Anderson, Collin; MacKay, Mark
2016-11-01
Calcium and phosphate precipitation is an ongoing concern when compounding pediatric parenteral nutrition (PN) solutions. Considerable effort has been expended in producing graphs, tables, and equations to guide the practitioner in prescribing PN that will remain stable. Calcium gluconate is preferred over calcium chloride when compounding PN because of its superior compatibility with inorganic phosphates. PN solutions containing calcium gluconate carry a higher aluminum load than equivalent solutions compounded with calcium chloride, leading to increased potential for aluminum toxicity. This study tested the solubility of calcium chloride in PN solutions compounded with an organic phosphate component, sodium glycerophosphate (NaGP), in place of sodium phosphate. Five PN solutions were compounded by adding calcium chloride at 10, 20, 30, 40, and 50 mEq/L and corresponding concentrations of NaGP at 10, 20, 30, 40, and 50 mmol/L. Each of the 5 solutions was compounded using 1.5% and 4% amino acids, cysteine, and lipids. The physical stability was evaluated by visual inspection (precipitation, haze, and color change). Solutions were evaluated microscopically for any microcrystals using U.S. Pharmacopeia <788> standards. Compatibility testing showed no changes in the PN solution in any of the concentrations tested. Calcium chloride was found to be physically compatible with NaGP in PN at the tested concentrations. Utilization of NaGP in PN solutions would eliminate the need for precipitation curves and allow for the use of calcium chloride. Compounding with NaGP and calcium chloride allows the practitioner a mechanism for reducing the aluminum load in PN. © 2015 American Society for Parenteral and Enteral Nutrition.
Electrochemical Test Method for Evaluating Long-Term Propellant-Material Compatibility
1978-12-01
matrix of test conditions is illustrated in Fig. 13. A statistically designed test matrix (Graeco-Latin Cube) could not be used because of passivation...ears simulated time results in a findl decomposition level of 0.753 mg/cm The data was examined using statistical techniqves to evaluate the relative...metals. The compatibility of all nine metals was evaluated in hydrazine containing water and chloride. The results of the statistical analy(is
Physical compatibility of plazomicin with select i.v. drugs during simulated Y-site administration.
Asempa, Tomefa E; Avery, Lindsay M; Kidd, James M; Kuti, Joseph L; Nicolau, David P
2018-06-12
The results of a study to determine the physical compatibility of plazomicin sulfate solution during simulated Y-site administration with 92 i.v. drugs are reported. Plazomicin injection solution (500 mg/10 mL) was diluted in 0.9% sodium chloride or 5% dextrose for injection to a final volume of 50 mL (final plazomicin concentration, 24 mg/mL), consistent with a 15-mg/kg dose administered to an 80-kg patient (i.e., 1,200 mg). All other i.v. drugs were reconstituted according to manufacturers' recommendations and diluted with 0.9% sodium chloride or 5% dextrose for injection to the upper range of concentrations used clinically. Y-site conditions were simulated by mixing 5 mL of plazomicin solution with 5 mL of tested drug solutions in a 1:1 ratio. Solutions were assessed for visual (via color and Tyndall beam testing), turbidity (using a laboratory-grade turbidimeter), and pH changes over a 60-minute observation period. Incompatibility was defined a priori as precipitation, color change, a positive Tyndall test, or a turbidity change of ≥0.5 nephelometric turbidity units at any time during the 60-minute observation period. Plazomicin was physically compatible with 79 of the 92 drugs tested. Determinations of physical incompatibility with plazomicin were made for 13 drugs: albumin, amiodarone, amphotericin B deoxycholate, anidulafungin, calcium chloride, daptomycin, esomeprazole, heparin, levofloxacin, methylprednisolone, micafungin, phenytoin, and propofol, CONCLUSION: Plazomicin at a concentration of 24 mg/mL was physically compatible with 85% of the drugs tested, including 31 of 36 antimicrobial agents. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Jacob, Rhys; Trout, Neil; Raud, Ralf; Clarke, Stephen; Steinberg, Theodore A.; Saman, Wasim; Bruno, Frank
2016-05-01
In an effort to reduce the cost and increase the material compatibility of encapsulated phase change materials (EPCMs) a new encapsulated system has been proposed. In the current study a molten salt eutectic of barium chloride (53% wt.), potassium chloride (28% wt.) and sodium chloride (19% wt.) has been identified as a promising candidate for low cost EPCM storage systems. The latent heat, melting point and thermal stability of the phase change material (PCM) was determined by DSC and was found to be in good agreement with results published in the literature. To cope with the corrosive nature of the PCM, it was decided that a fly-ash based geopolymer met the thermal and economic constraints for encapsulation. The thermal stability of the geopolymer shell was also tested with several formulations proving to form a stable shell for the chosen PCM at 200°C and/or 600°C. Lastly several capsules of the geopolymer shell with a chloride PCM were fabricated using a variety of methods with several samples remaining stable after exposure to 600°C testing.
Nahata, M C; Morosco, R S; Sabados, B K; Weber, T R
1997-06-01
The stability and compatibility of anakinra (recombinant human interleukin-1 receptor antagonist) with ceftriaxone sodium in 0.9% sodium chloride or 5% dextrose injection was determined during a 4-h period at ambient room temperature and light. Anakinra was diluted in 0.9% sodium chloride or 5% dextrose to the concentrations of 4 and 36 mg/ml. Anakinra, at each concentration was mixed with ceftriaxone sodium (20 mg/ml) in a 50:50 proportion and stored in plastic culture vials with polypropylene caps. The samples were collected at 0, 2 and 4 h after mixing. Anakinra and ceftriaxone concentrations were measured using stability-indicating HPLC methods. In 0.9% sodium chloride injection, the mean concentrations of anakinra and ceftriaxone exceeded 98% of initial concentrations at the end of the study period. In 5% dextrose, however, anakinra concentrations were below 90% of the expected initial concentration at the time of first analysis (within 0.5 h). Thus, anakinra appears to be stable and compatible with ceftriaxone sodium when diluted in 0.9% sodium chloride injection, but not in 5% dextrose injection over 4 h at ambient room temperature and light.
Compatibility of butorphanol and droperidol in 0.9% sodium chloride injection.
Chen, Fu-Chao; Fang, Bao-Xia; Li, Peng; Yang, Jin-Guo; Zhou, Ben-Hong
2013-03-15
The compatibility and stability of butorphanol tartrate and droperidol in polyvinyl chloride (PVC) bags and glass bottles stored at 4°C and 25°C for up to 15 days were studied. Admixtures were assessed initially and for 15 days after preparation in PVC bags and glass bottles using 0.9% sodium chloride injection as a diluent and stored at 4°C and 25°C. The initial drug concentrations were 0.08 mg/mL for butorphanol tartrate and 0.05 mg/mL for droperidol. Samples were withdrawn from each container immediately after preparation and at predetermined intervals (2, 4, 8, 24, 48, 72, 120, 168, 240, and 360 hours after preparation). The solutions were visually inspected for precipitation, cloudiness, and discoloration at each sampling interval. Drug concentrations were determined using a validated high-pressure liquid chromatography method. After 15 days of storage, all formulations tested retained >98% of the initial concentrations of both drugs. The drug mixtures were clear in appearance, and no color change or precipitation was observed. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and droperidol 0.05 mg/mL in 0.9% sodium chloride injection were stable for at least 360 hours when stored in PVC bags or glass bottles at 4°C and 25°C and protected from light.
Huston, Robert K; Christensen, J Mark; Alshahrani, Sultan M; Mohamed, Sumeia M; Clark, Sara M; Nason, Jeffrey A; Wu, Ying Xing
2015-01-01
Previous studies of compatibility of calcium chloride (CaCl2) and phosphates have not included particle counts in the range specified by the United States Pharmacopeia. Micro-flow imaging techniques have been shown to be comparable to light obscuration when determining particle count and size in pharmaceutical solutions. The purpose of this study was to do compatibility testing for parenteral nutrition (PN) solutions containing CaCl2 using dynamic light scattering and micro-flow imaging techniques. Solutions containing TrophAmine (Braun Medical Inc, Irvine, CA), CaCl2, and sodium phosphate (NaPhos) were compounded with and without cysteine. All solutions contained standard additives to neonatal PN solutions including dextrose, trace metals, and electrolytes. Control solutions contained no calcium or phosphate. Solutions were analyzed for particle size and particle count. Means of Z-average particle size and particle counts of controls were determined. Study solutions were compared to controls and United States Pharmacopeia (USP) Chapter 788 guidelines. The maximum amount of Phos that was compatible in solutions that contained at least 10 mmol/L of Ca in 2.5% amino acids (AA) was determined. Compatibility of these solutions was verified by performing analyses of 5 repeats of these solutions. Microscopic analyses of the repeats were also performed. Amounts of CaCl2 and NaPhos that were compatible in solutions containing 1.5%, 2%, 2.5%, and 3% AA were determined. The maximum amount of NaPhos that could be added to TrophAmine solutions of > = 2.5% AA containing at least 10 mmol/L of CaCl2 was 7.5 mmol/L. Adding 50 mg/dL of cysteine increased the amount of NaPhos that could be added to solutions containing 10 mmol/L of CaCl2 to 10 mmol/L. Calcium chloride can be added to neonatal PN solutions containing NaPhos in concentrations that can potentially provide an intravenous intake of adequate amounts of calcium and phosphorus.
Shiyan, Anna; Thompson, Melanie; Köcher, Saskia; Tausendschön, Michaela; Santos, Helena; Hänelt, Inga; Müller, Volker
2014-01-01
Halobacillus halophilus, a moderately halophilic bacterium isolated from salt marshes, produces various compatible solutes to cope with osmotic stress. Glutamate and glutamine are dominant compatible solutes at mild salinities. Glutamine synthetase activity in cell suspensions of Halobacillus halophilus wild type was shown to be salt dependent and chloride modulated. A possible candidate to catalyze glutamine synthesis is glutamine synthetase A2, whose transcription is stimulated by chloride. To address the role of GlnA2 in the biosynthesis of the osmolytes glutamate and glutamine, a deletion mutant (ΔglnA2) was generated and characterized in detail. We compared the pool of compatible solutes and performed transcriptional analyses of the principal genes controlling the solute production in the wild type strain and the deletion mutant. These measurements did not confirm the hypothesized role of GlnA2 in the osmolyte production. Most likely the presence of another, yet to be identified enzyme has the main contribution in the measured activity in crude extracts and probably determines the total chloride-modulated profile. The role of GlnA2 remains to be elucidated. PMID:24782854
Chemical and physical compatibility of an intravenous solution of epinephrine with calcium chloride.
Weeks, Phillip A; Teng, Yang; Wu, Lei; Sun, Mary; Yang, Zhen; Chow, Diana S-L
2014-01-01
An infusion of epinephrine combined with calcium chloride has been used historically as an intravenous inotropic solution to support critically ill heart failure patients with severe cardiogenic shock. There is no reliable data on the stability of this solution beyond three hours. This study was conducted to evaluate the chemical and physical compatibility of epinephrine (0.032 mg/mL) combined with calcium chloride (4 mg/mL) in a solution for intravenous administration up to 26 hours at room temperature. The chemical stability of epinephrine was monitored by measuring epinephrine concentrations using high-performance liquid chromatography. The physical compatibility of the mixture was determined by measuring spectrophotometric absorbance between 400 to 700 nm. Absorbance greater than 0.010 AU was considered an indicator of the presence of precipitation. The results showed epinephrine with calcium chloride was stable together in normal saline up to 26 hours at room temperature, irrespective of exposure to light. The absorbance of epinephrine throughout the study was less than 0.010 AU, indicating no significant precipitation. Conclusions indicate that epinephrine (0.032 mg/mL) combined with calcium chloride (4 mg/mL) in normal saline at room temperature is acceptably stable up to 26 hours for intravenous administration.
COMPATIBILITY OF BENTONITE AND DNAPLS
The compatibility of dense non-aqueous phase liquids (DNAPLs), trichloroethylene (TCE), methylene chloride (MC), and creosote with commercially available sodium bentonite pellets was evaluated using stainless steel, double-ring, falling-head permeameters. The Hydraulic conductiv...
Faria, Alethéa Guimarães; Marson, Fernando Augusto Lima; Gomez, Carla Cristina de Souza; Ribeiro, Maria Ângela Gonçalves de Oliveira; Morais, Lucas Brioschi; Servidoni, Maria de Fátima; Bertuzzo, Carmen Sílvia; Sakano, Eulália; Goto, Maura; Paschoal, Ilma Aparecida; Pereira, Mônica Corso; Hessel, Gabriel; Levy, Carlos Emílio; Toro, Adyléia Aparecida Dalbo Contrera; Peixoto, Andressa Oliveira; Simões, Maria Cristina Ribeiro; Lomazi, Elizete Aparecida; Nogueira, Roberto José Negrão; Ribeiro, Antônio Fernando; Ribeiro, José Dirceu
2016-10-26
To assess the quality of sweat test (ST) based on the proportion of sweat sodium and sweat chloride as diagnostic parameter of cystic fibrosis (CF). A retrospective study of 5,721 sweat samples and subsequent descriptive analysis were carried out. The test was considered "of good quality" (correct) when: (i) sweat chloride was lower than 60 mEq/L, and sweat sodium was higher than sweat chloride; (ii) sweat chloride was higher than 60 mEq/L, and sweat sodium was lower than sweat chloride. The study included 5,692/5,721 sweat samples of ST which had been requested due to clinical presentations compatible with CF and/or neonatal screenings with altered immunoreactive trypsinogen values. Considering the proportion of sweat sodium and sweat chloride as ST quality parameter, the test was performed correctly in 5,023/5,692 (88.2 %) sweat samples. The sweat chloride test results were grouped into four reference ranges for chloride (i) chloride < 30 mEq/L: 3,651/5,692 (64.1 %); (ii) chloride ≥ 30 mEq/L to < 40 mEq/L: 652/5,692 (11.5 %); (iii) ≥ 40 mEq/L to < 60 mEq/L: 673/5,692 (11.8 %); (iv) ≥ 60 mEq/L: 716/5,692 (12.6 %). In the comparative analysis, there was no association between ST quality and: (i) symptoms to indicate a ST [respiratory (p = 0.084), digestive (p = 0.753), nutritional (p = 0.824), and others (p = 0.136)], (ii) sweat weight (p = 0.416). However, there was a positive association with: (i) gender, (ii) results of ST (p < 0.001), (iii) chloride/sodium ratio (p < 0.001), (iv) subject's age at the time of ST [grouped according to category (p < 0.001) and numerical order (p < 0.001)]. For the subset of 169 patients with CF and two CFTR mutations Class I, II and/or III, in comparative analysis, there was a positive association with: (i) sweat chloride/sodium ratio (p < 0.001), (ii) sweat chloride values (p = 0.047), (iii) subject's age at the time of the ST grouped by numerical order (p = 0.001). Considering that the quality of ST can be assessed by levels of sweat sodium and sweat chloride, an increasing number of low-quality tests could be observed in our sweat samples. The quality of the test was associated with important factors, such as gender, CF diagnosis, and subjects' age.
Hänelt, Inga; Müller, Volker
2013-01-01
The capability of osmoadaptation is a prerequisite of organisms that live in an environment with changing salinities. Halobacillus halophilus is a moderately halophilic bacterium that grows between 0.4 and 3 M NaCl by accumulating both chloride and compatible solutes as osmolytes. Chloride is absolutely essential for growth and, moreover, was shown to modulate gene expression and activity of enzymes involved in osmoadaptation. The synthesis of different compatible solutes is strictly salinity- and growth phase-dependent. This unique hybrid strategy of H. halophilus will be reviewed here taking into account the recently published genome sequence. Based on identified genes we will speculate about possible scenarios of the synthesis of compatible solutes and the uptake of potassium ion which would complete our knowledge of the fine-tuned osmoregulation and intracellular osmolyte balance in H. halophilus. PMID:25371341
Sun, Lili; Ding, Feifei; You, Guangjiao; Liu, Han; Wang, Meng; Ren, Xiaoliang; Deng, Yanru
2017-01-01
JinQi Jiangtang (JQJT) tablets, a Chinese patent medicine approved by the State Food and Drug Administration, are composed of Coptidis Rhizoma, Astragali Radix, and Lonicerae Japonicae Flos, and have a significant effect on diabetes. Coptidis Rhizoma is monarch drug in the prescription. The aim of the present study was to investigate and compare the pharmacokinetics of multiple ingredients from JQJT tablets and Coptidis Rhizoma extract (CRE) following oral administration in rats. Five alkaloids: coptisine chloride, epiberberine chloride, berberine chloride, jatrorrhizine chloride, and palmatine chloride, were simultaneously determined in rat plasma using established and validated ultra-high performance liquid chromatography mass spectrometry (UPLC-MS/MS). Significant pharmacokinetic differences were observed for the five alkaloids after a single administration of CRE and JQJT tablets. Compared with CRE, the Cmax values of palmatine chloride and jatrorrhizine chloride were decreased significantly, the AUC0–t values of four alkaloids (all except jatrorrhizine chloride) were notably decreased, and the mean residence times of all five alkaloids were significantly decreased after administration of JQJT tablets. The results indicated that the absorption characteristics of the five alkaloids from Coptidis Rhizoma would be influenced by the compatibility of Astragali Radix or Lonicerae Japonicae Flos from JQJT tablets, such that absorption was inhibited and elimination was accelerated. In conclusion, the developed strategy was suitable for the comparison of five alkaloids from JinQi Jiangtang tablets and its monarch drug, which could be valuable for compatibility studies of traditional Chinese medicines. PMID:29286316
Saum, Stephan H; Pfeiffer, Friedhelm; Palm, Peter; Rampp, Markus; Schuster, Stephan C; Müller, Volker; Oesterhelt, Dieter
2013-05-01
Salt acclimation in moderately halophilic bacteria is the result of action of a grand interplay orchestrated by signals perceived from the environment. To elucidate the cellular players involved in sensing and responding to changing salinities we have determined the genome sequence of Halobacillus halophilus, a Gram-positive moderate halophilic bacterium that has a strict requirement for the anion chloride. Halobacillus halophilus synthesizes a multitude of different compatible solutes and switches its osmolyte strategy with the external salinity and growth phase. Based on the emerging genome sequence, the compatible solutes glutamate, glutamine, proline and ectoine have already been experimentally studied. The biosynthetic routes for acetyl ornithine and acetyl lysine are also delineated from the genome sequence. Halobacillus halophilus is nutritionally very versatile and most compatible solutes cannot only be produced but also used as carbon and energy sources. The genome sequence unravelled isogenes for many pathways indicating a fine regulation of metabolism. Halobacillus halophilus is unique in integrating the concept of compatible solutes with the second fundamental principle to cope with salt stress, the accumulation of molar concentrations of salt (Cl(-)) in the cytoplasm. Extremely halophilic bacteria/archaea, which exclusively rely on the salt-in strategy, have a high percentage of acidic proteins compared with non-halophiles with a low percentage. Halobacillus halophilus has an intermediate position which is consistent with its ability to integrate both principles. © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.
Visual compatibility of defibrotide with selected drugs during simulated Y-site administration.
Correard, Florian; Savry, Amandine; Gauthier-Villano, Laurence; Pisano, Pascale; Pourroy, Bertrand
2014-08-01
The visual compatibility of a solution of defibrotide (the only drug recommended for treatment and prophylaxis of hepatic venoocclusive disease) with solutions of various drugs commonly administered in bone marrow transplant procedures was studied. Solutions of 43 drug products in concentrations typically used in clinical practice were evaluated in 1:1 mixtures with defibrotide solution in glass tubes kept at room temperature. The evaluated products included antiinfectious, corticoid, sedative, analgesic, and cardiovascular agents widely used for hematopoietic stem cell transplantation and other marrow transplant procedures; in most cases, test solutions were prepared via dilution in or reconstitution with sterile water, 0.9% sodium chloride injection, or 5% dextrose injection. The mixtures were visually observed immediately after manual mixing and at specified time points (60, 150, and 240 minutes). Visual compatibility was defined as the absence of color change, haze, fibers, particles, gas generation, and precipitate formation. The effect of mixing order on visual compatibility was ascertained. Of the 43 tested drug solutions, 36 were found to be visually compatible with the defibrotide solution over the entire four-hour study period. Solutions of 7 drugs (amikacin, furosemide, midazolam, mycophenolate mofetil, nicardipine, tobramycin, and vancomycin) were visually incompatible with defibrotide solution. In some cases, evidence of incompatibility was observed intermittently or was dependent on mixing order. Defibrotide solution was found to be visually compatible with solutions of 36 i.v. products that are likely to be coadministered with the drug in a bone marrow transplant unit. Seven drug solutions were visually incompatible with defibrotide solution. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
The Corrosion of Metals in Aqueous Film-Forming Foams.
CORROSION), (*FIRE EXTINGUISHERS, STAINLESS STEEL), (*STAINLESS STEEL, (* FOAM , CORROSION), PH FACTOR, CHLORIDES, FLUORIDES, STEEL, NICKEL ALLOYS, COPPER ALLOYS, NAVAL EQUIPMENT, AIRCRAFT CARRIERS, SEA WATER, COMPATIBILITY.
Ionic liquids as refolding additives: N′-alkyl and N′-(ω-hydroxyalkyl) N-methylimidazolium chlorides
Lange, Christian; Patil, Ganesh; Rudolph, Rainer
2005-01-01
The purpose of this work was to investigate the influence of a series of N′-alkyl and N′-(ω-hydroxy-alkyl)-N-methylimidazolium chlorides on the renaturation of two model proteins, namely hen egg white lysozyme and the single-chain antibody fragment ScFvOx. All tested ionic liquids acted as refolding enhancers, with varying efficacies and efficiencies. The results of the refolding screening could be interpreted by taking into account the effect of the studied ionic liquids on protein aggregation, together with the systematic variations of their influence on the stability of native proteins in solution. More hydrophobic imidazolium cations carrying longer alkyl chains were increasingly destabilizing, while terminal hydroxylation of the alkyl chain made the salts more compatible with protein stability. The studied ionic liquids can be classified as preferentially bound, slightly to moderately chaotropic cosolvents for proteins. PMID:16195554
Cabrera, J; Mancuso, M; Cabrera-Fránquiz, F; Limiñana, J; Díez, A
2011-01-01
To determine whether a mixture for intravenous perfusion containing tramadol (5 mg/ml), ranitidine (1.5 mg/ml), ketorolac (1.5 mg/ml) and metoclopramide (0.5 mg/ml) in a 0.9% sodium chlorides solution is compatible and stable at room temperature during a 48-hour period. We tested the mixture for stability using the HPLC technique (high performance liquid chromatography), with parallel visual assessments of any changes in colour, appearance of precipitate or phase separation indicating incompatibilities between the components. At the end of the trial, chromatography data showed a mean metoclopramide concentration between 100% and 105% of the initial level, while concentrations of tramadol, ketorolac and ranitidine were between 99% and 102% of initial levels. There was no evidence of incompatibility between the drugs at any time during the study period. The combination is stable as a solution and its components are physically and chemically compatible in the concentrations used in the study, during at least 48 hours at room temperature. Copyright © 2008 SEFH. Published by Elsevier Espana. All rights reserved.
Multiple Osmotic Stress Responses in Acidihalobacter prosperus Result in Tolerance to Chloride Ions.
Dopson, Mark; Holmes, David S; Lazcano, Marcelo; McCredden, Timothy J; Bryan, Christopher G; Mulroney, Kieran T; Steuart, Robert; Jackaman, Connie; Watkin, Elizabeth L J
2016-01-01
Extremely acidophilic microorganisms (pH optima for growth of ≤3) are utilized for the extraction of metals from sulfide minerals in the industrial biotechnology of "biomining." A long term goal for biomining has been development of microbial consortia able to withstand increased chloride concentrations for use in regions where freshwater is scarce. However, when challenged by elevated salt, acidophiles experience both osmotic stress and an acidification of the cytoplasm due to a collapse of the inside positive membrane potential, leading to an influx of protons. In this study, we tested the ability of the halotolerant acidophile Acidihalobacter prosperus to grow and catalyze sulfide mineral dissolution in elevated concentrations of salt and identified chloride tolerance mechanisms in Ac. prosperus as well as the chloride susceptible species, Acidithiobacillus ferrooxidans . Ac. prosperus had optimum iron oxidation at 20 g L -1 NaCl while At. ferrooxidans iron oxidation was inhibited in the presence of 6 g L -1 NaCl. The tolerance to chloride in Ac. prosperus was consistent with electron microscopy, determination of cell viability, and bioleaching capability. The Ac. prosperus proteomic response to elevated chloride concentrations included the production of osmotic stress regulators that potentially induced production of the compatible solute, ectoine uptake protein, and increased iron oxidation resulting in heightened electron flow to drive proton export by the F 0 F 1 ATPase. In contrast, At. ferrooxidans responded to low levels of Cl - with a generalized stress response, decreased iron oxidation, and an increase in central carbon metabolism. One potential adaptation to high chloride in the Ac. prosperus Rus protein involved in ferrous iron oxidation was an increase in the negativity of the surface potential of Rus Form I (and Form II) that could help explain how it can be active under elevated chloride concentrations. These data have been used to create a model of chloride tolerance in the salt tolerant and susceptible species Ac. prosperus and At. ferrooxidans , respectively.
Multiple Osmotic Stress Responses in Acidihalobacter prosperus Result in Tolerance to Chloride Ions
Dopson, Mark; Holmes, David S.; Lazcano, Marcelo; McCredden, Timothy J.; Bryan, Christopher G.; Mulroney, Kieran T.; Steuart, Robert; Jackaman, Connie; Watkin, Elizabeth L. J.
2017-01-01
Extremely acidophilic microorganisms (pH optima for growth of ≤3) are utilized for the extraction of metals from sulfide minerals in the industrial biotechnology of “biomining.” A long term goal for biomining has been development of microbial consortia able to withstand increased chloride concentrations for use in regions where freshwater is scarce. However, when challenged by elevated salt, acidophiles experience both osmotic stress and an acidification of the cytoplasm due to a collapse of the inside positive membrane potential, leading to an influx of protons. In this study, we tested the ability of the halotolerant acidophile Acidihalobacter prosperus to grow and catalyze sulfide mineral dissolution in elevated concentrations of salt and identified chloride tolerance mechanisms in Ac. prosperus as well as the chloride susceptible species, Acidithiobacillus ferrooxidans. Ac. prosperus had optimum iron oxidation at 20 g L−1 NaCl while At. ferrooxidans iron oxidation was inhibited in the presence of 6 g L−1 NaCl. The tolerance to chloride in Ac. prosperus was consistent with electron microscopy, determination of cell viability, and bioleaching capability. The Ac. prosperus proteomic response to elevated chloride concentrations included the production of osmotic stress regulators that potentially induced production of the compatible solute, ectoine uptake protein, and increased iron oxidation resulting in heightened electron flow to drive proton export by the F0F1 ATPase. In contrast, At. ferrooxidans responded to low levels of Cl− with a generalized stress response, decreased iron oxidation, and an increase in central carbon metabolism. One potential adaptation to high chloride in the Ac. prosperus Rus protein involved in ferrous iron oxidation was an increase in the negativity of the surface potential of Rus Form I (and Form II) that could help explain how it can be active under elevated chloride concentrations. These data have been used to create a model of chloride tolerance in the salt tolerant and susceptible species Ac. prosperus and At. ferrooxidans, respectively. PMID:28111571
Design Guide: Designing and Building High Voltage Power Supplies. Volume 2
1988-08-01
and edges. * Isolation system: * One layer ol’ Tedlar: or type 120 glass fabric with a compatible resin : or finish. 199 5.4.2 Composite Joints...plastics Cellulose esters Asphalt Cork Chloride flux Epoxy resins Copper (bare) Masonite Fiber board Melamine resins Greases Nylon Polyvinyl chloride resins ...cycloaliphatic epoxy to a level inferior to the porcelain. In one application having a glass -cloth epoxy- based laminate coated with cycloaliphatic epoxy the
The Pd-Catalyzed Conversion of Aryl Chlorides, Triflates, and Nonaflates to Nitroaromatics
Fors, Brett P.; Buchwald, Stephen L.
2009-01-01
An efficient Pd-catalyst for the transformation of aryl chlorides, triflates and nonaflates to nitroaromatics has been developed. This reaction proceeds under weekly basic conditions and displays a broad scope and excellent functional group compatibility. Moreover, this method allows for the synthesis of aromatic nitro compounds that cannot be accessed efficiently via other nitration protocols. Mechanistic insight into the trasmetallation step of the catalytic process is also reported. PMID:19737014
Hammond, Naomi E; Bellomo, Rinaldo; Gallagher, Martin; Gattas, David; Glass, Parisa; Mackle, Diane; Micallef, Sharon; Myburgh, John; Saxena, Manoj; Taylor, Colman; Young, Paul; Finfer, Simon
2017-09-01
0.9% sodium chloride (saline) is the most commonly administered resuscitation fluid on a global basis but emerging evidence suggests that its high chloride content may have important adverse effects. To describe the study protocol for the Plasma- Lyte 148 v Saline study, which will test the hypothesis that in critically ill adult patients the use of Plasma-Lyte 148 (a buffered crystalloid solution) for fluid therapy results in different 90-day all-cause mortality when compared with saline. We will conduct this multicentre, blinded, randomised controlled trial in approximately 50 intensive care units in Australia and New Zealand. We will randomly assign 8800 patients to either Plasma-Lyte 148 or saline for all resuscitation fluid, maintenance fluid and compatible drug dilution therapy while in the ICU for up to 90 days after randomisation. The primary outcome is 90-day all-cause mortality; secondary outcomes include mean and peak creatinine concentration, incidence of renal replacement therapy, incidence and duration of vasoactive drug treatment, duration of mechanical ventilation, ICU and hospital length of stay, and quality of life and health services use at 6 months. The PLUS study will provide high-quality data on the comparative safety and efficacy of Plasma-Lyte 148 compared with saline for resuscitation and compatible crystalloid fluid therapy in critically ill adult patients.
NASA Astrophysics Data System (ADS)
Wu, Yuda; Zhao, Gang; Wei, Chengye; Liu, Shuang; Fu, Yu; Liu, Xvxiong
2018-01-01
As a kind of artificial muscle intelligent material, the biological gel electric driver has the advantages of low driving voltage, large strain, good biological compatibility, good flexibility, low price, etc. The application prospect is broad and it has high academic value. Alginate, as a common substance in sea, has characteristics of low cost, green and pollution-free. Therefore,this paper obtains biological gel electric actuator by sodium alginate and calcium chloride. Effects on output force of the electric actuator is researched by changing the crosslinking of calcium chloride concentration and the output force enhancement mechanism is analyzed in this paper.
Transition-Metal-Free Alkynylation of Aryl Chlorides
Truong, Thanh; Daugulis, Olafs
2011-01-01
Two sets of conditions have been developed for a base-mediated, transition-metal-free alkynylation of aryl chlorides that proceeds via benzyne intermediates. The first set of conditions involves the use of TMPLi base in a pentane/THF mixture at 25 °C. The second set involves use of a metal alkoxide base in dioxane at elevated temperature. Reasonable functional group tolerance has been observed. Fluoro, trifluoromethyl, silyl, cyano, and alcohol functionalities are compatible with the reaction conditions. PMID:21786825
A new vibrator to stimulate muscle proprioceptors in fMRI.
Montant, Marie; Romaiguère, Patricia; Roll, Jean-Pierre
2009-03-01
Studying cognitive brain functions by functional magnetic resonance imaging (fMRI) requires appropriate stimulation devices that do not interfere with the magnetic fields. Since the emergence of fMRI in the 90s, a number of stimulation devices have been developed for the visual and auditory modalities. Only few devices, however, have been developed for the somesthesic modality. Here, we present a vibration device for studying somesthesia that is compatible with high magnetic field environments and that can be used in fMRI machines. This device consists of a poly vinyl chloride (PVC) vibrator containing a wind turbine and of a pneumatic apparatus that controls 1-6 vibrators simultaneously. Just like classical electromagnetic vibrators, our device stimulates muscle mechanoreceptors (muscle spindles) and generates reliable illusions of movement. We provide the fMRI compatibility data (phantom test), the calibration curve (vibration frequency as a function of air flow), as well as the results of a kinesthetic test (perceived speed of the illusory movement as a function of vibration frequency). This device was used successfully in several brain imaging studies using both fMRI and magnetoencephalography.
Wang, Lu; Dembecki, Jill; Jaffe, Neil E; O'Mara, Brian W; Cai, Hui; Sparks, Colleen N; Zhang, Jian; Laino, Sarah G; Russell, Reb J; Wang, Michelle
2013-09-20
Cleaning-in-place (CIP) for column chromatography plays an important role in therapeutic protein production. A robust and efficient CIP procedure ensures product quality, improves column life time and reduces the cost of the purification processes, particularly for those using expensive affinity resins, such as MabSelect protein A resin. Cleaning efficiency, resin compatibility, and facility compatibility are the three major aspects to consider in CIP process design. Cleaning MabSelect resin with 50mM sodium hydroxide (NaOH) along with 1M sodium chloride is one of the most popular cleaning procedures used in biopharmaceutical industries. However, high concentration sodium chloride is a leading cause of corrosion in the stainless steel containers used in large scale manufacture. Corroded containers may potentially introduce metal contaminants into purified drug products. Therefore, it is challenging to apply this cleaning procedure into commercial manufacturing due to facility compatibility and drug safety concerns. This paper reports a safe, effective and environmental and facility-friendly cleaning procedure that is suitable for large scale affinity chromatography. An alternative salt (sodium sulfate) is used to prevent the stainless steel corrosion caused by sodium chloride. Sodium hydroxide and salt concentrations were optimized using a high throughput screening approach to achieve the best combination of facility compatibility, cleaning efficiency and resin stability. Additionally, benzyl alcohol is applied to achieve more effective microbial control. Based on the findings, the recommended optimum cleaning strategy is cleaning MabSelect resin with 25 mM NaOH, 0.25 M Na2SO4 and 1% benzyl alcohol solution every cycle, followed by a more stringent cleaning using 50 mM NaOH with 0.25 M Na2SO4 and 1% benzyl alcohol at the end of each manufacturing campaign. A resin life cycle study using the MabSelect affinity resin demonstrates that the new cleaning strategy prolongs resin life time and consistently delivers high purity drug products. Copyright © 2013 Elsevier B.V. All rights reserved.
Jenke, Dennis; Couch, Tom; Gillum, Amy
2010-01-01
Material/water equilibrium binding constants (E(b)) were determined for 11 organic solutes and 2 plastic materials commonly used in pharmaceutical product containers (plasticized polyvinyl chloride and polyolefin). In general, solute binding by the plasticized polyvinyl chloride material was greater, by nearly an order of magnitude, than the binding by the polyolefin (on an equal weight basis). The utilization of the binding constants to facilitate container compatibility assessments (e.g., drug loss by container binding) for drug-containing products is discussed.
Kupie, Thomas C; Trusley, Craig; Ben, Michel; Trissel, Lawrence A
2008-09-15
The physical and chemical compatibility of palonosetron hydrochloride with atropine sulfate, famotidine, heparin sodium, lidocaine hydrochloride, and potassium chloride during simulated Y-site administration were studied. Test samples were prepared in duplicate by separately mixing 7.5-mL samples of undiluted palonosetron hydrochloride 50 microg/mL with 7.5-mL samples of atropine sulfate 0.4 mg/mL, famotidine 2 mg/mL, undiluted heparin sodium 100 units/mL, lidocaine hydrochloride 10 mg/mL, and potassium chloride 0.1 meq/mL diluted in 5% dextrose in colorless 15-mL borosilicate glass screw-cap culture tubes with polypropylene caps. Physical stability of the admixtures was assessed by visual examination and by measuring turbidity and particle size and content. Chemical stability of atropine sulfate, famotidine, heparin sodium, and lidocaine hydrochloride was assessed by stability-indicating high-performance liquid chromatography. Potassium chloride concentration was determined by indirect potentiometry using a potassiumion selective electrode. All of the samples of palonosetron hydrochloride with the test drugs were initially clear and colorless in normal fluorescent room light and when viewed with a Tyndall beam. Changes in turbidity for the samples were minor throughout the study. Measured particulates of 10 mum or larger were found to be few in number in all samples and remained so throughout the observation period. The admixtures remained colorless throughout the study. No loss of palonosetron hydrochloride occurred with any of the drugs over four hours. Similarly, little or no loss of the other drugs occurred in four hours. Palonosetron hydrochloride is physically and chemically stable with atropine sulfate, famotidine, heparin sodium, lidocaine hydrochloride, and potassium chloride during simulated Y-site administration.
Evaluation of Protamine as a Disinfectant for Contact Lenses.
Bandara, Mahesh K; Masoudi, Simin; Zhu, Hua; Bandara, Rani; Willcox, Mark D P
2016-11-01
To investigate the ability of protamine, alone or in combination with other antimicrobial agents, to kill bacteria and fungi associated with contact lens-related keratitis. The International Organization for Standardization 14729:2001 procedure was used to test the antimicrobial activity of solutions of protamine (23-228 μM) with and without polyhexamethylene biguanide (PHMB) and ethylenediamine tetra-acetic acid (EDTA). The recommended ISO panel of microbes along with six clinical isolates was tested. The effect of increasing sodium chloride concentration on the antimicrobial activity was also assessed. The cytotoxicity of the final protamine/EDTA/PHMB solution was measured using ISO 10993-5 standard assays. Protamine gave a dose-dependent antimicrobial effect, with the highest effect for most strains being at 228 μM (≥6 log reductions of viable bacteria and ≥1 log reduction of viable fungi). Addition of EDTA and PHMB increased the antimicrobial effect for all strains except Pseudomonas aeruginosa ATCC6538, which had optimum activity (≥6 log inhibition) even in protamine alone. The optimum antimicrobial activity of all microbes was achieved in 0.2% sodium chloride, but even in 0.8% sodium chloride, the activity met or exceeded the ISO standard (>3 log reductions for bacteria and >1 log reduction for fungi). None of the formulations was cytotoxic to mammalian cells. This study highlights the potential for protamine to be used for the development of effective multipurpose disinfection solutions. Further investigations such as stability, compatibility with contact lenses, and in vivo toxicity are warranted.
Evaluation of Selected Chemical Processes for Production of Low-cost Silicon, Phase 3
NASA Technical Reports Server (NTRS)
Blocher, J. M.; Browning, M. F.
1979-01-01
Refinements of the design of the 50 MT/year Experimental Process System Development Unit were made and competitive bids were received from mechanical, electrical, and structural contractors. Bids on most of the equipment were received and cataloged. Emergency procedures were defined to counter a variety of contingencies disclosed in operations and safety reviews. Experimental work with an electrolytic cell for zinc chloride disclosed no significant increase in power efficiency by steps taken to increase electrolyte circulation. On the basis of materials compatibility and permeability tests, 310 stainless steel was chosen for the shell of the fluidized-bed reactor and SiC-coated graphite for the liner.
NASA Astrophysics Data System (ADS)
Meng, Na; Zhang, Shuang-Quan; Zhou, Ning-Lin; Shen, Jian
2010-05-01
Heparin is a potent anticoagulant agent that interacts strongly with antithrombin III to prevent the formation of fibrin clots. In the present work, poly(dimethylsiloxane)(PDMS)/graphite oxide-benzalkonium chloride-heparin (PDMS/modified graphite oxide) nanocomposite films were obtained by the solution intercalation technique as a possible drug delivery system. The heparin-benzalkonium chloride (BAC-HEP) was intercalated into graphite oxide (GO) layers to form GO-BAC-HEP (modified graphite oxide). Nanocomposite films were characterized by XRD, SEM, TEM, ATR-FTIR and TGA. The modified graphite oxide was observed to be homogeneously dispersed throughout the PDMS matrix. The effect of modified graphite oxide on the mechanical properties of the nanocomposite film was investigated. When the modified graphite oxide content was lower than 0.2 wt%, the nanocomposites showed excellent mechanical properties. Furthermore, nanocomposite films become delivery systems that release heparin slowly to make the nanocomposite films blood compatible. The in vitro studies included hemocompatibility testing for effects on platelet adhesion, platelet activation, plasma recalcification profiles, and hemolysis. Results from these studies showed that the anticoagulation properties of PDMS/GO-BCA-HEP nanocomposite films were greatly superior to those for no treated PDMS. Cell culture assay indicated that PDMS/GO-BCA-HEP nanocomposite films showed enhanced cell adhesion.
Chen, Yadan; Wang, Tao; Helmy, Roy; Zhou, George X; LoBrutto, Rosario
2002-07-01
A potentiometric titration method for methyl magnesium chloride and other Grignard reagents based on the reaction with 2-butanol in THF has been developed and validated. The method employs a commercially available platinum electrode, using an electrolyte compatible with non-aqueous solvents. Well-defined titration curves were obtained, along with excellent method precision. The endpoint was precisely determined based on the first derivative of the titration curve. Different solvents such as THF, diethyl ether and methylene chloride provided similar results with regard to sharpness of the endpoint and method precision. The method was applied to a wide array of Grignard reagents including methyl magnesium bromide, ethyl magnesium chloride, propyl magnesium chloride, vinyl magnesium chloride, phenyl magnesium chloride, and benzyl magnesium chloride with similar precision and accuracy. Application of in-line FTIR was demonstrated for in situ monitoring of the titration reaction, allowing characterization of the reaction species. An authentic spectrum of the MeMgCl-THF complex was obtained using spectral subtraction and the vibrational absorbance bands were identified. FTIR also provided an alternative for detecting the titration endpoint, and the titration results so obtained, provided a cross-validation of the accuracy of the potentiometric titration.
Saum, Stephan H; Müller, Volker
2008-01-01
The moderate halophile Halobacillus halophilus is the paradigm for chloride dependent growth in prokaryotes. Recent experiments shed light on the molecular basis of the chloride dependence that is reviewed here. In the presence of moderate salinities Halobacillus halophilus mainly accumulates glutamine and glutamate to adjust turgor. The transcription of glnA2 (encoding a glutamine synthetase) as well as the glutamine synthetase activity were identified as chloride dependent steps. Halobacillus halophilus switches its osmolyte strategy and produces proline as the main compatible solute at high salinities. Furthermore, Halobacillus halophilus also shifts its osmolyte strategy at the transition from the exponential to the stationary phase where proline is exchanged by ectoine. Glutamate was found as a “second messenger” essential for proline production. This observation leads to a new model of sensing salinity by sensing the physico-chemical properties of different anions. PMID:18442383
Lu, Zhe; Wilsily, Ashraf; Fu, Gregory C.
2011-01-01
A new family of stereoconvergent cross-couplings of unactivated secondary alkyl electrophiles has been developed, specifically, arylamine-directed alkyl–alkyl Suzuki reactions. This represents the first such investigation to be focused on the use of alkyl chlorides as substrates. Structure-enantioselectivity studies are consistent with the nitrogen, not the aromatic ring, serving as the primary site of coordination of the arylamine to the catalyst. The rate law for this asymmetric cross-coupling is compatible with transmetalation being the turnover-limiting step of the catalytic cycle. PMID:21553917
Myers, Alan L; Zhang, Yanping; Kawedia, Jitesh D; Shank, Brandon R; Deaver, Melissa A; Kramer, Mark A
2016-12-15
The chemical stability and physical compatibility of tacrolimus i.v. infusion solutions prepared in Excel bags and stored at 23 or 4 °C for up to nine days were studied. Tacrolimus admixtures (2, 4, and 8 μg/mL) were prepared in Excel bags using 0.9% sodium chloride injection and stored at 23 °C without protection from light or at 4 °C in the dark. Test samples were withdrawn from triplicate bag solutions immediately after preparation and at predetermined time intervals (1, 3, 5, 7, and 9 days). Chemical stability was assessed by measuring tacrolimus concentrations using a validated stability-indicating high-performance liquid chromatography assay. The physical stability of the admixtures was assessed by visual examination and by measuring turbidity, particle size, and drug content. All test solutions stored at 23 or 4 °C had a no greater than 6% loss of the initial tacrolimus concentration throughout the nine-day study period. All test samples of tacrolimus admixtures, under both storage conditions, were without precipitation and remained clear initially and throughout the nine-day observation period. Changes in turbidities were minor; measured particulates remained few in number in all samples throughout the study. Extemporaneously prepared infusion solutions of tacrolimus 2, 4, and 8 μg/mL in 0.9% sodium chloride injection in Excel bags were chemically and physically stable for at least nine days when stored at room temperature (23 °C) without protection from light and when stored in a refrigerator (4 °C) in the dark. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Johnston, Richard H.; Bush, Peter W.; Krause, Richard E.; Miller, James A.; Sprinkle, Craig L.
1982-01-01
A summary of hydrologic testing in an offshore oil-test well (LB427) drilled for Tenneco, Inc., 55 miles east of Fernandina Beach, Florida, is presented. The interval tested (1,050 to 1,070 feet below sea level) is in a calcarenite that is equivalent to the Ocala Limestone (late Eocene) of onshore Florida and South Georgia. At this site the Ocala forms the highly productive Tertiary limestone aquifer system of the southeastern United States. Pressure-head measurements indicate an equivalent freshwater head of 24 to 29 feet above sea level. These pressure-head measurements and an earlier one made in the nearby JOIDES J- I hole are the only hydraulic head determinations to date in the offshore extensions of any of the aquifers underlying the Atlantic coastal plain. A drill-stem test recovered water samples containing about 7,000 milligrams per liter chloride. However, seawater used in the drilling process apparently contaminated the samples and the formation water is considered slightly fresher. The head and salinity data from the Tenneco well suggest that the sampled interval lies in the transition zone between fresh and seawater in the limestone aquifer. These data, when viewed with similar data from JOIDES J-I, show the transition zone to slope very slightly landward. The interface position is probably intermediate between a position compatible with present-day heads and a position compatible with predevelopment heads.
The diagnosis of cystic fibrosis.
De Boeck, Kris; Vermeulen, Francois; Dupont, Lieven
2017-06-01
Establishing the diagnosis of cystic fibrosis (CF) is straight forward in the majority of patients: they present with a clear clinical picture (most frequently chronic respiratory symptoms plus malabsorption), the sweat chloride value is>60mmol/L and two known disease causing CFTR mutations are identified. In less than 5% of subjects, mainly those with a milder or limited phenotype, the diagnostic process is more complex, because initial diagnostic test results are inconclusive: sweat chloride concentration in the intermediate range, less than 2 CF causing mutations identified or both. These patients should be referred to expert centers where bioassays of CFTR function like nasal potential difference measurement or intestinal current measurement can be done. Still, in some patients, despite symptoms compatible with CF and some indication of CFTR dysfunction (e.g. only intermediate sweat chloride value), diagnostic criteria are not met (e.g. only 1 CFTR mutation identified). For these subjects, the term CFTR related disorder (CFTR-RD) is used. Patients with disseminated bronchiectasis, congenital bilateral absence of the vas deferens and acute or recurrent pancreatitis may fall in this category. CF has a very wide disease spectrum and increasingly the diagnosis is being made during adult life, mainly in subjects with milder phenotypes. In many countries, nationwide CF newborn screening (NBS) has been introduced. In screen positive babies, the diagnosis of CF must be confirmed by a sweat test demonstrating a sweat chloride concentration above 60mmol/L. To achieve the benefit of NBS, every baby in whom the diagnosis of CF is confirmed must receive immediate follow-up and treatment in a CF reference center. CF NBS is not full proof: some diagnoses will be missed and in some babies the diagnosis cannot be confirmed nor ruled out with certainty. Screening algorithms that include gene sequencing will detect a high number of such babies that are screen positive with an inconclusive diagnosis (CFSPID). Even in 2016, the most reliable and widely available diagnostic test for CF is the measurement of chloride concentration in sweat. The method of choice is sweat induction by pilocarpine iontophoresis, followed by sweat collection on a gauze or filter paper or in a Macroduct coil. Since mutation specific therapies have become available, it is important to identify the mutations responsible for CF in each individual patient. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Chloride Blood Test: MedlinePlus Lab Test Information
... https://medlineplus.gov/labtests/chloridebloodtest.html Chloride Blood Test To use the sharing features on this page, please enable JavaScript. What is a Chloride Blood Test? A chloride blood test measures the amount of ...
NASA Technical Reports Server (NTRS)
Geer, Richard D.
1989-01-01
To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.
Compatibility of azathioprine sodium with intravenous fluids.
Johnson, C A; Porter, W A
1981-06-01
The effects of storage containers, diluent, temperature, and illumination on the stability and compatibility of azathioprine sodium were studied. Reconstituted solutions were stored in the manufacturer's vial and a plastic syringe. Diluted solutions were stored in mini-bags mixed with standard intravenous solutions (5% dextrose injection, 0.9% sodium chloride injection, and 0.45% sodium chloride injection). Samples were stored at 4 degrees C in the dark and at 23 degrees C under constant illumination. Samples containing an internal standard, 6-methylmercaptopurine, were assayed by ion exchange chromatography at 0, 8, and 16 days. Accelerated decomposition studies at 70 degrees C also were performed to determine the chromatographic method's capability for separating azathioprine from its breakdown products. No solutions or admixtures differed significantly (p greater than 0.13) from initial concentrations after 16 days at 23 degrees C under constant illumination. Mixture with 5% dextrose injection caused precipitation by day 16. Azathioprine sodium reconstituted and stored in the manufacturer's vial or a plastic syringe at 4 degrees C formed a precipitate by day 4. Sterility is the limiting factor determining suitability for use of azathioprine solutions kept less than four days.
NASA Astrophysics Data System (ADS)
İmren, Dilek; Boztuğ, Ali; Yılmaz, Ersen; Zengin, H. Bayram
2008-11-01
In this study, a blend of poly(vinyl chloride) (PVC)/ethylene-co-vinyl acetate (EVA) was compatibilized by terpolymer of maleic anhydride-styrene-vinyl acetate (MAStVA) used as a compatibilizer. It was prepared the blends of 50/50 PVC/EVA containing 2-10% of the terpolymer. The compatibility experiences of these blends were investigated by using viscometric method in the range of concentrations (0.5-2.0 g dL -1) where tetrahydrofuran (THF) is the solvent. The interaction parameter (Δ b) was used to study the miscibility and compatibility of polymer blend in solution, obtained from the modified Krigbaum and Wall theory. Turbidity and FTIR measurements were also used to investigate the miscibility of this pair of polymers. The values of the relative viscosities of the each polymer solution and their blends were measured by a Cannon-Fenske type viscometer. In consequence of the study, it was observed that a considerable improvement was achieved in the miscibility of PVC/EVA blends by adding among 5 and 10 wt% of compatibilizer.
Compatibility and activity of enoxaparin sodium in 0.9% sodium chloride injection for 48 hours.
Mewborn, A L; Kessler, J M; Joyner, K A
1996-01-15
The stability of enoxaparin sodium in 0.9% sodium chloride injection in polyvinyl chloride (PVC) containers was studied. Triplicate solutions of 120 mg (1.2 mL) of enoxaparin (as the sodium salt) and 98.8 mL of 0.9% sodium chloride injection were prepared in 250-mL PVC containers and stored at room temperature (20-22 degrees C). Samples were taken immediately after preparation and at 0.25, 0.5, 0.75, 1, 4, 12, 16, 24, and 48 hours. Inspections for color change and precipitation were performed with a clarity inspection station and a magnifying glass. Samples of the three admixtures were evaluated in duplicate for pharmacologic activity by an automated coagulation heparin assay. Throughout the 48-hour study period, the enoxaparin admixtures were free of color change, evolution of gas, and precipitates. The pharmacologic activity of enoxaparin in the PVC containers remained > 94% of the initial measured activity for 48 hours. Enoxaparin 1.2 mg/mL (as the sodium salt) in 0.9% sodium chloride injection in PVC containers was stable for up to 48 hours at 20-22 degrees C.
Schreiner, Madeleine; Schlesinger, Ramona; Heberle, Joachim; Niemann, Hartmut H
2016-09-01
The transmembrane pump halorhodopsin in halophilic archaea translocates chloride ions from the extracellular to the cytoplasmic side upon illumination. In the ground state a tightly bound chloride ion occupies the primary chloride-binding site (CBS I) close to the protonated Schiff base that links the retinal chromophore to the protein. The light-triggered trans-cis isomerization of retinal causes structural changes in the protein associated with movement of the chloride ion. In reverse, chemical depletion of CBS I in Natronomonas pharaonis halorhodopsin (NpHR) through deprotonation of the Schiff base results in conformational changes of the protein: a state thought to mimic late stages of the photocycle. Here, crystals of Halobacterium salinarum halorhodopsin (HsHR) were soaked at high pH to provoke deprotonation of the Schiff base and loss of chloride. The crystals changed colour from purple to yellow and the occupancy of CBS I was reduced from 1 to about 0.5. In contrast to NpHR, this chloride depletion did not cause substantial conformational changes in the protein. Nevertheless, two observations indicate that chloride depletion could eventually result in structural changes similar to those found in NpHR. Firstly, the partially chloride-depleted form of HsHR has increased normalized B factors in the region of helix C that is close to CBS I and changes its conformation in NpHR. Secondly, prolonged soaking of HsHR crystals at high pH resulted in loss of diffraction. In conclusion, the conformation of the chloride-free protein may not be compatible with this crystal form of HsHR despite a packing arrangement that hardly restrains helices E and F that presumably move during ion transport.
Kaiser, Jeanette; Krämer, Irene
2012-06-01
The aim of this study was to investigate the physicochemical stability of clofarabine (CAFdA) injection concentrate and ready-to-use CAFdA infusion solutions over a prolonged period of 28 days. To determine the stability of CAFdA infusion solutions, the injection concentrate (Evoltra®, 1 mg/mL, Genzyme) was diluted either with 0.9% sodium chloride or 5% glucose infusion solution. The resulting concentrations of 0.2 mg/mL or 0.6 mg/mL, respectively, were chosen to represent the lower and upper limit of the ordinary concentration range. Test solutions were stored under refrigeration (2-8°C) or at room temperature either light protected or exposed to light. CAFdA concentrations and pH values were determined at different time intervals throughout a 28-day storage period. Compatibility of diluted CAFdA infusion solutions (0.1-0.4 mg/mL) with different container materials (polyvinyl chloride (PVC), glass, and polypropylene/polyethylene (PP/PE)) was tested over a 48-h storage period. CAFdA concentrations were measured by a stability-indicating reversed phase high-performance liquid chromatography (HPLC) assay with ultraviolet detection. CAFdA injection concentrate and CAFdA infusion solutions remained physicochemically stable (>90% CAFdA) for 4 weeks. Results are independent of storage conditions, drug concentrations (0.2, 0.6, and 1.0 mg/mL) and diluents (0.9% sodium chloride, 5% glucose infusion solution). Adsorption of CAFdA to container material can be excluded. CAFdA injection concentrate and diluted infusion solutions in commonly used vehicles are stable for at least 28 days either refrigerated or at room temperature. Physicochemical stability favors pharmacy-based centralized preparation. Due to microbiological reasons, strict aseptic handling and storage of the products under refrigeration is recommended.
Hygroscopic salts and the potential for life on Mars.
Davila, Alfonso F; Duport, Luis Gago; Melchiorri, Riccardo; Jänchen, Jochen; Valea, Sergio; de Los Rios, Asunción; Fairén, Alberto G; Möhlmann, Diedrich; McKay, Christopher P; Ascaso, Carmen; Wierzchos, Jacek
2010-01-01
Hygroscopic salts have been detected in soils in the northern latitudes of Mars, and widespread chloride-bearing evaporitic deposits have been detected in the southern highlands. The deliquescence of hygroscopic minerals such as chloride salts could provide a local and transient source of liquid water that would be available for microorganisms on the surface. This is known to occur in the Atacama Desert, where massive halite evaporites have become a habitat for photosynthetic and heterotrophic microorganisms that take advantage of the deliquescence of the salt at certain relative humidity (RH) levels. We modeled the climate conditions (RH and temperature) in a region on Mars with chloride-bearing evaporites, and modeled the evolution of the water activity (a(w)) of the deliquescence solutions of three possible chloride salts (sodium chloride, calcium chloride, and magnesium chloride) as a function of temperature. We also studied the water absorption properties of the same salts as a function of RH. Our climate model results show that the RH in the region with chloride-bearing deposits on Mars often reaches the deliquescence points of all three salts, and the temperature reaches levels above their eutectic points seasonally, in the course of a martian year. The a(w) of the deliquescence solutions increases with decreasing temperature due mainly to the precipitation of unstable phases, which removes ions from the solution. The deliquescence of sodium chloride results in transient solutions with a(w) compatible with growth of terrestrial microorganisms down to 252 K, whereas for calcium chloride and magnesium chloride it results in solutions with a(w) below the known limits for growth at all temperatures. However, taking the limits of a(w) used to define special regions on Mars, the deliquescence of calcium chloride deposits would allow for the propagation of terrestrial microorganisms at temperatures between 265 and 253 K, and for metabolic activity (no growth) at temperatures between 253 and 233 K.
Schwendner, Petra; Bohmeier, Maria; Rettberg, Petra; Beblo-Vranesevic, Kristina; Gaboyer, Frédéric; Moissl-Eichinger, Christine; Perras, Alexandra K.; Vannier, Pauline; Marteinsson, Viggó T.; Garcia-Descalzo, Laura; Gómez, Felipe; Malki, Moustafa; Amils, Ricardo; Westall, Frances; Riedo, Andreas; Monaghan, Euan P.; Ehrenfreund, Pascale; Cabezas, Patricia; Walter, Nicolas; Cockell, Charles
2018-01-01
Growth in sodium chloride (NaCl) is known to induce stress in non-halophilic microorganisms leading to effects on the microbial metabolism and cell structure. Microorganisms have evolved a number of adaptations, both structural and metabolic, to counteract osmotic stress. These strategies are well-understood for organisms in NaCl-rich brines such as the accumulation of certain organic solutes (known as either compatible solutes or osmolytes). Less well studied are responses to ionic environments such as sulfate-rich brines which are prevalent on Earth but can also be found on Mars. In this paper, we investigated the global metabolic response of the anaerobic bacterium Yersinia intermedia MASE-LG-1 to osmotic salt stress induced by either magnesium sulfate (MgSO4) or NaCl at the same water activity (0.975). Using a non-targeted mass spectrometry approach, the intensity of hundreds of metabolites was measured. The compatible solutes L-asparagine and sucrose were found to be increased in both MgSO4 and NaCl compared to the control sample, suggesting a similar osmotic response to different ionic environments. We were able to demonstrate that Yersinia intermedia MASE-LG-1 accumulated a range of other compatible solutes. However, we also found the global metabolic responses, especially with regard to amino acid metabolism and carbohydrate metabolism, to be salt-specific, thus, suggesting ion-specific regulation of specific metabolic pathways. PMID:29535699
Advanced intermediate temperature sodium copper chloride battery
NASA Astrophysics Data System (ADS)
Yang, Li-Ping; Liu, Xiao-Min; Zhang, Yi-Wei; Yang, Hui; Shen, Xiao-Dong
2014-12-01
Sodium metal chloride batteries, also called as ZEBRA batteries, possess many merits such as low cost, high energy density and high safety, but their high operation temperature (270-350 °C) may cause several issues and limit their applications. Therefore, decreasing the operation temperature is of great importance in order to broaden their usage. Using a room temperature ionic liquid (RTIL) catholyte composed of sodium chloride buffered 1-ethyl-3-methylimidazolium chloride-aluminum chloride and a dense β″-aluminates solid electrolyte film with 500 micron thickness, we report an intermediate temperature sodium copper chloride battery which can be operated at only 150 °C, therefore alleviating the corrosion issues, improving the material compatibilities and reducing the operating complexities associated with the conventional ZEBRA batteries. The RTIL presents a high ionic conductivity (0.247 S cm-1) at 150 °C and a wide electrochemical window (-2.6 to 2.18 vs. Al3+/Al). With the discharge plateau at 2.64 V toward sodium and the specific capacity of 285 mAh g-1, this intermediate temperature battery exhibits an energy density (750 mWh g-1) comparable to the conventional ZEBRA batteries (728-785 mWh g-1) and superior to commercialized Li-ion batteries (550-680 mWh g-1), making it very attractive for renewable energy integration and other grid related applications.
Soucek, David J; Dickinson, Amy
2016-09-01
While it has been well established that increasing chloride concentration in water reduces the toxicity of nitrite to freshwater species, little work has been done to investigate the effect of chloride on nitrate toxicity. We conducted acute and chronic nitrate (as sodium nitrate) toxicity tests with the cladoceran Ceriodaphnia dubia and the amphipod Hyalella azteca (chronic tests only) over a range of chloride concentrations spanning natural chloride levels found in surface waters representative of watersheds of the Great Lakes Region. Chronic nitrate toxicity test results with both crustaceans were variable, with H. azteca appearing to be one of the more sensitive invertebrate species tested and C. dubia being less sensitive. While the variability in results for H. azteca were to an extent related to chloride concentration in test water that was distinctly not the case for C. dubia. We concluded that the chloride dependent toxicity of nitrate is not universal among freshwater crustaceans. An additional sodium chloride chronic toxicity test with the US Lab strain of H. azteca in the present study suggested that when present as predominantly sodium chloride and with relatively low concentrations of other ions, there is a narrow range of chloride concentrations over which this strain is most fit, and within which toxicity test data are reliable.
The compatibility and stability of midazolam and dexamethasone in infusion solutions.
Good, Phillip D; Schneider, Jennifer J; Ravenscroft, Peter J
2004-05-01
The delivery of subcutaneous medication by continuous infusion is common in palliative medicine. Many centers combine multiple medications, but the analytical confirmation of the compatibility and stability of these combinations has rarely been performed. This study examined the compatibility and stability of midazolam and dexamethasone using high performance liquid chromatography. Nine different solutions were prepared in polypropylene syringes by combining these two drugs with 0.9% sodium chloride. When these two drugs were combined in a syringe, there was significant loss of midazolam over 48 hours, with only 60-80% of the initial concentration remaining in syringes stored at 35-39 degrees C. This study demonstrates that cloudiness of a solution is not the only predictor of drug loss and that drug loss may occur even in solutions that remain clear at time of preparation. The clinical implications of these results are that dexamethasone and midazolam should not be combined in syringe driver solutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fifield, Leonard S.; Simmons, Kevin L.; Laddha, Sachin
2010-05-17
Plant-based bio-fiber has the potential to achieve weight and cost savings over glass fiber in automotive polymer composites if moisture stability and fiber-resin compatibility issues can be solved. This paper describes the compression molding of 50vol% 2 inch random nonwoven mat kenaf fiber vinyl ester composites with and without chemical resin additives intended to improve moisture stability and resin compatibility. The 2wt% addition of n-undecanoyl chloride or 10-undecenoyl chloride to the styrene-based resin prior to molding of the kenaf composites was observed to decrease the 24hr, 25oC moisture uptake of the molded panels by more than 50%. The tensile stiffnessmore » and flexural stiffness of the soaked panels containing these additives were seen to increase by more than 30% and 70%, respectively, relative to panels made with no additives. While ‘dry’ panel (50% relative humidity at 25oC) strengths did not significantly change in the presence of the additives, tensile strength was observed to increase by more than 40% and flexural strength more than doubled for the soaked panels.« less
Emiralioğlu, Nagehan; Özçelik, Uğur; Yalçın, Ebru; Doğru, Deniz; Kiper, Nural
2016-01-01
Sweat test with Gibson Cooke (GC) method is the diagnostic gold standard for cystic fibrosis (CF). Recently, alternative methods have been introduced to simplify both the collection and analysis of sweat samples. Our aim was to compare sweat chloride values obtained by GC method with other sweat test methods in patients diagnosed with CF and whose CF diagnosis had been ruled out. We wanted to determine if the other sweat test methods could reliably identify patients with CF and differentiate them from healthy subjects. Chloride concentration was measured with GC method, chloride meter and sweat test analysis system; also conductivity was determined with sweat test analysis system. Forty eight patients with CF and 82 patients without CF underwent the sweat test, showing median sweat chloride values 98.9 mEq/L with GC method, 101 mmol/L with chloride meter, 87.8 mmol/L with sweat test analysis system. In non-CF group, median sweat chloride values were 16.8 mEq/L with GC method, 10.5 mmol/L with chloride meter, and 15.6 mmol/L with sweat test analysis system. Median conductivity value was 107.3 mmol/L in CF group and 32.1 mmol/L in non CF group. There was a strong positive correlation between GC method and the other sweat test methods with a statistical significance (r=0.85) in all subjects. Sweat chloride concentration and conductivity by other sweat test methods highly correlate with the GC method. We think that the other sweat test equipments can be used as reliably as the classic GC method to diagnose or exclude CF.
Verification of chloride adsorption effect of mortar with salt adsorbent
NASA Astrophysics Data System (ADS)
Hoshina, T.; Nakajima, N.; Sudo, H.; Date, S.
2017-11-01
In order to investigate the chloride adsorption effect of mortar mixed with chloride adsorbent, electrophoresis test using mortar specimen and immersion dry repeated test were conducted to evaluate chloride adsorption effect. As a result, it was confirmed that soluble salt content that causes corrosion of rebar in the specimen was reduced by the chloride adsorbent and corrosion inhibiting effect of the rebar was also obtained. It was also confirmed that by increasing dosage of the chloride adsorbent, the chloride adsorbing effect becomes larger as well..
Hydrolysis of ferric chloride in solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lussiez, G.; Beckstead, L.
1996-11-01
The Detox{trademark} process uses concentrated ferric chloride and small amounts of catalysts to oxidize organic compounds. It is under consideration for oxidizing transuranic organic wastes. Although the solution is reused extensively, at some point it will reach the acceptable limit of radioactivity or maximum solubility of the radioisotopes. This solution could be cemented, but the volume would be increased substantially because of the poor compatibility of chlorides and cement. A process has been developed that recovers the chloride ions as HCl and either minimizes the volume of radioactive waste or permits recycling of the radioactive chlorides. The process involves amore » two-step hydrolysis at atmospheric pressure, or preferably under a slight vacuum, and relatively low temperature, about 200{degrees}C. During the first step of the process, hydrolysis occurs according to the reaction below: FeCl{sub 3 liquid} + H{sub 2}O {r_arrow} FeOCl{sub solid} + 2 HCl{sub gas} During the second step, the hot, solid, iron oxychloride is sprayed with water or placed in contact with steam, and hydrolysis proceeds to the iron oxide according to the following reaction: 2 FeOCl{sub solid} + H{sub 2}O {r_arrow} Fe{sub 2}O{sub 3 solid} + 2 HCl{sub gas}. The iron oxide, which contains radioisotopes, can then be disposed of by cementation or encapsulation. Alternately, these chlorides can be washed off of the solids and can then either be recycled or disposed of in some other way.« less
Chen, Fuchao; Fang, Baoxia; Li, Peng; Zhu, Xuesong; Zhou, Benhong
2014-08-01
This study was to investigate the physical and chemical compatibility of butorphanol with tramadol or fentanyl in 0.9% sodium chloride injections for patient controlled analgesia administration. The solutions were prepared in polyvinyl chloride (PVC) infusion bags and stored without protected from light exposure at room temperature (25 degrees C) or refrigerated (4 degrees C). Over a period of 168 hours, stabilities were determined by visual inspection, pH measurement, and high-pressure liquid chromatography (HPLC) assay of drug concentrations. At both temperatures, admixtures of butorphanol-tramadol and butorphanol-fentanyl were clear in appearance, and no color change or precipitation was observed during the study period. The maximum losses obtained were lower than 5% for the three drugs after 168 hours of storage. The results indicate that, at ambient or refrigerated storage conditions, the drug mixtures of butorphanol-tramadol and butorphanol-fentanyl in 0.9% sodium chloride injections were physically and chemically stable for at least 168 hours when stored in PVC syringes.
Chen, Fu-Chao; Zhu, Jun; Li, Bin; Yuan, Fang-Jun; Wang, Lin-Hai
2016-01-01
Mixing 5-hydroxytryptamine-3 (5-HT3) receptor antagonists with patient-controlled analgesia (PCA) solutions of tramadol has been shown to decrease the incidence of nausea and vomiting associated with the use of tramadol PCA for postoperative pain. However, such mixtures are not commercially available, and the stability of the drug combinations has not been duly studied. The study aimed to evaluate the stability of tramadol with three 5-HT3 receptor antagonists in 0.9% sodium chloride injection for PCA administration. Test samples were prepared by adding 1,000 mg tramadol hydrochloride, 8 mg ondansetron hydrochloride, and 6 mg granisetron hydrochloride or 5 mg tropisetron hydrochloride to 100 mL of 0.9% sodium chloride injection in polyolefin bags. The samples were prepared in triplicates, stored at either 25°C or 4°C for 14 days, and assessed using the following compatibility parameters: precipitation, cloudiness, discoloration, and pH. Chemical stability was also determined using a validated high-pressure liquid chromatography method. All of the mixtures were clear and colorless throughout the initial observation period. No change in the concentration of tramadol hydrochloride occurred with any of the 5-HT3 receptor antagonists during the 14 days. Similarly, little or no loss of the 5-HT3 receptor antagonists occurred over the 14-day period. Our results suggest that mixtures of tramadol hydrochloride, ondansetron hydrochloride, granisetron hydrochloride, or tropisetron hydrochloride in 0.9% sodium chloride injection were physically and chemically stable for 14 days when stored in polyolefin bags at both 4°C and 25°C.
Serum chloride test ... A greater-than-normal level of chloride is called hyperchloremia. It may be due to: Carbonic anhydrase inhibitors (used to treat glaucoma) Diarrhea Metabolic acidosis Respiratory alkalosis (compensated) Renal ...
Gao, Jun; Manard, Benjamin Thomas; Castro, Alonso; ...
2017-02-02
Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of ninemore » materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.« less
Wang, Kai; Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao
2017-10-30
A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1-2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area.
Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao
2017-01-01
A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Jun; Manard, Benjamin Thomas; Castro, Alonso
Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of ninemore » materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.« less
Inhibition Of Washed Sludge With Sodium Nitrite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Congdon, J. W.; Lozier, J. S.
2012-09-25
This report describes the results of electrochemical tests used to determine the relationship between the concentration of the aggressive anions in washed sludge and the minimum effective inhibitor concentration. Sodium nitrate was added as the inhibitor because of its compatibility with the DWPF process. A minimum of 0.05M nitrite is required to inhibit the washed sludge simulant solution used in this study. When the worst case compositions and safety margins are considered, it is expected that a minimum operating limit of nearly 0.1M nitrite will be specified. The validity of this limit is dependent on the accuracy of the concentrationsmore » and solubility splits previously reported. Sodium nitrite additions to obtain 0.1M nitrite concentrations in washed sludge will necessitate the additional washing of washed precipitate in order to decrease its sodium nitrite inhibitor requirements sufficiently to remain below the sodium limits in the feed to the DWPF. Nitrite will be the controlling anion in "fresh" washed sludge unless the soluble chloride concentration is about ten times higher than predicted by the solubility splits. Inhibition of "aged" washed sludge will not be a problem unless significant chloride dissolution occurs during storage. It will be very important tomonitor the composition of washed sludge during processing and storage.« less
Surface resistivity test evaluation as an indicator of the chloride permeability of concrete.
DOT National Transportation Integrated Search
2012-12-01
Many agencies have adopted the standard tests for electrical : indication of concretes ability to resist chloride ion penetration : (AASHTO T 277 and ASTM C1202), commonly known as the rapid : chloride permeability test (RCPT), in their specificat...
NASA Astrophysics Data System (ADS)
Jain, Aayushi; Dixit, R. C.
2018-05-01
Pressure induced structural phase transition of NaCl-type (B1) to CsCl-type (B2) structure in Sodium Chloride NaCl are presented. An effective interionic interaction potential (EIOP) with long range Coulomb, van der Waals (vdW) interaction and the short-range repulsive interaction upto second-neighbor ions within the Hafemeister and Flygare approach with modified ionic charge is reported here. The reckon value of the phase transition pressure (Pt) and the magnitude of the discontinuity in volume at the transition pressure are compatible as compared with reported data. The variations of elastic constants and their combinations with pressure follow ordered behavior. The present approach has also succeeded in predicting the Born and relative stability criteria.
Ziegler, Andrew C.; Christensen, Victoria G.; Ross, Heather C.
1999-01-01
To investigate the feasbility of artificial recharge as a method of meeting future water-supply needs and to protect the Equus Beds aquifer from saltwater intrusion from natural and anthropogenic sources to the west, the Equus Beds Ground-Water Recharge from Demonstration Project was begun in 1995. The project is a cooperative effort between the city of Wichita and the Bureau of Reclamation, U.S. Department of the Interior. During the project, high flows from the Little Arkansas River are captured and recharged into the Equus Beds aquifer through recharge basins, a trench, or a recharge well, located at two recharge sites near Halstead and Sedgwick, Kansas. To document baseline concentrations and compatibility of stream (recharge) and aquifer water, the U.S. Geological Survey collected water samples from February 1995 through August 1998. These samples were analyzed for dissolved solids, total and dissolved inorganic constituents, nutrients, organic and volatile organic compounds, radionuclides, and bacteria. Results of baseline sampling indicated that the primary constituents of concern for recharge were sodium, chloride, nitrite plus nitrate, iron and manganese, total coliform bacteria, and atrazine. Chloride and atrazine were of particular concern because concentrations of these constituents in water from the Little Arkansas River frequently exceeded regulatory criteria. The Little Arkansas River is used as the source water for recharge. The U.S. Environmental Protection Agency Secondary Maximum Contaminant Level for chloride is 250 mg/L (milligrams per liter), and the Maximum Contaminant Level for atrazine is 3.0 ?g/L (micrograms per liter) as an annual mean. Baseline concentrations of chloride in surface water ranged from 8.0 to 400 ?g/L. Baseline concentrations of atrazine in surface water ranged from less than 0.10 to 46 ?g/L. Concentrations of chloride and atrazine have increased in water from some of the wells at both the Halstead and Sedgwick recharge sites after recharge began, although concentrations remained within the range of baseline values in the Equus Beds aquifer and are considerably less than U.S. Environmental Protection Agency drinking-water criteria. However, a substantial quantity of water has not been recharged at the Sedgwick site to determine the overall effects of artificial recharge on aquifer quality. Continued monitoring is necessary to determine long-term effects at both sites. Major ion and trace element concentrations in source water and receiving water were analyzed to determine the compatibility of recharge and receiving ground water for artificial recharge. Stiff diagrams of major ions were used to show the similarity or differences between source surface water and receiving ground water. The water from both sources, for the most part, was chemically compatible to the receiving aquifer water at both recharge sites. It may be possible to decrease the monitoring frequency at the Halstead recharge site because water-quality changes in receiving water at this site are very gradual. However, real-time water-quality monitoring of surrogates needs to be site specific for the determination of chloride and atrazine. Real-time water-quality monitoring potentially can be used to more effectively manage the artificial recharge process, enabling project officials to respond more rapidly to changes in water quality.
Elia, Giuseppe Antonio; Ducros, Jean-Baptiste; Sotta, Dane; Delhorbe, Virginie; Brun, Agnès; Marquardt, Krystan; Hahn, Robert
2017-11-08
Herein we report, for the first time, an overall evaluation of commercially available battery separators to be used for aluminum batteries, revealing that most of them are not stable in the highly reactive 1-ethyl-3-methylimidazolium chloride:aluminum trichloride (EMIMCl:AlCl 3 ) electrolyte conventionally employed in rechargeable aluminum batteries. Subsequently, a novel highly stable polyacrylonitrile (PAN) separator obtained by the electrospinning technique for application in high-performance aluminum batteries has been prepared. The developed PAN separator has been fully characterized in terms of morphology, thermal stability, and air permeability, revealing its suitability as a separator for battery applications. Furthermore, extremely good compatibility and improved aluminum interface stability in the highly reactive EMIMCl:AlCl 3 electrolyte were discovered. The use of the PAN separator strongly affects the aluminum dissolution/deposition process, leading to a quite homogeneous deposition compared to that of a glass fiber separator. Finally, the applicability of the PAN separator has been demonstrated in aluminum/graphite cells. The electrochemical tests evidence the full compatibility of the PAN separator in aluminum cells. Furthermore, the aluminum/graphite cells employing the PAN separator are characterized by a slightly higher delivered capacity compared to those employing glass fiber separators, confirming the superior characteristics of the PAN separator as a more reliable separator for the emerging aluminum battery technology.
40 CFR 60.2155 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... pollutant (particulate matter, hydrogen chloride, or opacity) over 3 consecutive years show that you comply... limitation for particulate matter, hydrogen chloride, or opacity, you may choose to conduct performance tests... matter, hydrogen chloride, or opacity, you must conduct annual performance tests for that pollutant until...
Chen, Fu-Chao; Xiong, Hui; Liu, Hui-Min; Fang, Bao-Xia; Li, Peng
2015-08-15
The stability of admixtures containing butorphanol and granisetron in polyolefin bags and glass bottles stored at 4 and 25 °C was studied. Commercial solutions of butorphanol tartrate and granisetron hydrochloride were combined and further diluted with 0.9% sodium chloride injection to final concentrations of butorphanol tartrate 0.08 mg/mL and granisetron 0.03 or 0.06 mg/mL; the resulting mixtures were packaged in polyolefin bags and glass bottles. The admixtures were assessed for periods of up to 48 hours after storage at 25 °C without protection from room light and up to 14 days at 4 °C with protection from room light. The chemical stability of the admixtures was evaluated by a validated high-performance liquid chromatography (HPLC) method and by measurement of pH values. Solution appearance and color were assessed by observing the samples against room light and dark backgrounds. HPLC analysis demonstrated that the percentages of the initial concentrations of butorphanol and granisetron in the various solutions remained above 97% during the testing period. No changes in color or turbidity were observed in any of the prepared solutions. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and granisetron 0.03 or 0.06 mg/mL in 0.9% sodium chloride injection in polyolefin bags or glass bottles remained stable for 48 hours when stored at 25 °C exposed to room light and for 14 days when stored at 4 °C protected from room light. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Chen, Fu-chao; Zhu, Jun; Li, Bin; Yuan, Fang-jun; Wang, Lin-hai
2016-01-01
Background Mixing 5-hydroxytryptamine-3 (5-HT3) receptor antagonists with patient-controlled analgesia (PCA) solutions of tramadol has been shown to decrease the incidence of nausea and vomiting associated with the use of tramadol PCA for postoperative pain. However, such mixtures are not commercially available, and the stability of the drug combinations has not been duly studied. The study aimed to evaluate the stability of tramadol with three 5-HT3 receptor antagonists in 0.9% sodium chloride injection for PCA administration. Materials and methods Test samples were prepared by adding 1,000 mg tramadol hydrochloride, 8 mg ondansetron hydrochloride, and 6 mg granisetron hydrochloride or 5 mg tropisetron hydrochloride to 100 mL of 0.9% sodium chloride injection in polyolefin bags. The samples were prepared in triplicates, stored at either 25°C or 4°C for 14 days, and assessed using the following compatibility parameters: precipitation, cloudiness, discoloration, and pH. Chemical stability was also determined using a validated high-pressure liquid chromatography method. Results All of the mixtures were clear and colorless throughout the initial observation period. No change in the concentration of tramadol hydrochloride occurred with any of the 5-HT3 receptor antagonists during the 14 days. Similarly, little or no loss of the 5-HT3 receptor antagonists occurred over the 14-day period. Conclusion Our results suggest that mixtures of tramadol hydrochloride, ondansetron hydrochloride, granisetron hydrochloride, or tropisetron hydrochloride in 0.9% sodium chloride injection were physically and chemically stable for 14 days when stored in polyolefin bags at both 4°C and 25°C. PMID:27350741
Kim, Kyung Hyun; Jia, Baolei; Jeon, Che Ok
2017-01-01
Halobacillus halophilus , a moderately halophilic bacterium, accumulates a variety of compatible solutes including glycine betaine, glutamate, glutamine, proline, and ectoine to cope with osmotic stress. Non-targeted analysis of intracellular organic compounds using 1 H-NMR showed that a large amount of trans-4-hydroxy-L-proline (Hyp), which has not been reported as a compatible solute in H. halophilus , was accumulated in response to high NaCl salinity, suggesting that Hyp may be an important compatible solute in H. halophilus . Candidate genes encoding proline 4-hydroxylase (PH-4), which hydroxylates L-proline to generate Hyp, were retrieved from the genome of H. halophilus through domain searches based on the sequences of known PH-4 proteins. A gene, HBHAL_RS11735, which was annotated as a multidrug DMT transporter permease in GenBank, was identified as the PH-4 gene through protein expression analysis in Escherichia coli . The PH-4 gene constituted a transcriptional unit with a promoter and a rho-independent terminator, and it was distantly located from the proline biosynthetic gene cluster ( pro operon). Transcriptional analysis showed that PH-4 gene expression was NaCl concentration-dependent, and was specifically induced by chloride anion, similar to the pro operon. Accumulation of intracellular Hyp was also observed in other bacteria, suggesting that Hyp may be a widespread compatible solute in halophilic and halotolerant bacteria.
Kim, Kyung Hyun; Jia, Baolei; Jeon, Che Ok
2017-01-01
Halobacillus halophilus, a moderately halophilic bacterium, accumulates a variety of compatible solutes including glycine betaine, glutamate, glutamine, proline, and ectoine to cope with osmotic stress. Non-targeted analysis of intracellular organic compounds using 1H-NMR showed that a large amount of trans-4-hydroxy-L-proline (Hyp), which has not been reported as a compatible solute in H. halophilus, was accumulated in response to high NaCl salinity, suggesting that Hyp may be an important compatible solute in H. halophilus. Candidate genes encoding proline 4-hydroxylase (PH-4), which hydroxylates L-proline to generate Hyp, were retrieved from the genome of H. halophilus through domain searches based on the sequences of known PH-4 proteins. A gene, HBHAL_RS11735, which was annotated as a multidrug DMT transporter permease in GenBank, was identified as the PH-4 gene through protein expression analysis in Escherichia coli. The PH-4 gene constituted a transcriptional unit with a promoter and a rho-independent terminator, and it was distantly located from the proline biosynthetic gene cluster (pro operon). Transcriptional analysis showed that PH-4 gene expression was NaCl concentration-dependent, and was specifically induced by chloride anion, similar to the pro operon. Accumulation of intracellular Hyp was also observed in other bacteria, suggesting that Hyp may be a widespread compatible solute in halophilic and halotolerant bacteria. PMID:29104571
NASA Astrophysics Data System (ADS)
Chen, J.; Nie, X. A.; Jiang, J. C.; Zhou, Y. H.
2018-01-01
A natural plasticizer cardanol derivatives glycidyl ether (CGE) was synthesized and employed as a plasticizer for the poly(vinyl chloride). The effect of CGE on thermal degradation of PVC films and its plasticizing mechanism were firstly reported. The molecular structure of CGE was characterized with Fourier transform infrared spectroscopy (FTIR). Thermal properties, degradation properties and compatibility of the PVC films were investigated by Differential scanning calorimeter analysis (DSC), Thermogravimetric analysis (TGA) and FTIR, respectively. Compared with the commercial plasticizers dioctylphthalate (DOP), CGE can endow PVC film with a decrease of 4.31 °C in glass transition temperature (Tg), an increase of 24.01 °C and 25.53 °C in 10% weight loss (T 10) and 50% weight loss (T 50) respectively, and a higher activetion energy of thermal degradation (Ea ).
[Magnetic resonance compatibility research for coronary mental stents].
Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren
2015-01-01
The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.
Advanced Valve Technology. Volume 2. Materials Compatibility and Liquid Propellant Study
1967-11-01
hydrogen fluoride and hydrogen chloride, which are formed by the reaction of chlorine trifluoride with water. Aluminum alloys, 18-8 stainless steels... CHLORINE TRIFLUORIDE (CTF) (ClF3) 1-68 CHLORINE PENTAFLUORIDE 1-72 OXYGEN DIFLUORIDE (OF2) 1-74 PERCHLORYL FLUORIDE (PF) (FC103 or C103F) 1-79...enclosures refer to the Propellant Rating Chart, Page 1-11. 1-67 SPACE STORABLE PROPELLANTS (Continued) OXIDIZERS CHLORINE TRIFLUORIDE (CTF) (CIF 3
Soucek, David J; Mount, David R; Dickinson, Amy; Hockett, J Russell; McEwen, Abigail R
2015-10-01
The strain of Hyalella azteca (Saussure: Amphipoda) commonly used for aquatic toxicity testing in the United States has been shown to perform poorly in some standardized reconstituted waters frequently used for other test species. In 10-d and 42-d experiments, the growth and reproduction of the US laboratory strain of H. azteca was shown to vary strongly with chloride concentration in the test water, with declining performance observed below 15 mg/L to 20 mg/L. In contrast to the chloride-dependent performance of the US laboratory strain of H. azteca, growth of a genetically distinct strain of H. azteca obtained from an Environment Canada laboratory in Burlington, Ontario, Canada, was not influenced by chloride concentration. In acute toxicity tests with the US laboratory strain of H. azteca, the acute toxicity of sodium nitrate increased with decreasing chloride in a pattern similar not only to that observed for control growth, but also to previous acute toxicity testing with sodium sulfate. Subsequent testing with the Burlington strain showed no significant relationship between chloride concentration and the acute toxicity of sodium nitrate or sodium sulfate. These findings suggest that the chloride-dependent toxicity shown for the US laboratory strain may be an unusual feature of that strain and perhaps not broadly representative of aquatic organisms as a whole. © 2015 SETAC.
Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis.
Collaco, Joseph M; Blackman, Scott M; Raraigh, Karen S; Corvol, Harriet; Rommens, Johanna M; Pace, Rhonda G; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R; Strug, Lisa J; Knowles, Michael R; Cutting, Garry R
2016-12-01
Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H 2 = 0; 95% confidence interval, 0.0-0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker for assessing response to therapies directed at mutant CFTR.
Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis
Blackman, Scott M.; Raraigh, Karen S.; Corvol, Harriet; Rommens, Johanna M.; Pace, Rhonda G.; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R.; Strug, Lisa J.; Knowles, Michael R.; Cutting, Garry R.
2016-01-01
Rationale: Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. Objectives: To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. Methods: A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Measurements and Main Results: Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H2 = 0; 95% confidence interval, 0.0–0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Conclusions: Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker for assessing response to therapies directed at mutant CFTR. PMID:27258095
Fang, Bao-xia; Li, Peng; Shi, Xiao-ya; Chen, Fu-chao; Wang, Lin-hai
2016-01-01
Abstract The administration of drugs by patient-controlled analgesia (PCA) is routinely practiced for the management of postoperative pain. It is common for 2 or more drugs to be combined in PCA solutions. The combination of analgesics and antiemetic agents is frequently required. Unfortunately, the compatibility and stability of lornoxicam and antiemetic agents, such as droperidol, ondansetrone, granisetron, and tropisetron, has not been determined. The aim of this study was to evaluate the compatibility and stability of solutions containing lornoxicam with the 4 antiemetic agents in combination for PCA administration. In our study, test samples were prepared in triplicate by adding 40 mg lornoxicam and 5 mg droperidol, 8 mg ondansetron, 6 mg granisetron, or 5 mg tropisetron to 100-mL polyolefin bags of sodium chloride 0.9% and stored at 25 °C. The analgesic mixture samples were visually inspected for precipitation, cloudiness, and discoloration at each sampling interval. Drug concentrations were determined using high-performance liquid chromatographic (HPLC) analysis. No loss of lornoxicam occurred with any of the 4 antiemetic agents tested for up to 48 hours. However, the contents of droperidol, ondansetron, granisetron, and tropisetron were significant loss >48 hours. After storage of 4.0 to 48.0 hours, the presence of a slight precipitate was observed in all the injection combinations. The results indicate that combinations of lornoxicam with droperidol, ondansetrone, granisetron, or tropisetron in infusion solution during simulated intravenous PCA administration were incompatibility when stored protected from light at 25 °C. PMID:27336868
Influence of Sodium Chloride on Growth of Neisseria meningitidis
Mitzel, John R.; Hunter, Jack A.; Beam, Walter E.
1972-01-01
Nasopharyngeal isolates of Neisseria meningitidis were tested for growth on nutrient agar with and without the addition of 0.8% sodium chloride. Of the 822 strains tested, 1.3% grew on the salt-free medium, and 74.1% grew on the medium supplemented with sodium chloride. PMID:4626905
Millar, A M; O'Brien, L M
1998-05-01
Reports have suggested that when sodium chloride injections from a plastic ampoule are used during the preparation of 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3), the radiochemical purity of the final product might be reduced. A study was therefore undertaken to examine the effect of sodium chloride injections from five manufacturers on the radiochemical purity and stability of 99Tcm-MAG3. One sodium chloride injection was supplied in a glass vial, three in plastic ampoules and one in a plastic infusion bag. Three batches of sodium chloride injections from each manufacturer were tested. The radiopharmaceutical was prepared at a radioactive concentration of 1.1 GBq in 10 ml according to the instructions of the manufacturer of TechneScan MAG3. Analysis of radiochemical purity was performed by high-performance liquid chromatography immediately after preparation and 6 h later. Using 95% as the minimum acceptable radiochemical purity, all the products were satisfactory over the 6 h test period. No manufacturer's sodium chloride injection was found to have a statistically significant effect on the radiochemical purity. Based on the 15 batches of sodium chloride injection tested, this study cannot confirm that sodium chloride injections from a plastic container affect the radiochemical purity of 99Tcm-MAG3. However, in view of the known sensitivity of some 99Tcm radiopharmaceuticals to external influences, it is probably good practice to test radiochemical purity when new batches of ancillary materials, such as sodium chloride injections, are introduced.
Evaporation behavior of lithium, potassium, uranium and rare earth chlorides in pyroprocessing
NASA Astrophysics Data System (ADS)
Jang, Junhyuk; Kim, Tackjin; Park, Sungbin; Kim, Gha-Young; Kim, Sihyoung; Lee, Sungjai
2017-12-01
The evaporation behaviors of Li, K, U, and rare earth (RE) chlorides were examined for the cathode process in pyroprocessing. The evaporation temperatures of the chlorides were evaluated in vacuum by measuring the weight decrease. In addition, an evaporation test up to 1473 K of the cathode process using a surrogate mixture of uranium and chlorides was conducted. It was found that LiCl evaporated more readily than the other chlorides. The weight of LiCl was rapidly decreased at temperatures above 981 K, while that of KCl was decreased above 1035 K, indicating the evaporation. UCl3 evaporated at temperatures above 1103 K. RE chlorides showed a similar evaporation behavior, evaporating first at 1158 K then rapidly evaporating at temperatures above 1230 K. Thus, the order of evaporation with increasing temperature was found to be LiCl < KCl < UCl3 < RE chlorides, with different RE chlorides evaporating at similar temperature. The surrogate test confirmed the observed evaporation trend of the chlorides during the cathode process, and revealed that the contamination of uranium remains by the back-reaction of RE chlorides is negligible.
Inhibitory effects of selected Turkish spices and oregano components on some foodborne fungi.
Akgül, A; Kivanç, M
1988-05-01
The inhibitory effects of 10 selected Turkish spices, oregano essential oil, thymol and carvacrol towards growth of 9 foodborne fungi were investigated in culture media with pH 3.5 and 5.5. The antifungal effects of sodium chloride, sorbic acid and sodium benzoate and the combined use of oregano with sodium chloride were also tested under the same conditions for comparison. Of the spices tested, only sodium chloride were also tested under the same conditions for comparison. Of the spices tested, only oregano at 1.0, 1.5, 2.0% (w/v) levels showed effect on all fungi. 8% (w/v) sodium chloride was less effective than oregano. Oregano essential oil, thymol or carvacrol at concentrations of 0.025% and 0.05% completely inhibited the growth of all fungi, showing greater inhibition than sorbic acid at the same concentrations. The combined use of oregano and sodium chloride exhibited a synergistic antifungal effect.
Apparatus for Sizing and Rewinding Graphite Fibers
NASA Technical Reports Server (NTRS)
Wilson, M. L.; Stanfield, C. E.
1986-01-01
Equipment ideally suited for research and development of new sizing solutions. Designed expecially for applying thermoplastic sizing solutions to graphite tow consisting of 3,000 to 12,000 filaments per tow, but accommodates other solutions, filament counts, and materials other than graphite. Closed system containing highly volatile methylene chloride vapors. Also ventilation system directly over resin reservoir. Concept used to apply sizing compounds on fiber tows or yarn-type reinforcement materials used in composite technology. Sizing solutions consist of compounds compatible with thermosets as well as thermoplastics.
Joseph, Olufunmilayo O.; Loto, Cleophas A.; Sivaprasad, Seetharaman; Ajayi, John A.; Tarafder, Soumitra
2016-01-01
In this study, micro-alloyed steel (MAS) material normally used in the production of auto parts has been immersed in an E80 simulated fuel grade ethanol (SFGE) environment and its degradation mechanism in the presence of sodium chloride (NaCl) was evaluated. Corrosion behavior was determined through mass loss tests and electrochemical measurements with respect to a reference test in the absence of NaCl. Fracture behavior was determined via J-integral tests with three-point bend specimens at an ambient temperature of 27 °C. The mass loss of MAS increased in E80 with NaCl up to a concentration of 32 mg/L; beyond that threshold, the effect of increasing chloride was insignificant. MAS did not demonstrate distinct passivation behavior, as well as pitting potential with anodic polarization, in the range of the ethanol-chloride ratio. Chloride caused pitting in MAS. The fracture resistance of MAS reduced in E80 with increasing chloride. Crack tip blunting decreased with increasing chloride, thus accounting for the reduction in fracture toughness. PMID:28773601
Phosphates behaviours in conversion of FP chlorides
NASA Astrophysics Data System (ADS)
Amamoto, I.; Kofuji, H.; Myochin, M.; Takasaki, Y.; Terai, T.
2009-06-01
The spent electrolyte of the pyroprocessing by metal electrorefining method should be considered for recycling after removal of fission products (FP) such as, alkali metals (AL), alkaline earth metals (ALE), and/or rare earth elements (REE), to reduce the volume of high-level radioactive waste. Among the various methods suggested for this purpose is precipitation by converting FP from chlorides to phosphates. Authors have been carrying out the theoretical analysis and experiment showing the behaviours of phosphate precipitates so as to estimate the feasibility of this method. From acquired results, it was found that AL except lithium and ALE are unlikely to form phosphate precipitates. However their conversion behaviours including REE were compatible with the theoretical analysis; in the case of LaPO 4 as one of the REE precipitates, submicron-size particles could be observed while that of Li 3PO 4 was larger; the precipitates were apt to grow larger at higher temperature; etc.
The Antifungal Activity of Functionalized Chitin Nanocrystals in Poly (Lactid Acid) Films
Salaberria, Asier M.; H. Diaz, Rene; Andrés, María A.; Fernandes, Susana C.M.; Labidi, Jalel
2017-01-01
As, in the market, poly (lactic acid) (PLA) is the most used polymer as an alternative to conventional plastics, and as functionalized chitin nanocrystals (CHNC) can provide structural and bioactive properties, their combination sounds promising in the preparation of functional nanocomposite films for sustainable packaging. Chitin nanocrystals were successfully modified via acylation using anhydride acetic and dodecanoyl chloride acid to improve their compatibility with the matrix, PLA. The nanocomposite films were prepared by extrusion/compression approach using different concentrations of both sets of functionalized CHNC. This investigation brings forward that both sets of modified CHNC act as functional agents, i.e., they slightly improved the hydrophobic character of the PLA nanocomposite films, and, very importantly, they also enhanced their antifungal activity. Nonetheless, the nanocomposite films prepared with the CHNC modified with dodecanoyl chloride acid presented the best properties. PMID:28772902
Giovannelli, D; Abballe, F
2005-08-26
A method has been developed which allows simultaneous determination of three linear alkyl trimethylammonium salts. Dodecyltrimethylammonium chloride, tetradecyltrimethylammonium bromide and hexadecyltrimethylammonium chloride are widely used as main active ingredients of lysing reagents for blood cell analyzers which perform white blood cells differential determination into two or more sub-populations by impedance analysis. The ion-pair on styrene-divinyl benzene chromatographic phase looks like a suitable, reliable and long term stable tool for separation of such quaternary compounds. The detection based on suppressed conductivity was chosen because of the lack of significance chromophores. A micromembrane suppressor device compatible with high solvent concentration (up to 80%) was used in order to minimize the conductivity background before the detection. In the present work we show how the chemical post column derivatization makes the alkyl chain detectable also by UV direct detection at 210 nm.
Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra
2015-01-01
The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.
Clausen, Lauge Peter Westergaard; Broholm, Mette Martina; Gosewinkel, Ulrich; Trapp, Stefan
2017-08-01
Trichloroethylene (TCE) is a widespread soil and groundwater pollutant and clean-up is often problematic and expensive. Phytoremediation may be a cost-effective solution at some sites. This study investigates TCE degradation by willows (S. viminalis) and willows inoculated with three strains of B. cepacia (301C, PR1-31 and VM1330-pTOM), using chloride formation as an indicator of dehalogenation. Willows were grown in non-sterile, hydroponic conditions for 3 weeks in chloride-free nutrient solution spiked with TCE. TCE was added weekly due to rapid loss by volatilization. Chloride and TCE in solution were measured every 2-3 days and chloride and metabolite concentrations in plants were measured at test termination. Based on transpiration, no tree toxicity of TCE exposure was observed. However, trees grown in chloride-free solution showed severely inhibited transpiration. No or very little chloride was formed during the test, and levels of chloride in TCE-exposed trees were not elevated. Chloride concentrations in chloride containing TCE-free nutrient solution doubled within 23 days, indicating active exclusion of chloride by root cell membranes. Only traces of TCE-metabolites were detected in plant tissue. We conclude that TCE is not, or to a limited extent (less than 3%), aerobically degraded by the willow trees. The three strains of B. cepacia did not enhance TCE mineralization. Future successful application of rhizo- and phytodegradation of TCE requires measures to be taken to improve the degradation rates.
Relationship between sweat chloride, sodium, and age in clinically obtained samples.
Traeger, Nadav; Shi, Qiuhu; Dozor, Allen J
2014-01-01
The relationship between sweat electrolytes and age is uncertain, as is the value of measuring sodium or the chloride:sodium ratio. 13,785 sweat tests performed over 23 years at one center through the Macroduct collection in clinically obtained samples were analyzed. Sweat chloride tended to decrease over the first year of life, slowly increase until the fourth decade, then either level off or slightly decrease. In children, sweat sodium overlapped between those with positive and negative sweat tests, but not in adults. If the sweat test was positive, there was a higher likelihood of having a chloride:sodium ratio >1, but most subjects with a ratio >1 did not have CF. Sweat chloride and sodium vary with age. Measurement of sweat sodium did not add discriminatory value. The proportion of subjects with a chloride:sodium ratio >1, with or without CF, varied greatly between age ranges. © 2013. Published by Elsevier B.V. on behalf of European Cystic Fibrosis Society. All rights reserved.
Mitigation of corrosion attack on carbon steel coated cermet alloy in different anion contents
NASA Astrophysics Data System (ADS)
Khalid, Muhamad Azrin Mohd; Ismail, Azzura
2017-12-01
This research study evaluated the corrosion mechanism attack on carbon steel coated with cermet alloys (WC-9% Ni) in seawater at different sulphate-to-chloride ratios. The four different sulphate-to-chloride ratios were synthesised with the same seawater salinity of 3.5 % and same pH of real seawater. The corrosion tests involved immersion and electrochemical tests. The immersion test is used to determine the cermet coating ability to withstand the corrosion attack based on different ratios of anions present in the seawater at different periods of immersion. The corrosion attack was characterized by optical and Scanning Electron Microscopy (SEM). The aggressive anions present in the seawater influenced the corrosion attack on the cermet coating. For immersion test, results revealed that increasing sulphate more than chloride, increased the weight loss of cermets. The electrochemistry analysis showed that the passive layer forms on cermet coating prevented the material from further corrosion attack. However, due to its porosity, the passive layer collapsed and exposed the material for other corrosion reaction. For electrochemical test, the result shows that the solution with sulphate-to-chloride ratio of 0.14 (real seawater) has the highest corrosion current and Open Circuit Potential (OCP) compared to other solutions (different sulphate-to-chloride ratio). In conclusion, sulfate and chloride show their competition to attack the cermet coating on carbon steel and the higher the amount of chloride present in seawater, the higher the corrosion rate and pits formed on the cermet coating.
Supplanting the rapid chloride permeability test with a quick measurement of concrete conductivity.
DOT National Transportation Integrated Search
2005-01-01
The rapid chloride permeability test (RCPT) (AASHTO T 277, ASTM C 1202) is increasingly being used as an acceptance test for concrete constructions in the transportation industry. As more and more projects are subject to such testing, the capabilitie...
Qualitative Determination of Nitrate with Triphenylbenzylphosphonium Chloride.
ERIC Educational Resources Information Center
Berry, Donna A.; Cole, Jerry J.
1984-01-01
Discusses two procedures for the identification of nitrate, the standard test ("Brown Ring" test) and a new procedure using triphenylbenzylphosphonium chloride (TPBPC). Effectiveness of both procedures is compared, with the TPBPC test proving to be more sensitive and accurate. (JM)
NASA Astrophysics Data System (ADS)
Fayomi, O. S. I.; Anawe, PAL; Ayoola, A. A.; Joseph, O. O.
2018-05-01
In this study, aluminium material normally used in the underlie ship was immersed in simulated sodium chloride environment and its degradation properties was evaluated. Investigation of corrosion rate and mass weight loss through gravimetric tests measurements showed that less mass loss was recorded for tests in sodium chloride with 3-(2'-chloro-6' fluorophenyl) and lowest corrosion rate values were found at 10%. On the other hand, the mass loss deteriorated in all 3-(2'-chloro-6' fluorophenyl) with less uniform corrosion. The existence of chloride dissolved the interfacial surface layer resulting into pit initiation and growth. It is found that corrosion degradation of aluminum is dependent on chloride and inhibitive concentration.
Sweating the small stuff: adequacy and accuracy in sweat chloride determination.
DeMarco, Mari L; Dietzen, Dennis J; Brown, Sarah M
2015-04-01
Sweat chloride testing is the gold standard for diagnosis of cystic fibrosis (CF). Our objectives were to: 1) describe variables that determine sweat rate; 2) determine the analytic and diagnostic capacity of sweat chloride analysis across the range of observed sweat rates; and 3) determine the biologic variability of sweat chloride concentration. A retrospective analysis was performed using data from all sweat chloride tests performed at St. Louis Children's Hospital over a 21-month period. A total of 1397 sweat chloride tests (1155 sufficient [≥75 mg], 242 insufficient [<75 mg]), were performed on 904 individuals. The sweat weight collected from forearms was statistically greater than that collected from legs. There was a negligible correlation between sweat weight and chloride concentration (r=-0.06). The mean individual biologic CV calculated from individuals with two or more sweat collections ≥75 mg was 13.1% (95% CI: 11.3-14.9%; range 0-88%) yielding a reference change value of 36%. Using 60 mmol/L as the diagnostic chloride cutoff, 100% of CF cases were detected whether a minimum sweat weight of 75, 40, or 20 mg was required. 1) Collection of sweat from forearms is preferable to upper legs, particularly in very young infants; 2) sweat chloride concentrations are not highly dependent upon sweat rate; 3) a change in sweat chloride concentration exceeding 36% may be considered a clinically significant response to cystic fibrosis transmembrane receptor targeted therapy, and 4) sweat collections of less than 75 mg provide clinically accurate information. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Sweat chloride concentrations in children with Idiopathic Nephrotic Syndrome.
Guglani, Lokesh; Moir, Devin; Jain, Amrish
2016-01-01
Idiopathic Nephrotic Syndrome (INS) has been believed to cause a false positive elevation of sweat chloride concentrations, as measured by the sweat test. Sweat tests were done for 11 children with acute onset INS at admission and again while they were in remission, with results being compared to normal historical controls. The initial sweat chloride concentration for 10 patients was normal (mean16.7 ± 11.02 mmol/L) and 1 patient had inadequate collection. This latter patient and two others were excluded during follow-up because of diagnoses other than INS. Sweat test results for the eight INS patients during follow up remained unchanged when they were in remission (16.94 ± 7.88 mmol/L; P = 0.98; Wilcoxon Matched-Pairs Signed Rank Test). In comparing sweat chloride concentrations from INS patients to those from 20 historical control subjects, we found no significant differences (Mann-Whitney Test; initial vs. control P = 0.643; follow up vs. control P = 0.806). INS does not cause a false positive sweat test. Further studies should be done to objectively assess the conditions that have been reported to affect sweat chloride concentrations. © 2015 Wiley Periodicals, Inc.
Development of a screening system for cystic fibrosis.
Coury, A J; Fogt, E J; Norenberg, M S; Untereker, D F
1983-09-01
We have developed a simple method for detecting high concentrations of chloride in sweat from ambulatory subjects, a measurement useful in the detection of cystic fibrosis. The method is based on the standard approach of stimulating sweat generation through iontophoresis of pilocarpine nitrate into the skin, followed by collection and analysis of the sweat for chloride concentration. The sweat-stimulating reagents are contained in polymeric gel pads, which are used in conjunction with a small battery-powered stimulator. The chloride analysis is subsequently done on the stimulated site by use of a thin test patch that picks up a fixed amount of sweat and changes color if the chloride concentration is higher than a predetermined value. The successful completion of a test is indicated by a fill tab, which changes color when the appropriate amount of sweat has been picked up by the chloride test patch.
Gonçalves, Larissa Martins; Kobayakawa, Talita Guedes; Zanette, Dino; Chaimovich, Hernan; Cuccovia, Iolanda Midea
2009-03-01
The rates of oximolysis of p-nitrophenyl diphenyl phosphate (PNPDPP) by Acetophenoxime; 10-phenyl-10-hydroxyiminodecanoic acid; 4-(9-carboxynonanyl)-1-(9-carboxy-1-hydroyiminononanyl) benzene; 1-dodecyl-2-[(hydroxyimino)methyl]-pyridinium chloride (IV) and N-methylpyridinium-2-aldoxime chloride were determined in micelles of N-hexadecyl-N,N,N-trimethylammonium chloride (CTAC), N-hexadecyl-N,N-dimethylammonium propanesulfonate and dioctadecyldimethylammonium chloride (DODAC) vesicles. The effects of CTAC micelles and DODAC vesicles on the rates of oxymolysis of O,O-Diethyl O-(4-nitrophenyl) phosphate (paraoxon) by oxime IV were also determined. Analysis of micellar and vesicular effects on oximolysis of PNPDPP, using pseudophase or pseudophase with explicit consideration of ion exchange models, required the determination of the aggregate's effects on the pK(a) of oximes and on the rates of PNPDPP hydrolysis. All aggregates increased the rate of oximolysis of PNPDPP and the results were analyzed quantitatively. In particular, DODAC vesicles catalyzed the reaction and increased the rate of oximolysis of PNPDPP by IV several million fold at pH's compatible with pharmaceutical formulations. The rate increase produced by DODAC vesicles on the rate of oximolysis paraoxon by IV demonstrates the pharmaceutical potential of this system, since the substrate is used as an agricultural defensive agent and the surfactant is extensively employed in cosmetic formulations. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association
Khaleque, Himel N; Corbett, Melissa K; Ramsay, Joshua P; Kaksonen, Anna H; Boxall, Naomi J; Watkin, Elizabeth L J
2017-11-20
Successful process development for the bioleaching of mineral ores, particularly the refractory copper sulfide ore chalcopyrite, remains a challenge in regions where freshwater is scarce and source water contains high concentrations of chloride ion. In this study, a pure isolate of Acidihalobacter prosperus strain F5 was characterized for its ability to leach base metals from sulfide ores (pyrite, chalcopyrite and pentlandite) at increasing chloride ion concentrations. F5 successfully released base metals from ores including pyrite and pentlandite at up to 30gL -1 chloride ion and chalcopyrite up to 18gL -1 chloride ion. In order to understand the genetic mechanisms of tolerance to high acid, saline and heavy metal stress the genome of F5 was sequenced and analysed. As well as being the first strain of Ac. prosperus to be isolated from Australia it is also the first complete genome of the Ac. prosperus species to be sequenced. The F5 genome contains genes involved in the biosynthesis of compatible solutes and genes encoding monovalent cation/proton antiporters and heavy metal transporters which could explain its abilities to tolerate high salinity, acidity and heavy metal stress. Genome analysis also confirmed the presence of genes involved in copper tolerance. The study demonstrates the potential biotechnological applicability of Ac. prosperus strain F5 for saline water bioleaching of mineral ores. Copyright © 2017 Elsevier B.V. All rights reserved.
Chloride and sodium ion concentrations in saliva and sweat as a method to diagnose cystic fibrosis.
Gonçalves, Aline Cristina; Marson, Fernando Augusto Lima; Mendonça, Regina Maria Holanda; Bertuzzo, Carmen Sílvia; Paschoal, Ilma Aparecida; Ribeiro, José Dirceu; Ribeiro, Antônio Fernando; Levy, Carlos Emílio
2018-05-19
Cystic fibrosis diagnosis is dependent on the chloride ion concentration in the sweat test (≥60mEq/mL - recognized as the gold standard indicator for cystic fibrosis diagnosis). Moreover, the salivary glands express the CFTR protein in the same manner as sweat glands. Given this context, the objective was to verify the correlation of saliva chloride concentration and sweat chloride concentration, and between saliva sodium concentration and sweat sodium concentration, in patients with cystic fibrosis and healthy control subjects, as a tool for cystic fibrosis diagnosis. There were 160 subjects enrolled: 57/160 (35.70%) patients with cystic fibrosis and two known CFTR mutations and 103/160 (64.40%) healthy controls subjects. Saliva ion concentration was analyzed by ABL 835 Radiometer ® equipment and, sweat chloride concentration and sweat sodium concentration, respectively, by manual titration using the mercurimetric procedure of Schales & Schales and flame photometry. Statistical analysis was performed by the chi-squared test, the Mann-Whitney test, and Spearman's correlation. Alpha=0.05. Patients with cystic fibrosis showed higher values of sweat chloride concentration, sweat sodium concentration, saliva chloride concentration, and saliva sodium concentration than healthy controls subjects (p-value<0.001). The correlation between saliva chloride concentration and sweat chloride concentration showed a positive Spearman's Rho (correlation coefficient)=0.475 (95% CI=0.346 to 0.587). Also, the correlation between saliva sodium concentration and sweat sodium concentration showed a positive Spearman's Rho=0.306 (95% CI=0.158 to 0.440). Saliva chloride concentration and saliva sodium concentration are candidates to be used in cystic fibrosis diagnosis, mainly in cases where it is difficult to achieve the correct sweat amount, and/or CFTR mutation screening is difficult, and/or reference methods for sweat test are unavailable to implement or are not easily accessible by the general population. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
de Souza, Vanessa Rios; Freire, Tassyana Vieira Marques; Saraiva, Carla Gonçalves; de Deus Souza Carneiro, João; Pinheiro, Ana Carla Marques; Nunes, Cleiton Antônio
2013-08-01
Studies indicate a positive association between dietary salt intake and some diseases, which has promoted the tendency to reduce the sodium in foods. The objective of this study was to determine the equivalent amount of different sodium chloride replacements required to promote the same degree of ideal saltiness in butter and to study the sensory profile of sodium chloride and the substitutes using the analysis of Temporal Dominance of Sensations (TDS). Using the magnitude estimation method, it was determined that the potencies of potassium chloride, monosodium glutamate and potassium phosphate relative to the 1% sodium chloride in butter are 83·33, 31·59 and 33·32, respectively. Regarding the sensory profile of the tested salt substitutes, a bitter taste was perceived in the butter with potassium chloride, a sour taste was perceived in the butter with potassium phosphate and sweet and umami tastes were dominant in the butter with monosodium glutamate. Of all the salt substitutes tested calcium lactate, potassium lactate, calcium chloride and magnesium chloride were impractical to use in butter.
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2014 CFR
2014-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2013 CFR
2013-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2012 CFR
2012-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
40 CFR 62.14680 - May I conduct performance testing less often?
Code of Federal Regulations, 2011 CFR
2011-07-01
... data for at least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen..., hydrogen chloride, or opacity, you may choose to conduct performance tests for these pollutants every third... test shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or...
Weakening effect of cell permeabilizers on gram-negative bacteria causing biodeterioration.
Alakomi, H-L; Paananen, A; Suihko, M-L; Helander, I M; Saarela, M
2006-07-01
Gram-negative bacteria play an important role in the formation and stabilization of biofilm structures on stone surfaces. Therefore, the control of growth of gram-negative bacteria offers a way to diminish biodeterioration of stone materials. The effect of potential permeabilizers on the outer membrane (OM) properties of gram-negative bacteria was investigated and further characterized. In addition, efficacy of the agents in enhancing the activity of a biocide (benzalkonium chloride) was assessed. EDTA, polyethylenimine (PEI), and succimer (meso-2,3-dimercaptosuccinic) were shown to be efficient permeabilizers of the members of Pseudomonas and Stenotrophomonas genera, as indicated by an increase in the uptake of a hydrophobic probe (1-N-phenylnaphthylamine) and sensitization to hydrophobic antibiotics. Visualization of Pseudomonas cells treated with EDTA or PEI by atomic force microscopy revealed damage in the outer membrane structure. PEI especially increased the surface area and bulges of the cells. Topographic images of EDTA-treated cells were compatible with events assigned for the effect of EDTA on outer membranes, i.e., release of lipopolysaccharide and disintegration of OM structure. In addition, the effect of EDTA treatment was visualized in phase-contrast images as large areas with varying hydrophilicity on cell surfaces. In liquid culture tests, EDTA and PEI supplementation enhanced the activity of benzalkonium chloride toward the target strains. Use of permeabilizers in biocide formulations would enable the use of decreased concentrations of the active biocide ingredient, thereby providing environmentally friendlier products.
Electrical, thermal and abusive tests on lithium thionyl chloride cells
NASA Technical Reports Server (NTRS)
Frank, H. A.
1980-01-01
Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.
Electrical, thermal and abusive tests on lithium thionyl chloride cells
NASA Astrophysics Data System (ADS)
Frank, H. A.
1980-04-01
Electrical characterizations, thermal characterizations, and outer limits tests of lithium thionyl chloride cells are discussed. Graphs of energy density vs power density and heat rate vs time are presented along with results of forced reversal and high rate discharge tests.
Reid, Kendra R; Kennedy, Lonnie J; Crick, Eric W; Conte, Eric D
2002-10-25
Presented is a solid-phase extraction sorbent material composed of cationic alkyltrimethylammonium surfactants attached to a strong cation-exchange resin via ion-exchange. The original hydrophilic cation-exchange resin is made hydrophobic by covering the surface with alkyl chains from the hydrophobic portion of the surfactant. The sorbent material now has a better ability to extract hydrophobic molecules from aqueous samples. The entire stationary phase (alkyltrimethylammonium surfactant) is removed along with the analyte during the elution step. The elution step requires a mild elution solvent consisting of 0.25 M Mg2+ in a 50% 2-propanol solution. The main advantage of using a removable stationary phase is that traditionally utilized toxic elution solvents such as methylene chloride, which are necessary to efficiently release strongly hydrophobic species from SPE stationary phases, may now be avoided. Also, the final extract is directly compatible with reversed-phase liquid chromatography. The performance of this procedure is presented using pyrene as a test molecule.
NASA Astrophysics Data System (ADS)
Chang, Hee Jung; Lu, Xiaochuan; Bonnett, Jeff F.; Canfield, Nathan L.; Son, Sori; Park, Yoon-Cheol; Jung, Keeyoung; Sprenkle, Vincent L.; Li, Guosheng
2017-04-01
Developing advanced and reliable electrical energy storage systems is critical to fulfill global energy demands and stimulate the growth of renewable energy resources. Sodium metal halide batteries have been under serious consideration as a low cost alternative energy storage device for stationary energy storage systems. Yet, there are number of challenges to overcome for the successful market penetration, such as high operating temperature and hermetic sealing of batteries that trigger an expensive manufacturing process. Here we demonstrate simple, economical and practical sealing technologies for Na-NiCl2 batteries operated at an intermediate temperature of 190 °C. Conventional polymers are implemented in planar Na-NiCl2 batteries after a prescreening test, and their excellent compatibilities and durability are demonstrated by a stable performance of Na-NiCl2 battery for more than 300 cycles. The sealing methods developed in this work will be highly beneficial and feasible for prolonging battery cycle life and reducing manufacturing cost for Na-based batteries at elevated temperatures (<200 °C).
Iron chloride catalysed PCDD/F-formation: Experiments and PCDD/F-signatures.
Zhang, Mengmei; Buekens, Alfons; Ma, Siyuan; Li, Xiaodong
2018-01-01
Iron chloride is often cited as catalyst of PCDD/F-formation, together with copper chloride. Conversely, iron chloride catalysis has been less studied during de novo tests. This paper presents such de novo test data, derived from model fly ash incorporating iron (III) chloride and established over a vast range of temperature and oxygen concentration in the gas phase. Both PCDD/F-output and its signature are extensively characterised, including homologue and congener profiles. For the first time, a complete isomer-specific analysis is systematically established, for all samples. Special attention is paid to the chlorophenols route PCDD/F, to the 2,3,7,8-substituted congeners, and to their relationship and antagonism. Copyright © 2017 Elsevier Ltd. All rights reserved.
Precipitation of lamellar gold nanocrystals in molten polymers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palomba, M.; Carotenuto, G., E-mail: giancaro@unina.it
Non-aggregated lamellar gold crystals with regular shape (triangles, squares, pentagons, etc.) have been produced by thermal decomposition of gold chloride (AuCl) molecules in molten amorphous polymers (polystyrene and poly(methyl methacrylate)). Such covalent inorganic gold salt is high soluble into non-polar polymers and it thermally decomposes at temperatures compatible with the polymer thermal stability, producing gold atoms and chlorine radicals. At the end of the gold precipitation process, the polymer matrix resulted chemically modified because of the partial cross-linking process due to the gold atom formation reaction.
Quick setting water-compatible furfuryl alcohol polymer concretes
Sugama, Toshifumi; Kukacka, Lawrence E.; Horn, William H.
1982-11-30
A novel quick setting polymer concrete composite comprising a furfuryl alcohol monomer, an aggregate containing a maximum of 8% by weight water, and about 1-10% trichlorotoluene initiator and about 20-80% powdered metal salt promoter, such as zinc chloride, based on the weight of said monomer, to initiate and promote polymerization of said monomer in the presence of said aggregate, within 1 hour after mixing at a temperature of -20.degree. C. to 40.degree. C., to produce a polymer concrete having a 1 hour compressive strength greater than 2000 psi.
Marks, Michał; Glinicki, Michał A.; Gibas, Karolina
2015-01-01
The aim of the study was to generate rules for the prediction of the chloride resistance of concrete modified with high calcium fly ash using machine learning methods. The rapid chloride permeability test, according to the Nordtest Method Build 492, was used for determining the chloride ions’ penetration in concrete containing high calcium fly ash (HCFA) for partial replacement of Portland cement. The results of the performed tests were used as the training set to generate rules describing the relation between material composition and the chloride resistance. Multiple methods for rule generation were applied and compared. The rules generated by algorithm J48 from the Weka workbench provided the means for adequate classification of plain concretes and concretes modified with high calcium fly ash as materials of good, acceptable or unacceptable resistance to chloride penetration. PMID:28793740
Nanita, Sergio C; Padivitage, Nilusha L T
2013-03-20
A sample extraction and purification procedure that uses ammonium-salt-induced acetonitrile/water phase separation was developed and demonstrated to be compatible with the recently reported method for pesticide residue analysis based on fast extraction and dilution flow injection mass spectrometry (FED-FI-MS). The ammonium salts evaluated were chloride, acetate, formate, carbonate, and sulfate. A mixture of NaCl and MgSO4, salts used in the well-known QuEChERS method, was also tested for comparison. With thermal decomposition/evaporation temperature of <350°C, ammonium salts resulted in negligible ion source residual under typical electrospray conditions, leading to consistent method performance and less instrument cleaning. Although all ammonium salts tested induced acetonitrile/water phase separation, NH4Cl yielded the best performance, thus it was the preferred salting out agent. The NH4Cl salting out method was successfully coupled with FI/MS/MS and tested for fourteen pesticide active ingredients: chlorantraniliprole, cyantraniliprole, chlorimuron ethyl, oxamyl, methomyl, sulfometuron methyl, chlorsulfuron, triflusulfuron methyl, azimsulfuron, flupyrsulfuron methyl, aminocyclopyrachlor, aminocyclopyrachlor methyl, diuron and hexazinone. A validation study was conducted with nine complex matrices: sorghum, rice, grapefruit, canola, milk, eggs, beef, urine and blood plasma. The method is applicable to all analytes, except aminocyclopyrachlor. The method was deemed appropriate for quantitative analysis in 114 out of 126 analyte/matrix cases tested (applicability rate=0.90). The NH4Cl salting out extraction/cleanup allowed expansion of FI/MS/MS for analysis in food of plant and animal origin, and body fluids with increased ruggedness and sensitivity, while maintaining high-throughput (run time=30s/sample). Limits of quantitation (LOQs) of 0.01mgkg(-1) (ppm), the 'well-accepted standard' in pesticide residue analysis, were achieved in >80% of cases tested; while limits of detection (LODs) were typically in the range of 0.001-0.01mgkg(-1) (ppm). A comparison to a well-established HPLC/MS/MS method was also conducted, yielding comparable results, thus confirming the suitability of NH4Cl salting out FI/MS/MS for pesticide residue analysis. Copyright © 2013 Elsevier B.V. All rights reserved.
Saline water in southeastern New Mexico
Hiss, W.L.; Peterson, J.B.; Ramsey, T.R.
1969-01-01
Saline waters from formations of several geologic ages are being studied in a seven-county area in southeastern New Mexico and western Texas, where more than 30,000 oil and gas tests have been drilled in the past 40 years. This area of 7,500 sq. miles, which is stratigraphically complex, includes the northern and eastern margins of the Delaware Basin between the Guadalupe and Glass Mountains. Chloride-ion concentrations in water produced from rocks of various ages and depths have been mapped in Lea County, New Mexico, using machine map-plotting techniques and trend analyses. Anomalously low chloride concentrations (1,000-3,000 mg/l) were found along the western margin of the Central Basin platform in the San Andres and Capitan Limestone Formations of Permian age. These low chloride-ion concentrations may be due to preferential circulation of ground water through the more porous and permeable rocks. Data being used in the study were obtained principally from oil companies and from related service companies. The P.B.W.D.S. (Permian Basin Well Data System) scout-record magnetic-tape file was used as a framework in all computer operations. Shallow or non-oil-field water analyses acquired from state, municipal, or federal agencies were added to these data utilizing P.B.W.D.S.-compatible reference numbers and decimal latitude-longitude coordinates. Approximately 20,000 water analyses collected from over 65 sources were coded, recorded on punch cards and stored on magnetic tape for computer operations. Extensive manual and computer error checks for duplication and accuracy were made to eliminate data errors resulting from poorly located or identified samples; non-representative or contaminated samples; mistakes in coding, reproducing or key-punching; laboratory errors; and inconsistent reporting. The original 20,000 analyses considered were reduced to 6,000 representative analyses which are being used in the saline water studies. ?? 1969.
Revisiting sweat chloride test results based on recent guidelines for diagnosis of cystic fibrosis.
Pagaduan, Jayson V; Ali, Mahesheema; Dowlin, Michael; Suo, Liye; Ward, Tabitha; Ruiz, Fadel; Devaraj, Sridevi
2018-03-01
Recent sweat chloride guidelines published by the Cystic Fibrosis Foundation changed the intermediate sweat chloride concentration range from 40-59 mmol/L to 30-59 mmol/L for age > 6 months. We wanted to know how this new guideline would impact detection of cystic fibrosis among patients who previously had sweat tests done at Texas Children's Hospital. We revisited sweat chloride test results (n = 3012) in the last 5 years at Texas Children's Hospital based on the new guidelines on diagnosis of cystic fibrosis from the Cystic Fibrosis Foundation. We identified 125 patients that would be reclassified in the intermediate sweat chloride value with the new guidelines that were classified as "unlikely to have CF" in the previous guidelines. 8 (32%) patients with CFTR gene testing were positive for CFTR gene mutation(s). 4 (50%) of these patients were identified to have 2 CFTR mutations. One had variant combination that was reported to cause CF but all were diagnosed with CFTR-related metabolic syndrome. Our findings concur with the new CF diagnosis guidelines that changing the intermediate cut-off to 30-59 mmol/L sweat chloride concentration in combination with CFTR genetic analysis enhances the probability of identifying individuals that have risk of developing CF or have CF and enables for earlier therapeutic intervention.
Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.
Yu, Ningbo; Gassert, Roger; Riener, Robert
2011-07-01
Robotic and mechatronic devices that work compatibly with magnetic resonance imaging (MRI) are applied in diagnostic MRI, image-guided surgery, neurorehabilitation and neuroscience. MRI-compatible mechatronic systems must address the challenges imposed by the scanner's electromagnetic fields. We have developed objective quantitative evaluation criteria for device characteristics needed to formulate design guidelines that ensure MRI-compatibility based on safety, device functionality and image quality. The mutual interferences between an MRI system and mechatronic devices working in its vicinity are modeled and tested. For each interference, the involved components are listed, and a numerical measure for "MRI-compatibility" is proposed. These interferences are categorized into an MRI-compatibility matrix, with each element representing possible interactions between one part of the mechatronic system and one component of the electromagnetic fields. Based on this formulation, design principles for MRI-compatible mechatronic systems are proposed. Furthermore, test methods are developed to examine whether a mechatronic device indeed works without interferences within an MRI system. Finally, the proposed MRI-compatibility criteria and design guidelines have been applied to an actual design process that has been validated by the test procedures. Objective and quantitative MRI-compatibility measures for mechatronic and robotic devices have been established. Applying the proposed design principles, potential problems in safety, device functionality and image quality can be considered in the design phase to ensure that the mechatronic system will fulfill the MRI-compatibility criteria. New guidelines and test procedures for MRI instrument compatibility provide a rational basis for design and evaluation of mechatronic devices in various MRI applications. Designers can apply these criteria and use the tests, so that MRI-compatibility results can accrue to build an experiential database.
21 CFR 862.1170 - Chloride test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chloride test system. 862.1170 Section 862.1170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...
21 CFR 862.1170 - Chloride test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Chloride test system. 862.1170 Section 862.1170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...
21 CFR 862.1170 - Chloride test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Chloride test system. 862.1170 Section 862.1170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...
21 CFR 862.1170 - Chloride test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chloride test system. 862.1170 Section 862.1170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...
21 CFR 862.1170 - Chloride test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Chloride test system. 862.1170 Section 862.1170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862...
Sweat conductivity: an accurate diagnostic test for cystic fibrosis?
Mattar, Ana Claudia Veras; Leone, Claudio; Rodrigues, Joaquim Carlos; Adde, Fabíola Villac
2014-09-01
Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. Sweat conductivity is widely used although still considered a screening test. This was a prospective, cross-sectional, diagnostic research conducted at the laboratory of the Instituto da Criança of the Hospital das Clínicas, São Paulo, Brazil. Sweat chloride (quantitative pilocarpine iontophoresis) and sweat conductivity tests were simultaneously performed in patients referred for a sweat test between March 2007 and October 2008. Conductivity and chloride cut-off values used to rule out or diagnose CF were <75 and ≥90 mmol/L and <60 and ≥60 mmol/L, respectively. The ROC curve method was used to calculate the sensitivity, specificity, positive (PPV) and negative predictive value (NPV), as well as the respective 95% confidence intervals and to calculate the area under the curve for both tests. The kappa coefficient was used to evaluate agreement between the tests. Both tests were performed in 738 children, and CF was ruled out in 714 subjects; the median sweat chloride and conductivity values were 11 and 25 mmol/L in these populations, respectively. Twenty-four patients who had received a diagnosis of CF presented median sweat chloride and conductivity values of 87 and 103 mmol/L, respectively. Conductivity values above 90 mmol/L had 83.3% sensitivity, 99.7% specificity, 90.9% PPV and 99.4% NPV to diagnose CF. The best conductivity cut-off value to exclude CF was <75 mmol/L. Good agreement was observed between the tests (kappa: 0.934). The sweat conductivity test yielded a high degree of diagnostic accuracy and it showed good agreement with sweat chloride. We suggest that it should play a role as a diagnostic test for CF in the near future. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Ueira-Vieira, C; Tavares, R R; Morelli, S; Pereira, B B; Silva, R P; Torres-Mariano, A R; Kerr, W E; Bonetti, A M
2013-06-20
In order to optimize preparations of bee metaphases, we tested cobalt chloride, which has been used as a metaphase inducer in other organisms, such as hamsters and fish. Four microliters of 65 mM cobalt chloride aqueous solution was topically applied to larval and pupal stages of the stingless bee Melipona scutellaris. The cerebral ganglion was removed after treatment and prepared for cytogenetic analysis. Identically manipulated untreated individuals were used as controls. The number of metaphases was increased 3-fold in treated individuals compared to controls. The micronucleus test showed no mutagenic effects of cobalt chloride on M. scutellaris cells. We concluded that cobalt chloride is a metaphase-inducing agent in M. scutellaris, thus being useful for cytogenetic analyses.
Li/BCX (thionyl chloride) battery for the NASA AN/PRC-112 survival radio
NASA Astrophysics Data System (ADS)
Ebel, Steven J.; Clark, W. D. K.; Eberhard, D. P.; Darcy, Eric C.
1992-02-01
As part of the NASA contingency planning related to aborting a launch after liftoff, an emergency radio is required for use by the crew when they return to Earth at some unplanned location. The power source for the radio must be able to satisfy the performance requirements for the radio's mission as well as be compatible with in-cabin storage in the space shuttle. The radio needs a base load power of about 1 W with capability to handle power spikes greater then 6.5 W. A slightly enlarged battery pack using the Li/BCX chemistry in C-size cells was developed that meets these power levels and extends the operational life of the radio by over a factor of four compared to its operation using a Li/SO2 cell battery pack. In addition, the cells meet the requirements for the Li/BCX cells used for extra-vehicular activities by the crew of the shuttle. One of the major qualifying tests is the ability of the cells to withstand exposure to high temperature (149 C) without leaking. Electrical performance and thermal abuse test data will be presented for the cells.
Li/BCX (thionyl chloride) battery for the NASA AN/PRC-112 survival radio
NASA Technical Reports Server (NTRS)
Ebel, Steven J.; Clark, W. D. K.; Eberhard, D. P.; Darcy, Eric C.
1992-01-01
As part of the NASA contingency planning related to aborting a launch after liftoff, an emergency radio is required for use by the crew when they return to Earth at some unplanned location. The power source for the radio must be able to satisfy the performance requirements for the radio's mission as well as be compatible with in-cabin storage in the space shuttle. The radio needs a base load power of about 1 W with capability to handle power spikes greater then 6.5 W. A slightly enlarged battery pack using the Li/BCX chemistry in C-size cells was developed that meets these power levels and extends the operational life of the radio by over a factor of four compared to its operation using a Li/SO2 cell battery pack. In addition, the cells meet the requirements for the Li/BCX cells used for extra-vehicular activities by the crew of the shuttle. One of the major qualifying tests is the ability of the cells to withstand exposure to high temperature (149 C) without leaking. Electrical performance and thermal abuse test data will be presented for the cells.
Biological variability of the sweat chloride in diagnostic sweat tests: A retrospective analysis.
Vermeulen, F; Lebecque, P; De Boeck, K; Leal, T
2017-01-01
The sweat test is the current gold standard for the diagnosis of cystic fibrosis (CF). CF is unlikely when sweat chloride (Cl sw ) is lower than 30mmol/L, Cl sw >60 is suggestive of CF, with intermediate values between 30 and 60mmol/L. To correctly interpret a sweat chloride value, the biological variability of the sweat chloride has to be known. Sweat tests performed in two centers using the classic Gibson and Cooke method were retrospectively reviewed (n=5904). Within test variability of Cl sw was measured by comparing results from right and left arm collected on the same day. Between test variability was calculated from subjects with sweat tests performed on more than one occasion. Within test variability of Cl sw calculated in 1022 subjects was low with differences between -3.2 (p5) and +3.6mmol/L (p95). Results from left and right arm were classified differently in only 3 subjects. Between test variability of Cl sw in 197 subjects was larger, with differences between -18.2mmol/L (p5) and +14.1mmol/L (p95) between repeat tests. Changes in diagnostic conclusion were seen in 55/197 subjects, the most frequent being changing from indeterminate to 'CF unlikely' range (48/102). Variability of sweat chloride is substantial, with frequent changes in diagnostic conclusion, especially in the intermediate range. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Bukiet, Frédéric; Couderc, Guillaume; Camps, Jean; Tassery, Hervé; Cuisinier, Frederic; About, Imad; Charrier, Anne; Candoni, Nadine
2012-11-01
The purposes of the present study were to (1) assess the effect of the addition of benzalkonium chloride to sodium hypochlorite on its wetting properties, contact angle, and surface energy; (2) determine the critical micellar concentration of benzalkonium chloride in sodium hypochlorite; and (3) investigate the influence of addition of benzalkonium chloride on the free chlorine level, cytotoxicity, and antiseptic properties of the mixture. Solutions of benzalkonium chloride, with concentrations ranging from 0%-1%, were mixed in 2.4% sodium hypochlorite and tested as follows. The wetting properties were investigated by measuring the contact angle of the solutions on a nondehydrated dentin surface by using the static sessile drop method. The pending drop technique was subsequently used to determine the surface energy of the solutions. The critical micellar concentration of benzalkonium chloride mixed in sodium hypochlorite was calculated from the data. When 2.4% NaOCl was mixed with benzalkonium chloride at the critical micellar concentration, 3 parameters were tested: free chloride content, cytotoxicity, and antibacterial effects against Enterococcus faecalis. The contact angle (P < .001) as well as the surface energy (P < .001) significantly decreased with increasing benzalkonium chloride concentrations. The critical micellar concentration of benzalkonium chloride in sodium hypochlorite was 0.008%. At this concentration, the addition of benzalkonium chloride had no effect on the free chlorine content, cytotoxicity, or antibacterial efficiency of the mixture. The addition of benzalkonium chloride to sodium hypochlorite at the critical micellar concentration reduced the contact angle by 51.2% and the surface energy by 53.4%, without affecting the free chloride content, cytotoxicity, or antibacterial properties of the mixture. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Nelson, H. G.
1973-01-01
The physical characteristics of stress corrosion cracking of titanium in an aqueous chloride environment are compared with those of embrittlement of titanium by a gaseous hydrogen environment in an effort to help contribute to the understanding of the possible role of hydrogen in the complex stress corrosion cracking process. Based on previous studies, the two forms of embrittlement are shown to be similar at low hydrogen pressures (100 N/sqm) but dissimilar at higher hydrogen pressures. In an effort to quantify this comparison, tests were conducted in an aqueous chloride solution using the same material and test techniques as had previously been employed in a gaseous hydrogen environment. The results of these tests strongly support models based on hydrogen as the embrittling species in an aqueous chloride environment. Further, it is shown that if hydrogen is the causal species, the effective hydrogen fugacity at the surface of titanium exposed to an aqueous chloride environment is equivalent to a molecular hydrogen pressure of approximately 10 N/sqm.
Antimicrobial activity of N-alkoxycarbonylmethyl-N-alkyl-piperidinium chlorides.
Woźniak, Edyta; Mozrzymas, Anna; Czarny, Anna; Kocieba, Maja; Rózycka-Roszak, Bozenna; Dega-Szafran, Zofia; Dulewicz, Ewa; Petryna, Magdalena
2004-01-01
The aim of the study was to assay antibacterial and antifungal activity of newly synthesised N-alkoxycarbonylmethyl-N-alkyl-piperidinium chlorides. The compounds tested were found to inhibit the growth of some Gram-negative bacteria, Gram-positive strains and some representatives of yeast-type Candida. From microbiological experiments two of the compounds tested, N-dodecyloxycarbonylmethyl-N-methyl-piperidinium chloride (3) and N-dodecyl-N-ethoxycarbonylmethyl-piperidinium chloride (6), emerged as more active than the other compounds. Since the resistance of biofilms to biocides should be noted during the design and testing of new antimicrobial agents therefore, we have analysed antibacterial properties of the most active compounds towards biofilms. Our study focused on strains of Pseudomonas aeruginosa and Staphylococcus aureus that served as main model organisms for the biofilm studies.
NASA Technical Reports Server (NTRS)
Susko, M.
1977-01-01
Electrets used to detect the chemical composition of rocket exhaust effluents were investigated. The effectiveness of electrets was assessed while comparisons were made with hydrogen chloride measuring devices from chamber and field tests, and computed results from a multilayer diffusion model. The experimental data used were obtained from 18 static test firings, chamber tests, and the Viking 1 launch to Mars. Results show that electrets have multipollutant measuring capabilities, simplicity of deployment, and speed of assessment. The electrets compared favorably with other hydrogen chloride measuring devices. The summary of the measured data from the electrets and the hydrogen chloride detectors was within the upper and lower bounds of the computed hydrogen chloride concentrations from the multilayer diffusion model.
NASA Technical Reports Server (NTRS)
Nelson, H. G.
1974-01-01
The physical characteristics of stress corrosion cracking of titanium in an aqueous chloride environment are compared with those of embrittlement of titanium by a gaseous hydrogen environment in an effort to help contribute to the understanding of the possible role of hydrogen in the complex stress corrosion cracking process. Based on previous studies, the two forms of embrittlement are shown to be similar at low hydrogen pressures (100 N/sq m) but dissimilar at higher hydrogen pressures. In an effort to quantify this comparison, tests were conducted in an aqueous chloride solution using the same material and test techniques as had previously been employed in a gaseous hydrogen environment. The results of these tests strongly support models based on hydrogen as the embrittling species in an aqueous chloride environment.
NASA Astrophysics Data System (ADS)
Zhang, Yanjuan; Gan, Tao; Li, Qian; Su, Jianmei; Lin, Ye; Wei, Yongzuo; Huang, Zuqiang; Yang, Mei
2014-09-01
Cassava stillage residue (CSR), a kind of agro-industrial plant fiber, was modified by coupling agent (CA), mechanical activation (MA), and MA-assisted CA (MACA) surface treatments, respectively. The untreated and different surface treated CSRs were used to prepare plant fibers/polymer composites (PFPC) with poly(vinyl chloride) (PVC) as polymer matrix, and the properties of these CSR/PVC composites were compared. Surface treated CSR/PVC composites possessed better mechanical properties, water resistance and dimensional stability compared with the untreated CSR/PVC composite, attributing to the improvement of interfacial properties between CSR and PVC matrix. MACA-treated CSR was the best reinforcement among four types of CSRs (untreated, MA-treated, CA-treated, and MACA-treated CSRs) because MACA treatment led to the significant improvement of dispersion, interfacial adhesion and compatibility between CSR and PVC. MACA treatment could be considered as an effective and green method for enhancing reinforcement efficiency of plant fibers and the properties of PFPC.
Thermal control system corrosion study
NASA Technical Reports Server (NTRS)
Yee, Robert; Folsom, Rolfe A.; Mucha, Phillip E.
1990-01-01
During the development of an expert system for autonomous control of the Space Station Thermal Control System (TCS), the thermal performance of the Brassboard TCS began to gradually degrade. This degradation was due to filter clogging by metallic residue. A study was initiated to determine the source of the residue and the basic cause of the corrosion. The investigation focused on the TCS design, materials compatibility, Ames operating and maintenance procedures, and chemical analysis of the residue and of the anhydrous ammonia used as the principal refrigerant. It was concluded that the corrosion mechanisms involved two processes: the reaction of water alone with large, untreated aluminum parts in a high pH environment and the presence of chlorides and chloride salts. These salts will attack the aluminum oxide layer and may enable galvanic corrosion between the aluminum and the more noble stainless steel and other metallic elements present. Recommendations are made for modifications to the system design, the materials used, and the operating and maintenance procedures, which should largely prevent the recurrence of these corrosion mechanisms.
Higher sweat chloride levels in patients with asthma: a case-control study.
Awasthi, Shally; Dixit, Pratibha; Maurya, Nutan
2015-02-01
To screen asthmatic patients by sweat chloride test to identify proportion with Cystic Fibrosis (CF); (Sweat chloride level >60 mmol/L). Also, to compare sweat chloride levels between cases of bronchial asthma and age and sex matched healthy children aged 5 mo-15 y. The present case-control study was conducted in a tertiary care hospital in India. Cases of bronchial asthma, diagnosed by GINA guideline 2008, and age matched healthy controls were included. Case to control ratio was 2:1. Sweat Chloride test was done by Pilocarpine Iontophoresis method. From April 2010 through May 2012, 216 asthmatics and 112 controls were recruited. Among asthmatics, there was no case of Cystic Fibrosis. Mean sweat chloride levels in asthmatics was 22.39 ± 8.45 mmol/L (inter-quartile range - 15-28 mmol/L) and in controls 19.55 ± 7.04 mmol/L (inter-quartile range - 15-23.5 mmol/L) (p value = 0.048). No Cystic Fibrosis case was identified among asthmatics. Mean sweat chloride levels were higher in asthmatics as compared to controls.
Embryos of estuarine grass shrimp Palaemonetes pugio have demonstrated sensitivity to various solvents and petroleum products, indicating utility for evaluating estuarine contamination. Testing was performed to establish concentration-response curves for methylene chloride, cop...
Variability of sweat chloride concentration in subjects with cystic fibrosis and G551D mutations.
Vermeulen, F; Le Camus, C; Davies, J C; Bilton, D; Milenković, D; De Boeck, K
2017-01-01
Sweat chloride concentration, a biomarker of CFTR function, is an appropriate outcome parameter in clinical trials aimed at correcting the basic CF defect. Although there is consensus on a cut-off value to diagnose CF, we have only limited information on the within subject variability of sweat chloride over time. Such information would be useful for sample size calculations in clinical trials. Therefore, we retrospectively analyzed repeated sweat chloride values obtained in patients with G551D mutation(s) assigned to placebo in an ivacaftor interventional trial. In subjects with G551D at least 12years of age, a pilocarpine sweat test using Macroduct collector was taken on both arms at 8 time points over 48weeks. We explored 1062 pilocarpine sweat test values obtained in 78 placebo patients of the VX08-770-102 trial. Mean overall sweat chloride value (all patients, all tests, n=1062) was 100.8mmol/L (SD 12.7mmol/L). Using a multilevel mixed model, the between-subject standard deviation (SD) for sweat chloride was 8.9mmol/L (95% CI 7.4-10.6) and within-subject SD was 8.1mmol/L (95% CI 7.5-8.7). Limits of repeatability for repeat measurements were -19.7 to +21.6mmol/L using values from one arm, and -13.3 to 11.8mmol/L using mean of values obtained at 4 test occasions. Sample size calculations showed that the minimal treatment effect on sweat chloride concentration that can be demonstrated for a group of 5 patients is around 15mmol/L, using a cross-over design and combinations of 4 tests for each phase of the trial. Although the sweat test is considered a robust measure, sweat chloride measurements in patients with CF and a G551D mutation had an inherent biological variability that is higher than commonly considered. Further analyses of placebo group data are crucial to learn more about the natural variability of this outcome parameter. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Weir, D C; Robertson, A S; Jones, S; Burge, P S
1989-01-01
Two cases of occupational asthma due to soft corrosive soldering fluxes used in metal jointing are described in which the diagnosis was based on work related deterioration in daily peak expiratory flow rate and positive responses in bronchial provocation tests. Both fluxes contained ammonium chloride and zinc chloride. Occupational asthma provoked by these agents has not previously been reported. PMID:2705153
DEMONSTRATION BULLETIN: CLOR-N-SOIL PCB TEST KIT L2000 PCB/CHLORIDE ANALYZER - DEXSIL CORP.
DEXSIL CORP(Environmental Test Kits)The Dexsil Corporation (Dexsil) produces two test kits that detect polychlorinated biphenyls (PCB) in soil: the Dexsil Clor-N-Soil PCB Screening Kit, and the Dexsil L2000 PCB/Chloride Analyzer. The Dexsil Clor-N-Soil PCB Screening Kit extr...
Evaluation of Durability Parameters of Concrete with Manufacture Sand and River Sand
NASA Astrophysics Data System (ADS)
Sangoju, Bhaskar; Ramesh, G.; Bharatkumar, B. H.; Ramanjaneyulu, K.
2017-09-01
Most of the states in our country have banned sand quarrying from the river beds, causing a scarcity of natural river sand for the construction sector. Manufacture sand (M-sand) is one of the alternate solutions to replace the river sand (R-sand) in concrete. The main aim of the present study is to evaluate the durability parameters of concrete with M-sand when compared to that of concrete with R-sand. Corrosion of reinforcement is one of the main deteriorating mechanisms of reinforced concrete due to the ingress of chloride ions or carbon-di-oxide. For comparative evaluation of durability parameters, accelerated tests such as Rapid Chloride Permeability Test, Rapid Chloride Migration Test and accelerated carbonation test were carried out on specimens of R-sand and M-sand. All tests were carried out after 90 days of casting. Test results reveal that the durability parameters of the concrete with M-sand in chloride induced environment is relatively better than that of concrete with R-sand and hence is recommended to use M-sand as a replacement to R-sand.
Ligand-Doped Copper Oxo-hydroxide Nanoparticles are Effective Antimicrobials
NASA Astrophysics Data System (ADS)
Bastos, Carlos A. P.; Faria, Nuno; Ivask, Angela; Bondarenko, Olesja M.; Kahru, Anne; Powell, Jonathan
2018-04-01
Bacterial resistance to antimicrobial therapies is an increasing clinical problem. This is as true for topical applications as it is for systemic therapy. Topically, copper ions may be effective and cheap antimicrobials that act through multiple pathways thereby limiting opportunities to bacteria for resistance. However, the chemistry of copper does not lend itself to facile formulations that will readily release copper ions at biologically compatible pHs. Here, we have developed nanoparticulate copper hydroxide adipate tartrate (CHAT) as a cheap, safe, and readily synthesised material that should enable antimicrobial copper ion release in an infected wound environment. First, we synthesised CHAT and showed that this had disperse aquated particle sizes of 2-5 nm and a mean zeta potential of - 40 mV. Next, when diluted into bacterial medium, CHAT demonstrated similar efficacy to copper chloride against Escherichia coli and Staphylococcus aureus, with dose-dependent activity occurring mostly around 12.5-50 mg/L of copper. Indeed, at these levels, CHAT very rapidly dissolved and, as confirmed by a bacterial copper biosensor, showed identical intracellular loading to copper ions derived from copper chloride. However, when formulated at 250 mg/L in a topically applied matrix, namely hydroxyethyl cellulose, the benefit of CHAT over copper chloride was apparent. The former yielded rapid sustained release of copper within the bactericidal range, but the copper chloride, which formed insoluble precipitates at such concentration and pH, achieved a maximum release of 10 ± 7 mg/L copper by 24 h. We provide a practical formulation for topical copper-based antimicrobial therapy. Further studies, especially in vivo, are merited.
NASA Astrophysics Data System (ADS)
Hugues, Jonathan; Andrieu, Eric; Blanc, Christine; Cloué, Jean-Marc
The electrochemical behavior of alloy 718 in a chloride-containing boric acid solution was studied to determine the influence of chloride ions as contaminants of pool water of nuclear power plants on the corrosion behavior of the alloy. Experiments were performed at 20°C and 60°C with chloride concentrations from 1.5 to 15 000 ppm, using stationary measurements i.e. OCP versus time measurements and plotting of current-potential curves. After the electrochemical tests, the samples were observed using optical microscopy. Immersion tests in chloride-containing boric acid solutions were also carried out: samples were immersed for a time as long as 17 weeks at open circuit potential and their residual mechanical properties were measured. Results showed that, whatever the chloride concentration, there was no corrosion for samples immersed at open circuit potential. However, when the samples were polarized at high potentials, intergranular corrosion might be observed in occluded zones.
TOLERANCE OF STAPHYLOCOCCUS AUREUS TO SODIUM CHLORIDE
Parfentjev, I. A.; Catelli, Anna R.
1964-01-01
Parfentjev, I. A. (Institute of Applied Biology, New York, N.Y.), and Anna R. Catelli. Tolerance of Staphylococcus aureus to sodium chloride. J. Bacteriol. 88:1–3. 1964.—The tolerance of Staphylococcus aureus to high concentrations of sodium chloride in liquid medium has been reported. We found that S. aureus grows at 37 C in Tryptose Phosphate Broth saturated with sodium chloride. No difference was noticed between possibly pathogenic and nonpathogenic strains. Under the conditions of our tests, no changes in the original properties of S. aureus strains occurred. In contrast, solutions of sodium chloride in distilled water were injurious to staphylococci and killed most of these organisms in 1 hr. Staphylococci were killed faster at 37 C than at room temperature in a solution of 0.85% sodium chloride in water. Addition of traces of Tryptose Phosphate Broth had a protective effect and prolonged the life of these organisms in physiological saline. All tests were performed at pH 7.2. PMID:14197887
Chloride: the queen of electrolytes?
Berend, Kenrick; van Hulsteijn, Leonard Hendrik; Gans, Rijk O B
2012-04-01
Channelopathies, defined as diseases that are caused by mutations in genes encoding ion channels, are associated with a wide variety of symptoms and have been documented extensively over the past decade. In contrast, despite the important role of chloride in serum, textbooks in general do not allocate chapters exclusively on hypochloremia or hyperchloremia and information on chloride other than channelopathies is scattered in the literature. To systematically review the function of chloride in man, data for this review include searches of MEDLINE, PubMed, and references from relevant articles including the search terms "chloride," "HCl," "chloride channel" "acid-base," "acidosis," "alkalosis," "anion gap" "strong anion gap" "Stewart," "base excess" and "lactate." In addition, internal medicine, critical care, nephrology and gastroenterology textbooks were evaluated on topics pertaining the assessment and management of acid-base disorders, including reference lists from journals or textbooks. Chloride is, after sodium, the most abundant electrolyte in serum, with a key role in the regulation of body fluids, electrolyte balance, the preservation of electrical neutrality, acid-base status and it is an essential component for the assessment of many pathological conditions. When assessing serum electrolytes, abnormal chloride levels alone usually signify a more serious underlying metabolic disorder, such as metabolic acidosis or alkalosis. Chloride is an important component of diagnostic tests in a wide array of clinical situations. In these cases, chloride can be tested in sweat, serum, urine and feces. Abnormalities in chloride channel expression and function in many organs can cause a range of disorders. Copyright © 2011 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
Stankovičová, Mária; Lašáková, Andrea; Medlenová, Veronika; Bezáková, Zelmíra; Cižmárik, Jozef
2014-08-01
The paper studies the kinetics of alkaline hydrolysis and stability under non-isothermal conditions of heptacainium chloride and carbisocainium chloride in the medium of aqueous-ethanolic solution of sodium hydroxide c = 0.1 mol/l and buffer solutions of values of pH 7.0 and pH 8.0. The results of the study of the kinetics of hydrolysis by means of a non-isothermal test - rate constants and activation energy values served as the basis for exact evaluation of the stability of these potential pharmaceuticals. The objective of the paper links up with the previous studies of these substances.
Kubátová, A; Fedorova, T; Skálová, I; Hyniová, L
2016-09-01
The aim of the research was to evaluate two chemical tests for non-invasive pregnancy diagnosis from urine, the Cuboni reaction and the barium chloride test, in donkeys (Equus asinus) and alpacas (Vicugna pacos). The research was carried out from April 2013 to September 2014. Urine samples were collected on five private Czech farms from 18 jennies and 12 alpaca females. Urine was collected non-invasively into plastic cups fastened on a telescopic rod, at 6-9 week intervals. In total, 60 and 54 urine samples from alpacas and jennies, respectively, were collected. The Cuboni reaction was performed by the State Veterinary Institute Prague. The barium chloride test was done with 5 ml of urine mixed together with 5 ml of 1% barium chloride solution. Results of the Cuboni reaction were strongly influenced by the reproductive status of jennies; the test was 100% successful throughout the second half of pregnancy. However, no relationship was found between the real reproductive status of alpaca females and results of the Cuboni reaction. It was concluded that the barium chloride test is not suitable for pregnancy diagnosis either in donkeys, due to significant influence of season on the results, or in alpacas, because no relationship between results of the test and the reproductive status of alpaca females was found. In conclusion, the Cuboni reaction has potential to become a standard pregnancy diagnostic method in donkeys.
Redey, Laszlo I.; Myles, Kevin M.; Vissers, Donald R.; Prakash, Jai
1996-01-01
An electrochemical cell with a positive electrode having an electrochemically active layer of at least one transition metal chloride. A negative electrode of an alkali metal and a compatible electrolyte including an alkali metal salt molten at cell operating temperature is included in the cell. The electrolyte is present at least partially as a corrugated .beta." alumina tube surrounding the negative electrode interior to the positive electrode. The ratio of the volume of liquid electrolyte to the volume of the positive electrode is in the range of from about 0.1 to about 3. A plurality of stacked electrochemical cells is disclosed each having a positive electrode, a negative electrode of an alkali metal molten at cell operating temperature, and a compatible electrolyte. The electrolyte is at least partially present as a corrugated .beta." alumina sheet separating the negative electrode and interior to the positive electrodes. The alkali metal is retained in a porous electrically conductive ceramic, and seals for sealing the junctures of the electrolyte and the adjacent electrodes at the peripheries thereof.
[Progress on suxamethonium chloride analysis].
Jiang, Ming-Zhe; Cheng, Xiang-Wei; Chu, Jian-Xin
2013-12-01
Abstract: Suxamethonium chloride is a depolarizing muscle relaxant used in general anesthesia. In overdose, it causes adverse reactions such as bradycardia, arrhythmia, cardiac arrest, and death. The article reviews the progress on testing methods of suxamethonium chloride such as infrared spectroscopy, chemical color reaction, chemical titration, enzyme electrode, chromatography and mass spectrometry.
Effect of spray drying on the properties of amylose-hexadecylammonium chloride inclusion complexes
USDA-ARS?s Scientific Manuscript database
Water soluble amylose-hexadecyl ammonium chloride complexes were prepared from high amylose corn starch and hexadecyl ammonium chloride by excess steam jet cooking. Amylose inclusion complexes were spray dried to determine the viability of spray drying as a production method. The variables tested in...
Test operations procedure (TOP) 1-2-512 electromagnetic compatibility tests
NASA Astrophysics Data System (ADS)
1995-05-01
This TOP provides guidance for the planning, execution, and reporting of grounding and bonding and electromagnetic compatibility (EMC) tests of electrical, electronic, and electrochemical equipment, subsystems, and systems.
Assessment of dynamic surface leaching of monolithic surface road materials.
Paulus, Hélène; Schick, Joachim; Poirier, Jean-Eric
2016-07-01
Construction materials have to satisfy, among others, health and environment requirements. To check the environmental compatibility of road construction materials, release of hazardous substances into water must be assessed. Literature mostly describes the leaching behaviour of recycled aggregates for potential use in base or sub-base layers of roads. But little is known about the release of soluble substances by materials mixed with binders and compacted for intended use on road surface. In the present study, we thus performed a diffusion test with sequential renewal of water during a 64 day period according to CEN/TS 16637-2 specifications, on asphalt concretes and hydraulically bound monoliths, two common surface road materials. It is shown that release of dangerous substances is limited in these hydrodynamic conditions. It was particularly true for asphalt concrete leachates where no metallic trace element, sulphate, chloride or fluoride ion could be quantified. This is because of the low hydraulic conductivity and the low polarity of the petroleum hydrocarbon binder of these specimens. For hydraulically bound materials around 20,000 mg/m(2) of sulphate diffused from the monoliths. It is one order of magnitude higher than chloride diffusion and two orders of magnitude higher than fluoride release. No metallic trace element, except small quantities of copper in the last eluate could be quantified. No adverse effect is to be expected for human and environmental health from the leachates of these compacted surface road construction materials, because all the measured parameters were below EU (Council Directive 98/83/EC) or WHO guidelines for drinking water standards. Copyright © 2016 Elsevier Ltd. All rights reserved.
Environmental stability of intercalated graphite fibers
NASA Technical Reports Server (NTRS)
Gaier, J. R.; Jaworske, D. A.
1985-01-01
Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jun; Qiu, Qiwen; Chen, Xiaochi
An experimental study is carried out with the aim to understand the interacted mechanism between carbonation and chloride aerosol attack in ordinary Portland cement (OPC) concrete. Effects of carbonation on the chloride profile, the chloride binding capacity and the chloride diffusion coefficient are evaluated. Besides, effect of chloride aerosol attack on the carbonation rate is investigated. Concrete specimens with three water-to-cement ratios (0.38, 0.47 and 0.53) are fabricated in this work. Tested results demonstrate that carbonation remarkably affects the chloride profile, reduces the chloride binding capacity, and also accelerates the rate of chloride ion diffusion of concrete. Besides, the presencemore » of chloride aerosol can lead to lower the carbonation depth and increase the pH value of carbonated concrete. Microscopic properties such as morphology, porosity, and pore size distribution for the contaminated concretes are explored by scanning electron microscope and mercury intrusion porosimetry, which provide strong evidence to these research findings.« less
Field and laboratory determination of a poly(vinyl/vinylidene chloride) additive in brick mortar.
Law, S L; Newman, J H; Ptak, F L
1990-02-01
A polymerized vinyl/vinylidene chloride additive, used in brick mortar during the 60s and 70s, is detected at the building site by the field method, which employs a commercially available chloride test strip. The field test results can then be verified by the laboratory methods. In one method, total chlorine in the mortar is determined by an oxygen-bomb method and the additive chloride is determined by difference after water-soluble chlorides have been determined on a separate sample. In the second method, the polymerized additive is extracted directly from the mortar with tetrahydrofuran (THF). The difference in weight before and after extraction of the additive gives the weight of additive in the mortar. Evaporation of the THF from the extract leaves a thin film of the polymer, which gives an infrared "fingerprint" spectrum characteristic of the additive polymer.
Compatibility Studies of Hydrogen Peroxide and a New Hypergolic Fuel Blend
NASA Technical Reports Server (NTRS)
Baldridge, Jennifer; Villegas, Yvonne
2002-01-01
Several preliminary materials compatibility studies have been conducted to determine the practicality of a new hypergolic fuel system. Hypergolic fuel ignites spontaneously as the oxidizer decomposes and releases energy in the presence of the fuel. The bipropellant system tested consists of high-test hydrogen peroxide (HTP) and a liquid fuel blend consisting of a hydrocarbon fuel, an ignition enhancer and a transition metal catalyst. In order for further testing of the new fuel blend to take place, some basic materials compatibility and HTP decomposition studies must be accomplished. The thermal decomposition rate of HTP was tested using gas evolution and isothermal microcalorimetry (IMC). Materials were analyzed for compatibility with hydrogen peroxide including a study of the affect welding has on stainless steel elemental composition and its relation to HTP decomposition. Compatibility studies of valve materials in the fuel blend were performed to determine the corrosion resistance of the materials.
Willems, Philippe; Weekx, Steven; Meskal, Anissa; Schouwers, Sofie
2017-04-01
The measurement of chloride and sodium concentrations in sweat is an important test for the diagnosis of cystic fibrosis (CF). The aim of this study was to assess the analytical variation (CV A ) and within-subject (CV I ) and between-subject (CV G ) biological variation of chloride and sodium concentrations in sweat, collected by pilocarpine iontophoresis and to determine their effect on the clinical interpretation of sweat test results. Twelve Caucasian adults (six male and six female) without symptoms suggestive for CF and with a mean age of 41 years (range 28-59) were included in the study. At least eight samples of sweat were collected from each individual by pilocarpine iontophoresis. Chloride and sodium concentrations were measured in duplicate for each sample using ion selective electrodes. After the removal of outliers, the CV A , CV I , and CV G of chloride and sodium were determined, and their impact on measurement uncertainty and reference change value were calculated. The CV A , CV I , and CV G of chloride in sweat samples were 6.5, 17.7, and 47.2%, respectively. The CV A , CV I , and CV G of sodium sweat samples were 6.0, 17.5, and 42.6%, respectively. Our study indicates that sweat chloride and sodium concentration results must be interpreted with great care. Different components of variation, particularly the biological variations, have a considerable impact on the interpretation of these results. If no pre-analytical, analytical, or post-analytical errors are suspected, repeated sweat testing to confirm first-measurement results might not be desirable.
Preparation and characterization of silver chloride nanoparticles as an antibacterial agent
NASA Astrophysics Data System (ADS)
Duong Trinh, Ngoc; Thanh Binh Nguyen, Thi; Hai Nguyen, Thanh
2015-12-01
Silver chloride nanoparticles were prepared by the precipitation reaction between silver nitrate and sodium chloride in an aqueous solution containing poly(vinyl alcohol) as a stabilizing agent. Different characteristics of the nanoparticles in suspension and in lyophilized powder such as size, morphology, chemical nature, interaction with stabilizing agent and photo-stability were investigated. Biological tests showed that the obtained silver chloride nanoparticles displayed antibacterial activities against Escherichia coli and Staphylococcus aureus.
Salvatore, Marco; Floridia, Giovanna; Amato, Annalisa; Censi, Federica; de Stefano, Maria Chiara; Ferrari, Gianluca; Tosto, Fabrizio; Taruscio, Domenica
2017-01-01
Diagnostic testing in cystic fibrosis (CF) is based on the sweat chloride test (SCT) in the context of appropriate signs and symptoms of disease and results of the gene mutation analysis. In 2014 the Istituto Superiore di Sanità (ISS) established a pilot Italian external quality assessment program for CF sweat chloride test (Italian EQA-SCT). In 2015 this activity was recognized as a third party service carried out by the ISS. The aim of the paper is to compare 2015 and 2016 results and experiences. The scheme is prospective; enrollment is voluntary and the payment of a fee is required. Participants are registered and identified by a specific Identification Number (ID) through a dedicated web-facility. Assessment covers analysis, interpretation and reporting of results. Thirteen and fifteen laboratories, participated in the 2015 and 2016 round respectively. Seven laboratories participated constantly from 2014, eleven participated both in 2015 and 2016 and four participated in 2016 for the first time. Variability in scores of chloride titration and heterogeneity in interpretation/reporting results were detected in both rounds. A total of 18 critical errors in chloride titration were made by eight different participants. Four laboratories made errors in chloride titration in 2015 but drastically improved their performance in 2016. In 2016 poor performance criteria were established and adopted. Even though results show variability in performance of laboratories, constant and mandatory participation may contribute to the improvement of performance and quality reached by laboratory.
40 CFR 60.2720 - May I conduct performance testing less often?
Code of Federal Regulations, 2010 CFR
2010-07-01
... least 3 years, and all performance tests for the pollutant (particulate matter, hydrogen chloride, or...) If your CISWI unit continues to meet the emission limitation for particulate matter, hydrogen... shows a deviation from an emission limitation for particulate matter, hydrogen chloride, or opacity, you...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lachut, J. S.
Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride didmore » not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.« less
Variation in aluminium patch test reactivity over time.
Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica
2017-11-01
Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Test data from the chloride-monitor well at Sun City Center, Hillsborough County, Florida
Sinclair, William C.
1979-01-01
A test well drilled for Southwest Florida Water Management District at Sun City Center in Hillsborough County, will serve to monitor the interface between freshwater in the aquifer and the underlying chloride water. The sulfate content of the water in the aquifer at the well site exceeds 250 mg/L below a depth of about 700 feet. Wells for domestic and public supply in the area bottom at less than 500 feet and are separated from the sulfate water by about 100 feet of poorly-permeable limestone. The freshwater-chloride water interface is quite sharp and occurs at a depth of 1,410 feet. The chloride water is similar in composition to seawater but nearly twice as saline. (Woodard-USGS).
Jang, Jae-Kyeong; Kim, Hong-Gi; Kim, Jun-Hyeong; Ryou, Jae-Suk
2018-05-14
Concrete systems exposed to deicers are damaged in physical and chemical ways. In mitigating the damage from CaCl₂ deicers, the usage of ground slag cement and MgO are investigated. Ordinary Portland cement (OPC) and slag cement are used in different proportions as the binding material, and MgO in doses of 0%, 5%, 7%, and 10% are added to the systems. After 28 days of water-curing, the specimens are immersed in 30% CaCl₂ solution by mass for 180 days. Compressive strength test, carbonation test, chloride penetration test, chloride content test, XRD analysis, and SEM-EDAX analysis are conducted to evaluate the damage effects of the deicing solution. Up to 28 days, plain specimens with increasing MgO show a decrease in compressive strength, an increase in carbonation resistance, and a decrease in chloride penetration resistance, whereas the S30- and S50- specimens show a slight increase in compressive strength, an increase in carbonation resistance, and a slight increase in chloride penetration resistance. After 180 days of immersion in deicing solution, specimens with MgO retain their compressive strength longer and show improved durability. Furthermore, the addition of MgO to concrete systems with slag cement induces the formation of magnesium silicate hydrate (M-S-H) phases.
Evaluation of several chemical disinfectants for removing zebra mussels from unionid mussels
Waller, D.L.; Fisher, S.W.
1998-01-01
We evaluated the safety and effectiveness of chemical treatments for killing veliger and juvenile stages of the zebra mussel Dreissena polymorpha attached to unionid mussels. Static toxicity tests were conducted on eight unionid mussel species with common aquaculture chemicals (benzalkonium chloride, formalin, hydrogen peroxide, calcium chloride, potassium chloride, and sodium chloride). The concentration and duration of each chemical treatment tested had previously been found to kill zebra mussel veligers and juveniles. Several species (e.g., Elliptio dilatata, Lampsilis cardium, and Lasmigona complanata) incurred less than 10% mortality in chloride salt treatments, while in other species (e.g., Obliquaria reflexa and Leptodea fragilis) mortality varied greatly among treatment regimes. Treatments with benzalkonium chloride, formalin, and hydrogen peroxide were less than 90% effective on juvenile stages of zebra mussels and, therefore, were ruled out after preliminary trials. Limited application of specific chemical treatments may be feasible for more tolerant species; however, effective disinfection of unionid shells will require the use of chemical treatment followed by a quarantine period to completely remove zebra mussel larvae and juveniles.
Zhou, Zhuang; Rajabzadeh, Saeid; Fang, Lifeng; Miyoshi, Taro; Kakihana, Yuriko; Matsuyama, Hideto
2017-08-01
Braid-reinforced hollow fiber membranes with high mechanical properties and considerable antifouling surface were prepared by blending poly(vinyl chloride) (PVC) with poly(vinyl chloride-co-poly(ethylene glycol) methyl ether methacrylate) (poly(VC-co-PEGMA)) copolymer via non-solvent induced phase separation (NIPS). The tensile strength of the braid-reinforced PVC hollow fiber membranes were significantly larger than those of previously reported various types of PVC hollow fiber membranes. The high interfacial bonding strength indicated the good compatibility between the coating materials and the surface of polyethylene terephthalate (PET)-braid. Owing to the surface segregation phenomena, the membrane surface PEGMA coverage increased upon increasing the poly(VC-co-PEGMA)/PVC blending ratio, resulting in higher hydrophilicities and bovine serum albumin (BSA) repulsion. To compare the fouling properties, membranes with similar PWPs were prepared by adjusting the dope solution composition to eliminate the effect of hydrodynamic conditions on the membrane fouling performance. The blend membranes surface exhibited considerable fouling resistance to the molecular adsorption from both BSA solution and activated sludge solution. In both cases, the flux recovered to almost 80% of the initial flux using only water backflush. Considering their great mechanical properties and antifouling resistance to activated sludge solution, these novel membranes show good potential for application in wastewater treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
Occurrence of ground waters of low hardness and of high chloride content in Lyon County, Minnesota
Rodis, Harry G.; Schneider, Robert
1960-01-01
Hardness and chloride determinations were made with field-testing kits at the time data were obtained on most of the farm wells in the county. Tests were made on wells that were reported to yield relatively soft or "salty" water.
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2013 CFR
2013-04-01
... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2012 CFR
2012-04-01
... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...
Willison, Hillary; Boyer, Treavor H
2012-05-01
Water treatment processes can cause secondary changes in water chemistry that alter finished water quality including chloride, sulfate, natural organic matter (NOM), and metal release. Hence, the goal of this research was to provide an improved understanding of the chloride-to-sulfate mass ratio (CSMR) with regards to chloride and sulfate variations at full-scale water treatment plants and corrosion potential under simulated premise plumbing conditions. Laboratory corrosion studies were conducted using Pb-Sn solder/Cu tubing galvanic cells exposed to model waters with low (approx. 5 mg/L Cl(-) and 10 mg/L SO(4)(2-)) and high (approx. 50 mg/L Cl(-) and 100 mg/L SO(4)(2-)) concentrations of chloride and sulfate at a constant CSMR of ≈ 0.5. The role of NOM during corrosion was also evaluated by changing the type of organic material. In addition, full-scale sampling was conducted to quantify the raw water variability of chloride, sulfate, and NOM concentrations and the changes to these parameters from magnetic ion exchange treatment. Test conditions with higher concentrations of chloride and sulfate released significantly more lead than the lower chloride and sulfate test waters. In addition, the source of NOM was a key factor in the amount of lead released with the model organic compounds yielding significantly less lead release than aquatic NOM. Copyright © 2012 Elsevier Ltd. All rights reserved.
Kunz, Bethany K.; Little, Edward E.
2015-01-01
Controlling fugitive dust while protecting natural resources is a challenge faced by all managers of unpaved roads. Unfortunately, road managers choosing between dust control products often have little objective environmental information to aid their decisions. To address this information gap, the U.S. Geological Survey and the U.S. Fish and Wildlife Service collaborated on a field test of three dust control products with the objectives of (a) evaluating product performance under real-world conditions, (b) verifying the environmental safety of products identified as practically nontoxic in laboratory tests, and (c) testing the feasibility of several environmental monitoring techniques for use in dust control tests. In cooperation with refuge staff and product vendors, three products (one magnesium chloride plus binder, one cellulose, and one synthetic fluid plus binder) were applied in July 2012 to replicated road sections at the Hagerman National Wildlife Refuge in Texas. These sections were monitored periodically for 12 months after application. Product performance was assessed by mobile-mounted particulate-matter meters measuring production of fugitive dust and by observations of road conditions. Environmental safety was evaluated through on-site biological observations and leaching tests with samples of treated aggregate. All products reduced dust and improved surface condition during those 12 months. Planned environmental measurements were not always compatible with day-to-day refuge management actions; this incompatibility highlighted the need for flexible biological monitoring plans. As one of the first field tests of dust suppressants that explicitly incorporated biological endpoints, this effort provides valuable information for improving field tests and for developing laboratory or semifield alternatives.
Breeding graft-compatible Douglas-fir rootstocks (Pseudotsuga menziesii (Mirb.) Franco).
D.L. Copes
1999-01-01
A study encompassing 24 years was conducted to determine if a breeding program could produce highly graft-compatible rootstocks. Twenty-seven trees of apparent high graft compatibility were selected and crossed to produce 226 control-pollinated families. Seedlings were grown, field planted, and grafted with test scions. Graft unions from field tests were evaluated...
Sweat Chloride as A Biomarker of CFTR Activity: Proof of Concept and Ivacaftor Clinical Trial Data
Accurso, Frank J.; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J.; Dong, Qunming; Ordonez, Claudia L.; Rowe, Steven M.; Clancy, John Paul; Konstan, Michael W.; Hoch, Heather E.; Heltshe, Sonya L.; Ramsey, Bonnie W.; Campbell, Preston W.; Ashlock, Melissa A.
2014-01-01
Background We examined data from a Phase 2 trial {NCT00457821 } of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with a G551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Methods Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing, and analysis was employed for the first time.. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Results Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Conclusions Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators. PMID:24660233
Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data.
Accurso, Frank J; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J; Dong, Qunming; Ordonez, Claudia L; Rowe, Steven M; Clancy, John Paul; Konstan, Michael W; Hoch, Heather E; Heltshe, Sonya L; Ramsey, Bonnie W; Campbell, Preston W; Ashlock, Melissa A
2014-03-01
We examined data from a Phase 2 trial {NCT00457821} of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with aG551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing,and analysis was employed for the first time. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators.
Hydrocarbon-fuel/combustion-chamber-liner materials compatibility
NASA Technical Reports Server (NTRS)
Gage, Mark L.
1990-01-01
Results of material compatibility experiments using hydrocarbon fuels in contact with copper-based combustion chamber liner materials are presented. Mil-Spec RP-1, n- dodecane, propane, and methane fuels were tested in contact with OFHC, NASA-Z, and ZrCu coppers. Two distinct test methods were employed. Static tests, in which copper coupons were exposed to fuel for long durations at constant temperature and pressure, provided compatibility data in a precisely controlled environment. Dynamic tests, using the Aerojet Carbothermal Test Facility, provided fuel and copper compatibility data under realistic booster engine service conditions. Tests were conducted using very pure grades of each fuel and fuels to which a contaminant, e.g., ethylene or methyl mercaptan, was added to define the role played by fuel impurities. Conclusions are reached as to degradation mechanisms and effects, methods for the elimination of these mechanisms, selection of copper alloy combustion chamber liners, and hydrocarbon fuel purchase specifications.
Yang, Yong; Liu, Zhiquan; Zhang, Tong; Zhou, Guilong; Duan, Zhiqiang; Li, Bing; Dou, Shengwei; Liang, Xiaomei; Tu, Jinxing; Shen, Jinxiong; Yi, Bin; Fu, Tingdong; Dai, Cheng; Ma, Chaozhi
2018-06-03
Self-incompatibility (SI) in plants genetically prevents self-fertilization to promote outcrossing and genetic diversity. Its hybrids in Brassica have been widely cultivated due to the propagation of SI lines by spraying a salt solution. We demonstrated that suppression of Brassica napus SI from edible salt solution treatment was ascribed to sodium chloride and independent of S haplotypes, but it did not obviously change the expression of SI - related genes. Using the isobaric tags for relative and absolute quantitation (iTRAQ) technique, we identified 885 differentially accumulated proteins (DAPs) in Brassica napus stigmas of un-pollinated (UP), pollinated with compatible pollen (PC), pollinated with incompatible pollen (PI), and pollinated with incompatible pollen after edible salt solution treatment (NA). Of the 307 DAPs in NA/UP, 134 were unique and 94 were shared only with PC/UP. In PC and NA, some salt stress protein species, such as glyoxalase I , were induced, and these protein species were likely to participate in the self-compatibility (SC) pathway. Most of the identified protein species were related to metabolic pathways, biosynthesis of secondary metabolites, ribosome, and so on. A systematic analysis implied that salt treatment-overcoming SI in B. napus was likely conferred by at least five different physiological mechanisms: (i) the use of Ca 2+ as signal molecule; (ii) loosening of the cell wall to allow pollen tube penetration; (iii) synthesis of compatibility factor protein species for pollen tube growth; (iv) depolymerization of microtubule networks to facilitate pollen tube movement; and (v) inhibition of protein degradation pathways to restrain the SI response.
The effect of lithium chloride on one-trial passive avoidance learning in rats.
Johnson, F N
1976-01-01
1 Expression of a one-trial passive avoidance learning response in rats was examined following injections of lithium chloride or sodium chloride before and after initial training and before the first day of testing. Five tests were given at daily intervals, 24 h after training being the time of the first test. 2. Lithium given before the first day of testing impaired response expression on the first and all subsequent days of testing; the rate of extinction was unaffected. 3. Given both before and immediately after initial training, lithium impaired response expression on the first day of testing but slowed down the subsequent rate of extinction, leading eventually to improved performance on the fifth day, as compared with placebo-treated control subjects. 4. The results are interpreted in the light of the hypothesis that lithium impaired the central processing of sensory information. PMID:1252666
The effect of lithium on electrolyte transport by the in situ choroid plexus of the cat.
Reed, D J; Yen, M H
1980-01-01
1. The effects of lithium on electrolyte transport were studied by using the cat choroid plexus isolated in a chamber in situ. 2. Lithium infused intravenously to produce plasma lithium concentrations up to 5 m-equiv/l. caused an increase in plasma magnesium with no effect on the concentration of magnesium in the chamber fluid. 3. When 22NaCl was infused intravenously the chamber fluid/plasma ratio of 22Na was nearly 1 in the first 30 min sample and at the steady state it was significantly greater than 1. 4. When lithium chloride (1.5 m-equiv/l.) or potassium chloride (6.6 m-equiv/l.) was added to the chamber at the start of a collection period with plasma 22Na in the steady state, the 22Na content of the chamber fluid promptly increased 118 and 68%, respectively, above the control value with no increase in secretory rate. 5. The addition of ouabain to the chamber fluid, in addition to the lithium chloride or potassium chloride, tended to stimulate or have no significant effect on 22Na uptake at a concentration of 10(-5) M and to reduce it as well as the secretory rate at 10(-3) M. 6. The date are compatible with there being two functionally separate sodium transport systems in the choroid plexus. One transports sodium accompanied by an anion and water to provide the fluid secreted into the chamber (c.s.f.) and the other operates primarily to regulate the potassium concentration of the c.s.f. by pumping potassium out in exchange for sodium. 7. Lithium can be transported by both systems to a limited extent and the presence of lithium in the c.s.f. stimulates the sodium-potassium regulating pump. PMID:7252869
Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems
NASA Astrophysics Data System (ADS)
Tsaliovich, Anatoly
Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.
Medeiros Caporale, Graciane Maria; Rodrigues da Silva, Andréa de Cássia; Peixoto, Zélia Maria Pinheiro; Chaves, Luciana Botelho; Carrieri, Maria Luiza; Vassão, Ruth Camargo
2009-01-01
The laboratory tests recommended by the World Health Organization for detection of rabies virus and evaluation of specific antibodies are performed with fluorescent antibodies against the virus, the ribonucleoproteins (RNPs), or by monoclonal antibodies. In this study, we purified the rabies virus RNPs for the production of a conjugate presenting sensibility and specificity compatible with commercial reagents. The method employed for the purification of RNPs was ultracentrifugation in cesium chloride gradient, the obtained product being used for immunizing rabbits, from which the hyperimmune sera were collected. The serum used for conjugate production was the one presenting the highest titer (1/2,560) when tested by indirect immunofluorescence. The antibodies were purified by anion exchange chromatography (QAE-Sephadex A-50),conjugated to fluorescein isothiocyanate and separated by gel filtration (Sephadex G-50). The resulting conjugate presented titers of 1/400 and 1/500 when assayed by direct immunofluorescence (DIF) and simplified fluorescence inhibition microtest, respectively. Sensibility and specificity tests were performed by DIF in 100 central nervous system samples of different animal species, presenting 100% matches when compared with the commercial reagent used as standard, independent of the conservation state of the samples. The quality reached by our conjugate will enable the standardization of this reagent for use by the laboratories performing diagnosis of rabies in Brazil, contributing to the intensification of the epidemiological vigilance and research on this disease. Copyright 2009 Wiley-Liss, Inc.
Allan, A M; Spuhler, K P; Harris, R A
1988-03-01
We demonstrated recently that low concentrations of ethanol enhanced the muscimol-stimulated chloride influx in cerebellar membranes from long sleep (LS-ethanol sensitive) mice, but had no effect on membranes from short sleep (SS-ethanol resistant) mice. The LS and SS were selected from a heterogeneous stock (HS) of mice for differential sensitivity to the hypnotic effects of ethanol as measured by the duration of the loss of the righting reflex (sleep time). In the present study, we tested 100 HS for ethanol sleep time. The mice with the shortest sleep time (HS-SS) and the mice with the longest sleep time (HS-LS) were selected and tested for the effect of ethanol and muscimol on chloride flux in cerebellum. The effects of ethanol and muscimol on both cerebellar and cortical chloride flux were also examined in rats from the 7th generation selected for differential sensitivity to the hypnotic effects of ethanol (high acute ethanol sensitive rats-HAS and low acute ethanol sensitive rats-LAS). Low concentrations of ethanol (10-30 mM) potentiated muscimol stimulation of 36Cl- uptake in both cortical and cerebellar membranes prepared from ethanol-sensitive animals (HS-LS and HAS). None of the ethanol concentrations tested altered stimulated chloride uptake in ethanol-resistant animals (HS-SS and LAS). No differences in muscimol stimulation of chloride uptake were observed between the pairs of selected lines. These findings strongly suggest that genetic differences in ethanol hypnosis are related to differences in the sensitivity of gamma-aminobutyric acid-operated chloride channels to ethanol.
Preparation of refractory cermet structures for lithium compatibility testing
NASA Technical Reports Server (NTRS)
Heestand, R. L.; Jones, R. A.; Wright, T. R.; Kizer, D. E.
1973-01-01
High-purity nitride and carbide cermets were synthesized for compatability testing in liquid lithium. A process was developed for the preparation of high-purity hafnium nitride powder, which was subsequently blended with tungsten powder or tantalum nitride and tungsten powders and fabricated into 3 in diameter billets by uniaxial hot pressing. Specimens were then cut from the billets for compatability testing. Similar processing techniques were applied to produce hafnium carbide and zirconium carbide cermets for use in the testing program. All billets produced were characterized with respect to chemistry, structure, density, and strength properties.
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2014 CFR
2014-04-01
...(vinyl fluoride) basic resins have an intrinsic viscosity of not less than 0.75 deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride... (ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers...
Fabrication and life testing of thermionic converters
NASA Technical Reports Server (NTRS)
Yang, L.; Bruce, R.
1973-01-01
An unfueled converter containing a chloride-fluoride duplex tungsten emitter of 4.78 eV vacuum work function was tested for 46,647 hours at an emitter temperature of 1973 K and an electrode power output of about 8 watts/sq cm. The test demonstrated the superior and stable performance of the (110) oriented tungsten emitter at high temperatures. Three 90 UC-10 ZrC(C/U = 1.04, tungsten additive = 4 wt %) fueled converters were fabricated and tested at an emitter temperature of 1873 K. Converter containing chloride-arc-cast duplex tungsten cladding showed temperature thermionic performance and slower rate of performance drop than converter containing chloride-fluoride duplex tungsten cladding. This is believed to be due to the superior fuel component diffusion resistance of the arc-cast tungsten substrate used in the fuel cladding. It was shown that a converter containing a carbide fueled chloride-arc-cast duplex tungsten emitter with an initial electrode power output of 6.80 watts/sq cm could still deliver an electrode power output of 6.16 watts/sq cm after 18,632 hours of operation at an emitter temperature of 1873 K.
NASA Astrophysics Data System (ADS)
Shang, Peng; Shao, Chengli; Li, Qiqing; Wu, Chifei
2018-02-01
Acrylonitrile-butadiene rubber (NBR) composites filled with Cobalt (II) Chloride (CoCl2) particles were prepared by a solvent dispersion method. Acetone was selected as solvent for NBR and CoCl2. To directly enhance the interaction between NBR and CoCl2, a coordination reaction was generated by hot pressing at 200 °C. Fourier transform infrared spectroscopy (FT-IR), ultraviolet-visible spectroscopy (UV-vis), and x-ray photoelectron spectroscopy (XPS) were employed to investigate the coordination reaction. Results showed that the coordination reaction occurred between the nitrile groups (-CN) of NBR and cobalt ions (Co2+) of CoCl2. Compared with the properties of pure NBR, the tensile strength of NBR/CoCl2 composites filled with 10 parts per hundreds of rubber (phr) CoCl2 increased 2200%. Scanning electron microscopy (SEM) indicated that the CoCl2 particles were dispersed in the NBR matrix homogeneously. The indistinguishable interface between CoCl2 particles and NBR matrix indicated good compatibility. Additionally, thermogravimetric analysis (TGA) showed that coordination reaction improved heat resistance of NBR matrix.
Davies, J A; Anderson, G K; Beveridge, T J; Clark, H C
1983-01-01
Crystal violet (hexamethyl-para-rosaniline chloride) interacts with aqueous KI-I2 during the Gram stain via a simple metathetical anion exchange to produce a chemical precipitate. There is an apparent 1:1 stoichiometry between anion (I-) and cation (hexamethyl-para-rosaniline+) during the reaction and, since the small chloride anion is replaced by the bulkier iodide, the complex formed becomes insoluble in water. It is this same precipitate which forms in the cellular substance of bacteria (both gram-positive and gram-negative types) and which initiates the Gram reaction. Potassium trichloro(eta 2-ethylene)-platinum(II), as an electronopaque marker for electron microscopy, was chemically synthesized, and it produced an anion in aqueous solution which was compatible with crystal violet for the Gram stain. It interacted with crystal violet in a similar manner as iodide to produce an insoluble complex which was chemically and physically analogous to the dye-iodide precipitate. This platinum anion therefore allows the Gram staining mechanism to be followed by electron microscopy. Images PMID:6195147
Lee, Heon; Lee, Won-June; Park, Young-Kwon; Ki, Seo Jin; Kim, Byung-Joo; Jung, Sang-Chul
2018-03-25
Iron oxide nanoparticles supported on nitrogen-doped activated carbon powder were synthesized using an innovative plasma-in-liquid method, called the liquid phase plasma (LPP) method. Nitrogen-doped carbon (NC) was prepared by a primary LPP reaction using an ammonium chloride reactant solution, and an iron oxide/NC composite (IONCC) was prepared by a secondary LPP reaction using an iron chloride reactant solution. The nitrogen component at 3.77 at. % formed uniformly over the activated carbon (AC) surface after a 1 h LPP reaction. Iron oxide nanoparticles, 40~100 nm in size, were impregnated homogeneously over the NC surface after the LPP reaction, and were identified as Fe₃O₄ by X-ray photoelectron spectroscopy and X-ray diffraction. NC and IONCCs exhibited pseudo-capacitive characteristics, and their specific capacitance and cycling stability were superior to those of bare AC. The nitrogen content on the NC surface increased the compatibility and charge transfer rate, and the composites containing iron oxide exhibited a lower equivalent series resistance.
Khudyakov, Jane I; D'haeseleer, Patrik; Borglin, Sharon E; Deangelis, Kristen M; Woo, Hannah; Lindquist, Erika A; Hazen, Terry C; Simmons, Blake A; Thelen, Michael P
2012-08-07
To process plant-based renewable biofuels, pretreatment of plant feedstock with ionic liquids has significant advantages over current methods for deconstruction of lignocellulosic feedstocks. However, ionic liquids are often toxic to the microorganisms used subsequently for biomass saccharification and fermentation. We previously isolated Enterobacter lignolyticus strain SCF1, a lignocellulolytic bacterium from tropical rain forest soil, and report here that it can grow in the presence of 0.5 M 1-ethyl-3-methylimidazolium chloride, a commonly used ionic liquid. We investigated molecular mechanisms of SCF1 ionic liquid tolerance using a combination of phenotypic growth assays, phospholipid fatty acid analysis, and RNA sequencing technologies. Potential modes of resistance to 1-ethyl-3-methylimidazolium chloride include an increase in cyclopropane fatty acids in the cell membrane, scavenging of compatible solutes, up-regulation of osmoprotectant transporters and drug efflux pumps, and down-regulation of membrane porins. These findings represent an important first step in understanding mechanisms of ionic liquid resistance in bacteria and provide a basis for engineering microbial tolerance.
Congenital Chloride Diarrhea - Novel Mutation in SLC26A3 Gene.
Bhardwaj, Swati; Pandit, Deepti; Sinha, Aditi; Hari, Pankaj; Cheong, Hae Il; Bagga, Arvind
2016-08-01
The authors report a case of congenital chloride diarrhea with molecular confirmation of diagnosis. A 10-mo-old boy presented with failure to thrive, voluminous diarrhea, dehydration, hyponatremia, hypokalemia, metabolic alkalosis and history of maternal polyhydramnios. The diagnosis of congenital chloride diarrhea was based on high fecal and low urinary chloride excretion, in addition to biochemical abnormalities. Genetic testing revealed a novel homozygous mutation in exon 4 of the SLC26A3 gene that encodes the protein regulating chloride bicarbonate absorption in distal ileum and colon. Therapy with oral fluids and electrolytes led to decrease in stool frequency and improvement in growth parameters.
Stability of Alprostadil in 0.9% Sodium Chloride Stored in Polyvinyl Chloride Containers.
McCluskey, Susan V; Kirkham, Kylian; Munson, Jessica M
2017-01-01
The stability of alprostadil diluted in 0.9% sodium chloride stored in polyvinyl chloride (VIAFLEX) containers at refrigerated temperature, protected from light, is reported. Five solutions of alprostadil 11 mcg/mL were prepared in 250 mL 0.9% sodium chloride polyvinyl chloride (PL146) containers. The final concentration of alcohol was 2%. Samples were stored under refrigeration (2°C to 8°C) with protection from light. Two containers were submitted for potency testing and analyzed in duplicate with the stability-indicating high-performance liquid chromatography assay at specific time points over 14 days. Three containers were submitted for pH and visual testing at specific time points over 14 days. Stability was defined as retention of 90% to 110% of initial alprostadil concentration, with maintenance of the original clear, colorless, and visually particulate-free solution. Study results reported retention of 90% to 110% initial alprostadil concentration at all time points through day 10. One sample exceeded 110% potency at day 14. pH values did not change appreciably over the 14 days. There were no color changes or particle formation detected in the solutions over the study period. This study concluded that during refrigerated, light-protected storage in polyvinyl chloride (VIAFLEX) containers, a commercial alcohol-containing alprostadil formulation diluted to 11 mcg/mL with 0.9% sodium chloride 250 mL was stable for 10 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Role of CFTR mutation analysis in the diagnostic algorithm for cystic fibrosis.
Ratkiewicz, Michelle; Pastore, Matthew; McCoy, Karen Sharrock; Thompson, Rohan; Hayes, Don; Sheikh, Shahid Ijaz
2017-04-01
The cystic fibrosis transmembrane conductance regulator (CFTR) gene mutation identification is being used with increased frequency to aid in the diagnosis of cystic fibrosis (CF) in those suspected with CF. Aim of this study was to identify diagnostic outcomes when CFTR mutational analysis was used in CF diagnosis. CFTR mutational analysis results were also compared with sweat chloride results. This study was done on all patients at our institution who had CFTR mutation analysis over a sevenyear period since August 2006. A total of 315 patients underwent CFTR mutational analysis. Fifty-one (16.2%) patients had two mutations identified. Among them 32 had positive sweat chloride levels (≥60 mmol/L), while seven had borderline sweat chloride levels (40-59 mmol/L). An additional 70 patients (22.3%) had only one mutation identified. Among them eight had positive sweat chloride levels, and 17 had borderline sweat chloride levels. Fifty-five patients (17.5%) without CFTR mutations had either borderline (n=45) or positive (n=10) sweat chloride results. Three patients with a CF phenotype had negative CFTR analysis but elevated sweat chloride levels. In eighty-three patients (26.4%) CFTR mutational analysis was done without corresponding sweat chloride testing. Although CFTR mutation analysis has improved the diagnostic capability for CF, its use either as the first step or the only test to diagnose CFTR dysfunction should be discouraged and CF diagnostic guidelines need to be followed.
Jang, Jae-Kyeong; Kim, Hong-Gi; Kim, Jun-Hyeong
2018-01-01
Concrete systems exposed to deicers are damaged in physical and chemical ways. In mitigating the damage from CaCl2 deicers, the usage of ground slag cement and MgO are investigated. Ordinary Portland cement (OPC) and slag cement are used in different proportions as the binding material, and MgO in doses of 0%, 5%, 7%, and 10% are added to the systems. After 28 days of water-curing, the specimens are immersed in 30% CaCl2 solution by mass for 180 days. Compressive strength test, carbonation test, chloride penetration test, chloride content test, XRD analysis, and SEM-EDAX analysis are conducted to evaluate the damage effects of the deicing solution. Up to 28 days, plain specimens with increasing MgO show a decrease in compressive strength, an increase in carbonation resistance, and a decrease in chloride penetration resistance, whereas the S30- and S50- specimens show a slight increase in compressive strength, an increase in carbonation resistance, and a slight increase in chloride penetration resistance. After 180 days of immersion in deicing solution, specimens with MgO retain their compressive strength longer and show improved durability. Furthermore, the addition of MgO to concrete systems with slag cement induces the formation of magnesium silicate hydrate (M-S-H) phases. PMID:29758008
Xu, Chen; Li, Zhiyuan; Jin, Weiliang
2013-01-01
The corrosion of reinforcements induced by chloride has resulted to be one of the most frequent causes of their premature damage. Most corrosion sensors were designed to monitor corrosion state in concrete, such as Anode-Ladder-System and Corrowatch System, which are widely used to monitor chloride ingress in marine concrete. However, the monitoring principle of these corrosion sensors is based on the macro-cell test method, so erroneous information may be obtained, especially from concrete under drying or saturated conditions due to concrete resistance taking control in macro-cell corrosion. In this paper, a fast weak polarization method to test corrosion state of reinforcements based on electrochemical polarization dynamics was proposed. Furthermore, a new corrosion sensor for monitoring the corrosion state of concrete cover was developed based on the proposed test method. The sensor was tested in cement mortar, with dry-wet cycle tests to accelerate the chloride ingress rate. The results show that the corrosion sensor can effectively monitor chloride penetration into concrete with little influence of the relative humidity in the concrete. With a reasonable corrosion sensor electrode arrangement, it seems the Ohm-drop effect measured by EIS can be ignored, which makes the tested electrochemical parameters more accurate. PMID:24084117
Xu, Chen; Li, Zhiyuan; Jin, Weiliang
2013-09-30
The corrosion of reinforcements induced by chloride has resulted to be one of the most frequent causes of their premature damage. Most corrosion sensors were designed to monitor corrosion state in concrete, such as Anode-Ladder-System and Corrowatch System, which are widely used to monitor chloride ingress in marine concrete. However, the monitoring principle of these corrosion sensors is based on the macro-cell test method, so erroneous information may be obtained, especially from concrete under drying or saturated conditions due to concrete resistance taking control in macro-cell corrosion. In this paper, a fast weak polarization method to test corrosion state of reinforcements based on electrochemical polarization dynamics was proposed. Furthermore, a new corrosion sensor for monitoring the corrosion state of concrete cover was developed based on the proposed test method. The sensor was tested in cement mortar, with dry-wet cycle tests to accelerate the chloride ingress rate. The results show that the corrosion sensor can effectively monitor chloride penetration into concrete with little influence of the relative humidity in the concrete. With a reasonable corrosion sensor electrode arrangement, it seems the Ohm-drop effect measured by EIS can be ignored, which makes the tested electrochemical parameters more accurate.
Singh, Upendra Kumar; Patel, Rajan
2018-05-25
In vitro refolding of denatured protein and the influence of the alkyl chain on the refolding of a protein were tested using long chain imidazolium chloride salts, 1-methyl-3-octylimidazolium chloride [C 8 mim][Cl], and 1-decyl-3-methylimidazolium chloride [C 10 mim][Cl]. The horse heart cytochrome c (h-cyt c) was denatured by urea and guanidinium hydrochloride (GdnHCl), as well as by base-induced denaturation at pH 13, to provide a broad overview of the overall refolding behavior. The variation in the alkyl chain of the ionic liquids (ILs) showed a profound effect on the refolding of denatured h-cyt c. The ligand-induced refolding was correlated to understand the mechanism of the conformational stability of proteins in aqueous solutions of ILs. The results showed that the long chain ILs having the [C 8 mim] + and [C 10 mim] + cations promote the refolding of alkali-denatured h-cyt c. The IL having the [C 10 mim] + cation efficiently refolded the alkali-denatured h-cyt c with the formation of the MG state, whereas the IL having the [C 8 mim] + cation, which is known to be compatible for protein stability, shows slight refolding and forms a different transition state. The lifetime results show successful refolding of alkaline-denatured h-cyt c by both of the ILs, however, more refolding was observed in the case of [C 10 mim][Cl], and this was correlated with the fast and medium lifetimes (τ 1 and τ 2 ) obtained, which show an increase accompanied by an increase in secondary structure. The hydrophobic interactions plays an important role in the refolding of chemically and alkali-denatured h-cyt c by long chain imidazolium ILs. The formation of the MG state by [C 10 mim][Cl] was also confirmed, as some regular structure exists far below the CMC of IL. The overall results suggested that the [C 10 mim] + cation bound to the unfolded h-cyt c triggers its refolding by electrostatic and hydrophobic interactions that stabilize the MG state.
42 CFR 493.863 - Standard; Compatibility testing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Compatibility testing. 493.863 Section 493.863 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
42 CFR 493.863 - Standard; Compatibility testing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Standard; Compatibility testing. 493.863 Section 493.863 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
A Combustion Products Analyzer for contingency use during thermodegradation events on spacecraft
NASA Technical Reports Server (NTRS)
Limero, Thomas; James, John T.; Beck, Steven; Cromer, Raymond
1991-01-01
This paper will describe the Combustion Products Analyzer (CPA), which is being developed under the direction of the Toxicology Laboratory at Johnson Space Center to provide necessary data on air quality in the Shuttle following a thermodegradation incident. Using separate electrochemical sensors, the CPA monitors four gases (hydrogen fluoride/carbonyl fluoride, hydrogen chloride, hydrogen cyanide, and carbon monoxide), which were selected as the most hazardous compounds likely to be released during thermodegradation of synthetic materials. Electrochemical sensors have been available for several years; the CPA sensors, which are unique because of their small size and zero-gravity compatibility, will be described in detail.
Automation of electromagnetic compatability (EMC) test facilities
NASA Technical Reports Server (NTRS)
Harrison, C. A.
1986-01-01
Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.
Chloride concentration gradients in tank-stored hydraulic fracturing fluids following flowback
Pamela J. Edwards; Linda L. Tracy; William K. Wilson
2011-01-01
A natural gas well in West Virginia was hydraulically fractured and the flowback was recovered and stored in an 18-foot-deep tank. Both in situ field test kit and laboratory measurements of electrical conductivity and chloride concentrations increased substantially with depth, although the laboratory measurements showed a greater increase. The field test kit also...
Rapid Stabilization/Polymerization of Wet Clay Soils; Literature Review
2009-01-15
known as lime, and potassium hydroxide (KOH) were found to increase shear strength, and decrease expansive properties of Diablo clay. The lime...Publication Date: 1991 Purpose of Stabilizer: Control High Swell Potential Stabilizers Tested: Lime, potassium phosphate, potassium chloride...Date: 1988 Purpose of Stabilizer: Stabilizer Stabilizers Tested: Hydroxy-aluminum, hydroxy-aluminum and potassium chloride, hydroxy-aluminum
Acquisition of lithium chloride- and radiation-induced taste aversions in hypophysectomized rats.
Rabin, B M; Hunt, W A; Lee, J
1983-03-01
The effects of hypophysectomy on the acquisition of conditioned taste aversions following injection of lithium chloride and following exposure to ionizing radiation were studied using a two-bottle preference test. Hypophysectomy did not disrupt the acquisition of a taste aversion following either treatment. The results are interpreted as: (a) suggesting that pituitary/adrenal hormones do not mediate the acquisition of a conditioned taste aversion following injections of lithium chloride or following exposure to ionizing radiation in a two-bottle preference test, and (b) consistent with other research suggesting that the involvement of pituitary/adrenal hormones in taste aversion learning may be related to the conflict induced by using a one-bottle test and not to the learning itself.
Caudri, Daan; Zitter, David; Bronsveld, Inez; Tiddens, Harm
2017-09-01
Cystic Fibrosis (CF) lung disease is characterized by a marked heterogeneity. Sweat chloride-level is a functional marker of the CF Transmembrane Regulator (CFTR) protein and could be an important predictor of later disease severity. In this retrospective analysis children from the Rotterdam CF clinic with available sweat chloride level at diagnosis and at least one routine spirometry-controlled volumetric chest CT scan in follow-up were included. CT scans were scored using the CF-CT scoring system (% of maximum). Associations between sweat chloride-levels and CF-CT scores were calculated using linear regression models, adjusting for age at sweat test and age at follow-up. Because structural lung damage develops over the course of many years, effect modification by the age at follow-up CT-scan was tested for by age-stratification. In 59 children (30 male) sweat chloride was measured at diagnosis (median age 0.5 years, range 0-13) and later chest CT performed (median age 14 years, range 6-18). Sweat chloride was associated with significantly higher CT-CT total score, bronchiectasis score, and mucus plugging score. Stratification for age at follow-up in tertiles showed this association remained only in the oldest age group (range 15-18 years). In that subgroup associations were found with all but one of the CF-CT subscores, as well as with all tested lung functions parameters. Sweat chloride-level is a significant predictor of CF lung disease severity as determined by chest CT and lung function. This association could only be demonstrated in children with follow-up to age 15 years and above. © 2017 Wiley Periodicals, Inc.
Moyer, E S; Bergman, M S
2000-08-01
The effects of intermittently loading small masses of sodium chloride aerosol on the filtration efficiency of N-95 filtering facepiece respirators was investigated. The National Institute for Occupational Safety and Health (NIOSH) certifies that N-95 respirators must provide at least 95 percent filtration efficiency against a sodium chloride aerosol challenge as per the respirator certification (42 CFR 84) test criteria. N-95 respirators are specified for protection against solid and water-based particulates (i.e., non-oil aerosols). New N-95 respirators from three different manufacturers were loaded with 5 +/- 1 mg of sodium chloride aerosol one day a week, over a period of weeks. Aerosol loading and penetration measurements were performed using the TSI 8130 Filter Tester. Respirators were stored uncovered on an office desktop outside the laboratory. To investigate environmental and temporal effects of filters being stored without sodium chloride exposure, control respirators were stored on the desk for various lengths of time before being initiated into weekly testing. For all manufacturers' respirators, the controls showed similar initial penetrations on their day of initiation (day zero) to those of the study samples on day zero. As the controls were tested weekly, they showed similar degradation rates to those of the study samples. Results show that some of the manufacturers' models had penetrations of greater than 5 percent when intermittently exposed to sodium chloride aerosol. It is concluded that intermittent, low-level sodium chloride aerosol loading of N-95 respirators has a degrading effect on filter efficiency. This reduction in filter efficiency was not accompanied by a significant increase in breathing resistance that would signal the user that the filter needs to be replaced. Furthermore, it was noted that the effect of room storage time prior to initial exposure was much less significant.
21 CFR 177.1960 - Vinyl chloride-hexene-1 copolymers.
Code of Federal Regulations, 2014 CFR
2014-04-01
... determined by any suitable analytical procedure of generally accepted applicability. (ii) Inherent viscosity... D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers,” which is...
DEVELOPMENT AND DEPLOYMENT OF VACUUM SALT DISTILLATION AT THE SAVANNAH RIVER SITE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, R.; Pak, D.; Edwards, T.
2010-10-28
The Savannah River Site has a mission to dissolve fissile materials and disposition them. The primary fissile material is plutonium dioxide (PuO{sub 2}). To support dissolution of these materials, the Savannah River National Laboratory (SRNL) designed and demonstrated a vacuum salt distillation (VSD) apparatus using both representative radioactive samples and non-radioactive simulant materials. Vacuum salt distillation, through the removal of chloride salts, increases the quantity of materials suitable for processing in the site's HB-Line Facility. Small-scale non-radioactive experiments at 900-950 C show that >99.8 wt % of the initial charge of chloride salt distilled from the sample boat with recoverymore » of >99.8 wt % of the ceric oxide (CeO{sub 2}) - the surrogate for PuO{sub 2} - as a non-chloride bearing 'product'. Small-scale radioactive testing in a glovebox demonstrated the removal of sodium chloride (NaCl) and potassium chloride (KCl) from 13 PuO{sub 2} samples. Chloride concentrations were distilled from a starting concentration of 1.8-10.8 wt % to a final concentration <500 mg/kg chloride. Initial testing of a non-radioactive, full-scale production prototype is complete. A designed experiment evaluated the impact of distillation temperature, time at temperature, vacuum, product depth, and presence of a boat cover. Significant effort has been devoted to mechanical considerations to facilitate simplified operation in a glovebox.« less
NASA Technical Reports Server (NTRS)
2009-01-01
This Interim Standard establishes requirements for evaluation, testing, and selection of materials that are intended for use in space vehicles, associated Ground Support Equipment (GSE), and facilities used during assembly, test, and flight operations. Included are requirements, criteria, and test methods for evaluating the flammability, offgassing, and compatibility of materials.
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
Raina, Manzoor A; Khan, Mosin S; Malik, Showkat A; Raina, Ab Hameed; Makhdoomi, Mudassir J; Bhat, Javed I; Mudassar, Syed
2016-12-01
Cystic Fibrosis (CF) is an autosomal recessive disorder and the incidence of this disease is undermined in Northern India. The distinguishable salty character of the sweat belonging to individuals suffering from CF makes sweat chloride estimation essential for diagnosis of CF disease. The aim of this prospective study was to elucidate the relationship of sweat chloride levels with clinical features and pattern of CF. A total of 182 patients, with clinical features of CF were included in this study for quantitative measurement of sweat chloride. Sweat stimulation and collection involved pilocarpine iontophoresis based on the Gibson and Cooks methodology. The quantitative estimation of chloride was done by Schales and Schales method with some modifications. Cystic Fibrosis Trans Membrane Conductance Regulator (CFTR) mutation status was recorded in case of patients with borderline sweat chloride levels to correlate the results and for follow-up. Out of 182 patients having clinical features consistent with CF, borderline and elevated sweat chloride levels were present in 9 (5%) and 41 (22.5%) subjects respectively. Elevated sweat chloride levels were significantly associated with wheeze, Failure To Thrive (FTT), history of CF in Siblings, product of Consanguineous Marriage (CM), digital clubbing and steatorrhoea on univariate analysis. On multivariate analysis only wheeze, FTT and steatorrhoea were found to be significantly associated with elevated sweat chloride levels (p<0.05). Among the nine borderline cases six cases were positive for at least two CFTR mutations and rest of the three cases were not having any mutation in CFTR gene. The diagnosis is often delayed and the disease is advanced in most patients at the time of diagnosis. Sweat testing is a gold standard for diagnosis of CF patients as genetic mutation profile being heterozygous and unlikely to become diagnostic test.
DOT National Transportation Integrated Search
2014-04-01
A correlation between Wavelength Dispersive X-ray Fluorescence(WDXRF) analysis of Hardened : Concrete for Chlorides and Atomic Absorption (AA) analysis (current method AASHTO T-260, procedure B) has been : found and a new method of analysis has been ...
Liver disease among polyvinyl chloride production workers.
Creech, J L; Makk, L
1975-01-31
A protocol for systematic testing of all employees of a chemical plant is presented. This factory manufactures polyvinyl chloride compounds and resins, ABS compounds and resins, and synthetic rubber. The results were reviewed, which led to the discovery of 2 additional cases of angiosarcoma and 11 cases of portal fibrosis. Two of the 11 cases were found to have developed in employees other than polyvinyl chloride production workers.
Redey, L.I.; Myles, K.M.; Vissers, D.R.; Prakash, J.
1996-07-02
An electrochemical cell is described with a positive electrode having an electrochemically active layer of at least one transition metal chloride. A negative electrode of an alkali metal and a compatible electrolyte including an alkali metal salt molten at cell operating temperature is included in the cell. The electrolyte is present at least partially as a corrugated {beta}{double_prime} alumina tube surrounding the negative electrode interior to the positive electrode. The ratio of the volume of liquid electrolyte to the volume of the positive electrode is in the range of from about 0.1 to about 3. A plurality of stacked electrochemical cells is disclosed each having a positive electrode, a negative electrode of an alkali metal molten at cell operating temperature, and a compatible electrolyte. The electrolyte is at least partially present as a corrugated {beta}{double_prime} alumina sheet separating the negative electrode and interior to the positive electrodes. The alkali metal is retained in a porous electrically conductive ceramic, and seals for sealing the junctures of the electrolyte and the adjacent electrodes at the peripheries thereof. 8 figs.
Evaluation of toxicity and biodegradability of choline chloride based deep eutectic solvents.
Radošević, Kristina; Bubalo, Marina Cvjetko; Srček, Višnje Gaurina; Grgas, Dijana; Dragičević, Tibela Landeka; Redovniković, Ivana Radojčić
2015-02-01
Deep eutectic solvents (DESs) have been dramatically expanding in popularity as a new generation of environmentally friendly solvents with possible applications in various industrial fields, but their ecological footprint has not yet been thoroughly investigated. In the present study, three choline chloride-based DESs with glucose, glycerol and oxalic acid as hydrogen bond donors were evaluated for in vitro toxicity using fish and human cell line, phytotoxicity using wheat and biodegradability using wastewater microorganisms through closed bottle test. Obtained in vitro toxicity data on cell lines indicate that choline chloride: glucose and choline chloride:glycerol possess low cytotoxicity (EC50>10 mM for both cell lines) while choline chloride:oxalic acid possess moderate cytotoxicity (EC50 value 1.64 mM and 4.19 mM for fish and human cell line, respectively). Results on phytotoxicity imply that tested DESs are non-toxic with seed germination EC50 values higher than 5000 mg L(-1). All tested DESs were classified as'readily biodegradable' based on their high levels of mineralization (68-96%). These findings indicate that DESs have a green profile and a good prospect for a wider use in the field of green technologies. Copyright © 2014 Elsevier Inc. All rights reserved.
High-temperature compatibility study of iridium (DOP-26 alloy) with graphite and plutonia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Axler, K.M.; Eash, D.T.
1987-12-01
This report outlines the materials compatibility tests conducted on DOP-26 iridium alloy and carbon. The carbon used was in the form of woven graphite as present in the impact shell used to encase plutonia in nuclear heat sources. In addition, compatibility tests of the DOP-26 alloy with plutonia are described. The reactivity observed in both systems is discussed. 4 refs., 6 figs.
Experimental Interactions of Components of Hemodialysis Units with Human Blood
Zucker, W. H.; Shinoda, B. A.; Mason, R. G.
1974-01-01
An in vitro model test system for estimation of the blood compatibility of hemodialysis membranes and tubing is described. The model test system consists of a modified hemodialysis unit and blood pump through which fresh citrated human blood is circulated. The effects of the use of different pump and tubing types upon hematologic and blood coagulation parameters are described. Preexposure of test surfaces to albumin appeared to enhance blood compatibility characteristics of the model test system, whereas preexposure to a high density lipoprotein preparation or a proteinpolysaccharide preparation was without appreciable benefit. Use of blood from subjects receiving aspirin resulted in enhanced blood compatibility in the test system as did use of heparin. Use of Warfarin or dextran did not appear to enhance blood compatibility of test surfaces under the conditions of this test system. Dialysis membranes and tubing which formed parts of the test system were examined by scanning and transmission electron microscopy in control tests and in tests for effects of proteins and antithrombotic agents. ImagesFig 5Fig 6Fig 7Fig 8Fig 9Fig 10Fig 11Fig 12Fig 13Fig 14Fig 1Fig 2Fig 3Fig 4 PMID:4825611
Transepithelial nasal potential difference (NPD) measurements in cystic fibrosis (CF).
Sands, Dorota
2013-01-01
The main underlying physiologic abnormality in cystic fibrosis (CF) is dysfunction of the CF transmembrane conductance regulator (CFTR), which results in abnormal transport of sodium and chloride across epithelial surfaces. CFTR function could be tested in vivo using measurements of nasal transepithelial potential difference (PD). Nasal measurements show characteristic features of CF epithelia, including hyperpolarized baseline readings (basal PD), excessive depolarization in response to sodium channel inhibitors, such as amiloride (ΔAmiloride), and little or no chloride (Cl-) secretion in response to isoproterenol in a chloride-free solution (ΔCl- free-isoproterenol). PD test is applied for CF diagnosis and monitoring of new therapeutic modulations and corrections.
Channel electron multiplier compatibility with Viton and Apiezon-L vacuum grease
NASA Astrophysics Data System (ADS)
McComas, D. J.; Baldonado, J. R.; Bame, S. J.; Barraclough, B. L.
1987-12-01
Clean Viton and Viton coated with Apiezon-L vacuum grease were tested for their noncontaminating compatibility with channel electron multipliers (CEMs). The test setup and procedure were the same as those used previously in conjunction with CEM compatibility tests of certain epoxies, solder, and fluorocarbon polymer materials useful for construction of spaceflight sensors. While some CEM gain degradation was noted during exposure to Viton and Apiezon-L, the present tests indicate that, at least over instrument lifetimes of about 2 x 10 to the 12th counts, these materials should be suitable for (1) preflight space sensor testing systems, (2) hermetic seals for CEM-based space sensors, and (3) terrestrial CEM-based instrumentation.
Compatibility testing of spacecraft materials and space-storable liquid propellants
NASA Technical Reports Server (NTRS)
Constantino, L. L.; Denson, J. R.; Krishnan, C. S.; Toy, A.
1974-01-01
Compatibility measurements were made for aluminum 2219-T87 alloy and titanium 6Al-4V alloy in the presence of liquid fluorine and flox. Results of post test characterization after exposure durations of 61 and 70 weeks are presented. Results of the total test program are analyzed.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Toxicology Testing. Labeling (dose limits). Electromagnetic incompatibility........ Electromagnetic... analysis and nonclinical testing must validate electromagnetic compatibility performance, wireless... electromagnetic compatibility performance, wireless performance, and electrical safety; and (4) Labeling must...
La Pean, Alison; Farrell, Michael H.; Eskra, Kerry L.; Farrell, Philip M.
2012-01-01
Objectives To assess whether reporting “possible cystic fibrosis (CF)” newborn screening (NBS) results via fax plus simultaneous telephone contact with primary care providers (PCPs), versus fax alone, influenced three outcomes: getting a sweat chloride test, age at sweat chloride test, and sweat-testing before 8 weeks old. Study Design Retrospective cohort comparison of infants born in Wisconsin whose PCPs received telephone intervention (n=301), versus recent historical controls whose PCP did not (n=355). Intervention data were collected during a longitudinal research and quality improvement effort; de-identified comparison data were constructed from auxiliary NBS tracking information. Parametric and nonparametric statistical analyses tested for group differences. Results Most infants (92%) with “possible CF” NBS results whose PCPs lacked telephone intervention ultimately underwent sweat-testing, underlining efficacy for fax-only reporting. Telephone intervention was significantly associated with improvements in infants undergoing sweat-testing at both ≤6 and <8 weeks and a slight, but non-significant, 3.5-day reduction in infants’ age at sweat-testing. The effect of telephone intervention was greater for PCPs whose patients underwent sweat-testing at community-affiliated medical centers versus academic medical centers (p=0.008). Conclusion Reporting “possible CF” NBS results via fax plus simultaneous telephone follow-up with PCPs increases the number of infants who have sweat chloride tests before 8 weeks of age, when affected infants are more likely to receive full benefits of early diagnosis and treatment. PMID:23102590
Toxicity of fluoride to aquatic species and evaluation of toxicity modifying factors.
Pearcy, Krysta; Elphick, James; Burnett-Seidel, Charlene
2015-07-01
The present study was performed to investigate the toxicity of fluoride to a variety of freshwater aquatic organisms and to establish whether water quality variables contribute substantively to modifying its toxicity. Water hardness, chloride, and alkalinity were tested as possible toxicity modifying factors for fluoride using acute toxicity tests with Hyalella azteca and Oncorhynchus mykiss. Chloride appeared to be the major toxicity modifying factor for fluoride in these acute toxicity tests. The chronic toxicity of fluoride was evaluated with a variety of species, including 3 fish (Pimephales promelas, O. mykiss, and Salvelinus namaycush), 3 invertebrates (Ceriodaphnia dubia, H. azteca, and Chironomus dilutus), 1 plant (Lemna minor), and 1 alga (Pseudokirchneriella subcapitata). Hyalella azteca was the most sensitive species overall, and O. mykiss was the most sensitive species of fish. The role of chloride as a toxicity modifying factor was inconsistent between species in the chronic toxicity tests. © 2015 SETAC.
NASA Technical Reports Server (NTRS)
Cardenas, Henry E.; Alexander, Joshua B.; Kupwade-Patil,Kunal; Calle, Luz Marina
2009-01-01
This work field tested the use of electrokinetics for delivery of concrete sealing nanoparticles concurrent with the extraction of chlorides. Several cylinders of concrete were batched and placed in immersion at the Kennedy Space Center Beach Corrosion Test Site. The specimens were batched with steel reinforcement and a 4.5 wt.% (weight percent) content of sodium chloride. Upon arrival at Kennedy Space Center, the specimens were placed in the saltwater immersion pool at the Beach Corrosion Test Site. Following 30 days of saltwater exposure, the specimens were subjected to rapid chloride extraction concurrent with electrokinetic nanoparticle treatment. The treatments were operated at up to eight times the typical current density in order to complete the treatment in 7 days. The findings indicated that the short-term corrosion resistance of the concrete specimens was significantly enhanced as was the strength of the concrete.
Sampling and testing for chloride ion in concrete
DOT National Transportation Integrated Search
1977-08-01
One of the most severe problems facing the highway community is chloride ion-induced reinforcing steel corrosion and the subsequent deterioration of concrete bridge decks and marine structures. This report presents recommended methods for sampling an...
Tested Demonstrations. A Chemiluminescence Demonstration - Oxalyl Chloride Oxidation.
ERIC Educational Resources Information Center
Gilber, George L., Ed.
1979-01-01
This inexpensive, effective chemiluminescence demonstration requires minimal preparation. It is based on the oxidation of oxalyl chloride by hydrogen peroxide in the presence of an appropriate fluorescent sensitizer. The reaction mechanism is not completely understood. (BB)
Anderson, Collin; Boehme, Sabrina; Ouellette, Jacquelyn; Stidham, Chanelle; MacKay, Mark
2014-01-01
Purpose: The physical and chemical compatibility of intravenous acetaminophen with commonly administered injectable medications was evaluated. Methods: Simulated Y-site evaluation was accomplished by mixing 2 mL of acetaminophen (10 mg/mL) with 2 mL of an alternative intravenous medication and subsequently storing the mixture in a polypropylene syringe for 4 hours. The aliquot solutions were visually inspected and evaluated for crystal content at 4 hours by infusing 4 mL of the medication mixture through a 0.45-μm nitrocellulose filter disc. Medication mixtures that were selected for chemical stability testing were analyzed by high-performance liquid chromatography at 0, 1, and 4 hours using a Zorbax Eclipse Plus C18, 4.6 x 100 mm, 3.5-μm column for separation of analytes with subsequent diode-array detection. Medications were considered chemically compatible if the concentrations of all components were >90% of the original concentrations during the 4 hour simulated Y-site compatibility test. Results: U.S. Pharmacopeial Convention (USP) standards for physical particle counts were met for acetaminophen injection (10 mg/mL) when combined with cefoxitin, ceftriaxone, clindamycin, dexamethasone, diphenhydramine, dolasetron, fentanyl, granisetron, hydrocortisone, hydromorphone, ketorolac, meperidine, methylprednisolone, midazolam, morphine, nalbuphine, ondansetron, piperacillin/tazobactam, ranitidine, and vancomycin. Injectable acetaminophen is incompatible with acyclovir and diazepam and therefore should not be administered concomitantly with either of these products. Further testing confirmed the chemical compatibility of acetaminophen with ceftriaxone, diphenhydramine, granisetron, ketorolac, nalbuphine, ondansetron, piperacillin/tazobactam, and vancomycin. Conclusion: All medications tested with acetaminophen were physically compatible except for acyclovir and diazepam. All 8 medications tested for chemical compatibility with acetaminophen were stable over the 4 hour simulated Y-site administration study. PMID:24421562
2005-01-01
Cold Foam 1% ethylene glycol 1% benzalkonium chloride 1% polyvinylpolypyrrolidone 1% Brij 58 1% Benzyldimethyl tetradecyl ammonium chloride dihydrate...described in this report was authorized by the Defense Threat Reduction Agency. This work was started in December 2003 and completed in March 2004. The...LITERA TURE CITED ..................................................................................... 15 5 FIGURES 1. Rates of Chloride Release in
Detecting the Water-soluble Chloride Distribution of Cement Paste in a High-precision Way.
Chang, Honglei; Mu, Song
2017-11-21
To improve the accuracy of the chloride distribution along the depth of cement paste under cyclic wet-dry conditions, a new method is proposed to obtain a high-precision chloride profile. Firstly, paste specimens are molded, cured, and exposed to cyclic wet-dry conditions. Then, powder samples at different specimen depths are grinded when the exposure age is reached. Finally, the water-soluble chloride content is detected using a silver nitrate titration method, and chloride profiles are plotted. The key to improving the accuracy of the chloride distribution along the depth is to exclude the error in the powderization, which is the most critical step for testing the distribution of chloride. Based on the above concept, the grinding method in this protocol can be used to grind powder samples automatically layer by layer from the surface inward, and it should be noted that a very thin grinding thickness (less than 0.5 mm) with a minimum error less than 0.04 mm can be obtained. The chloride profile obtained by this method better reflects the chloride distribution in specimens, which helps researchers to capture the distribution features that are often overlooked. Furthermore, this method can be applied to studies in the field of cement-based materials, which require high chloride distribution accuracy.
NASA Astrophysics Data System (ADS)
Park, Sun-Ah; Kim, Seon-Hong; Yoo, Yun-Ha; Kim, Jung-Gu
2015-05-01
The influence of the addition of HCl on the corrosion behavior of low-alloy steel containing copper and antimony was investigated using electrochemical (potentiodynamic and potentiostatic polarization tests, and electrochemical impedance spectroscopy) and weight loss tests in a 1.6M H2SO4 solution with different concentrations of hydrochloric acid (0.00, 0.08, 0.15 and 0.20 M HCl) at 60 °C. The result showed that the corrosion rate decreased with increasing HCl by the formation of protective layers. SEM, EDS and XPS examinations of the corroded surfaces after the immersion test indicated that the corrosion production layer formed in the solution containing HCl was highly comprised of metallic Cu, Cu chloride and metallic (Fe, Cu, Sb) compounds. The corrosion resistance was improved by the Cu-enriched layer, in which chloride ions are an accelerator for cupric ion reduction during copper deposition. Furthermore, cuprous and antimonious chloride species are complex salts for cuprous ions adsorbed on the surface during copper deposition.
NASA Technical Reports Server (NTRS)
Hirsch, David; Johnson, Harry
1994-01-01
The NASA Lewis Research Center requested NASA Johnson Space Center White Sands Test Facility to conduct flammability, odor, offgassing, thermal vacuum stability, and compatibility tests with aerospace fluids of several wire insulations.
Effect of ultrasound on electrochemical chloride extraction from mortar
NASA Astrophysics Data System (ADS)
Chen, Yiqun; Yao, Wu; Zuo, Junqing
2018-03-01
In this paper, the effect of auxiliary ultrasound on electrochemical chloride extraction (ECE) was studied. The chloride removal efficiency was investigated by examining the chloride content with ultrasound-assisted ECE and changing the introducing time of ultrasound. The experimental results showed that removal of chloride ions was noted to be more effective in ECE treatment assisted with ultrasound treatment (UT). In addition, the lower w/c ratio led to more distinct effect of ultrasonic cavitation on chloride removal. Electrochemical behaviors measured with different treatment revealed that UT treatment was effective on moderating the corrosion condition. Microstructural analyses revealed a significant alteration in composition and morphology of cementitious phases with UT treatment. Pull-out tests indicated that ultrasound had a certain negative impact on the bond strength. Although the effect of introducing ultrasound in the first 2 weeks or the last 2 weeks on the extraction efficiency was not obvious, intermittent ultrasound could not only ensure the chloride extraction efficiency, but also reduce the adverse effect of ultrasound on the bond strength.
42 CFR 84.253 - Chemical-cartridge respirators; requirements and tests.
Code of Federal Regulations, 2010 CFR
2010-10-01
... cartridges or pairs of cartridges continuously at a concentration of 10 ppm vinyl chloride monomer at a total... respirator by a breathing machine at a concentration of 10 ppm vinyl chloride monomer at the rate of 24...
Testing the Chloride Penetration Resistance of Concrete : A Literature Review.
DOT National Transportation Integrated Search
2001-01-01
One of the major forms of environmental attack on reinforced concrete bridges is chloride ingress, which leads to corrosion of the reinforcing steel and a subsequent reduction in the strength, serviceability, and aesthetics of the structure.Reinforce...
USDA-ARS?s Scientific Manuscript database
In a series of experiments cyanuric chloride and hexachlorocyclotriphosphazene derivatives were synthesized and characterized using spectroscopic, thermogravimetric, limiting oxygen index, and vertical flame analyses. Standardized test results have determined these compounds are promising flame reta...
NASA Technical Reports Server (NTRS)
Harrison, Cecil A.
1986-01-01
The efforts to automate the electromagentic compatibility (EMC) test facilites at Marshall Flight Center were examined. A battery of nine standard tests is to be integrated by means of a desktop computer-controller in order to provide near real-time data assessment, store the data acquired during testing on flexible disk, and provide computer production of the certification report.
Oxygen Compatibility Testing of Composite Materials
NASA Technical Reports Server (NTRS)
Graf, Neil A.; Hudgins, Richard J.; McBain, Michael
2000-01-01
The development of polymer composite liquid oxygen LO2 tanks is a critical step in creating the next generation of launch vehicles. Future launch vehicles need to minimize the gross liftoff weight (GLOW), which is possible due to the 25%-40% reduction in weight that composite materials could provide over current aluminum technology. Although a composite LO2 tank makes these weight savings feasible, composite materials have not historically been viewed as "LO2 compatible." To be considered LO2 compatible, materials must be selected that will resist any type of detrimental, combustible reaction when exposed to usage environments. This is traditionally evaluated using a standard set of tests. However, materials that do not pass the standard tests can be shown to be safe for a particular application. This paper documents the approach and results of a joint NASA/Lockheed Martin program to select and verify LO2 compatible composite materials for liquid oxygen fuel tanks. The test approach developed included tests such as mechanical impact, particle impact, puncture, electrostatic discharge, friction, and pyrotechnic shock. These tests showed that composite liquid oxygen tanks are indeed feasible for future launch vehicles.
Sweat Chlorides in Salt-Deprived Cystic Fibrosis Heterozygotes
Myers, Michael F.
1965-01-01
Sweat chlorides of 10 sets of parents of children with cystic fibrosis and 11 controls were studied in an attempt to develop a test for the diagnosis of cystic fibrosis heterozygotes by subjecting both the parents and controls to a low sodium diet and comparing sweat chloride values as the diet progressed. It was hoped that the sweat chloride levels of the parents, the heterozygotes, would remain stationary throughout the diet, since their children, the homozygotes, reveal this finding under similar conditions of salt deprivation. The sweat chloride levels of the controls, because of effects of aldosterone, were expected to decrease steadily from the commencement of the diet to its termination. A decrease in sweat chloride values of similar magnitude was found in both parents and controls as the diet continued. It is concluded that the study of sweat electrolyte levels in salt-deprived subjects is of no value in the diagnosis of cystic fibrosis heterozygotes. PMID:14289142
The effect of plasma on shear bond strength between resin cement and colored zirconia
2017-01-01
PURPOSE To investigate the effect of non-thermal atmospheric pressure plasma (NTAPP) treatment on shear bond strength (SBS) between resin cement and colored zirconia made with metal chlorides. MATERIALS AND METHODS 60 zirconia specimens were divided into 3 groups using coloring liquid. Each group was divided again into 2 sub-groups using plasma treatment; the experimental group was treated with plasma, and the control group was untreated. The sub-groups were: N (non-colored), C (0.1 wt% aqueous chromium chloride solution), M (0.1 wt% aqueous molybdenum chloride solution), NP (non-colored with plasma), CP (0.1 wt% aqueous chromium chloride solution with plasma), and MP (0.1 wt% aqueous molybdenum chloride solution with plasma). Composite resin cylinders were bonded to zirconia specimens with MDP-based resin cement, and SBS was measured using a universal testing machine. All data was analyzed statistically using a 2-way ANOVA test and a Tukey test. RESULTS SBS significantly increased when specimens were treated with NTAPP regardless of coloring (P<.001). Colored zirconia containing molybdenum showed the highest value of SBS, regardless of NTAPP. The molybdenum group showed the highest SBS, whereas the chromium group showed the lowest. CONCLUSION NTAPP may increase the SBS of colored zirconia and resin cement. The NTAPP effect on SBS is not influenced by the presence of zirconia coloring. PMID:28435621
Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.
Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C
2018-03-23
Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Rapid methods for the isolation of actinides Sr, Tc and Po from raw urine.
McAlister, Daniel R; Horwitz, E Philip; Harvey, James T
2011-08-01
Rapid methods for the isolation and analysis of individual actinides (Th, U, Pu, Am/Cm) and Sr, Tc and Po from small volumes of raw urine have been developed. The methods involve acidification of the sample and the addition of aluminum nitrate or aluminum chloride salting-out agent prior to isolation of the desired analyte using a tandem combination of prefilter material and extraction chromatographic resin. The method has been applied to the separation of individual analytes from spiked urine samples. Analytes were recovered in high yield and radionuclide purity with separation times as low as 30 min. The chemistry employed is compatible with automation on the ARSIIe instrument.
Polymer scaffold degradation control via chemical control
Hedberg-Dirk, Elizabeth L.; Dirk, Shawn; Cicotte, Kirsten
2016-01-05
A variety of polymers and copolymers suitable for use as biologically compatible constructs and, as a non-limiting specific example, in the formation of degradable tissue scaffolds as well methods for synthesizing these polymers and copolymers are described. The polymers and copolymers have degradation rates that are substantially faster than those of previously described polymers suitable for the same uses. Copolymers having a synthesis route which enables one to fine tune the degradation rate by selecting the specific stoichiometry of the monomers in the resulting copolymer are also described. The disclosure also provides a novel synthesis route for maleoyl chloride which yields monomers suitable for use in the copolymer synthesis methods described herein.
NASA Technical Reports Server (NTRS)
Burrows, W. H.; Burrows, W. H.
1971-01-01
A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.
Application of biological filters in water treatment systems
NASA Technical Reports Server (NTRS)
Hurley, T. L.; Bambenek, R. A.
1973-01-01
Silver chloride placed on or close to barrier kills bacteria as they arrive. Dead bacteria accumulate linearly, whereas previously, live bacteria accumulated exponentially. During continuous 30-day tests, no bacteriological contamination was found downstream of filters with silver chloride added.
Effect of chloride-based deicers on reinforced concrete structures.
DOT National Transportation Integrated Search
2012-07-01
We conducted an extensive literature review and performed laboratory tests to assess the effect of chloride-based deicers on the rebars and dowel bars in concrete and to determine whether or not deicer corrosion inhibitors help preserve the transport...
Normal sweat chloride test does not rule out cystic fibrosis.
Başaran, Abdurrahman Erdem; Karataş-Torun, Nimet; Maslak, İbrahim Cemal; Bingöl, Ayşen; Alper, Özgül M
2017-01-01
Başaran AE, Karataş-Torun N, Maslak İC, Bingöl A, Alper ÖM. Normal sweat chloride test does not rule out cystic fibrosis. Turk J Pediatr 2017; 59: 68-70. A 5-month-old patient presented with complaints of fever and cough. He was hospitalized with the diagnosis of bronchopneumonia and pseudo-Bartter's syndrome. Patient was further investigated for diagnosis of cystic fibrosis. The chloride (Cl) level in sweat was determined within the normal range (25.1 mmol/L, 20.3 mmol/L). CFTR (Cystic Fibrosis Transmembrane Regulator gene; NM_000492.2) genotyping results were positive for p.E92K; p.F1052V mutations. The patient was diagnosed with cystic fibrosis. In our patient, with features of CF and normal sweat test, mutation analysis was helpful for the diagnosis of cystic fibrosis.
NASA Technical Reports Server (NTRS)
Perry, J. C.
1975-01-01
A series of electromagnetic compatibility (EMC) tests were conducted in May, 1975 in the Soviet Union. The purpose of the EMC tests was to determine the effects of the operating environment of the Soviet aircraft, Soyuz, upon the electrical performance of the USA's cable communications equipment located in Soyuz. The test procedures necessary to check out the cable communications test configuration in preparation for the EMC tests are presented.
78 FR 35173 - Physical Medicine Devices; Reclassification of Stair-Climbing Wheelchairs
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-12
.... Electromagnetic interference: The device may interfere with the operation of other electrical devices or be... electromagnetic compatibility testing as well as characterization of speed/acceleration, battery longevity, and... electrical safety and electromagnetic compatibility of the device. Performance testing must demonstrate...
Swaile, D F; Elstun, L T; Benzing, K W
2012-03-01
Individuals with axillary hyperhidrosis have much higher than average sweat rates and are often prescribed anhydrous aluminum chloride (AlCl(3)) solutions. Topical application of these solutions can be irritating to the skin, resulting in poor compliance and lower than desired efficacy. Demonstrate the efficacy of an over the counter "clinical strength" soft-solid antiperspirant using a night time application regimen and compare to a prescription aluminum chloride (6.5%) antiperspirant using male panelists. Gravimetric hot room efficacy testing (100 F and 35% Humidity) was performed comparing an over the counter soft-solid antiperspirant to placebo in a single test. Two separate gravimetric tests were placed comparing a prescription aluminum chloride (6.5%) antiperspirant to the same soft solid product using an intent to treat model. Skin irritation was assessed daily by a trained grader. Placebo testing resulted in 85% of panelists having a reduction in sweating rate greater than 50%. Comparison testing showed the over the counter soft solid reduced sweat rate by an average of 34% better than the prescription product while resulting significantly less skin irritation. Over the counter "clinical strength" soft-solid antiperspirants can be considered as an alternative treatment to aluminum chloride antiperspirants for the treatment of heavy sweating. © 2012 The Author. BJD © 2012 British Association of Dermatologists.
Uptake of Tl-201 in the testes: Implications for radiation dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stabin, M.G.; Thomas, S.R.; Wilson, R.A.
The radiation dose to the testes from Tl-201 chloride has been an outstanding question for a number of years. Previous studies have presented kinetic data for the testes with percentage uptake ranging over nearly an order of magnitude from 0.15% to 1.2%. Gupta et al. studied the uptake of Tl-201 in testes and reported an uptake of 0.9-1.2%, with no clearance to 24 hours. Use of the value reported by Gupta et al. results in an estimated dose to the testes in the adult of 0.82 mGy/MBq, and causes the testes to be identified as the highest dose organ. Inmore » our crossover study we evaluated Tl-201 uptake in the testes of 28 patients who received Tl-201 chloride plus D-Ribose, an experimental clearance agent, and Tl-201 chloride plus a placebo 7 to 14 days later. Quantitative measurements were made under a scintillation camera imaging protocol (following exercise and administration of D-Ribose or the placebo) at approximately 1.5, 4.5, 8, 24, and 48 hr, and 7 to 14 days post injection, during which the isolated testes were shielded from the body background. Images were acquired for 5 minutes at early times and 10 to 15 minutes at the latest time. The data were fit to a two component exponential curve. Uptake and clearance parameters were not significantly different between the two regimens. Mean uptake was 0.31 {plus_minus} 0.11%; the mean residence time in the testes was 0.26 {plus_minus}0.08 hr. The testes dose using this new residence time is about 0.20 mGy/MBq. This estimate should form the basis for testicular radiation dosimetry of Tl-201 chloride.« less
APPLICATION OF VACUUM SALT DISTILLATION TECHNOLOGY FOR THE REMOVAL OF FLUORIDE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, R.; Pak, D.
2011-08-10
Vacuum distillation of chloride salts from plutonium oxide (PuO{sub 2}) and simulant PuO{sub 2} has been previously demonstrated at Department of Energy (DOE) sites using kilogram quantities of chloride salt. The apparatus for vacuum distillation contains a zone heated using a furnace and a zone actively cooled using either recirculated water or compressed air. During a vacuum distillation operation, a sample boat containing the feed material is placed into the apparatus while it is cool, and the system is sealed. The system is evacuated using a vacuum pump. Once a sufficient vacuum is attained, heating begins. Volatile salts distill frommore » the heated zone to the cooled zone where they condense, leaving behind the non-volatile materials in the feed boat. The application of vacuum salt distillation (VSD) is of interest to the HB-Line Facility and the MOX Fuel Fabrication Facility (MFFF) at the Savannah River Site (SRS). Both facilities are involved in efforts to disposition excess fissile materials. Many of these materials contain chloride and fluoride salt concentrations which make them unsuitable for dissolution without prior removal of the chloride and fluoride salts. Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and HB-Line designed, developed, tested, and successfully deployed a system for the distillation of chloride salts. Subsequent efforts are attempting to adapt the technology for the removal of fluoride. Fluoride salts of interest are less-volatile than the corresponding chloride salts. Consequently, an alternate approach is required for the removal of fluoride without significantly increasing the operating temperature. HB-Line Engineering requested SRNL to evaluate and demonstrate the feasibility of an alternate approach using both non-radioactive simulants and plutonium-bearing materials. Whereas the earlier developments targeted the removal of sodium chloride (NaCl) and potassium chloride (KCl), the current activities are concerned with the removal of the halide ions associated with plutonium trifluoride (PuF{sub 3}), plutonium tetrafluoride (PuF{sub 4}), calcium fluoride (CaF{sub 2}), and calcium chloride (CaCl{sub 2}). This report discusses non-radioactive testing of small-scale and pilot-scale systems and radioactive testing of a small-scale system. Experiments focused on demonstrating the chemistry for halide removal and addressing the primary engineering questions associated with a change in the process chemistry.« less
Compounded Apixaban Suspensions for Enteral Feeding Tubes.
Caraballo, Maria L; Donmez, Seda; Nathan, Kobi; Zhao, Fang
2017-07-01
Objective: There is limited information on compounded apixaban formulations for administration via enteral feeding tubes. This study was designed to identify a suitable apixaban suspension formulation that is easy to prepare in a pharmacy setting, is compatible with commonly used feeding tubes, and has a beyond-use date of 7 days. Methods: Apixaban suspensions were prepared from commercially available 5-mg Eliquis tablets. Several vehicles and compounding methods were screened for ease of preparation, dosage accuracy, and tube compatibility. Two tubing types, polyurethane and polyvinyl chloride, with varying lengths and diameters, were included in the study. They were mounted on a peg board during evaluation to mimic the patient body position. A 7-day stability study of the selected formulation was also conducted. Results: Vehicles containing 40% to 60% Ora-Plus in water all exhibited satisfactory flowability through the tubes. The mortar/pestle compounding method was found to produce more accurate and consistent apixaban suspensions than the pill crusher or crushing syringe method. The selected formulation, 0.25 mg/mL apixaban in 50:50 Ora-Plus:water, was compatible with both tubing types, retaining >98% drug in posttube samples. The stability study also confirmed that this formulation was stable physically and chemically over 7 days of storage at room temperature. Conclusions: A suitable apixaban suspension formulation was identified for administration via enteral feeding tubes. The formulation consisted of 0.25 mg/mL apixaban in 50:50 Ora-Plus:water. The stability study results supported a beyond-use date of 7 days at room temperature.
Stress Corrosion Cracking of an Austenitic Stainless Steel in Nitrite-Containing Chloride Solutions
Singh Raman, R. K.; Siew, Wai Hoong
2014-01-01
This article describes the susceptibility of 316L stainless steel to stress corrosion cracking (SCC) in a nitrite-containing chloride solution. Slow strain rate testing (SSRT) in 30 wt. % MgCl2 solution established SCC susceptibility, as evidenced by post-SSRT fractography. Addition of nitrite to the chloride solution, which is reported to have inhibitive influence on corrosion of stainless steels, was found to increase SCC susceptibility. The susceptibility was also found to increase with nitrite concentration. This behaviour is explained on the basis of the passivation and pitting characteristics of 316L steel in chloride solution. PMID:28788276
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-10
... basic safety and essential performance--Collateral standard: Electromagnetic compatibility--Requirements... standard: Electromagnetic compatibility--Requirements and tests 5-34 5-53 IEC 60601-1-2 Third edition 2007... for basic safety and essential performance--Collateral standard: Electromagnetic compatibility...
Alahakoon, Amali U.; Jayasena, Dinesh D.; Jung, Samooel; Kim, Sun Hyo
2014-01-01
Chicken breast meat was injected with calcium chloride alone and in combination with lactic acid (0.01% and 0.002%, respectively). The inhibitory effects of the treatments on microbial growth were determined in the injected chicken breast meat stored at 4°C under aerobic packaging condition for 0, 3, and 7 d. Calcium chloride combined with 0.002% and 0.01% lactic acid reduced microbial counts by 0.14 and 1.08 Log CFU/g, respectively, however, calcium chloride alone was unable to inhibit microbial growth. Calcium chloride combined with 0.01% lactic acid was the most effective antimicrobial treatment and resulted in the highest initial redness value. Calcium chloride alone and combined with lactic acid suppressed changes in pH and the Hunter color values during storage. However, injection of calcium chloride and lactic acid had adverse effects on lipid oxidation and sensory characteristics. The higher TBARS values were observed in samples treated with calcium chloride and lactic acid when compared to control over the storage period. Addition of calcium chloride and lactic acid resulted in lower sensory scores for parameters tested, except odor and color, compared to control samples. Therefore, the formulation should be improved in order to overcome such defects prior to industrial application. PMID:26760942
Influence of Chloride-Ion Adsorption Agent on Chloride Ions in Concrete and Mortar.
Peng, Gai-Fei; Feng, Nai-Qian; Song, Qi-Ming
2014-04-30
The influence of a chloride-ion adsorption agent (Cl agent in short), composed of zeolite, calcium aluminate hydrate and calcium nitrite, on the ingress of chloride ions into concrete and mortar has been experimentally studied. The permeability of concrete was measured, and the chloride ion content in mortar was tested. The experimental results reveal that the Cl agent could adsorb chloride ions effectively, which had penetrated into concrete and mortar. When the Cl agent was used at a dosage of 6% by mass of cementitious materials in mortar, the resistance to the penetration of chloride ions could be improved greatly, which was more pronounced when a combination of the Cl agent and fly ash or slag was employed. Such an effect is not the result of the low permeability of the mortar, but might be a result of the interaction between the Cl agent and the chloride ions penetrated into the mortar. There are two possible mechanisms for the interaction between the Cl agent and chloride ion ingress. One is the reaction between calcium aluminate hydrate in the Cl agent and chloride ions to form Friedel's salt, and the other one is that calcium aluminate hydrate reacts with calcium nitrite to form AFm during the early-age hydration of mortar and later the NO₂ - in AFm is replaced by chloride ions, which then penetrate into the mortar, also forming Friedel's salt. More research is needed to confirm the mechanisms.
Influence of Chloride-Ion Adsorption Agent on Chloride Ions in Concrete and Mortar
Peng, Gai-Fei; Feng, Nai-Qian; Song, Qi-Ming
2014-01-01
The influence of a chloride-ion adsorption agent (Cl agent in short), composed of zeolite, calcium aluminate hydrate and calcium nitrite, on the ingress of chloride ions into concrete and mortar has been experimentally studied. The permeability of concrete was measured, and the chloride ion content in mortar was tested. The experimental results reveal that the Cl agent could adsorb chloride ions effectively, which had penetrated into concrete and mortar. When the Cl agent was used at a dosage of 6% by mass of cementitious materials in mortar, the resistance to the penetration of chloride ions could be improved greatly, which was more pronounced when a combination of the Cl agent and fly ash or slag was employed. Such an effect is not the result of the low permeability of the mortar, but might be a result of the interaction between the Cl agent and the chloride ions penetrated into the mortar. There are two possible mechanisms for the interaction between the Cl agent and chloride ion ingress. One is the reaction between calcium aluminate hydrate in the Cl agent and chloride ions to form Friedel’s salt, and the other one is that calcium aluminate hydrate reacts with calcium nitrite to form AFm during the early-age hydration of mortar and later the NO2− in AFm is replaced by chloride ions, which then penetrate into the mortar, also forming Friedel’s salt. More research is needed to confirm the mechanisms. PMID:28788625
Evaluation of Deicer Impacts on Pervious Concrete Specimens (Phase II)
DOT National Transportation Integrated Search
2018-05-01
This research examined the chemical degradation of pervious concrete due to calcium chloride or magnesium chloride deicers. The project consisted of Phase I, Phase IIa, and Phase IIb. Phase I was previous work where a testing protocol was developed t...
Surface resistivity as an alternative for rapid chloride permeability test of hardened concrete.
DOT National Transportation Integrated Search
2015-03-01
Kansas experiences harsh winters that require frequent use of de-icing salts, making it critical to the long-term : durability of concrete structures that the permeability is kept under control. Under current KDOT specification, the : Rapid Chloride ...
An in vitro investigation into the physical properties of irreversible hydrocolloid alternatives.
Patel, Rishi D; Kattadiyil, Mathew T; Goodacre, Charles J; Winer, Myron S
2010-11-01
A number of manufacturers have introduced new products that are marketed as alternatives to irreversible hydrocolloid impression materials. However, there is a paucity of laboratory and clinical research on these products compared to traditional irreversible hydrocolloid. The purpose of this study was to evaluate the detail reproduction, gypsum compatibility, and linear dimensional change of 3 recently introduced impression materials designed as alternatives to irreversible hydrocolloid. The tested materials were Position Penta Quick, Silgimix, and AlgiNot. An irreversible hydrocolloid impression material, Jeltrate Plus Antimicrobial, served as the control. The parameters of detail reproduction, gypsum compatibility, and linear dimensional change were tested in accordance with ANSI/ADA Specifications No. 18 and 19. The gypsum compatibility was tested using a type III stone (Microstone Golden) and a type IV stone (Die-Keen Green). The data were analyzed using the Kruskal-Wallis rank test and the Mann-Whitney U test (α=.05). The test materials demonstrated significantly (P<.001) better detail reproduction than the control material. Silgimix exhibited the best compatibility with Microstone, whereas AlgiNot and Position Penta Quick exhibited the best gypsum compatibility with Die-Keen. An incompatibility was observed over time between the Jeltrate control material and the Microstone gypsum material. For linear dimensional change, the mean dimension of the control material most closely approximated the distance between the lines on the test die, but it exhibited the greatest variability in measurements. All of the test materials exhibited linear dimensional change within the ADA's accepted limit of 1.0%. The 3 new impression materials exhibited better detail reproduction and less variability in linear dimensional change than the irreversible hydrocolloid control. Gypsum compatibility varied with the brand of gypsum used, with an incompatibility identified between the control material (Jeltrate Plus Antimicrobial) and Microstone related to surface changes observed over time. Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Nguyen, Tuan Anh; Nguyen, The Huyen; Pham, Thi Lua; Dinh, Thi Mai Thanh Dinh; Thai, Hoang; Shi, Xianming
2017-01-01
The effect of incorporating nanoparticles on the corrosion resistance of epoxy-coated steel in salt contaminated mortars was investigated using potentiodynamic polarization and electrochemical impedance spectroscopy. Researchers conducted electrochemical monitoring of the coated steel embedded in mortar over 100 days of immersion in 0.1 M NaOH solutions. The chloride permeability and microstructure of Portland cement mortar with admixed nano-materials (at 1% by weight of cement) were examined using an electromigration test and field emission scanning electron microscopy (FESEM). Electrochemical monitoring showed that nano Fe₂O₃ improved the corrosion resistance of the coated rebar. The incorporation of a small amount of nano Fe₂O₃ (1% by total weight of resin and hardener) into the epoxy coating reduced the corrosion current of the epoxy-coated steel in chloride-contaminated mortar (0.3% chloride by weight of cement). After 100 days of immersion, the nanoparticles reduced the corrosion current of epoxy-coated steel by a factor of 6. The FESEM test revealed that admixing of nano-materials not only led to denser cement mortar but also changed the morphology of cement hydration products. The test results of compressive strength showed that nanoparticles increased the strength of cement mortar. The electromigration test showed that the incorporation of nanoparticles improved the chloride penetration resistance of the mortar, as indicated by the reduced apparent diffusion coefficients of the chloride anion. When nano-SiO₂ and nano-Fe₂O₃ were admixed into fresh cement mortar at 1% by weight of cement, the value of D(Cl−) was decreased by 83%, from 7.35×10(−11) m²/s (control specimen) to 1.21×10(−11) m²/s and 1.36×10(−11) m²/s, respectively.
NASA Technical Reports Server (NTRS)
Cardenas, Henry; Alexander, Joshua; Kupwade-Patil, Kunal; Calle, Luz marina
2010-01-01
Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to field conditions at one of the most severely corrosive environments in North America.
Jiang, Yu; Yu, Bo; Wang, Xue; Sui, Yujie; Zhang, Yaofang; Yang, Shuang; Yang, Hong; Ma, Tonghui
2014-12-01
Cystic fibrosis transmembrane conductance regulator (CFTR) is a cAMP-activated chloride channel expressed in the apical membrane of serous epithelial cells. Both deficiency and overactivation of CFTR may cause fluid and salt secretion related diseases. In the present study, we identified tangeretin from Pericarpium Citri Reticulatae Viride as a CFTR activator using high-throughput screening based on FRT cell-based fluorescence assay. The activation effect of tangeretin on CFTR chloride channel and the possible underlying mechanisms were investigated. Fluorescence quenching tests showed that tangeretin dose- and time-dependently activated CFTR chloride channel, the activity had rapid and reversible characteristics and the activation effect could be completely reversed by the CFTR specific blocker CFTRinh-172. Primary mechanism studies indicated that the activation effect of tangeretin on CFTR chloride channel was FSK dependent as well as had additional effect with FSK and IBMX suggesting that tangeretin activates CFTR by direct interacting with the protein. Ex-vivo tests revealed that tangeretin could accelerate the speed of the submucosal gland fluid secretion. Short-circuit current measurement demonstrated that tangeretin activated rat colonic mucosa chloride current. Thus, CFTR Cl(-) channel is a molecular target of natural compound tangeretin. Tangeretin may have potential use for the treatment of CFTR-related diseases like cystic fibrosis, bronchiectasis and habitual constipation. Copyright © 2014 Elsevier B.V. All rights reserved.
Gunderson, Mark P; Nguyen, Brandon T; Cervantes Reyes, Juan C; Holden, Laura L; French, John M T; Smith, Brandon D; Lineberger, Connor
2018-05-30
Metals and pesticides are common pollutants and the modulation of biomarkers can indicate sub-lethal influences on the physiology of organisms inhabiting impacted aquatic systems. We examined the effects of mercury and the organophosphate pesticide dimethoate on EROD, MROD, glutathione S-transferase (GST), acetylcholine esterase (AChE), metallothionein (MT) and glutathione (GSH) in the signal crayfish (Pacifastacus leniusculus). Crayfish were injected with mercury chloride or dimethoate (0.3, 0.6, 0.9 μg kg -1 ) and dissected after 72 h. EROD activity in the hepatopancreas did not change in response to mercury chloride treatment but exhibited a dose dependent decrease at all concentrations of dimethoate tested. MROD (hepatopancreas) exhibited a significant decrease at the 0.9 μg kg -1 treatment for both chemicals. GST (hepatopancreas) demonstrated a significant dose dependent decrease at all concentrations of both mercury chloride and dimethoate. AChE (tail muscle) decreased at the 0.6 and 0.9 μg kg -1 concentrations of dimethoate and 0.9 μg kg -1 mercury chloride. In gill tissue, MT increased in response to 0.3 and 0.6 μg kg -1 of mercury chloride but no effect was observed at the 0.9 μg kg -1 concentration of mercury chloride or any concentrations of dimethoate tested. MT did not change in response to mercury or dimethoate in tail tissue. Furthermore, neither chemical modulated GSH concentrations. Our results indicate that, apart from GSH, these markers are sensitive to the pollutants tested and that animals exposed in the wild are potentially compromised in their ability to detoxify environmental contaminants and carry out normal cellular processes. Copyright © 2018 Elsevier Ltd. All rights reserved.
Genomic and post-genomic effects of anti-glaucoma drugs preservatives in trabecular meshwork.
Izzotti, Alberto; La Maestra, Sebastiano; Micale, Rosanna Tindara; Longobardi, Maria Grazia; Saccà, Sergio Claudio
2015-02-01
Oxidative stress plays an important role in glaucoma. Some preservatives of anti-glaucoma drugs, commonly used in glaucoma therapy, can prevent or induce oxidative stress in the trabecular meshwork. The aim of this study is to evaluate cellular and molecular damage induced in trabecular meshwork by preservatives contained in anti-glaucoma drugs. Cell viability (MTT test), DNA fragmentation (Comet test), oxidative DNA damage (8-oxo-dG), and gene expression (cDNA microarray) have been evaluated in trabecular meshwork specimens and in human trabecular meshwork cells treated with benzalkonium chloride, polyQuad, purite, and sofzia-like mixture. Moreover, antimicrobial effectiveness and safety of preservative contents in drugs was tested. In ex vivo experiments, benzalkonium chloride and polyQuad induced high level of DNA damage in trabecular meshwork specimens, while the effect of purite and sofzia were more attenuated. The level of DNA fragmentation induced by benzalkonium chloride was 2.4-fold higher in subjects older than 50 years than in younger subjects. Benzalkonium chloride, and polyQuad significantly increased oxidative DNA damage as compared to sham-treated specimens. Gene expression was altered by benzalkonium chloride, polyQuad, and purite but not by sofzia. In in vitro experiments, benzalkonium chloride and polyQuad dramatically decreased trabecular meshwork cell viability, increased DNA fragmentation, and altered gene expression. A lesser effect was also exerted by purite and sofzia. Genes targeted by these alterations included Fas and effector caspase-3. The efficacy of the preservatives in inhibiting bacterial growth increased the adverse effects in trabecular meshwork in terms of DNA damage and alteration of gene expression. Presented data indicates the delicate balance between efficacy and safety of drug preservatives as not yet optimized. Copyright © 2014 Elsevier B.V. All rights reserved.
Effects of the thermal sterilization procedure on polymeric products
NASA Technical Reports Server (NTRS)
Campbell, B. A.; Kalfayan, S. H.
1971-01-01
Properties of samples are tested, after thermal exposure, and values are compared with unexposed samples. Thermal stability or compatibility ratings of formulated or compounded organic polymers using trade names are made and degree of change in measured properties is assessed. Products are rated compatible, marginal, or not compatible.
Fabrication and Performance of All-Solid-State Chloride Sensors in Synthetic Concrete Pore Solutions
Gao, Xiaojian; Zhang, Jian; Yang, Yingzi; Deng, Hongwei
2010-01-01
One type of all-solid-state chloride sensor was fabricated using a MnO2 electrode and a Ag/AgCl electrode. The potentiometric response of the sensor to chloride in synthetic concrete pore solutions was systematically studied, and the polarization performance was also evaluated. The results show a good linear relationship between the potential reading of the sensor and the logarithm of chloride activity (concentration ranges from 0.05 to 5.0 M), and the potential value remains stable with increasing immersion time. The existence of K+, Ca2+, Na+ and SO42− ions have little influence on the potentiometric response of the sensor to chloride, but the pH has a significant influence on the potential value of the sensor at low chloride concentration. The potential reading of the sensor increases linearly with the solution temperature over the range from 5 to 45 °C. Meanwhile, an excellent polarization behavior is proven by galvanostatic and potentiodynamic tests. All of the results reveal that the developed sensor has a great potential for monitoring chloride ions in concrete environments. PMID:22163467
Gao, Xiaojian; Zhang, Jian; Yang, Yingzi; Deng, Hongwei
2010-01-01
One type of all-solid-state chloride sensor was fabricated using a MnO(2) electrode and a Ag/AgCl electrode. The potentiometric response of the sensor to chloride in synthetic concrete pore solutions was systematically studied, and the polarization performance was also evaluated. The results show a good linear relationship between the potential reading of the sensor and the logarithm of chloride activity (concentration ranges from 0.05 to 5.0 M), and the potential value remains stable with increasing immersion time. The existence of K(+), Ca(2+), Na(+) and SO(4) (2-) ions have little influence on the potentiometric response of the sensor to chloride, but the pH has a significant influence on the potential value of the sensor at low chloride concentration. The potential reading of the sensor increases linearly with the solution temperature over the range from 5 to 45 °C. Meanwhile, an excellent polarization behavior is proven by galvanostatic and potentiodynamic tests. All of the results reveal that the developed sensor has a great potential for monitoring chloride ions in concrete environments.
Streker, Meike; Reuther, Tilmann; Hagen, Linda; Kerscher, Martina
2012-02-01
Primary focal hyperhidrosis plantaris can cause impairment in social, physical, leisure and occupational activities. Topical treatment with aluminium chloride is the first-line treatment. The aim of this trial was to evaluate efficacy and safety of two different concentrations of aluminium chloride hexa-hydrate (12.5%, 30%) for 6 weeks. 20 volunteers with hyperhidrosis plantaris were included. Efficacy was evaluated using a clinical rating scale of the hyperhidrosis level and qualitative assessments including Minor's (iodine-starch) test and a standardized sniff test. Furthermore a patient questionnaire and measurements of skin surface pH were done to evaluate the subjective assessments and side effects. The hyperhidrosis level significantly decreased in both concentrations. There were no differences in tolerability regarding the skin surface pH and the patient questionnaires. In addition the hidrotic areas decreased after application of both products and the sniff test improved. Topical application of an antiperspirant containing aluminium chloride reduced sweat production in plantar hyperhidrosis significantly. As both 12.5% and 30% were efficacious and safe, we would recommend 12.5% for outpatient treatment. © The Author • Journal compilation © Blackwell Verlag GmbH, Berlin.
Fedorova, Tamara; Brandlová, Karolína; Lukešová, Daniela
2015-06-01
Pregnancy diagnoses in half-tamed animals are often very complicated. This study aimed to examine the alternative noninvasive and cheap methods of pregnancy diagnosis from urine in domestic Bactrian camels (Camelus bactrianus). Urine from 14 female camels kept in four European zoologic gardens was collected and tested by two chemical tests--Cuboni reaction and barium chloride test. The Cuboni reaction was significantly (P<0.01) affected by the pregnancy status of female camels. The total accuracy of the Cuboni reaction was 70.5% but it increased significantly (P<0.05) in the time leading up to parturition. The accuracy was 100% in the 3rd third of pregnancy. Urine of nonpregnant females did not react with a solution of barium chloride while, contrary to other studies, white precipitates formed mostly (80 to 100%) in urine of pregnant females. This study concluded that the Cuboni reaction is applicable for pregnancy diagnosis in camels.
DOT National Transportation Integrated Search
2015-03-01
Kansas experiences harsh winters that require frequent use of de-icing salts, making it : critical to the long-term durability of concrete structures that the permeability is kept : under control. Under current KDOT specification, the Rapid Chloride ...
Materials Compatibility Testing in RSRM ODC: Free Cleaner Selection
NASA Technical Reports Server (NTRS)
Keen, Jill M.; Sagers, Neil W.; McCool, Alex (Technical Monitor)
2001-01-01
Government regulations have mandated production phase-outs of a number of solvents, including 1,1,1-trichloroethane, an ozone-depleting chemical (ODC). This solvent was used extensively in the production of the Reusable Solid Rocket Motors (RSRMs) for the Space Shuttle. Many tests have been performed to identify replacement cleaners. One major area of concern in the selection of a new cleaner has been compatibility. Some specific areas considered included cleaner compatibility with non-metallic surfaces, painted surfaces, support materials such as gloves and wipers as well as corrosive properties of the cleaners on the alloys used on these motors. The intent of this paper is to summarize the test logic, methodology, and results acquired from testing the many cleaner and material combinations.
Electromagnetic Compatibility Design of the Computer Circuits
NASA Astrophysics Data System (ADS)
Zitai, Hong
2018-02-01
Computers and the Internet have gradually penetrated into every aspect of people’s daily work. But with the improvement of electronic equipment as well as electrical system, the electromagnetic environment becomes much more complex. Electromagnetic interference has become an important factor to hinder the normal operation of electronic equipment. In order to analyse the computer circuit compatible with the electromagnetic compatibility, this paper starts from the computer electromagnetic and the conception of electromagnetic compatibility. And then, through the analysis of the main circuit and system of computer electromagnetic compatibility problems, we can design the computer circuits in term of electromagnetic compatibility. Finally, the basic contents and methods of EMC test are expounded in order to ensure the electromagnetic compatibility of equipment.
Effect of chloride contamination in MON-1 propellant on crack growth properties of metals
NASA Technical Reports Server (NTRS)
Moran, C. M.; Toth, L. R.
1981-01-01
The effect of a high level of chloride content (800 ppm) in MON-1 propellant on the crack growth properties of seven materials was investigated. Sustained load tests were conducted at 49 C (120 F) temperature with thin gauge tensile specimens having a semi-elliptical surface flaw. Alloys included aluminum 1100, 3003, 5086 and 6061; corrosion resistant steel types A286 and 347; and titanium 6Al-4V. The configurations tested with precracked flaws exposed to MON-1 were: parent or base metal, center weld, and heat affected zone. It was concluded that this chloride level in MON-1 does not affect the stress corrosion, crack growth properties of these alloys after 1000 hour exposure duration under high stresses.
Hydrologic data for the southwest subsurface-injection test site, St. Petersburg, Florida
Hickey, John J.; Spechler, R.M.
1978-01-01
Three injection wells and nine observation wells were constructed at the Southwest St. Petersburg, Fla., site to determine feasibility of injecting wastewater treatment plant effluent into permeable zones containing saline water. Two withdrawal tests and one injection test were performed. Both withdrawal tests ran for about 3 days; one discharging 650 gallons per minute, and the other discharging 6,490 gallons per minute. The injection test was run in one well for 91.1 days at an average rate of 2,830 gallons per minute. Injection well pressure reached a maximum of 48.1 pounds per square inch near the end of the test. Rhodamine WT was used as a tracer during the injection test and was identified in three wells. Before the injection test, chloride concentration in a well 35 feet from the injection well, and in a well 733 feet distant, ranged from 19,000 to 21,000 milligrams per liter. At the end of the test, chloride concentration in one well was 1,800 milligrams per liter and 5,400 milligrams per liter in another. Eleven wells near the site were sampled before the test for water-quality analyses and chlorides ranged from 18 to 1,400 milligrams per liter. (Woodard-USGS)
Sodium chloride-esculin hydrolysis test for rapid identification of enterococci.
Qadri, S M; Flournoy, D J; Qadri, S G
1987-01-01
The ability of enterococci to cause severe disease in humans and their relative resistance to chemotherapeutic agents make it desirable to rapidly differentiate these organisms from other streptococci. We developed and evaluated a test that within 2 h distinguishes enterococci from other alpha-, beta-, or nonhemolytic streptococci in a buffered solution containing 0.2% esculin and 5% sodium chloride. All 239 strains of enterococci tested gave a positive reaction within 2 h, whereas 95 of 96 isolates of other streptococci remained negative at 4 h. PMID:3597753
Nowakowska, Danuta; Raszewski, Zbigniew; Ziętek, Marek; Saczko, Jolanta; Kulbacka, Julita; Więckiewicz, Włodzimierz
2018-02-01
The compatibility of chemical gingival margin displacement agents with polyether impression materials has not been determined. The aim of this study was to evaluate the setting time of polyether impression elastomers after contact with conventional and experimental gingival displacement agents. The study compared the setting time of two polyether impression materials: medium body (Impregum Penta Soft) and light body (Impregum Garant L DuoSoft) after contact with 10 gingival displacement agents, including 5 conventional astringents (10%, 20%, and 25% aluminum chloride, 25% aluminum sulfate, and 15.5% ferric sulfate) and 5 experimental adrenergics (0.1% and 0.01% HCl-epinephrine, 0.05% HCl-tetrahydrozoline, 0.05% HCl-oxymetazoline, and 10% HCl-phenylephrine). As many as 120 specimens (60 light body and 60 medium body) were mixed with 20 μl of each of 10 gingival displacement agents, and the time to achieve maximum viscosity was measured with a viscometer. The setting times of these specimens were compared with the control group of 12 specimens, which were polymerized without contact with the displacement agents. The experiments were performed in two environments: 23°C and 37°C (± 0.1°C). Individual and average polymerization time compatibility indices (PTCI) were calculated. Data were analyzed by 2-way ANOVA (α = 0.05). The evaluated chemical displacement agents from both groups changed the setting time of light- and medium-body PE. The negative individual PTCI values achieved astringent (20% aluminum chloride) with two PE in both temperature environments. The average PTCI values of the experimental displacement agents at laboratory and intraoral temperatures were significantly higher than the conventional agents. The present findings suggest that experimental retraction agents can be recommended clinically as gingival margin displacement agents with minimal effects on the setting time of medium- and light-body polyether impression materials; however, direct contact of chemical displacement agents and polyether impression materials can be avoided. © 2016 by the American College of Prosthodontists.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-04
... for Safety--Collateral Standard: Electromagnetic Compatibility--Requirements and Tests,'' and ASME A18.1 ``Safety Standard for Platform Lifts and Stairway Chair Lifts'') must validate electromagnetic...: Electromagnetic Compatibility--Requirements and Tests,'' and ASME A18.1 ``Safety Standard for Platform Lifts and...
NASA Astrophysics Data System (ADS)
Hoskins, Douglas; Snead, Robert
1988-05-01
This report details the results of an electromagnetic compatibility test on the SCI Systems Data Acquisition and Control Assembly (DACA). This assembly is an electronic processor which controls the central communication link from the Tethered Satellite System (TSS) to the Space Transportation System Orbiter Space Shuttle.
Permeation Properties and Pore Structure of Surface Layer of Fly Ash Concrete
Liu, Jun; Qiu, Qiwen; Xing, Feng; Pan, Dong
2014-01-01
This paper presents an experimental study on the nature of permeation properties and pore structure of concrete surface layers containing fly ash. Concretes containing different dosages of fly ash as a replacement for cement (15% and 30% by weight of total cement materials, respectively) were investigated. Concrete without any fly ash added was also employed as the reference specimen. Laboratory tests were conducted to determine the surface layer properties of concrete including chloride transport, apparent water permeability and pore structure. The results demonstrate that incorporation of fly ash, for the early test period, promotes the chloride ingress at the surface layer of concrete but substituting proportions of fly ash may have little impact on it. With the process of chloride immersion, the chloride concentration at the surface layer of concrete with or without fly ash was found to be nearly the same. In addition, it is suggested that the water permeability at the concrete surface area is closely related to the fly ash contents as well as the chloride exposure time. Pore structure was characterized by means of mercury intrusion porosimetry (MIP) test and the scanning electron microscopy (SEM) images. The modification of pore structure of concrete submersed in distilled water is determined by the pozzolanic reaction of fly ash and the calcium leaching effect. The pozzolanic reaction was more dominant at the immersion time of 180 days while the calcium leaching effect became more evident after 270 days. PMID:28788677
Potential of tin (IV) chloride for treatment in Alor Pongsu as stabilized landfill leachate
NASA Astrophysics Data System (ADS)
Zainal, Sharifah Farah Fariza Syed; Aziz, Hamidi Abdul
2017-10-01
Leachate production from landfilling contributes crucial pollutants to the environment. This study examined the potential of tin (IV) chloride as coagulant that involved charge neutralization and sweep flocculation mechanisms. The negative charge of leachate is neutralized by adding tin (IV) chloride as cationic coagulant which resulted precipitation and swept most of the colloids and dissolved solids that entrapped in the settling as hydrous oxide floc. Parameters such as suspended solid (SS) content, color, and chemical oxygen demand (COD) were analyzed using standard jar test procedures. The best condition was observed at pH 8, with removal efficiencies of 75.99 %, 99.29 % and 98.36 % for COD, SS, and color, respectively. At optimum dosage, tin (IV) chloride successfully removed 98.40 % for color, 99.54 % for SS and 71.53 % for COD. These results indicated the satisfactory performance of tin (IV) chloride. Hence, tin (IV) chloride is a potential coagulant for the treatment of Alor Pongsu Landfill leachate.
Fukuda, K; Matsushita, H; Sakabe, H; Takemoto, K
1981-10-01
The carcinogenicity of benzyl chloride (BYC), benzal chloride (BAC), benzotrichloride (BTC) and benzoyl chloride (BOC), which were suspected as causative agents of lung cancer and maxillary malignant lymphoma of workers employed in factories producing BOC, was examined by skin applications in female ICR mice. After rather high dose exposure, BTC exhibited leukemogenic and pulmonary tumorigenic activities as well as potent dermal carcinogenic activity. After administration of the chemicals at the dose of 2.3 microliter/animal, twice a week for 50 weeks, BTC induced 68% incidence of skin cancers and 58% incidence of pulmonary tumors (including 10% of lung carcinomas) within 399 days. Incidence of skin cancers was 58% for BAC, 15% for BYC and 10% for BOC within 560 days. Considering the extent of possible exposure of the workers to these chemicals in the working environment and the carcinogenic potency of the chemicals tested, it can be concluded that BTC was very probably responsible for causing the cancers seen int he workers employed in manufacturing BOC.
Development and critical evaluation of fluorescent chloride nanosensors.
Graefe, Anja; Stanca, Sarmiza E; Nietzsche, Sandor; Kubicova, Lenka; Beckert, Rainer; Biskup, Christoph; Mohr, Gerhard J
2008-09-01
In this study, we describe the preparation and evaluation of new fluorescent sensor nanoparticles for the ratiometric measurement of chloride concentrations. Both a chloride-sensitive dye (lucigenin) and a reference dye (sulforhodamine derivative) were incorporated into polyacrylamide nanoparticles via inverse microemulsion polymerization and investigated for their response to chloride ions in buffered suspension as well as in living cells. The fluorescence intensity of lucigenin reversibly decreased in the presence of chloride ions due to a collisional quenching process, which can be described with the Stern-Volmer equation. The determined Stern-Volmer constant K SV for the quenching of lucigenin incorporated into particles was found to be 53 M (-1) and is considerably smaller than the Stern-Volmer constant for quenching of free lucigenin ( K SV = 250 M (-1)) under the same conditions. To test the nanosensors in living cells, we incorporated them into Chinese hamster ovary cells and mouse fibroblasts by using the conventional lipofectamin technique and monitored the response to changing chloride concentrations in the cell.
DOT National Transportation Integrated Search
2011-07-01
Many entities currently use permeability specifications in portland cement concrete (PCC) pavements and structures. This project investigated the use of a surface resistivity device as an indication of concretes ability to resist chloride ion pene...
Pharmacological analysis of epithelial chloride secretion mechanisms in adult murine airways.
Gianotti, Ambra; Ferrera, Loretta; Philp, Amber R; Caci, Emanuela; Zegarra-Moran, Olga; Galietta, Luis J V; Flores, Carlos A
2016-06-15
Defective epithelial chloride secretion occurs in humans with cystic fibrosis (CF), a genetic defect due to loss of function of CFTR, a cAMP-activated chloride channel. In the airways, absence of an active CFTR causes a severe lung disease. In mice, genetic ablation of CFTR function does not result in similar lung pathology. This may be due to the expression of an alternative chloride channel which is activated by calcium. The most probable protein performing this function is TMEM16A, a calcium-activated chloride channel (CaCC). Our aim was to assess the relative contribution of CFTR and TMEM16A to chloride secretion in adult mouse trachea. For this purpose we tested pharmacological inhibitors of chloride channels in normal and CF mice. The amplitude of the cAMP-activated current was similar in both types of animals and was not affected by a selective CFTR inhibitor. In contrast, a CaCC inhibitor (CaCCinh-A01) strongly blocked the cAMP-activated current as well as the calcium-activated chloride secretion triggered by apical UTP. Although control experiments revealed that CaCCinh-A01 also shows inhibitory activity on CFTR, our results indicate that transepithelial chloride secretion in adult mouse trachea is independent of CFTR and that another channel, possibly TMEM16A, performs both cAMP- and calcium-activated chloride transport. The prevalent function of a non-CFTR channel may explain the absence of a defect in chloride transport in CF mice. Copyright © 2016. Published by Elsevier B.V.
Skin sterility after application of ethyl chloride spray.
Polishchuk, Daniil; Gehrmann, Robin; Tan, Virak
2012-01-18
Ethyl chloride topical anesthetic spray is labeled as nonsterile, yet it is widely used during injection procedures performed in an outpatient setting. The purpose of this study was to investigate the sterility of ethyl chloride topical anesthetic spray applied before an injection. Our a priori hypothesis was that application of the spray after the skin has been prepared would not alter the sterility of the injection site. We conducted a prospective, blinded, controlled study to assess the effect of ethyl chloride spray on skin sterility. Fifteen healthy adult subjects (age, twenty-three to sixty-one years) were prepared for mock injections into both shoulders and both knees, although no injection was actually performed. Three culture samples were obtained from each site on the skin: one before skin preparation with isopropyl alcohol, one after skin preparation and before application of ethyl chloride, and one after ethyl chloride had been sprayed on the site. In addition, the sterility of the ethyl chloride was tested directly by inoculating cultures with spray from the bottles. Growth occurred in 70% of the samples obtained before skin preparation, 3% of the samples obtained after skin preparation but before application of ethyl chloride, and 5% of the samples obtained after the injection site had been sprayed with ethyl chloride. The percentage of positive cultures did not increase significantly after application of ethyl chloride (p = 0.65). Spraying of ethyl chloride directly on agar plates resulted in growth on 13% of these plates compared with 11% of the control plates; this difference was also not significant (p = 0.80). Although ethyl chloride spray is not sterile, its application did not alter the sterility of the injection sites in the shoulder and knee.
The use of sodium bicarbonate in oral hygiene products and practice.
Newbrun, E
1996-01-01
Early dentifrices contained natural ingredients, mostly in coarse particle form, and were quite abrasive. Salts, either sodium chloride, sodium bicarbonate, or a mixture of both, have also been used for tooth cleaning because of their ready availability and low cost. Because of both their relatively low intrinsic hardness and their high solubility, another advantage is low abrasivity. Their biggest disadvantage is a salty, unpalatable taste. Many modern dentifrices that contain sodium bicarbonate, either as the sole abrasive or one of several, disguise the saltiness with flavoring and sweetening agents. An almost inverse relationship exists between the percentage of baking soda in a dentifrice and its abrasivity. Sodium bicarbonate has no anticaries activity per se but is compatible with fluoride. In high concentrations, sodium bicarbonate is bactericidal against most periodontal pathogens. Most clinical studies have not found significant differences in periodontal response to baking soda as compared with other commercial dentifrices, probably because of its rapid clearance from the gingival sulcus. Sodium bicarbonate may not be the "magic bullet" for curing dental diseases, but its safety (if ingested), low abrasivity, low cost, and compatibility with fluoride make it a consummate dentifrice ingredient.
The use of sodium bicarbonate in oral hygiene products and practice.
Newbrun, E
1997-01-01
Early dentifrices contained natural ingredients, mostly in coarse particle form, and were quite abrasive. Salts, either sodium chloride, sodium bicarbonate, or a mixture of both, have also been used for tooth cleaning because of their ready availability and low cost. Because of both their relatively low intrinsic hardness and their high solubility, another advantage is low abrasivity. Their biggest disadvantage is a salty, unpalatable taste. Many modern dentifrices that contain sodium bicarbonate, either as the sole abrasive or one of several, disguise the saltiness with flavoring and sweetening agents. An almost inverse relationship exists between the percentage of baking soda in a dentifrice and its abrasivity. Sodium bicarbonate has no anticaries activity per se but is compatible with fluoride. In high concentrations, sodium bicarbonate is bactericidal against most periodontal pathogens. Most clinical studies have not found significant differences in periodontal response to baking soda as compared with other commercial dentifrices, probably because of its rapid clearance from the gingival sulcus. Sodium bicarbonate may not be the "magic bullet" for curing dental diseases, but its safety (if ingested), low abrasivity, low cost, and compatibility with fluoride make it a consummate dentifrice ingredient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harper, M.
A sorbent to be used for air sampling must meet certain performance criteria including sample background, capacity, stability, and recovery. Anasorb{sup R} 747 is a proprietary 20/40 mesh beaded active carbon prepared from raw materials with a very low ash content in a process which creates a regular pore structure. The background is very low for both inorganic and organic species, and the surface is more inert and less hydrophilic than coconut charcoal, while capacity is similar. The low catalytic activity of the surface means samples of many reactive compounds remain stable for longer periods. The sorbent is compatible withmore » most solvent systems in use (e.g. carbon disulfide, methylene chloride, methanol, dimethyformamide). Anasorb 747 can be coated with chemicals for efficient adsorption of inorganic gases, which can be analyzed at very low levels because of low background interference. A large number of validated sampling methods use Anasorb 747, including methods from OSHA and NIOSH, corporate industrial hygiene laboratories, various branches of the EPA, and international agencies. These methods refer to around fifty different gases and vapors. Although this sorbent is not compatible with some compounds (e.g. low molecular weight aldehydes) it is quite close to being of universal application.« less
NASA Astrophysics Data System (ADS)
Schütz, F.; Scheurell, K.; Scholz, G.; Kemnitz, E.
2016-09-01
Porous antireflective thin films, prepared of nanoscopic MgF2 sols, exhibit a low refraction index and are useful for various optical applications. Due to their porosity, film stability and durability suffer from mechanical abrasion and water solubility, respectively. Hence, we present approaches of improved mechanical stability of MgF2 layers induced by chloride addition. Antireflective (AR) films were produced by dip-coating followed by thermal treatment. Afterwards, film stability and environmental durability was strained by crockmeter and water stability tests, respectively. In comparison to films prepared from chloride-free MgF2 sols, chloride mingled sols form coatings with increased mechanical stability and a lower solubility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other..., App. B Appendix B to Part 173—Procedure for Testing Chemical Compatibility and Rate of Permeation in... °C. (64 °F.) b. Test Method 2: 28 days at a temperature no lower than 50 °C. (122 °F.) c. Test Method...
Non-dystrophic myotonia: prospective study of objective and patient reported outcomes.
Trivedi, Jaya R; Bundy, Brian; Statland, Jeffrey; Salajegheh, Mohammad; Rayan, Dipa Raja; Venance, Shannon L; Wang, Yunxia; Fialho, Doreen; Matthews, Emma; Cleland, James; Gorham, Nina; Herbelin, Laura; Cannon, Stephen; Amato, Anthony; Griggs, Robert C; Hanna, Michael G; Barohn, Richard J
2013-07-01
Non-dystrophic myotonias are rare diseases caused by mutations in skeletal muscle chloride and sodium ion channels with considerable phenotypic overlap between diseases. Few prospective studies have evaluated the sensitivity of symptoms and signs of myotonia in a large cohort of patients. We performed a prospective observational study of 95 participants with definite or clinically suspected non-dystrophic myotonia recruited from six sites in the USA, UK and Canada between March 2006 and March 2009. We used the common infrastructure and data elements provided by the NIH-funded Rare Disease Clinical Research Network. Outcomes included a standardized symptom interview and physical exam; the Short Form-36 and the Individualized Neuromuscular Quality of Life instruments; electrophysiological short and prolonged exercise tests; manual muscle testing; and a modified get-up-and-go test. Thirty-two participants had chloride channel mutations, 34 had sodium channel mutations, nine had myotonic dystrophy type 2, one had myotonic dystrophy type 1, and 17 had no identified mutation. Phenotype comparisons were restricted to those with sodium channel mutations, chloride channel mutations, and myotonic dystrophy type 2. Muscle stiffness was the most prominent symptom overall, seen in 66.7% to 100% of participants. In comparison with chloride channel mutations, participants with sodium mutations had an earlier age of onset of stiffness (5 years versus 10 years), frequent eye closure myotonia (73.5% versus 25%), more impairment on the Individualized Neuromuscular Quality of Life summary score (20.0 versus 9.44), and paradoxical eye closure myotonia (50% versus 0%). Handgrip myotonia was seen in three-quarters of participants, with warm up of myotonia in 75% chloride channel mutations, but also 35.3% of sodium channel mutations. The short exercise test showed ≥10% decrement in the compound muscle action potential amplitude in 59.3% of chloride channel participants compared with 27.6% of sodium channel participants, which increased post-cooling to 57.6% in sodium channel mutations. In evaluation of patients with clinical and electrical myotonia, despite considerable phenotypic overlap, the presence of eye closure myotonia, paradoxical myotonia, and an increase in short exercise test sensitivity post-cooling suggest sodium channel mutations. Outcomes designed to measure stiffness or the electrophysiological correlates of stiffness may prove useful for future clinical trials, regardless of underlying mutation, and include patient-reported stiffness, bedside manoeuvres to evaluate myotonia, muscle specific quality of life instruments and short exercise testing.
... test is used to confirm these results. Normal Results Normal results include: A sweat chloride test result ... edema) can affect the test results. What Abnormal Results Mean An abnormal test may mean that the ...
Dhayat, Nasser A; Gradwell, Michael W; Pathare, Ganesh; Anderegg, Manuel; Schneider, Lisa; Luethi, David; Mattmann, Cedric; Moe, Orson W; Vogt, Bruno; Fuster, Daniel G
2017-09-07
Incomplete distal renal tubular acidosis is a well known cause of calcareous nephrolithiasis but the prevalence is unknown, mostly due to lack of accepted diagnostic tests and criteria. The ammonium chloride test is considered as gold standard for the diagnosis of incomplete distal renal tubular acidosis, but the furosemide/fludrocortisone test was recently proposed as an alternative. Because of the lack of rigorous comparative studies, the validity of the furosemide/fludrocortisone test in stone formers remains unknown. In addition, the performance of conventional, nonprovocative parameters in predicting incomplete distal renal tubular acidosis has not been studied. We conducted a prospective study in an unselected cohort of 170 stone formers that underwent sequential ammonium chloride and furosemide/fludrocortisone testing. Using the ammonium chloride test as gold standard, the prevalence of incomplete distal renal tubular acidosis was 8%. Sensitivity and specificity of the furosemide/fludrocortisone test were 77% and 85%, respectively, yielding a positive predictive value of 30% and a negative predictive value of 98%. Testing of several nonprovocative clinical parameters in the prediction of incomplete distal renal tubular acidosis revealed fasting morning urinary pH and plasma potassium as the most discriminative parameters. The combination of a fasting morning urinary threshold pH <5.3 with a plasma potassium threshold >3.8 mEq/L yielded a negative predictive value of 98% with a sensitivity of 85% and a specificity of 77% for the diagnosis of incomplete distal renal tubular acidosis. The furosemide/fludrocortisone test can be used for incomplete distal renal tubular acidosis screening in stone formers, but an abnormal furosemide/fludrocortisone test result needs confirmation by ammonium chloride testing. Our data furthermore indicate that incomplete distal renal tubular acidosis can reliably be excluded in stone formers by use of nonprovocative clinical parameters. Copyright © 2017 by the American Society of Nephrology.
Effect of salt on the response of birds to sucrose
Rogers, J.G.; Maller, O.
1973-01-01
The preference of male red-winged blackbirds for solutions of sucrose and sucrose with 0.03 M sodium chloride was tested, using a two-bottle choice test. Preliminary experiments demonstrated that the birds were indifferent to 0.03 M NaCl in water. Both control and experimental animals exhibited indifference to the solutions at the lowest concentration and aversion at the highest. The data suggest that the added sodium chloride makes the sucrose stimulus more discriminable.
Lee, Sang S; Hong, Dong K; Jeong, Nam J; Lee, Jeung H; Choi, Yun-Seok; Lee, Ai-Young; Lee, Cheol-Heon; Kim, Kea J; Park, Hae Y; Yang, Jun-Mo; Lee, Ga-Young; Lee, Joon; Eun, Hee C; Moon, Kee-Chan; Seo, Seong J; Hong, Chang K; Lee, Sang W; Choi, Hae Y; Lee, Jun Y
2012-08-01
As many new cosmetic products are introduced into the market, attention must be given to contact dermatitis, which is commonly caused by cosmetics. We investigate the prevalence of preservative allergy in 584 patients with suspected cosmetic contact dermatitis at 11 different hospitals. From January 2010 to March 2011, 584 patients at 11 hospital dermatology departments presented with cosmetic contact dermatitis symptoms. These patients were patch-tested for preservative allergens. An irritancy patch test performed on 30 control subjects using allergens of various concentrations showed high irritancy rates. Preservative hypersensitivity was detected in 41.1% of patients. Allergens with the highest positive test rates were benzalkonium chloride (12.1%), thimerosal (9.9%) and methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) (5.5%). Benzalkonium chloride and chlorphenesin had the highest irritancy rate based on an irritancy patch test performed using various concentrations. Seven of 30 normal subjects had a positive irritant patch reading with 0.1% benzalkonium chloride and eight of 30 normal subjects had a positive irritant patch reading at 4 days with 0.5% chlorphenesin in petrolatum. Although benzalkonium chloride was highly positive for skin reactions in our study, most reactions were probably irritation. MCI/MI and thimerosal showed highly positive allergy reactions in our study. The optimum concentration of chlorphenesin to avoid skin reactions is less than 0.5%. © 2012 Japanese Dermatological Association.
Effect of 10% Strontium Chloride and 5% Potassium Nitrate with Fluoride on Bleached Bovine Enamel.
Alencar, Cristiane de Melo; Pedrinha, Victor Feliz; Araújo, Jesuína Lamartine Nogueira; Esteves, Renata Antunes; Silva da Silveira, Ana Daniela; Silva, Cecy Martins
2017-01-01
Dental whitening has been increasingly sought out to improve dental aesthetics, but may cause chemical and morphological changes in dental enamel surfaces. This study evaluated in vitro the effect of 10% strontium chloride and 5% potassium nitrate with fluoride on bovine enamel, through tristimulus colorimetry, Knoop microhardness (KHN), and roughness after bleaching with 35% hydrogen peroxide (HP). The specimens were divided into three groups (n=15): GControl received bleaching treatment with 35% HP; GNitrate received bleaching with 35% HP followed by the application of 5% potassium nitrate with 2% sodium fluoride; and GStrontium received bleaching with 35% HP followed by the application of 10% strontium chloride on the enamel. Next, five specimens of each experimental group were subjected to KHN and tristimulus colorimetry tests, and 10 specimens were subjected to surface roughness (SR) tests. The values obtained for the different groups were compared through analysis of variance (ANOVA) followed by a post-hoc Tukey-Kramer test in addition to Student's T-test for paired data. In the intergroup comparison, KHN final differed statistically ( p <0.05). The mean SR final of the experimental groups differed statistically from the GControl group ( p <0.05). In addition, the groups did not differ in color variation ( p >0.05). 10% strontium chloride and 5% potassium nitrate combined with 2% fluoride downplayed morphological changes to the enamel, without interfering with the effectiveness of the bleaching process.
DOT National Transportation Integrated Search
2011-07-01
This project investigated the use of a surface resistivity device as an indication of concretes ability to resist chloride ion penetration for use in quality assurance (QA) and acceptance of high performance concrete (HPC). : The objectives of thi...
40 CFR 63.7505 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance with the applicable emission limit for hydrogen chloride or mercury using fuel analysis if the..., fuel analysis, or continuous monitoring systems (CMS), including a continuous emission monitoring..., you must demonstrate compliance for hydrogen chloride or mercury using performance testing, if subject...
Effects of chloride ions on corrosion of ductile iron and carbon steel in soil environments.
Song, Yarong; Jiang, Guangming; Chen, Ying; Zhao, Peng; Tian, Yimei
2017-07-31
Chloride is reported to play a significant role in corrosion reactions, products and kinetics of ferrous metals. To enhance the understanding of the effects of soil environments, especially the saline soils with high levels of chloride, on the corrosion of ductile iron and carbon steel, a 3-month corrosion test was carried out by exposing ferrous metals to soils of six chloride concentrations. The surface morphology, rust compositions and corrosion kinetics were comprehensively studied by visual observation, scanning electron microscopy (SEM), X-Ray diffraction (XRD), weight loss, pit depth measurement, linear polarization and electrochemical impedance spectroscopy (EIS) measurements. It showed that chloride ions influenced the characteristics and compositions of rust layers by diverting and participating in corrosion reactions. α-FeOOH, γ-FeOOH and iron oxides were major corrosion products, while β-Fe 8 O 8 (OH) 8 Cl 1.35 rather than β-FeOOH was formed when high chloride concentrations were provided. Chloride also suppressed the decreasing of corrosion rates, whereas increased the difficulty in the diffusion process by thickening the rust layers and transforming the rust compositions. Carbon steel is more susceptible to chloride attacks than ductile iron. The corrosion kinetics of ductile iron and carbon steel corresponded with the probabilistic and bilinear model respectively.
Incorporating evolutionary insights to improve ecotoxicology for freshwater species
Brady, Steven P.; Richardson, Jonathan L.; Kunz, Bethany K.
2017-01-01
Ecotoxicological studies have provided extensive insights into the lethal and sublethal effects of environmental contaminants. These insights are critical for environmental regulatory frameworks, which rely on knowledge of toxicity for developing policies to manage contaminants. While varied approaches have been applied to ecotoxicological questions, perspectives related to the evolutionary history of focal species or populations have received little consideration. Here, we evaluate chloride toxicity from the perspectives of both macroevolution and contemporary evolution. First, by mapping chloride toxicity values derived from the literature onto a phylogeny of macroinvertebrates, fish, and amphibians, we tested whether macroevolutionary relationships across species and taxa are predictive of chloride tolerance. Next, we conducted chloride exposure tests for two amphibian species to assess whether potential contemporary evolutionary change associated with environmental chloride contamination influences chloride tolerance across local populations. We show that explicitly evaluating both macroevolution and contemporary evolution can provide important and even qualitatively different insights from those obtained via traditional ecotoxicological studies. While macroevolutionary perspectives can help forecast toxicological end points for species with untested sensitivities, contemporary evolutionary perspectives demonstrate the need to consider the environmental context of exposed populations when measuring toxicity. Accounting for divergence among populations of interest can provide more accurate and relevant information related to the sensitivity of populations that may be evolving in response to selection from contaminant exposure. Our data show that approaches accounting for and specifically examining variation among natural populations should become standard practice in ecotoxicology.
Development of a Paper Strip Test for Detection of Niacin Produced by Mycobacteria
Young, William D.; Maslansky, Alvin; Lefar, Morton S.; Kronish, Donald P.
1970-01-01
The development of a reagent-impregnated paper strip test for niacin is described. The test system is based on the formation of cyanogen chloride by the reaction of chloramine-T and potassium thiocyanate in the presence of citric acid. Rupture of the pyridine ring of niacin by cyanogen chloride yields γ-carboxy glutaconic aldehyde and coupling with a primary aromatic amine produces a yellow color. Sensitivity to niacin, both in known solutions and from extracts of 378 clinical mycobacteria isolates, equalled or exceeded that of other methods for detection of niacin. Correlation with other tests for mycobacterial niacin was excellent. PMID:4321713
NASA Technical Reports Server (NTRS)
Harper, Susan A.; Juarez, Alfredo; Peralta, Stephen F.; Stoltzfus, Joel; Arpin, Christina Pina; Beeson, Harold D.
2016-01-01
Solvents used to clean oxygen system components must be assessed for oxygen compatibility, as incompatible residue or fluid inadvertently left behind within an oxygen system can pose a flammability risk. The most recent approach focused on solvent ignition susceptibility to assess the flammability risk associated with these materials. Previous evaluations included Ambient Pressure Liquid Oxygen (LOX) Mechanical Impact Testing (ASTM G86) and Autogenous Ignition Temperature (AIT) Testing (ASTM G72). The goal in this approach was to identify a solvent material that was not flammable in oxygen. As environmental policies restrict the available options of acceptable solvents, it has proven difficult to identify one that is not flammable in oxygen. A more rigorous oxygen compatibility approach is needed in an effort to select a new solvent for NASA applications. NASA White Sands Test Facility proposed an approach that acknowledges oxygen flammability, yet selects solvent materials based on their relative oxygen compatibility ranking, similar to that described in ASTM G63-99. Solvents are selected based on their ranking with respect to minimal ignition susceptibility, damage and propagation potential, as well as their relative ranking when compared with other solvent materials that are successfully used in oxygen systems. Test methods used in this approach included ASTM G86 (Ambient Pressure LOX Mechanical Impact Testing and Pressurized Gaseous Oxygen (GOX) Mechanical Impact Testing), ASTM G72 (AIT Testing), and ASTM D240 (Heat of Combustion (HOC) Testing). Only four solvents were tested through the full battery of tests for evaluation of oxygen compatibility: AK-225G as a baseline comparison, Solstice PF, L-14780, and Vertrel MCA. Baseline solvent AK-225G exhibited the lowest HOC and highest AIT of solvents tested. Nonetheless, Solstice PF, L-14780, and Vertrel MCA HOCs all fell well within the range of properties that are associated with proven oxygen system materials. Tested AITs for these solvents fell only slightly lower than the AIT for the proven AK-225G solvent. Based on these comparisons in which solvents exhibited properties within those ranges seen with proven oxygen system materials, it is believed that Solstice PF, L-14780, and Vertrel MCA would perform well with respect to oxygen compatibility.
ERIC Educational Resources Information Center
Chang, J. C.; And Others
1986-01-01
Discusses a new program at the University of Michigan in hazardous waste management. Describes a laboratory demonstration that deals with the reactivity and potential violence of several reactions that may be encountered on a hazardous waste site. Provides criteria for selecting particular compatibility testing methods. (TW)
Myers, Alan L; Zhang, Yang-Ping; Kawedia, Jitesh D; Trinh, Van A; Tran, Huyentran; Smith, Judith A; Kramer, Mark A
2016-02-01
Carboplatin is a platinum-containing compound with efficacy against various malignancies. The physico-chemical stability of carboplatin in dextrose 5% water (D5W) has been thoroughly studied; however, there is a paucity of stability data in clinically relevant 0.9% sodium chloride infusion solutions. The manufacturer's limited stability data in sodium chloride solutions hampers the flexibility of carboplatin usage in oncology patients. Hence, the purpose of this study is to determine the physical and chemical stability of carboplatin-sodium chloride intravenous solutions under different storage conditions. The physico-chemical stability of 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL carboplatin-sodium chloride solutions prepared in polyvinyl chloride bags was determined following storage at room temperature under ambient fluorescent light and under refrigeration in the dark. Concentrations of carboplatin were measured at predetermined time points up to seven days using a stability-indicating high-performance liquid chromatography method. All tested solutions were found physically stable for at least seven days. The greatest chemical stability was observed under refrigerated storage conditions. At 4℃, all tested solutions were found chemically stable for at least seven days, with nominal losses of ≤6%. Following storage at room temperature exposed to normal fluorescent light, the chemical stability of 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL solutions was three days, five days, and seven days, respectively. The extended physico-chemical stability of carboplatin prepared in sodium chloride reported herein permits advance preparation of these admixtures, facilitating pharmacy utility and operations. Since no antibacterial preservative is contained within these carboplatin solutions, we recommend storage, when prepared under specified aseptic conditions, no greater than 24 h at room temperature or three days under refrigeration. © The Author(s) 2014.
Hu, Yue; Boyer, Treavor H
2017-05-15
The application of bicarbonate-form anion exchange resin and sodium bicarbonate salt for resin regeneration was investigated in this research is to reduce chloride ion release during treatment and the disposal burden of sodium chloride regeneration solution when using traditional chloride-form ion exchange (IX). The target contaminant in this research was dissolved organic carbon (DOC). The performance evaluation was conducted in a completely mixed flow reactor (CMFR) IX configuration. A process model that integrated treatment and regeneration was investigated based on the characteristics of configuration. The kinetic and equilibrium experiments were performed to obtain required parameters for the process model. The pilot plant tests were conducted to validate the model as well as provide practical understanding on operation. The DOC concentration predicted by the process model responded to the change of salt concentration in the solution, and showed a good agreement with pilot plant data with less than 10% difference in terms of percentage removal. Both model predictions and pilot plant tests showed over 60% DOC removal by bicarbonate-form resin for treatment and sodium bicarbonate for regeneration, which was comparable to chloride-form resin for treatment and sodium chloride for regeneration. Lastly, the DOC removal was improved by using higher salt concentration for regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.
Assessment of ground-water contamination in the alluvial aquifer near West Point, Kentucky
Lyverse, M.A.; Unthank, M.D.
1988-01-01
Well inventories, water level measurements, groundwater quality samples, surface geophysical techniques (specifically, electromagnetic techniques), and test drilling were used to investigate the extent and sources of groundwater contamination in the alluvial aquifer near West Point, Kentucky. This aquifer serves as the principal source of drinking water for over 50,000 people. Groundwater flow in the alluvial aquifer is generally unconfined and moves in a northerly direction toward the Ohio River. Two large public supply well fields and numerous domestic wells are located in this natural flow path. High concentrations of chloride in groundwater have resulted in the abandonment of several public supply wells in the West Point areas. Chloride concentrations in water samples collected for this study were as high as 11,000 mg/L. Electromagnetic techniques indicated and test drilling later confirmed that the source of chloride in well waters was probably improperly plugged or unplugged, abandoned oil and gas exploration wells. The potential for chloride contamination of wells exists in the study area and is related to proximity to improperly abandoned oil and gas exploration wells and to gradients established by drawdowns associated with pumped wells. Periodic use of surface geophysical methods, in combination with added observation wells , could be used to monitor significant changes in groundwater quality related to chloride contamination. (USGS)
The compatibility of consumer DLP projectors with time-sequential stereoscopic 3D visualisation
NASA Astrophysics Data System (ADS)
Woods, Andrew J.; Rourke, Tegan
2007-02-01
A range of advertised "Stereo-Ready" DLP projectors are now available in the market which allow high-quality flickerfree stereoscopic 3D visualization using the time-sequential stereoscopic display method. The ability to use a single projector for stereoscopic viewing offers a range of advantages, including extremely good stereoscopic alignment, and in some cases, portability. It has also recently become known that some consumer DLP projectors can be used for timesequential stereoscopic visualization, however it was not well understood which projectors are compatible and incompatible, what display modes (frequency and resolution) are compatible, and what stereoscopic display quality attributes are important. We conducted a study to test a wide range of projectors for stereoscopic compatibility. This paper reports on the testing of 45 consumer DLP projectors of widely different specifications (brand, resolution, brightness, etc). The projectors were tested for stereoscopic compatibility with various video formats (PAL, NTSC, 480P, 576P, and various VGA resolutions) and video input connections (composite, SVideo, component, and VGA). Fifteen projectors were found to work well at up to 85Hz stereo in VGA mode. Twenty three projectors would work at 60Hz stereo in VGA mode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pennington, J.C.; Theriot, E.A.
1983-06-01
A formulation of the fungus Cercospora rodmanii Conway has been produced, as a biocontrol of waterhyacinth (Eichhornia crassipes (Mart.) Solms.). To ensure the most efficient germination of the formulation, 12 potential enhancing agents were tested for addition during the spray application. The agents were aspartic acid, glucose, glutamic acid, gum xanthan, nutrient agar, Ortho X-77 Spreader, Tween 20, Tween 60, Tween 80, sodium alginate, Super Slupper, and yeast extract. Compatibility of test agents and combinations of test agents with two lots of the formulation was determined in the laboratory. All combinations of test agents were compatible with both lots ofmore » the C. rodmanii formulation. The C. rodmanii formulation was sprayed with test agents on waterhyacinth pseudolaminae. Damage was monitored each week for 8 weeks by assigning a disease index to each original and new pseudolaminae. No spots having characteristics suggestive of C. rodmanii infection were observed at any time during the study. Lack of infectivity could be remedied by isolating a virulent strain of C. rodmanii from the field. Agents determined to be compatible in this study could then be reexamined for enhancing infectivity on a virulent C. rodmanii formulation. 14 references, 2 figures, 5 tables.« less
Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.
2003-01-01
During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.
Landmeyer, J.E.; Bradley, P.M.
1998-01-01
Test well BFT-2055 was drilled through the entire thickness of Coastal Plain sediments beneath central Hilton Head Island, South Carolina, and terminated in bedrock at a depth of 3833 feet. The well was drilled to evaluate the hydraulic properties of the Cretaceous formations beneath Hilton Head Island as a potential source of supplemental water to supplies currently withdrawn from the Upper Floridan aquifer. The intervals tested include sediments of the Cape Fear and Middendorf Formations. Results from aquifer tests indicate that the transmissivity of the formations screened ranges from 1300 to 3000 feet squared per day and an average hydraulic conductivity of about 15 feet per day. Formation-fluid pressure tests indicate that the potential exists for upward ground-water flow from higher fluid pressures in the deeper Cape Fear and Middendorf Formations to lower fluid pressures in the Black Creek Formation and shallower units. A flowmeter test indicated that greater than 75 percent of the natural, unpumped flow in the well is from the screened intervals no deeper than 3100 feet. Water-chemistry analyses indicate that the water sampled from the Middendorf and Cape Fear has about 1450 milligrams per liter dissolved solids, 310 to 1000 milligrams per liter sodium, and 144 to 1600 milligrams per liter chloride. Because these chloride concentrations would render water pumped from these aquifers as nonpotable, it is unlikely that these aquifers will be used as a supplemental source of water for island residents without some form of pretreatment. Similar chloride concentrations are present in some wells in the Upper Floridan aquifer adjacent to Port Royal Sound, and these chloride concentrations were the primary reason for drilling the test well in the Cretaceous formations as a possible source of more potable water.
Harris, Michael R; Li, Qifang; Lian, Yajing; Xiao, Jun; Londregan, Allyn T
2017-05-05
Compounds that contain the 1-heteroaryl-3-azabicyclo[3.1.0]hexane architecture are of particular interest to the pharmaceutical industry yet remain a challenge to synthesize. We report herein an expedient and modular approach to the synthesis of 1-heteroaryl-3-azabicyclo[3.1.0]hexanes by Suzuki-Miyaura and Chan-Evans-Lam coupling reactions of tertiary trifluoroborate salts. Our Suzuki-Miyaura cross-coupling protocol is compatible with a broad range of aryl and heteroaryl bromides and chlorides. The unprecedented Chan-Evans-Lam coupling of tertiary trifluoroborates allows the facile construction of 1-heteroaryl-3-azabicyclo[3.1.0]hexanes containing C-tertiary arylamines at the ring juncture.
A low volume 3D-printed temperature-controllable cuvette for UV visible spectroscopy.
Pisaruka, Jelena; Dymond, Marcus K
2016-10-01
We report the fabrication of a 3D-printed water-heated cuvette that fits into a standard UV visible spectrophotometer. Full 3D-printable designs are provided and 3D-printing conditions have been optimised to provide options to print the cuvette in either acrylonitrile butadiene styrene or polylactic acid polymers, extending the range of solvents that are compatible with the design. We demonstrate the efficacy of the cuvette by determining the critical micelle concentration of sodium dodecyl sulphate at 40 °C, the molar extinction coefficients of cobalt nitrate and dsDNA and by reproducing the thermochromic UV visible spectrum of a mixture of cobalt chloride, water and propan-2-ol. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chandramohan, S.; Seo, Tae Hoon; Janardhanam, V.; Hong, Chang-Hee; Suh, Eun-Kyung
2017-10-01
Charge transfer doping is a renowned route to modify the electrical and electronic properties of graphene. Understanding the stability of potentially important charge-transfer materials for graphene doping is a crucial first step. Here we present a systematic comparison on the doping efficiency and stability of single layer graphene using molybdenum trioxide (MoO3), gold chloride (AuCl3), and bis(trifluoromethanesulfonyl)amide (TFSA). Chemical dopants proved to be very effective, but MoO3 offers better thermal stability and device fabrication compatibility. Single layer graphene films with sheet resistance values between 100 and 200 ohm/square were consistently produced by implementing a two-step growth followed by doping without compromising the optical transmittance.
Bacterial Compatibility in Combined Inoculations Enhances the Growth of Potato Seedlings.
Santiago, Christine D; Yagi, Shogo; Ijima, Motoaki; Nashimoto, Tomoya; Sawada, Maki; Ikeda, Seishi; Asano, Kenji; Orikasa, Yoshitake; Ohwada, Takuji
2017-03-31
The compatibility of strains is crucial for formulating bioinoculants that promote plant growth. We herein assessed the compatibility of four potential bioinoculants isolated from potato roots and tubers (Sphingomonas sp. T168, Streptomyces sp. R170, Streptomyces sp. R181, and Methylibium sp. R182) that were co-inoculated in order to improve plant growth. We screened these strains using biochemical tests, and the results obtained showed that R170 had the highest potential as a bioinoculant, as indicated by its significant ability to produce plant growth-promoting substances, its higher tolerance against NaCl (2%) and AlCl 3 (0.01%), and growth in a wider range of pH values (5.0-10.0) than the other three strains. Therefore, the compatibility of R170 with other strains was tested in combined inoculations, and the results showed that the co-inoculation of R170 with T168 or R182 synergistically increased plant weight over un-inoculated controls, indicating the compatibility of strains based on the increased production of plant growth promoters such as indole-3-acetic acid (IAA) and siderophores as well as co-localization on roots. However, a parallel test using strain R181, which is the same Streptomyces genus as R170, showed incompatibility with T168 and R182, as revealed by weaker plant growth promotion and a lack of co-localization. Collectively, our results suggest that compatibility among bacterial inoculants is important for efficient plant growth promotion, and that R170 has potential as a useful bioinoculant, particularly in combined inoculations that contain compatible bacteria.
Contact allergic gastritis: an underdiagnosed entity?
Pföhler, Claudia; Körner, Rebecca; Vogt, Thomas; Müller, Cornelia S L
2012-01-01
Only a few cases of contact allergic gastritis in patients with nickel allergy have been reported. We report a case of probable contact-allergic gastritis in a 46-year-old woman. Clinical examination revealed lichenoid mucosal lesions of the gums adjacent to bridges and crowns that had been implanted several weeks back. Since implantation, the patient had suffered from gastrointestinal complaints (including stomach pain). Gastroscopy showed eosinophilic gastritis. Patch testing done under the diagnosis of contact allergic stomatitis showed positive reactions to: gold sodium thiosulphate; manganese (II) chloride; nickel (II) sulphate; palladium chloride; vanadium (III) chloride and zirconium (IV) chloride. The crowns and bridge contained gold, palladium and zirconium chloride, hence they were replaced by titan-based dentition. Shortly after replacing the artificial dentition, all gastrointestinal symptoms resolved spontaneously without further treatment. Delayed-type allergy against the components of artificial dentition seemed to be the cause of gastritis. PMID:23192576
A novel method for improving cerussite sulfidization
NASA Astrophysics Data System (ADS)
Feng, Qi-cheng; Wen, Shu-ming; Zhao, Wen-juan; Cao, Qin-bo; Lü, Chao
2016-06-01
Evaluation of flotation behavior, solution measurements, and surface analyses were performed to investigate the effects of chloride ion addition on the sulfidization of cerussite in this study. Micro-flotation tests indicate that the addition of chloride ions prior to sulfidization can significantly increase the flotation recovery of cerussite, which is attributed to the formation of more lead sulfide species on the mineral surface. Solution measurement results suggest that the addition of chloride ions prior to sulfidization induces the transformation of more sulfide ions from pulp solution onto the mineral surface by the formation of more lead sulfide species. X-ray diffraction and energy-dispersive spectroscopy indicate that more lead sulfide species form on the mineral surface when chloride ions are added prior to sulfidization. These results demonstrate that the addition of chloride ions prior to sulfidization can significantly improve the sulfidization of cerussite, thereby enhancing the flotation performance.
Corrosion sensor for monitoring the service condition of chloride-contaminated cement mortar.
Lu, Shuang; Ba, Heng-Jing
2010-01-01
A corrosion sensor for monitoring the corrosion state of cover mortar was developed. The sensor was tested in cement mortar, with and without the addition of chloride to simulate the adverse effects of chloride-contaminated environmental conditions on concrete structures. In brief, a linear polarization resistance method combined with an embeddable reference electrode was utilized to measure the polarization resistance (Rp) using built-in sensor electrodes. Subsequently, electrochemical impedance spectroscopy in the frequency range of 1 kHz to 50 kHz was used to obtain the cement mortar resistance (Rs). The results show that the polarization resistance is related to the chloride content and Rs; ln (Rp) is linearly related to the Rs values in mortar without added chloride. The relationships observed between the Rp of the steel anodes and the resistance of the surrounding cement mortar measured by the corrosion sensor confirms that Rs can indicate the corrosion state of concrete structures.
Cartwright, C A; McRoberts, J A; Mandel, K G; Dharmsathaphorn, K
1985-01-01
Vasoactive intestinal polypeptide (VIP) and the calcium ionophore A23187 caused dose-dependent changes in the potential difference and the short circuit current (Isc) across confluent T84 cell monolayers mounted in modified Ussing chambers. Both VIP and A23187 stimulated net chloride secretion without altering sodium transport. Net chloride secretion accounted for the increase in Isc. When A23187 was tested in combination with VIP, net chloride secretion was significantly greater than predicted from the calculated sum of their individual responses indicating a synergistic effect. VIP increased cellular cyclic AMP (cAMP) production in a dose-dependent manner, whereas A23187 had no effect on cellular cAMP. We then determined whether VIP and A23187 activated different transport pathways. Earlier studies suggest that VIP activates a basolaterally localized, barium-sensitive potassium channel as well as an apically localized chloride conductance pathway. In this study, stimulation of basolateral membrane potassium efflux by A23187 was documented by preloading the monolayers with 86Rb+. Stimulation of potassium efflux by A23187 was additive to the VIP-stimulated potassium efflux. By itself, 0.3 microM A23187 did not alter transepithelial chloride permeability, and its stimulation of basolateral membrane potassium efflux caused only a relatively small amount of chloride secretion. However, in the presence of an increased transepithelial chloride permeability induced by VIP, the effectiveness of A23187 on chloride secretion was greatly augmented. Our studies suggest that cAMP and calcium each activate basolateral potassium channels, but cAMP also activates an apically localized chloride channel. Synergism results from cooperative interaction of potassium channels and the chloride channel. PMID:2997291
NASA Astrophysics Data System (ADS)
Latimer, T. W.; Rinehart, G. H.
1992-05-01
This report covers progress on the Milliwatt Generator Project from April 1986 through March 1988. Activities included fuel processing and characterization, production of heat sources, fabrication of pressure-burst test units, compatibility studies, impact testing, and examination of surveillance units. The major task of the Los Alamos Milliwatt Generator Project is to fabricate MC2893A heat sources (4.0 W) for MC2730A radioisotope thermoelectric generators (RTG's) and MC3599 heat sources (4.5 W) for MC3500 RTG's. The MWG Project interfaces with the following contractors: Sandia National Laboratories, Albuquerque (designer); E.I. du Pont de Nemours and Co. (Inc.), Savannah River Plant (fuel); Monsanto Research Corporation, Mound Facility (metal hardware); and General Electric Company, Neutron Devices Department (RTG's). In addition to MWG fabrication activities, Los Alamos is involved in (1) fabrication of pressure-burst test units, (2) compatibility testing and evaluation, (3) examination of surveillance units, and (4) impact testing and subsequent examination of compatibility and surveillance units.
Active lithium chloride cell for spacecraft power
NASA Technical Reports Server (NTRS)
Fleischmann, C. W.; Horning, R. J.
1988-01-01
An active thionyl chloride high rate battery is under development for spacecraft operations. It is a 540kC (150 Ah) battery capable of pulses up to 75A. This paper describes the design and initial test data on a 'state-of-the-art' cell that has been selected to be the baseline for the prototype cell for that battery. Initial data indicate that the specification can be met with fresh cells. Data for stored cells and additional environmental test data are in the process of being developed.
Reid, Brian; Graue-Hernandez, Enrique O; Mannis, Mark J; Zhao, Min
2011-03-01
To measure electric current in human corneal wounds and test the feasibility of pharmacologically enhancing the current to promote corneal wound healing. Using a noninvasive vibrating probe, corneal electric current was measured before and after wounding of the epithelium of donated postmortem human corneas. The effects of drug aminophylline and chloride-free solution on wound current were also tested. Unwounded cornea had small outward currents (0.07 μA/cm²). Wounding increased the current more than 5 fold (0.41 μA/cm²). Monitoring the wound current over time showed that it seemed to be actively regulated and maintained above normal unwounded levels for at least 6 hours. The time course was similar to that previously measured in rat cornea. Drug treatment or chloride-free solution more than doubled the size of wound currents. Electric current at human corneal wounds can be significantly increased with aminophylline or chloride-free solution. Because corneal wound current directly correlates with wound healing rate, our results suggest a role for chloride-free and/or aminophylline eyedrops to enhance healing of damaged cornea in patients with reduced wound healing such as the elderly or diabetic patient. This novel approach offers bioelectric stimulation without electrodes and can be readily tested in patients.
Johnston, R.H.
1983-01-01
Hydrologic testing in an offshore oil well abandoned by Tenneco, Inc., determined the position of the saltwater-freshwater interface in Tertiary limestones underlying the Florida-Georgia continental shelf of the U.S.A. Previous drilling (JOIDES and U.S.G.S. AMCOR projects) established the existence of freshwater far offshore in this area. At the Tenneco well 55 mi. (???88 km) east of Fernandina Beach, Florida, drill-stem tests made in the interval 1050-1070 ft. (320-326 m) below sea level in the Ocala Limestone recovered a sample with a chloride concentration of 7000 mg l-1. Formation water probably is slightly fresher. Pressure-head measurements indicated equivalent freshwater heads of 24-29 ft. (7.3-8.8 m) above sea level. At the coast (Fernandina Beach), a relatively thin transition zone separating freshwater and saltwater occurs at a depth of 2100 ft. (640 m) below sea level. Fifty-five miles (???88 km) offshore, at the Tenneco well, the base of freshwater is ???1100 ft. (???335 m) below sea level. The difference in approximate depth to the freshwater-saltwater transition at these two locations suggests an interface with a very slight landward slope. Assuming the Hubbert interface equation applies here (because the interface and therefore freshwater flow lines are nearly horizontal) the equilibrium depth to the interface should be 40 times the freshwater head above sea level. Using present-day freshwater heads along the coast in the Hubbert equation results in depths to the interface of less than the observed 2100 ft. (640 m). Substituting predevelopment heads in the equation yields depths greater than 2100 ft. (640 m). Thus the interface appears to be in a transient position between the position that would be compatible with present-day heads and the position that would be compatible with predevelopment heads. This implies that some movement of the interface from the predevelopment position has occurred during the past hundred years. The implied movement is incompatible with the hypothesis that the freshwater occurring far offshore in this area is trapped water remaining since the Pleistocene Epoch. ?? 1982.
Compatibility tests of materials for a lithium-cooled space power reactor concept
NASA Technical Reports Server (NTRS)
Sinclair, J. H.
1973-01-01
Materials for a lithium-cooled space power reactor concept must be chemically compatible for up to 50,000 hr at high temperature. Capsule tests at 1040 C (1900 F) were made of material combinations of prime interest: T-111 in direct contact with uranium mononitride (UN), Un in vacuum separated from T-111 by tungsten wire, UN with various oxygen impurity levels enclosed in tungsten wire lithium-filled T-111 capsules, and TZM and lithium together in T-111 capsules. All combinations were compatible for over 2800 hr except for T-111 in direct contact with UN.
40 CFR 63.7555 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... hydrogen chloride emission rates. You can use the results from one fuel analysis for multiple boilers and... fuel input, or hydrogen chloride emission rate, for each boiler and process heater. (5) A copy of all... submitted, according to the requirements in § 63.10(b)(2)(xiv). (2) Records of performance tests, fuel...
40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2013 CFR
2013-07-01
... installed in each baghouse compartment or cell. For negative pressure or induced air fabric filters, the bag... test. (g) For waste-burning kilns not equipped with a wet scrubber, in place of hydrogen chloride..., maintain, and operate a continuous emission monitoring system for monitoring hydrogen chloride emissions...
Gomes, A P; Cruz, A G; Cadena, R S; Celeghini, R M S; Faria, J A F; Bolini, H M A; Pollonio, M A R; Granato, D
2011-06-01
We investigated the effect of sodium reduction by partial substitution of sodium chloride (NaCl) with potassium chloride (KCl) on the manufacture of Minas fresh cheese during 21 d of refrigerated storage. Four treatments of low-sodium Minas fresh cheese were manufactured, with partial replacement of NaCl by KCl at 0, 25, 50, and 75% (wt/wt), respectively. The cheeses showed differences in the content of moisture, ash, protein, salt, and lipid contents, as well as on the extent of proteolysis and hardness throughout the storage period. However, no difference was observed among treatments within each storage day tested. The partial substitution of NaCl by KCl decreased up to 51.8% the sodium concentration of the cheeses produced. The consumer test indicated that it is possible to manufacture a low-sodium Minas fresh cheese that is acceptable to consumers by partial substitution of NaCl by KCl at 25% (wt/wt) in the salting step. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Williams, Sophia N; Nussbaum, Eliezer; Chin, Terry W; Do, Paul C M; Singh, Kathryn E; Randhawa, Inderpal
2014-03-01
Newly implemented newborn screening (NBS) programs in California have resulted in a large subset of patients in whom at least two cystic fibrosis transmembrane conductance regulator (CFTR) mutations are identified, but subsequent sweat chloride analysis reveals normal or indeterminate values. These patients are diagnosed with CFTR-Related Metabolic Syndrome (CRMS). However, the natural progression and management of these patients are not clearly understood and frequently after the age of 1-year these patients are lost to follow-up with Cystic Fibrosis (CF) Centers. We present the first case of an infant who was referred to Miller Children's Hospital for a NBS positive for CF and subsequent discovery of identical mutations in six of his seven older brothers. Several siblings had positive sweat chloride results on repeat testing after the age of 3 years. We suggest the need for continued follow-up of CRMS in a CF center with diagnostic evaluation including repeat sweat chloride testing, beyond the currently recommended period. © 2013 Wiley Periodicals, Inc.
ARMY GAS-COOLED REACTOR SYSTEMS PROGRAM. Quarterly Progress Report, October 1-December 31, 1963
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1964-02-15
The ML-1 power plant did not operate during the report period; low power reactor physics and shielding experiments were conducted with the ML-1 reactor. Evaluation of moderate corrosion observed on aluminum parts exposed to the ML-1 shield solution indicated no loss of performance capability. Preliminary tests showed that the corrosion probably was caused by heavy metal ions or chlorides in the solution, Massive corrosion observed on the ML-1 fuel element lower spiders was attributed to sub-standard material; failure of some spiders was attributed to a combination of corrosion and sub-standard fabrication. Evaluation indicated that the upper spiders will perform satisfactorilymore » for the design lifetime. Modification, repair, and reassembly of the CSN-1A t-c set was completed. Operation demonstrated bearing stability, but showed that the turbine effective flow area was too large. A bypass flow path in the turbine was being corrected. The TCS-670 t-c set will be stored indefinitely. Since a commercial alternator will be used for the ML-1A, further development of the brushless alternator was postponed indefinitely. Evaluation revealed that the ML-1 improved precooler design was not compatible with ML-1A requirements. Operntion of the IB-17R-2 and -3 test elements in the GETR continued without incident. Preliminary design of the ML-1A power plant was initiated. Design of modifications to the GCRE facility to adapt it to testing the ML-1 reactor skid was initiated. (auth)« less
JTIDS electromagnetic compatibility in the 960-1215 MHz band
NASA Astrophysics Data System (ADS)
Lokuta, Robert S.
1992-01-01
The Joint Tactical Information Distribution System (JTIDS) operates in the 960-1215 MHz frequency band. This band is allocated world-wide on a primary basis for aeronautical radio navigation. JTIDS was designed to be electromagnetically compatible with the Air Traffic Control systems that operate in this band. Over the past 15 years, extensive bench tests, flight tests, and analyses were conducted to assess the electromagnetic compatibility (EMC) of JTIDS in the 960-1215 MHz band. This report summarizes the results and conclusions of these efforts, presents some supporting data and provides specific guidance for the operation of JTIDS within the National Air Space. Guidance and recommendations are also provided to assist in the definition and scope of a JTIDS EMC test and analysis effort.
Toxicity of chloride under winter low-flow conditions in an urban watershed in central Missouri, USA
Allert, Ann L.; Cole-Neal, Cavelle L.; Fairchild, James F.
2012-01-01
Deicers such as sodium chloride and calcium chloride are used to treat snow and ice on road surfaces and have been identified as potential stressors on aquatic life. Hinkson Creek is an urban stream on the Missouri 303(d) list of impaired waters and is classified as impaired due to urban non-point source pollution. A 7-day toxicity test using Ceriodaphnia dubia was conducted to assess the toxicity of stream water during snowmelt at seven sites within the Hinkson Creek watershed. Chloride concentrations at two sites (Site 6, 1252 mg Cl/L; Site 4, 301 mg Cl/L) exceeded the U.S. Environmental Protection Agency chronic criterion (230 mg Cl/L). Survival (30 %) and total reproduction (6.9 young/adult) of C. dubia at Site 6 was significantly lower than survival (100 %) and total reproduction (30.4 young/adult) at Site 1 (reference site). Results indicate that chloride concentrations are elevated above water-quality criteria and that chloride may be a significant chemical stressor for macroinvertebrate communities during winter low-flow conditions in the Hinkson Creek watershed.
Allert, Ann L; Cole-Neal, Cavelle L; Fairchild, James F
2012-08-01
Deicers such as sodium chloride and calcium chloride are used to treat snow and ice on road surfaces and have been identified as potential stressors on aquatic life. Hinkson Creek is an urban stream on the Missouri 303(d) list of impaired waters and is classified as impaired due to urban non-point source pollution. A 7-day toxicity test using Ceriodaphnia dubia was conducted to assess the toxicity of stream water during snowmelt at seven sites within the Hinkson Creek watershed. Chloride concentrations at two sites (Site 6, 1252 mg Cl/L; Site 4, 301 mg Cl/L) exceeded the U.S. Environmental Protection Agency chronic criterion (230 mg Cl/L). Survival (30 %) and total reproduction (6.9 young/adult) of C. dubia at Site 6 was significantly lower than survival (100 %) and total reproduction (30.4 young/adult) at Site 1 (reference site). Results indicate that chloride concentrations are elevated above water-quality criteria and that chloride may be a significant chemical stressor for macroinvertebrate communities during winter low-flow conditions in the Hinkson Creek watershed.
An optimal method for phosphorylation of rare earth chlorides in LiCl-KCl eutectic based waste salt
NASA Astrophysics Data System (ADS)
Eun, H. C.; Kim, J. H.; Cho, Y. Z.; Choi, J. H.; Lee, T. K.; Park, H. S.; Park, G. I.
2013-11-01
A study on an optimal method for the phosphorylation of rare earth chlorides in LiCl-KCl eutectic waste salt generated the pyrochemical process of spent nuclear fuel was performed. A reactor with a pitched four blade impeller was designed to create a homogeneous mixing zone in LiCl-KCl eutectic salt. A phosphorylation test of NdCl3 in the salt was carried out by changing the operation conditions (operation temperature, stirring rate, agent injection amount). Based on the results of the test, a proper operation condition (450 °C, 300 rpm, 1 eq. of phosphorylation agent) for over a 0.99 conversion ratio of NdCl3 to NdPO4 was determined. Under this condition, multi-component rare earth (La, Ce, Pr, Nd, Sm, Eu, Gd, Y) chlorides were effectively converted into phosphate forms. It was confirmed that the existing regeneration process of LiCl-KCl eutectic waste salt can be greatly improved and simplified through these phosphorylation test results.
Lee, Han-Seung; Ryu, Hwa-Sung; Park, Won-Jun; Ismail, Mohamed A.
2015-01-01
In this study, the ability of lithium nitrite and amino alcohol inhibitors to provide corrosion protection to reinforcing steel was investigated. Two types of specimens—reinforcing steel and a reinforced concrete prism that were exposed to chloride ion levels resembling the chloride attack environment—were prepared. An autoclave accelerated corrosion test was then conducted. The variables tested included the chloride-ion concentration and molar ratios of anti-corrosion ingredients in a CaOH2-saturated aqueous solution that simulated a cement-pore solution. A concentration of 25% was used for the lithium nitrite inhibitor LiNO2, and an 80% solution of dimethyl ethanolamine ((CH3)2NCH2CH2OH, hereinafter DMEA) was used for the amino alcohol inhibitor. The test results indicated that the lithium nitrite inhibitor displayed anti-corrosion properties at a molar ratio of inhibitor of ≥0.6; the amino alcohol inhibitor also displayed anti-corrosion properties at molar ratios of inhibitor greater than approximately 0.3. PMID:28787936
Laboratory performance of sweat conductivity for the screening of cystic fibrosis.
Greaves, Ronda F; Jolly, Lisa; Massie, John; Scott, Sue; Wiley, Veronica C; Metz, Michael P; Mackay, Richard J
2018-03-28
There are several complementary English-language guidelines for the performance of the sweat chloride test. These guidelines also incorporate information for the collection of conductivity samples. However, recommendations for the measurement and reporting of sweat conductivity are less clear than for sweat chloride. The aim of the study was to develop an understanding of the testing and reporting practices of sweat conductivity in Australasian laboratories. A survey specifically directed at conductivity testing was sent to the 12 laboratories registered with the Royal College of Pathologists of Australasia Quality Assurance Programs. Nine (75%) laboratories participated in the survey, seven of whom used Wescor Macroduct® for collecting sweat and the Wescor SWEAT·CHEK™ for conductivity testing, and the remaining two used the Wescor Nanoduct®. There was considerable variation in frequency and staffing for this test. Likewise, criteria about which patients it was inappropriate to test, definitions of adequate collection sweat rate, cutoffs and actions recommended on the basis of the result showed variations between laboratories. Variations in sweat conductivity testing and reporting reflect many of the same issues that were revealed in sweat chloride test audits and have the potential to lead to uncertainty about the result and the proper action in response to the result. We recommend that sweat testing guidelines should include clearer statements about the use of sweat conductivity.
Petti, S; Messano, G A
2016-05-01
Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (P<0.01). Log MRSA density reduction attributable to PCD was 1.16logcfu/cm(2), corresponding to 93% reduction of the baseline MRSA contamination. The disinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (<1cfu/cm(2)), but required 3h of exposure to photocatalysis. Thus, PCD could be considered for non-clinical surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Patch test reactions to metal salts in patients with different types of dermatitis.
Turčić, Petra; Marinović Kulišić, Sandra; Lipozenčić, Jasna
2013-01-01
Metal allergies can be a clinical problem, especially in atopic individuals. This study is unique and contributes with new knowledge in everyday life skin care of irritant and atopic dermatitis patients. The aim of the study was to determine the frequency of positive patch test reactions to metal contact allergens (potassium dichromate, cobalt chloride, nickel sulfate, white mercury precipitate) in patients diagnosed with allergic contact dermatitis, irritant contact dermatitis, and atopic dermatitis. Between 2007 and 2011, patch testing was performed in 2185 patients according to the International Contact Dermatitis Research Group technique. Study results showed statistically significant differences in patch test responses to 2 allergens, nickel sulfate (χ(2)=24.22; p<0.001) and cobalt chloride (χ(2)=22.72; p<0.001). Nickel sulfate was the most common allergen in allergic contact dermatitis and atopic dermatitis, while for irritant contact dermatitis the most common allergen was cobalt chloride. Among the 4 tested metal allergens, the most common and relevant was nickel sulfate (χ(2)=17.25; p<0.004), found in almost all study subjects. In conclusion, the increased awareness of allergens and their potential sources may help limit the use of these chemicals in consumer product manufacturing.
Zinc-chloride battery technology - Status 1983
NASA Astrophysics Data System (ADS)
Rowan, J. W.; Carr, P.; Warde, C. J.; Henriksen, G. L.
Zinc-chloride batteries are presently under development at Energy Development Associates (EDA) for load-leveling, electric-vehicle, and specialty applications. A 500-kWh battery system has been built at Detroit Edison's Charlotte substation near downtown Detroit. Following shakedown testing, this system will be installed at the Battery Energy Storage Test (BEST) Facility in Hillsborough, New Jersey, in July 1983. Data is presented also for a prototype 50-kWh battery which has successfully operated through 150 cycles. EDA has built and tested three 4-passenger automobiles. The maximum range achieved on a single charge was 200 miles at 40 mph. Recently, the electric-vehicle battery program at EDA has focused on commercial vehicles. Two vans, each powered with a 45-kWh zinc-chloride battery, have been built and track tested. These vehicles, which carry a payload of 1,000 pounds, have a top speed of 55 mph and an operational range in excess of 80 miles. In the specialty battery area, two 6-kWh 12-V reserve batteries have been built and tested. This type of battery offers the prospect of long shelf life and an energy density in excess of 100 Wh/lb.
Shear bond strength between resin cement and colored zirconia made with metal chlorides.
Kim, Ga-Hyun; Park, Sang-Won; Lee, Kwangmin; Oh, Gye-Jeong; Lim, Hyun-Pil
2015-06-01
Although the application of zirconia in esthetic prostheses has increased, the shear bond strength (SBS) between colored zirconia and resin cement has not been investigated. The purpose of this study was to compare the SBS between resin cement and colored zirconia made with metal chlorides. Sixty-four zirconia specimens were divided into 2 groups: one in which the specimens were bonded with resin cement, including 4-META (4-methacryloxyethyl trimellitic anhydride), and one in which the specimens were bonded with resin cement (SEcure, Sun Medical) after being processed with zirconia primer (Zirconia Liner), including 4-META. Each group was then divided into 4 subgroups depending on the coloring liquid. The subgroups were noncolored (control), commercial coloring liquid VITA In-Ceram 2000 YZ LL1, aqueous chromium chloride solution 0.1 wt%, and aqueous molybdenum chloride solution 0.1 wt%. Composite resin cylinders (Filtek Z250, 3M ESPE) were fabricated and bonded to the surface of the zirconia specimen with resin cement (SEcure). All specimens were stored in 37°C distilled water for 24 hours, and the SBS was measured with a universal testing machine. All data were analyzed statistically with 2-way ANOVA and tested post hoc with the Tukey test (α=.05). Significant differences were observed among the SBS values of the colored zirconia depending on the coloring liquid (P<.001) and whether they were processed with zirconia primer (P<.001). The SBS between colored zirconia and resin cement was significantly higher than that of noncolored zirconia and resin cement in groups processed with zirconia primer (P<.05). Colored zirconia immersed in aqueous molybdenum chloride solution showed a significantly higher SBS. Coloring liquid enhanced the SBS between resin cement and zirconia processed with zirconia primer. In particular, colored zirconia immersed in aqueous molybdenum chloride solution showed the highest SBS. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Effect of 10% Strontium Chloride and 5% Potassium Nitrate with Fluoride on Bleached Bovine Enamel
Alencar, Cristiane de Melo; Pedrinha, Victor Feliz; Araújo, Jesuína Lamartine Nogueira; Esteves, Renata Antunes; Silva da Silveira, Ana Daniela; Silva, Cecy Martins
2017-01-01
Background: Dental whitening has been increasingly sought out to improve dental aesthetics, but may cause chemical and morphological changes in dental enamel surfaces. Objective: This study evaluated in vitro the effect of 10% strontium chloride and 5% potassium nitrate with fluoride on bovine enamel, through tristimulus colorimetry, Knoop microhardness (KHN), and roughness after bleaching with 35% hydrogen peroxide (HP). Methods: The specimens were divided into three groups (n=15): GControl received bleaching treatment with 35% HP; GNitrate received bleaching with 35% HP followed by the application of 5% potassium nitrate with 2% sodium fluoride; and GStrontium received bleaching with 35% HP followed by the application of 10% strontium chloride on the enamel. Next, five specimens of each experimental group were subjected to KHN and tristimulus colorimetry tests, and 10 specimens were subjected to surface roughness (SR) tests. The values obtained for the different groups were compared through analysis of variance (ANOVA) followed by a post-hoc Tukey-Kramer test in addition to Student’s T-test for paired data. Results: In the intergroup comparison, KHN final differed statistically (p<0.05). The mean SR final of the experimental groups differed statistically from the GControl group (p<0.05). In addition, the groups did not differ in color variation (p>0.05). Conclusion: 10% strontium chloride and 5% potassium nitrate combined with 2% fluoride downplayed morphological changes to the enamel, without interfering with the effectiveness of the bleaching process. PMID:28979576
Comparative serological investigation between cat and tiger blood for transfusion
THENGCHAISRI, Naris; SINTHUSINGHA, Chayakrit; ARTHITWONG, Surapong; SATTASATHUCHANA, Panpicha
2017-01-01
Evidence suggests that non-domesticated felids inherited the same AB-erythrocyte antigens as domestic cats. To study the possible compatibility of tiger blood with that of other endangered felidae, blood samples from captive tigers and domestic cats were subjected to an in vitro study. The objectives of this study were to (1) identify whether the captive tigers had blood type AB and (2) determine the compatibility between the blood of captive tigers and that of domestic cats with a similar blood type. The anti-coagulated blood with ethylenediaminetetraacetic acid of 30 tigers was examined to determine blood type, and a crossmatching test was performed between tiger and cat blood. All 30 tigers had blood type A. Tube agglutination tests using tiger plasma with cat erythrocytes resulted in 100% agglutination (n=30) with type B cat erythrocytes and 76.7% agglutination (n=23) with type A cat erythrocytes. The 80% of major and 60% of minor compatibilities between blood from 10 tigers and 10 domestic cats with blood type A were found to pass compatibility tests. Interestingly, 3/10 of the tigers’ red blood cell samples were fully compatible with all cat plasmas, and 1/10 of the tiger plasma samples were fully compatible with the type A red cells of domestic cats. Although the result of present findings revealed type-A blood group in the surveyed tigers, the reaction of tiger plasma with Type-A red cell from cats suggested a possibility of other blood type in tigers. PMID:28450662
Comparative serological investigation between cat and tiger blood for transfusion.
Thengchaisri, Naris; Sinthusingha, Chayakrit; Arthitwong, Surapong; Sattasathuchana, Panpicha
2017-06-29
Evidence suggests that non-domesticated felids inherited the same AB-erythrocyte antigens as domestic cats. To study the possible compatibility of tiger blood with that of other endangered felidae, blood samples from captive tigers and domestic cats were subjected to an in vitro study. The objectives of this study were to (1) identify whether the captive tigers had blood type AB and (2) determine the compatibility between the blood of captive tigers and that of domestic cats with a similar blood type. The anti-coagulated blood with ethylenediaminetetraacetic acid of 30 tigers was examined to determine blood type, and a crossmatching test was performed between tiger and cat blood. All 30 tigers had blood type A. Tube agglutination tests using tiger plasma with cat erythrocytes resulted in 100% agglutination (n=30) with type B cat erythrocytes and 76.7% agglutination (n=23) with type A cat erythrocytes. The 80% of major and 60% of minor compatibilities between blood from 10 tigers and 10 domestic cats with blood type A were found to pass compatibility tests. Interestingly, 3/10 of the tigers' red blood cell samples were fully compatible with all cat plasmas, and 1/10 of the tiger plasma samples were fully compatible with the type A red cells of domestic cats. Although the result of present findings revealed type-A blood group in the surveyed tigers, the reaction of tiger plasma with Type-A red cell from cats suggested a possibility of other blood type in tigers.
NASA Technical Reports Server (NTRS)
Diwan, Ravinder M.
1989-01-01
The behavior of liquid oxygen (LOX) compatibility of aluminum lithium (Al-Li) alloys is investigated. Alloy systems of Alcoa 2090, vintages 1 to 3, and of Martin Marietta Corporation (MMC) Weldalite 049 were evaluated for their behavior related to the LOX compatibility employing liquid oxygen impact test conditions under ambient pressures and up to 1000 psi. The developments of these aluminum lithium alloys are of critical and significant interest because of their lower densities and higher specific strengths and improved mechanical properties at cryogenic temperatures. Of the different LOX impact tests carried out at the Marshall Space Flight Center (MSFC), it is seen that in certain test conditions at higher pressures, not all Al-Li alloys are LOX compatible. In case of any reactivity, it appears that lithium makes the material more sensitive at grain boundaries due to microstructural inhomogeneities and associated precipitate free zones (PFZ). The objectives were to identify and rationalize the microstructural mechanisms that could be relaxed to LOX compatibility behavior of the alloy system in consideration. The LOX compatibility behavior of Al-Li 2090 and Weldalite 049 is analyzed in detail using microstructural characterization techniques with light optical metallography, scanning electron microscopy (SEM), electron microprobe analysis, and surface studies using secondary ion mass spectrometry (SIMS), electron spectroscopy in chemical analysis (ESCA) and Auger electron spectroscopy (AES). Differences in the behavior of these aluminum lithium alloys are assessed and related to their chemistry, heat treatment conditions, and microstructural effects.
Environmentally compatible solid rocket propellants
NASA Technical Reports Server (NTRS)
Jacox, James L.; Bradford, Daniel J.
1995-01-01
Hercules' clean propellant development research is exploring three major types of clean propellant: (1) chloride-free formulations (no chlorine containing ingredients), being developed on the Clean Propellant Development and Demonstration (CPDD) contract sponsored by Phillips Laboratory, Edwards Air Force Base, CA; (2) low HCl scavenged formulations (HCl-scavenger added to propellant oxidized with ammonium perchlorate (AP)); and (3) low HCl formulations oxidized with a combination of AN and AP (with or without an HCl scavenger) to provide a significant reduction (relative to current solid rocket boosters) in exhaust HCl. These propellants provide performance approaching that of current systems, with less than 2 percent HCl in the exhaust, a significant reduction (greater than or equal to 70 percent) in exhaust HCl levels. Excellent processing, safety, and mechanical properties were achieved using only readily available, low cost ingredients. Two formulations, a sodium nitrate (NaNO3) scavenged HTPB and a chloride-free hydroxy terminated polyether (HTPE) propellant, were characterized for ballistic, mechanical, and rheological properties. In addition, the hazards properties were demonstrated to provide two families of class 1.3, 'zero-card' propellants. Further characterization is planned which includes demonstration of ballistic tailorability in subscale (one to 70 pound) motors over the range of burn rates required for retrofit into current Hercules space booster designs (Titan 4 SRMU and Delta 2 GEM).
NASA Astrophysics Data System (ADS)
Qiao, Xiaoping; Li, Helin; Zhao, Wenzhen; Li, Dejun
The absorption properties of zinc-nickel alloy electrolyte were studied by visible spectrophotometer. The results show that the relationship between the absorbance of the zinc-nickel alloy electrolyte and Ni2+ concentration in the electrolyte obeys Beer's law at 660 nm. In addition, other components except Ni2+ in the zinc-nickel alloy electrolyte such as zinc chloride, ammonium chloride, potassium chloride and boric acid have no obvious effect on the absorbance of zinc-nickel alloy electrolyte. Based on these properties, a new method is developed to determine Ni2+ concentration in zinc-nickel alloy electrolyte. Comparing with other methods, this method is simple, direct and accurate. Moreover, the whole testing process does not consume any reagent and dilution, and after testing, the electrolyte samples can be reused without any pollution to the environment.
NASA Technical Reports Server (NTRS)
Younger, G.
1978-01-01
A series of abuse tests on large lithium thionyl chloride cells was initiated. Performance data obtained in testing rectangular 2,000 and 10,000 ampere-hour cells are discussed and graphically presented.
Catalytic Hydroxylation of Polyethylenes
2017-01-01
Polyolefins account for 60% of global plastic consumption, but many potential applications of polyolefins require that their properties, such as compatibility with polar polymers, adhesion, gas permeability, and surface wetting, be improved. A strategy to overcome these deficiencies would involve the introduction of polar functionalities onto the polymer chain. Here, we describe the Ni-catalyzed hydroxylation of polyethylenes (LDPE, HDPE, and LLDPE) in the presence of mCPBA as an oxidant. Studies with cycloalkanes and pure, long-chain alkanes were conducted to assess precisely the selectivity of the reaction and the degree to which potential C–C bond cleavage of a radical intermediate occurs. Among the nickel catalysts we tested, [Ni(Me4Phen)3](BPh4)2 (Me4Phen = 3,4,7,8,-tetramethyl-1,10-phenanthroline) reacted with the highest turnover number (TON) for hydroxylation of cyclohexane and the highest selectivity for the formation of cyclohexanol over cyclohexanone (TON, 5560; cyclohexanol/(cyclohexanone + ε-caprolactone) ratio, 10.5). The oxidation of n-octadecane occurred at the secondary C–H bonds with 15.5:1 selectivity for formation of an alcohol over a ketone and 660 TON. Consistent with these data, the hydroxylation of various polyethylene materials by the combination of [Ni(Me4Phen)3](BPh4)2 and mCPBA led to the introduction of 2.0 to 5.5 functional groups (alcohol, ketone, alkyl chloride) per 100 monomer units with up to 88% selectivity for formation of alcohols over ketones or chloride. In contrast to more classical radical functionalizations of polyethylene, this catalytic process occurred without significant modification of the molecular weight of the polymer that would result from chain cleavage or cross-linking. Thus, the resulting materials are new compositions in which hydroxyl groups are located along the main chain of commercial, high molecular weight LDPE, HDPE, and LLDPE materials. These hydroxylated polyethylenes have improved wetting properties and serve as macroinitiators to synthesize graft polycaprolactones that compatibilize polyethylene–polycaprolactone blends. PMID:28852704
Ratner, Buddy D.
2007-01-01
The biomaterials community has been unable to accurately assign the term “blood compatible” to a biomaterial in spite of 50 years of intensive research on the subject. There is no clear consensus as to which materials are “blood compatible.” There are no standardized methods to assess blood compatibility. Since we use millions of devices in contact with blood each year, it is imperative we give serious thought to this intellectual catastrophe. In this perspective, I consider five hypotheses as to why progress has been slow in evolving a clear understanding of blood compatibility: Hypothesis 1 -- It is impossible to make a blood compatible material. Hypothesis 2 -- We do not understand the biology behind blood compatibility. Hypothesis 3 -- We do not understand how to test for or evaluate blood compatibility. Hypothesis 4 -- Certain materials of natural origin seem to show better blood compatibility but we do not know how to exploit this concept. Hypothesis 5 -- We now have better blood compatible materials but the regulatory and economic climate prevent adoption in clinical practice. PMID:17689608
NASA Technical Reports Server (NTRS)
1980-01-01
The compatibility of the Multimission Modular Spacecraft (MMS) Ground Support Software System (GSSS), currently operational on a ModComp IV/35, with the VAX 11/780 system is discussed. The compatibility is examined in various key areas of the GSSS through the results of in depth testing performed on the VAX 11/780 and ModComp IV/35 systems. The compatibility of the GSSS with the ModComp CLASSIC is presented based upon projections from ModComp supplied literature.
Thyssen, Jacob Pontoppidan; Ross-Hansen, Katrine; Menné, Torkil; Johansen, Jeanne Duus
2010-08-01
Contact allergy epidemics to chromate and nickel were addressed in Denmark in 1983 and 1990 by regulatory interventions. To evaluate whether regulatory interventions on nickel and chromate exposure have reduced the proportion of strong patch test reactions. 22 506 patients with dermatitis aged 4-99 years were patch tested with nickel sulfate, potassium dichromate, or cobalt chloride between 1977 and 2009. The proportion of 3+ reactions to nickel sulfate was reduced and almost disappeared after the mid- and late 1980s (P-trend = 0.001). Today, 1+ and 2+ nickel reactions occur equally frequent. Cobalt chloride patch test reactivity reflected the nickel development to some degree. The proportion of 3+ reactions to potassium dichromate was reduced during the 1980s (P-trend = 0.13), whereas the proportion of 2+ reactions to potassium dichromate have increased in recent years. The decrease in nickel sulfate and cobalt chloride 3+ patch test reactivity began long before the Danish nickel regulation came into effect. This could be because of research activity at the time as well as political attention in Northern Europe. The chromate content in cement regulation may have changed the epidemiology of patch test reactivity; however, in recent years, 2+ reactions to chromate have increased markedly, a development that should be carefully followed.
Al-Amin, Md Mamun; Reza, Hasan Mahmud; Saadi, Hasan Mahmud; Mahmud, Waich; Ibrahim, Abdirahman Adam; Alam, Musrura Mefta; Kabir, Nadia; Saifullah, A R M; Tropa, Sarjana Tarannum; Quddus, A H M Ruhul
2016-04-15
Aluminum chloride induces neurodegenerative disease in animal model. Evidence suggests that aluminum intake results in the activation of glial cells and generation of reactive oxygen species. By contrast, astaxanthin is an antioxidant having potential neuroprotective activity. In this study, we investigate the effect of astaxanthin on aluminum chloride-exposed behavioral brain function and neuronal oxidative stress (OS). Male Swiss albino mice (4 months old) were divided into 4 groups: (i) control (distilled water), (ii) aluminum chloride, (iii) astaxanthin+aluminum chloride, and (iv) astaxanthin. Two behavioral tests; radial arm maze and open field test were conducted, and OS markers were assayed from the brain and liver tissues following 42 days of treatment. Aluminum exposed group showed a significant reduction in spatial memory performance and anxiety-like behavior. Moreover, aluminum group exhibited a marked deterioration of oxidative markers; lipid peroxidation (MDA), nitric oxide (NO), glutathione (GSH) and advanced oxidation of protein products (AOPP) in the brain. To the contrary, co-administration of astaxanthin and aluminum has shown improved spatial memory, locomotor activity, and OS. These results indicate that astaxanthin improves aluminum-induced impaired memory performances presumably by the reduction of OS in the distinct brain regions. We suggest a future study to determine the underlying mechanism of astaxanthin in improving aluminum-exposed behavioral deficits. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Estill, C.F.; Kovein, R.J.; Jones, J.H.
1999-03-26
The National Institute for Occupational Safety and Health (NIOSH) is currently conducting research on ventilation controls to reduce furniture stripping exposures to methylene chloride to the OSHA PEL of 25 ppm. Low cost ventilation systems were designed by NIOSH researchers along with Benny Bixenman of Benco Sales, Inc. (Forney, TX). The controls were constructed and installed by Benco Sales. This report compares the methylene chloride levels of one worker stripping furniture using the recently installed ventilation controls and using the existing controls. During the survey, two different chemical stripping solutions (a standard formulation and a low methylene chloride content formulation)more » were used and compared. This survey tested three control combinations: (1) new ventilation, low methylene chloride stripper, (2) new ventilation, standard stripping solution, and (3) old ventilation, standard stripping solution. During each test, sorbent tube sampling and real-time sampling were employed. Sorbent tube, data collected in the worker's breathing zone, ranged from 300 to 387 ppm. Real-time data showed breathing zone exposures to range from 211 to 383 ppm while stripping and 164 to 230 ppm while rinsing. Data were inconclusive to determine which ventilation system or stripping solution produced the lowest exposures. Recommendations are made in the report to improve the newly installed ventilation controls.« less
40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2014 CFR
2014-07-01
... installed in each baghouse compartment or cell. For negative pressure or induced air fabric filters, the bag... hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner or operator must install, calibrate, maintain, and operate a CEMS for monitoring hydrogen chloride emissions discharged to...
40 CFR 60.2730 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2012 CFR
2012-07-01
... detection system must be installed in each baghouse compartment or cell. For negative pressure or induced... scrubber, in place of hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner... for monitoring hydrogen chloride emissions discharged to the atmosphere and record the output of the...
40 CFR 60.2165 - What monitoring equipment must I install and what parameters must I monitor?
Code of Federal Regulations, 2012 CFR
2012-07-01
... leak detection system must be installed in each baghouse compartment or cell. For negative pressure or... scrubber, in place of hydrogen chloride testing with EPA Method 321 at 40 CFR part 63, appendix A, an owner... for monitoring hydrogen chloride emissions discharged to the atmosphere and record the output of the...
... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... D. R., Editors (2006). Contemporary Practice in Clinical Chemistry, AACC Press, Washington, DC. Pp. 487-490. Bennett, ...
... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... D. R., Editors (© 2006). Contemporary Practice in Clinical Chemistry: AACC Press, Washington, DC. Pp 281-287. Wu, ...
... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... Missouri. Pp. 312-315. Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Burtis CA, Ashwood ER and ...
Selection and propagation of highly graft-compatible Douglas-fir rootstocksa case history.
Donald L. Copes
1981-01-01
Two populations of Douglas-fir trees were screened for graft compatibility. Two-stage testing procedures were used with either high- or low-intensity screening in the first step. Of 303 trees, 16 (5 percent) were found to be 90- to 100-percent graft compatible and suitable for seed orchard use as rootstocks. High-intensity screening in the first stage was more...
78 FR 1162 - Cardiovascular Devices; Reclassification of External Cardiac Compressor
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... safety and electromagnetic compatibility; For devices containing software, software verification... electromagnetic compatibility; For devices containing software, software verification, validation, and hazard... electrical components, appropriate analysis and testing must validate electrical safety and electromagnetic...
DOE Office of Scientific and Technical Information (OSTI.GOV)
MM Hall
2006-01-31
A major materials selection and qualification issue identified in the Space Materials Plan is the potential for creating materials compatibility problems by combining dissimilar reactor core, Brayton Unit and other power conversion plant materials in a recirculating, inert He/Xe gas loop containing reactive impurity gases. Reported here are results of equilibrium thermochemical analyses that address the compatibility of space nuclear power plant (SNPP) materials in high temperature impure He gas environments. These studies provide early information regarding the constraints that exist for SNPP materials selection and provide guidance for establishing test objectives and environments for SNPP materials qualification testing.
NASA Astrophysics Data System (ADS)
Kozakevych, Roman B.; Korobeinyk, Alina V.; Bolbukh, Yulia M.; Tertykh, Valentin A.; Mikhalovska, Lyuba I.; Zienkiewicz-Strzałka, Malgorzlata; Deryło-Marczewska, Anna
2018-03-01
The silica and copper oxide nanoparticles were embedded into the polyvinyl chloride film and obtained filled composites were tested as a catalyst in the reaction of the NO release from appropriate biomolecules. Obtained materials were characterized using scanning electron, atomic-force microscopies and thermomechanical analysis. It has been shown that the introduced particles are distributed uniformly in the polymeric matrix of hybrid composite and such film produces a significant amount of NO when reacts with S-nitrosothiols. At the same time, the unfilled polyvinyl chloride film had no statistically significant catalytic activity.
... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... mmol/L 1 from Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Burtis CA, Ashwood ER, Bruns ...
Corrosion Sensor for Monitoring the Service Condition of Chloride-Contaminated Cement Mortar
Lu, Shuang; Ba, Heng-Jing
2010-01-01
A corrosion sensor for monitoring the corrosion state of cover mortar was developed. The sensor was tested in cement mortar, with and without the addition of chloride to simulate the adverse effects of chloride-contaminated environmental conditions on concrete structures. In brief, a linear polarization resistance method combined with an embeddable reference electrode was utilized to measure the polarization resistance (Rp) using built-in sensor electrodes. Subsequently, electrochemical impedance spectroscopy in the frequency range of 1 kHz to 50 kHz was used to obtain the cement mortar resistance (Rs). The results show that the polarization resistance is related to the chloride content and Rs; ln (Rp) is linearly related to the Rs values in mortar without added chloride. The relationships observed between the Rp of the steel anodes and the resistance of the surrounding cement mortar measured by the corrosion sensor confirms that Rs can indicate the corrosion state of concrete structures. PMID:22319347
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, J.E.; Klaine, S.J.
The field cricket, Acheta domesticus, was used as a test organism to determine the effects of heavy metal exposure on cellular immunity. Insects were separated by sex and exposed to cadmium chloride or mercuric chloride at concentrations of 0, 2.5, and 5.0 ug/g. Exposures consisted of injecting the chemicals into the hemocoel of each insect on days 0, 2, and 4. Hemolymph was collected on day 7 of the study to determine total hemocyte counts, protein levels, and phenoloxidase activity in individual insects. Cadmium chloride decreased the total number of hemocytes in male crickets at 2.5 and 5.0 ug/g andmore » in female crickets at 5.0 ug/g. Protein levels increased in a dose dependent manner in the males but only slightly increased in the females. Mercuric chloride caused a dose-dependent increase in total hemocytes in both male and female crickets. In addition, mercuric chloride caused a dose-dependent increase in protein levels in males but not females.« less
Advanced intermediate temperature sodium-nickel chloride batteries with ultra-high energy density.
Li, Guosheng; Lu, Xiaochuan; Kim, Jin Y; Meinhardt, Kerry D; Chang, Hee Jung; Canfield, Nathan L; Sprenkle, Vincent L
2016-02-11
Sodium-metal halide batteries have been considered as one of the more attractive technologies for stationary electrical energy storage, however, they are not used for broader applications despite their relatively well-known redox system. One of the roadblocks hindering market penetration is the high-operating temperature. Here we demonstrate that planar sodium-nickel chloride batteries can be operated at an intermediate temperature of 190 °C with ultra-high energy density. A specific energy density of 350 Wh kg(-1), higher than that of conventional tubular sodium-nickel chloride batteries (280 °C), is obtained for planar sodium-nickel chloride batteries operated at 190 °C over a long-term cell test (1,000 cycles), and it attributed to the slower particle growth of the cathode materials at the lower operating temperature. Results reported here demonstrate that planar sodium-nickel chloride batteries operated at an intermediate temperature could greatly benefit this traditional energy storage technology by improving battery energy density, cycle life and reducing material costs.
Advanced intermediate temperature sodium-nickel chloride batteries with ultra-high energy density
NASA Astrophysics Data System (ADS)
Li, Guosheng; Lu, Xiaochuan; Kim, Jin Y.; Meinhardt, Kerry D.; Chang, Hee Jung; Canfield, Nathan L.; Sprenkle, Vincent L.
2016-02-01
Sodium-metal halide batteries have been considered as one of the more attractive technologies for stationary electrical energy storage, however, they are not used for broader applications despite their relatively well-known redox system. One of the roadblocks hindering market penetration is the high-operating temperature. Here we demonstrate that planar sodium-nickel chloride batteries can be operated at an intermediate temperature of 190 °C with ultra-high energy density. A specific energy density of 350 Wh kg-1, higher than that of conventional tubular sodium-nickel chloride batteries (280 °C), is obtained for planar sodium-nickel chloride batteries operated at 190 °C over a long-term cell test (1,000 cycles), and it attributed to the slower particle growth of the cathode materials at the lower operating temperature. Results reported here demonstrate that planar sodium-nickel chloride batteries operated at an intermediate temperature could greatly benefit this traditional energy storage technology by improving battery energy density, cycle life and reducing material costs.
Mechanism of sodium and chloride transport in the thin ascending limb of Henle.
Imai, M; Kokko, J P
1976-01-01
Our previous in vitro studies have disclosed that the thin ascending limb of Henle (tALH) possesses some unique membrane characteristics. In those studies we failed to demonstrated active transport of sodium chloride by the tALH, although it was shown that the isotopic permeability to sodium and chloride was unusually high. However, we did not examine the mechanisms by which the apparent high permeation of sodium chloride occurs. Thus the purpose of the present studies was to elucidate the mechanism of sodium chloride transport across the isolated tALH of the rabbit by conducting four different types of studies: (1) comparison of the observed chloride and sodium flux ratios to those predicted by Ussing's equation under imposed salt concentration gradients; (2) kinetic evaluation of chloride and sodium fluxes; (3) examination of the effect of bromide on the kinetics of chloride transport; and (4) experiments to test for the existence of exchange diffusion of chloride. In the first set of studies the predicted and the theoretical flux ratios of sodium were identical in those experiments in which sodium chloride was added either to the perfusate or to the bath. However, the observed chloride flux ratio, lumen-to-bath/bath-to-lumen, was significantly lower than that predicted from Ussing's equation when 100 mM sodium chloride was added to the bath. In the second set of experiments the apparent isotopic permeability for sodium and for chloride was measured under varying perfusate and bath NaCl concentrations. There was no statistical change in the apparent sodium permeability coefficient when the NaCl concentration was raised by varying increments from 85.5 to 309.5 mM. However, permeation of 36Cl decrease significantly with an increase in Cl from 73.6 to 598.6 mM. These events could be explained by a two component chloride transport process consisting of simple diffusion and a saturable facilitated diffusion process with a Vmax = 3.71 neq mm-1 min-1. In the third set of studies it was shown that bromide inhibits transport of chloride and that the magnitude of inhibition is dependent on chloride concentrations. The fourth set of studies ruled out the existence of exchange diffusion. In conclusion, these studies indicate that sodium transport across tALH is by simple passive diffusion, while chloride transport across tALH involves at least two mechanisms: (1) simple passive diffusion; and (2) a specific membrane interaction process (carrier-mediated) which is competitively inhibited by bromide. PMID:993330
Doorn, J; Storteboom, T T R; Mulder, A M; de Jong, W H A; Rottier, B L; Kema, I P
2015-07-01
Measurement of chloride in sweat is an essential part of the diagnostic algorithm for cystic fibrosis. The lack in sensitivity and reproducibility of current methods led us to develop an ion chromatography/high-performance liquid chromatography (IC/HPLC) method, suitable for the analysis of both chloride and sodium in small volumes of sweat. Precision, linearity and limit of detection of an in-house developed IC/HPLC method were established. Method comparison between the newly developed IC/HPLC method and the traditional Chlorocounter was performed, and trueness was determined using Passing Bablok method comparison with external quality assurance material (Royal College of Pathologists of Australasia). Precision and linearity fulfill criteria as established by UK guidelines are comparable with inductively coupled plasma-mass spectrometry methods. Passing Bablok analysis demonstrated excellent correlation between IC/HPLC measurements and external quality assessment target values, for both chloride and sodium. With a limit of quantitation of 0.95 mmol/L, our method is suitable for the analysis of small amounts of sweat and can thus be used in combination with the Macroduct collection system. Although a chromatographic application results in a somewhat more expensive test compared to a Chlorocounter test, more accurate measurements are achieved. In addition, simultaneous measurements of sodium concentrations will result in better detection of false positives, less test repeating and thus faster and more accurate and effective diagnosis. The described IC/HPLC method, therefore, provides a precise, relatively cheap and easy-to-handle application for the analysis of both chloride and sodium in sweat. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Environmentally Friendly Corrosion Preventative Compounds
NASA Technical Reports Server (NTRS)
Calle, Luz Marina; Montgomery, Eliza; Kolody, Mark; Curran, Jerry; Back, Teddy; Balles, Angela
2012-01-01
The objective of the Ground Systems Development and Operations Program Environmentally Friendly Corrosion Protective Coatings and Corrosion Preventive Compounds (CPCs) project is to identify, test, and develop qualification criteria for the use of environmentally friendly corrosion protective coatings and CPCs for flight hardware and ground support equipment. This document is the Final Report for Phase I evaluations, which included physical property, corrosion resistance, and NASA spaceport environment compatibility testing and analysis of fifteen CPC types. The CPCs consisted of ten different oily film CPCs and five different wax or grease CPC types. Physical property testing encompassed measuring various properties of the bulk CPCs, while corrosion resistance testing directly measured the ability of each CPC material to protect various metals against corrosion. The NASA spaceport environment compatibility testing included common tests required by NASA-STD-6001, "Flammability, Odor, Offgassing, and Compatibility Requirements and Test Procedures for Materials in Environments that Support Combustion". At the end of Phase I, CPC materials were down-selected for inclusion in the next test phases. This final report includes all data and analysis of results obtained by following the experimental test plan that was developed as part of the project. Highlights of the results are summarized by test criteria type.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasschau, M.R.; Skaggs, M.M.; Chen, E.C.M.
Stress has been reported to accelerate protein catabolism in man and animals and as a result one can expect to observe changes in certain amino acids pools of these organisms. In the present study, the Gulf Coast sea anemone, Bunodosoma cavernata, was used as the test animal and free amino acid levels of whole animals were measured following stressed conditions. Sea anemones were chosen as the test animals since they are sessile and, due to the nature of their morphology, they have few mechanisms by which they can escape environmental stress. The animals were exposed to sublethal concentrations of mercuricmore » chloride and cadmium chloride and the organic amines, aniline, diethanol amine (DEA), and ethylene diamine (EDA). Chloride salts of mercury and cadmium were chosen rather than other anions since chloride is the most abundant anion in seawater. These two particular metals were chosen as challenge compounds due to their high toxicity in aquatic systems. The three organic amines were chosen for their relatively high water solubility and low vapor pressure in an aqueous solution, thus insuring that the toxic compound is retained in the test solution. Since organic amines are used extensively in the Gulf Coast industrial complex, there is a high probability of these compounds contaminating the marine environment. Results indicate that the reaction of B. cavernata to stress from organic amines is similar to the response to heavy metals, only more extensive.« less
Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup
NASA Technical Reports Server (NTRS)
Harris, Patrick K.; Block, Nathan F.
2002-01-01
The MIL-STD-462 CS02 conducted susceptibility test setup, performed during electromagnetic compatibility (EMC) testing, consists of an audio transformer with the secondary used as an inductor and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This can damage flight hardware and caused a catastrophic failure to an item tested in the Goddard Space Flight Center (GSFC) Large EMC Test Facility.
Hydrazine-Compatible Elastomer
NASA Technical Reports Server (NTRS)
Markles, O., F.; Dye, T. G.
1982-01-01
Hydrazine hardly reacts with ethylene propylene diene monomer, even at high temperatures. According to report to tests, EPDM is most hydrazine-compatible material among elastomers. Has strong potential as valve-seat and O-ring seal with hydrazine, especially at high temperatures.
NASA Technical Reports Server (NTRS)
Denson, J. R.; Toy, A.
1974-01-01
Compatibility data for aluminum alloy 2219-T87 and titanium alloy Ti-6Al-4V were obtained while these alloys were exposed to both liquid and vapor fluorine and FLOX at -320 F + or -10 F. These data were obtained using a new low cost compatibility method which incorporates totally sealed containers and double dogbone test specimens and propellants in the simultaneous exposure to vapor and liquid phases. The compatibility investigation covered a storage period in excess of one year. Pitting was more severe in the 2219-T87 aluminum alloy than in the Ti-6Al-4V titanium alloy for both fluorine and FLOX exposure. The degree of chemical attack is more severe in the presence of FLOX than in fluorine and phase. The mechanical properties of the two alloys were not affected by storage in either of the two propellants.
Environmentally compatible hand wipe cleaning solvents
NASA Technical Reports Server (NTRS)
Clayton, Catherine P.; Kovach, Michael P.
1995-01-01
Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.
Biochemistry of whole blood in poly(ethylene-co-ethylacrylate) experimental blood containers.
Horowitz, B; Rowe, A W; Stryker, M H; Van der Sande, J; Waldman, A A; Wong, S C; Gass, J D; Woods, K R
1985-01-01
The biochemical status of whole blood stored in containers fabricated of ethylene ethylacrylate (EEA) film was monitored at several times during 4 weeks of storage at 4 degrees C. Fifteen biochemical indicators were studied to reflect on erythrocyte integrity, cellular metabolism, plasma protein stability, and microaggregate formation. Comparison to storage in polyvinyl chloride (PVC) containers was made by distributing aliquots from each unit of blood among the containers being compared. Whole blood in EEA developed significantly higher levels of plasma hemoglobin, erythrocyte osmotic fragility, and D-glycerate-2,3-diphosphate (2,3-DPG), and somewhat greater glucose utilization, lactate production, and pH. These biochemical differences were not of great magnitude and the data suggest that EEA containers are compatible with the storage of whole blood.
A precision structured smart hydrogel for sensing applications
NASA Astrophysics Data System (ADS)
Menges, J.; Kleinschmidt, P.; Bart, H.-J.; Oesterschulze, E.
2017-10-01
We report on a macroinitiator based smart hydrogel film applied on a microcantilever for sensing applications. The studied hydrogel features a comparatively wide dynamic range for changes in the electrolyte's ionic strength. Furthermore, it offers a simple spin coating process for thin film deposition as well as the capability to obtain high aspect ratio microstructures by reactive ion etching. This makes the hydrogel compatible to microelectromechanical system integration. As a proof of concept, we study the response of hydrogel functionalized cantilevers in aqueous sodium chloride solutions of varying ionic strength. In contrast to the majority of hydrogel materials reported in the literature, we found that our hydrogel still responds in high ionic strength environments. This may be of future interest for sensing e.g., in sea water or physiological environments like urine.
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2001-01-01
In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.
A NEW METHOD OF SWEAT TESTING: THE CF QUANTUM® SWEAT TEST
Rock, Michael J.; Makholm, Linda; Eickhoff, Jens
2015-01-01
Background Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Methods Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. Results The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97–0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94–100%) and 96% (95% confidence interval: 89–99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%)(p < 0.001). In the post-test questionnaire, 88% of subjects/parents preferred the CFQT test. Conclusions The CFQT is a fast and simple method of quantitative sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. PMID:24862724
Hyperbaric Oxygen Therapy and Oxygen Compatibility of Skin and Wound Care Products
Bernatchez, Stéphanie F.; Tucker, Joseph; Chiffoleau, Gwenael
2017-01-01
Objective: Use test methods to assess the oxygen compatibility of various wound care products. Approach: There are currently no standard test methods specifically for evaluating the oxygen compatibility and safety of materials under hyperbaric oxygen (HBO) conditions. However, tests such as the oxygen index (OI), oxygen exposure (OE), and autogenous ignition temperature (AIT) can provide useful information. Results: The OI test measures the minimum oxygen concentration that will support candle-like burning, and it was used to test 44 materials. All but two exhibited an OI equal to or greater (safer) than a control material commonly used in HBO. The OE test exposes each material to an oxygen-enriched atmosphere (>99.5% oxygen) to monitor temperature and pressure for an extended duration. The results of the OE testing indicated that none of the 44 articles tested with this method self-ignited within the 60°C, 3 atm pressurized oxygen atmosphere. The AIT test exposes materials to a rapid ramp up in temperature in HBO conditions at 3 atm until ignition occurs. Ten wound care materials and seven materials usually avoided in HBO chambers were tested. The AIT ranged from 138°C to 384°C for wound care products and from 146°C to 420°C for the other materials. Innovation: This work provides useful data and recommendations to help develop a new standard approach for evaluating the HBO compatibility of wound care products to ensure safety for patients and clinicians. Conclusion: The development of an additional test to measure the risk of electrostatic discharge of materials in HBO conditions is needed. PMID:29098113
Permeability of Concrete with Recycled Concrete Aggregate and Pozzolanic Materials under Stress
Wang, Hailong; Sun, Xiaoyan; Wang, Junjie; Monteiro, Paulo J.M.
2016-01-01
The research reported herein studied the permeability of concrete containing recycled-concrete aggregate (RA), superfine phosphorous slag (PHS), and ground granulated blast-furnace slag (GGBS) with and without stress. Test results showed that the chloride diffusion coefficient of RA concrete (RAC) without external loads decreased with time, and the permeability of RAC is much lower than that of the reference concrete due to the on-going hydration and the pozzolanic reaction provided by the PHS and GGBS additives in the RAC mixture. The permeability of chloride under flexural load is much more sensitive than that under compressive load due to the differences in porosity and cracking pattern. At low compressive stress levels, the permeability of chloride decreased by the closing of pores and microcracks within RAC specimens. However, in a relatively short time the chloride diffusion coefficient and the chloride content increased rapidly with the increase of compressive stress when it exceeded a threshold stress level of approximate 35% of the ultimate compressive strength. Under flexural stress, the chloride transport capability increased with the increase of stress level and time. At high compressive and flexural stress levels, creep had a significant effect on the permeability of chloride in the RAC specimens due to the damage from the nucleation and propagation of microcracks over time. It is apparent that mortar cracking has more of a significant effect on the chloride transport in concrete than cracking in the interfacial transition zone (ITZ). PMID:28773376
Potato plants (Solanum tuberosum L.) are chloride-sensitive: Is this dogma valid?
Hütsch, Birgit W; Keipp, Katrin; Glaser, Ann-Kathrin; Schubert, Sven
2018-06-01
Chloride sensitivity of the potato (Solanum tuberosum L.) cultivars Marabel and Désirée was investigated in two pot experiments (soil/sand mixture and hydroponics). It was tested whether there are differential effects of KCl and K 2 SO 4 application on tuber yield and tuber quality, and whether both potato cultivars differ in their chloride sensitivity. Tuber yield, dry matter percentage of the tubers, starch concentration and starch yield were not significantly affected by potassium source (K 2 SO 4 or KCl). After exposure to salt stress in hydroponics (100 mmol L -1 NaCl, 50 mmol L -1 Na 2 SO 4 , 50 mmol L -1 CaCl 2 ) for 5 days, 3-week-old potato plants had significantly reduced shoot dry mass after NaCl and Na 2 SO 4 application. However, CaCl 2 treatment did not significantly affect shoot growth, although the chloride concentration reached 65 to 74 mg Cl - mg -1 dry matter, similar to the NaCl treatment. In contrast, growth reductions were closely related to sodium concentrations, thus plants suffered sodium toxicity and not chloride toxicity. Both potato cultivars are chloride-resistant and can be fertilised with KCl instead of K 2 SO 4 without the risk of depression in tuber yield or tuber quality. The statement that potatoes are chloride-sensitive and that chloride has negative effects on yield performance needs reconsideration. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Zammit, Carla M; Mangold, Stefanie; Jonna, Venkateswara rao; Mutch, Lesley A; Watling, Helen R; Dopson, Mark; Watkin, Elizabeth L J
2012-01-01
High concentrations of chloride ions inhibit the growth of acidophilic microorganisms used in biomining, a problem particularly relevant to Western Australian and Chilean biomining operations. Despite this, little is known about the mechanisms acidophiles adopt in order to tolerate high chloride ion concentrations. This study aimed to investigate the impact of increasing concentrations of chloride ions on the population dynamics of a mixed culture during pyrite bioleaching and apply proteomics to elucidate how two species from this mixed culture alter their proteomes under chloride stress. A mixture consisting of well-known biomining microorganisms and an enrichment culture obtained from an acidic saline drain were tested for their ability to bioleach pyrite in the presence of 0, 3.5, 7, and 20 g L(-1) NaCl. Microorganisms from the enrichment culture were found to out-compete the known biomining microorganisms, independent of the chloride ion concentration. The proteomes of the Gram-positive acidophile Acidimicrobium ferrooxidans and the Gram-negative acidophile Acidithiobacillus caldus grown in the presence or absence of chloride ions were investigated. Analysis of differential expression showed that acidophilic microorganisms adopted several changes in their proteomes in the presence of chloride ions, suggesting the following strategies to combat the NaCl stress: adaptation of the cell membrane, the accumulation of amino acids possibly as a form of osmoprotectant, and the expression of a YceI family protein involved in acid and osmotic-related stress.
Permeability of Concrete with Recycled Concrete Aggregate and Pozzolanic Materials under Stress.
Wang, Hailong; Sun, Xiaoyan; Wang, Junjie; Monteiro, Paulo J M
2016-03-30
The research reported herein studied the permeability of concrete containing recycled-concrete aggregate (RA), superfine phosphorous slag (PHS), and ground granulated blast-furnace slag (GGBS) with and without stress. Test results showed that the chloride diffusion coefficient of RA concrete (RAC) without external loads decreased with time, and the permeability of RAC is much lower than that of the reference concrete due to the on-going hydration and the pozzolanic reaction provided by the PHS and GGBS additives in the RAC mixture. The permeability of chloride under flexural load is much more sensitive than that under compressive load due to the differences in porosity and cracking pattern. At low compressive stress levels, the permeability of chloride decreased by the closing of pores and microcracks within RAC specimens. However, in a relatively short time the chloride diffusion coefficient and the chloride content increased rapidly with the increase of compressive stress when it exceeded a threshold stress level of approximate 35% of the ultimate compressive strength. Under flexural stress, the chloride transport capability increased with the increase of stress level and time. At high compressive and flexural stress levels, creep had a significant effect on the permeability of chloride in the RAC specimens due to the damage from the nucleation and propagation of microcracks over time. It is apparent that mortar cracking has more of a significant effect on the chloride transport in concrete than cracking in the interfacial transition zone (ITZ).
Eisenhut, Michael
2007-01-01
All forms of malnutrition have been associated with increased severity of pneumonia, an increased pneumonia associated mortality and an increased risk of pulmonary fluid overload. Malnutrition was found to be associated with increased sweat sodium and chloride concentrations. A reduction of systemic sodium and chloride transport reflected in sweat sodium and chloride levels has been linked to increased severity of pulmonary edema in children with septicemia. Malnutrition causes a reduction in alveolar epithelial sodium and chloride transport which predisposes to death from lung injury. SUPPORTING EVIDENCE FOR THE HYPOTHESIS: Malnutrition caused reduced pulmonary fluid clearance in the rat model. Amiloride insensitive pulmonary fluid clearance in malnourished rats was reduced. The reduction in fluid clearance was reversible by beta agonists which increases epithelial sodium and chloride transport. Reduction of alveolar ion and fluid transport capacity explains the predisposition to death from pulmonary edema associated with intravenous fluids and blood transfusions in inpatients with malnutrition. Reduced alveolar epithelial ion transport impairs absorption of intra-alveolar inflammatory exudate in pneumonia leading to a increased severity of respiratory compromise and increased mortality. MEANS TO TEST THE HYPOTHESIS: Nasal potential difference measurements could compare airway epithelial sodium and chloride transport in patients with and without malnutrition and malnutrition associated lung disease. Sweat sodium and chloride concentrations could be compared in patients with and without respiratory disease associated with malnutrition and correlated with the severity of respiratory compromise.
Kim, Jimin P; Xie, Zhiwei; Creer, Michael; Liu, Zhiwen; Yang, Jian
2017-01-01
Chloride is an essential electrolyte that maintains homeostasis within the body, where abnormal chloride levels in biological fluids may indicate various diseases such as Cystic Fibrosis. However, current analytical solutions for chloride detection fail to meet the clinical needs of both high performance and low material or labor costs, hindering translation into clinical settings. Here we present a new class of fluorescence chloride sensors derived from a facile citrate -based synthesis platform that utilize dynamic quenching mechanisms. Based on this low-cost platform, we demonstrate for the first time a selective sensing strategy that uses a single fluorophore to detect multiple halides simultaneously, promising both selectivity and automation to improve performance and reduce labor costs. We also demonstrate the clinical utility of citrate-based sensors as a new sweat chloride test method for the diagnosis of Cystic Fibrosis by performing analytical validation with sweat controls and clinical validation with sweat from individuals with or without Cystic Fibrosis. Lastly, molecular modeling studies reveal the structural mechanism behind chloride sensing, serving to expand this class of fluorescence sensors with improved chloride sensitivities. Thus citrate-based fluorescent materials may enable low-cost, automated multi-analysis systems for simpler, yet accurate, point-of-care diagnostics that can be readily translated into clinical settings. More broadly, a wide range of medical, industrial, and environmental applications can be achieved with such a facile synthesis platform, demonstrated in our citrate-based biodegradable polymers with intrinsic fluorescence sensing.
2012-02-21
Testing and Materials °C Celsius DiEGME Diethylene Glycol Monomethyl Ether EPDM Ethylene Propylene Diene Monomer FARE Forward Area Refueling...urethane class AU, polyether urethane class EU, EPDM , Viton®, fluorosilicone class FQ, polytetrafluoroethylene (PTFE), polyolefin and polyester...sleeve Material not provided AAFARS 4720-00-540-1368 Hose, nonmetallic Material not provided AAFARS 4720-01-218-6958 Hose, preformed Rubber
Assessing a Couple's Relationship and Compatibility Using the MARI[R] Card Test and Mandala Drawings
ERIC Educational Resources Information Center
Frame, Phyllis G.
2006-01-01
This paper illustrates the use of the MARI[R] Card Test, a transpersonal assessment tool which includes archetypal designs and color choices, as well as the drawing of a white and black mandala, or circle picture, for assessing the compatibility of two people in a committed relationship. In an informal pilot research study, 22 couples were given…
New eutectic ionic liquids for lipase activation and enzymatic preparation of biodiesel†
Zhao, Hua; Baker, Gary A.; Holmes, Shaletha
2012-01-01
The enzymatic preparation of biodiesel has been hampered by the lack of suitable solvents with desirable properties such as high lipase compatibility, low cost, low viscosity, high biodegradability, and ease of product separation. Recent interest in using ionic liquids (ILs) as advanced reaction media has led to fast reaction rates and high yields in the enzymatic synthesis of biodiesel. However, conventional (i.e., cation–anion paired) ILs based on imidazolium and other quaternary ammonium salts remain too expensive for wide application at industrial scales. In this study, we report on newly-synthesized eutectic ILs derived from choline acetate or choline chloride coupled with biocompatible hydrogen-bond donors, such as glycerol. These eutectic solvents have favorable properties including low viscosity, high biodegradability, and excellent compatibility with Novozym® 435, a commercial immobilized Candida antarctica lipase B. Furthermore, in a model biodiesel synthesis system, we demonstrate high reaction rates for the enzymatic transesterification of Miglyol® oil 812 with methanol, catalyzed by Novozym® 435 in choline acetate/glycerol (1 : 1.5 molar ratio). The high conversion (97%) of the triglyceride obtained within 3 h, under optimal conditions, suggests that these novel eutectic solvents warrant further exploration as potential media in the enzymatic production of biodiesel. PMID:21283901
Rohlenová, J; Gryndler, M; Forczek, S T; Fuksová, K; Handova, V; Matucha, M
2009-05-15
Chloride, which comes into the forest ecosystem largely from the sea as aerosol (and has been in the past assumed to be inert), causes chlorination of soil organic matter. Studies of the chlorination showed that the content of organically bound chlorine in temperate forest soils is higher than that of chloride, and various chlorinated compounds are produced. Our study of chlorination of organic matter in the fermentation horizon of forest soil using radioisotope 36Cl and tracer techniques shows that microbial chlorination clearly prevails over abiotic, chlorination of soil organic matter being enzymatically mediated and proportional to chloride content and time. Long-term (>100 days) chlorination leads to more stable chlorinated substances contained in the organic layer of forest soil (overtime; chlorine is bound progressively more firmly in humic acids) and volatile organochlorines are formed. Penetration of chloride into microorganisms can be documented by the freezing/thawing technique. Chloride absorption in microorganisms in soil and in litter residues in the fermentation horizon complicates the analysis of 36Cl-chlorinated soil. The results show that the analytical procedure used should be tested for every soil type under study.
EMC (Electromagnetic Compatibility) System Test and Analysis Interface.
1983-05-01
D- R136 64 EMC (ELECTROARGNETIC COMPATIBILITY) SYSTEM TEST AND V ANALYSIS INTE FACE(J) BOEING CO SEATTLE WA E F BALL ET AL MAY 93 RRDC-TR-83-121...RADC-TR-83- 121 Final Tedical Report May 1963 EMC SYSTEM TEST AND ANAL YSIS INTERFACE_ The Boeing Company E. F. Ball, L. Knutson and B. L...Carlson *. . APPROVE FOR PUBLIC REESEk DIS TRIBUTION ULMTED D IS -ELECTE ,... DEC 20 1983 >- D" c: ROME AIR DEVELOPMENT CENTER * Air Force Systems Command
NASA Technical Reports Server (NTRS)
Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.
2015-01-01
This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.
Roy, James W; McInnis, Rodney; Bickerton, Greg; Gillis, Patricia L
2015-11-01
Groundwater contaminants, such as chloride from road salt, pose a threat to aquatic ecosystems when and where they discharge to surface waters. Here we study the application of a laboratory toxicity bioassay to field-collected samples from contaminated groundwater discharging to an urban stream. The objectives were to assess the potential toxicity of the discharging groundwater, while also exploring the suitability of such standard tests to site groundwater. Juvenile freshwater mussels were chosen as a groundwater-appropriate (endobenthic) test organism. Groundwater was sampled from 6 sites at approximate depths of 0, 10, and 50 cm below the sediment. Concentrations of chloride and several metals were above aquatic life guidelines in some samples. Exposure (96-h) to site groundwater resulted in survival of 90-100% and 80-100% for the 0-cm and deeper samples, respectively, indicating that groundwater may pose a toxicological threat to freshwater mussels. Several samples with high chloride had a survival rate of 80%, but generally there was poor correlation between survival and individual contaminants. Parallel juvenile mussel exposures using reconstituted water and NaCl predicted survival in the natural groundwater below 50% based on chloride concentrations. This indicates some protective ability of groundwater, possibly associated with water hardness. Finally, some technical issues with performing bioassays with groundwater were noted. First, aeration of previously anoxic groundwater samples caused marked changes in water quality (especially metal concentrations). Second, calcite crystals formed on the mussel shells in samples with elevated chloride and water hardness, though with no apparent negative effects. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Wood, Matthew R; Lalancette, Roger A
2013-04-01
The ortho-metallation product of the reaction of (±)-amphetamine with gold(III) chloride, [D,L-2-(2-aminopropyl)phenyl-κ(2)N,C(1)]dichloridogold(III), [Au(C9H12N)Cl2], and the two salts resulting from crystallization of (+)-methamphetamine with gold(III) chloride, D-methyl(1-phenylpropan-2-yl)azanium tetrachloridoaurate(III), (C10H16N)[AuCl4], and of (±)-ephedrine with gold(III) chloride, D,L-(1-hydroxy-1-phenylpropan-2-yl)(methyl)azanium tetrachloridoaurate(III), (C10H16NO)[AuCl4], have different structures. The first makes a bidentate complex directly with a dichloridogold(III) group, forming a six-membered ring structure; the second and third each form a salt with [AuCl4](-) (each has two formula units in the asymmetric unit). The organic components are all members of the same class of stimulants that are prevalent in illicit drug use. These structures are important contributions to the understanding of the microcrystal tests for these drugs that have been employed for well over 100 years.
Salivary analytes in patients with oral squamous cell carcinoma.
Fuchs, Petra Nola; Rogić, Dunja; Vidović-Juras, Danica; Susić, Mato; Milenović, Aleksandar; Brailo, Vlaho; Boras, Vanja Vucićević
2011-06-01
Literature data indicates that measurement of certain salivary constituents might serve as a useful diagnostic/prognostic tool in the patients with oral squamous cell carcinoma (OSCC). In 24 patients with OSCC (60 +/- 2.5 yrs) and in 24 controls (24 +/- 3.7 yrs) we have determined levels of salivary magnesium, calcium, copper, chloride, phosphate, potassium, sodium, total proteins and amylase. Sodium, potassium and chloride were determined by indirect potentiometry whereas copper, magnesium and phosphate were determined by atomic absorption spectrophotometry. Total proteins were determined by pyrogalol colorimetric method. Amylase levels were determined by continued colorimetric method. Statistical analysis was performed by use of chi2 test and Spearman's correlation test. The results of this study indicate that the concentrations of sodium and chloride were significantly elevated in patients with OSCC when compared to the controls. However, level of total protein was significantly decreased when compared to the healthy controls. Furthermore, there was a negative correlation between alcohol consumption and total protein concentration in patients with oral carcinoma. We might conclude that in patients with OSCC increased salivary sodium and chloride might reflect their overall dehydration status due to alcohol consumption rather than consequence of OSCC itself.
Deconstruction of lignocellulosic biomass with hydrated cerium (III) chloride in water and ethanol
Akalin, Mehmet K.; Das, Parthapratim; Alper, Koray; ...
2017-08-08
Lignocellulosic biomass was decomposed to produce crude bio-oil in water and ethanol using hydrated cerium (III) chloride as a catalyst. Use of the catalyst affected not only the yield of crude bio-oil but also the composition of bio-crude for both water and ethanol. The catalyst had a detrimental effect on the crude bio-oil yields obtained from water processing for all runs. However, in ethanol, use of the catalyst improved the crude bio-oil yields in all tested runs. The solid residue yields decreased with the catalyst use in the runs with water but increased in all studies with ethanol, except thosemore » with the shortest tested residence time of 10 min. The highest crude bio-oil yield of 48.2 wt% was obtained at 300 °C using 5 mmol of hydrated cerium (III) chloride at a residence time of 90 min in ethanol. The heating values of the crude bio-oils increased with the catalyst use for both water and ethanol processing. In conclusion, the highest heating value of 33.3 MJ kg –1 was obtained with hydrated cerium (III) chloride at 300 °C and a residence time of 120 min.« less
Deconstruction of lignocellulosic biomass with hydrated cerium (III) chloride in water and ethanol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akalin, Mehmet K.; Das, Parthapratim; Alper, Koray
Lignocellulosic biomass was decomposed to produce crude bio-oil in water and ethanol using hydrated cerium (III) chloride as a catalyst. Use of the catalyst affected not only the yield of crude bio-oil but also the composition of bio-crude for both water and ethanol. The catalyst had a detrimental effect on the crude bio-oil yields obtained from water processing for all runs. However, in ethanol, use of the catalyst improved the crude bio-oil yields in all tested runs. The solid residue yields decreased with the catalyst use in the runs with water but increased in all studies with ethanol, except thosemore » with the shortest tested residence time of 10 min. The highest crude bio-oil yield of 48.2 wt% was obtained at 300 °C using 5 mmol of hydrated cerium (III) chloride at a residence time of 90 min in ethanol. The heating values of the crude bio-oils increased with the catalyst use for both water and ethanol processing. In conclusion, the highest heating value of 33.3 MJ kg –1 was obtained with hydrated cerium (III) chloride at 300 °C and a residence time of 120 min.« less
Vaerewijck, M J M; Sabbe, K; Baré, J; Spengler, H-P; Favoreel, H W; Houf, K
2012-03-01
The efficacy of benzalkonium chloride and sodium hypochlorite against Acanthamoeba polyphaga and two Tetrahymena spp. was determined based on the European Standard EN 1276:2009 suspension test. Trophozoite viability was assessed by determination of the membrane integrity using flow cytometry as a fast screening technique. Bovine serum albumin was added to simulate clean (0.3 g/liter) and dirty (3 g/liter) conditions. Benzalkonium chloride caused cell lysis at concentrations above 50 mg/liter under clean and dirty conditions. A concentration of 50 mg of free chlorine per liter had a strong biocidal effect on acanthamoebae and tetrahymenae after 15 min under clean and dirty conditions. Our results suggest that benzalkonium chloride and sodium hypochlorite were effective against the three microorganisms at concentrations commonly applied in the food industry.
NASA Astrophysics Data System (ADS)
Park, Jong-Seok; Kuang, Jia; Gwon, Hui-Jeong; Lim, Youn-Mook; Jeong, Sung-In; Shin, Young-Min; Seob Khil, Myung; Nho, Young-Chang
2013-07-01
In this study, the characterization of zinc chloride incorporated into a poly(acrylic acid) (PAAc) hydrogel prepared by gamma-ray irradiation was investigated. Zinc chloride powder with different concentrations was dissolved in the PAAc solution, and it was crosslinked with gamma-ray irradiation. The effects of various parameters such as zinc ion concentration and irradiation doses on characteristics of the hydrogel formed were investigated in detail for obtaining an antibacterial wound dressing. In addition, the gel content, pH-sensitive (pH 4 or 7) swelling ratio, and UV-vis absorption spectra of the zinc particles in the hydrogels were characterized. Moreover, antibacterial properties of these new materials against Staphylococcus aureus and Escherichia coli strains were observed on solid growth media. The antibacterial tests indicated that the zinc chloride containing PAAc hydrogels have good antibacterial activity.
Concrete testing device provides substantial savings : fact sheet.
DOT National Transportation Integrated Search
2011-11-01
Current practices require a permeability test, ASTM C1202: "Standard Test Method for Electrical Indication of Concrete's Ability to resist Chloride Ion Penetration," for structures with potential salt water intrusion. The test is run at 56 days of ag...
Use of implantable pellets to administer low levels of methyl mercury to fish
Arnold, B.S.; Jagoe, C.H.; Gross, T.S.
1999-01-01
Implantable pellets of methyl mercury chloride were tested in Nile Tilapia (Oreochromis niloticus) to appraise the effectiveness of the method for chronic studies of mercury. Two dosing regimes of 15 and 1.5 grams/CH3HgCl pellet (test 1) and 1 and 0.1 grams/pellet (test 2-3) of methyl mercury chloride were used in three tests. Additional pellets containing only matrix were used as controls. The pellets were inserted into the peritoneal cavity along with a microchip for identification. Three methods of incision closure: sutures and two types of surgical glue, were tested. Pellets used in test one released the dose too fast, resulting in premature death of the fish. Results from test 2 and 3 show blood mercury concentrations over time and tissue levels at necropsy consistent with dose suggesting that this is a viable method of dosing fish.
Dark matter candidates: a ten-point test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taoso, Marco; Masiero, Antonio; Bertone, Gianfranco, E-mail: taoso@pd.infn.it, E-mail: bertone@iap.fr, E-mail: antonio.masiero@pd.infn.it
An extraordinarily rich zoo of non-baryonic dark matter candidates has been proposed over the last three decades. Here we present a ten-point test that a new particle has to pass in order to be considered a viable DM candidate. (I) Does it match the appropriate relic density? (II) Is it cold? (III) Is it neutral? (IV) Is it consistent with BBN? (V) Does it leave stellar evolution unchanged? (VI) Is it compatible with constraints on self-interactions? (VII) Is it consistent with direct DM searches? (VIII) Is it compatible with gamma-ray constraints? (IX) Is it compatible with other astrophysical bounds? (X)more » Can it be probed experimentally?.« less
A novel device for quantitative measurement of chloride concentration by fluorescence indicator
NASA Astrophysics Data System (ADS)
Wang, Junsheng; Wu, Xudong; Chon, Chanhee; Gonska, Tanja; Li, Dongqing
2012-02-01
Cystic fibrosis (CF) is a life-threatening genetic disease. At present, the common method for diagnosis of CF is to detect the chloride concentration in sweat using ion-selective electrodes. However, the current sweat testing methods require a relatively large quantity of sweat sample, at least 25 µL, which is very difficult to obtain, especially for newborns. This paper presents a new method and a new device for rapid detection of the chloride concentration from a small volume of solution. In this method, the chloride concentration is determined quantitatively by the fluorescence intensity of MQAE, a chloride ion fluorescent indicator. In this device, the sample is carried by a small piece of filter paper on a cover glass exposed to an UV LED light source. The resulting fluorescent signals are detected by a Si photodiode. Data acquisition and processing are accomplished by LabVIEW software in a PDA. Based on the Stern-Volmer relationship, the effects of different parameters on the fluorescence intensity were analyzed. The observed significant difference between 40 and 60 mM (the borderline of chloride concentration for CF) is discussed in this paper. The results show that detection can be completed within 10 s. The minimum detectable volume of the chloride solution is 1 μL. The novel method and the device are of great potential for CF diagnosis.
... Free Fetal DNA Cerebrospinal Fluid (CSF) Analysis Ceruloplasmin Chemistry Panels Chickenpox and Shingles Tests Chlamydia Testing Chloride ... 488-95. William Clarke. Contemporary Practice in Clinical Chemistry, 2nd Edition Paperback – February 4, 2011. ISBN-13: ...
Hubbart, J A; Kellner, E; Hooper, L W; Zeiger, S
2017-03-01
A nested-scale experimental watershed study was implemented to quantify loading and persistence of chloride in an urbanizing, mixed-land-use watershed. A Midwest USA (Missouri) watershed was partitioned into five sub-basins with contrasting dominant land use. Streamwater was tested for chloride concentration four days per week from October 2009 through May 2014 at each site. Monitoring sites included co-located gauging and climate stations recording variables at 30-minute intervals. Results indicate significant (p<0.01) differences in chloride concentrations and loading between sites. Loading consistently increased from the forested headwaters (average=507kgday -1 ) to primarily urban watershed terminus (average=7501kgday -1 ). Chloride concentrations were highest (average=83.9mgL -1 ) with the greatest frequency of acutely toxic conditions (i.e. 860mgL -1 ) mid-watershed. This finding is in-part attributable to the ratio of chloride application to streamflow volume (i.e. increasing flow volume with stream distance resulted in chloride dilution, offsetting increased percent urban land use with stream distance). Results highlight the important, yet often confounding, interactions between pollutant loading and flow dynamics. Chloride peaks occurred during late winter/early spring melting periods, implicating road salt application as the primary contributor to the chloride regime. Floodplain groundwater analysis indicated seasonal sink/source relationships between the stream and floodplain, which could contribute to chronic toxicity and persistent low Cl - concentrations in streamwater year-round. Results hold important implications for resource managers wishing to mitigate water quality and aquatic habitat degradation, and suggest important water quality limitations to stream restoration success in complex urban aquatic ecosystems. Copyright © 2017 Elsevier B.V. All rights reserved.
Kelly, Victoria R; Cunningham, Mary Ann; Curri, Neil; Findlay, Stuart E; Carroll, Sean M
2018-05-01
We used a GIS analysis of sodium and chloride concentrations in private water wells in a southeastern New York township to describe the pattern of distribution of road salt in aquifers tapped for drinking water. The primary source of road salt was sodium chloride, and sodium and chloride concentrations were significantly correlated ( = 0.80, < 0.01). Chloride concentrations in wells increased as the percentage of impervious surface cover (ISC) within a 250-m radius around wells increased ( = 0.87, < 0.01) and declined with increasing distance to the nearest road ( = 0.76, < 0.01). Wells that were located lower in elevation than the nearest road had higher concentrations of chloride than wells that were higher than the nearest road, but this occurred only when the nearest road was >30 m from the wells ( < 0.01). Chloride concentrations were not affected by well depth or adjacent road type (major or minor roads). Surface geology and hydrologic soil class had significant effects ( < 0.01) on chloride concentrations in wells, with porous surface geology types and well-drained soils having higher concentrations; these effects may be confounded by the fact that ISC was more likely to occur on these permeable surface geology and soil types. Hot and cold spot analysis revealed substantial unevenness in chloride concentrations. Results for sodium were similar to those for chloride. Overall, these results indicate that road salt contamination of groundwater is unevenly distributed and is affected by landscape factors that can be used to guide well testing and best management practices of deicing salt distribution. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Untiet, Verena; Kovermann, Peter; Gerkau, Niklas J; Gensch, Thomas; Rose, Christine R; Fahlke, Christoph
2017-02-01
Astrocytic volume regulation and neurotransmitter uptake are critically dependent on the intracellular anion concentration, but little is known about the mechanisms controlling internal anion homeostasis in these cells. Here we used fluorescence lifetime imaging microscopy (FLIM) with the chloride-sensitive dye MQAE to measure intracellular chloride concentrations in murine Bergmann glial cells in acute cerebellar slices. We found Bergmann glial [Cl - ] int to be controlled by two opposing transport processes: chloride is actively accumulated by the Na + -K + -2Cl - cotransporter NKCC1, and chloride efflux through anion channels associated with excitatory amino acid transporters (EAATs) reduces [Cl - ] int to values that vary upon changes in expression levels or activity of these channels. EAATs transiently form anion-selective channels during glutamate transport, and thus represent a class of ligand-gated anion channels. Age-dependent upregulation of EAATs results in a developmental chloride switch from high internal chloride concentrations (51.6 ± 2.2 mM, mean ± 95% confidence interval) during early development to adult levels (35.3 ± 0.3 mM). Simultaneous blockade of EAAT1/GLAST and EAAT2/GLT-1 increased [Cl - ] int in adult glia to neonatal values. Moreover, EAAT activation by synaptic stimulations rapidly decreased [Cl - ] int . Other tested chloride channels or chloride transporters do not contribute to [Cl - ] int under our experimental conditions. Neither genetic removal of ClC-2 nor pharmacological block of K + -Cl - cotransporter change resting Bergmann glial [Cl - ] int in acute cerebellar slices. We conclude that EAAT anion channels play an important and unexpected role in adjusting glial intracellular anion concentration during maturation and in response to cerebellar activity. GLIA 2017;65:388-400. © 2016 Wiley Periodicals, Inc.
Guerra, Lorenzo; D'Oria, Susanna; Favia, Maria; Castellani, Stefano; Santostasi, Teresa; Polizzi, Angela M; Mariggiò, Maria A; Gallo, Crescenzio; Casavola, Valeria; Montemurro, Pasqualina; Leonetti, Giuseppina; Manca, Antonio; Conese, Massimo
2017-07-01
The Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) potentiator ivacaftor (Kalydeco®) improves clinical outcome in G551D cystic fibrosis (CF) patients. Here, we have investigated whether ivacaftor has a clinical impact on non-G551D gating mutations and function of circulating leukocytes as well. Seven patients were treated with ivacaftor and evaluated at baseline, and at 1-3 and 6 months. Besides clinical and systemic inflammatory parameters, circulating mononuclear cells (MNC) were evaluated for CFTR-dependent chloride efflux by spectrofluorimetry, neutrophils for oxidative burst by cytofluorimetry and HVCN1 mRNA expression by real time PCR. Ivacaftor determined a significant decrease in sweat chloride concentrations at all time points during treatment. Body mass index (BMI), FEV 1 , and FVC showed an increasing trend. While C-reactive protein decreased significantly at 2 months, the opposite behavior was noticed for circulating monocytes. CFTR activity in MNC was found to increase significantly at 3 and 6 months. Neutrophil oxidative burst peaked at 2 months and then decreased to baseline. HVCN1 mRNA expression was significantly higher than baseline at 1-3 months and decreased after 6 months of treatment. The chloride efflux in MNC correlated positively with both FEV 1 and FVC. On the other hand, sweat chloride correlated positively with CRP and WBC, and negatively with both respiratory function tests. A cluster analysis confirmed that sweat chloride, FEV 1 , FVC, BMI, and MNC chloride efflux behaved as a single entity over time. In patients with non-G551D mutations, ivacaftor improved both chloride transport in sweat ducts and chloride efflux in MNC, that is, functions directly imputed to CFTR. © 2017 Wiley Periodicals, Inc.
New uses for calcium chloride solution as a mounting medium.
Herr, J M
1992-01-01
Fresh cross sections of stems (Psilotum nudum, Coleus blumei, and Pelargonium peltatum) and roots (Setcreasea purpurea) 120 microns thick were fixed in FPA50 (formalin: propionic acid: 50% ethanol, 5:5:90, v/v) for 24 hr and stored in 70% ethanol. The sections were transferred to water and then to 1% phloroglucin in 20% calcium chloride solution plus either hydrochloric, nitric, or lactic acid in the following ratios of phloroglucin-CaCl2 solution:acid: 25:4, 20:2, or 15:5. The sections were mounted on slides either in one of the three mixtures or in fresh 20% calcium chloride solution. A rapid reaction of the acid-phloroglucin with lignin produced a deep red color in tracheary elements and an orange-red color in sclerenchyma. Fixed and stored leaf pieces from Nymphaea odorata were autoclaved in lactic acid, washed in two changes of 95% ethanol, transferred to water, and treated with the three acid-phloroglucin-calcium chloride mixtures. The abundant astrosclereids stained an orange-red color similar to that of sclerenchyma in the sections. In addition, a new method is reported for specifically staining lignified tissues. When sections or leaf pieces are stained in aqueous 0.05% toluidine blue O, then placed in 20% calcium chloride solution, all tissues destain except those with lignified or partially lignified cell walls. Thus, toluidine blue O applied as described becomes a reliable specific test for lignin comparable to the acid-phloroglucin test.
Lead induced stress corrosion cracking of Alloy 690 in high temperature water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, K.K.; Lim, J.K.; Moriya, Shinichi
1995-12-31
Recent investigations of cracked steam generator tubes at nuclear power plants concluded that lead significantly contributed to cracking the Alloy 600 materials. In order to investigate the stress corrosion cracking (SCC) behavior of Alloy 690, slow strain rate tests (SSRT) and anodic polarization measurements were performed. The SSRTs were conducted in a lead-chloride solution (PbCl{sub 2}) and in a chloride but lead free solution (NaCl) at pH of 3 and 4.5 at 288 C. The anodic polarization measurements were carried out at 30 C using the same solutions as in SSRT. The SSRT results showed that Alloy 690 was susceptiblemore » to SCC in both solutions. In the lead chloride solution, cracking had slight dependence on lead concentration and pH. Cracking tend to increase with a higher lead concentration and a lower pH and was mainly intergranular and was to be a few tens to hundreds micrometers in length. In the chloride only solution, cracking was similar to the lead induced SCC. The results of anodic polarization measurement and electron probe micro analysis (EPMA) helped to understand lead induced SCC. Lead was a stronger active corrosive element but had a minor affect on cracking susceptibility of the alloy. While, chloride was quite different from lead effect to SCC. A possible mechanism of lead induced SCC of Alloy 690 was also discussed based on the test results.« less
Evaluating the compatibility of multi-functional and intensive urban land uses
NASA Astrophysics Data System (ADS)
Taleai, M.; Sharifi, A.; Sliuzas, R.; Mesgari, M.
2007-12-01
This research is aimed at developing a model for assessing land use compatibility in densely built-up urban areas. In this process, a new model was developed through the combination of a suite of existing methods and tools: geographical information system, Delphi methods and spatial decision support tools: namely multi-criteria evaluation analysis, analytical hierarchy process and ordered weighted average method. The developed model has the potential to calculate land use compatibility in both horizontal and vertical directions. Furthermore, the compatibility between the use of each floor in a building and its neighboring land uses can be evaluated. The method was tested in a built-up urban area located in Tehran, the capital city of Iran. The results show that the model is robust in clarifying different levels of physical compatibility between neighboring land uses. This paper describes the various steps and processes of developing the proposed land use compatibility evaluation model (CEM).
Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup
NASA Technical Reports Server (NTRS)
Harris, Patrick K.; Block, Nathan F.
2003-01-01
The MIL-STD-462 CS02 conducted susceptibility test setup includes an audio transformer, with the secondary used as an inductor, and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This, in turn, can damage flight hardware. Such an oscillation resulted in the catastrophic failure of an item tested in the Goddard Space Flight Center (GSFC) Large electromagnetic compatibility (EMC) Test Facility.
Compatibility testing of vacuum seal materials
NASA Astrophysics Data System (ADS)
Foster, P. A.; Rodin, W. A.
1993-05-01
Small scale materials compatibility testing was conducted for three elastomers considered for use as vacuum seal materials: Adiprene MOCA-cured; Adiprene Cyanacured; and Sylgard silastic rubber. The tests were conducted using orthogonal array designed experiments for each of the elastomers placed in contact with three materials commonly used during weapon disassembly operations: Duxseal, Sylgard 186 grease, and 2-propyl alcohol. The test results indicated that only the 2-propyl alcohol had a significant effect on the elastomer hardness and physical properties. The alcohol had the largest effect on the two Adiprene materials, and the silastic rubber was the least affected.
Lahnsteiner, Franz
2008-07-01
The sensitivity of the zebrafish embryo test, a test proposed for routine waste water control, was compared with the acute fish toxicity test, in the determination of six types of waste water and ten different chemicals. The waste water was sampled from the following industrial processes: paper and cardboard production, hide tanning, metal galvanisation, carcass treatment and utilisation, and sewage treatment. The chemicals tested were: dimethylacetamide, dimethylsulphoxide, cadmium chloride, cyclohexane, hydroquinone, mercuric chloride, nickel chloride, nonylphenol, resmethrin and sodium nitrite. For many of the test substances, the zebrafish embryo test and the acute fish toxicity test results showed high correlations. However, there were certain environmentally-relevant substances for which the results of the zebrafish embryo test and the acute fish toxicity test differed significantly, up to 10,000-fold (Hg(2+) > 150-fold difference; NO(2)(-) > 300-fold; Cd(2+) > 200-fold; resmethrin > 10,000-fold). For the investigated waste water samples and chemicals, the survival rate of the zebrafish embryos showed high variations between different egg samples, within the range of the EC50 concentration. Subsequently, 5-6 parallel assays were deemed to be the appropriate number necessary for the precise evaluation of the toxicity of the test substances. Also, it was found that the sensitivities of different ontogenetic stages to chemical exposure differed greatly. During the first 12 hours after fertilisation (4-cell stage to the 5-somite stage), the embryos reacted most sensitively to test substance exposure, whereas the later ontogenetic stages showed only slight or no response, indicating that the test is most sensitive during the first 24 hours post-fertilisation.
Stability of Dexmedetomidine in 0.9% Sodium Chloride in Two Types of Intravenous Infusion Bags.
Marquis, Kathleen; Hohlfelder, Benjamin; Szumita, Paul M
2017-01-01
Dexmedetomidine is a frequently used sedative in the critical care setting. It is commercially available as a 4-mg/mL premixed compound or as 200-mcg/2-mL vials that must be further diluted prior to administration. However, limited data exist regarding the stability of dexmedetomidine admixtures compounded from the 200-mcg/2-mL vials, particularly for durations greater than 48 hours. Therefore, we performed stability testing on compounded dexmedetomidine prepared in two types of intravenous infusion bags for 14 days. Dexmedetomidine is available as 200-mcg/2-mL vials for dilution, 80-mcg/20-mL single-dose vials, and as 200-mcg/50-mL and 400-mcg/100-mL glass bottles. The stability of dexmedetomidine admixtures has previously been tested for 48 hours. The purpose of this analysis was to test the stability of dexmedetomidine admixtures for 14 days. Six dexmedetomidine admixtures of 200 mcg/50 mL were compounded in polyvinyl chloride and non-polyvinyl chloride bags, three of which were stored under refrigeration and three of which were kept at room temperature. High-performance liquid chromatography testing was performed to determine the concentration at Days 1 through 14. Stability was determined by taking the mean concentration of samples taken from each bag. All samples were tested in duplicate. A sample was considered stable if the concentration was greater than 90% of the original concentration. All samples retained over 90% of the drug under their respective storage conditions for the duration of the study. At time 0, the concentration of dexmedetomidine was between 3.99 mcg/mL and 4.01 mcg/mL. On Day 14, the mean concentration was between 95.8% and 98.9%, depending on the bag type and storage condition. The pH remained between 4.7 and 5.8 during the study period as has previously been reported in the literature. Dexmedetomidine admixtures of 200 mcg/50 mL were stable in both polyvinyl chloride bags and non-polyvinyl chloride bags for 14 days under refrigeration and 48 hours at room temperature. This represents the longest time allowable under United States Pharmacopeia Chapter <797> without the need for sterility testing. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
2011-10-01
general terms the use of alternative paint strippers formulated with water, formic acids, benzyl alcohol, and peroxides . Facilities testing these...based on benzyl alcohol and peroxide .6 In this system the benzyl alcohol serves as a carrier to penetrate and soften the coating while the peroxide ...34 27. FTIR spectrum of the epoxy primer exposed to 20% benzyl alcohol in methylene chloride
Technical Feasibility Study of an Effective Low-Toxicity Obscurant Material
2012-08-01
2. REPORT TYPE FINAL 3. DATES COVERED (From - To) 04/2011 – 07/2012 4 . TITLE AND SUBTITLE 5a. CONTRACT NUMBER W912HQ-11-C-0034 Technical...6 4 Work Package 3 – Laboratory-scale tests...chemistry to sea-salt aerosol. 4 The major component of sea-salt is sodium chloride. Sodium chloride can be very simply generated by the combustion
Engineering and Design: Precipitation/Coagulation/Flocculation
2001-11-15
Flocculation 7-3 7-3 Jar Test Analysis 10-1 10-3 Alternating Flow Diversion Equalization System 11-1 11-1 Intermittent Flow Diversion System...EM 1110-1-4012 15 NOV 01 (2) Polyaluminum chloride (PAC), another aluminum derivative, is a partially hydrolyzed aluminum chloride solution...derived from natural products include starch, starch derivatives, proteins, and tannins (EPA, 1987). Of these, starch is the most widely used. The
DOT National Transportation Integrated Search
2000-04-01
The Coast Guard funded the National Telecommunications and Information Administration : (NTIA) to perform electromagnetic compatibility (EMC) tests between an ITU-R M. 825-3 : (Characteristics Of a Transponder System Using Digital Selective Calling T...
Seepage tests on No Name Creek, Colville Indian Reservation, Washington, May 12-13, 1977
MacNish, Robert D.
1977-01-01
To gain information for a water-management situation, a seepage test was performed on May 12-13, 1977, on a reach of No Name Creek on the Colville Indian Reservation in north-central Washington. On May 13, injection of a concentrated brine at the head of the test reach permitted chloride-concentration data to be combined with the discharge measurements made to define the pattern of gain and loss along the reach. Equations describing discharge and chloride mass balance were used to determine this pattern of gain and loss. The seepage tests showed that the streamflow gain of at least 0.58 cfs from springflow contributions was offset by losses of at least 0.59 cfs over the same reach. (Woodard-USGS)
Effect of Time on Gypsum-Impression Material Compatibility
NASA Astrophysics Data System (ADS)
Won, John Boram
The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were Alginot® (Kerr™), Position Penta Quick® (3M ESPE™) and Silgimix ® (Sultan Dental™). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobial® (Dentsply Caulk™) served as the control.
NASA Technical Reports Server (NTRS)
Campbell, Colin; Cox, Marlon; Meginnis, Carly; Falconi, Eric
2017-01-01
The Variable Oxygen Regulator (VOR), a stepper actuated two-stage mechanical regulator, is being developed for the purpose of serving as the Primary Oxygen Regulator (POR) and Secondary Oxygen Regulator (SOR) within the Advanced EMU PLSS, now referred to as the xEMU and xPLSS. Three prototype designs have been fabricated and tested as part of this development. Building upon the lessons learned from the 35 years of Shuttle/ISS EMU Program operation including the fleet-wide EMU Secondary Oxygen Pack (SOP) contamination failure that occurred in 2000, the VOR is being analyzed, designed, and tested for oxygen compatibility with controlled Non-Volatile Residue (NVR) and a representative worst-case hydro-carbon system contamination event (>100mg/sq ft dodecane). This paper discusses the steps taken in testing of VOR 2.0 with for oxygen compatibility and then discusses follow-on design changes implemented in the VOR 3.0 (3rd prototype) as a result.
Advanced intermediate temperature sodium–nickel chloride batteries with ultra-high energy density
Li, Guosheng; Lu, Xiaochuan; Kim, Jin Y.; Meinhardt, Kerry D.; Chang, Hee Jung; Canfield, Nathan L.; Sprenkle, Vincent L.
2016-01-01
Sodium-metal halide batteries have been considered as one of the more attractive technologies for stationary electrical energy storage, however, they are not used for broader applications despite their relatively well-known redox system. One of the roadblocks hindering market penetration is the high-operating temperature. Here we demonstrate that planar sodium–nickel chloride batteries can be operated at an intermediate temperature of 190 °C with ultra-high energy density. A specific energy density of 350 Wh kg−1, higher than that of conventional tubular sodium–nickel chloride batteries (280 °C), is obtained for planar sodium–nickel chloride batteries operated at 190 °C over a long-term cell test (1,000 cycles), and it attributed to the slower particle growth of the cathode materials at the lower operating temperature. Results reported here demonstrate that planar sodium–nickel chloride batteries operated at an intermediate temperature could greatly benefit this traditional energy storage technology by improving battery energy density, cycle life and reducing material costs. PMID:26864635
Jin, Byung-Ju; Ko, Eun-A; Namkung, Wan; Verkman, A S
2013-10-07
We previously developed cell-based kinetics assays of chloride channel modulators utilizing genetically encoded yellow fluorescent proteins. Fluorescence platereader-based high-throughput screens yielded small-molecule activators and inhibitors of the cAMP-activated chloride channel CFTR and calcium-activated chloride channels, including TMEM16A. Here, we report a microfluidics platform for single-shot determination of concentration-activity relations in which a 1.5 × 1.5 mm square area of adherent cultured cells is exposed for 5-10 min to a pseudo-logarithmic gradient of test compound generated by iterative, two-component channel mixing. Cell fluorescence is imaged following perfusion with an iodide-containing solution to give iodide influx rate at each location in the image field, thus quantifying modulator effects over a wide range of concentrations in a single measurement. IC50 determined for CFTR and TMEM16A activators and inhibitors by single-shot microfluidics were in agreement with conventional plate reader measurements. The microfluidics approach developed here may accelerate the discovery and characterization of chloride channel-targeted drugs.
Calcium phosphate stabilization of fly ash with chloride extraction.
Nzihou, Ange; Sharrock, Patrick
2002-01-01
Municipal solid waste incinerator by products include fly ash and air pollution control residues. In order to transform these incinerator wastes into reusable mineral species, soluble alkali chlorides must be separated and toxic trace elements must be stabilized in insoluble form. We show that alkali chlorides can be extracted efficiently in an aqueous extraction step combining a calcium phosphate gel precipitation. In such a process, sodium and potassium chlorides are obtained free from calcium salts, and the trace metal ions are immobilized in the calcium phosphate matrix. Moderate calcination of the chemically treated fly ash leads to the formation of cristalline hydroxylapatite. Fly ash spiked with copper ions and treated by this process shows improved stability of metal ions. Leaching tests with water or EDTA reveal a significant drop in metal ion dissolution. Hydroxylapatite may trap toxic metals and also prevent their evaporation during thermal treatments. Incinerator fly ash together with air pollution control residues, treated by the combined chloride extraction and hydroxylapatite formation process may be considered safe to use as a mineral filler in value added products such as road base or cement blocks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, R.; Peters, T.
2011-11-01
Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and the Savannah River Site (SRS) HB-Line Facility designed, developed, tested, and successfully deployed a production-scale system for the distillation of sodium chloride (NaCl) and potassium chloride (KCl) from plutonium oxide (PuO{sub 2}). Subsequent efforts adapted the vacuum salt distillation (VSD) technology for the removal of chloride and fluoride from less-volatile halide salts at the same process temperature and vacuum. Calcium chloride (CaCl{sub 2}), calcium fluoride (CaF{sub 2}), and plutonium fluoride (PuF{sub 3}) were of particular concern. To enable the use of the same operating conditions for themore » distillation process, SRNL employed in situ exchange reactions to convert the less-volatile halide salts to compounds that facilitated the distillation of halide without removal of plutonium. SRNL demonstrated the removal of halide from CaCl{sub 2}, CaF{sub 2} and PuF{sub 3} below 1000 C using VSD technology.« less
Rare mutation in the SLC26A3 transporter causes life-long diarrhoea with metabolic alkalosis
Abou Ziki, Maen D; Verjee, Mohamud A
2015-01-01
SLC26A3, a chloride/bicarbonate transporter mainly expressed in the intestines, plays a pivotal role in chloride absorption. We present a 23-year-old woman with a history of congenital chloride diarrhoea (CCD) and renal transplant who was admitted for rehydration and treatment of acute kidney injury after she presented with an acute diarrhoeal episode. Laboratory investigations confirmed metabolic alkalosis and severe hypochloraemia, consistent with her underlying CCD. This contrasts with most other forms of diarrhoea, which are normally associated with metabolic acidosis. Genetic testing was offered and revealed a homozygous non-sense mutation in SLC26A3 (Gly-187-Stop). This loss-of-function mutation results in bicarbonate retention in the blood and chloride loss into the intestinal lumen. Symptomatic management with daily NaCl and KCl oral syrups was supplemented with omeprazole therapy. The loss of her own kidneys is most likely due to crystal-induced nephropathy secondary to chronic volume contraction and chloride depletion. This case summarises the pathophysiology and management of CCD. PMID:25568271
Study of chloride ion transport of composite by using cement and starch as a binder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Armynah, Bidayatul; Halide, Halmar; Zahrawani,
This study presents the chemical bonding and the structural properties of composites from accelerator chloride test migration (ACTM). The volume fractions between binder (cement and starch) and charcoal in composites are 20:80 and 60:40. The effect of the binder to the chemical composition, chemical bonding, and structural properties before and after chloride ion passing through the composites was determined by X-ray fluorescence (XRF), by Fourier transform infra-red (FTIR), and x-ray diffraction (XRD), respectively. From the XRD data, XRF data, and the FTIR data shows the amount of chemical composition, the type of binding, and the structure of composites are dependingmore » on the type of binder. The amount of chloride migration using starch as binder is higher than that of cement as a binder due to the density effects.« less
High-temperature corrosion of metals in the salt and metallic melts containing rare earths
NASA Astrophysics Data System (ADS)
Karpov, V. V.; Abramov, A. V.; Zhilyakov, A. Yu.; Belikov, S. V.; Volkovich, V. A.; Polovov, I. B.; Rebrin, O. I.
2016-09-01
A complex of independent methods was employed to study the corrosion resistance of molybdenum, zirconium, tantalum and tungsten in chloride, chloride-fluoride and fluoride-oxide melts based on LiCl, CaCl2, NaCl- KCl, LiF, and containing rare earths. Tests were conducted for 30 h at 750-1050 °C. The metals showed excellent corrosion resistance in fused chlorides (the corrosion rates were below 0.0005 g/(m2 h). Despite the presence of chemically active fluoride ions in the chloride-fluoride melts, the metals studied also showed very low corrosion rates, except molybdenum, for which the rate of corrosion was 0,8 g/(m2 h). The corrosion resistance of tantalum was considerably reduced in the fluoride-oxide melts; the corrosion rate was over 1 g/(m2 h) corresponding to the 8-th grade of stability and placing tantalum to the group of "low stability" materials.
NASA Astrophysics Data System (ADS)
Yamaguchi, Keisuke; Ueda, Takao; Nanasawa, Akira
As a new rehabilitation technique for recovery both of loading ability and durability of concrete structures deteriorated by chloride attack, desalination (electrochemical chloride removal technique from concrete) using CFRP composite electrode bonding to concrete has been developed. In this study, basic application was tried using small RC specimens, and also application to the large-scale RC beams deteriorated by the chloride attack through the long-term exposure in the outdoors was investigated. As the result of bending test of treated specimens, the decrease of strengthening effect with the electrochemical treatment was observed in the case of small specimens using low absorption rate resin for bonding, on the other hand, in the case of large-scale RC beam using 20% absorption rate resin for bonding CFRP composite electrode, enough strengthening effect was obtained by the bending failure of RC beam with the fracture of CFRP board.
DESCRIPTIVE ANALYSIS OF DIVALENT SALTS
YANG, HEIDI HAI-LING; LAWLESS, HARRY T.
2005-01-01
Many divalent salts (e.g., calcium, iron, zinc), have important nutritional value and are used to fortify food or as dietary supplements. Sensory characterization of some divalent salts in aqueous solutions by untrained judges has been reported in the psychophysical literature, but formal sensory evaluation by trained panels is lacking. To provide this information, a trained descriptive panel evaluated the sensory characteristics of 10 divalent salts including ferrous sulfate, chloride and gluconate; calcium chloride, lactate and glycerophosphate; zinc sulfate and chloride; and magnesium sulfate and chloride. Among the compounds tested, iron compounds were highest in metallic taste; zinc compounds had higher astringency and a glutamate-like sensation; and bitterness was pronounced for magnesium and calcium salts. Bitterness was affected by the anion in ferrous and calcium salts. Results from the trained panelists were largely consistent with the psychophysical literature using untrained judges, but provided a more comprehensive set of oral sensory attributes. PMID:16614749
Passive particle dosimetry. [silver halide crystal growth
NASA Technical Reports Server (NTRS)
Childs, C. B.
1977-01-01
Present methods of dosimetry are reviewed with emphasis on the processes using silver chloride crystals for ionizing particle dosimetry. Differences between the ability of various crystals to record ionizing particle paths are directly related to impurities in the range of a few ppm (parts per million). To understand the roles of these impurities in the process, a method for consistent production of high purity silver chloride, and silver bromide was developed which yields silver halides with detectable impurity content less than 1 ppm. This high purity silver chloride was used in growing crystals with controlled doping. Crystals were grown by both the Czochalski method and the Bridgman method, and the Bridgman grown crystals were used for the experiments discussed. The distribution coefficients of ten divalent cations were determined for the Bridgman crystals. The best dosimeters were made with silver chloride crystals containing 5 to 10 ppm of lead; other impurities tested did not produce proper dosimeters.
NASA Astrophysics Data System (ADS)
Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.
The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.
Double Retort System for Materials Compatibility Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Munne; EV Carelli
2006-02-23
With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the Space Nuclear Power Plant (SNPP) for Project Prometheus (References a and b) there was a need to investigate compatibility between the various materials to be used throughout the SNPP. Of particular interest was the transport of interstitial impurities from the nickel-base superalloys, which were leading candidates for most of the piping and turbine components to the refractory metal alloys planned for use in the reactor core. This kind of contaminationmore » has the potential to affect the lifetime of the core materials. This letter provides technical information regarding the assembly and operation of a double retort materials compatibility testing system and initial experimental results. The use of a double retort system to test materials compatibility through the transfer of impurities from a source to a sink material is described here. The system has independent temperature control for both materials and is far less complex than closed loops. The system is described in detail and the results of three experiments are presented.« less
Kelly-Cirino, Cassandra D; Curry, Patricia S; Marola, Jamie L; Helstrom, Niels K; Salfinger, Max
2016-11-01
OMNIgene®•SPUTUM (OM-S) is a sputum transport reagent designed to work with all tuberculosis diagnostics and eliminate the need for cold chain. The aim of this preliminary study was to assess the compatibility of OM-S-treated sputum with the Xpert® MTB/RIF assay. Fifty-five characterized sputa from the FIND TB Specimen Bank were used. Compatibility of OM-S was assessed for both Xpert sample preparation methods: H.1 protocol (sediment, n=25) and H.2 protocol (direct expectorate, n=30). All controls were prepared using the H.2 protocol. Results revealed 100% concordance of MTB/RIF results for all except the low-positive group in the H.1 study arm (n=10; 88% concordance). OM-S-treated sputa were successful in both protocols; if the Xpert buffer is not added during the H.2 procedure, sample viscosity may require repeat testing. Using OM-S could offer users flexibility in clinical testing algorithms. Larger compatibility studies are warranted, particularly with respect to MTB/RIF results for low-positive samples. Copyright © 2016 Elsevier Inc. All rights reserved.
Datta, Naomi; Olarte, J.
1974-01-01
All 17 Salmonella typhi strains tested from the epidemic in Mexico carried R factors of compatibility group H, conferring resistance to chloramphenicol, streptomycin, tetracycline, and sulfonamides. Some S. typhi strains carried, in addition, non-conjugative, ampicillin resistance plasmids and R factors of the I or A–C complex. All 20 Shigella dysenteriae 1 strains tested of epidemic origin carried O-group R factors. Ampicillin resistance in S. dysenteriae 1 was not proved to be plasmid borne. R factors of group H were not identified in any of the tested Mexican isolates other than S. typhi, but R factors of group O were identified in Escherichia coli, Shigella flexneri, and one strain of S. typhi, as well as in the epidemic S. dysenteriae. An R factor was identified which seemed to have two compatibility specificities, groups Iω and O. PMID:4599123
NASA Astrophysics Data System (ADS)
Eun, H. C.; Choi, J. H.; Kim, N. Y.; Lee, T. K.; Han, S. Y.; Lee, K. R.; Park, H. S.; Ahn, D. H.
2016-11-01
The pyrochemical process, which recovers useful resources (U/TRU metals) from used nuclear fuel using an electrochemical method, generates LiCl-KCl eutectic waste salt containing radioactive rare earth chlorides (RECl3). It is necessary to develop a simple process for the treatment of LiCl-KCl eutectic waste salt in a hot-cell facility. For this reason, a reactive distillation process using a chemical agent was achieved as a method to separate rare earths from the LiCl-KCl waste salt. Before conducting the reactive distillation, thermodynamic equilibrium behaviors of the reactions between rare earth (Nd, La, Ce, Pr) chlorides and the chemical agent (K2CO3) were predicted using software. The addition of the chemical agent was determined to separate the rare earth chlorides into an oxide form using these equilibrium results. In the reactive distillation test, the rare earth chlorides in LiCl-KCl eutectic salt were decontaminated at a decontamination factor (DF) of more than 5000, and were mainly converted into oxide (Nd2O3, CeO2, La2O3, Pr2O3) or oxychloride (LaOCl, PrOCl) forms. The LiCl-KCl was purified into a form with a very low concentration (<1 ppm) for the rare earth chlorides.
Antarctic polar stratospheric aerosols: The roles of nitrates, chlorides and sulfates
NASA Technical Reports Server (NTRS)
Pueschel, R. F.; Snetsinger, K. G.; Goodman, J. K.; Ferry, G. V.; Oberbeck, V. R.; Verma, S.; Fong, W.
1988-01-01
Nitric and hydrochloric acids have been postulated to condense in the winter polar stratosphere to become an important component of polar stratospheric clouds. One implication is that the removal of NO(y) from the gas phase by this mechanism allows high Cl(x) concentrations to react with O3, because the formation of ClNO3 is inhibited. Contributions of NO3 and Cl to the stratospheric aerosol were determined during the 1987 Airborne Antarctic Ozone Experiment by testing for the presence of nitrates and chlorides in the condensed phase. Aerosol particles were collected on four 500 micron diameter gold wires, each pretreated differently to give results that were specific to certain physical and chemical aerosol properties. One wire was carbon-coated for concentration and size analyses by scanning electron microscopy; X-ray energy dispersive analyses permitted the detection of S and Cl in individual particles. Three more wires were coated with Nitron, barium chloride and silver nitrate, respectively, to detect nitrate, sulfate and chloride in aerosol particles. All three ions, viz., sulfates, nitrates and chlorides were detected in the Antarctic stratospheric aerosol. In terms of number concentrations, the aerosol was dominated by sulfates, followed by chlorides and nitrates. An inverse linear regression can be established between nitrate concentrations and ozone mixing ratio, and between temperature and nitrates.
Production of N2O5 and ClNO2 through Nocturnal Processing of Biomass-Burning Aerosol.
Ahern, Adam T; Goldberger, Lexie; Jahl, Lydia; Thornton, Joel; Sullivan, Ryan C
2018-01-16
Biomass burning is a source of both particulate chloride and nitrogen oxides, two important precursors for the formation of nitryl chloride (ClNO 2 ), a source of atmospheric oxidants that is poorly prescribed in atmospheric models. We investigated the ability of biomass burning to produce N 2 O 5 (g) and ClNO 2 (g) through nocturnal chemistry using authentic biomass-burning emissions in a smog chamber. There was a positive relationship between the amount of ClNO 2 formed and the total amount of particulate chloride emitted and with the chloride fraction of nonrefractory particle mass. In every fuel tested, dinitrogen pentoxide (N 2 O 5 ) formed quickly, following the addition of ozone to the smoke aerosol, and ClNO 2 (g) production promptly followed. At atmospherically relevant relative humidities, the particulate chloride in the biomass-burning aerosol was rapidly but incompletely displaced, likely by the nitric acid produced largely by the heterogeneous uptake of N 2 O 5 (g). Despite this chloride acid displacement, the biomass-burning aerosol still converted on the order of 10% of reacted N 2 O 5 (g) into ClNO 2 (g). These experiments directly confirm that biomass burning is a potentially significant source of atmospheric N 2 O 5 and ClNO 2 to the atmosphere.
Influence of reinforcement mesh configuration for improvement of concrete durability
NASA Astrophysics Data System (ADS)
Pan, Chong-gen; Jin, Wei-liang; Mao, Jiang-hong; Zhang, Hua; Sun, Li-hao; Wei, Dong
2017-10-01
Steel bar in concrete structures under harsh environmental conditions, such as chlorine corrosion, seriously affects its service life. Bidirectional electromigration rehabilitation (BIEM) is a new method of repair technology for reinforced concrete structures in such chloride corrosion environments. By applying the BIEM, chloride ions can be removed from the concrete and the migrating corrosion inhibit can be moved to the steel surface. In conventional engineering, the concrete structure is often configured with a multi-layer steel mesh. However, the effect of the BIEM in such structures has not yet been investigated. In this paper, the relevant simulation test is carried out to study the migration law of chloride ions and the migrating corrosion inhibitor in a concrete specimen with complex steel mesh under different energizing modes. The results show that the efficiency of the BIEM increases 50% in both the monolayer steel mesh and the double-layer steel mesh. By using the single-sided BIEM, 87% of the chloride ions are removed from the steel surface. The different step modes can affect the chloride ion removal. The chloride ions within the range of the reinforcement protective cover are easier to be removed than those in the concrete between the two layers of steel mesh. However, the amount of migrating corrosion inhibitor is larger in the latter circumstances.
compare the effects of elevated temperature on 801-finish glass. The strength qualities at 75 F of Owens - Corning ECG-140 continuous-filament roving glass...with an 801 epoxy compatible finish and the same glass with an HTS epoxy compatible finish were tested. The strength qualities of Owens - Corning ECG
NASA Astrophysics Data System (ADS)
Kahraman, R.; Kahn, K. A.; Ali, S. A.; Hamid, S. H.; Sahin, A. Z.
1998-12-01
Thermal, morphological, and mechanical properties of composites of a liquid crystalline copolymer (LCP) poly(terephthaloyl chloride)-co-(p,p’-dihydroxydiphenyl sulfone) with polystyrene (PS) and sulfonated polystyrene (SPS) are presented and discussed. Sulfonation of polystyrene was expected to improve the interfacial adhesion by introducing hydrogen bonding in the LCP/PS system. The degree of sulfonation was 11 %. The incompatibility (lack of proper interfacial adhesion) of the LCP/PS system resulted in sharp decrease in the composite tensile strength with LCP addition. The performance of the system did not change when processed at a higher temperature (270 °C instead of 225 °C). While a composite plate of 25% LCP/PS could not be fabricated, it was possible for LCP/SPS (processed at 215 °C), indicating some improvement in interfacial bonding by sulfonation. Sulfonation of PS resulted in fracture with some degree of plastic deformation for pure SPS matrix and also the LCP/SPS system with the lowest LCP content (1 wt%), whereas plastic deformation was not observed for PS used as received. The strength of the LCP/SPS system also decreased with increase in LCP content, indicating that 11% sulfonation is not sufficient to introduce significant compatibility, but it was not as dramatic as that for LCP/PS. The performance of the LCP/SPS system was not affected significantly by heat treatment at the process temperature.
Reinforcement of natural rubber latex using lignocellulosic nanofibers isolated from spinifex grass.
Hosseinmardi, Alireza; Annamalai, Pratheep K; Wang, Lianzhou; Martin, Darren; Amiralian, Nasim
2017-07-13
Reinforcement of natural rubber (NR) using nanofillers often results in an enhancement of the tensile strength, but at the expense of elongation at break and toughness. In this study, with the objective of strengthening NR without compromising its compliance, we investigate the reinforcement efficiency of a series of cellulose nanofibers (CNF) with variations in residual hemicellulose, lignin and therefore surface chemistry. Different types of high aspect ratio CNF isolated from Triodia pungens (T. pungens), an Australian arid grass commonly known as spinifex, were added at 0.1-2 wt% loadings into a pre-vulcanized NR latex. CNF/NR nanocomposites then were benchmarked against NR nanocomposites incorporating a well-known wood-derived CNF. It was found that the presence of residual lignin and hemicellulose, and the pretreatment with a deep eutectic solvent, a mixture of choline chloride and urea (CCU), could increase the compatibility of CNF with the NR matrix, while still enabling stability and handling of the colloidal latex mixture. Incorporation of 0.5 and 0.1 wt% of the sodium hydroxide treated CNF and choline chloride/urea treated CNF into the NR latex showed respectively 11 and 17% enhancement in tensile stress, and importantly without compromising viscoelastic properties; while addition of 0.1 wt% wood-derived CNF resulted in 18% decrease in both tensile stress and strain coupled with more pronounced latex stiffening.
Whiting, S J; Anderson, D J; Weeks, S J
1997-05-01
An acute load test was used to test the influence of dietary factors on urinary calcium excretion. In study 1, 10 fasting premenopausal women consumed test meals providing a moderate amount of protein (MP; 23 g), MP plus 23 mmol KHCO3 (MP+K), MP plus 23 mmol NaCl (MP+Na), and a high amount of protein (HP; 53 g), HP plus 70 mmol KHCO3 (HP+K), and HP plus 70 mmol NaCl (HP+Na). Protein was casein:lactalbumin (80:20), except for the treatments with added sodium chloride, to which only casein was added. In study 2, the effects of HP and HP plus 50 mmol KHCO3 (HP+K) were compared with those of MP or MP plus 7.5 mmol phosphate (MP+Pi), equaling the additional phosphate of HP, in 10 adult men. Subjects completed all treatments in random order. In study 1, the peak of calcium excretion was at 3 h for all treatments, except for HP+K, which indicated an acute hypocalciuric effect of potassium. Unexpectedly, there was no hypercalciuric effect of adding sodium chloride, nor was urine sodium increased. In study 2, calcium excretion was significantly higher with HP than with MP+Pi but not with MP at 3 h, indicating an acute hypercalciuric effect of protein alone. A hypocalciuric effect of potassium (HP+K compared with HP) but not of phosphate (MP compared with MP+Pi) was seen. An acute load test measuring changes 3 h postload was appropriate for examining the calciuric effects of protein and potassium bicarbonate, but not those of sodium chloride or phosphate in adults.
... You may be surprised to learn how much sodium is in many foods. Sodium, including sodium chloride ... foods with little or no salt. Test your sodium smarts by answering these 10 questions about which ...
Detergent-compatible proteases: microbial production, properties, and stain removal analysis.
Niyonzima, Francois Niyongabo; More, Sunil
2015-01-01
Proteases are one of the most important commercial enzymes used in various industrial domains such as detergent and leather industries. The alkaline proteases as well as other detergent-compatible enzymes such as lipases and amylases serve now as the key components in detergent formulations. They break down various stains during fabric washing. The search for detergent-compatible proteases with better properties is a continuous exercise. The current trend is to use detergent-compatible proteases that are stable over a wide temperature range. Although the proteases showing stability at elevated pH have the capacity to be used in detergent formulations, their usage can be significant if they are also stable and compatible with detergent and detergent ingredients, and also able to remove protein stains. Despite the existence of some reviews on alkaline proteases, there is no specification for the use of alkaline proteases as detergent additives. The present review describes the detergent-compatible proteases tested as detergent additives. An overview was provided for screening, optimization, purification, and properties of detergent compatible proteases, with an emphasis on the stability and compatibility of the alkaline proteases with the detergent and detergent compounds, as well as stain removal examination methods.
Design of a safe cylindrical lithium/thionyl chloride cell
NASA Technical Reports Server (NTRS)
Johnson, D. H.
1983-01-01
Cell design criteria were established which can result in a safe lithium/thionyl chloride cell. A cell vent, a low area internal anode cell, cell balance and composition of the cathode-electrolyte solution were found to be important factors in the design of a safe cell. In addition to routine testing, both undischarged and discharged cells were subjected to electrical abuse, environmental abuse and mechanical abuse without disassembly.
Inactivation of Viruses by Benzalkonium Chloride
Armstrong, J. A.; Froelich, E. J.
1964-01-01
Benzalkonium chloride (as Roccal or Zephiran) was found to inactivate influenza, measles, canine distemper, rabies, fowl laryngotracheitis, vaccinia, Semliki Forest, feline pneumonitis, meningopneumonitis, and herpes simplex viruses after 10 min of exposure at 30 C or at room temperature. Poliovirus and encephalomyocarditis virus were not inactivated under the same conditions. It was concluded that all viruses tested were sensitive except members of the picorna group. The literature was reviewed. PMID:4288740
Tellurium: A new sensitive test
Lakin, H.W.; Thompson, C.E.
1963-01-01
A new, extremely sensitive method for the quantitative determination of tellurium is based on the induced precipitation of elemental gold from a 6N HCl solution containing gold chloride, cupric chloride, and hypophosphorous acid; the amount of gold reduced is proportional to the amount of tellurium present. As little as 1 nanogram (1 ?? 70-9 g) of tellurium gives a measurable reaction with 1 mg of gold in 50 ml of solution.
Experimental Polyvinyl Chloride (PVC) Roofing: Field Test Results.
1987-02-01
construction. These were the single-ply membranes of the ethylene-propylene-diene monomer ( EPDM ) and polyvinyl chloride (PVC) types, and the sprayed-in-place...polyurethane foam (PUF) with an elastomeric coating. EPDM and PUF roofs were constructed in 19802 and the PVC roofs were completed during summer 1983...faced isocyanu- rate foam board in two layers . Roofing systems were installed loose-laid and ballasted. Specific membrane materials were Plymouth
Ebeling, J.M.; Sibrell, P.L.; Ogden, S.R.; Summerfelt, S.T.
2003-01-01
An evaluation of two commonly used coagulation-flocculation aids (alum and ferric chloride) was conducted for the supernatant overflow from settling cones used to treat the effluent from microscreen filters in an intensive recirculating aquaculture system. In addition to determining the effectiveness of these aids in removing both suspended solids and phosphorus, a systematic testing of the variables normally encountered in the coagulation-flocculation process was performed. Tests were carried out to evaluate the dosages and conditions (mixing and flocculation stirring speeds, durations, and settling times) required to achieve optimum waste capture. The orthophosphate removal efficiency for alum and ferric chloride were 89 and 93%, respectively, at a dosage of 90 mg/l. Optimum turbidity removal was achieved with a 60 mg/l dosage for both alum and ferric chloride. Both alum and ferric. chloride demonstrated excellent removal of suspended solids from initial TSS values of approximately 100-10 mg/l at a dosage of 90 mg/l. Flocculation and mixing speed played only a minor role in the removal efficiencies for both orthophosphates and suspended solids. Both coagulation-flocculation aids also exhibited excellent settling characteristics, with the majority of the floc quickly settling out in the first 5 min. ?? 2003 Elsevier B.V. All rights reserved.
Nikiforov, Leonid A; Okhlopkova, Tatinana A; Kapitonova, Iullia V; Sleptsova, Sardana A; Okhlopkova, Aitalina A; Shim, Ee Le; Cho, Jin-Ho
2017-12-05
In this study, the reinforcement of ultrahigh-molecular-weight polyethylene (UHMWPE) with biotite was investigated. The biotite filler was mechanically activated with different dry surfactants to improve its compatibility with UHMWPE and decrease agglomeration among biotite particles. Alkyldimethylbenzylammonium chloride (ADBAC) and cetyltrimethylammonium bromide (CTAB) were selected as cationic surfactants. The tensile strength of composites containing 1 wt % of CTAB-treated biotite was increased by 30% relative to those with untreated biotite, but was unchanged with ADBAC treatment of the same biotite content. The stereochemistry of the surfactant may be critical to the composite structure and mechanical properties of the material. The stereochemistry of CTAB was preferable to that of ADBAC in enhancing mechanical properties because the stereochemistry of ADBAC impedes favorable interactions with the biotite surface during mechanical activation.
Redey, L.I.; Vissers, D.R.; Prakash, J.
1994-02-01
An electrochemical cell is described having a bimodal positive electrode, a negative electrode of an alkali metal, and a compatible electrolyte including an alkali metal salt molten at the cell operating temperature. The positive electrode has an electrochemically active layer of at least one transition metal chloride at least partially present as a charging product, and additives of bromide and/or iodide and sulfur in the positive electrode or the electrolyte. Electrode volumetric capacity is in excess of 400 Ah/cm[sup 3]; the cell can be 90% recharged in three hours and can operate at temperatures below 160 C. There is also disclosed a method of reducing the operating temperature and improving the overall volumetric capacity of an electrochemical cell and for producing a positive electrode having a BET area greater than 6[times]10[sup 4] cm[sup 2]/g of Ni. 8 figures.
Redey, Laszlo I.; Vissers, Donald R.; Prakash, Jai
1994-01-01
An electrochemical cell having a bimodal positive electrode, a negative electrode of an alkali metal, and a compatible electrolyte including an alkali metal salt molten at the cell operating temperature. The positive electrode has an electrochemically active layer of at least one transition metal chloride at least partially present as a charging product, and additives of bromide and/or iodide and sulfur in the positive electrode or the electrolyte. Electrode volumetric capacity is in excess of 400 Ah/cm.sup.3 ; the cell can be 90% recharged in three hours and can operate at temperatures below 160.degree. C. There is also disclosed a method of reducing the operating temperature and improving the overall volumetric capacity of an electrochemical cell and for producing a positive electrode having a BET area greater than 6.times.10.sup.4 cm.sup.2 /g of Ni.
Redey, Laszlo I.; Vissers, Donald R.; Prakash, Jai
1996-01-01
An electrochemical cell having a bimodal positive electrode, a negative electrode of an alkali metal, and a compatible electrolyte including an alkali metal salt molten at the cell operating temperature. The positive electrode has an electrochemically active layer of at least one transition metal chloride at least partially present as a charging product, and additives of bromide and/or iodide and sulfur in the positive electrode or the electrolyte. Electrode volumetric capacity is in excess of 400 Ah/cm.sup.3 ; the cell can be 90% recharged in three hours and can operate at temperatures below 160.degree. C. There is also disclosed a method of reducing the operating temperature and improving the overall volumetric capacity of an electrochemical cell and for producing a positive electrode having a BET area greater than 6.times.10.sup.4 cm.sup.2 /g of Ni.
Redey, L.I.; Vissers, D.R.; Prakash, J.
1996-07-16
An electrochemical cell is described having a bimodal positive electrode, a negative electrode of an alkali metal, and a compatible electrolyte including an alkali metal salt molten at the cell operating temperature. The positive electrode has an electrochemically active layer of at least one transition metal chloride at least partially present as a charging product, and additives of bromide and/or iodide and sulfur in the positive electrode or the electrolyte. Electrode volumetric capacity is in excess of 400 Ah/cm{sup 3}; the cell can be 90% recharged in three hours and can operate at temperatures below 160 C. There is also disclosed a method of reducing the operating temperature and improving the overall volumetric capacity of an electrochemical cell and for producing a positive electrode having a BET area greater than 6{times}10{sup 4}cm{sup 2}/g of Ni. 6 figs.
NASA Astrophysics Data System (ADS)
Crumley, R. L.; MacDowall, R. D.; Hardin, J. E.; Burke, A. F.
1989-04-01
This report is concerned with the test and evaluation of the ETX-I electric test vehicle, which is a Mercury LN7 retrofitted with the single-shaft ac electric powertrain developed by Ford and General Electric under contract to the U.S. Department of Energy (DOE) during the period 1982 to 1985. The lead-acid battery used in the ETX-I was developed by Lucas Chloride Electric Vehicle (EV) Systems (LCEVS) as part of the same DOE contract. Extensive tests of the powertrain and battery were done by General Electric and Lucas Chloride before they were integrated into the ETX-I test vehicle by Ford. Ford did limited testing of the ETX-I vehicle on a chassis dynamometer to determine the energy consumption of the powertrain for several driving schedules before the vehicle was shipped to INEL for complete dynamometer testing. Ford also performed track tests with the ETX-I to determine its acceleration performance characteristics.
Lüttge, U
1966-03-01
The transport of chloride in isolated tissue from Nepenthes pitchers was investigated using (36)Cl(-), an Aminco-Cotlove chloride-titrator for the determinations of Cl(-) concentrations, and KCN and AsO 4 (-) -as metabolic inhibitors.The tissue was brought in contact with different experimental solutions (=medium). The surface corresponding to the outside of the pitchers was cut with a razor blade to remove the cutinized epidermal layer. At this surface the Cl(-) uptake from the medium is a metabolic process which depends on the Cl(-)-concentration of the medium in a manner that corresponds to the MICHAELIS-MENTEN kinetics. The Michaelis-constant of this transport step was 3×10(-2)M. The Cl(-)-efflux into the medium, however, is a passive process.The opposite surface of the tissue slices (corresponding to the inside of the pitchers) carries the glands. The chloride secretion taking place here is also dependent on metabolism. In vitro it occurs even when a high gradient of chloride concentration has been set up between the medium and the solution which is in contact with the glands. In vivo the Cl(-)-concentration of the pitcher fluid and the amount of Cl(-) per gram of tissue water are almost equal.The rôle of chloride in the physiology of Nepenthes is still under investigation, A correlation between the chloride content of the pitcher fluid and its enzymatic activity (Casein-test), however, could already be demonstrated.
Dual activation of CFTR and CLCN2 by lubiprostone in murine nasal epithelia.
Schiffhauer, Eric S; Vij, Neeraj; Kovbasnjuk, Olga; Kang, Po Wei; Walker, Doug; Lee, Seakwoo; Zeitlin, Pamela L
2013-03-01
Multiple sodium and chloride channels on the apical surface of nasal epithelial cells contribute to periciliary fluid homeostasis, a function that is disrupted in patients with cystic fibrosis (CF). Among these channels is the chloride channel CLCN2, which has been studied as a potential alternative chloride efflux pathway in the absence of CFTR. The object of the present study was to use the nasal potential difference test (NPD) to quantify CLCN2 function in an epithelial-directed TetOn CLCN2 transgenic mouse model (TGN-K18rtTA-hCLCN2) by using the putative CLCN2 pharmacological agonist lubiprostone and peptide inhibitor GaTx2. Lubiprostone significantly increased chloride transport in the CLCN2-overexpressing mice following activation of the transgene by doxycycline. This response to lubiprostone was significantly inhibited by GaTx2 after CLCN2 activation in TGN-CLCN2 mice. Cftr(-/-) and Clc2(-/-) mice showed hyperpolarization indicative of chloride efflux in response to lubiprostone, which was fully inhibited by GaTx2 and CFTR inhibitor 172 + GlyH-101, respectively. Our study reveals lubiprostone as a pharmacological activator of both CFTR and CLCN2. Overexpression and activation of CLCN2 leads to improved mouse NPD readings, suggesting it is available as an alternative pathway for epithelial chloride secretion in murine airways. The utilization of CLCN2 as an alternative chloride efflux channel could provide clinical benefit to patients with CF, especially if the pharmacological activator is administered as an aerosol.
DOT National Transportation Integrated Search
2015-06-01
For years, the Kansas Department of Transportation (KDOT) and concrete producers in the state have used a : Rapid Chloride Test for concrete cylinders, AASHTO T277. This test has been thought of as an appropriate quality : control test to evaluate pe...
The catalytic pyrolysis of food waste by microwave heating.
Liu, Haili; Ma, Xiaoqian; Li, Longjun; Hu, ZhiFeng; Guo, Pingsheng; Jiang, Yuhui
2014-08-01
This study describes a series of experiments that tested the use of microwave pyrolysis for treating food waste. Characteristics including rise in temperature, and the three-phase products, were analyzed at different microwave power levels, after adding 5% (mass basis) metal oxides and chloride salts to the food waste. Results indicated that, the metal oxides MgO, Fe₂O₃ and MnO₂ and the chloride salts CuCl₂ and NaCl can lower the yield of bio-oil and enhance the yield of gas. Meanwhile, the metal oxides MgO and MnO₂ can also lower the low heating value (LHV) of solid residues and increase the pH values of the lower layer bio-oils. However, the chloride salts CuCl₂ and NaCl had the opposite effects. The optimal microwave power for treating food waste was 400W; among the tested catalysts, CuCl₂ was the best catalyst and had the largest energy ratio of production to consumption (ERPC), followed by MnO₂. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ibrahim, Ahmed; Ali, Magda M; Abou-Khalil, Nasser S; Ali, Marwa F
2016-03-08
For the last few years, researchers have been interested in developing a method for chemical sterilization which may be a better alternative to surgical castration. An ideal chemical sterilant would be one that effectively arrests spermatogenesis and androgenesis as well as libido with absence of toxic or other side effects. Calcium chloride in various solutions and concentrations has been tested in many animal species, but few studies have been evaluated it in equines as a chemical sterilant. So, the objective of this study was to evaluate the clinical efficacy of chemical castration with 20% calcium chloride dissolved in absolute ethanol in comparison with surgical castration in donkeys based on the changes in the serum testosterone level and the histopathological changes in treated testes. Twelve clinically healthy adult male donkeys were used in this study. Donkeys were divided randomly and equally into two groups: a surgical (S) group (n = 6) and a chemical (C) group (n = 6). Animals in the (S) group were subjected to surgical castration while those in the (C) group received a single bilateral intratesticular injection of 20% calcium chloride dissolved in absolute ethanol (20 ml/testis). Animals were kept under clinical observation for 60 days. Changes in animals' behavior and gross changes in external genitalia were monitored daily. Serum concentrations of testosterone were measured prior to treatment and at 15, 30, 45 and 60 days post-treatment. Testicles in the (C) group were examined histopathologically at the end of the experiment. Chemical castration with intratesticular calcium chloride vs. surgical castration failed to reduce serum concentrations of testosterone throughout the whole duration of the study; however it induced orchitis that was evident by focal necrotic areas in seminiferous tubules, cellular infiltration of neutrophils, proliferative intertubular fibrosis with a compensatory proliferation of Leydig cells. Donkeys tolerated the intratesticular injection of calcium chloride. There were no detectable changes in the general health status of the animals with the exception of swelling in external genitalia, scrotal ulcerations and fistulas. Food and water consumption and the gait of animals remained unaffected. Intratesticular calcium chloride can't be considered an effective method for chemical castration in donkeys.
Pitting Initiation and Propagation of X70 Pipeline Steel Exposed to Chloride-Containing Environments
Yang, Zixuan; Kan, Bo; Li, Jinxu; Su, Yanjing; Qiao, Lijie; Volinsky, Alex A.
2017-01-01
Inclusion-induced pitting initiation mechanisms in X70 steel were investigated by scanning electron microscopy, scanning Kelvin probe force microscopy (SKPFM), immersion and electrochemical polarization tests in chloride-containing ion solutions. There are three inclusion types in the X70 steel. Corrosion test results indicated that pitting corrosion resistance of type A inclusion < type C inclusion < type B inclusion, i.e., (Mn, Ca)S < matrix < (Al, Ca)O. SKPFM test results show that the type A inclusion exhibited both lower and higher potentials than the matrix, while the type B inclusion exhibited higher potential than the matrix. The corrosion test and the SKPFM potential test results are consistent. Potentiodynamic polarization results indicate that the type A and C are active inclusions, while the type B is an inactive inclusion. Three kinds of possible mechanisms of inclusion-induced pitting corrosion are established for the X70 steel. PMID:28902156
Balding, G.O.
1991-01-01
During the past few decades, several municipalities in northeastern Illinois have noted increases in the salinity of water from wells that tap aquifers in rocks of Cambrian and Ordovician age. The municipalities have discontinued the use of, or sealed-off sections of, those wells. The aquifers involved include the Ancell, the Ironton-Galesville, and the Elmhurst-Mt. Simon. To define the location, magnitude, and possible causes for the salinity increases in the six northeastern counties of Illinois, 17 municipal wells and 1 deep test well were selected on the basis of their proximity to major pumping centers, the availability of water-quality data, and their documented maintenance history. Well depths ranged from about 960 to 3,475 feet. One well was finished in the middle confining unit, 2 wells were finished in the Ironton-Galesville aquifer, 4 wells were finished in the Eau Claire confining unit, and 10 wells were finished in the Elmhurst-Mt. Simon aquifer. The deep test well was finished below the Elmhurst-Mt. Simon aquifer in Precambrian-age rock. Chloride concentrations in the municipal wells ranged from less than 5 to greater than 600 milligrams per liter; in the deep test well, they ranged from 13 t o 37,000 milligrams per liter. Some changes in the chloride concentration in water from the studied municipal wells can be related to physical changes to the wells, including the partial filling in of a well, bridging within a well, the cleaning out of a well, or the deepening of a well. Some changes in chloride concentration are not related to physical changes but may be caused by increased pumpage; changes in pumping rate, frequency, or duration; cessation of pumping; improper abandonment of wells; and the upconing of highly mineralized water. The data base was inadequate for a quantitative study of the changes in chloride concentration in water from individual aquifers in rocks of Cambrian and Ordovician age.
Preliminary test results for Li-SOCl2 high-rate D cells
NASA Technical Reports Server (NTRS)
Bragg, Bobby J.; Johnson, Paul
1992-01-01
The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.
Preliminary test results for Li-SOCl2 high-rate D cells
NASA Astrophysics Data System (ADS)
Bragg, Bobby J.; Johnson, Paul
1992-02-01
The performance and abuse characteristics of 55 D-size lithium-thionyl chloride (Li-SOCl2) cells are evaluated at relatively high rates. Results from the following tests are presented: shock test, vibration test, capacity performance, uninsulated short circuit, high temperature exposure, and overdischarge.
A new method of sweat testing: the CF Quantum®sweat test.
Rock, Michael J; Makholm, Linda; Eickhoff, Jens
2014-09-01
Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland-Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97-0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94-100%) and 96% (95% confidence interval: 89-99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%) (p < 0.001). In the post-test questionnaire, 88% of subjects/parents preferred the CFQT test. The CFQT is a fast and simple method of quantitative sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Toxicity of pyrolysis gases from some cellular polymers
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Machado, A. M.
1978-01-01
Various samples of cellular polymers were evaluated for toxicity of pyrolysis gases, using the screening test method developed at the University of San Francisco. The cellular polymer samples included polyimide, polymethacrylimide, polybismaleimide, polyurethane, polyisocyanurate, polyethylene, polychloroprene, polyvinyl chloride, polystyrene, polysiloxane, and polyphosphazene. The cellular polymers exhibited varying levels of toxicity under these test conditions. Among the rigid cellular polymers, times to death were shortest with the imide type foams and longest with polyvinyl chloride and polystyrene. Among the flexible cellular polymers, times to death were shortest with polyimide and polyester, and longest with polychloroprene and polysiloxane. Increased char yield was not necessarily associated with reduced toxicity.
Glinicki, Michał A; Jóźwiak-Niedźwiedzka, Daria; Gibas, Karolina; Dąbrowski, Mariusz
2016-01-02
The objective of this paper is to examine the possible use of new blended cements containing calcareous fly ash in structural concrete, potentially adequate for structural elements of nuclear power plants. The investigation included five new cements made with different contents of non-clinker constituents: calcareous fly ash, siliceous fly ash, ground granulated blastfurnace slag, and a reference cement-ordinary Portland cement. The influence of innovative cements on the resistance of concrete to chloride and carbonation exposure was studied. Additionally, an evaluation of the microstructure was performed using optical microscopy on concrete thin sections. Test results revealed a substantial improvement of the resistance to chloride ion penetration into concrete containing blended cements. The resistance was higher for increased clinker replacement levels and increased with curing time. However, concrete made with blended cements exhibited higher depth of carbonation than the Portland cement concrete, except the Portland-fly ash cement with 14.3% of calcareous fly ash. The thin sections analysis confirmed the values of the carbonation depth obtained from the phenolphthalein test. Test results indicate the possible range of application for new cements containing calcareous fly ash.
Glinicki, Michał A.; Jóźwiak-Niedźwiedzka, Daria; Gibas, Karolina; Dąbrowski, Mariusz
2016-01-01
The objective of this paper is to examine the possible use of new blended cements containing calcareous fly ash in structural concrete, potentially adequate for structural elements of nuclear power plants. The investigation included five new cements made with different contents of non-clinker constituents: calcareous fly ash, siliceous fly ash, ground granulated blastfurnace slag, and a reference cement—ordinary Portland cement. The influence of innovative cements on the resistance of concrete to chloride and carbonation exposure was studied. Additionally, an evaluation of the microstructure was performed using optical microscopy on concrete thin sections. Test results revealed a substantial improvement of the resistance to chloride ion penetration into concrete containing blended cements. The resistance was higher for increased clinker replacement levels and increased with curing time. However, concrete made with blended cements exhibited higher depth of carbonation than the Portland cement concrete, except the Portland-fly ash cement with 14.3% of calcareous fly ash. The thin sections analysis confirmed the values of the carbonation depth obtained from the phenolphthalein test. Test results indicate the possible range of application for new cements containing calcareous fly ash. PMID:28787821
Brain-Compatible Assessments. Second Edition
ERIC Educational Resources Information Center
Ronis, Diane L.
2007-01-01
Diane Ronis, a recognized expert in brain-compatible learning and assessment, goes beyond the world of standardized testing to show educators how to build and use targeted assessments based on the latest neuroscientific research. Updated to reflect recent findings about how the brain learns, this book provides readers with revised tools for…
USDA-ARS?s Scientific Manuscript database
The objectives were to evaluate the efficiency of entomopathogenic fungi against Plutella xylostella (L.) and the compatibility of the most virulent isolates with some of the insecticides registered for use on cabbage crops. Pathogenicity tests used isolates of Beauveria bassiana, Metarhizium rileyi...
McCluskey, Susan V; Sztajnkrycer, Matthew D; Jenkins, Donald A; Zietlow, Scott P; Berns, Kathleen S; Park, Myung S
2014-01-01
Tranexamic acid has recently been demonstrated to decrease all-cause mortality and deaths due to hemorrhage in trauma patients. The optimal administration of tranexamic acid is within one hour of injury, but not more than three hours from the time of injury. To aid with timely administration, a premixed solution of 1 gram tranexamic acid and 0.9% sodium chloride was proposed to be stocked as a medication in both the aeromedical transport helicopters and Emergency Department at Mayo Clinic Hospital--Rochester Saint Marys Campus. Since no published stability data exists for tranexamic acid diluted with 0.9% sodium chloride, this study was undertaken to determine the stability of tranexamic acid diluted with 0.9% sodium chloride while being stored in two types of containers. Stability was determined through the use of a stability-indicating high-performance liquid reverse phase chromatography assay, pH, and visual tests. Tranexamic acid solutions of 1 gram in 0.9% sodium chloride 65 mL were studied at predetermined intervals for 90 days in ethylene/propylene copolymer plastic containers, protected from light, and at both controlled room and refrigerated temperatures. Tranexamic acid solutions of 1 gram in 0.9% sodium chloride 50 mL were studied at predetermined intervals for 180 days in clear Type 1 borosilicate glass vials sealed with intact elastomeric, Flourotec-coated stoppers, stored protected from light at controlled room temperature. Solutions stored in the ethylene/propylene copolymer plastic containers at both storage temperatures maintained at least 98% of initial potency throughout the 90-day study period. Solutions stored in glass vials at controlled room temperature maintained at least 92% of initial potency throughout the 180-day study period. Visual and pH tests revealed stable, clear, colorless, and particulate-free solutions throughout the respective study periods.
Efficacy of Two Novel Anodic Coatings for Enhanced Corrosion Protection of Aluminum Armor Alloys
2014-01-01
nitrate solution of a given metal electrolytically impregnating the porous oxide with the desired metal (5)—for example, silicon (Si) and silver (Ag...performed using the same equipment and data acquisition program previously described. Cells were filled with a 3.5% sodium chloride solution and the...electrochemical impedance spectroscopy h hour HATE Hydraulic Adhesion Test Equipment in inch NaCl sodium chloride OCP open circuit potential OSD
2012-01-01
Background Magnetic resonance imaging (MRI) is an important tool for cardiac research, and it is frequently used for resting cardiac assessments. However, research into non-pharmacological stress cardiac evaluation is limited. Methods We aimed to design a portable and relatively inexpensive MRI cycle ergometer capable of continuously measuring pedalling workload while patients exercise to maintain target heart rates. Results We constructed and tested an MRI-compatible cycle ergometer for a 1.5 T MRI scanner. Resting and sub-maximal exercise images (at 110 beats per minute) were successfully obtained in 8 healthy adults. Conclusions The MRI-compatible cycle ergometer constructed by our research group enabled cardiac assessments at fixed heart rates, while continuously recording power output by directly measuring pedal force and crank rotation. PMID:22423637
NASA Technical Reports Server (NTRS)
Valdez, A.
1999-01-01
This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Electromagnetic Interference (EMI), Electromagnetic Susceptibility, and Electromagnetic Compatibility (EMC) qualification test for the Meteorological Satellite (METSAT) and the Meteorological Operation Platform (METOP) projects. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/5D. This document describes the EMI/EMC test performed by Aerojet and it is presented in the following manner: Section-1 contains introductory material and a brief summary of the test results. Section 2 contains more detailed descriptions of the test plan, test procedure, and test results for each type of EMI/EMC test conducted. Section 3 contains supplementary information that includes test data sheets, plots, and calculations collected during the qualification testing.
40 CFR 62.15230 - What types of stack tests must I conduct?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 8 2010-07-01 2010-07-01 false What types of stack tests must I... August 30, 1999 Stack Testing § 62.15230 What types of stack tests must I conduct? Conduct initial and... matter, opacity, hydrogen chloride, and fugitive ash. ...
40 CFR 62.15230 - What types of stack tests must I conduct?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 8 2011-07-01 2011-07-01 false What types of stack tests must I... August 30, 1999 Stack Testing § 62.15230 What types of stack tests must I conduct? Conduct initial and... matter, opacity, hydrogen chloride, and fugitive ash. ...
Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan
2015-01-01
Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582
DOT National Transportation Integrated Search
2015-06-01
For years, the Kansas Department of Transportation (KDOT) and concrete producers in : the state have used a Rapid Chloride Test for concrete cylinders, AASHTO T277. This : test has been thought of as an appropriate quality control test to evaluate pe...
Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.
Aralica, Merica; Krleza, Jasna Lenicek
2017-02-15
Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.
Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia
Aralica, Merica; Krleza, Jasna Lenicek
2017-01-01
Introduction Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. Materials and methods EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Results Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Conclusion Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level. PMID:28392735
Apollo-Soyuz test project docking system
NASA Technical Reports Server (NTRS)
Swan, W. L., Jr.
1976-01-01
The United States and Soviet Union in July 1975 successfully completed a joint space mission utilizing each country's spacecraft and the compatible docking system designed and fabricated by each country. The compatible docking system is described, along with the extensive research, development, and testing leading up to the successful mission. It also describes the formulation and implementation of methods for breaking the language barrier, bridging the extensive distances for communication and travel, and adjusting to each country's different culture during the three-year development program.
NASA Technical Reports Server (NTRS)
Faget, N. M.
1986-01-01
Attention is given to results obtained to date in developmental investigations of a thermal energy storage (TES) system for the projected NASA Space Station's solar dynamic power system; these tests have concentrated on issues related to materials compatibility for phase change materials (PCMs) and their containment vessels' materials. The five PCMs tested have melting temperatures that correspond to the operating temperatures of either the Brayton or Rankine heat engines, which were independently chosen for their high energy densities.
NASA Astrophysics Data System (ADS)
Yang, Dongrui
Corrosion inhibitors as effective anti-corrosion applications were widely studied and drawn much attention in both academe and industrial area. In this work, a systematic work, including inhibitors selection, anti-corrosion property and characterization, influence on scale formation, testing system design and so on, were reported. The corrosion inhibition performance of four imidazolium ionic liquids in carbon dioxide saturated NaCl solution was investigated by using electrochemical and surface analysis technologies. The four compounds are 1-ethyl-3-methylimidazolium chloride (a), 1-butyl-3-methylimidazolium chloride (b), 1-hexyl-3-methylimidazolium chloride (c), 1-decyl-3-methylimidazolium chloride (d). Under the testing conditions, compound d showed the highest inhibition efficiency and selected as the main object of further study. As a selected representative formula, 1-decyl-3-methylimidazolium chloride was studied in detail about its corrosion inhibition performance on mild steel in carbon dioxide saturated NaCl brine at pH 3.8 and 6.8. Electrochemical and surface analysis techniques were used to characterize the specimen corrosion process during the immersion in the blank and inhibiting solutions. The precorrosion of specimen surface showed significant and different influences on the anti-corrosion property of DMICL at pH 3.8 and 6.8. The corrosion inhibition efficiency (IE) was calculated based on parameters obtained from electrochemical techniques; the achieved IE was higher than 98% at the 25th hour for the steel with a well-polished surface at pH 3.8. The fitting parameters obtained from electrochemical data helped to account for the interfacial changes. As proved in previous research, 1-decyl-3-methylimidazolium chloride could be used as good corrosion inhibitors under certain conditions. However, under other conditions, such chemicals, as well as other species in oil transporting system, could be a factor influencing the evolution of protective surface inorganic layer. In this part, the FeCO3 layer evolution process for API 5L X52 carbon steel in CO2-saturated NaCl brine in the absence and in the presence of 1-decyl-3-methylimidazolium chloride ionic liquid was characterized using electrochemical techniques. Two models were developed to account for the interfacial evolution: the first model considered the balance of positive and negative charges at the interface of the metal and electrolyte in blank solution, while the second one considered the layer coverage and evolution with the imidazolium compound. The corrosion testing system is scientifically and practically critical for corrosion testing and simulations. In this part, a flowing fluid loop cell (FFLC) system was constructed to simulate the corrosion environment in the pipeline. Main content of this work include the construction of the flowing fluid cell loop (FFLC) system, as well as FFLC-based corrosion/anticorrosion tests under simulated acid conditions. Electrochemical Impedance Spectroscopy (EIS) and Linear Polarization Resistance (LPR) were used as prime techniques to quantify and characterize the corrosion behaviors of carbon steel specimen. The Eff vs. Reynolds number (Re) plots for the specimen located in the chamber and in the loop branch were provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drummond, R.A.; Olson, G.F.; Battermna, A.R.
1974-01-01
The lowest concentration of methylmercuric chloride (MMC) and mercuric chloride added to Lake Superior water that caused a significant increase in cough frequency in Brook trout was 3 micrograms Hg/liter. Cough frequency is a good short-term indicator of the long-term effects of MMC. The response can be used to predict the safe concentration of mercuric chloride since the long-term effects of the compound are not known. Increases in cough frequency were proportional to the concentration (from 3 to 12 micrograms Hg/liter) of both compounds at pH 7.5. The fish were more responsive to MMC when the pH of the testmore » water was lowered to 6.0; response to mercuric chloride was not changed by lowered pH. Fish exposed to MMC at pH 6.0 contained more total mercury in their gills and red blood cells than fish tested at pH 9.0. The uptake of mercury by brook trout exposed to mercuric chloride did not differ significantly at pH 6.0 and 9.0.« less
Allan, A M; Harris, R A
1989-06-01
Several findings suggest that barbiturates and alcohol produce their sedative effects through a common neural and possibly a common genetic mechanism. We tested this hypothesis by examining the correlation between ethanol and pentobarbital sedative effects in individual animals from a genetically heterogeneous population. The duration of pentobarbital-induced hypnosis (sleep-time) was unrelated to the sleep-time produced by ethanol in heterogeneous stock (HS) mice. Therefore, the present study also examined the effect of ethanol, pentobarbital, and flunitrazepam on muscimol-stimulated chloride flux into brain membranes prepared from HS mice selected for differences in pentobarbital- and ethanol-induced sleep-time. Brain membranes from mice selected for differences in ethanol sleep-time were differentially responsive to ethanol- and flunitrazepam-, but not to pentobarbital-induced augmentation of muscimol-stimulated chloride flux. No differences in augmentation of chloride flux by ethanol, pentobarbital, or flunitrazepam were found in membranes prepared from mice differentially sensitive to pentobarbital hypnosis. The ability of muscimol to stimulate chloride uptake was not related to ethanol or pentobarbital sensitivity. These findings suggest that sensitivity to ethanol is not likely to be genetically linked to pentobarbital sensitivity.
Buccigrossi, Vittoria; Laudiero, Gabriella; Russo, Carla; Miele, Erasmo; Sofia, Morena; Monini, Marina; Ruggeri, Franco Maria; Guarino, Alfredo
2014-01-01
Rotavirus (RV) infection causes watery diarrhea via multiple mechanisms, primarily chloride secretion in intestinal epithelial cell. The chloride secretion largely depends on non-structural protein 4 (NSP4) enterotoxic activity in human enterocytes through mechanisms that have not been defined. Redox imbalance is a common event in cells infected by viruses, but the role of oxidative stress in RV infection is unknown. RV SA11 induced chloride secretion in association with an increase in reactive oxygen species (ROS) in Caco-2 cells. The ratio between reduced (GSH) and oxidized (GSSG) glutathione was decreased by RV. The same effects were observed when purified NSP4 was added to Caco-2 cells. N-acetylcysteine (NAC), a potent antioxidant, strongly inhibited the increase in ROS and GSH imbalance. These results suggest a link between oxidative stress and RV-induced diarrhea. Because Saccharomyces boulardii (Sb) has been effectively used to treat RV diarrhea, we tested its effects on RV-infected cells. Sb supernatant prevented RV-induced oxidative stress and strongly inhibited chloride secretion in Caco-2 cells. These results were confirmed in an organ culture model using human intestinal biopsies, demonstrating that chloride secretion induced by RV-NSP4 is oxidative stress-dependent and is inhibited by Sb, which produces soluble metabolites that prevent oxidative stress. The results of this study provide novel insights into RV-induced diarrhea and the efficacy of probiotics.
Guerrero, A; Goñi, S; Allegro, V R
2009-06-15
The durability of class C fly ash belite cement (FABC-2-W) in simulated radioactive liquid waste (SRLW) rich in a mixed sodium chloride and sulphate solution is presented here. The effect of the temperature and potential synergic effect of chloride and sulfate ions are discussed. This study has been carried out according to the Koch-Steinegger test, at the temperature of 20 degrees C and 40 degrees C during a period of 180 days. The durability has been evaluated by the changes of the flexural strength of mortar, fabricated with this cement, immersed in a simulated radioactive liquid waste rich in sulfate (0.5M), chloride (0.5M) and sodium (1.5M) ions--catalogued like severely aggressive for the traditional Portland cement--and demineralised water, which was used as reference. The reaction mechanism of sulphate, chloride and sodium ions with the mortar was evaluated by scanning electron microscopy (SEM), porosity and pore-size distribution, and X-ray diffraction (XRD). The results showed that the chloride binding and formation of Friedel's salt was inhibited by the presence of sulphate. Sulphate ion reacts preferentially with the calcium aluminate hydrates forming non-expansive ettringite which precipitated inside the pores; the microstructure was refined and the mechanical properties enhanced. This process was faster and more marked at 40 degrees C.
Iwano, Megumi; Igarashi, Motoko; Tarutani, Yoshiaki; Kaothien-Nakayama, Pulla; Nakayama, Hideki; Moriyama, Hideki; Yakabe, Ryo; Entani, Tetsuyuki; Shimosato-Asano, Hiroko; Ueki, Masao; Tamiya, Gen; Takayama, Seiji
2014-01-01
In the Brassicaceae, intraspecific non-self pollen (compatible pollen) can germinate and grow into stigmatic papilla cells, while self-pollen or interspecific pollen is rejected at this stage. However, the mechanisms underlying this selective acceptance of compatible pollen remain unclear. Here, using a cell-impermeant calcium indicator, we showed that the compatible pollen coat contains signaling molecules that stimulate Ca2+ export from the papilla cells. Transcriptome analyses of stigmas suggested that autoinhibited Ca2+-ATPase13 (ACA13) was induced after both compatible pollination and compatible pollen coat treatment. A complementation test using a yeast Saccharomyces cerevisiae strain lacking major Ca2+ transport systems suggested that ACA13 indeed functions as an autoinhibited Ca2+ transporter. ACA13 transcription increased in papilla cells and in transmitting tracts after pollination. ACA13 protein localized to the plasma membrane and to vesicles near the Golgi body and accumulated at the pollen tube penetration site after pollination. The stigma of a T-DNA insertion line of ACA13 exhibited reduced Ca2+ export, as well as defects in compatible pollen germination and seed production. These findings suggest that stigmatic ACA13 functions in the export of Ca2+ to the compatible pollen tube, which promotes successful fertilization. PMID:24569769
Proline: Mother Nature;s cryoprotectant applied to protein crystallography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pemberton, Travis A.; Still, Brady R.; Christensen, Emily M.
L-Proline is one of Mother Nature's cryoprotectants. Plants and yeast accumulate proline under freeze-induced stress and the use of proline in the cryopreservation of biological samples is well established. Here, it is shown that L-proline is also a useful cryoprotectant for protein crystallography. Proline was used to prepare crystals of lysozyme, xylose isomerase, histidine acid phosphatase and 1-pyrroline-5-carboxylate dehydrogenase for low-temperature data collection. The crystallization solutions in these test cases included the commonly used precipitants ammonium sulfate, sodium chloride and polyethylene glycol and spanned the pH range 4.6-8.5. Thus, proline is compatible with typical protein-crystallization formulations. The proline concentration neededmore » for cryoprotection of these crystals is in the range 2.0-3.0 M. Complete data sets were collected from the proline-protected crystals. Proline performed as well as traditional cryoprotectants based on the diffraction resolution and data-quality statistics. The structures were refined to assess the binding of proline to these proteins. As observed with traditional cryoprotectants such as glycerol and ethylene glycol, the electron-density maps clearly showed the presence of proline molecules bound to the protein. In two cases, histidine acid phosphatase and 1-pyrroline-5-carboxylate dehydrogenase, proline binds in the active site. It is concluded that L-proline is an effective cryoprotectant for protein crystallography.« less
Proline: Mother Nature’s cryoprotectant applied to protein crystallography
Pemberton, Travis A.; Still, Brady R.; Christensen, Emily M.; Singh, Harkewal; Srivastava, Dhiraj; Tanner, John J.
2012-01-01
l-Proline is one of Mother Nature’s cryoprotectants. Plants and yeast accumulate proline under freeze-induced stress and the use of proline in the cryopreservation of biological samples is well established. Here, it is shown that l-proline is also a useful cryoprotectant for protein crystallography. Proline was used to prepare crystals of lysozyme, xylose isomerase, histidine acid phosphatase and 1-pyrroline-5-carboxylate dehydrogenase for low-temperature data collection. The crystallization solutions in these test cases included the commonly used precipitants ammonium sulfate, sodium chloride and polyethylene glycol and spanned the pH range 4.6–8.5. Thus, proline is compatible with typical protein-crystallization formulations. The proline concentration needed for cryoprotection of these crystals is in the range 2.0–3.0 M. Complete data sets were collected from the proline-protected crystals. Proline performed as well as traditional cryoprotectants based on the diffraction resolution and data-quality statistics. The structures were refined to assess the binding of proline to these proteins. As observed with traditional cryoprotectants such as glycerol and ethylene glycol, the electron-density maps clearly showed the presence of proline molecules bound to the protein. In two cases, histidine acid phosphatase and 1-pyrroline-5-carboxylate dehydrogenase, proline binds in the active site. It is concluded that l-proline is an effective cryoprotectant for protein crystallography. PMID:22868767
Kaiser, Jean-Pierre; Roesslein, Matthias; Diener, Liliane; Wichser, Adrian; Nowack, Bernd; Wick, Peter
2017-01-06
Nanosilver shows great promise for use in industrial, consumer or medical products because of its antimicrobial properties. However, the underlying mechanisms of the effects of silver nanoparticles on human cells are still controversial. Therefore, in the present study the influence of the chloride concentration and different serum content of culture media on the cytotoxic effects of nanosilver was systematically evaluated. Our results show that nanosilver toxicity was strongly affected by the composition of the culture media. The chloride concentration, as well as the carbon content affected the silver agglomeration and the complex formation. But also the dissolution of nanosilver and the availability of free silver ions (Ag + ) were severely affected by the compositions of the culture media. Cells, only exposed to silver particles in suspension and dissolved silver complexes, did not show any effects under all conditions. Nanosilver agglomerates and silver complexes were not very soluble. Thus, cells growing on the bottom of the culture dishes were exposed to sedimented nanosilver agglomerates and precipitated silver complexes. Locally, the concentration of silver on the cell surface was very high, much higher compared the silver concentration in the bulk solution. The cytotoxic effects of nanosilver are therefore a combination of precipitated silver complexes and organic silver compounds rather than free silver ions. Silver coatings are used in health care products due to their bacteriostatic or antibacterial properties. The assessment of the toxicity of a certain compound is mostly done using in vitro assays. Therefore, cytotoxicity studies of nanosilver using human cell cultures have to be undertaken under well controlled and understood cultivations conditions in order to improve the compatibility of different studies. Especially when eukaryotic versus prokaryotic systems are compared for the evaluation of the use of nanosilver as antibacterial coatings for implants in order to prevent bacterial colonization.
A Simplified Extemporaneously Prepared Potassium Chloride Oral Solution.
Tannous, Elias; Tal, Yana; Amarny, Kamal
2016-01-01
Although commercial preparations of oral potassium supplements are usually available, there are times when our Medical Center is faced with situations in which the oral solution of potassium chloride is not available. This solution is necessary for our pediatric outpatients who cannot swallow tablets and need an oral solution. Moreover, there are no studies available which describe an extemporaneously prepared potassium chloride oral solution on which we can rely for assigning a beyond-use date. The aim of this study was to formulate an extemporaneous pediatric oral solution of potassium chloride and to determine the physical and chemical stability of this preparation. We prepared 1 mMoL/mL by withdrawing 25 mL of potassium chloride 14.9%. Ora-Sweet SF was added to 50 mL in a metered flask. The solution was kept refrigerated (2°C to 8°C). Samples were withdrawn to measure potassium concentration, pH, and microbial overgrowth. The test was performed by our biochemical laboratory. The oral solution of potassium chloride 1 mMoL/mL stored at 2°C to 8°C maintained at least 91% of the initial concentration for 28 days. There were no notable changes in pH, and the solution remained physically stable with no visual microbial growth. The oral solution of potassium chloride 1 mMoL/mL prepared in Ora-Sweet and stored at 2°C to 8°C in amber glass bottles is expected to remain stable for 28 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Dual activation of CFTR and CLCN2 by lubiprostone in murine nasal epithelia
Schiffhauer, Eric S.; Vij, Neeraj; Kovbasnjuk, Olga; Kang, Po Wei; Walker, Doug; Lee, Seakwoo
2013-01-01
Multiple sodium and chloride channels on the apical surface of nasal epithelial cells contribute to periciliary fluid homeostasis, a function that is disrupted in patients with cystic fibrosis (CF). Among these channels is the chloride channel CLCN2, which has been studied as a potential alternative chloride efflux pathway in the absence of CFTR. The object of the present study was to use the nasal potential difference test (NPD) to quantify CLCN2 function in an epithelial-directed TetOn CLCN2 transgenic mouse model (TGN-K18rtTA-hCLCN2) by using the putative CLCN2 pharmacological agonist lubiprostone and peptide inhibitor GaTx2. Lubiprostone significantly increased chloride transport in the CLCN2-overexpressing mice following activation of the transgene by doxycycline. This response to lubiprostone was significantly inhibited by GaTx2 after CLCN2 activation in TGN-CLCN2 mice. Cftr−/− and Clc2−/− mice showed hyperpolarization indicative of chloride efflux in response to lubiprostone, which was fully inhibited by GaTx2 and CFTR inhibitor 172 + GlyH-101, respectively. Our study reveals lubiprostone as a pharmacological activator of both CFTR and CLCN2. Overexpression and activation of CLCN2 leads to improved mouse NPD readings, suggesting it is available as an alternative pathway for epithelial chloride secretion in murine airways. The utilization of CLCN2 as an alternative chloride efflux channel could provide clinical benefit to patients with CF, especially if the pharmacological activator is administered as an aerosol. PMID:23316067
In vitro susceptibility of spiroplasmas to heavy-metal salts.
Whitmore, S C; Rissler, J F; Davis, R E
1983-01-01
The susceptibility of six spiroplasma strains to heavy-metal salt was characterized in terms of minimal inhibitory concentrations and minimal biocidal concentrations in broth tube dilution tests. The strains were most susceptible to mercuric chloride and silver nitrate; less susceptible to copper sulfate, cobalt chloride, lead nitrate, and cadmium sulfate; and least susceptible to nickel chloride and zinc sulfate. Spiroplasma citri strains Maroc R8A2 and C189 were the most susceptible to five of eight heavy-metal salts, and honeybee spiroplasma strain AS576 and Spiroplasma floricola strain 23-6 were generally the least susceptible. The difference between the minimal biocidal concentrations and the minimal inhibitory concentrations was greater for certain heavy-metal salts than for others.
Nojavan, Saeed; Ghassempour, Alireza; Bashour, Yosef; Darbandi, Masoud Khalilian; Ahmadi, Seyyed Hamid
2005-01-04
In the present work, the relationship between residual solvents concentration and ampicillin trihydrate crystals stability has been investigated. The amounts of residual solvents determined by GC, X-ray powder diffraction (XRPD) and Fourier transform infrared spectroscopy (FT-IR) were used for characterization of solid state. The obtained results have shown good relationship between concentration of methylene chloride (as a critical residue solvent) and degree of ampicillin trihydrate crystallinity. As with the increasing methylene chloride concentration in the sample the degree of crystallinity decreased after stability test. From this relationship, critical concentration of methylene chloride into the ampicillin trihydrate is obtained and the results can be used for improving the large-scale production of ampicillin trihydrate.
Special features of the technology of boronizing steel in a calcium chloride melt
NASA Astrophysics Data System (ADS)
Chernov, Ya. B.; Anfinogenov, A. I.; Veselov, I. N.
1999-12-01
A technology for hardening machine parts and tools by boronizing in molten calcium chloride with amorphous-boron powder in electrode salt baths has been developed with the aim of creating a closed cycle of utilizing the raw materials and the washing water. A process of boronizing that includes quenching and tempering of the boronized articles is described. The quenching medium is an ecologically safe and readily available aqueous solution of calcium chloride. The process envisages return of the melt components to the boronizing bath. Boronizing by the suggested method was tested for different classes of steel, namely, structural and tool steels for cold and hot deformation. The wear resistance of the boronized steels was studied.
Modeling polyvinyl chloride Plasma Modification by Neural Networks
NASA Astrophysics Data System (ADS)
Wang, Changquan
2018-03-01
Neural networks model were constructed to analyze the connection between dielectric barrier discharge parameters and surface properties of material. The experiment data were generated from polyvinyl chloride plasma modification by using uniform design. Discharge voltage, discharge gas gap and treatment time were as neural network input layer parameters. The measured values of contact angle were as the output layer parameters. A nonlinear mathematical model of the surface modification for polyvinyl chloride was developed based upon the neural networks. The optimum model parameters were obtained by the simulation evaluation and error analysis. The results of the optimal model show that the predicted value is very close to the actual test value. The prediction model obtained here are useful for discharge plasma surface modification analysis.
Bronchial reactions to exposure to welding fumes.
Contreras, G R; Chan-Yeung, M
1997-01-01
OBJECTIVES: To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. METHODS: Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. RESULTS: Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. CONCLUSION: The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation. PMID:9538358
Bronchial reactions to exposure to welding fumes.
Contreras, G R; Chan-Yeung, M
1997-11-01
To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation.