportional hazards model derived by regarding the Cox model as a generalized linear model. This paper proves and discusses properties of this plot. These properties make the plot a valuable tool in model evaluation. Quantities considered include parameter estimates, residuals, leverage, case influence measures and correspondence to previously proposed residuals and diagnostics.
NASA Astrophysics Data System (ADS)
Yan, Dan-Ping; Zhou, Mei-Fu; Song, Hong-Lin; Wang, Xin-Wen; Malpas, John
2003-01-01
In the Yangtze Block (South China), a well-developed Mesozoic thrust system extends through the Xuefeng and Wuling mountains in the southeast to the Sichuan basin in the northwest. The system comprises both thin- and thick-skinned thrust units separated by a boundary detachment fault, the Dayin fault. To the northwest, the thin-skinned belt is characterized by either chevron anticlines and box synclines to the northwest or chevron synclines to the southeast. The former structural style displays narrow exposures for the cores of anticlines and wider exposures for the cores of synclines. Thrust detachments occur along Silurian (Fs) and Lower Cambrian (Fc) strata and are dominantly associated with the anticlines. To the southeast, this style of deformation passes gradually into one characterized by chevron synclines with associated principal detachment faults along Silurian (Fs), Cambrian (Fc) and Lower Sinian (Fz) strata. There are, however, numerous secondary back thrusts. Therefore, the thin-skinned belt is like the Valley and Ridge Province of the North American Applachian Mountains. The thick-skinned belt structurally overlies the thin-skinned belt and is characterized by a number of klippen including the Xuefeng and Wuling nappes. It is thus comparable to the Blue Ridge Province of Appalachia. The structural pattern of this thrust system in South China can be explained by a model involving detachment faulting along various stratigraphic layers at different stages of its evolution. The system was developed through a northwest stepwise progression of deformation with the earliest delamination along Lower Sinian strata (Fz). Analyses of balanced geological cross-sections yield about 18.1-21% (total 88 km) shortening for the thin-skinned unit and at least this amount of shortening for the thick-skinned unit. The compressional deformation from southeast to northwest during Late Jurassic to Cretaceous time occurred after the westward progressive collision of the Yangtze Block with the North China Block and suggests that the orogenic event was intracontinental in nature.
Park, Chul Hyun; Lee, Woo-Chun
We compared the results of proximal chevron osteotomy and double metatarsal osteotomy for hallux valgus with an increased distal metatarsal articular angle (DMAA). From October 2008 to December 2012, first metatarsal osteotomies were performed in 64 patients (69 feet) with symptomatic hallux valgus associated with an increased DMAA. Proximal chevron with Akin osteotomy and lateral soft tissue release was performed in 46 feet (PCO group); double metatarsal osteotomy and Akin osteotomy without lateral soft tissue release was performed in 23 feet (DMO group). Clinical assessments were performed using the American Orthopaedic Foot and Ankle Society (AOFAS) scale and visual analog scale (VAS). The hallux valgus angles, intermetatarsal angles, sesamoid positions, metatarsus adductus angles, and DMAAs were compared at different postoperative times. Postoperative shortening of first the metatarsal and complications were compared. The mean AOFAS scale and VAS scores showed significant improvement in both groups after surgery; however, no significant difference was observed between the 2 groups. The immediate postoperative hallux valgus angle and sesamoid position were significantly larger in DMO group; however, no intergroup difference was observed at the last follow-up visit, with the hallux valgus angle gradually increasing in the PCO group. The postoperative DMAA was significantly smaller in the DMO group. The mean shortening of the first metatarsal after surgery was significantly larger in the DMO group than in the PCO group. Transfer metatarsalgia developed in 1 foot (2.2%) in the PCO group and 2 feet (8.7%) in the DMO group. Partial avascular necrosis of the metatarsal head with advanced arthritis of the first metatarsophalangeal joint developed in 1 foot (4.3%) in the DMO group. In conclusion, no differences in the clinical and radiographic results were observed between the 2 groups for hallux valgus deformity with an increased DMAA. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Hofstaetter, S G; Schuh, R; Trieb, K; Trnka, H J
2012-12-01
This prospective study examined the clinical and radiological results of the Chevron osteotomy with screw fixation and distal soft tissue release up to an intermetatarsal angle of 19°. Furthermore, the results are presented for patients over the age of 70 years, and whether or not there is a higher complication rate. 86 feet of patients between 23 and 81 years were included in the study. Apart from the overall group, a group with an intermetatarsal angle of 16° to 19° and a group of patients over 70 years old were eavaluated. They were evaluated preoperatively and at follow-up after an average of 3.3 years according to the American Orthopaedic Foot and Ankle Society score. The AOFAS score showed a significant improvement from 55 points preoperatively to 90 points at follow-up. The preoperative hallux valgus angle decreased significantly from 32° to 5° and the preoperative intermetatarsal angle decreased from 14° to 6°. Patient satisfaction in the overall group was rated in 92 % as excellent or good. Also, the patient group with 16° to 19° angles and the patients over 70 years showed a significant improvement of clinical and radiological parameters. The complication rate was very low in all groups. The results show that the Chevron osteotomy is a very good surgical technique with few complications for the correction of splay foot with hallux valgus deformity. We showed that by using the modified technique with a long plantar arm, an excessive soft tissue release and screw fixation, the indication can be extended up to an intermetatarsal angle of 19° when using screw fixation. Furthermore the patients over 70 years of age showed a significant improvement of clinical and radiological parameters without serious complications such as avascular necrosis or dislocation of the metatarsal head. Georg Thieme Verlag KG Stuttgart · New York.
Fischer-Tropsch fuel for use by the U.S. military as battlefield-use fuel of the future
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delanie Lamprecht
2007-06-15
The United States Department of Defense (DoD) has been interested in low-sulfur, environmentally cleaner Fischer-Tropsch (FT) fuels since 2001 because they want to be less dependent upon foreign crude oil and ensure the security of the supply. A three-phase Joint Battlefield-Use Fuel of the Future (BUFF) program was initiated to evaluate, demonstrate, certify, and implement turbine fuels produced from alternative energy resources for use in all of its gas turbine and diesel engine applications. Sasol Synfuels International (Pty) Ltd. and Sasol Chevron Holdings Ltd., among others, were invited to participate in the program with the objective to supply the DoDmore » with a FT BUFF that conforms to Jet Propulsion 8 (JP-8) and JP-5 fuel volatility and low-temperature fluidity requirements. Although the DoD is more interested in coal-to-liquid (CTL) technology, the product from a gas-to-liquid (GTL) Products Work-Up Demonstration Unit in Sasolburg, South Africa, was used to evaluate (on a bench scale) the possibility of producing a BUFF fraction from the Sasol Slurry Phase Distillate (Sasol SPD) low-temperature FT (LTFT) process and Chevron Isocracking technology. It was concluded from the study that the production of a synthetic FT BUFF is feasible using the Sasol SPD LTFT technology together with the current Chevron isocracking technology. The product yield for a BUFF conforming to JP-8 requirements is 30 vol % of the fractionator feed, whereas the product yield for a BUFF conforming to the JP-5 volatility requirement is slightly less than 22 vol % of the fractionator feed. Also concluded from the study was that the end point of the Sasol SPD LTFT BUFF will be restricted by the freezing point requirement of the DoD and not the maximum viscosity requirement. One would therefore need to optimize the hydrocracking process conditions to increase the Sasol SPD LTFT BUFF product yield. 16 refs., 8 figs., 6 tabs.« less
NASA Technical Reports Server (NTRS)
2005-01-01
Saturn's turbulent atmosphere is reminiscent of a Van Gogh painting in this view from Cassini. However, unlike the famous impressionist painter, Cassini records the world precisely as it appears to the spacecraft's cameras. The feathery band that cuts across from the upper left corner to the right side of this scene has a chevron, or arrow, shape near the right. The center of the chevron is located at the latitude (about 28 degrees South) of an eastward-flowing zonal jet in the atmosphere. Counter-flowing eastward and westward jets are the dominant dynamic features seen in the giant planet atmospheres. A chevron-shaped feature with the tip pointed east means that this is a local maximum in the eastward wind and a region of horizontal wind shear, where clouds to the north and south of the jet are being swept back by the slower currents on the sides of the jet. The image was taken in visible light with the Cassini spacecraft narrow-angle camera on July 6, 2005, at a distance of approximately 2.5 million kilometers (1.5 million miles) from Saturn using a filter sensitive to wavelengths of infrared light centered at 727 nanometers. The image scale is 14 kilometers (9 miles) per pixel. The Cassini-Huygens mission is a cooperative project of NASA, the European Space Agency and the Italian Space Agency. The Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the mission for NASA's Science Mission Directorate, Washington, D.C. The Cassini orbiter and its two onboard cameras were designed, developed and assembled at JPL. The imaging operations center is based at the Space Science Institute in Boulder, Colo. For more information about the Cassini-Huygens mission visit http://saturn.jpl.nasa.gov . The Cassini imaging team homepage is at http://ciclops.org .Permanent field plot methodology and equipment
Thomas G. Cole
1993-01-01
Long-term research into the composition, phenology, yield, and growth rates of agroforests can be accomplished with the use of permanent field plots. The periodic remeasurement of these plots provides researchers a quantitative measure of what changes occur over time in indigenous agroforestry systems.
NASA Astrophysics Data System (ADS)
Armston, J.; Marselis, S.; Hancock, S.; Duncanson, L.; Tang, H.; Kellner, J. R.; Calders, K.; Disney, M.; Dubayah, R.
2017-12-01
The NASA Global Ecosystem Dynamics Investigation (GEDI) will place a multi-beam waveform lidar instrument on the International Space Station (ISS) to provide measurements of forest vertical structure globally. These measurements of structure will underpin empirical modelling of above ground biomass density (AGBD) at the scale of individual GEDI lidar footprints (25m diameter). The GEDI pre-launch calibration strategy for footprint level models relies on linking AGBD estimates from ground plots with GEDI lidar waveforms simulated from coincident discrete return airborne laser scanning data. Currently available ground plot data have variable and often large uncertainty at the spatial resolution of GEDI footprints due to poor colocation, allometric model error, sample size and plot edge effects. The relative importance of these sources of uncertainty partly depends on the quality of ground measurements and region. It is usually difficult to know the magnitude of these uncertainties a priori so a common approach to mitigate their influence on model training is to aggregate ground plot and waveform lidar data to a coarser spatial scale (0.25-1ha). Here we examine the impacts of these principal sources of uncertainty using a 3D simulation approach. Sets of realistic tree models generated from terrestrial laser scanning (TLS) data or parametric modelling matched to tree inventory data were assembled from four contrasting forest plots across tropical rainforest, deciduous temperate forest, and sclerophyll eucalypt woodland sites. These tree models were used to simulate geometrically explicit 3D scenes with variable tree density, size class and spatial distribution. GEDI lidar waveforms are simulated over ground plots within these scenes using monte carlo ray tracing, allowing the impact of varying ground plot and waveform colocation error, forest structure and edge effects on the relationship between ground plot AGBD and GEDI lidar waveforms to be directly assessed. We quantify the sensitivity of calibration equations relating GEDI lidar structure measurements and AGBD to these factors at a range of spatial scales (0.0625-1ha) and discuss the implications for the expanding use of existing in situ ground plot data by GEDI.
Partitioning soil respiration: examining the artifacts of the trenching method.
NASA Astrophysics Data System (ADS)
Savage, K. E.; Davidson, E. A.; Finzi, A.; Giasson, M. A.; Wehr, R. A.
2014-12-01
Soil respiration (Rs) is a combination of autotrophic (Ra) and heterotrophic respiration (Rh). Several methods have been developed to tease out the components of Rs, such as isotopic analyses, and removing Ra input through tree girdling and root exclusion experiments. Trenching involves severing the rooting system surrounding a plot to remove the Ra component within the plot. This method has some potential limitations. Reduced water uptake in trenched plots could change soil water content, which is one of the environmental controllers of Rs in many ecosystems. Eliminating root inputs could reduce heterotrophic decomposition of SOM via lack of priming. On the other hand, the severed dead roots may temporarily increase available carbon substrate for Rh. At the Harvard Forest, MA, we used the trenching method to partition Rs into its components Ra and Rh. Pre-trenched Rs was measured from spring to fall of 2012. In late fall of 2012, a trench was excavated to 1m depth around a 5x5m area, severing all roots. Plastic tarp was placed along the trench walls and then backfilled. Four automated Rs chambers were placed in the trenched plot and four in an un-trenched plot. Respiration was measured hourly for each chamber along with soil temperature and moisture from spring through fall of 2013 and 2014. Eighty root decomposition bags were placed in the organic soil horizon of the trenched (40) and un-trenched (40) plots at the time of trenching in 2012 and measured in 2013 and 2014. These data are being used to estimate the size and duration of any artifact due to root death. As expected, Rs was lower in the trenched plot (Rh only) than in the un-trenched plot (Rh + Ra) in 2013, but the reverse was unexpectedly observed during a period of low precipitation in 2014. High rates of ET combined with below-average precipitation dried the un-trenched plot to a point where Rh was inhibited, whereas less ET allowed the un-trenched plots to remain measurably wetter.
Zhang, Yu-Hang; Bi, Da-Wei; Chen, Yi-Min; Zu, Gang; Ma, Hai-Tao
2018-03-25
To explore clinical application of three-dimensional printing technology to design individual angle section on Chevron of hallux valgus osteotomy. From May 2013 to May 2016, 47 patients(66 feet) with mild to moderate hallux valgus treated by Chevron osteotomy according to different preoperative design were divided into computer osteotomy group(group A) and traditional osteotomy group(group B). In group A, there were 25 patients (33 feet), including 4 males(5 feet) and 21 females(28 feet) with an average age of (47.88±6.08) years old, average weight IMA was (13.58±1.15) degree, AOFAS score was 59.00±5.86, and treated individual 3D printing technology to design operation scheme. While in group B, there were 22 patients (33 feet), including 3 males (3 feet) and 19 females (28 feet) with an average age of (48.16±6.16) years old, average weight IMA was(13.51±1.14) degree, AOFAS score was 60.67±5.85, and treated with osteotomy according to surgical experience. Operation time, blood loss, hospital stays, VAS score at 1 week after operation, wound healing and improvement of postoperative weight-bearing intermetatarsal angle(IMA) were compared between two groups, AOFAS score system was used to evaluate ankle function after surgery. There was no significant difference in following-up between group A 12.41±2.32 and group B 11.73±2.76. There was 1 patient in group B were excluded. Others perform good wounds healing on the first stage after operation. There were no significant differences in operation time, blood loss, hospital stays and VAS score at 1 week after operation( P <0.05); IMA in group A was (5.21±0.88)°, (6.42±0.85)° in group B, and had significant differences between two groups ( t =5.68, P <0.05). There was obvious meaning in AOFAS score between group A 88.15±5.19 and group B 82.90±5.01( t =4.14, P <0.05). Fourteen feet in group A obtained excellent results and 19 feet good, while 5 feet in group B obtained excellent results and 27 feet good. Compared with traditional osteotomy group, three-dimensional printing technology to design individual angle section on Chevron of hallux valgus osteotomy could better correct IMA, improve postoperative foot function, and it is a kind of individualized and digital method to design operation. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
Sediment production from forest roads with wheel ruts
Randy B. Foltz; Edward R. Burroughs
1990-01-01
Artificial rainfall was applied to two sets of paired plots 30.5 m long by 1.52 m wide, each set on a different soil type. One plot in each set contained a wheel rut while the other did not. Measurements of water and sediment yield on rutted plots showed sediment production declined with cumulative runoff while unrutted plots did not show a significant sediment...
Measuring Polanyi Potentials for Chemsorb 1000 and Chemsorb 3800
NASA Technical Reports Server (NTRS)
Monje, Oscar; Surma, Jan M.; Kayatin, Matthew J.; Perry, Jay L.
2016-01-01
Polanyi adsorption potential plots are used to predict the adsorptive capacities of volatile organic compounds onto activated carbons. The design and construction of a test rig for measuring equilibrium adsorption capacities suitable for constructing Polanyi adsorption potential plots for candidate sorbents suitable for use in ECLS systems is presented. The adsorptive capacities of Chemsorb(TradeMark) 1000 and Chemsorb(TradeMark) 800 for ethanol and acetone were measured. The capacities and Polanyi adsorption potential plots for these commercially-available sorbents were compared to that of Barnebey Sutcliffe Type 3032, an acid-impregnated activated carbon utilized aboard the International Space Station.
Study of fracture toughness of ZrO2 ceramics
NASA Astrophysics Data System (ADS)
Deryugin, Yevgeny; Narkevich, Natalya; Vlasov, Ilya; Panin, Victor; Danilenko, Igor; Schmauder, Siegfried
2017-12-01
The fracture toughness characteristics of ZrO2ceramics were determined experimentally using an original technique of wedging small-sized chevron notch specimens developed at the Institute of Strength Physics and Materials Science SB RAS (Russia) in the laboratory of physical mesomechanics of materials and non-destructive testing. Measurements have shown that inelastic displacements can be more than 22% of the total displacement of the consoles by the time of the specimen failure. The effect of the Y2O3 stabilizer on the critical stress intensity factor KIc was verified. It was shown that an increase in the Y2O3 stabilizer content from 3 to 8% significantly decreases the fracture toughness. The stress intensity factor KIc falls within the range from 5.7 to 2.35 MPa m1/2.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Z.; Taya, M.; Dunn, M.L.
A hybrid experimental-numerical approach has been used to measure the fracture resistance of a sandwich structure consisting of a 304 stainless steel/partially stabilized zirconia ceramic-matrix composite crack-arresting layer embedded in a partially stabilized zirconia ceramic specimen. The mode 1 fracture toughness increases significantly when the crack propagates from the ceramic into the ceramic-matrix composite region. The increased toughening due to the stainless steel particles is explained reasonably well by a toughening model based on processing-induced thermal residual stresses. In addition, several experimental modifications were made to the chevron-notch wedge-loaded double cantilever beam specimen to overcome numerous problems encountered in generatingmore » a precrack in the small, brittle specimens used in this study.« less
Larch Litter Removal Has No Significant Effect On Runoff
Richard S. Startz; David N. Tolsted
1974-01-01
Runoff was measured on paired litter-removed, litter-left plots in an 11-year-old European larch plantation. On five of the six pairs of plots, the plot with the litter left intact yielded more runoff. however, the differences were neither statistically nor hydrologically significant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
W. C. Adams
2007-11-20
During the period of October 2 and 3, 2007, the Oak Ridge Institute for Science and Education (ORISE) performed confirmatory radiological survey activities which included gamma surface scans within Area B1S/B2S and the collection of soil samples from these areas.
Flow Solution for Advanced Separate Flow Nozzles Response A: Structured Grid Navier-Stokes Approach
NASA Technical Reports Server (NTRS)
Kenzakowski, D. C.; Shipman, J.; Dash, S. M.; Saiyed, Naseem (Technical Monitor)
2001-01-01
NASA Glenn Research Center funded a computational study to investigate the effect of chevrons and tabs on the exhaust plume from separate flow nozzles. Numerical studies were conducted at typical takeoff power with 0.28 M flight speed. Report provides numerical data and insights into the mechanisms responsible for increased mixing.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-12
... Authorization To Export Liquefied Natural Gas AGENCY: Office of Fossil Energy, DOE. ACTION: Notice of application. SUMMARY: The Office of Fossil Energy (FE) of the Department of Energy (DOE) gives notice of... Security and Supply, Office of Fossil Energy, Forrestal Building, Room 3E-042, 1000 Independence Avenue, SW...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-06
... Authorization To Export Previously Imported Liquefied Natural Gas on a Short-Term Basis AGENCY: Office of Fossil Energy, DOE. ACTION: Notice of application. SUMMARY: The Office of Fossil Energy (FE) of the Department.... Department of Energy (FE-34), Office of Oil and Gas Global Security and Supply, Office of Fossil Energy...
1995-08-01
7515 (818) 791-8805 (FAX) (415) 742-7540 (FAX) CHEVRON CORPORATION HUISH DETERGENTS, INC. CHARLOTTE R. FARBER DON GOLLADAY 225 BUSH STREET P.O. BOX 25057...USA) TEXAS INSTRUMENTS KENT BOSSART ZAK KARAMALLY 1701 PENNSYLVANIA AVE., NW #500 TEXAS INSTRUMENTS WASHINGTON, DC 20006 ZAK KARAMALLY 202-861-0668 P
From fuzzy recurrence plots to scalable recurrence networks of time series
NASA Astrophysics Data System (ADS)
Pham, Tuan D.
2017-04-01
Recurrence networks, which are derived from recurrence plots of nonlinear time series, enable the extraction of hidden features of complex dynamical systems. Because fuzzy recurrence plots are represented as grayscale images, this paper presents a variety of texture features that can be extracted from fuzzy recurrence plots. Based on the notion of fuzzy recurrence plots, defuzzified, undirected, and unweighted recurrence networks are introduced. Network measures can be computed for defuzzified recurrence networks that are scalable to meet the demand for the network-based analysis of big data.
Balsillie, J.H.; Donoghue, J.F.; Butler, K.M.; Koch, J.L.
2002-01-01
Two-dimensional plotting tools can be of invaluable assistance in analytical scientific pursuits, and have been widely used in the analysis and interpretation of sedimentologic data. We consider, in this work, the use of arithmetic probability paper (APP). Most statistical computer applications do not allow for the generation of APP plots, because of apparent intractable nonlinearity of the percentile (or probability) axis of the plot. We have solved this problem by identifying an equation(s) for determining plotting positions of Gaussian percentiles (or probabilities), so that APP plots can easily be computer generated. An EXCEL example is presented, and a programmed, simple-to-use EXCEL application template is hereby made publicly available, whereby a complete granulometric analysis including data listing, moment measure calculations, and frequency and cumulative APP plots, is automatically produced.
NASA Astrophysics Data System (ADS)
Vestin, P.; Mölder, M.; Sundqvist, E.; Båth, A.; Lehner, I.; Weslien, P.; Klemedtsson, L.; Lindroth, A.
2015-12-01
In order to assess the effects of different management practices on the exchange of greenhouse gases (GHG), it is desirable to perform repeated and parallel measurements on both experimental and control plots. Here we demonstrate how a system system combining eddy covariance and gradient techniques can be used to perform this assessment in a managed forest ecosystem.The net effects of clear-cutting and stump harvesting on GHG fluxes were studied at the ICOS site Norunda, Sweden. Micrometeorological measurements (i.e., flux-gradient measurements in 3 m tall towers) allowed for quantification of CO2, CH4 and H2O fluxes (from May 2010) as well as N2O and H2O fluxes (from June 2011) at two stump harvested plots and two control plots. There was one wetter and one drier plot of each treatment. Air was continuously sampled at two heights in the towers and gas concentrations were analyzed for CH4, CO2, H2O (LGR DLT-100, Los Gatos Research) and N2O, H2O (QCL Mini Monitor, Aerodyne Research). Friction velocities and sensible heat fluxes were measured by sonic anemometers (Gill Windmaster, Gill Instruments Ltd). Automatic chamber measurements (CO2, CH4, H2O) were carried out in the adjacent forest stand and at the clear-cut during 2010.Average CO2 emissions for the first year ranged between 14.4-20.2 ton CO2 ha-1 yr-1. The clear-cut became waterlogged after harvest and a comparison of flux-gradient data and chamber data (from the adjacent forest stand) indicated a switch from a weak CH4 sink to a significant source at all plots. The CH4 emissions ranged between 0.8-4.5 ton CO2-eq. ha-1 yr-1. N2O emissions ranged between 0.4-2.6 ton CO2-eq. ha-1 yr-1. Enhanced N2O emission on the drier stump harvested plot was the only clear treatment effect on GHG fluxes that was observed. Mean CH4 and N2O emissions for the first year of measurements amounted up to 29% and 20% of the mean annual CO2 emissions, respectively. This highlights the importance of including all GHGs when assessing the climate impacts of different forest management options. Our results show that continuous multi-plot measurements of the main GHGs are possible also at sites where GHG fluxes are low, at a reasonable cost and with reduced plot inter-comparison uncertainties.
NASA Astrophysics Data System (ADS)
Baryła, A.; Pierzgalski, E.; Karczmarczyk, A.
2009-04-01
oil losses due to water erosion not only decrease of soil fertility but also influence on pollution of water bodies. One of the method for limitation of water erosion process is protected soil management and choose suitable plants which requires knowledge about effect and mechanism of erosion under different environmental conditions. The results of measurements of quantity and quality of soil losses from three experimental plots are given in the article. Plots were located in Experimental Agricultural Station Puczniew in central part of Poland. Surface soil layer on the plots had mechanical composition of medium loam soil. On two plots grass and barley were planted. Third plot was used as fallow and tilled land. Measurements were carried out four times in the period May-October 2007. Physical and chemical composition of washed soil material was analyzed.
Emerson, Douglas G.
1994-01-01
A model that simulates heat and water transfer in soils during freezing and thawing periods was developed and incorporated into the U.S. Geological Survey's Precipitation-Runoff Modeling System. The model's transfer of heat is based on an equation developed from Fourier's equation for heat flux. The model's transfer of water within the soil profile is based on the concept of capillary forces. Field capacity and infiltration rate can vary throughout the freezing and thawing period, depending on soil conditions and rate and timing of snowmelt. The model can be used to determine the effects of seasonally frozen soils on ground-water recharge and surface-water runoff. Data collected for two winters, 1985-86 and 1986-87, on three runoff plots were used to calibrate and verify the model. The winter of 1985-86 was colder than normal, and snow cover was continuous throughout the winter. The winter of 1986-87 was warmer than normal, and snow accumulated for only short periods of several days. as the criteria for determining the degree of agreement between simulated and measured data. The model was calibrated using the 1985-86 data for plot 2. The calibration simulation agreed closely with the measured data. The verification simulations for plots 1 and 3 using the 1985-86 data and for plots 1 and 2 using the 1986-87 data agreed closely with the measured data. The verification simulation for plot 3 using the 1986-87 data did not agree closely. The recalibration simulations for plots 1 and 3 using the 1985-86 data indicated little improvement because the verification simulations for plots 1 and 3 already agreed closely with the measured data.
Emerson, Douglas G.
1991-01-01
A model that simulates heat and water transfer in soils during freezing and thawing periods was developed and incorporated into the U.S. Geological Survey's Precipitation-Runoff Modeling System. The transfer of heat 1s based on an equation developed from Fourier's equation for heat flux. Field capacity and infiltration rate can vary throughout the freezing and thawing period, depending on soil conditions and rate and timing of snowmelt. The transfer of water within the soil profile is based on the concept of capillary forces. The model can be used to determine the effects of seasonally frozen soils on ground-water recharge and surface-water runoff. Data collected for two winters, 1985-86 and 1986-87, on three runoff plots were used to calibrate and verify the model. The winter of 1985-86 was colder than normal and snow cover was continuous throughout the winter. The winter of 1986-87 was wanner than normal and snow accumulated for only short periods of several days.Runoff, snowmelt, and frost depths were used as the criteria for determining the degree of agreement between simulated and measured data. The model was calibrated using the 1985-86 data for plot 2. The calibration simulation agreed closely with the measured data. The verification simulations for plots 1 and 3 using the 1985-86 data and for plots 1 and 2 using the 1986-87 data agreed closely with the measured data. The verification simulation for plot 3 using the 1986-87 data did not agree closely. The recalibratlon simulations for plots 1 and 3 using the 1985-86 data Indicated small improvement because the verification simulations for plots 1 and 3 already agreed closely with the measured data.
Hydrologic Impact of Straw Mulch On Runoff from a Burned Area for Various Soil Water Content
NASA Astrophysics Data System (ADS)
Carnicle, M. M.; Moody, J. A.; Ahlstrom, A. K.
2011-12-01
Mountainous watersheds often exhibit increases in runoff and flash floods after wildfires. During 11 days of September 2010, the Fourmile Canyon wildfire burned 2500 hectares of the foothills of the Rocky Mountains near Boulder, Colorado. In an effort to minimize the risk of flash floods after the wildfire, Boulder County aerially applied straw mulch on high-risk areas selected primarily on the basis of their slopes and burn severities. The purpose of this research is to investigate the hydrologic response, specifically runoff, of a burned area where straw mulch is applied. We measured the runoff, at different soil water contents, from 0.8-m diameter plots. Paired plots were installed in June 2011 in a basin burned by the Fourmile Canyon Fire. Two sets of bounded, paired plot (two control and two experimental plots) were calibrated for 35 days without straw on either plot by measuring volumetric soil water content 2-3 times per week and measuring total runoff from each storm. Straw (5 cm thick) was added to the two experimental plots on 19 July 2011 and also to the funnels of two visual rain gages in order to measure the amount of rainfall absorbed by the straw. Initial results during the calibration period showed nearly linear relations between the volumetric soil water content of the control and experimental plots. The regression line for the runoff from the control versus the runoff from the experiment plot did not fit a linear trend; the variability may have been caused by two intense storms, which produced runoff that exceeded the capacity of the runoff gages. Also, during the calibration period, when soil water content was low the runoff coefficients were high. It is anticipated that the final results will show that the total runoff is greater on plots with no straw compared to those with straw, under conditions of various antecedent soil water content. We are continuing to collect data during the summer of 2011 to test this hypothesis.
Miller, M.E.; Belnap, J.; Beatty, S.W.; Webb, B.L.
2006-01-01
We used ion-exchange resin bags to investigate effects of water additions, chemical amendments, and plant presence on in situ measures of nutrient bioavailability in conjunction with a study examining soil controls of ecosystem invasion by the exotic annual grass Bromus tectorum L. At five dryland sites in southeastern Utah, USA, resin bags were buried in experimental plots randomly assigned to combinations of two watering treatments (wet and dry), four chemical-amendment treatments (KCl, MgO, CaO, and no amendment), and four plant treatments (B. tectorum alone, the perennial bunchgrass Stipa hymenoides R. & S. alone, B. tectorum and S. hymenoides together, and no plants). Resin bags were initially buried in September 1997; replaced in January, April, and June 1998; and removed at the end of the study in October 1998. When averaged across watering treatments, plots receiving KCl applications had lower resin-bag NO 3- than plots receiving no chemical amendments during three of four measurement periods-probably due to NO 3- displacement from resin bags by Cl- ions. During the January-April period, KCl application in wet plots (but not dry plots) decreased resin-bag NH 4+ and increased resin-bag NO 3- . This interaction effect likely resulted from displacement of NH 4+ from resins by K+ ions, followed by nitrification and enhanced NO 3- capture by resin bags. In plots not receiving KCl applications, resin-bag NH 4+ was higher in wet plots than in dry plots during the same period. During the January-April period, resin-bag measures for carbonate-related ions HPO 42- , Ca2+, and Mn2+ tended to be greater in the presence of B. tectorum than in the absence of B. tectorum. This trend was evident only in wet plots where B. tectorum densities were much higher than in dry plots. We attribute this pattern to the mobilization of carbonate-associated ions by root exudates of B. tectorum. These findings indicate the importance of considering potential indirect effects of soil amendments performed in conjunction with resource-limitation studies, and they suggest the need for further research concerning nutrient acquisition mechanisms of B. tectorum. ?? 2006 Springer Science+Business Media B.V.
Anell, Anders; Hagberg, Oskar; Liedberg, Fredrik; Ryden, Stefan
2016-12-01
Comparison of provider performance is commonly used to inform health care decision-making. Little attention has been paid to how data presentations influence decisions. This study analyzes differences in suggested actions by decision-makers informed by league tables or funnel plots. Decision-makers were invited to a survey and randomized to compare hospital performance using either league tables or funnel plots for four different measures within the area of cancer care. For each measure, decision-makers were asked to suggest actions towards 12-16 hospitals (no action, ask for more information, intervene) and provide feedback related to whether the information provided had been useful. Swedish health care. Two hundred and twenty-one decision-makers at administrative and clinical levels. Data presentations in the form of league tables or funnel plots. Number of actions suggested by participants. Proportion of appropriate actions. For all four measures, decision-makers tended to suggest more actions based on the information provided in league tables compared to funnel plots (44% vs. 21%, P < 0.001). Actions were on average more appropriate for funnel plots. However, when using funnel plots, decision-makers more often missed to react even when appropriate. The form of data presentation had an influence on decision-making. With league tables, decision-makers tended to suggest more actions compared to funnel plots. A difference in sensitivity and specificity conditioned by the form of presentation could also be identified, with different implications depending on the purpose of comparisons. Explanations and visualization aids are needed to support appropriate actions. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Karmakar, Chandan K; Khandoker, Ahsan H; Voss, Andreas; Palaniswami, Marimuthu
2011-03-03
A novel descriptor (Complex Correlation Measure (CCM)) for measuring the variability in the temporal structure of Poincaré plot has been developed to characterize or distinguish between Poincaré plots with similar shapes. This study was designed to assess the changes in temporal structure of the Poincaré plot using CCM during atropine infusion, 70° head-up tilt and scopolamine administration in healthy human subjects. CCM quantifies the point-to-point variation of the signal rather than gross description of the Poincaré plot. The physiological relevance of CCM was demonstrated by comparing the changes in CCM values with autonomic perturbation during all phases of the experiment. The sensitivities of short term variability (SD1), long term variability (SD2) and variability in temporal structure (CCM) were analyzed by changing the temporal structure by shuffling the sequences of points of the Poincaré plot. Surrogate analysis was used to show CCM as a measure of changes in temporal structure rather than random noise and sensitivity of CCM with changes in parasympathetic activity. CCM was found to be most sensitive to changes in temporal structure of the Poincaré plot as compared to SD1 and SD2. The values of all descriptors decreased with decrease in parasympathetic activity during atropine infusion and 70° head-up tilt phase. In contrast, values of all descriptors increased with increase in parasympathetic activity during scopolamine administration. The concordant reduction and enhancement in CCM values with parasympathetic activity indicates that the temporal variability of Poincaré plot is modulated by the parasympathetic activity which correlates with changes in CCM values. CCM is more sensitive than SD1 and SD2 to changes of parasympathetic activity.
Permanent-plot procedures for silvicultural and yield research.
Robert O. Curtis; David D. Marshall
2005-01-01
This paper reviews purposes and procedures for establishing and maintaining permanent plots for silvicultural and yield research, sampling and plot design, common errors, and procedures for measuring and recording data. It is a revision and update of a 1983 publication. Although some details are specific to coastal Pacific Northwest conditions, most of the material is...
National FIA plot intensification procedure report
Jock A. Blackard; Paul L. Patterson
2014-01-01
The Forest Inventory and Analysis (FIA) program of the U.S. Forest Service (USFS) measures a spatially distributed base grid of forest inventory plots across the United States. The sampling intensity of plots may be increased in some regions when warranted by specific inventory objectives. Several intensification methods have been developed within FIA and USFS National...
AmeriFlux US-ARc ARM Southern Great Plains control site- Lamont
Torn, Margaret [Lawrence Berkeley National Laboratory
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-ARc ARM Southern Great Plains control site- Lamont. Site Description - The ARM SGP Control site is located in the native tallgrass prairies of the USDA Grazinglands Research Laboratory near El Reno, OK. One of two adjacent 35 ha plots with identical towers, measurements at the US-ARc unburned plot are used as the experimental control. The second plot, US-Arb, was burned on 2005/03/08. Measurement comparisons between the control and burn plot are used to address questions regarding the effects of burning activities on carbon fluxes. The region evaded burning activities for at least 15 years. Current disturbances consist of only light grazing activities.
Effect of Control Mode and Test Rate on the Measured Fracture Toughness of Advanced Ceramics
NASA Technical Reports Server (NTRS)
Hausmann, Bronson D.; Salem, Jonathan A.
2018-01-01
The effects of control mode and test rate on the measured fracture toughness of ceramics were evaluated by using chevron-notched flexure specimens in accordance with ASTM C1421. The use of stroke control gave consistent results with about 2% (statistically insignificant) variation in measured fracture toughness for a very wide range of rates (0.005 to 0.5 mm/min). Use of strain or crack mouth opening displacement (CMOD) control gave approx. 5% (statistically significant) variation over a very wide range of rates (1 to 80 µm/m/s), with the measurements being a function of rate. However, the rate effect was eliminated by use of dry nitrogen, implying a stress corrosion effect rather than a stability effect. With the use of a nitrogen environment during strain controlled tests, fracture toughness values were within about 1% over a wide range of rates (1 to 80 micons/m/s). CMOD or strain control did allow stable crack extension well past maximum force, and thus is preferred for energy calculations. The effort is being used to confirm recommendations in ASTM Test Method C1421 on fracture toughness measurement.
Rates and Implications of Rainfall Interception in a Coastal Redwood Forest
Leslie M. Reid; Jack Lewis
2007-01-01
Throughfall was measured for a year at five-min intervals in 11 collectors randomly located on two plots in a second-growth redwood forest at the Caspar Creek Experimental Watersheds. Monitoring at one plot continued two more years, during which stemflow from 24 trees was also measured. Comparison of throughfall and stemflow to rainfall measured in adjacent clearings...
Quality control of measurements made on fixed-area sample plots
Ola Lindgren
2000-01-01
The paper describes results from a large program for quality control of forest measurements. The performance of 87 surveyors was evaluated. Tree heights were usually measured well, whereas the counting of tree-rings on increment cores was a source of considerable bias for many surveyors. During tree count on sample plots, many surveyors had a tendency to forget trees,...
Turbulence Measurements of Separate Flow Nozzles with Mixing Enhancement Features
NASA Technical Reports Server (NTRS)
Bridges, James; Wernet, Mark P.
2002-01-01
Comparison of turbulence data taken in three separate flow nozzles, two with mixing enhancement features on their core nozzle, shows how the mixing enhancement features modify turbulence to reduce jet noise. The three nozzles measured were the baseline axisymmetric nozzle 3BB, the alternating chevron nozzle, 3A12B, with 6-fold symmetry, and the flipper tab nozzle 3T24B also with 6-fold symmetry. The data presented show the differences in turbulence characteristics produced by the geometric differences in the nozzles, with emphasis on those characteristics of interest in jet noise. Among the significant findings: the enhanced mixing devices reduce turbulence in the jet mixing region while increasing it in the fan/core shear layer, the ratios of turbulence components are significantly altered by the mixing devices, and the integral lengthscales do not conform to any turbulence model yet proposed. These findings should provide guidance for modeling the statistical properties of turbulence to improve jet noise prediction.
NASA Astrophysics Data System (ADS)
Irby, Victor D.
2004-09-01
The concept and subsequent experimental verification of the proportionality between pulse amplitude and detector transit time for microchannel-plate detectors is presented. This discovery has led to considerable improvement in the overall timing resolution for detection of high-energy ggr-photons. Utilizing a 22Na positron source, a full width half maximum (FWHM) timing resolution of 138 ps has been achieved. This FWHM includes detector transit-time spread for both chevron-stack-type detectors, timing spread due to uncertainties in annihilation location, all electronic uncertainty and any remaining quantum mechanical uncertainty. The first measurement of the minimum quantum uncertainty in the time interval between detection of the two annihilation photons is reported. The experimental results give strong evidence against instantaneous spatial localization of ggr-photons due to measurement-induced nonlocal quantum wavefunction collapse. The experimental results are also the first that imply momentum is conserved only after the quantum uncertainty in time has elapsed (Yukawa H 1935 Proc. Phys. Math. Soc. Japan 17 48).
NASA Astrophysics Data System (ADS)
Melliana, Armen, Yusrizal, Akmal, Syarifah
2017-11-01
PT Nira Murni construction is a contractor of PT Chevron Pacific Indonesia which engaged in contractor, fabrication, maintenance construction suppliers, and labor services. The high of accident rate in this company is caused the lack of awareness of workplace safety. Therefore, it requires an effort to reduce the accident rate on the company so that the financial losses can be minimized. In this study, Safe T-Score method is used to analyze the accident rate by measuring the level of frequency. Analysis is continued using risk management methods which identify hazards, risk measurement and risk management. The last analysis uses Job safety analysis (JSA) which will identify the effect of accidents. From the result of this study can be concluded that Job Safety Analysis (JSA) methods has not been implemented properly. Therefore, JSA method needs to follow-up in the next study, so that can be well applied as prevention of occupational accidents.
Separation dynamics of dense dispersions in laminar pipe flows: An experimental and numerical study
NASA Astrophysics Data System (ADS)
Voulgaropoulos, Victor; Jamshidi, Rashid; Zainal Abidin, M. I. I.; Angeli, Panagiota
2017-11-01
The physical mechanisms governing the separation of dense liquid dispersed flows in pipes are not well understood. In this work, both experiments and numerical simulations are performed to investigate these mechanisms. Liquid-liquid dispersions are generated using a static mixer and their evolution is studied along a horizontal pipe (26mm ID) at laminar flow and input dispersed phase volume fractions up to 50%. To conduct optical measurements (PLIF and PIV) in the dense dispersions, the refractive index of both liquids is matched. Measurements are carried out at two axial locations downstream the mixer (15D and 135D, where D is the pipe diameter). Homogeneous dispersions, observed at 15D, segregate at 135D. The packing of the drops results in asymmetric velocity profiles and high slip velocities. The mixture approach is used in the numerical simulations, including gravity and shear-induced diffusion of drops. The predictions on separation and on velocity fields agree well with the experiments. Research funded by Chevron.
Accelerated Schools Centers: How To Address Challenges to Institutionalization and Growth.
ERIC Educational Resources Information Center
Meza, James, Jr.
The Accelerated Schools Project (ASP) at the University of New Orleans (UNO) was established in spring 1990, funded by a 3-year grant from Chevron. Beginning with 1 pilot school in 1991, the UNO Accelerated Schools Center has expanded to 36 schools representing 19 school districts in Louisiana and 3 schools from the Memphis City Schools district.…
2013-12-01
21 a. Siberian Pipeline Explosion (1982) ............................21 b. Chevron Emergency Alert...the fifth domain: Are the mouse and keyboard the new weapons of conflict?,” The Economist, July 1, 2010, http://www.economist.com/node/16478792. 15...a. Siberian Pipeline Explosion (1982) In 1982, intruders planted a Trojan horse in the SCADA system that controls the Siberian Pipeline. This is the
American Avocet (Recurvirostra americana)
Ackerman, Joshua T.; Hartman, C. Alex; Herzog, Mark P.; Takekawa, John Y.; Robinson, Julie A.; Oring, Lewis W.; Skorupa, Joseph P.; Boettcher, Ruth; Poole, A.
2013-01-01
This large, striking shorebird with long bluish-gray legs, a long recurved bill, and a black-and-white chevron pattern on its back and wings is one of four Avocet species in the world, the only one with distinct breeding and non-breeding plumages -- its grayish-white head and neck feathers become cinnamon in early spring as birds begin to form pairs and migrate to breeding areas.
Incidence of Negative Appendectomy: Experience From a Company Hospital in Nigeria
Osime, OC; Ajayi, PA
2005-01-01
Objective: The aim of this study was to determine the rate of negative appendectomy in a company hospital in Nigeria. Background: Appendicitis is one of the most common abdominal conditions requiring surgical intervention. Appendectomy, like most surgical procedures, has its complications and therefore should only be undertaken when indicated. Case series have reported the incidence of negative appendectomy in Western nations. The purpose of this retrospective study is to evaluate the incidence of negative appendectomy in a Nigerian hospital, where all the operations were carried out by consultant surgeons. Methods: All case files of patients who received an appendectomy at Chevron Hospital in Warri, Nigeria between January, 1999 and December, 2003 were reviewed. Demographic data, symptoms and signs on presentation, intra-operative findings and histological reports on the excised vermiform appendixes were extracted from the case files and analyzed. Results: The incidence of negative appendectomy in this study was 16.1%; all nine patients that had negative appendectomy were female. Conclusion: The incidence of negative appendectomy observed at Chevron Hospital in Warri, Nigeria is lower than that reported by most studies; one factor may be that all the patients in the present study were evaluated and operated on by consultant surgeons. PMID:20847869
Ballistic thermoelectric properties of nitrogenated holey graphene nanostructures
NASA Astrophysics Data System (ADS)
Cao, Wei; Xiao, Huaping; Ouyang, Tao; Zhong, Jianxin
2017-11-01
In this study, we theoretically investigate the ballistic thermoelectric performance of a new two-dimensional material, nitrogenated holey graphene (NHG), using nonequilibrium Green's function method. The calculations show that compared to graphene, such novel single atomic layer structure exhibits better thermoelectric performance. At room temperature, the stable hole (electron) thermoelectric figure of merit ( Z T ) could approach 0.75 (0.2) and 0.6 (0.2) for zigzag-edged (Z-NHGNRs) and armchair-edged NHGNRs (A-NHGNRs), respectively. To achieve better thermoelectric performance, the effect of geometric engineering (chevron-type nanoribbons and rhomboid quantum dot) on the electronic and phononic transport properties of Z-NHGNRs is further discussed. The results indicate that structure modulation is indeed a viable approach to enhance the thermoelectric properties (the figure of merit could exceed 1.5 and 1.3 for the chevron-type and rhomboid quantum dot system, respectively). On analyzing the transport properties, such improvement on the figure of merit is mainly attributed to the increased Seebeck coefficient and reduced thermal conductance (including both electronic and phononic contributions). Our findings presented in this paper qualify NHG as a promising thermoelectric material and provide theoretical guidance for fabricating the outstanding thermoelectric devices.
Prediction of Central Burst Defects in Copper Wire Drawing Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vega, G.; NEXANS France, NMC Nexans Metallurgy Centre, Boulevard du Marais, BP39, F-62301 Lens; Haddi, A.
2011-01-17
In this study, the prediction of chevron cracks (central bursts) in copper wire drawing process is investigated using experimental and numerical approaches. The conditions of the chevron cracks creation along the wire axis depend on (i) the die angle, the friction coefficient between the die and the wire, (ii) the reduction in crosssectional area of the wire, (iii) the material properties and (iv) the drawing velocity or strain rate. Under various drawing conditions, a numerical simulation for the prediction of central burst defects is presented using an axisymmetric finite element model. This model is based on the application of themore » Cockcroft and Latham fracture criterion. This criterion was used as the damage value to estimate if and where defects will occur during the copper wire drawing. The critical damage value of the material is obtained from a uniaxial tensile test. The results show that the die angle and the reduction ratio have a significant effect on the stress distribution and the maximum damage value. The central bursts are expected to occur when the die angle and reduction ratio reach a critical value. Numerical predictions are compared with experimental observations.« less
[The minimally invasive Chevron and Akin osteotomy (MICA)].
Altenberger, Sebastian; Kriegelstein, Stefanie; Gottschalk, Oliver; Dreyer, Florian; Mehlhorn, Alexander; Röser, Anke; Walther, Markus
2018-04-18
Percutaneous correction of a hallux valgus deformity with or without transfer metatarsalgia. Hallux valgus deformity up to 20° intermetatarsal angle, without instability of the first tarsometatarsal joint. Symptomatic arthritis of the first metatarsophalangeal joint, as well as instability of the first tarsometatarsal joint. Percutaneous performed osteotomy of the distal metatarsal 1 in combination with a medial closing wedge osteotomy of the proximal phalanx of the first toe. The use of a postoperative shoe with a rigid sole allows adapted weight bearing in the first 6 weeks. Active and passive mobilization can start immediately after surgery. The method is very effective to treat even severe deformities with or without metatarsalgia. The amount of correction is similar to open procedures. We recommend cadaver training to become familiar with this technique. Thus, complications such as nerve, vessel or tendon injuries can be avoided. The intraoperative radiation exposure remains significantly elevated even for experienced surgeons. In addition to the aesthetic benefits, there is less soft tissue traumatization compared to conventional open procedures. There is no need of bloodlessness. The minimally invasive Chevron and Akin osteotomy is a safe and powerful technique for the treatment of hallux valgus deformity.
Petroleum developments in North Africa in 1979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nicod, M.A.
In the 6 countries covered by this report, the extent of valid petroleum rights, seismic work, and drilling was nearly the same as in 1978. The success rate of wildcat drilling decreased slightly, to 28% (33% in 1978), with 26 oil or gas discoveries. In southwestern Tunisia, the Amoco Sabrina Nord 1 tested 930 bbl of 39/sup 0/ APl oil from Cambrian-Ordovician sandstones - the first oil to come from lower Paleozoic rocks in Tunisia. First commercial oil from Cambrian-Ordovician rocks in western Libya was discovered by Agip A1-NC40 which flowed 1,400 b/d. Highlight of the year in North Africamore » was in the interior basin of Sudan where the Chevron Abu Gabra 1 tested 900 BOPD of 40/sup 0/ APl oil from Cretaceous rocks; 2 other wells, spudded in late 1979 in the same area, have tested 3,200 and 7,300 b/d, respectively, in early 1980. Discovery well of the interior basin was Chevron Unity 1 which tested small amounts of oil in 1978. Oil production in North Africa in 1979 averaged 3,939,500 b/d compared with 3,802,800 b/d in 1978, an increase of 3.6%.« less
Jauhari, Nidhi; Chopra, Deepak; Chaurasia, Rajan Kumar; Agarwal, Ashutosh
2014-01-01
To determine the surgically induced astigmatism (SIA) in Straight, Frown and Inverted V shape (Chevron) incisions in manual small incision cataract surgery (SICS). A prospective cross sectional study was done on a total of 75 patients aged 40y and above with senile cataract. The patients were randomly divided into three groups (25 each). Each group received a particular type of incision (Straight, Frown or Inverted V shape incisions). Manual SICS with intraocular lens (IOL) implantation was performed. The patients were compared 4wk post operatively for uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA) and SIA. All calculations were performed using the SIA calculator version 2.1, a free software program. The study was analyzed using SPSS version 15.0 statistical analysis software. The study found that 89.5% of patients in Straight incision group, 94.2% in Frown incision group and 95.7% in Inverted V group attained BCVA post-operatively in the range of 6/6 to 6/18. Mean SIA was minimum (-0.88±0.61D×90 degrees) with Inverted V incision which was statistically significant. Inverted V (Chevron) incision gives minimal SIA.
NASA Astrophysics Data System (ADS)
Maaß, Friedrich; Utecht, Manuel; Stremlau, Stephan; Gille, Marie; Schwarz, Jutta; Hecht, Stefan; Klamroth, Tillmann; Tegeder, Petra
2017-07-01
Utilizing suitable precursor molecules, a thermally activated and surface-assisted synthesis results in the formation of defect-free graphene nanoribbons (GNRs), which exhibit electronic properties that are not present in extended graphene. Most importantly, they have a band gap in the order of a few electron volts, depending on the nanoribbon width. In this study, we investigate the electronic structure changes during the formation of GNRs, nitrogen-doped (singly and doubly N-doped) as well as non-N-doped chevron-shaped CGNRs on Au(111). Thus we determine the optical gaps of the precursor molecules, the intermediate nonaromatic polymers, and finally the aromatic GNRs, using high-resolution electron energy loss spectroscopy and density functional theory calculations. As expected, we find no influence of N-doping on the size of the optical gaps. The gap of the precursor molecules is around 4.5 eV. Polymerization leads to a reduction of the gap to a value of 3.2 eV due to elongation and thus enhanced delocalization. The CGNRs exhibit a band gap of 2.8 eV, thus the gap is further reduced in the nanoribbons, since they exhibit an extended delocalized π -electron system.
Fracture mechanics analysis of the dentine-luting cement interface.
Ryan, A K; Mitchell, C A; Orr, J F
2002-01-01
The objectives of this study were to determine the fracture toughness of adhesive interfaces between dentine and clinically relevant, thin layers of dental luting cements. Cements tested included a conventional glass-ionomer, F (Fuji 1), a resin-modified glass-ionomer, FP (Fuji Plus) and a compomer cement, D (DyractCem). Ten miniature short-bar chevron notch specimens were manufactured for each cement, each comprising a 40 microm thick chevron of lute, between two 1.5 mm thick blocks of bovine dentine, encased in resin composite. The interfacial K(IC) results (MN/m3/2) were median (range): F; 0.152 (0.14-0.16), FP; 0.306 (0.27-0.37), D; 0.351 (0.31-0.37). Non-parametric statistical analysis showed that the fracture toughness of F was significantly lower (p <0.05) than those of FP or D, and all were significantly lower than values for monolithic cement specimens. Scanning electron microscopy of the specimens suggested crack propagation along the interface. However, energy dispersive X-ray analysis indicated that failure was cohesive within the cement. It is concluded that the fracture toughness of luting cement was lowered by cement-dentine interactions.
NASA Astrophysics Data System (ADS)
van Straaten, O.; Veldkamp, E.; Köhler, M.; Anas, I.
2010-04-01
Climate change induced droughts pose a serious threat to ecosystems across the tropics and sub-tropics, particularly to those areas not adapted to natural dry periods. In order to study the vulnerability of cacao (Theobroma cacao) - Gliricidia sepium agroforestry plantations to droughts a large scale throughfall displacement roof was built in Central Sulawesi, Indonesia. In this 19-month experiment, we compared soil surface CO2 efflux (soil respiration) from three roof plots with three adjacent control plots. Soil respiration rates peaked at intermediate soil moisture conditions and decreased under increasingly dry conditions (drought induced), or increasingly wet conditions (as evidenced in control plots). The roof plots exhibited a slight decrease in soil respiration compared to the control plots (average 13% decrease). The strength of the drought effect was spatially variable - while some measurement chamber sites reacted strongly (responsive) to the decrease in soil water content (up to R2=0.70) (n=11), others did not react at all (non-responsive) (n=7). A significant correlation was measured between responsive soil respiration chamber sites and sap flux density ratios of cacao (R=0.61) and Gliricidia (R=0.65). Leaf litter CO2 respiration decreased as conditions became drier. The litter layer contributed approximately 3-4% of the total CO2 efflux during dry periods and up to 40% during wet periods. Within days of roof opening soil CO2 efflux rose to control plot levels. Thereafter, CO2 efflux remained comparable between roof and control plots. The cumulative effect on soil CO2 emissions over the duration of the experiment was not significantly different: the control plots respired 11.1±0.5 Mg C ha-1 yr-1, while roof plots respired 10.5±0.5 Mg C ha-1 yr-1. The relatively mild decrease measured in soil CO2 efflux indicates that this agroforestry ecosystem is capable of mitigating droughts with only minor stress symptoms.
Avoiding treatment bias of REDD+ monitoring by sampling with partial replacement.
Köhl, Michael; Scott, Charles T; Lister, Andrew J; Demon, Inez; Plugge, Daniel
2015-12-01
Implementing REDD+ renders the development of a measurement, reporting and verification (MRV) system necessary to monitor carbon stock changes. MRV systems generally apply a combination of remote sensing techniques and in-situ field assessments. In-situ assessments can be based on 1) permanent plots, which are assessed on all successive occasions, 2) temporary plots, which are assessed only once, and 3) a combination of both. The current study focuses on in-situ assessments and addresses the effect of treatment bias, which is introduced by managing permanent sampling plots differently than the surrounding forests. Temporary plots are not subject to treatment bias, but are associated with large sampling errors and low cost-efficiency. Sampling with partial replacement (SPR) utilizes both permanent and temporary plots. We apply a scenario analysis with different intensities of deforestation and forest degradation to show that SPR combines cost-efficiency with the handling of treatment bias. Without treatment bias permanent plots generally provide lower sampling errors for change estimates than SPR and temporary plots, but do not provide reliable estimates, if treatment bias occurs, SPR allows for change estimates that are comparable to those provided by permanent plots, offers the flexibility to adjust sample sizes in the course of time, and allows to compare data on permanent versus temporary plots for detecting treatment bias. Equivalence of biomass or carbon stock estimates between permanent and temporary plots serves as an indication for the absence of treatment bias while differences suggest that there is evidence for treatment bias. SPR is a flexible tool for estimating emission factors from successive measurements. It does not entirely depend on sample plots that are installed at the first occasion but allows for the adjustment of sample sizes and placement of new plots at any occasion. This ensures that in-situ samples provide representative estimates over time. SPR offers the possibility to increase sampling intensity in areas with high degradation intensities or to establish new plots in areas where permanent plots are lost due to deforestation. SPR is also an ideal approach to mitigate concerns about treatment bias.
Biological tissue imaging with a position and time sensitive pixelated detector.
Jungmann, Julia H; Smith, Donald F; MacAleese, Luke; Klinkert, Ivo; Visser, Jan; Heeren, Ron M A
2012-10-01
We demonstrate the capabilities of a highly parallel, active pixel detector for large-area, mass spectrometric imaging of biological tissue sections. A bare Timepix assembly (512 × 512 pixels) is combined with chevron microchannel plates on an ion microscope matrix-assisted laser desorption time-of-flight mass spectrometer (MALDI TOF-MS). The detector assembly registers position- and time-resolved images of multiple m/z species in every measurement frame. We prove the applicability of the detection system to biomolecular mass spectrometry imaging on biologically relevant samples by mass-resolved images from Timepix measurements of a peptide-grid benchmark sample and mouse testis tissue slices. Mass-spectral and localization information of analytes at physiologic concentrations are measured in MALDI-TOF-MS imaging experiments. We show a high spatial resolution (pixel size down to 740 × 740 nm(2) on the sample surface) and a spatial resolving power of 6 μm with a microscope mode laser field of view of 100-335 μm. Automated, large-area imaging is demonstrated and the Timepix' potential for fast, large-area image acquisition is highlighted.
Forest disturbance spurs growth of modeling and technology
NASA Astrophysics Data System (ADS)
Bohrer, G.; Matheny, A. M.; Mirfenderesgi, G.; Morin, T. H.; Rey Sanchez, A. C.; Gough, C. M.; Vogel, C. S.; Nadelhoffer, K. J.; Curtis, P.
2016-12-01
As new opportunities for scientific exploration open, needs for data generate a drive for innovative developments of new research tools. The Forest Accelerated Succession ExperimenT (FASET) was enacted in 2007, continuous flux observations at the University of Michigan Biological Station (UMBS) since 2000. FASET is a large-scale ecological experiment testing the immediate and intermediate term effects of disturbance, and eventually, the role of succession and community composition on forest flux dynamics. Decades-long tree-level observations in the UMBS forest, combined with the long term flux observations allowed us to match the bottom-up accumulated response of individual trees with the top-down whole-plot response measured from the flux tower. However, data describing tree-level canopy structure and hydrological response over an entire plot were not readily available. Unintentionally, FASET became both a motivation and a test-bed for new research tools and approaches. We expanded the operation and analysis approach for a portable canopy LiDARfor 3-D measurements meter-scale canopy structure. We matched canopy LiDAR measurements with root measurements from ground penetrating radar. To study the hydrological effects of the disturbance, we instrumented a large number of trees with Granier-style sap flux sensors. We further developed an approach to use frequency domain reflectometry sensors for continuous measurements of tree water content. We developed an approach to combine plot census, allometry and sap-flux observations in a bottom-up fashion to compare with plot-level EC transpiration rates. We found that while the transpirational water demand in the disturbance plot increased, overall evapotranspiration decreased. This decrease, however, is not uniform across species. A new individual-plant to ecosystem scale hydrodynamic model (FETCH2) demonstrates how specific traits translate to intra-daily differences in plot-level transpiration dynamics.