Sample records for chromatic effects contributing

  1. The effects of luminance contribution from large fields to chromatic visual evoked potentials.

    PubMed

    Skiba, Rafal M; Duncan, Chad S; Crognale, Michael A

    2014-02-01

    Though useful from a clinical and practical standpoint uniform, large-field chromatic stimuli are likely to contain luminance contributions from retinal inhomogeneities. Such contribution can significantly influence psychophysical thresholds. However, the degree to which small luminance artifacts influence the chromatic VEP has been debated. In particular, claims have been made that band-pass tuning observed in chromatic VEPs result from luminance intrusion. However, there has been no direct evidence presented to support these claims. Recently, large-field isoluminant stimuli have been developed to control for intrusion from retinal inhomogeneities with particular regard to the influence of macular pigment. We report here the application of an improved version of these full-field stimuli to directly test the influence of luminance intrusion on the temporal tuning of the chromatic VEP. Our results show that band-pass tuning persists even when isoluminance is achieved throughout the extent of the stimulus. In addition, small amounts of luminance intrusion affect neither the shape of the temporal tuning function nor the major components of the VEP. These results support the conclusion that the chromatic VEP can depart substantially from threshold psychophysics with regard to temporal tuning and that obtaining a low-pass function is not requisite evidence of selective chromatic activation in the VEP. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Independence and interaction of luminance and chromatic contributions to spatial hyperacuity performance.

    PubMed

    Cooper, Bonnie; Lee, Barry B

    2014-04-01

    Here we test interactions of luminance and chromatic input to spatial hyperacuity mechanisms. First, we tested alignment of luminance and chromatic gratings matched or mismatched in contrast polarity or grating type. Thresholds with matched gratings were low while all mismatched pairs were elevated. Second, we determined alignment acuity as a function of luminance or chromatic contrast alone or in the presence of constant contrast components of the other type. For in-phase components, performance followed the envelope of the more sensitive mechanism. However, polarity reversals revealed an asymmetric effect for luminance and chromatic conditions, which suggested that luminance can override chromatic mechanisms in hyperacuity; we interpret these findings in the context of spatial mechanisms.

  3. Variation in Extracellular Detoxification Is a Link to Different Carcinogenicity among Chromates in Rodent and Human Lungs.

    PubMed

    Krawic, Casey; Luczak, Michal W; Zhitkovich, Anatoly

    2017-09-18

    Inhalation of soluble chromium(VI) is firmly linked with higher risks of lung cancer in humans. However, comparative studies in rats have found a high lung tumorigenicity for moderately soluble chromates but no tumors for highly soluble chromates. These major species differences remain unexplained. We investigated the impact of extracellular reducers on responses of human and rat lung epithelial cells to different Cr(VI) forms. Extracellular reduction of Cr(VI) is a detoxification process, and rat and human lung lining fluids contain different concentrations of ascorbate and glutathione. We found that reduction of chromate anions in simulated lung fluids was principally driven by ascorbate with only minimal contribution from glutathione. The addition of 500 μM ascorbate (∼rat lung fluid concentration) to culture media strongly inhibited cellular uptake of chromate anions and completely prevented their cytotoxicity even at otherwise lethal doses. While proportionally less effective, 50 μM extracellular ascorbate (∼human lung fluid concentration) also decreased uptake of chromate anions and their cytotoxicity. In comparison to chromate anions, uptake and cytotoxicity of respirable particles of moderately soluble CaCrO 4 and SrCrO 4 were much less sensitive to suppression by extracellular ascorbate, especially during early exposure times and in primary bronchial cells. In the absence of extracellular ascorbate, chromate anions and CaCrO 4 /SrCrO 4 particles produced overall similar levels of DNA double-stranded breaks, with less soluble particles exhibiting a slower rate of breakage. Our results indicate that a gradual extracellular dissolution and a rapid internalization of calcium chromate and strontium chromate particles makes them resistant to detoxification outside the cells, which is extremely effective for chromate anions in the rat lung fluid. The detoxification potential of the human lung fluid is significant but much lower and insufficient to provide a threshold-type dose dependence for soluble chromates.

  4. Stereoscopic depth perception varies with hues

    NASA Astrophysics Data System (ADS)

    Chen, Zaiqing; Shi, Junsheng; Tai, Yonghang; Yun, Lijun

    2012-09-01

    The contribution of color information to stereopsis is controversial, and whether the stereoscopic depth perception varies with chromaticity is ambiguous. This study examined the changes in depth perception caused by hue variations. Based on the fact that a greater disparity range indicates more efficient stereoscopic perception, the effect of hue variations on depth perception was evaluated through the disparity range with random-dot stereogram stimuli. The disparity range was obtained by constant-stimulus method for eight chromaticity points sampled from the CIE 1931 chromaticity diagram. Eight sample points include four main color hues: red, yellow, green, and blue at two levels of chroma. The results show that the disparity range for the yellow hue is greater than the red hue, the latter being greater than the blue hue and the disparity range for green hue is smallest. We conclude that the perceived depth is not the same for different hues for a given size of disparity. We suggest that the stereoscopic depth perception can vary with chromaticity.

  5. Does the chromatic Mach bands effect exist?

    PubMed

    Tsofe, Avital; Spitzer, Hedva; Einav, Shmuel

    2009-06-30

    The achromatic Mach bands effect is a well-known visual illusion, discovered over a hundred years ago. This effect has been investigated thoroughly, mainly for its brightness aspect. The existence of Chromatic Mach bands, however, has been disputed. In recent years it has been reported that Chromatic Mach bands are not perceived under controlled iso-luminance conditions. However, here we show that a variety of Chromatic Mach bands, consisting of chromatic and achromatic regions, separated by a saturation ramp, can be clearly perceived under iso-luminance and iso-brightness conditions. In this study, observers' eye movements were recorded under iso-brightness conditions. Several observers were tested for their ability to perceive the Chromatic Mach bands effect and its magnitude, across different cardinal and non-cardinal Chromatic Mach bands stimuli. A computational model of color adaptation, which predicted color induction and color constancy, successfully predicts this variation of Chromatic Mach bands. This has been tested by measuring the distance of the data points from the "achromatic point" and by calculating the shift of the data points from predicted complementary lines. The results suggest that the Chromatic Mach bands effect is a specific chromatic induction effect.

  6. Chromatic assimilation unaffected by perceived depth of inducing light.

    PubMed

    Shevell, Steven K; Cao, Dingcai

    2004-01-01

    Chromatic assimilation is a shift toward the color of nearby light. Several studies conclude that a neural process contributes to assimilation but the neural locus remains in question. Some studies posit a peripheral process, such as retinal receptive-field organization, while others claim the neural mechanism follows depth perception, figure/ground segregation, or perceptual grouping. The experiments here tested whether assimilation depends on a neural process that follows stereoscopic depth perception. By introducing binocular disparity, the test field judged in color was made to appear in a different depth plane than the light that induced assimilation. The chromaticity and spatial frequency of the inducing light, and the chromaticity of the test light, were varied. Chromatic assimilation was found with all inducing-light sizes and chromaticities, but the magnitude of assimilation did not depend on the perceived relative depth planes of the test and inducing fields. We found no evidence to support the view that chromatic assimilation depends on a neural process that follows binocular combination of the two eyes' signals.

  7. LUNG INJURY, INFLAMMATION AND AKT SIGNALING FOLLOWING INHALATION OF PARTICULATE HEXAVALENT CHROMIUM

    PubMed Central

    Beaver, Laura M.; Stemmy, Erik J.; Constant, Stephanie L.; Schwartz, Arnold; Little, Laura G.; Gigley, Jason P.; Chun, Gina; Sugden, Kent D.; Ceryak, Susan M.; Patierno, Steven R.

    2013-01-01

    Certain particulate hexavalent chromium [Cr(VI)] compounds are human respiratory carcinogens that release genotoxic soluble chromate, and are associated with fibrosis, fibrosarcomas, adenocarcinomas and squamous cell carcinomas of the lung. We postulate that inflammatory processes and mediators may contribute to the etiology of Cr(VI) carcinogenesis, however the immediate (0–24 hours) pathologic injury and immune responses after exposure to particulate chromates have not been adequately investigated. Our aim was to determine the nature of the lung injury, inflammatory response, and survival signaling responses following intranasal exposure of BALB/c mice to particulate basic zinc chromate. Factors associated with lung injury, inflammation and survival signaling were measured in airway lavage fluid and in lung tissue. A single chromate exposure induced an acute immune response in the lung, characterized by a rapid and significant increase in IL-6 and GRO-α levels, an influx of neutrophils, and a decline in macrophages in lung airways. Histological examination of lung tissue in animals challenged with a single chromate exposure revealed an increase in bronchiolar cell apoptosis and mucosal injury. Furthermore, chromate exposure induced injury and inflammation that progressed to alveolar and interstitial pneumonitis. Finally, a single Cr(VI) challenge resulted in a rapid and persistent increase in the number of airways immunoreactive for phosphorylation of the survival signaling protein Akt, on serine 473. These data illustrate that chromate induces both survival signaling and an inflammatory response in the lung, which we postulate may contribute to early oncogenesis. PMID:19109987

  8. Thick lens chromatic effective focal length variation versus bending

    NASA Astrophysics Data System (ADS)

    Sparrold, Scott

    2017-11-01

    Longitudinal chromatic aberration (LCA) can limit the optical performance in refractive optical systems. Understanding a singlet's chromatic change of effective focal leads to insights and methods to control LCA. Long established, first order theory, shows the chromatic change in focal length for a zero thickness lens is proportional to it's focal length divided by the lens V number or inverse dispersion. This work presents the derivation of an equation for a thick singlet's chromatic change in effective focal length as a function of center thickness, t, dispersion, V, index of refraction, n, and the Coddington shape factor, K. A plot of bending versus chromatic focal length variation is presented. Lens thickness does not influence chromatic variation of effective focal length for a convex plano or plano convex lens. A lens's center thickness'influence on chromatic focal length variation is more pronounced for lower indices of refraction.

  9. Chromatic induction in space and time.

    PubMed

    Coia, Andrew J; Shevell, Steven K

    2018-04-01

    The color appearance of a light depends on variation in the complete visual field over both space and time. In the spatial domain, a chromatic stimulus within a patterned chromatic surround can appear a different hue than the same stimulus within a uniform surround. In the temporal domain, a stimulus presented as an element of a continuously changing chromaticity can appear a different color compared to the identical stimulus, presented simultaneously but viewed alone. This is the flash-lag effect for color, which has an analog in the domain of motion: a pulsed object seen alone can appear to lag behind an identical pulsed object that is an element of a motion sequence. Studies of the flash-lag effect for motion have considered whether it is mediated by a neural representation for the moving physical stimulus or, alternatively, for the perceived motion. The current study addresses this question for the flash-lag effect for color by testing whether the color flash lag depends on a representation of only the changing chromatic stimulus or, alternatively, its color percept, which can be altered by chromatic induction. baseline measurements for spatial chromatic induction determined the chromaticity of a flashed ring within a uniform surround that matched a flashed ring within a patterned surround. Baseline measurements for the color flash-lag effect determined the chromaticity of a pulsed ring presented alone (within a uniform surround) that matched a pulsed ring presented in a sequence of changing chromaticity over time (also within a uniform surround). Finally, the main experiments combined chromatic induction from a patterned surround and the flash-lag effect, in three conditions: (1) both the changing and pulsed rings were within a patterned chromatic surround; (2) the changing ring was within a patterned surround and the pulsed ring within a uniform surround; and (3) the changing ring was within a uniform surround and the pulsed ring within a patterned surround. the flash-lag measurements for a changing chromaticity were affected by perceptual changes induced by the surrounding chromatic pattern. Thus, the color shifts induced by a chromatic surround are incorporated in the neural representation mediating the flash-lag effect for color.

  10. Stimulus size dependence of hue changes induced by chromatic surrounds.

    PubMed

    Kellner, Christian Johannes; Wachtler, Thomas

    2016-03-01

    A chromatic surround induces a change in the perceived hue of a stimulus. This shift in hue depends on the chromatic difference between the stimulus and the surround. We investigated how chromatic induction varies with stimulus size and whether the size dependence depends on the surround hue. Subjects performed asymmetric matching of color stimuli with different sizes in surrounds of different chromaticities. Generally, induced hue shifts decreased with increasing stimulus size. This decrease was quantitatively different for different surround hues. However, when size effects were normalized to an overall induction strength, the chromatic specificity was largely reduced. The separability of inducer chromaticity and stimulus size suggests that these effects are mediated by different neural mechanisms.

  11. Neuronal Mechanism for Compensation of Longitudinal Chromatic Aberration-Derived Algorithm.

    PubMed

    Barkan, Yuval; Spitzer, Hedva

    2018-01-01

    The human visual system faces many challenges, among them the need to overcome the imperfections of its optics, which degrade the retinal image. One of the most dominant limitations is longitudinal chromatic aberration (LCA), which causes short wavelengths (blue light) to be focused in front of the retina with consequent blurring of the retinal chromatic image. The perceived visual appearance, however, does not display such chromatic distortions. The intriguing question, therefore, is how the perceived visual appearance of a sharp and clear chromatic image is achieved despite the imperfections of the ocular optics. To address this issue, we propose a neural mechanism and computational model, based on the unique properties of the S -cone pathway. The model suggests that the visual system overcomes LCA through two known properties of the S channel: (1) omitting the contribution of the S channel from the high-spatial resolution pathway (utilizing only the L and M channels). (b) Having large and coextensive receptive fields that correspond to the small bistratified cells. Here, we use computational simulations of our model on real images to show how integrating these two basic principles can provide a significant compensation for LCA. Further support for the proposed neuronal mechanism is given by the ability of the model to predict an enigmatic visual phenomenon of large color shifts as part of the assimilation effect.

  12. Neuronal Mechanism for Compensation of Longitudinal Chromatic Aberration-Derived Algorithm

    PubMed Central

    Barkan, Yuval; Spitzer, Hedva

    2018-01-01

    The human visual system faces many challenges, among them the need to overcome the imperfections of its optics, which degrade the retinal image. One of the most dominant limitations is longitudinal chromatic aberration (LCA), which causes short wavelengths (blue light) to be focused in front of the retina with consequent blurring of the retinal chromatic image. The perceived visual appearance, however, does not display such chromatic distortions. The intriguing question, therefore, is how the perceived visual appearance of a sharp and clear chromatic image is achieved despite the imperfections of the ocular optics. To address this issue, we propose a neural mechanism and computational model, based on the unique properties of the S-cone pathway. The model suggests that the visual system overcomes LCA through two known properties of the S channel: (1) omitting the contribution of the S channel from the high-spatial resolution pathway (utilizing only the L and M channels). (b) Having large and coextensive receptive fields that correspond to the small bistratified cells. Here, we use computational simulations of our model on real images to show how integrating these two basic principles can provide a significant compensation for LCA. Further support for the proposed neuronal mechanism is given by the ability of the model to predict an enigmatic visual phenomenon of large color shifts as part of the assimilation effect. PMID:29527525

  13. Chromatic Titanium Photoanode for Dye-Sensitized Solar Cells under Rear Illumination.

    PubMed

    Huang, Chih-Hsiang; Chen, Yu-Wen; Chen, Chih-Ming

    2018-01-24

    Titanium (Ti) has high potential in many practical applications such as biomedicine, architecture, aviation, and energy. In this study, we demonstrate an innovative application of dye-sensitized solar cells (DSSCs) based on Ti photoanodes that can be integrated into the roof engineering of large-scale architectures. A chromatic Ti foil produced by anodizing oxidation (coloring) technology is an attractive roof material for large-scale architecture, showing a colorful appearance due to the formation of a reflective TiO 2 thin layer on both surfaces of Ti. The DSSC is fabricated on the backside of the chromatic Ti foil using the Ti foil as the working electrode, and this roof-DSSC hybrid configuration can be designed as an energy harvesting device for indoor artificial lighting. Our results show that the facet-textured TiO 2 layer on the chromatic Ti foil not only improves the optical reflectance for better light utilization but also effectively suppresses the charge recombination for better electron collection. The power conversion efficiency of the roof-DSSC hybrid system is improved by 30-40% with a main contribution from an improvement of short-circuit current density under standard 1 sun and dim-light (600-1000 lx) illumination.

  14. Chromatic discrimination: differential contributions from two adapting fields

    PubMed Central

    Cao, Dingcai; Lu, Yolanda H.

    2012-01-01

    To test whether a retinal or cortical mechanism sums contributions from two adapting fields to chromatic discrimination, L/M discrimination was measured with a test annulus surrounded by an inner circular field and an outer rectangular field. A retinal summation mechanism predicted that the discrimination pattern would not change with a change in the fixation location. Therefore, the fixation was set either in the inner or the outer field in two experiments. When one of the adapting fields was “red” and the other was “green,” the adapting field where the observer fixated always had a stronger influence on chromatic discrimination. However, when one adapting field was “white” and the other was red or green, the white field always weighted more heavily than the other adapting field in determining discrimination thresholds, whether the white field or the fixation was in the inner or outer adapting field. These results suggest that a cortical mechanism determines the relative contributions from different adapting fields. PMID:22330364

  15. Chromatic discrimination: differential contributions from two adapting fields.

    PubMed

    Cao, Dingcai; Lu, Yolanda H

    2012-02-01

    To test whether a retinal or cortical mechanism sums contributions from two adapting fields to chromatic discrimination, L/M discrimination was measured with a test annulus surrounded by an inner circular field and an outer rectangular field. A retinal summation mechanism predicted that the discrimination pattern would not change with a change in the fixation location. Therefore, the fixation was set either in the inner or the outer field in two experiments. When one of the adapting fields was "red" and the other was "green," the adapting field where the observer fixated always had a stronger influence on chromatic discrimination. However, when one adapting field was "white" and the other was red or green, the white field always weighted more heavily than the other adapting field in determining discrimination thresholds, whether the white field or the fixation was in the inner or outer adapting field. These results suggest that a cortical mechanism determines the relative contributions from different adapting fields. © 2012 Optical Society of America

  16. Replacement of chromates in paints and corrosion protection systems [Stage 1

    DOT National Transportation Integrated Search

    2004-05-01

    This technical report presents the first stage results of a multi-year project to develop chromate-free paints and corrosion protection systems. Chromate coatings and chromate-containing paints are very effective in providing corrosion resistance and...

  17. Luminance and chromatic contributions to a hyperacuity task: isolation by contrast polarity and target separation

    PubMed Central

    Sun, Hao; Cooper, Bonnie; Lee, Barry B.

    2012-01-01

    Vernier thresholds are known to be elevated when a target pair has opposite contrast polarity. Polarity reversal is used to assess the role of luminance and chromatic pathways in hyperacuity performance. Psychophysical hyperacuity thresholds were measured for pairs of gratings of various combinations of luminance (Lum) and chromatic (Chr) contrast polarities, at different ratios of luminance to chromatic contrast. With two red-green gratings of matched luminance and chromatic polarity (+Lum+Chr), there was an elevation of threshold at isoluminance. When both luminance and chromatic polarity were mismatched (−Lum−Chr), thresholds were substantially elevated under all conditions. With the same luminance contrast polarity and opposite chromatic polarity (+Lum−Chr) thresholds were only elevated close to isoluminance; in the reverse condition (−Lum+Chr), thresholds were elevated as in the −Lum−Chr condition except close to equiluminance. Similar data were obtained for gratings isolating the short-wavelength cone mechanism. Further psychophysical measurements assessed the role of target separation with matched or mismatched contrast polarity; similar results were found for luminance and chromatic gratings. Comparison physiological data were collected from parafoveal ganglion cells of the macaque retina. Positional precision of ganglion cell signals was assessed under conditions related to the psychophysical measurements. On the basis of these combined observations, it is argued that both magnocellular, parvocellular, and koniocellular pathways have access to cortical positional mechanisms associated with vernier acuity. PMID:22306680

  18. Photographic simulation of off-axis blurring due to chromatic aberration in spectacle lenses.

    PubMed

    Doroslovački, Pavle; Guyton, David L

    2015-02-01

    Spectacle lens materials of high refractive index (nd) tend to have high chromatic dispersion (low Abbé number [V]), which may contribute to visual blurring with oblique viewing. A patient who noted off-axis blurring with new high-refractive-index spectacle lenses prompted us to do a photographic simulation of the off-axis aberrations in 3 readily available spectacle lens materials, CR-39 (nd = 1.50), polyurethane (nd = 1.60), and polycarbonate (nd = 1.59). Both chromatic and monochromatic aberrations were found to cause off-axis image degradation. Chromatic aberration was more prominent in the higher-index materials (especially polycarbonate), whereas the lower-index CR-39 had more astigmatism of oblique incidence. It is important to consider off-axis aberrations when a patient complains of otherwise unexplained blurred vision with a new pair of spectacle lenses, especially given the increasing promotion of high-refractive-index materials with high chromatic dispersion. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  19. The influence of chromatic context on binocular color rivalry: Perception and neural representation

    PubMed Central

    Hong, Sang Wook; Shevell, Steven K.

    2008-01-01

    The predominance of rivalrous targets is affected by surrounding context when stimuli rival in orientation, motion or color. This study investigated the influence of chromatic context on binocular color rivalry. The predominance of rivalrous chromatic targets was measured in various surrounding contexts. The first experiment showed that a chromatic surround's influence was stronger when the surround was uniform or a grating with luminance contrast (chromatic/black grating) compared to an equiluminant grating (chromatic/white). The second experiment revealed virtually no effect of the orientation of the surrounding chromatic context, using chromatically rivalrous vertical gratings. These results are consistent with a chromatic representation of the context by a non-oriented, chromatically selective and spatially antagonistic receptive field. Neither a double-opponent receptive field nor a receptive field without spatial antagonism accounts for the influence of context on binocular color rivalry. PMID:18331750

  20. Luminance and chromatic contributions to a hyperacuity task: isolation by contrast polarity and target separation.

    PubMed

    Sun, Hao; Cooper, Bonnie; Lee, Barry B

    2012-03-01

    Vernier thresholds are known to be elevated when a target pair has opposite contrast polarity. Polarity reversal is used to assess the role of luminance and chromatic pathways in hyperacuity performance. Psychophysical hyperacuity thresholds were measured for pairs of gratings of various combinations of luminance (Lum) and chromatic (Chr) contrast polarities, at different ratios of luminance to chromatic contrast. With two red-green gratings of matched luminance and chromatic polarity (+Lum+Chr), there was an elevation of threshold at isoluminance. When both luminance and chromatic polarity were mismatched (-Lum-Chr), thresholds were substantially elevated under all conditions. With the same luminance contrast polarity and opposite chromatic polarity (+Lum-Chr) thresholds were only elevated close to isoluminance; in the reverse condition (-Lum+Chr), thresholds were elevated as in the -Lum-Chr condition except close to equiluminance. Similar data were obtained for gratings isolating the short-wavelength cone mechanism. Further psychophysical measurements assessed the role of target separation with matched or mismatched contrast polarity; similar results were found for luminance and chromatic gratings. Comparison physiological data were collected from parafoveal ganglion cells of the macaque retina. Positional precision of ganglion cell signals was assessed under conditions related to the psychophysical measurements. On the basis of these combined observations, it is argued that both magnocellular, parvocellular, and koniocellular pathways have access to cortical positional mechanisms associated with vernier acuity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Effect of Chromate and Chromate-Free Organic Coatings on Corrosion Fatigue of an Aluminum Alloy

    DTIC Science & Technology

    2012-02-20

    Investigations of alloy AA7075 corrosion in acid rain solution, inhibited by chromate-free blends of zinc phosphate with bentonite, zeolite and calcium...with solution components. Single use of zinc phosphate and these ion exchanged pigments for corrosion inhibition do not provide desired effect...primer performance against corrosion fatigue cracking under a commercial polyurethane topcoat. As a control , they used samples of chromated AA2024

  2. The effect of chromatic and luminance information on reaction times.

    PubMed

    O'Donell, Beatriz M; Barraza, Jose F; Colombo, Elisa M

    2010-07-01

    We present a series of experiments exploring the effect of chromaticity on reaction time (RT) for a variety of stimulus conditions, including chromatic and luminance contrast, luminance, and size. The chromaticity of these stimuli was varied along a series of vectors in color space that included the two chromatic-opponent-cone axes, a red-green (L-M) axis and a blue-yellow [S - (L + M)] axis, and intermediate noncardinal orientations, as well as the luminance axis (L + M). For Weber luminance contrasts above 10-20%, RTs tend to the same asymptote, irrespective of chromatic direction. At lower luminance contrast, the addition of chromatic information shortens the RT. RTs are strongly influenced by stimulus size when the chromatic stimulus is modulated along the [S - (L + M)] pathway and by stimulus size and adaptation luminance for the (L-M) pathway. RTs are independent of stimulus size for stimuli larger than 0.5 deg. Data are modeled with a modified version of Pieron's formula with an exponent close to 2, in which the stimulus intensity term is replaced by a factor that considers the relative effects of chromatic and achromatic information, as indexed by the RMS (square-root of the cone contrast) value at isoluminance and the Weber luminance contrast, respectively. The parameters of the model reveal how RT is linked to stimulus size, chromatic channels, and adaptation luminance and how they can be interpreted in terms of two chromatic mechanisms. This equation predicts that, for isoluminance, RTs for a stimulus lying on the S-cone pathway are higher than those for a stimulus lying on the L-M-cone pathway, for a given RMS cone contrast. The equation also predicts an asymptotic trend to the RT for an achromatic stimulus when the luminance contrast is sufficiently large.

  3. Ocular Chromatic Aberrations and Their Effects on Polychromatic Retinal Image Quality

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoxiao

    Previous studies of ocular chromatic aberrations have concentrated on chromatic difference of focus (CDF). Less is known about the chromatic difference of image position (CDP) in the peripheral retina and no experimental attempt has been made to measure the ocular chromatic difference of magnification (CDM). Consequently, theoretical modelling of human eyes is incomplete. The insufficient knowledge of ocular chromatic aberrations is partially responsible for two unsolved applied vision problems: (1) how to improve vision by correcting ocular chromatic aberration? (2) what is the impact of ocular chromatic aberration on the use of isoluminance gratings as a tool in spatial-color vision?. Using optical ray tracing methods, MTF analysis methods of image quality, and psychophysical methods, I have developed a more complete model of ocular chromatic aberrations and their effects on vision. The ocular CDM was determined psychophysically by measuring the tilt in the apparent frontal parallel plane (AFPP) induced by interocular difference in image wavelength. This experimental result was then used to verify a theoretical relationship between the ocular CDM, the ocular CDF and the entrance pupil of the eye. In the retinal image after correcting the ocular CDF with existing achromatizing methods, two forms of chromatic aberration (CDM and chromatic parallax) were examined. The CDM was predicted by theoretical ray tracing and measured with the same method used to determine ocular CDM. The chromatic parallax was predicted with a nodal ray model and measured with the two-color vernier alignment method. The influence of these two aberrations on polychromatic MTF were calculated. Using this improved model of ocular chromatic aberration, luminance artifacts in the images of isoluminance gratings were calculated. The predicted luminance artifacts were then compared with experimental data from previous investigators. The results show that: (1) A simple relationship exists between two major chromatic aberrations and the location of the pupil; (2) The ocular CDM is measurable and varies among individuals; (3) All existing methods to correct ocular chromatic aberration face another aberration, chromatic parallax, which is inherent in the methodology; (4) Ocular chromatic aberrations have the potential to contaminate psychophysical experimental results on human spatial-color vision.

  4. Chromatic induction from surrounding stimuli under perceptual suppression.

    PubMed

    Horiuchi, Koji; Kuriki, Ichiro; Tokunaga, Rumi; Matsumiya, Kazumichi; Shioiri, Satoshi

    2014-11-01

    The appearance of colors can be affected by their spatiotemporal context. The shift in color appearance according to the surrounding colors is called color induction or chromatic induction; in particular, the shift in opponent color of the surround is called chromatic contrast. To investigate whether chromatic induction occurs even when the chromatic surround is imperceptible, we measured chromatic induction during interocular suppression. A multicolor or uniform color field was presented as the surround stimulus, and a colored continuous flash suppression (CFS) stimulus was presented to the dominant eye of each subject. The subjects were asked to report the appearance of the test field only when the stationary surround stimulus is invisible by interocular suppression with CFS. The resulting shifts in color appearance due to chromatic induction were significant even under the conditions of interocular suppression for all surround stimuli. The magnitude of chromatic induction differed with the surround conditions, and this difference was preserved regardless of the viewing conditions. The chromatic induction effect was reduced by CFS, in proportion to the magnitude of chromatic induction under natural (i.e., no-CFS) viewing conditions. According to an analysis with linear model fitting, we revealed the presence of at least two kinds of subprocesses for chromatic induction that reside at higher and lower levels than the site of interocular suppression. One mechanism yields different degrees of chromatic induction based on the complexity of the surround, which is unaffected by interocular suppression, while the other mechanism changes its output with interocular suppression acting as a gain control. Our results imply that the total chromatic induction effect is achieved via a linear summation of outputs from mechanisms that reside at different levels of visual processing.

  5. Luminance cues constrain chromatic blur discrimination in natural scene stimuli.

    PubMed

    Sharman, Rebecca J; McGraw, Paul V; Peirce, Jonathan W

    2013-03-22

    Introducing blur into the color components of a natural scene has very little effect on its percept, whereas blur introduced into the luminance component is very noticeable. Here we quantify the dominance of luminance information in blur detection and examine a number of potential causes. We show that the interaction between chromatic and luminance information is not explained by reduced acuity or spatial resolution limitations for chromatic cues, the effective contrast of the luminance cue, or chromatic and achromatic statistical regularities in the images. Regardless of the quality of chromatic information, the visual system gives primacy to luminance signals when determining edge location. In natural viewing, luminance information appears to be specialized for detecting object boundaries while chromatic information may be used to determine surface properties.

  6. The first prototype of chromatic pupillometer for objective perimetry in retinal degeneration patients

    NASA Astrophysics Data System (ADS)

    Rotenstreich, Ygal; Chibel, Ron; Haj Yahia, Soad; Achiron, Asaf; Mahajna, Mohamad; Belkin, Michael; Sher, Ifat

    2015-03-01

    We recently demonstrated the feasibility of quantifying pupil responses (PR) to multifocal chromatic light stimuli for objectively assessing visual field (VF). Here we assessed a second-generation chromatic multifocal pupillometer device with 76 LEDs of 18 degree visual field and a smaller spot size (2mm diameter), aimed of achieving better perimetric resolution. A computerized infrared pupillometer was used to record PR to short- and long-wavelength stimuli (peak 485 nm and 640 nm, respectively) presented by 76 LEDs, 1.8mm spot size, at light intensities of 10-1000 cd/m2 at different points of the 18 degree VF. PR amplitude was measured in 11 retinitis pigmentosa (RP) patients and 20 normal agedmatched controls. RP patients demonstrated statistically significant reduced pupil contraction amplitude in majority of perimetric locations under testing conditions that emphasized rod contribution (short-wavelength stimuli at 200 cd/m2) in peripheral locations (p<0.05). By contrast, the amplitude of pupillary responses under testing conditions that emphasized cone cell contribution (long-wavelength stimuli at 1000 cd/m2) were not significantly different between the groups in majority of perimetric locations, particularly in central locations. Minimal pupil contraction was recorded in areas that were non-detected by chromatic Goldmann. This study demonstrates the feasibility of using pupillometerbased chromatic perimetry for objectively assessing VF defects and retinal function in patients with retinal degeneration. This method may be used to distinguish between the damaged cells underlying the VF defect.

  7. chroma: Chromatic effects for LSST weak lensing

    NASA Astrophysics Data System (ADS)

    Meyers, Joshua E.; Burchat, Patricia R.

    2018-04-01

    Chroma investigates biases originating from two chromatic effects in the atmosphere: differential chromatic refraction (DCR), and wavelength dependence of seeing. These biases arise when using the point spread function (PSF) measured with stars to estimate the shapes of galaxies with different spectral energy distributions (SEDs) than the stars.

  8. Bandwidth correction for LED chromaticity based on Levenberg-Marquardt algorithm

    NASA Astrophysics Data System (ADS)

    Huang, Chan; Jin, Shiqun; Xia, Guo

    2017-10-01

    Light emitting diode (LED) is widely employed in industrial applications and scientific researches. With a spectrometer, the chromaticity of LED can be measured. However, chromaticity shift will occur due to the broadening effects of the spectrometer. In this paper, an approach is put forward to bandwidth correction for LED chromaticity based on Levenberg-Marquardt algorithm. We compare chromaticity of simulated LED spectra by using the proposed method and differential operator method to bandwidth correction. The experimental results show that the proposed approach achieves an excellent performance in bandwidth correction which proves the effectiveness of the approach. The method has also been tested on true blue LED spectra.

  9. Max Schottelius: Pioneer in Pheochromocytoma

    PubMed Central

    Tischler, Arthur S.; Schmid, Kurt W.; Leijon, Helena; Eng, Charis; Neumann, Hartmut P. H.

    2017-01-01

    First descriptions of diseases attract tremendous interest because they reveal scientific insight even in retrospect. Max Schottelius, the pathologist contributing the first histological description of pheochromocytoma, remains anonymous. We reviewed the description by Schottelius and weighed the report in modern context. Schottelius described the classical diagnostic elements of pheochromocytoma, including the brown appearance after exposure to chromate-containing Mueller’s fixative. This color change, known as chromaffin reaction, results from oxidation of catecholamines and is reflected in the name pheochromocytoma, meaning dusky-colored chromate-positive tumor. Thus Schottelius performed the first known histochemical contribution to diagnosis, which is today standard with immunohistochemistry for chromogranin. PMID:29264546

  10. Chromatic Perceptual Learning but No Category Effects without Linguistic Input.

    PubMed

    Grandison, Alexandra; Sowden, Paul T; Drivonikou, Vicky G; Notman, Leslie A; Alexander, Iona; Davies, Ian R L

    2016-01-01

    Perceptual learning involves an improvement in perceptual judgment with practice, which is often specific to stimulus or task factors. Perceptual learning has been shown on a range of visual tasks but very little research has explored chromatic perceptual learning. Here, we use two low level perceptual threshold tasks and a supra-threshold target detection task to assess chromatic perceptual learning and category effects. Experiment 1 investigates whether chromatic thresholds reduce as a result of training and at what level of analysis learning effects occur. Experiment 2 explores the effect of category training on chromatic thresholds, whether training of this nature is category specific and whether it can induce categorical responding. Experiment 3 investigates the effect of category training on a higher level, lateralized target detection task, previously found to be sensitive to category effects. The findings indicate that performance on a perceptual threshold task improves following training but improvements do not transfer across retinal location or hue. Therefore, chromatic perceptual learning is category specific and can occur at relatively early stages of visual analysis. Additionally, category training does not induce category effects on a low level perceptual threshold task, as indicated by comparable discrimination thresholds at the newly learned hue boundary and adjacent test points. However, category training does induce emerging category effects on a supra-threshold target detection task. Whilst chromatic perceptual learning is possible, learnt category effects appear to be a product of left hemisphere processing, and may require the input of higher level linguistic coding processes in order to manifest.

  11. REDUCTIVE DETOXIFICATION AND IMMOBILIZATION OF CHROMATE PRESENT IN SOILS

    EPA Science Inventory

    The in-situ permeable reactive barrier at the U.S. Coast Guard Air Support Center at Elizabeth City, North Carolina is very effective in remediating the contaminant plumes of TCE and chromate in the ground water, but it has limited effectiveness to attenuate chromate present as s...

  12. Luminance and chromatic signals interact differently with melanopsin activation to control the pupil light response.

    PubMed

    Barrionuevo, Pablo A; Cao, Dingcai

    2016-09-01

    Intrinsically photosensitive retinal ganglion cells (ipRGCs) express the photopigment melanopsin. These cells receive afferent inputs from rods and cones, which provide inputs to the postreceptoral visual pathways. It is unknown, however, how melanopsin activation is integrated with postreceptoral signals to control the pupillary light reflex. This study reports human flicker pupillary responses measured using stimuli generated with a five-primary photostimulator that selectively modulated melanopsin, rod, S-, M-, and L-cone excitations in isolation, or in combination to produce postreceptoral signals. We first analyzed the light adaptation behavior of melanopsin activation and rod and cones signals. Second, we determined how melanopsin is integrated with postreceptoral signals by testing with cone luminance, chromatic blue-yellow, and chromatic red-green stimuli that were processed by magnocellular (MC), koniocellular (KC), and parvocellular (PC) pathways, respectively. A combined rod and melanopsin response was also measured. The relative phase of the postreceptoral signals was varied with respect to the melanopsin phase. The results showed that light adaptation behavior for all conditions was weaker than typical Weber adaptation. Melanopsin activation combined linearly with luminance, S-cone, and rod inputs, suggesting the locus of integration with MC and KC signals was retinal. The melanopsin contribution to phasic pupil responses was lower than luminance contributions, but much higher than S-cone contributions. Chromatic red-green modulation interacted with melanopsin activation nonlinearly as described by a "winner-takes-all" process, suggesting the integration with PC signals might be mediated by a postretinal site.

  13. Objective assessment of chromatic and achromatic pattern adaptation reveals the temporal response properties of different visual pathways.

    PubMed

    Robson, Anthony G; Kulikowski, Janus J

    2012-11-01

    The aim was to investigate the temporal response properties of magnocellular, parvocellular, and koniocellular visual pathways using increment/decrement changes in contrast to elicit visual evoked potentials (VEPs). Static achromatic and isoluminant chromatic gratings were generated on a monitor. Chromatic gratings were modulated along red/green (R/G) or subject-specific tritanopic confusion axes, established using a minimum distinct border criterion. Isoluminance was determined using minimum flicker photometry. Achromatic and chromatic VEPs were recorded to contrast increments and decrements of 0.1 or 0.2 superimposed on the static gratings (masking contrast 0-0.6). Achromatic increment/decrement changes in contrast evoked a percept of apparent motion when the spatial frequency was low; VEPs to such stimuli were positive in polarity and largely unaffected by high levels of static contrast, consistent with transient response mechanisms. VEPs to finer achromatic gratings showed marked attenuation as static contrast was increased. Chromatic VEPs to R/G or tritan chromatic contrast increments were of negative polarity and showed progressive attenuation as static contrast was increased, in keeping with increasing desensitization of the sustained responses of the color-opponent visual pathways. Chromatic contrast decrement VEPs were of positive polarity and less sensitive to pattern adaptation. The relative contribution of sustained/transient mechanisms to achromatic processing is spatial frequency dependent. Chromatic contrast increment VEPs reflect the sustained temporal response properties of parvocellular and koniocellular pathways. Cortical VEPs can provide an objective measure of pattern adaptation and can be used to probe the temporal response characteristics of different visual pathways.

  14. Traverse Focusing of Intense Charged Particle Beams with Chromatic Effects for Heavy Ion Fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James M. Mitrani, Igor D. Kaganovich, Ronald C. Davidson

    A fi nal focusing scheme designed to minimize chromatic effects is discussed. The Neutralized Drift Compression Experiment-II (NDCX-II) will apply a velocity tilt for longitudinal bunch compression, and a fi nal focusing solenoid (FFS) for transverse bunch compression. In the beam frame, neutralized drift compression causes a suffi ciently large spread in axial momentum, pz , resulting in chromatic effects to the fi nal focal spot during transverse bunch compression. Placing a weaker solenoid upstream of a stronger fi nal focusing solenoid (FFS) mitigates chromatic effects and improves transverse focusing by a factor of approximately 2-4 for appropriate NDCX-II parameters.

  15. Comparative Genotoxicity and Cytotoxicity of Four Hexavalent Chromium Compounds in Human Bronchial Cells

    PubMed Central

    Wise, Sandra S.; Holmes, Amie L.; Qin, Qin; Xie, Hong; Katsifis, Spiros P.; Thompson, W. Douglas; Wise, John Pierce

    2010-01-01

    Hexavalent chromium (Cr(VI)) compounds are well-established human lung carcinogens. Solubility plays an important role in their carcinogenicity with the particulate Cr(VI) compounds being the most carcinogenic. Epidemiology and animal studies suggest that zinc chromate is the most potent particulate Cr(VI) compound, however, there are few comparative data to support these observations. The purpose of this study was to compare the genotoxicity of zinc chromate with two other particulate Cr(VI) compounds, barium chromate and lead chromate, and one soluble Cr(VI) compound, sodium chromate. The clastogenic effects of barium chromate and zinc chromate were similar but lead chromate induced significantly less damage. The levels of DNA damage measured by gamma-H2A.X foci formation were similar for the three particulate chromium compounds. Corrected for chromium uptake differences, we found that zinc chromate and barium chromate were the most cytotoxic and lead chromate and sodium chromate were less cytotoxic. Zinc chromate was more clastogenic than all other chromium compounds and lead chromate was the least clastogenic. There was no significant difference between any of the compounds for the induction of DNA double strand breaks. All together, these data suggest that the difference in the carcinogenic potency of zinc chromate over the other chromium compounds is not due solely to a difference in chromium ion uptake and the zinc cation may in fact have an important role in its carcinogenicity. PMID:20000473

  16. S-cone discrimination in the presence of two adapting fields: data and model

    PubMed Central

    Cao, Dingcai

    2014-01-01

    This study investigated S-cone discrimination using a test annulus surrounded by an inner and outer adapting field with systematic manipulation of the adapting l = L/(L + M) or s = S/(L + M) chromaticities. The results showed that different adapting l chromaticities altered S-cone discrimination for a high adapting s chromaticity due to parvocellular input to the koniocellular pathway. In addition, S-cone discrimination was determined by the combined spectral signals arising from both adapting fields. The “white” adapting field or an adapting field with a different l chromaticity from the other fields was more likely to have a stronger influence on discrimination thresholds. These results indicated that the two cardinal axes are not independent in S-cone discrimination, and the two adapting fields jointly contribute to S-cone discrimination through a cortical summation mechanism. PMID:24695204

  17. Measurement uncertainty associated with chromatic confocal profilometry for 3D surface texture characterization of natural human enamel.

    PubMed

    Mullan, F; Bartlett, D; Austin, R S

    2017-06-01

    To investigate the measurement performance of a chromatic confocal profilometer for quantification of surface texture of natural human enamel in vitro. Contributions to the measurement uncertainty from all potential sources of measurement error using a chromatic confocal profilometer and surface metrology software were quantified using a series of surface metrology calibration artifacts and pre-worn enamel samples. The 3D surface texture analysis protocol was optimized across 0.04mm 2 of natural and unpolished enamel undergoing dietary acid erosion (pH 3.2, titratable acidity 41.3mmolOH/L). Flatness deviations due to the x, y stage mechanical movement were the major contribution to the measurement uncertainty; with maximum Sz flatness errors of 0.49μm. Whereas measurement noise; non-linearity's in x, y, z and enamel sample dimensional instability contributed minimal errors. The measurement errors were propagated into an uncertainty budget following a Type B uncertainty evaluation in order to calculate the Standard Combined Uncertainty (u c ), which was ±0.28μm. Statistically significant increases in the median (IQR) roughness (Sa) of the polished samples occurred after 15 (+0.17 (0.13)μm), 30 (+0.12 (0.09)μm) and 45 (+0.18 (0.15)μm) min of erosion (P<0.001 vs. baseline). In contrast, natural unpolished enamel samples revealed a statistically significant decrease in Sa roughness of -0.14 (0.34) μm only after 45min erosion (P<0.05s vs. baseline). The main contribution to measurement uncertainty using chromatic confocal profilometry was from flatness deviations however by optimizing measurement protocols the profilometer successfully characterized surface texture changes in enamel from erosive wear in vitro. Copyright © 2017 The Academy of Dental Materials. All rights reserved.

  18. A linear chromatic mechanism drives the pupillary response.

    PubMed Central

    Tsujimura, S.; Wolffsohn, J. S.; Gilmartin, B.

    2001-01-01

    Previous studies have shown that a chromatic mechanism can drive pupil responses. The aim of this research was to clarify whether a linear or nonlinear chromatic mechanism drives pupillary responses by using test stimuli of various colours that are defined in cone contrast space. The pupil and accommodation responses evoked by these test stimuli were continuously and simultaneously objectively measured by photorefraction. The results with isochromatic and isoluminant stimuli showed that the accommodative level remained approximately constant (< 0.25 D change in mean level) even when the concurrent pupillary response was large (ca. 0.30 mm). The pupillary response to an isoluminant grating was sustained, delayed (by ca. 60 ms) and larger in amplitude than that for a isochromatic uniform stimulus, which supports previous work suggesting that the chromatic mechanism contributes to the pupillary response. In a second experiment, selected chromatic test gratings were used and isoresponse contours in cone contrast space were obtained. The results showed that the isoresponse contour in cone contrast space is well described (r(2) = 0.99) by a straight line with a positive slope. The results indicate that a /L - M/ linear chromatic mechanism, whereby a signal from the long wavelength cone is subtracted from that of the middle wavelength cone and vice versa, drives pupillary responses. PMID:11674867

  19. Chromatic Perceptual Learning but No Category Effects without Linguistic Input

    PubMed Central

    Grandison, Alexandra; Sowden, Paul T.; Drivonikou, Vicky G.; Notman, Leslie A.; Alexander, Iona; Davies, Ian R. L.

    2016-01-01

    Perceptual learning involves an improvement in perceptual judgment with practice, which is often specific to stimulus or task factors. Perceptual learning has been shown on a range of visual tasks but very little research has explored chromatic perceptual learning. Here, we use two low level perceptual threshold tasks and a supra-threshold target detection task to assess chromatic perceptual learning and category effects. Experiment 1 investigates whether chromatic thresholds reduce as a result of training and at what level of analysis learning effects occur. Experiment 2 explores the effect of category training on chromatic thresholds, whether training of this nature is category specific and whether it can induce categorical responding. Experiment 3 investigates the effect of category training on a higher level, lateralized target detection task, previously found to be sensitive to category effects. The findings indicate that performance on a perceptual threshold task improves following training but improvements do not transfer across retinal location or hue. Therefore, chromatic perceptual learning is category specific and can occur at relatively early stages of visual analysis. Additionally, category training does not induce category effects on a low level perceptual threshold task, as indicated by comparable discrimination thresholds at the newly learned hue boundary and adjacent test points. However, category training does induce emerging category effects on a supra-threshold target detection task. Whilst chromatic perceptual learning is possible, learnt category effects appear to be a product of left hemisphere processing, and may require the input of higher level linguistic coding processes in order to manifest. PMID:27252669

  20. Study of chromatic adaptation via neutral white matches on different viewing media.

    PubMed

    Zhai, Qiyan; Luo, Ming R

    2018-03-19

    Two experiments were carried out to study the neutral white and the chromatic adaptation in human vision and color science. After matching neutral whites under different illuminants using both surface and self-luminous colors, the result were used to verify the previous study about the chromatic adaptation. Not all the white illuminants were found neutral even the adaptation time is long. The baseline illuminant of the two-step chromatic adaptation transform was found as the illuminant with the same chromaticity of the neutral white under it and depended on viewing medium in the present study. The results were also used as corresponding colors to derive models of the effective degree of chromatic adaptation, which were found highly associated with the chromaticity of the adapting illuminant.

  1. Mitigating chromatic effects for the transverse focusing of intense charged particle beams

    NASA Astrophysics Data System (ADS)

    Mitrani, James; Kaganovich, Igor; Davidson, Ronald

    2013-09-01

    A final focusing scheme designed to minimize chromatic effects is discussed. Solenoids are often used for transverse focusing in accelerator systems that require a charged particle beam with a small focal spot and/or large energy density A sufficiently large spread in axial momentum will reduce the effectiveness of transverse focusing, and result in chromatic effects on the final focal spot. Placing a weaker solenoid upstream of a stronger final focusing solenoid (FFS) mitigates chromatic effects on transverse beam focusing. J.M. Mitrani et al., Nucl. Inst. Meth. Phys. Res. A (2013) http://dx.doi.org/10.1016/j.nima.2013.05.09 This work was supported by DOE contract DE-AC02-09CH11466.

  2. Replacement of chromates in paints and corrosion protection systems [Stage 2

    DOT National Transportation Integrated Search

    2004-05-01

    This technical report presents the second stage results of a multi-year project to develop chromate-free paints and corrosion protection systems. Chromate-containing coatings and paints are very effective in providing corrosion resistance and are wid...

  3. Nonlocal interactions in color perception: nonlinear processing of chromatic signals from remote inducers.

    PubMed

    Wachtler, T; Albright, T D; Sejnowski, T J

    2001-05-01

    The perceived color of an object depends on the chromaticity of its immediate background. But color appearance is also influenced by remote chromaticities. To quantify these influences, the effects of remote color fields on the appearance of a fixated 2 degrees test field were measured using a forced-choice method. Changes in the appearance of the test field were induced by chromaticity changes of the background and of 2 degrees color fields not adjacent to the test field. The appearance changes induced by the color of the background corresponded to a fraction of between 0.5 and 0.95 of the cone contrast of the background change, depending on the observer. The magnitude of induction by the background color was modulated on average by 7.6% by chromaticity changes in the remote color fields. Chromaticity changes in the remote fields had virtually no inducing effect when they occurred without a change in background color. The spatial range of these chromatic interactions extended over at least 10 degrees from the fovea. They were established within the first few hundred milliseconds after the change of background color and depended only weakly on the number of inducing fields. These results may be interpreted as reflecting rapid chromatic interactions that support robustness of color vision under changing viewing conditions.

  4. Informational primacy of visual dimensions: specialized roles for luminance and chromaticity in figure-ground perception.

    PubMed

    Yamagishi, N; Melara, R D

    2001-07-01

    Three experiments were conducted to examine the distinct contributions of two visual dimensions to figure-ground segregation. In each experiment, pattern identification was assessed by asking observers to judge whether a near-threshold test pattern was the same or different in shape to a high-contrast comparison pattern. A test pattern could differ from its background along one dimension, either luminance (luminance tasks) or chromaticity (chromaticity tasks). In each task, performance in a baseline condition, in which the test pattern was intact, was compared with performance in each of several degradation conditions, in which either the contour or the surface of the figure was degraded, using either partial occlusion (Experiment 1) or ramping (Experiments 2 and 3) of figure-ground differences. In each experiment, performance in luminance tasks was worst when the contour was degraded, whereas performance in chromaticity tasks was worst when the surface was degraded. This interaction was found even when spatial frequencies were fixed across test patterns by low-pass filtering. The results are consistent with a late (postfiltering) dual-mechanism system that processes luminance information to extract boundary representations and chromaticity information to extract surface representations.

  5. Detailed spatiotemporal brain mapping of chromatic vision combining high-resolution VEP with fMRI and retinotopy.

    PubMed

    Pitzalis, Sabrina; Strappini, Francesca; Bultrini, Alessandro; Di Russo, Francesco

    2018-03-13

    Neuroimaging studies have identified so far, several color-sensitive visual areas in the human brain, and the temporal dynamics of these activities have been separately investigated using the visual-evoked potentials (VEPs). In the present study, we combined electrophysiological and neuroimaging methods to determine a detailed spatiotemporal profile of chromatic VEP and to localize its neural generators. The accuracy of the present co-registration study was obtained by combining standard fMRI data with retinotopic and motion mapping data at the individual level. We found a sequence of occipito activities more complex than that typically reported for chromatic VEPs, including feed-forward and reentrant feedback. Results showed that chromatic human perception arises by the combined activity of at the least five parieto-occipital areas including V1, LOC, V8/VO, and the motion-sensitive dorsal region MT+. However, the contribution of V1 and V8/VO seems dominant because the re-entrant activity in these areas was present more than once (twice in V8/VO and thrice in V1). This feedforward and feedback chromatic processing appears delayed compared with the luminance processing. Associating VEPs and neuroimaging measures, we showed for the first time a complex spatiotemporal pattern of activity, confirming that chromatic stimuli produce intricate interactions of many different brain dorsal and ventral areas. © 2018 Wiley Periodicals, Inc.

  6. Chromatic characterization of a three-channel colorimeter using back-propagation neural networks

    NASA Astrophysics Data System (ADS)

    Pardo, P. J.; Pérez, A. L.; Suero, M. I.

    2004-09-01

    This work describes a method for the chromatic characterization of a three-channel colorimeter of recent design and construction dedicated to color vision research. The colorimeter consists of two fixed monochromators and a third monochromator interchangeable with a cathode ray tube or any other external light source. Back-propagation neural networks were used for the chromatic characterization to establish the relationship between each monochromator's input parameters and the tristimulus values of each chromatic stimulus generated. The results showed the effectiveness of this type of neural-network-based system for the chromatic characterization of the stimuli produced by any monochromator.

  7. Direct design of achromatic lens for Lambertian sources in collimating illumination

    NASA Astrophysics Data System (ADS)

    Yin, Peng; Xu, Xiping; Jiang, Zhaoguo; Wang, Hongshu

    2017-10-01

    Illumination design used to redistribute the spatial energy distribution of light source is a key technique in lighting applications. However, there is still no effective illumination design method for the removing of the chromatic dispersion. What we present here is an achromatic lens design to enhance the efficiency and uniform illumination of white light-emitting diode (LED) with diffractive optical element (DOE). We employ the chromatic aberration value (deg) to measure the degree of chromatic dispersion in illumination systems. Monte Carlo ray tracing simulation results indicate that the chromatic dispersion of the modified achromatic collimator significantly decreases from 0.5 to 0.1 with LED chip size of 1.0mm×1.0mm and simulation efficiency of 90.73%, compared with the traditional collimator. Moreover, with different corrected wavelengths we compared different chromatic aberration values that followed with the changing pupil percent. The achromatic collimator provided an effective way to achieve white LED with low chromatic dispersion at high efficiency and uniform illumination.

  8. Camera processing with chromatic aberration.

    PubMed

    Korneliussen, Jan Tore; Hirakawa, Keigo

    2014-10-01

    Since the refractive index of materials commonly used for lens depends on the wavelengths of light, practical camera optics fail to converge light to a single point on an image plane. Known as chromatic aberration, this phenomenon distorts image details by introducing magnification error, defocus blur, and color fringes. Though achromatic and apochromatic lens designs reduce chromatic aberration to a degree, they are complex and expensive and they do not offer a perfect correction. In this paper, we propose a new postcapture processing scheme designed to overcome these problems computationally. Specifically, the proposed solution is comprised of chromatic aberration-tolerant demosaicking algorithm and post-demosaicking chromatic aberration correction. Experiments with simulated and real sensor data verify that the chromatic aberration is effectively corrected.

  9. Effects of chromatic image statistics on illumination induced color differences.

    PubMed

    Lucassen, Marcel P; Gevers, Theo; Gijsenij, Arjan; Dekker, Niels

    2013-09-01

    We measure the color fidelity of visual scenes that are rendered under different (simulated) illuminants and shown on a calibrated LCD display. Observers make triad illuminant comparisons involving the renderings from two chromatic test illuminants and one achromatic reference illuminant shown simultaneously. Four chromatic test illuminants are used: two along the daylight locus (yellow and blue), and two perpendicular to it (red and green). The observers select the rendering having the best color fidelity, thereby indirectly judging which of the two test illuminants induces the smallest color differences compared to the reference. Both multicolor test scenes and natural scenes are studied. The multicolor scenes are synthesized and represent ellipsoidal distributions in CIELAB chromaticity space having the same mean chromaticity but different chromatic orientations. We show that, for those distributions, color fidelity is best when the vector of the illuminant change (pointing from neutral to chromatic) is parallel to the major axis of the scene's chromatic distribution. For our selection of natural scenes, which generally have much broader chromatic distributions, we measure a higher color fidelity for the yellow and blue illuminants than for red and green. Scrambled versions of the natural images are also studied to exclude possible semantic effects. We quantitatively predict the average observer response (i.e., the illuminant probability) with four types of models, differing in the extent to which they incorporate information processing by the visual system. Results show different levels of performance for the models, and different levels for the multicolor scenes and the natural scenes. Overall, models based on the scene averaged color difference have the best performance. We discuss how color constancy algorithms may be improved by exploiting knowledge of the chromatic distribution of the visual scene.

  10. Effect of Kombucha tea on chromate(VI)-induced oxidative stress in albino rats.

    PubMed

    Sai Ram, M; Anju, B; Pauline, T; Dipti, P; Kain, A K; Mongia, S S; Sharma, S K; Singh, B; Singh, R; Ilavazhagan, G; Kumar, D; Selvamurthy, W

    2000-07-01

    The effect of Kombucha tea (KT) on oxidative stress induced changes in rats subjected to chromate treatment are reported. KT feeding alone did not show any significant change in malondialdehyde (MDA) and reduced glutathione (GSH) levels, but did enhance humoral response and delayed type of hypersensitivity (DTH) response appreciably over control animals. Chromate treatment significantly enhanced plasma and tissue MDA levels, decreased DTH response considerably, enhanced glutathione peroxidase and catalase activities; however, no change in GSH, superoxide dismutase and antibody titres was noticed. KT feeding completely reversed the chromate-induced changes. These results show that Kombucha tea has potent anti-oxidant and immunopotentiating activities.

  11. Chromatic aberrations correction for imaging spectrometer based on acousto-optic tunable filter with two transducers.

    PubMed

    Zhao, Huijie; Wang, Ziye; Jia, Guorui; Zhang, Ying; Xu, Zefu

    2017-10-02

    The acousto-optic tunable filter (AOTF) with wide wavelength range and high spectral resolution has long crystal and two transducers. A longer crystal length leads to a bigger chromatic focal shift and the double-transducer arrangement induces angular mutation in diffracted beam, which increase difficulty in longitudinal and lateral chromatic aberration correction respectively. In this study, the two chromatic aberrations are analyzed quantitatively based on an AOTF optical model and a novel catadioptric dual-path configuration is proposed to correct both the chromatic aberrations. The test results exhibit effectiveness of the optical configuration for this type of AOTF-based imaging spectrometer.

  12. Effect of ocular transverse chromatic aberration on detection acuity for peripheral vision.

    PubMed

    Cheney, Frank; Thibos, Larry; Bradley, Arthur

    2015-01-01

    We examined the effect of transverse chromatic aberration (TCA) on detection acuity for white-light interference fringes seen in Maxwellian view at various orientations and locations in the visual field. A circular patch (3.5° diameter, 3.2 log Trolands) of nominally high-contrast fringes was produced on the retina by a commercial instrument (the Lotmar Visometer, Haag Streit) mounted on a gimbal for controlled positioning of the stimulus in the visual field from 0° to 35° eccentricity. Detection acuity for white light fringes for all meridians and eccentricities ≥15° was maximum when fringes were oriented parallel to the visual meridian line. This meridional effect disappeared when a narrow-band filter was used to eliminate TCA. The meridional effect also disappeared when the interferometric stimulator was displaced laterally to align the instrument with the eye's local achromatic axis. Modelling confirmed that TCA is the major factor responsible for white-light meridional bias, with minor contribution arising from higher-order monochromatic aberrations and neural factors. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  13. Chromium-induced kidney disease.

    PubMed

    Wedeen, R P; Qian, L F

    1991-05-01

    Kidney disease is often cited as one of the adverse effects of chromium, yet chronic renal disease due to occupational or environmental exposure to chromium has not yet been reported. Occasional cases of acute tubular necrosis (ATN) following massive absorption of chromate have been described. Chromate-induced ATN has been extensively studied in experimental animals following parenteral administration of large doses of potassium chromate (hexavalent) (15 mg/kg body weight). The chromate is selectively accumulated in the convoluted proximal tubule where necrosis occurs. An adverse long-term effect of low-dose chromium exposure on the kidneys is suggested by reports of low molecular weight (LMW) proteinuria in chromium workers. Excessive urinary excretion of beta 2-microglobulin, a specific proximal tubule brush border protein, and retinol-binding protein has been reported among chrome platers and welders. However, LMW proteinuria occurs after a variety of physiologic stresses, is usually reversible, and cannot by itself be considered evidence of chronic renal disease. Chromate-induced ATN and LMW proteinuria in chromium workers, nevertheless, raise the possibility that low-level, long-term exposure may produce persistent renal injury. The absence of evidence of chromate-induced exposure may produce persistent renal injury. The absence of evidence of chromate-induced chronic renal disease cannot be interpreted as evidence of the absence of such injury. Rather, it must be recognized that no prospective cohort or case-control study of the delayed renal effects of low-level, long-term exposure to chromium has been published.

  14. Visual sensitivity for luminance and chromatic stimuli during the execution of smooth pursuit and saccadic eye movements.

    PubMed

    Braun, Doris I; Schütz, Alexander C; Gegenfurtner, Karl R

    2017-07-01

    Visual sensitivity is dynamically modulated by eye movements. During saccadic eye movements, sensitivity is reduced selectively for low-spatial frequency luminance stimuli and largely unaffected for high-spatial frequency luminance and chromatic stimuli (Nature 371 (1994), 511-513). During smooth pursuit eye movements, sensitivity for low-spatial frequency luminance stimuli is moderately reduced while sensitivity for chromatic and high-spatial frequency luminance stimuli is even increased (Nature Neuroscience, 11 (2008), 1211-1216). Since these effects are at least partly of different polarity, we investigated the combined effects of saccades and smooth pursuit on visual sensitivity. For the time course of chromatic sensitivity, we found that detection rates increased slightly around pursuit onset. During saccades to static and moving targets, detection rates dropped briefly before the saccade and reached a minimum at saccade onset. This reduction of chromatic sensitivity was present whenever a saccade was executed and it was not modified by subsequent pursuit. We also measured contrast sensitivity for flashed high- and low-spatial frequency luminance and chromatic stimuli during saccades and pursuit. During saccades, the reduction of contrast sensitivity was strongest for low-spatial frequency luminance stimuli (about 90%). However, a significant reduction was also present for chromatic stimuli (about 58%). Chromatic sensitivity was increased during smooth pursuit (about 12%). These results suggest that the modulation of visual sensitivity during saccades and smooth pursuit is more complex than previously assumed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Cement-Induced Chromate Occupational Allergic Contact Dermatitis.

    PubMed

    Kridin, Khalaf; Bergman, Reuven; Khamaisi, Mogher; Zelber-Sagi, Shira; Weltfriend, Sara

    2016-01-01

    Hexavalent chromium in cement is a common cause of occupational allergic contact dermatitis (OACD). Analysis of patch test data during 1999 to 2013 was done. Patients with cement-induced chromate OACD filled the Dermatology Life Quality Index, graded 1 to 5. Of 4846 consecutive patients who were patch tested, 146 (3%) were chromate-sensitive. Of 46 (31.5%) who presented with chromate OACD, 27 (59%) had cement-induced chromate OACD. The proportion of chromate-sensitive patients with clinically relevant cement exposure increased from 7.7% in 2002 to 2004 to 28.7% in 2011 to 2013 (P = 0.04). The median age of presentation was younger than for other chromate-sensitive patients (32 vs 42 years). Hand eczema (88.9%) was the most frequent clinical presentation. Of the 27 with cement-induced chromate OACD, 21 (77.8%) had ongoing dermatitis at the time of the review. Although 14/27 (51.9%) changed their occupation to avoid exposure to cement, symptoms persisted in 9/14 (64.3%). Prolonged exposure to cement before development of symptoms was associated with chronicity. All the symptomatic patients experienced at least a moderate effect on their quality of life (grade 3 or higher on the Dermatology Life Quality Index). We recommend the adoption of the European legislation in Israel, to reduce the prevalence of chromate OACD from cement.

  16. High-performance lighting evaluated by photobiological parameters.

    PubMed

    Rebec, Katja Malovrh; Gunde, Marta Klanjšek

    2014-08-10

    The human reception of light includes image-forming and non-image-forming effects which are triggered by spectral distribution and intensity of light. Ideal lighting is similar to daylight, which could be evaluated by spectral or chromaticity match. LED-based and CFL-based lighting were analyzed here, proposed according to spectral and chromaticity match, respectively. The photobiological effects were expressed by effectiveness for blue light hazard, cirtopic activity, and photopic vision. Good spectral match provides light with more similar effects to those obtained by the chromaticity match. The new parameters are useful for better evaluation of complex human responses caused by lighting.

  17. An unbiased measure of the contributions of chroma and luminance to saccadic suppression of displacement.

    PubMed

    Anand, Sulekha; Bridgeman, Bruce

    2002-02-01

    Perception of image displacement is suppressed during saccadic eye movements. We probed the source of saccadic suppression of displacement by testing whether it selectively affects chromatic- or luminance-based motion information. Human subjects viewed a stimulus in which chromatic and luminance cues provided conflicting information about displacement direction. Apparent motion occurred during either fixation or a 19.5 degree saccade. Subjects detected motion and discriminated displacement direction in each trial. They reported motion in over 90% of fixation trials and over 70% of saccade trials. During fixation, the probability of perceiving the direction carried by chromatic cues decreased as luminance contrast increased. During saccades, subjects tended to perceive the direction indicated by luminance cues when luminance contrast was high. However, when luminance contrast was low, subjects showed no preference for the chromatic- or luminance-based direction. Thus magnocellular channels are suppressed, while stimulation of parvocellular channels is below threshold, so that neither channel drives motion perception during saccades. These results confirm that magnocellular inhibition is the source of saccadic suppression.

  18. Edges, colour and awareness in blindsight.

    PubMed

    Alexander, Iona; Cowey, Alan

    2010-06-01

    It remains unclear what is being processed in blindsight in response to faces, colours, shapes, and patterns. This was investigated in two hemianopes with chromatic and achromatic stimuli with sharp or shallow luminance or chromatic contrast boundaries or temporal onsets. Performance was excellent only when stimuli had sharp spatial boundaries. When discrimination between isoluminant coloured Gaussians was good it declined to chance levels if stimulus onset was slow. The ability to discriminate between instantaneously presented colours in the hemianopic field depended on their luminance, indicating that wavelength discrimination totally independent of other stimulus qualities is absent. When presented with narrow-band colours the hemianopes detected a stimulus maximally effective for S-cones but invisible to M- and L-cones, indicating that blindsight is mediated not just by the mid-brain, which receives no S-cone input, or that the rods contribute to blindsight. The results show that only simple stimulus features are processed in blindsight. 2010 Elsevier Inc. All rights reserved.

  19. The Cytotoxicity and Genotoxicity of Hexavalent Chromium in Steller Sea Lion Lung Fibroblasts Compared to Human Lung Fibroblasts

    PubMed Central

    Wise, John Pierce; Wise, Sandra S.; Holmes, Amie L.; LaCerte, Carolyne; Shaffiey, Fariba; Aboueissa, AbouEl-Makarim

    2010-01-01

    In this study we directly compared soluble and particulate chromate cytotoxicity and genotoxicity in human (Homo sapiens) and sea lion (Eumetopias jubatus) lung fibroblasts. Our results show that hexavalent chromium induces increased cell death and chromosome damage in both human and sea lion cells with increasing intracellular chromium ion levels. The data further indicate that both sodium chromate and lead chromate are less cytotoxic and genotoxic to sea lion cells than human cells, based on administered dose. Differences in chromium ion uptake explained some but not all of the reduced amounts of sodium chromate-induced cell death. By contrast, uptake differences could explain the differences in sodium chromate-induced chromosome damage and particulate chromate-induced toxicity. Altogether they indicate that while hexavalent chromium induces similar toxic effects in sea lion and human cells, there are different mechanisms underlying the toxic outcomes. PMID:20211760

  20. Interactions between chromatic- and luminance-contrast-sensitive stereopsis mechanisms.

    PubMed

    Simmons, David R; Kingdom, Frederick A A

    2002-06-01

    It is well known that chromatic information can assist in solving the stereo correspondence problem. It has also been suggested that there are two independent first-order stereopsis mechanisms, one sensitive to chromatic contrast and the other sensitive to luminance contrast (Vision Research 37 (1997) 1271). Could the effect of chromatic information on stereo correspondence be subserved by interactions between these mechanisms? To address this question, disparity thresholds (1/stereoacuity) were measured using 0.5 cpd Gabor patches. The stimuli possessed different relative amounts of chromatic and luminance contrast which could be correlated or anti-correlated between the eyes. Stereoscopic performance with these compound stimuli was compared to that with purely isoluminant and isochromatic stimuli at different contrasts. It was found that anti-correlated chromatic contrast severely disrupted stereopsis with achromatic stimuli and that anti-correlated luminance contrast severely disrupted stereopsis with chromatic stimuli. Less dramatic, but still significant, was the improvement in stereoacuity obtained using correlated colour and luminance contrast. These data are consistent with there being positive and negative interactions between chromatic and achromatic stereopsis mechanisms that take place after the initial encoding of disparity information, but before the extraction of stereoscopic depth. These interactions can be modelled satisfactorily assuming probability summation of depth sign information between independent mechanisms.

  1. Chromatic blur perception in the presence of luminance contrast.

    PubMed

    Jennings, Ben J; Kingdom, Frederick A A

    2017-06-01

    Hel-Or showed that blurring the chromatic but not the luminance layer of an image of a natural scene failed to elicit any impression of blur. Subsequent studies have suggested that this effect is due either to chromatic blur being masked by spatially contiguous luminance edges in the scene (Journal of Vision 13 (2013) 14), or to a relatively compressed transducer function for chromatic blur (Journal of Vision 15 (2015) 6). To test between the two explanations we conducted experiments using as stimuli both images of natural scenes as well as simple edges. First, we found that in color-and-luminance images of natural scenes more chromatic blur was needed to perceptually match a given level of blur in an isoluminant, i.e. colour-only scene. However, when the luminance layer in the scene was rotated relative to the chromatic layer, thus removing the colour-luminance edge correlations, the matched blur levels were near equal. Both results are consistent with Sharman et al.'s explanation. Second, when observers matched the blurs of luminance-only with isoluminant scenes, the matched blurs were equal, against Kingdom et al.'s prediction. Third, we measured the perceived blur in a square-wave as a function of (i) contrast (ii) number of luminance edges and (iii) the relative spatial phase between the colour and luminance edges. We found that the perceived chromatic blur was dependent on both relative phase and the number of luminance edges, or dependent on the luminance contrast if only a single edge is present. We conclude that this Hel-Or effect is largely due to masking of chromatic blur by spatially contiguous luminance edges. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Understanding and controlling chromaticity shift in LED devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Lynn; Mills, Karmann; Lamvik, Michael

    Chromaticity shift in light-emitting diode (LED) devices arises from multiple mechanisms, and at least five different chromaticity shift modes (CSMs) have been identified to date. This paper focuses on the impacts of irreversible phosphor degradation as a cause of chromaticity shifts in LED devices. The nitride phosphors used to produce warm white LEDs are especially vulnerable to degradation due to thermal and chemical effects such as reactions with oxygen and water. As a result, LED devices utilizing these phosphors were found to undergo either a green shift or, less commonly, a red shift depending on the phosphor mix in themore » LED devices. These types of chromaticity shifts are classified as CSM-2 (green shift) and CSM-5 (red shift). This paper provides an overview of the kinetic processes responsible for green and red chromaticity shifts along with examples from accelerated stress testing of 6” downlights. Both CSMs appear to proceed through analogous mechanisms that are initiated at the surface of the phosphor. A green shift is produced by the surface oxidation of the nitride phosphor that changes the emission profile to lower wavelengths. As the surface oxidation reaction proceeds, reactant limitations slow the rate and bulk oxidation processes become more prevalent. We found that a red chromaticity shift arises from quenching of the green phosphor, also possibly due to surface reactions of oxygen, which shift the emission chromaticity in the red direction. In conclusion, we discuss the implications of these findings on projecting chromaticity.« less

  3. Organosilane self-assembled layers (SAMs) and hybrid silicate magnesium-rich primers for the corrosion protection of aluminum alloy 2024 T3

    NASA Astrophysics Data System (ADS)

    Wang, Duhua

    Although current chromate coatings function very well in corrosion protection for aircraft alloys, such as aluminum alloy 2024 T3, the U.S. Environmental Protection Agency is planning to totally ban the use of chromates as coating materials in the next decade or so because of their extremely toxic effect. For this purpose, both self-assembled layers and silicate magnesium-rich primers were tested to provide the corrosion protection for aluminum alloy. The long-term goal of this research is to develop a coating system to replace the current chromate coating for aircraft corrosion protection. Aluminum alloy 2024 T3 substrates were modified with self-assembled monolayer or multilayer thin films from different alkylsilane compounds. Mono-functional silanes, such as octadecyltrichlorosilane (C18SiCl3), can form a mixed hydrophobic monolayer or multilayer thin film on the aluminum oxide surface to provide a barrier to water and other electrolytes, so the corrosion resistance of the SAMs modified surface was increased significantly. On the other hand, the bi-functional silane self-assembly could attach the aluminum surface through the silicon headgroup while using its functional tailgroup to chemically bond the polymer coating, thus improving the adhesion between the aluminum substrate and coating substantially, and seems to contribute more to corrosion protection of aluminum substrate. Organosilanes were also combined with tetraethyl orthosilicate (TEOS) in propel ratios to form a sol-gel binder to make silicate magnesium-rich primers. Analogue to the inorganic zinc-rich coatings, the silicate magnesium-rich primers also showed excellent adhesion and solvent resistance. The sacrificial magnesium pigments and the chemically inert silicate binder both contribute to the anti-corrosion properties. Future studies will be focused on the formula optimization for better toughness, chemical resistance and anticorrosion performance.

  4. An alternate to chromate conversion coatings for the corrosion protection of aluminum 2024-T3

    NASA Astrophysics Data System (ADS)

    Guo, Ruiguang

    Corrosion of high-strength aluminum alloys used for airspace application is an expensive and serious problem. The most significant environmental factor contributing to the corrosion of these alloys is water condensed from humid air and contaminated with soluble chloride salts. The Al 2024 series used for aircraft are particularly susceptible to corrosion in aqueous chloride solutions due to alloying constituents such as copper and other impurities. Chromates are efficient inhibitors of corrosion of aluminum in near neutral aqueous environments containing aggressive anions such as chlorides. Usually, aluminum alloys are initially protected by chromate conversion coatings. Additional polymer coatings are sometimes added during exposure to corrosive atmospheres such as marine environments. Although chromate coatings are widely used, they require the use of noxious solutions, so they have always presented effluent disposal problems. There are health and safety concerns over the use of chromates due to their toxicity and carcinogenic nature and, as a consequence, the environmental and health risks associated with the use of such coatings will be restricted in the future. It was these health and safety concerns that led to the development of alternative non-toxic coating processes with comparable adhesion properties and corrosion protection. A variety of process technologies are under development and are vying for acceptance in industrial markets. As an alternate conversion coating, a new titanate conversion coating was systematically researched and developed. Research concentrated on producing passive surfaces from a simple titanate solution using an immersion process. The corrosion resistance of the treated surface has been evaluated using simple, rapid electrochemical techniques as well as a more long-term salt spray test. Passivation by titanate conversion treatment exhibits many similarities to chromate conversion treatment. Based on this study of corrosion protection of the titanate coating formed at different conditions, a possible formation mechanism of a titanate coating is proposed. A conclusion may be drawn that titanate coating seems to be a viable alternative to chromate coatings.

  5. Modeling and Simulation of the Visual Effects of Colored Filters

    DTIC Science & Technology

    2015-02-01

    chromaticity coordinates on the MCC under illuminant C. Measurements were taken with and without filters in front of the colorimeter . Note, for the actual...to measure the chromaticity and luminance values of the different components displayed on the calibrated monitor using a spot colorimeter (Minolta CS...of Illuminant C and the chromaticity values for each of the colored squares were measured using a spot colorimeter (Minolta CS-100). Three

  6. Impact of Atmospheric Chromatic Effects on Weak Lensing Measurements

    NASA Astrophysics Data System (ADS)

    Meyers, Joshua E.; Burchat, Patricia R.

    2015-07-01

    Current and future imaging surveys will measure cosmic shear with statistical precision that demands a deeper understanding of potential systematic biases in galaxy shape measurements than has been achieved to date. We use analytic and computational techniques to study the impact on shape measurements of two atmospheric chromatic effects for ground-based surveys such as the Dark Energy Survey and the Large Synoptic Survey Telescope (LSST): (1) atmospheric differential chromatic refraction and (2) wavelength dependence of seeing. We investigate the effects of using the point-spread function (PSF) measured with stars to determine the shapes of galaxies that have different spectral energy distributions than the stars. We find that both chromatic effects lead to significant biases in galaxy shape measurements for current and future surveys, if not corrected. Using simulated galaxy images, we find a form of chromatic “model bias” that arises when fitting a galaxy image with a model that has been convolved with a stellar, instead of galactic, PSF. We show that both forms of atmospheric chromatic biases can be predicted (and corrected) with minimal model bias by applying an ordered set of perturbative PSF-level corrections based on machine-learning techniques applied to six-band photometry. Catalog-level corrections do not address the model bias. We conclude that achieving the ultimate precision for weak lensing from current and future ground-based imaging surveys requires a detailed understanding of the wavelength dependence of the PSF from the atmosphere, and from other sources such as optics and sensors. The source code for this analysis is available at https://github.com/DarkEnergyScienceCollaboration/chroma.

  7. Spectrally-balanced chromatic approach-lighting system

    NASA Technical Reports Server (NTRS)

    Chase, W. D.

    1977-01-01

    Approach lighting system employing combinations of red and blue lights reduces problem of color-based optical illusions. System exploits inherent chromatic aberration of eye to create three-dimensional effect, giving pilot visual clues of position.

  8. Chromatic energy filter and characterization of laser-accelerated proton beams for particle therapy

    NASA Astrophysics Data System (ADS)

    Hofmann, Ingo; Meyer-ter-Vehn, Jürgen; Yan, Xueqing; Al-Omari, Husam

    2012-07-01

    The application of laser accelerated protons or ions for particle therapy has to cope with relatively large energy and angular spreads as well as possibly significant random fluctuations. We suggest a method for combined focusing and energy selection, which is an effective alternative to the commonly considered dispersive energy selection by magnetic dipoles. Our method is based on the chromatic effect of a magnetic solenoid (or any other energy dependent focusing device) in combination with an aperture to select a certain energy width defined by the aperture radius. It is applied to an initial 6D phase space distribution of protons following the simulation output from a Radiation Pressure Acceleration model. Analytical formula for the selection aperture and chromatic emittance are confirmed by simulation results using the TRACEWIN code. The energy selection is supported by properly placed scattering targets to remove the imprint of the chromatic effect on the beam and to enable well-controlled and shot-to-shot reproducible energy and transverse density profiles.

  9. Anti-forensics of chromatic aberration

    NASA Astrophysics Data System (ADS)

    Mayer, Owen; Stamm, Matthew C.

    2015-03-01

    Over the past decade, a number of information forensic techniques have been developed to identify digital image manipulation and falsification. Recent research has shown, however, that an intelligent forger can use anti-forensic countermeasures to disguise their forgeries. In this paper, an anti-forensic technique is proposed to falsify the lateral chromatic aberration present in a digital image. Lateral chromatic aberration corresponds to the relative contraction or expansion between an image's color channels that occurs due to a lens's inability to focus all wavelengths of light on the same point. Previous work has used localized inconsistencies in an image's chromatic aberration to expose cut-and-paste image forgeries. The anti-forensic technique presented in this paper operates by estimating the expected lateral chromatic aberration at an image location, then removing deviations from this estimate caused by tampering or falsification. Experimental results are presented that demonstrate that our anti-forensic technique can be used to effectively disguise evidence of an image forgery.

  10. Changes in unique hues induced by chromatic surrounds.

    PubMed

    Klauke, Susanne; Wachtler, Thomas

    2016-03-01

    A chromatic surround can have a strong influence on the perceived hue of a stimulus. We investigated whether chromatic induction has similar effects on the perception of colors that appear pure and unmixed (unique red, green, blue, and yellow) as on other colors. Subjects performed unique hue settings of stimuli in isoluminant surrounds of different chromaticities. Compared with the settings in a neutral gray surround, unique hue settings altered systematically with chromatic surrounds. The amount of induced hue shift depended on the difference between stimulus and surround hues, and was similar for unique hue settings as for settings of nonunique hues. Intraindividual variability in unique hue settings was roughly twice as high as for settings obtained in asymmetric matching experiments, which may reflect the presence of a reference stimulus in the matching task. Variabilities were also larger with chromatic surrounds than with neutral gray surrounds, for both unique hue settings and matching of nonunique hues. The results suggest that the neural representations underlying unique hue percepts are influenced by the same neural processing mechanisms as the percepts of other colors.

  11. Statistical interpretation of chromatic indicators in correlation to phytochemical profile of a sulfur dioxide-free mulberry (Morus nigra) wine submitted to non-thermal maturation processes.

    PubMed

    Tchabo, William; Ma, Yongkun; Kwaw, Emmanuel; Zhang, Haining; Xiao, Lulu; Apaliya, Maurice T

    2018-01-15

    The four different methods of color measurement of wine proposed by Boulton, Giusti, Glories and Commission International de l'Eclairage (CIE) were applied to assess the statistical relationship between the phytochemical profile and chromatic characteristics of sulfur dioxide-free mulberry (Morus nigra) wine submitted to non-thermal maturation processes. The alteration in chromatic properties and phenolic composition of non-thermal aged mulberry wine were examined, aided by the used of Pearson correlation, cluster and principal component analysis. The results revealed a positive effect of non-thermal processes on phytochemical families of wines. From Pearson correlation analysis relationships between chromatic indexes and flavonols as well as anthocyanins were established. Cluster analysis highlighted similarities between Boulton and Giusti parameters, as well as Glories and CIE parameters in the assessment of chromatic properties of wines. Finally, principal component analysis was able to discriminate wines subjected to different maturation techniques on the basis of their chromatic and phenolics characteristics. Copyright © 2017. Published by Elsevier Ltd.

  12. The MOF+ Technique: A Significant Synergic Effect Enables High Performance Chromate Removal.

    PubMed

    Luo, Ming Biao; Xiong, Yang Yang; Wu, Hui Qiong; Feng, Xue Feng; Li, Jian Qiang; Luo, Feng

    2017-12-18

    A significant synergic effect between a metal-organic framework (MOF) and Fe 2 SO 4 , the so-called MOF + technique, is exploited for the first time to remove toxic chromate from aqueous solutions. The results show that relative to the pristine MOF samples (no detectable chromate removal), the MOF + method enables super performance, giving a 796 Cr mg g -1 adsorption capacity. The value is almost eight-fold higher than the best value of established MOF adsorbents, and the highest value of all reported porous adsorbents for such use. The adsorption mechanism, unlike the anion-exchange process that dominates chromate removal in all other MOF adsorbents, as unveiled by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and transmission electron microscopy (TEM), is due to the surface formation of Fe 0.75 Cr 0.25 (OH) 3 nanospheres on the MOF samples. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models.

    PubMed

    Song, Hui; Yuan, Xiaoyong; Tang, Xin

    2016-01-11

    In this study, the effects of intraocular lenses (IOLs) with different diopters (D) on chromatic aberration were investigated in human eye models, and the influences of the central thickness of IOLs on chromatic aberration were compared. A Liou-Brennan-based IOL eye model was constructed using ZEMAX optical design software. Spherical IOLs with different diopters (AR40e, AMO Company, USA) were implanted; modulation transfer function (MTF) values at 3 mm of pupil diameter and from 0 to out-of-focus blur were collected and graphed. MTF values, measured at 555 nm of monochromatic light under each spatial frequency, were significantly higher than the values measured at 470 to 650 nm of polychromatic light. The influences of chromatic aberration on MTF values decreased with the increase in IOL diopter when the spatial frequency was ≤12 c/d, while increased effects were observed when the spatial frequency was ≥15 c/d. The MTF values of each IOL eye model were significantly lower than the MTF values of the Liou-Brennan eye models when measured at 555 nm of monochromatic light and at 470 to 650 nm of polychromatic light. The MTF values were also found to be increased with the increase in IOL diopter. With higher diopters of IOLs, the central thickness increased accordingly, which could have created increased chromatic aberration and decreased the retinal image quality. To improve the postoperative visual quality, IOLs with lower chromatic aberration should be selected for patients with short axial lengths.

  14. Hue distinctiveness overrides category in determining performance in multiple object tracking.

    PubMed

    Sun, Mengdan; Zhang, Xuemin; Fan, Lingxia; Hu, Luming

    2018-02-01

    The visual distinctiveness between targets and distractors can significantly facilitate performance in multiple object tracking (MOT), in which color is a feature that has been commonly used. However, the processing of color can be more than "visual." Color is continuous in chromaticity, while it is commonly grouped into discrete categories (e.g., red, green). Evidence from color perception suggested that color categories may have a unique role in visual tasks independent of its chromatic appearance. Previous MOT studies have not examined the effect of chromatic and categorical distinctiveness on tracking separately. The current study aimed to reveal how chromatic (hue) and categorical distinctiveness of color between the targets and distractors affects tracking performance. With four experiments, we showed that tracking performance was largely facilitated by the increasing hue distance between the target set and the distractor set, suggesting that perceptual grouping was formed based on hue distinctiveness to aid tracking. However, we found no color categorical effect, because tracking performance was not significantly different when the targets and distractors were from the same or different categories. It was concluded that the chromatic distinctiveness of color overrides category in determining tracking performance, suggesting a dominant role of perceptual feature in MOT.

  15. When Do Short-Wave Cones Signal Blue or Red? A Solution Introducing the Concept of Primary and Secondary Cone Outputs

    PubMed Central

    2016-01-01

    A recent paper by Oh and Sakata investigates the “incompletely solved mystery” of how the three cone responses map onto perceived hue, and particularly the S cone’s well-known problematic contribution to blueness and redness. Citing previous workers, they argue the twentieth century traditional multistage model does not satisfactorily account for color appearance. In their experiment, increasing S cone excitation with shortening wavelength from about 480–460 nm increased perceived blueness up to the unique Blue point at 470 nm, when (a) it began decreasing and (b) redness perception began increasing. The authors asked, What mechanism can be responsible for such functions? I demonstrate a solution. First, it is shown the problem does not lie in the traditional opponent color chromatic responses yellow-blue, red-green (y-b, r-g, which accurately predict the above functions), but in the traditional multistage model of mapping cone responses to chromatic response functions. Arguably, this is due to the S cone’s hypothetically signaling both blueness and redness by the same mechanism rather than by different, independent, mechanisms. Hence a new distinction or mechanism is proposed for a more accurate model, that introduces the new terms primary and secondary cone outputs. However, this distinction requires that the cones S, M, L each directly produce one of the three spectral chromatic responses b, g, y. Such a model was recently published, based on extremely high correlation of SML cone responsivities with the three spectral (bgy) chromatic responses. This model encodes the former directly onto the latter one-to-one as cone primary outputs, whilst S and L cones have a further or secondary function where each produces one of the two spectral lobes of r chromatic response. The proposed distinction between primary and secondary cone outputs is a new concept and useful tool in detailing cone outputs to chromatic channels, and provides a solution to the above “incompletely solved mystery.” Thus the S cone has a primary output producing the total b chromatic response and a secondary output that shares with the L cone the production of r chromatic response, thus aligning with Oh and Sokata’s results. The model similarly maps L cone to yellowness as primary output and to redness as secondary output. PMID:27110938

  16. Chromatic aberration correction: an enhancement to the calibration of low-cost digital dermoscopes.

    PubMed

    Wighton, Paul; Lee, Tim K; Lui, Harvey; McLean, David; Atkins, M Stella

    2011-08-01

    We present a method for calibrating low-cost digital dermoscopes that corrects for color and inconsistent lighting and also corrects for chromatic aberration. Chromatic aberration is a form of radial distortion that often occurs in inexpensive digital dermoscopes and creates red and blue halo-like effects on edges. Being radial in nature, distortions due to chromatic aberration are not constant across the image, but rather vary in both magnitude and direction. As a result, distortions are not only visually distracting but could also mislead automated characterization techniques. Two low-cost dermoscopes, based on different consumer-grade cameras, were tested. Color is corrected by imaging a reference and applying singular value decomposition to determine the transformation required to ensure accurate color reproduction. Lighting is corrected by imaging a uniform surface and creating lighting correction maps. Chromatic aberration is corrected using a second-order radial distortion model. Our results for color and lighting calibration are consistent with previously published results, while distortions due to chromatic aberration can be reduced by 42-47% in the two systems considered. The disadvantages of inexpensive dermoscopy can be quickly substantially mitigated with a suitable calibration procedure. © 2011 John Wiley & Sons A/S.

  17. Molybdate Coatings for Protecting Aluminum Against Corrosion

    NASA Technical Reports Server (NTRS)

    Calle, Luz Marina; MacDowell, Louis G.

    2005-01-01

    Conversion coatings that comprise mixtures of molybdates and several additives have been subjected to a variety of tests to evaluate their effectiveness in protecting aluminum and alloys of aluminum against corrosion. Molybdate conversion coatings are under consideration as replacements for chromate conversion coatings, which have been used for more than 70 years. The chromate coatings are highly effective in protecting aluminum and its alloys against corrosion but are also toxic and carcinogenic. Hexavalent molybdenum and, hence, molybdates containing hexavalent molybdenum, have received attention recently as replacements for chromates because molybdates mimic chromates in a variety of applications but exhibit significantly lower toxicity. The tests were performed on six proprietary formulations of molybdate conversion coatings, denoted formulations A through F, on panels of aluminum alloy 2024-T3. A bare alloy panel was also included in the tests. The tests included electrochemical impedance spectroscopy (EIS), measurements of corrosion potentials, scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS), and x-ray photoelectron spectroscopy (XPS).

  18. LLR data analysis and impact on lunar dynamics from recent developments at OCA LLR Station

    NASA Astrophysics Data System (ADS)

    Viswanathan, Vishnu; Fienga, Agnes; Courde, Clement; Torre, Jean-Marie; Exertier, Pierre; Samain, Etienne; Feraudy, Dominique; Albanese, Dominique; Aimar, Mourad; Mariey, Hervé; Viot, Hervé; Martinot-Lagarde, Gregoire

    2016-04-01

    Since late 2014, OCA LLR station has been able to range with infrared wavelength (1064nm). IR ranging provides both temporal and spatial improvement in the LLR observations. IR detection also permits in densification of normal points, including the L1 and L2 retroreflectors due to better signal to noise ratio. This contributes to a better modelisation of the lunar libration. The hypothesis of lunar dust and environmental effects due to the chromatic behavior noticed on returns from L2 retroreflector is discussed. In addition, data analysis shows that the effect of retroreflector tilt and the use of calibration profile for the normal point deduction algorithm, contributes to improving the precision of normal points, thereby impacting lunar dynamical models and inner physics.

  19. Corrosion-resistant uranium

    DOEpatents

    Hovis, V.M. Jr.; Pullen, W.C.; Kollie, T.G.; Bell, R.T.

    1981-10-21

    The present invention is directed to the protecting of uranium and uranium alloy articles from corrosion by providing the surfaces of the articles with a layer of an ion-plated metal selected from aluminum and zinc to a thickness of at least 60 microinches and then converting at least the outer surface of the ion-plated layer of aluminum or zinc to aluminum chromate or zinc chromate. This conversion of the aluminum or zinc to the chromate form considerably enhances the corrosion resistance of the ion plating so as to effectively protect the coated article from corrosion.

  20. Corrosion-resistant uranium

    DOEpatents

    Hovis, Jr., Victor M.; Pullen, William C.; Kollie, Thomas G.; Bell, Richard T.

    1983-01-01

    The present invention is directed to the protecting of uranium and uranium alloy articles from corrosion by providing the surfaces of the articles with a layer of an ion-plated metal selected from aluminum and zinc to a thickness of at least 60 microinches and then converting at least the outer surface of the ion-plated layer of aluminum or zinc to aluminum chromate or zinc chromate. This conversion of the aluminum or zinc to the chromate form considerably enhances the corrosion resistance of the ion plating so as to effectively protect the coated article from corrosion.

  1. Chromatic refraction with global ozone monitoring by occultation of stars. I. Description and scintillation correction.

    PubMed

    Dalaudier, F; Kan, V; Gurvich, A S

    2001-02-20

    We describe refractive and chromatic effects, both regular and random, that occur during star occultations by the Earth's atmosphere. The scintillation that results from random density fluctuations, as well as the consequences of regular chromatic refraction, is qualitatively described. The resultant chromatic scintillation will produce random features on the Global Ozone Monitoring by Occultation of Stars (GOMOS) spectrometer, with an amplitude comparable with that of some of the real absorbing features that result from atmospheric constituents. A correction method that is based on the use of fast photometer signals is described, and its efficiency is discussed. We give a qualitative (although accurate) description of the phenomena, including numerical values when needed. Geometrical optics and the phase-screen approximation are used to keep the description simple.

  2. Experimental verification of the minimum number of diffractive zones for effective chromatic correction in the LWIR

    NASA Astrophysics Data System (ADS)

    Ramsey, J. L.; Walsh, K. F.; Smith, M.; Deegan, J.

    2016-05-01

    With the move to smaller pixel sizes in the longwave IR region there has been a push for shorter focal length lenses that are smaller, cheaper and lighter and that resolve lower spatial frequencies. As a result lenses must have better correction for both chromatic and monochromatic aberrations. This leads to the increased use of aspheres and diffractive optical elements (kinoforms). With recent developments in the molding of chalcogenide materials these aspheres and kinoforms are more cost effective to manufacture. Without kinoforms the axial color can be on the order of 15 μm which degrades the performance of the lens at the Nyquist frequency. The kinoforms are now on smaller elements and are correcting chromatic aberration which is on the order of the design wavelength. This leads to kinoform structures that do not require large phase changes and therefore have 1.5 to just over 2 zones. The question becomes how many zones are required to correct small amounts of chromatic aberration in the system and are they functioning as predicted by the lens design software? We investigate both the design performance and the as-built performance of two designs that incorporate kinoforms for the correction of axial chromatic aberration.

  3. Assessment of the Environmental Effects Associated With Wooden Bridges Preserved With Creosote, Pentachlorophenol, or Chromated Copper Arsenate

    DOT National Transportation Integrated Search

    2000-09-01

    Timber bridge components are treated with chromated copper arsenate type C (CCA), pentachlorophenol or creosote to preserve the life of the structure from a few years to many decades, resulting in reduced transportation infrastructure costs and incre...

  4. Effects of visual attention on chromatic and achromatic detection sensitivities.

    PubMed

    Uchikawa, Keiji; Sato, Masayuki; Kuwamura, Keiko

    2014-05-01

    Visual attention has a significant effect on various visual functions, such as response time, detection and discrimination sensitivity, and color appearance. It has been suggested that visual attention may affect visual functions in the early visual pathways. In this study we examined selective effects of visual attention on sensitivities of the chromatic and achromatic pathways to clarify whether visual attention modifies responses in the early visual system. We used a dual task paradigm in which the observer detected a peripheral test stimulus presented at 4 deg eccentricities while the observer concurrently carried out an attention task in the central visual field. In experiment 1, it was confirmed that peripheral spectral sensitivities were reduced more for short and long wavelengths than for middle wavelengths with the central attention task so that the spectral sensitivity function changed its shape by visual attention. This indicated that visual attention affected the chromatic response more strongly than the achromatic response. In experiment 2 it was obtained that the detection thresholds increased in greater degrees in the red-green and yellow-blue chromatic directions than in the white-black achromatic direction in the dual task condition. In experiment 3 we showed that the peripheral threshold elevations depended on the combination of color-directions of the central and peripheral stimuli. Since the chromatic and achromatic responses were separately processed in the early visual pathways, the present results provided additional evidence that visual attention affects responses in the early visual pathways.

  5. Assessment of Rod, Cone, and Intrinsically Photosensitive Retinal Ganglion Cell Contributions to the Canine Chromatic Pupillary Response.

    PubMed

    Yeh, Connie Y; Koehl, Kristin L; Harman, Christine D; Iwabe, Simone; Guzman, José M; Petersen-Jones, Simon M; Kardon, Randy H; Komáromy, András M

    2017-01-01

    The purpose of this study was to evaluate a chromatic pupillometry protocol for specific functional assessment of rods, cones, and intrinsically photosensitive retinal ganglion cells (ipRGCs) in dogs. Chromatic pupillometry was tested and compared in 37 dogs in different stages of primary loss of rod, cone, and combined rod/cone and optic nerve function, and in 5 wild-type (WT) dogs. Eyes were stimulated with 1-s flashes of dim (1 cd/m2) and bright (400 cd/m2) blue light (for scotopic conditions) or bright red (400 cd/m2) light with 25-cd/m2 blue background (for photopic conditions). Canine retinal melanopsin/Opn4 was cloned, and its expression was evaluated using real-time quantitative reverse transcription-PCR and immunohistochemistry. Mean ± SD percentage of pupil constriction amplitudes induced by scotopic dim blue (scDB), scotopic bright blue (scBB), and photopic bright red (phBR) lights in WT dogs were 21.3% ± 10.6%, 50.0% ± 17.5%, and 19.4% ± 7.4%, respectively. Melanopsin-mediated responses to scBB persisted for several minutes (7.7 ± 4.6 min) after stimulus offset. In dogs with inherited retinal degeneration, loss of rod function resulted in absent scDB responses, followed by decreased phBR responses with disease progression and loss of cone function. Primary loss of cone function abolished phBR responses but preserved those responses to blue light (scDB and scBB). Although melanopsin/Opn4 expression was diminished with retinal degeneration, melanopsin-expressing ipRGCs were identified for the first time in both WT and degenerated canine retinas. Pupil responses elicited by light stimuli of different colors and intensities allowed differential functional assessment of canine rods, cones, and ipRGCs. Chromatic pupillometry offers an effective tool for diagnosing retinal and optic nerve diseases.

  6. The Representation of Color across the Human Visual Cortex: Distinguishing Chromatic Signals Contributing to Object Form Versus Surface Color.

    PubMed

    Seymour, K J; Williams, M A; Rich, A N

    2016-05-01

    Many theories of visual object perception assume the visual system initially extracts borders between objects and their background and then "fills in" color to the resulting object surfaces. We investigated the transformation of chromatic signals across the human ventral visual stream, with particular interest in distinguishing representations of object surface color from representations of chromatic signals reflecting the retinal input. We used fMRI to measure brain activity while participants viewed figure-ground stimuli that differed either in the position or in the color contrast polarity of the foreground object (the figure). Multivariate pattern analysis revealed that classifiers were able to decode information about which color was presented at a particular retinal location from early visual areas, whereas regions further along the ventral stream exhibited biases for representing color as part of an object's surface, irrespective of its position on the retina. Additional analyses showed that although activity in V2 contained strong chromatic contrast information to support the early parsing of objects within a visual scene, activity in this area also signaled information about object surface color. These findings are consistent with the view that mechanisms underlying scene segmentation and the binding of color to object surfaces converge in V2. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Chromatic diversity: a new approach for characterizing spatiotemporal coupling of ultrashort pulses.

    PubMed

    Bahk, Seung-Whan; Dorrer, Christophe; Bromage, Jake

    2018-04-02

    Two-dimensional chromatic aberrations are characterized by a single-shot scheme based on a simultaneous measurement of chromatically diversified focal spots. The chromatic diversity is introduced by a 2-D grating with holographic defocus terms. The chromatic aberrations in the beam are either subtracted or added by the additional known chromatic aberrations in the grating, depending on the diffraction order. By analyzing the asymmetry in the size of diffracted focal spots, input beam chromatic aberrations can be deduced. Theoretical discussions and experimental results are presented.

  8. Chromatic diversity: a new approach for characterizing spatiotemporal coupling of ultrashort pulses

    DOE PAGES

    Bahk, Seung-Whan; Dorrer, Christophe; Bromage, Jake

    2018-01-01

    Two-dimensional chromatic aberrations are characterized by a single-shot scheme based on a simultaneous measurement of chromatically diversified focal spots. The chromatic diversity is introduced by a 2-D grating with holographic defocus terms. The chromatic aberrations in the beam are either subtracted or added by the additional known chromatic aberrations in the grating, depending on the diffraction order. By analyzing the asymmetry in the size of diffracted focal spots, input beam chromatic aberrations can be deduced. Theoretical discussions and experimental results are also presented.

  9. [Lateral chromatic aberrations correction for AOTF imaging spectrometer based on doublet prism].

    PubMed

    Zhao, Hui-Jie; Zhou, Peng-Wei; Zhang, Ying; Li, Chong-Chong

    2013-10-01

    An user defined surface function method was proposed to model the acousto-optic interaction of AOTF based on wave-vector match principle. Assessment experiment result shows that this model can achieve accurate ray trace of AOTF diffracted beam. In addition, AOTF imaging spectrometer presents large residual lateral color when traditional chromatic aberrations correcting method is adopted. In order to reduce lateral chromatic aberrations, a method based on doublet prism is proposed. The optical material and angle of the prism are optimized automatically using global optimization with the help of user defined AOTF surface. Simulation result shows that the proposed method provides AOTF imaging spectrometer with great conveniences, which reduces the lateral chromatic aberration to less than 0.000 3 degrees and improves by one order of magnitude, with spectral image shift effectively corrected.

  10. Kinetics of chromate reduction during naphthalene degradation in a mixed culture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, H.; Sewell, G.W.; Pritchard, P.H.

    A mixed culture of Bacillus sp. K1 and Sphingomonas paucimobilis EPA 505 was exposed to chromate and naphthalene. Batch experiments showed that chromate was reduced and naphthalene was degraded by the mixed culture. Chromate reduction occurred initially at a high rate followed by a decrease in rate until chromate reduction ceased. Chromate reduction decreased in the mixed culture when a lower ratio of S. paucimobilis EPA 505 to Bacillus sp. K1 was utilized. A kinetic model incorporating a term for the cell density ratio is proposed to describe chromate reduction in the mixed culture under both chromate limited and electronmore » donor limited conditions. The validity of the model, and its parameter values, was verified by experimental data generated under a variety of initial population compositions and a broad range of chromate concentrations. The consistent result of experimental data with model predictions implies that the model is useful for evaluating the interactions and the use of mixed culture for chromate removal.« less

  11. Contrast gain control: a bilinear model for chromatic selectivity.

    PubMed

    Singer, B; D'Zmura, M

    1995-04-01

    We report the results of psychophysical experiments on color contrast induction. In earlier work [Vision Res. 34, 3111 (1994)], we showed that modulating the spatial contrast of an annulus in time induces an apparent modulation of the contrast of a central disk, at isoluminance. Here we vary the chromatic properties of disk and annulus systematically in a study of the interactions among the luminance and the color-opponent channels. Results show that induced contrast depends linearly on both disk and annulus contrast, at low and moderate contrast levels. This dependence leads us to propose a bilinear model for color contrast gain control. The model predicts the magnitude and the chromatic properties of induced contrast. In agreement with experimental results, the model displays chromatic selectivity in contrast gain control and a negligible effect of contrast modulation at isoluminance on the appearance of achromatic contrast. We show that the bilinear model for chromatic selectivity may be realized as a feed-forward multiplicative gain control. Data collected at high contrast levels are fit by embellishing the model with saturating nonlinearities in the contrast gain control of each color channel.

  12. COMPARISON OF NONLINEAR DYNAMICS OPTIMIZATION METHODS FOR APS-U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Y.; Borland, Michael

    Many different objectives and genetic algorithms have been proposed for storage ring nonlinear dynamics performance optimization. These optimization objectives include nonlinear chromaticities and driving/detuning terms, on-momentum and off-momentum dynamic acceptance, chromatic detuning, local momentum acceptance, variation of transverse invariant, Touschek lifetime, etc. In this paper, the effectiveness of several different optimization methods and objectives are compared for the nonlinear beam dynamics optimization of the Advanced Photon Source upgrade (APS-U) lattice. The optimized solutions from these different methods are preliminarily compared in terms of the dynamic acceptance, local momentum acceptance, chromatic detuning, and other performance measures.

  13. Focusing Intense Charged Particle Beams with Achromatic Effects for Heavy Ion Fusion

    NASA Astrophysics Data System (ADS)

    Mitrani, James; Kaganovich, Igor

    2012-10-01

    Final focusing systems designed to minimize the effects of chromatic aberrations in the Neutralized Drift Compression Experiment (NDCX-II) are described. NDCX-II is a linear induction accelerator, designed to accelerate short bunches at high current. Previous experiments showed that neutralized drift compression significantly compresses the beam longitudinally (˜60x) in the z-direction, resulting in a narrow distribution in z-space, but a wide distribution in pz-space. Using simple lenses (e.g., solenoids, quadrupoles) to focus beam bunches with wide distributions in pz-space results in chromatic aberrations, leading to lower beam intensities (J/cm^2). Therefore, the final focusing system must be designed to compensate for chromatic aberrations. The paraxial ray equations and beam envelope equations are numerically solved for parameters appropriate to NDCX-II. Based on these results, conceptual designs for final focusing systems using a combination of solenoids and/or quadrupoles are optimized to compensate for chromatic aberrations. Lens aberrations and emittance growth will be investigated, and analytical results will be compared with results from numerical particle-in-cell (PIC) simulation codes.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bahk, Seung-Whan; Dorrer, Christophe; Bromage, Jake

    Two-dimensional chromatic aberrations are characterized by a single-shot scheme based on a simultaneous measurement of chromatically diversified focal spots. The chromatic diversity is introduced by a 2-D grating with holographic defocus terms. The chromatic aberrations in the beam are either subtracted or added by the additional known chromatic aberrations in the grating, depending on the diffraction order. By analyzing the asymmetry in the size of diffracted focal spots, input beam chromatic aberrations can be deduced. Theoretical discussions and experimental results are also presented.

  15. The effects of longitudinal chromatic aberration and a shift in the peak of the middle-wavelength sensitive cone fundamental on cone contrast

    PubMed Central

    Rucker, F. J.; Osorio, D.

    2009-01-01

    Longitudinal chromatic aberration is a well-known imperfection of visual optics, but the consequences in natural conditions, and for the evolution of receptor spectral sensitivities are less well understood. This paper examines how chromatic aberration affects image quality in the middle-wavelength sensitive (M-) cones, viewing broad-band spectra, over a range of spatial frequencies and focal planes. We also model the effects on M-cone contrast of moving the M-cone fundamental relative to the long- and middle-wavelength (L- and M-cone) fundamentals, while the eye is accommodated at different focal planes or at a focal plane that maximizes luminance contrast. When the focal plane shifts towards longer (650 nm) or shorter wavelengths (420 nm) the effects on M-cone contrast are large: longitudinal chromatic aberration causes total loss of M-cone contrast above 10 to 20 c/d. In comparison, the shift of the M-cone fundamental causes smaller effects on M-cone contrast. At 10 c/d a shift in the peak of the M-cone spectrum from 560 nm to 460 nm decreases M-cone contrast by 30%, while a 10 nm blue-shift causes only a minor loss of contrast. However, a noticeable loss of contrast may be seen if the eye is focused at focal planes other than that which maximizes luminance contrast. The presence of separate long- and middle-wavelength sensitive cones therefore has a small, but not insignificant cost to the retinal image via longitudinal chromatic aberration. This aberration may therefore be a factor limiting evolution of visual pigments and trichromatic color vision. PMID:18639571

  16. Comparative study on liquefaction of creosote and chromated copper arsenate (CCA)-treated wood and untreated southern pine wood: effects of acid catalyst content, liquefaction time, temperature, and phenol to wood ratio

    Treesearch

    Hui Pan; Chung-Yun Hse; Todd F. Shupe

    2009-01-01

    Creosote- and chromated copper arsenate (CCA)-treated wood waste and untreated southern pine wood were liquefied with phenol and sulfuric acid. The effects of sulfuric acid content, liquefaction time, liquefaction temperature, and phenol to wood ratio on liquefaction rate (i.e., wood residue content) were investigated and analyzed by analysis of variance (...

  17. Estimation of errors in luminance signals encoded by primate retina resulting from sampling of natural images with red and green cones.

    PubMed

    Osorio, D; Ruderman, D L; Cronin, T W

    1998-01-01

    Both long-wavelength-sensitive (L) and medium-wavelength-sensitive (M) cones contribute to luminance mechanisms in human vision. This means that luminance and chromatic signals may be confounded. We use power spectra from natural images to estimate the magnitude of the corruption of luminance signals encoded by an array of retinal ganglion cells resembling the primate magnocellular neurons. The magnitude of this corruption is dependent on the cone lattice and is most severe where cones form clumps of a single spectral type. We find that chromatic corruption may equal or exceed the amplitude of other sources of noise and so could impose constraints on visual performance and on eye design.

  18. Electrocortical amplification for emotionally arousing natural scenes: The contribution of luminance and chromatic visual channels

    PubMed Central

    Miskovic, Vladimir; Martinovic, Jasna; Wieser, Matthias M.; Petro, Nathan M.; Bradley, Margaret M.; Keil, Andreas

    2015-01-01

    Emotionally arousing scenes readily capture visual attention, prompting amplified neural activity in sensory regions of the brain. The physical stimulus features and related information channels in the human visual system that contribute to this modulation, however, are not known. Here, we manipulated low-level physical parameters of complex scenes varying in hedonic valence and emotional arousal in order to target the relative contributions of luminance based versus chromatic visual channels to emotional perception. Stimulus-evoked brain electrical activity was measured during picture viewing and used to quantify neural responses sensitive to lower-tier visual cortical involvement (steady-state visual evoked potentials) as well as the late positive potential, reflecting a more distributed cortical event. Results showed that the enhancement for emotional content was stimulus-selective when examining the steady-state segments of the evoked visual potentials. Response amplification was present only for low spatial frequency, grayscale stimuli, and not for high spatial frequency, red/green stimuli. In contrast, the late positive potential was modulated by emotion regardless of the scene’s physical properties. Our findings are discussed in relation to neurophysiologically plausible constraints operating at distinct stages of the cortical processing stream. PMID:25640949

  19. Electrocortical amplification for emotionally arousing natural scenes: the contribution of luminance and chromatic visual channels.

    PubMed

    Miskovic, Vladimir; Martinovic, Jasna; Wieser, Matthias J; Petro, Nathan M; Bradley, Margaret M; Keil, Andreas

    2015-03-01

    Emotionally arousing scenes readily capture visual attention, prompting amplified neural activity in sensory regions of the brain. The physical stimulus features and related information channels in the human visual system that contribute to this modulation, however, are not known. Here, we manipulated low-level physical parameters of complex scenes varying in hedonic valence and emotional arousal in order to target the relative contributions of luminance based versus chromatic visual channels to emotional perception. Stimulus-evoked brain electrical activity was measured during picture viewing and used to quantify neural responses sensitive to lower-tier visual cortical involvement (steady-state visual evoked potentials) as well as the late positive potential, reflecting a more distributed cortical event. Results showed that the enhancement for emotional content was stimulus-selective when examining the steady-state segments of the evoked visual potentials. Response amplification was present only for low spatial frequency, grayscale stimuli, and not for high spatial frequency, red/green stimuli. In contrast, the late positive potential was modulated by emotion regardless of the scene's physical properties. Our findings are discussed in relation to neurophysiologically plausible constraints operating at distinct stages of the cortical processing stream. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Ultrasound-assisted synthesis of zinc molybdate nanocrystals and molybdate-doped epoxy/PDMS nanocomposite coatings for Mg alloy protection.

    PubMed

    Eduok, Ubong; Szpunar, Jerzy

    2018-06-01

    Zinc molybdate (ZM) is a safer anticorrosive additive for cooling systems when compared with chromates and lead salts, due to its insolubility in aqueous media. For most molybdate pigments, their molybdate anion (MoO 4 -2 ) acts as an anionic inhibitor and its passivation capacity is comparable with chromate anion (CrO 4 -2 ). To alleviate the environmental concerns involving chromates-based industrial protective coatings, we have proposed new alternative in this work. We have synthesized ZM nanocrystals via ultrasound-assisted process and encapsulated them within an epoxy/PDMS coating towards corrosion protection. The surface morphology and mechanical properties of these ZM doped epoxy/PDMS nanocomposite coatings is exhaustively discussed to show the effect of ZM content on protective properties. The presence of ZM nanocrystals significantly contributed to the corrosion barrier performance of the coating while the amount of ZM nanocrystals needed to prepare an epoxy coating with optimum barrier performance was established. Beyond 2 wt% ZM concentration, the siloxane-structured epoxy coating network became saturated with ZM pigments. This further broadened inherent pores channels, leading to the percolation of corrosion chloride ions through the coating. SEM evidence has revealed proof of surface delamination on ZM3 coating. A model mechanism of corrosion resistance has been proposed for ZM doped epoxy/PDMS nanocomposite coatings from exhaustive surface morphological investigations and evidence. This coating matrix may have emerging applications in cooling systems as anticorrosive surface paints as well as create an avenue for environmental corrosion remediation. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of zinc and chromate in cooling water by differential pulse polarography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jindal, V.K.; Kham, M.A.; Bhatnagar, R.M.

    1985-01-01

    The use of differential pulse polarography (DPP) for the simultaneous determination of zinc and chromate in cooling water is reported where zinc (5 ppm), chromate (20 ppm), and polyphosphate (50 ppm) formulation is used as a corrosion inhibitor. This will help in effective control of cooling tower performance. The DPP method has been applied for the simultaneous determination of zinc and chromate ions in process and cooling water samples from fertilizer plants in India. The method is based on the reduction of Cr and Zn on SMDE in 1 M NH3-0.1 M NH/sub 4/Cl and 0.005% gelatine supporting electrolyte. Duemore » to interference it is essential to complex calcium ions by adding polyphosphate and to destroy NO/sub 2//sup -//NO/sub 3//sup -/ by adding sulfamic acid along with hydrochloric acid before the actual recording of DP polarograms. The present DP polarographic method for the simultaneous determination of zinc and chromate is comparable in its utility and applicability with spectrophotometric methods. The method has a better accuracy and higher sensitivity and is quick, as both of the ions can be determined in a single scan. 10 references, 4 figures, 5 tables.« less

  2. Three-dimensional shape perception from chromatic orientation flows

    PubMed Central

    Zaidi, Qasim; Li, Andrea

    2010-01-01

    The role of chromatic information in 3-D shape perception is controversial. We resolve this controversy by showing that chromatic orientation flows are sufficient for accurate perception of 3-D shape. Chromatic flows required less cone contrast to convey shape than did achromatic flows, thus ruling out luminance artifacts as a problem. Luminance artifacts were also ruled out by a protanope’s inability to see 3-D shape from chromatic flows. Since chromatic orientation flows can only be extracted from retinal images by neurons that are responsive to color modulations and selective for orientation, the psychophysical results also resolve the controversy over the existence of such neurons. In addition, we show that identification of 3-D shapes from chromatic flows can be masked by luminance modulations, indicating that it is subserved by orientation-tuned neurons sensitive to both chromatic and luminance modulations. PMID:16961963

  3. Neurophysiological Evidence for Categorical Perception of Color

    ERIC Educational Resources Information Center

    Holmes, Amanda; Franklin, Anna; Clifford, Alexandra; Davies, Ian

    2009-01-01

    The aim of this investigation was to examine the time course and the relative contributions of perceptual and post-perceptual processes to categorical perception (CP) of color. A visual oddball task was used with standard and deviant stimuli from same (within-category) or different (between-category) categories, with chromatic separations for…

  4. UHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology

    PubMed Central

    Wang, Xiaohua; Li, Xi; Rong, Mingzhe; Xie, Dingli; Ding, Dan; Wang, Zhixiang

    2017-01-01

    The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in color science are introduced. The chromatic processing represents UHF signals sparsely. The UHF signals obtained from PD experiments were processed using chromatic methodology and characterized by three parameters in chromatic space (H, L, and S representing dominant wavelength, signal strength, and saturation, respectively). The features of the UHF signals were studied hierarchically. The results showed that the chromatic parameters were consistent with conventional frequency domain parameters. The global chromatic parameters can be used to distinguish UHF signals acquired by different sensors, and they reveal the propagation properties of the UHF signal in the L-shaped gas-insulated switchgear (GIS). Finally, typical PD defect patterns had been recognized by using novel chromatic parameters in an actual GIS tank and good performance of recognition was achieved. PMID:28106806

  5. UHF Signal Processing and Pattern Recognition of Partial Discharge in Gas-Insulated Switchgear Using Chromatic Methodology.

    PubMed

    Wang, Xiaohua; Li, Xi; Rong, Mingzhe; Xie, Dingli; Ding, Dan; Wang, Zhixiang

    2017-01-18

    The ultra-high frequency (UHF) method is widely used in insulation condition assessment. However, UHF signal processing algorithms are complicated and the size of the result is large, which hinders extracting features and recognizing partial discharge (PD) patterns. This article investigated the chromatic methodology that is novel in PD detection. The principle of chromatic methodologies in color science are introduced. The chromatic processing represents UHF signals sparsely. The UHF signals obtained from PD experiments were processed using chromatic methodology and characterized by three parameters in chromatic space ( H , L , and S representing dominant wavelength, signal strength, and saturation, respectively). The features of the UHF signals were studied hierarchically. The results showed that the chromatic parameters were consistent with conventional frequency domain parameters. The global chromatic parameters can be used to distinguish UHF signals acquired by different sensors, and they reveal the propagation properties of the UHF signal in the L-shaped gas-insulated switchgear (GIS). Finally, typical PD defect patterns had been recognized by using novel chromatic parameters in an actual GIS tank and good performance of recognition was achieved.

  6. Removal characteristics of anionic metals by micellar-enhanced ultrafiltration.

    PubMed

    Baek, Kitae; Kim, Bo-Kyong; Cho, Hyun-Jeong; Yang, Ji-Won

    2003-05-30

    Surfactant-based separation of Fe(CN)(6)(3-) and CrO(4)(2-) using regenerated cellulose membrane was studied in order to assess the potential of micellar-enhanced ultrafiltration for the remediation of wastewater or groundwater polluted with ferriccyanide and chromate. In the ferriccyanide/octadecylamine acetate (ODA) and chromate/ODA systems, removal of ferriccyanide increased from 73 to 92% and to 98%, and that of chromate from 64 to 97% and to >99.9% as the molar ratio of ODA to ferriccyanide and to chromate increased from 1 to 2 and to 3, respectively. In the ferriccyanide/chromate/ODA system, while the removal of ferriccyanide increased from 62 to 72% and to 93%, the removal of chromate from 20 to 38% and to 68% as the molar ratio of ferriccyanide:chromate:ODA increased from 1:1:1 to 1:1:2 and to 1:1:4, respectively. With the molar ratio of 1:1:6, the removal was >99.9 and 98% for chromate and ferriccyanide, respectively. Ferriccyanide ions were more easily bound to ODA micelles because the binding power of ferriccyanide was greater than that of chromate.

  7. Rapid microwave-assisted acid extraction of metals from chromated copper arsenate (CCA)-treated southern pine wood

    Treesearch

    Bin Yu; Chung Y. Hse; Todd F. Shupe

    2009-01-01

    The effects of acid concentration, reaction time, and temperature in a microwave reactor on recovery of CCA-treated wood were evaluated. Extraction of copper, chromium, and arsenic metals from chromated copper arsenate (CCA)-treated southern pine wood samples with three different acids (i.e., acetic acid, oxalic acid, and phosphoric acid) was investigated using in...

  8. Photon Sieve Bandwidth Broadening by Reduction of Chromatic Aberration Effects Using Second-Stage Diffractive Optics

    DTIC Science & Technology

    2015-03-26

    A photon sieve is a lightweight diffractive optic which can be useful for space - based imaging applications. It is limited by chromatic...would also like to thank my sponsor, Dr. Matthew G. McHarg from the Space Physics and Atmospheric Research Center, United States Air Force Academy, as...Page 21. Radial Hole Spacing

  9. Microwave-assisted organic acids extraction of chromate copper arsenate (CCA)-treated southern pine

    Treesearch

    Bin Yu; Chung Y. Hse; Todd F. Shupe

    2010-01-01

    The extraction effects of acid concentration, reaction time and temperature in a microwave reactor on recovery of CCA-treated wood were evaluated. Extraction of copper, chromium, and arsenic metals from chromated copper arsenate (CCA)-treated southern pine wood samples with two different organic acids (i.e., acetic acid and oxalic acid) was investigated using a...

  10. Ultrafiltration membrane for effective removal of chromium ions from potable water

    NASA Astrophysics Data System (ADS)

    Muthumareeswaran, M. R.; Alhoshan, Mansour; Agarwal, Gopal Prasad

    2017-01-01

    The objective of the present work was to investigate the efficacy of indigenously developed polyacrylonitrile (PAN) based ultrafiltration (UF) membrane for chromium ions removal from potable water. The hydrolyzed PAN membranes effectively rejected chromium anions in the feed ranging from 250 ppb to 400 ppm and a rejection of ≥90% was achieved for pH ≥ 7 at low chromate concentration (≤25 ppm) in feed. The rejection mechanism of chromium ions was strongly dependent on Donnan exclusion principle, while size exclusion principle for UF did not play a major role on ions rejection. Feed pH played a vital role in changing porosity of membrane, which influenced the retention behavior of chromate ions. Cross-flow velocity, pressure did not play significant role for ions rejection at low feed concentration. However, at higher feed concentration (≥400 ppm), concentration polarization became important and it reduced the chromate rejection to 32% at low cross flow and high pressure. Donnan steric-partitioning pore and dielectric exclusion model (DSPM-DE) was applied to evaluate the chromate ions transport through PAN UF membrane as a function of flux by using optimized model parameters and the simulated data matched well with experimental results.

  11. Ultrasonic assisted rapid synthesis of high uniform super-paramagnetic microspheres with core-shell structure and robust magneto-chromatic ability

    NASA Astrophysics Data System (ADS)

    Zhang, Wenyan; Chen, Jiahua; Wang, Wei; Lu, GongXuan; Hao, Lingyun; Ni, Yaru; Lu, Chunhua; Xu, Zhongzi

    2017-03-01

    Super-paramagnetic core-shell microspheres were synthesized by ultrasonic assisted routine under low ultrasonic irradiation powers. Compared with conventional routine, ultrasonic effect could not only improve the uniformity of the core-shell structure of Fe3O4@SiO2, but shorten the synthesis time in large scale. Owing to their hydrophilicity and high surface charge, the Fe3O4@SiO2 microspheres could be dispersed well in distilled water to form homogeneous colloidal suspension. The suspensions have favorable magneto-chromatic ability that they sensitively exhibit brilliant colorful ribbons by magnetic attraction. The colorful ribbons, which distributed along the magnetic lines, make morphology of the magnetic fields become "visible" to naked eyed. Those colorful ribbons originate from strong magnetic interaction between the microspheres and magnetic fields. Furthermore, the magneto-chromatic performance is reversible as the colorful ribbons vanished rapidly with the removing of magnetic fields. The silica layer effectively enhanced the acid resistance and surface-oxidation resistance of theFe3O4@SiO2 microspheres, so they could exhibit stable magnetic nature and robust magneto-chromatic property in acid environment.

  12. Influences of wide-angle and multi-beam interference on the chromaticity and efficiency of top-emitting white organic light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Deng, Lingling; Zhou, Hongwei; Chen, Shufen; Shi, Hongying; Liu, Bin; Wang, Lianhui; Huang, Wei

    2015-02-01

    Wide-angle interference (WI) and multi-beam interference (MI) in microcavity are analyzed separately to improve chromaticity and efficiency of the top-emitting white organic light-emitting diodes (TWOLEDs). A classic electromagnetic theory is used to calculate the resonance intensities of WI and MI in top-emitting organic light-emitting diodes (TOLEDs) with influence factors (e.g., electrodes and exciton locations) being considered. The role of WI on the performances of TOLEDs is revealed through using δ-doping technology and comparing blue and red EML positions in top-emitting and bottom-emitting devices. The blue light intensity significantly increases and the chromaticity of TWOLEDs is further improved with the use of enhanced WI (the blue emitting layer moving towards the reflective electrode) in the case of a weak MI. In addition, the effect of the thicknesses of light output layer and carrier transport layers on WI and MI are also investigated. Apart from the microcavity effect, other factors, e.g., carrier balance and carrier recombination regions are considered to obtain TWOLEDs with high efficiency and improved chromaticity near white light equal-energy point.

  13. Adaptation and visual salience

    PubMed Central

    McDermott, Kyle C.; Malkoc, Gokhan; Mulligan, Jeffrey B.; Webster, Michael A.

    2011-01-01

    We examined how the salience of color is affected by adaptation to different color distributions. Observers searched for a color target on a dense background of distractors varying along different directions in color space. Prior adaptation to the backgrounds enhanced search on the same background while adaptation to orthogonal background directions slowed detection. Advantages of adaptation were seen for both contrast adaptation (to different color axes) and chromatic adaptation (to different mean chromaticities). Control experiments, including analyses of eye movements during the search, suggest that these aftereffects are unlikely to reflect simple learning or changes in search strategies on familiar backgrounds, and instead result from how adaptation alters the relative salience of the target and background colors. Comparable effects were observed along different axes in the chromatic plane or for axes defined by different combinations of luminance and chromatic contrast, consistent with visual search and adaptation mediated by multiple color mechanisms. Similar effects also occurred for color distributions characteristic of natural environments with strongly selective color gamuts. Our results are consistent with the hypothesis that adaptation may play an important functional role in highlighting the salience of novel stimuli by discounting ambient properties of the visual environment. PMID:21106682

  14. Influences of wide-angle and multi-beam interference on the chromaticity and efficiency of top-emitting white organic light-emitting diodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Lingling; Zhou, Hongwei; Chen, Shufen, E-mail: iamsfchen@njupt.edu.cn

    Wide-angle interference (WI) and multi-beam interference (MI) in microcavity are analyzed separately to improve chromaticity and efficiency of the top-emitting white organic light-emitting diodes (TWOLEDs). A classic electromagnetic theory is used to calculate the resonance intensities of WI and MI in top-emitting organic light-emitting diodes (TOLEDs) with influence factors (e.g., electrodes and exciton locations) being considered. The role of WI on the performances of TOLEDs is revealed through using δ-doping technology and comparing blue and red EML positions in top-emitting and bottom-emitting devices. The blue light intensity significantly increases and the chromaticity of TWOLEDs is further improved with the usemore » of enhanced WI (the blue emitting layer moving towards the reflective electrode) in the case of a weak MI. In addition, the effect of the thicknesses of light output layer and carrier transport layers on WI and MI are also investigated. Apart from the microcavity effect, other factors, e.g., carrier balance and carrier recombination regions are considered to obtain TWOLEDs with high efficiency and improved chromaticity near white light equal-energy point.« less

  15. Theory of chromatic noise masking applied to testing linearity of S-cone detection mechanisms.

    PubMed

    Giulianini, Franco; Eskew, Rhea T

    2007-09-01

    A method for testing the linearity of cone combination of chromatic detection mechanisms is applied to S-cone detection. This approach uses the concept of mechanism noise, the noise as seen by a postreceptoral neural mechanism, to represent the effects of superposing chromatic noise components in elevating thresholds and leads to a parameter-free prediction for a linear mechanism. The method also provides a test for the presence of multiple linear detectors and off-axis looking. No evidence for multiple linear mechanisms was found when using either S-cone increment or decrement tests. The results for both S-cone test polarities demonstrate that these mechanisms combine their cone inputs nonlinearly.

  16. Visual evoked potential assessment of the effects of glaucoma on visual subsystems.

    PubMed

    Greenstein, V C; Seliger, S; Zemon, V; Ritch, R

    1998-06-01

    The purpose of this study is to test the hypothesis that glaucoma leads to selective deficits in parallel pathways or channels. Sweep VEPs were obtained to isolated-check stimuli that were modulated sinusoidally in either isoluminant chromatic contrast or in positive and negative luminance contrast. Response functions were obtained from 14 control subjects, 15 patients with open-angle glaucoma, and seven glaucoma suspects. For all three groups of subjects we found characteristic differences between the VEP response functions to isoluminant chromatic contrast stimuli and to luminance contrast stimuli. The isoluminant chromatic stimulus conditions appeared to favor activity of the P-pathway, whereas the luminance contrast stimuli at low depths of modulation favored M-pathway activity. VEP responses for patients with OAG were significantly reduced for chromatic contrast and luminance contrast conditions, whereas VEP responses for glaucoma suspects were significantly reduced only for the 15-Hz positive luminance contrast condition. Our results suggest that both M- and P-pathways are affected by glaucoma.

  17. Chromaticity of color perception and object color knowledge.

    PubMed

    Hsu, Nina S; Frankland, Steven M; Thompson-Schill, Sharon L

    2012-01-01

    Sensorimotor theories of semantic memory require overlap between conceptual and perceptual representations. One source of evidence for such overlap comes from neuroimaging reports of co-activation during memory retrieval and perception; for example, regions involved in color perception (i.e., regions that respond more to colored than grayscale stimuli) are activated by retrieval of object color. One unanswered question from these studies is whether distinctions that are observed during perception are likewise observed during memory retrieval. That is, are regions defined by a chromaticity effect in perception similarly modulated by the chromaticity of remembered objects (e.g., lemons more than coal)? Subjects performed color perception and color retrieval tasks while undergoing fMRI. We observed increased activation during both perception and memory retrieval of chromatic compared to achromatic stimuli in overlapping areas of the left lingual gyrus, but not in dorsal or anterior regions activated during color perception. These results support sensorimotor theories but suggest important distinctions within the conceptual system. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Chronic Exposure to Zinc Chromate Induces Centrosome Amplification and Spindle Assembly Checkpoint Bypass in Human Lung Fibroblasts

    PubMed Central

    Holmes, Amie L.; Wise, Sandra S.; Pelsue, Stephen C.; Aboueissa, AbouEl-Makarim; Lingle, Wilma; Salisbury, Jeffery; Gallagher, Jamie; Wise, John Pierce

    2010-01-01

    Hexavalent chromium (Cr(VI)) compounds are known human lung carcinogens. Solubility plays an important role in its carcinogenicity with the particulate or insoluble form being the most potent. Of the particulate Cr(VI) compounds, zinc chromate appears to be the most potent carcinogen, however, very few studies have investigated its carcinogenic mechanism. In this study, we investigated the ability of chronic exposure to zinc chromate to induce numerical chromosome instability. We found no increase in aneuploidy after a 24 hour exposure to zinc chromate, but with more chronic exposures, zinc chromate induced concentration- and time-dependent increases in aneuploidy in the form of hypodiploidy, hyperdiploidy and tetraploidy. Zinc chromate also induced centrosome amplification in a concentration- and time-dependent manner in both interphase and mitotic cells after chronic exposure, producing cells with centriolar defects. Further, chronic exposure to zinc chromate induced concentration- and time-dependent increases in spindle assembly checkpoint bypass with increases in centromere spreading, premature centromere division and premature anaphase. Lastly, we found that chronic exposure to zinc chromate induced a G2 arrest. All together, these data indicate that zinc chromate can induce chromosome instability after prolonged exposures. PMID:20030412

  19. KINETICS OF CHROMATE REDUCTION DURING NAPHTHALENE DEGRADATION IN A MIXED CULTURE

    EPA Science Inventory

    A mixed culture of Bacillus sp. K1 and Sphingomonas paucimobilis EPA 505 was exposed to chromate and naphthalene. Batch experiments showed that chromate was reduced and naphthalene was degraded by the mixed culture. Chromate reduction occurred initially at a high rate followed by...

  20. Color-motion feature-binding errors are mediated by a higher-order chromatic representation

    PubMed Central

    Shevell, Steven K.; Wang, Wei

    2017-01-01

    Peripheral and central moving objects of the same color may be perceived to move in the same direction even though peripheral objects have a different true direction of motion [Nature 429, 262 (2004)]. The perceived, illusory direction of peripheral motion is a color-motion feature-binding error. Recent work shows that such binding errors occur even without an exact color match between central and peripheral objects, and, moreover, the frequency of the binding errors in the periphery declines as the chromatic difference increases between the central and peripheral objects [J. Opt. Soc. Am. A 31, A60 (2014)]. This change in the frequency of binding errors with the chromatic difference raises the general question of the chromatic representation from which the difference is determined. Here, basic properties of the chromatic representation are tested to discover whether it depends on independent chromatic differences on the l and the s cardinal axes or, alternatively, on a more specific higher-order chromatic representation. Experimental tests compared the rate of feature-binding errors when the central and peripheral colors had the identical s chromaticity (so zero difference in s) and a fixed magnitude of l difference, while varying the identical s level in center and periphery (thus always keeping the s difference at zero). A chromatic representation based on independent l and s differences would result in the same frequency of color-motion binding errors at every s level. The results are contrary to this prediction, thus showing that the chromatic representation at the level of color-motion feature binding depends on a higherorder chromatic mechanism. PMID:26974945

  1. Assessment of the environmental effects associated with wooden bridges preserved with creosote, pentachlorophenol, or chromated copper arsenate

    Treesearch

    Kenneth M. Brooks

    Timber bridges provide an economical alternative to concrete and steel structures, particularly in rural areas with light to moderate vehicle traffic. Wooden components of these bridges are treated with chromated copper arsenate type C (CCA), pentachlorophenol, or creosote to prolong the life of the structure from a few years to many decades. This results in reduced...

  2. Effect of weathering on chromated copper arsenate (CCA) treated wood : leaching of metal salts and change in water repellency

    Treesearch

    R. Sam Williams; Stan Lebow; Patricia Lebow

    2003-01-01

    Wood pressure-treated with chromated copper arsenate (CCA) wood preservative is commonly used for outdoor construction. Oxides of arsenic, copper, and chromium are bound in the wood by a complex series of chemical reactions, but a small percentage of these compounds are gradually released by leaching and weathering. Recent studies suggest that the release of these...

  3. A new optical post-equalization based on self-imaging

    NASA Astrophysics Data System (ADS)

    Guizani, S.; Cheriti, A.; Razzak, M.; Boulslimani, Y.; Hamam, H.

    2005-09-01

    Driven by the world's growing need for communication bandwidth, progress is constantly being reported in building newer fibers that are capable of handling the rapid increase in traffic. However, building an optical fiber link is a major investment, one that is very expensive to replace. A major impairment that restricts the achievement of higher bit rates with standard single mode fiber is chromatic dispersion. This is particularly problematic for systems operating in the 1550 nm band, where the chromatic dispersion limit decreases rapidly in inverse proportion to the square of the bit rate. For the first time, to the best of our knowledge, this document illustrates a new optical technique to post compensate optically the chromatic dispersion in fiber using temporal Talbot effect in ranges exceeding the 40G bit/s. We propose a new optical post equalization solutions based on the self imaging of Talbot effect.

  4. Chromatic effect in a novel THz generation scheme

    NASA Astrophysics Data System (ADS)

    Li, Bin; Zhang, Wenyan; Liu, Xiaoqing; Deng, Haixiao; Lan, Taihe; Liu, Bo; Liu, Jia; Wang, Xingtao; Zeng, Zhinan; Zhang, Lijian

    2017-11-01

    Deriving single or few cycle terahertz (THz) pulse by an intense femtosecond laser through cascaded optical rectification is a crucial technique in cutting-edge time-resolved spectroscopy to characterize micro-scale structures and ultrafast dynamics. Due to the broadband nature of the ultrafast driving laser, the chromatic effect limits the THz conversion efficiency in optical rectification crystals, especially for those implementing the pulse-front tilt scheme, e.g. lithium niobate (LN) crystal, has been prevalently used in the past decade. In this research we developed a brand new type of LN crystal utilizing Brewster coupling, and conducted systematically experimental and simulative investigation for the chromatic effect and multi-dimensionally entangled parameters in THz generation, predicting that an extreme conversion efficiency of ˜10% would be potentially achievable at the THz absorption coefficient of ˜0.5 cm-1. Moreover, we first discovered that the chirp of the driving laser plays a decisive role in the pulse-front tilt scheme, and the THz generation efficiency could be enhanced tremendously by applying an appropriate chirp.

  5. Colorimetric and Spectroradiometric Characteristics of Narrow-Field-of-View Clear Skylight in Granada, Spain

    DTIC Science & Technology

    2001-02-01

    yield chromaticities typical of the blues observed in clear daytime skies. Thus none of our measurements re- flect the far wider chromaticity gamut ...y 5 20.24770 1 2.72203x 2 2.77935x2. (1) The chromaticity gamut of our experimental clear-sky measurements is broader than earlier ones,15–28 despite...chromaticity curves in Figs. 4–7 are typical of those measured on many other days. Not surprisingly, as h0 decreases, the chromaticity gamut measured

  6. Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye.

    PubMed

    Harmening, Wolf M; Tiruveedhula, Pavan; Roorda, Austin; Sincich, Lawrence C

    2012-09-01

    A special challenge arises when pursuing multi-wavelength imaging of retinal tissue in vivo, because the eye's optics must be used as the main focusing elements, and they introduce significant chromatic dispersion. Here we present an image-based method to measure and correct for the eye's transverse chromatic aberrations rapidly, non-invasively, and with high precision. We validate the technique against hyperacute psychophysical performance and the standard chromatic human eye model. In vivo correction of chromatic dispersion will enable confocal multi-wavelength images of the living retina to be aligned, and allow targeted chromatic stimulation of the photoreceptor mosaic to be performed accurately with sub-cellular resolution.

  7. Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye

    PubMed Central

    Harmening, Wolf M.; Tiruveedhula, Pavan; Roorda, Austin; Sincich, Lawrence C.

    2012-01-01

    A special challenge arises when pursuing multi-wavelength imaging of retinal tissue in vivo, because the eye’s optics must be used as the main focusing elements, and they introduce significant chromatic dispersion. Here we present an image-based method to measure and correct for the eye’s transverse chromatic aberrations rapidly, non-invasively, and with high precision. We validate the technique against hyperacute psychophysical performance and the standard chromatic human eye model. In vivo correction of chromatic dispersion will enable confocal multi-wavelength images of the living retina to be aligned, and allow targeted chromatic stimulation of the photoreceptor mosaic to be performed accurately with sub-cellular resolution. PMID:23024901

  8. The Verriest Lecture: Color lessons from space, time, and motion

    PubMed Central

    Shevell, Steven K.

    2012-01-01

    The appearance of a chromatic stimulus depends on more than the wavelengths composing it. The scientific literature has countless examples showing that spatial and temporal features of light influence the colors we see. Studying chromatic stimuli that vary over space, time or direction of motion has a further benefit beyond predicting color appearance: the unveiling of otherwise concealed neural processes of color vision. Spatial or temporal stimulus variation uncovers multiple mechanisms of brightness and color perception at distinct levels of the visual pathway. Spatial variation in chromaticity and luminance can change perceived three-dimensional shape, an example of chromatic signals that affect a percept other than color. Chromatic objects in motion expose the surprisingly weak link between the chromaticity of objects and their physical direction of motion, and the role of color in inducing an illusory motion direction. Space, time and motion – color’s colleagues – reveal the richness of chromatic neural processing. PMID:22330398

  9. Delays in using chromatic and luminance information to correct rapid reaches.

    PubMed

    Kane, Adam; Wade, Alex; Ma-Wyatt, Anna

    2011-09-07

    People can use feedback to make online corrections to movements but only if there is sufficient time to integrate the new information and make the correction. A key variable in this process is therefore the speed at which the new information about the target location is coded. Conduction velocities for chromatic signals are lower than for achromatic signals so it may take longer to correct reaches to chromatic stimuli. In addition to this delay, the sensorimotor system may prefer achromatic information over the chromatic information as delayed information may be less valuable when movements are made under time pressure. A down-weighting of chromatic information may result in additional latencies for chromatically directed reaches. In our study, participants made online corrections to reaches to achromatic, (L-M)-cone, and S-cone stimuli. Our chromatic stimuli were carefully adjusted to minimize stimulation of achromatic pathways, and we equated stimuli both in terms of detection thresholds and also by their estimated neural responses. Similar stimuli were used throughout the subjective adjustments and final reaching experiment. Using this paradigm, we found that responses to achromatic stimuli were only slightly faster than responses to (L-M)-cone and S-cone stimuli. We conclude that the sensorimotor system treats chromatic and achromatic information similarly and that the delayed chromatic responses primarily reflect early conduction delays.

  10. Measurements and modelling of the influence of dentine colour and enamel on tooth colour.

    PubMed

    Battersby, Paul D; Battersby, Stephen J

    2015-03-01

    We provide a quantitative predictive model for the extent to which coloured dentine, visible through the enamel, contributes to tooth colour. Our model uses (L(*),a(*),b(*)) measurements rather than spectral measurements. We have used a model system, composed of a slice of bovine enamel placed on top of coloured paper. We have measured the colour of the enamel-paper combination, as an analogue for a tooth, and have related this to the colour of the paper, as an analogue for dentine. By changing the paper colour, we have been able to explore how the colour of dentine determines tooth colour, according to our model system. We have also compared hydrated and desiccated samples. In qualitative terms, superimposing the enamel on top of the paper increases the "lightness" for all colours tested except white while simultaneously reducing the chromaticity, a measure of the extent to which the colour differs from grey. Desiccated enamel is much more effective at increasing the lightness and reducing the chromaticity than hydrated enamel. Quantitatively, our measurements are reproduced by the mathematical model we have developed to within 2% in "lightness" and about 8% in chromaticity. We are able to predict the colour of an analogue for a tooth, composed of bovine enamel and coloured paper, from the colour of an analogue for the dentine, the coloured paper alone, with good accuracy. This understanding provides insights into the role of dentine colour in determining tooth colour. Our work helps quantify the importance of dentine colour, compared to other, extrinsic causes of colour, such as staining, in determining the visible colour of teeth. Our predicted colours represent a baseline to which extrinsic sources will add. Copyright © 2015. Published by Elsevier Ltd.

  11. Color-motion feature-binding errors are mediated by a higher-order chromatic representation.

    PubMed

    Shevell, Steven K; Wang, Wei

    2016-03-01

    Peripheral and central moving objects of the same color may be perceived to move in the same direction even though peripheral objects have a different true direction of motion [Nature429, 262 (2004)10.1038/429262a]. The perceived, illusory direction of peripheral motion is a color-motion feature-binding error. Recent work shows that such binding errors occur even without an exact color match between central and peripheral objects, and, moreover, the frequency of the binding errors in the periphery declines as the chromatic difference increases between the central and peripheral objects [J. Opt. Soc. Am. A31, A60 (2014)JOAOD60740-323210.1364/JOSAA.31.000A60]. This change in the frequency of binding errors with the chromatic difference raises the general question of the chromatic representation from which the difference is determined. Here, basic properties of the chromatic representation are tested to discover whether it depends on independent chromatic differences on the l and the s cardinal axes or, alternatively, on a more specific higher-order chromatic representation. Experimental tests compared the rate of feature-binding errors when the central and peripheral colors had the identical s chromaticity (so zero difference in s) and a fixed magnitude of l difference, while varying the identical s level in center and periphery (thus always keeping the s difference at zero). A chromatic representation based on independent l and s differences would result in the same frequency of color-motion binding errors at everyslevel. The results are contrary to this prediction, thus showing that the chromatic representation at the level of color-motion feature binding depends on a higher-order chromatic mechanism.

  12. Performance comparison of four kinds of flat nonimaging Fresnel lenses made of polycarbonates and polymethyl methacrylate for concentrated photovoltaics.

    PubMed

    Languy, Fabian; Habraken, Serge

    2011-07-15

    Solar concentrators made of a single refractive primary optics are limited to a concentration ratio of about 1000× [Opt. Express 19, A280 (2011)], due only to longitudinal chromatic aberration, while mirrors are limited to ∼46,000× by the angular size of the Sun. To reduce the chromatic aberration while keeping cost-effective systems for concentrated photovoltaics, a study of four different kinds of flat Fresnel doublets made of polycarbonates and polymethyl methacrylate is presented. It reveals that Fresnel doublets may have fewer optical losses than non-Fresnel doublets, with a lower lateral chromatic split allowing for even higher concentration ratio. © 2011 Optical Society of America

  13. On the locating-chromatic number for graphs with two homogenous components

    NASA Astrophysics Data System (ADS)

    Welyyanti, Des; Baskoro, Edy Tri; Simajuntak, Rinovia; Uttunggadewa, Saladin

    2017-10-01

    The locating-chromatic number of a graph was introduced by Chartrand et al. in 2002. The concept of the locating-chromatic number is a marriage between graph coloring and the notion of graph partition dimension. This concept is only for connected graphs. In [8], we extended this concept also for disconnected graphs. In this paper, we determine the locating- chromatic number of a graph with two components. In particular, we determine such values if the components are homogeneous and each component has locating-chromatic number 3.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vermeul, Vince R.; Szecsody, Jim E.; Truex, Michael J.

    This treatability study was conducted by Pacific Northwest National Laboratory (PNNL), at the request of the U. S. Environmental Protection Agency (EPA) Region 2, to evaluate the feasibility of using in situ treatment technologies for chromate reduction and immobilization at the Puchack Well Field Superfund Site in Pennsauken Township, New Jersey. In addition to in situ reductive treatments, which included the evaluation of both abiotic and biotic reduction of Puchack aquifer sediments, natural attenuation mechanisms were evaluated (i.e., chromate adsorption and reduction). Chromate exhibited typical anionic adsorption behavior, with greater adsorption at lower pH, at lower chromate concentration, and atmore » lower concentrations of other competing anions. In particular, sulfate (at 50 mg/L) suppressed chromate adsorption by up to 50%. Chromate adsorption was not influenced by inorganic colloids.« less

  15. Chronic exposure to particulate chromate induces spindle assembly checkpoint bypass in human lung cells.

    PubMed

    Wise, Sandra S; Holmes, Amie L; Xie, Hong; Thompson, W Douglas; Wise, John Pierce

    2006-11-01

    One of the hallmarks of lung cancer is chromosome instability (CIN), particularly a tetraploid phenotype, which is normally prevented by the spindle assembly checkpoint. Hexavalent chromium Cr(VI) is an established human lung carcinogen, and Cr(VI) induces tumors at lung bifurcation sites where Cr(VI) particles impact and persist. However, the effects of Cr(VI) on the spindle assembly checkpoint are unknown and little is known about prolonged exposure to particulate Cr(VI). Accordingly, we investigated particulate Cr(VI)-induced bypass of the spindle assembly checkpoint after several days of exposure in WHTBF-6 cells. We found that lead chromate indeed induces spindle assembly checkpoint bypass in human lung cells, as 72, 96, and 120 h treatments with 0.5 or 1 microg/cm2 lead chromate induced significant increases in the percentage of cells with aberrant mitotic figures. For example, treatment with 1 microg/cm2 lead chromate for 96 h induced 11, 12.3, and 14% of cells with premature anaphase, centromere spreading and premature centromere division, respectively. In addition, we found a disruption of mitosis with more cells accumulating in anaphase; cells treated for 96 h increased from 18% in controls to 31% in cells treated with lead chromate. To confirm involvement of the spindle assembly checkpoint, Mad2 expression was used as a marker. Mad2 expression was decreased in cells exposed to chronic treatments of lead chromate, consistent with disruption of the checkpoint. We also found concentration- and time-dependent increases in tetraploid cells, which continued to grow and form colonies. When cells were treated with chronic lead alone there was no increase in aberrant mitotic cells or polyploidy; however, chronic exposure to a soluble Cr(VI) showed an increase in aberrant mitotic cells and polyploidy. These data suggest that lead chromate does induce CIN and may be one mechanism in the development of Cr(VI)-induced lung cancer.

  16. Second-order statistics of colour codes modulate transformations that effectuate varying degrees of scene invariance and illumination invariance.

    PubMed

    Mausfeld, Rainer; Andres, Johannes

    2002-01-01

    We argue, from an ethology-inspired perspective, that the internal concepts 'surface colours' and 'illumination colours' are part of the data format of two different representational primitives. Thus, the internal concept of 'colour' is not a unitary one but rather refers to two different types of 'data structure', each with its own proprietary types of parameters and relations. The relation of these representational structures is modulated by a class of parameterised transformations whose effects are mirrored in the idealised computational achievements of illumination invariance of colour codes, on the one hand, and scene invariance, on the other hand. Because the same characteristics of a light array reaching the eye can be physically produced in many different ways, the visual system, then, has to make an 'inference' whether a chromatic deviation of the space-averaged colour codes from the neutral point is due to a 'non-normal', ie chromatic, illumination or due to an imbalanced spectral reflectance composition. We provide evidence that the visual system uses second-order statistics of chromatic codes of a single view of a scene in order to modulate corresponding transformations. In our experiments we used centre surround configurations with inhomogeneous surrounds given by a random structure of overlapping circles, referred to as Seurat configurations. Each family of surrounds has a fixed space-average of colour codes, but differs with respect to the covariance matrix of colour codes of pixels that defines the chromatic variance along some chromatic axis and the covariance between luminance and chromatic channels. We found that dominant wavelengths of red-green equilibrium settings of the infield exhibited a stable and strong dependence on the chromatic variance of the surround. High variances resulted in a tendency towards 'scene invariance', low variances in a tendency towards 'illumination invariance' of the infield.

  17. Psychophysical chromatic mechanisms in macaque monkey.

    PubMed

    Stoughton, Cleo M; Lafer-Sousa, Rosa; Gagin, Galina; Conway, Bevil R

    2012-10-24

    Chromatic mechanisms have been studied extensively with psychophysical techniques in humans, but the number and nature of the mechanisms are still controversial. Appeals to monkey neurophysiology are often used to sort out the competing claims and to test hypotheses arising from the experiments in humans, but psychophysical chromatic mechanisms have never been assessed in monkeys. Here we address this issue by measuring color-detection thresholds in monkeys before and after chromatic adaptation, employing a standard approach used to determine chromatic mechanisms in humans. We conducted separate experiments using adaptation configured as either flickering full-field colors or heterochromatic gratings. Full-field colors would favor activity within the visual system at or before the arrival of retinal signals to V1, before the spatial transformation of color signals by the cortex. Conversely, gratings would favor activity within the cortex where neurons are often sensitive to spatial chromatic structure. Detection thresholds were selectively elevated for the colors of full-field adaptation when it modulated along either of the two cardinal chromatic axes that define cone-opponent color space [L vs M or S vs (L + M)], providing evidence for two privileged cardinal chromatic mechanisms implemented early in the visual-processing hierarchy. Adaptation with gratings produced elevated thresholds for colors of the adaptation regardless of its chromatic makeup, suggesting a cortical representation comprised of multiple higher-order mechanisms each selective for a different direction in color space. The results suggest that color is represented by two cardinal channels early in the processing hierarchy and many chromatic channels in brain regions closer to perceptual readout.

  18. Reduced chromatic discrimination in children with autism spectrum disorders.

    PubMed

    Franklin, Anna; Sowden, Paul; Notman, Leslie; Gonzalez-Dixon, Melissa; West, Dorotea; Alexander, Iona; Loveday, Stephen; White, Alex

    2010-01-01

    Atypical perception in Autism Spectrum Disorders (ASD) is well documented (Dakin & Frith, 2005). However, relatively little is known about colour perception in ASD. Less accurate performance on certain colour tasks has led some to argue that chromatic discrimination is reduced in ASD relative to typical development (Franklin, Sowden, Burley, Notman & Alder, 2008). The current investigation assessed chromatic discrimination in children with high-functioning autism (HFA) and typically developing (TD) children matched on age and non-verbal cognitive ability, using the Farnsworth-Munsell 100 hue test (Experiment 1) and a threshold discrimination task (Experiment 2). In Experiment 1, more errors on the chromatic discrimination task were made by the HFA than the TD group. Comparison with test norms revealed that performance for the HFA group was at a similar level to typically developing children around 3 years younger. In Experiment 2, chromatic thresholds were elevated for the HFA group relative to the TD group. For both experiments, reduced chromatic discrimination in ASD was due to a general reduction in chromatic sensitivity rather than a specific difficulty with either red-green or blue-yellow subsystems of colour vision. The absence of group differences on control tasks ruled out an explanation in terms of general task ability rather than chromatic sensitivity. Theories to account for the reduction in chromatic discrimination in HFA are discussed, and findings are related to cortical models of perceptual processing in ASD.

  19. A distributed code for color in natural scenes derived from center-surround filtered cone signals

    PubMed Central

    Kellner, Christian J.; Wachtler, Thomas

    2013-01-01

    In the retina of trichromatic primates, chromatic information is encoded in an opponent fashion and transmitted to the lateral geniculate nucleus (LGN) and visual cortex via parallel pathways. Chromatic selectivities of neurons in the LGN form two separate clusters, corresponding to two classes of cone opponency. In the visual cortex, however, the chromatic selectivities are more distributed, which is in accordance with a population code for color. Previous studies of cone signals in natural scenes typically found opponent codes with chromatic selectivities corresponding to two directions in color space. Here we investigated how the non-linear spatio-chromatic filtering in the retina influences the encoding of color signals. Cone signals were derived from hyper-spectral images of natural scenes and preprocessed by center-surround filtering and rectification, resulting in parallel ON and OFF channels. Independent Component Analysis (ICA) on these signals yielded a highly sparse code with basis functions that showed spatio-chromatic selectivities. In contrast to previous analyses of linear transformations of cone signals, chromatic selectivities were not restricted to two main chromatic axes, but were more continuously distributed in color space, similar to the population code of color in the early visual cortex. Our results indicate that spatio-chromatic processing in the retina leads to a more distributed and more efficient code for natural scenes. PMID:24098289

  20. Study of Chromatic parameters of Line, Total, Middle graphs and Graph operators of Bipartite graph

    NASA Astrophysics Data System (ADS)

    Nagarathinam, R.; Parvathi, N.

    2018-04-01

    Chromatic parameters have been explored on the basis of graph coloring process in which a couple of adjacent nodes receives different colors. But the Grundy and b-coloring executes maximum colors under certain restrictions. In this paper, Chromatic, b-chromatic and Grundy number of some graph operators of bipartite graph has been investigat

  1. Accurate and fiducial-marker-free correction for three-dimensional chromatic shift in biological fluorescence microscopy.

    PubMed

    Matsuda, Atsushi; Schermelleh, Lothar; Hirano, Yasuhiro; Haraguchi, Tokuko; Hiraoka, Yasushi

    2018-05-15

    Correction of chromatic shift is necessary for precise registration of multicolor fluorescence images of biological specimens. New emerging technologies in fluorescence microscopy with increasing spatial resolution and penetration depth have prompted the need for more accurate methods to correct chromatic aberration. However, the amount of chromatic shift of the region of interest in biological samples often deviates from the theoretical prediction because of unknown dispersion in the biological samples. To measure and correct chromatic shift in biological samples, we developed a quadrisection phase correlation approach to computationally calculate translation, rotation, and magnification from reference images. Furthermore, to account for local chromatic shifts, images are split into smaller elements, for which the phase correlation between channels is measured individually and corrected accordingly. We implemented this method in an easy-to-use open-source software package, called Chromagnon, that is able to correct shifts with a 3D accuracy of approximately 15 nm. Applying this software, we quantified the level of uncertainty in chromatic shift correction, depending on the imaging modality used, and for different existing calibration methods, along with the proposed one. Finally, we provide guidelines to choose the optimal chromatic shift registration method for any given situation.

  2. Efficient removal of chromate and arsenate from individual and mixed system by malachite nanoparticles.

    PubMed

    Saikia, Jiban; Saha, Bedabrata; Das, Gopal

    2011-02-15

    Malachite nanoparticles of 100-150 nm have been efficiently and for the first time used as an adsorbent for the removal of toxic arsenate and chromate. We report a high adsorption capacity for chromate and arsenate on malachite nanoparticle from both individual and mixed solution in pH ∼4-5. However, the adsorption efficiency decreases with the increase of solution pH. Batch studies revealed that initial pH, temperature, malachite nanoparticles dose and initial concentration of chromate and arsenate were important parameters for the adsorption process. Thermodynamic analysis showed that adsorption of chromate and arsenate on malachite nanoparticles is endothermic and spontaneous. The adsorption of these anions has also been investigated quantitatively with the help of adsorption kinetics, isotherm, and selectivity coefficient (K) analysis. The adsorption data for both chromate and arsenate were fitted well in Langmuir isotherm and preferentially followed the second order kinetics. The binding affinity of chromate is found to be slightly higher than arsenate in a competitive adsorption process which leads to the comparatively higher adsorption of chromate on malachite nanoparticles surface. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Psychophysical and physiological responses to gratings with luminance and chromatic components of different spatial frequencies.

    PubMed

    Cooper, Bonnie; Sun, Hao; Lee, Barry B

    2012-02-01

    Gratings that contain luminance and chromatic components of different spatial frequencies were used to study the segregation of signals in luminance and chromatic pathways. Psychophysical detection and discrimination thresholds to these compound gratings, with luminance and chromatic components of the one either half or double the spatial frequency of the other, were measured in human observers. Spatial frequency tuning curves for detection of compound gratings followed the envelope of those for luminance and chromatic gratings. Different grating types were discriminable at detection threshold. Fourier analysis of physiological responses of macaque retinal ganglion cells to compound waveforms showed chromatic information to be restricted to the parvocellular pathway and luminance information to the magnocellular pathway. Taken together, the human psychophysical and macaque physiological data support the strict segregation of luminance and chromatic information in independent channels, with the magnocellular and parvocellular pathways, respectively, serving as likely the physiological substrates. © 2012 Optical Society of America

  4. Post-column reaction for simultaneous analysis of chromatic and leuco forms of malachite green and crystal violet by high-performance liquid chromatography with photometric detection

    USGS Publications Warehouse

    Allen, J.L.; Meinertz, J.R.

    1991-01-01

    The chromatic and leuco forms of malachite green and crystal violet were readily separated and detected by a sensitive and selective high-performance liquid chromatographic procedure. The chromatic and leuco forms of the dyes were separated within 11 min on a C18 column with a mobile phase of 0.05 M sodium acetate and 0.05 M acetic acid in water (19%) and methanol (81%). A reaction chamber, containing 10% PbO2 in Celite 545, was placed between the column and the spectrophotometric detector to oxidize the leuco forms of the dyes to their chromatic forms. Chromatic and leuco malachite green were quantified by their absorbance at 618 nm; and chromatic and leuco Crystal Violet by their absorbance at 588 nm. Detection limits for chromatic and leuco forms of both dyes ranged from 0.12 to 0.28 ng. A linear range of 1 to 100 ng was established for both forms of the dyes.

  5. Calculating correlated color temperatures across the entire gamut of daylight and skylight chromaticities.

    PubMed

    Hernández-Andrés, J; Lee, R L; Romero, J

    1999-09-20

    Natural outdoor illumination daily undergoes large changes in its correlated color temperature (CCT), yet existing equations for calculating CCT from chromaticity coordinates span only part of this range. To improve both the gamut and accuracy of these CCT calculations, we use chromaticities calculated from our measurements of nearly 7000 daylight and skylight spectra to test an equation that accurately maps CIE 1931 chromaticities x and y into CCT. We extend the work of McCamy [Color Res. Appl. 12, 285-287 (1992)] by using a chromaticity epicenter for CCT and the inverse slope of the line that connects it to x and y. With two epicenters for different CCT ranges, our simple equation is accurate across wide chromaticity and CCT ranges (3000-10(6) K) spanned by daylight and skylight.

  6. Dynamics of chromatic visual system processing differ in complexity between children and adults.

    PubMed

    Boon, Mei Ying; Suttle, Catherine M; Henry, Bruce I; Dain, Stephen J

    2009-06-30

    Measures of chromatic contrast sensitivity in children are lower than those of adults. This may be related to immaturities in signal processing at or near threshold. We have found that children's VEPs in response to low contrast supra-threshold chromatic stimuli are more intra-individually variable than those recorded from adults. Here, we report on linear and nonlinear analyses of chromatic VEPs recorded from children and adults. Two measures of signal-to-noise ratio are similar between the adults and children, suggesting that relatively high noise is unlikely to account for the poor clarity of negative and positive peak components in the children's VEPs. Nonlinear analysis indicates higher complexity of adults' than children's chromatic VEPs, at levels of chromatic contrast around and well above threshold.

  7. Accommodation to wavefront vergence and chromatic aberration.

    PubMed

    Wang, Yinan; Kruger, Philip B; Li, James S; Lin, Peter L; Stark, Lawrence R

    2011-05-01

    Longitudinal chromatic aberration (LCA) provides a cue to accommodation with small pupils. However, large pupils increase monochromatic aberrations, which may obscure chromatic blur. In this study, we examined the effect of pupil size and LCA on accommodation. Accommodation was recorded by infrared optometer while observers (nine normal trichromats) viewed a sinusoidally moving Maltese cross target in a Badal stimulus system. There were two illumination conditions: white (3000 K; 20 cd/m) and monochromatic (550 nm with 10 nm bandwidth; 20 cd/m) and two artificial pupil conditions (3 and 5.7 mm). Separately, static measurements of wavefront aberration were made with the eye accommodating to targets between 0 and 4 D (COAS, Wavefront Sciences). Large individual differences in accommodation to wavefront vergence and to LCA are a hallmark of accommodation. LCA continues to provide a signal at large pupil sizes despite higher levels of monochromatic aberrations. Monochromatic aberrations may defend against chromatic blur at high spatial frequencies, but accommodation responds best to optical vergence and to LCA at 3 c/deg where blur from higher order aberrations is less.

  8. Accommodation to Wavefront Vergence and Chromatic Aberration

    PubMed Central

    Wang, Yinan; Kruger, Philip B.; Li, James S.; Lin, Peter L.; Stark, Lawrence R.

    2011-01-01

    Purpose Longitudinal chromatic aberration (LCA) provides a cue to accommodation with small pupils. However, large pupils increase monochromatic aberrations, which may obscure chromatic blur. In the present study, we examined the effect of pupil size and LCA on accommodation. Methods Accommodation was recorded by infrared optometer while observers (nine normal trichromats) viewed a sinusoidally moving Maltese cross target in a Badal stimulus system. There were two illumination conditions: white (3000 K; 20 cd/m2) and monochromatic (550 nm with 10 nm bandwidth; 20 cd/m2) and two artificial pupil conditions (3 mm and 5.7 mm). Separately, static measurements of wavefront aberration were made with the eye accommodating to targets between 0 and 4 D (COAS, Wavefront Sciences). Results Large individual differences in accommodation to wavefront vergence and to LCA are a hallmark of accommodation. LCA continues to provide a signal at large pupil sizes despite higher levels of monochromatic aberrations. Conclusions Monochromatic aberrations may defend against chromatic blur at high spatial frequencies, but accommodation responds best to optical vergence and to LCA at 3 c/deg where blur from higher order aberrations is less. PMID:21317666

  9. The mammalian spot test and its use for the testing of potential carcinogenicity of welding fume particles and hexavalent chromium.

    PubMed

    Knudsen, I

    1980-07-01

    Welding fume particles, potassium chromate and cyclophosphamide are tested in the mammalian spot test. Female mice C57BL/6J/BOM9 weeks old have been mated to T-stock male mice and treated with welding fume particles 100 mg/kg, potassium chromate 20 or 10 mg/kg, or cyclophosphamide 10 or 2.5 mg/kg intraperitoneally at day 8, 9 and 10 of pregnancy. The fur of the offspring was checked week 2 through week 5 after birth for coloured spots. The characterisation of the different types of spots are discussed. Welding fume particles 100 mg/kg and potassium chromate 10 mg/kg induce approximately to the same extent as cyclophosphamde 2.5 mg/kg, grayish or brownish spots in tvo screening test for mutagenic and carcinogenic potential of chemicals. The positive results for potassium chromate and cyclophosphamide are in agreement with previous in vitro experiments and confirm the sensitivity of the test. The effect of welding fume particles in this in vivo system suggests a potential risk for humans directly exposed to welding fumes.

  10. Occupational dermatoses: An Asian perspective.

    PubMed

    Bhatia, Riti; Sharma, Vinod Kumar

    2017-01-01

    Occupational dermatoses contribute to a significant portion of work-related diseases, especially in Asia, where a major portion of the workforce is in the unorganized sector. This review article is focussed on the frequency and pattern of occupational skin diseases reported across Asian countries and type of allergens implicated in different occupations. The literature was searched systematically using key words 'occupational dermatoses,' 'occupational skin disease' and name of each Asian country. Ninty five full-text articles were considered relevant and evaluated. Some of the dermatoses seen in industrial workers in Asian countries are similar to those in Western countries, including dermatoses due to chromate in construction and electroplating workers, epoxy resin, and chromate in painters, wood dust in workers in the furniture industry, azo dyes in textile workers and formaldehyde and chromates in those working in the leather and dyeing industries, dermatoses in domestic workers, chefs and health-care workers. Dermatoses in workers engaged in agriculture, beedi (tiny cigars) manufacture, agarbatti (incense sticks) production, fish processing, carpet weaving, sanitation and those working in coffee plantations and coal mines appear to be unique to Asian countries. Recognition of clinical patterns and geographic variations in occupational skin diseases will provide an impetus to further strengthen future research in these areas, as well as improving their management.

  11. Reduction of Hexavalent Chromium and Detection of Chromate Reductase (ChrR) in Stenotrophomonas maltophilia.

    PubMed

    Baldiris, Rosa; Acosta-Tapia, Natali; Montes, Alfredo; Hernández, Jennifer; Vivas-Reyes, Ricardo

    2018-02-13

    An Gram negative strain of S. maltophilia , indigenous to environments contaminated by Cr(VI) and identified by biochemical methods and 16S rRNA gene analysis, reduced chromate by 100%, 98-99% and 92% at concentrations in the 10-70, 80-300, and 500 mg/L range, respectively at pH 7 and temperature 37 °C. Increasing concentrations of Cr(VI) in the medium lowered the growth rate but could not be directly correlated with the amount of Cr(VI) reduced. The strain also exhibited multiple resistance to antibiotics and tolerance and resistance to various heavy metals (Ni, Zn and Cu), with the exception of Hg. Hexavalent chromium reduction was mainly associated with the soluble fraction of the cell evaluated with crude cell-free extracts. A protein of molecular weight around 25 kDa was detected on SDS-PAGE gel depending on the concentration of hexavalent chromium in the medium (0, 100 and 500 mg/L). In silico analysis in this contribution, revealed the presence of the chromate reductase gene ChrR in S. maltophilia , evidenced through a fragment of around 468 bp obtained experimentally. High Cr(VI) concentration resistance and high Cr(VI) reducing ability of the strain make it a suitable candidate for bioremediation.

  12. Availability of color calibration for consistent color display in medical images and optimization of reference brightness for clinical use

    NASA Astrophysics Data System (ADS)

    Iwai, Daiki; Suganami, Haruka; Hosoba, Minoru; Ohno, Kazuko; Emoto, Yutaka; Tabata, Yoshito; Matsui, Norihisa

    2013-03-01

    Color image consistency has not been accomplished yet except the Digital Imaging and Communication in Medicine (DICOM) Supplement 100 for implementing a color reproduction pipeline and device independent color spaces. Thus, most healthcare enterprises could not check monitor degradation routinely. To ensure color consistency in medical color imaging, monitor color calibration should be introduced. Using simple color calibration device . chromaticity of colors including typical color (Red, Green, Blue, Green and White) are measured as device independent profile connection space value called u'v' before and after calibration. In addition, clinical color images are displayed and visual differences are observed. In color calibration, monitor brightness level has to be set to quite lower value 80 cd/m2 according to sRGB standard. As Maximum brightness of most color monitors available currently for medical use have much higher brightness than 80 cd/m2, it is not seemed to be appropriate to use 80 cd/m2 level for calibration. Therefore, we propose that new brightness standard should be introduced while maintaining the color representation in clinical use. To evaluate effects of brightness to chromaticity experimentally, brightness level is changed in two monitors from 80 to 270cd/m2 and chromaticity value are compared with each brightness levels. As a result, there are no significant differences in chromaticity diagram when brightness levels are changed. In conclusion, chromaticity is close to theoretical value after color calibration. Moreover, chromaticity isn't moved when brightness is changed. The results indicate optimized reference brightness level for clinical use could be set at high brightness in current monitors .

  13. Spatio-Chromatic Adaptation via Higher-Order Canonical Correlation Analysis of Natural Images

    PubMed Central

    Gutmann, Michael U.; Laparra, Valero; Hyvärinen, Aapo; Malo, Jesús

    2014-01-01

    Independent component and canonical correlation analysis are two general-purpose statistical methods with wide applicability. In neuroscience, independent component analysis of chromatic natural images explains the spatio-chromatic structure of primary cortical receptive fields in terms of properties of the visual environment. Canonical correlation analysis explains similarly chromatic adaptation to different illuminations. But, as we show in this paper, neither of the two methods generalizes well to explain both spatio-chromatic processing and adaptation at the same time. We propose a statistical method which combines the desirable properties of independent component and canonical correlation analysis: It finds independent components in each data set which, across the two data sets, are related to each other via linear or higher-order correlations. The new method is as widely applicable as canonical correlation analysis, and also to more than two data sets. We call it higher-order canonical correlation analysis. When applied to chromatic natural images, we found that it provides a single (unified) statistical framework which accounts for both spatio-chromatic processing and adaptation. Filters with spatio-chromatic tuning properties as in the primary visual cortex emerged and corresponding-colors psychophysics was reproduced reasonably well. We used the new method to make a theory-driven testable prediction on how the neural response to colored patterns should change when the illumination changes. We predict shifts in the responses which are comparable to the shifts reported for chromatic contrast habituation. PMID:24533049

  14. Spatio-chromatic adaptation via higher-order canonical correlation analysis of natural images.

    PubMed

    Gutmann, Michael U; Laparra, Valero; Hyvärinen, Aapo; Malo, Jesús

    2014-01-01

    Independent component and canonical correlation analysis are two general-purpose statistical methods with wide applicability. In neuroscience, independent component analysis of chromatic natural images explains the spatio-chromatic structure of primary cortical receptive fields in terms of properties of the visual environment. Canonical correlation analysis explains similarly chromatic adaptation to different illuminations. But, as we show in this paper, neither of the two methods generalizes well to explain both spatio-chromatic processing and adaptation at the same time. We propose a statistical method which combines the desirable properties of independent component and canonical correlation analysis: It finds independent components in each data set which, across the two data sets, are related to each other via linear or higher-order correlations. The new method is as widely applicable as canonical correlation analysis, and also to more than two data sets. We call it higher-order canonical correlation analysis. When applied to chromatic natural images, we found that it provides a single (unified) statistical framework which accounts for both spatio-chromatic processing and adaptation. Filters with spatio-chromatic tuning properties as in the primary visual cortex emerged and corresponding-colors psychophysics was reproduced reasonably well. We used the new method to make a theory-driven testable prediction on how the neural response to colored patterns should change when the illumination changes. We predict shifts in the responses which are comparable to the shifts reported for chromatic contrast habituation.

  15. Chromate Reduction by a Pseudomonad Isolated from a Site Contaminated with Chromated Copper Arsenate

    PubMed Central

    McLean, Jeff; Beveridge, Terry J.

    2001-01-01

    A pseudomonad (CRB5) isolated from a decommissioned wood preservation site reduced toxic chromate [Cr(VI)] to an insoluble Cr(III) precipitate under aerobic and anaerobic conditions. CRB5 tolerated up to 520 mg of Cr(VI) liter−1 and reduced chromate in the presence of copper and arsenate. Under anaerobic conditions it also reduced Co(III) and U(VI), partially internalizing each metal. Metal precipitates were also found on the surface of the outer membrane and (sometimes) on a capsule. The results showed that chromate reduction by CRB5 was mediated by a soluble enzyme that was largely contained in the cytoplasm but also found outside of the cells. The crude reductase activity in the soluble fraction showed a Km of 23 mg liter−1 (437 μM) and a Vmax of 0.98 mg of Cr h−1 mg of protein−1 (317 nmol min−1 mg of protein−1). Minor membrane-associated Cr(VI) reduction under anaerobiosis may account for anaerobic reduction of chromate under nongrowth conditions with an organic electron donor present. Chromate reduction under both aerobic and anaerobic conditions may be a detoxification strategy for the bacterium which could be exploited to bioremediate chromate-contaminated or other toxic heavy metal-contaminated environments. PMID:11229894

  16. Influence of Spatial and Chromatic Noise on Luminance Discrimination.

    PubMed

    Miquilini, Leticia; Walker, Natalie A; Odigie, Erika A; Guimarães, Diego Leite; Salomão, Railson Cruz; Lacerda, Eliza Maria Costa Brito; Cortes, Maria Izabel Tentes; de Lima Silveira, Luiz Carlos; Fitzgerald, Malinda E C; Ventura, Dora Fix; Souza, Givago Silva

    2017-12-05

    Pseudoisochromatic figures are designed to base discrimination of a chromatic target from a background solely on the chromatic differences. This is accomplished by the introduction of luminance and spatial noise thereby eliminating these two dimensions as cues. The inverse rationale could also be applied to luminance discrimination, if spatial and chromatic noise are used to mask those cues. In this current study estimate of luminance contrast thresholds were conducted using a novel stimulus, based on the use of chromatic and spatial noise to mask the use of these cues in a luminance discrimination task. This was accomplished by presenting stimuli composed of a mosaic of circles colored randomly. A Landolt-C target differed from the background only by the luminance. The luminance contrast thresholds were estimated for different chromatic noise saturation conditions and compared to luminance contrast thresholds estimated using the same target in a non-mosaic stimulus. Moreover, the influence of the chromatic content in the noise on the luminance contrast threshold was also investigated. Luminance contrast threshold was dependent on the chromaticity noise strength. It was 10-fold higher than thresholds estimated from non-mosaic stimulus, but they were independent of colour space location in which the noise was modulated. The present study introduces a new method to investigate luminance vision intended for both basic science and clinical applications.

  17. Using chromate to investigate the impact of natural organics on the surface reactivity of nanoparticulate magnetite

    USGS Publications Warehouse

    Swindle, Andrew L.; Cozzarelli, Isabelle M.; Elwood Madden, Andrew S.

    2015-01-01

    Chromate was used as a chemical probe to investigate the size-dependent influence of organics on nanoparticle surface reactivity. Magnetite–chromate sorption experiments were conducted with ∼90 and ∼6 nm magnetite nanoparticles in the presence and absence of fulvic acid (FA), natural organic matter (NOM), and isolated landfill leachate (LL). Results indicated that low concentrations (1 mg/L) of organics had no noticeable impact on chromate sorption, whereas concentrations of 50 mg/L or more resulted in decreased amounts of chromate sorption. The adsorption of organics onto the magnetite surfaces interfered equally with the ability of the 6 and 90 nm particles to sorb chromate from solution, despite the greater surface area of the smaller particles. Results indicate the presence of organics did not impact the redox chemistry of the magnetite–chromate system over the duration of the experiments (8 h), nor did the organics interact with the chromate in solution. Brunauer–Emmett–Teller (BET) and scanning electron microscopy (SEM) results indicate that the organics blocked the surface reactivity by occupying surface sites on the particles. The similarity of results with FA and NOM suggests that coverage of the reactive mineral surface is the main factor behind the inhibition of surface reactivity in the presence of organics.

  18. Chromatic dispersion concentrator applied to photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Sassi, G.

    1980-01-01

    The aim of this paper is to show how it is possible to realize a chromatic dispersion concentrator which collects the different monochromatic components of the solar spectrum separately in subsequently concentric rings in the focal zone. This comes about without an increase in the energetic losses compared to any other type of concentrator. If different photovoltaic elements with energy gaps equal to the photon energy falling on the focal zone are put in the latter, energy losses due to incomplete utilization of the solar spectrum and to incomplete utilization of the energy of a single photon can be drastically reduced. How the losses due to the voltage factor and the fill-factor of the photovoltaic elements of the system can be reduced compared to the normal silicon cells is also demonstrated. The other contributions to losses in the conversion process have only been mentioned, foreseeing their possible variation.

  19. Third-rank chromatic aberrations of electron lenses.

    PubMed

    Liu, Zhixiong

    2018-02-01

    In this paper the third-rank chromatic aberration coefficients of round electron lenses are analytically derived and numerically calculated by Mathematica. Furthermore, the numerical results are cross-checked by the differential algebraic (DA) method, which verifies that all the formulas for the third-rank chromatic aberration coefficients are completely correct. It is hoped that this work would be helpful for further chromatic aberration correction in electron microscopy. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Twilight and Daytime Colors of the Clear Sky

    DTIC Science & Technology

    1994-07-20

    greatly, with some surprising consequences for their calorimetric gamuts . Key words: Atmospheric optics, clear-sky chromaticities, blue sky, twilight...First we calculate a chromaticity curve’s unnormal- ized clorimetric gamut g by finding the curve’s average chromaticity [here, its mean CIE (Commis...calorimetric gamut , g. Taking the spectrum locus as an upper limit on color gamut , we use its gamut to normalize any other chromaticity 20 July 1994 / Vol

  1. Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

    PubMed

    Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang

    2014-01-01

    An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.

  2. Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes.

    PubMed

    Cabezos, Inmaculada; Luque, Maria Jos; de Fez, Dolores; Moncho, Vicenta; Camps, Vicente

    2015-02-01

    Some diseases that affect the visual system may show loss of chromatic-achromatic sensitivity before obvious physical signs appear in the usual examination of the eye's posterior segment. A perimetric study has been conducted with four typical patients with glaucoma and diabetes, at different stages of the disease. In addition to the standard white-on-white (standard automated perimetry [SAP]), a test battery has been used to study patient's contrast sensitivity, using stimuli with different chromatic, spatial, and temporal content (multichannel perimetry). The choice of stimuli tries to maximize the response of different visual mechanisms: Achromatic (parvocellular and magnocellular origin); chromatic red-green (parvocellular origin); and chromatic blue-yellow (koniocellular origin). The results seem to indicate losses in the achromatic-parvocellular perimetry and both chromatic perimetry tests, undetected by conventional SAP. Our results illustrate that our patients without visible retinal alterations show signs of suspicion in multichannel perimetry.

  3. Redefining White Light Chromaticity Boundaries for Aviation

    DOT National Transportation Integrated Search

    2009-10-05

    Several aspects are involved in the recognition of an aviation signal light's color, including its chromaticity, layout on the airfield, and the chromaticity of other light sources in view. The LRC conducted a human factors investigation of the bound...

  4. Efficient estimation and large-scale evaluation of lateral chromatic aberration for digital image forensics

    NASA Astrophysics Data System (ADS)

    Gloe, Thomas; Borowka, Karsten; Winkler, Antje

    2010-01-01

    The analysis of lateral chromatic aberration forms another ingredient for a well equipped toolbox of an image forensic investigator. Previous work proposed its application to forgery detection1 and image source identification.2 This paper takes a closer look on the current state-of-the-art method to analyse lateral chromatic aberration and presents a new approach to estimate lateral chromatic aberration in a runtime-efficient way. Employing a set of 11 different camera models including 43 devices, the characteristic of lateral chromatic aberration is investigated in a large-scale. The reported results point to general difficulties that have to be considered in real world investigations.

  5. Achromatic synesthesias - a functional magnetic resonance imaging study.

    PubMed

    Melero, H; Ríos-Lago, M; Peña-Melián, A; Álvarez-Linera, J

    2014-09-01

    Grapheme-color synesthetes experience consistent, automatic and idiosyncratic colors associated with specific letters and numbers. Frequently, these specific associations exhibit achromatic synesthetic qualities (e.g. white, black or gray). In this study, we have investigated for the first time the neural basis of achromatic synesthesias, their relationship to chromatic synesthesias and the achromatic congruency effect in order to understand not only synesthetic color but also other components of the synesthetic experience. To achieve this aim, functional magnetic resonance imaging experiments were performed in a group of associator grapheme-color synesthetes and matched controls who were stimulated with real chromatic and achromatic stimuli (Mondrians), and with letters and numbers that elicited different types of grapheme-color synesthesias (i.e. chromatic and achromatic inducers which elicited chromatic but also achromatic synesthesias, as well as congruent and incongruent ones). The information derived from the analysis of Mondrians and chromatic/achromatic synesthesias suggests that real and synesthetic colors/achromaticity do not fully share neural mechanisms. The whole-brain analysis of BOLD signals in response to the complete set of synesthetic inducers revealed that the functional peculiarities of the synesthetic brain are distributed, and reflect different components of the synesthetic experience: a perceptual component, an (attentional) feature binding component, and an emotional component. Additionally, the inclusion of achromatic experiences has provided new evidence in favor of the emotional binding theory, a line of interpretation which constitutes a bridge between grapheme-color synesthesia and other developmental modalities of the phenomenon. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Ganglion Cell Loss and Age-Related Visual Loss: A Cortical Pooling Analysis

    PubMed Central

    SCHMIDT, LAURA A.; LY-SCHROEDER, EMILY; SWANSON, WILLIAM H.

    2006-01-01

    Purpose To evaluate the ability of the cortical pooling model to predict the effects of random, mild ganglion cell loss, we compared the predictions of the model with the age-related loss and variability in achromatic and chromatic contrast sensitivity. Methods The relative sensitivity to small (0.5°) and large (3.0°) stimuli was compared in older (mean = 67 years, n = 27) and younger (mean = 23 years, n = 32) adults. Contrast sensitivity for modulations along the luminance, equiluminant L-cone, and equiluminant S-cone axes was assessed at the fovea and at four peripheral locations (12°). Results When the stimuli were large, threshold measurements obtained from all participants were reliable and well within the range of modulations along the chromatic axes that could be produced by the phosphors of the CRT. For the large stimuli, neither long- nor short-term variability increased as a function of age. Increasing the size of the stimulus did not decrease the magnitude of the age-related losses when the stimulus was chromatic, and visual losses observed with large chromatic stimuli were not different from those obtained with small achromatic stimuli. Moreover, chromatic contrast sensitivity assessments identified significant visual losses in four individuals who were not identified by achromatic contrast sensitivity assessments and only missed identifying one individual with significant losses in achromatic contrast sensitivity. Conclusions The declines in achromatic and chromatic sensitivity as a function of age (0.4 – 0.7 dB per decade) were similar to those obtained in previous studies of achromatic and chromatic perimetry and are consistent with the loss of retinal ganglion cells reported in histologic studies. The results of this study are consistent with the predictions the cortical pooling model makes for both variability and contrast sensitivity. These findings emphasize that selective visual impairments do not necessarily reflect preferential damage to a single ganglion cell class and that it is important to include the influence of higher cortical processing when quantifying the relation between ganglion cells and visual function. PMID:16840870

  7. Effects of longitudinal chromatic aberration on accommodation and emmetropization.

    PubMed

    Seidemann, Anne; Schaeffel, Frank

    2002-09-01

    Less accommodation was found when human subjects read in blue (peak at about 440 nm) than when they read in red light (above 600 nm; [Kroger & Binder, British Journal of Ophthalmology 84 (2000) 890]). On the other hand, emmetropization in chickens did not appear to compensate for the chromatic defocus (385 nm versus 665 nm; [Rohrer, Schaeffel & Zrenner, Journal of Physiology 449 (1992) 363]). The apparently contradictory result was studied in more detail in humans and chickens. Accommodation was measured with an eccentric infrared photorefractor, the PowerRefractor, in human subjects reading under quasi-monochromatic illumination conditions. Chickens were refracted in quasi-monochromatic ambient illumination but with no particular fixation target. In a second experiment, they were also raised in monochromatic light for two days and subsequently refracted both in complete darkness, in monochromatic light, and in white light, both without and with cycloplegia. Consistent with the initial report by Kroger and Binder [British Journal of Ophthalmology 84 (2000) 890], accommodation in human subjects was found to shift in accordance with the chromatic aberration function. An immediate shift in accommodation tonus was also found in the chickens when they were refracted under red and in blue ambient illumination (average difference between refractions in both conditions: 1.26+/-0.54 D, p<0.001 paired t-test). This value is close to the chromatic focus difference between the two wavelengths (1.5 D [Mandelman & Sivak, Vision Research 23 (1983) 1555]). When chickens were raised in blue or red light for two days, and their refractions were subsequently measured in complete darkness, they showed also a difference in refractions (1.41+/-1.00 D; ANOVA: p<0.0012, post hoc t-test: at least p<0.05 among different groups). This difference was no longer significant when they were refracted in white light but became again significant when they were cyclopleged (0.57+/-0.58 D, p=0.039, unpaired t-test). The latter observation makes it unlikely that the difference resulted just from a shift in the resting tonus of accommodation. (1) Imposed chromatic defocus produces a shift in accommodation tonus in both humans and chickens which is, in the case of the chicken, followed by a shift in cycloplegic refractive state into the same direction, (2) the difference to the previous study by Rohrer, Schaeffel and Zrenner [Journal of Physiology 449 (1992) 363] can be explained from the fact that shorter wavelengths were used than in the present study, at which emmetropization was no longer functional and, (3) the small amplitude and the variability of the shifts in refraction do not allow clear statements about the role of the "lag of accommodation" in refractive development but they show that several cone types contribute to emmetropization.

  8. Orientation tuning of binocular summation: a comparison of colour to achromatic contrast

    PubMed Central

    Gheiratmand, Mina; Cherniawsky, Avital S.; Mullen, Kathy T.

    2016-01-01

    A key function of the primary visual cortex is to combine the input from the two eyes into a unified binocular percept. At low, near threshold, contrasts a process of summation occurs if the visual inputs from the two eyes are similar. Here we measure the orientation tuning of binocular summation for chromatic and equivalent achromatic contrast. We derive estimates of orientation tuning by measuring binocular summation as a function of the orientation difference between two sinusoidal gratings presented dichoptically to different eyes. We then use a model to estimate the orientation bandwidth of the neural detectors underlying the binocular combination. We find that orientation bandwidths are similar for chromatic and achromatic stimuli at both low (0.375 c/deg) and mid (1.5 c/deg) spatial frequencies, with an overall average of 29 ± 3 degs (HWHH, s.e.m). This effect occurs despite the overall greater binocular summation found for the low spatial frequency chromatic stimuli. These results suggest that similar, oriented processes underlie both chromatic and achromatic binocular contrast combination. The non-oriented detection process found in colour vision at low spatial frequencies under monocular viewing is not evident at the binocular combination stage. PMID:27168119

  9. Estimation of chromatic errors from broadband images for high contrast imaging

    NASA Astrophysics Data System (ADS)

    Sirbu, Dan; Belikov, Ruslan

    2015-09-01

    Usage of an internal coronagraph with an adaptive optical system for wavefront correction for direct imaging of exoplanets is currently being considered for many mission concepts, including as an instrument addition to the WFIRST-AFTA mission to follow the James Web Space Telescope. The main technical challenge associated with direct imaging of exoplanets with an internal coronagraph is to effectively control both the diffraction and scattered light from the star so that the dim planetary companion can be seen. For the deformable mirror (DM) to recover a dark hole region with sufficiently high contrast in the image plane, wavefront errors are usually estimated using probes on the DM. To date, most broadband lab demonstrations use narrowband filters to estimate the chromaticity of the wavefront error, but this reduces the photon flux per filter and requires a filter system. Here, we propose a method to estimate the chromaticity of wavefront errors using only a broadband image. This is achieved by using special DM probes that have sufficient chromatic diversity. As a case example, we simulate the retrieval of the spectrum of the central wavelength from broadband images for a simple shaped- pupil coronagraph with a conjugate DM and compute the resulting estimation error.

  10. In vivo subjective and objective longitudinal chromatic aberration after bilateral implantation of the same design of hydrophobic and hydrophilic intraocular lenses.

    PubMed

    Vinas, Maria; Dorronsoro, Carlos; Garzón, Nuria; Poyales, Francisco; Marcos, Susana

    2015-10-01

    To measure the longitudinal chromatic aberration in vivo using psychophysical and wavefront-sensing methods in patients with bilateral implantation of monofocal intraocular lenses (IOLs) of similar aspheric design but different materials (hydrophobic Podeye and hydrophilic Poday). Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain. Prospective observational study. Measurements were performed with the use of psychophysical (480 to 700 nm) and wavefront-sensing (480 to 950 nm) methods using a custom-developed adaptive optics system. Chromatic difference-of-focus curves were obtained from best-focus data at each wavelength, and the longitudinal chromatic aberration was obtained from the slope of linear regressions to those curves. The longitudinal chromatic aberration from psychophysical measurements was 1.37 diopters (D) ± 0.08 (SD) (hydrophobic) and 1.21 ± 0.08 D (hydrophilic). From wavefront-sensing, the longitudinal chromatic aberration was 0.88 ± 0.07 D and 0.73 ± 0.09 D, respectively. At 480 to 950 nm, the longitudinal chromatic aberration was 1.27 ± 0.09 D (hydrophobic) and 1.02 ± 0.13 D (hydrophilic). The longitudinal chromatic aberration was consistently higher in eyes with the hydrophobic IOL than in eyes with the hydrophilic IOL (a difference of 0.16 D and 0.15 D, respectively). Similar to findings in young phakic eyes, the longitudinal chromatic aberration from the psychophysical method was consistently higher than from wavefront-sensing, by 0.48 D (35.41%) for the hydrophobic IOL and 0.48 D (39.43%) for the hydrophilic IOL. Longitudinal chromatic aberrations were smaller with hydrophilic IOLs than with hydrophobic IOLs of the same design. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Non Chromate, ZVOC Coatings for Steel Substrates on Army and Navy Aircraft and Ground Vehicles: Non Chromate Sealers for Zinc Phosphate

    DTIC Science & Technology

    2017-04-30

    Defense, “Chemical Agent Resistant Coating (CARC) System Application Procedures and Quality Control Inspection”, Washington, DC, June 2003. 4. Non ...WP-200906) Non -Chromate, ZVOC Coatings for Steel Substrates on Army and Navy Aircraft and Ground Vehicles Non -Chromate Sealers for Zinc...comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE

  12. [Analysis of chromatic value of gingival porcelain].

    PubMed

    Wang, Min; Sun, Jun; Chao, Yong-Lie

    2005-08-01

    To study the distribution of the chromatic value of gingival porcelains. The color change of Shofu VINTAGE and Vita VMK95 gingival porcelains on the black and white backings was determined with a spectrophotometer (PR-650). The results showed that the chromatic value of gingival porcelains was different on varying backings. The color space of gingival porcelain was L*: 41.85 - 50.64, a*: 12.46 - 19.46, b*: 1.33 - 4.62. The chromatic value distribution cannot cover the color region of natural gingiva.

  13. Thermodynamic Properties of M2EO4, M2Mo x O3 x + 1 and Double Chromates (M = Li, Na, K, Rb, Cs; E = Cr, Mo, W)

    NASA Astrophysics Data System (ADS)

    Suponitskiy, Yu. L.; Zolotova, E. S.; Dyunin, A. G.; Liashenko, S. E.

    2018-03-01

    The phase transition temperatures of chromates and molybdates of certain alkali metals, and the melting temperature and enthalpy of polymorphic transformations for tungstates, are determined by means of thermal analysis. Enthalpies of dissolution of rubidium and cesium chromates in water and enthalpies of dissolution of alkali metal tungstates in a melt at 923 K are measured via calorimetry. Standard enthalpies of formation of sought chromates are calculated. The linear correlations between the enthalpies of formation of sulfates, selenates, chromates, tungstates, and molybdates are established, and a linear correlation within - (Δ G o ox)-1-(Δ MV)ox)-1 coordinates is found for isopolymolybdates.

  14. Uncertainty of chromatic dispersion estimation from transmitted waveforms in direct detection systems

    NASA Astrophysics Data System (ADS)

    Lach, Zbigniew T.

    2017-08-01

    A possibility is shown of a non-disruptive estimation of chromatic dispersion in a fiber of an intensity modulation communication line under work conditions. Uncertainty of the chromatic dispersion estimates is analyzed and quantified with the use of confidence intervals.

  15. Zinc Chromate Induces Chromosome Instability and DNA Double Strand Breaks in Human Lung Cells

    PubMed Central

    Xie, Hong; Holmes, Amie L.; Young, Jamie L.; Qin, Qin; Joyce, Kellie; Pelsue, Stephen C.; Peng, Cheng; Wise, Sandra S.; Jeevarajan, Antony S.; Wallace, William T.; Hammond, Dianne; Wise, John Pierce

    2014-01-01

    Hexavalent chromium Cr(VI) is a respiratory toxicant and carcinogen, with solubility playing an important role in its carcinogenic potential. Zinc chromate, a water insoluble or ‘particulate’ Cr(VI) compound, has been shown to be carcinogenic in epidemiology studies and to induce tumors in experimental animals, but its genotoxicity is poorly understood. Our study shows that zinc chromate induced concentration-dependent increases in cytotoxicity, chromosome damage and DNA double strand breaks in human lung cells. In response to zinc chromate-induced breaks, MRE11 expression was increased and ATM and ATR were phosphorylated, indicating that the DNA double strand break repair system was initiated in the cells. In addition, our data show that zinc chromate-induced double strand breaks were only observed in the G2/M phase population, with no significant amount of double strand breaks observed in G1 and S phase cells. These data will aid in understanding the mechanisms of zinc chromate toxicity and carcinogenesis. PMID:19027772

  16. Visual reaction time for chromaticity changes at constant luminance in different color representation systems

    NASA Astrophysics Data System (ADS)

    Jimenezdel Barco, L.; Jimenez, J. R.; Rubino, M.; Diaz, J. A.

    1996-09-01

    The results obtained by different authors show that when a color stimulus changes in both luminance and chromaticity, the visual reaction time (VRT) of an observer in detecting this chromatic change depends on nothing more than the luminance change and is regulated by Pieron's law. In the present work, we evaluate the VRT needed by an observer to detect the chromaticity difference between an adapting and variable stimulus. For this, we have used the experimental method of hue substitution, which allows us to maintain the luminance channel constant and thereby study the temporal response to changes only in chromaticity. The experiments were carried out with a CRT color monitor and the experimental results are expressed in different color-representation systems. The systems UCS-CIE 1964 (U*, V*, W*) and CIELUV show good correlations between the VRT and the chromaticity difference expressed in these systems, adjusting the VRT to an expression following Pieron's law: VRT-VRTon=k( Delta E)- beta .

  17. Detection of chromatic and luminance distortions in natural scenes.

    PubMed

    Jennings, Ben J; Wang, Karen; Menzies, Samantha; Kingdom, Frederick A A

    2015-09-01

    A number of studies have measured visual thresholds for detecting spatial distortions applied to images of natural scenes. In one study, Bex [J. Vis.10(2), 1 (2010)10.1167/10.2.231534-7362] measured sensitivity to sinusoidal spatial modulations of image scale. Here, we measure sensitivity to sinusoidal scale distortions applied to the chromatic, luminance, or both layers of natural scene images. We first established that sensitivity does not depend on whether the undistorted comparison image was of the same or of a different scene. Next, we found that, when the luminance but not chromatic layer was distorted, performance was the same regardless of whether the chromatic layer was present, absent, or phase-scrambled; in other words, the chromatic layer, in whatever form, did not affect sensitivity to the luminance layer distortion. However, when the chromatic layer was distorted, sensitivity was higher when the luminance layer was intact compared to when absent or phase-scrambled. These detection threshold results complement the appearance of periodic distortions of the image scale: when the luminance layer is distorted visibly, the scene appears distorted, but when the chromatic layer is distorted visibly, there is little apparent scene distortion. We conclude that (a) observers have a built-in sense of how a normal image of a natural scene should appear, and (b) the detection of distortion in, as well as the apparent distortion of, natural scene images is mediated predominantly by the luminance layer and not chromatic layer.

  18. A Receptor-Based Explanation for Tsetse Fly Catch Distribution between Coloured Cloth Panels and Flanking Nets

    PubMed Central

    Santer, Roger D.

    2015-01-01

    Tsetse flies transmit trypanosomes that cause nagana in cattle, and sleeping sickness in humans. Therefore, optimising visual baits to control tsetse is an important priority. Tsetse are intercepted at visual baits due to their initial attraction to the bait, and their subsequent contact with it due to landing or accidental collision. Attraction is proposed to be driven in part by a chromatic mechanism to which a UV-blue photoreceptor contributes positively, and a UV and a green photoreceptor contribute negatively. Landing responses are elicited by stimuli with low luminance, but many studies also find apparently strong landing responses when stimuli have high UV reflectivity, which would imply that UV wavelengths contribute negatively to attraction at a distance, but positively to landing responses at close range. The strength of landing responses is often judged using the number of tsetse sampled at a cloth panel expressed as a proportion of the combined catch of the cloth panel and a flanking net that samples circling flies. I modelled these data from two previously published field studies, using calculated fly photoreceptor excitations as predictors. I found that the proportion of tsetse caught on the cloth panel increased with an index representing the chromatic mechanism driving attraction, as would be expected if the same mechanism underlay both long- and close-range attraction. However, the proportion of tsetse caught on the cloth panel also increased with excitation of the UV-sensitive R7p photoreceptor, in an apparently separate but interacting behavioural mechanism. This R7p-driven effect resembles the fly open-space response which is believed to underlie their dispersal towards areas of open sky. As such, the proportion of tsetse that contact a cloth panel likely reflects a combination of deliberate landings by potentially host-seeking tsetse, and accidental collisions by those seeking to disperse, with a separate visual mechanism underlying each behaviour. PMID:26474406

  19. Potential of Silanes for Chromate Replacement in Metal Finishing Industries

    DTIC Science & Technology

    2002-09-16

    POTENTIAL OF SILANES FOR CHROMATE REPLACEMENT IN METAL FINISHING INDUSTRIES Wim J. van Ooij*, Danqing Zhu, Vignesh Palanivel, J. Anna Lamar...18 2 POTENTIAL OF SILANES FOR CHROMATE REPLACEMENT IN METAL FINISHING INDUSTRIES Wim J. van Ooij, Danqing Zhu, Vignesh Palanivel, J. Anna Lamar

  20. Single bunch transverse instability in a circular accelerator with chromaticity and space charge

    DOE PAGES

    Balbekov, V.

    2015-10-21

    The transverse instability of a bunch in a circular accelerator is elaborated in this paper. A new tree-modes model is proposed and developed to describe the most unstable modes of the bunch. This simple and flexible model includes chromaticity and space charge, and can be used with any bunch and wake forms. The dispersion equation for the bunch eigentunes is obtained in form of a third-order algebraic equation. The known head-tail and TMCI modes appear as the limiting cases which are distinctly bounded at zero chromaticity only. It is shown that the instability parameters depend only slightly on the bunchmore » model but they are rather sensitive to the wake shape. In particular, space charge effects are investigated in the paper and it is shown that their influence depends on sign of wake field enhancing the bunch stability if the wake is negative. In addition, the resistive wall wake is considered in detail including a comparison of single and collective effects. A comparison of the results with earlier publications is carried out.« less

  1. Chromaticity effects on head-tail instabilities for broadband impedance using two particle model, Vlasov analysis, and simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chin, Yong Ho; Chao, Alexander Wu; Blaskiewicz, Michael M.

    Effects of the chromaticity on head-tail instabilities for broadband impedances are comprehensively studied, using the two particle model, the Vlasov analysis and computer simulations. We show both in the two particle model and the Vlasov analysis with the trapezoidal (semiconstant) wake model that we can derive universal contour plots for the growth factor as a function of the two dimensionless parameters: the wakefield strength, Υ, and the difference of the betatron phase advances between the head and the tail, χ. They reveal how the chromaticity affects strong head-tail instabilities and excites head-tail instabilities. We also apply the LEP (Large Electron-Positronmore » Collider) broadband resonator model to the Vlasov approach and find that the results are in very good agreement with those of the trapezoidal wake model. The theoretical findings are also reinforced by the simulation results. In conclusion, the trapezoidal wake model turns out to be a very useful tool since it significantly simplifies the time domain analysis and provides well-behaved impedance at the same time.« less

  2. Chromaticity effects on head-tail instabilities for broadband impedance using two particle model, Vlasov analysis, and simulations

    DOE PAGES

    Chin, Yong Ho; Chao, Alexander Wu; Blaskiewicz, Michael M.; ...

    2017-07-28

    Effects of the chromaticity on head-tail instabilities for broadband impedances are comprehensively studied, using the two particle model, the Vlasov analysis and computer simulations. We show both in the two particle model and the Vlasov analysis with the trapezoidal (semiconstant) wake model that we can derive universal contour plots for the growth factor as a function of the two dimensionless parameters: the wakefield strength, Υ, and the difference of the betatron phase advances between the head and the tail, χ. They reveal how the chromaticity affects strong head-tail instabilities and excites head-tail instabilities. We also apply the LEP (Large Electron-Positronmore » Collider) broadband resonator model to the Vlasov approach and find that the results are in very good agreement with those of the trapezoidal wake model. The theoretical findings are also reinforced by the simulation results. In conclusion, the trapezoidal wake model turns out to be a very useful tool since it significantly simplifies the time domain analysis and provides well-behaved impedance at the same time.« less

  3. A double-blind, placebo-controlled study on the effects of lutein and zeaxanthin on photostress recovery, glare disability, and chromatic contrast.

    PubMed

    Hammond, Billy R; Fletcher, Laura M; Roos, Franz; Wittwer, Jonas; Schalch, Wolfgang

    2014-12-02

    Past studies have shown that higher macular pigment optical density (MPOD) and lutein (L) and zeaxanthin (Z) supplementation are related to improvements in glare disability, photostress recovery, and chromatic contrast. This study assessed those links using a randomized, double-blind, placebo-controlled design. The visual effects of 1 year of supplementing L (10 mg/d) and Z (2 mg/d) were investigated. One hundred fifteen young, healthy subjects were recruited and randomized into the study (58 received placebo, 57 L+Z). Several dependent measures were collected at baseline and then once every 3 months: serum L and Z measured by HPLC chromatography; MPOD measured using customized heterochromatic flicker photometry; photostress recovery assessed by measuring the time needed to recover visual acquisition of a grating target after 30 seconds of an intense xenon white flash exposure; glare disability evaluated as the energy in a surrounding annulus necessary to veil a central grating target; and chromatic contrast assessed by measuring thresholds for a yellow grating target superposed on a 460-nm background. Macular pigment optical density increased significantly versus placebo at all eccentricities (10, 30, 60, and 105 minutes from the center of the macula). Serum L and Z also increased significantly by the first follow-up visit (at 3 months), and remained elevated throughout the intervention period of 1 year. Chromatic contrast and photostress recovery time improved significantly versus placebo. Glare disability was correlated with macular pigment density throughout the study period but did not increase significantly in the treated group. Daily supplementation with L+Z resulted in significant increase in serum levels and MPOD and improvements in chromatic contrast and recovery from photostress. These results are consistent with past studies showing that increasing MPOD leads to improved visual performance. (ClinicalTrials.gov number, NCT00909090.). Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  4. Fast online simultaneous monitoring of PMD and chromatic dispersion with reduced polarization dependent gain

    NASA Astrophysics Data System (ADS)

    Ning, G.; Shum, P.; Aditya, S.; Gong, Yandong

    2006-09-01

    We use the expression relating the output state of polarization and PMD vector. Based on this expression we get the power fading including first-order PMD and chromatic dispersion, which is dependent on the angle of precession of output state of polarization around the PMD vector. From the expression for power fading, we get the average power penalty for chromatic dispersion and PMD. We propose a novel and fast PMD and chromatic dispersion monitoring technology. Measured results agree well with theoretical analysis.

  5. Symplectic maps and chromatic optics in particle accelerators

    DOE PAGES

    Cai, Yunhai

    2015-07-06

    Here, we have applied the nonlinear map method to comprehensively characterize the chromatic optics in particle accelerators. Our approach is built on the foundation of symplectic transfer maps of magnetic elements. The chromatic lattice parameters can be transported from one element to another by the maps. We also introduce a Jacobian operator that provides an intrinsic linkage between the maps and the matrix with parameter dependence. The link allows us to directly apply the formulation of the linear optics to compute the chromatic lattice parameters. As an illustration, we analyze an alternating-gradient cell with nonlinear sextupoles, octupoles, and decapoles andmore » derive analytically their settings for the local chromatic compensation. Finally, the cell becomes nearly perfect up to the third-order of the momentum deviation.« less

  6. Very-long-term and short-term chromatic adaptation: are their influences cumulative?

    PubMed

    Belmore, Suzanne C; Shevell, Steven K

    2011-02-09

    Very-long-term (VLT) chromatic adaptation results from exposure to an altered chromatic environment for days or weeks. Color shifts from VLT adaptation are observed hours or days after leaving the altered environment. Short-term chromatic adaptation, on the other hand, results from exposure for a few minutes or less, with color shifts measured within seconds or a few minutes after the adapting light is extinguished; recovery to the pre-adapted state is complete in less than an hour. Here, both types of adaptation were combined. All adaptation was to reddish-appearing long-wavelength light. Shifts in unique yellow were measured following adaptation. Previous studies demonstrate shifts in unique yellow due to VLT chromatic adaptation, but shifts from short-term chromatic adaptation to comparable adapting light can be far greater than from VLT adaptation. The question considered here is whether the color shifts from VLT adaptation are cumulative with large shifts from short-term adaptation or, alternatively, does simultaneous short-term adaptation eliminate color shifts caused by VLT adaptation. The results show the color shifts from VLT and short-term adaptation together are cumulative, which indicates that both short-term and very-long-term chromatic adaptation affect color perception during natural viewing. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Polydiacetylene chromism towards toxic chemical detection via molecular size-dependent selectivity

    NASA Astrophysics Data System (ADS)

    Seo, Donghwan

    Polydiacetylene (PDA) is a pi-conjugated polymer that has unique optical properties. PDA changes color from blue to red when subjected to various stimuli such as mechanical stress, heat, photoirradiation, pH change, and binding of specific ligands. The steric effect induced by those stimuli on PDA headgroup has been investigated to understand the mechanism of PDA chromism and to apply those optical properties to the development of various sensors. In this work, pH chromism of PDA was examined in terms of the effects of the molecular size and acidity of acid analytes with the consideration of the molecular design aspect of diacetylene lipids. The pH level is an important parameter, since a low pH will produce a charge on the amine headgroup of PDA, but this does not necessarily result in PDA chromatic transition from 'blue phase' to 'red phase.' The molecular size of the counter anion was identified as another determinant condition to ensure the perturbation of the ene-yne conjugated backbone of PDA, which produces the chromatic transition. In the molecular design of the sensory diacetylene lipids, the alkyl spacer length between the amine as a receptor and the amide linker was found to strongly affect the degree of PDA chromatic transition. The longer alkyl spacer showed the less chromatic transition. The length of alkyl spacer seems to promote the flexibility of the molecule diminishing the extent of the transfer of the steric effect at PDA headgroup to the conjugated backbone. Finally, PDA chromism dependent on the molecular size of acid analytes was applied to develop the colorimetric detection of diethyl phosphate (DEP), a degraded nerve agent simulant. PDA liposome sensors successfully showed selective chromatic transition with fluorescent emission upon binding of DEP compared to other acid analytes. The molecular size and acidity of acid analytes, and alkyl spacer length have proven to be correlated with PDA chromism. These new findings provide further understanding of the mechanism of PDA chromism and the molecular design principle of diacetylene in fundamental studies and in the development of various applications.

  8. Hexavalent Chromium Causes the Oxidation of Thioredoxin in Human Bronchial Epithelial Cells

    PubMed Central

    Myers, Judith M.; Antholine, William E.; Myers, Charles R.

    2008-01-01

    Hexavalent chromium [Cr(VI)] species such as chromates are cytotoxic. Inhalational exposure is a primary concern in many Cr-related industries and their immediate environments, and bronchial epithelial cells are directly exposed to inhaled Cr(VI). Chromates are readily taken up by cells and are reduced to reactive Cr species which may also result in the generation of reactive oxygen species (ROS). The thioredoxin (Trx) system has a key role in the maintenance of cellular thiol redox balance and is essential for cell survival. Cells normally maintain the cytosolic (Trx1) and mitochondrial (Trx2) thioredoxins largely in the reduced state. Redox western blots were used to assess the redox status of the thioredoxins in normal human bronchial epithelial cells (BEAS-2B) incubated with soluble Na2CrO4 or insoluble ZnCrO4 for different periods of time. Both chromates caused a dose- and time-dependent oxidation of Trx2 and Trx1. Trx2 was more susceptible in that it could all be converted to the oxidized form, whereas a small amount of reduced Trx1 remained even after prolonged treatment with higher Cr concentrations. Only one of the dithiols, presumably the active site, of Trx1 was oxidized by Cr(VI). Cr(VI) did not cause significant GSH depletion or oxidation indicating that Trx oxidation does not result from a general oxidation of cellular thiols. With purified Trx and thioredoxin reductase (TrxR) in vitro, Cr(VI) also resulted in Trx oxidation. It was determined that purified TrxR has pronounced Cr(VI) reducing activity, so competition for electron flow from TrxR might impair its ability to reduce Trx. The in vitro data also suggested some direct redox interaction between Cr(VI) and Trx. The ability of Cr(VI) to cause Trx oxidation in cells could contribute to its cytotoxic effects, and could have important implications for cell survival, redox-sensitive cell signaling, and the cells' tolerance of other oxidant insults. PMID:18328613

  9. Effects of metal compounds with distinct physicochemical properties on iron homeostasis and antibacterial activity in the lungs: chromium and vanadium.

    PubMed

    Cohen, Mitchell D; Sisco, Maureen; Prophete, Colette; Yoshida, Kotaro; Chen, Lung-chi; Zelikoff, Judith T; Smee, Jason; Holder, Alvin A; Stonehuerner, Jacqueline; Crans, Debbie C; Ghio, Andrew J

    2010-02-01

    In situ reactions of metal ions or their compounds are important mechanisms by which particles alter lung immune responses. The authors hypothesized that major determinants of the immunomodulatory effect of any metal include its redox behavior/properties, oxidation state, and/or solubility, and that the toxicities arising from differences in physicochemical parameters are manifest, in part, via differential shifts in lung iron (Fe) homeostasis. To test the hypotheses, immunomodulatory potentials for both pentavalent vanadium (VV; as soluble metavanadate or insoluble vanadium pentoxide) and hexavalent chromium (CrVI; as soluble sodium chromate or insoluble calcium chromate) were quantified in rats after inhalation (5h/day for 5 days) of each at 100 microg metal/m3. Differences in effects on local bacterial resistance between the two VV, and between each CrVI, agents suggested that solubility might be a determinant of in situ immunotoxicity. For the soluble forms, VV had a greater impact on resistance than CrVI, indicating that redox behavior/properties was likely also a determinant. The soluble VV agent was the strongest immunomodulant. Regarding Fe homeostasis, both VV agents had dramatic effects on airway Fe levels. Both also impacted local immune/airway epithelial cell Fe levels in that there were significant increases in production of select cytokines/chemokines whose genes are subject to regulation by HIF-1 (whose intracellular longevity is related to cell Fe status). Our findings contribute to a better understanding of the role that metal compound properties play in respiratory disease pathogenesis and provide a rationale for differing pulmonary immunotoxicities of commonly encountered ambient metal pollutants.

  10. The influence of L-opsin gene polymorphisms and neural ageing on spatio-chromatic contrast sensitivity in 20-71 year olds.

    PubMed

    Dees, Elise W; Gilson, Stuart J; Neitz, Maureen; Baraas, Rigmor C

    2015-11-01

    Chromatic contrast sensitivity may be a more sensitive measure of an individual's visual function than achromatic contrast sensitivity. Here, the first aim was to quantify individual- and age-related variations in chromatic contrast sensitivity to a range of spatial frequencies for stimuli along two complementary directions in color space. The second aim was to examine whether polymorphisms at specific amino acid residues of the L- and M-opsin genes (OPN1LW and OPN1MW) known to affect spectral tuning of the photoreceptors could influence spatio-chromatic contrast sensitivity. Chromatic contrast sensitivity functions were measured in 50 healthy individuals (20-71 years) employing a novel pseudo-isochromatic grating stimulus. The spatio-chromatic contrast sensitivity functions were found to be low pass for all subjects, independent of age and color vision. The results revealed a senescent decline in spatio-chromatic contrast sensitivity. There were considerable between-individual differences in sensitivity within each age decade for individuals 49 years old or younger, and age did not predict sensitivity for these age decades alone. Forty-six subjects (including a color deficient male and eight female carriers) were genotyped for L- and M-opsin genes. The Ser180Ala polymorphisms on the L-opsin gene were found to influence the subject's color discrimination and their sensitivity to spatio-chromatic patterns. The results expose the significant role of neural and genetic factors in the deterioration of visual function with increasing age. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Fluctuations in the prevalence of chromate allergy in Denmark and exposure to chrome-tanned leather.

    PubMed

    Carøe, Caroline; Andersen, Klaus E; Thyssen, Jacob P; Mortz, Charlotte G

    2010-12-01

    A recent Danish study showed a significant increase in the prevalence of chromate contact allergy after the mid-1990s, probably as a result of exposure to leather products. To reproduce the results by analysing data from the period 1992-2009 at Odense University Hospital, Denmark. The temporal development in the occurrence of chromate contact allergy and assumed causative exposures were investigated. A retrospective analysis of patch test data was performed (n = 8483), and medical charts from patients with chromate allergy (n = 231) were reviewed. Comparisons were made using the χ(2) -test. A test of the reproducibility of the TRUE Test® was also performed. Logistic regression analyses were used to test for associations. No significant changes in the prevalence or exposure sources of chromate allergy during 1992-2009 were identified. Leather shoes (24.4%) were the most frequent exposure sources in chromate allergy, and were mainly registered in women, although the difference between men and women was not significant (P = 0.07). Cement and leather glove exposure occurred significantly more often in men than in women (P = 0.002). Foot dermatitis (40.3%) was the most frequent anatomical location, apart from hand eczema (60.6%). The reproducibility of the TRUE Test® was 93.3%. Apart from hand eczema, the most frequent clinical picture of chromate allergy was foot dermatitis caused by leather shoe exposure. A tendency for an increasing prevalence of chromate contact allergy from 1997 was shown, but no significant change was detectable. © 2010 John Wiley & Sons A/S.

  12. Staging optics considerations for a plasma wakefield acceleration linear collider

    NASA Astrophysics Data System (ADS)

    Lindstrøm, C. A.; Adli, E.; Allen, J. M.; Delahaye, J. P.; Hogan, M. J.; Joshi, C.; Muggli, P.; Raubenheimer, T. O.; Yakimenko, V.

    2016-09-01

    Plasma wakefield acceleration offers acceleration gradients of several GeV/m, ideal for a next-generation linear collider. The beam optics requirements between plasma cells include injection and extraction of drive beams, matching the main beam beta functions into the next cell, canceling dispersion as well as constraining bunch lengthening and chromaticity. To maintain a high effective acceleration gradient, this must be accomplished in the shortest distance possible. A working example is presented, using novel methods to correct chromaticity, as well as scaling laws for a high energy regime.

  13. TRACKING SIMULATIONS NEAR HALF-INTEGER RESONANCE AT PEP-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nosochkov, Yuri

    2003-05-13

    Beam-beam simulations predict that PEP-II luminosity can be increased by operating the horizontal betatron tune near and above a half-integer resonance. However, effects of the resonance and its synchrotron sidebands significantly enhance betatron and chromatic perturbations which tend to reduce dynamic aperture. In the study, chromatic variation of horizontal tune near the resonance was minimized by optimizing local sextupoles in the Interaction Region. Dynamic aperture was calculated using tracking simulations in LEGO code. Dependence of dynamic aperture on the residual orbit, dispersion and {beta} distortion after correction was investigated.

  14. Cr-Free Metallic-Ceramic Coatings

    DTIC Science & Technology

    2014-11-01

    Comparable to Aluminum-Chromate/ Phosphate Humidity Resistance Galvanic Corrosion Resistance Nov. 2014 ASETSDefense 2014, Fort Myer, VA...Aluminum-Silicate Comparable to Aluminum-Chromate/ Phosphate  Humidity, Galvanic Corrosion , Heat/Salt Resistance  Adhesion & Compatibility...WP-TR-2007-4069, Sept. 2006 Sealed Aluminum-Silicate Not Comparable to Sealed Aluminum-Chromate/ Phosphate in PEWG Evaluation  Corrosion

  15. Cortical Double-Opponent Cells in Color Perception: Perceptual Scaling and Chromatic Visual Evoked Potentials.

    PubMed

    Nunez, Valerie; Shapley, Robert M; Gordon, James

    2018-01-01

    In the early visual cortex V1, there are currently only two known neural substrates for color perception: single-opponent and double-opponent cells. Our aim was to explore the relative contributions of these neurons to color perception. We measured the perceptual scaling of color saturation for equiluminant color checkerboard patterns (designed to stimulate double-opponent neurons preferentially) and uniformly colored squares (designed to stimulate only single-opponent neurons) at several cone contrasts. The spatially integrative responses of single-opponent neurons would produce the same response magnitude for checkerboards as for uniform squares of the same space-averaged cone contrast. However, perceived saturation of color checkerboards was higher than for the corresponding squares. The perceptual results therefore imply that double-opponent cells are involved in color perception of patterns. We also measured the chromatic visual evoked potential (cVEP) produced by the same stimuli; checkerboard cVEPs were much larger than those for corresponding squares, implying that double-opponent cells also contribute to the cVEP response. The total Fourier power of the cVEP grew sublinearly with cone contrast. However, the 6-Hz Fourier component's power grew linearly with contrast-like saturation perception. This may also indicate that cortical coding of color depends on response dynamics.

  16. Cortical Double-Opponent Cells in Color Perception: Perceptual Scaling and Chromatic Visual Evoked Potentials

    PubMed Central

    Shapley, Robert M.; Gordon, James

    2018-01-01

    In the early visual cortex V1, there are currently only two known neural substrates for color perception: single-opponent and double-opponent cells. Our aim was to explore the relative contributions of these neurons to color perception. We measured the perceptual scaling of color saturation for equiluminant color checkerboard patterns (designed to stimulate double-opponent neurons preferentially) and uniformly colored squares (designed to stimulate only single-opponent neurons) at several cone contrasts. The spatially integrative responses of single-opponent neurons would produce the same response magnitude for checkerboards as for uniform squares of the same space-averaged cone contrast. However, perceived saturation of color checkerboards was higher than for the corresponding squares. The perceptual results therefore imply that double-opponent cells are involved in color perception of patterns. We also measured the chromatic visual evoked potential (cVEP) produced by the same stimuli; checkerboard cVEPs were much larger than those for corresponding squares, implying that double-opponent cells also contribute to the cVEP response. The total Fourier power of the cVEP grew sublinearly with cone contrast. However, the 6-Hz Fourier component’s power grew linearly with contrast-like saturation perception. This may also indicate that cortical coding of color depends on response dynamics. PMID:29375753

  17. Accommodative performance for chromatic displays.

    PubMed

    Lovasik, J V; Kergoat, H

    1988-01-01

    Over the past few years, video display units (VDUs) have been incorporated into many varieties of workplaces and occupational demands. The success of electro-optical displays in facilitating and improving job performance has spawned interest in extracting further advantage from VDUs by incorporating colour coding into such communication systems. However, concerns have been raised about the effect of chromatic stimuli on the visual comfort and task efficiency, because of the chromatic aberration inherent in the optics of the human eye. In this study, we used a computer aided laser speckle optometer system to measure the accommodative responses to brightness-matched chromatic letters displayed on a high-resolution RGB monitor. Twenty, visually normal, paid volunteers in a 22-35 year age category served as subjects. Stimuli were 14, 21, 28 minutes of arc letters presented in a 'monochromatic' (white, red, green or blue, on a black background) or 'multichromatic' (blue-red, blue-green, red-green, foreground-background combinations) mode at 40 and 80 cm viewing distances. The results demonstrated that while the accommodative responses were strongly influenced by the foreground-background colour combination, the group-averaged dioptric difference across colours was relatively small. Further, accommodative responses were not guided in any systematic fashion by the size of letters presented for fixation. Implications of these findings for display designs are discussed.

  18. Patch test reactivity to metal allergens following regulatory interventions: a 33-year retrospective study.

    PubMed

    Thyssen, Jacob Pontoppidan; Ross-Hansen, Katrine; Menné, Torkil; Johansen, Jeanne Duus

    2010-08-01

    Contact allergy epidemics to chromate and nickel were addressed in Denmark in 1983 and 1990 by regulatory interventions. To evaluate whether regulatory interventions on nickel and chromate exposure have reduced the proportion of strong patch test reactions. 22 506 patients with dermatitis aged 4-99 years were patch tested with nickel sulfate, potassium dichromate, or cobalt chloride between 1977 and 2009. The proportion of 3+ reactions to nickel sulfate was reduced and almost disappeared after the mid- and late 1980s (P-trend = 0.001). Today, 1+ and 2+ nickel reactions occur equally frequent. Cobalt chloride patch test reactivity reflected the nickel development to some degree. The proportion of 3+ reactions to potassium dichromate was reduced during the 1980s (P-trend = 0.13), whereas the proportion of 2+ reactions to potassium dichromate have increased in recent years. The decrease in nickel sulfate and cobalt chloride 3+ patch test reactivity began long before the Danish nickel regulation came into effect. This could be because of research activity at the time as well as political attention in Northern Europe. The chromate content in cement regulation may have changed the epidemiology of patch test reactivity; however, in recent years, 2+ reactions to chromate have increased markedly, a development that should be carefully followed.

  19. [Effect of five kinds of pigments on the chromaticity of dental zirconia ceramic].

    PubMed

    Huang, Hui; Zheng, Yuan-li; Zhang, Fu-qiang; Sun, Jing; Gao, Lian

    2007-08-01

    All-ceramic dental restorations should match the colour of the natural teeth in order to fulfill aesthetic demands. The goal of this study was to evaluate the colouration of zirconia ceramic by adding five kinds of pigments. The influence of the pigments concentrations on the chromaticity were also analysed. Different concentrations of five kinds of pigments were added on zirconia powder, then compacted at 200MPa using cold isostatic pressure, sintered to 1400 degrees centigrade and hold for two hours. The chromaticity of sintered bodies were measured with chroma meter. The colours achieved by the different pigments were presented in the CIELab system. The a* value increased with the added amount of Er(2)O(3), while b* value raised with the increasing amount of CeO(2) and Pr(6)O(11). However, three pigments failed to decrease L* value and the sintered body looked too bright. The sintered bodies were brown when adding Fe(2)O(3) to zirconia. Adding MnO2 could decrease the L* value of sintered bodies significantly, but had little influence on the a* and b* value. Five kinds of colorized zirconia ceramic could cover with the chromaticity range of dental ceramic which necessitate further investigation.

  20. In vivo chromatic aberration in eyes implanted with intraocular lenses.

    PubMed

    Pérez-Merino, Pablo; Dorronsoro, Carlos; Llorente, Lourdes; Durán, Sonia; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2013-04-12

    To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL). EIGHTEEN EYES PARTICIPATED IN THIS STUDY: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 ± 0.15 diopters (D) in the Tecnis group, and 0.75 ± 0.12 D in the AcrySof group, and the difference was statistically significant (P < 0.05). Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 ± 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in young eyes.

  1. Identification of polymer stabilized blue-phase liquid crystal display by chromaticity diagram

    NASA Astrophysics Data System (ADS)

    Lan, Yi-Fen; Tsai, Cheng-Yeh; Wang, Ling-Yung; Ku, Po-Jen; Huang, Tai-Hsiang; Liu, Chu-Yu; Sugiura, Norio

    2012-04-01

    We reported an identification method of blue phase liquid crystal (BPLC) display status by using Commission International de l'Éclairage (CIE) chromaticity diagram. The BPLC was injected into in-plane-switch (IPS) cell, polymer stabilized (PS) by ultraviolet cured process and analyzed by luminance colorimeter. The results of CIE chromaticity diagram showed a remarkable turning point when polymer stabilized blue phase liquid crystal II (PSBPLC-II) formed in the IPS cell. A mechanism of CIE chromaticity diagram identify PSBPLC display status was proposed, and we believe this finding will be useful to application and production of PSBPLC display.

  2. Binocular interactions in random chromatic changes at isoluminance

    NASA Astrophysics Data System (ADS)

    Medina, José M.

    2006-02-01

    To examine the type of chromatic interactions at isoluminance in the phenomenon of binocular vision, I have determined simple visual reaction times (VRT) under three observational conditions (monocular left, monocular right, and binocular) for different chromatic stimuli along random color axes at isoluminance (simultaneous L-, M-, and S-cone variations). Upper and lower boundaries of probability summation as well as the binocular capacity coefficient were estimated with observed distributions of reaction times. The results were not consistent with the notion of independent chromatic channels between eyes, suggesting the existence of excitatory and inhibitory binocular interactions at suprathreshold isoluminance conditions.

  3. Chromatic interocular-switch rivalry.

    PubMed

    Christiansen, Jens H; D'Antona, Anthony D; Shevell, Steven K

    2017-05-01

    Interocular-switch rivalry (also known as stimulus rivalry) is a kind of binocular rivalry in which two rivalrous images are swapped between the eyes several times a second. The result is stable periods of one image and then the other, with stable intervals that span many eye swaps (Logothetis, Leopold, & Sheinberg, 1996). Previous work used this close kin of binocular rivalry with rivalrous forms. Experiments here test whether chromatic interocular-switch rivalry, in which the swapped stimuli differ in only chromaticity, results in slow alternation between two colors. Swapping equiluminant rivalrous chromaticities at 3.75 Hz resulted in slow perceptual color alternation, with one or the other color often continuously visible for two seconds or longer (during which there were 15+ eye swaps). A well-known theory for sustained percepts from interocular-switch rivalry with form is inhibitory competition between binocular neurons driven by monocular neurons with matched orientation tuning in each eye; such binocular neurons would produce a stable response when a given orientation is swapped between the eyes. A similar model can account for the percepts here from chromatic interocular-switch rivalry and is underpinned by the neurophysiological finding that color-preferring binocular neurons are driven by monocular neurons from each eye with well-matched chromatic selectivity (Peirce, Solomon, Forte, & Lennie, 2008). In contrast to chromatic interocular-switch rivalry, luminance interocular-switch rivalry with swapped stimuli that differ in only luminance did not result in slowly alternating percepts of different brightnesses.

  4. Effects of optical layer impairments on 2.5 Gb/s optical CDMA transmission.

    PubMed

    Feng, H; Mendez, A; Heritage, J; Lennon, W

    2000-07-03

    We conducted a computer simulation study to assess the effects of optical layer impairments on optical CDMA (O-CDMA) transmission of 8 asynchronous users at 2.5 Gb/s each user over a 214-km link. It was found that with group velocity dispersion compensation, two other residual effects, namely, the nonzero chromatic dispersion slope of the single mode fiber (which causes skew) and the non-uniform EDFA gain (which causes interference power level to exceed signal power level of some codes) degrade the signal to multi-access interference (MAI) ratio. In contrast, four wave mixing and modulation due to the Kerr and Raman contributions to the fiber nonlinear refractive index are less important. Current wavelength-division multiplexing (WDM) technologies, including dispersion management, EDFA gain flattening, and 3 rd order dispersion compensation, are sufficient to overcome the impairments to the O-CDMA transmission system that we considered.

  5. In vivo longitudinal chromatic aberration of pseudophakic eyes.

    PubMed

    Siedlecki, Damian; Jóźwik, Agnieszka; Zając, Marek; Hill-Bator, Aneta; Turno-Kręcicka, Anna

    2014-02-01

    To present the results of longitudinal chromatic aberration measurements on two groups of pseudophakic eyes in comparison to healthy eyes. The longitudinal chromatic aberration of the eye, defined as chromatic difference of refraction with disabled accommodation, was measured with the use of a visual refractometer with a custom-designed target illuminator consisting of a narrow-band RGB diode (blue λb = 470 ± 15 nm; green λg = 525 ± 18 nm; red λr = 660 ± 10 nm). The measurements were performed on nine eyes implanted with AcrySof IQ SN60WF, 14 eyes implanted with AcrySof SA60AT, and 10 phakic eyes under cycloplegia. The mean values of the longitudinal chromatic aberration between 470 and 660 nm for the control group was 1.12 ± 0.14 D. For SA60AT group, it was 1.45 ± 0.42 D whereas for SN60WF it was 1.17 ± 0.52 D. The statistical test showed significant difference between SA60AT and the control group (p < 0.05) and no significant difference between SN60WF and the control groups (p = 0.64). The study showed that the longitudinal chromatic aberration in vivo can be easily and reliably estimated with an adapted visual refractometer. The two groups of pseudophakic eyes measured in this study showed different values of chromatic aberration. Its magnitude for SA60AT group was significantly larger than for the control group whereas for SN60WF the difference was not significant. The optical material used for intraocular lens design may have significant influence on the magnitude of the chromatic aberration of the pseudophakic eye, and therefore on its optical and visual performance in polychromatic light.

  6. Pupillometer-based objective chromatic perimetry in normal eyes and patients with retinal photoreceptor dystrophies.

    PubMed

    Skaat, Alon; Sher, Ifat; Kolker, Andrew; Elyasiv, Sivan; Rosenfeld, Elkana; Mhajna, Mohamad; Melamed, Shlomo; Belkin, Michael; Rotenstreich, Ygal

    2013-04-17

    To evaluate a novel objective perimetry using multifocal chromatic pupil light reflex in normal participants and patients with photoreceptor dysfunction, and to relate this new technique with subjective dark-adapted chromatic Goldmann perimetry. Thirty-two eyes of 17 retinitis pigmentosa (RP) or cone-rod dystrophy patients and 20 eyes of 12 healthy individuals were tested. A computerized infrared video pupillometer was used to record changes in pupil diameter in response to short- and long-wavelength stimuli (peak 485 and 640 nm, respectively; light intensity 40 cd/m(2)) at 13 different points of the 30° visual field (VF), under background illumination of 2.7 cd/m(2). The pupillary response (PR) of patients was compared with PR obtained from normal control participants. In 11 patients, the pupillary responses were also compared with their findings on dark-adapted chromatic Goldmann perimetry. Significantly reduced pupillary responses were obtained in RP patients in response to the short-wavelength stimulus in nearly all perimetric locations (P < 0.03). By contrast, in response to the long-wavelength stimulus, RP patients demonstrated significantly reduced PR mostly in peripheral locations (P ≤ 0.02). In a cone-rod dystrophy patient, the PR to both long- and short-wavelength stimuli was significantly lower in the scotoma area identified by the dark-adapted chromatic Goldmann perimetry. In all patients that were tested by the chromatic Goldmann, minimal PR was recorded in areas that were nondetected in the chromatic Goldmann perimetry. This study demonstrates the potential feasibility of using pupillometer-based chromatic perimetry for objectively assessing VF defects and retinal function in patients with retinal dystrophies. (ClinicalTrials.gov number, NCT01021982.).

  7. On the r-dynamic chromatic number of the corronation by complete graph

    NASA Astrophysics Data System (ADS)

    Indah Kristiana, Arika; Imam Utoyo, M.; Dafik

    2018-04-01

    In this paper we will study the r-dynamic chromatic number of the coronation by complete graph. A proper k-coloring of graph G such that the neighbors of any vertex v receive at least min{r, d(v)} different colors. The r-dynamic chromatic number, χ r (G) is the minimum k such that graph G has an r-dynamic k-coloring. We will obtain lower bound of the r-dynamic chromatic number of {χ }r({K}nȯ H), and {χ }r(Hȯ {K}m) We also study the exact value of the r-dynamic chromatic number of {χ }r({K}nȯ {S}m),{χ }r({K}nȯ {F}m),{χ }r({S}nȯ {K}m),{χ }r({F}nȯ {K}m) and {χ }r({K}nȯ {K}m) for m, n > 3.

  8. Determination of the chromatic dispersion of liquids based on the liquid-prism SPR configuration in angular and spectral interrogations

    NASA Astrophysics Data System (ADS)

    Lan, Guoqiang; Liu, Shugang; Wang, Yuxiao; Zhang, Xueru; Song, Yinglin

    2015-10-01

    In this work, we use the liquid-prism SPR sensing configuration to determine the chromatic dispersion of different liquids, since the condition of SPR is sensitive to the refractive index of the liquid prism. We use the glass slide coated with 50 nm Au film as the sensing chip, and use AvaLight - HAL (360 nm - 2500 nm) light source as the broaden band light source in our experiments. We adopt the deionized water as the standard sample to determine the chromatic dispersion of different liquid samples (ethanol and n-hexane), and we implement the experiment through the SPR sensing configuration in angular and spectral interrogations. According to the experimental data, the chromatic dispersions of ethanol and n-hexane are obtained. The proposed technique provides a new high sensitive method for the determination of chromatic dispersion of liquids.

  9. Effects of soluble and particulate Cr(VI) on genome-wide DNA methylation in human B lymphoblastoid cells.

    PubMed

    Lou, Jianlin; Wang, Yu; Chen, Junqiang; Ju, Li; Yu, Min; Jiang, Zhaoqiang; Feng, Lingfang; Jin, Lingzhi; Zhang, Xing

    2015-10-01

    Several previous studies highlighted the potential epigenetic effects of Cr(VI), especially DNA methylation. However, few studies have compared the effects of Cr(VI) on DNA methylation profiles between soluble and particulate chromate in vitro. Accordingly, Illumina Infinium Human Methylation 450K BeadChip array was used to analyze DNA methylation profiles of human B lymphoblastoid cells exposed to potassium dichromate or lead chromate, and the cell viability was also studied. Array based DNA methylation analysis showed that the impacts of Cr(VI) on DNA methylation were limited, only about 40 differentially methylated CpG sites, with an overlap of 15CpG sites, were induced by both potassium dichromate and lead chromate. The results of mRNA expression showed that after Cr(VI) treatment, mRNA expression changes of four genes (TBL1Y, FZD5, IKZF2, and KIAA1949) were consistent with their DNA methylation alteration, but DNA methylation changes of other six genes did not correlate with mRNA expression. In conclusion, both of soluble and particulate Cr(VI) could induce a small amount of differentially methylated sites in human B lymphoblastoid cells, and the correlations between DNA methylation changes and mRNA expression varied between different genes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Spectral mechanisms of spatially induced blackness: data and quantitative model.

    PubMed

    Shinomori, K; Schefrin, B E; Werner, J S

    1997-02-01

    Spectral efficiency functions and tests of additivity were obtained with three observers to identify possible chromatic contributions to spatially induced blackness. Stimuli consisted of a series of monochromatic (400-700 nm; 10-nm steps), 52-arcmin circular test lights surrounded by broadband (x = 0.31, y = 0.37), 63-138-arcmin annuli of fixed retinal illuminance. The stimuli were imaged on the fovea in Maxwellian view as 500-ms flashes with 10-s interstimulus intervals. Observers decreased the intensity of the test center until it was first perceived as completely black. Action spectra determined for two surround levels [2.5 and 3.5 log trolands] had three sensitivity peaks (at approximately 440, 540, and 600 nm), However, when monochromatic surrounds were adjusted to induce blackness in a broadband center, action spectra were unimodal and identical to functions obtained by heterochromatic flicker photometry. Tests of additivity revealed that when blackness is induced by broadband surround into a bichromatic center, there is an additivity failure of the cancellation type. This additivity failure indicates that blackness induction is influenced, in part, by signals from opponent-chromatic pathways. A quantitative model is presented to account for these data. This model assumes that blackness induction is determined by the ratio of responses to the stimulus center and the annulus, and while signals form the annulus are based only on achromatic information, responses from the center are based on both chromatic and achromatic properties of the stimulus.

  11. Chromate Dissociation from Primer Paint in Simulated Lung Fluid.

    DTIC Science & Technology

    2000-03-01

    not done properly. Chromium is found naturally in the earth’s crust; trivalent chromium is a necessary dietary mineral. Other oxidative states such...exposures to chromium can include welding , leather tanning, electroplating, textile manufacturing, photoengraving, copier servicing and paints/pigments...production, production of chromates and chromate pigments, leather tanning, chromium plating and welding . Unfortunately, no detailed health studies have

  12. Abnormal pupillary light reflex with chromatic pupillometry in Gaucher disease

    PubMed Central

    Narita, Aya; Shirai, Kentarou; Kubota, Norika; Takayama, Rumiko; Takahashi, Yukitoshi; Onuki, Takanori; Numakura, Chikahiko; Kato, Mitsuhiro; Hamada, Yusuke; Sakai, Norio; Ohno, Atsuko; Asami, Maya; Matsushita, Shoko; Hayashi, Anri; Kumada, Tomohiro; Fujii, Tatsuya; Horino, Asako; Inoue, Takeshi; Kuki, Ichiro; Asakawa, Ken; Ishikawa, Hitoshi; Ohno, Koyo; Nishimura, Yoko; Tamasaki, Akiko; Maegaki, Yoshihiro; Ohno, Kousaku

    2014-01-01

    The hallmark of neuronopathic Gaucher disease (GD) is oculomotor abnormalities, but ophthalmological assessment is difficult in uncooperative patients. Chromatic pupillometry is a quantitative method to assess the pupillary light reflex (PLR) with minimal patient cooperation. Thus, we investigated whether chromatic pupillometry could be useful for neurological evaluations in GD. In our neuronopathic GD patients, red light-induced PLR was markedly impaired, whereas blue light-induced PLR was relatively spared. In addition, patients with non-neuronopathic GD showed no abnormalities. These novel findings show that chromatic pupillometry is a convenient method to detect neurological signs and monitor the course of disease in neuronopathic GD. PMID:25356393

  13. Abnormal pupillary light reflex with chromatic pupillometry in Gaucher disease.

    PubMed

    Narita, Aya; Shirai, Kentarou; Kubota, Norika; Takayama, Rumiko; Takahashi, Yukitoshi; Onuki, Takanori; Numakura, Chikahiko; Kato, Mitsuhiro; Hamada, Yusuke; Sakai, Norio; Ohno, Atsuko; Asami, Maya; Matsushita, Shoko; Hayashi, Anri; Kumada, Tomohiro; Fujii, Tatsuya; Horino, Asako; Inoue, Takeshi; Kuki, Ichiro; Asakawa, Ken; Ishikawa, Hitoshi; Ohno, Koyo; Nishimura, Yoko; Tamasaki, Akiko; Maegaki, Yoshihiro; Ohno, Kousaku

    2014-02-01

    The hallmark of neuronopathic Gaucher disease (GD) is oculomotor abnormalities, but ophthalmological assessment is difficult in uncooperative patients. Chromatic pupillometry is a quantitative method to assess the pupillary light reflex (PLR) with minimal patient cooperation. Thus, we investigated whether chromatic pupillometry could be useful for neurological evaluations in GD. In our neuronopathic GD patients, red light-induced PLR was markedly impaired, whereas blue light-induced PLR was relatively spared. In addition, patients with non-neuronopathic GD showed no abnormalities. These novel findings show that chromatic pupillometry is a convenient method to detect neurological signs and monitor the course of disease in neuronopathic GD.

  14. Derivation of Human Chromatic Discrimination Ability from an Information-Theoretical Notion of Distance in Color Space.

    PubMed

    da Fonseca, María; Samengo, Inés

    2016-12-01

    The accuracy with which humans detect chromatic differences varies throughout color space. For example, we are far more precise when discriminating two similar orange stimuli than two similar green stimuli. In order for two colors to be perceived as different, the neurons representing chromatic information must respond differently, and the difference must be larger than the trial-to-trial variability of the response to each separate color. Photoreceptors constitute the first stage in the processing of color information; many more stages are required before humans can consciously report whether two stimuli are perceived as chromatically distinguishable. Therefore, although photoreceptor absorption curves are expected to influence the accuracy of conscious discriminability, there is no reason to believe that they should suffice to explain it. Here we develop information-theoretical tools based on the Fisher metric that demonstrate that photoreceptor absorption properties explain about 87% of the variance of human color discrimination ability, as tested by previous behavioral experiments. In the context of this theory, the bottleneck in chromatic information processing is determined by photoreceptor absorption characteristics. Subsequent encoding stages modify only marginally the chromatic discriminability at the photoreceptor level.

  15. Full-field chromatic confocal surface profilometry employing digital micromirror device correspondence for minimizing lateral cross talks

    NASA Astrophysics Data System (ADS)

    Chen, Liang-Chia; Chang, Yi-Wei; Li, Hau-Wei

    2012-08-01

    Full-field chromatic confocal surface profilometry employing a digital micromirror device (DMD) for spatial correspondence is proposed to minimize lateral cross-talks between individual detection sensors. Although full-field chromatic confocal profilometry is capable of enhancing measurement efficiency by completely removing time-consuming vertical scanning operation, its vertical measurement resolution and accuracy are still severely affected by the potential sensor lateral cross-talk problem. To overcome this critical bottleneck, a DMD-based chromatic confocal method is developed by employing a specially-designed objective for chromatic light dispersion, and a DMD for lateral pixel correspondence and scanning, thereby reducing the lateral cross-talk influence. Using the chromatic objective, the incident light is dispersed according to a pre-designed detection range of several hundred micrometers, and a full-field reflected light is captured by a three-chip color camera for multi color detection. Using this method, the full width half maximum of the depth response curve can be significantly sharpened, thus improving the vertical measurement resolution and repeatability of the depth detection. From our preliminary experimental evaluation, it is verified that the ±3σ repeatability of the height measurement can be kept within 2% of the overall measurement range.

  16. Color and emotion: effects of hue, saturation, and brightness.

    PubMed

    Wilms, Lisa; Oberfeld, Daniel

    2017-06-13

    Previous studies on emotional effects of color often failed to control all the three perceptual dimensions of color: hue, saturation, and brightness. Here, we presented a three-dimensional space of chromatic colors by independently varying hue (blue, green, red), saturation (low, medium, high), and brightness (dark, medium, bright) in a factorial design. The 27 chromatic colors, plus 3 brightness-matched achromatic colors, were presented via an LED display. Participants (N = 62) viewed each color for 30 s and then rated their current emotional state (valence and arousal). Skin conductance and heart rate were measured continuously. The emotion ratings showed that saturated and bright colors were associated with higher arousal. The hue also had a significant effect on arousal, which increased from blue and green to red. The ratings of valence were the highest for saturated and bright colors, and also depended on the hue. Several interaction effects of the three color dimensions were observed for both arousal and valence. For instance, the valence ratings were higher for blue than for the remaining hues, but only for highly saturated colors. Saturated and bright colors caused significantly stronger skin conductance responses. Achromatic colors resulted in a short-term deceleration in the heart rate, while chromatic colors caused an acceleration. The results confirm that color stimuli have effects on the emotional state of the observer. These effects are not only determined by the hue of a color, as is often assumed, but by all the three color dimensions as well as their interactions.

  17. Chromatic interocular-switch rivalry

    PubMed Central

    Christiansen, Jens H.; D'Antona, Anthony D.; Shevell, Steven K.

    2017-01-01

    Interocular-switch rivalry (also known as stimulus rivalry) is a kind of binocular rivalry in which two rivalrous images are swapped between the eyes several times a second. The result is stable periods of one image and then the other, with stable intervals that span many eye swaps (Logothetis, Leopold, & Sheinberg, 1996). Previous work used this close kin of binocular rivalry with rivalrous forms. Experiments here test whether chromatic interocular-switch rivalry, in which the swapped stimuli differ in only chromaticity, results in slow alternation between two colors. Swapping equiluminant rivalrous chromaticities at 3.75 Hz resulted in slow perceptual color alternation, with one or the other color often continuously visible for two seconds or longer (during which there were 15+ eye swaps). A well-known theory for sustained percepts from interocular-switch rivalry with form is inhibitory competition between binocular neurons driven by monocular neurons with matched orientation tuning in each eye; such binocular neurons would produce a stable response when a given orientation is swapped between the eyes. A similar model can account for the percepts here from chromatic interocular-switch rivalry and is underpinned by the neurophysiological finding that color-preferring binocular neurons are driven by monocular neurons from each eye with well-matched chromatic selectivity (Peirce, Solomon, Forte, & Lennie, 2008). In contrast to chromatic interocular-switch rivalry, luminance interocular-switch rivalry with swapped stimuli that differ in only luminance did not result in slowly alternating percepts of different brightnesses. PMID:28510624

  18. Differences in Brain Hemodynamics in Response to Achromatic and Chromatic Cards of the Rorschach

    PubMed Central

    2016-01-01

    Abstract. In order to investigate the effects of color stimuli of the Rorschach inkblot method (RIM), the cerebral activity of 40 participants with no history of neurological or psychiatric illness was scanned while they engaged in the Rorschach task. A scanned image of the ten RIM inkblots was projected onto a screen in the MRI scanner. Cerebral activation in response to five achromatic color cards and five chromatic cards were compared. As a result, a significant increase in brain activity was observed in bilateral visual areas V2 and V3, parietooccipital junctions, pulvinars, right superior temporal gyrus, and left premotor cortex for achromatic color cards (p < .001). For the cards with chromatic color, significant increase in brain activity was observed in left visual area V4 and left orbitofrontal cortex (p < .001). Furthermore, a conjoint analysis revealed various regions were activated in responding to the RIM. The neuropsychological underpinnings of the response process, as described by Acklin and Wu-Holt (1996), were largely confirmed. PMID:28239255

  19. Chromatic stability of acrylic resins of artificial eyes submitted to accelerated aging and polishing.

    PubMed

    Goiato, Marcelo Coelho; Santos, Daniela Micheline dos; Souza, Josiene Firmino; Moreno, Amália; Pesqueira, Aldiéris Alves

    2010-12-01

    Esthetics and durability of materials used to fabricate artificial eyes has been an important issue since artificial eyes are essential to restore esthetics and function, protect the remaining tissues and help with patients' psychological therapy. However, these materials are submitted to degrading effects of environmental agents on the physical properties of the acrylic resin. This study assessed the color stability of acrylic resins used to fabricate sclera in three basic shades (N1, N2 and N3) when subjected to accelerated aging, mechanical and chemical polishing. Specimens of each resin were fabricated and submitted to mechanical and chemical polishing. Chromatic analysis was performed before and after accelerated aging through ultraviolet reflection spectrophotometry. All specimens revealed color alteration following polishing and accelerated aging. The resins presented statistically significant chromatic alteration (p<0.01) between the periods of 252 and 1008 h. Both polishing methods presented no significant difference between the values of color derivatives of resins.

  20. Differences in Brain Hemodynamics in Response to Achromatic and Chromatic Cards of the Rorschach: A fMRI Study.

    PubMed

    Ishibashi, Masahiro; Uchiumi, Chigusa; Jung, Minyoung; Aizawa, Naoki; Makita, Kiyoshi; Nakamura, Yugo; Saito, Daisuke N

    2016-01-01

    In order to investigate the effects of color stimuli of the Rorschach inkblot method (RIM), the cerebral activity of 40 participants with no history of neurological or psychiatric illness was scanned while they engaged in the Rorschach task. A scanned image of the ten RIM inkblots was projected onto a screen in the MRI scanner. Cerebral activation in response to five achromatic color cards and five chromatic cards were compared. As a result, a significant increase in brain activity was observed in bilateral visual areas V2 and V3, parietooccipital junctions, pulvinars, right superior temporal gyrus, and left premotor cortex for achromatic color cards ( p < .001). For the cards with chromatic color, significant increase in brain activity was observed in left visual area V4 and left orbitofrontal cortex ( p < .001). Furthermore, a conjoint analysis revealed various regions were activated in responding to the RIM. The neuropsychological underpinnings of the response process, as described by Acklin and Wu-Holt (1996), were largely confirmed.

  1. Digital halftoning methods for selectively partitioning error into achromatic and chromatic channels

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.

    1990-01-01

    A method is described for reducing the visibility of artifacts arising in the display of quantized color images on CRT displays. The method is based on the differential spatial sensitivity of the human visual system to chromatic and achromatic modulations. Because the visual system has the highest spatial and temporal acuity for the luminance component of an image, a technique which will reduce luminance artifacts at the expense of introducing high-frequency chromatic errors is sought. A method based on controlling the correlations between the quantization errors in the individual phosphor images is explored. The luminance component is greatest when the phosphor errors are positively correlated, and is minimized when the phosphor errors are negatively correlated. The greatest effect of the correlation is obtained when the intensity quantization step sizes of the individual phosphors have equal luminances. For the ordered dither algorithm, a version of the method can be implemented by simply inverting the matrix of thresholds for one of the color components.

  2. Beneficial role of hydrophytes in removing Cr(VI) from wastewater in association with chromate-reducing bacterial strains Ochrobactrum intermedium and Brevibacterium.

    PubMed

    Faisal, Muhammad; Hasnain, Shahida

    2005-01-01

    This study deals with the use of three chromium-resistant bacterial strains (Ochrobactrum intermedium CrT-1, Brevibacterium CrT-13, and CrM-1) in conjunction with Eichornia crassipes for the removal of toxic chromium from wastewater. Bacterial strains resulted in reduced uptake of chromate into inoculated plants as compared to noninoculated control plants. In the presence of different heavy metals, chromium uptake into the plants was 28.7 and 7.15% less at an initial K2CrO4 concentration of 100 and 500 microg ml(-1) in comparison to a metal free chromium solution. K2CrO4 uptake into the plant occurred at different pHs tested, but maximum uptake was observed at pH 5. Nevertheless, the bacterial strains caused some decrease in chromate uptake into the plants, but the combined effect of plants and bacterial strains conduce more removal of Cr(VI) from the solution.

  3. Modulation of the phenolic composition and colour of red wines subjected to accelerated ageing by controlling process variables.

    PubMed

    González-Sáiz, J M; Esteban-Díez, I; Rodríguez-Tecedor, S; Pérez-Del-Notario, N; Arenzana-Rámila, I; Pizarro, C

    2014-12-15

    The aim of the present work was to evaluate the effect of the main factors conditioning accelerated ageing processes (oxygen dose, chip dose, wood origin, toasting degree and maceration time) on the phenolic and chromatic profiles of red wines by using a multivariate strategy based on experimental design methodology. The results obtained revealed that the concentrations of monomeric anthocyanins and flavan-3-ols could be modified through the application of particular experimental conditions. This fact was particularly remarkable since changes in phenolic profile were closely linked to changes observed in chromatic parameters. The main strength of this study lies in the possibility of using its conclusions as a basis to make wines with specific colour properties based on quality criteria. To our knowledge, the influence of such a large number of alternative ageing parameters on wine phenolic composition and chromatic attributes has not been studied previously using a comprehensive experimental design methodology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Oxidation Control with Chromate Pretreatment of MCrAlY Unmelted Particle and Bond Coat in Thermal Barrier Systems

    NASA Astrophysics Data System (ADS)

    Yamano, Hideaki; Tani, Kazumi; Harada, Yoshio; Teratani, Takema

    2008-06-01

    MCrAlY alloy bond coat is widely used in thermal barrier coating (TBC) systems to protect substrates from high-temperature oxidizing environments. However, failure of the ceramic topcoat can occur due to a thermally grown oxide (TGO) that grows at the interface between the bond coat and the topcoat. In this study, the effect of chromate treatment was investigated. Prior to topcoat deposition, a thin film of Cr2O3 was formed on the bond coat surface. High-temperature oxidation tests were carried out, and the oxidation rates were determined by inspection of cross sections. Similar oxidation tests were carried out using MCrAlY powder material assumed to be unmelted particles. As a result, the chromate-treated bond coat showed outstanding oxidation resistance. Calculations that take into account the oxidation of particles in the topcoat indicated the generation of internal stress to cause local fracture of the topcoat.

  5. Extending the depth of field with chromatic aberration for dual-wavelength iris imaging.

    PubMed

    Fitzgerald, Niamh M; Dainty, Christopher; Goncharov, Alexander V

    2017-12-11

    We propose a method of extending the depth of field to twice that achievable by conventional lenses for the purpose of a low cost iris recognition front-facing camera in mobile phones. By introducing intrinsic primary chromatic aberration in the lens, the depth of field is doubled by means of dual wavelength illumination. The lens parameters (radius of curvature, optical power) can be found analytically by using paraxial raytracing. The effective range of distances covered increases with dispersion of the glass chosen and with larger distance for the near object point.

  6. Display Parameters and Requirements

    NASA Astrophysics Data System (ADS)

    Bahadur, Birendra

    The following sections are included: * INTRODUCTION * HUMAN FACTORS * Anthropometry * Sensory * Cognitive * Discussions * THE HUMAN VISUAL SYSTEM - CAPABILITIES AND LIMITATIONS * Cornea * Pupil and Iris * Lens * Vitreous Humor * Retina * RODS - NIGHT VISION * CONES - DAY VISION * RODS AND CONES - TWILIGHT VISION * VISUAL PIGMENTS * MACULA * BLOOD * CHOROID COAT * Visual Signal Processing * Pathways to the Brain * Spatial Vision * Temporal Vision * Colour Vision * Colour Blindness * DICHROMATISM * Protanopia * Deuteranopia * Tritanopia * ANOMALOUS TRICHROMATISM * Protanomaly * Deuteranomaly * Tritanomaly * CONE MONOCHROMATISM * ROD MONOCHROMATISM * Using Colour Effectively * COLOUR MIXTURES AND THE CHROMATICITY DIAGRAM * Colour Matching Functions and Chromaticity Co-ordinates * CIE 1931 Colour Space * CIE PRIMARIES * CIE COLOUR MATCHING FUNCTIONS AND CHROMATICITY CO-ORDINATES * METHODS FOR DETERMINING TRISTIMULUS VALUES AND COLOUR CO-ORDINATES * Spectral Power Distribution Method * Filter Method * CIE 1931 CHROMATICITY DIAGRAM * ADDITIVE COLOUR MIXTURE * CIE 1976 Chromaticity Diagram * CIE Uniform Colour Spaces and Colour Difference Formulae * CIELUV OR L*u*v* * CIELAB OR L*a*b* * CIE COLOUR DIFFERENCE FORMULAE * Colour Temperature and CIE Standard Illuminants and source * RADIOMETRIC AND PHOTOMETRIC QUANTITIES * Photopic (Vλ and Scotopic (Vλ') Luminous Efficiency Function * Photometric and Radiometric Flux * Luminous and Radiant Intensities * Incidence: Illuminance and Irradiance * Exitance or Emittance (M) * Luminance and Radiance * ERGONOMIC REQUIREMENTS OF DISPLAYS * ELECTRO-OPTICAL PARAMETERS AND REQUIREMENTS * Contrast and Contrast Ratio * Luminance and Brightness * Colour Contrast and Chromaticity * Glare * Other Aspects of Legibility * SHAPE AND SIZE OF CHARACTERS * DEFECTS AND BLEMISHES * FLICKER AND DISTORTION * ANGLE OF VIEW * Switching Speed * Threshold and Threshold Characteristic * Measurement Techniques For Electro-optical Parameters * RADIOMETRIC MEASUREMENTS * Broadband Radiometry or Filtered Photodetector Radiometric Method * Spectroradiometric Method * PHOTOMETRIC MEASUREMENTS * COLOUR MEASUREMENTS * LUMINANCE, CONTRAST RATIO, THRESHOLD CHARACTERISTIC AND POLAR PLOT * SWITCHING SPEED * ELECTRICAL AND LIFE PARAMETERS AND REQUIREMENTS * Operating Voltage, Current Drainage and Power Consumption * Operating Frequency * Life Expectancy * LCD FAILURE MODES * Liquid Crystal Materials * Substrate Glass * Electrode Patterns * Alignment and Aligning Material * Peripheral and End Plug Seal * Spacers * Crossover Material * Polarizers and Reflectors * Connectors * Heater * Colour Filters * Backlighting System * Explanation For Some of the Observed Defects * BLOOMING PIXELS * POLARIZER RELATED DEFECTS * DIFFERENTIAL THERMAL EXPANSION RELATED DEFECTS * ELECTROCHEMICAL AND ELECTROHYDRODYNAMIC RELATED DEFECTS * REVERSE TWIST AND REVERSE TILT * MEMORY OR REMINISCENT CONTRAST * LCD RELIABILRY AND ACCELERATED LIFE TESTING * ACKNOWLEDGEMENTS * REFERENCES * APPENDIX

  7. Things That Go Boom!: Noise and Toxic Exposures Associated with Weapon Systems

    DTIC Science & Technology

    2010-06-17

    Munitions Pyrotechnics Tracers Spot ing Charges Oxidizers Delay Elements Propellatl s Fuses De· onators Pr~n1ers Constituent of Concern BariL ...r11 chromate Potassium perchlorate lead oxide BariL m chromate P a tass ~L m perch I o r,ate l e ad chromate An1n1onil tll perch lara e P a

  8. Chromate dermatitis from a boiler lining.

    PubMed

    Rycroft, R J; Calnan, C D

    1977-08-01

    Chromate dermatitis is described in a mechanical fitter working inside boiler combustion chambers. A source of hexavalent chromate is traced to the action of the heat and alkaline fuel ash on trivalent chrome ore in parts of the refractory lining. Removal of the patient from this contact has resulted in almost complete clearing of his dermatitis, without any relapse, during a 9-month follow-up period.

  9. Evaluation of chromatic cues for trapping Bactrocera tau.

    PubMed

    Li, Lei; Ma, Huabo; Niu, Liming; Han, Dongyin; Zhang, Fangping; Chen, Junyu; Fu, Yueguan

    2017-01-01

    Trapping technology based on chromatic cues is an important strategy in controlling Tephritidae (fruit flies). The objectives of this present study were to evaluate the preference of Bactrocera tau for different chromatic cues, and to explore an easy method to print and reproduce coloured paper. Chromatic cues significantly affected the preference of adult B. tau. Wavelengths in the 515-604 nm range were the suitable wavelengths for trapping B. tau. Different-day-old B. tau had different colour preferences. Virtual wavelengths of 595 nm (yellow) and 568 nm (yellowish green) were the optimum wavelengths for trapping 5-7-day-old B. tau and 30-32-day-old B. tau respectively. The trap type and height significantly influenced B. tau attraction efficiency. The number of B. tau on coloured traps hung perpendicular to plant rows was not significantly higher than the number on traps hung parallel to plant rows. The quantisation of colour on the basis of Bruton's wavelength to RGB function can serve as an alternative method for printing and reproducing coloured paper, but a corrected equation should be established between the theoretical wavelength and actual wavelength of coloured paper. Results show that a compound paper coloured yellow (595 nm) and yellowish green (568 nm) installed at 60 and 90 cm above the ground shows the maximum effect for trapping B. tau. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  10. Measuring chromatic aberrations in imaging systems using plasmonic nanoparticles.

    PubMed

    Gennaro, Sylvain D; Roschuk, Tyler R; Maier, Stefan A; Oulton, Rupert F

    2016-04-01

    We demonstrate a method to measure chromatic aberrations of microscope objectives with metallic nanoparticles using white light. Extinction spectra are recorded while scanning a single nanoparticle through a lens's focal plane. We show a direct correlation between the focal wavelength and the longitudinal chromatic focal shift through our analysis of the variations between the scanned extinction spectra at each scan position and the peak extinction over the entire scan. The method has been tested on achromat and apochromat objectives using aluminum disks varying in size from 260-520 nm. Our method is straightforward, robust, low cost, and broadband with a sensitivity suitable for assessing longitudinal chromatic aberrations in high-numerical-aperture apochromatic corrected lenses.

  11. Dispersion induced power fading for radio frequency signals and its application for fast online PMD and CD monitoring

    NASA Astrophysics Data System (ADS)

    Ning, G.; Shum, P.

    2007-06-01

    We derive the expressions for the power fading including first-order polarization mode dispersion (PMD), chromatic dispersion, chirp parameter as well as polarization-dependent chromatic dispersion (PCD), which is dependent on the angle of precession of output state of polarization around the PMD vector. From the expression for radio frequency (RF) signals power fading, we get the average power fading for chromatic dispersion, chirp parameter, first-order PMD and PCD for both double sideband (DSB) modulation and single sideband (SSB) modulation. We also demonstrate a fast PMD and chromatic dispersion monitoring technology with reduced polarization-dependent gain. The measured results agree well with theoretical analysis.

  12. Chromate Dermatitis from Paint

    PubMed Central

    Engel, H. O.; Calnan, C. D.

    1963-01-01

    Among 250 workers engaged on wet sandpapering of primer paint on car bodies 65 developed a contact dermatitis. The average latent period before dermatitis developed was 4·6 months: only 60% of the patients made a completely satisfactory recovery. The average duration of dermatitis was 5·3 months. Two thirds of the men used one of two barrier creams supplied, while one third used none. Routine patch testing showed that the majority was allergic to chromate. It was found that a primer paint contained zinc chromate, which had been introduced into the paint by the manufacturers shortly before the first cases occurred. Removal of chromate from the paint resulted in a prompt cessation of new cases of dermatitis. Images PMID:14046155

  13. Effect of addition of commercial grape seed tannins on phenolic composition, chromatic characteristics, and antioxidant activity of red wine.

    PubMed

    Neves, Ana C; Spranger, Maria I; Zhao, Yuqing; Leandro, Maria C; Sun, Baoshan

    2010-11-24

    The effect of addition of grape seed tannins on the phenolic composition, chromatic characteristics, and antioxidant activity of red wine was studied. Two highly pure commercial grape seed tannins (GSE100 and GSE300) were selected, and their phenolic compositions were determined. Two types of red wines were made with Castelão/Tinta Miúda (3/2, w/w) grapevine varieties by fermentation on skin using two different maceration times, which correspond to the wines rich and poor in polyphenols, respectively. Each of these wines was used for experimentation with the addition of GSE100 and GSE300 before and immediately after alcoholic fermentation. Phenolic composition, chromatic characteristics, and antioxidant activity of the finished red wines were analyzed by HPLC-DAD, CIElab 76 convention, and DPPH radical test, respectively. The results showed that the addition of grape seed tannins had obvious effects of increasing color intensity and antioxidant activity only in the wines poor in polyphenols. Although GSE300 contained much higher amounts of di- and trimer procyanidins and a lower amount of polymeric proanthocyanidins, it provided effects of increasing the color intensity and antioxidant activity of the wines poor in polyphenols similar to those of GSE100. Furthermore, GSE100 released more gallic acid to wines than GSE300, although no gallic acid was detected in GSE100. Tannins added after alcoholic fermentation had a better effect on phenolic composition of red wine than tannins added before alcoholic fermentation.

  14. Self-referenced axial chromatic dispersion measurement in multiphoton microscopy through 2-color THG imaging.

    PubMed

    Du, Yu; Zhuang, Ziwei; He, Jiexing; Liu, Hongji; Qiu, Ping; Wang, Ke

    2018-05-16

    With tunable excitation light, multiphoton microscopy (MPM) is widely used for imaging biological structures at subcellular resolution. Axial chromatic dispersion, present in virtually every transmissive optical system including the multiphoton microscope, leads to focal (and the resultant image) plane separation. Here we demonstrate experimentally a technique to measure the axial chromatic dispersion in a multiphoton microscope, using simultaneous 2-color third-harmonic generation (THG) imaging excited by a 2-color soliton source with tunable wavelength separation. Our technique is self-referenced, eliminating potential measurement error when 1-color tunable excitation light is used which necessitates reciprocating motion of the mechanical translation stage. Using this technique, we demonstrate measured axial chromatic dispersion with 2 different objective lenses in a multiphoton microscope. Further measurement in a biological sample also indicates that this axial chromatic dispersion, in combination with 2-color imaging, may open up opportunity for simultaneous imaging of two different axial planes. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Chromatic confocal microscopy for multi-depth imaging of epithelial tissue

    PubMed Central

    Olsovsky, Cory; Shelton, Ryan; Carrasco-Zevallos, Oscar; Applegate, Brian E.; Maitland, Kristen C.

    2013-01-01

    We present a novel chromatic confocal microscope capable of volumetric reflectance imaging of microstructure in non-transparent tissue. Our design takes advantage of the chromatic aberration of aspheric lenses that are otherwise well corrected. Strong chromatic aberration, generated by multiple aspheres, longitudinally disperses supercontinuum light onto the sample. The backscattered light detected with a spectrometer is therefore wavelength encoded and each spectrum corresponds to a line image. This approach obviates the need for traditional axial mechanical scanning techniques that are difficult to implement for endoscopy and susceptible to motion artifact. A wavelength range of 590-775 nm yielded a >150 µm imaging depth with ~3 µm axial resolution. The system was further demonstrated by capturing volumetric images of buccal mucosa. We believe these represent the first microstructural images in non-transparent biological tissue using chromatic confocal microscopy that exhibit long imaging depth while maintaining acceptable resolution for resolving cell morphology. Miniaturization of this optical system could bring enhanced speed and accuracy to endomicroscopic in vivo volumetric imaging of epithelial tissue. PMID:23667789

  16. Achromatic-chromatic colorimetric sensors for on-off type detection of analytes.

    PubMed

    Heo, Jun Hyuk; Cho, Hui Hun; Lee, Jin Woong; Lee, Jung Heon

    2014-12-21

    We report the development of achromatic colorimetric sensors; sensors changing their colors from achromatic black to other chromatic colors. An achromatic colorimetric sensor was prepared by mixing a general colorimetric indicator, whose color changes between chromatic colors, and a complementary colored dye with no reaction to the targeted analyte. As the color of an achromatic colorimetric sensor changes from black to a chromatic color, the color change could be much easily recognized than general colorimetric sensors with naked eyes. More importantly, the achromatic colorimetric sensors enable on-off type recognition of the presence of analytes, which have not been achieved from most colorimetric sensors. In addition, the color changes from some achromatic colorimetric sensors (achromatic Eriochrome Black T and achromatic Benedict's solution) could be recognized with naked eyes at much lower concentration ranges than normal chromatic colorimetric sensors. These results provide new opportunities in the use of colorimetric sensors for diverse applications, such as harsh industrial, environmental, and biological detection.

  17. Quantitative measurement of binocular color fusion limit for non-spectral colors.

    PubMed

    Jung, Yong Ju; Sohn, Hosik; Lee, Seong-il; Ro, Yong Man; Park, Hyun Wook

    2011-04-11

    Human perception becomes difficult in the event of binocular color fusion when the color difference presented for the left and right eyes exceeds a certain threshold value, known as the binocular color fusion limit. This paper discusses the binocular color fusion limit for non-spectral colors within the color gamut of a conventional LCD 3DTV. We performed experiments to measure the color fusion limit for eight chromaticity points sampled from the CIE 1976 chromaticity diagram. A total of 2480 trials were recorded for a single observer. By analyzing the results, the color fusion limit was quantified by ellipses in the chromaticity diagram. The semi-minor axis of the ellipses ranges from 0.0415 to 0.0923 in terms of the Euclidean distance in the u'v´ chromaticity diagram and the semi-major axis ranges from 0.0640 to 0.1560. These eight ellipses are drawn on the chromaticity diagram. © 2011 Optical Society of America

  18. Cr6+-containing phases in the system CaO-Al2O3-CrO42--H2O at 23 °C

    NASA Astrophysics Data System (ADS)

    Pöllmann, Herbert; Auer, Stephan

    2012-01-01

    Synthesis and investigation of lamellar calcium aluminium hydroxy salts was performed to study the incorporation of chromate ions in the interlayer of lamellar calcium aluminium hydroxy salts. Different AFm-phases (calcium aluminate hydrate with alumina, ferric oxide, mono-anion phase) containing chromate were synthesized. These AFm-phases belong to the group of layered double hydroxides (LDHs). 3CaO·Al2O3·CaCrO4·nH2O and C3A·1/2Ca(OH)2·1/2CaCrO4·12H2O were obtained as pure phases and their different distinct interlayer water contents and properties determined. Solid solution of chromate-containing phases and tetracalcium-aluminate-hydrate (TCAH) were studied. The uptake of chromate into TCAH from solutions was proven. Chromate contents in solution decrease to <0.2 mg/l.

  19. Purchase of a Raman and Photoluminescence Imaging System for Characterization of Advanced Electrochemical and Electronic Materials

    DTIC Science & Technology

    2016-01-05

    2015, Abstract #1092. The Role of Chromium (III) in the Corrosion Inhibition of AA2024-T3 By Trivalent Chromium Process Coatings by Greg Swain...to replace chromate conversion coatings and primers with more environmentally-friendly, non-chromated coatings. The Trivalent Chromium Process (TCP...coatings and primers with more environmentally-friendly, non-chromated coatings. The Trivalent Chromium Process (TCP) coating, originally developed

  20. Simultaneous chromatic and luminance human electroretinogram responses.

    PubMed

    Parry, Neil R A; Murray, Ian J; Panorgias, Athanasios; McKeefry, Declan J; Lee, Barry B; Kremers, Jan

    2012-07-01

    The parallel processing of information forms an important organisational principle of the primate visual system. Here we describe experiments which use a novel chromatic–achromatic temporal compound stimulus to simultaneously identify colour and luminance specific signals in the human electroretinogram (ERG). Luminance and chromatic components are separated in the stimulus; the luminance modulation has twice the temporal frequency of the chromatic modulation. ERGs were recorded from four trichromatic and two dichromatic subjects (1 deuteranope and 1 protanope). At isoluminance, the fundamental (first harmonic) response was elicited by the chromatic component in the stimulus. The trichromatic ERGs possessed low-pass temporal tuning characteristics, reflecting the activity of parvocellular post-receptoral mechanisms. There was very little first harmonic response in the dichromats' ERGs. The second harmonic response was elicited by the luminance modulation in the compound stimulus and showed, in all subjects, band-pass temporal tuning characteristic of magnocellular activity. Thus it is possible to concurrently elicit ERG responses from the human retina which reflect processing in both chromatic and luminance pathways. As well as providing a clear demonstration of the parallel nature of chromatic and luminance processing in the human retina, the differences that exist between ERGs from trichromatic and dichromatic subjects point to the existence of interactions between afferent post-receptoral pathways that are in operation from the earliest stages of visual processing.

  1. Mixing of Chromatic and Luminance Retinal Signals in Primate Area V1

    PubMed Central

    Li, Xiaobing; Chen, Yao; Lashgari, Reza; Bereshpolova, Yulia; Swadlow, Harvey A.; Lee, Barry B.; Alonso, Jose Manuel

    2015-01-01

    Vision emerges from activation of chromatic and achromatic retinal channels whose interaction in visual cortex is still poorly understood. To investigate this interaction, we recorded neuronal activity from retinal ganglion cells and V1 cortical cells in macaques and measured their visual responses to grating stimuli that had either luminance contrast (luminance grating), chromatic contrast (chromatic grating), or a combination of the two (compound grating). As with parvocellular or koniocellular retinal ganglion cells, some V1 cells responded mostly to the chromatic contrast of the compound grating. As with magnocellular retinal ganglion cells, other V1 cells responded mostly to the luminance contrast and generated a frequency-doubled response to equiluminant chromatic gratings. Unlike magnocellular and parvocellular retinal ganglion cells, V1 cells formed a unimodal distribution for luminance/color preference with a 2- to 4-fold bias toward luminance. V1 cells associated with positive local field potentials in deep layers showed the strongest combined responses to color and luminance and, as a population, V1 cells encoded a diverse combination of luminance/color edges that matched edge distributions of natural scenes. Taken together, these results suggest that the primary visual cortex combines magnocellular and parvocellular retinal inputs to increase cortical receptive field diversity and to optimize visual processing of our natural environment. PMID:24464943

  2. Spectral discrimination in color blind animals via chromatic aberration and pupil shape.

    PubMed

    Stubbs, Alexander L; Stubbs, Christopher W

    2016-07-19

    We present a mechanism by which organisms with only a single photoreceptor, which have a monochromatic view of the world, can achieve color discrimination. An off-axis pupil and the principle of chromatic aberration (where different wavelengths come to focus at different distances behind a lens) can combine to provide "color-blind" animals with a way to distinguish colors. As a specific example, we constructed a computer model of the visual system of cephalopods (octopus, squid, and cuttlefish) that have a single unfiltered photoreceptor type. We compute a quantitative image quality budget for this visual system and show how chromatic blurring dominates the visual acuity in these animals in shallow water. We quantitatively show, through numerical simulations, how chromatic aberration can be exploited to obtain spectral information, especially through nonaxial pupils that are characteristic of coleoid cephalopods. We have also assessed the inherent ambiguity between range and color that is a consequence of the chromatic variation of best focus with wavelength. This proposed mechanism is consistent with the extensive suite of visual/behavioral and physiological data that has been obtained from cephalopod studies and offers a possible solution to the apparent paradox of vivid chromatic behaviors in color blind animals. Moreover, this proposed mechanism has potential applicability in organisms with limited photoreceptor complements, such as spiders and dolphins.

  3. Deficient Repair of Particulate Hexavalent chromium-Induced DNA Double Strand Breaks Leads To Neoplastic Transformation

    PubMed Central

    Xie, Hong; Wise, Sandra S.; Wise, John. P.

    2008-01-01

    Hexavalent chromium (Cr(VI)) is a potent respiratory toxicant and carcinogen. The most carcinogenic forms of Cr(VI) are the particulate salts such as lead chromate, which deposit and persist in the respiratory tract after inhalation. We demonstrate here that particulate chromate induces DNA double strand breaks in human lung cells with 0.1, 0.5, and 1 ug/cm2 lead chromate inducing 1.5, 2 and 5 relative increases in the percent of DNA in the comet tail, respectively. These lesions are repaired within 24 h and require Mre11 expression for their repair. Particulate chromate also caused Mre11 to co-localize with gamma-H2A.X and ATM. Failure to repair these breaks with Mre11 induced neoplastic transformation including loss of cell contact inhibition and anchorage independent growth. A 5-day exposure to lead chromate induced loss of cell contact inhibition in a concentration-dependent manner with 0, 0.1, 0.5 and 1 ug/cm2 lead chromate inducing 1, 78 and 103 foci in 20 dishes, respectively. These data indicate that Mre11 is critical to repairing particulate Cr(VI)-induced double strand breaks and preventing Cr(VI)-induced neoplastic transformation. PMID:18023605

  4. Primary chromatic aberration elimination via optimization work with genetic algorithm

    NASA Astrophysics Data System (ADS)

    Wu, Bo-Wen; Liu, Tung-Kuan; Fang, Yi-Chin; Chou, Jyh-Horng; Tsai, Hsien-Lin; Chang, En-Hao

    2008-09-01

    Chromatic Aberration plays a part in modern optical systems, especially in digitalized and smart optical systems. Much effort has been devoted to eliminating specific chromatic aberration in order to match the demand for advanced digitalized optical products. Basically, the elimination of axial chromatic and lateral color aberration of an optical lens and system depends on the selection of optical glass. According to reports from glass companies all over the world, the number of various newly developed optical glasses in the market exceeds three hundred. However, due to the complexity of a practical optical system, optical designers have so far had difficulty in finding the right solution to eliminate small axial and lateral chromatic aberration except by the Damped Least Squares (DLS) method, which is limited in so far as the DLS method has not yet managed to find a better optical system configuration. In the present research, genetic algorithms are used to replace traditional DLS so as to eliminate axial and lateral chromatic, by combining the theories of geometric optics in Tessar type lenses and a technique involving Binary/Real Encoding, Multiple Dynamic Crossover and Random Gene Mutation to find a much better configuration for optical glasses. By implementing the algorithms outlined in this paper, satisfactory results can be achieved in eliminating axial and lateral color aberration.

  5. Optical influence of the type of illuminant, substrates and thickness of ceramic materials.

    PubMed

    Volpato, Cláudia Angela Maziero; Monteiro, Sylvio; de Andrada, Mauro Caldeira; Fredel, Márcio Celso; Petter, Carlos Otávio

    2009-01-01

    The present study is an instrumental evaluation of the optical influence of the type of illuminant, substrate and different thickness on the color of dental ceramics. Thirty ceramic disks were prepared from IPS-Empress and IPS-Empress2 in three different thicknesses (1.5, 2.0 and 2.5mm). Disks made of composite resin; silver-palladium alloy and gold were used as substrates. The disks with a 1.5mm thickness were placed on a neutral gray photographic paper and measured with a spectrophotometer under three illuminants: daylight (D65), incandescent light (A) and fluorescent light (F6). All ceramic disks were combined with the substrate disks and a spectrophotometer was used to measure the coordinates of lightness (L*) and chromaticity (a* and b*). Two-way ANOVA (p<0.05) was used to analyze the combinations of ceramics, substrates and illuminants tested considering the coordinates of lightness (L*) and chromaticity (a* and b*), and also differences of color (DeltaE), lightness (DeltaL*), chromaticity values (Deltaa* and Deltab*). For the illuminants tested, the results present significant differences for coordinates of chromaticity a* and b*, suggesting a metamerism effect. In combination with the substrates, the results present statistical differences in all the tested conditions, especially where there is no ceramic substructure. The presence of discolored tooth remnants or metallic posts and cores can interfere with the desired aesthetic result, based on the selection of color aided by a single luminous source. Thus, the substrate color effect, thickness of the ceramic materials and type of illuminant are important factors to be considered during the clinical application of the ceramic systems.

  6. Influence of storage duration and processing on chromatic attributes and flavonoid content of moxa floss.

    PubMed

    Lim, Min Yee; Huang, Jian; Zhao, Bai-xiao; Zou, Hui-qin; Yan, Yong-hong

    2016-01-01

    Moxibustion is an important traditional Chinese medicine therapy using heat from ignited moxa floss for disease treatment. The purpose of the present study is to establish a reproducible method to assess the color of moxa floss, discriminate the samples based on chromatic coordinates and explore the relationship between chromatic coordinates and total flavonoid content (TFC). Moxa floss samples of different storage years and production ratios were obtained from a moxa production factory in Henan Province, China. Chromatic coordinates (L*, a* and b*) were analyzed with an ultraviolet-visible spectrophotometer and the chroma (C*) and hue angle (h°) values were calculated. TFC was determined by a colorimetric method. Data were analyzed with correlation, principal component analysis (PCA). Significant differences in the chromatic values and TFC were observed among samples of different storage years and production ratios. Samples of higher production ratio displayed higher chromatic characteristics and lower TFC. Samples of longer storage years contained higher TFC. Preliminary separation of moxa floss production ratio was obtained by means of color feature maps developed using L*-a* or L*-b* as coordinates. PCA allowed the separation of the samples from their storage years and production ratios based on their chromatic characteristics and TFC. The use of a colorimetric technique and CIELAB coordinates coupled with chemometrics can be practical and objective for discriminating moxa floss of different storage years and production ratios. The development of color feature maps could be used as a model for classifying the color grading of moxa floss.

  7. Mapping chromatic pathways in the Drosophila visual system.

    PubMed

    Lin, Tzu-Yang; Luo, Jiangnan; Shinomiya, Kazunori; Ting, Chun-Yuan; Lu, Zhiyuan; Meinertzhagen, Ian A; Lee, Chi-Hon

    2016-02-01

    In Drosophila, color vision and wavelength-selective behaviors are mediated by the compound eye's narrow-spectrum photoreceptors R7 and R8 and their downstream medulla projection (Tm) neurons Tm5a, Tm5b, Tm5c, and Tm20 in the second optic neuropil or medulla. These chromatic Tm neurons project axons to a deeper optic neuropil, the lobula, which in insects has been implicated in processing and relaying color information to the central brain. The synaptic targets of the chromatic Tm neurons in the lobula are not known, however. Using a modified GFP reconstitution across synaptic partners (GRASP) method to probe connections between the chromatic Tm neurons and 28 known and novel types of lobula neurons, we identify anatomically the visual projection neurons LT11 and LC14 and the lobula intrinsic neurons Li3 and Li4 as synaptic targets of the chromatic Tm neurons. Single-cell GRASP analyses reveal that Li4 receives synaptic contacts from over 90% of all four types of chromatic Tm neurons, whereas LT11 is postsynaptic to the chromatic Tm neurons, with only modest selectivity and at a lower frequency and density. To visualize synaptic contacts at the ultrastructural level, we develop and apply a "two-tag" double-labeling method to label LT11's dendrites and the mitochondria in Tm5c's presynaptic terminals. Serial electron microscopic reconstruction confirms that LT11 receives direct contacts from Tm5c. This method would be generally applicable to map the connections of large complex neurons in Drosophila and other animals. © 2015 Wiley Periodicals, Inc.

  8. A Normative Data Set for the Clinical Assessment of Achromatic and Chromatic Contrast Sensitivity Using a qCSF Approach.

    PubMed

    Kim, Yeon Jin; Reynaud, Alexandre; Hess, Robert F; Mullen, Kathy T

    2017-07-01

    The measurement of achromatic sensitivity has been an important tool for monitoring subtle changes in vision as the result of disease or response to therapy. In this study, we aimed to provide a normative data set for achromatic and chromatic contrast sensitivity functions within a common cone contrast space using an abbreviated measurement approach suitable for clinical practice. In addition, we aimed to provide comparisons of achromatic and chromatic binocular summation across spatial frequency. We estimated monocular cone contrast sensitivity functions (CCSFs) using a quick Contrast Sensitivity Function (qCSF) approach for achromatic as well as isoluminant, L/M cone opponent, and S cone opponent stimuli in a healthy population of 51 subjects. We determined the binocular CCSFs for achromatic and chromatic vision to evaluate the degree of binocular summation across spatial frequency for these three different mechanisms in a subset of 20 subjects. Each data set shows consistent contrast sensitivity across the population. They highlight the extremely high cone contrast sensitivity of L/M cone opponency compared with the S-cone and achromatic responses. We also find that the two chromatic sensitivities are correlated across the healthy population. In addition, binocular summation for all mechanisms depends strongly on stimulus spatial frequency. This study, using an approach well suited to the clinic, is the first to provide a comparative normative data set for the chromatic and achromatic contrast sensitivity functions, yielding quantitative comparisons of achromatic, L/M cone opponent, and S cone opponent chromatic sensitivities as a function of spatial frequency.

  9. A possible role for chromium(III) in genotoxicity.

    PubMed

    Snow, E T

    1991-05-01

    Chromium is found in the environment in two major forms: reduced CrIII and CrVI, or chromate. Chromate, the most biologically active species, is readily taken up by living cells and reduced intracellularly, via reactive intermediates, to stable CrIII species. CrIII, the most abundant form of chromium in the environment, does not readily cross cell membranes and is relatively inactive in vivo. However, intracellular CrIII can react slowly with both nucleic acids and proteins and can be genotoxic. We have investigated the genotoxicity of CrIII in vitro using a DNA replication assay and in vivo by CaCl2-mediated transfection of chromium-treated DNA into Escherichia coli. When DNA replication was measured on a CrIII-treated template using purified DNA polymerases (either bacterial or mammalian), both the rate of DNA replication and the amount of incorporation per polymerase binding event (processivity) were greatly increased relative to controls. When transfected into E. coli, CrIII-treated M13mp2 bacteriophage DNA showed a dose-dependent increase in mutation frequency. These results suggest that CrIII alters the interaction between the DNA template and the polymerase such that the binding strength of the DNA polymerase is increased and the fidelity of DNA replication is decreased. These interactions may contribute to the mutagenicity of chromium ions in vivo and suggest that CrIII can contribute to chromium-mediated carcinogenesis.

  10. The Influence of Prefermentative Addition of Gallic Acid on the Phenolic Composition and Chromatic Characteristics of Cabernet Sauvignon Wines.

    PubMed

    Liu, Yue; Zhang, Bo; He, Fei; Duan, Chang-Qing; Shi, Ying

    2016-07-01

    In this study, the prefermentative addition of gallic acid in Cabernet Sauvignon red winemaking was performed. The influence of gallic acid addition on wine phenolic composition, the ratio of copigmentation, and the color parameters were monitored throughout the winemaking process. The results showed that the prefermentative addition of gallic acid enhanced the extraction of total anthocyanins and the copigmentation effect, producing wines with more darkness, redness, yellowness, and saturation. Moreover, the addition of gallic acid contributed to the concentration of total phenolic acids. However, it had a negative effect on the concentrations of flavonols and flavan-3-ols in the final wines. Thus, the prefermentative addition of gallic acid at appropriate levels might be a promising enological technology to obtain wines with high color quality and aging potential. © 2016 Institute of Food Technologists®

  11. Accelerated Corrosion Results for Zinc/Nickel-Plated Automotive Parts Posttreated With Trivalent Chromate Rinse

    DTIC Science & Technology

    2010-09-01

    400 and 300 h in neutral salt spray. 5 Similarly plated samples post treated with trivalent chromium rinse lasted 450 and 200 h in neutral salt...Accelerated Corrosion Results for Zinc/Nickel-Plated Automotive Parts Posttreated With Trivalent Chromate Rinse by Chris E. Miller, Brian E...Posttreated With Trivalent Chromate Rinse Chris E. Miller and Brian E. Placzankis Weapons and Materials Research Directorate, ARL I. Carl Handsy

  12. Corrosion Finishing/Coating Systems for DoD Metallic Substrates Based on Non-Chromate Inhibitors and UV Curable, Zero VOC Materials

    DTIC Science & Technology

    2010-08-01

    Corrosion resistant coatings containing non-chromate inhibitors and no volatile organic compounds were developed and evaluated for DoD applications...Transmission Electron Microscopy TRI – Toxic Release Inventory UV – Ultraviolet UVAs – Ultraviolet Absorbers VOCs – Volatile Organic Compounds XPS – X...containing non-chromate inhibitors and no volatile organic compounds were developed and evaluated for DoD applications. The technical effort

  13. Chromatic aberration compensation in numerical reconstruction of digital holograms by Fresnel-Bluestein propagation.

    PubMed

    Hincapie, Diego; Velasquez, Daniel; Garcia-Sucerquia, Jorge

    2017-12-15

    In this Letter, we present a method for chromatic compensation in numerical reconstruction of digitally recorded holograms based on Fresnel-Bluestein propagation. The proposed technique is applied to correct the chromatic aberration that arises in the reconstruction of RGB holograms of both millimeter- and micrometer-sized objects. The results show the feasibility of this strategy to remove the wavelength dependence of the size of the numerically propagated wavefields.

  14. Effect of degrading yellow oxo-biodegradable low-density polyethylene films to water quality

    NASA Astrophysics Data System (ADS)

    Requejo, B. A.; Pajarito, B. B.

    2017-05-01

    Polyethylene (PE) contributes largely to plastic wastes that are disposed in aquatic environment as a consequence of its widespread use. In this study, yellow oxo-biodegradable low-density PE films were immersed in deionized water at 50°C for 49 days. Indicators of water quality: pH, oxidation-reduction potential, turbidity, and total dissolved solids (TDS), were monitored at regular intervals. It was observed that pH initially rises and then slowly decreases with time, oxidation-reduction potential decreases then slowly increases with time, turbidity rises above the control at varied rates, and TDS increases abruptly and rises at a hindered rate. Moreover, the films potentially leach out lead chromate. The results imply that degrading oxo-biodegradable LDPE films results to significant reduction of water quality.

  15. Designing display primaries with currently available light sources for UHDTV wide-gamut system colorimetry.

    PubMed

    Masaoka, Kenichiro; Nishida, Yukihiro; Sugawara, Masayuki

    2014-08-11

    The wide-gamut system colorimetry has been standardized for ultra-high definition television (UHDTV). The chromaticities of the primaries are designed to lie on the spectral locus to cover major standard system colorimetries and real object colors. Although monochromatic light sources are required for a display to perfectly fulfill the system colorimetry, highly saturated emission colors using recent quantum dot technology may effectively achieve the wide gamut. This paper presents simulation results on the chromaticities of highly saturated non-monochromatic light sources and gamut coverage of real object colors to be considered in designing wide-gamut displays with color filters for the UHDTV.

  16. Chromatic multifocal pupillometer for objective early diagnosis of mild cognitive impairment

    NASA Astrophysics Data System (ADS)

    Rotenstreich, Ygal; Ben-Ner, Daniel; Sharvit-Ginon, Inbal; Ravona-Springer, Ramit; Beeri, Michal; Sher, Ifat

    2017-02-01

    The pupil responses of 15 cognitively normal subjects (ages 60-74) were examined in response to 76 focal red and blue light stimuli using a chromatic multifocal pupillometer (CMP). Subjects with low cognitive scores as determined as by Montreal Cognitive Assessment testing, presented significantly weaker and sluggish pupil responses in peripheral and central locations of the visual field in response to red and blue light. Our findings suggests that the CMP may present a novel objective, non-invasive, low cost technique for early diagnosis of cognitive decline that may serve for Alzheimer Disease prevention and as sensitive outcome measure of therapeutic effects.

  17. Chromatic signals control proboscis movements during hovering flight in the hummingbird hawkmoth Macroglossum stellatarum.

    PubMed

    Goyret, Joaquín; Kelber, Almut

    2012-01-01

    Most visual systems are more sensitive to luminance than to colour signals. Animals resolve finer spatial detail and temporal changes through achromatic signals than through chromatic ones. Probably, this explains that detection of small, distant, or moving objects is typically mediated through achromatic signals. Macroglossum stellatarum are fast flying nectarivorous hawkmoths that inspect flowers with their long proboscis while hovering. They can visually control this behaviour using floral markings known as nectar guides. Here, we investigate whether this is mediated by chromatic or achromatic cues. We evaluated proboscis placement, foraging efficiency, and inspection learning of naïve moths foraging on flower models with coloured markings that offered either chromatic, achromatic or both contrasts. Hummingbird hawkmoths could use either achromatic or chromatic signals to inspect models while hovering. We identified three, apparently independent, components controlling proboscis placement: After initial contact, 1) moths directed their probing towards the yellow colour irrespectively of luminance signals, suggesting a dominant role of chromatic signals; and 2) moths tended to probe mainly on the brighter areas of models that offered only achromatic signals. 3) During the establishment of the first contact, naïve moths showed a tendency to direct their proboscis towards the small floral marks independent of their colour or luminance. Moths learned to find nectar faster, but their foraging efficiency depended on the flower model they foraged on. Our results imply that M. stellatarum can perceive small patterns through colour vision. We discuss how the different informational contents of chromatic and luminance signals can be significant for the control of flower inspection, and visually guided behaviours in general.

  18. Stereo chromatic contrast sensitivity model to blue-yellow gratings.

    PubMed

    Yang, Jiachen; Lin, Yancong; Liu, Yun

    2016-03-07

    As a fundamental metric of human visual system (HVS), contrast sensitivity function (CSF) is typically measured by sinusoidal gratings at the detection of thresholds for psychophysically defined cardinal channels: luminance, red-green, and blue-yellow. Chromatic CSF, which is a quick and valid index to measure human visual performance and various retinal diseases in two-dimensional (2D) space, can not be directly applied into the measurement of human stereo visual performance. And no existing perception model considers the influence of chromatic CSF of inclined planes on depth perception in three-dimensional (3D) space. The main aim of this research is to extend traditional chromatic contrast sensitivity characteristics to 3D space and build a model applicable in 3D space, for example, strengthening stereo quality of 3D images. This research also attempts to build a vision model or method to check human visual characteristics of stereo blindness. In this paper, CRT screen was clockwise and anti-clockwise rotated respectively to form the inclined planes. Four inclined planes were selected to investigate human chromatic vision in 3D space and contrast threshold of each inclined plane was measured with 18 observers. Stimuli were isoluminant blue-yellow sinusoidal gratings. Horizontal spatial frequencies ranged from 0.05 to 5 c/d. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. According to the relationship between spatial frequency of inclined plane and horizontal spatial frequency, the chromatic contrast sensitivity characteristics in 3D space have been modeled based on the experimental data. The results show that the proposed model can well predicted human chromatic contrast sensitivity characteristics in 3D space.

  19. Evaluation of layered zinc hydroxide nitrate and zinc/nickel double hydroxide salts in the removal of chromate ions from solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bortolaz de Oliveira, Henrique; Wypych, Fernando, E-mail: wypych@ufpr.br

    Layered zinc hydroxide nitrate (ZnHN) and Zn/Ni layered double hydroxide salts were synthesized and used to remove chromate ions from solutions at pH 8.0. The materials were characterized by many instrumental techniques before and after chromate ion removal. ZnHN decomposed after contact with the chromate solution, whereas the layered structure of Zn/Ni hydroxide nitrate (Zn/NiHN) and Zn/Ni hydroxide acetate (Zn/NiHA) remained their layers intact after the topotactic anionic exchange reaction, only changing the basal distances. ZnHN, Zn/NiHN, and Zn/NiHA removed 210.1, 144.8, and 170.1 mg of CrO{sub 4}{sup 2−}/g of material, respectively. Although the removal values obtained for Zn/NiHN andmore » Zn/NiHA were smaller than the values predicted for the ideal formulas of the solids (194.3 and 192.4 mg of CrO{sub 4}{sup 2−}/g of material, respectively), the measured capacities were higher than the values achieved with many materials reported in the literature. Kinetic experiments showed the removal reaction was fast. To facilitate the solid/liquid separation process after chromium removal, Zn/Ni layered double hydroxide salts with magnetic supports were also synthesized, and their ability to remove chromate was evaluated. - Highlights: • Zinc hydroxide nitrate and Zn/Ni hydroxide nitrate or acetate were synthesized. • The interlayer anions were replaced by chromate anions at pH=8.0. • Only Zn/Ni hydroxide nitrate or acetate have the structure preserved after exchange. • Fast exchange reaction and high capacity of chromate removal were observed. • Magnetic materials were obtained to facilitate the solids removal the from solutions.« less

  20. Hexavalent chromium exposures during full-aircraft corrosion control.

    PubMed

    Carlton, Gary N

    2003-01-01

    Aluminum alloys used in the construction of modern aircraft are subject to corrosion. The principal means of controlling this corrosion in the U.S. Air Force are organic coatings. The organic coating system consists of a chromate conversion coat, epoxy resin primer, and polyurethane enamel topcoat. Hexavalent chromium (CrVI) is present in the conversion coat in the form of chromic acid and in the primer in the form of strontium chromate. CrVI inhalation exposures can occur when workers spray conversion coat onto bare metal and apply primer to the treated metal surface. In addition, mechanical abrasion of aircraft surfaces can generate particulates that contain chromates from previously applied primers and conversion coats. This study measured CrVI exposures during these corrosion control procedures. Mean time-weighted average (TWA) exposure to chromic acid during conversion coat treatment was 0.48 microg/m(3), below the current American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV(R)) TWA of 50 microg/m(3) for water-soluble CrVI compounds. Mean TWA exposures to strontium chromate were 5.33 microg/m(3) during mechanical abrasion and 83.8 microg/m(3) during primer application. These levels are in excess of the current ACGIH TLV-TWA of 0.5 microg/m(3) for strontium chromate. In the absence of a change from chromated to nonchromated conversion coats and primers, additional control measures are needed to reduce these exposures.

  1. Mixing of Chromatic and Luminance Retinal Signals in Primate Area V1.

    PubMed

    Li, Xiaobing; Chen, Yao; Lashgari, Reza; Bereshpolova, Yulia; Swadlow, Harvey A; Lee, Barry B; Alonso, Jose Manuel

    2015-07-01

    Vision emerges from activation of chromatic and achromatic retinal channels whose interaction in visual cortex is still poorly understood. To investigate this interaction, we recorded neuronal activity from retinal ganglion cells and V1 cortical cells in macaques and measured their visual responses to grating stimuli that had either luminance contrast (luminance grating), chromatic contrast (chromatic grating), or a combination of the two (compound grating). As with parvocellular or koniocellular retinal ganglion cells, some V1 cells responded mostly to the chromatic contrast of the compound grating. As with magnocellular retinal ganglion cells, other V1 cells responded mostly to the luminance contrast and generated a frequency-doubled response to equiluminant chromatic gratings. Unlike magnocellular and parvocellular retinal ganglion cells, V1 cells formed a unimodal distribution for luminance/color preference with a 2- to 4-fold bias toward luminance. V1 cells associated with positive local field potentials in deep layers showed the strongest combined responses to color and luminance and, as a population, V1 cells encoded a diverse combination of luminance/color edges that matched edge distributions of natural scenes. Taken together, these results suggest that the primary visual cortex combines magnocellular and parvocellular retinal inputs to increase cortical receptive field diversity and to optimize visual processing of our natural environment. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Simultaneous chromatic and luminance human electroretinogram responses

    PubMed Central

    Parry, Neil R A; Murray, Ian J; Panorgias, Athanasios; McKeefry, Declan J; Lee, Barry B; Kremers, Jan

    2012-01-01

    The parallel processing of information forms an important organisational principle of the primate visual system. Here we describe experiments which use a novel chromatic–achromatic temporal compound stimulus to simultaneously identify colour and luminance specific signals in the human electroretinogram (ERG). Luminance and chromatic components are separated in the stimulus; the luminance modulation has twice the temporal frequency of the chromatic modulation. ERGs were recorded from four trichromatic and two dichromatic subjects (1 deuteranope and 1 protanope). At isoluminance, the fundamental (first harmonic) response was elicited by the chromatic component in the stimulus. The trichromatic ERGs possessed low-pass temporal tuning characteristics, reflecting the activity of parvocellular post-receptoral mechanisms. There was very little first harmonic response in the dichromats’ ERGs. The second harmonic response was elicited by the luminance modulation in the compound stimulus and showed, in all subjects, band-pass temporal tuning characteristic of magnocellular activity. Thus it is possible to concurrently elicit ERG responses from the human retina which reflect processing in both chromatic and luminance pathways. As well as providing a clear demonstration of the parallel nature of chromatic and luminance processing in the human retina, the differences that exist between ERGs from trichromatic and dichromatic subjects point to the existence of interactions between afferent post-receptoral pathways that are in operation from the earliest stages of visual processing. PMID:22586211

  3. Spectral discrimination in color blind animals via chromatic aberration and pupil shape

    PubMed Central

    Stubbs, Alexander L.; Stubbs, Christopher W.

    2016-01-01

    We present a mechanism by which organisms with only a single photoreceptor, which have a monochromatic view of the world, can achieve color discrimination. An off-axis pupil and the principle of chromatic aberration (where different wavelengths come to focus at different distances behind a lens) can combine to provide “color-blind” animals with a way to distinguish colors. As a specific example, we constructed a computer model of the visual system of cephalopods (octopus, squid, and cuttlefish) that have a single unfiltered photoreceptor type. We compute a quantitative image quality budget for this visual system and show how chromatic blurring dominates the visual acuity in these animals in shallow water. We quantitatively show, through numerical simulations, how chromatic aberration can be exploited to obtain spectral information, especially through nonaxial pupils that are characteristic of coleoid cephalopods. We have also assessed the inherent ambiguity between range and color that is a consequence of the chromatic variation of best focus with wavelength. This proposed mechanism is consistent with the extensive suite of visual/behavioral and physiological data that has been obtained from cephalopod studies and offers a possible solution to the apparent paradox of vivid chromatic behaviors in color blind animals. Moreover, this proposed mechanism has potential applicability in organisms with limited photoreceptor complements, such as spiders and dolphins. PMID:27382180

  4. Spectrally resolved chromatic confocal interferometry for one-shot nano-scale surface profilometry with several tens of micrometric depth range

    NASA Astrophysics Data System (ADS)

    Chen, Liang-Chia; Chen, Yi-Shiuan; Chang, Yi-Wei; Lin, Shyh-Tsong; Yeh, Sheng Lih

    2013-01-01

    In this research, new nano-scale measurement methodology based on spectrally-resolved chromatic confocal interferometry (SRCCI) was successfully developed by employing integration of chromatic confocal sectioning and spectrally-resolve white light interferometry (SRWLI) for microscopic three dimensional surface profilometry. The proposed chromatic confocal method (CCM) using a broad band while light in combination with a specially designed chromatic dispersion objective is capable of simultaneously acquiring multiple images at a large range of object depths to perform surface 3-D reconstruction by single image shot without vertical scanning and correspondingly achieving a high measurement depth range up to hundreds of micrometers. A Linnik-type interferometric configuration based on spectrally resolved white light interferometry is developed and integrated with the CCM to simultaneously achieve nanoscale axis resolution for the detection point. The white-light interferograms acquired at the exit plane of the spectrometer possess a continuous variation of wavelength along the chromaticity axis, in which the light intensity reaches to its peak when the optical path difference equals to zero between two optical arms. To examine the measurement accuracy of the developed system, a pre-calibrated accurate step height target with a total step height of 10.10 μm was measured. The experimental result shows that the maximum measurement error was verified to be less than 0.3% of the overall measuring height.

  5. Chromatic confocal microscope using hybrid aspheric diffractive lenses

    NASA Astrophysics Data System (ADS)

    Rayer, Mathieu; Mansfield, Daniel

    2014-05-01

    A chromatic confocal microscope is a single point non-contact distance measurement sensor. For three decades the vast majority of the chromatic confocal microscope use refractive-based lenses to code the measurement axis chromatically. However, such an approach is limiting the range of applications. In this paper the performance of refractive, diffractive and Hybrid aspheric diffractive are compared. Hybrid aspheric diffractive lenses combine the low geometric aberration of a diffractive lens with the high optical power of an aspheric lens. Hybrid aspheric diffractive lenses can reduce the number of elements in an imaging system significantly or create large hyper- chromatic lenses for sensing applications. In addition, diffractive lenses can improve the resolution and the dynamic range of a chromatic confocal microscope. However, to be suitable for commercial applications, the diffractive optical power must be significant. Therefore, manufacturing such lenses is a challenge. We show in this paper how a theoretical manufacturing model can demonstrate that the hybrid aspheric diffractive configuration with the best performances is achieved by step diffractive surface. The high optical quality of step diffractive surface is then demonstrated experimentally. Publisher's Note: This paper, originally published on 5/10/14, was replaced with a corrected/revised version on 5/19/14. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.

  6. Investigation of the potential carcinogenicity of a range of chromium containing materials on rat lung.

    PubMed Central

    Levy, L S; Martin, P A; Bidstrup, P L

    1986-01-01

    Twenty one chromium containing materials were examined for carcinogenic activity in a two year study using an intrabronchial pellet implantation system whereby pellets loaded with test material were surgically implanted into the lower left bronchus of rats. The principal aim of the study was to extend our knowledge of the carcinogenic potential of chromium compounds and, in particular, chromates (Cr6+). A statistically significant incidence of treatment related lung tumours was found with some sparingly soluble chromate materials. All tumours were large keratinizing squamous carcinomas of the left lung, except for a single left lung adenocarcinoma and two left lung anaplastic carcinomas. No bronchial carcinomas (0/100) were seen in the negative control group (blank pellet loaded with cholesterol), whereas bronchial carcinomas (22/48 and 25/100) occurred in the two positive control groups which received pellets loaded with 20-methylcholanthrene and calcium chromate respectively. Among the 20 test materials, only three groups gave statistically significant numbers of bronchial carcinomas. Two of these were groups receiving different samples of strontium chromate which gave 43/99 and 62/99 tumours. The third group, zinc chromate (low solubility), gave 5/100 bronchial carcinomas. A further zinc chromate group (Norge composition) produced 3/100 bronchial carcinomas which was not statistically significant. A few lung tumours were observed in other test groups. Images PMID:3964573

  7. Pigment tests evaluated by a model of chromatic discrimination.

    PubMed

    Smith, V C; Pokorny, J; Yeh, T

    1993-08-01

    Clinical color-vision tests are evaluated within the framework of a model of chromatic discrimination in terms of cone excitation. The motivation for this study was to derive a method for evaluation of test design, test sensitivity, and observer performance. The discrimination model is based on the assumption that chromatic discrimination is mediated in two independent channels, one for short-wavelength cones and one for long- and middle-wavelength cones. Luminance-dependent templates are derived for each channel, and they describe chromatic-discrimination behavior of the young color-normal observer. The templates incorporate receptor- and opponent-level gain controls. We show how the chromaticities of clinical tests can be calculated in cone-excitation units and how discrimination behavior on the tests can be plotted on the templates. The tests include the Farnsworth-Munsell 100-hue, the Farnsworth Panel D-15, the Farnsworth Panel D-15 desaturated, the American Optical Hardy-Rand-Rittler, the Farnsworth F2 plate, the Standard Pseudoisochromatic Plates, Part II, the Ishihara, and the Minimalist tests. Clinical-test data collected on young color-normal observers at different illumination levels show the validity of the techniques.

  8. Chromatic and Achromatic Spatial Resolution of Local Field Potentials in Awake Cortex

    PubMed Central

    Jansen, Michael; Li, Xiaobing; Lashgari, Reza; Kremkow, Jens; Bereshpolova, Yulia; Swadlow, Harvey A.; Zaidi, Qasim; Alonso, Jose-Manuel

    2015-01-01

    Local field potentials (LFPs) have become an important measure of neuronal population activity in the brain and could provide robust signals to guide the implant of visual cortical prosthesis in the future. However, it remains unclear whether LFPs can detect weak cortical responses (e.g., cortical responses to equiluminant color) and whether they have enough visual spatial resolution to distinguish different chromatic and achromatic stimulus patterns. By recording from awake behaving macaques in primary visual cortex, here we demonstrate that LFPs respond robustly to pure chromatic stimuli and exhibit ∼2.5 times lower spatial resolution for chromatic than achromatic stimulus patterns, a value that resembles the ratio of achromatic/chromatic resolution measured with psychophysical experiments in humans. We also show that, although the spatial resolution of LFP decays with visual eccentricity as is also the case for single neurons, LFPs have higher spatial resolution and show weaker response suppression to low spatial frequencies than spiking multiunit activity. These results indicate that LFP recordings are an excellent approach to measure spatial resolution from local populations of neurons in visual cortex including those responsive to color. PMID:25416722

  9. Reversible Chromatic Response of Polydiacetylene Derivative Vesicles in D2O Solvent.

    PubMed

    Shin, Min Jae; Kim, Jong-Duk

    2016-01-26

    The thermal chromatic sensitivity of polydiacetylenes (PDAs) with 10,12-pentacosadiynoic acid (PCDA) derivatives, which have a hydroxyl group (HEEPCDA) and an amine group (APPCDA), were investigated using D2O and H2O as solvents. The vesicle solution with polymerized HEEPCDA exhibited a reversible chromatic response during the heating and cooling cycle in D2O, but not in H2O. On the other hand, the vesicle solution with the polymerized APPCDA exhibited a reversible chromatic response in H2O during the heating and cooling cycle, but the color of the solution did not change much in D2O. The critical vesicle concentration of HEEPCDA was lower in D2O than in H2O, and the chromatic sensitivity of the polymerized vesicles to temperature was slower in D2O than in H2O. We think that it is due to D2O being a more highly structured solvent than H2O with the hydrogen bonding in D2O stronger than that in H2O.

  10. Chromatic Dimensions Earthy, Watery, Airy, and Fiery.

    PubMed

    Albertazzi, Liliana; Koenderink, Jan J; van Doorn, Andrea

    2015-01-01

    In our study, for a small number of antonyms, we investigate whether they are cross-modally or ideaesthetically related to the space of colors. We analyze the affinities of seven antonyms (cold-hot, dull-radiant, dead-vivid, soft-hard, transparent-chalky, dry-wet, and acid-treacly) and their intermediate connotations (cool-warm, matt-shiny, numb-lively, mellow-firm, semi-transparent-opaque, semi-dry-moist, and sour-sweet) as a function of color. We find that some antonyms relate to chromatic dimensions, others to achromatic ones. The cold-hot antonym proves to be the most salient dimension. The dry-wet dimension coincides with the cold-hot dimension, with dry corresponding to hot and wet to cold. The acid-treacly dimension proves to be transversal to the cold-hot dimension; hence, the pairs mutually span the chromatic domain. The cold-hot and acid-treacly antonyms perhaps recall Hering's opponent color system. The dull-radiant, transparent-chalky, and dead-vivid pairs depend little upon chromaticity. Of all seven antonyms, only the soft-hard one turns out to be independent of the chromatic structure. © The Author(s) 2015.

  11. An environmentally compliant cerium-based conversion coating for aluminum protection

    NASA Astrophysics Data System (ADS)

    Lin, Xuan

    Chromate conversion coatings have been extensively used in the aircraft industry for the corrosion protection of aluminum alloys. Unfortunately, hexavalent chromium, which is a primary component in the chromating process, is a confirmed carcinogen. Because of rising remediation and disposal costs caused by increasingly strict regulations, the replacement of the traditional chromate conversion process is becoming a top priority in the metal finishing industry. This research focused on the electrodeposition of cerium-based coatings on 7075-T6 aluminum alloy in an electrolyte containing a cerium salt, an oxidizing agent and an organic solvent. The cerium-rich deposits were characterized by phase composition, oxidation state, coating thickness, surface morphology, deposition mechanism and polarization behavior. Chemical and electrochemical tests were utilized to compare the corrosion resistance between cerium-based coatings and chromate conversion coatings. To characterize and simulate the deposition process, a variety of approaches were utilized to study the oxidation states of cerium in various soluble and precipitated forms as a function of hydrogen peroxide and electrolyte pH. The pH ranges where the oxidation and reduction reactions dominate were determined. Further studies were performed to optimize the corrosion performance of cerium-based coatings and to understand the effects of electrolyte constituents and deposition parameters. The optimum levels for these variables were identified. A patent disclosure on the cerium-based coating process was made to the University of Missouri-Rolla and has now been officially filed with the U.S. Patent Office.

  12. Homologous Recombination Repair Protects Against Particulate Chromate-induced Chromosome Instability in Chinese Hamster Cells

    PubMed Central

    Stackpole, Megan M.; Wise, Sandra S.; Duzevik, Eliza Grlickova; Munroe, Ray C.; Thompson, W. Douglas; Thacker, John; Thompson, Larry H.; Hinz, John M.; Wise, John Pierce

    2008-01-01

    Particulate hexavalent chromium [Cr(VI)] compounds are well-established human carcinogens. Cr(VI)-induced tumors are characterized by chromosomal instability (CIN); however, the mechanisms of this effect are unknown. We investigated the hypothesis that homologous recombination (HR) repair of DNA double strand breaks protect cells from Cr(VI)-induced CIN by focusing on the XRCC3 and RAD51C genes, which play an important role in cellular resistance to DNA double strand breaks. We used Chinese hamster cells defective in each HR gene (irs3 for RAD51C and irs1SF for XRCC3) and compared with their wildtype parental and cDNA-complemented controls. We found that the intracellular Cr ion levels varied among the cell lines after particulate chromate treatment. Importantly, accounting for differences in Cr ion levels, we discovered that XRCC3 and RAD51C cells treated with lead chromate had increased cytotoxicity and chromosomal aberrations, relative to wild-type and cDNA-complimented cells. We also observed the emergence of high levels of chromatid exchanges in the two mutant cell lines. For example, 1 ug/cm2 lead chromate induced 20 and 32 exchanges in XRCC3- and RAD51C-deficient cells, respectively, whereas no exchanges were detected in the wildtype and cDNA-complemented cells. These observations suggest that HR protects cells from Cr(VI)-induced CIN, consistent with the ability of particulate Cr(VI) to induce double strand breaks. PMID:17662313

  13. The darkening of zinc yellow: XANES speciation of chromium in artist;s paints after light and chemical exposures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zanella, Luciana; Casadio, Francesca; Gray, Kimberly A.

    2012-03-14

    The color darkening of selected brushstrokes of the masterpiece A Sunday on La Grande Jatte - 1884 (by Georges Seurat) has been attributed to the alteration of the chromate pigment zinc yellow. The pigment originally displays a bright greenish-yellow color but may undergo, after aging, darkening to a dull, ocher tone. We used XANES to probe the oxidation state of Cr on paint reconstructions, and show that color changes are associated with the reduction of Cr(VI) to Cr(III). Paint mixtures containing the pigment and linseed oil to mimic mixtures used in La Grande Jatte were subjected to artificial aging inmore » the presence of light, SO{sub 2}, and variable air humidity - 50 and 90% relative humidity. High relative humidity led to the largest degree of Cr(VI) reduction whereas low relative humidity promoted light-induced alterations. These results are corroborated by visible reflectance measurements on the same laboratory samples and contribute to a better understanding of the chemical reactivity of chromate pigments, which are present in many historical works of art.« less

  14. Preparation of balanced trichromatic white phosphors for solid-state white lighting.

    PubMed

    Al-Waisawy, Sara; George, Anthony F; Jadwisienczak, Wojciech M; Rahman, Faiz

    2017-08-01

    High quality white light-emitting diodes (LEDs) employ multi-component phosphor mixtures to generate light of a high color rendering index (CRI). The number of distinct components in a typical phosphor mix usually ranges from two to four. Here we describe a systematic experimental technique for starting with phosphors of known chromatic properties and arriving at their respective proportions for creating a blended phosphor to produce light of the desired chromaticity. This method is applicable to both LED pumped and laser diode (LD) pumped white light sources. In this approach, the radiometric power in the down-converted luminescence of each phosphor is determined and that information is used to estimate the CIE chromaticity coordinate of light generated from the mixed phosphor. A suitable method for mixing multi-component phosphors is also described. This paper also examines the effect of light scattering particles in phosphors and their use for altering the spectral characteristics of LD- and LED-generated light. This is the only approach available for making high efficiency phosphor-converted single-color LEDs that emit light of wide spectral width. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Guiding characteristics of sunflower-type fiber

    NASA Astrophysics Data System (ADS)

    Liu, Exian; Yan, Bei; Tan, Wei; Xie, Jianlan; Ge, Rui; Liu, Jianjun

    2018-03-01

    In this paper, the guiding characteristics of sunflower-type fiber (SFF) with 6-fold rotational symmetry are investigated theoretically using finite element method (FEM). The behavior of single-mode propagation in SFF is verified. Numerical results reveal that, the cutoff ratio for endlessly single-mode propagation in SFF is 0.575 which is larger than that of photonic crystal fiber (PCF) and photonic quasi-crystal fiber (PQF). Moreover, SFF can present ultra-flattened near-zero chromatic dispersion, 0.249 ± 1.146 ps/nm/km, in a broadband of wavelength covering 1.20-1.84 μm over all the telecommunication wavelengths. In term of chromatic dispersion and confinement loss in the wavelength range from 1.00 to 2.00 μm, a comparison between SFF, PCF and PQF with same structure parameters is carried out. Importantly, the rotational symmetry, as a new manageable structure parameter beyond common air hole diameter and lattice constant, can be employed to manipulate the chromatic dispersion, confinement loss, effective mode area and non-linear coefficient and it dependences on these guiding characteristics are discussed in detail.

  16. Visual stimuli for the P300 brain-computer interface: a comparison of white/gray and green/blue flicker matrices.

    PubMed

    Takano, Kouji; Komatsu, Tomoaki; Hata, Naoki; Nakajima, Yasoichi; Kansaku, Kenji

    2009-08-01

    The white/gray flicker matrix has been used as a visual stimulus for the so-called P300 brain-computer interface (BCI), but the white/gray flash stimuli might induce discomfort. In this study, we investigated the effectiveness of green/blue flicker matrices as visual stimuli. Ten able-bodied, non-trained subjects performed Alphabet Spelling (Japanese Alphabet: Hiragana) using an 8 x 10 matrix with three types of intensification/rest flicker combinations (L, luminance; C, chromatic; LC, luminance and chromatic); both online and offline performances were evaluated. The accuracy rate under the online LC condition was 80.6%. Offline analysis showed that the LC condition was associated with significantly higher accuracy than was the L or C condition (Tukey-Kramer, p < 0.05). No significant difference was observed between L and C conditions. The LC condition, which used the green/blue flicker matrix was associated with better performances in the P300 BCI. The green/blue chromatic flicker matrix can be an efficient tool for practical BCI application.

  17. Chromated Arsenicals (CCA)

    EPA Pesticide Factsheets

    Chromated copper arsenate (CCA) is a wood preservative pesticide containing chromium, copper, and arsenic that protects wood against termites, fungi, mites and other pests that can degrade or threaten the integrity of wood products.

  18. Improvements in Ross type astrometric objectives

    NASA Technical Reports Server (NTRS)

    Baker, J.

    1971-01-01

    It is shown that aspheric deformations of the first and fourth elements of the four element Ross objective can be introduced to permit one to obtain improved color corrections for astrometric purposes. The usual monochromatic aberrations are as well corrected as for the standard Ross lens. In addition, one can eliminate or reduce additional aberrations, such as secondary spectrum, chromatic spherical aberration, chromatic coma and chromatic distortion. The resulting objectives are suitable for use as intermediate and long focus astrometric objectives covering large angle fields.

  19. Calculating Correlated Color Temperatures Across the Entire Gamut of Daylight and Skylight Chromaticities

    DTIC Science & Technology

    1999-09-20

    c o i b f t c c c c w n c s p t s Calculating correlated color temperatures across the entire gamut of daylight and skylight chromaticities Javier...temperature ~CCT!, yet existing equations for calculating CCT from chromaticity coordinates span only part of this range. To improve both the gamut and accuracy...00-1999 to 00-00-1999 4. TITLE AND SUBTITLE Calculating correlated color temperatures across the entire gamut of daylight and skylight

  20. Chelation in metal intoxication. VIII. Removal of chromium from organs of potassium chromate administered rats.

    PubMed

    Behari, J R; Tandon, S K

    1980-03-01

    Some polyaminocarboxylic acids were examined for their ability to mobilize chromium from certain vital organs, their subcellular fractions, and blood cells of potassium chromate administered rats. Hexamethylene 1,6-diamino tetraacetic acid (TDTA), triethylene tetramine hexaacetic acid (TTHA), and ethylene diamine di (O-hydroxylphenyl acetic acid) (EDDHA) may be useful in preventing or reducing chromate toxicity. No definite relationship could be observed between the structure of the chelating agents and their chromium-removing capacity.

  1. Investigation of corrosion protection performance of sol-gel surface treatments on AA2024-T3

    NASA Astrophysics Data System (ADS)

    Voevodin, Natalia Nikolajevna

    The dissertation research project addresses the technologically important problem of replacement of chromate based coatings for corrosion protection of aircraft. A review of corrosion processes in high-strength aluminum alloys indicated that the strengthening intermetallic precipitates provide local cathodic areas, which may initiate surface pitting. The mechanisms of chromate inhibition in these localized corrosion processes were identified. The environmental hazard of chromates was also highlighted, serves as the impetus for chromate coating replacement. Sol-gel coatings are shown as an excellent alternative, based on environment compliance, flexibility in the composition control, and reasonable costs. Several sol-gel coatings were formulated and applied to the surface of an AA2024-T3 alloy. The coating composition and bonding were analyzed with XPS and FTIR, surface morphology was studied with SEM and AFM, and corrosion protection properties were tested with EIS, PDS, salt water immersion, and salt-fog exposure. The results demonstrated that epoxy-zirconate sol-gel coatings can provide excellent barrier properties. A novel SVET technique was applied for studies of local electrochemical processes in the pitting formation. This technique was further refined in model studies of aluminum surfaces with artificially created local cathodic regions, experimental studies of chromate inhibition with pit formation, and pitting development studies in sol-gel coatings with artificially introduced defects. Mechanisms of pitting development and inhibition with the pit initiation and growth kinetics were established. The Zr-epoxy coatings are subjected to the pit development and undercutting in the absence of the corrosion inhibitors. Several organic and non-organic inhibitors were evaluated in the sol-gel coating composition. Organic inhibitors had a better compliance with sol-gel chemistry and were identified for future studies. Experiments were performed to verify that sol-gel coatings can be used as barrier layers in complex coating systems. The results clearly demonstrated that Zr-epoxy sol-gel coatings are a viable replacement for the currently used chromate-based surface treatments. This work expands the fundamental knowledge of chromate coating replacement with chromate-free sol-gel coatings and identifies possible ways to implement this goal.

  2. Newborns' Discrimination of Chromatic from Achromatic Stimuli.

    ERIC Educational Resources Information Center

    Adams, Russell J.; And Others

    1986-01-01

    Two experiments assessed the extent of newborns' ability to discriminate color. Results imply that newborns have some, albeit limited, capacity to discriminate chromatic from achromatic stimuli, and hence, are at least dichromats. (Author/DR)

  3. Spectral reflectance properties of electroplated and converted zinc for use as a solar selective coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.; Curtis, H. B.; Gianelos, L.

    1975-01-01

    The spectral reflectance properties of electroplated and chemically converted zinc were measured for both chromate and chloride conversion coatings. The reflectance properties were measured for various times of conversion and for conversion at various chromate concentrations. The values of absorptance, integrated over the solar spectrum, and of infrared emittance, integrated over black body radiation at 250 F were then calculated from the measured reflectance values. The interdependent variations of absorptance and infrared emittance were plotted. The results indicate that the optimum combination of the highest absorptance in the solar spectrum and the lowest emittance in the infrared of the converted electroplated zinc is produced by chromate conversion at 1/2 concentration of the standard NEOSTAR chromate black solution for 0.50 minute or by chloride conversion for 0.50 minute.

  4. Spectral reflectance properties of electroplated and converted zinc for use as a solar selective coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.; Curtis, H. B.; Gianelos, L.

    1975-01-01

    The spectral reflectance properties of electroplated and chemically converted zinc were measured for both chromate and chloride conversion coatings. The reflectance properties were measured for various times of conversion and for conversion at various chromate concentrations. The values of absorptance, alpha, integrated over the solar spectrum, and of infrared emittance, epsilon, integrated over black body radiation at 250 F were then calculated from the measured reflectance values. The interdependent variations of alpha and epsilon were plotted. The results indicate that the optimum combination of the highest absorptance in the solar spectrum and the lowest emittance in the infrared of the converted electroplated zinc is produced by chromate conversion at 1/2 concentration of the standard NEOSTAR chromate black solution for 0.50 minute or by chloride conversion for 0.50 minute.

  5. Design of measurement system of 3D surface profile based on chromatic confocal technology

    NASA Astrophysics Data System (ADS)

    Wang, An-su; Xie, Bin; Liu, Zi-wei

    2018-01-01

    Chromatic confocal 3D profilometer has widely used in science investigation and industry fields recently for its high precision, great measuring range and numerical surface characteristic. It can provide exact and omnidirectional solution for manufacture and research by 3D non-contact surface analysis technique. The article analyzes the principle of surface measurement with chromatic confocal technology, and provides the designing indicators and requirements of the confocal system. As the key component, the dispersive objective used to achieve longitudinal focus vibration with wavelength was designed. The objective disperses the focus of wavelength between 400 700 nm to 15 mm longitudinal range. With selected spectrometer, the resolution of chromatic confocal 3D profilometer is no more than 5 μm, which can meet needs for the high precision non-contact surface profile measurement.

  6. Applied optics. Multiwavelength achromatic metasurfaces by dispersive phase compensation.

    PubMed

    Aieta, Francesco; Kats, Mikhail A; Genevet, Patrice; Capasso, Federico

    2015-03-20

    The replacement of bulk refractive optical elements with diffractive planar components enables the miniaturization of optical systems. However, diffractive optics suffers from large chromatic aberrations due to the dispersion of the phase accumulated by light during propagation. We show that this limitation can be overcome with an engineered wavelength-dependent phase shift imparted by a metasurface, and we demonstrate a design that deflects three wavelengths by the same angle. A planar lens without chromatic aberrations at three wavelengths is also presented. Our designs are based on low-loss dielectric resonators, which introduce a dense spectrum of optical modes to enable dispersive phase compensation. The suppression of chromatic aberrations in metasurface-based planar photonics will find applications in lightweight collimators for displays, as well as chromatically corrected imaging systems. Copyright © 2015, American Association for the Advancement of Science.

  7. Ultra-low power high-dynamic range color pixel embedding RGB to r-g chromaticity transformation

    NASA Astrophysics Data System (ADS)

    Lecca, Michela; Gasparini, Leonardo; Gottardi, Massimo

    2014-05-01

    This work describes a novel color pixel topology that converts the three chromatic components from the standard RGB space into the normalized r-g chromaticity space. This conversion is implemented with high-dynamic range and with no dc power consumption, and the auto-exposure capability of the sensor ensures to capture a high quality chromatic signal, even in presence of very bright illuminants or in the darkness. The pixel is intended to become the basic building block of a CMOS color vision sensor, targeted to ultra-low power applications for mobile devices, such as human machine interfaces, gesture recognition, face detection. The experiments show that significant improvements of the proposed pixel with respect to standard cameras in terms of energy saving and accuracy on data acquisition. An application to skin color-based description is presented.

  8. Chromatic aberration of light focusing in hyperbolic anisotropic metamaterial made of metallic slit array.

    PubMed

    Guo, Kai; Liu, Jianlong; Zhang, Yan; Liu, Shutian

    2012-12-17

    The dispersion of a hyperbolic anisotropic metamaterial (HAM) and the chromatic aberration of light focusing in this kind of HAM are studied. The HAM is formed by alternately stacking metal and dielectric layers. The rules of materials and filling factors affecting the optical property of HAM are given. The chromatic aberration of light focusing is demonstrated both theoretically and numerically. By comparing the theory with the simulation results, the factors influencing the focal length, including the heat loss of material and low spatial frequency modes, are discussed. The investigation emphasizes the anomalous properties, such as chromatic aberration and low spatial frequency modes influencing focus position, of HAM compared with that in conventional lens. Based on the analysis, the possibility of using HAM to focus light with two different wavelengths at the same point is studied.

  9. Separating monocular and binocular neural mechanisms mediating chromatic contextual interactions.

    PubMed

    D'Antona, Anthony D; Christiansen, Jens H; Shevell, Steven K

    2014-04-17

    When seen in isolation, a light that varies in chromaticity over time is perceived to oscillate in color. Perception of that same time-varying light may be altered by a surrounding light that is also temporally varying in chromaticity. The neural mechanisms that mediate these contextual interactions are the focus of this article. Observers viewed a central test stimulus that varied in chromaticity over time within a larger surround that also varied in chromaticity at the same temporal frequency. Center and surround were presented either to the same eye (monocular condition) or to opposite eyes (dichoptic condition) at the same frequency (3.125, 6.25, or 9.375 Hz). Relative phase between center and surround modulation was varied. In both the monocular and dichoptic conditions, the perceived modulation depth of the central light depended on the relative phase of the surround. A simple model implementing a linear combination of center and surround modulation fit the measurements well. At the lowest temporal frequency (3.125 Hz), the surround's influence was virtually identical for monocular and dichoptic conditions, suggesting that at this frequency, the surround's influence is mediated primarily by a binocular neural mechanism. At higher frequencies, the surround's influence was greater for the monocular condition than for the dichoptic condition, and this difference increased with temporal frequency. Our findings show that two separate neural mechanisms mediate chromatic contextual interactions: one binocular and dominant at lower temporal frequencies and the other monocular and dominant at higher frequencies (6-10 Hz).

  10. Synthetic sea water - An improved stress corrosion test medium for aluminum alloys

    NASA Technical Reports Server (NTRS)

    Humphries, T. S.; Nelson, E. E.

    1973-01-01

    A major problem in evaluating the stress corrosion cracking resistance of aluminum alloys by alternate immersion in 3.5 percent salt (NaCl) water is excessive pitting corrosion. Several methods were examined to eliminate this problem and to find an improved accelerated test medium. These included the addition of chromate inhibitors, surface treatment of specimens, and immersion in synthetic sea water. The results indicate that alternate immersion in synthetic sea water is a very promising stress corrosion test medium. Neither chromate inhibitors nor surface treatment (anodize and alodine) of the aluminum specimens improved the performance of alternate immersion in 3.5 percent salt water sufficiently to be classified as an effective stress corrosion test method.

  11. Human region segmentation and description methods for domiciliary healthcare monitoring using chromatic methodology

    NASA Astrophysics Data System (ADS)

    Al-Temeemy, Ali A.

    2018-03-01

    A descriptor is proposed for use in domiciliary healthcare monitoring systems. The descriptor is produced from chromatic methodology to extract robust features from the monitoring system's images. It has superior discrimination capabilities, is robust to events that normally disturb monitoring systems, and requires less computational time and storage space to achieve recognition. A method of human region segmentation is also used with this descriptor. The performance of the proposed descriptor was evaluated using experimental data sets, obtained through a series of experiments performed in the Centre for Intelligent Monitoring Systems, University of Liverpool. The evaluation results show high recognition performance for the proposed descriptor in comparison to traditional descriptors, such as moments invariant. The results also show the effectiveness of the proposed segmentation method regarding distortion effects associated with domiciliary healthcare systems.

  12. Neurochemical responses to chromatic and achromatic stimuli in the human visual cortex.

    PubMed

    Bednařík, Petr; Tkáč, Ivan; Giove, Federico; Eberly, Lynn E; Deelchand, Dinesh K; Barreto, Felipe R; Mangia, Silvia

    2018-02-01

    In the present study, we aimed at determining the metabolic responses of the human visual cortex during the presentation of chromatic and achromatic stimuli, known to preferentially activate two separate clusters of neuronal populations (called "blobs" and "interblobs") with distinct sensitivity to color or luminance features. Since blobs and interblobs have different cytochrome-oxidase (COX) content and micro-vascularization level (i.e., different capacities for glucose oxidation), different functional metabolic responses during chromatic vs. achromatic stimuli may be expected. The stimuli were optimized to evoke a similar load of neuronal activation as measured by the bold oxygenation level dependent (BOLD) contrast. Metabolic responses were assessed using functional 1 H MRS at 7 T in 12 subjects. During both chromatic and achromatic stimuli, we observed the typical increases in glutamate and lactate concentration, and decreases in aspartate and glucose concentration, that are indicative of increased glucose oxidation. However, within the detection sensitivity limits, we did not observe any difference between metabolic responses elicited by chromatic and achromatic stimuli. We conclude that the higher energy demands of activated blobs and interblobs are supported by similar increases in oxidative metabolism despite the different capacities of these neuronal populations.

  13. Chromatic and Achromatic Spatial Resolution of Local Field Potentials in Awake Cortex.

    PubMed

    Jansen, Michael; Li, Xiaobing; Lashgari, Reza; Kremkow, Jens; Bereshpolova, Yulia; Swadlow, Harvey A; Zaidi, Qasim; Alonso, Jose-Manuel

    2015-10-01

    Local field potentials (LFPs) have become an important measure of neuronal population activity in the brain and could provide robust signals to guide the implant of visual cortical prosthesis in the future. However, it remains unclear whether LFPs can detect weak cortical responses (e.g., cortical responses to equiluminant color) and whether they have enough visual spatial resolution to distinguish different chromatic and achromatic stimulus patterns. By recording from awake behaving macaques in primary visual cortex, here we demonstrate that LFPs respond robustly to pure chromatic stimuli and exhibit ∼2.5 times lower spatial resolution for chromatic than achromatic stimulus patterns, a value that resembles the ratio of achromatic/chromatic resolution measured with psychophysical experiments in humans. We also show that, although the spatial resolution of LFP decays with visual eccentricity as is also the case for single neurons, LFPs have higher spatial resolution and show weaker response suppression to low spatial frequencies than spiking multiunit activity. These results indicate that LFP recordings are an excellent approach to measure spatial resolution from local populations of neurons in visual cortex including those responsive to color. © The Author 2014. Published by Oxford University Press.

  14. Dying for Good: Virus-Bacterium Biofilm Co-evolution Enhances Environmental Fitness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Hongjun; Squier, Thomas C.; Long, Philip E.

    Commonly used in biotechnology applications, filamentous M13 phage are non-lytic viruses that infect E. coli and other bacteria, with the potential to promote horizontal gene transfer in natural populations with synthetic biology implications for engineering community systems. Using the E. coli strain TG1, we have investigated how a selective pressure involving elevated levels of toxic chromate, mimicking that found in some superfund sites, alters population dynamics following infection with either wild-type M13 phage or an M13-phage encoding a chromate reductase (Gh-ChrR) capable of the reductive immobilization of chromate (ie, M13-phageGh-ChrR). In the absence of a selective pressure, M13-phage infection resultsmore » in a reduction in bacterial growth rate; in comparison, in the presence of chromate there are substantial increases in both cellular killing and biomass formation following infection of E. coli strain TG1with M13-phageGh-ChrR that is dependent on chromate-reductase activity. These results are discussed in terms of community structures that facilitate lateral gene transfer of beneficial traits that enhance phage replication, infectivity, and stability against environmental change.« less

  15. Lumen degradation and chromaticity shift in glass and silicone based high-power phosphor-converted white-emitting diodes under thermal tests

    NASA Astrophysics Data System (ADS)

    Cheng, Wood-Hi; Tsai, Chun-Chin; Wang, Jimmy

    2011-10-01

    The lumen degradation and chromaticity shift in glass and silicone based high-power phosphor-converted white-emitting diodes (PC-WLEDs) under accelerated thermal tests at 150°C, 200°C, and 250°C are presented and compared. The glass based PC-WLEDs exhibited better thermal stability than the silicone by 4.8 time reductions in lumen loss 6.8 time reductions in chromaticity shift at 250°C, respectively. The mean-time-to-failure (MTTF) evaluation of glass and silicone based high-power PC-WLEDs in accelerated thermal tests is also presented and compared. The results showed that the glass based PC-WLEDs exhibited higher MTTF than the silicone by 7.53 times in lumen loss and 14.4 times in chromaticity shift at 250°C, respectively. The thermal performance of lumen, chromaticity, and MTTF investigations demonstrated that the thermal stability of the glass based PC-WLEDs were better than the silicone. A better thermal stability phosphor layer of glass as encapsulation material may be beneficial to the many applications where the LED modules with high power and high reliability are demanded.

  16. Chemical Reductive Treatment of Groundwater Chromate and Chlorinated Ethenes: Tests at Two Field Sites

    EPA Science Inventory

    Both hexavalent chromium (Cr(VI)) and chlorinated ethenes such as tetrachloroethene (PCE) are common groundwater contaminants. A pump-and-treat approach to remedy them usually is not satisfactory with respect to effectiveness and cost. Effective treatment technologies generally...

  17. Longitudinal measurement of chromatic dispersion along an optical fiber transmission system with a new correction factor

    NASA Astrophysics Data System (ADS)

    Abbasi, Madiha; Imran Baig, Mirza; Shafique Shaikh, Muhammad

    2013-12-01

    At present existence OTDR based techniques have become a standard practice for measuring chromatic dispersion distribution along an optical fiber transmission link. A constructive measurement technique has been offered in this paper, in which a four wavelength bidirectional optical time domain reflectometer (OTDR) has been used to compute the chromatic dispersion allocation beside an optical fiber transmission system. To improve the correction factor a novel formulation has been developed, which leads to an enhanced and defined measurement. The investigational outcomes obtained are in good harmony.

  18. Commercial-Off-the-Shelf (COTS), Volatile Organic Compounds (VOCs) and Hazardous Air Pollutants (HAPs)-Free, Non-Chromate Low Temperature Powder Coating (LTPC) System for United States Air Force use (PHASE II )

    DTIC Science & Technology

    2017-09-12

    and Hazardous Air Pollutants (HAPs)-Free, non -chromate low temperature powder coating (LTPC) system for United States Air Force use PHASE II PR...required to support and successfully complete this effort. 1.1 Objective(s). The Contractor shall be required to demonstrate a non -chromate...5.0 General Information 5.1 Continuation of Mission-Essential Services During a Crisis. The Functional Commander (FC) or civilian equivalent has

  19. Chromatic and achromatic monocular deprivation produce separable changes of eye dominance in adults.

    PubMed

    Zhou, Jiawei; Reynaud, Alexandre; Kim, Yeon Jin; Mullen, Kathy T; Hess, Robert F

    2017-11-29

    Temporarily depriving one eye of its input, in whole or in part, results in a transient shift in eye dominance in human adults, with the patched eye becoming stronger and the unpatched eye weaker. However, little is known about the role of colour contrast in these behavioural changes. Here, we first show that the changes in eye dominance and contrast sensitivity induced by monocular eye patching affect colour and achromatic contrast sensitivity equally. We next use dichoptic movies, customized and filtered to stimulate the two eyes differentially. We show that a strong imbalance in achromatic contrast between the eyes, with no colour content, also produces similar, unselective shifts in eye dominance for both colour and achromatic contrast sensitivity. Interestingly, if this achromatic imbalance is paired with similar colour contrast in both eyes, the shift in eye dominance is selective, affecting achromatic but not chromatic contrast sensitivity and revealing a dissociation in eye dominance for colour and achromatic image content. On the other hand, a strong imbalance in chromatic contrast between the eyes, with no achromatic content, produces small, unselective changes in eye dominance, but if paired with similar achromatic contrast in both eyes, no changes occur. We conclude that perceptual changes in eye dominance are strongly driven by interocular imbalances in achromatic contrast, with colour contrast having a significant counter balancing effect. In the short term, eyes can have different dominances for achromatic and chromatic contrast, suggesting separate pathways at the site of these neuroplastic changes. © 2017 The Author(s).

  20. Color calibration and fusion of lens-free and mobile-phone microscopy images for high-resolution and accurate color reproduction

    NASA Astrophysics Data System (ADS)

    Zhang, Yibo; Wu, Yichen; Zhang, Yun; Ozcan, Aydogan

    2016-06-01

    Lens-free holographic microscopy can achieve wide-field imaging in a cost-effective and field-portable setup, making it a promising technique for point-of-care and telepathology applications. However, due to relatively narrow-band sources used in holographic microscopy, conventional colorization methods that use images reconstructed at discrete wavelengths, corresponding to e.g., red (R), green (G) and blue (B) channels, are subject to color artifacts. Furthermore, these existing RGB colorization methods do not match the chromatic perception of human vision. Here we present a high-color-fidelity and high-resolution imaging method, termed “digital color fusion microscopy” (DCFM), which fuses a holographic image acquired at a single wavelength with a color-calibrated image taken by a low-magnification lens-based microscope using a wavelet transform-based colorization method. We demonstrate accurate color reproduction of DCFM by imaging stained tissue sections. In particular we show that a lens-free holographic microscope in combination with a cost-effective mobile-phone-based microscope can generate color images of specimens, performing very close to a high numerical-aperture (NA) benchtop microscope that is corrected for color distortions and chromatic aberrations, also matching the chromatic response of human vision. This method can be useful for wide-field imaging needs in telepathology applications and in resource-limited settings, where whole-slide scanning microscopy systems are not available.

  1. Color calibration and fusion of lens-free and mobile-phone microscopy images for high-resolution and accurate color reproduction

    PubMed Central

    Zhang, Yibo; Wu, Yichen; Zhang, Yun; Ozcan, Aydogan

    2016-01-01

    Lens-free holographic microscopy can achieve wide-field imaging in a cost-effective and field-portable setup, making it a promising technique for point-of-care and telepathology applications. However, due to relatively narrow-band sources used in holographic microscopy, conventional colorization methods that use images reconstructed at discrete wavelengths, corresponding to e.g., red (R), green (G) and blue (B) channels, are subject to color artifacts. Furthermore, these existing RGB colorization methods do not match the chromatic perception of human vision. Here we present a high-color-fidelity and high-resolution imaging method, termed “digital color fusion microscopy” (DCFM), which fuses a holographic image acquired at a single wavelength with a color-calibrated image taken by a low-magnification lens-based microscope using a wavelet transform-based colorization method. We demonstrate accurate color reproduction of DCFM by imaging stained tissue sections. In particular we show that a lens-free holographic microscope in combination with a cost-effective mobile-phone-based microscope can generate color images of specimens, performing very close to a high numerical-aperture (NA) benchtop microscope that is corrected for color distortions and chromatic aberrations, also matching the chromatic response of human vision. This method can be useful for wide-field imaging needs in telepathology applications and in resource-limited settings, where whole-slide scanning microscopy systems are not available. PMID:27283459

  2. Color calibration and fusion of lens-free and mobile-phone microscopy images for high-resolution and accurate color reproduction.

    PubMed

    Zhang, Yibo; Wu, Yichen; Zhang, Yun; Ozcan, Aydogan

    2016-06-10

    Lens-free holographic microscopy can achieve wide-field imaging in a cost-effective and field-portable setup, making it a promising technique for point-of-care and telepathology applications. However, due to relatively narrow-band sources used in holographic microscopy, conventional colorization methods that use images reconstructed at discrete wavelengths, corresponding to e.g., red (R), green (G) and blue (B) channels, are subject to color artifacts. Furthermore, these existing RGB colorization methods do not match the chromatic perception of human vision. Here we present a high-color-fidelity and high-resolution imaging method, termed "digital color fusion microscopy" (DCFM), which fuses a holographic image acquired at a single wavelength with a color-calibrated image taken by a low-magnification lens-based microscope using a wavelet transform-based colorization method. We demonstrate accurate color reproduction of DCFM by imaging stained tissue sections. In particular we show that a lens-free holographic microscope in combination with a cost-effective mobile-phone-based microscope can generate color images of specimens, performing very close to a high numerical-aperture (NA) benchtop microscope that is corrected for color distortions and chromatic aberrations, also matching the chromatic response of human vision. This method can be useful for wide-field imaging needs in telepathology applications and in resource-limited settings, where whole-slide scanning microscopy systems are not available.

  3. Miniature low voltage beam systems producable by combined lithographies

    NASA Astrophysics Data System (ADS)

    Koops, Hans W. P.; Munro, Eric; Rouse, John; Kretz, Johannes; Rudolph, Michael; Weber, Markus; Dahm, Gerold

    The project of a miniaturized vacuum microelectronic 100 GHz switch is described. It implies the development of a field emission electron gun as well as the investigation of miniaturized lenses and deflectors. Electrostatic elements are designed and developed for this application. Connector pads and wiring pattern are created by conventional electron beam lithography and a lift-off or etching process. Wire and other 3-dimensional structures are grown using electron beam induced deposition. This additive lithography allows to form electrodes and resistors of a preset conductivity. The scanning electron microscope features positioning the structures with nm precision. An unconventional lithography system is used that is capable of controlling the pixel dwell time within a shape with different time functions. With this special function 3-dimensional structures can be generated like free standing square shaped electrodes. The switch is built by computer controlled additive lithography avoiding assembly from parts. Lenses of micrometer dimensions were investigated with numerical electron optics programs computing the 3-dimensional potential and field distribution. From the extracted axial field distribution the electron optic characteristic parameters, like focal length, chromatic and spherical aberration, were calculated for various lens excitations. The analysis reveals that miniaturized optics for low energy electrons, as low as 30 eV, are diffraction limited. For a lens with 2 μm focal length, a chromatic aberration disc of 1 nm contributes to 12 nm diffraction disc. The spherical aberration blurs the probe by 0.02 nm, assuming an aperture of 0.01 rad. Employing hydrogen ions at 100 V, a probe diameter of 0.3 nm generated by chromatic aberration is possible. Miniaturized electron optical probe forming systems and imaging systems can be constructed with those lenses. Its application as lithography systems with massive parallel beams can be forseen.

  4. Visual Perception and Reading: New Clues to Patterns of Dysfunction Across Multiple Visual Channels in Developmental Dyslexia.

    PubMed

    Pina Rodrigues, Ana; Rebola, José; Jorge, Helena; Ribeiro, Maria José; Pereira, Marcelino; van Asselen, Marieke; Castelo-Branco, Miguel

    2017-01-01

    The specificity of visual channel impairment in dyslexia has been the subject of much controversy. The purpose of this study was to determine if a differential pattern of impairment can be verified between visual channels in children with developmental dyslexia, and in particular, if the pattern of deficits is more conspicuous in tasks where the magnocellular-dorsal system recruitment prevails. Additionally, we also aimed at investigating the association between visual perception thresholds and reading. In the present case-control study, we compared perception thresholds of 33 children diagnosed with developmental dyslexia and 34 controls in a speed discrimination task, an achromatic contrast sensitivity task, and a chromatic contrast sensitivity task. Moreover, we addressed the correlation between the different perception thresholds and reading performance, as assessed by means of a standardized reading test (accuracy and fluency). Group comparisons were performed by the Mann-Whitney U test, and Spearman's rho was used as a measure of correlation. Results showed that, when compared to controls, children with dyslexia were more impaired in the speed discrimination task, followed by the achromatic contrast sensitivity task, with no impairment in the chromatic contrast sensitivity task. These results are also consistent with the magnocellular theory since the impairment profile of children with dyslexia in the visual threshold tasks reflected the amount of magnocellular-dorsal stream involvement. Moreover, both speed and achromatic thresholds were significantly correlated with reading performance, in terms of accuracy and fluency. Notably, chromatic contrast sensitivity thresholds did not correlate with any of the reading measures. Our evidence stands in favor of a differential visual channel deficit in children with developmental dyslexia and contributes to the debate on the pathophysiology of reading impairments.

  5. Color constancy by characterization of illumination chromaticity

    NASA Astrophysics Data System (ADS)

    Nikkanen, Jarno T.

    2011-05-01

    Computational color constancy algorithms play a key role in achieving desired color reproduction in digital cameras. Failure to estimate illumination chromaticity correctly will result in invalid overall colour cast in the image that will be easily detected by human observers. A new algorithm is presented for computational color constancy. Low computational complexity and low memory requirement make the algorithm suitable for resource-limited camera devices, such as consumer digital cameras and camera phones. Operation of the algorithm relies on characterization of the range of possible illumination chromaticities in terms of camera sensor response. The fact that only illumination chromaticity is characterized instead of the full color gamut, for example, increases robustness against variations in sensor characteristics and against failure of diagonal model of illumination change. Multiple databases are used in order to demonstrate the good performance of the algorithm in comparison to the state-of-the-art color constancy algorithms.

  6. Focal plane wavefront sensor achromatization: The multireference self-coherent camera

    NASA Astrophysics Data System (ADS)

    Delorme, J. R.; Galicher, R.; Baudoz, P.; Rousset, G.; Mazoyer, J.; Dupuis, O.

    2016-04-01

    Context. High contrast imaging and spectroscopy provide unique constraints for exoplanet formation models as well as for planetary atmosphere models. But this can be challenging because of the planet-to-star small angular separation (<1 arcsec) and high flux ratio (>105). Recently, optimized instruments like VLT/SPHERE and Gemini/GPI were installed on 8m-class telescopes. These will probe young gazeous exoplanets at large separations (≳1 au) but, because of uncalibrated phase and amplitude aberrations that induce speckles in the coronagraphic images, they are not able to detect older and fainter planets. Aims: There are always aberrations that are slowly evolving in time. They create quasi-static speckles that cannot be calibrated a posteriori with sufficient accuracy. An active correction of these speckles is thus needed to reach very high contrast levels (>106-107). This requires a focal plane wavefront sensor. Our team proposed a self coherent camera, the performance of which was demonstrated in the laboratory. As for all focal plane wavefront sensors, these are sensitive to chromatism and we propose an upgrade that mitigates the chromatism effects. Methods: First, we recall the principle of the self-coherent camera and we explain its limitations in polychromatic light. Then, we present and numerically study two upgrades to mitigate chromatism effects: the optical path difference method and the multireference self-coherent camera. Finally, we present laboratory tests of the latter solution. Results: We demonstrate in the laboratory that the multireference self-coherent camera can be used as a focal plane wavefront sensor in polychromatic light using an 80 nm bandwidth at 640 nm (bandwidth of 12.5%). We reach a performance that is close to the chromatic limitations of our bench: 1σ contrast of 4.5 × 10-8 between 5 and 17 λ0/D. Conclusions: The performance of the MRSCC is promising for future high-contrast imaging instruments that aim to actively minimize the speckle intensity so as to detect and spectrally characterize faint old or light gaseous planets.

  7. Chromatic line-profile tomography to reveal exoplanetary atmospheres: application to HD 189733b

    NASA Astrophysics Data System (ADS)

    Borsa, F.; Rainer, M.; Poretti, E.

    2016-05-01

    Context. Transmission spectroscopy can be used to constrain the properties of exoplanetary atmospheres. During a transit, the light blocked from the atmosphere of the planet leaves an imprint in the light coming from the star. This has been shown for many exoplanets with both photometry and spectroscopy, using different analysis methods. Aims: We test chromatic line-profile tomography as a new tool to investigate exoplanetary atmospheres. The signal imprinted on the cross-correlation function (CCF) by a planet transiting its star is dependent on the planet-to-star radius ratio. We want to verify whether the precision reachable on the CCF obtained from a subset of the spectral orders of the HARPS spectrograph is high enough to determine the radius of a planet at different wavelengths. Methods: We analyze HARPS archival data of three transits of HD 189733b. We divide the HARPS spectral range into seven broadbands, calculating for each band the ratio between the area of the out-of-transit CCF and the area of the signal imprinted by the planet on it during the full part of the transit. We take into account the effect of the limb darkening using the theoretical coefficients of a linear law. Averaging the results of three different transits allows us to obtain a good-quality broadband transmission spectrum of HD 189733b with a greater precision than that of the chromatic Rossiter McLaughlin effect. Results: We proved that chromatic line-profile tomography is an interesting way to reveal broadband transmission spectra of exoplanets: our analysis of the atmosphere of HD 189733b is in agreement with other ground- and space-based observations. The independent analysis of different transits emphasizes the probability that stellar activity plays a role in the extracted transmission spectrum. Therefore, care should be taken when claiming that Rayleigh scattering is present in the atmosphere of exoplanets orbiting active stars using only one transit.

  8. The effect of longitudinal chromatic aberration on the lag of accommodation and depth of field.

    PubMed

    Jaskulski, Mateusz; Marín-Franch, Iván; Bernal-Molina, Paula; López-Gil, Norberto

    2016-11-01

    Longitudinal chromatic aberration is present in all states of accommodation and may play a role in the accommodation response and the emmetropisation process. We study the change of the depth of field (DOFi) with the state of accommodation, taking into account the longitudinal chromatic aberration. Subjective DOFi was defined as the range of defocus beyond which the blur of the target (one line of optotypes of 0.1 logMAR shown on a black-and-white microdisplay, seen through different colour filters) was perceived as objectionable. The subject's eye was paralysed and different, previously-measured accommodative states (corresponding to the accommodative demands of 0D, 2D and 4D) were simulated with a deformable mirror. Different colour conditions (monochromatic red, green and blue and polychromatic (white) were tested. The DOFi was measured subjectively, using a motorised Badal system. Taking as reference the average accommodative response for the white stimulus, the blue response exhibits on average a lead of 0.45 ± 0.09D, the green a negligible lead of 0.07 ± 0.02D and red a lag of 0.49 ± 0.10D. The monochromatic DOFi, calculated by averaging DOFi over the red, green and blue colour conditions for each accommodative demand was 1.10 ± 0.10D for 0D, 1.20 ± 0.08D for 2D, and 1.26 ± 0.40D for 4D. The polychromatic white DOFi were greater than the average monochromatic DOFi by 19%, 9% and 14% for 0D, 2D, and 4D of accommodative demand, respectively. The longitudinal chromatic aberration causes a dioptric shift of the monochromatic accommodation response. The study did not reveal this shift to depend on the accommodative demand or to have an effect on the DOFi. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.

  9. Macular pigment and its contribution to visual performance and experience

    PubMed Central

    Loughman, James; Davison, Peter A.; Nolan, John M.; Akkali, Mukunda C.; Beatty, Stephen

    2010-01-01

    There is now a consensus, based on histological, biochemical and spectral absorption data, that the yellow colour observed at the macula lutea is a consequence of the selective accumulation of dietary xanthophylls in the central retina of the living eye. Scientific research continues to explore the function(s) of MP in the human retina, with two main hypotheses premised on its putative capacity to (1) protect the retina from (photo)-oxidative damage by means of its optical filtration and/or antioxidant properties, the so-called protective hypothesis and (2) influence the quality of visual performance by means of selective short wavelength light absorption prior to photoreceptor light capture, thereby attenuating the effects of chromatic aberration and light scatter, the so-called acuity and visibility hypotheses. The current epidemic of age-related macular degeneration has directed researchers to investigate the protective hypothesis of MP, while there has been a conspicuous lack of work designed to investigate the role of MP in visual performance. The aim of this review is to present and critically appraise the current literature germane to the contribution of MP, if any, to visual performance and experience.

  10. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys

    PubMed Central

    Hass, Charles A.; Angueyra, Juan M.; Lindbloom-Brown, Zachary; Rieke, Fred; Horwitz, Gregory D.

    2015-01-01

    Chromatic sensitivity cannot exceed limits set by noise in the cone photoreceptors. To determine how close neurophysiological and psychophysical chromatic sensitivity come to these limits, we developed a parameter-free model of stimulus encoding in the cone outer segments, and we compared the sensitivity of the model to the psychophysical sensitivity of monkeys performing a detection task and to the sensitivity of individual V1 neurons. Modeled cones had a temporal impulse response and a noise power spectrum that were derived from in vitro recordings of macaque cones, and V1 recordings were made during performance of the detection task. The sensitivity of the simulated cone mosaic, the V1 neurons, and the monkeys were tightly yoked for low-spatiotemporal-frequency isoluminant modulations, indicating high-fidelity signal transmission for this class of stimuli. Under the conditions of our experiments and the assumptions for our model, the signal-to-noise ratio for these stimuli dropped by a factor of ∼3 between the cones and perception. Populations of weakly correlated V1 neurons narrowly exceeded the monkeys' chromatic sensitivity but fell well short of the cones' chromatic sensitivity, suggesting that most of the behavior-limiting noise lies between the cone outer segments and the output of V1. The sensitivity gap between the cones and behavior for achromatic stimuli was larger than for chromatic stimuli, indicating greater postreceptoral noise. The cone mosaic model provides a means to compare visual sensitivity across disparate stimuli and to identify sources of noise that limit visual sensitivity. PMID:26523737

  11. Chromatic detection from cone photoreceptors to V1 neurons to behavior in rhesus monkeys.

    PubMed

    Hass, Charles A; Angueyra, Juan M; Lindbloom-Brown, Zachary; Rieke, Fred; Horwitz, Gregory D

    2015-01-01

    Chromatic sensitivity cannot exceed limits set by noise in the cone photoreceptors. To determine how close neurophysiological and psychophysical chromatic sensitivity come to these limits, we developed a parameter-free model of stimulus encoding in the cone outer segments, and we compared the sensitivity of the model to the psychophysical sensitivity of monkeys performing a detection task and to the sensitivity of individual V1 neurons. Modeled cones had a temporal impulse response and a noise power spectrum that were derived from in vitro recordings of macaque cones, and V1 recordings were made during performance of the detection task. The sensitivity of the simulated cone mosaic, the V1 neurons, and the monkeys were tightly yoked for low-spatiotemporal-frequency isoluminant modulations, indicating high-fidelity signal transmission for this class of stimuli. Under the conditions of our experiments and the assumptions for our model, the signal-to-noise ratio for these stimuli dropped by a factor of ∼3 between the cones and perception. Populations of weakly correlated V1 neurons narrowly exceeded the monkeys' chromatic sensitivity but fell well short of the cones' chromatic sensitivity, suggesting that most of the behavior-limiting noise lies between the cone outer segments and the output of V1. The sensitivity gap between the cones and behavior for achromatic stimuli was larger than for chromatic stimuli, indicating greater postreceptoral noise. The cone mosaic model provides a means to compare visual sensitivity across disparate stimuli and to identify sources of noise that limit visual sensitivity.

  12. Lung Inflammation, Injury, and Proliferative Response after Repetitive Particulate Hexavalent Chromium Exposure

    PubMed Central

    Beaver, Laura M.; Stemmy, Erik J.; Schwartz, Arnold M.; Damsker, Jesse M.; Constant, Stephanie L.; Ceryak, Susan M.; Patierno, Steven R.

    2009-01-01

    Background Chronic inflammation is implicated in the development of several human cancers, including lung cancer. Certain particulate hexavalent chromium [Cr(VI)] compounds are well-documented human respiratory carcinogens that release genotoxic soluble chromate and are associated with fibrosis, fibrosarcomas, adenocarcinomas, and squamous cell carcinomas of the lung. Despite this, little is known about the pathologic injury and immune responses after repetitive exposure to particulate chromates. Objectives In this study we investigated the lung injury, inflammation, proliferation, and survival signaling responses after repetitive exposure to particulate chromate. Methods BALB/c mice were repetitively treated with particulate basic zinc chromate or saline using an intranasal exposure regimen. We assessed lungs for Cr(VI)-induced changes by bronchoalveolar lavage, histologic examination, and immunohistochemistry. Results Single exposure to Cr(VI) resulted in inflammation of lung tissue that persists for up to 21 days. Repetitive Cr(VI) exposure induced a neutrophilic inflammatory airway response 24 hr after each treatment. Neutrophils were subsequently replaced by increasing numbers of macrophages by 5 days after treatment. Repetitive Cr(VI) exposure induced chronic peribronchial inflammation with alveolar and interstitial pneumonitis dominated by lymphocytes and macrophages. Moreover, chronic toxic mucosal injury was observed and accompanied by increased airway pro-matrix metalloprotease-9. Injury and inflammation correlated with airways becoming immunoreactive for phosphorylation of the survival signaling protein Akt and the proliferation marker Ki-67. We observed a reactive proliferative response in epithelial cells lining airways of chromate-exposed animals. Conclusions These data illustrate that repetitive exposure to particulate chromate induces chronic injury and an inflammatory microenvironment that may promote Cr(VI) carcinogenesis. PMID:20049209

  13. [Chromaticity and optical spectrum colorimetry of the tongue color in different syndromes of primary hepatic carcinoma].

    PubMed

    Xu, Ying; Zeng, Chang-chun; Cai, Xiu-yu; Guo, Rong-ping; Nie, Guang; Jin, Ying

    2012-11-01

    In this study, the optical data of tongue color of different syndromes in primary hepatic carcinoma (PHC) were detected by optical spectrum colorimetry, and the chromaticity of tongue color was compared and analyzed. The tongue color characteristics of different syndromes in PHC and the relationship between different syndromes and tongue color were also investigated. Tongue color data from 133 eligible PHC patients were collected by optical spectrum colorimetry and the patients were divided into 4 syndrome groups according to their clinical features. The syndrome groups were liver depression and spleen deficiency (LDSD), accumulation of damp-heat (ADH), deficiency of liver and kidney yin (DLKY), and qi stagnation and blood stasis (QSBS). The variation characteristics of chromaticity coordinates, dominant wavelength, excitation purity and the distribution in the International Commission on Illumination (CIE) LAB uniform color space were measured. At the same time, the differences of overall chromatism, clarity, chroma, saturation and hue were also calculated and analyzed. PHC patients in different syndrome groups exhibited differences in chromaticity coordinates. The dominant wavelength of QSBS was distinctly different from that of the other 3 syndromes. Excitation purity in the syndromes of LDSD, ADH and DLKY showed gradual increases (P<0.01). Different syndromes in the CIE LAB color three-dimensional space showed differences in tongue color distribution areas. The CIE hue-angle value of QSBS was negative, and different from that of the other 3 syndromes (P<0.01). CIE chroma in the syndromes of LDSD, ADH and DLKY showed gradual increases (P<0.01), the same as excitation purity. In the comparison of chromatism, tongue color variations in different syndromes were quantified by human observation. This study shows that tongue color diagnosis according to the syndrome classifications of traditional Chinese medicine can be quantified with optical spectrum colorimetry technology. Different syndromes in PHC exhibit distinct chromatisms of tongue color through the calculation and analysis of chromaticity parameters of CIE, combined with colorimetric system and CIE LAB color space, and these are consistent with the characteristics of clinical tongue color. Applying optical spectrum colorimetry technology to tongue color differentiation has the potential to serve as a reference point in standardizing traditional Chinese medicine syndrome classification in PHC.

  14. White-emissive tandem-type hybrid organic/polymer diodes with (0.33, 0.33) chromaticity coordinates.

    PubMed

    Guo, Tzung-Fang; Wen, Ten-Chin; Huang, Yi-Shun; Lin, Ming-Wei; Tsou, Chuan-Cheng; Chung, Chia-Tin

    2009-11-09

    This study reports fabrication of white-emissive, tandem-type, hybrid organic/polymer light-emitting diodes (O/PLED). The tandem devices are made by stacking a blue-emissive OLED on a yellow-emissive phenyl-substituted poly(para-phenylene vinylene) copolymer-based PLED and applying an organic oxide/Al/molybdenum oxide (MoO(3)) complex structure as a connecting structure or charge-generation layer (CGL). The organic oxide/Al/MoO(3) CGL functions as an effective junction interface for the transport and injection of opposite charge carriers through the stacked configuration. The electroluminescence (EL) spectra of the tandem-type devices can be tuned by varying the intensity of the emission in each emissive component to yield the visible-range spectra from 400 to 750 nm, with Commission Internationale de l'Eclairage chromaticity coordinates of (0.33, 0.33) and a high color rendering capacity as used for illumination. The EL spectra also exhibit good color stability under various bias conditions. The tandem-type device of emission with chromaticity coordinates, (0.30, 0.31), has maximum brightness and luminous efficiency over 25,000 cd/m(2) and approximately 4.2 cd/A, respectively.

  15. Effect of Annealing Time of YAG:Ce3+ Phosphor on White Light Chromaticity Values

    NASA Astrophysics Data System (ADS)

    Abd, Husnen R.; Hassan, Z.; Ahmed, Naser M.; Almessiere, Munirah Abdullah; Omar, A. F.; Alsultany, Forat H.; Sabah, Fayroz A.; Osman, Ummu Shuhada

    2018-02-01

    Yttrium and aluminium nitrate phosphors doped with cerium nitrate and mixed with urea (fuel) are prepared by using microwave-induced combustion synthesis according to the formula Y(3-0.06)Al5O12:0.06Ce3+ (YAG:Ce3+) to produce white light emitting diodes by conversion from blue indium gallium nitride-light emitting diode chips. The sintering time with fixed temperature (1050°C) for phosphor powder was optimized and found to be 5 h. The crystallinity, structure, chemical composition, luminescent properties with varying currents densities and chromaticity were characterized by x-ray diffraction, field emission-scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, photoluminescence emission, electroluminescence and standard CIE 1931 chromaticity diagram, respectively. The energy levels of Ce3+ in YAG were discussed based on its absorption and excitation spectra. The results show that the obtained YAG:Ce3+ phosphor sintered for 5 h has good crystallinity with pure phase, low agglomerate with spherical shaped particles and strong yellow emission, offering cool-white LED with tuneable correlated color temperature and a good color rendering index compared to those prepared by sintering for 2 h and as-prepared phosphor powders.

  16. Toxicity of sodium chromate and 3,4-dichloroaniline to crustaceans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van der Meer, C.; Teunissen, C.; Boog, T.F.M.

    1988-02-01

    Small adult and larval crustaceans are important components of a number of food webs. Therefore, it is important on the one hand to determine the sensitivity of these crustaceans to environmental contaminants and on the other hand to select the most sensitive species as test organisms to help establish the permissible contamination. In brackish water adults as well as larvae of the species Palaemonetes pugio and Uca pugilator have been most frequently investigated. These species can also be studied in sea water. The marine species Carcinus maenas, Crangon septemspinosa and Homarus americanus have also been studied relatively intensively. The presentmore » paper describes the toxicity, at different salinities, of Na/sub 2/, CrO/sub 4/, (chromate) and 3,4-dichloroaniline (3,4-DCA) to a number of relatively small adult and larval crustaceans. Chromate was chosen as a model of a heavy metal since, although its toxicity may be relatively low, it may under certain circumstance have considerable environmental effects. Moreover, bichromate has been recommended as a standard in Daphnia tests. 3,4-dichloroaniline was chosen as a model of a chlorinated hydrocarbon, the handling of which does not need special precautions.« less

  17. Calculation of color difference and measurement of the spectrum of aerosol based on human visual system

    NASA Astrophysics Data System (ADS)

    Dai, Mengyan; Liu, Jianghai; Cui, Jianlin; Chen, Chunsheng; Jia, Peng

    2017-10-01

    In order to solve the problem of the quantitative test of spectrum and color of aerosol, the measurement method of spectrum of aerosol based on human visual system was proposed. The spectrum characteristics and color parameters of three different aerosols were tested, and the color differences were calculated according to the CIE1976-L*a*b* color difference formula. Three tested powders (No 1# No 2# and No 3# ) were dispersed in a plexglass box and turned into aerosol. The powder sample was released by an injector with different dosages in each experiment. The spectrum and color of aerosol were measured by the PRO 6500 Fiber Optic Spectrometer. The experimental results showed that the extinction performance of aerosol became stronger and stronger with the increase of concentration of aerosol. While the chromaticity value differences of aerosols in the experiment were so small, luminance was verified to be the main influence factor of human eye visual perception and contributed most in the three factors of the color difference calculation. The extinction effect of No 3# aerosol was the strongest of all and caused the biggest change of luminance and color difference which would arouse the strongest human visual perception. According to the sensation level of chromatic color by Chinese, recognition color difference would be produced when the dosage of No 1# powder was more than 0.10 gram, the dosage of No 2# powder was more than 0.15 gram, and the dosage of No 3# powder was more than 0.05 gram.

  18. Possible influences on color constancy by motion of color targets and by attention-controlled gaze.

    PubMed

    Wan, Lifang; Shinomori, Keizo

    2018-04-01

    We investigated the influence of motion on color constancy using a chromatic stimulus presented in various conditions (static, motion, and rotation). Attention to the stimulus and background was also controlled in different gaze modes, constant fixation of the stimulus, and random viewing of the stimulus. Color constancy was examined in six young observers using a haploscopic view of a computer monitor. The target and background were illuminated in simulation by red, green, blue, and yellow, shifted from daylight (D65) by specific color differences along L - M or S - (L + M) axes on the equiluminance plane. The standard pattern (under D65) and test pattern (under the color illuminant) of a 5-deg square were presented side by side, consisting of 1.2-deg square targets with one of 12 colors at each center, surrounded by 230 background ellipses consisting of eight other colors. The central color targets in both patterns flipped between top and bottom locations at the rate of 3 deg/s in the motion condition. The results indicated an average reduction of color constancy over the 12 test colors by motion. The random viewing parameter indicated better color constancy by more attention to the background, although the difference was not significant. Color constancy of the four color illuminations was better to worse in green, red, yellow, and blue, respectively. The reduction of color constancy by motion could be explained by less contribution of the illumination estimation effect on color constancy. In the motion with constant fixation condition, the retina strongly adapted to the mean chromaticity of the background. However, motion resulted in less attention to the color of the background, causing a weaker effect of the illumination estimation. Conversely, in the static state with a random viewing condition, more attention to the background colors caused a stronger illumination estimation effect, and color constancy was improved overall.

  19. Kinetic and thermodynamic studies of AISI 4130 steel alloy corrosion in ethylene glycol-water mixture in presence of inhibitors

    NASA Astrophysics Data System (ADS)

    Khomami, M. Niknejad; Danaee, I.; Attar, A. A.; Peykari, M.

    2013-05-01

    The electrochemical behavior of steel alloy in ethylene glycol-water mixture was investigated by electrochemical methods. The results obtained showed that corrosion rate was decreased with increasing ethylene glycol concentration. The effect of inorganic inhibitors including NO3 -, NO2 -, Cr2O7 2- and CrO4 2- were studied using electrochemical techniques where the highest inhibition efficiency was obtained for CrO4 2-. In the presence of chromate the inhibitor efficiency increased with its concentration. The inhibiting effect of the chromate was explained on the basis of the competitive adsorption between the inorganic anions and the aggressive Cl- ions, and the adsorption isotherm basically obeys the Langmuir adsorption isotherm. Thermodynamic parameters for steel corrosion and inhibitor adsorption were determined and reveal that the adsorption process is spontaneous. Also, a phenomenon of both physical and chemical adsorption is proposed.

  20. Robust Foregrounds Removal for 21-cm Experiments

    NASA Astrophysics Data System (ADS)

    Mertens, F.; Ghosh, A.; Koopmans, L. V. E.

    2018-05-01

    Direct detection of the Epoch of Reionization via the redshifted 21-cm line will have unprecedented implications on the study of structure formation in the early Universe. To fulfill this promise current and future 21-cm experiments will need to detect the weak 21-cm signal over foregrounds several order of magnitude greater. This requires accurate modeling of the galactic and extragalactic emission and of its contaminants due to instrument chromaticity, ionosphere and imperfect calibration. To solve for this complex modeling, we propose a new method based on Gaussian Process Regression (GPR) which is able to cleanly separate the cosmological signal from most of the foregrounds contaminants. We also propose a new imaging method based on a maximum likelihood framework which solves for the interferometric equation directly on the sphere. Using this method, chromatic effects causing the so-called ``wedge'' are effectively eliminated (i.e. deconvolved) in the cylindrical (k⊥, k∥) power spectrum.

  1. Fokker-Planck analysis of transverse collective instabilities in electron storage rings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindberg, Ryan R.

    We analyze single bunch transverse instabilities due to wakefields using a Fokker-Planck model. We first expand on the work of T. Suzuki, Part. Accel. 12, 237 (1982) to derive the theoretical model including chromaticity, both dipolar and quadrupolar transverse wakefields, and the effects of damping and diffusion due to the synchrotron radiation. We reduce the problem to a linear matrix equation, whose eigenvalues and eigenvectors determine the collective stability of the beam. We then show that various predictions of the theory agree quite well with results from particle tracking simulations, including the threshold current for transverse instability and the profilemore » of the unstable mode. In particular, we find that predicting collective stability for high energy electron beams at moderate to large values of chromaticity requires the full Fokker-Planck analysis to properly account for the effects of damping and diffusion due to synchrotron radiation.« less

  2. Environmental exposure to chromium compounds in the valley of León, México.

    PubMed Central

    Armienta-Hernández, M A; Rodríguez-Castillo, R

    1995-01-01

    The effects on the environment and health of the operation of a chromate compounds factory and tanneries in the León valley in central México are discussed. Sampling and analysis of chromium were performed in water, soil, and human urine. Groundwater has been polluted in an area of about 5 km2 by the leaching of a solid factory waste, which results in concentrations up to 50 mg/l of hexavalent chromium. The plume shape and extension appear to be controlled by the prevailing well extraction regime. Total chromium was detected in the soil around the factory as a result of both aerial transport and deposition of dust produced in the chromate process and irrigation with tannery-contaminated water. Analysis of the impact of chromium in air and water on populations with various degrees of exposure revealed that highly harmful health effects were not observed. PMID:7621799

  3. Effects of shape, size, and chromaticity of stimuli on estimated size in normally sighted, severely myopic, and visually impaired students.

    PubMed

    Huang, Kuo-Chen; Wang, Hsiu-Feng; Chen, Chun-Ching

    2010-06-01

    Effects of shape, size, and chromaticity of stimuli on participants' errors when estimating the size of simultaneously presented standard and comparison stimuli were examined. 48 Taiwanese college students ages 20 to 24 years old (M = 22.3, SD = 1.3) participated. Analysis showed that the error for estimated size was significantly greater for those in the low-vision group than for those in the normal-vision and severe-myopia groups. The errors were significantly greater with green and blue stimuli than with red stimuli. Circular stimuli produced smaller mean errors than did square stimuli. The actual size of the standard stimulus significantly affected the error for estimated size. Errors for estimations using smaller sizes were significantly higher than when the sizes were larger. Implications of the results for graphics-based interface design, particularly when taking account of visually impaired users, are discussed.

  4. Methods and optical fibers that decrease pulse degradation resulting from random chromatic dispersion

    DOEpatents

    Chertkov, Michael; Gabitov, Ildar

    2004-03-02

    The present invention provides methods and optical fibers for periodically pinning an actual (random) accumulated chromatic dispersion of an optical fiber to a predicted accumulated dispersion of the fiber through relatively simple modifications of fiber-optic manufacturing methods or retrofitting of existing fibers. If the pinning occurs with sufficient frequency (at a distance less than or are equal to a correlation scale), pulse degradation resulting from random chromatic dispersion is minimized. Alternatively, pinning may occur quasi-periodically, i.e., the pinning distance is distributed between approximately zero and approximately two to three times the correlation scale.

  5. Exploiting chromatic aberration to spectrally encode depth in reflectance confocal microscopy

    NASA Astrophysics Data System (ADS)

    Carrasco-Zevallos, Oscar; Shelton, Ryan L.; Olsovsky, Cory; Saldua, Meagan; Applegate, Brian E.; Maitland, Kristen C.

    2011-06-01

    We present chromatic confocal microscopy as a technique to axially scan the sample by spectrally encoding depth information to avoid mechanical scanning of the lens or sample. We have achieved an 800 μm focal shift over a range of 680-1080 nm using a hyperchromat lens as the imaging lens. A more complex system that incorporates a water immersion objective to improve axial resolution was built and tested. We determined that increasing objective magnification decreases chromatic shift while improving axial resolution. Furthermore, collimating after the hyperchromat at longer wavelengths yields an increase in focal shift.

  6. Spatial and temporal aspects of chromatic adaptation and their functional significance for colour constancy.

    PubMed

    Werner, Annette

    2014-11-01

    Illumination in natural scenes changes at multiple temporal and spatial scales: slow changes in global illumination occur in the course of a day, and we encounter fast and localised illumination changes when visually exploring the non-uniform light field of three-dimensional scenes; in addition, very long-term chromatic variations may come from the environment, like for example seasonal changes. In this context, I consider the temporal and spatial properties of chromatic adaptation and discuss their functional significance for colour constancy in three-dimensional scenes. A process of fast spatial tuning in chromatic adaptation is proposed as a possible sensory mechanism for linking colour constancy to the spatial structure of a scene. The observed middlewavelength selectivity of this process is particularly suitable for adaptation to the mean chromaticity and the compensation of interreflections in natural scenes. Two types of sensory colour constancy are distinguished, based on the functional differences of their temporal and spatial scales: a slow type, operating at a global scale for the compensation of the ambient illumination; and a fast colour constancy, which is locally restricted and well suited to compensate region-specific variations in the light field of three dimensional scenes. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fruchter, Jonathan S.

    In Situ Treatment of Chromate Contaminated Groundwater Jonathan S. Fruchter Pacific Northwest National Laboratory Abstract of paper published in Environmental Science and Technology, 2002 Although not as common as solvent or fuel products contamination, chromate (chromium (VI)) contamination of groundwater is relatively widespread. Chromate has a variety of industrial uses, including chrome plating, steel making, and use as a corrosion inhibitor, wood preservative, well-drilling fluid additive, biocide, and as a pigment in paints and primers. EPA has estimated that as many as 1300 sites in the United States may have groundwater contaminated with chromate. The paper discusses a number ofmore » approaches to in situ treatment of chromate contamination in groundwater aquifers. The approaches include various types of chemical treatments, biological treatments and natural attenuation. The strengths and weaknesses of each method are discussed and compared. Field examples of two types of chemical treatment, in situ redox manipulation and chemically enhanced pump and treat are presented. It is concluded that in situ methods show promise, but can be difficult to implement due to site-specific conditions and limited long-term experience with these methods. As more performance and cost data are acquired for the demonstrations that are ongoing, and continuing research increases our understanding of subsurface processes, in situ treatment methods for chromium (VI) contamination in groundwater should gain wider acceptance.« less

  8. Evaluation of layered zinc hydroxide nitrate and zinc/nickel double hydroxide salts in the removal of chromate ions from solutions

    NASA Astrophysics Data System (ADS)

    de Oliveira, Henrique Bortolaz; Wypych, Fernando

    2016-11-01

    Layered zinc hydroxide nitrate (ZnHN) and Zn/Ni layered double hydroxide salts were synthesized and used to remove chromate ions from solutions at pH 8.0. The materials were characterized by many instrumental techniques before and after chromate ion removal. ZnHN decomposed after contact with the chromate solution, whereas the layered structure of Zn/Ni hydroxide nitrate (Zn/NiHN) and Zn/Ni hydroxide acetate (Zn/NiHA) remained their layers intact after the topotactic anionic exchange reaction, only changing the basal distances. ZnHN, Zn/NiHN, and Zn/NiHA removed 210.1, 144.8, and 170.1 mg of CrO42-/g of material, respectively. Although the removal values obtained for Zn/NiHN and Zn/NiHA were smaller than the values predicted for the ideal formulas of the solids (194.3 and 192.4 mg of CrO42-/g of material, respectively), the measured capacities were higher than the values achieved with many materials reported in the literature. Kinetic experiments showed the removal reaction was fast. To facilitate the solid/liquid separation process after chromium removal, Zn/Ni layered double hydroxide salts with magnetic supports were also synthesized, and their ability to remove chromate was evaluated.

  9. Corrosion Resistance Characterization of Coating Systems Used to Protect Aluminum Alloys Using Electrochemical Impedance Spectroscopy and Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Gambina, Federico

    In this study, the corrosion protection provided by of a number of chromate and chromate-free coatings systems was characterized in detail. High-solids SrCrO4-pigmented epoxy primers applied to 2024 and 7075 substrates were subject to salt spray exposure testing for 30 days. Samples were removed periodically and an electrochemical impedance measurement (EIS) was made. Although none of the coatings tested showed visual evidence of corrosion, the total impedance of the samples decreased by as much as two orders of magnitude. An analysis of capacitance showed that the primer coatings rapidly took up water from the exposure environment, but the coating-metal remained passive despite the fact that it was wet. These results support the idea that chromate coatings protect by creating a chromate-rich electrolyte within the coating that is passivating to the underlying metal substrate. They also suggest that indications of metal substrate passivity found in the low-frequency capacitive reactance of the impedance spectra are a better indicator of corrosion protection than the total impedance. The low-frequency capacitive reactance from EIS measurements is also good at assessing the protectiveness of chromate-free coatings systems. Fifteen different coatings systems comprising high-solids, chromate-free primers and chromate-free conversion coatings were applied to 2024 and 7075 substrates. These coatings were subject to salt spray exposure and EIS measurements. All coatings were inferior to coating systems containing chromate, but changes in the capacitive reactance measured in EIS was shown to anticipate visual indications of coating failure. A predictive model based on neural networks was trained to recognize the pattern in the capacitive reactance in impedance spectra measured after 48 hours of exposure and make an estimate of remaining coating life. A sensitivity analysis was performed to prune the impedance inputs. As a result of this analysis, a very simple but highly predictive model was constructed that used low-frequency phase angle information extracted directly from EIS measurements to predict time to failure in salt spray up to 30 days of exposure. The exposure and EIS characterization of the chromate-free coatings systems enabled a ranking of the coatings systems in terms of corrosion protection provided. Coating systems were ranked according to several different methods described in the literature. Among the coatings evaluated, Deft 02GN084, a high solids, solvent-borne and Pr-containing primer coating showed best protection when used in conjunction with a number of different conversion coatings and surface pretreatments. Several different trivalent chromium conversion coatings and pretreatment were used. This general type of conversion coating appeared to provide better corrosion protection than other pretreatments whose functions were primarily surface cleaning or adhesion promotion.

  10. Artwork visualization using a solid-state lighting engine with controlled photochemical safety.

    PubMed

    Tuzikas, Arūnas; Žukauskas, Artūras; Vaicekauksas, Rimantas; Petrulis, Andrius; Vitta, Pranciškus; Shur, Michael

    2014-07-14

    A concept of a solid-state lighting engine for artwork-specific illumination with controlled photochemical safety is introduced. The engine is based on a tetrachromatic cluster of colored light-emitting diodes wirelessly controlled via an external smart device. By using an instantaneous dimming functionality, the driving software allows for maintaining the damage irradiance relevant to a particular type of photosensitive artwork material at a constant value, while varying the chromaticity and color rendition properties of the generated light. The effect of the constant damage irradiance on the visual impression from artworks is demonstrated for the lighting engine operating in three modes, such as selecting color temperature, tuning color saturating ability, and shifting chromaticity outside white light locus, respectively.

  11. Simultaneous chromatic dispersion, polarization-mode-dispersion and OSNR monitoring at 40Gbit/s.

    PubMed

    Baker-Meflah, Lamia; Thomsen, Benn; Mitchell, John; Bayvel, Polina

    2008-09-29

    A novel method for independent and simultaneous monitoring of chromatic dispersion (CD), first-order PMD and OSNR in 40Gbit/s systems is proposed and demonstrated. This is performed using in-band tone monitoring of 5GHz, optically down-converted to a low intermediate-frequency (IF) of 10kHz. The measurement provides a large monitoring range with good accuracies for CD (4742+/-100ps/nm), differential group delay (DGD) (200+/-4ps) and OSNR (23+/-1dB), independently of the bit-rate. In addition, the use of electro-absorption modulators (EAM) for the simultaneous down-conversion of all channels and the use of low-speed detectors makes it cost effective for multi-channel operation.

  12. Design of a 6 TeV muon collider

    DOE PAGES

    Wang, M-H.; Nosochkov, Y.; Cai, Y.; ...

    2016-09-09

    Here, a preliminary design of a muon collider ring with the center of mass (CM) energy of 6 TeV is presented. The ring circumference is 6.3 km, and themore » $$\\beta$$ functions at collision point are 1 cm in each plane. The ring linear optics, the non-linear chromaticity compensation in the Interaction Region (IR), and the additional non-linear orthogonal correcting knobs are described. Magnet specifications are based on the maximum pole-tip field of 20T in dipoles and 15T in quadrupoles. Careful compensation of the non-linear chromatic and amplitude dependent effects provide a sufficiently large dynamic aperture for the momentum range of up to $$\\pm$$0.5% without considering magnet errors.« less

  13. KINETICS OF SOLUBLE CHROMIUM REMOVAL FROM CONTAMINATED WATER BY ZEROVALENT IRON MEDIA: CORROSION INHIBITION AND PASSIVE OXIDE EFFECTS. (R825223)

    EPA Science Inventory

    Permeable reactive barriers containing zerovalent iron are being increasingly
    employed for in situ remediation of groundwater contaminated with redox active
    metals and chlorinated organic compounds. This research investigated the effect
    of chromate concentration on...

  14. EVALUATION OF THE EFFECTIVENESS OF COATINGS IN REDUCING DISLODGEABLE ARSENIC, CHROMIUM, AND COPPER FROM CCA-TREATED WOOD

    EPA Science Inventory

    This is a 2 year study designed to evaluate the effectiveness of a variety of deck sealants in reducing or eliminating potential exposure to arsenic, chromium, and copper from chromated copper arsenate-treated wood used in residential settings, like decks and playsets.

  15. Color vision in ADHD: part 2--does attention influence color perception?

    PubMed

    Kim, Soyeon; Al-Haj, Mohamed; Fuller, Stuart; Chen, Samantha; Jain, Umesh; Carrasco, Marisa; Tannock, Rosemary

    2014-10-24

    To investigate the impact of exogenous covert attention on chromatic (blue and red) and achromatic visual perception in adults with and without Attention Deficit Hyperactivity Disorder (ADHD). Exogenous covert attention, which is a transient, automatic, stimulus-driven form of attention, is a key mechanism for selecting relevant information in visual arrays. 30 adults diagnosed with ADHD and 30 healthy adults, matched on age and gender, performed a psychophysical task designed to measure the effects of exogenous covert attention on perceived color saturation (blue, red) and contrast sensitivity. The effects of exogenous covert attention on perceived blue and red saturation levels and contrast sensitivity were similar in both groups, with no differences between males and females. Specifically, exogenous covert attention enhanced the perception of blue saturation and contrast sensitivity, but it had no effect on the perception of red saturation. The findings suggest that exogenous covert attention is intact in adults with ADHD and does not account for the observed impairments in the perception of chromatic (blue and red) saturation.

  16. Birds see the true colours of fruits to live off the fat of the land

    PubMed Central

    Schaefer, H. Martin; Valido, Alfredo; Jordano, Pedro

    2014-01-01

    Communication is a characteristic of life, but its reliability and basic definition are hotly debated. Theory predicts that trade among mutualists requires high reliability. Here, we show that moderate reliability already allows mutualists to optimize their rewards. The colours of Mediterranean fleshy-fruits indicate lipid rewards (but not other nutrients) to avian seed dispersers on regional and local scales. On the regional scale, fruits with high lipid content were significantly darker and less chromatic than congeners with lower lipid content. On the local scale, two warbler species (Sylvia atricapilla and Sylvia borin) selected fruit colours that were less chromatic, and thereby maximized their intake of lipids—a critical resource during migration and wintering. Crucially, birds were able to maximize lipid rewards with moderate reliability from visual fruit colours (r2 = 0.44–0.60). We suggest that mutualisms require only that any association between the quality and sensory aspects of signallers is learned through multiple, repeated interactions. Because these conditions are often fulfilled, also in social communication systems, we contend that selection on reliability is less intense than hitherto assumed. This may contribute to explaining the extraordinary diversity of signals, including that of plant reproductive displays. PMID:24403330

  17. High performance flexible top-emitting warm-white organic light-emitting devices and chromaticity shift mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Hongying; Deng, Lingling; Chen, Shufen, E-mail: iamsfchen@njupt.edu.cn, E-mail: wei-huang@njupt.edu.cn

    2014-04-15

    Flexible warm-white top-emitting organic light-emitting devices (TEOLEDs) are fabricated onto PET substrates with a simple semi-transparent cathode Sm/Ag and two-color phosphors respectively doped into a single host material TCTA. By adjusting the relative position of the orange-red EML sandwiched between the blue emitting layers, the optimized device exhibits the highest power/current efficiency of 8.07 lm/W and near 13 cd/A, with a correlated color temperature (CCT) of 4105 K and a color rendering index (CRI) of 70. In addition, a moderate chromaticity variation of (-0.025, +0.008) around warm white illumination coordinates (0.45, 0.44) is obtained over a large luminance range ofmore » 1000 to 10000 cd/m{sup 2}. The emission mechanism is discussed via delta-doping method and single-carrier device, which is summarized that the carrier trapping, the exciton quenching, the mobility change and the recombination zone alteration are negative to color stability while the energy transfer process and the blue/red/blue sandwiched structure are contributed to the color stability in our flexible white TEOLEDs.« less

  18. Functional organization for musical consonance and tonal pitch hierarchy in human auditory cortex.

    PubMed

    Bidelman, Gavin M; Grall, Jeremy

    2014-11-01

    Pitch relationships in music are characterized by their degree of consonance, a hierarchical perceptual quality that distinguishes how pleasant musical chords/intervals sound to the ear. The origins of consonance have been debated since the ancient Greeks. To elucidate the neurobiological mechanisms underlying these musical fundamentals, we recorded neuroelectric brain activity while participants listened passively to various chromatic musical intervals (simultaneously sounding pitches) varying in their perceptual pleasantness (i.e., consonance/dissonance). Dichotic presentation eliminated acoustic and peripheral contributions that often confound explanations of consonance. We found that neural representations for pitch in early human auditory cortex code perceptual features of musical consonance and follow a hierarchical organization according to music-theoretic principles. These neural correlates emerge pre-attentively within ~ 150 ms after the onset of pitch, are segregated topographically in superior temporal gyrus with a rightward hemispheric bias, and closely mirror listeners' behavioral valence preferences for the chromatic tone combinations inherent to music. A perceptual-based organization implies that parallel to the phonetic code for speech, elements of music are mapped within early cerebral structures according to higher-order, perceptual principles and the rules of Western harmony rather than simple acoustic attributes. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Effects of Ocular Optics on Perceived Visual Direction and Depth

    NASA Astrophysics Data System (ADS)

    Ye, Ming

    Most studies of human retinal image quality have specifically addressed the issues of image contrast, few have examined the problem of image location. However, one of the most impressive properties of human vision involves the location of objects. We are able to identify object location with great accuracy (less than 5 arcsec). The sensitivity we exhibit for image location indicates that any optical errors, such as refractive error, ocular aberrations, pupil decentration, etc., may have noticeable effects on perceived visual direction and distance of objects. The most easily observed effects of these optical factors is a binocular depth illusion called chromostereopsis in which equidistance colored objects appear to lie at the different distances. This dissertation covers a series of theoretical and experimental studies that examined the effects of ocular optics on perceived monocular visual direction and binocular chromostereopsis. Theoretical studies included development of an adequate eye model for predicting chromatic aberration, a major ocular aberration, using geometric optics. Also, a wave optical analysis is used to model the effects of defocus, optical aberrations, Stiles-Crawford effect (SCE) and pupil location on retinal image profiles. Experimental studies used psychophysical methods such as monocular vernier alignment tests, binocular stereoscopic tests, etc. This dissertation concludes: (1) With a decentered large pupil, the SCE reduces defocused image shifts compare to an eye without the SCE. (2) The blurred image location can be predicted by the centroid of the image profile. (3) Chromostereopsis with small pupils can be precisely accounted for by the interocular difference in monocular transverse chromatic aberration. (4) The SCE also plays an important role in the effect of pupil size on chromostereopsis. The reduction of chromostereopsis with large pupils can be accurately predicted by the interocular difference in monocular chromatic diplopia which is also reduced with large pupils. This supports the hypothesis that the effect of pupil size on chromostereopsis is due to monocular mechanisms.

  20. Cone photoreceptor sensitivities and unique hue chromatic responses: correlation and causation imply the physiological basis of unique hues.

    PubMed

    Pridmore, Ralph W

    2013-01-01

    This paper relates major functions at the start and end of the color vision process. The process starts with three cone photoreceptors transducing light into electrical responses. Cone sensitivities were once expected to be Red Green Blue color matching functions (to mix colors) but microspectrometry proved otherwise: they instead peak in yellowish, greenish, and blueish hues. These physiological functions are an enigma, unmatched with any set of psychophysical (behavioral) functions. The end-result of the visual process is color sensation, whose essential percepts are unique (or pure) hues red, yellow, green, blue. Unique hues cannot be described by other hues, but can describe all other hues, e.g., that hue is reddish-blue. They are carried by four opponent chromatic response curves but the literature does not specify whether each curve represents a range of hues or only one hue (a unique) over its wavelength range. Here the latter is demonstrated, confirming that opponent chromatic responses define, and may be termed, unique hue chromatic responses. These psychophysical functions also are an enigma, unmatched with any physiological functions or basis. Here both enigmas are solved by demonstrating the three cone sensitivity curves and the three spectral chromatic response curves are almost identical sets (Pearson correlation coefficients r from 0.95-1.0) in peak wavelengths, curve shapes, math functions, and curve crossover wavelengths, though previously unrecognized due to presentation of curves in different formats, e.g., log, linear. (Red chromatic response curve is largely nonspectral and thus derives from two cones.) Close correlation combined with deterministic causation implies cones are the physiological basis of unique hues. This match of three physiological and three psychophysical functions is unique in color vision.

  1. Callitriche cophocarpa (water starwort) proteome under chromate stress: evidence for induction of a quinone reductase.

    PubMed

    Kaszycki, Paweł; Dubicka-Lisowska, Aleksandra; Augustynowicz, Joanna; Piwowarczyk, Barbara; Wesołowski, Wojciech

    2018-03-01

    Chromate-induced physiological stress in a water-submerged macrophyte Callitriche cophocarpa Sendtn. (water starwort) was tested at the proteomic level. The oxidative stress status of the plant treated with 1 mM Cr(VI) for 3 days revealed stimulation of peroxidases whereas catalase and superoxide dismutase activities were similar to the control levels. Employing two-dimensional electrophoresis, comparative proteomics enabled to detect five differentiating proteins subjected to identification with mass spectrometry followed by an NCBI database search. Cr(VI) incubation led to induction of light harvesting chlorophyll a/b binding protein with a concomitant decrease of accumulation of ribulose bisphosphate carboxylase (RuBisCO). The main finding was, however, the identification of an NAD(P)H-dependent dehydrogenase FQR1, detectable only in Cr(VI)-treated plants. The FQR1 flavoenzyme is known to be responsive to oxidative stress and to act as a detoxification protein by protecting the cells against oxidative damage. It exhibits the in vitro quinone reductase activity and is capable of catalyzing two-electron transfer from NAD(P)H to several substrates, presumably including Cr(VI). The enhanced accumulation of FQR1 was chromate-specific since other stressful conditions, such as salt, temperature, and oxidative stresses, all failed to induce the protein. Zymographic analysis of chromate-treated Callitriche shoots showed a novel enzymatic protein band whose activity was attributed to the newly identified enzyme. We suggest that Cr(VI) phytoremediation with C. cophocarpa can be promoted by chromate reductase activity produced by the induced quinone oxidoreductase which might take part in Cr(VI) → Cr(III) bioreduction process and thus enable the plant to cope with the chromate-generated oxidative stress.

  2. Cone Photoreceptor Sensitivities and Unique Hue Chromatic Responses: Correlation and Causation Imply the Physiological Basis of Unique Hues

    PubMed Central

    Pridmore, Ralph W.

    2013-01-01

    This paper relates major functions at the start and end of the color vision process. The process starts with three cone photoreceptors transducing light into electrical responses. Cone sensitivities were once expected to be Red Green Blue color matching functions (to mix colors) but microspectrometry proved otherwise: they instead peak in yellowish, greenish, and blueish hues. These physiological functions are an enigma, unmatched with any set of psychophysical (behavioral) functions. The end-result of the visual process is color sensation, whose essential percepts are unique (or pure) hues red, yellow, green, blue. Unique hues cannot be described by other hues, but can describe all other hues, e.g., that hue is reddish-blue. They are carried by four opponent chromatic response curves but the literature does not specify whether each curve represents a range of hues or only one hue (a unique) over its wavelength range. Here the latter is demonstrated, confirming that opponent chromatic responses define, and may be termed, unique hue chromatic responses. These psychophysical functions also are an enigma, unmatched with any physiological functions or basis. Here both enigmas are solved by demonstrating the three cone sensitivity curves and the three spectral chromatic response curves are almost identical sets (Pearson correlation coefficients r from 0.95–1.0) in peak wavelengths, curve shapes, math functions, and curve crossover wavelengths, though previously unrecognized due to presentation of curves in different formats, e.g., log, linear. (Red chromatic response curve is largely nonspectral and thus derives from two cones.) Close correlation combined with deterministic causation implies cones are the physiological basis of unique hues. This match of three physiological and three psychophysical functions is unique in color vision. PMID:24204755

  3. Impact of colour in the assessment of potential visual acuity in patients with age-related macular degeneration.

    PubMed

    Dorrepaal, Stephen J; Markowitz, Samuel N

    2013-06-01

    To compare chromatic and achromatic potential visual acuity (PVA) in patients with bilateral low vision caused by age-related macular degeneration (AMD). Prospective, nonrandomized, observational case series. Fifty-five patients, representing a consecutive series of patients all presenting with bilateral AMD. Best-corrected visual acuity of each eye was measured using an Early Treatment in Diabetic Retinopathy Study (ETDRS) chart with appropriate near correction. Included were cases with visual acuity of 0.4 logMAR (20/50) or worse in both eyes. Achromatic and chromatic PVA were measured in each eye using white on black and red on yellow flooding E charts at 50 cm in controlled lighting conditions. One hundred and seven eyes from 55 patients were included in the analysis. Mean achromatic and chromatic PVA were 0.69 ± 0.26 and 0.65 ± 0.22 logMAR, respectively. Overall, patients had a significantly higher chromatic than achromatic PVA, with a median difference of 0.1 logMAR (p<0.05). Patients with ETDRS visual acuity worse than 0.9 logMAR also had a significantly higher chromatic than achromatic PVA, with a median difference of 0.1 logMAR (p<0.05). Patients with ETDRS visual acuity between 0.4 and 0.9 logMAR had a trend toward a higher chromatic than achromatic visual acuity that was not significant, with a median difference of 0.1 logMAR (p = 0.8539). Patients with low vision caused by AMD can discern smaller targets when a red on yellow colour scheme is used than when using achromatic white on black charts. Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  4. Effects of Industrial Cashew Nut Processing on Anacardic Acid Content and Allergen Recognition by IgE

    USDA-ARS?s Scientific Manuscript database

    Cashew nuts are consumed worldwide and are in high demand, but they can also cause food allergy in some individuals. The present study aimed to assess the effect(s) of industrial processing on anacardic acids and allergens present in cashew nuts. Sample analyses were performed using liquid chromat...

  5. Chromatic spatial contrast sensitivity estimated by visual evoked cortical potential and psychophysics

    PubMed Central

    Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L.

    2013-01-01

    The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus. PMID:23369980

  6. Hexavalent chromium induces chromosome instability in human urothelial cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wise, Sandra S.; Holmes, Amie L.; Department of Radiation Oncology, Dana Farber Cancer Institute, 450 Brookline Ave., Boston, MA 02215

    Numerous metals are well-known human bladder carcinogens. Despite the significant occupational and public health concern of metals and bladder cancer, the carcinogenic mechanisms remain largely unknown. Chromium, in particular, is a metal of concern as incidences of bladder cancer have been found elevated in chromate workers, and there is an increasing concern for patients with metal hip implants. However, the impact of hexavalent chromium (Cr(VI)) on bladder cells has not been studied. We compared chromate toxicity in two bladder cell lines; primary human urothelial cells and hTERT-immortalized human urothelial cells. Cr(VI) induced a concentration- and time-dependent increase in chromosome damagemore » in both cell lines, with the hTERT-immortalized cells exhibiting more chromosome damage than the primary cells. Chronic exposure to Cr(VI) also induced a concentration-dependent increase in aneuploid metaphases in both cell lines which was not observed after a 24 h exposure. Aneuploidy induction was higher in the hTERT-immortalized cells. When we correct for uptake, Cr(VI) induces a similar amount of chromosome damage and aneuploidy suggesting that the differences in Cr(VI) sensitivity between the two cells lines were due to differences in uptake. The increase in chromosome instability after chronic chromate treatment suggests this may be a mechanism for chromate-induced bladder cancer, specifically, and may be a mechanism for metal-induced bladder cancer, in general. - Highlights: • Hexavalent chromium is genotoxic to human urothelial cells. • Hexavalent chromium induces aneuploidy in human urothelial cells. • hTERT-immortalized human urothelial cells model the effects seen in primary urothelial cells. • Hexavalent chromium has a strong likelihood of being carcinogenic for bladder tissue.« less

  7. Colour also matters for nocturnal birds: owlet bill coloration advertises quality and influences parental feeding behaviour in little owls.

    PubMed

    Avilés, J M; Parejo, D

    2013-10-01

    Chromatic signals of offspring quality have been shown to play a role in parent-offspring communication in diurnal birds, but are assumed to be useless in dim light conditions because colour-based discrimination probably requires more light. A major ecological and evolutionary conundrum in this scenario is why the nestlings of some nocturnal owls display colourful beaks. Here, we test the hypothesis that yellow bill coloration of owlets of the nocturnal little owl Athene noctua may function as a chromatic signal revealing to parents aspects of quality of their offspring. In a first step, we examined physical variation in bill coloration and its covariation with owlet quality. Secondly, we studied parental provisioning in relation to an experimental manipulation of bill coloration of owlets. Bills of owlets showed higher within-nest variation in yellow-red chroma than in brightness. Plasma carotenoid concentration and nestling immunological status were not associated with chromatic or achromatic features of the bill. Interestingly, however, heavier owlets displayed more yellow bills than lighter ones. The effect of bill coloration on parental favouritism changed with brood size. Parents holding large broods preferentially fed owlets with enhanced over reduced yellow bill coloration, whereas those with small broods did not significantly bias feeding in relation to owlet bill coloration. Our results, based on integration of objective spectrophotometric assessment of colour and experimental procedures, confirm that parent little owls use bill coloration to reveal information on owlet body mass to adjust their feeding strategies, thus highlighting the importance of considering potential chromatic signals for a full comprehension of parent-offspring communication processes in nocturnal bird species.

  8. Estimation of chromatic errors from broadband images for high contrast imaging: sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Sirbu, Dan; Belikov, Ruslan

    2016-01-01

    Many concepts have been proposed to enable direct imaging of planets around nearby stars, and which would enable spectroscopic observations of their atmospheric observations and the potential discovery of biomarkers. The main technical challenge associated with direct imaging of exoplanets is to effectively control both the diffraction and scattered light from the star so that the dim planetary companion can be seen. Usage of an internal coronagraph with an adaptive optical system for wavefront correction is one of the most mature methods and is being developed as an instrument addition to the WFIRST-AFTA space mission. In addition, such instruments as GPI and SPHERE are already being used on the ground and are yielding spectra of giant planets. For the deformable mirror (DM) to recover a dark hole region with sufficiently high contrast in the image plane, mid-spatial frequency wavefront errors must be estimated. To date, most broadband lab demonstrations use narrowband filters to obtain an estimate of the the chromaticity of the wavefront error and this can result in usage of a large percentage of the total integration time. Previously, we have proposed a method to estimate the chromaticity of wavefront errors using only broadband images; we have demonstrated that under idealized conditions wavefront errors can be estimated from images composed of discrete wavelengths. This is achieved by using DM probes with sufficient spatially-localized chromatic diversity. Here we report on the results of a study of the performance of this method with respect to realistic broadband images including noise. Additionally, we study optimal probe patterns that enable reduction of the number of probes used and compare the integration time with narrowband and IFS estimation methods.

  9. Sudden acquired retinal degeneration syndrome in western Canada: 93 cases.

    PubMed

    Leis, Marina L; Lucyshyn, Danica; Bauer, Bianca S; Grahn, Bruce H; Sandmeyer, Lynne S

    2017-11-01

    This study reviewed clinical data from dogs diagnosed with sudden acquired retinal degeneration syndrome (SARDS) in western Canada. Medical records from the Western College of Veterinary Medicine from 2002 to 2016 showed that 93 cases of SARDS were diagnosed based on presentation for sudden blindness and a bilaterally extinguished electroretinogram. The most common pure breeds were the miniature schnauzer, dachshund, and pug. The mean age at diagnosis was 8.1 years and males and females were equally affected. Most of the dogs were presented with normal non-chromatic, but abnormal chromatic pupillary light reflexes. The incidence of retinal degeneration as detected via ophthalmoscopy increased over time after SARDS diagnosis. Polyuria, polydipsia, polyphagia, weight gain, elevated liver enzyme values, isosthenuria, and proteinuria were common clinical and laboratory findings. Chromatic pupillary light reflex testing may be more valuable than non-chromatic pupillary light testing in detecting pupil response abnormalities in dogs with SARDS, although electroretinography remains the definitive diagnostic test.

  10. Sudden acquired retinal degeneration syndrome in western Canada: 93 cases

    PubMed Central

    Leis, Marina L.; Lucyshyn, Danica; Bauer, Bianca S.; Grahn, Bruce H.; Sandmeyer, Lynne S.

    2017-01-01

    This study reviewed clinical data from dogs diagnosed with sudden acquired retinal degeneration syndrome (SARDS) in western Canada. Medical records from the Western College of Veterinary Medicine from 2002 to 2016 showed that 93 cases of SARDS were diagnosed based on presentation for sudden blindness and a bilaterally extinguished electroretinogram. The most common pure breeds were the miniature schnauzer, dachshund, and pug. The mean age at diagnosis was 8.1 years and males and females were equally affected. Most of the dogs were presented with normal non-chromatic, but abnormal chromatic pupillary light reflexes. The incidence of retinal degeneration as detected via ophthalmoscopy increased over time after SARDS diagnosis. Polyuria, polydipsia, polyphagia, weight gain, elevated liver enzyme values, isosthenuria, and proteinuria were common clinical and laboratory findings. Chromatic pupillary light reflex testing may be more valuable than non-chromatic pupillary light testing in detecting pupil response abnormalities in dogs with SARDS, although electroretinography remains the definitive diagnostic test. PMID:29089658

  11. Obstructions to the realization of distance graphs with large chromatic numbers on spheres of small radii

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kupavskii, A B; Raigorodskii, A M

    2013-10-31

    We investigate in detail some properties of distance graphs constructed on the integer lattice. Such graphs find wide applications in problems of combinatorial geometry, in particular, such graphs were employed to answer Borsuk's question in the negative and to obtain exponential estimates for the chromatic number of the space. This work is devoted to the study of the number of cliques and the chromatic number of such graphs under certain conditions. Constructions of sequences of distance graphs are given, in which the graphs have unit length edges and contain a large number of triangles that lie on a sphere of radius 1/√3more » (which is the minimum possible). At the same time, the chromatic numbers of the graphs depend exponentially on their dimension. The results of this work strengthen and generalize some of the results obtained in a series of papers devoted to related issues. Bibliography: 29 titles.« less

  12. Amino-functionalized MCM-41 and MCM-48 for the removal of chromate and arsenate.

    PubMed

    Benhamou, A; Basly, J P; Baudu, M; Derriche, Z; Hamacha, R

    2013-08-15

    The aim of the present work was to investigate the efficiency of three amino-functionalized (hexadecylamine, dodecylamine, and dimethyldodecylamine) mesoporous silicas (MCM-41 and MCM-48) toward the adsorption of arsenate and chromate. Hexadecylamine-functionalized materials were characterized; BET surface areas, pore volumes, and sizes decreased with the functionalization, whereas XRD patterns show that the hexagonal structure of MCM-41 and the cubic structure of MCM-48 were not modified. The zeta potential decreases with pH and the highest arsenate and chromate removal was observed at the lowest pHs. Adsorption of chromium and arsenate was significantly enhanced after functionalization and amino-functionalized MCM-41 adsorb larger amounts of arsenate when compared to expanded MCM-48 materials. Chromate sorption capacities increased with the chain length and the larger capacities were obtained with hexadecylamine-functionalized mesoporous silicas. Mesoporous silicas modified by dimethyldodecylamine exhibited the higher arsenate sorption capacities. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Study of chromatic adaptation using memory color matches, Part II: colored illuminants.

    PubMed

    Smet, Kevin A G; Zhai, Qiyan; Luo, Ming R; Hanselaer, Peter

    2017-04-03

    In a previous paper, 12 corresponding color data sets were derived for 4 neutral illuminants using the long-term memory colours of five familiar objects. The data were used to test several linear (one-step and two-step von Kries, RLAB) and nonlinear (Hunt and Nayatani) chromatic adaptation transforms (CAT). This paper extends that study to a total of 156 corresponding color sets by including 9 more colored illuminants: 2 with low and 2 with high correlated color temperatures as well as 5 representing high chroma adaptive conditions. As in the previous study, a two-step von Kries transform whereby the degree of adaptation D is optimized to minimize the DEu'v' prediction errors outperformed all other tested models for both memory color and literature corresponding color sets, whereby prediction errors were lower for the memory color set. Most of the transforms tested, except the two- and one-step von Kries models with optimized D, showed large errors for corresponding color subsets that contained non-neutral adaptive conditions as all of them tended to overestimate the effective degree of adaptation in this study. An analysis of the impact of the sensor space primaries in which the adaptation is performed was found to have little impact compared to that of model choice. Finally, the effective degree of adaptation for the 13 illumination conditions (4 neutral + 9 colored) was successfully modelled using a bivariate Gaussian in a Macleod-Boyton like chromaticity diagram.

  14. THE IMPACT OF THE IONOSPHERE ON GROUND-BASED DETECTION OF THE GLOBAL EPOCH OF REIONIZATION SIGNAL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sokolowski, Marcin; Wayth, Randall B.; Tremblay, Steven E.

    2015-11-01

    The redshifted 21 cm line of neutral hydrogen (H i), potentially observable at low radio frequencies (∼50–200 MHz), is a promising probe of the physical conditions of the intergalactic medium during Cosmic Dawn and the Epoch of Reionization (EoR). The sky-averaged H i signal is expected to be extremely weak (∼100 mK) in comparison to the Galactic foreground emission (∼10{sup 4} K). Moreover, the sky-averaged spectra measured by ground-based instruments are affected by chromatic propagation effects (∼tens of kelvin) originating in the ionosphere. We analyze data collected with the upgraded Broadband Instrument for Global Hydrogen Reionization Signal system deployed atmore » the Murchison Radio-astronomy Observatory to assess the significance of ionospheric effects on the detection of the global EoR signal. The ionospheric effects identified in these data are, particularly during nighttime, dominated by absorption and emission. We measure some properties of the ionosphere, such as the electron temperature (T{sub e} ≈ 470 K at nighttime), magnitude, and variability of optical depth (τ{sub 100} {sub MHz} ≈ 0.01 and δτ ≈ 0.005 at nighttime). According to the results of a statistical test applied on a large data sample, very long integrations (∼100 hr collected over approximately 2 months) lead to increased signal-to-noise ratio even in the presence of ionospheric variability. This is further supported by the structure of the power spectrum of the sky temperature fluctuations, which has flicker noise characteristics at frequencies ≳10{sup −5} Hz, but becomes flat below ≈10{sup −5} Hz. Hence, we conclude that the stochastic error introduced by the chromatic ionospheric effects tends to zero in an average. Therefore, the ionospheric effects and fluctuations are not fundamental impediments preventing ground-based instruments from integrating down to the precision required by global EoR experiments, provided that the ionospheric contribution is properly accounted for in the data analysis.« less

  15. A color management system for multi-colored LED lighting

    NASA Astrophysics Data System (ADS)

    Chakrabarti, Maumita; Thorseth, Anders; Jepsen, Jørgen; Corell, Dennis D.; Dam-Hansen, Carsten

    2015-09-01

    A new color control system is described and implemented for a five-color LED light engine, covering a wide white gamut. The system combines a new way of using pre-calibrated lookup tables and a rule-based optimization of chromaticity distance from the Planckian locus with a calibrated color sensor. The color sensor monitors the chromaticity of the mixed light providing the correction factor for the current driver by using the generated lookup table. The long term stability and accuracy of the system will be experimentally investigated with target tolerance within a circle radius of 0.0013 in the uniform chromaticity diagram (CIE1976).

  16. ASSESSING CHILDREN'S EXPOSURES TO THE WOOD PRESERVATIVE CCA (CHROMATED COPPER ARSENATE) ON TREATED PLAYSETS AND DECKS

    EPA Science Inventory

    Concerns have been raised regarding the safety of young children contacting arsenic and chromium residues while playing on and around Chromated Copper Arsenate (CCA) treated wood playground structures and decks. Although CCA registrants voluntarily canceled treated wood for re...

  17. Lessons Learned in Technology Transition (Briefing Charts)

    DTIC Science & Technology

    2011-02-01

    recertification • Environmental regulations • Federal clean air act • OSHA and EPA requirements – Cadmium, hexavalent chromium, VOC reduction • ReaCH Copyright...Efforts • Non-Chromated Exterior System Non-chromated conversion coat and primer • Non- Chrome for other areas • Chemical topcoat reactivation Future

  18. Simultaneous speciation analysis of chromate, molybdate, tungstate and vanadate in welding fume alkaline extracts by HPLC-ICP-MS.

    PubMed

    Ščančar, Janez; Berlinger, Balázs; Thomassen, Yngvar; Milačič, Radmila

    2015-09-01

    A novel analytical procedure was developed for the simultaneous speciation analysis of chromate, molybdate, tungstate and vanadate by anion-exchange high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry (HPLC-ICP-MS). Linear gradient elution from 100% water to 100% 0.7 M NaCl was applied for chromatographic separation of metal species. In standard aqueous solution at neutral pH molybdate, tungstate and vanadate exist in several aqueous species, while chromate is present as a single CrO4(2-) species. Consequently, only chromate can be separated from this solution in a sharp chromatographic peak. For obtaining sharp chromatographic peaks for molybdate, tungstate and vanadate, the pH of aqueous standard solutions was raised to 12. At highly alkaline conditions single CrO4(2-), MoO4(2-) and WO4(2-) are present and were eluted in sharp chromatographic peaks, while VO4(3-) species, which predominates at pH 12 was eluted in slightly broaden peak. In a mixture of aqueous standard solutions (pH 12) chromate, molybdate, tungstate and vanadate were eluted at retention times from 380 to 420 s, 320 to 370 s, 300 to 350 s and 240 to 360 s, respectively. Eluted species were simultaneously detected on-line by ICP-MS recording m/z 52, 95, 182 and 51. The developed procedure was successfully applied to the analysis of leachable concentrations of chromate, molybdate, tungstate and vanadate in alkaline extracts (2% NaOH+3% Na2CO3) of manual metal arc (MMA) welding fumes loaded on filters. Good repeatability and reproducibility of measurement (RSD±3.0%) for the investigated species were obtained in both aqueous standard solutions (pH 12) and in alkaline extracts of welding fumes. Low limits of detection (LODs) were found for chromate (0.02 ng Cr mL(-1)), molybdate (0.1 ng Mo mL(-1)), tungstate (0.1 ng W mL(-1)) and vanadate (0.2 ng V mL(-1)). The accuracy of analytical procedure for the determination of chromate was checked by analysis of CRM 545, Cr(VI) in welding dust loaded on a filter. Good agreement between determined and reported certified values was obtained. For molybdate, tungstate and vanadate the assessment of accuracy was performed by spiking welding fume filters. Good recoveries for all investigated species (98-101%) confirmed the accuracy of the analytical procedure. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. EVALUATION OF THE EFFECTIVENESS OF COATINGS IN REDUCING DISLODGEABLE ARSENIC, CHROMIUM, AND COPPER FROM CCA TREATED WOOD; FINAL REPORT

    EPA Science Inventory

    EPA conducted a study to evaluate the effect of coatings on dislodgeable arsenic, chromium, and copper residues on the surfaces of chromated copper arsenate (CAA) treated wood. Dislodgeable CCA, determined by wipe sampling the wood surfaces, was the primary evaluation criterion f...

  20. Color Categories and Color Appearance

    ERIC Educational Resources Information Center

    Webster, Michael A.; Kay, Paul

    2012-01-01

    We examined categorical effects in color appearance in two tasks, which in part differed in the extent to which color naming was explicitly required for the response. In one, we measured the effects of color differences on perceptual grouping for hues that spanned the blue-green boundary, to test whether chromatic differences across the boundary…

  1. Chromatic response of polydiacetylene vesicle induced by the permeation of methotrexate.

    PubMed

    Shin, Min Jae; Kim, Ye Jin; Kim, Jong-Duk

    2015-07-07

    The noble vesicular system of polydiacetylene showed a red shift using two types of detecting systems. One of the systems involves the absorption of target materials from the outer side of the vesicle, and the other system involves the permeation through the vesicular layers from within the vesicle. The chromatic mixed vesicles of N-(2-aminoethyl)pentacosa-10,12-diynamide (AEPCDA) and dimethyldioctadecylammonium chloride (DODAC) were fabricated by sonication, followed by polymerization by UV irradiation. The stability of monomeric vesicles was observed to increase with the polymerization of the vesicles. Methotrexate was used as a target material. The polymerized mixed vesicles having a blue color were exposed to a concentration gradient of methotrexate, and a red shift was observed indicating the adsorption of methotrexate on the polydiacetylene bilayer. In order to check the chromatic change by the permeation of methotrexate, we separated the vesicle portion, which contained methotrexate inside the vesicle, and checked chromatic change during the permeation of methotrexate through the vesicle. The red shift apparently indicates the disturbance in the bilayer induced by the permeation of methotrexate. The maximum contrast of color appeared at the equal molar ratio of AEPCDA and DODAC, indicating that the formation of flexible and deformable vesicular layers is important for red shift. Therefore, it is hypothesized that the system can be applicable for the chromatic detection of the permeation of methotrexate through the polydiacetylene layer.

  2. A maximal chromatic expansion method of mapping multichannel imagery into color space. [North Dakota

    NASA Technical Reports Server (NTRS)

    Juday, R. D.; Abotteen, R. A. (Principal Investigator)

    1978-01-01

    The author has identified the following significant results. A color film generation method that maximally expands the chromaticity and aligns Kauth brightness with the gray axis was presented. In comparison with the current LACIE film product, the new color film product has more contrast and more colors and appears to be brighter. The field boundaries in the new product were more pronounced than in the current LACIE product. The speckle effect was one problem in the new product. The yellowness speckle can be treated using an equation. This equation can be used to eliminate any speckle introduced by the greenness. This product leads logically toward another that will employ quantitative colorimetry which will account for some of the eye's perception of color stimuli.

  3. Experimental Study for Automatic Colony Counting System Based Onimage Processing

    NASA Astrophysics Data System (ADS)

    Fang, Junlong; Li, Wenzhe; Wang, Guoxin

    Colony counting in many colony experiments is detected by manual method at present, therefore it is difficult for man to execute the method quickly and accurately .A new automatic colony counting system was developed. Making use of image-processing technology, a study was made on the feasibility of distinguishing objectively white bacterial colonies from clear plates according to the RGB color theory. An optimal chromatic value was obtained based upon a lot of experiments on the distribution of the chromatic value. It has been proved that the method greatly improves the accuracy and efficiency of the colony counting and the counting result is not affected by using inoculation, shape or size of the colony. It is revealed that automatic detection of colony quantity using image-processing technology could be an effective way.

  4. Chromaticity of the lattice and beam stability in energy recovery linacs

    NASA Astrophysics Data System (ADS)

    Litvinenko, Vladimir N.

    2012-07-01

    Energy recovery linacs (ERLs) are an emerging generation of accelerators that promises to revolutionize the fields of high-energy physics and photon sciences. These accelerators combine the advantages of linear accelerators with that of storage rings, and augur the delivery of electron beams of unprecedented power and quality. The use of superconducting radio-frequency cavities converts ERLs into nearly perfect “perpetuum mobile” accelerators, wherein the beam is accelerated to the desired energy, used, and then yields the energy back to the rf field. However, one potential weakness of these devices is transverse beam breakup instability that could severely limit the available beam current. In this paper, I propose a novel method of suppressing these dangerous effects via a natural phenomenon in the accelerators, viz., the chromaticity of the transverse motion.

  5. COUPLED IRON CORROSION AND CHROMATE REDUCTION: MECHANISMS FOR SUBSURFACE REMEDIATION

    EPA Science Inventory

    The reduction of chromium from the Cr(VI) to the Cr- (Ill) state by the presence of elemental, or zero-oxidation-state, iron metal was studied to evaluate the feasibility of such a process for subsurface chromate remediation. Reactions were studied in systems of natural aquifer m...

  6. Alternatives to chromated copper arsenate for residential construction

    Treesearch

    Stan T. Lebow

    2004-01-01

    For decades chromated copper arsenate (CCA) was the primary preservative for treated wood used in residential construction. However, recent label changes submitted by CCA registrants will withdraw CCA from most residential applications. This action has increased interest in arsenic free preservative systems that have been standardized by the American Wood Preservers...

  7. Reduced Chromatic Discrimination in Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Franklin, Anna; Sowden, Paul; Notman, Leslie; Gonzalez-Dixon, Melissa; West, Dorotea; Alexander, Iona; Loveday, Stephen; White, Alex

    2010-01-01

    Atypical perception in Autism Spectrum Disorders (ASD) is well documented (Dakin & Frith, 2005). However, relatively little is known about colour perception in ASD. Less accurate performance on certain colour tasks has led some to argue that chromatic discrimination is reduced in ASD relative to typical development (Franklin, Sowden, Burley,…

  8. Newborns' Discrimination among Mid- and Long-Wavelength Stimuli.

    ERIC Educational Resources Information Center

    Adams, Russell J.

    1989-01-01

    Data suggest that human newborns are capable of making a chromatic discrimination within the spectral region above 540 nm (the Rayleigh region), but their ability is limited to chromatic stimuli of very wide spectral separation and of very large size. Possible neurological bases underlying this immaturity are discussed. (RH)

  9. Fastener corrosion : testing, research, and design considerations

    Treesearch

    Douglas R. Rammer; Samuel L. Zelinka; Philip Line

    2006-01-01

    In 2004, the voluntary removal of chromated copper arsenate (CCA) from residential wood construction raised concern about corrosion of metal fasteners in wood treated with replacement preservatives. Replacement preservatives contain more copper, which may increase corrosion, and do not contain chromates or arsenates, which are known corrosion inhibitors. This paper is...

  10. WASTE REDUCTION PRACTICES AT TWO CHROMATED COPPER ARSENATE WOOD-TREATING PLANTS

    EPA Science Inventory

    Two chromated copper arsenate (CCA) wood-treating plants were assessed for their waste reduction practices. The objectives of this study were to estimate the amount of hazardous wastes that a well-designed and well-main- tained CCA treatment facility would generate and to iden- t...

  11. Durable Hybrid Coatings

    DTIC Science & Technology

    2011-01-01

    be an adequate alternative for chromate-based coatings [Nanna,   2004] for the protection of aluminum alloys from corrosion . Its protection behavior ...alternative for chromate-based coatings for the protection of aluminum alloys from corrosion . Their protection behavior was attributed to a combination...Topcoat Under Prohesion® Conditions ........ 12 2.4 Remote Corrosion Sensor Design

  12. SIMULTANEOUS DTERMINATION OF CHROMATE AND AROMATIC HYDROCARBONS IN ENVIRONMENTAL SAMPLES BY CAPILLARY ELECTROPHORESIS

    EPA Science Inventory

    An analytical method was developed to determine simultaneously, the inorganic anion CrO2-4, and organic aromatic compounds including benzoate, 2-Cl-benzoate, phenol, m-cresol and o-/p-cresol by capillary electrophoresis (CE). Chromate and the aromatics were separated in a relativ...

  13. Effect of various surfactants on changes in the emission color chromaticity in upconversion YVO4: Yb3+, Er3+ nanoparticles

    NASA Astrophysics Data System (ADS)

    Woźny, Przemysław; Szczeszak, Agata; Lis, Stefan

    2018-02-01

    YVO4: Yb3+,Er3+ upconverting nanocrystals were synthesized via a hydrothermal method using different compounds as surfactants. Structure and morphology of the nanocrystals were investigated by X-ray diffraction and transmission electron microscopy. Tetragonal crystal structure of the nanocrystals appeared irrespective of the type of surfactant used. The average crystallite size was estimated by TEM images. The obtained products were composed of small nanoparticles, in the size range of 10-60 nm, depending on the surfactant used. The morphology of the nanoparticles was also regulated by the type of surfactant. Spectroscopic analysis of the materials obtained was carried out by measuring the emission and excitation spectra and the intensity of luminescence as a function of laser energy and luminescence decays. The nanocrystals prepared exhibited a green upconversion emission attributed to the 2H11/2 → 4I15/2 and 4S3/2 → 4I15/2 transitions of Er3+, under NIR (985 nm) pulse laser irradiation, and their emission lifetimes were in the range 3.84-4.90 μs. On the basis of the spectroscopic investigation, the upconversion mechanism was proposed and chromaticity coordinates were calculated. Surfactants were found to influence on chromaticity of luminescence.

  14. Effect of moisture content on strength of CCA-treated lumber

    Treesearch

    Jerrold E. Winandy

    1995-01-01

    Recent studies on the effects of chromated copper arsenate (CCA) treatment on lumber design properties have primarily evaluated the effects of such treatment at or near 12% moisture content and at failure times of 1 to 10 min. The influence of various moisture contents and faster loading rates is unknown. This report discusses the influence of moisture content and its...

  15. JPRS Report, Science & Technology, USSR: Engineering & Equipment

    DTIC Science & Technology

    1988-07-13

    mono- chromatic waves according to Landau-Lifshits relations and the Maxwell-Garnett relation for effective dielectric permittivity . The agreement...GKNT stemmed from this, and although it renamed the MGDES as a commercial pilot plant, it retained its colossal volume inviolable, i.e., on the

  16. Nitrate effects on chromate reduction in a methane-based biofilm.

    PubMed

    Zhong, Liang; Lai, Chun-Yu; Shi, Ling-Dong; Wang, Kai-Di; Dai, Yu-Jie; Liu, Yao-Wei; Ma, Fang; Rittmann, Bruce E; Zheng, Ping; Zhao, He-Ping

    2017-05-15

    The effects of nitrate (NO 3 - ) on chromate (Cr(VI)) reduction in a membrane biofilm reactor (MBfR) were studied when CH 4 was the sole electron donor supplied with a non-limiting delivery capacity. A high surface loading of NO 3 - gave significant and irreversible inhibition of Cr(VI) reduction. At a surface loading of 500 mg Cr/m 2 -d, the Cr(VI)-removal percentage was 100% when NO 3 - was absent (Stage 1), but was dramatically lowered to < 25% with introduction of 280 mg N m -2 -d NO 3 - (Stage 2). After ∼50 days operation in Stage 2, the Cr(VI) reduction recovered to only ∼70% in Stage 3, when NO 3 - was removed from the influent; thus, NO 3 - had a significant long-term inhibition effect on Cr(VI) reduction. Weighted PCoA and UniFrac analyses proved that the introduction of NO 3 - had a strong impact on the microbial community in the biofilms, and the changes possibly were linked to the irreversible inhibition of Cr(VI) reduction. For example, Meiothermus, the main genus involved in Cr(VI) reduction at first, declined with introduction of NO 3 - . The denitrifier Chitinophagaceae was enriched after the addition of NO 3 - , while Pelomonas became important when nitrate was removed, suggesting its potential role as a Cr(VI) reducer. Moreover, introducing NO 3 - led to a decrease in the number of genes predicted (by PICRUSt) to be related to chromate reduction, but genes predicted to be related to denitrification, methane oxidation, and fermentation increased. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Retinal image contrast obtained by a model eye with combined correction of chromatic and spherical aberrations

    PubMed Central

    Ohnuma, Kazuhiko; Kayanuma, Hiroyuki; Lawu, Tjundewo; Negishi, Kazuno; Yamaguchi, Takefumi; Noda, Toru

    2011-01-01

    Correcting spherical and chromatic aberrations in vitro in human eyes provides substantial visual acuity and contrast sensitivity improvements. We found the same improvement in the retinal images using a model eye with/without correction of longitudinal chromatic aberrations (LCAs) and spherical aberrations (SAs). The model eye included an intraocular lens (IOL) and artificial cornea with human ocular LCAs and average human SAs. The optotypes were illuminated using a D65 light source, and the images were obtained using two-dimensional luminance colorimeter. The contrast improvement from the SA correction was higher than the LCA correction, indicating the benefit of an aspheric achromatic IOL. PMID:21698008

  18. Semantics of color in chromatism

    NASA Astrophysics Data System (ADS)

    Serov, Nikolai V.

    2002-06-01

    The aim of this investigation is to describe the semantics of color in chromatism (from the ancient Greek triune notion of <>: (1) color as ideal (Id- plan), psychic; (2) tint as physical, verbal; material (M- plan), physiological, syntonic (S-plan), and (3) emotion as their informative-energetic correlation). Being a new field of science, chromatism links humanitarian and natural subjects by means of interdiscipline investigation of a real (f-m) man living in a real (color) surrounding environment. According to the definition for <>, color may be considered to be the most universal notion, permitting to assume the unity of both a man and an environment. Due to this assumption, we may give models of human intellect.

  19. In-situ monitoring of undercoating corrosion damage by Direct Optical Interrogation (DOI)

    NASA Astrophysics Data System (ADS)

    Lopez-Garrity, Meng

    An approach referred to as "Direct Optical Interrogation" (DOI) has been developed as an extension of the thin film pitting approach developed and used by Frankel and others. Samples were prepared by depositing Al and Al-Cu alloy metallizations about 800 nm thick on glass substrates. These metallizations were then coated with various coatings and coating systems. Samples were introduced to aggressive environments and the progression of corrosion of the metallization under the coating was monitored in situ using low power videography. Because metallizations were thin, corrosion quickly penetrated through the metal layer to the glass substrate and then spread laterally. Measurement of the lateral spread of corrosion enabled non-electrochemical assessment of the corrosion kinetics. In Al-Cu thin films, both aged and as-deposited, corrosion sites are irregularly shaped because there is not enough cathodic current to propagate the entire corrosion site margin at equal rates. In a number of cases, corrosion propagates with a filamentary morphology resembling filiform corrosion. Cu played a strong role in determining under coating corrosion morphology and growth kinetics in experiments with Al-Cu thin films substrates. As-deposited Al-Cu metallizations were more corrosion resistant than aged metallization and both were more corrosion resistant than pure Al. Cu-rich dendrites were formed on the corrosion front. Corrosion rate (current density) was calculated using Faraday's law by collecting corrosion site perimeter and bottom area. Systematic exploration of the effects of a chromate and chromate-free conversion coatings, chromate and chromate-free primer coatings and the presence or absence of a polyurethane topcoat confirmed the extraordinary corrosion protection by chromates. A commercial praseodymium-pigmented primer coating was not particularly effective in retarding undercoating corrosion site growth unless paired with a chromate conversion coating. The presence of a topcoat dramatically reduces undercoating corrosion and masks many deficiencies of a conversion coating or primer. DOI was used to compare undercoating corrosion that developed due to exposure in ASTM B117, ASTM G85-A5 and outdoor environments. Similar corrosion morphologies developed in ASTM B117 and static immersion exposures. A single and stable corrosions site nucleated and propagated with a filamentary morphology. In general, salt spray exposure was more aggressive than static immersion. ASTM G85-A5 exposure produced different corrosion morphologies. Corrosion sites were round rather than filamentary. Massive nucleation of small corrosion sites across the whole surface also occurred. ASTM G85 environment was mild compared with the ASTM B117 and static immersion exposures. In outdoor exposure testing carried out for 5 months, no signs of corrosion was observed. To assess the extent to which oxygen reduction occurring on the coated surface supported corrosion site growth, a universal pH indicator was added to agar gels or PVB coatings applied on top of metallizations. Color changes indicating pH changes associated with local alkalization or acidification due to local cell action were assessed visually. Overall, the evidence is consistent with the idea that both hydrogen reduction and oxygen reduction support local corrosion site growth. In practical embodiments of corrosion protection, every effort should be made to restrict oxygen reduction to slow corrosion growth rates.

  20. The contributions of Otto Scherzer (1909-1982) to the development of the electron microscope.

    PubMed

    Marko, Michael; Rose, Harald

    2010-08-01

    Otto Scherzer was one of the pioneers of theoretical electron optics. He was coauthor of the first comprehensive book on electron optics and was the first to understand that round electron lenses could not be combined to correct aberrations, as is the case in light optics. He subsequently was the first to describe several alternative means to correct spherical and chromatic aberration of electron lenses. These ideas were put into practice by his laboratory and students at Darmstadt and their successors, leading to the fully corrected electron microscopes now in operation.

  1. Alternatives to chromated copper arsenate (CCA) for residential construction.

    Treesearch

    Stan Lebow

    2004-01-01

    For decades chromated copper arsenate (CCA) was the primary preservative for treated wood used in residential construction. However, recent label changes submitted by CCA registrants will withdraw CCA from most residential applications. This action has increased interest in arsenic-free preservative systems that have been standardized by the American Wood Preservers’...

  2. Human Newborn Color Vision: Measurement with Chromatic Stimuli Varying in Excitation Purity.

    ERIC Educational Resources Information Center

    Adams, Russell J.; Courage, Mary L.

    1998-01-01

    Habituated 180 neonates to white lights of varying luminance and tested for recovery of habituation to green, yellow, or red lights varying in excitation purity. Found that newborns discriminated chromatic stimuli from white only when excitation purity exceeded levels much higher than those for adults. Results reinforce view that neonates' vision…

  3. On the chromatic number of a space with forbidden equilateral triangle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zvonarev, A E; Raigorodskii, A M; Kharlamova, A A

    2014-09-30

    We improve the Frankl-Rödl estimate for the product of the numbers of edges in uniform hypergraphs with forbidden cardinalities of the intersection of edges. By using this estimate, we obtain explicit bounds for the chromatic number of a space with forbidden monochromatic equilateral triangles. Bibliography: 31 titles.

  4. Chromatic Aberration Correction for Atomic Resolution TEM Imaging from 20 to 80 kV.

    PubMed

    Linck, Martin; Hartel, Peter; Uhlemann, Stephan; Kahl, Frank; Müller, Heiko; Zach, Joachim; Haider, Max; Niestadt, Marcel; Bischoff, Maarten; Biskupek, Johannes; Lee, Zhongbo; Lehnert, Tibor; Börrnert, Felix; Rose, Harald; Kaiser, Ute

    2016-08-12

    Atomic resolution in transmission electron microscopy of thin and light-atom materials requires a rigorous reduction of the beam energy to reduce knockon damage. However, at the same time, the chromatic aberration deteriorates the resolution of the TEM image dramatically. Within the framework of the SALVE project, we introduce a newly developed C_{c}/C_{s} corrector that is capable of correcting both the chromatic and the spherical aberration in the range of accelerating voltages from 20 to 80 kV. The corrector allows correcting axial aberrations up to fifth order as well as the dominating off-axial aberrations. Over the entire voltage range, optimum phase-contrast imaging conditions for weak signals from light atoms can be adjusted for an optical aperture of at least 55 mrad. The information transfer within this aperture is no longer limited by chromatic aberrations. We demonstrate the performance of the microscope using the examples of 30 kV phase-contrast TEM images of graphene and molybdenum disulfide, showing unprecedented contrast and resolution that matches image calculations.

  5. Triggerfish uses chromaticity and lightness for object segregation

    PubMed Central

    2017-01-01

    Humans group components of visual patterns according to their colour, and perceive colours separately from shape. This property of human visual perception is the basis behind the Ishihara test for colour deficiency, where an observer is asked to detect a pattern made up of dots of similar colour with variable lightness against a background of dots made from different colour(s) and lightness. To find out if fish use colour for object segregation in a similar manner to humans, we used stimuli inspired by the Ishihara test. Triggerfish (Rhinecanthus aculeatus) were trained to detect a cross constructed from similarly coloured dots against various backgrounds. Fish detected this cross even when it was camouflaged using either achromatic or chromatic noise, but fish relied more on chromatic cues for shape segregation. It remains unknown whether fish may switch to rely primarily on achromatic cues in scenarios where target objects have higher achromatic contrast and lower chromatic contrast. Fish were also able to generalize between stimuli of different colours, suggesting that colour and shape are processed by fish independently. PMID:29308267

  6. Immobilization of chromate in hyperalkaline waste streams by green rusts and zero-valent iron.

    PubMed

    Rogers, Christine M; Burke, Ian T; Ahmed, Imad A M; Shaw, Samuel

    2014-01-01

    Zero-valent iron (ZVI) and green rusts can be used as reductants to convert chromium from soluble, highly toxic Cr(VI) to insoluble Cr(III). This study compared the reduction rates of Cr(VI) by ZVI and two carbonate green rust phases in alkaline/hyperalkaline solutions. Batch experiments were carried out with synthetic chromate solutions at pH 7.7-12.3 and a chromite ore processing residue (COPR) leachate (pH approximately 12.2). Green rust removes chromate from high pH solutions (pH 10-12.5) very rapidly (<400 s). Chromate reduction rates for both green rust phases were consistently higher than for ZVI throughout the pH range studied; the surface area normalized rate constants were two orders of magnitude higher in the COPR leachate solution at pH 12.2. The performances of both green rusts were unaffected by changes in pH. In contrast, ZVI exhibited a marked decline in reduction rate with increasing pH to become almost ineffective above pH12.

  7. A simple handheld pupillometer for chromatic Flicker studies

    NASA Astrophysics Data System (ADS)

    Bernabei, M.; Tinarelli, R.; Peretto, L.; Rovati, L.

    2014-02-01

    A portable pupillometer has been developed which is capable of performing accurate measurements of the pupil diameter during chromatic flicker stimulations. The handheld measuring system records the near-infrared image of the pupil at the rate of 25 fps and simultaneously stimulates the eye using a diffused flicker light generated by light emitting diodes (LEDs). Intensity, frequency and chromatic coordinates of the stimulus can be easily adjusted using a user-friendly graphical interface. Thanks to a chromatic monitoring of the stimulus close to the plane of the eye, photopically matched conditions can be easily achieved. The pupil diameter/area can be measured during flickering stimuli that are generated with frequency in a range of 0.1-20 Hz. The electronic unit, properly connected to the personal computer through a USB port, drives the optical unit, which can be easily held in a hand. The software interface controlling the system was developed in LabVIEW. This paper describes the instrument optical setup, front-end electronics and data processing. Moreover preliminary results obtained on a voluntary are reported.

  8. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution.

    PubMed

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-25

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO 4 ). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO 4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  9. Chromaticity and color saturation of ultraviolet irradiated poly(vinyl alcohol)-anthocyanin coatings

    NASA Astrophysics Data System (ADS)

    Mat Nor, N. A.; Aziz, N.; Mohd-Adnan, A. F.; Taha, R. M.; Arof, A. K.

    2016-06-01

    The purpose of this paper is to evaluate the chromaticity and color saturation of anthocyanin extraction from fruit pericarps of Ixora siamensis in a poly(vinyl alcohol) (PVA) matrix. The colored PVA matrix was exposed to UV-B irradiation for 93 days at UV intensity of 17.55 lux. Anthocyanin colorant has been extracted using methanol acidified with 0.5% trifluoroacetic acid (TFA). Different concentrations of ferulic acid (FA) (0, 1, 2, 3, 4 and 5 wt.%) have been added to the anthocyanin extractions before mixing with PVA to form a coating system. The PVA-anthocyanin-FA mixtures have been coated on glass slides and kept overnight in the dark for curing before exposure to UV-B irradiation. The FA-free sample undergoes more color degradation compared to samples containing FA. The coating with 2% FA has the most stable color with chromaticity of 41% and color saturation of 0.88 compared to other FA containing coats. The FA-free coat exhibits 29% chromaticity and color saturation of 0.38 at the end of the experiment.

  10. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution

    NASA Astrophysics Data System (ADS)

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-01

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO4). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  11. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution

    PubMed Central

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-01-01

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO4). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity. PMID:27779222

  12. The role of egg-nest contrast in the rejection of brood parasitic eggs.

    PubMed

    Aidala, Zachary; Croston, Rebecca; Schwartz, Jessica; Tong, Lainga; Hauber, Mark E

    2015-04-15

    Hosts of avian brood parasites can avoid the reproductive costs of raising genetically unrelated offspring by rejecting parasitic eggs. The perceptual cues and controls mediating parasitic egg discrimination and ejection are well studied: hosts are thought to use differences in egg color, brightness, maculation, size and shape to discriminate between their own and foreign eggs. Most theories of brood parasitism implicitly assume that the primary criteria to which hosts attend when discriminating eggs are differences between the eggs themselves. However, this assumption is confounded by the degree to which chromatic and achromatic characteristics of the nest lining co-vary with egg coloration, so that egg-nest contrast per se might be the recognition cue driving parasitic egg detection. Here, we systematically tested whether and how egg-nest contrast itself contributes to foreign egg discrimination. In an artificial parasitism experiment, we independently manipulated egg color and nest lining color of the egg-ejector American robin (Turdus migratorius), a host of the obligate brood parasitic brown-headed cowbird (Molothrus ater). We hypothesized that the degree of contrast between foreign eggs and the nest background would affect host egg rejection behavior. We predicted that experimentally decreasing egg-nest chromatic and achromatic contrast (i.e. rendering parasitic eggs more cryptic against the nest lining) would decrease rejection rates, while increasing egg-nest contrast would increase rejection rates. In contrast to our predictions, egg-nest contrast was not a significant predictor of egg ejection patterns. Instead, egg color significantly predicted responses to parasitism. We conclude that egg-egg differences are the primary drivers of egg rejection in this system. Future studies should test for the effects of egg-nest contrast per se in predicting parasitic egg recognition in other host-parasite systems, including those hosts building enclosed nests and those parasites laying cryptic eggs, as an alternative to hypothesized effects of egg-egg contrast. © 2015. Published by The Company of Biologists Ltd.

  13. Aircraft Corrosion

    DTIC Science & Technology

    1981-08-01

    protective coating between the plates, the reduction in frictional effects caused by the fluid did cause a significant reduction in fatigue life ... surface treatments for aluminum alloys , there has been a return to anodizing for new weapons systems rather than chromate conversion coatings . Both sulfuric...good alternate coating material in many applications requiring good corrosion resistance and minimal effect on fatigue properties. Only two aluminum

  14. ARSENATE AND ARSENITE REMOVAL BY ZERO-VALENT IRON: EFFECTS OF PHOSPHATE, SILICATE, CARBONATE, BORATE, SULFATE, CHROMATE, MOLYBDATE, AND NITRATE, RELATIVE TO CHLORIDE

    EPA Science Inventory

    Batch tests were performed to evaluate the effects of inorganic anion competition on the kinetics of arsenate (As(V)) and arsenite (As(III)) removal by zerovalent iron (Peerless Fe0) in aqueous solution. The oxyanions underwent either sorption-dominated reactions (phosphate, sil...

  15. Evaluation and control of environmental corrosion for aluminum and steel alloys

    NASA Technical Reports Server (NTRS)

    Franklin, D. B.

    1977-01-01

    Corrosion protection systems for aerospace application and the effects of surface treatments and methods of controlling stress corrosion are evaluated. Chromate pigmented systems were found to be most effective for aluminum alloys; zinc-rich coatings gave the greatest protection to steel alloys. Various steel and aluminum alloys are rated for stress corrosion resistance.

  16. Design of long induction linacs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caporaso, G.J.; Cole, A.G.

    1990-09-06

    A self-consistent design strategy for induction linacs is presented which addresses the issues of brightness preservation against space charge induced emittance growth, minimization of the beam breakup instability and the suppression of beam centroid motion due to chromatic effects (corkscrew) and misaligned focusing elements. A simple steering algorithm is described that widens the effective energy bandwidth of the transport system.

  17. Lightness and Hue Perception: The Bezold-Brucke Effect and Colour Basic Categories

    ERIC Educational Resources Information Center

    Lillo, Julio; Aguado, Luis; Moreira, Humberto; Davies, Ian

    2004-01-01

    Using surface colours as stimuli, the present research was aimed at the two following goals: (1) To determine the chromatic angles related to categorical effects type B-B (Bezold-Brucke). (2) To determine the colourimetric characteristics compatible with each Spanish colour basic category. To get these goals the full set of tiles included in the…

  18. Downwelling spectral irradiance during evening twilight as a function of the lunar phase.

    PubMed

    Palmer, Glenn; Johnsen, Sönke

    2015-02-01

    We measured downwelling spectral vector irradiance (from 350 to 800 nm) during evening civil and nautical twilight (solar elevation down to -12°). Nine sets of measurements were taken to cover the first half of the lunar cycle (from the new to full moon) and were also used to calculate chromaticity (CIE 1976 u'v'). The lunar phase had no consistent effect on downwelling irradiance until solar elevation was less than -8°. For lower solar elevations, the effect of the moon increased with the fraction of the illuminated lunar disk until the fraction was approximately 50%. For fractions greater than 50%, the brightness and chromaticity of the downwelling irradiance were approximately independent of the fraction illuminated, likely because the greater brightness of a fuller moon was offset by its lower elevation during twilight. Given the importance of crepuscular periods to animal activity, including predation, reproductive cycles, and color vision in dim light, these results may have significant implications for animal ecology.

  19. An analytical method to simulate the H I 21-cm visibility signal for intensity mapping experiments

    NASA Astrophysics Data System (ADS)

    Sarkar, Anjan Kumar; Bharadwaj, Somnath; Marthi, Visweshwar Ram

    2018-01-01

    Simulations play a vital role in testing and validating H I 21-cm power spectrum estimation techniques. Conventional methods use techniques like N-body simulations to simulate the sky signal which is then passed through a model of the instrument. This makes it necessary to simulate the H I distribution in a large cosmological volume, and incorporate both the light-cone effect and the telescope's chromatic response. The computational requirements may be particularly large if one wishes to simulate many realizations of the signal. In this paper, we present an analytical method to simulate the H I visibility signal. This is particularly efficient if one wishes to simulate a large number of realizations of the signal. Our method is based on theoretical predictions of the visibility correlation which incorporate both the light-cone effect and the telescope's chromatic response. We have demonstrated this method by applying it to simulate the H I visibility signal for the upcoming Ooty Wide Field Array Phase I.

  20. Effect of Sn4+ Additives on the Microstructure and Corrosion Resistance of Anodic Coating Formed on AZ31 Magnesium Alloy in Alkaline Solution

    NASA Astrophysics Data System (ADS)

    Salman, S. A.; Kuroda, K.; Saito, N.; Okido, M.

    Magnesium is the lightest structural metal with high specific strength and good mechanical properties. However, poor corrosion resistance limits its widespread use in many applications. Magnesium is usually treated with Chromate conversion coatings. However, due to changing environmental regulations and pollution prevention requirements, a significant push exists to find new, alternative for poisonous Cr6+. Therefore, we aim to improve corrosion resistance of anodic coatings on AZ31 alloys using low cost non-chromate electrolyte. Anodizing was carried out in alkaline solutions with tin additives. The effect of tin additives on the coating film was characterized by SEM and XRD. The corrosion resistance was evaluated using anodic and cathodic polarizations and electrochemical impedance spectroscopy (EIS). Corrosion resistance property was improved with tin additives and the best anti-corrosion property was obtained with addition of 0.03 M Na2SnO3.3H2O to anodizing solution.

  1. Red-green opponent channel mediation of control of human ocular accommodation.

    PubMed Central

    Kotulak, J C; Morse, S E; Billock, V A

    1995-01-01

    1. It has been hypothesized, but not verified empirically, that the control of human ocular accommodation is mediated by either the red-green or yellow-blue colour channels. Our goal was to determine experimentally whether the red-green channel by itself could influence the accommodative response. 2. To find out, we isolated the red-green channel through chromatic bandpass filtering and measured accommodation under dynamic and static conditions. The effect of this filtering was to modulate the red-green channel without disturbing either the yellow-blue or luminance channels. 3. Accommodative gain (ratio of response to stimulus amplitude) declined monotonically with decreasing bandwidth under dynamic conditions. Because the outputs of both the luminance and yellow-blue colour channels did not vary with bandwidth, the only explanation is that the red-green opponent process was responsible for the effect. 4. Under static conditions, however, accommodation was independent of bandwidth. This may be attributable to the decreased sensitivity to chromatic contrast that occurs at low temporal frequencies. PMID:7738858

  2. Cloning and sequence analysis demonstrate the chromate reduction ability of a novel chromate reductase gene from Serratia sp.

    PubMed

    Deng, Peng; Tan, Xiaoqing; Wu, Ying; Bai, Qunhua; Jia, Yan; Xiao, Hong

    2015-03-01

    The ChrT gene encodes a chromate reductase enzyme which catalyzes the reduction of Cr(VI). The chromate reductase is also known as flavin mononucleotide (FMN) reductase (FMN_red). The aim of the present study was to clone the full-length ChrT DNA from Serratia sp. CQMUS2 and analyze the deduced amino acid sequence and three-dimensional structure. The putative ChrT gene fragment of Serratia sp. CQMUS2 was isolated by polymerase chain reaction (PCR), according to the known FMN_red gene sequence from Serratia sp. AS13. The flanking sequences of the ChrT gene were obtained by high efficiency TAIL-PCR, while the full-length gene of ChrT was cloned in Escherichia coli for subsequent sequencing. The nucleotide sequence of ChrT was submitted onto GenBank under the accession number, KF211434. Sequence analysis of the gene and amino acids was conducted using the Basic Local Alignment Search Tool, and open reading frame (ORF) analysis was performed using ORF Finder software. The ChrT gene was found to be an ORF of 567 bp that encodes a 188-amino acid enzyme with a calculated molecular weight of 20.4 kDa. In addition, the ChrT protein was hypothesized to be an NADPH-dependent FMN_red and a member of the flavodoxin-2 superfamily. The amino acid sequence of ChrT showed high sequence similarity to the FMN reductase genes of Klebsiella pneumonia and Raoultella ornithinolytica , which belong to the flavodoxin-2 superfamily. Furthermore, ChrT was shown to have a 85.6% similarity to the three-dimensional structure of Escherichia coli ChrR, sharing four common enzyme active sites for chromate reduction. Therefore, ChrT gene cloning and protein structure determination demonstrated the ability of the gene for chromate reduction. The results of the present study provide a basis for further studies on ChrT gene expression and protein function.

  3. Cloning and sequence analysis demonstrate the chromate reduction ability of a novel chromate reductase gene from Serratia sp

    PubMed Central

    DENG, PENG; TAN, XIAOQING; WU, YING; BAI, QUNHUA; JIA, YAN; XIAO, HONG

    2015-01-01

    The ChrT gene encodes a chromate reductase enzyme which catalyzes the reduction of Cr(VI). The chromate reductase is also known as flavin mononucleotide (FMN) reductase (FMN_red). The aim of the present study was to clone the full-length ChrT DNA from Serratia sp. CQMUS2 and analyze the deduced amino acid sequence and three-dimensional structure. The putative ChrT gene fragment of Serratia sp. CQMUS2 was isolated by polymerase chain reaction (PCR), according to the known FMN_red gene sequence from Serratia sp. AS13. The flanking sequences of the ChrT gene were obtained by high efficiency TAIL-PCR, while the full-length gene of ChrT was cloned in Escherichia coli for subsequent sequencing. The nucleotide sequence of ChrT was submitted onto GenBank under the accession number, KF211434. Sequence analysis of the gene and amino acids was conducted using the Basic Local Alignment Search Tool, and open reading frame (ORF) analysis was performed using ORF Finder software. The ChrT gene was found to be an ORF of 567 bp that encodes a 188-amino acid enzyme with a calculated molecular weight of 20.4 kDa. In addition, the ChrT protein was hypothesized to be an NADPH-dependent FMN_red and a member of the flavodoxin-2 superfamily. The amino acid sequence of ChrT showed high sequence similarity to the FMN reductase genes of Klebsiella pneumonia and Raoultella ornithinolytica, which belong to the flavodoxin-2 superfamily. Furthermore, ChrT was shown to have a 85.6% similarity to the three-dimensional structure of Escherichia coli ChrR, sharing four common enzyme active sites for chromate reduction. Therefore, ChrT gene cloning and protein structure determination demonstrated the ability of the gene for chromate reduction. The results of the present study provide a basis for further studies on ChrT gene expression and protein function. PMID:25667630

  4. Modeling the Effects of Mirror Misalignment in a Ring Imaging Cherenkov Detector

    NASA Astrophysics Data System (ADS)

    Hitchcock, Tawanda; Harton, Austin; Garcia, Edmundo

    2012-03-01

    The Very High Momentum Particle Identification Detector (VHMPID) has been proposed for the ALICE experiment at the Large Hadron Collider (LHC). This detector upgrade is considered necessary to study jet-matter interaction at high energies. The VHMPID identifies charged hadrons in the 5 GeV/c to 25 GeV/c momentum range. The Cherenkov photons emitted in the VHMPID radiator are collected by spherical mirrors and focused onto a photo-detector plane forming a ring image. The radius of this ring is related to the Cherenkov angle, this information coupled with the particle momentum allows the particle identification. A major issue in the RICH detector is that environmental conditions can cause movements in mirror position. In addition, chromatic dispersion causes the refractive index to shift, altering the Cherenkov angle. We are modeling a twelve mirror RICH detector taking into account the effects of mirror misalignment and chromatic dispersion using a commercial optical software package. This will include quantifying the effects of both rotational and translational mirror misalignment for the initial assembly of the module and later on particle identification.

  5. [Standard addition determination of impurities in Na2CrO4 by ICP-AES].

    PubMed

    Wang, Li-ping; Feng, Hai-tao; Dong, Ya-ping; Peng, Jiao-yu; Li, Wu; Shi, Hai-qin; Wang, Yong

    2015-02-01

    Coupled plasma atomic emission spectrometry (ICP-AES) was used to determine the trace impurities of Ca, Mg, Al, Fe and Si in industrial sodium chromate. Wavelengths of 167.079, 393.366, 259.940, 279.533 and 251.611 nm were selected as analytical lines for the determination of Al, Ca, Fe, Mg and Si, respectively. The analytical errors can be eliminated by adjusting the determined solution with high pure hydrochloric acid. Standard addition method was used to eliminate matrix effects. The linear correlation, detection limit, precision and recovery for the concerned trace impurities have been examined. The effect of standard addition method on the accuracy for the determination under the selected analytical lines has been studied in detail. The results show that the linear correlations of standard curves were very good (R2 = 0.9988 to 0.9996) under the determined conditions. Detection limits of these trace impurities were in the range of 0.0134 to 0.0280 mg x L(-1). Sample recoveries were within 97.30% to 107.50%, and relative standard deviations were lower than 5.86% for eleven repeated determinations. The detection limits and accuracies established by the experiment can meet the analytical requirements and the analytic procedure was used to determine trace impurities in sodium chromate by ion membrane electrolysis technique successfully. Due to sodium chromate can be changed into sodium dichromate and chromic acid by adding acids, the established method can be further used to monitor trace impurities in these compounds or other hexavalent chromium compounds.

  6. Chromatically encoded high-speed photography of cavitation bubble dynamics inside inhomogeneous ophthalmic tissue

    NASA Astrophysics Data System (ADS)

    Tinne, N.; Matthias, B.; Kranert, F.; Wetzel, C.; Krüger, A.; Ripken, T.

    2016-03-01

    The interaction effect of photodisruption, which is used for dissection of biological tissue with fs-laser pulses, has been intensively studied inside water as prevalent sample medium. In this case, the single effect is highly reproducible and, hence, the method of time-resolved photography is sufficiently applicable. In contrast, the reproducibility significantly decreases analyzing more solid and anisotropic media like biological tissue. Therefore, a high-speed photographic approach is necessary in this case. The presented study introduces a novel technique for high-speed photography based on the principle of chromatic encoding. For illumination of the region of interest within the sample medium, the light paths of up to 12 LEDs with various emission wavelengths are overlaid via optical filters. Here, MOSFET-electronics provide a LED flash with a duration <100 ns; the diodes are externally triggered with a distinct delay for every LED. Furthermore, the different illumination wavelengths are chromatically separated again for detection via camera chip. Thus, the experimental setup enables the generation of a time-sequence of <= 12 images of a single cavitation bubble dynamics. In comparison to conventional time-resolved photography, images in sample media like water and HEMA show the significant advantages of this novel illumination technique. In conclusion, the results of this study are of great importance for the fundamental evaluation of the laser-tissue interaction inside anisotropic biological tissue and for the optimization of the surgical process with high-repetition rate fs-lasers. Additionally, this application is also suitable for the investigation of other microscopic, ultra-fast events in transparent inhomogeneous materials.

  7. User-preferred color temperature adjustment for smartphone display under varying illuminants

    NASA Astrophysics Data System (ADS)

    Choi, Kyungah; Suk, Hyeon-Jeong

    2014-06-01

    The study aims to investigate the user-preferred color temperature adjustment for smartphone displays by observing the effect of the illuminant's chromaticity and intensity on the optimal white points preferred by users. For visual examination, subjects evaluated 14 display stimuli presented on the Samsung Galaxy S3 under 19 ambient illuminants. The display stimuli were composed of 14 nuanced whites varying in color temperature from 2900 to 18,900 K. The illuminant conditions varied with combinations of color temperature (2600 to 20,100 K) and illuminance level (30 to 3100 lx) that simulated daily lighting experiences. The subjects were asked to assess the optimal level of the display color temperatures based on their mental representation of the ideal white point. The study observed a positive correlation between the illuminant color temperatures and the optimal display color temperatures (r=0.89, p<0.05). However, the range of the color temperature of the smartphone display was much narrower than that of the illuminants. Based on the assessments by 100 subjects, a regression formula was derived to predict the adjustment of user-preferred color temperature under changing illuminant chromaticity. The formula is as follows: [Display Tcp=6534.75 log (Illuminant Tcp)-16304.68 (R=0.87, p<0.05)]. Moreover, supporting previous studies on color reproduction, the effect of illuminant chromaticity was relatively weaker under lower illuminance. The results of this experiment could be used as a theoretical basis for designers and manufacturers to adjust user-preferred color temperature for smartphone displays under various illuminant conditions.

  8. Tuning of the emission color of organic light emitting diodes via smartly designed aluminum plasmonics

    NASA Astrophysics Data System (ADS)

    Auer-Berger, Manuel; Tretnak, Veronika; Wenzl, Franz-Peter; Krenn, Joachim; List-Kratochvil, Emil J. W.

    2017-02-01

    With the invention of phosphorescent emitter material, organic light emitting diodes with internal quantum yields of up to 100% can be realized. Still, the extraction of the light from the OLED stack is a bottleneck, which hampers the availability of OLEDs with large external quantum efficiencies. In this contribution, we highlight the advantages of integrating aluminum nanodisc arrays into the OLED stack. By this, not only the out-coupling of light can be enhanced, but also the emission color can be tailored and controlled. By means of extinction- and fluorescence spectroscopy measurements we are able to show how the sharp features observed in the extinction measurements correlate with a very selective fluorescence enhancement of the organic emitter materials used in these studies. At the same time, localized surface plasmon resonances of the individual nanodiscs further modify the emission spectrum, e.g., by filtering the green emission tail. A combination of these factors leads to a modification of the emission color in between CIE1931 (x,y) chromaticity coordinates of (0.149, 0.225) and (0.152, 0.352). After accounting for the sensitivity of the human eye, we are able to demonstrate that this adjustment of the chromaticity coordinates goes is accompanied by an increase in device efficiency.

  9. Chromaticity of the lattice and beam stability in energy-recovery linacs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litvinenko, V.N.

    2011-12-23

    Energy recovery linacs (ERLs) are an emerging generation of accelerators promising to revolutionize the fields of high-energy physics and photon sciences. These accelerators combine the advantages of linear accelerators with that of storage rings, and hold the promise of delivering electron beams of unprecedented power and quality. Use of superconducting radio-frequency (SRF) cavities converts ERLs into nearly perfect 'perpetuum mobile' accelerators, wherein the beam is accelerated to a desirable energy, used, and then gives the energy back to the RF field. One potential weakness of these devices is transverse beam break-up instability that could severely limit the available beam current.more » In this paper, I present a method of suppressing these dangerous effects using a natural phenomenon in the accelerators, viz., the chromaticity of the transverse motion.« less

  10. Motion robust remote photoplethysmography in CIELab color space

    NASA Astrophysics Data System (ADS)

    Yang, Yuting; Liu, Chenbin; Yu, Hui; Shao, Dangdang; Tsow, Francis; Tao, Nongjian

    2016-11-01

    Remote photoplethysmography (rPPG) is attractive for tracking a subject's physiological parameters without wearing a device. However, rPPG is known to be prone to body movement-induced artifacts, making it unreliable in realistic situations. Here we report a method to minimize the movement-induced artifacts. The method selects an optimal region of interest (ROI) automatically, prunes frames in which the ROI is not clearly captured (e.g., subject moves out of the view), and analyzes rPPG using an algorithm in CIELab color space, rather than the widely used RGB color space. We show that body movement primarily affects image intensity, rather than chromaticity, and separating chromaticity from intensity in CIELab color space thus helps achieve effective reduction of the movement-induced artifacts. We validate the method by performing a pilot study including 17 people with diverse skin tones.

  11. Equal Insistence of Proportion of Colour on a 2D Surface

    NASA Astrophysics Data System (ADS)

    Staig-Graham, B. N.

    2006-06-01

    Katz conducted experiments on Insistence and Equal Insistence, using an episcotister, chromatic, and achromatic papers which he viewed under different intensities of a light sources and chromatic illumination. His principle of Equal Insistence, combined with Goethe's reputed proportions of surface colours according to their luminosity, and Strzeminski's concept of Unism in painting inspire the author's current painting practice. However, a whole new route of research has been opened by the introduction of Time as a phenomenon of Equal Insitence and Image Perception Fading, under contolled conditions of observer movement at different distances, viewing angles, and illumination. Visual knowledge of Equal Insistence indicates, so far, several apparent changes to the properties of surface colours, and its actual effect upon the shape and size of paintings and symbolism. Typical of the investigation are the achromatic images of an elephant and a mouse.

  12. New Approach to Remove Metals from Chromated Copper Arsenate (CCA)-Treated Wood

    Treesearch

    Todd F. Shupe; Chung Y. Hse; Hui Pan

    2012-01-01

    Recovery of metals from chromated copper arsenate (CCA)-treated southern pine wood particles was investigated using binary acid solutions consisting of acetic, oxalic, and phosphoric acids in a microwave reactor. Formation of an insoluble copper oxalate complex in the binary solution containing oxalic acid was the major factor for low copper removal. Furthermore, the...

  13. Development of Chromatic Induction in Infancy

    ERIC Educational Resources Information Center

    Okamura, Hiromi; Kanazawa, So; Yamaguchi, Masami K.

    2007-01-01

    The perception of colour in an embedded field is affected by the surround colour. This phenomenon is known as chromatic induction. In the present study we investigated whether the colour perception by infants aged 5-7 months could be affected by the surround colour. In Experiments 1 and 2 each stimulus was composed of an array of six squares in…

  14. CALiPER Report 20.4: Lumen and Chromaticity Maintenance of LED PAR38 Lamps Operated in Steady-State Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2014-12-30

    This CALiPER report focuses on lumen maintenance, chromaticity maintenance, and catastrophic failure in 32 of the Series 20 LED PAR38 lamps and 8 benchmark lamps, which were monitored for nearly 14,000 hours at ambient temperatures between 44°C and 45°C.

  15. Testing of Environmentally Preferable Aluminum Pretreatments and Coating Systems for Use on Space Shuttle Solid Rocket Boosters (SRB)

    NASA Technical Reports Server (NTRS)

    Clayton, C.; Raley, R.; Zook, L.

    2001-01-01

    The solid rocket booster (SRB) has historically used a chromate conversion coating prior to protective finish application. After conversion coating, an organic paint system consisting of a chromated epoxy primer and polyurethane topcoat is applied. An overall systems approach was selected to reduce waste generation from the coatings application and removal processes. While the most obvious waste reduction opportunity involved elimination of the chromate conversion coating, several other coating system configurations were explored in an attempt to reduce the total waste. This paper will briefly discuss the use of a systems view to reduce waste generation from the coating process and present the results of the qualification testing of nonchromated aluminum pretreatments and alternate coating systems configurations.

  16. Optical frequency-domain chromatic dispersion measurement method for higher-order modes in an optical fiber.

    PubMed

    Ahn, Tae-Jung; Jung, Yongmin; Oh, Kyunghwan; Kim, Dug Young

    2005-12-12

    We propose a new chromatic dispersion measurement method for the higher-order modes of an optical fiber using optical frequency modulated continuous-wave (FMCW) interferometry. An optical fiber which supports few excited modes was prepared for our experiments. Three different guiding modes of the fiber were identified by using far-field spatial beam profile measurements and confirmed with numerical mode analysis. By using the principle of a conventional FMWC interferometry with a tunable external cavity laser, we have demonstrated that the chromatic dispersion of a few-mode optical fiber can be obtained directly and quantitatively as well as qualitatively. We have also compared our measurement results with those of conventional modulation phase-shift method.

  17. In vitro bioaccessibility of copper azole following simulated dermal transfer from pressure-treated wood

    EPA Science Inventory

    Micronized copper azole (MCA) and micronized copper quaternary are the latest wood preservatives to replace the liquid lkaline copper and chromated copper arsenate preservatives due to concerns over the toxicity or lack of effectiveness of the earlier formulations. Today, the use...

  18. Effects of oxidizing adulterants on detection of 11-nor-delta9-THC-9-carboxylic acid in urine.

    PubMed

    Paul, Buddha D; Jacobs, Aaron

    2002-10-01

    Bleach, nitrite, chromate, and hydrogen peroxide-peroxidase are effective urine adulterants used by the illicit drug users to conceal marijuana-positive results. Methods for detecting nitrite and chromate are available. Effects of other oxidizing agents that could possibly be used as adulterants and are difficult to detect or measure are presented in this report. Urine samples containing 40 ng/mL of 11-nor-delta9-THC-9-carboxylic acid (THC-acid) were treated with 10 mmol/L of commonly available oxidizing agents. Effects of horseradish peroxidase of activity 10 unit/mL and extracts from 2.5 g of red radish (Raphanus sativus, Radicula group), horseradish (Armoracia rusticana), Japanese radish (Raphanus sativus, Daikon group), and black mustard seeds (Brassica nigra), all with 10 mmol/L of hydrogen peroxide, were also examined. After 5 min, 16 h and 48 h of exposure at room temperature (23 degrees C) the specimens were tested by a gas chromatographic-mass spectrometric method for THC-acid. A control group treated with sodium hydrosulfite to reduce the oxidants, was also tested to investigate the effect of oxidizing agents on THC-acid in the extraction method. THC-acid was lost completely in the extraction method when treated with chromate, nitrite, oxone, and hydrogen peroxide/ferrous ammonium sulfate (Fenton's reagent). Some losses were also observed with persulfate and periodate (up to 25%). These oxidants, and other oxidizing agents like permanganate, periodate, peroxidase, and extracts from red radish, horseradish, Japanese radish and black mustard seeds destroyed most of the THC-acid (> 94%) within 48 h of exposure. Chlorate, perchlorate, iodate, and oxychloride under these conditions showed little or no effect. Complete loss was observed when THC-acid was exposed to 50 mmol/L of oxychloride for 48 h. Several oxidizing adulterants that are difficult to test by the present urine adulterant testing methods showed considerable effects on the destruction of THC-acid. The time and temperature for these effects were similar to those used by most laboratories to collect and test specimens. In several cases, the loss of THC-acid was > 94%.

  19. Color appearance of familiar objects: effects of object shape, texture, and illumination changes.

    PubMed

    Olkkonen, Maria; Hansen, Thorsten; Gegenfurtner, Karl R

    2008-05-26

    People perceive roughly constant surface colors despite large changes in illumination. The familiarity of colors of some natural objects might help achieve this feat through direct modulation of the objects' color appearance. Research on memory colors and color appearance has yielded controversial results and due to the employed methods has often confounded perceptual with semantic effects. We studied the effect of memory colors on color appearance by presenting photographs of fruit on a monitor under various simulated illuminations and by asking observers to make either achromatic or typical color settings without placing demands on short-term memory or semantic processing. In a control condition, we presented photographs of 3D fruit shapes without texture and 2D outline shapes. We found that (1) achromatic settings for fruit were systematically biased away from the gray point toward the opposite direction of a fruit's memory color; (2) the strength of the effect depended on the degree of naturalness of the stimuli; and (3) the effect was evident under all tested illuminations, being strongest for illuminations whose chromaticity was closest to the stimulus chromaticity. We conclude that the visual identity of an object has a measurable effect on color perception, and that this effect is robust under illuminant changes, indicating its potential significance as an additional mechanism for color constancy.

  20. Effects of coloured lighting on the perception of interior spaces.

    PubMed

    Odabaşioğlu, Seden; Olguntürk, Nіlgün

    2015-02-01

    Use of coloured lighting in interior spaces has become prevalent in recent years. Considerable importance is ascribed to coloured lighting in interior and lighting design. The effects of colour on the perception of interior spaces have been studied as surface colour; but here, the effects of three different types of chromatic light were investigated. The lighting differed in colour (red, green and white) and perceptions of interior space were assessed. 97 participants (59 women, 38 men; M age = 21.4 yr.) evaluated the experiment room on a questionnaire assessing eight evaluative factors: Pleasantness, Arousal, Aesthetics, Usefulness, Comfort, Spaciousness, Colour, and Lighting quality. Perceptions of the room differed by colour of lighting for some of the evaluative factors, but there was no sex difference in perceptions. Interior spaces may be perceived as equally pleasant under white, green and red lighting. Under white lighting a space is perceived as more useful, spacious, clear, and luminous. Green lighting would make the same effect. Green and white lighting were perceived equally comfortable in an interior space. Chromatic coloured lighting was perceived to be more aesthetic than white lighting. The results support previous findings for some evaluative factors, but differed for others.

  1. Investigating Neuromagnetic Brain Responses against Chromatic Flickering Stimuli by Wavelet Entropies

    PubMed Central

    Bhagat, Mayank; Bhushan, Chitresh; Saha, Goutam; Shimjo, Shinsuke; Watanabe, Katsumi; Bhattacharya, Joydeep

    2009-01-01

    Background Photosensitive epilepsy is a type of reflexive epilepsy triggered by various visual stimuli including colourful ones. Despite the ubiquitous presence of colorful displays, brain responses against different colour combinations are not properly studied. Methodology/Principal Findings Here, we studied the photosensitivity of the human brain against three types of chromatic flickering stimuli by recording neuromagnetic brain responses (magnetoencephalogram, MEG) from nine adult controls, an unmedicated patient, a medicated patient, and two controls age-matched with patients. Dynamical complexities of MEG signals were investigated by a family of wavelet entropies. Wavelet entropy is a newly proposed measure to characterize large scale brain responses, which quantifies the degree of order/disorder associated with a multi-frequency signal response. In particular, we found that as compared to the unmedicated patient, controls showed significantly larger wavelet entropy values. We also found that Renyi entropy is the most powerful feature for the participant classification. Finally, we also demonstrated the effect of combinational chromatic sensitivity on the underlying order/disorder in MEG signals. Conclusions/Significance Our results suggest that when perturbed by potentially epileptic-triggering stimulus, healthy human brain manages to maintain a non-deterministic, possibly nonlinear state, with high degree of disorder, but an epileptic brain represents a highly ordered state which making it prone to hyper-excitation. Further, certain colour combination was found to be more threatening than other combinations. PMID:19779630

  2. Investigating neuromagnetic brain responses against chromatic flickering stimuli by wavelet entropies.

    PubMed

    Bhagat, Mayank; Bhushan, Chitresh; Saha, Goutam; Shimjo, Shinsuke; Watanabe, Katsumi; Bhattacharya, Joydeep

    2009-09-25

    Photosensitive epilepsy is a type of reflexive epilepsy triggered by various visual stimuli including colourful ones. Despite the ubiquitous presence of colorful displays, brain responses against different colour combinations are not properly studied. Here, we studied the photosensitivity of the human brain against three types of chromatic flickering stimuli by recording neuromagnetic brain responses (magnetoencephalogram, MEG) from nine adult controls, an unmedicated patient, a medicated patient, and two controls age-matched with patients. Dynamical complexities of MEG signals were investigated by a family of wavelet entropies. Wavelet entropy is a newly proposed measure to characterize large scale brain responses, which quantifies the degree of order/disorder associated with a multi-frequency signal response. In particular, we found that as compared to the unmedicated patient, controls showed significantly larger wavelet entropy values. We also found that Renyi entropy is the most powerful feature for the participant classification. Finally, we also demonstrated the effect of combinational chromatic sensitivity on the underlying order/disorder in MEG signals. Our results suggest that when perturbed by potentially epileptic-triggering stimulus, healthy human brain manages to maintain a non-deterministic, possibly nonlinear state, with high degree of disorder, but an epileptic brain represents a highly ordered state which making it prone to hyper-excitation. Further, certain colour combination was found to be more threatening than other combinations.

  3. [Current contact allergens].

    PubMed

    Geier, J; Uter, W; Lessmann, H; Schnuch, A

    2011-10-01

    Ever-changing exposure to contact allergens, partly due to statutory directives (e.g. nickel, chromate, methyldibromo glutaronitrile) or recommendations from industrial associations (e.g. hydroxyisohexyl 3-cyclohexene carboxaldehyde), requires on-going epidemiologic surveillance of contact allergy. In this paper, the current state with special focus in fragrances and preservatives is described on the basis of data of the Information Network of Departments of Dermatology (IVDK) of the year 2010. In 2010, 12,574 patients were patch tested in the dermatology departments belonging to the IVDK. Nickel is still the most frequent contact allergen. However the continuously improved EU nickel directive already has some beneficial effect; sensitization frequency in young women is dropping. In Germany, chromate-reduced cement has been in use now for several years, leading to a decline in chromate sensitization in brick-layers. Two fragrance mixes are part of the German baseline series; they are still relevant. The most important fragrances in these mixes still are oak moss absolute and hydroxyisohexyl 3-cyclohexene carboxaldehyde. However, in relation to these leading allergens, sensitization frequency to other fragrances contained in the mixes seems to be increasing. Among the preservatives, MCI/MI has not lost its importance as contact allergen, in contrast to MDBGN. Sources of MCI/MI sensitization obviously are increasingly found in occupational context. Methylisothiazolinone is a significant allergen in occupational settings, and less frequently in body care products.

  4. Individual variation in cone photoreceptor density in house sparrows: implications for between-individual differences in visual resolution and chromatic contrast.

    PubMed

    Ensminger, Amanda L; Fernández-Juricic, Esteban

    2014-01-01

    Between-individual variation has been documented in a wide variety of taxa, especially for behavioral characteristics; however, intra-population variation in sensory systems has not received similar attention in wild animals. We measured a key trait of the visual system, the density of retinal cone photoreceptors, in a wild population of house sparrows (Passer domesticus). We tested whether individuals differed from each other in cone densities given within-individual variation across the retina and across eyes. We further tested whether the existing variation could lead to individual differences in two aspects of perception: visual resolution and chromatic contrast. We found consistent between-individual variation in the densities of all five types of avian cones, involved in chromatic and achromatic vision. Using perceptual modeling, we found that this degree of variation translated into significant between-individual differences in visual resolution and the chromatic contrast of a plumage signal that has been associated with mate choice and agonistic interactions. However, there was no evidence for a relationship between individual visual resolution and chromatic contrast. The implication is that some birds may have the sensory potential to perform "better" in certain visual tasks, but not necessarily in both resolution and contrast simultaneously. Overall, our findings (a) highlight the need to consider multiple individuals when characterizing sensory traits of a species, and (b) provide some mechanistic basis for between-individual variation in different behaviors (i.e., animal personalities) and for testing the predictions of several widely accepted hypotheses (e.g., honest signaling).

  5. Individual Variation in Cone Photoreceptor Density in House Sparrows: Implications for Between-Individual Differences in Visual Resolution and Chromatic Contrast

    PubMed Central

    Ensminger, Amanda L.; Fernández-Juricic, Esteban

    2014-01-01

    Between-individual variation has been documented in a wide variety of taxa, especially for behavioral characteristics; however, intra-population variation in sensory systems has not received similar attention in wild animals. We measured a key trait of the visual system, the density of retinal cone photoreceptors, in a wild population of house sparrows (Passer domesticus). We tested whether individuals differed from each other in cone densities given within-individual variation across the retina and across eyes. We further tested whether the existing variation could lead to individual differences in two aspects of perception: visual resolution and chromatic contrast. We found consistent between-individual variation in the densities of all five types of avian cones, involved in chromatic and achromatic vision. Using perceptual modeling, we found that this degree of variation translated into significant between-individual differences in visual resolution and the chromatic contrast of a plumage signal that has been associated with mate choice and agonistic interactions. However, there was no evidence for a relationship between individual visual resolution and chromatic contrast. The implication is that some birds may have the sensory potential to perform “better” in certain visual tasks, but not necessarily in both resolution and contrast simultaneously. Overall, our findings (a) highlight the need to consider multiple individuals when characterizing sensory traits of a species, and (b) provide some mechanistic basis for between-individual variation in different behaviors (i.e., animal personalities) and for testing the predictions of several widely accepted hypotheses (e.g., honest signaling). PMID:25372039

  6. Accurate chromatic control and color rendering optimization in LED lighting systems using junction temperature feedback

    NASA Astrophysics Data System (ADS)

    Sisto, Marco Michele; Gauvin, Jonny

    2014-09-01

    Accurate color control of LED lighting systems is a challenging task: noticeable chromaticity shifts are commonly observed in mixed-color and phosphor converted LEDs due to intensity dimming. Furthermore, the emitted color varies with the LED temperature. We present a novel color control method for tri-chromatic and tetra-chromatic LEDs, which enable to set and maintain the LED emission at a target color, or combination of correlated color temperature (CCT) and intensity. The LED color point is maintained over variations in the LED junctions' temperatures and intensity dimming levels. The method does not require color feedback sensors, so to minimize system complexity and cost, but relies on estimation of the LED junctions' temperatures from the junction voltages. If operated with tetra-chromatic LEDs, the method allows meeting an additional optimization criterion: for example, the maximization of a color rendering metric like the Color Rendering Index (CRI) or the Color Quality Scale (CQS), thus providing a high quality and clarity of colors on the surface illuminated by the LED. We demonstrate the control of a RGBW LED at target D65 white point with CIELAB color difference metric triangle;a,bE < 1 for simultaneous variations of flux from approximately 30 lm to 100 lm and LED heat sink temperature from 25°C to 58°C. In the same conditions, we demonstrate a CCT error <1%. Furthermore, the method allows varying the LED CCT from 5500K to 8000K while maintaining luminance within 1% of target. Further work is ongoing to evaluate the stability of the method over LED aging.

  7. Hexavalent chromium is cytotoxic and genotoxic to hawksbill sea turtle cells.

    PubMed

    Wise, Sandra S; Xie, Hong; Fukuda, Tomokazu; Douglas Thompson, W; Wise, John Pierce

    2014-09-01

    Sea turtles are a charismatic and ancient ocean species and can serve as key indicators for ocean ecosystems, including coral reefs and sea grass beds as well as coastal beaches. Genotoxicity studies in the species are absent, limiting our understanding of the impact of environmental toxicants on sea turtles. Hexavalent chromium (Cr(VI)) is a ubiquitous environmental problem worldwide, and recent studies show it is a global marine pollutant of concern. Thus, we evaluated the cytotoxicity and genotoxicity of soluble and particulate Cr(VI) in hawksbill sea turtle cells. Particulate Cr(VI) was both cytotoxic and genotoxic to sea turtle cells. Concentrations of 0.1, 0.5, 1, and 5μg/cm(2) lead chromate induced 108, 79, 54, and 7% relative survival, respectively. Additionally, concentrations of 0, 0.1, 0.5, 1, and 5μg/cm(2) lead chromate induced damage in 4, 10, 15, 26, and 36% of cells and caused 4, 11, 17, 30, and 56 chromosome aberrations in 100 metaphases, respectively. For soluble Cr, concentrations of 0.25, 0.5, 1, 2.5, and 5μM sodium chromate induced 84, 69, 46, 25, and 3% relative survival, respectively. Sodium chromate induced 3, 9, 9, 14, 21, and 29% of metaphases with damage, and caused 3, 10, 10, 16, 26, and 39 damaged chromosomes in 100 metaphases at concentrations of 0, 0.25, 0.5, 1, 2.5, and 5μM sodium chromate, respectively. These data suggest that Cr(VI) may be a concern for hawksbill sea turtles and sea turtles in general. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Hexavalent Chromium Is Cytotoxic and Genotoxic to Hawksbill Sea Turtle Cells

    PubMed Central

    Wise, Sandra S.; Xie, Hong; Fukuda, Tomokazu; Thompson, W. Douglas; Wise, John Pierce

    2014-01-01

    Sea turtles are a charismatic and ancient ocean species and can serve as key indicators for ocean ecosystems, including coral reefs and sea grass beds as well as coastal beaches. Genotoxicity studies in the species are absent, limiting our understanding of the impact of environmental toxicants on sea turtles. Hexavalent chromium (Cr(VI)) is a ubiquitous environmental problem worldwide, and recent studies show it is a global marine pollutant of concern. Thus, we evaluated the cytotoxicity and genotoxicity of soluble and particulate Cr(VI) in hawksbill sea turtle cells. Particulate Cr(VI) was both cytotoxic and genotoxic to sea turtle cells. Concentrations of 0.1, 0.5, 1, and 5 μg/cm2 lead chromate induced 108, 79, 54, and 7 percent relative survival, respectively. Additionally, concentrations of 0, 0.1, 0.5, 1, and 5 μg/cm2 lead chromate induced damage in 4, 10, 15, 26, and 36 percent of cells and caused 4, 11, 17, 30, and 56 chromosome aberrations in 100 metaphases, respectively. For soluble Cr, concentrations of 0.25, 0.5, 1, 2.5, and 5 μM sodium chromate induced 84, 69, 46, 25, and 3 percent relative survival, respectively. Sodium chromate induced 3, 9, 9, 14, 21, and 29 percent of metaphases with damage, and caused 3, 10, 10, 16, 26, and 39 damaged chromosomes in 100 metaphases at concentrations of 0, 0.25, 0.5, 1, 2.5, and 5 μM sodium chromate, respectively. These data suggest that Cr(VI) may be a concern for hawksbill sea turtles and sea turtles in general. PMID:24952338

  9. Multidepth imaging by chromatic dispersion confocal microscopy

    NASA Astrophysics Data System (ADS)

    Olsovsky, Cory A.; Shelton, Ryan L.; Saldua, Meagan A.; Carrasco-Zevallos, Oscar; Applegate, Brian E.; Maitland, Kristen C.

    2012-03-01

    Confocal microscopy has shown potential as an imaging technique to detect precancer. Imaging cellular features throughout the depth of epithelial tissue may provide useful information for diagnosis. However, the current in vivo axial scanning techniques for confocal microscopy are cumbersome, time-consuming, and restrictive when attempting to reconstruct volumetric images acquired in breathing patients. Chromatic dispersion confocal microscopy (CDCM) exploits severe longitudinal chromatic aberration in the system to axially disperse light from a broadband source and, ultimately, spectrally encode high resolution images along the depth of the object. Hyperchromat lenses are designed to have severe and linear longitudinal chromatic aberration, but have not yet been used in confocal microscopy. We use a hyperchromat lens in a stage scanning confocal microscope to demonstrate the capability to simultaneously capture information at multiple depths without mechanical scanning. A photonic crystal fiber pumped with a 830nm wavelength Ti:Sapphire laser was used as a supercontinuum source, and a spectrometer was used as the detector. The chromatic aberration and magnification in the system give a focal shift of 140μm after the objective lens and an axial resolution of 5.2-7.6μm over the wavelength range from 585nm to 830nm. A 400x400x140μm3 volume of pig cheek epithelium was imaged in a single X-Y scan. Nuclei can be seen at several depths within the epithelium. The capability of this technique to achieve simultaneous high resolution confocal imaging at multiple depths may reduce imaging time and motion artifacts and enable volumetric reconstruction of in vivo confocal images of the epithelium.

  10. Evidence for Non-Opponent Coding of Colour Information in Human Visual Cortex: Selective Loss of "Green" Sensitivity in a Subject with Damaged Ventral Occipito-Temporal Cortex.

    PubMed

    Rauscher, Franziska G; Plant, Gordon T; James-Galton, Merle; Barbur, John L

    2011-01-01

    Damage to ventral occipito-temporal extrastriate visual cortex leads to the syndrome of prosopagnosia often with coexisting cerebral achromatopsia. A patient with this syndrome resulting in a left upper homonymous quadrantanopia, prosopagnosia, and incomplete achromatopsia is described. Chromatic sensitivity was assessed at a number of locations in the intact visual field using a dynamic luminance contrast masking technique that isolates the use of colour signals. In normal subjects chromatic detection thresholds form an elliptical contour when plotted in the Commission Internationale d'Eclairage, (x-y), chromaticity diagram. Because the extraction of colour signals in early visual processing involves opponent mechanisms, subjects with Daltonism (congenital red/green loss of sensitivity) show symmetric increase in thresholds towards the long wavelength ("red") and middle wavelength ("green") regions of the spectrum locus. This is also the case with acquired loss of chromatic sensitivity as a result of retinal or optic nerve disease. Our patient's results were an exception to this rule. Whilst his chromatic sensitivity in the central region of the visual field was reduced symmetrically for both "red/green" and "yellow/blue" directions in colour space, the subject's lower left quadrant showed a marked asymmetry in "red/green" thresholds with the greatest loss of sensitivity towards the "green" region of the spectrum locus. This spatially localized asymmetric loss of "green" but not "red" sensitivity has not been reported previously in human vision. Such loss is consistent with selective damage of neural substrates in the visual cortex that process colour information, but are spectrally non-opponent.

  11. Technical Note: Gray tracking in medical color displays-A report of Task Group 196.

    PubMed

    Badano, Aldo; Wang, Joel; Boynton, Paul; Le Callet, Patrick; Cheng, Wei-Chung; Deroo, Danny; Flynn, Michael J; Matsui, Takashi; Penczek, John; Revie, Craig; Samei, Ehsan; Steven, Peter M; Swiderski, Stan; Van Hoey, Gert; Yamaguchi, Matsuhiro; Hasegawa, Mikio; Nagy, Balázs Vince

    2016-07-01

    The authors discuss measurement methods and instrumentation useful for the characterization of the gray tracking performance of medical color monitors for diagnostic applications. The authors define gray tracking as the variability in the chromaticity of the gray levels in a color monitor. The authors present data regarding the capability of color measurement instruments with respect to their abilities to measure a target white point corresponding to the CIE Standard Illuminant D65 at different luminance values within the grayscale palette of a medical display. The authors then discuss evidence of significant differences in performance among color measurement instruments currently available for medical physicists to perform calibrations and image quality checks for the consistent representation of color in medical displays. In addition, the authors introduce two metrics for quantifying grayscale chromaticity consistency of gray tracking. The authors' findings show that there is an order of magnitude difference in the accuracy of field and reference instruments. The gray tracking metrics quantify how close the grayscale chromaticity is to the chromaticity of the full white point (equal amounts of red, green, and blue at maximum level) or to consecutive levels (equal values for red, green, and blue), with a lower value representing an improved grayscale tracking performance. An illustrative example of how to calculate and report the gray tracking performance according to the Task Group definitions is provided. The authors' proposed methodology for characterizing the grayscale degradation in chromaticity for color monitors that can be used to establish standards and procedures aiding in the quality control testing of color displays and color measurement instrumentation.

  12. Functionalized granular activated carbon and surface complexation with chromates and bi-chromates in wastewater.

    PubMed

    Singha, Somdutta; Sarkar, Ujjaini; Luharuka, Pallavi

    2013-03-01

    Cr(VI) is present in the aqueous medium as chromate (CrO4(2-)) and bi-chromate (HCrO4(-)). Functionalized granular activated carbons (FACs) are used as adsorbents in the treatment of wastewaters containing hexavalent chromium. The FACs are prepared by chemical modifications of granular activated carbons (GACs) using functionalizing agents like HNO3, HCl and HF. The Brunauer, Emmett and Teller surface areas of FAC-HCl (693.5m(2)/g), FAC-HNO3 (648.8m(2)/g) and FAC-HF (726.2m(2)/g) are comparable to the GAC (777.7m(2)/g). But, the adsorption capacity of each of the FAC-HNO3, FAC-HCl and FAC-HF is found to be higher than the GAC. The functional groups play an important role in the adsorption process and pH has practically no role in this specific case. The FACs have hydrophilic protonated external surfaces in particular, along with the functional surface sites capable to make complexes with the CrO4(2-) and HCrO4(-) present. Surface complex formation is maximized in the order FAC-HNO3>FAC-HF>FAC-HCl, in proportion to the total surface acidity. This is also confirmed by the well-known pseudo second-order kinetic model. Physi-sorption equilibrium isotherms are parameterized by using standard Freundlich and Langmuir models. Langmuir fits better. The formation of surface complexes with the functional groups and hexavalent chromium is also revealed in the images of field emission scanning electron micrograph; energy dispersive X-ray spectroscopy and Fourier transform infrared spectroscopy analysis after adsorption. The intra-particle diffusion is not the only rate-controlling factor. The Boyd's film diffusion model fits very well with R(2) as high as 98.1% for FAC-HNO3. This result demonstrates that the functionalization of the GAC by acid treatments would increase the diffusion rate, predominantly with a boundary layer diffusion effect. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. A Neural Model of Chromatic Induction in Uniform and Textured Images and Psychophysical Detection of Non-Opponent Chromatic Qualia

    ERIC Educational Resources Information Center

    Livitz, Gennady

    2011-01-01

    Color is a complex and rich perceptual phenomenon that relates physical properties of light to certain perceptual qualia associated with vision. Hering's opponent color theory, widely regarded as capturing the most fundamental aspects of color phenomenology, suggests that certain unique hues are mutually exclusive as components of a single color.…

  14. Mechanical Performance of Nail-Laminated Posts Manufactured from Reclaimed Chromated Copper Arsenate-Treated Decking Lumber

    Treesearch

    John J. Janowiak; Robert H. Falk; Brad A. Gething; John A. Tsirigotis

    2014-01-01

    This study determined the mechanical properties of nail-laminated (nail-lam) posts manufactured from reclaimed chromated copper arsenate (CCA)–treated decking lumber. Though CCA-treated lumber is no longer accepted for use in residential applications, it is permitted in agricultural and industrial applications where health and environmental impacts are deemed to be...

  15. Chromatic-aberration diagnostic based on a spectrally resolved lateral-shearing interferometer

    DOE PAGES

    Bahk, Seung -Whan; Dorrer, Christopher; Roides, Rick G.; ...

    2016-03-18

    Here, a simple diagnostic characterizing one-dimensional chromatic aberrations in a broadband beam is introduced. A Ronchi grating placed in front of a spectrometer entrance slit provides spectrally coupled spatial phase information. The radial-group delay of a refractive system and the pulse-front delay of a wedged glass plate have been characterized accurately in a demonstration experiment.

  16. Residual strength and stiffness of lumber from decommissioned chromated copper arsenate-treated southern pine utility poles

    Treesearch

    Cheng Piao; Leslie Groom

    2010-01-01

    The reusability of decommissioned treated wood is primarily dependent on the residual strength of the wood after service. Determining the residual strength can provide useful information for structural design and reuse of the decommissioned treated wood. This study evaluated the residual strength of decommissioned chromated copper arsenate–treated utility pole wood....

  17. THE APPLICATION OF IN SITU PERMEABLE REACTIVE (ZERO-VALENT IRON) BARRIER TECHNOLOGY FOR THE REMEDIATION OF CHROMATE-CONTAMINATED GROUNDWATER: A FIELD TEST

    EPA Science Inventory

    A small-scale field test was initiated in September 1994 to evaluate the in situ remediation of groundwater contaminated with chromate using a permeable reactive barrier composed of a mixture of zero-valent Fe, sand and aquifer sediment. The site used was an old chrome-plating f...

  18. A PROBABILISTIC ARSENIC EXPOSURE ASSESSMENT FOR CHILDREN WHO CONTACT CHROMATED COPPER ARSENATE ( CAA )-TREATED PLAYSETS AND DECKS: PART 2 SENSITIVITY AND UNCERTAINTY ANALYSIS

    EPA Science Inventory

    A probabilistic model (SHEDS-Wood) was developed to examine children's exposure and dose to chromated copper arsenate (CCA)-treated wood, as described in Part 1 of this two part paper. This Part 2 paper discusses sensitivity and uncertainty analyses conducted to assess the key m...

  19. Alternatives To Cadmium Plated Military Connectors

    DTIC Science & Technology

    2011-08-30

    from Feb 2011 Asets Defense conference  Amphenol Aerospace Operations report. 9/21/2011 10 Chromate finish  Hexavalent chrome was targeted by DOD...Fluorocarbon Zinc-Nickel Pure Dense Aluminum  Zinc-Nickel and Aluminum currently contain hexavalent chromate. Nickel-Fluorocarbon requires no...to lack of available drop in replacements, but this will change as alternatives become available.  Trivalent chrome and other non- chrome

  20. Electrocoat Process for Non-Chromate Primers in DoD Manufacturing

    DTIC Science & Technology

    2011-02-01

    requirements are uniquely  suited for aerospace  aluminum. ↑ O2 ↑ H2 Anode (+) Cathode (-) Deposited Film Alkaline  clean Rinse ElectrocoatSurface...Objectives ● Demonstration and validation of a novel, non‐chromated,  environmentally friendly,  electrodeposited  primer. ● The primers will be

  1. Study of chromatic adaptation using memory color matches, Part I: neutral illuminants.

    PubMed

    Smet, Kevin A G; Zhai, Qiyan; Luo, Ming R; Hanselaer, Peter

    2017-04-03

    Twelve corresponding color data sets have been obtained using the long-term memory colors of familiar objects as target stimuli. Data were collected for familiar objects with neutral, red, yellow, green and blue hues under 4 approximately neutral illumination conditions on or near the blackbody locus. The advantages of the memory color matching method are discussed in light of other more traditional asymmetric matching techniques. Results were compared to eight corresponding color data sets available in literature. The corresponding color data was used to test several linear (von Kries, RLAB, etc.) and nonlinear (Hunt & Nayatani) chromatic adaptation transforms (CAT). It was found that a simple two-step von Kries, whereby the degree of adaptation D is optimized to minimize the DEu'v' prediction errors, outperformed all other tested models for both memory color and literature corresponding color sets, whereby prediction errors were lower for the memory color sets. The predictive errors were substantially smaller than the standard uncertainty on the average observer and were comparable to what are considered just-noticeable-differences in the CIE u'v' chromaticity diagram, supporting the use of memory color based internal references to study chromatic adaptation mechanisms.

  2. Broadband achromatic optical metasurface devices.

    PubMed

    Wang, Shuming; Wu, Pin Chieh; Su, Vin-Cent; Lai, Yi-Chieh; Hung Chu, Cheng; Chen, Jia-Wern; Lu, Shen-Hung; Chen, Ji; Xu, Beibei; Kuan, Chieh-Hsiung; Li, Tao; Zhu, Shining; Tsai, Din Ping

    2017-08-04

    Among various flat optical devices, metasurfaces have presented their great ability in efficient manipulation of light fields and have been proposed for variety of devices with specific functionalities. However, due to the high phase dispersion of their building blocks, metasurfaces significantly suffer from large chromatic aberration. Here we propose a design principle to realize achromatic metasurface devices which successfully eliminate the chromatic aberration over a continuous wavelength region from 1200 to 1680 nm for circularly-polarized incidences in a reflection scheme. For this proof-of-concept, we demonstrate broadband achromatic metalenses (with the efficiency on the order of ∼12%) which are capable of focusing light with arbitrary wavelength at the same focal plane. A broadband achromatic gradient metasurface is also implemented, which is able to deflect wide-band light by the same angle. Through this approach, various flat achromatic devices that were previously impossible can be realized, which will allow innovation in full-color detection and imaging.Metasurfaces suffer from large chromatic aberration due to the high phase dispersion of their building blocks, limiting their applications. Here, Wang et al. design achromatic metasurface devices which eliminate the chromatic aberration over a continuous region from 1200 to 1680 nm in a reflection schleme.

  3. Integration of polarization and chromatic cues in the insect sky compass.

    PubMed

    el Jundi, Basil; Pfeiffer, Keram; Heinze, Stanley; Homberg, Uwe

    2014-06-01

    Animals relying on a celestial compass for spatial orientation may use the position of the sun, the chromatic or intensity gradient of the sky, the polarization pattern of the sky, or a combination of these cues as compass signals. Behavioral experiments in bees and ants, indeed, showed that direct sunlight and sky polarization play a role in sky compass orientation, but the relative importance of these cues are species-specific. Intracellular recordings from polarization-sensitive interneurons in the desert locust and monarch butterfly suggest that inputs from different eye regions, including polarized-light input through the dorsal rim area of the eye and chromatic/intensity gradient input from the main eye, are combined at the level of the medulla to create a robust compass signal. Conflicting input from the polarization and chromatic/intensity channel, resulting from eccentric receptive fields, is eliminated at the level of the anterior optic tubercle and central complex through internal compensation for changing solar elevations, which requires input from a circadian clock. Across several species, the central complex likely serves as an internal sky compass, combining E-vector information with other celestial cues. Descending neurons, likewise, respond both to zenithal polarization and to unpolarized cues in an azimuth-dependent way.

  4. Now you see me, now you don't: iridescence increases the efficacy of lizard chromatic signals

    NASA Astrophysics Data System (ADS)

    Pérez i de Lanuza, Guillem; Font, Enrique

    2014-10-01

    The selective forces imposed by primary receivers and unintended eavesdroppers of animal signals often act in opposite directions, constraining the development of conspicuous coloration. Because iridescent colours change their chromatic properties with viewer angle, iridescence offers a potential mechanism to relax this trade-off when the relevant observers involved in the evolution of signal design adopt different viewer geometries. We used reflectance spectrophotometry and visual modelling to test if the striking blue head coloration of males of the lizard Lacerta schreibeiri (1) is iridescent and (2) is more conspicuous when viewed from the perspective of conspecifics than from that of the main predators of adult L. schreibeiri (raptors). We demonstrate that the blue heads of L. schreiberi show angle-dependent changes in their chromatic properties. This variation allows the blue heads to be relatively conspicuous to conspecific viewers located in the same horizontal plane as the sender, while simultaneously being relatively cryptic to birds that see it from above. This study is the first to suggest the use of angle-dependent chromatic signals in lizards, and provides the first evidence of the adaptive function of iridescent coloration based on its detectability to different observers.

  5. Analyzing of chromaticity temperature of novel bulb composed of PDMS and phosphor

    NASA Astrophysics Data System (ADS)

    Novak, M.; Fajkus, M.; Jargus, J.; Bednarek, L.; Cubik, J.; Cvejn, D.; Vasinek, V.

    2017-10-01

    The authors of this article focused on the issue of measurement of the chromaticity temperature of proposed bulbs made from polydimethylsiloxane, depending on the temperature of proposed bulbs. The advantage of this solution is the immunity to electromagnetic interference (EMI) and the ability to use, for example in dangerous environments (such as mines, factories, etc.). For the realization of incandescent bulbs was used transparent two-component elastomer Sylgard 184. A mixture of polydimethylsiloxane (PDMS) and a curing agent in a defined ratio (10:1) and admixture with garnet phosphor YAG: Ce was cured in the temperature box at temperature 90°C +/- 3°C in the shape of the bulbs. All experiments were realized with eight different weight ratios of phosphor and Sylgard 184. Optical power (5 W) from a laser with a wavelength of 455 nm was fed to the proposed bulbs using the cylindrical waveguide of polydimethylsiloxane with a diameter of 5 mm. Chromaticity temperature was measured by two temperature sensors for 12h. The outcome of this study is the evaluation of the chromaticity temperature of output light depending on temperature variations of proposed bulbs due to the conversion of optical power into heat.

  6. Novel Perceptually Uniform Chromatic Space.

    PubMed

    da Fonseca, María; Samengo, Inés

    2018-06-01

    Chromatically perceptive observers are endowed with a sense of similarity between colors. For example, two shades of green that are only slightly discriminable are perceived as similar, whereas other pairs of colors, for example, blue and yellow, typically elicit markedly different sensations. The notion of similarity need not be shared by different observers. Dichromat and trichromat subjects perceive colors differently, and two dichromats (or two trichromats, for that matter) may judge chromatic differences inconsistently. Moreover, there is ample evidence that different animal species sense colors diversely. To capture the subjective metric of color perception, here we construct a notion of distance in color space based on the physiology of the retina, and is thereby individually tailored for different observers. By applying the Fisher metric to an analytical model of color representation, we construct a notion of distance that reproduces behavioral experiments of classical discrimination tasks. We then derive a coordinate transformation that defines a new chromatic space in which the Euclidean distance between any two colors is equal to the perceptual distance, as seen by one individual subject, endowed with an arbitrary number of color-sensitive photoreceptors, each with arbitrary absorption probability curves and appearing in arbitrary proportions.

  7. Suppression of mutants aberrant in light intensity responses of complementary chromatic adaptation.

    PubMed Central

    Casey, E S; Kehoe, D M; Grossman, A R

    1997-01-01

    Complementary chromatic adaptation is a process in which cyanobacteria alter the pigment protein (phycocyanin and phycoerythrin) composition of their light-harvesting complexes, the phycobilisomes, to help optimize the absorbance of prevalent wavelengths of light in the environment. Several classes of mutants that display aberrant complementary chromatic adaptation have been isolated. One of the mutant classes, designated "blue" or FdB, accumulates high levels of the blue chromoprotein phycocyanin in low-intensity green light, a condition that normally suppresses phycocyanin synthesis. We demonstrate here that the synthesis of the phycocyanin protein and mRNA in the FdB mutants can be suppressed by increasing the intensity of green light. Hence, these mutants have a decreased sensitivity to green light with respect to suppression of phycocyanin synthesis. Although we were unable to complement the blue mutants, we did isolate genes that could suppress the mutant phenotype. These genes, which have been identified previously, encode a histidine kinase sensor and response regulator protein that play key roles in controlling complementary chromatic adaptation. These findings are discussed with respect to the mechanism by which light quality and quantity control the biosynthesis of the phycobilisome. PMID:9226271

  8. Chromotomography for a rotating-prism instrument using backprojection, then filtering.

    PubMed

    Deming, Ross W

    2006-08-01

    A simple closed-form solution is derived for reconstructing a 3D spatial-chromatic image cube from a set of chromatically dispersed 2D image frames. The algorithm is tailored for a particular instrument in which the dispersion element is a matching set of mechanically rotated direct vision prisms positioned between a lens and a focal plane array. By using a linear operator formalism to derive the Tikhonov-regularized pseudoinverse operator, it is found that the unique minimum-norm solution is obtained by applying the adjoint operator, followed by 1D filtering with respect to the chromatic variable. Thus the filtering and backprojection (adjoint) steps are applied in reverse order relative to an existing method. Computational efficiency is provided by use of the fast Fourier transform in the filtering step.

  9. Replacement of corrosion protection chromate primers and paints used in cryogenic applications on the Space Shuttle with wire arc sprayed aluminum coatings

    NASA Technical Reports Server (NTRS)

    Daniel, R. L.; Sanders, H. L.; Zimmerman, F. R.

    1995-01-01

    With the advent of new environmental laws restricting volatile organic compounds and hexavalent chrome emissions, 'environmentally safe' thermal spray coatings are being developed to replace the traditional corrosion protection chromate primers. A wire arc sprayed aluminum coating is being developed for corrosion protection of low pressure liquid hydrogen carrying ducts on the Space Shuttle Main Engine. Currently, this hardware utilizes a chromate primer to provide protection against corrosion pitting and stress corrosion cracking induced by the cryogenic operating environment. The wire are sprayed aluminum coating has been found to have good potential to provide corrosion protection for flight hardware in cryogenic applications. The coating development, adhesion test, corrosion test and cryogenic flexibility test results will be presented.

  10. Competitive adsorption of boric acid and chromate onto alumina in aqueous solutions.

    PubMed

    Demetriou, A; Pashalidis, I

    2014-01-01

    The competitive adsorption of boric acid and chromate from aqueous solutions by alumina has been investigated by spectrophotometry at pH 8, ionic strength = 0.0, 0.1 and 1.0 M NaClO4, T = 22 ± 3 °C and under normal atmospheric conditions. The experimental data show that addition of excess boric acid in the system leads to the increase of Cr(VI) concentration in solution, indicating the replacement of adsorbed chromate by boron on the alumina surface. Data evaluation results in the determination of the competition reaction constant and the formation constant of the Cr(VI) surface complexes, which are logKCr(VI)-B(III) = -3.5 ± 0.2 and logβ*Cr = 7.6 ± 0.3, respectively.

  11. Spectrally balanced chromatic landing approach lighting system

    NASA Technical Reports Server (NTRS)

    Chase, W. D. (Inventor)

    1981-01-01

    Red warning lights delineate the runway approach with additional blue lights juxtaposed with the red lights such that the red lights are chromatically balanced. The red/blue point light sources result in the phenomenon that the red lights appear in front of the blue lights with about one and one-half times the diameter of the blue. To a pilot observing these lights along a glide path, those red lights directly below appear to be nearer than the blue lights. For those lights farther away seen in perspective at oblique angles, the red lights appear to be in a position closer to the pilot and hence appear to be above the corresponding blue lights. This produces a very pronounced three dimensional effect referred to as chromostereopsis which provides valuable visual cues to enable the pilot to perceive his actual position above the ground and the actual distance to the runway.

  12. Laboratory upwelled radiance and reflectance spectra of Kerr reservoir sediment waters

    NASA Technical Reports Server (NTRS)

    Witte, W. G.; Whitlock, C. H.; Morris, W. D.; Gurganus, E. A.

    1982-01-01

    Reflectance, chromaticity, and several other physical and chemical properties were measured for various water mixtures of bottom sediments taken from two sites at Kerr Reservoir, Virginia. Mixture concentrations ranged from 5 to 1000 ppm by weight of total suspended solids (TSS) in filtered deionized tap water. The two sets of radiance and reflectance spectra obtained were similar in shape and magnitude for comparable values of TSS. Upwelled reflectance was observed to be a nonlinear function of TSS with the degree of curvature a function of wavelength. Sediment from the downstream site contained a greater amount of particulate organic carbon than from the upstream site. No strong conclusions can be made regarding the effects of this difference on the radiance and reflectance spectra. Near-infrared wavelengths appear useful for measuring highly turbid water with concentrations up to 1000 ppm or more. Chromaticity characteristics do not appear useful for monitoring sediment loads above 150 ppm.

  13. Cancer mortality among workers exposed to zinc chromate paints.

    PubMed

    Dalager, N A; Mason, T J; Fraumeni, J F; Hoover, R; Payne, W W

    1980-01-01

    To evaluate the carcinogenicity of chromium compounds among user industries, the proportionate mortality experience of spray painters exposed to zinc chromate primer paints and electroplaters exposed to chromic acid in the aircraft maintenance industry was examined. Compared to the mortality patterns of U.S. white males, no excess of cancer was found in the 48 deaths among electroplaters. Analysis of the 202 deaths among spray painters revealed a significant excess of cancer, primarily of the respiratory tract. The relative increase of respiratory cancer showed a positive gradient with the length of estimated exposure time, and was confined to painters whose interval from first employment to death was at least 20 years. The findings consistent with occupational exposure to chromium compounds, previously shown to be carcinogenic in manufacturing processes, but the effect of other paint constituents, tobacco smoking, or methodologic limitations could not be discounted.

  14. Motion robust remote photoplethysmography in CIELab color space

    PubMed Central

    Yang, Yuting; Liu, Chenbin; Yu, Hui; Shao, Dangdang; Tsow, Francis; Tao, Nongjian

    2016-01-01

    Abstract. Remote photoplethysmography (rPPG) is attractive for tracking a subject’s physiological parameters without wearing a device. However, rPPG is known to be prone to body movement-induced artifacts, making it unreliable in realistic situations. Here we report a method to minimize the movement-induced artifacts. The method selects an optimal region of interest (ROI) automatically, prunes frames in which the ROI is not clearly captured (e.g., subject moves out of the view), and analyzes rPPG using an algorithm in CIELab color space, rather than the widely used RGB color space. We show that body movement primarily affects image intensity, rather than chromaticity, and separating chromaticity from intensity in CIELab color space thus helps achieve effective reduction of the movement-induced artifacts. We validate the method by performing a pilot study including 17 people with diverse skin tones. PMID:27812695

  15. Number of discernible object colors is a conundrum.

    PubMed

    Masaoka, Kenichiro; Berns, Roy S; Fairchild, Mark D; Moghareh Abed, Farhad

    2013-02-01

    Widely varying estimates of the number of discernible object colors have been made by using various methods over the past 100 years. To clarify the source of the discrepancies in the previous, inconsistent estimates, the number of discernible object colors is estimated over a wide range of color temperatures and illuminance levels using several chromatic adaptation models, color spaces, and color difference limens. Efficient and accurate models are used to compute optimal-color solids and count the number of discernible colors. A comprehensive simulation reveals limitations in the ability of current color appearance models to estimate the number of discernible colors even if the color solid is smaller than the optimal-color solid. The estimates depend on the color appearance model, color space, and color difference limen used. The fundamental problem lies in the von Kries-type chromatic adaptation transforms, which have an unknown effect on the ranking of the number of discernible colors at different color temperatures.

  16. In situ remediation process using divalent metal cations

    DOEpatents

    Brady, Patrick V.; Khandaker, Nadim R.; Krumhansl, James L.; Teter, David M.

    2004-12-14

    An in situ process for treating ambient solid materials (e.g., soils, aquifer solids, sludges) by adding one or more divalent metal cations to the ambient solid material. The added divalent metal cations, such as Cu.sup.2+ or Zn.sup.2+, combine with metal oxide/hydroxides (e.g., ferric oxide/hydroxide or aluminum oxide/hydroxide) already present in the ambient solid material to form an effective sorbent material having a large number of positively-charged surface complexes that binds and immobilizes anionic contaminant species (e.g., arsenic or chromate). Divalent metal cations can be added, for example, by injecting an aqueous solution of CuSO.sub.4 into an aquifer contaminated with arsenic or chromate. Also, sludges can be stabilized against leaching of anionic contaminants through the addition of divalent metal cations. Also, an inexpensive sorbent material can be easily formed by mixing divalent metal cations with soil that has been removed from the ground.

  17. A rain pixel recovery algorithm for videos with highly dynamic scenes.

    PubMed

    Jie Chen; Lap-Pui Chau

    2014-03-01

    Rain removal is a very useful and important technique in applications such as security surveillance and movie editing. Several rain removal algorithms have been proposed these years, where photometric, chromatic, and probabilistic properties of the rain have been exploited to detect and remove the rainy effect. Current methods generally work well with light rain and relatively static scenes, when dealing with heavier rainfall in dynamic scenes, these methods give very poor visual results. The proposed algorithm is based on motion segmentation of dynamic scene. After applying photometric and chromatic constraints for rain detection, rain removal filters are applied on pixels such that their dynamic property as well as motion occlusion clue are considered; both spatial and temporal informations are then adaptively exploited during rain pixel recovery. Results show that the proposed algorithm has a much better performance for rainy scenes with large motion than existing algorithms.

  18. 40 CFR 721.5288 - Chromate(2-), [3-hydroxy-4-[(2-hydroxy-1-naphthenyl)azo]-7-nitro-1-substituted][N-[7-hydroxy-8...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) TOXIC SUBSTANCES CONTROL ACT SIGNIFICANT NEW USES OF CHEMICAL SUBSTANCES Significant New Uses for Specific Chemical Substances § 721.5288 Chromate(2-), [3-hydroxy-4-[(2-hydroxy-1-naphthenyl)azo]-7-nitro-1-substituted][N-[7-hydroxy-8-[(2-hydroxy-5-nitrophenyl)azo]-1-substituted]-, salt (generic). (a) Chemical...

  19. Environmental concentrations of copper, chromium, and arsenic released from a chromated-copper-arsenate-(CCA-C-) treated wetland boardwalk

    Treesearch

    Stan T. Lebow; Daniel Foster

    2005-01-01

    A study was conducted to evaluate environmental accumulation and mobility of total copper, chromium, and arsenic adjacent to a chromated-copper-arsenate-(CCA-C-) treated wetland boardwalk. The study was considered a severe test because it included a large volume of treated wood in a site with high annual rainfall. Soil and sediment samples were collected before...

  20. Chrome-Free Paint Primer for Zn/Ni Plated High-Strength Steel (Briefing Charts)

    DTIC Science & Technology

    2014-11-19

    restrictions on use of chromates and Cd  Strontium chromate sunset in EU - REACH: 2017  LHE ZnNi replacing LHE Cd in military and commercial...Interaction Plot for Corrosion score Data Means 10001001010.10.01 99 95 90 80 70 60 50 40 30 20 10 5 1 Corrosion score P e rc e n t 1 2 Metal Base Lognormal

  1. Fractionation of heavy metals in liquefied chromated copper arsenate (CCA)-treated wood sludge using a modified BCR-sequential extraction procedure

    Treesearch

    Hui Pan; Chung-Yun Hse; Robert Gambrell; Todd F. Shupe

    2009-01-01

    Chromated copper arsenate (CCA)-treated wood was liquefied with polyethylene glycol/glycerin and sulfuric acid. After liquefaction, most CCA metals (98% As, 92% Cr, and 83% Cu) were removed from liquefied CCA-treated wood by precipitation with calcium hydroxide. The original CCA-treated wood and liquefied CCA-treated wood sludge were fractionated by a modified...

  2. Characterization of the propagation in photonic crystal fibers with the scalar-finite element method

    NASA Astrophysics Data System (ADS)

    Cherbi, L.; Bellalia, A.; Bahloul, L.; Touzene, M.; Lamara, M.

    2012-04-01

    We are arrived in this work to apply the SC-FEM to PCF to determine the modal field distribution and other important characteristics as normalized frequency, numeric aperture and chromatic dispersion according to the optogeometric parameters of the fiber. We could vanish the chromatic dispersion in the PCF at many low wavelengths because of its large degree of liberty.

  3. Ultraviolet Curable Powder Coatings With Robotic Curing for Aerospace Applications

    DTIC Science & Technology

    2011-02-01

    Problem: DoD spends millions of dollars annually on solvent- based coatings Hexavalent chrome primer use still very widespread Many topcoats contain...cure functionality can be added Various advanced non- chrome corrosion inhibitors DISTRIBUTION A. Approved for public release; distribution...chromate), Alodine 8800 (sol-gel) and Alodine 5200 (Zr chemistry) Fair to poor results over Alodine 1200S (chromate), and Alodine 5900 (tri- chrome

  4. Effect of simulated rainfall and weathering on release of preservative elements from CCA treated wood

    Treesearch

    Stan Lebow; R. Sam Williams; Patricia Lebow

    2003-01-01

    The release of arsenic from wood pressure-treated with chromated copper arsenate (CCA) can be decreased by application of wood finishes, but little is known about the types of finishes that are best suited for this purpose. This study evaluated the effects of finish water repellent content and ultraviolet (UV) radiation on the release of arsenic, copper, and chromium...

  5. Pretreatment of Cr(VI)-amended soil with chromate-reducing rhizobacteria decreases plant toxicity and increases the yield of Pisum sativum.

    PubMed

    Soni, Sumit K; Singh, Rakshapal; Singh, Mangal; Awasthi, Ashutosh; Wasnik, Kundan; Kalra, Alok

    2014-05-01

    Pot culture experiments were performed under controlled greenhouse conditions to investigate whether four Cr(VI)-reducing bacterial strains (SUCR44, SUCR140, SUCR186, and SUCR188) were able to decrease Cr toxicity to Pisum sativum plants in artificially Cr(VI)-contaminated soil. The effect of pretreatment of soil with chromate-reducing bacteria on plant growth, chromate uptake, bioaccumulation, nodulation, and population of Rhizobium was found to be directly influenced by the time interval between bacterial treatment and seed sowing. Pretreatment of soil with SUCR140 (Microbacterium sp.) 15 days before sowing (T+15) showed a maximum increase in growth and biomass in terms of root length (93 %), plant height (94 %), dry root biomass (99 %), and dry shoot biomass (99 %). Coinoculation of Rhizobium with SUCR140 further improved the aforementioned parameter. Compared with the control, coinoculation of SUCR140+R showed a 117, 116, 136, and 128 % increase, respectively, in root length, plant height, dry root biomass, and dry shoot biomass. The bioavailability of Cr(VI) decreased significantly in soil (61 %) and in uptake (36 %) in SUCR140-treated plants; the effects of Rhizobium, however, either alone or in the presence of SUCR140, were not significant. The populations of Rhizobium (126 %) in soil and nodulation (146 %) in P. sativum improved in the presence of SUCR140 resulting in greater nitrogen (54 %) concentration in the plants. This study shows the usefulness of efficient Cr(VI)-reducing bacterial strain SUCR140 in improving yields probably through decreased Cr toxicity and improved symbiotic relationship of the plants with Rhizobium. Further decrease in the translocation of Cr(VI) through improved nodulation by Rhizobium in the presence of efficient Cr-reducing bacterial strains could also decrease the accumulation of Cr in shoots.

  6. Recirculating linacs for a neutrino factory - Arc optics design and optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alex Bogacz; Valeri Lebedev

    2001-10-21

    A conceptual lattice design for a muon accelerator based on recirculating linacs (Nucl. Instr. and Meth. A 472 (2001) 499, these proceedings) is presented here. The challenge of accelerating and transporting a large phase space of short-lived muons is answered here by presenting a proof-of-principle lattice design for a recirculating linac accelerator. It is the centerpiece of a chain of accelerators consisting of a 3GeV linac and two consecutive recirculating linear accelerators, which facilitates acceleration starting after ionization cooling at 190MeV/c and proceeding to 50GeV. Beam transport issues for large-momentum-spread beams are accommodated by appropriate lattice design choices. The resultingmore » arc optics is further optimized with a sextupole correction to suppress chromatic effects contributing to the emittance dilution. The presented proof-of-principle design of the arc optics with horizontal separation of multi-pass beams can be extended to all passes in both recirculating linacs.« less

  7. Recirculating linacs for a neutrino factory - Arc optics design and optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valeri Lebedev; S. Bogacz

    2001-10-25

    A conceptual lattice design for a muon accelerator based on recirculating linacs (Nucl. Instr. and Meth. A 472 (2001) 499, these proceedings) is presented here. The challenge of accelerating and transporting a large phase space of short-lived muons is answered here by presenting a proof-of-principle lattice design for a recirculating linac accelerator. It is the centerpiece of a chain of accelerators consisting of a 3 GeV linac and two consecutive recirculating linear accelerators, which facilitates acceleration starting after ionization cooling at 190 MeV/c and proceeding to 50 GeV. Beam transport issues for large-momentum-spread beams are accommodated by appropriate lattice designmore » choices. The resulting arc optics is further optimized with a sextupole correction to suppress chromatic effects contributing to the emittance dilution. The presented proof-of-principle design of the arc optics with horizontal separation of multi-pass beams can be extended to all passes in both recirculating linacs.« less

  8. The color expression of copigmentation between malvidin-3-O-glucoside and three phenolic aldehydes in model solutions: The effects of pH and molar ratio.

    PubMed

    Zhang, Bo; He, Fei; Zhou, Pan-Pan; Liu, Yue; Duan, Chang-Qing

    2016-05-15

    Copigmentation was investigated in model solutions between the anthocyanin malvidin-3-O-glucoside and three phenolic aldehydes (vanillic, syringic and coniferyl aldehydes) as a function of the pH and the pigment/copigment molar ratio. Tristimulus colorimetry was applied to evaluate the chromatic variations induced by copigmentation process. The results indicated that the greatest magnitude of copigmentation was obtained at pH 3.0 and molar ratio of 1:100, being significantly higher with coniferyl aldehyde, followed by syringic and vanillic aldehydes. The equilibrium constant (K) and Gibbs free energies (ΔG°) determined here show a spontaneous exothermic reaction. Theoretical calculations (ΔGbinding, ΔE) specified the relative arrangement of the pigment and copigment molecules within the complexes. In addition, an atoms in molecules (AIM) analysis was used to explore the main driving forces contributing to the formation of copigmentation complexes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Analysis of retinal function using chromatic pupillography in retinitis pigmentosa and the relationship to electrically evoked phosphene thresholds.

    PubMed

    Kelbsch, Carina; Maeda, Fumiatsu; Lisowska, Jolanta; Lisowski, Lukasz; Strasser, Torsten; Stingl, Krunoslav; Wilhelm, Barbara; Wilhelm, Helmut; Peters, Tobias

    2017-06-01

    To analyse pupil responses to specific chromatic stimuli in patients with advanced retinitis pigmentosa (RP) to ascertain whether chromatic pupillography can be used as an objective marker for residual retinal function. To examine correlations between parameters of the pupil response and the perception threshold of electrically evoked phosphenes. Chromatic pupillography was performed in 40 patients with advanced RP (visual acuity < 0.02 or visual field ≤5°, non-recordable ERGs) and 40 age-matched healthy subjects. Pupil responses to full-field red (605 nm) and blue (420 nm) stimuli of 28 lx corneal illumination were recorded and analysed for two stimulus durations (1 and 4 seconds). The perception threshold of phosphenes to transcorneal electrostimulation was ascertained and correlated to the pupil responses and visual acuity. Patients with RP showed significantly reduced pupil responses to red and blue stimuli compared with the controls. With red stimuli, pupillary escape could be observed; blue stimuli resulted in a well-preserved postillumination pupil response. Phosphene thresholds were significantly increased in patients with RP and correlated with the parameters of the pupil response if all subjects were considered. Within the RP group alone, this relationship was less pronounced and statistically not significant. Chromatic pupillography demonstrated a significant decrease in outer retinal photoreceptor responses but a persisting and disinhibited intrinsic photosensitive retinal ganglion cell function in advanced RP. These phenomena may be useful as an objective marker for the efficacy of any interventional treatment for hereditary retinal diseases as well as for the selection of suitable patients for an electronic retinal implant. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Longitudinal chromatic aberration and emmetropization: results from the chicken eye.

    PubMed Central

    Rohrer, B; Schaeffel, F; Zrenner, E

    1992-01-01

    1. Due to the chromatic dispersion of the ocular media, the focal length of the optics of the eye is about 3 diopters longer for red light than for blue light. Because emmetropization in the chicken (Gallus domesticus) does not require colour cues and operates properly in monochromatic light, one can, therefore, expect that chickens raised in red light become more myopic (with longer eyes) than chicks raised in short wavelength light. Prior to conducting this experiment, we matched the brightness of both light conditions by means of flicker electroretinograms such that equiluminance was obtained for the chickens. 2. Unexpectedly, refractive development was not different from controls in white light for either red or near-ultraviolet light. 3. We tested whether the visual mechanisms guiding refractive development were still sensitive to defocus under both illuminations by treating the chicks with spectacle lenses. 4. Similar to a previous experiment in white light, the growth of the eye in red light also changed such that it compensated for the imposed defocus. It failed to do so, however, in near-ultraviolet light. 5. A histological analysis of the sampling intervals for the ultraviolet receptor system revealed that its spatial resolving power was too low to detect the defocus imposed by the lenses, whereas the long wavelength receptors provided sufficiently good visual acuity. 6. The results show that, during emmetropization, the chicken eye elegantly bypasses the problem of multiple chromatic focal planes by having a low sensitivity to defocus in the blue end of the spectrum. Because the chromatic dispersion function is steep in the blue range but flat at the red end of the spectrum, the remaining chromatic defocus in the spectral range of high visual acuity is low and may match the depth of field of the eye. PMID:1522513

  11. [A Method for Selecting Self-Adoptive Chromaticity of the Projected Markers].

    PubMed

    Zhao, Shou-bo; Zhang, Fu-min; Qu, Xing-hua; Zheng, Shi-wei; Chen, Zhe

    2015-04-01

    The authors designed a self-adaptive projection system which is composed of color camera, projector and PC. In detail, digital micro-mirror device (DMD) as a spatial light modulator for the projector was introduced in the optical path to modulate the illuminant spectrum based on red, green and blue light emitting diodes (LED). However, the color visibility of active markers is affected by the screen which has unknown reflective spectrum as well. Here active markers are projected spot array. And chromaticity feature of markers is sometimes submerged in similar spectral screen. In order to enhance the color visibility of active markers relative to screen, a method for selecting self-adaptive chromaticity of the projected markers in 3D scanning metrology is described. Color camera with 3 channels limits the accuracy of device characterization. For achieving interconversion of device-independent color space and device-dependent color space, high-dimensional linear model of reflective spectrum was built. Prior training samples provide additional constraints to yield high-dimensional linear model with more than three degrees of freedom. Meanwhile, spectral power distribution of ambient light was estimated. Subsequently, markers' chromaticity in CIE color spaces was selected via maximization principle of Euclidean distance. The setting values of RGB were easily estimated via inverse transform. Finally, we implemented a typical experiment to show the performance of the proposed approach. An 24 Munsell Color Checker was used as projective screen. Color difference in the chromaticity coordinates between the active marker and the color patch was utilized to evaluate the color visibility of active markers relative to the screen. The result comparison between self-adaptive projection system and traditional diode-laser light projector was listed and discussed to highlight advantage of our proposed method.

  12. Evidence for Non-Opponent Coding of Colour Information in Human Visual Cortex: Selective Loss of “Green” Sensitivity in a Subject with Damaged Ventral Occipito-Temporal Cortex

    PubMed Central

    Rauscher, Franziska G.; Plant, Gordon T.; James-Galton, Merle; Barbur, John L.

    2011-01-01

    Damage to ventral occipito-temporal extrastriate visual cortex leads to the syndrome of prosopagnosia often with coexisting cerebral achromatopsia. A patient with this syndrome resulting in a left upper homonymous quadrantanopia, prosopagnosia, and incomplete achromatopsia is described. Chromatic sensitivity was assessed at a number of locations in the intact visual field using a dynamic luminance contrast masking technique that isolates the use of colour signals. In normal subjects chromatic detection thresholds form an elliptical contour when plotted in the Commission Internationale d’Eclairage, (x-y), chromaticity diagram. Because the extraction of colour signals in early visual processing involves opponent mechanisms, subjects with Daltonism (congenital red/green loss of sensitivity) show symmetric increase in thresholds towards the long wavelength (“red”) and middle wavelength (“green”) regions of the spectrum locus. This is also the case with acquired loss of chromatic sensitivity as a result of retinal or optic nerve disease. Our patient’s results were an exception to this rule. Whilst his chromatic sensitivity in the central region of the visual field was reduced symmetrically for both “red/green” and “yellow/blue” directions in colour space, the subject’s lower left quadrant showed a marked asymmetry in “red/green” thresholds with the greatest loss of sensitivity towards the “green” region of the spectrum locus. This spatially localized asymmetric loss of “green” but not “red” sensitivity has not been reported previously in human vision. Such loss is consistent with selective damage of neural substrates in the visual cortex that process colour information, but are spectrally non-opponent. PMID:27956924

  13. Student Attitudes Toward Instructional Variables in a Human Anatomy Class as Assessed by a Projective Technique.

    ERIC Educational Resources Information Center

    Allen, Ruth M.; And Others

    1980-01-01

    Explored the effectiveness of the self-initiated modular approach for learning a unit in a human gross anatomy course, and student preference of cadaver dissection versus cadaver prosection. A color scale, the Chromatic Differential Test (CDT), was used to assess general student attitude and preference. (CS)

  14. Chemical yields from low-temperature pyrolysis of CCA-treated wood

    Treesearch

    Qirong Fu; Dimitris Argyropolous; Lucian Lucia; David Tilotta; Stan Lebow

    2009-01-01

    Low-temperature pyrolysis offers a feasible option for wood-waste management and the recovery of a variety of useful chemicals. The effect of chromated copper arsenate (CCA) wood preservative on the yield and composition of various pyrolysis products was investigated in the present research. A novel quantitative 31P nuclear magnetic resonance (...

  15. Less-toxic corrosion inhibitors

    NASA Technical Reports Server (NTRS)

    Humphries, T. S.

    1981-01-01

    Combinations of borates, nitrates, phosphates, silicates, and sodium MBT protect aluminum from corrosion in fresh water. Most effective combinations contained sodium phosphate and were alkaline. These inhibitors replace toxic chromates which are subject to governmental restrictions, but must be used in larger quantities. Experimental exposure times varied from 1 to 14 months depending upon nature of submersion solution.

  16. Receptoral and postreceptoral visual processes in recovery from chromatic adaptation.

    PubMed Central

    Jameson, D; Hurvich, L M; Varner, F D

    1979-01-01

    The time course of recovery from chromatic adaptation in human vision was tracked by determining the wavelength of light that appears uniquely yellow (neither red nor green) both before and after exposure to yellowish green and yellowish red adapting lights. Recovery is complete within 5 min after steady light exposure. After exposure to the alternating repeated sequence 10-sec light/10-sec dark, the initial magnitude of the aftereffect is reduced but recovery is retarded. The results are interpreted in terms of two processes located at different levels in the hierarchical organization of the visual system. One is a change in the balance of cone receptor sensitivities; the second is a shift in the equilibrium baseline between opposite-signed responses of the red/green channel at the opponent-process neural level. The baseline-shift mechanism is effective in the condition in which repeated input signals originating at the receptors are of sufficient strength to activate the system effectively. Hence, this process is revealed in the alternating adaptation condition when the receptors undergo partial recovery after each light exposure, but receptor adaptation during continued steady light exposure effectively protects the subsequent neural systems from continued strong activation. PMID:288087

  17. Comparison of Chromatic Dispersion Compensation Method Efficiency for 10 Gbit/S RZ-OOK and NRZ-OOK Wdm-Pon Transmission Systems

    NASA Astrophysics Data System (ADS)

    Alsevska, A.; Dilendorfs, V.; Spolitis, S.; Bobrovs, Vj.

    2017-12-01

    In the paper, the authors compare efficiency of two physical dispersion compensation methods for single channel and 8-channel WDM fibre-optical transmission systems using return-to-zero (RZ) and non-return-to-zero (NRZ) line codes for operation within optical C-band frequencies by means of computer simulations. As one of the most important destructive effects in fibre optical transmission systems (FOTS) is chromatic dispersion (CD), it is very important to reduce its negative effect on a transmitted signal. Dispersion compensation methods that were implemented in the research were dispersion compensating fibre (DCF) and fibre Bragg grating (FBG). The main goal of the paper was to find out which dispersion compensation method (DCF or FBG) provided the highest performance increase for fibre-optical transmission system and provided the longest transmission distance after dispersion compensation was implemented at different locations in the fibre-optical line while RZ or NRZ line codes were used. In the paper the reference point of signal quality for all measurements, which were obtained at the receiver, was BER<10-12.

  18. High-speed demodulation of weak fiber Bragg gratings based on microwave photonics and chromatic dispersion

    NASA Astrophysics Data System (ADS)

    Zhou, Lei; Li, Zhengying; Xiang, Na; Bao, Xiaoyi

    2018-06-01

    A high speed quasi-distributed demodulation method based on the microwave photonics and the chromatic dispersion effect is designed and implemented for weak fiber Bragg gratings (FBGs). Due to the effect of dispersion compensation fiber (DCF), FBG wavelength shift leads to the change of the difference frequency signal at the mixer. With the way of crossing microwave sweep cycle, all wavelengths of cascade FBGs can be high speed obtained by measuring the frequencies change. Moreover, through the introduction of Chirp-Z and Hanning window algorithm, the analysis of difference frequency signal is achieved very well. By adopting the single-peak filter as a reference, the length disturbance of DCF caused by temperature can be also eliminated. Therefore, the accuracy of this novel method is greatly improved, and high speed demodulation of FBGs can easily realize. The feasibility and performance are experimentally demonstrated using 105 FBGs with 0.1% reflectivity, 1 m spatial interval. Results show that each grating can be distinguished well, and the demodulation rate is as high as 40 kHz, the accuracy is about 8 pm.

  19. Identification of different shapes, colors and sizes of standard oral dosage forms in diabetes type 2 patients-A pilot study.

    PubMed

    Stegemann, Sven; Riedl, Regina; Sourij, Harald

    2017-01-30

    The clear identification of drug products by the patients is essential for a safe and effective medication management. In order to understand the impact of shape, size and color on medication identification a study was performed in subjects with type 2 diabetes mellitus (T2D). Ten model drugs differentiated by shape, size and color were evaluated using a mixed method of medication schedule preparation by the participants followed by a semi-structured interview. Detection times were fastest for the large round tablet shape and the bi-chromatic forms. Larger size was easier to identify than the smaller sizes except for the bi-chromatic forms. The shape was the major source of errors, followed by the size and the color dimension. The results from this study suggests that color as a single dimension are perceived more effectively by subjects with T2D compared to shape and size, which requires a more demanding processing of three dimension and is dependent on the perspective. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Colour cues proved to be more informative for dogs than brightness.

    PubMed

    Kasparson, Anna A; Badridze, Jason; Maximov, Vadim V

    2013-09-07

    The results of early studies on colour vision in dogs led to the conclusion that chromatic cues are unimportant for dogs during their normal activities. Nevertheless, the canine retina possesses two cone types which provide at least the potential for colour vision. Recently, experiments controlling for the brightness information in visual stimuli demonstrated that dogs have the ability to perform chromatic discrimination. Here, we show that for eight previously untrained dogs colour proved to be more informative than brightness when choosing between visual stimuli differing both in brightness and chromaticity. Although brightness could have been used by the dogs in our experiments (unlike previous studies), it was not. Our results demonstrate that under natural photopic lighting conditions colour information may be predominant even for animals that possess only two spectral types of cone photoreceptors.

  1. Analytical approach to chromatic correction in the final focus system of circular colliders

    DOE PAGES

    Cai, Yunhai

    2016-11-28

    Here, a conventional final focus system in particle accelerators is systematically analyzed. We find simple relations between the parameters of two focus modules in the final telescope. Using the relations, we derive the chromatic Courant-Snyder parameters for the telescope. The parameters are scaled approximately according to (L*/βmore » $$*\\atop{y}$$)δ, where L* is the distance from the interaction point to the first quadrupole, β$$*\\atop{y}$$ the vertical beta function at the interaction point, and δ the relative momentum deviation. Most importantly, we show how to compensate its chromaticity order by order in δ by a traditional correction module flanked by an asymmetric pair of harmonic multipoles. The method enables a circular Higgs collider with 2% momentum aperture and illuminates a path forward to 4% in the future.« less

  2. Complete genome sequence of the chromate-reducing bacterium Thermoanaerobacter thermohydrosulfuricus strain BSB-33

    DOE PAGES

    Bhattacharya, Pamela; Barnebey, Adam; Zemla, Marcin; ...

    2015-10-05

    Thermoanaerobacter thermohydrosulfuricus BSB-33 is a thermophilic gram positive obligate anaerobe isolated from a hot spring in West Bengal, India. Unlike other T. thermohydrosulfuricus strains, BSB-33 is able to anaerobically reduce Fe(III) and Cr(VI) optimally at 60 °C. BSB-33 is the first Cr(VI) reducing T. thermohydrosulfuricus genome sequenced and of particular interest for bioremediation of environmental chromium contaminations. Here we discuss features of T. thermohydrosulfuricus BSB-33 and the unique genetic elements that may account for the peculiar metal reducing properties of this organism. The T. thermohydrosulfuricus BSB-33 genome comprises 2597606 bp encoding 2581 protein genes, 12 rRNA, 193 pseudogenes and hasmore » a G + C content of 34.20 %. Lastly, putative chromate reductases were identified by comparative analyses with other Thermoanaerobacter and chromate-reducing bacteria.« less

  3. Illumination estimation via thin-plate spline interpolation.

    PubMed

    Shi, Lilong; Xiong, Weihua; Funt, Brian

    2011-05-01

    Thin-plate spline interpolation is used to interpolate the chromaticity of the color of the incident scene illumination across a training set of images. Given the image of a scene under unknown illumination, the chromaticity of the scene illumination can be found from the interpolated function. The resulting illumination-estimation method can be used to provide color constancy under changing illumination conditions and automatic white balancing for digital cameras. A thin-plate spline interpolates over a nonuniformly sampled input space, which in this case is a training set of image thumbnails and associated illumination chromaticities. To reduce the size of the training set, incremental k medians are applied. Tests on real images demonstrate that the thin-plate spline method can estimate the color of the incident illumination quite accurately, and the proposed training set pruning significantly decreases the computation.

  4. FLIR Common Module Design Manual. Revision 1

    DTIC Science & Technology

    1978-03-01

    degrade off-axis. The afocal assem- bly is very critical to system performance and normally constitutes a signif- icant portion of the system...not significantly degrade the performance at 10 lp/mm because chromatic errors are about 1/2 of the diffraction error. The chromatic errors are... degradation , though only 3 percent, is unavoidable. It is caused by field curvature in the galilean afocal assembly. This field curvature is

  5. Non-chromate Passivation for LHE ZnNi

    DTIC Science & Technology

    2017-03-01

    control of coatings and processes. Development of an alternative methodology that is simple, repeatable, non -destructive, and capable of scanning across...FINAL REPORT Non -chromate Passivation for LHE ZnNi SERDP Project WP-2527 JANUARY 2017 Matt O’Keefe Missouri S&T...valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From

  6. Metal Whiskers: A Discussion of Risks and Mitigation

    DTIC Science & Technology

    2010-11-30

    efforts to investigate – Chromate conversion finishes DO NOT appear to stop whisker formation [4] S. Arnold, "Repressing the Growth of Tin Whiskers...November 30, 2010 Metal Whiskers 10 Examples of Metal Whiskers Zinc-Plated Steel Bus Rail with Yellow Chromate Conversion Finish Zinc whiskers grew...Metal Whiskers 11 Examples of Metal Whiskers Tin-Plated D-Sub Connector Shell Connector Advertised as “RoHS Compliant” November 30, 2010 Metal

  7. Mesenchymal Stem Cell-Based Therapy for Prostate Cancer

    DTIC Science & Technology

    2014-09-01

    method for incubating hbMSCs with radioactive sodium chromate (51CrO4). Sodium chromate is cell permeable, but following reduction to trivalent ... chromium ion intracellularly it becomes impermeable due to crosslinking to macromolecules. Chromium -labeled cells (1x106) were then injected IV into...animals bearing CWR22 xenografts. Whole tissues were excised at the respective time points and total chromium was measured using a gamma counter, which

  8. In Situ Bioremediation of Perchlorate in Vadose Zone Soil Using Gaseous Electron Donors

    DTIC Science & Technology

    2009-11-01

    National Aeronautics and Space Administration ND Non-detect NDMA N-Nitrosodimethylamine No. Number NO3- Nitrate OD Outside diameter O&M...Nitrite xv • Selenate • Arsenate • Chromate and dichromate (i.e., hexavalent chromium) • Uranylate • Pertechnetate • N-Nitrosodimethylamine ( NDMA ...Arsenate • Chromate and dichromate (i.e., hexavalent chromium) • Uranylate • Pertechnetate • N-Nitrosodimethylamine ( NDMA ) • Trichloroethene (TCE

  9. Multi-Chromatic Ultrashort Pulse Filamentation and Bulk Modification in Dielectrics

    DTIC Science & Technology

    2016-05-05

    multi -pulse fields 7 6 Filamentation and bulk modification by spatio-temporally chirped pulses 8 7 Quantum modeling of photoionization and nonlinear...pulses. (b) two co-propagating pulses of di↵erent frequencies. 4) Develop non-time-averaged multi -chromatic quantum -mechanical models of photoion- ization...very well with those of the extended multi -rate equation using the relaxation approximation, which is much faster. A continued collaboration to also

  10. Colors of the Daytime Overcast Sky

    DTIC Science & Technology

    2005-09-20

    sunlight) spectra beneath overcast skies reveal an unexpectedly wide gamut of pastel colors. Analyses of these spectra indicate that at visible wavelengths...care, however, we also were able to acquire some data in drizzle, light rain, and snow. What kinds of chromaticity gamuts do such overcasts produce...noteworthy in Fig. 1. First, its chromaticity gamut for clear daylight is much less than for its two stratus and stratocumu- lus overcasts. Using the

  11. Development of a Nonchromate Structural Adhesive Bond Primer

    DTIC Science & Technology

    2014-11-01

    with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE NOV 2014 2. REPORT TYPE 3. DATES...Prevent corrosion of base metal • Applied to porous anodized surface • Overcoated with non-inhibited epoxy adhesive • High adhesive bond strength...primers •Long-running surveillance of chromate-free alternatives by UTC companies shows weak corrosion inhibition • (A) strontium chromate

  12. V1 mechanisms underlying chromatic contrast detection

    PubMed Central

    Hass, Charles A.

    2013-01-01

    To elucidate the cortical mechanisms of color vision, we recorded from individual primary visual cortex (V1) neurons in macaque monkeys performing a chromatic detection task. Roughly 30% of the neurons that we encountered were unresponsive at the monkeys' psychophysical detection threshold (PT). The other 70% were responsive at threshold but on average, were slightly less sensitive than the monkey. For these neurons, the relationship between neurometric threshold (NT) and PT was consistent across the four isoluminant color directions tested. A corollary of this result is that NTs were roughly four times lower for stimuli that modulated the long- and middle-wavelength sensitive cones out of phase. Nearly one-half of the neurons that responded to chromatic stimuli at the monkeys' detection threshold also responded to high-contrast luminance modulations, suggesting a role for neurons that are jointly tuned to color and luminance in chromatic detection. Analysis of neuronal contrast-response functions and signal-to-noise ratios yielded no evidence for a special set of “cardinal color directions,” for which V1 neurons are particularly sensitive. We conclude that at detection threshold—as shown previously with high-contrast stimuli—V1 neurons are tuned for a diverse set of color directions and do not segregate naturally into red–green and blue–yellow categories. PMID:23446689

  13. Illumination discrimination in real and simulated scenes

    PubMed Central

    Radonjić, Ana; Pearce, Bradley; Aston, Stacey; Krieger, Avery; Dubin, Hilary; Cottaris, Nicolas P.; Brainard, David H.; Hurlbert, Anya C.

    2016-01-01

    Characterizing humans' ability to discriminate changes in illumination provides information about the visual system's representation of the distal stimulus. We have previously shown that humans are able to discriminate illumination changes and that sensitivity to such changes depends on their chromatic direction. Probing illumination discrimination further would be facilitated by the use of computer-graphics simulations, which would, in practice, enable a wider range of stimulus manipulations. There is no a priori guarantee, however, that results obtained with simulated scenes generalize to real illuminated scenes. To investigate this question, we measured illumination discrimination in real and simulated scenes that were well-matched in mean chromaticity and scene geometry. Illumination discrimination thresholds were essentially identical for the two stimulus types. As in our previous work, these thresholds varied with illumination change direction. We exploited the flexibility offered by the use of graphics simulations to investigate whether the differences across direction are preserved when the surfaces in the scene are varied. We show that varying the scene's surface ensemble in a manner that also changes mean scene chromaticity modulates the relative sensitivity to illumination changes along different chromatic directions. Thus, any characterization of sensitivity to changes in illumination must be defined relative to the set of surfaces in the scene. PMID:28558392

  14. Colour image compression by grey to colour conversion

    NASA Astrophysics Data System (ADS)

    Drew, Mark S.; Finlayson, Graham D.; Jindal, Abhilash

    2011-03-01

    Instead of de-correlating image luminance from chrominance, some use has been made of using the correlation between the luminance component of an image and its chromatic components, or the correlation between colour components, for colour image compression. In one approach, the Green colour channel was taken as a base, and the other colour channels or their DCT subbands were approximated as polynomial functions of the base inside image windows. This paper points out that we can do better if we introduce an addressing scheme into the image description such that similar colours are grouped together spatially. With a Luminance component base, we test several colour spaces and rearrangement schemes, including segmentation. and settle on a log-geometric-mean colour space. Along with PSNR versus bits-per-pixel, we found that spatially-keyed s-CIELAB colour error better identifies problem regions. Instead of segmentation, we found that rearranging on sorted chromatic components has almost equal performance and better compression. Here, we sort on each of the chromatic components and separately encode windows of each. The result consists of the original greyscale plane plus the polynomial coefficients of windows of rearranged chromatic values, which are then quantized. The simplicity of the method produces a fast and simple scheme for colour image and video compression, with excellent results.

  15. Transient VEP and psychophysical chromatic contrast thresholds in children and adults.

    PubMed

    Boon, Mei Ying; Suttle, Catherine M; Dain, Stephen J

    2007-07-01

    It has been found that humans are able to distinguish colours without luminance cues by about 2-4 months of age and that sensitivity to colour difference develops during childhood, reaching a peak around adolescence. This prolonged period of maturation is reflected by improvements in psychophysical threshold measures and by the VEP characteristics of morphology, latency and amplitude. An intra-individual comparison of VEP and psychophysical responses to isoluminant colour stimuli has not been made in children, however, and this was the aim of the present study. VEPs were recorded from 49 subjects, children (age range: 4.8-12.6 years) and adults (age range: 25.7-33.2 years). Psychophysical and VEP thresholds were both measured in 40 of those subjects. Nominally isoluminant chromatic (L-M) sinewave gratings were presented in onset-offset mode and identical stimuli were used for psychophysical and VEP recordings to allow comparison. In agreement with previous reports, morphology of the transient VEP in response to this stimulus differed considerably between children and adults. There was a significant difference between psychophysical and VEP thresholds in children, but not in adults. Our findings support and expand on previous work on maturation of the L-M chromatic pathway and indicate a larger discrepancy between VEP and psychophysical chromatic thresholds in children than in adults.

  16. Two decades of exposure assessment studies on chromate production waste in Jersey City, New Jersey—what we have learned about exposure characterization and its value to public health and remediation

    PubMed Central

    Stern, Alan H.; Gochfeld, Michael; Lioy, Paul J.

    2014-01-01

    During much of the twentieth century, Jersey City, New Jersey was the leading center of chromate production in the United States. Chromate production produced huge volumes of chromium ore-processing residue containing many parts per million of hexavalent chromium. Starting in the 1990s, we undertook a series of studies to identify exposed populations, sources and pathways of exposure and the effectiveness of remediation activities in Jersey City. These studies revealed the effectiveness and success of the remediation activities. The sequence of studies presented here, builds on the lessons learned from each preceding study and illustrates how these studies advanced the field of exposure science in important ways, including the use of household dust as a measure of exposure to contaminants originating in the outdoor environment; development of effective and reproducible dust sampling; use of household dust to track temporal changes in exposure; understanding of the spatial relationship between sources of passive outdoor particulate emissions and residential exposure; use of focused biomonitoring to assess exposure under conditions of large inter-individual variability; and utility of linking environmental monitoring and biomonitoring. For chromium, the studies have demonstrated the use of Cr+6-specific analytical methods for measuring low concentrations of Cr+6 in household dust and understanding of the occurrence of Cr+6 in the background residential environment. We strongly recommend that environmental and public health agencies evaluate sites for their potential for off-site exposure and apply these tools in cases with significant potential as appropriate. This approach is especially important when contamination is widespread and/or a large population is potentially exposed. In such cases, these tools should be used to identify, characterize and then reduce the exposure to the off-site as well as on-site population. Importantly, these tools can be used in a demonstrable and quantifiable manner to provide both clarity and closure to concerned stakeholders. PMID:23131713

  17. Cone signals for spectacle-lens compensation: differential responses to short and long wavelengths.

    PubMed

    Rucker, Frances J; Wallman, Josh

    2008-09-01

    Chick eyes compensate for defocus imposed by spectacle lenses by making compensatory changes in eye length and choroidal thickness, a laboratory model of emmetropization. To investigate the roles of longitudinal chromatic aberration and of chromatic mechanisms in emmetropization, we examined the participation of different cone classes, and we compared the efficacy of lens compensation under monochromatic illumination with that under white light of the same illuminance to the chick eye. Chicks wore positive or negative 6D or 8D lenses on one eye for 3 days, under either blue (460 nm) or red (620 nm) light at 0.67 lux or under white light at 0.67 or 0.2 lux (all measures are corrected for chick photopic sensitivity). The illumination conditions were chosen to differentially stimulate either the short-wavelength and ultraviolet cones or the long-wavelength and double cones. Measurements are expressed as the relative change: the inter-ocular difference in the amount of change over the 3 days of lens wear. We find that under this low illumination the two components of lens compensation were differentially affected by the monochromatic illumination: in blue light lens compensation was mainly due to changes in eye length, whereas in red light lens compensation was mainly due to changes in choroidal thickness. In general, white light produced better lens compensation than monochromatic illumination. NEGATIVE LENSES: Under white light negative lenses caused an increase in eye length (60 microm) together with a decrease in choroidal thickness (-51 microm) relative to the fellow eye. Under blue light, although there was an increase in eye length (32 microm), there was no change in choroidal thickness (5 microm). In contrast, under red light there was a decrease in choroidal thickness (-62 microm) but no increase in eye length (8 microm). Relative ocular elongation was the same in white and monochromatic light. POSITIVE LENSES: Under white light positive lenses caused a decrease in eye length (-142 microm) together with an increase in choroidal thickness (68 microm) relative to the fellow eye. Under blue light, there was a decrease in eye length (-64 microm), but no change in choroidal thickness (2 microm). In contrast, under red light there was an increase (90 microm) in choroidal thickness but less of a decrease (-36 microm) in eye length. Lens compensation by inhibition of ocular elongation was less effective under monochromatic illumination than under white light (white v red: p=0.003; white v blue p=.014). The differential effects of red and blue light on the choroidal and ocular length compensatory responses suggest that they are driven by different proportions of the cone-types, implying that, although chromatic contrast is not essential for lens compensation and presumably for emmetropization as well, the retinal substrates exist for utilizing chromatic contrast in these compensatory responses. The generally better lens compensation in white than monochromatic illumination suggests that longitudinal chromatic aberration may be used in lens compensation.

  18. Modeling corrosion inhibition efficacy of small organic molecules as non-toxic chromate alternatives using comparative molecular surface analysis (CoMSA).

    PubMed

    Fernandez, Michael; Breedon, Michael; Cole, Ivan S; Barnard, Amanda S

    2016-10-01

    Traditionally many structural alloys are protected by primer coatings loaded with corrosion inhibiting additives. Strontium Chromate (or other chromates) have been shown to be extremely effectively inhibitors, and find extensive use in protective primer formulations. Unfortunately, hexavalent chromium which imbues these coatings with their corrosion inhibiting properties is also highly toxic, and their use is being increasingly restricted by legislation. In this work we explore a novel tridimensional Quantitative-Structure Property Relationship (3D-QSPR) approach, comparative molecular surface analysis (CoMSA), which was developed to recognize "high-performing" corrosion inhibitor candidates from the distributions of electronegativity, polarizability and van der Waals volume on the molecular surfaces of 28 small organic molecules. Multivariate statistical analysis identified five prototypes molecules, which are capable of explaining 71% of the variance within the inhibitor data set; whilst a further five molecules were also identified as archetypes, describing 75% of data variance. All active corrosion inhibitors, at a 80% threshold, were successfully recognized by the CoMSA model with adequate specificity and precision higher than 70% and 60%, respectively. The model was also capable of identifying structural patterns, that revealed reasonable starting points for where structural changes may augment corrosion inhibition efficacy. The presented methodology can be applied to other functional molecules and extended to cover structure-activity studies in a diverse range of areas such as drug design and novel material discovery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Chromate and phosphate inhibited each other's uptake and translocation in arsenic hyperaccumulator Pteris vittata L.

    PubMed

    de Oliveira, Letúzia M; Lessl, Jason T; Gress, Julia; Tisarum, Rujira; Guilherme, Luiz R G; Ma, Lena Q

    2015-02-01

    We investigated the effects of chromate (CrVI) and phosphate (P) on their uptake and translocation in As-hyperaccumulator Pteris vittata (PV). Plants were exposed to 1) 0.10 mM CrVI and 0, 0.25, 1.25, or 2.50 mM P or 2) 0.25 mM P and 0, 0.50, 2.5 or 5.0 mM CrVI for 24 h in hydroponics. PV accumulated 2919 mg/kg Cr in the roots at CrVI₀.₁₀, and 5100 and 3500 mg/kg P in the fronds and roots at P₀.₂₅. When co-present, CrVI and P inhibited each other's uptake in PV. Increasing P concentrations reduced Cr root concentrations by 62-82% whereas increasing CrVI concentrations reduced frond P concentrations by 52-59% but increased root P concentrations by 11-15%. Chromate reduced P transport, with more P being accumulated in PV roots. Though CrVI was supplied, 64-78% and 92-93% CrIII were in PV fronds and roots. Based on X-ray diffraction, Cr₂O₃ was detected in the roots confirming CrVI reduction to CrIII by PV. In short, CrVI and P inhibited each other in uptake and translocation by PV, and CrVI reduction to CrIII in PV roots served as its detoxification mechanism. The finding helps to understand the interactions of P and Cr during their uptake in PV. Published by Elsevier Ltd.

  20. Less-Toxic Coatings for Inhibiting Corrosion of Aluminum

    NASA Technical Reports Server (NTRS)

    Minevski, Zoran; Clarke, Eric; Eylem, Cahit; Maxey, Jason; Nelson, Carl

    2003-01-01

    Two recently invented families of conversion- coating processes have been found to be effective in reducing or preventing corrosion of aluminum alloys. These processes offer less-toxic alternatives to prior conversion-coating processes that are highly effective but have fallen out of favor because they generate chromate wastes, which are toxic and carcinogenic. Specimens subjected to these processes were found to perform well in standard salt-fog corrosion tests.

Top