Sample records for chromatographic rp-hplc method

  1. High Performance Liquid Chromatographic Analysis of Phytoplankton Pigments Using a C16-Amide Column

    EPA Science Inventory

    A reverse-phase high performance liquid chromatographic (RP-HPLC) method was developed to analyze in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a RP-C16-Amide column and a ternary gradient system consistin...

  2. Development and Validation of a Simultaneous RP-HPLCUV/DAD Method for Determination of Polyphenols in Gels Containing S. terebinthifolius Raddi (Anacardiaceae)

    PubMed Central

    Carvalho, Melina G.; Aragão, Cícero F. S; Raffin, Fernanda N.; de L. Moura, Túlio F. A.

    2017-01-01

    Topical gels containing extracts of Schinus terebinthifolius have been used to treat bacterial vaginosis. It has been reported that this species has antimicrobial, anti-inflammatory and anti-ulcerogenic properties, which can be attributed to the presence of phenolic compounds. In this work, a sensitive and selective reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols that could be present in S. terebinthifolius was developed. The method was shown to be accurate and precise. Peak purity and similarity index both exceeded 0.99. Calibration curves were linear over the concentration range studied, with correlation coefficients between 0.9931 and 0.9974. This method was used to determine the polyphenol content of a hydroalcoholic extract and pharmacy-compounded vaginal gel. Although the method is useful to assess the 6 phenolic compounds, some compounds could not be detected in the products. SUMMARY A sensitive, selective, accurate and precise reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols in S. terebinthifolius Raddi Abbreviations used: RP-HPLC-UV/DAD: Reverse Phase High Performance Liquid Chromatograph with Ultraviolet and Diode Array Detector, HPLC: High Performance Liquid Chromatograph, HPLC-UV: High Performance Liquid Chromatograph with Ultraviolet Detector, ANVISA: Brazilian National Health Surveillance Agency, LOD: Limit of detection, LOQ: Limit of quantitation PMID:28539726

  3. A NEW HPLC METHOD FOR SEPARATION OF PHYTOPLANKTON PIGMENTS IN NATURAL SAMPLES

    EPA Science Inventory

    A new high-performance liquid chromatographic (HPLC) method was developed to analyze, in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a reverse-phase amide C16 (RP-amide C16) column and an elution gradient o...

  4. Isolation, Characterization, and RP-HPLC Estimation of P-Coumaric Acid from Methanolic Extract of Durva Grass (Cynodon dactylon Linn.) (Pers.)

    PubMed Central

    Karthikeyan, Ramadoss; Devadasu, Chapala; Srinivasa Babu, Puttagunta

    2015-01-01

    P-coumaric acid is a nonflavonoid phenolic acid and is a major constituent of the species Cynodon dactylon Linn. (Pers.). In this study isolation of P-coumaric acid was achieved by preparative TLC and the compound thus isolated was characterised by UV, mass, and H1 NMR spectral analysis. An isocratic RP-HPLC method was developed for the estimation of P-coumaric acid from methanolic extracts of durva grass. The chromatographic separations were achieved by RP-C18 column (250 mm × 4.6 mm, 5 μ), Shimadzu LC-20AT Prominence liquid chromatograph, and a mobile phase composed of water : methanol : glacial acetic acid (65 : 34 : 1 v/v). The flow rate was 1.0 mL/min and the analyses of column effluents were performed using UV-visible detector at 310 nm. Retention time of P-coumaric acid was found to be 6.617 min. This method has obeyed linearity over the concentration range of 2–10 μg/mL and the regression coefficient obtained from linearity plot for P-coumaric acid was found to be 0.999. RP-HPLC method was validated in pursuance of ICH guidelines. PMID:25788944

  5. Prediction of soil organic carbon partition coefficients by soil column liquid chromatography.

    PubMed

    Guo, Rongbo; Liang, Xinmiao; Chen, Jiping; Wu, Wenzhong; Zhang, Qing; Martens, Dieter; Kettrup, Antonius

    2004-04-30

    To avoid the limitation of the widely used prediction methods of soil organic carbon partition coefficients (KOC) from hydrophobic parameters, e.g., the n-octanol/water partition coefficients (KOW) and the reversed phase high performance liquid chromatographic (RP-HPLC) retention factors, the soil column liquid chromatographic (SCLC) method was developed for KOC prediction. The real soils were used as the packing materials of RP-HPLC columns, and the correlations between the retention factors of organic compounds on soil columns (ksoil) and KOC measured by batch equilibrium method were studied. Good correlations were achieved between ksoil and KOC for three types of soils with different properties. All the square of the correlation coefficients (R2) of the linear regression between log ksoil and log KOC were higher than 0.89 with standard deviations of less than 0.21. In addition, the prediction of KOC from KOW and the RP-HPLC retention factors on cyanopropyl (CN) stationary phase (kCN) was comparatively evaluated for the three types of soils. The results show that the prediction of KOC from kCN and KOW is only applicable to some specific types of soils. The results obtained in the present study proved that the SCLC method is appropriate for the KOC prediction for different types of soils, however the applicability of using hydrophobic parameters to predict KOC largely depends on the properties of soil concerned.

  6. Determination of pterins in urine by HPLC with UV and fluorescent detection using different types of chromatographic stationary phases (HILIC, RP C8, RP C18).

    PubMed

    Kośliński, Piotr; Jarzemski, Piotr; Markuszewski, Michał J; Kaliszan, Roman

    2014-03-01

    Pterins are a class of potential cancer biomarkers. New methods involving hydrophilic interaction liquid chromatography (HILIC) and reversed phase (RP) high-performance liquid chromatography have been developed for analysis of eight pterin compounds: 6,7-dimethylpterin, pterin, 6-OH-methylpterin, biopterin, isoxanthopterin, neopterin, xanthopterin, and pterin-6-carboxylic acid. The effect of mobile phase composition, buffer type, pH and concentration on retention using HILIC, C8 and C18 RP stationary phases were examined. Separation of pterins on RP and HILIC stationary phase was performed and optimized. Eight pterins were successfully separated on HILIC Luna diol-bonded phases, Aquasil C18 RP column and LiChrospher C8 RP column. Determination and separation of the pterins from urine samples were performed on HILIC Luna and LiChrospher C8 RP columns which were chosen as the most appropriate ones. Finally, LiChrospher C8 RP column with fluorescence detection was selected for further validation of the method. The optimum chromatographic condition was mobile phase methanol (A)/phosphoric buffer pH 7, 10mM (B), isocratic elution 0-15min 5% A flow=0.5ml/min 15-17min. 5% A, flow=0.5-1ml/min the linearity (R(2)>0.997) and retention time repeatability (RSD%<1) were at satisfactory level. The precision of peak areas expressed as RSD in % was between 0.55 and 14. Pterins detection limits varied from 0.041ng/ml to 2.9ng/ml. Finally, HPLC method was used for the analysis of pterins in urine samples with two different oxidation procedures. Concentration levels of pterin compounds in bladder cancer patients and healthy subjects were compared. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulations.

    PubMed

    Mukherjee, Jayanti; Das, Ayan; Chakrabarty, Uday Sankar; Sahoo, Bijay Kumar; Dey, Goutam; Choudhury, Hira; Pal, Tapan Kumar

    2011-01-01

    This study describes development and subsequent validation of a reversed phase high performance liquid chromatographic (RP-HPLC) method for the estimation of nandrolone phenylpropionate, an anabolic steroid, in bulk drug, in conventional parenteral dosage formulation and in prepared nanoparticle dosage form. The chromatographic system consisted of a Luna Phenomenex, CN (250 mm x 4.6 mm, 5 microm) column, an isocratic mobile phase comprising 10 mM phosphate buffer and acetonitrile (50:50, v/v) and UV detection at 240 nm. Nandrolone phenylpropionate was eluted about 6.3 min with no interfering peaks of excipients used for the preparation of dosage forms. The method was linear over the range from 0.050 to 25 microg/mL in raw drug (r2 = 0.9994). The intra-day and inter-day precision values were in the range of 0.219-0.609% and 0.441-0.875%, respectively. Limits of detection and quantitation were 0.010 microg/mL and 0.050 microg/mL, respectively. The results were validated according to International Conference on Harmonization (ICH) guidelines in parenteral and prepared nanoparticle formulation. The validated HPLC method is simple, sensitive, precise, accurate and reproducible.

  8. Assessment of the chromatographic lipophilicity of eight cephalosporins on different stationary phases.

    PubMed

    Dąbrowska, Monika; Starek, Małgorzata; Komsta, Łukasz; Szafrański, Przemysław; Stasiewicz-Urban, Anna; Opoka, Włodzimierz

    2017-04-01

    The retention behaviors were investigated for a series of eight cephalosporins in thin-layer chromatography (TLC) using stationary phases of RP-2, RP-8, RP-18, NH 2 , DIOL, and CN chemically bonded silica gel. Additionally, various binary mobile phases (water/methanol and water/acetone) were used in different volume proportions. The retention behavior of the analyzed molecules was defined by R M0 constant. In addition, reversed phase high performance liquid chromatography (RP-HPLC) was performed in lipophilicity studies by using immobilized artificial membrane (IAM) stationary phase. Obtained chromatographic data (R M0 and logk' IAM ) were correlated with the lipophilicity, expressed as values of the log calculated (logP calc ) and experimental (logP exp(shake-flask) ) partition coefficient. Principal component analysis (PCA) was applied in order to obtain an overview of similarity or dissimilarity among the analyzed compounds. Hierarchical cluster analysis (HCA) was performed to compare the separation characteristics of the applied stationary phases. This study was undertaken to identify the best chromatographic system and chromatographic data processing method to enable the prediction of logP values. A comprehensive chromatographic investigation into the retention of the analyzed cephalosporins revealed a similar behavior on RP-18, RP-8 and CN stationary phases. The weak correlations obtained between experimental and certain computed lipophilicity indices revealed that R M0 and PC1/RM are relevant lipophilicity parameters and the RP-8, CN and RP-18 plates are appropriate stationary phases for lipophilicity investigation, whereas computational approaches still cannot fully replace experimentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. High-performance liquid chromatographic determination of the beta2-selective adrenergic agonist fenoterol in human plasma after fluorescence derivatization.

    PubMed

    Kramer, S; Blaschke, G

    2001-02-10

    A sensitive high-performance liquid chromatographic method has been developed for the determination of the beta2-selective adrenergic agonist fenoterol in human plasma. To improve the sensitivity of the method, fenoterol was derivatized with N-(chloroformyl)-carbazole prior to HPLC analysis yielding highly fluorescent derivatives. The assay involves protein precipitation with acetonitrile, liquid-liquid-extraction of fenoterol from plasma with isobutanol under alkaline conditions followed by derivatization with N-(chloroformyl)-carbazole. Reversed-phase liquid chromatographic determination of the fenoterol derivative was performed using a column-switching system consisting of a LiChrospher 100 RP 18 and a LiChrospher RP-Select B column with acetonitrile, methanol and water as mobile phase. The limit of quantitation in human plasma was 376 pg fenoterol/ml. The method was successfully applied for the assay of fenoterol in patient plasma.

  10. Synthesis, liquid chromatographic fractionation and partial characterization of polybrominated dibenzofuran congeners.

    PubMed

    Gallistl, Christoph; Vetter, Walter

    2016-04-15

    Polybrominated dibenzofurans (PBDFs) are a class of highly toxic environmental contaminants which comprises 135 structurally different congeners. While the gas chromatographic separation and analysis of the most polychlorinated dibenzofurans (PCDFs) are well-documented, comparably little data is currently available in the case of PBDFs. In this study dibenzofuran was brominated to give a mixture of ∼40 PBDFs with one to seven bromine atoms. This synthesis mixture was fractionated by both countercurrent chromatography (CCC) with the solvent system n-hexane/toluene/acetonitrile and non-aqueous reversed-phase high performance liquid chromatography (RP-HPLC) with acetonitrile as the mobile phase. All together 80 consecutive CCC fractions and 40 HPLC fractions were taken and analyzed for PBDFs by gas chromatography coupled to mass spectrometry (GC/MS). CCC and RP-HPLC offered orthogonal separation of the PBDF mixture. As a consequence, selected CCC fractions were further fractionated by RP-HPLC. In this way, eight PBDFs could be isolated and the structures of twelve PBDFs were elucidated by proton magnetic resonance spectroscopy ((1)H NMR). Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Major and Modified Nucleosides, RNA, and DNA

    NASA Astrophysics Data System (ADS)

    Gehrke, Charles W.; Kuo, Kenneth C.

    Most analytical chemists are well aware of the rapid rate of development of high-performance liquid chromatography (HPLC) over the past 5 years. A number of articles have been published in Analytical Chemistry on different topics in HPLC and many papers appear in the chromatographic journals. Some books also have been published covering this subject. HPLC has proved to be a very effective, broadly applicable chromatographic method for the separation and analysis of complex molecules in fields as diverse as biochemistry and environmental, pharmaceutical, medical, and polymer chemistry. HPLC is now having a major impact on the clinical and research aspects of medical biochemistry. Although the contributions of HPLC to other disciplines generally complements gas-liquid chromatography, this method is destined to play a much greater role in medical and biochemical research. This is because many of the biomolecules, owing to their molecular complexity and size, are thermally unstable or nonvolatile, preventing or complicating an analysis by GC. A major factor contributing to the powerful advances in biomedical liquid chromatography is the development of reversed-phase high-performance liquid chromatography (RP-HPLC) using n-alkyl and phenyl chemically bonded substrates.

  12. Influence of the Structure of Molecules of Derivatives of 1,2,4-Triazole and 1,2,4-Triazine on Chromatographic Retention Under Conditions of Reversed Phase HPLC

    NASA Astrophysics Data System (ADS)

    Karaseva, I. N.; Karasev, M. O.; Nechaeva, O. N.; Kurbatova, S. V.

    2018-07-01

    The dependence of the chromatographic retention of 1,2,4-triazine and 1,2,4-triazole derivatives from water-acetonitrile solutions over octadecyl silica on the structure of sorbate molecules is studied. The effect the physicochemical parameters and topology of heterocycle molecules have on the retention characteristics under RP HPLC conditions is analyzed.

  13. Purification and characterization of selenium-containing phycocyanin from selenium-enriched Spirulina platensis.

    PubMed

    Chen, Tianfeng; Wong, Yum-Shing; Zheng, Wenjie

    2006-11-01

    A fast protein liquid chromatographic method for purification of selenium-containing phycocyanin (Se-PC) from selenium-enriched Spirulina platensis was described in this study. The purification procedures involved fractionation by ammonium sulfate precipitation, DEAE-Sepharose ion-exchange chromatography and Sephacry S-300 size exclusion chromatography. The purity ratio (A620/A280) and the separation factor (A620/A655) of the purified Se-PC were 5.12 and 7.92, respectively. The Se concentration of purified Se-PC was 496.5 microg g(-1) protein, as determined by ICP-AES analysis. The purity of the Se-PC was further characterized by UV-VIS and fluorescence spectrometry, SDS-PAGE, RP-HPLC and gel filtration HPLC. The apparent molecular mass of the native Se-PC determined by gel filtration HPLC was 109 kDa, indicating that the protein existed as a trimer. SDS-PAGE of the purified Se-PC yielded two major bands corresponding to the alpha and beta subunits. A better separation of these two subunits was obtained by RP-HPLC. Identification of the alpha and beta subunits separated by SDS-PAGE and RP-HPLC was achieved by peptide mass fingerprinting (PMF) using MALDI-TOF-TOF mass spectrometry.

  14. Sorption of benzotriazoles under the conditions of RP HPLC

    NASA Astrophysics Data System (ADS)

    Dzhabieva, S. A.; Kurbatova, S. V.; Belousova, Z. P.

    2016-02-01

    The results of a chromatographic study of sorption of several benzotriazole derivatives on octadecyl silica gel were reported. The physicochemical and electronic parameters of benzotriazoles were calculated. The effect of the structure of analyte molecules and eluent composition on chromatographic retention of these substances was analyzed.

  15. Comparative studies on performance of CCC and preparative RP-HPLC in separation and purification of steroid saponins from Dioscorea zingiberensis C.H.Wright

    PubMed Central

    Zhang, Xinxin; Liang, Jinru; Zhang, Yongmin; Liu, Jianli; Sun, Wenji; Ito, Yoichiro

    2015-01-01

    Steroid saponins from Dioscorea zingiberensis C.H.Wright were separated for the first time using two chromatographic methods for comparison: counter-current chromatography (CCC) coupled with evaporative light scattering detector (ELSD) and preparative reversed phase high-performance liquid chromatography (RP-HPLC) with an ultraviolet detector. Ethyl acetate-n-butanol-methanol-water (4:1:2:4, v/v) was chosen as the two-phase solvent system for CCC, while the acetonitrile-water (25:75 for the first step and15:85 for the second step, v/v) was used as the mobile phase in the preparative RP-HPLC. The following five steroid saponins were purified by theses two chromatographic methods, in one-step operation by CCC and by two-step operation in preparative RP-HPLC: 1) 26-O-β-D- glucopyranosyl-(25R)-furost-5-en-3β, 22ζ, 26-triol-3-O-[β-D-glucopyranosyl-(1→3)-β-D-glucopyranosyl-(1→4)-α-L-rhamnopyranosyl-(1→2)]-β-D-glucopyranoside (compound A), 2) 26-O-β-D-glucopyranosyl-(25R)-furost-5-en-3β, 22ζ, 4) 26-triol-3-O-[β-D-glucopyranosyl-(1→3)-α-L-rhamnopyranosyl-(1→2)]-β-D-glucopyranoside (compound B), 3) 26-O-β-D-glucopyranosyl-(25R)-furost-5-en-3β, 22ζ, 26-triol-3-O-[α-L-rhamnopyranosyl-(1→4)]-β-D-glucopyranoside (compound C), 4) 26-O-β-D-glucopyranosyl-(25R)-furost-5, 20(22)-diene-3β, 26-diol-3-O-{α-L-rhamnopyranosyl-(1→4)-[β-D-glucopyranosyl-(1→3)-β-D-glucopyranosyl-(1→2)]}-β-D-glucopyranoside (compound D) and 5) 26-O-β-D-glucopyranosyl-(25R)-furost-5, 20(22)-diene-3β, 26-diol-3-O-[β-D-glucopyranosyl-(1→4)-α-L-rhamnopyranosy-(1→2)]-β-D-glucopyranoside (compound E). The purities of these five steroid saponins separated by both methods were over 95%, and structural identification of these compounds was performed by ESI-MS, and 13C NMR. Comparison of these two established approaches revealed that CCC required a longer separation time but with less solvent consumption, whereas preparative RP-HPLC gave a shorter separation time but with higher solvent consumption. These results demonstrated that either of these two methods of different separation mechanism is feasible, economical and efficient for rapid preparative isolation and purification of steroid saponins from Dioscorea zingiberensis C.H.Wright. PMID:26726306

  16. Comparative studies on performance of CCC and preparative RP-HPLC in separation and purification of steroid saponins from Dioscorea zingiberensis C.H.Wright.

    PubMed

    Zhang, Xinxin; Liang, Jinru; Zhang, Yongmin; Liu, Jianli; Sun, Wenji; Ito, Yoichiro

    2015-03-01

    Steroid saponins from Dioscorea zingiberensis C.H.Wright were separated for the first time using two chromatographic methods for comparison: counter-current chromatography (CCC) coupled with evaporative light scattering detector (ELSD) and preparative reversed phase high-performance liquid chromatography (RP-HPLC) with an ultraviolet detector. Ethyl acetate-n-butanol-methanol-water (4:1:2:4, v/v) was chosen as the two-phase solvent system for CCC, while the acetonitrile-water (25:75 for the first step and15:85 for the second step, v/v) was used as the mobile phase in the preparative RP-HPLC. The following five steroid saponins were purified by theses two chromatographic methods, in one-step operation by CCC and by two-step operation in preparative RP-HPLC: 1) 26-O-β-D- glucopyranosyl-(25R)-furost-5-en-3β, 22ζ, 26-triol-3-O-[β-D-glucopyranosyl-(1→3)-β-D-glucopyranosyl-(1→4)-α-L-rhamnopyranosyl-(1→2)]-β-D-glucopyranoside ( compound A ), 2) 26-O-β-D-glucopyranosyl-(25R)-furost-5-en-3β, 22ζ, 4) 26-triol-3-O-[β-D-glucopyranosyl-(1→3)-α-L-rhamnopyranosyl-(1→2)]-β-D-glucopyranoside ( compound B ), 3) 26-O-β-D-glucopyranosyl-(25R)-furost-5-en-3β, 22ζ, 26-triol-3-O-[α-L-rhamnopyranosyl-(1→4)]-β-D-glucopyranoside ( compound C ), 4) 26-O-β-D-glucopyranosyl-(25R)-furost-5, 20(22)-diene-3β, 26-diol-3-O-{α-L-rhamnopyranosyl-(1→4)-[β-D-glucopyranosyl-(1→3)-β-D-glucopyranosyl-(1→2)]}-β-D-glucopyranoside ( compound D ) and 5) 26-O-β-D-glucopyranosyl-(25R)-furost-5, 20(22)-diene-3β, 26-diol-3-O-[β-D-glucopyranosyl-(1→4)-α-L-rhamnopyranosy-(1→2)]-β-D-glucopyranoside ( compound E ). The purities of these five steroid saponins separated by both methods were over 95%, and structural identification of these compounds was performed by ESI-MS, and 13 C NMR. Comparison of these two established approaches revealed that CCC required a longer separation time but with less solvent consumption, whereas preparative RP-HPLC gave a shorter separation time but with higher solvent consumption. These results demonstrated that either of these two methods of different separation mechanism is feasible, economical and efficient for rapid preparative isolation and purification of steroid saponins from Dioscorea zingiberensis C.H.Wright.

  17. Development of a perfusion reversed-phase high performance liquid chromatography method for the characterisation of maize products using multivariate analysis.

    PubMed

    Rodriguez-Nogales, J M; Garcia, M C; Marina, M L

    2006-02-03

    A perfusion reversed-phase high performance liquid chromatography (RP-HPLC) method has been designed to allow rapid (3.4 min) separations of maize proteins with high resolution. Several factors, such as extraction conditions, temperature, detection wavelength and type and concentration of ion-pairing agent were optimised. A fine optimisation of the gradient elution was also performed by applying experimental design. Commercial maize products for human consumption (flours, precocked flours, fried snacks and extruded snacks) were characterised for the first time by perfusion RP-HPLC and their chromatographic profiles allowed a differentiation among products relating the different technological process used for their preparation. Furthermore, applying discriminant analysis makes it possible to group the samples according with the technological process suffered by maize products, obtaining a good prediction in 92% of the samples.

  18. Determination of some phenolic compounds in red wine by RP-HPLC: method development and validation.

    PubMed

    Burin, Vívian Maria; Arcari, Stefany Grützmann; Costa, Léa Luzia Freitas; Bordignon-Luiz, Marilde T

    2011-09-01

    A methodology employing reversed-phase high-performance liquid chromatography (RP-HPLC) was developed and validated for simultaneous determination of five phenolic compounds in red wine. The chromatographic separation was carried out in a C(18) column with water acidify with acetic acid (pH 2.6) (solvent A) and 20% solvent A and 80% acetonitrile (solvent B) as the mobile phase. The validation parameters included: selectivity, linearity, range, limits of detection and quantitation, precision and accuracy, using an internal standard. All calibration curves were linear (R(2) > 0.999) within the range, and good precision (RSD < 2.6%) and recovery (80-120%) was obtained for all compounds. This method was applied to quantify phenolics in red wine samples from Santa Catarina State, Brazil, and good separation peaks for phenolic compounds in these wines were observed.

  19. Development and validation of micellar liquid chromatographic methods for the determination of antibiotics in different matrixes.

    PubMed

    Rambla-Alegre, Maria; Esteve-Romero, Josep; Carda-Broch, Samuel

    2011-01-01

    Antibiotics are the most important bioactive and chemotherapeutic compounds to be produced by microbiological synthesis, and they have proved their worth in a variety of fields, such as medicinal chemistry, agriculture, and the food industry. Interest in antibiotics has grown in parallel with an increasingly high degree of productivity in the field of analytical applications. Therefore, it is necessary to develop chromatographic procedures capable of determining various drugs simultaneously in the shortest possible time. Micellar liquid chromatography (MLC) is an RP-HPLC technique that offers advantages over conventional HPLC as far as sample preparation, selectivity, and versatility are concerned. Its main advantage is that samples can be injected directly into the chromatographic system with no previous preparation step. This paper mainly focuses on the results of the authors' own recent research and reports the chromatographic conditions for determination of various antibiotics (penicillins, quinolones, and sulfonamides) in different matrixes (pharmaceuticals, biological fluids, and food). The work of other authors on MLC-based antibiotic determination has been included.

  20. Chromatographic and Spectrophotometric Analysis of Phenolic Compounds from Fruits of Libidibia ferrea Martius

    PubMed Central

    Ferreira, Magda R. A.; Fernandes, Mônica T. M.; da Silva, Wliana A. V.; Bezerra, Isabelle C. F.; de Souza, Tatiane P.; Pimentel, Maria F.; Soares, Luiz A. L.

    2016-01-01

    Background: Libidibia ferrea (Mart. ex Tul.) L.P. Queiroz (Fabaceae) is a tree which is native to Brazil, widely known as “Jucá,” where its herbal derivatives are used in folk medicine with several therapeutic properties. The constituents, which have already been described in the fruit, are mainly hydrolysable tannins (gallic acid [GA] and ellagic acid [EA]). Objective: The aim of this study was to investigate the phenolic variability in the fruit of L. ferrea by ultraviolet/visible (UV/VIS) and chromatographic methods (high-performance liquid chromatography [HPLC]/high-performance thin layer chromatography [HPTLC]). Materials and Methods: Several samples were collected from different regions of Brazil and the qualitative (fingerprints by HPTLC and HPLC) and quantitative analysis (UV/VIS and HPLC) of polyphenols were performed. Results: The HPTLC and HPLC profiles allowed separation and identification of both major analytical markers: EA and GA. The chemical profiles were similar in a number of spots or peaks for the samples, but some differences could be observed in the intensity or area of the analytical markers for HPTLC or HPLC, respectively. Regarding the quantitative analysis, the polyphenolic content by UV/VIS ranged from 13.99 to 37.86 g% expressed as GA or from 10.75 to 29.09 g% expressed as EA. The contents of EA and GA by liquid chromatography-reversed phase (LC-RP) method ranged from 0.57 to 2.68 g% and from 0.54 to 3.23 g%, respectively. Conclusion: The chemical profiles obtained by HPTLC or HPLC, as well as the quantitative analysis by spectrophotometry or LC-RP method, were suitable for discrimination of each herbal sample and can be used as tools for the comparative analysis of the fruits from L. ferrea. SUMMARY The polyphenols of fruits of Libidibia ferrea can be quantified by UV/VIS and HPLCThe HPLC method was able to detect the gallic and ellagic acids in several samples of fruits of Libidibia ferreaThe phenolic profiles of fruits from Libidibia ferrea by HPTLC and HPLC were reproductible. Abbreviations used: HPTLC: high performance thin layer chromatography, HPLC: high performance liquid chromatography, UV-Vis: spectrophotometry PMID:27279721

  1. Offline pentafluorophenyl (PFP)-RP prefractionation as an alternative to high-pH RP for comprehensive LC-MS/MS proteomics and phosphoproteomics.

    PubMed

    Grassetti, Andrew V; Hards, Rufus; Gerber, Scott A

    2017-07-01

    Technological advances in liquid chromatography and tandem mass spectrometry (LC-MS/MS) have enabled comprehensive analyses of proteins and their post-translational modifications from cell culture and tissue samples. However, sample complexity necessitates offline prefractionation via a chromatographic method that is orthogonal to online reversed-phase high-performance liquid chromatography (RP-HPLC). This additional fractionation step improves target identification rates by reducing the complexity of the sample as it is introduced to the instrument. A commonly employed offline prefractionation method is high pH reversed-phase (Hi-pH RP) chromatography. Though highly orthogonal to online RP-HPLC, Hi-pH RP relies on buffers that interfere with electrospray ionization. Thus, samples that are prefractionated using Hi-pH RP are typically desalted prior to LC-MS/MS. In the present work, we evaluate an alternative offline prefractionation method, pentafluorophenyl (PFP)-based reversed-phase chromatography. Importantly, PFP prefractionation results in samples that are dried prior to analysis by LC-MS/MS. This reduction in sample handling relative to Hi-pH RP results in time savings and could facilitate higher target identification rates. Here, we have compared the performances of PFP and Hi-pH RP in offline prefractionation of peptides and phosphopeptides that have been isolated from human cervical carcinoma (HeLa) cells. Given the prevalence of isobaric mass tags for peptide quantification, we evaluated PFP chromatography of peptides labeled with tandem mass tags. Our results suggest that PFP is a viable alternative to Hi-pH RP for both peptide and phosphopeptide offline prefractionation.

  2. C-glucosidic ellagitannins from Lythri herba (European Pharmacopoeia): chromatographic profile and structure determination.

    PubMed

    Piwowarski, Jakub P; Kiss, Anna K

    2013-01-01

    Lythri herba, a pharmacopoeial plant material (European Pharmacopoea), is obtained from flowering parts of purple loosestrife (Lythrum salicaria L.). Although extracts from this plant material have been proven to possess some interesting biological activities and its pharmacopoeial standardisation is based on total tannin content determination, the phytochemical characterisation of this main group of compounds has not yet been fully conducted. To isolate ellagitannins from Lythri herba, determine their structures and develop chromatographic methods for their qualitative analysis. Five C-glucosidic ellagitannins - monomeric- vescalagin and castalagin together with new dimeric structures - salicarinins A-C, composed of vescalagin and stachyurin, vescalagin and casuarinin, castalagin and casuarinin units connected via formation of valoneoyl group, were isolated using column chromatography and preparative HPLC. Structures were determined according to (1) H and (13) C-NMR (one- and two-dimensional), electrospray ionisation-time of flight (ESI-TOF), electrospray ionisation-ion trap (ESI-MS(n) ) and circular dichroism (CD) spectra, together with acidic hydrolysis products analysis. HPTLC on RP-18 modified plates and HPLC-DAD-MS(n) on RP-18 column methods were developed for separation of the five main ellagitannins. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Simultaneous separation and analysis of water- and fat-soluble vitamins on multi-modal reversed-phase weak anion exchange material by HPLC-UV.

    PubMed

    Dabre, Romain; Azad, Nazanin; Schwämmle, Achim; Lämmerhofer, Michael; Lindner, Wolfgang

    2011-04-01

    Several methods for the separation of vitamins on HPLC columns were already validated in the last 20 years. However, most of the techniques focus on separating either fat- or water-soluble vitamins and only few methods are intended to separate lipophilic and hydrophilic vitamins simultaneously. A mixed-mode reversed-phase weak anion exchange (RP-WAX) stationary phase was developed in our laboratory in order to address such mixture of analytes with different chemical characteristics, which are difficult to separate on standard columns. The high versatility in usage of the RP-WAX chromatographic material allowed a baseline separation of ten vitamins within a single run, seven water-soluble and three fat-soluble, using three different chromatographic modes: some positively charged vitamins are eluted in ion exclusion and ion repulsion modes whereas the negatively charged molecules are eluted in the ion exchange mechanism. The non-charged molecules are eluted in a classical reversed-phase mode, regarding their polarities. The method was validated for the vitamin analysis in tablets, evaluating selectivity, robustness, linearity, accuracy, and precision. The validated method was finally employed for the analysis of the vitamin content of some commercially available supplement tablets. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Gradient HPLC of antibiotics in urine, ground water, chicken muscle, hospital wastewater, and pharmaceutical samples using C-18 and RP-amide columns.

    PubMed

    Kumar, Ashwini; Kumar Malik, Ashok; Kumar Tewary, Dhananjay; Singh, Baldev

    2008-02-01

    A simple and highly sensitive high pressure liquid chromatographic (HPLC-UV) method has been developed for the determination of ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid, in mobile phase citrate buffer (0.001 M) of pH 4.5 prepared in water (X), methanol (Y), and ACN (Z) using gradient at a flow rate of 1.0 mL/min by direct UV absorbance detection at lambda = 280 nm. Separation of analytes was studied on the C-18 and RP-amide columns and best results were observed on the RP-amide column with LODs (3.3 x S/m) 0.89, 0.55, 0.67, and 1.41 ng/mL for ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid, respectively, and better RSD than the C-18 column. The recovery of Fluoroquinolones (FQs) in urine, ground water, hospital wastewater, and chicken muscle using this method is more than 90%. The method was successfully applied to the analysis of ofloxacin, lomefloxacin, cinoxacin, and nalidixic acid in urine, ground water, pharmaceutical dosage forms, hospital wastewater, and chicken muscle.

  5. Validated RP-HPLC/DAD Method for the Quantification of Insect Repellent Ethyl 2-Aminobenzoate in Membrane-Moderated Matrix Type Monolithic Polymeric Device.

    PubMed

    Islam, Johirul; Zaman, Kamaruz; Chakrabarti, Srijita; Sharma Bora, Nilutpal; Mandal, Santa; Pratim Pathak, Manash; Srinivas Raju, Pakalapati; Chattopadhyay, Pronobesh

    2017-07-01

    A simple, accurate and sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the estimation of ethyl 2-aminobenzoate (EAB) in a matrix type monolithic polymeric device and validated as per the International Conference on Harmonization guidelines. The analysis was performed isocratically on a ZORBAX Eclipse plus C18 analytical column (250 × 4.4 mm, 5 μm) and a diode array detector (DAD) using acetonitrile and water (75:25 v/v) as the mobile phase by keeping the flow-rate constant at 1.0 mL/min. Determination of EAB was not interfered in the presence of excipients. Inter- and intra-day relative standard deviations were not higher than 2%. Mean recovery was between 98.7 and 101.3%. Calibration curve was linear in the concentration range of 0.5-10 µg/mL. Limits of detection and quantification were 0.19 and 0.60 µg/mL, respectively. Thus, the present report put forward a novel method for the estimation of EAB, an emerging insect repellent, by using RP-HPLC technique. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Microwave-assisted extraction with water for fast extraction and simultaneous RP-HPLC determination of phenolic acids in radix Salviae Miltiorrhizae.

    PubMed

    Fang, Xinsheng; Wang, Jianhua; Zhou, Hongying; Jiang, Xingkai; Zhu, Lixiang; Gao, Xin

    2009-07-01

    An optimized microwave-assisted extraction method using water (MAE-W) as the extractant and an efficient HPLC analysis method were first developed for the fast extraction and simultaneous determination of D(+)-(3,4-dihydroxyphenyl) lactic acid (Dla), salvianolic acid B (SaB), and lithospermic acid (La) in radix Salviae Miltiorrhizae. The key parameters of MAE-W were optimized. It was found that the degradation of SaB was inhibited when using the optimized MAE-W and the stable content of Dla, La, and SaB in danshen was obtained. Furthermore, compared to the conventional extraction methods, the proposed MAE-W is a more rapid method with higher yield and lower solvent consumption with a reproducibility (RSD <6%). In addition, using water as extractant is safe and helpful for environment protection, which could be referred to as green extraction. The separation and quantitative determination of the three compounds was carried out by a developed reverse-phase high-performance liquid chromatographic (RP-HPLC) method with UV detection. Highly efficient separation was obtained using gradient solvent system. The optimized HPLC analysis method was validated to have specificity, linearity, precision, and accuracy. The results indicated that MAE-W followed by HPLC-UV determination is an appropriate alternative to previously proposed method for quality control of radix Salviae Miltiorrhizae.

  7. Determination of ambroxol hydrochloride, guaifenesin, and theophylline in ternary mixtures and in the presence of excipients in different pharmaceutical dosage forms.

    PubMed

    Abdelwahab, Nada S

    2012-01-01

    Determination of ternary mixtures of ambroxol hydrochloride, guaifenesin, and theophylline with minimum sample pretreatment and without analyte separation has been successfully achieved by using chemometric and RP-HPLC methods. The developed chemometric models are partial least squares (PLS) and genetic algorithm coupled with PLS. Data of the analyses were obtained from UV-Vis spectra of the studied drugs in different concentration ranges. These models have been successfully updated to be applied for determination of the proposed drugs in Farcosolvin syrup and in the presence of a syrup excipient (methyl paraben). In the developed RP-HPLC method, chromatographic runs were performed on an RP-C18 analytical column with the isocratic mobile phase 0.05 M phosphate buffer-methanol-acetonitrile-triethylamine (63.5 + 27.5 + 9 + 0.25, v/v/v/v, pH 5.5 adjusted with orthophosphoric acid) at a flow rate of 1.2 mL/min. The analytes were detected and quantified at 220 nm. The method was optimized in order to obtain good resolution between the studied components and to prevent interference from methyl paraben. Method validation was performed with respect to International Conference on Harmonization guidelines and the validation acceptance criteria were met in all cases. The proposed methods can be considered acceptable for QC of the studied drugs in pharmaceutical capsules and syrup. The results obtained by the suggested chemometric methods for determination of the studied mixture in different pharmaceutical preparations were statistically compared to those obtained by applying the developed RP-HPLC method, and no significant difference was found.

  8. Linear modeling of the soil-water partition coefficient normalized to organic carbon content by reversed-phase thin-layer chromatography.

    PubMed

    Andrić, Filip; Šegan, Sandra; Dramićanin, Aleksandra; Majstorović, Helena; Milojković-Opsenica, Dušanka

    2016-08-05

    Soil-water partition coefficient normalized to the organic carbon content (KOC) is one of the crucial properties influencing the fate of organic compounds in the environment. Chromatographic methods are well established alternative for direct sorption techniques used for KOC determination. The present work proposes reversed-phase thin-layer chromatography (RP-TLC) as a simpler, yet equally accurate method as officially recommended HPLC technique. Several TLC systems were studied including octadecyl-(RP18) and cyano-(CN) modified silica layers in combination with methanol-water and acetonitrile-water mixtures as mobile phases. In total 50 compounds of different molecular shape, size, and various ability to establish specific interactions were selected (phenols, beznodiazepines, triazine herbicides, and polyaromatic hydrocarbons). Calibration set of 29 compounds with known logKOC values determined by sorption experiments was used to build simple univariate calibrations, Principal Component Regression (PCR) and Partial Least Squares (PLS) models between logKOC and TLC retention parameters. Models exhibit good statistical performance, indicating that CN-layers contribute better to logKOC modeling than RP18-silica. The most promising TLC methods, officially recommended HPLC method, and four in silico estimation approaches have been compared by non-parametric Sum of Ranking Differences approach (SRD). The best estimations of logKOC values were achieved by simple univariate calibration of TLC retention data involving CN-silica layers and moderate content of methanol (40-50%v/v). They were ranked far well compared to the officially recommended HPLC method which was ranked in the middle. The worst estimates have been obtained from in silico computations based on octanol-water partition coefficient. Linear Solvation Energy Relationship study revealed that increased polarity of CN-layers over RP18 in combination with methanol-water mixtures is the key to better modeling of logKOC through significant diminishing of dipolar and proton accepting influence of the mobile phase as well as enhancing molar refractivity in excess of the chromatographic systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.

    PubMed

    Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El

    2017-06-27

    HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  10. A novel, simple and inexpensive procedure for the simultaneous determination of iopamidol and p-aminohippuric acid for renal function assessment from plasma samples in awake rats.

    PubMed

    Rodríguez-Romero, Violeta; González-Villalva, Karla I; Reyes, José L; Franco-Bourland, Rebecca E; Guízar-Sahagún, Gabriel; Castañeda-Hernández, Gilberto; Cruz-Antonio, Leticia

    2015-03-25

    The purpose of the current study was to design, validate and implement a novel analytical method for the simultaneous plasma measurement of iopamidol and p-aminohippuric acid (PAH) to estimate renal function in awake rats. A reverse-phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous measurement of iopamidol (for glomerular filtration rate estimation, GFR) and PAH (for tubular secretion determination, TS) was designed and validated using a C-18 column, 0.1M acetic acid-10% acetonitrile (90:10, v/v) as mobile phase, at a flow rate of 0.3 ml/min, and UV detection at 270 nm. Iopamidol (244.8 mg/kg) was administered intravenously followed immediately by sodium PAH (100 mg/kg) to healthy female Sprague-Dawley rats. Plasma samples obtained at 2.5, 5, 10, 15, 20, 30, 45, 60, 90, and 120 min after drug administration were deproteinized with 2.5% trichloroacetic acid containing p-aminobenzoic acid as internal standard, and separated by the validated RP-HPLC method described above. The iopamidol and PAH chromatographic data were analyzed using a non-compartmental model. The results demonstrated that the RP-HPLC method was linear in ranges between 15-120 μg/ml and 2.5-120 μg/ml for iopamidol and PAH, respectively. Precision and accuracy were within 15% for both drugs. Recovery of iopamidol and PAH was 92% and 100%, respectively. Plasma iopamidol and PAH clearances in awake rats, estimates for GFR and TS, respectively, were 1.49±0.20 ml/min and 3.73±0.38 ml/min. In conclusion, the method here described is a simple and reliable procedure, for the simultaneous and time-saving determination of GFR and TS from plasma samples in the conscious rat. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. RP-HPLC ANALYSIS OF ACIDIC AND BASIC DRUGS IN SYSTEMS WITH DIETHYLAMINE AS ELUENTS ADDITIVE.

    PubMed

    Petruczynik, Anna; Wroblewski, Karol; Strozek, Szymon; Waksmundzka-Hajnos, Monika

    2016-11-01

    The chromatographic behavior of some basic and acidic drugs was studied on Cl 8, Phenyl-Hexyl and Polar RP columns with methanol or acetonitrile as organic modifiers of aqueous mobile phases containing addition of diethylamine. Diethylamine plays a double function of silanol blocker reagent in analysis of basic drugs and ion-pair reagent in analysis of acidic drugs. Most symmetrical peaks and highest system efficiency were obtained on Phenyl-Hexyl and Polar RP columns in tested mobile phase systems compared to results obtained on C18 column. A new rapid, simple, specific and accurate reverse phase liquid chromatographic method was developed for the simultaneous determination of atorvastatin - antihyperlipidemic drug and amlodipine - calcium channel blocker in one pharmaceutical formulation. Atorvastatin is an acidic compounds while amlodipine is a basic substance. The chromatographic separation was carried out on Phenyl-Hexyl column by gradient elution mode with acetonitrile as organic modifier, acetate buffer at pH 3.5 and Q.025 M/L diethylamine. The proposed method was validated for specificity, precision, accuracy, linearity, and robustness. The linearity range of atorvastatin and amlodipine for 5 - 100 μg/mL was obtained with limits of-detection (LOD) 3.2750 gg/mL and 3.2102 μg/mL, respectively. The proposed method made use of DAD as a tool for peak identity and purity confirmation.

  12. [Influences of ion-suppressors on retention behaviors of nine food additives in reversed-phase high performance liquid chromatographic separation].

    PubMed

    Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong

    2011-10-01

    The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods.

  13. [Study on HPLC fingerprint of 11 Taraxacum species in northeast of China].

    PubMed

    Zhu, Dan; Zhao, Xin; Xu, Qiao; Ning, Wei

    2011-04-01

    To study the RP-HPLC fingerprints of 11 plants in the genus Taraxacum for their quality control. The fingerprints were determined using an Agilent 1100 series instrument system. Chromatographic analyses were performed on a Kromasil 100-5 C18 (4.6 mm x 250 mm, 5 microm) analytical column,eluted with methanol and water containing 0.5% acetic acid as the mobile phases in gradient elution at the flow rate of 1.0 mL x min(-1). The detection wavelength was 323 nm. The temperature of column was 35 degrees C. Eleven species of Taraxacum in northeast of China were detected respectively. Twenty-five common peaks existed in 11 RP-HPLC fingerprints. By comparing the retention time and the on-line UV spectra, peaks No. 10, No. 12, No. 16 and No. 25 were identified as chlorogenic acid, caffeic acid, p-coumaroy acid and luteolin respectively. The analytical method with good precision and reproducibility can be useful in the quality control of Taraxacum plants.

  14. Intracellular nucleotide and nucleotide sugar contents of cultured CHO cells determined by a fast, sensitive, and high-resolution ion-pair RP-HPLC.

    PubMed

    Kochanowski, N; Blanchard, F; Cacan, R; Chirat, F; Guedon, E; Marc, A; Goergen, J-L

    2006-01-15

    Analysis of intracellular nucleotide and nucleotide sugar contents is essential in studying protein glycosylation of mammalian cells. Nucleotides and nucleotide sugars are the donor substrates of glycosyltransferases, and nucleotides are involved in cellular energy metabolism and its regulation. A sensitive and reproducible ion-pair reverse-phase high-performance liquid chromatography (RP-HPLC) method has been developed, allowing the direct and simultaneous detection and quantification of some essential nucleotides and nucleotide sugars. After a perchloric acid extraction, 13 molecules (8 nucleotides and 5 nucleotide sugars) were separated, including activated sugars such as UDP-glucose, UDP-galactose, GDP-mannose, UDP-N-acetylglucosamine, and UDP-N-acetylgalactosamine. To validate the analytical parameters, the reproducibility, linearity of calibration curves, detection limits, and recovery were evaluated for standard mixtures and cell extracts. The developed method is capable of resolving picomolar quantities of nucleotides and nucleotide sugars in a single chromatographic run. The HPLC method was then applied to quantify intracellular levels of nucleotides and nucleotide sugars of Chinese hamster ovary (CHO) cells cultivated in a bioreactor batch process. Evolutions of the titers of nucleotides and nucleotide sugars during the batch process are discussed.

  15. Simultaneous Estimation of Withaferin A and Z-Guggulsterone in Marketed Formulation by RP-HPLC.

    PubMed

    Agrawal, Poonam; Vegda, Rashmi; Laddha, Kirti

    2015-07-01

    A simple, rapid, precise and accurate high-performance liquid chromatography (HPLC) method was developed for simultaneous estimation of withaferin A and Z-guggulsterone in a polyherbal formulation containing Withania somnifera and Commiphora wightii. The chromatographic separation was achieved on a Purosphere RP-18 column (particle size 5 µm) with a mobile phase consisting of Solvent A (acetonitrile) and Solvent B (water) with the following gradients: 0-7 min, 50% A in B; 7-9 min, 50-80% A in B; 9-20 min, 80% A in B at a flow rate of 1 mL/min and detection at 235 nm. The marker compounds were well separated on the chromatogram within 20 min. The results obtained indicate accuracy and reliability of the developed simultaneous HPLC method for the quantification of withaferin A and Z-guggulsterone. The proposed method was found to be reproducible, specific, precise and accurate for simultaneous estimation of these marker compounds in a combined dosage form. The HPLC method was appropriate and the two markers are well resolved, enabling efficient quantitative analysis of withaferin A and Z-guggulsterone. The method can be successively used for quantitative analysis of these two marker constituents in combination of marketed polyherbal formulation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. RP-HPLC Method Development and Validation for Determination of Eptifibatide Acetate in Bulk Drug Substance and Pharmaceutical Dosage Forms.

    PubMed

    Bavand Savadkouhi, Maryam; Vahidi, Hossein; Ayatollahi, Abdul Majid; Hooshfar, Shirin; Kobarfard, Farzad

    2017-01-01

    A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 column (150 x 4.60 mm i.d., 5 µM particle size) at ambient temperature using acetonitrile (ACN), water and trifluoroacetic acid (TFA) as mobile phase at flow rate of 1 mL/min and UV detection at 275 nm. Eptifibatide acetate exhibited linearity over the concentration range of 0.15-2 mg/mL (r 2 =0.997) with limit of detection of 0.15 mg/mL The accuracy of the method was 96.4-103.8%. The intra-day and inter-day precision were between 0.052% and 0.598%, respectively. The present successfully validated method with excellent selectivity, linearity, sensitivity, precision and accuracy was applicable for the assay of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms.

  17. Identification and Characterization of Asulam Impurities in Self Made Bulk Batch Synthesis and Quantification by RP-HPLC Method.

    PubMed

    Mahaboob Basha, D; Venkata Reddy, G; Gopi Krishna, Y; Kumara Swamy, B E; Vijay, Rajani

    2018-04-19

    The first approach of this research paper explores the simultaneous characterization and determination of theAsulam active ingredient and its associated nine impurities in bulk batch production by the gradient reverse-phase high-performance liquid chromatographic (RP-HPLC) method. The best separation from its potential impurities and reproducible method was achieved by selecting the Cosmosil C-18 (250 × 4.6 mm, 5 μm particle size) analytical column with a run time of 40 min. The pumping chromatographic mobile phase was composed of 0.1% formic acid in milli-Q water (pH ~2.72) and methanol (80 + 20, v/v). An ambient column-oven temperature and UV detection at 260 nm were used. For this broad resolution, a gradient program was employed at a flow rate of 1.20 mL/min. All potential related substances in Asulam bulk manufacturing were ascertained by mass, proton nuclear magnetic resonance, and infrared spectroscopy. The developed HPLC method was validated with respect to linearity (25.64-151.83 mg/L for Asulam and 0.71-16.29, 1.02-12.26, 1.01-20.29, 0.60-10.01, 1.04-16.65, 0.94-22.47, 0.93-16.60, 1.00-12.45, 1.00-12.45, and 0.71-12.17 mg/L for Impurities A to I with a correlation coefficient 0.999 for Asulam and all the impurities), precision (RSD, % for active analyte Asulam and impurities were ˂2%), accuracy (percent recovery for Asulam at two levels ranged from 99.28 to 99.35%, and for Impurities A to I, it was 93.44 to 101.41%), and specificity. Hence, this simple and reliable HPLC method was able to determine the purity of Asulam active analyte and the level of impurities in bulk batch synthesis. By using this quantified procedure, five self-made production batches were analyzed simultaneously.

  18. Development and validation of an RP-HPLC method for the quantitation of odanacatib in rat and human plasma and its application to a pharmacokinetic study.

    PubMed

    Police, Anitha; Gurav, Sandip; Dhiman, Vinay; Zainuddin, Mohd; Bhamidipati, Ravi Kanth; Rajagopal, Sriram; Mullangi, Ramesh

    2015-11-01

    A simple, specific, sensitive and reproducible high-performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of odanacatib in rat and human plasma. The bioanalytical procedure involves extraction of odanacatib and itraconazole (internal standard, IS) from a 200 μL plasma aliquot with simple liquid-liquid extraction process. Chromatographic separation was achieved on a Symmetry Shield RP18 using an isocratic mobile phase at a flow rate of 0.7 mL/min. The UV detection wave length was 268 nm. Odanacatib and IS eluted at 5.5 and 8.6 min, respectively with a total run time of 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 50.9-2037 ng/mL (r(2) = 0.994). The intra- and inter-day precisions were in the range of 2.06-5.11 and 5.84-13.1%, respectively, in rat plasma and 2.38-7.90 and 6.39-10.2%, respectively, in human plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Validated chromatographic and spectrophotometric methods for analysis of some amoebicide drugs in their combined pharmaceutical preparation.

    PubMed

    Abdelaleem, Eglal Adelhamid; Abdelwahab, Nada Sayed

    2013-01-01

    This work is concerned with development and validation of chromatographic and spectrophotometric methods for analysis of mebeverine HCl (MEH), diloxanide furoate (DF) and metronidazole (MET) in Dimetrol® tablets - spectrophotometric and RP-HPLC methods using UV detection. The developed spectrophotometric methods depend on determination of MEH and DF in the combined dosage form using the successive derivative ratio spectra method which depends on derivatization of the obtained ratio spectra in two steps using methanol as a solvent and measuring MEH at 226.4-232.2 nm (peak to peak) and DF at 260.6-264.8 nm (peak to peak). While MET concentrations were determined using first derivative (1D) at λ = 327 nm using the same solvent. The chromatographic method depends on HPLC separation on ODS column and elution with a mobile phase consisting water: methanol: triethylamine (25: 75: 0.5, by volume, orthophosphoric acid to pH =4). Pumping the mobile phase at 0.7 ml min-1 with UV at 230 nm. Factors affecting the developed methods were studied and optimized, moreover, they have been validated as per ICH guideline and the results demonstrated that the suggested methods are reproducible, reliable and can be applied for routine use with short time of analysis. Statistical analysis of the two developed methods with each other using F and student's-t tests showed no significant difference.

  20. [A new HPLC procedure for cyclamate in food with pre-chromatographic derivatization].

    PubMed

    Schwedt, G; Hauck, M

    1988-08-01

    A high-pressure liquid chromatography (HPLC) procedure for the detection of cyclamate in liquid and solid samples is presented, which depends on oxidation and the reaction of cyclohexylamine with o-phthaldialdehyde to form a condensation product. The results of the HPLC analysis, using an RP-C 18 separation system with UV detection at 242 nm are reported. Contents, from 2 to 400 mg/l, can be detected in less than 2 h (HPLC analysis within 20 min) with relative standard deviations of 4%. Only for cucumber infusions were incomplete recoveries of 68% obtained.

  1. Rapid high performance liquid chromatography method development with high prediction accuracy, using 5cm long narrow bore columns packed with sub-2microm particles and Design Space computer modeling.

    PubMed

    Fekete, Szabolcs; Fekete, Jeno; Molnár, Imre; Ganzler, Katalin

    2009-11-06

    Many different strategies of reversed phase high performance liquid chromatographic (RP-HPLC) method development are used today. This paper describes a strategy for the systematic development of ultrahigh-pressure liquid chromatographic (UHPLC or UPLC) methods using 5cmx2.1mm columns packed with sub-2microm particles and computer simulation (DryLab((R)) package). Data for the accuracy of computer modeling in the Design Space under ultrahigh-pressure conditions are reported. An acceptable accuracy for these predictions of the computer models is presented. This work illustrates a method development strategy, focusing on time reduction up to a factor 3-5, compared to the conventional HPLC method development and exhibits parts of the Design Space elaboration as requested by the FDA and ICH Q8R1. Furthermore this paper demonstrates the accuracy of retention time prediction at elevated pressure (enhanced flow-rate) and shows that the computer-assisted simulation can be applied with sufficient precision for UHPLC applications (p>400bar). Examples of fast and effective method development in pharmaceutical analysis, both for gradient and isocratic separations are presented.

  2. RP-HPLC Method Development and Validation for Determination of Eptifibatide Acetate in Bulk Drug Substance and Pharmaceutical Dosage Forms

    PubMed Central

    Bavand Savadkouhi, Maryam; Vahidi, Hossein; Ayatollahi, Abdul Majid; Hooshfar, Shirin; Kobarfard, Farzad

    2017-01-01

    A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 column (150 x 4.60 mm i.d., 5 µM particle size) at ambient temperature using acetonitrile (ACN), water and trifluoroacetic acid (TFA) as mobile phase at flow rate of 1 mL/min and UV detection at 275 nm. Eptifibatide acetate exhibited linearity over the concentration range of 0.15-2 mg/mL (r2=0.997) with limit of detection of 0.15 mg/mL The accuracy of the method was 96.4-103.8%. The intra-day and inter-day precision were between 0.052% and 0.598%, respectively. The present successfully validated method with excellent selectivity, linearity, sensitivity, precision and accuracy was applicable for the assay of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms. PMID:28979304

  3. RP-HPLC method for simultaneous estimation of vigabatrin, gamma-aminobutyric acid and taurine in biological samples.

    PubMed

    Police, Anitha; Shankar, Vijay Kumar; Narasimha Murthy, S

    2018-02-15

    Vigabatrin is used as first line drug in treatment of infantile spasms for its potential benefit overweighing risk of causing permanent peripheral visual field defects and retinal damage. Chronic administration of vigabatrin in rats has demonstrated these ocular events are result of GABA accumulation and depletion of taurine levels in retinal tissues. In vigabatrin clinical studies taurine plasma level is considered as biomarker for studying structure and function of retina. The analytical method is essential to monitor taurine levels along with vigabatrin and GABA. A RP-HPLC method has been developed and validated for simultaneous estimation of vigabatrin, GABA and taurine using surrogate matrix. Analytes were extracted from human plasma, rat plasma, retina and brain by simple protein precipitation method and derivatized by naphthalene 2, 3‑dicarboxaldehyde to produce stable fluorescent active isoindole derivatives. The chromatographic analysis was performed on Zorbax Eclipse AAA column using gradient elution profile and eluent was monitored using fluorescence detector. A linear plot of calibration curve was observed in concentration range of 64.6 to 6458, 51.5 to 5150 and 62.5 to 6258 ng/mL for vigabatrin, GABA and taurine, respectively with r 2  ≥ 0.997 for all analytes. The method was successfully applied for estimating levels of vigabatrin and its modulator effect on GABA and taurine levels in rat plasma, brain and retinal tissue. This RP-HPLC method can be applied in clinical and preclinical studies to explore the effect of taurine deficiency and to investigate novel approaches for alleviating vigabatrin induced ocular toxicity. Copyright © 2018. Published by Elsevier B.V.

  4. Correlation of sensory bitterness in dairy protein hydrolysates: Comparison of prediction models built using sensory, chromatographic and electronic tongue data.

    PubMed

    Newman, J; Egan, T; Harbourne, N; O'Riordan, D; Jacquier, J C; O'Sullivan, M

    2014-08-01

    Sensory evaluation can be problematic for ingredients with a bitter taste during research and development phase of new food products. In this study, 19 dairy protein hydrolysates (DPH) were analysed by an electronic tongue and their physicochemical characteristics, the data obtained from these methods were correlated with their bitterness intensity as scored by a trained sensory panel and each model was also assessed by its predictive capabilities. The physiochemical characteristics of the DPHs investigated were degree of hydrolysis (DH%), and data relating to peptide size and relative hydrophobicity from size exclusion chromatography (SEC) and reverse phase (RP) HPLC. Partial least square regression (PLS) was used to construct the prediction models. All PLS regressions had good correlations (0.78 to 0.93) with the strongest being the combination of data obtained from SEC and RP HPLC. However, the PLS with the strongest predictive power was based on the e-tongue which had the PLS regression with the lowest root mean predicted residual error sum of squares (PRESS) in the study. The results show that the PLS models constructed with the e-tongue and the combination of SEC and RP-HPLC has potential to be used for prediction of bitterness and thus reducing the reliance on sensory analysis in DPHs for future food research. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Gradient RP-HPLC method for the determination of potential impurities in atazanavir sulfate.

    PubMed

    Chitturi, Sreenivasa Rao; Somannavar, Yallappa Somappa; Peruri, Badarinadh Gupta; Nallapati, Sreenivas; Sharma, Hemant Kumar; Budidet, Shankar Reddy; Handa, Vijay Kumar; Vurimindi, Hima Bindu

    2011-04-28

    This paper proposes a simple and selective RP-HPLC method for the determination of process impurities and degradation products (degradants) of atazanavir sulfate (ATV) drug substance. Chromatographic separation was achieved on Ascentis(®) Express C8, (150mm×4.6mm, 2.7μm) column thermostated at 30°C under gradient elution by a binary mixture of potassium dihydrogen phosphate (pH 3.5, 0.02M) and ACN at a flow rate of 1.0ml/min. A photodiode array (PDA) detector set at 250nm was used for detection. Stress testing (forced degradation) of ATV was carried out under acidic, alkaline, oxidative, photolytic, thermal and humidity conditions. In presence of alkali, ATV transformed into cyclized products and the order of degradation reaction is determined by the method of initial rates. The unknown process impurities and alkaline degradants are isolated by preparative LC and characterized by ESI-MS/MS, (1)H NMR, and FT-IR spectral data. The developed method is validated with respect to sensitivity (lod and loq), linearity, precision, accuracy and robustness and can be implemented for routine quality control analysis and stability testing of ATV. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Development and validation of a rapid reversed-phase HPLC method for the determination of the non-nucleoside reverse transcriptase inhibitor dapivirine from polymeric nanoparticles.

    PubMed

    das Neves, José; Sarmento, Bruno; Amiji, Mansoor M; Bahia, Maria Fernanda

    2010-06-05

    The objective of this work was to develop and validate a rapid reversed-phase (RP) high-performance liquid chromatography (HPLC) method for the in vitro pharmaceutical characterization of dapivirine-loaded polymeric nanoparticles. Chromatographic runs were performed on a RP C18 column with a mobile phase comprising acetonitrile-0.5% (w/v) triethanolamine solution in isocratic mode (80:20, v/v) at a flow rate of 1 ml/min. Dapivirine was detected at a wavelength of 290 nm. The method was shown to be specific, linear in the range of 1-50 microg/ml (R(2)=0.9998), precise at the intra-day and inter-day levels as reflected by the relative standard deviation values (less than 0.85%), accurate (recovery rate of 100.17+/-0.35%), and robust to changes in the mobile phase and column brand. The detection and quantitation limits were 0.08 and 0.24 microg/ml, respectively. The method was successfully used to determine the loading capacity and association efficiency of dapivirine in poly(lactic-co-glycolic acid)-based nanoparticles and its in vitro release. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  7. Establishment and reliability evaluation of the design space for HPLC analysis of six alkaloids in Coptis chinensis (Huanglian) using Bayesian approach.

    PubMed

    Dai, Sheng-Yun; Xu, Bing; Zhang, Yi; Li, Jian-Yu; Sun, Fei; Shi, Xin-Yuan; Qiao, Yan-Jiang

    2016-09-01

    Coptis chinensis (Huanglian) is a commonly used traditional Chinese medicine (TCM) herb and alkaloids are the most important chemical constituents in it. In the present study, an isocratic reverse phase high performance liquid chromatography (RP-HPLC) method allowing the separation of six alkaloids in Huanglian was for the first time developed under the quality by design (QbD) principles. First, five chromatographic parameters were identified to construct a Plackett-Burman experimental design. The critical resolution, analysis time, and peak width were responses modeled by multivariate linear regression. The results showed that the percentage of acetonitrile, concentration of sodium dodecyl sulfate, and concentration of potassium phosphate monobasic were statistically significant parameters (P < 0.05). Then, the Box-Behnken experimental design was applied to further evaluate the interactions between the three parameters on selected responses. Full quadratic models were built and used to establish the analytical design space. Moreover, the reliability of design space was estimated by the Bayesian posterior predictive distribution. The optimal separation was predicted at 40% acetonitrile, 1.7 g·mL(-1) of sodium dodecyl sulfate and 0.03 mol·mL(-1) of potassium phosphate monobasic. Finally, the accuracy profile methodology was used to validate the established HPLC method. The results demonstrated that the QbD concept could be efficiently used to develop a robust RP-HPLC analytical method for Huanglian. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  8. Determination of thiopurine S-methyltransferase activity by hydrophilic interaction liquid chromatography hyphenated with mass spectrometry.

    PubMed

    Pecher, Daniel; Dokupilová, Svetlana; Zelinková, Zuzana; Peppelenbosch, Maikel; Mikušová, Veronika; Mikuš, Peter

    2017-08-05

    Thiopurine S-methyltransferase (TPMT) plays an important role in the metabolism of thiopurines used in the therapy of inflammatory bowel diseases (IBD). In this work a new progressive method for the determination of TPMT activity in red blood cells lysates was developed. Analysis was carried out by means of hydrophilic interaction liquid chromatography (HILIC) hyphenated with mass spectrometry (MS). In comparison with reversed-phase high-performance liquid chromatography (RP-HPLC), that has been typically applied in determination of TPMT activity, the HILIC significantly improved the analytical signal provided by MS, shortened analysis time, and improved chromatographic resolution. The HILIC-HPLC-MS method was optimized and validated, providing favorable parameters of detection and quantitation limits (5.5 and 16.5pmol/mL, respectively), linearity (coefficient of determination 0.9999 in the range of 0.01-1.0nmol/mL), recovery and precision (93.25-100.37% with RSD 1.06-1.32% in the whole concentration range of QC samples). Moreover, in contrast to the conventional RP-HPLC-UV approach, the complex phenotype TPMT profiles can be reliably and without interferences monitored using the HILIC-HPLC-MS method. Such advanced monitoring can provide valuable detail information on the thiopurines (e.g. evaluating ratio of methylated and non-methylated 6-mercaptopurine) and, by that, TPMT action in biological systems before and during the therapy of IBD. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Analysis of anti-neoplastic drug in bacterial ghost matrix, w/o/w double nanoemulsion and w/o nanoemulsion by a validated 'green' liquid chromatographic method.

    PubMed

    Youssof, Abdullah M E; Salem-Bekhit, Mounir M; Shakeel, Faiyaz; Alanazi, Fars K; Haq, Nazrul

    2016-07-01

    The objective of the present investigation was to develop and validate a 'green' reversed phase high-performance liquid chromatography (RP-HPLC) method for rapid analysis of a cytotoxic drug 5-fluorouracil (5-FU) in bulk drug, marketed injection, water-in-oil (w/o) nanoemulsion, double water-in-oil-in-water (w/o/w) nanoemulsion and bacterial ghost (BG) matrix. The chromatography study was carried out at room temperature (25±1°C) using an HPLC system with the help of ultraviolet (UV)-visible detector. The chromatographic performance was achieved with a Nucleodur 150mm×4.6mm RP C8 column filled with 5µm filler as a static phase. The mobile phase consisted of ethyl acetate: methanol (7:3% v/v) which was delivered at a flow rate of 1.0mLmin(-1) and the drug was detected in UV mode at 254nm. The developed method was validated in terms of linearity (r(2)=0.998), accuracy (98.19-102.09%), precision (% RSD=0.58-1.17), robustness (% RSD=0.12-0.53) and sensitivity with satisfactory results. The efficiency of the method was demonstrated by the assay of the drug in marketed injection, w/o nanoemulsion, w/o/w nanoemulsion and BG with satisfactory results. The successful resolution of the drug along with its degradation products clearly established the stability-indicating nature of the proposed method. Overall, these results suggested that the proposed analytical method could be effectively applied to the routine analysis of 5-FU in bulk drug, various pharmaceutical dosage forms and BG. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Determination of n-octanol/water partition coefficient for DDT-related compounds by RP-HPLC with a novel dual-point retention time correction.

    PubMed

    Han, Shu-ying; Qiao, Jun-qin; Zhang, Yun-yang; Yang, Li-li; Lian, Hong-zhen; Ge, Xin; Chen, Hong-yuan

    2011-03-01

    n-Octanol/water partition coefficients (P) for DDTs and dicofol were determined by reversed-phase high performance liquid chromatography (RP-HPLC) on a C(18) column using methanol-water mixture as mobile phase. A dual-point retention time correction (DP-RTC) was proposed to rectify chromatographic retention time (t(R)) shift resulted from stationary phase aging. Based on this correction, the relationship between logP and logk(w), the logarithm of the retention factor extrapolated to pure water, was investigated for a set of 12 benzene homologues and DDT-related compounds with reliable experimental P as model compounds. A linear regression logP=(1.10±0.04) logk(w) - (0.60±0.17) was established with correlation coefficient R(2) of 0.988, cross-validated correlation coefficient R(cv)(2) of 0.983 and standard deviation (SD) of 0.156. This model was further validated using four verification compounds, naphthalene, biphenyl, 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (p,p'-DDD) and 2,2-bis(4-chlorophenyl)-1,1-dichloroethene (p,p'-DDE) with similar structure to DDT. The RP-HPLC-determined P values showed good consistency with shake-flask (SFM) or slow-stirring (SSM) results, especially for highly hydrophobic compounds with logP in the range of 4-7. Then, the P values for five DDT-related compounds, 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1,1-trichloroethane (o,p'-DDT), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethane (o,p'-DDD), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene (o,p'-DDE), and 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its main degradation product 4,4'-dichlorobenzophenone (p,p'-DBP) were evaluated by the improved RP-HPLC method for the first time. The excellent precision with SD less than 0.03 proved that the novel DP-RTC protocol can significantly increases the determination accuracy and reliability of P by RP-HPLC. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor with HPLC and electrochemical detection.

    PubMed

    Kuhlmann, O; Stoldt, G; Struck, H G; Krauss, G J

    1998-09-01

    A sensitive and selective bioanalytical method for simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor using reversed-phase HPLC and electrochemical detection is described. Chromatographic separation was achieved by using a Regis SPS 100 RP-8 column (5 microns; 150 x 4.6 mm I.D.). This support is coated with a hydrophilic polyoxyethylenepolymer. It allows protein-containing samples to be injected directly onto the column. The electrochemical detector permit a detection limit of 500 pg diclofenac per ml (daily relative standard deviation 6.3%) and 50 ng oxybuprocaine per ml (daily R.S.D. 2.6%), respectively. Results of administered and measured drug-concentrations in time dependent decrease are presented.

  12. Analytical Eco-Scale for Assessing the Greenness of a Developed RP-HPLC Method Used for Simultaneous Analysis of Combined Antihypertensive Medications.

    PubMed

    Mohamed, Heba M; Lamie, Nesrine T

    2016-09-01

    In the past few decades the analytical community has been focused on eliminating or reducing the usage of hazardous chemicals and solvents, in different analytical methodologies, that have been ascertained to be extremely dangerous to human health and environment. In this context, environmentally friendly, green, or clean practices have been implemented in different research areas. This study presents a greener alternative of conventional RP-HPLC methods for the simultaneous determination and quantitative analysis of a pharmaceutical ternary mixture composed of telmisartan, hydrochlorothiazide, and amlodipine besylate, using an ecofriendly mobile phase and short run time with the least amount of waste production. This solvent-replacement approach was feasible without compromising method performance criteria, such as separation efficiency, peak symmetry, and chromatographic retention. The greenness profile of the proposed method was assessed and compared with reported conventional methods using the analytical Eco-Scale as an assessment tool. The proposed method was found to be greener in terms of usage of hazardous chemicals and solvents, energy consumption, and production of waste. The proposed method can be safely used for the routine analysis of the studied pharmaceutical ternary mixture with a minimal detrimental impact on human health and the environment.

  13. Fingerprint chromatogram analysis of extracts from the leaves of Tripterygium wilfordii Hook. F. by high performance liquid chromatography.

    PubMed

    Li, Ke; Wang, Shudong

    2005-05-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the study of fingerprint chromatograms of extracts from the leaves of Tripterygium wilfordii Hook. F. (TWHF) and for controlling the quality of the herb. HPLC separation of the extracts was performed on a Lichrospher RP-18 column and detected by ultraviolet absorbance at 210 nm. The column temperature was maintained at 35 degrees C. A mobile phase composed of acetonitrile:H2O in the ratio of 39:61 (v/v) was found to be most suitable for this separation at a flow rate of 0.8 mL/min with isocratic elution. Under the chromatographic conditions described, the peak profile of the 10 components collected within 35 min made up the fingerprint of the extracts from leaves of TWHF with universal features. The fingerprint chromatograms had a good stability, precision, and reproducibility. The similarity of the extracts from leaves of TWHF collected in summer and winter was studied with triptolide as a reference peak. The method is suitable for differentiation of extracts from the leaves of TWHF, and can be used as a quality control method for this herb.

  14. Development and optimisation of an HPLC-DAD-ESI-Q-ToF method for the determination of phenolic acids and derivatives.

    PubMed

    Restivo, Annalaura; Degano, Ilaria; Ribechini, Erika; Colombini, Maria Perla

    2014-01-01

    A method for the HPLC-MS/MS analysis of phenols, including phenolic acids and naphtoquinones, using an amide-embedded phase column was developed and compared to the literature methods based on classical C18 stationary phase columns. RP-Amide is a recently developed polar embedded stationary phase, whose wetting properties mean that up to 100% water can be used as an eluent. The increased retention and selectivity for polar compounds and the possibility of working in 100% water conditions make this column particularly interesting for the HPLC analysis of phenolic acids and derivatives. In this study, the chromatographic separation was optimised on an HPLC-DAD, and was used to separate 13 standard phenolic acids and derivatives. The method was validated on an HPLC-ESI-Q-ToF. The acquisition was performed in negative polarity and MS/MS target mode. Ionisation conditions and acquisition parameters for the Q-ToF detector were investigated by working on collision energies and fragmentor potentials. The performance of the method was fully evaluated on standards. Moreover, several raw materials containing phenols were analysed: walnut, gall, wine, malbec grape, French oak, red henna and propolis. Our method allowed us to characterize the phenolic composition in a wide range of matrices and to highlight possible matrix effects.

  15. Ultrafast UPLC-ESI-MS and HPLC with monolithic column for determination of principal flavor compounds in vanilla pods.

    PubMed

    Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P

    2009-10-01

    In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.

  16. High-performance liquid chromatographic analysis of as-synthesised N,N'-dimethylformamide-stabilised gold nanoclusters product

    NASA Astrophysics Data System (ADS)

    Xie, Shunping; Paau, Man Chin; Zhang, Yan; Shuang, Shaomin; Chan, Wan; Choi, Martin M. F.

    2012-08-01

    Reverse-phase high-performance liquid chromatographic (RP-HPLC) separation and analysis of polydisperse water-soluble gold nanoclusters (AuNCs) stabilised with N,N'-dimethylformamide (DMF) were investigated. Under optimal elution gradient conditions, the separation of DMF-AuNCs was monitored by absorption and fluorescence spectroscopy. The UV-vis spectral characteristics of the separated DMF-AuNCs have been captured and they do not possess distinct surface plasmon resonance bands, indicating that all DMF-AuNCs are small AuNCs. The photoluminescence emission spectra of the separated DMF-AuNCs are in the blue-light region. Moreover, cationic DMF-AuNCs are for the first time identified by ion chromatography. Our proposed RP-HPLC methodology has been successfully applied to separate AuNCs of various Au atoms as well as DMF-stabilised ligands. Finally, the composition of the separated DMF-AuNCs was confirmed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry and electrospray ionisation mass spectrometry, proving that the as-synthesised DMF-AuNCs product consists of Au10+, Au10, Au11, Au12, Au13, and Au14 NCs stabilised with various numbers of DMF ligands.Reverse-phase high-performance liquid chromatographic (RP-HPLC) separation and analysis of polydisperse water-soluble gold nanoclusters (AuNCs) stabilised with N,N'-dimethylformamide (DMF) were investigated. Under optimal elution gradient conditions, the separation of DMF-AuNCs was monitored by absorption and fluorescence spectroscopy. The UV-vis spectral characteristics of the separated DMF-AuNCs have been captured and they do not possess distinct surface plasmon resonance bands, indicating that all DMF-AuNCs are small AuNCs. The photoluminescence emission spectra of the separated DMF-AuNCs are in the blue-light region. Moreover, cationic DMF-AuNCs are for the first time identified by ion chromatography. Our proposed RP-HPLC methodology has been successfully applied to separate AuNCs of various Au atoms as well as DMF-stabilised ligands. Finally, the composition of the separated DMF-AuNCs was confirmed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry and electrospray ionisation mass spectrometry, proving that the as-synthesised DMF-AuNCs product consists of Au10+, Au10, Au11, Au12, Au13, and Au14 NCs stabilised with various numbers of DMF ligands. This article was submitted as part of a Themed Issue on metallic clusters. Other papers on this topic can be found in issue 14 of vol. 4 (2012). This issue can be found from the Nanoscale homepage [http://www.rsc.org/nanoscale].

  17. Pressurized planar electrochromatography, high-performance thin-layer chromatography and high-performance liquid chromatography--comparison of performance.

    PubMed

    Płocharz, Paweł; Klimek-Turek, Anna; Dzido, Tadeusz H

    2010-07-16

    Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 microm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones. 2010 Elsevier B.V. All rights reserved.

  18. Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on-line solid-phase extraction technique.

    PubMed

    Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori

    2011-07-01

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Influence of variation in mobile phase pH and solute pK(a) with the change of organic modifier fraction on QSRRs of hydrophobicity and RP-HPLC retention of weakly acidic compounds.

    PubMed

    Han, Shu-ying; Liang, Chao; Zou, Kuan; Qiao, Jun-qin; Lian, Hong-zhen; Ge, Xin

    2012-11-15

    The variation in mobile phase pH and ionizable solute dissociation constant (pK(a)) with the change of organic modifier fraction in hydroorganic mobile phase has seemingly been a troublesome problem in studies and applications of reversed phase high performance liquid chromatography (RP-HPLC). Most of the early studies regarding the RP-HPLC of acid-base compounds have to measure the actual pH of the mixed mobile phase rigorously, sometimes bringing difficulties in the practices of liquid chromatographic separation. In this paper, the effect of this variation on the apparent n-octanol/water partition coefficient (K(ow)″) and the related quantitative structure-retention relationship (QSRR) of logK(ow)″ vs. logk(w), the logarithm of retention factor of analytes in neat aqueous mobile phases, was investigated for weakly acidic compounds. This QSRR is commonly used as a classical method for K(ow) measurement by RP-HPLC. The theoretical and experimental derivation revealed that the variation in mobile phase pH and solute pK(a) will not affect the QSRRs of acidic compounds. This conclusion is proved to be suitable for various types of ion-suppressors, i.e., strong acid (perchloric acid), weak acid (acetic acid) and buffer salt (potassium dihydrogen phosphate/phosphoric acid, PBS). The QSRRs of logK(ow)″ vs. logk(w) were modeled by 11 substituted benzoic acids using different types of ion-suppressors in a binary methanol-water mobile phase to confirm our deduction. Although different types of ion-suppressor all can be used as mobile phase pH modifiers, the QSRR model obtained by using perchloric acid as the ion-suppressor was found to have the best result, and the slightly inferior QSRRs were obtained by using acetic acid or PBS as the ion-suppressor. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. A rapid stability-indicating, fused-core HPLC method for simultaneous determination of β-artemether and lumefantrine in anti-malarial fixed dose combination products

    PubMed Central

    2013-01-01

    Background Artemisinin-based fixed dose combination (FDC) products are recommended by World Health Organization (WHO) as a first-line treatment. However, the current artemisinin FDC products, such as β-artemether and lumefantrine, are inherently unstable and require controlled distribution and storage conditions, which are not always available in resource-limited settings. Moreover, quality control is hampered by lack of suitable analytical methods. Thus, there is a need for a rapid and simple, but stability-indicating method for the simultaneous assay of β-artemether and lumefantrine FDC products. Methods Three reversed-phase fused-core HPLC columns (Halo RP-Amide, Halo C18 and Halo Phenyl-hexyl), all thermostated at 30°C, were evaluated. β-artemether and lumefantrine (unstressed and stressed), and reference-related impurities were injected and chromatographic parameters were assessed. Optimal chromatographic parameters were obtained using Halo RP-Amide column and an isocratic mobile phase composed of acetonitrile and 1mM phosphate buffer pH 3.0 (52:48; V/V) at a flow of 1.0 ml/min and 3 μl injection volume. Quantification was performed at 210 nm and 335 nm for β-artemether and for lumefantrine, respectively. In-silico toxicological evaluation of the related impurities was made using Derek Nexus v2.0®. Results Both β-artemether and lumefantrine were separated from each other as well as from the specified and unspecified related impurities including degradants. A complete chromatographic run only took four minutes. Evaluation of the method, including a Plackett-Burman robustness verification within analytical QbD-principles, and real-life samples showed the method is suitable for quantitative assay purposes of both active pharmaceutical ingredients, with a mean recovery relative standard deviation (± RSD) of 99.7 % (± 0.7%) for β-artemether and 99.7 % (± 0.6%) for lumefantrine. All identified β-artemether-related impurities were predicted in Derek Nexus v2.0® to have toxicity risks similar to β-artemether active pharmaceutical ingredient (API) itself. Conclusions A rapid, robust, precise and accurate stability-indicating, quantitative fused-core isocratic HPLC method was developed for simultaneous assay of β-artemether and lumefantrine. This method can be applied in the routine regulatory quality control of FDC products. The in-silico toxicological investigation using Derek Nexus® indicated that the overall toxicity risk for β-artemether-related impurities is comparable to that of β-artemether API. PMID:23631682

  1. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    PubMed

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  2. Resolution and isolation of enantiomers of (±)-isoxsuprine using thin silica gel layers impregnated with L-glutamic acid, comparison of separation of its diastereomers prepared with chiral derivatizing reagents having L-amino acids as chiral auxiliaries.

    PubMed

    Bhushan, Ravi; Nagar, Hariom

    2015-03-01

    Thin silica gel layers impregnated with optically pure l-glutamic acid were used for direct resolution of enantiomers of (±)-isoxsuprine in their native form. Three chiral derivatizing reagents, based on DFDNB moiety, were synthesized having l-alanine, l-valine and S-benzyl-l-cysteine as chiral auxiliaries. These were used to prepare diastereomers under microwave irradiation and conventional heating. The diastereomers were separated by reversed-phase high-performance liquid chromatography on a C18 column with detection at 340 nm using gradient elution with mobile phase containing aqueous trifluoroacetic acid and acetonitrile in different compositions and by thin-layer chromatography (TLC) on reversed phase (RP) C18 plates. Diastereomers prepared with enantiomerically pure (+)-isoxsuprine were used as standards for the determination of the elution order of diastereomers of (±)-isoxsuprine. The elution order in the experimental study of RP-TLC and RP-HPLC supported the developed optimized structures of diastereomers based on density functional theory. The limit of detection was 0.1-0.09 µg/mL in TLC while it was in the range of 22-23 pg/mL in HPLC and 11-13 ng/mL in RP-TLC for each enantiomer. The conditions of derivatization and chromatographic separation were optimized. The method was validated for accuracy, precision, limit of detection and limit of quantification. Copyright © 2014 John Wiley & Sons, Ltd.

  3. RP-HPLC method with electrochemical detection for the determination of metoclopramide in serum and its use in pharmacokinetic studies.

    PubMed

    Lamparczyk, H; Chmielewska, A; Konieczna, L; Plenis, A; Zarzycki, P K

    2001-12-01

    A rapid and sensitive reversed-phase high performance liquid chromatographic method has been developed for the determination of metoclopramide in serum. The assay was performed after single extraction with ethyl ether using methyl parahydroxybenzoate as internal standard. Chromatographic separations were performed on C(18) stationary phase with a mobile phase composed of methanol-phosphate buffer pH 3 (30:70 v/v). Analytes were detected electrochemically. The quantification limit for metoclopramide in serum was 2 ng mL(-1). Linearity of the method was confirmed in the range of 5-120 ng mL(-1) (correlation coefficient 0.9998). Within-day relative standard deviations (RSDs) ranged from 0.3 to 5.5% and between-day RSDs from 0.8 to 6.0%. The analytical method was successfully applied for the determination of pharmacokinetic parameters after ingestion of 10 mg dose of metoclopramide. Studies were performed on 18 healthy volunteers of both sexes. Copyright 2001 John Wiley & Sons, Ltd.

  4. Three-step HPLC-ESI-MS/MS procedure for screening and identifying non-target flavonoid derivatives

    NASA Astrophysics Data System (ADS)

    Rak, Gábor; Fodor, Péter; Abrankó, László

    2010-02-01

    A three-step HPLC-ESI-MS/MS procedure is designed for screening and identification of non-target flavonoid derivatives of selected flavonoid aglycones. In this method the five commonly appearing aglycones (apigenin, luteolin, myricetin, naringenin and quercetin) were selected. The method consists of three individual mass spectrometric experiments of which the first two were implemented within a single chromatographic acquisition. The third step was carried out during a replicate chromatographic run using the same RP-HPLC conditions. The first step, a multiple reaction monitoring (MRM) scan of the aglycones was performed to define the number of derivatives relating to the selected aglycones. For this purpose the characteristic aglycone parts of the unknowns were used as specific tags of the molecules, which were generated as in-source fragments. Secondly, a full scan MS experiment is performed to identify the masses of the potential derivatives of the selected aglycones. Finally, the third step had the capability to confirm the supposed derivatives. The developed method was applied to a commercially available black currant juice to demonstrate its capability to detect and identify various flavonoid glycosides without any preliminary information about their presence in the sample. As a result 13 compounds were detected and identified in total. Namely, 3 different myricetin glycosides and the myricetin aglycone 2 luteolin glycosides plus the aglycone and 3 quercetin glycosides plus the aglycone could be identified from the tested black currant sample. In the case of apigenin and naringenin only the aglycones could be detected.

  5. Sorption of certain isatins on various sorbents under RP-HPLC conditions

    NASA Astrophysics Data System (ADS)

    Konstantinov, A. V.; Shafigulin, R. V.; Il'in, M. M.; Davankov, V. A.; Bulanova, A. V.; Purygin, P. P.

    2013-06-01

    The results from chromatographic analysis of biologically active isatin derivatives on hyper-crosslinked polystyrene (HCLPS) and silica gel modified by octadecyl groups (SilC18) are presented. The constants of distribution of sorbates between a mobile phase and the investigated sorbents ( K x ) and the changes in the standard differential molar Gibbs energies of adsorption (Δ _a bar G^circ ) are calculated, along with the chromatographic retention-physicochemical property of sorbate dependences. It is found that the equations describing these dependences have high forecasting ability with respect to the values of retention factors of the investigated sorbates.

  6. Development and validation of a high performance liquid chromatographic method for simultaneous determination of vitamins A and D3 in fluid milk products.

    PubMed

    Chen, Yang; Reddy, Ravinder M; Li, Wenjing; Yettlla, Ramesh R; Lopez, Salvador; Woodman, Michael

    2015-01-01

    An HPLC method for simultaneous determination of vitamins A and D3 in fluid milk was developed and validated. Saponification and extraction conditions were studied for optimum recovery and simplicity. An RP HPLC system equipped with a C18 column and diode array detector was used for quantitation. The method was subjected to a single-laboratory validation using skim, 2% fat, and whole milk samples at concentrations of 50, 100, and 200% of the recommended fortification levels for vitamins A and D3 for Grade "A" fluid milk. The method quantitation limits for vitamins A and D3 were 0.0072 and 0.0026 μg/mL, respectively. Average recoveries between 94 and 110% and SD values ranging from 2.7 to 6.9% were obtained for both vitamins A and D3. The accuracy of the method was evaluated using a National Institute of Standards and Technology standard reference material (1849a) and proficiency test samples.

  7. Development and Optimisation of an HPLC-DAD-ESI-Q-ToF Method for the Determination of Phenolic Acids and Derivatives

    PubMed Central

    Restivo, Annalaura; Degano, Ilaria; Ribechini, Erika; Colombini, Maria Perla

    2014-01-01

    A method for the HPLC-MS/MS analysis of phenols, including phenolic acids and naphtoquinones, using an amide-embedded phase column was developed and compared to the literature methods based on classical C18 stationary phase columns. RP-Amide is a recently developed polar embedded stationary phase, whose wetting properties mean that up to 100% water can be used as an eluent. The increased retention and selectivity for polar compounds and the possibility of working in 100% water conditions make this column particularly interesting for the HPLC analysis of phenolic acids and derivatives. In this study, the chromatographic separation was optimised on an HPLC-DAD, and was used to separate 13 standard phenolic acids and derivatives. The method was validated on an HPLC-ESI-Q-ToF. The acquisition was performed in negative polarity and MS/MS target mode. Ionisation conditions and acquisition parameters for the Q-ToF detector were investigated by working on collision energies and fragmentor potentials. The performance of the method was fully evaluated on standards. Moreover, several raw materials containing phenols were analysed: walnut, gall, wine, malbec grape, French oak, red henna and propolis. Our method allowed us to characterize the phenolic composition in a wide range of matrices and to highlight possible matrix effects. PMID:24551158

  8. [Simultaneous determination of four common nonprotein nitrogen substances in urine by high performance liquid chromatography].

    PubMed

    Ma, Yuhua; Huang, Dongqun; Zhang, Rui; Xu, Shiru; Feng, Shun

    2013-11-01

    A high performance liquid chromatographic (HPLC) method was proposed to simultaneously determine four common nonprotein nitrogen substances, including creatine (Cr), creatinine (Cn), uric acid (Ua) and pseudouridine (Pu) in urine. After proteins being removed by acetone precipitation method, freeze drying and redissolving, the urine samples were analyzed by HPLC. Chromatographic separation was performed on a Waters RP18 Column (150 mm x 4.60 mm, 3.5 microm) in gradient elution mode using 10.0 mmol/L KH2PO4 solution (pH 4.78) and acetonitrile as mobile phases at a flow rate of 0.8 mL/min. The samples were detected at 220 nm. Rapid separation was achieved within 7 min. Under the optimized conditions, good linearities of four common nonprotein nitrogen substances were obtained in the range of 0.1-250 mg/L. The detection limits were 9.31 (Cr), 26.19 (Cn), 4.70 (Ua), an 6.30 (Pu) microg/L and the recoveries were in the range of 81%-111% with the relative standar deviations of 0.23%-2.78% (n = 3). The results demonstrate that this method is simple, rapid and accurate with good reproducibility, and can provide early diagnosis and preliminary judgment for type 2 diabetes mellitus (T2DM) patients with renal damage.

  9. A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form.

    PubMed

    Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin

    2017-01-01

    A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.

  10. [Direct determination of purine bases in tea by reversed-phase high performance liquid chromatography].

    PubMed

    Ding, M; Yang, H; Xiao, S; Chen, P

    1999-09-01

    A reversed-phase high performance liquid chromatographic(RP-HPLC) method for the direct determination of three purine bases(theobromin, theophyllin and caffeine) in tea was developed. An ODS column with Zorbax SB-C18(4.6 mm i.d. x 250 mm, 5 microns) was employed. The aqueous solution of methanol containing 0.05% of acetic acid and 0.25% of N,N-dimethylformamide(DMF) was used as eluent with a flow rate of 0.8 mL/min. In this method, the aqueous extract of tea can be injected into HPLC directly, but in current HPLC methods for purine bases the coexisted tea polyphenols must be pre-separated. The three purine bases in tea were separated without any interference from the coexisted tea polyphenols. This method is simple (without any special sample pretreatment) and sensitive with detection limits (S/N = 3) of 0.7, 0.9 and 1.8 mg/L for theobromin, theophyllin and caffeine respectively. The linear range of the calibration curve of peak area for the three purine bases were from 6 mg/L to 1,000 mg/L with a correlation coefficient (r) of 0.998-0.999.

  11. Development and validation of polar RP-HPLC method for screening for ectoine high-yield strains in marine bacteria with green chemistry.

    PubMed

    Chen, Jun; Chen, Jianwei; Wang, Sijia; Zhou, Guangmin; Chen, Danqing; Zhang, Huawei; Wang, Hong

    2018-04-02

    A novel, green, rapid, and precise polar RP-HPLC method has been successfully developed and screened for ectoine high-yield strain in marine bacteria. Ectoine is a polar and extremely useful solute which allows microorganisms to survive in extreme environmental salinity. This paper describes a polar-HPLC method employed polar RP-C18 (5 μm, 250 × 4.6 mm) using pure water as the mobile phase and a column temperature of 30 °C, coupled with a flow rate at 1.0 mL/min and detected under a UV detector at wavelength of 210 nm. Our method validation demonstrates excellent linearity (R 2  = 0.9993), accuracy (100.55%), and a limit of detection LOQ and LOD of 0.372 and 0.123 μgmL -1 , respectively. These results clearly indicate that the developed polar RP-HPLC method for the separation and determination of ectoine is superior to earlier protocols.

  12. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  13. Development and validation of liquid chromatographic and UV derivative spectrophotometric methods for the determination of famciclovir in pharmaceutical dosage forms.

    PubMed

    Srinubabu, Gedela; Sudharani, Batchu; Sridhar, Lade; Rao, Jvln Seshagiri

    2006-06-01

    A high-performance liquid chromatographic method and a UV derivative spectrophotometric method for the determination of famciclovir, a highly active antiviral agent, in tablets were developed in the present work. The various parameters, such as linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. HPLC was carried out by using the reversed-phase technique on an RP-18 column with a mobile phase composed of 50 mM monobasic phosphate buffer and methanol (50 : 50; v/v), adjusted to pH 3.05 with orthophosphoric acid. The mobile phase was pumped at a flow rate of 1 ml/min and detection was made at 242 nm with UV dual absorbance detector. The first derivative UV spectrophotometric method was performed at 226.5 nm. Statistical analysis was done by Student's t-test and F-test, which showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and therefore can be used for its Intended purpose.

  14. Isolation and purification of two antioxidant peptides from alcalase hydrolysate of Arca subcrenata.

    PubMed

    Li, Ting-Fei; Ye, Bin; Song, Li-Yan; Yu, Rong-Min

    2014-07-01

    To investigate the constituents with antioxidant activities from alcalase hydrolysate of Arca subcrenata. The consecutive chromatographic methods were employed,including ion-exchange chromatography, gel filtration chromatography, and reverse phase high-performance liquid chromatography (RP-HPLC). The amino acid sequences of the purified antioxidant peptides were determined by automated Edman degradation. Under the guidance of the assay of scavenging free radicals, two peptides with antioxidant activities, termed as A-Bg1 and A-Bh, were isolated and purified from the alcalase hydrolysate of Arca subcrenata. Constituents from the hydrolysate of Arca subcrenata might be a new potential resource of antioxidants.

  15. Separation and quantification of 15 carotenoids by reversed phase high performance liquid chromatography coupled to diode array detection with isosbestic wavelength approach.

    PubMed

    Mitrowska, Kamila; Vincent, Ursula; von Holst, Christoph

    2012-04-13

    The manuscript presents the development of a new reverse phase high performance liquid chromatography (RP-HPLC) photo diode array detection method allowing the separation and quantification of 15 carotenoids (adonirubin, adonixanthin, astaxanthin, astaxanthin dimethyl disuccinate, asteroidenone, beta-apo-8'-carotenal, beta-apo-8'-carotenoic acid ethyl ester, beta-carotene, canthaxanthin, capsanthin, citranaxanthin, echinenone, lutein, lycopene, and zeaxanthin), 10 of which are feed additives authorised within the European Union. The developed method allows for the reliable determination of the total carotenoid content in one run using the corresponding E-isomer as calibration standard while taking into account the E/Z-isomers composition. This is a key criterion for the application of the method, since for most of the analytes included in this study analytical standards are only available for the E-isomers. This goal was achieved by applying the isosbestic concept, in order to identify specific wavelengths, at which the absorption coefficients are identical for all stereoisomers concerned. The second target referred to the optimisation of the LC conditions. By means of an experimental design, an optimised RP-HPLC method was developed allowing for a sufficient chromatographic separation of all carotenoids. The selected method uses a Suplex pKb-100 HPLC column and applying a gradient with a mixture of acetonitrile, tert-butyl-methyl ether and water as mobile phases. The limits of detection and limits of quantification ranged from 0.06 mg L(-1) to 0.14 mg L(-1) and from 0.20 mg L(-1) to 0.48 mg L(-1), respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Simultaneous quantification of delta-9-THC, THC-acid A, CBN and CBD in seized drugs using HPLC-DAD.

    PubMed

    Ambach, Lars; Penitschka, Franziska; Broillet, Alain; König, Stefan; Weinmann, Wolfgang; Bernhard, Werner

    2014-10-01

    An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN). Copyright © 2014. Published by Elsevier Ireland Ltd.

  17. [RP-HPLC method for determination of protopine in plasma and pharmacokinetics in rats].

    PubMed

    Yang, D L; Huang, X N; Sun, A S; Huang, B; Ye, L; Shi, J S

    2001-10-01

    To develop a reversed phase high performance liquid chromatographic method (RP-HPLC) for determination of protopine (Pro) in rat plasma and to investigate the pharmacokinetics of Pro in rats. The column was packed with 5 microns C18. The mobile phase (pH 5.6) was a mixture of methanol-water-10% acetic acid (80:20:2). After twice extracted with ether under basic condition, and reextracted with 0.02 mol.L-1 sulfuric acid, protopine in the plasma samples was isolated well. The content of protopine in the plasma sample was measured by UV detector at 285 nm. The lowest limit of detection was 50 ng.mL-1. The intraday and interday precisions were 1.5%-3.0% and 2.1%-6.2%, respectively. The mean recovery was 80.6%-97.6%. A good linear relationship between the peak height and the concentration of protopine in rat plasma was observed. The pharmacokinetics of protopine had been investigated in rats after intravenous administration 10 mg.kg-1. The concentration-time curve of protopine in rat was confirmed to two-compartment open model. The T1/2 alpha, T1/2 beta, Ke, CL, Vd were 0.05 h, 1.85 h, 1.52 h, 6.41 L.h-1 and 17.27 L, respectively. This method is suitable for studies on pharmacokinetics of protopine.

  18. RP-HPLC method development and validation for simultaneous estimation of atorvastatin calcium and pioglitazone hydrochloride in pharmaceutical dosage form.

    PubMed

    Peraman, Ramalingam; Mallikarjuna, Sasikala; Ammineni, Pravalika; Kondreddy, Vinod kumar

    2014-10-01

    A simple, selective, rapid, precise and economical reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for simultaneous estimation of atorvastatin calcium (ATV) and pioglitazone hydrochloride (PIO) from pharmaceutical formulation. The method is carried out on a C8 (25 cm × 4.6 mm i.d., 5 μm) column with a mobile phase consisting of acetonitrile (ACN):water (pH adjusted to 6.2 using o-phosphoric acid) in the ratio of 45:55 (v/v). The retention time of ATV and PIO is 4.1 and 8.1 min, respectively, with the flow rate of 1 mL/min with diode array detector detection at 232 nm. The linear regression analysis data from the linearity plot showed good linear relationship with a correlation coefficient (R(2)) value for ATV and PIO of 0.9998 and 0.9997 in the concentration range of 10-80 µg mL(-1), respectively. The relative standard deviation for intraday precision has been found to be <2.0%. The method is validated according to the ICH guidelines. The developed method is validated in terms of specificity, selectivity, accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for simultaneous estimation of these drugs in marketed dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Advantages of automation in plasma sample preparation prior to HPLC/MS/MS quantification: application to the determination of cilazapril and cilazaprilat in a bioequivalence study.

    PubMed

    Kolocouri, Filomila; Dotsikas, Yannis; Apostolou, Constantinos; Kousoulos, Constantinos; Soumelas, Georgios-Stefanos; Loukas, Yannis L

    2011-01-01

    An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.

  20. [Studies on HPLC chromatogram of phenolic constituents of Cortex Magnoliae Officinalis].

    PubMed

    Huang, Wen-hua; Guo, Bao-lin; Si, Jin-ping

    2005-07-01

    To study the chemical characteristic, to identify the different forms and to establish the new standard for the quality control of Cortex Magnoliae Officinalis. HPLC method was used with acetonitrile-water (63:37) as the mobile phase at room temperature. The chromatographic column was Lichrospher 100 RP-18e (4.6 mm x 250 mm, 5 microm). The flow rate was 1 mL x min(-1), and the detection wavelength was 294 nm. The chromatograms of 45 individuals from 13 seed resources of Cortex Magnolia Officinalis were recorded. The chemical characteristics analysis and comparability' s calculation of seed resources were made. It was proposed that the area ratio of peak 5 to 6 (characteristic I) and the area ratio of peak 5 and 6 to the total peak areas (characteristic II) are the identification characteristics for different seed resources of Cortex Magnoliae Officinalis. This method can be used effectively to identify the high quality seed resource of Cortex Magnoliae Officinalis.

  1. A HPLC method for the quantification of butyramide and acetamide at ppb levels in hydrogeothermal waters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gracy Elias; Earl D. Mattson; Jessica E. Little

    A quantitative analytical method to determine butyramide and acetamide concentrations at the low ppb levels in geothermal waters has been developed. The analytes are concentrated in a preparation step by evaporation and analyzed using HPLC-UV. Chromatographic separation is achieved isocratically with a RP C-18 column using a 30 mM phosphate buffer solution with 5 mM heptane sulfonic acid and methanol (98:2 ratio) as the mobile phase. Absorbance is measured at 200 nm. The limit of detection (LOD) for BA and AA were 2.0 {mu}g L{sup -1} and 2.5 {mu}g L{sup -1}, respectively. The limit of quantification (LOQ) for BA andmore » AA were 5.7 {mu}g L{sup -1} and 7.7 {mu}g L{sup -1}, respectively, at the detection wavelength of 200 nm. Attaining these levels of quantification better allows these amides to be used as thermally reactive tracers in low-temperature hydrogeothermal systems.« less

  2. Determination of Natamycin in Turkish Yoghurt.

    PubMed

    Bilgic Alkaya, Dilek; Karalomlu, Ozlem

    2016-01-01

    This study was aimed at developing RP-HPLC method for determination of natamycin in Turkish yoghurt. Chromatographic separation was achieved on a C8 column (150 mm × 4.6 mm × 5 µm) with a mobile phase of methanol : water : acetic acid (12 : 8 : 1 v/v/v), at 1 mL/min flow rate with a detection of 303 nm. Natamycin was spiked into handmade yoghurt samples and used for validation. The method has been fully validated according to ISO 9233-2, 2007 (IDF 140-2, 2007). It was successfully applied to determination of 28 different Turkish yoghurt products. Findings dealing with the presence of natamycin in cheese samples are presented.

  3. Identification of intact high molecular weight glutenin subunits from the wheat proteome using combined liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Lagrain, Bert; Brunnbauer, Markus; Rombouts, Ine; Koehler, Peter

    2013-01-01

    The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS), the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC), and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS isolation, wheat proteins were reduced and extracted from flour with 50% 1-propanol containing 1% dithiothreitol. HMW-GS were then selectively precipitated from the protein mixture by adjusting the 1-propanol concentration to 60%. The composition of the precipitated proteins was first evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Coomassie staining and RP-HPLC with ultraviolet detection. Besides HMW-GS (≥65%), the isolated proteins mainly contained ω5-gliadins. Secondly, the isolated protein fraction was analyzed by liquid chromatography-mass spectrometry. Optimal chromatographic separation of HMW-GS from the other proteins in the isolated fraction was obtained when the mobile phase contained 0.1% trifluoroacetic acid as ion-pairing agent. Individual HMW-GS were then identified by determining their molecular masses from the high-resolution mass spectra and comparing these with theoretical masses calculated from amino acid sequences. Using formic acid instead of trifluoroacetic acid in the mobile phase increased protein peak intensities in the base peak mass chromatogram. This allowed the detection of even traces of other wheat proteins than HMW-GS in the isolated fraction, but the chromatographic separation was inferior with a major overlap between the elution ranges of HMW-GS and ω-gliadins. Overall, the described method allows a rapid assessment of wheat quality through the direct determination of the HMW-GS composition and offers a basis for further top-down proteomics of individual HMW-GS and the entire wheat glutenin fraction.

  4. Identification of Intact High Molecular Weight Glutenin Subunits from the Wheat Proteome Using Combined Liquid Chromatography-Electrospray Ionization Mass Spectrometry

    PubMed Central

    Lagrain, Bert; Brunnbauer, Markus; Rombouts, Ine; Koehler, Peter

    2013-01-01

    The present paper describes a method for the identification of intact high molecular weight glutenin subunits (HMW-GS), the quality determining proteins from the wheat storage proteome. The method includes isolation of HMW-GS from wheat flour, further separation of HMW-GS by reversed-phase high-performance liquid chromatography (RP-HPLC), and their subsequent molecular identification with electrospray ionization mass spectrometry using a quadrupole-time-of-flight mass analyzer. For HMW-GS isolation, wheat proteins were reduced and extracted from flour with 50% 1-propanol containing 1% dithiothreitol. HMW-GS were then selectively precipitated from the protein mixture by adjusting the 1-propanol concentration to 60%. The composition of the precipitated proteins was first evaluated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Coomassie staining and RP-HPLC with ultraviolet detection. Besides HMW-GS (≥65%), the isolated proteins mainly contained ω5-gliadins. Secondly, the isolated protein fraction was analyzed by liquid chromatography-mass spectrometry. Optimal chromatographic separation of HMW-GS from the other proteins in the isolated fraction was obtained when the mobile phase contained 0.1% trifluoroacetic acid as ion-pairing agent. Individual HMW-GS were then identified by determining their molecular masses from the high-resolution mass spectra and comparing these with theoretical masses calculated from amino acid sequences. Using formic acid instead of trifluoroacetic acid in the mobile phase increased protein peak intensities in the base peak mass chromatogram. This allowed the detection of even traces of other wheat proteins than HMW-GS in the isolated fraction, but the chromatographic separation was inferior with a major overlap between the elution ranges of HMW-GS and ω-gliadins. Overall, the described method allows a rapid assessment of wheat quality through the direct determination of the HMW-GS composition and offers a basis for further top-down proteomics of individual HMW-GS and the entire wheat glutenin fraction. PMID:23520527

  5. An Experimental Design Approach for Impurity Profiling of Valacyclovir-Related Products by RP-HPLC

    PubMed Central

    Katakam, Prakash; Dey, Baishakhi; Hwisa, Nagiat T; Assaleh, Fathi H; Chandu, Babu R; Singla, Rajeev K; Mitra, Analava

    2014-01-01

    Abstract Impurity profiling has become an important phase of pharmaceutical research where both spectroscopic and chromatographic methods find applications. The analytical methodology needs to be very sensitive, specific, and precise which will separate and determine the impurity of interest at the 0.1% level. Current research reports a validated RP-HPLC method to detect and separate valacyclovir-related impurities (Imp-E and Imp-G) using the Box-Behnken design approach of response surface methodology. A gradient mobile phase (buffer: acetonitrile as mobile phase A and acetonitrile: methanol as mobile phase B) was used. Linearity was found in the concentration range of 50–150 μg/mL. The mean recovery of impurities was 99.9% and 103.2%, respectively. The %RSD for the peak areas of Imp-E and Imp-G were 0.9 and 0.1, respectively. No blank interferences at the retention times of the impurities suggest the specificity of the method. The LOD values were 0.0024 μg/mL for Imp-E and 0.04 μg/mL for Imp-G and the LOQ values were obtained as 0.0082 μg/mL and 0.136 μg/mL, respectively, for the impurities. The S/N ratios in both cases were within the specification limits. Proper peak shapes and satisfactory resolution with good retention times suggested the suitability of the method for impurity profiling of valacyclovir-related drug substances. PMID:25853072

  6. Analysis of iridoids, secoiridoids and xanthones in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea using LC-MS and RP-HPLC.

    PubMed

    Aberham, Anita; Pieri, Valerio; Croom, Edward M; Ellmerer, Ernst; Stuppner, Hermann

    2011-02-20

    This study presents a new and validated HPLC method for the simultaneous determination of bioactive compounds in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea. The iridoid loganic acid, four secoiridoids and 29 xanthones were separated on a RP-18 column, using aqueous o-phosphoric acid (0.085%, v/v) and acetonitrile as mobile phase. Phytochemical investigation of C. erythraea herb and F. caroliniensis roots resulted into isolation of 25 xanthones and three secoiridoids the structure of which was elucidated by spectroscopic means (NMR, MS and UV). 1,3,8-Trihydroxy-5,6-dimethoxyxanthone, isolated from C. erythraea, turned out to be a novel xanthone. The stability of the analytes was tested by subjecting samples to light, moisture and different temperatures. After six months of storage, decomposition of gentiopicroside and sweroside was observed. The swertiamarin content was nearly unchanged when stored at room temperature or in the refrigerator, but high temperature conditions reduced the content to 85%. In contrast, xanthones were stable under long-term, refrigerated and accelerated conditions. The established chromatographic method has been successfully applied for the quantification of the bioactive compounds in the three plants. The presence and distribution of polyoxygenated xanthones within the three members of the Gentianaceae family and their significance as analytical markers are discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Simultaneous determination of multi drug components Theophylline, Etofylline, Guaiphenesine and Ambroxol Hydrochloride by validated RP-HPLC method in liquid dosage form.

    PubMed

    Jain, Jainendra Kumar; Prakash, M S; Mishra, Rajnish K; Khandhar, Amit P

    2008-04-01

    The RP-HPLC (reverse phase high performance liquid chromatography) method was developed and validated for simultaneous determination of Multi drug components i.e., Theophylline, Etofylline, Guaiphenesine and Ambroxol Hydrochloride in a liquid dosage form. Chromatographic separation of the four drugs was performed on a Hypersil Phenyl BDS (25cmX4.6mm, 5mm). The mobile phase constituted of triethylamine pH 3.0 buffer: methanol (85:15) v/v was delivered at the flow rate 1.5 mL/min. Detection was performed at 235 nm. The peak purity of Theophylline, Etofylline, Guaiphenesine and Ambroxol Hydrochloride were 0.99970, 0.99979, 0.99986 and 0.99949 respectively. Calibration curves were linear with correlation coefficient between 0.99995 to 0.99997 over a concentration range of 5 to 37 microg/mL for Theophylline, 19 to 140 microg/mL for Etofylline, 20 to 149 microg/mL for Guaiphenesine and 6 to 45 microg/mL for Ambroxol hydrochloride. The relative standard deviation (RSD) was found < 2.0%. The percentage recovery was found between the range of 98.6% and 100.5% at three different levels. Robustness and ruggedness were performed and result found within the RSD of 2%. All the parameters of validation were found in the acceptance range of ICH guideline.

  8. Improved method for reliable HMW-GS identification by RP-HPLC and SDS-PAGE in common wheat cultivars

    USDA-ARS?s Scientific Manuscript database

    The accurate identification of alleles for high-molecular weight glutenins (HMW-GS) is critical for wheat breeding programs targeting end-use quality. RP-HPLC methods were optimized for separation of HMW-GS, resulting in enhanced resolution of 1By and 1Dx subunits. Statistically significant differe...

  9. Development and validation of a rapid stability indicating HPLC-method using monolithic stationary phase and two spectrophotometric methods for determination of antihistaminic acrivastine in capsules

    NASA Astrophysics Data System (ADS)

    Gouda, Ayman A.; Hashem, Hisham; Jira, Thomas

    2014-09-01

    Simple, rapid and accurate high performance liquid chromatographic (HPLC) and spectrophotometric methods are described for determination of antihistaminic acrivastine in capsules. The first method (method A) is based on accurate, sensitive and stability indicating chromatographic separation method. Chromolith® Performance RP-18e column, a relatively new packing material consisting of monolithic rods of highly porous silica, was used as stationary phase applying isocratic binary mobile phase of ACN and 25 mM NaH2PO4 pH 4.0 in the ratio of 22.5:77.5 at flow rate of 5.0 mL/min and 40 °C. A diode array detector was used at 254 nm for detection. The elution time of acrivastine was found to be 2.080 ± 0.032. The second and third methods (methods B and C) are based on the oxidation of acrivastine with excess N-bromosuccinimide (NBS) and determination of the unconsumed NBS with, metol-sulphanilic acid (λmax: 520 nm) or amaranth dye (λmax: 530 nm). The reacted oxidant corresponds to the drug content. Beer’s law is obeyed over the concentration range 1.563-50, 2.0-20 and 1.0-10 μg mL-1 for methods A, B and C, respectively. The limits of detection and quantitation were 0.40, 0.292 and 0.113 μg mL-1 and 0.782, 0.973 and 0.376 μg mL-1 for methods A, B and C, respectively. The HPLC method was validated for system suitability, linearity, precision, limits of detection and quantitation, specificity, stability and robustness. Stability tests were done through exposure of the analyte solution for four different stress conditions and the results indicate no interference of degradants with HPLC-method. The proposed methods was favorably applied for determination of acrivastine in capsules formulation. Statistical comparison of the obtained results from the analysis of the studied drug to those of the reported method using t- and F-tests showed no significant difference between them.

  10. Facile quantitation of free thiols in a recombinant monoclonal antibody by reversed-phase high performance liquid chromatography with hydrophobicity-tailored thiol derivatization.

    PubMed

    Welch, Leslie; Dong, Xiao; Hewitt, Daniel; Irwin, Michelle; McCarty, Luke; Tsai, Christina; Baginski, Tomasz

    2018-06-02

    Free thiol content, and its consistency, is one of the product quality attributes of interest during technical development of manufactured recombinant monoclonal antibodies (mAbs). We describe a new, mid/high-throughput reversed-phase-high performance liquid chromatography (RP-HPLC) method coupled with derivatization of free thiols, for the determination of total free thiol content in an E. coli-expressed therapeutic monovalent monoclonal antibody mAb1. Initial selection of the derivatization reagent used an hydrophobicity-tailored approach. Maleimide-based thiol-reactive reagents with varying degrees of hydrophobicity were assessed to identify and select one that provided adequate chromatographic resolution and robust quantitation of free thiol-containing mAb1 forms. The method relies on covalent derivatization of free thiols in denatured mAb1 with N-tert-butylmaleimide (NtBM) label, followed by RP-HPLC separation with UV-based quantitation of native (disulfide containing) and labeled (free thiol containing) forms. The method demonstrated good specificity, precision, linearity, accuracy and robustness. Accuracy of the method, for samples with a wide range of free thiol content, was demonstrated using admixtures as well as by comparison to an orthogonal LC-MS peptide mapping method with isotope tagging of free thiols. The developed method has a facile workflow which fits well into both R&D characterization and quality control (QC) testing environments. The hydrophobicity-tailored approach to the selection of free thiol derivatization reagent is easily applied to the rapid development of free thiol quantitation methods for full-length recombinant antibodies. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Study and development of reversed-phase HPLC systems for the determination of 2-imidazolines in the presence of preservatives in pharmaceutical preparations.

    PubMed

    Antoniou, Constantinos G; Markopoulou, Catherine K; Kouskoura, Maria G; Koundourellis, John E

    2011-01-01

    Different HPLC chromatographic systems were investigated on a C18 ACE 5 pm, 150 x 4.6 mm id column for the determination of tymazoline, tramazoline, and antazoline, with either naphazoline or xylometazoline, in commercial preparations. For the development and optimization of the systems, a Response Surface Method (r=0.925-0.980) was used to illustrate the changes in k as a function of pH values and different salt concentrations. The simultaneous separation of 2-imidazolines was accomplished at 40 degrees C with 0.01 M ammonium acetate-methanol (50+50, v/v, pH 6.0) mobile phase at a flow rate of 1.2 mL/min. In order to deal with the usual coexistence of 2-imidazolines with benzethonium and benzalkonium chloride preservatives, it was necessary to use another chromatographic system, 0.01 M ammonium acetate-methanol (50+50, v/v) mobile phase on a cyano ACE 5 pm, 150 x 4.6 mm id column. As part of a more thorough theoretical investigation, a partial least-squares (PLS) technique was used for modeling the RP-HPLC retention data. The model was based on molecular structure descriptors of the analytes' X variables and on their retention time (Log K) Y. The goodness of fit was estimated by the PLS correlation coefficient (r2) and root mean square error of estimation values, which were 0.994 and 0.0479, respectively.

  12. Development and validation of a novel stability-indicating HPLC method for the simultaneous assay of betamethasone-17-valerate, fusidic acid, potassium sorbate, methylparaben and propylparaben in a topical cream preparation.

    PubMed

    Byrne, Jonathan; Velasco-Torrijos, Trinidad; Reinhardt, Robert

    2014-08-05

    A novel stability-indicating reversed phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous assay of betamethasone-17-valerate, fusidic acid and potassium sorbate as well as methyl- and propylparaben in a topical cream preparation has been developed. A 100mm×3.0mm ID. Ascentis Express C18 column maintained at 30°C and UV detection at 240nm were used. A gradient programme was employed at a flow-rate of 0.75ml/min. Mobile phase A comprised of an 83:17 (v/v) mixture of acetonitrile and methanol and mobile phase B of a 10g/l solution of 85% phosphoric acid in purified water. The method has been validated according to current International Conference on Harmonisation (ICH) guidelines and applied during formulation development and stability studies. The procedure has been shown to be stability-indicating for the topical cream. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. A novel RP-HPLC method for simultaneous determination of potassium sorbate and sodium benzoate in soft drinks using C18-bonded monolithic silica column.

    PubMed

    Can, Nafiz O; Arli, Goksel; Lafci, Yigit

    2011-08-01

    Potassium sorbate and sodium benzoate are food additives that are generally employed for prevention of food spoilage originating from bacteria, molds or yeasts. Although these compounds were generally recognized as safe due to their low risk of acute and chronic toxicity, they have limitations of usage to protect human health. Development and validation of a novel RP-HPLC method, in which a C18-bonded monolithic silica column was used as stationary phase to assay these compounds, is described for the first time. Aliquots of 10 μL of samples were injected into chromatograph and eluted using phosphate buffer (0.025 M, pH 2.0)-water-acetonitrile (50:45:5, v/v/v) solution, which was pumped at the rate of 3.0 mL/min. To sharpen the peaks, 10 mM octylamine was added to the mobile phase. Potassium sorbate and sodium benzoate were detected at about 12(th) and 14(th) min, respectively, and quantified at 230 nm using photodiode array detector. A total of 41 samples were prepared by simply filtering through 0.45 μm filters after sonication, and injected into the system without any pre-treatment steps. Applicability of the method was demonstrated by performing total procedure on samples of different brands and types, and their compliance to official regulations was assessed. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms

    PubMed Central

    Reddy, Sunil Pingili; Babu, K. Sudhakar; Kumar, Navneet; Sekhar, Y. V. V. Sasi

    2011-01-01

    Aim and background: A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. Materials and methods: The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Results: Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Conclusion: The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781462

  15. Chromatographic analysis of salicylic compounds in different species of the genus Salix.

    PubMed

    Pobłocka-Olech, Loretta; van Nederkassel, Anne-Marie; Vander Heyden, Yvan; Krauze-Baranowska, Mirosława; Glód, Daniel; Baczek, Tomasz

    2007-11-01

    The separation of nine phenol glycosides--salicin, salicortin, 2'-acetylsalicortin, populin, tremulacin, salidroside, triandrin, picein and helicin--by normal phase (NP), reversed phase (RP) HPLC techniques and a coupling of NP and RP monolithic silica columns was studied. Among the above nine compounds only five--salicin, populin, tremulacin, salidroside and triandrin--were resolved in an NP system with a mobile phase comprising hexane/isopropanol/methanol (87:12:1, v/v/v). Optimized separation was performed with two coupled monolithic silica columns of different polarity (bare silica and RP-18). The method was applied to verify the presence of salicylic compounds and other phenolic derivatives in the bark of six species from the genus Salix, namely S. purpurea, S. daphnoides clone 1095, S. alba clone 1100, S. triandra, S. viminalis, and S. herbacea. Gradient elution with a mobile phase composed of acetonitrile and water containing 0.05% of trifluoroacetic acid, with increasing acetonitrile concentration from 3% to 48%, was chosen as optimal. For the selective detection of the salicylic compounds, an evaporative light scattering detector was employed along with a UV detector. The differences in the composition of phenols in the different plant materials were confirmed. Additionally, it must be emphasized that for the first time the presence of 2'-acetylsalicortin was revealed in S. alba clone 1100. Furthermore, an SPE-HPLC method was developed for the rapid analysis of the salicin content, analyzed as free and total fraction, in willow barks. The determined concentrations of total salicin varied from 25.4 mg/g in S. alba clone 1100 to 96.47 mg/g in S. daphnoides clone 1095.

  16. Silica-based monolithic column with evaporative light scattering detector for HPLC analysis of bacosides and apigenin in Bacopa monnieri.

    PubMed

    Bhandari, Pamita; Kumar, Neeraj; Singh, Bikram; Singh, Virendra; Kaur, Inderjeet

    2009-08-01

    A high performance liquid chromatographic method using a silica-based monolithic column coupled with evaporative light scattering detector (HPLC-ELSD) was developed and validated for simultaneous quantification of bacosides (bacoside A, bacopaside I, bacoside A(3), bacopaside II, bacopaside X, bacopasaponin C) and apigenin in Bacopa monnieri. The chromatographic resolution was achieved on a Chromolith RP-18 (100x4.6 mm) column with acetonitrile/water (30:70) as mobile phase in isocratic elution at a flow rate of 0.7 mL/min. The drift tube temperature of the ELSD was set to 95 degrees C, and the nitrogen flow rate was 2.0 SLM (standard liter per minute). The calibration curves revealed a good linear relationship (r(2) > 0.9988) within the test ranges. The detection limits (S/N = 3) and the quantification limits (S/N = 10) for the compounds were in the range of 0.54-6.06 and 1.61-18.78 microg/mL, respectively. Satisfactory average recovery was observed in the range of 95.8-99.0%. The method showed good reproducibility for the quantification of these compounds in B. monnieri with intra- and inter-day precision of less than 0.69 and 0.67%, respectively. The validated method was successfully applied to quantify analytes in nine accessions of B. monnieri and thus provides a new basis for overall quality assessment of B. monnieri.

  17. Multivariate optimization and validation of an analytical methodology by RP-HPLC for the determination of losartan potassium in capsules.

    PubMed

    Bonfilio, Rudy; Tarley, César Ricardo Teixeira; Pereira, Gislaine Ribeiro; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim

    2009-11-15

    This paper describes the optimization and validation of an analytical methodology for the determination of losartan potassium in capsules by HPLC using 2(5-1) fractional factorial and Doehlert designs. This multivariate approach allows a considerable improvement in chromatographic performance using fewer experiments, without additional cost for columns or other equipment. The HPLC method utilized potassium phosphate buffer (pH 6.2; 58 mmol L(-1))-acetonitrile (65:35, v/v) as the mobile phase, pumped at a flow rate of 1.0 mL min(-1). An octylsilane column (100 mm x 4.6mm i.d., 5 microm) maintained at 35 degrees C was used as the stationary phase. UV detection was performed at 254 nm. The method was validated according to the ICH guidelines, showing accuracy, precision (intra-day relative standard deviation (R.S.D.) and inter-day R.S.D values <2.0%), selectivity, robustness and linearity (r=0.9998) over a concentration range from 30 to 70 mg L(-1) of losartan potassium. The limits of detection and quantification were 0.114 and 0.420 mg L(-1), respectively. The validated method may be used to quantify losartan potassium in capsules and to determine the stability of this drug.

  18. Development and Validation of an HPLC Method for Simultaneous Determination of Rifampicin, Isoniazid, Pyrazinamide, and Ethambutol Hydrochloride in Pharmaceutical Formulations.

    PubMed

    Chellini, Paula R; Lages, Eduardo B; Franco, Pedro H C; Nogueira, Fernando H A; César, Isabela C; Pianetti, Gerson A

    2015-01-01

    Tuberculosis treatment consists of a fixed dose combination of rifampicin (RIF), isoniazid (INH), pyrazinamide (PYZ), and ethambutol hydrochloride (EMB). The combined treatment using various drugs is necessary for patient curing, without recrudescence, and for prevention of drug-resistant mutants, which may occur during treatment. An HPLC-diode array detector (DAD) method for the simultaneous determination of RIF, INH, PYZ, and EMB in fixed dose combination tablets was developed and validated. Chromatographic experiments were performed on an Agilent 1200 HPLC system, and the separation was carried out on a Purospher STAR RP18e (250×4.6 mm id, 5 μm, Merck) analytical column. Gradient elution was carried out with a mobile phase of 20 mM monobasic sodium phosphate buffer with 0.2% triethylamine (pH 7.0) and acetonitrile at a flow rate of 1.5 mL/min. The total run time was 12 min, and the re-equilibration time was 5 min. EMB detection was performed at 210 nm, and RIF, INH, and PYZ were detected at 238 nm, using a DAD. The method proved to be specific, linear (r2>0.99), precise (RSD<2%), accurate, and robust and may be applied to the QC analysis of pharmaceutical formulations.

  19. Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.

    PubMed

    Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M

    2016-11-01

    Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.

  20. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms.

    PubMed

    Reddy, Sunil Pingili; Babu, K Sudhakar; Kumar, Navneet; Sekhar, Y V V Sasi

    2011-10-01

    A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness.

  1. Complexity in estimation of esomeprazole and its related impurities' stability in various stress conditions in low-dose aspirin and esomeprazole magnesium capsules.

    PubMed

    Reddy, Palavai Sripal; Hotha, Kishore Kumar; Sait, Shakil

    2013-01-01

    A complex, sensitive, and precise high-performance liquid chromatographic method for the profiling of impurities of esomeprazole in low-dose aspirin and esomeprazole capsules has been developed, validated, and used for the determination of impurities in pharmaceutical products. Esomeprazole and its related impurities' development in the presence of aspirin was traditionally difficult due to aspirin's sensitivity to basic conditions and esomeprazole's sensitivity to acidic conditions. When aspirin is under basic, humid, and extreme temperature conditions, it produces salicylic acid and acetic acid moieties. These two byproducts create an acidic environment for the esomeprazole. Due to the volatility and migration phenomenon of the produced acetic acid and salicylic acid from aspirin in the capsule dosage form, esomeprazole's purity, stability, and quantification are affected. The objective of the present research work was to develop a gradient reversed-phase liquid chromatographic method to separate all the degradation products and process-related impurities from the main peak. The impurities were well-separated on a RP8 column (150 mm × 4.6mm, X-terra, RP8, 3.5μm) by the gradient program using a glycine buffer (0.08 M, pH adjusted to 9.0 with 50% NaOH), acetonitrile, and methanol at a flow rate of 1.0 mL min(-1) with detection wavelength at 305 nm and column temperature at 30°C. The developed method was found to be specific, precise, linear, accurate, rugged, and robust. LOQ values for all of the known impurities were below reporting thresholds. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation in the presence of aspirin. The developed RP-HPLC method was validated according to the present ICH guidelines for specificity, linearity, accuracy, precision, limit of detection, limit of quantification, ruggedness, and robustness.

  2. Characterization of new types of stationary phases for fast and ultra-fast liquid chromatography by signal processing based on AutoCovariance Function: a case study of application to Passiflora incarnata L. extract separations.

    PubMed

    Pietrogrande, Maria Chiara; Dondi, Francesco; Ciogli, Alessia; Gasparrini, Francesco; Piccin, Antonella; Serafini, Mauro

    2010-06-25

    In this study, a comparative investigation was performed of HPLC Ascentis (2.7 microm particles) columns based on fused-core particle technology and Acquity (1.7 microm particles) columns requiring UPLC instruments, in comparison with Chromolith RP-18e columns. The study was carried out on mother and vegetal tinctures of Passiflora incarnata L. on one single or two coupled columns. The fundamental attributions of the chromatographic profiles are evaluated using a chemometric procedure, based on the AutoCovariance Function (ACVF). Different chromatographic systems are compared in terms of their separation parameters, i.e., number of total chemical components (m(tot)), separation efficiency (sigma), peak capacity (n(c)), overlap degree of peaks and peak purity. The obtained results show the improvements achieved by HPLC columns with narrow size particles in terms of total analysis time and chromatographic efficiency: comparable performance are achieved by Ascentis (2.7 microm particle) column and Acquity (1.7 microm particle) column requiring UPLC instruments. The ACVF plot is proposed as a simplified tool describing the chromatographic fingerprint to be used for evaluating and comparing chemical composition of plant extracts by using the parameters D% - relative abundance of the deterministic component - and c(EACF) - similarity index computed on ACVF. Copyright 2010 Elsevier B.V. All rights reserved.

  3. Analysis of wax esters by silver-ion high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Vrkoslav, Vladimír; Urbanová, Klára; Háková, Matina; Cvačka, Josef

    2013-08-09

    Wax esters (WEs), esters of long-chain fatty acids and long-chain alcohols, were analysed by Ag-HPLC/APCI-MS/MS. Two ChromSpher Lipids columns connected in series (a total length of 50cm) and hexane-2-propanol-acetonitrile mobile phases were used to achieve good separation of the molecular species. The chromatographic behaviour of WEs was studied under optimised conditions: retention increased with the number of double bonds and with the temperature (15-35°C); retention times were affected by the double-bond position, trans isomers eluted earlier than cis isomers, and the WEs were partially separated depending on the aliphatic-chain length. The WEs provided simple APCI spectra with [M+H](+) ions, the MS/MS spectra showed fragments, which allowed their identification. The method was applied for an analysis of the WE mixtures from jojoba oil and human hair and the results were compared with analogous data from an optimised RP-HPLC system. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Unifying expression scale for peptide hydrophobicity in proteomic reversed phase high-pressure liquid chromatography experiments.

    PubMed

    Grigoryan, Marine; Shamshurin, Dmitry; Spicer, Victor; Krokhin, Oleg V

    2013-11-19

    As an initial step in our efforts to unify the expression of peptide retention times in proteomic liquid chromatography-mass spectrometry (LC-MS) experiments, we aligned the chromatographic properties of a number of peptide retention standards against a collection of peptides commonly observed in proteomic experiments. The standard peptide mixtures and tryptic digests of samples of different origins were separated under the identical chromatographic condition most commonly employed in proteomics: 100 Å C18 sorbent with 0.1% formic acid as an ion-pairing modifier. Following our original approach (Krokhin, O. V.; Spicer, V. Anal. Chem. 2009, 81, 9522-9530) the retention characteristics of these standards and collection of tryptic peptides were mapped into hydrophobicity index (HI) or acetonitrile percentage units. This scale allows for direct visualization of the chromatographic outcome of LC-MS acquisitions, monitors the performance of the gradient LC system, and simplifies method development and interlaboratory data alignment. Wide adoption of this approach would significantly aid understanding the basic principles of gradient peptide RP-HPLC and solidify our collective efforts in acquiring confident peptide retention libraries, a key component in the development of targeted proteomic approaches.

  5. Generation of accurate peptide retention data for targeted and data independent quantitative LC-MS analysis: Chromatographic lessons in proteomics.

    PubMed

    Krokhin, Oleg V; Spicer, Vic

    2016-12-01

    The emergence of data-independent quantitative LC-MS/MS analysis protocols further highlights the importance of high-quality reproducible chromatographic procedures. Knowing, controlling and being able to predict the effect of multiple factors that alter peptide RP-HPLC separation selectivity is critical for successful data collection for the construction of ion libraries. Proteomic researchers have often regarded RP-HPLC as a "black box", while vast amount of research on peptide separation is readily available. In addition to obvious parameters, such as the type of ion-pairing modifier, stationary phase and column temperature, we describe the "mysterious" effects of gradient slope, column size and flow rate on peptide separation selectivity. Retention time variations due to these parameters are governed by the linear solvent strength (LSS) theory on a peptide level by the value of its slope S in the basic LSS equation-a parameter that can be accurately predicted. Thus, the application of shallower gradients, higher flow rates, or smaller columns will each increases the relative retention of peptides with higher S-values (long species with multiple positively charged groups). Simultaneous changes to these parameters that each drive shifts in separation selectivity in the same direction should be avoided. The unification of terminology represents another pressing issue in this field of applied proteomics that should be addressed to facilitate further progress. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Natural deep eutectic solvents as the major mobile phase components in high-performance liquid chromatography-searching for alternatives to organic solvents.

    PubMed

    Sutton, Adam T; Fraige, Karina; Leme, Gabriel Mazzi; da Silva Bolzani, Vanderlan; Hilder, Emily F; Cavalheiro, Alberto J; Arrua, R Dario; Funari, Cristiano Soleo

    2018-06-01

    Over the past six decades, acetonitrile (ACN) has been the most employed organic modifier in reversed-phase high-performance liquid chromatography (RP-HPLC), followed by methanol (MeOH). However, from the growing environmental awareness that leads to the emergence of "green analytical chemistry," new research has emerged that includes finding replacements to problematic ACN because of its low sustainability. Deep eutectic solvents (DES) can be produced from an almost infinite possible combinations of compounds, while being a "greener" alternative to organic solvents in HPLC, especially those prepared from natural compounds called natural DES (NADES). In this work, the use of three NADES as the main organic component in RP-HPLC, rather than simply an additive, was explored and compared to the common organic solvents ACN and MeOH but additionally to the greener ethanol for separating two different mixtures of compounds, one demonstrating the elution of compounds with increasing hydrophobicity and the other comparing molecules of different functionality and molar mass. To utilize NADES as an organic modifier and overcome their high viscosity monolithic columns, temperatures at 50 °C and 5% ethanol in the mobile phase were used. NADES are shown to give chromatographic performances in between those observed for ACN and MeOH when eluotropic strength, resolution, and peak capacity were taken into consideration, while being less environmentally impactful as shown by the HPLC-Environmental Assessment Tool (HPLC-EAT) metric. With the development of proper technologies, DES could open a new class of mobile phases increasing the possibilities of new separation selectivities while reducing the environmental impact of HPLC analyses. Graphical abstract Natural deep eutectic solvents versus traditional solvents in HPLC.

  7. A novel approach for the quantitation of carbohydrates in mash, wort, and beer with RP-HPLC using 1-naphthylamine for precolumn derivatization.

    PubMed

    Rakete, Stefan; Glomb, Marcus A

    2013-04-24

    A novel universal method for the determination of reducing mono-, di-, and oligosaccharides in complex matrices on RP-HPLC using 1-naphthylamine for precolumn derivatization with sodium cyanoborhydride was established to study changes in the carbohydrate profile during beer brewing. Fluorescence and mass spectrometric detection enabled very sensitive analyses of beer-relevant carbohydrates. Mass spectrometry additionally allowed the identification of the molecular weight and thereby the degree of polymerization of unknown carbohydrates. Thus, carbohydrates with up to 16 glucose units were detected. Comparison demonstrated that the novel method was superior to fluorophore-assisted carbohydrate electrophoresis (FACE). The results proved the HPLC method clearly to be more powerful in regard to sensitivity and resolution. Analogous to FACE, this method was designated fluorophore-assisted carbohydrate HPLC (FAC-HPLC).

  8. Development and validation of a fast RP-HPLC method for determination of methotrexate entrapment efficiency in polymeric nanocapsules.

    PubMed

    Sartori, Tatiane; Seigi Murakami, Fabio; Pinheiro Cruz, Ariane; Machado de Campos, Angela

    2008-07-01

    A rapid and effective isocratic chromatographic procedure is successfully developed to determinate methotrexate (MTX) entrapment efficiency (EE) in polymeric nanocapsules using reversed-phase high-performance liquid chromatography. The method employed a RP-C(18) Shimadzu Shim-pack CLC-ODS (150 mm x 4.6 mm, 5 microm) column with mobile phase constituted by a mixture of water-acetonitrile-tetrahydrofuran (65:30:5 v/v/v; pH 3.0) at a flow rate of 0.8 mL/min. The eluate is monitored with a UV detector set at 313 nm. The parameters used in the validation process are: linearity, specificity, precision, accuracy, and limit of quantitation (LOQ). The linearity is evaluated by a calibration curve in the concentration range of 10-50 microg/mL and presented a correlation coefficient of 0.9998. The polymers (PLA or PLA-PEG), oil, and surfactants used in the nanocapsule formulation did not interfere with analysis and the recovery was quantitative. The intra and inter-day assay relative standard deviation were less than 0.72%. Results are satisfactory, and the method proved to be adequate for the determination of methotrexate in nanocapsules formulations.

  9. Measurement of H2S in vivo and in vitro by the monobromobimane method

    PubMed Central

    Shen, Xinggui; Kolluru, Gopi K.; Yuan, Shuai; Kevil, Christopher

    2015-01-01

    The gasotransmitter hydrogen sulfide (H2S) is known as an important regulator in several physiological and pathological responses. Among the challenges facing the field is the accurate and reliable measurement of hydrogen sulfide bioavailability. We have reported an approach to discretely measure sulfide and sulfide pools using the monobromobimane (MBB) method coupled with RP-HPLC. The method involves the derivatization of sulfide with excess MBB under precise reaction conditions at room temperature to form sulfide-dibimane. The resultant fluorescent sulfide-dibimane (SDB) is analyzed by RP-HPLC using fluorescence detection with the limit of detection for SDB (2 nM). Care must be taken to avoid conditions that may confound H2S measurement with this method. Overall, RP-HPLC with fluorescence detection of SDB is a useful and powerful tool to measure biological sulfide levels. PMID:25725514

  10. Measurement of H2S in vivo and in vitro by the monobromobimane method.

    PubMed

    Shen, Xinggui; Kolluru, Gopi K; Yuan, Shuai; Kevil, Christopher G

    2015-01-01

    The gasotransmitter hydrogen sulfide (H2S) is known as an important regulator in several physiological and pathological responses. Among the challenges facing the field is the accurate and reliable measurement of hydrogen sulfide bioavailability. We have reported an approach to discretely measure sulfide and sulfide pools using the monobromobimane (MBB) method coupled with reversed phase high-performance liquid chromatography (RP-HPLC). The method involves the derivatization of sulfide with excess MBB under precise reaction conditions at room temperature to form sulfide dibimane (SDB). The resultant fluorescent SDB is analyzed by RP-HPLC using fluorescence detection with the limit of detection for SDB (2 nM). Care must be taken to avoid conditions that may confound H2S measurement with this method. Overall, RP-HPLC with fluorescence detection of SDB is a useful and powerful tool to measure biological sulfide levels. © 2015 Elsevier Inc. All rights reserved.

  11. Development and validation of a RP-HPLC method for the quantitation of tofacitinib in rat plasma and its application to a pharmacokinetic study.

    PubMed

    S, Vijay Kumar; Dhiman, Vinay; Giri, Kalpesh Kumar; Sharma, Kuldeep; Zainuddin, Mohd; Mullangi, Ramesh

    2015-09-01

    A novel, simple, specific, sensitive and reproducible high-performance liquid chromatography (HPLC) assay method has been developed and validated for the estimation of tofacitinib in rat plasma. The bioanalytical procedure involves extraction of tofacitinib and itraconazole (internal standard, IS) from rat plasma with a simple liquid-liquid extraction process. The chromatographic analysis was performed on a Waters Alliance system using a gradient mobile phase conditions at a flow rate of 1.0 mL/min and C18 column maintained at 40 ± 1 °C. The eluate was monitored using an UV detector set at 287 nm. Tofacitinib and IS eluted at 6.5 and 8.3 min, respectively and the total run time was 10 min. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The calibration curve was linear over a concentration range of 182-5035 ng/mL (r(2) = 0.995). The intra- and inter-day precisions were in the range of 1.41-11.2 and 3.66-8.81%, respectively, in rat plasma. The validated HPLC method was successfully applied to a pharmacokinetic study in rats. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Individual Phosphatidylcholine Species Analysis by RP-HPLC-ELSD for Determination of Polyenylphosphatidylcholine in Lecithins.

    PubMed

    Lee, Wei-Ju; Weng, Shun-Hsiang; Su, Nan-Wei

    2015-04-22

    Polyenylphosphatidylcholine (PPC), a subgroup of the bioactive agents in phosphatidylcholine (PC), has been indicated to possess liver-protective effects. This study aimed to investigate a promising and feasible method to determine PC molecular species with a reverse phase (RP) high-performance liquid chromatograph (HPLC) equipped with an evaporative light scattering detector (ELSD). Chromatography was achieved using a C30 column and an isocratic mobile phase consisting of acetonitrile/methanol/triethylamine (40/58/2, v/v/v) at a flow rate of 1 mL/min, and ELSD detection was performed using 80 °C for the drift tube and an air flow rate of 1.8 L/min. To identify individual peaks on the chromatogram, MALDI-TOF-MS was employed for initial detection, and then the results were used to investigate the relationship between the retention time and fatty acyl chains of each PC molecule. A linear correlation was observed between the retention time and theoretical carbon number (TCN) of individual PC species. The compositions of PC molecular species in soybean and sunflower lecithins were similar to each other, and the major PC molecular species were 1,2-dilinoleoyl-sn-glycero-3-phosphocholine (LLPC), 1-oleoyl-2-linoleoyl-sn-glycero-3-phosphocholine (OLPC), and 1-palmitoyl-2-linoleoyl-sn-glycero-3-phosphocholine (PLPC). The contents of LLPC in soybean PC and sunflower PC were 40.6% and 64.3%, respectively.

  13. Determination of josamycin residues in porcine tissues using high-performance liquid chromatography with pre-column derivatization and spectrofluorimetric detection.

    PubMed

    Leroy, P; Decolin, D; Nicolas, A; Archimbault, P

    1994-12-01

    A simple, selective and sensitive high-performance liquid chromatographic (HPLC) method has been developed for the measurement of josamycin residues in four porcine tissues (i.e., muscle, liver, kidney and fat). The sample preparation consisted of a homogenization step in an acetonitrile-10 mmol l-1 phosphate buffer mixture, pH 6.0 (35 + 65), centrifugation and a liquid-liquid extractive clean-up of the resulting supernatant with isooctane. Pre-column derivatization of josamycin was performed using cyclohexa-1,3-dione in ammonium acetate buffer, pH 5.0 (90 degrees C for 2 h). The derivative was chromatographed in an isocratic reversed-phase HPLC system. A LiChrospher RP 18 end-capped (5 microns) column was eluted with an acetonitrile-methanol-10 mmol l-1 phosphate buffer mixture, pH 6.0 (45 + 5 + 50). The capacity factor of the josamycin derivative was 17.5. Detection was achieved using spectrofluorimetry (lambda ex = 375 nm; lambda em = 450 nm). The structure of the derivative was assessed by using mass spectrometry. Full selectivity was obtained in the HPLC system versus other macrolide antibiotics (tylosin, spiramycin and erythromycin), aldehydes (formaldehyde, acetaldehyde and benzaldehyde) and endogenous compounds. Linearity and repeatability were tested. Correlation coefficients, for calibration curves in the range of 0.1-3.2 micrograms g-1, were greater than 0.999 for all tissues and the relative standard deviation (S(r)) was 4.9% (1.6 micrograms g-1; n = 6); recovery was higher than 88%.

  14. Development and validation of a stability-indicating RP-HPLC method for assay of betamethasone and estimation of its related compounds.

    PubMed

    Fu, Qiang; Shou, Minshan; Chien, Dwight; Markovich, Robert; Rustum, Abu M

    2010-02-05

    Betamethasone (9alpha-fluoro-16beta-methylprednisolone) is one of the members of the corticosteriod family of active pharmaceutical ingredient (API), which is widely used as an anti-inflammatory agent and also as a starting material to manufacture various esters of betamethasone. A stability-indicating reverse-phase high performance liquid chromatography (RP-HPLC) method has been developed and validated which can separate and accurately quantitate low levels of 26 betamethasone related compounds. The stability-indicating capability of the method was demonstrated through adequate separation of all potential betamethasone related compounds from betamethasone and also from each other that are present in aged and stress degraded betamethasone stability samples. Chromatographic separation of betamethasone and its related compounds was achieved by using a gradient elution at a flow rate of 1.0mL/min on a ACE 3 C18 column (150mmx4.6mm, 3microm particle size, 100A pore size) at 40 degrees C. Mobile phase A of the gradient was 0.1% methanesulfonic acid in aqueous solution and mobile phase B was a mixture of tert-butanol and 1,4-dioxane (7:93, v/v). UV detection at 254nm was employed to monitor the analytes. For betamethasone 21-aldehyde, the QL and DL were 0.02% and 0.01% respectively. For betamethasone and the rest of the betamethasone related compounds, the QL and DL were 0.05% and 0.02%. The precision of betamethasone assay is 0.6% and the accuracy of betamethasone assay ranged from 98.1% to 99.9%.

  15. Rapid simultaneous determination of marmelosin, umbelliferone and scopoletin from Aegle marmelos fruit by RP-HPLC.

    PubMed

    Shinde, P B; Katekhaye, S D; Mulik, M B; Laddha, K S

    2014-09-01

    The surge of interest in naturally occurring phytochemicals with high therapeutic potential has led to the discovery of many molecules, out of which naturally occuring coumarins such as marmelosin, umbelliferone and scopoletin present in Aegle marmelos (Bael) fruit shows good therapeutic potential. The aim of the present work is to develop and validate Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method for simultaneous determination of marmelosin, umbelliferone and scopoletin in A. marmelos fruit extracts. The chromatographic separation was performed with isocratic elution of 55:45 (%, v/v) methanol-water containing 0.1 % acetic acid as mobile phase. The method used to analyse the extract of A. marmelos showed good resolution with retention time within 12 min. The relative concentrations of above phytoconstituent were determined in A. marmelos fruits. The method was found to give compact peaks for scopoletin, umbelliferone and marmelosin (Rt of 4.6, 6.5 and 11.3 min respectively) and were linear over the range 5-30 μg ml(-1) (R(2) = 0.9655), 2-10 μg ml(-1) (R(2) = 0.9964) and 2-10 μg ml(-1) (R(2) = 0.9862) respectively. The mean recoveries for marmelosin, umbelliferone and scopoletin at three concentrations were in the range of 98.8-102.9, 98.8-101.1 and 94.2-98.3 % respectively. The relative standard deviation of accuracy, precision and repeatability were within 2 %, indicating the method produced highly reproducible results. Therefore this simple, precise and accurate method enables simultaneous separation of this phytoconstituent and hence can be successfully applied in analysis and routine quality control of herbal material and formulation containing A. marmelos.

  16. Analysis Study of Stevioside and Rebaudioside A from Stevia rebaudiana Bertoni by Normal Phase SPE and RP-HPLC

    NASA Astrophysics Data System (ADS)

    Martono, Y.; Rohman, A.; Riyanto, S.; Martono, S.

    2018-04-01

    Solid Phase Extraction (SPE) method using silica as sorbent for stevioside and rebaudiosida A analysis in Stevia rebaudiana Bertoni leaf have not been performed. The aim of this study is to develop SPE method using silica as sorbent for Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) analysis of stevioside and rebaudiosida A in S. rebaudiana leaf. The results of this study indicate that the optimal conditions for normal phase SPE (silica) are conditioned with 3.0 mL of hexane. The sample loading volume is 0.1 mL. Cartridge is eluted with 1.0 mL acetonitrile: water (80: 20, v/v) to separate both analytes. The cartridge is washed with chloroform and water of 0.3 mL respectively. The developed SPE sample preparation method meets the accuracy and precision test and can be used for the analysis of stevioside and rebaudioside A by RP-HPLC.

  17. Development and Validation of RP-HPLC Method for the Estimation of Ivabradine Hydrochloride in Tablets

    PubMed Central

    Seerapu, Sunitha; Srinivasan, B. P.

    2010-01-01

    A simple, sensitive, precise and robust reverse–phase high-performance liquid chromatographic method for analysis of ivabradine hydrochloride in pharmaceutical formulations was developed and validated as per ICH guidelines. The separation was performed on SS Wakosil C18AR, 250×4.6 mm, 5 μm column with methanol:25 mM phosphate buffer (60:40 v/v), adjusted to pH 6.5 with orthophosphoric acid, added drop wise, as mobile phase. A well defined chromatographic peak of Ivabradine hydrochloride was exhibited with a retention time of 6.55±0.05 min and tailing factor of 1.14 at the flow rate of 0.8 ml/min and at ambient temperature, when monitored at 285 nm. The linear regression analysis data for calibration plots showed good linear relationship with R=0.9998 in the concentration range of 30-210 μg/ml. The method was validated for precision, recovery and robustness. Intra and Inter-day precision (% relative standard deviation) were always less than 2%. The method showed the mean % recovery of 99.00 and 98.55 % for Ivabrad and Inapure tablets, respectively. The proposed method has been successfully applied to the commercial tablets without any interference of excipients. PMID:21695008

  18. High-speed and high-resolution UPLC separation at zero degrees Celsius

    PubMed Central

    Wales, Thomas E.; Fadgen, Keith E.; Gerhardt, Geoff C.; Engen, John R.

    2008-01-01

    The conformational properties of proteins can be probed with hydrogen/deuterium exchange mass spectrometry (HXMS). In order to maintain the deuterium label during LC/MS analyses, chromatographic separation must be done rapidly (usually in under 8–10 minutes) and at zero degrees Celsius. Traditional RP-HPLC with ~3 micron particles has shown generally poor chromatographic performance under these conditions and thereby has been prohibitive for HXMS analyses of larger proteins and many protein complexes. Ultra performance liquid chromatography (UPLC) employs particles smaller than 2 microns in diameter to achieve superior resolution, speed, and sensitivity as compared to HPLC. UPLC has previously been shown to be compatible with the fast separation and low temperature requirements of HXMS. Here we present construction and validation of a custom UPLC system for HXMS. The system is based on the Waters nanoACQUITY platform and contains a Peltier-cooled module that houses the injection and switching valves, online pepsin digestion column, and C-18 analytical separation column. Single proteins in excess of 95 kDa and a four-protein mixture in excess of 250 kDa have been used to validate the performance of this new system. Near baseline resolution was achieved in 6 minute separations at 0 °C and displayed a median chromatographic peak width of ~2.7 sec at half height. Deuterium recovery was similar to that obtained using a conventional HPLC and icebath. This new system represents a significant advancement in HXMS technology that is expected to make the technique more accessible and mainstream in the near future. PMID:18672890

  19. [Identification of impurity peaks in the HPLC chromatogram by LC-MS and two-dimensional chromatographic correlation spectroscopy].

    PubMed

    Chen, Zhen-Zhen; Zhang, Dou-Sheng; Wang, Nan; Feng, Fang; Hu, Chang-Qin

    2012-04-01

    A novel qualitative analytical method by using two-dimensional chromatographic correlation spectroscopy techniques for recognizing impurity peaks of HPLC methods of quality control and LC-MS chromatographic system was established. The structures of major degradation products of ceftizoxime and cefdinir were identified by LC-MS and MassWorks application; the standard chromatographic and spectral data of the degradation impurities were obtained by high-performance liquid chromatography with diode array detection. The impurity peaks of two-dimensional chromatography were matched by comparison of spectra and calculating correlation coefficients. Peaks in chromatography can be identified accurately and rapidly in different chromatographic systems such as column and mobile phase changed. The method provides a new way and thought to identify the peaks in quality control of impurities without reference impurity substances.

  20. [[Chiral separation of five arylpropionic acid drugs and determination of their enantiomers in pharmaceutical preparations by reversed-phase high performance liquid chromatography with cellulose-tris-(4-methylbenzoate) stationary phase

    PubMed

    Luo, An; Wan, Qiang; Fan, Huajun; Chen, Zhi; Wu, Xuehao; Huang, Xiaowen; Zang, Linquan

    2014-09-01

    Chromatographic behaviors for enantiomeric separation of arylpropionic acid drugs were systematically developed by reversed phase-high performance liquid chromatography (RP-HPLC) using cellulose-tris-(4-methylbenzoate) (CTMB) as chiral stationary phase (CSP). The effects of the composition of the mobile phase, additives and temperature on chiral separation of flurbiprofen, pranoprofen, naproxen, ibuprofen and loxoprofen were further investigated. The enantiomers had been successfully separated on CSP of CTMB by the mobile phase of methanol-0.1% (v/v) formic acid except naproxen by acetonitrile-0.1% (v/v) formic acid at 25 °C. The mechanisms of the racemic resolution for the above mentioned five drugs are discussed thermodynamically and structurally. The resolutions between respective enantiomers for arylpropionic acid drugs on CTMB had significant differences due to their chromatographic behaviors. The order of resolutions ranked pranoprofen, loxoprofen, flurbiprofen, ibuprofen and naproxen. The method established has been successfully applied to the determination of the enantiomers of the five drugs in commercial preparations under the optimized conditions. It proved that the method is simple, reliable and accurate.

  1. Sulfanilic acid-modified chitosan mini-spheres and their application for lysozyme purification from egg white.

    PubMed

    Hirsch, Daniela B; Baieli, María F; Urtasun, Nicolás; Lázaro-Martínez, Juan M; Glisoni, Romina J; Miranda, María V; Cascone, Osvaldo; Wolman, Federico J

    2018-03-01

    A cation exchange matrix with zwitterionic and multimodal properties was synthesized by a simple reaction sequence coupling sulfanilic acid to a chitosan based support. The novel chromatographic matrix was physico-chemically characterized by ss-NMR and ζ potential, and its chromatographic performance was evaluated for lysozyme purification from diluted egg white. The maximum adsorption capacity, calculated according to Langmuir adsorption isotherm, was 50.07 ± 1.47 mg g -1 while the dissociation constant was 0.074 ± 0.012 mg mL -1 . The process for lysozyme purification from egg white was optimized, with 81.9% yield and a purity degree of 86.5%, according to RP-HPLC analysis. This work shows novel possible applications of chitosan based materials. The simple synthesis reactions combined with the simple mode of use of the chitosan matrix represents a novel method to purify proteins from raw starting materials. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 34:387-396, 2018. © 2017 American Institute of Chemical Engineers.

  2. Determination of pKa values of nonsteroidal antiinflammatory drug-oxicams by RP-HPLC and their analysis in pharmaceutical dosage forms.

    PubMed

    Demiralay, Ebru Cubuk; Alsancak, Guleren; Ozkan, Sibel A

    2009-09-01

    In this study, pK(a) values were determined by using the dependence of the capacity factor on the pH of the mobile phase for four ionizable substances, namely, tenoxicam, piroxicam, meloxicam, and naproxen (I.S.). The effect of the mobile phase composition on the ionization constant was studied by measuring the pK(a) at different ACN concentrations, ranging from 30 to 40%. The adequate condition for the chromatographic determination of these compounds in pharmaceutical dosage forms was established based on the different retention behaviors of the species. An octadecylsilica Nucleosil C18 column (150 x 4.6 mm, 5 microm) was used for all the determinations. The chromatographic separation of oxicams was carried out using acetonitrile (ACN)/water at 35% v/v, containing 65 mM phosphoric acid and UV detection at a wavelength of 355 nm. The method developed was successfully applied to the simultaneous determination of these drug compounds in laboratory-prepared mixtures and their commercial pharmaceutical dosage forms. Each analysis requires no longer than 12 min.

  3. Fingerprint of Hedyotis diffusa Willd. by HPLC-MS.

    PubMed

    Yang, Ting; Yang, Yi-Hua; Yang, Ju-Yun; Chen, Ben-Mei; Duan, Ju-Ping; Yu, Shu-Yi; Ouyang, Hong-Tao; Cheng, Jun-Ping; Chen, Yu-Xiang

    2008-01-01

    A HPLC-MS fingerprint method has been developed based on the consistent chromatographic features of the major chemical constituents among 10 batches of Hedyotis diffusa Willd. Chromatographic separation was conducted on a Hypersil-Keystone Hypurity C(18) column using methanol:water:acetic acid as the mobile phase. Major compounds, including oleanolic acid, ursolic acid and ferulic acid, were analysed by HPLC-MS. Their analysis was ascertained by comparison with data derived from the standard compounds. The HPLC-MS fingerprint was successfully applied to analyse and differentiate samples from different geographical origins, or processing methods. H. diffusa was well distinguished from Hedyotis chrysotricha by HPLC-MS. Therefore the establishment of fingerprint of H. diffusa is critical in assessing and controlling its overall quality.

  4. Development and validation of a reversed-phase HPLC method for simultaneous estimation of ambroxol hydrochloride and azithromycin in tablet dosage form.

    PubMed

    Shaikh, K A; Patil, S D; Devkhile, A B

    2008-12-15

    A simple, precise and accurate reversed-phase liquid chromatographic method has been developed for the simultaneous estimation of ambroxol hydrochloride and azithromycin in tablet formulations. The chromatographic separation was achieved on a Xterra RP18 (250 mm x 4.6 mm, 5 microm) analytical column. A Mixture of acetonitrile-dipotassium phosphate (30 mM) (50:50, v/v) (pH 9.0) was used as the mobile phase, at a flow rate of 1.7 ml/min and detector wavelength at 215 nm. The retention time of ambroxol and azithromycin was found to be 5.0 and 11.5 min, respectively. The validation of the proposed method was carried out for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The linear dynamic ranges were from 30-180 to 250-1500 microg/ml for ambroxol hydrochloride and azithromycin, respectively. The percentage recovery obtained for ambroxol hydrochloride and azithromycin were 99.40 and 99.90%, respectively. Limit of detection and quantification for azithromycin were 0.8 and 2.3 microg/ml, for ambroxol hydrochloride 0.004 and 0.01 microg/ml, respectively. The developed method can be used for routine quality control analysis of titled drugs in combination in tablet formulation.

  5. Solid phase microextraction-high performance liquid chromatographic determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in the presence of sodium dodecyl sulfate surfactant.

    PubMed

    Malik, Ashok Kumar; Rai, Parmod Kumar

    2008-07-01

    A simple and sensitive method has been developed using preconcentration technique solid phase microextraction (SPME) and analytical technique HPLC-UV for the determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) from the environmental samples. Aqueous solution of anionic surfactant SDS was used for the extraction of both nitramine high explosives, viz., HMX and RDX from soil samples which were subsequently sorbed on SPME fiber. The static desorption was carried out in the desorption chamber of the SPME-HPLC interface in the presence of mobile phase ACN/methanol/water (30:35:35) and the subsequent chromatographic analysis at a flow rate of 0.5 mL/min and detection at 230 nm. For this purpose, a C(18), 5 microm RP analytical column was used as a separation medium in this method. Several parameters relating to SPME, e.g., adsorption/desorption time, concentration of salt, stirring rate, etc., were optimized. The method was linear over the range of 20-400 ng/mL for HMX and RDX standards in the presence of surfactant in aqueous phase, respectively. The correlation coefficient (R(2)) for HMX and RDX are 0.9998 and 0.9982, respectively. With SPME, the detection limits (S/N = 3) in ng/mL are 0.05 and 0.1 for HMX and RDX, respectively in the presence of the SDS surfactant. The developed method has been applied successfully to the analysis of real environmental samples like bore well water, river water, and ground alluvial soil.

  6. A validated high-performance liquid chromatographic method for the determination of moclobemide and its two metabolites in human plasma and application to pharmacokinetic studies.

    PubMed

    Plenis, Alina; Chmielewska, Aleksandra; Konieczna, Lucyna; Lamparczyk, Henryk

    2007-09-01

    A rapid and sensitive reversed-phase high-performance liquid chromatographic method (RP-HPLC) with ultraviolet detection has been developed for the determination of moclobemide and its metabolites, p-chloro-N-(-2-morpholinoethyl)benzamide N'-oxide (Ro 12-5637) and p-chloro-N-[2-(3-oxomorpholino)ethyl]-benzamide (Ro 12-8095), in human plasma. The assay was performed after single liquid-liquid extraction with dichloromethane at alkaline pH using phenacetin as the internal standard. Chromatographic separation was performed on a C(18) column using a mixture of acetonitrile and water (25:75, v/v), adjusted to pH 2.7 with ortho-phosphoric acid, as mobile phase. Spectrophotometric detection was performed at 239 nm. The method has been validated for accuracy, precision, selectivity, linearity, recovery and stability. The quantification limit for moclobemide and Ro 12-8095 was 10 ng/mL, and for Ro 12-5637 was 30 ng/mL. Linearity of the method was confirmed for the range 20-2500 ng/mL for moclobemide (r = 0.9998), 20-1750 ng/mL for Ro 12-8095 (r = 0.9996) and 30-350 ng/mL for Ro 12-5637 (r = 0.9991). Moreover, within-day and between-day precisions and accuracies of the method were established. The described method was successfully applied in pharmacokinetic studies of parent drug and its two metabolites after a single oral administration of 150 mg of moclobemide to 20 healthy volunteers. Copyright (c) 2007 John Wiley & Sons, Ltd.

  7. HPLC-ESI-MS/MS validated method for simultaneous quantification of zopiclone and its metabolites, N-desmethyl zopiclone and zopiclone-N-oxide in human plasma.

    PubMed

    Mistri, Hiren N; Jangid, Arvind G; Pudage, Ashutosh; Shrivastav, Pranav

    2008-03-15

    A simple, selective and sensitive isocratic HPLC method with triple quadrupole mass spectrometry detection has been developed and validated for simultaneous quantification of zopiclone and its metabolites in human plasma. The analytes were extracted using solid phase extraction, separated on Symmetry shield RP8 column (150 mm x 4.6 mm i.d., 3.5 microm particle size) and detected by tandem mass spectrometry with a turbo ion spray interface. Metaxalone was used as an internal standard. The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 0.5-150 ng/mL for both zopiclone and N-desmethyl zopiclone and 1-150 ng/mL for zopiclone-N-oxide. The intra-batch and inter-batch accuracy and precision evaluated at lower limit of quantification and quality control levels were within 89.5-109.1% and 3.0-14.7%, respectively, for all the analytes. The recoveries calculated for the analytes and internal standard were > or = 90% from spiked plasma samples. The validated method was successfully employed for a comparative bioavailability study after oral administration of 7.5 mg zopiclone (test and reference) to 16 healthy volunteers under fasted condition.

  8. Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry

    PubMed Central

    Shen, Xinggui; Chakraborty, Sourav; Dugas, Tammy R; Kevil, Christopher G

    2015-01-01

    Accurate measurement of hydrogen sulfide bioavailability remains a technical challenge due to numerous issues involving sample processing, detection methods used, and actual biochemical products measured. Our group and others have reported that reverse phase HPLC detection of sulfide dibimane (SDB) product from the reaction of H2S/HS− with monobromobimane allows for analytical detection of hydrogen sulfide bioavailability in free and other biochemical forms. However, it remains unclear whether possible interfering contaminants may contribute to HPLC SDB peak readings that may result in inaccurate measurements of bioavailable sulfide. In this study, we critically compared hydrogen sulfide dependent SDB detection using reverse phase HPLC (RP-HPLC) versus quantitative SRM electrospray ionization mass spectrometry (ESI/MS) to obtain greater clarity into the validity of the reverse phase HPLC method for analytical measurement of hydrogen sulfide. Using an LCQ-deca ion-trap mass spectrometer, SDB was identified by ESI/MS positive ion mode, and quantified by selected reaction monitoring (SRM) using hydrocortisone as an internal standard. Collision induced dissociation (CID) parameters were optimized at MS2 level for SDB and hydrocortisone. ESI/MS detection of SDB standard was found to be a log order more sensitive than RP-HPLC with a lower limit of 0.25 nM. Direct comparison of tissue and plasma SDB levels using RP-HPLC and ESI/MS methods revealed comparable sulfide levels in plasma, aorta, heart, lung and brain. Together, these data confirm the use of SDB as valid indicator of H2S bioavailability and highlights differences between analytical detection methods. PMID:24932544

  9. Simplified RP-HPLC method for multi-residue analysis of abamectin, emamectin benzoate and ivermectin in rice.

    PubMed

    Xie, Xianchuan; Gong, Shu; Wang, Xiaorong; Wu, Yinxing; Zhao, Li

    2011-01-01

    A rapid, reliable and sensitive reverse-phase high-performance liquid chromatography method with fluorescence detection (RP-FLD-HPLC) was developed and validated for simultaneous analysis of the abamectin (ABA), emamectin (EMA) benzoate and ivermectin (IVM) residues in rice. After extraction with acetonitrile/water (2 : 1) with sonication, the avermectin (AVMs) residues were directly derivatised by N-methylimidazole (N-NMIM) and trifluoroacetic anhydride (TFAA) and then analysed on RP-FLD-HPLC. A good linear relationship (r(2 )> 0.99) was obtained for three AVMs ranging from 0.01 to 5 microg ml(-1), i.e. 0.01-5.0 microg g(-1) in rice matrix. The limit of detection (LOD) and the limit of quantification (LOQ) were between 0.001 and 0.002 microg g(-1) and between 0.004 and 0.006 microg g(-1), respectively. Recoveries were from 81.9% to 105.4% and precision less than 12.4%. The proposed method was successfully applied to routine analysis of the AVMs residues in rice.

  10. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms.

    PubMed

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm × 4mm × 5 μm) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS was 2.733 min and its formulation was exposed to acidic, alkaline, photolytic, thermal and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 0.5-200μg/ml. The percentage recovery was 99.46. F-test and t-test at 95% confidence level were used to check the intermediate precision data obtained under different experimental setups; the calculated value was found to be less than the critical value.

  11. A comparative evaluation of different ionic liquids for arsenic species separation and determination in wine varietals by liquid chromatography - hydride generation atomic fluorescence spectrometry.

    PubMed

    Castro Grijalba, Alexander; Fiorentini, Emiliano F; Martinez, Luis D; Wuilloud, Rodolfo G

    2016-09-02

    The application of different ionic liquids (ILs) as modifiers for chromatographic separation and determination of arsenite [As(III)], arsenate [As(V)], dimethylarsonic acid (DMA) and monomethylarsonic acid (MMA) species in wine samples, by reversed-phase high performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry detection (RP-HPLC-HG-AFS) was studied in this work. Several factors influencing the chromatographic separation of the As species, such as pH of the mobile phase, buffer solution concentration, buffer type, IL concentration and length of alkyl groups in ILs were evaluated. The complete separation of As species was achieved using a C18 column in isocratic mode with a mobile phase composed of 0.5% (v/v) 1-octyl-3-methylimidazolium chloride ([C8mim]Cl) and 5% (v/v) methanol at pH 8.5. A multivariate methodology was used to optimize the variables involved in AFS detection of As species after they were separated by HPLC. The ILs showed remarkable performance for the separation of As species, which was obtained within 18min with a resolution higher than 0.83. The limits of detection for As(III), As(V), MMA and DMA were 0.81, 0.89, 0.62 and 1.00μg As L(-1). The proposed method was applied for As speciation analysis in white and red wine samples originated from different grape varieties. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

    PubMed

    Hewala, Ismail; El-Fatatry, Hamed; Emam, Ehab; Mabrouk, Mokhtar

    2011-01-01

    A simple, rapid, and sensitive RP-HPLC method using photodiode array detection was developed and validated for the simultaneous determination of granisetron hydrochloride, 1-methyl-1H-indazole-3-carboxylic acid (the main degradation product of granisetron), sodium benzoate, methylparaben, propylparaben, and 4-hydroxybenzoic acid (the main degradation product of parabens) in granisetron oral drops and solutions. The separation of the compounds was achieved within 8 min on a SymmetryShield RP18 column (100 x 4.6 mm id, 3.5 microm particle size) using the mobile phase acetonitrile--0.05 M KH2PO4 buffered to pH 3 using H3PO4 (3+7, v/v). The photodiode array detector was used to test the purity of the peaks, and the chromatograms were extracted at 240 nm. The method was validated, and validation acceptance criteria were met in all cases. The robust method was successfully applied to the determination of granisetron and preservatives, as well as their degradation products in different batches of granisetron oral drops and solutions. The method proved to be sensitive for determination down to 0.04% (w/w) of granisetron degradation product relative to granisetron and 0.03% (w/w) 4-hydroxybenzoic acid relative to total parabens.

  13. Development of an HPLC method for determination of metabolic compounds in myocardial tissue.

    PubMed

    Volonté, M G; Yuln, G; Quiroga, P; Consolini, A E

    2004-05-28

    The determination of adenine nucleotides and creatine compounds has great importance in the characterization of ischemic myocardial injury and post-ischemic recovery. It was developed by an HPLC method for the quantification of creatine (Cr), creatine phosphate (CrP), hypoxanthine (HX), AMP, adenosine (Ad), ADP and ATP in isolated perfused rat hearts. The chromatographic conditions were: RP 18 column; mobile phase composed by KH(2)PO(4) (215 mM), tetrabutylammonium hydrogen sulfate (2.3mM), acetonitrile (4%) and KOH (1M 0.4%); flow rate 1 ml min(-1); temperature 25 degrees C; injection volume 20 microl; detection at 220 nm and height peak (HP) as the integration parameter. The method was validated by means of linearity and sensitivity evaluations, using calibration curves done with five concentration levels of each compound. The limits of quantification (LOQ) were also determined. The system precision was calculated as the coefficient of variation for five injections for each compound tested. The purity of the peaks was established using enzymatic peak shift analysis with hexokinase and creatine kinase and also comparing HP at various wavelengths. Frozen hearts were homogenized with a mechanical homogenizer for 3 min at 0 degrees C added with 5 ml of 0.4N HCLO(4). After precipitation with 0.8 ml of 2M KOH the extract was shaked for 2 min and later centrifuged at 0 degrees C for 10 min. The supernatant was kept on ice, filtrated and injected into the HPLC system. The results show that the method for the determination of Cr, CrP, HX, AMP, Ad, ADP and ATP by HPLC here described has good linearity, LOQ, precision, specificity and is simple and rapid to perform.

  14. A Simple, Fast, Low Cost, HPLC/UV Validated Method for Determination of Flutamide: Application to Protein Binding Studies

    PubMed Central

    Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin

    2016-01-01

    Purpose: The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Methods: Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Results: Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r2 > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Conclusion: Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide. PMID:27478788

  15. [Assay of three hydrolyzable tannins in Fructus Chebulae from different habitats by RP-HPLC].

    PubMed

    Ding, G; Liu, Y; Wang, W

    2000-06-01

    Three hydrolyzable tannins chebulinic acid (I), chebulagic acid(II) and 1,3, 6-tri-O-galloyl-beta-D-glucose (III) in Fructus Chebulae from different habitats were determined by RP-HPLC method. The contents of I and II were obviously interrelated with the variety and characteristics of Fructus Chebulae. It's suitable to use I and II as indexes in quality evaluation of the crude drug of Fructus Chebulae.

  16. Development and validation of reverse phase high performance liquid chromatography for citral analysis from essential oils.

    PubMed

    Gaonkar, Roopa; Yallappa, S; Dhananjaya, B L; Hegde, Gurumurthy

    2016-11-15

    Citral is a widely used monoterpene aldehyde in aromatherapy, food and pesticide industries. A new validated reverse phase high performance liquid chromatography (RP - HPLC) procedure for the detection and quantification of cis-trans isomers of citral was developed. The RP-HPLC analysis was carried out using Enable C - 18G column (250×4.6mm, 5μ), with acetonitrile and water (70: 30) mobile phase in isocratic mode at 1mL/min flow. A photodiode array (PDA) detector was set at 233nm for the detection of citral. The method showed linearity, selectivity and accuracy for citral in the range of 3-100μg/mL. In order to compare the new RP-HPLC method with the available methods, one of the commercially available essential oil from Cymbopogon flexuosus was analyzed using new RP-HPLC method and the same was analyzed using GC-MS for the comparison of the method for the detection of citral. The GC-MS analysis was done using mass selective detector (MSD) showed citral content to be of 72.76%; wherein the new method showed to contain that same at 74.98%. To prove the application of the new method, essential oils were extracted from lemongrass, lemon leaves and mosambi peels by steam distillation. The citral content present in the essential and also in the condensate was analyzed. The method was found to be suitable for the analysis of citral in essential oils and water based citral formulations with a very good resolution of its components geranial and neral. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A rapid HPLC column switching method for sample preparation and determination of β-carotene in food supplements.

    PubMed

    Brabcová, Ivana; Hlaváčková, Markéta; Satínský, Dalibor; Solich, Petr

    2013-11-15

    A simple and automated HPLC column-switching method with rapid sample pretreatment has been developed for quantitative determination of β-carotene in food supplements. Commercially samples of food supplements were dissolved in chloroform with help of saponification with 1M solution of sodium hydroxide in ultrasound bath. A 20-min sample dissolution/extraction step was necessary before chromatography analysis to transfer β-carotene from solid state of food supplements preparations (capsules,tablets) to chloroform solution. Sample volume - 3μL of chloroform phase was directly injected into the HPLC system. Next on-line sample clean-up was achieved on the pretreatment precolumn Chromolith Guard Cartridge RP-18e (Merck), 10×4.6mm, with a washing mobile phase (methanol:water, 92:8, (v/v)) at a flow rate of 1.5mL/min. Valve switch to analytical column was set at 2.5min in a back-flush mode. After column switching to the analytical column Ascentis Express C-18, 30×4.6mm, particle size 2.7μm (Sigma Aldrich), the separation and determination of β-carotene in food supplements was performed using a mobile phase consisting of 100% methanol, column temperature at 60°C and flow rate 1.5mL/min. The detector was set at 450nm. Under the optimum chromatographic conditions standard calibration curve was measured with good linearity - correlation coefficient for β-carotene (r(2)=0.999014; n=6) between the peak areas and concentration of β-carotene 20-200μg/mL. Accuracy of the method defined as a mean recovery was in the range 96.66-102.40%. The intraday method precision was satisfactory at three concentration levels 20, 125 and 200μg/mL and relative standard deviations were in the range 0.90-1.02%. The chromatography method has shown high sample throughput during column-switching pretreatment process and analysis in one step in short time (6min) of the whole chromatographic analysis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Development and Validation of an RP-HPLC Method for the Determination of Vinpocetine and Folic Acid in the Presence of a Vinpocetine Alkaline Degradation Product in Bulk and in Capsule Form.

    PubMed

    Elkady, Ehab F; Tammam, Marwa H; Mohamed, Ayman A

    2017-05-01

    An alkaline-forced degradation hydrolytic product of vinpocetine was prepared and characterized by 1H-NMR, FTIR spectroscopy, and MS. Subsequently, a simple, selective, and validated reversed-phase HPLC method was developed for the simultaneous estimation of vinpocetine and folic acid in the presence of a vinpocetine alkaline degradation product. Chromatographic separation was achieved using an isocratic mobile phase consisting of acetonitrile-0.02 M KH2PO4 [containing 0.2% (v/v) triethylamine and adjusted to pH 6 with orthophosphoric acid; (80 + 20, v/v)] at a flow rate of 0.9 mL/min at ambient temperature on a Eurospher II C18 (250 × 4.6 mm, 5 μm) column, with UV detection at 280 nm for folic acid and 230 nm for vinpocetine and its alkaline hydrolytic product. Linearity, accuracy, and precision were found to be acceptable over a concentration range of 12.5-200 μg/mL for vinpocetine and 1-16 μg/mL for folic acid. The proposed method was successfully applied for the determination of both drugs and a vinpocetine hydrolysis product in a laboratory-prepared mixture and in a capsule containing both drugs.

  19. Tocochromanols composition in kernels recovered from different apricot varieties: RP-HPLC/FLD and RP-UPLC-ESI/MS(n) study.

    PubMed

    Górnaś, Paweł; Mišina, Inga; Grāvīte, Ilze; Soliven, Arianne; Kaufmane, Edīte; Segliņa, Dalija

    2015-01-01

    Composition of tocochromanols in kernels recovered from 16 different apricot varieties (Prunus armeniaca L.) was studied. Three tocopherol (T) homologues, namely α, γ and δ, were quantified in all tested samples by an RP-HPLC/FLD method. The γ-T was the main tocopherol homologue identified in apricot kernels and constituted approximately 93% of total detected tocopherols. The RP-UPLC-ESI/MS(n) method detected trace amounts of two tocotrienol homologues α and γ in the apricot kernels. The concentration of individual tocopherol homologues in kernels of different apricots varieties, expressed in mg/100 g dwb, was in the following range: 1.38-4.41 (α-T), 42.48-73.27 (γ-T) and 0.77-2.09 (δ-T). Moreover, the ratio between individual tocopherol homologues α:γ:δ was nearly constant in all varieties and amounted to approximately 2:39:1.

  20. A Simple, Fast, Low Cost, HPLC/UV Validated Method for Determination of Flutamide: Application to Protein Binding Studies.

    PubMed

    Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin

    2016-06-01

    The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r(2) > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide.

  1. Determination of rifampicin in human plasma by high-performance liquid chromatography coupled with ultraviolet detection after automatized solid-liquid extraction.

    PubMed

    Louveau, B; Fernandez, C; Zahr, N; Sauvageon-Martre, H; Maslanka, P; Faure, P; Mourah, S; Goldwirt, L

    2016-12-01

    A precise and accurate high-performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid-phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP 8 column using a mixture of 0.05 m acetate buffer pH 5.7-acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Development of chromatographic methods for the determination of genotoxic impurities in cloperastine fendizoate.

    PubMed

    García, Antonia; Rupérez, Francisco J; Ceppa, Florencia; Pellati, Federica; Barbas, Coral

    2012-03-05

    The classification of an impurity of a drug substance as genotoxic means that the "threshold of toxicological concern" (TTC) value of 1.5 μg/day intake, considered to be associated with an acceptable risk, should be the admissible limit in the raw material and that leads to new analytical challenges. In this study, reliable chromatographic methods were developed and applied as limit tests for the control of three genotoxic impurities (GTIs) in cloperastine fendizoate, drug widely used as an antitussive active pharmaceutical ingredient (API). In particular, GC-MS was applied to the determination of one alkyl halide (2-chloroethanol, 2-CE), while HPLC-DAD was selected for the analysis of two sulfonate esters (methyl p-toluenesulfonate, MPTS, and 2-chloroethyl p-toluenesulfonate, CEPTS). Regarding GC-MS, strong anion-exchange (SAX)-SPE was applied to remove fendizoate from the sample solutions, due its low volatility and its high amount in the raw material. The GC-MS analysis was performed on a Factor Four VF-23 ms capillary column (30 m × 0.25 mm I.D., film thickness 0.25 μm, Varian). Single ion-monitoring (SIM) detection mode was set at m/z 80. In the case of HPLC-DAD, a suitable optimization of the chromatographic conditions was carried out in order to obtain a good separation of the impurity peaks from the drug substance peaks. The optimized method utilizes a SymmetryShield RP(8) column (250 mm × 4.6 mm, 5 μm, Waters) kept at 50°C, with phosphate buffer (pH 3.0; 10 mM)-methanol (containing 10% ACN) (45:55, v/v) as the mobile phase, at the flow-rate of 1.7 mL/min and UV detection at 227 nm. The required sensitivity level was achieved by injecting 80 μL of sample solution, purified from fendizoate by SAX-SPE, followed by a 1:1 (v/v) dilution of the SPE eluate with water. For both GC-MS and HPLC-DAD, the method validation was performed in relation to specificity and limit of detection (LOD), as required by ICH guidelines in relation to limit assays. The developed methods were successfully applied for the determination of GTIs in five different batches of cloperastine fendizoate. In all the analyzed batches, the three target GTIs were below the concentration limit. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations.

    PubMed

    Adi-Dako, Ofosua; Oppong Bekoe, Samuel; Ofori-Kwakye, Kwabena; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5  μ m, 4.6 × 150 mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol : water : acetic acid (60 : 30 : 10, v/v/v) at a flow rate of 1.0 ml/min. The detection of the drug was successfully achieved at a wavelength of 254 nm. The retention time obtained for the drug was 2.26 min. The proposed method produced linear detectable responses in the concentration range of 0.02 to 0.4 mg/ml of hydrocortisone. High recoveries of 98-101% were attained at concentration levels of 80%, 100%, and 120%. The intraday and interday precision (RSD) were 0.19-0.55% and 0.33-0.71%, respectively. A comparison of hydrocortisone analyses data from the developed method and the official USP method showed no significant difference ( p > 0.05) at a 95% confidence interval. The method was successfully applied to the determination and quantification of hydrocortisone in six controlled-release and fifteen conventional release pharmaceutical preparations.

  4. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    PubMed Central

    Oppong Bekoe, Samuel; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5 μm, 4.6 × 150 mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol : water : acetic acid (60 : 30 : 10, v/v/v) at a flow rate of 1.0 ml/min. The detection of the drug was successfully achieved at a wavelength of 254 nm. The retention time obtained for the drug was 2.26 min. The proposed method produced linear detectable responses in the concentration range of 0.02 to 0.4 mg/ml of hydrocortisone. High recoveries of 98–101% were attained at concentration levels of 80%, 100%, and 120%. The intraday and interday precision (RSD) were 0.19–0.55% and 0.33–0.71%, respectively. A comparison of hydrocortisone analyses data from the developed method and the official USP method showed no significant difference (p > 0.05) at a 95% confidence interval. The method was successfully applied to the determination and quantification of hydrocortisone in six controlled-release and fifteen conventional release pharmaceutical preparations. PMID:28660092

  5. Development and validation of reversed-phase HPLC gradient method for the estimation of efavirenz in plasma.

    PubMed

    Gupta, Shweta; Kesarla, Rajesh; Chotai, Narendra; Omri, Abdelwahab

    2017-01-01

    Efavirenz is an anti-viral agent of non-nucleoside reverse transcriptase inhibitor category used as a part of highly active retroviral therapy for the treatment of infections of human immune deficiency virus type-1. A simple, sensitive and rapid reversed-phase high performance liquid chromatographic gradient method was developed and validated for the determination of efavirenz in plasma. The method was developed with high performance liquid chromatography using Waters X-Terra Shield, RP18 50 x 4.6 mm, 3.5 μm column and a mobile phase consisting of phosphate buffer pH 3.5 and Acetonitrile. The elute was monitored with the UV-Visible detector at 260 nm with a flow rate of 1.5 mL/min. Tenofovir disoproxil fumarate was used as internal standard. The method was validated for linearity, precision, accuracy, specificity, robustness and data obtained were statistically analyzed. Calibration curve was found to be linear over the concentration range of 1-300 μg/mL. The retention times of efavirenz and tenofovir disoproxil fumarate (internal standard) were 5.941 min and 4.356 min respectively. The regression coefficient value was found to be 0.999. The limit of detection and the limit of quantification obtained were 0.03 and 0.1 μg/mL respectively. The developed HPLC method can be useful for quantitative pharmacokinetic parameters determination of efavirenz in plasma.

  6. Preparation and characterization of a new microwave immobilized poly(2-phenylpropyl)methylsiloxane stationary phase for reversed phase high-performance liquid chromatography.

    PubMed

    Begnini, Fernanda R; Jardim, Isabel C S F

    2013-07-05

    A new reversed phase high-performance liquid chromatography (RP-HPLC) stationary phase was prepared and its chromatographic and physical-chemical properties were evaluated. The new stationary phase was prepared with a silica support and poly(2-phenylpropyl)methylsiloxane (PPPMS), a phenyl type polysiloxane copolymer. Since this is a new copolymer and there is little information in the literature, it was submitted to physical-chemical characterization by infrared spectroscopy and thermogravimetry. The chromatographic phase was prepared through sorption and microwave immobilization of the copolymer onto a silica support. The chromatographic performance was evaluated by employing test procedures suggested by Engelhardt and Jungheim, Tanaka and co-workers, Neue, and Szabó and Csató. These test mixtures provide information about the hydrophobic selectivity, silanophilic activity, ion-exchange capacity, shape selectivity and interaction with polar analytes of the new Si-PPPMS reversed phase. Stability tests were developed using accelerated aging tests under both basic and acidic conditions to provide information about the lifetime of the packed columns. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. An high-performance liquid chromatographic method for the simultaneous analysis of acetylcarnitine taurinate, carnosine, asparagine and potassium aspartate and for the analysis of phosphoserine in alimentary supplements.

    PubMed

    Gatti, R; Andreatta, P; Boschetti, S

    2013-07-12

    A RP-HPLC method with pre-column derivatization was developed and validated for the simultaneous quantification of carnosine (Carn), acetylcarnitine taurinate (AC-Tau), asparagine (Asn), potassium aspartate (Asp) and for the determination of phosphoserine (p-Ser) in new and commercial alimentary supplements. The effect of complex matrices was evaluated by the study of the amino acid derivatization reaction with 2,4-dinitrofluorobenzene (DNFB) both in standard and placebo solutions. The reaction was carried out for 20 min at 70 °C in alkaline medium (pH10) for p-Ser analysis, whereas for 60 min in the case of Carn, AC-Tau, Asn and Asp analysis. The adducts have been separated on a Discovery RP Amide C16 (250 mm×4.6mm, i.d.) column using a mobile phase consisting of acetonitrile (ACN) and triethylammonium (TEA) phosphate buffer (pH 3, 0.05 M) under gradient elution conditions at a flow-rate of 0.8 mL/min. Detection was set at λ=360 nm. The validation parameters such as linearity, sensitivity, accuracy, precision and specificity were found to be highly satisfactory. Linear responses were observed by placebo solutions (determination coefficient ≤0.9996). Intra-day precision (relative standard deviation, RSD) was ≤1.06% for corrected peak area and ≤0.99% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all examined compounds (from 97.7% to 101.5%) with RSD ranging from 0.5% to 1.3%). The high stability of derivatized compound solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of a large number of samples and consecutive chromatographic analyses by the use of an autosampler. The developed method can be considered suitable for the quality control of new and commercial products. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method

    PubMed Central

    Ghari, Tayebeh; Kobarfard, Farzad; Mortazavi, Seyed Alireza

    2013-01-01

    The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms. PMID:24250672

  9. Solid-phase extraction NMR studies of chromatographic fractions of saponins from Quillaja saponaria.

    PubMed

    Nyberg, Nils T; Baumann, Herbert; Kenne, Lennart

    2003-01-15

    The saponin mixture QH-B from the tree Quillaja saponaria var. Molina was fractionated by RP-HPLC in several steps. The fractions were analyzed by solid-phase extraction NMR (SPE-NMR), a technique combining the workup by solid-phase extraction with on-line coupling to an NMR flow probe. Together with MALDI-TOF mass spectrometry and comparison with chemical shifts of similar saponins, the structures of both major and minor components in QH-B could be obtained. The procedure described is a simple method to determine the structure of components in a complex mixture. The two major fractions of the mixture were found to contain at least 28 saponins, differing in the carbohydrate substructures. Eight of these have not previously been determined. The 28 saponins formed 14 equilibrium pairs by the migration of an O-acyl group between two adjacent positions on a fucosyl residue.

  10. Physico-chemical behaviour of β irradiated plastic materials currently used as packagings and medical products

    NASA Astrophysics Data System (ADS)

    Yagoubi, N.; Baillet, A.; Pellerin, F.; Ferrier, D.

    1995-11-01

    The combined chromatographic technics and thermal analysis constitute an informative methodology for studying the modifications which could occur following a radiotreatment of plastic material at different doses (25 to 100 kGy). Several plastic materials used as packagings (PVC, PE, PS) were investigated. SEC method coupled with UV and DDL detections was applied to document any changes in molecular weight distribution. Reticulation and scission were the main observed degradation phenomena. These structural modifications were supported by TGA data, while the DSC provided information on modifications in crystallinity. In addition, RP-HPLC was carried out for the evaluation of the radiochemical behaviour of the additives and monomers. Firstly we demonstrated the degradation of high molecular weight phenolic antioxidants in BHT within the PEVA. Secondly, the modifications of amino 6 caproic acid and ɛ caprolactam, present in polyamid 6, depend on the irradiation doses.

  11. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    PubMed

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  12. Development and validation of a high-performance liquid chromatography method for the quantification of talazoparib in rat plasma: Application to plasma protein binding studies.

    PubMed

    Hidau, Mahendra Kumar; Kolluru, Srikanth; Palakurthi, Srinath

    2018-02-01

    A sensitive and selective RP-HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD-20A UV-vis) at a λ max of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol-acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100-2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method. Copyright © 2017 John Wiley & Sons, Ltd.

  13. A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection.

    PubMed

    Chemmalil, Letha; Suravajjala, Sreekanth; See, Kate; Jordan, Eric; Furtado, Marsha; Sun, Chong; Hosselet, Stephen

    2015-01-01

    This paper describes a novel approach for the quantitation of nonderivatized sialic acid in glycoproteins, separated by hydrophilic interaction chromatography, and detection by Nano Quantity Analyte Detector (NQAD). The detection technique of NQAD is based on measuring change in the size of dry aerosol and converting the particle count rate into chromatographic output signal. NQAD detector is suitable for the detection of sialic acid, which lacks sufficiently active chromophore or fluorophore. The water condensation particle counting technology allows the analyte to be enlarged using water vapor to provide highest sensitivity. Derivatization-free analysis of glycoproteins using HPLC/NQAD method with PolyGLYCOPLEX™ amide column is well correlated with HPLC method with precolumn derivatization using 1, 2-diamino-4, 5-methylenedioxybenzene (DMB) as well as the Dionex-based high-pH anion-exchange chromatography (or ion chromatography) with pulsed amperometric detection (HPAEC-PAD). With the elimination of derivatization step, HPLC/NQAD method is more efficient than HPLC/DMB method. HPLC/NQAD method is more reproducible than HPAEC-PAD method as HPAEC-PAD method suffers high variability because of electrode fouling during analysis. Overall, HPLC/NQAD method offers broad linear dynamic range as well as excellent precision, accuracy, repeatability, reliability, and ease of use, with acceptable comparability to the commonly used HPAEC-PAD and HPLC/DMB methods. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  14. A RP-HPLC method for quantification of diclofenac sodium released from biological macromolecules.

    PubMed

    Bhattacharya, Shiv Sankar; Banerjee, Subham; Ghosh, Ashoke Kumar; Chattopadhyay, Pronobesh; Verma, Anurag; Ghosh, Amitava

    2013-07-01

    Interpenetrating network (IPN) microbeads of sodium carboxymethyl locust bean gum (SCMLBG) and sodium carboxymethyl cellulose (SCMC) containing diclofenac sodium (DS), a nonsteroidal anti-inflammatory drug, were prepared by single water-in-water (w/w) emulsion gelation process using AlCl3 as cross-linking agent in a complete aqueous environment. Pharmacokinetic study of these IPN microbeads was then carried out by a simple and feasible high-performance liquid chromatographic method with UV detection which was developed and validated for the quantification of diclofenac sodium in rabbit plasma. The chromatographic separation was carried out in a Hypersil BDS, C18 column (250 mm × 4.6 mm; 5 m). The mobile phase was a mixture of acetonitrile and methanol (70:30, v/v) at a flow rate of 1.0 ml/min. The UV detection was set at 276 nm. The extraction recovery of diclofenac sodium in plasma of three quality control (QC) samples was ranged from 81.52% to 95.29%. The calibration curve was linear in the concentration range of 20-1000 ng/ml with the correlation coefficient (r(2)) above 0.9951. The method was specific and sensitive with the limit of quantification of 20 ng/ml. In stability tests, diclofenac sodium in rabbit plasma was stable during storage and assay procedure. Copyright © 2013. Published by Elsevier B.V.

  15. Quantification of residual nitrite and nitrate in ham by reverse-phase high performance liquid chromatography/diode array detector.

    PubMed

    Ferreira, I M P L V O; Silva, S

    2008-02-15

    Nitrite and nitrate are used as additives in ham industry to provide colour, taste and protect against clostridia. The classical colorimetric methods widely used to determine nitrite and nitrate are laborious, suffer from matrix interferences and involve the use of toxic cadmium. The use of chromatography is potentially attractive since it is more rapid, sensitive, selective and provides reliable and accurate results. A rapid and cost-effective RP-HPLC method with diode array detector was optimized and validated for quantification of nitrites and nitrates in ham. The chromatographic separation was achieved using a HyPurity C18, 5 microm chromatographic column and gradient elution with 0.01 M n-octylamine and 5mM tetrabutylammonium hydrogenosulphate to pH 6.5. The determinations were performed in the linear range of 0.0125-10.0mg/L for nitrite and 0.0300-12.5 g/L for nitrate. The detection limits were 0.019 and 0.050 mg/kg, respectively. The reliability of the method in terms of precision and accuracy was evaluated. Coefficients of variation lower than 2.89% and 5.47% were obtained for nitrite and nitrate, respectively (n=6). Recoveries of residual nitrite/nitrate ranged between 93.6% and 104.3%. Analysis of cooked and dried ham samples was performed, and the results obtained were in agreement with reference procedures.

  16. Simultaneous determination of potassium guaiacolsulfonate, guaifenesin, diphenhydramine HCl and carbetapentane citrate in syrups by using HPLC-DAD coupled with partial least squares multivariate calibration.

    PubMed

    Dönmez, Ozlem Aksu; Aşçi, Bürge; Bozdoğan, Abdürrezzak; Sungur, Sidika

    2011-02-15

    A simple and rapid analytical procedure was proposed for the determination of chromatographic peaks by means of partial least squares multivariate calibration (PLS) of high-performance liquid chromatography with diode array detection (HPLC-DAD). The method is exemplified with analysis of quaternary mixtures of potassium guaiacolsulfonate (PG), guaifenesin (GU), diphenhydramine HCI (DP) and carbetapentane citrate (CP) in syrup preparations. In this method, the area does not need to be directly measured and predictions are more accurate. Though the chromatographic and spectral peaks of the analytes were heavily overlapped and interferents coeluted with the compounds studied, good recoveries of analytes could be obtained with HPLC-DAD coupled with PLS calibration. This method was tested by analyzing the synthetic mixture of PG, GU, DP and CP. As a comparison method, a classsical HPLC method was used. The proposed methods were applied to syrups samples containing four drugs and the obtained results were statistically compared with each other. Finally, the main advantage of HPLC-PLS method over the classical HPLC method tried to emphasized as the using of simple mobile phase, shorter analysis time and no use of internal standard and gradient elution. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Rapid-gradient HPLC method for measuring drug interactions with immobilized artificial membrane: comparison with other lipophilicity measures.

    PubMed

    Valko, K; Du, C M; Bevan, C D; Reynolds, D P; Abraham, M H

    2000-08-01

    A fast-gradient high-performance liquid chromatographic (HPLC) method has been suggested to characterize the interactions of drugs with an immobilized artificial membrane (IAM). With a set of standards, the gradient retention times can be converted to Chromatographic Hydrophobicity Index values referring to IAM chromatography (CHI(IAM)) that approximates an acetonitrile concentration with which the equal distribution of compound can be achieved between the mobile phase and IAM. The CHI(IAM) values are more suitable for interlaboratory comparison and for high throughput screening of new molecular entities than the log k(IAM) values (isocratic retention factor on IAM). The fast-gradient method has been validated against the isocratic log k(IAM) values using the linear free energy relationship solvation equations based on the data from 48 compounds. The compound set was selected to provide a wide range and the least cross-correlation between the molecular descriptors in the solvation equation: (2) where SP is a solute property (e.g., logarithm of partition coefficients, reversed-phase (RP)-HPLC retention parameters, such as log k, log k(w), etc.) and the explanatory variables are solute descriptors as follows: R(2) is an excess molar refraction that can be obtained from the measured refractive index of a compound, pi(2)(H) is the solute dipolarity/polarizability, summation operatoralpha(2)(H) and summation operatorbeta(2)(0) are the solute overall or effective hydrogen-bond acidity and basicity, respectively, and V(x) is the McGowan characteristic volume (in cm(3)/100 mol) that can be calculated for any solute simply from molecular structure using a table of atomic constants. It was found that the relative constants of the solvation equation were very similar for the CHI(IAM) and for the log k(IAM). The IAM lipophilicity scale was quite similar to the octanol/water lipophilicity scale for neutral compounds. The effect of charge on the interaction with IAM was studied by varying the mobile phase pH. Copyright 2000 Wiley-Liss, Inc.

  18. Astragalin from Cassia alata Induces DNA Adducts in Vitro and Repairable DNA Damage in the Yeast Saccharomyces cerevisiae

    PubMed Central

    Saito, Samuel; Silva, Givaldo; Santos, Regineide Xavier; Gosmann, Grace; Pungartnik, Cristina; Brendel, Martin

    2012-01-01

    Reverse phase-solid phase extraction from Cassia alata leaves (CaRP) was used to obtain a refined extract. Higher than wild-type sensitivity to CaRP was exhibited by 16 haploid Saccharomyces cerevisiae mutants with defects in DNA repair and membrane transport. CaRP had a strong DPPH free radical scavenging activity with an IC50 value of 2.27 μg mL−1 and showed no pro-oxidant activity in yeast. CaRP compounds were separated by HPLC and the three major components were shown to bind to DNA in vitro. The major HPLC peak was identified as kampferol-3-O-β-d-glucoside (astragalin), which showed high affinity to DNA as seen by HPLC-UV measurement after using centrifugal ultrafiltration of astragalin-DNA mixtures. Astragalin-DNA interaction was further studied by spectroscopic methods and its interaction with DNA was evaluated using solid-state FTIR. These and computational (in silico) docking studies revealed that astragalin-DNA binding occurs through interaction with G-C base pairs, possibly by intercalation stabilized by H-bond formation. PMID:22489129

  19. Astragalin from Cassia alata induces DNA adducts in vitro and repairable DNA damage in the yeast Saccharomyces cerevisiae.

    PubMed

    Saito, Samuel; Silva, Givaldo; Santos, Regineide Xavier; Gosmann, Grace; Pungartnik, Cristina; Brendel, Martin

    2012-01-01

    Reverse phase-solid phase extraction from Cassia alata leaves (CaRP) was used to obtain a refined extract. Higher than wild-type sensitivity to CaRP was exhibited by 16 haploid Saccharomyces cerevisiae mutants with defects in DNA repair and membrane transport. CaRP had a strong DPPH free radical scavenging activity with an IC(50) value of 2.27 μg mL(-1) and showed no pro-oxidant activity in yeast. CaRP compounds were separated by HPLC and the three major components were shown to bind to DNA in vitro. The major HPLC peak was identified as kampferol-3-O-β-d-glucoside (astragalin), which showed high affinity to DNA as seen by HPLC-UV measurement after using centrifugal ultrafiltration of astragalin-DNA mixtures. Astragalin-DNA interaction was further studied by spectroscopic methods and its interaction with DNA was evaluated using solid-state FTIR. These and computational (in silico) docking studies revealed that astragalin-DNA binding occurs through interaction with G-C base pairs, possibly by intercalation stabilized by H-bond formation.

  20. Measurement of lumefantrine and its metabolite in plasma by high performance liquid chromatography with ultraviolet detection.

    PubMed

    Khalil, Insaf F; Abildrup, Ulla; Alifrangis, Lene H; Maiga, Deogratius; Alifrangis, Michael; Hoegberg, Lotte; Vestergaard, Lasse S; Persson, Ola Per-Eric; Nyagonde, Nyagonde; Lemnge, Martha M; Theander, Thor G; Bygbjerg, Ib C

    2011-01-05

    Artemether-lumefantrine (ARM-LUM) has in recent years become the first-line treatment for uncomplicated malaria in many Sub-Saharan African countries. Vigorous monitoring of the therapeutic efficacy of this treatment is needed. This requires high-quality studies following standard protocols; ideally, such studies should incorporate measurement of drug levels in the study patients to exclude the possibility that insufficient drug levels explain an observed treatment failure. Several methods for measuring lumefantrine (LUM) in plasma by HPLC are available; however, several of these methods have some limitations in terms of high costs and limited feasibility arising from large required sample volumes and demanding sample preparation. Therefore, we set out to develop a simpler reversed phase high performance liquid chromatography (RP-HPLC) method based on UV detection for simultaneous measurement of LUM and its major metabolite the desbutyl LUM (DL) in plasma. Halofantrine was used as an internal standard. Liquid-liquid extraction of samples was carried out using hexane-ethyl acetate (70:30, v/v). Chromatographic separation was carried out on a Synergi Polar-RP column (250 mm × 300 mm, particle size 4 μm). The mobile phase consisted of acetonitrile-0.1M ammonium acetate buffer adjusted to pH 4.9 (85:15%, v/v). Absorbance of the compounds was monitored at 335 nm using a reference wavelength of 360 nm. Absolute extraction recovery for LUM and DL were 88% and 90%, respectively. Inter- and intraday coefficients of variation for LUM and DL were ≤ 10%. The lower limits of quantification for LUM and DL were 12.5 and 6.5 ng/ml, respectively. After validation, the methodology was transferred to a local laboratory in Tanga Tanzania and samples from a small subset of malaria patients were analysed for LUM. The method appears to be applicable in settings with limited facilities. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Central composite design with the help of multivariate curve resolution in loadability optimization of RP-HPLC to scale-up a binary mixture.

    PubMed

    Taheri, Mohammadreza; Moazeni-Pourasil, Roudabeh Sadat; Sheikh-Olia-Lavasani, Majid; Karami, Ahmad; Ghassempour, Alireza

    2016-03-01

    Chromatographic method development for preparative targets is a time-consuming and subjective process. This can be particularly problematic because of the use of valuable samples for isolation and the large consumption of solvents in preparative scale. These processes could be improved by using statistical computations to save time, solvent and experimental efforts. Thus, contributed by ESI-MS, after applying DryLab software to gain an overview of the most effective parameters in separation of synthesized celecoxib and its co-eluted compounds, design of experiment software that relies on multivariate modeling as a chemometric approach was used to predict the optimized touching-band overloading conditions by objective functions according to the relationship between selectivity and stationary phase properties. The loadability of the method was investigated on the analytical and semi-preparative scales, and the performance of this chemometric approach was approved by peak shapes beside recovery and purity of products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Chromatographic methods for determination of S-substituted cysteine derivatives--a comparative study.

    PubMed

    Kubec, Roman; Dadáková, Eva

    2009-10-09

    A novel HPLC method for determination of a wide variety of S-substituted cysteine derivatives in Allium species has been developed and validated. This method allows simultaneous separation and quantification of S-alk(en)ylcysteine S-oxides, gamma-glutamyl-S-alk(en)ylcysteines and gamma-glutamyl-S-alk(en)ylcysteine S-oxides in a single run. The procedure is based on extraction of these amino acids and dipeptides by methanol, their derivatization by dansyl chloride and subsequent separation by reversed phase HPLC. The main advantages of the new method are simplicity, excellent stability of derivatives, high sensitivity, specificity and the ability to simultaneously analyze the whole range of S-substituted cysteine derivatives. This method was critically compared with other chromatographic procedures used for quantification of S-substituted cysteine derivatives, namely with two other HPLC methods (derivatization by o-phthaldialdehyde/tert-butylthiol and fluorenylmethyl chloroformate), and with determination by gas chromatography or capillary electrophoresis. Major advantages and drawbacks of these analytical procedures are discussed. Employing these various chromatographic methods, the content and relative proportions of individual S-substituted cysteine derivatives were determined in four most frequently consumed alliaceous vegetables (garlic, onion, shallot, and leek).

  3. Development of green extraction processes for Nannochloropsis gaditana biomass valorization.

    PubMed

    Sánchez-Camargo, Andrea Del Pilar; Pleite, Natalia; Mendiola, José Antonio; Cifuentes, Alejandro; Herrero, Miguel; Gilbert-López, Bienvenida; Ibáñez, Elena

    2018-04-23

    In the present work, the valorization of Nannochloropsis gaditana biomass is proposed within the concept of biorefinery. To this aim, high-pressure homogenization (HPH) was used to break down the strong cell wall and supercritical fluid extraction (SFE) with pure CO 2 was applied as a first step to extract valuable compounds (such as non-polar lipids and pigments). Extraction of the remaining residue for the recovery of bioactive compounds was studied by means of an experimental design based on response surface methodology (RSM) employing pressurized liquid extraction (PLE) with green solvents such as water and ethanol. Optimum extract was achieved with pure ethanol at 170°C for 20 min, providing an important antioxidant capacity (0.72 ± 0.03 mmol trolox eq g -1 extract). Complete chemical characterization of the optimum extract was carried out by using different chromatographic methods such as reverse-phase high-performance liquid chromatography with diode array detection (RP-HPLC-DAD), normal-phase HPLC with evaporative light scattering detection (NP-HPLC-ELSD) and gas chromatography coupled to mass spectrometry detection (GC-MS); carotenoids (e.g. violaxanthin), chlorophylls and polar lipids were the main compounds observed while palmitoleic, palmitic, myristic acids and the polyunsaturated eicosapentanoic (EPA) acid were the predominant fatty acids in all PLE extracts. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Stability-indicating method for simultaneous estimation of olmesartan medoxomile, amlodipine besylate and hydrochlorothiazide by RP-HPLC in tablet dosage form.

    PubMed

    Jain, P S; Patel, M K; Gorle, A P; Chaudhari, A J; Surana, S J

    2012-09-01

    A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 µm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 µg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 µg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.

  5. Application of HPLC with ELSD Detection for the Assessment of Azelaic Acid Impurities in Liposomal Formulation

    PubMed Central

    Han, Stanislaw; Karlowicz-Bodalska, Katarzyna; Ozimek, Lukasz

    2013-01-01

    In the course of research and development of a new pharmaceutical formulation of azelaic acid in the liposomal form, we developed a rapid and accurate method for the detection of impurities using high-performance liquid chromatography. A chromatographic column from Merck (Purospher Star RP C18, 250–4 mm (5 μm) was used in the assay, and the mobile phase gradient consisted of three phases: A—methanol : water (5 : 95) + 1.5% (v/v) acetic acid; B—water : methanol (5 : 95) + 1.5% (v/v) acetic acid; and C—chloroform. Detection of the impurities and the active substance was performed by an evaporative light-scattering detector. The method was validated for selectivity, system precision, method precision, limit of detection, and response rates. The proposed method can be used to detect impurities in the liposomal formulation of azelaic acid. The method enables separation of azelaic acid from the identified and unidentified impurities and from the excipients used in the drug form. PMID:24228008

  6. Application of HPLC with ELSD detection for the assessment of azelaic acid impurities in liposomal formulation.

    PubMed

    Han, Stanislaw; Karlowicz-Bodalska, Katarzyna; Szura, Dorota; Ozimek, Lukasz; Musial, Witold

    2013-01-01

    In the course of research and development of a new pharmaceutical formulation of azelaic acid in the liposomal form, we developed a rapid and accurate method for the detection of impurities using high-performance liquid chromatography. A chromatographic column from Merck (Purospher Star RP C18, 250-4 mm (5 μm) was used in the assay, and the mobile phase gradient consisted of three phases: A--methanol : water (5 : 95) + 1.5% (v/v) acetic acid; B--water : methanol (5 : 95) + 1.5% (v/v) acetic acid; and C--chloroform. Detection of the impurities and the active substance was performed by an evaporative light-scattering detector. The method was validated for selectivity, system precision, method precision, limit of detection, and response rates. The proposed method can be used to detect impurities in the liposomal formulation of azelaic acid. The method enables separation of azelaic acid from the identified and unidentified impurities and from the excipients used in the drug form.

  7. A Simple RP-HPLC Method for Quantitation of Itopride HCl in Tablet Dosage Form.

    PubMed

    Thiruvengada, Rajan Vs; Mohamed, Saleem Ts; Ramkanth, S; Alagusundaram, M; Ganaprakash, K; Madhusudhana, Chetty C

    2010-10-01

    An isocratic reversed phase high-performance liquid chromatographic method with ultraviolet detection at 220 nm has been developed for the quantification of itopride hydrochloride in tablet dosage form. The quantification was carried out using C(8) column (250 mm × 4.6 mm), 5-μm particle size SS column. The mobile phase comprised of two solvents (Solvent A: buffer 1.4 mL ortho-phosphoric acid adjusted to pH 3.0 with triethyl amine and Solvent B: acetonitrile). The ratio of Solvent A: Solvent B was 75:25 v/v. The flow rate was 1.0 mL (-1)with UV detection at 220 nm. The method has been validated and proved to be robust. The calibration curve was linear in the concentration range of 80-120% with coefficient of correlation 0.9995. The percentage recovery for itopride HCl was 100.01%. The proposed method was validated for its selectivity, linearity, accuracy, and precision. The method was found to be suitable for the quality control of itopride HCl in tablet dosage formulation.

  8. A Simple RP-HPLC Method for Quantitation of Itopride HCl in Tablet Dosage Form

    PubMed Central

    Thiruvengada, Rajan VS; Mohamed, Saleem TS; Ramkanth, S; Alagusundaram, M; Ganaprakash, K; Madhusudhana, Chetty C

    2010-01-01

    An isocratic reversed phase high-performance liquid chromatographic method with ultraviolet detection at 220 nm has been developed for the quantification of itopride hydrochloride in tablet dosage form. The quantification was carried out using C8 column (250 mm × 4.6 mm), 5-μm particle size SS column. The mobile phase comprised of two solvents (Solvent A: buffer 1.4 mL ortho-phosphoric acid adjusted to pH 3.0 with triethyl amine and Solvent B: acetonitrile). The ratio of Solvent A: Solvent B was 75:25 v/v. The flow rate was 1.0 mL -1with UV detection at 220 nm. The method has been validated and proved to be robust. The calibration curve was linear in the concentration range of 80-120% with coefficient of correlation 0.9995. The percentage recovery for itopride HCl was 100.01%. The proposed method was validated for its selectivity, linearity, accuracy, and precision. The method was found to be suitable for the quality control of itopride HCl in tablet dosage formulation. PMID:21264104

  9. Fourth-derivative synchronous spectrofluorimetry and HPLC with fluorescence detection as two analytical techniques for the simultaneous determination of itopride and domperidone.

    PubMed

    Ibrahim, Fawzia; Nasr, Jenny Jeehan

    2016-02-01

    Two simple, rapid and sensitive methods, namely, fourth-derivative synchronous spectrofluorimetry (method I) and HPLC with fluorescence detection (method II) were developed for the simultaneous analysis of a binary mixture of itopride HCl (ITP) and domperidone (DOM) without prior separation. The first method was based on measuring the fourth derivative of the synchronous fluorescence spectra of the two drugs at Δλ = 40 nm in methanol. The different experimental parameters affecting the synchronous fluorescence of the studied drugs were carefully optimized. Chromatographic separation was performed in < 6.0 min using a RP C18 column (250 mm × 4.6 mm i.d., 5 µm particle size) with fluorescence detection at 344 nm after excitation at 285 nm. A mobile phase composed of a mixture of 0.02 M phosphate buffer with acetonitrile in a ratio of 55 : 45, pH 4.5, was used at a flow rate of 1 mL/min. Linearity ranges were found to be 0.1-2 µg/mL for ITP in both methods, whereas those for DOM were found to be 0.08-2 and 0.05-1.5 µg/mL in methods I and II, respectively. The proposed methods were successfully applied for the determination of the studied drugs in synthetic mixtures and laboratory-prepared tablets. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Detection and quantification of the selective EP4 receptor antagonist CJ-023423 (grapiprant) in canine plasma by HPLC with spectrofluorimetric detection.

    PubMed

    Vito, Virgina De; Saba, Alessandro; Lee, Hong-Ki; Owen, Helen; Poapolathep, Amnart; Giorgi, Mario

    2016-01-25

    Grapiprant, a novel pharmacologically active ingredient, acts as a selective EP4 receptor antagonist whose physiological ligand is prostaglandin E2 (PGE2). It is currently under development for use in humans and dogs for the control of pain and inflammation associated with osteoarthritis. The aim of the present study was to develop an easy and sensitive method to quantify grapiprant in canine plasma and to apply the method in a canine patient. Several parameters, both in the extraction and detection method were evaluated. The final mobile phase consisted of ACN:AcONH4 (20 mM) solution, pH 4 (70:30, v/v) at a flow rate of 1 mL/min. The elution of grapiprant and IS (metoclopramide) was carried out in isocratic mode through a Synergi Polar-RP 80A analytical column (150 mm × 4.6 mm). The best excitation and emission wavelengths were 320 and 365 nm, respectively. Grapiprant was extracted from the plasma using CHCl3, which gave a recovery of 88.1 ± 10.22% and a lower limit of quantification (LLOQ) of 10 ng/mL. The method was validated in terms of linearity, limit of detection (LOD), LLOQ, selectivity, accuracy and precision, extraction recovery, stability, and inter-laboratory cross validation, according to international guidelines. The chromatographic runs were specific with no interfering peaks at the retention times of the analyte and IS, as confirmed by HPLC-MS experiments. In conclusion, this was a simple and effective method using HPLC-FL to detect grapiprant in plasma, which may be useful for future pharmacokinetic studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Unambiguous detection of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana).

    PubMed

    Grynbaum, Marc David; Hentschel, Petra; Putzbach, Karsten; Rehbein, Jens; Krucker, Manfred; Nicholson, Graeme; Albert, Klaus

    2005-09-01

    HPLC atmospheric pressure chemical ionization (APCI)/MS, GC MS, HPLC diode array detection (DAD), and NMR were used for the identification of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana). Matrix solid phase dispersion was applied for the extraction of the carotenoids. This gentle and expeditious extraction technique for solid and viscous samples leads to distinct higher enrichment rates than the conventional liquid-liquid extraction. The chromatographic separation was achieved employing a C30 RP column that allows the separation of shape-constrained geometrical isomers. A methanol/tert-butylmethyl ether/water gradient was applied. (all-E) Astaxanthin and the geometrical isomers were identified by HPLC APCI/MS, by coelution with isomerized authentical standard, by UV spectroscopy (DAD), and three isomers were unambiguously assigned by microcoil NMR spectroscopy. In this method, microcoils are transversally aligned to the magnetic field and have an increased sensitivity compared to the conventional double-saddle Helmholtz coils, thus enabling the measurement on small samples. The carotenol fatty acid esters were saponified enzymatically with Lipase type VII from Candida rugosa. The fatty acids were detected by GC MS after transesterification, but also without previous derivatization by HPLC APCI/MS. C14:0, C16:0, C16:1, C18:1, C20:0, C20:5, and C22:6 were found in astaxanthin monoesters and in astaxanthin diesters. (all-E) Astaxanthin was identified as the main isomer in six fatty acid ester fractions by NMR. Quantitation was carried out by the method of internal standard. (13-cis) Astaxanthin (70 microg/g), 542 microg/g (all-E) astaxanthin, 36 microg/g unidentified astaxanthin isomer, 62 microg/g (9-cis) astaxanthin, and 7842 microg/g astaxanthin fatty acid esters were found.

  12. Development and validation of a stability-indicating RP-HPLC method for determination of atomoxetine hydrochloride in tablets.

    PubMed

    Patel, Sejal K; Patel, Natvarlal J

    2010-01-01

    This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) by using acetonitrile-methanol-0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40 degrees C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.5-5 microg/mL with a mean recovery of 100.8 +/- 0.4% for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.

  13. Development and Validation of a Stability-Indicating RP-HPLC Method for Duloxetine Hydrochloride in its Bulk and Tablet Dosage Form

    PubMed Central

    Chhalotiya, Usmangani K.; Bhatt, Kashyap K.; Shah, Dimal A.; Baldania, Sunil L.

    2010-01-01

    The objective of the present work was to develop a stability-indicating RP-HPLC method for duloxetine hydrochloride (DUL) in the presence of its degradation products generated from forced decomposition studies. The drug substance was found to be susceptible to stress conditions of acid hydrolysis. The drug was found to be stable to dry heat, photodegradation, oxidation and basic condition attempted. Successful separation of the drug from the degradation products formed under acidic stress conditions was achieved on a Hypersil C-18 column (250 mm × 4.6 mm id, 5μm particle size) using acetonitrile: 0.01 M potassium dihydrogen phosphate buffer (pH 5.4 adjusted with orthophosphoric acid) (50:50, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Quantification was achieved with photodiode array detection at 229 nm over the concentration range 1–25 μg/ml with range of recovery 99.8–101.3 % for DUL by the RP-HPLC method. Statistical analysis proved the method to be repeatable, specific, and accurate for estimation of DUL. It can be used as a stability-indicating method due to its effective separation of the drug from its degradation products, PMID:21179321

  14. Determination of itopride hydrochloride in human plasma by RP-HPLC with fluorescence detection and its use in bioequivalence study.

    PubMed

    Ma, Jing; Yuan, Li-Hua; Ding, Mei-Juan; Zhang, Jun; Zhang, Qing; Xu, Qun-Wei; Zhou, Xue-Min

    2009-03-01

    A sensitive, selective and simple method using a precipitation of protein with 10% perchloric acid, followed by high-performance liquid chromatography (HPLC) with fluorescence detection was developed for the determination of itopride hydrochloride in human plasma, using levofloxacin as the internal standard (IS). Chromatographic separation was obtained within 7.0 min using a reverse phase Hypersil BDS C(18) (250 mm x 4.6 mm, 5 microm) column and an isocratic mobile phase, constituting of a mixture of 0.1 mol/l ammonium acetate-methanol (30:70, v/v) flowing at 1.1 ml/min. The excitation and emission wavelengths were set at 304 and 344 nm, respectively. The method was validated over the concentration range of 5 ng/ml to 1000.0 ng/ml. The lower limit of quantitation (LLOQ) was 5 ng/ml. The extractive recovery of itopride hydrochloride from the biological matrix was more than 80.77%. The intra-day accuracy of the drug containing serum samples was more than 82.94% with a precision of 2.81-4.37%. The inter-day accuracy was 82.91% or more, with a precision of 6.89-9.54%. The limit we have used (70-143%) is based on the local regulatory authority (SFDA). The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.

  15. New validated method for piracetam HPLC determination in human plasma.

    PubMed

    Curticapean, Augustin; Imre, Silvia

    2007-01-10

    The new method for HPLC determination of piracetam in human plasma was developed and validated by a new approach. The simple determination by UV detection was performed on supernatant, obtained from plasma, after proteins precipitation with perchloric acid. The chromatographic separation of piracetam under a gradient elution was achieved at room temperature with a RP-18 LiChroSpher 100 column and aqueous mobile phase containing acetonitrile and methanol. The quantitative determination of piracetam was performed at 200 nm with a lower limit of quantification LLQ=2 microg/ml. For this limit, the calculated values of the coefficient of variation and difference between mean and the nominal concentration are CV%=9.7 and bias%=0.9 for the intra-day assay, and CV%=19.1 and bias%=-7.45 for the between-days assay. For precision, the range was CV%=1.8/11.6 in the intra-day and between-days assay, and for accuracy, the range was bias%=2.3/14.9 in the intra-day and between-days assay. In addition, the stability of piracetam in different conditions was verified. Piracetam proved to be stable in plasma during 4 weeks at -20 degrees C and for 36 h at 20 degrees C in the supernatant after protein precipitation. The new proposed method was used for a bioequivalence study of two medicines containing 800 mg piracetam.

  16. Molecular characterization and bio-functional property determination using SDS-PAGE and RP-HPLC of protein fractions from two Nigella species.

    PubMed

    Alu'datt, Muhammad H; Rababah, Taha; Alhamad, Mohammad N; Alodat, Moh'd; Al-Mahasneh, Majdi A; Gammoh, Sana; Ereifej, Khalil; Almajwal, Ali; Kubow, Stan

    2017-09-01

    This study aimed to investigate the molecular and bio-functional properties of protein fractions from Nigella damascena and Nigella arvensis, including the albumin, globulin, glutein-1, glutein-2 and prolamin fractions. Protein subunits were not observed in globulin and prolamin fractions. No peaks appeared in RP-HPLC chromatograms of globulin for either species. Two predominant peaks were observed in the RP-HPLC profiles of all protein fractions. Proteins separated by RP-HPLC have potential inhibitory and antioxidant activities in all fractions. Optimum ACE-inhibitory and antioxidant activities of proteins separated by RP-HPLC were observed in glutein-2 and albumin, respectively, for both species. For pepsin and combined pepsin-trypsin hydrolyses, the highest degree of hydrolysis (DH) was obtained in glutein-2 fraction of Nigella arvensis. Highest ACE-inhibitory activity of hydrolyzed protein fractions was found at 4h via pepsin hydrolysis in globulin fraction of Nigella damascena. Highest antioxidant activities of hydrolyzed protein fractions were found in glutelin-2 for both species. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Development and validation of an RP-HPLC method for quantitative determination of vanillin and related phenolic compounds in Vanilla planifolia.

    PubMed

    Sinha, Arun Kumar; Verma, Subash Chandra; Sharma, Upendra Kumar

    2007-01-01

    A simple and fast method was developed using RP-HPLC for separation and quantitative determination of vanillin and related phenolic compounds in ethanolic extract of pods of Vanilla planifolia. Ten phenolic compounds, namely 4-hydroxybenzyl alcohol, vanillyl alcohol, 3,4-dihydroxybenzaldehyde, 4-hydroxybenzoic acid, vanillic acid, 4-hydroxybenzaldehyde, vanillin, p-coumaric acid, ferulic acid, and piperonal were quantitatively determined using ACN, methanol, and 0.2% acetic acid in water as a mobile phase with a gradient elution mode. The method showed good linearity, high precision, and good recovery of compounds of interest. The present method would be useful for analytical research and for routine analysis of vanilla extracts for their quality control.

  18. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    PubMed Central

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  19. Reverse-phase HPLC analysis of human alpha crystallin.

    PubMed

    Swamy, M S; Abraham, E C

    1991-03-01

    A rapid and highly sensitive reverse-phase HPLC (RP-HPLC) method was used to separate crystallin subunits from human alpha crystallin. Three distinct peaks were separated; by electrophoretic and immunological analyses the first and second peaks were identified as alpha B and alpha A respectively. On the other hand, peak 3 appeared to be a modified form of alpha crystallin. The ratio of alpha A and alpha B proteins was 3:1 in 1 day old lenses which gradually changed to 2:1 in 17 year old lenses and to 1:1 in the 50 and 82 year old whole lenses and 82 year old lens cortex, with a concomitant increase in the modified alpha, suggesting that alpha A subunits are relatively more involved in aggregation. Analysis of the 82 year old lens nucleus also supported this conclusion. The RP-HPLC analysis of the HMW aggregate fraction showed substantial enrichment of the modified alpha. The alpha A and alpha B subunits independently reassociated to form polymeric alpha crystallin whereas the modified alpha reassociated to form HMW aggregates as shown by molecular sieve HPLC. Hence it appears that the HMW aggregate peak was constituted by modified alpha crystallin. Only in the peak 3 material the 280 nm absorbance was about 2-fold higher than what was expected from the actual protein content. The data suggest that the changes induced by post-translational modifications may have some role in the formation of modified alpha. The present RP-HPLC method is useful in separating these modified alpha from the unmodified alpha A and alpha B subunits.

  20. [HPLC specific chromatogram of Dendrobium officinale].

    PubMed

    Yan, Mei-Qiu; Chen, Su-Hong; Lv, Gui-Yuan; Zhou, Gui-Fen; Liu, Xia

    2013-02-01

    To establish the method of specific chromatogram analysis of ether extract of Dendrobium officinale for identification of D. officinale. Chromatographic separation was carried out at 30 degrees C on an Ultimate C18 column (4.6 mm x 250 mm, 5 microm) eluted with methanol and water containing 0.2% phosphoric acid in a gradient elution at a flow rate of 1.0 mL x min(-1). The detection wavelength was set at 280 nm. The similarity evaluation system for chromatographic fingerprint of NPC (National Pharmacopoeia Committee) was adopted to specific chromatogram construction. The HPLC specific chromatogram of D. officinale was constructed with 6 common specific chromatographic peaks including naringenin as a reference peak. The method shows good precision and repeatability of relative retention time. It can be used to identify D. officinale.

  1. Direct injection analysis of fatty and resin acids in papermaking process waters by HPLC/MS.

    PubMed

    Valto, Piia; Knuutinen, Juha; Alén, Raimo

    2011-04-01

    A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Novel HPLC-UV Method for Simultaneous Determination of Fat-soluble Vitamins and Coenzyme Q10 in Medicines and Supplements.

    PubMed

    Temova-Rakuša, Žane; Srečnik, Eva; Roškar, Robert

    2017-09-01

    A precise, accurate and rapid HPLC-UV method for simultaneous determination of fat-soluble vitamins (vitamin D3, E-acetate, K1, β-carotene, A-palmitate) and coenzyme Q10 was developed and validated according to ICH guidelines. Optimal chromatographic separation of the analytes in minimal analysis time (8 min) was achieved on a Luna C18 150 × 4.6 mm column using a mixture of acetonitrile, tetrahydrofuran and water (50:45:5, v/v/v). The described reversed phase HPLC method is the first published for quantification of these five fat-soluble vitamins and coenzyme Q10 within a single chromatographic run. The method was further applied for quantification of the analytes in selected liquid and solid dosage forms, registered as nutritional supplements and prescription medicines, which confirmed its suitability for routine analysis.

  3. Crocheted ETFE-reactor for on-line post-column photoderivatization of diclofenac in high-performance liquid chromatography.

    PubMed

    Kuhlmann, O; Krauss, G J

    1997-12-01

    A sensitive and selective bioanalytical method for diclofenac using reversed-phase HPLC and fluorescence detection is described. Diclofenac was detected as its fluorescent derivative after on-line post-column photoderivatization. Irradiation with UV light of diclofenac in aqueous solutions leads to the sequential loss of both chlorine substituents and ring closure. The major product, carbazole-1-acetic acid, was detected by a fluorescence detector using an excitation wavelength of 286 nm and an emission wavelength of 360 nm. The self-made reactor was a crocheted ethylene and tetrafluoroethylene (ETFE, named TEFZEL) capillary, 20 m in length, wound directly around a 253.7 nm UV lamp. The capillary was crocheted in order to overcome peak widening. Chromatographic separation was achieved by using a Regis SPS 100 RP-8 column (5 microm; 150 mm x 4.6 mm i.d.) and a LiChrospher 100 RP-18 (5 microm) guard column from E. Merck. The detection limit was 1 ng ml(-1) at an injection volume of 20 microl. Daily relative standard deviations (RSD) were 5.5%, (73 ng diclofenac/ml, n = 9), and 5.1% (405 ng diclofenac/ml, n = 6), respectively. Chromatograms of human aqueous humor and human serum containing diclofenac, and figures showing the time dependent increase/decrease of the photoderivatization product, are shown.

  4. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica

    PubMed Central

    Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748

  5. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    PubMed

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.

  6. RP-HPLC×HILIC chromatography for quantifying ertapenem sodium with a look at green chemistry.

    PubMed

    Pedroso, Tahisa M; Medeiros, Ana C D; Salgado, Herida R N

    2016-11-01

    Ertapenem sodium is a polar and ionizable compound; therefore, it has little retention on traditional C18 columns in reverse-phase high-performance liquid chromatography, even using a highly-aqueous mobile phase that can result in dewetting in the stationary phase. Thus, the most coherent process for ERTM is to develop a method for Hydrophilic Interaction Chromatography. However, for the traditional methods in HILIC, the use of a highly organic mobile phase is necessary; usually an amount exceeding 80% acetonitrile is necessary. On the other hand, the RP-HPLC mode is considered for the analysis technique, which is more often used for quantification of substances, and new columns are often introduced to analyze different groups of compounds. Two new analytical methods have been developed for routine analysis. The proposed chromatographic method was adequate and advantageous by presenting simplicity, linearity, precision, accuracy, robustness, detection limits, and satisfactory quantification. Analytical methods are constantly undergoing changes and improvements. Researchers worldwide are rapidly adopting Green Chemistry. The development of new pharmaceutical methods based in Green chemistry has been encouraged by universities and the pharmaceutical industry. Issues related to green chemistry are in evidence and they have been featured in international journals of high impact. The methods described here have economic advantages and they feature an eco-friendly focus, which is discussed in this work. This work was developed with an environmental conscience, always looking to minimize the possible generated organic waste. Therefore, discussion on this aspect is included. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Development and Validation of Liquid Chromatographic Method for Estimation of Naringin in Nanoformulation

    PubMed Central

    Musmade, Kranti P.; Trilok, M.; Dengale, Swapnil J.; Bhat, Krishnamurthy; Reddy, M. S.; Musmade, Prashant B.; Udupa, N.

    2014-01-01

    A simple, precise, accurate, rapid, and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection has been developed and validated for quantification of naringin (NAR) in novel pharmaceutical formulation. NAR is a polyphenolic flavonoid present in most of the citrus plants having variety of pharmacological activities. Method optimization was carried out by considering the various parameters such as effect of pH and column. The analyte was separated by employing a C18 (250.0 × 4.6 mm, 5 μm) column at ambient temperature in isocratic conditions using phosphate buffer pH 3.5: acetonitrile (75 : 25% v/v) as mobile phase pumped at a flow rate of 1.0 mL/min. UV detection was carried out at 282 nm. The developed method was validated according to ICH guidelines Q2(R1). The method was found to be precise and accurate on statistical evaluation with a linearity range of 0.1 to 20.0 μg/mL for NAR. The intra- and interday precision studies showed good reproducibility with coefficients of variation (CV) less than 1.0%. The mean recovery of NAR was found to be 99.33 ± 0.16%. The proposed method was found to be highly accurate, sensitive, and robust. The proposed liquid chromatographic method was successfully employed for the routine analysis of said compound in developed novel nanopharmaceuticals. The presence of excipients did not show any interference on the determination of NAR, indicating method specificity. PMID:26556205

  8. [Determination of canthaxanthin and astaxanthin in egg yolks by reversed phase high performance liquid chromatography with diode array detection].

    PubMed

    He, Kang-Hao; Zou, Xiao-Li; Liu, Xiang; Zeng, Hong-Yan

    2012-01-01

    A method using reversed phase high performance liquid chromatography (RP-HPLC) coupled with diode array detector (DAD) was developed for the simultaneous determination of canthaxanthin and astaxanthin in egg yolks. Samples were extracted with acetonitrile in ultrasonic bath for 20 minutes and then purified by freezing-lipid filtration and solid phase extraction (SPE). After being vaporized to dryness by nitrogen blowing and made up to volume with methanol, the extract solution was chromatographically separated in C18 column with a unitary mobile phase consisting of acetonitrile. The proposed method was validated in terms of linearity, precision, accuracy, and limit of detection (LOD). Regression analysis revealed a good linearity between peak area of each analyte and its concentration (r > or = 0.998). The intra- and inter-day relative standard deviations (RSDs) were less than 3.6% and 5.2%, respectively. LODs of canthaxanthin and astaxanthin were 0.035 and 0.027 microg/mL (S/N = 3). The average recoveries of canthaxanthin and astaxanthin were 91.5% and 88.7%. The proposed method is simple, fast and easy to apply.

  9. High throughput screening of active pharmaceutical ingredients by UPLC.

    PubMed

    Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun

    2008-07-01

    Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.

  10. Multivariate analysis of organic acids in fermented food from reversed-phase high-performance liquid chromatography data.

    PubMed

    Mortera, Pablo; Zuljan, Federico A; Magni, Christian; Bortolato, Santiago A; Alarcón, Sergio H

    2018-02-01

    Multivariate calibration coupled to RP-HPLC with diode array detection (HPLC-DAD) was applied to the identification and the quantitative evaluation of the short chain organic acids (malic, oxalic, formic, lactic, acetic, citric, pyruvic, succinic, tartaric, propionic and α-cetoglutaric) in fermented food. The goal of the present study was to get the successful resolution of a system in the combined occurrence of strongly coeluting peaks, of distortions in the time sensors among chromatograms, and of the presence of unexpected compounds not included in the calibration step. Second-order HPLC-DAD data matrices were obtained in a short time (10min) on a C18 column with a chromatographic system operating in isocratic mode (mobile phase was 20mmolL -1 phosphate buffer at pH 2.20) and a flow-rate of 1.0mLmin -1 at room temperature. Parallel factor analysis (PARAFAC) and unfolded partial least-squares combined with residual bilinearization (U-PLS/RBL) were the second-order calibration algorithms select for data processing. The performance of the analytical parameters was good with an outstanding limit of detection (LODs) for acids ranging from 0.15 to 10.0mmolL -1 in the validation samples. The improved method was applied to the analysis of many dairy products (yoghurt, cultured milk and cheese) and wine. The method was shown as an effective means for determining and following acid contents in fermented food and was characterized by reducibility with simple, high resolution and rapid procedure without derivatization of analytes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Stability-indicating RP-HPLC method for the simultaneous determination of escitalopram oxalate and clonazepam.

    PubMed

    Kakde, Rajendra B; Satone, Dinesh D; Gadapayale, Kamalesh K; Kakde, Megha G

    2013-07-01

    The objective of the current study was to develop a validated, specific stability-indicating reversed-phase liquid chromatographic (LC) method for the quantitative determination of escitalopram oxalate and clonazepam and their related substances in bulk drugs and pharmaceutical dosage forms in the presence of degradation products. Forced degradation studies were performed on the pure drugs of escitalopram oxalate and clonazepam, as per the stress conditions prescribed by the International Conference on Harmonization (ICH) using acid, base, oxidation, thermal stress and photolytic degradation to show the stability-indicating power of the method. Significant degradation was observed during acid and alkaline hydrolysis and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies. Good resolution between the peaks corresponded to the active pharmaceutical ingredients, escitalopram oxalate and clonazepam, and degradation products from the analyte were achieved on an ODS Hypersil C18 column (250 × 4.6 mm) using a mobile phase consisting of a mixture of acetonitrile-50 mM phosphate buffer + 10 mM triethylamine (70:30, v/v). The detection was conducted at 268 nm. The limit of detection and the limit of quantitation for escitalopram oxalate and clonazepam were established. The stress test solutions were assayed against the qualified working standards of escitalopram oxalate and clonazepam, which indicated that the developed LC method was stability-indicating. Validation of the developed LC method was conducted as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of escitalopram oxalate and clonazepam.

  12. [Determination of aristolochic acid A in Guanxinsuhe preparations by RP-HPLC].

    PubMed

    Li, Lin; Gao, Hui-Min; Wang, Zhi-Min; Wang, Wei-Hao

    2006-01-01

    To establish a determination method of aristolochic acid A in Guanxisuhe preparations by RP-HPLC. The instrument used was Hewlett-Packard 1100 HPLC with a Alltech C18 column (4.6 mm x 250 mm, 5 microm). The mobile phase was methanol-water-acetic acid (68: 32:1) and the flow rate was 1.0 mL x min(-1). The UV detection wavelength was 390 nm and the column temperature was at 35 degrees C. The extracted solvent for the preparations was methanol solution contained 10% formic acid. The calibration curve was linear (r = 0.999 9) within the range of 0.119-1.89 microg for aristolochic acid A. The average recovery 99.0%, RSD 0.63%. The method with good linear relationship was convenient, quick, accurate, and suitable for the quality control of the aristolochic acid A in Guanxinsuhe and other traditional Chinese medicines containing aristolochic acid A.

  13. Validation of a RP-HPLC-DAD Method for Chamomile (Matricaria recutita) Preparations and Assessment of the Marker, Apigenin-7-glucoside, Safety and Anti-Inflammatory Effect

    PubMed Central

    Miguel, Felipe Galeti; Spinola, Nathália Favaretto; Ribeiro, Diego Luis; Barcelos, Gustavo Rafael Mazzaron; Antunes, Lusânia Maria Greggi; Hori, Juliana Issa; Marquele-Oliveira, Franciane; Rocha, Bruno Alves; Berretta, Andresa Aparecida

    2015-01-01

    Chamomile is a medicinal plant, which presents several biological effects, especially the anti-inflammatory effect. One of the compounds related to this effect is apigenin, a flavonoid that is mostly found in its glycosylated form, apigenin-7-glucoside (APG), in natural sources. However, the affectivity and safety of this glycoside have not been well explored for topical application. In this context, the aim of this work was to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC-DAD) method to quantify APG in chamomile preparations. Additionally, the safety and the anti-inflammatory potential of this flavonoid were verified. The RP-HPLC-DAD method was developed and validated with linearity at 24.0–36.0 μg/mL range (r = 0.9994). Intra- and interday precision (RSD) were 0.27–2.66% and accuracy was 98.27–101.21%. The validated method was applied in the analysis of chamomile flower heads, glycolic extract, and Kamillen cream, supporting the method application in the quality control of chamomile preparations. Furthermore, the APG safety was assessed by MTT cytotoxicity assay and mutagenic protocols and the anti-inflammatory activity was confirmed by a diminished TNF-α production showed by mice macrophages treated with APG following LPS treatment. PMID:26421053

  14. Detection of indomethacin by high-performance liquid chromatography with in situ electrogenerated Mn(III) chemiluminescence detection.

    PubMed

    Zhang, Yantu; Zhang, Zhujun; Qi, Guangcai; Sun, Yonghua; Wei, Yue; Ma, Hongyan

    2007-01-23

    The determination of indomethacin (INM) in pharmaceutical and biological samples by means of high-performance liquid chromatography (HPLC) with in situ electrogenerated Mn(III) chemiluminescence (CL) detection was proposed. The method was based on the direct CL reaction of INM and Mn(III), which was in situ electrogenerated by constant current electrolysis. The chromatographic separation was carried out on Nucleosil RP-C(18) column (250 mm x 4.6 mm; i.d., 5 microm; pore size, 100 A) at 20 degrees C. The mobile phase consisted of methanol:water:acetic acid=67:33:0.1 solution. At a flow rate of 1.0 mL min(-1), the total run time was 10 min. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Under the optimal conditions, a linear range from 0.01 to 10 microg mL(-1)(R(2)=0.9991), and a detection limit of 8 ng mL(-1) (signal-to-noise ratio=3) for INM were achieved. The relative standard deviations (R.S.D.) for 0.1 microg mL(-1) INM were 2.2% within a day (n=11) and 3.0% on 5 consecutive days (n=6), respectively. The recovery of INM from urine samples was more than 92%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.

  15. Rapid determination of human globin chains using reversed-phase high-performance liquid chromatography.

    PubMed

    Wan, Jun-Hui; Tian, Pei-Ling; Luo, Wei-Hao; Wu, Bing-Yi; Xiong, Fu; Zhou, Wan-Jun; Wei, Xiang-Cai; Xu, Xiang-Min

    2012-07-15

    Reversed-phase high-performance liquid chromatography (RP-HPLC) of human globin chains is an important tool for detecting thalassemias and hemoglobin variants. The challenges of this method that limit its clinical application are a long analytical time and complex sample preparation. The aim of this study was to establish a simple, rapid and high-resolution RP-HPLC method for the separation of globin chains in human blood. Red blood cells from newborns and adults were diluted in deionized water and injected directly onto a micro-jupiter C18 reversed-phase column (250 mm × 4.6 mm) with UV detection at 280 nm. Under the conditions of varying pH or the HPLC gradient, the globin chains (pre-β, β, δ, α, (G)γ and (A)γ) were denatured and separated from the heme groups in 12 min with a retention time coefficient of variation (CV) ranging from 0.11 to 1.29% and a peak area CV between 0.32% and 4.86%. Significant differences (P<0.05) among three groups (normal, Hb H and β thalassemia) were found in the area ratio of α/pre-β+β applying the rapid elution procedure, while P≥0.05 was obtained between the normal and α thalassemia silent/trait group. Based on the ANOVA results, receiver operating characteristic (ROC) curve analysis of the δ/β and α/pre-β+β area ratios showed a sensitivity of 100.0%, and a specificity of 100.0% for indicating β thalassemia carriers, and a sensitivity of 96.6% and a specificity of 89.6% for the prediction of hemoglobin H (Hb H) disease. The proposed cut-off was 0.026 of δ/β for β thalassemia carriers and 0.626 of α/pre-β+β for Hb H disease. In addition, abnormal hemoglobin hemoglobin E (Hb E) and Hb Westmead (Hb WS) were successfully identified using this RP-HPLC method. Our experience in developing this RP-HPLC method for the rapid separation of human globin chains could be of use for similar work. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Simple and rapid high-performance liquid chromatographic method for the determination of aspartame and its metabolites in foods.

    PubMed

    Gibbs, B F; Alli, I; Mulligan, C N

    1996-02-23

    A method for the determination of aspartame (N-L-alpha-aspartyl-L-phenylalanine methyl ester) and its metabolites, applicable on a routine quality assurance basis, is described. Liquid samples (diet Coke, 7-Up, Pepsi, etc.) were injected directly onto a mini-cartridge reversed-phase column on a high-performance liquid chromatographic system, whereas solid samples (Equal, hot chocolate powder, pudding, etc.) were extracted with water. Optimising chromatographic conditions resulted in resolved components of interest within 12 min. The by-products were confirmed by mass spectrometry. Although the method was developed on a two-pump HPLC system fitted with a diode-array detector, it is straightforward and can be transformed to the simplest HPLC configuration. Using a single-piston pump (with damper), a fixed-wavelength detector and a recorder/integrator, the degradation of products can be monitored as they decompose. The results obtained were in harmony with previously reported tedious methods. The method is simple, rapid, quantitative and does not involve complex, hazardous or toxic chemistry.

  17. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    PubMed

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  18. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    PubMed

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  19. Development and validation of chromatographic methods (HPLC and GC) for the determination of the active components (benzocaine, tyrothricin and menthol) of a pharmaceutical preparation.

    PubMed

    Ortiz-Boyer, F; Tena, M T; Luque de Castro, M D; Valcárcel, M

    1995-10-01

    Methods are reported for the determination of tyrothricin and benzocaine by HPLC and menthol by GC in the analysis of throat lozenges (tablets) containing all three compounds. After optimization of the variables involved in both HPLC and GC the methods have been characterized and validated according to the guidelines of the Spanish Pharmacopoeia, and applied to both the monitoring of the manufacturing process and the quality control of the final product.

  20. High-performance liquid chromatographic characterization of some medical plant extracts used in cosmetic formulas.

    PubMed

    Schulz, H; Albroscheit, G

    1988-06-17

    Rapid and reliable methods are presented for the characterization of biologically active and/or characteristic constituents in aqueous extracts of Hamamelis virginiana, Matricaria chamomilla, Achillea millefolium, Thymus vulgaris, Althaea officinalis and Cinchonia spp. Prior to high-performance liquid chromatographic (HPLC) separation a clean-up step was performed using a solid-phase extraction system. The purified extracts were analysed by HPLC coupled with a diode-array detector and a fluorescence detector. In some instances, previously unreported components of the aqueous plant extracts were found.

  1. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  2. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  3. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  4. Semi-preparative HPLC preparation and HPTLC quantification of tetrahydroamentoflavone as marker in Semecarpus anacardium and its polyherbal formulations.

    PubMed

    Aravind, S G; Arimboor, Ranjith; Rangan, Meena; Madhavan, Soumya N; Arumughan, C

    2008-11-04

    Application of modern scientific knowledge coupled with sensitive analytical technique is important for the quality evaluation and standardization of polyherbal formulations. Semecarpus anacardium, an important medicinal plant with wide medicinal properties, is frequently used in a large number of traditional herbal preparations. Tetrahydroamentoflavone (THA), a major bioactive biflavonoid was selected as a chemical marker of S. anacardium and RP-semi-preparative HPLC conditions were optimized for the isolation of tetrahydroamentoflavone. HPTLC analytical method was developed for the fingerprinting of S. anacardium flavonoids and quantification of tetrahydroamentoflavone. The method was validated in terms of their linearity, LOD, LOQ, precision and accuracy and compared with RP-HPLC-DAD method. The methods were demonstrated for the chemical fingerprinting of S. anacardium plant parts and some commercial polyherbal formulations and the amount of tetrahydroamentoflavone was quantified. HPTLC analysis showed that S. anacardium seed contained approximately 10 g kg(-1) of tetrahydroamentoflavone. The methods were able to identify and quantify tetrahydroamentoflavone from complex mixtures of phytochemicals and could be extended to the marker-based standardization of polyherbal formulations, containing S. anacardium.

  5. A validated solid-liquid extraction method for the HPLC determination of polyphenols in apple tissues Comparison with pressurised liquid extraction.

    PubMed

    Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca

    2005-02-15

    A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.

  6. RP-HPLC Determination of Phenylalkanoids and Monoterpenoids in Rhodiola rosea and Identification by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    An HPLC method permitting the simultaneous determination of fourteen compounds (phenylalkanoids and monoterpenoids) from the roots of Rhodiola rosea was developed. A separation was achieved within 35 minutes by using C-18 column material, a water/acetonitrile mobile phase, both containing 0.05% phos...

  7. Counter-current chromatography with off-line detection by ultra high performance liquid chromatography/high resolution mass spectrometry in the study of the phenolic profile of Lippia origanoides.

    PubMed

    Leitão, Suzana Guimaraes; Leitão, Gilda Guimarães; Vicco, Douglas K T; Pereira, João Paulo Barreto; de Morais Simão, Gustavo; Oliveira, Danilo R; Celano, Rita; Campone, Luca; Piccinelli, Anna Lisa; Rastrelli, Luca

    2017-10-20

    Lippia origanoides (Verbenaceae) is an important Brazilian medicinal plant, also used for culinary purposes. Most chemical studies with this plant have been focused on its volatile composition. In this work, we combined High-Speed Counter-current Chromatography (HSCCC) and High Performance Liquid Chromatography coupled to Ultra Violet detection and High Resolution Mass Spectrometry (HPLC-UV-HRMS n ) methodologies to access the non-volatile chemical composition of L. origanoides. The crude ethanol extract of L. origanoides (LOEF) was first analyzed by HPLC-UV-HRMS n and allowed the identification of 7 major compounds. Among them, eriodictyol, naringenin and pinocembrin, were determined and are phytochemical markers of this plant. However, owing to the complexity of this plant matrix, LOEF was fractionated by HSCCC (hexane-ethanol-water, 4:3:1) as a tool for preparative pre-purification, affording a flavonoid-rich fraction. A column screening with the chromatographic stationary phases ZIC-HILIC, monolithic and particulate RP18 was performed. The best column separation was achieved with a Purospher STAR RP18e, which was used for HPLC-DAD-HRMS n studies. By this approach 12 compounds were further identified in addition to the major ones identified in the raw extract. Two of them, 6,8-di-C-hexosyl-luteolin and 6,8-di-C-glucosyl-apigenin, are being reported for the first time in the family Verbenaceae. This work shows the integration of HSCCC as a preparative tool for the fractionation and purification of natural products from a complex plant extract with other analytical techniques, with the purpose of showing each technique's potential. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. UHPLC-UV method for the determination of flavonoids in dietary supplements and for evaluation of their antioxidant activities.

    PubMed

    Magiera, Sylwia; Baranowska, Irena; Lautenszleger, Anna

    2015-01-01

    A simple and rapid ultra-high performance liquid chromatographic (UHPLC) method coupled with an ultraviolet detector (UV) has been developed and validated for the separation and determination of 14 major flavonoids ((±)-catechin, (-)-epicatechin, glycitin, (-)-epicatechin gallate, rutin, quercitrin, hesperidine, neohesperidine, daidzein, glycitein, quercetin, genistein, hesperetin, and biochanin A) in herbal dietary supplements. The flavonoids have been separated on a Chromolith Fast Gradient Monolithic RP-18e column utilizing a mobile phase composed of 0.05% trifluoroacetic acid in water and acetonitrile in gradient elution mode. Under these conditions, flavonoids were separated in a 5 min run. The selectivity of the developed UHPLC-UV method was confirmed by comparison with ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The validation parameters such as linearity, sensitivity, precision, and accuracy were found to be highly satisfactory. The optimized method was applied to determination of flavonoids in different dietary supplements. Additionally, the developed HPLC-UV method combined with 2,2-diphenyl-1-picrylhydrazyl radical (DPPH) assay was used in the evaluation of antioxidant activity of the selected flavonoids. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Simultaneous determination of phenolic acids and flavonoids in rice using solid-phase extraction and RP-HPLC with photodiode array detection.

    PubMed

    Irakli, Maria N; Samanidou, Victoria F; Biliaderis, Costas G; Papadoyannis, Ioannis N

    2012-07-01

    An analytical method based on an optimized solid-phase extraction procedure and followed by high-performance liquid chromatography (HPLC) separation with diode array detection was developed and validated for the simultaneous determination of phenolic acids (gallic, protocatechuic, 4-hydroxy-benzoic, vanillic, caffeic, syringic, p-coumaric, ferulic, sinapic, and cinnamic acids), flavanols (catechin and epicatechin), flavonols (myricetin, quercetin, kaempferol, quercetin-3-O-glucoside, hyperoside, and rutin), flavones (luteolin and apigenin) and flavanones (naringenin and hesperidin) in rice flour (Oryza sativa L.). Chromatographic separation was carried out on a PerfectSil Target ODS-3 (250 mm × 4.6 mm, 3 μm) column at temperature 25°C using a mobile phase, consisting of 0.5% (v/v) acetic acid in water, methanol, and acetonitrile at a flow rate 1 mL min(-1) , under gradient elution conditions. Application of optimum extraction conditions, elaborated on both Lichrolut C(18) and Oasis HLB cartridges, have led to extraction of phenolic acids and flavonoids from rice flour with mean recoveries 84.3-113.0%. The developed method was validated in terms of linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 5) and inter-day precision (n = 4) revealed relative standard deviation (RSD) <13%. The optimized method was successfully applied to the analysis of phenolic acids and flavonoids in pigmented (red and black rice) and non-pigmented rice (brown rice) samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    ERIC Educational Resources Information Center

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  11. Improving LC-MS sensitivity through increases in chromatographic performance: comparisons of UPLC-ES/MS/MS to HPLC-ES/MS/MS.

    PubMed

    Churchwell, Mona I; Twaddle, Nathan C; Meeker, Larry R; Doerge, Daniel R

    2005-10-25

    Recent technological advances have made available reverse phase chromatographic media with a 1.7 microm particle size along with a liquid handling system that can operate such columns at much higher pressures. This technology, termed ultra performance liquid chromatography (UPLC), offers significant theoretical advantages in resolution, speed, and sensitivity for analytical determinations, particularly when coupled with mass spectrometers capable of high-speed acquisitions. This paper explores the differences in LC-MS performance by conducting a side-by-side comparison of UPLC for several methods previously optimized for HPLC-based separation and quantification of multiple analytes with maximum throughput. In general, UPLC produced significant improvements in method sensitivity, speed, and resolution. Sensitivity increases with UPLC, which were found to be analyte-dependent, were as large as 10-fold and improvements in method speed were as large as 5-fold under conditions of comparable peak separations. Improvements in chromatographic resolution with UPLC were apparent from generally narrower peak widths and from a separation of diastereomers not possible using HPLC. Overall, the improvements in LC-MS method sensitivity, speed, and resolution provided by UPLC show that further advances can be made in analytical methodology to add significant value to hypothesis-driven research.

  12. Linear regression analysis and its application to multivariate chromatographic calibration for the quantitative analysis of two-component mixtures.

    PubMed

    Dinç, Erdal; Ozdemir, Abdil

    2005-01-01

    Multivariate chromatographic calibration technique was developed for the quantitative analysis of binary mixtures enalapril maleate (EA) and hydrochlorothiazide (HCT) in tablets in the presence of losartan potassium (LST). The mathematical algorithm of multivariate chromatographic calibration technique is based on the use of the linear regression equations constructed using relationship between concentration and peak area at the five-wavelength set. The algorithm of this mathematical calibration model having a simple mathematical content was briefly described. This approach is a powerful mathematical tool for an optimum chromatographic multivariate calibration and elimination of fluctuations coming from instrumental and experimental conditions. This multivariate chromatographic calibration contains reduction of multivariate linear regression functions to univariate data set. The validation of model was carried out by analyzing various synthetic binary mixtures and using the standard addition technique. Developed calibration technique was applied to the analysis of the real pharmaceutical tablets containing EA and HCT. The obtained results were compared with those obtained by classical HPLC method. It was observed that the proposed multivariate chromatographic calibration gives better results than classical HPLC.

  13. High-performance liquid chromatographic determination of pantoprazole and its main impurities in pharmaceuticals.

    PubMed

    Letica, Jelena; Marković, Slavko; Zirojević, Jelena; Nikolić, Katarina; Agbaba, Danica

    2010-01-01

    An RP-HPLC method for simultaneous separation and quantification of pantoprazole and its five main impurities in pharmaceutical formulations was developed and validated. The separation was accomplished on a Zorbax Eclipse XDB C18 column (5 microm particle size, 150 x 4.6 mm id) using a gradient with mobile phase A [buffer-acetonitrile (70 + 30, v/v)], and mobile phase B [buffer-acetonitrile (30 + 70, v/v)]. The buffer was 0.01 M ammonium acetate solution with addition of 1 mL triethylamine/L of the solution, adjusted to pH 4.5 with orthophosphoric acid. The eluent flow rate was 1 mL/min, the temperature of the column was 30 degrees C, and the eluate was monitored at 290 nm. Linearity (r = 0.999), recovery (97.6-105.8%), RSD (0.55-1.90%), and LOQ (0.099-1.48 microg/mL) were evaluated and found to be satisfactory. The proposed method can be used for simultaneous identification and quantification of the analyzed compounds in pharmaceutical formulations.

  14. High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms.

    PubMed

    Abd El-Hay, Soad S; Hashem, Hisham; Gouda, Ayman A

    2016-03-01

    A novel, simple and robust high-performance liquid chromatography (HPLC) method was developed and validated for simultaneous determination of xipamide (XIP), triamterene (TRI) and hydrochlorothiazide (HCT) in their bulk powders and dosage forms. Chromatographic separation was carried out in less than two minutes. The separation was performed on a RP C-18 stationary phase with an isocratic elution system consisting of 0.03 mol L(-1) orthophosphoric acid (pH 2.3) and acetonitrile (ACN) as the mobile phase in the ratio of 50:50, at 2.0 mL min(-1) flow rate at room temperature. Detection was performed at 220 nm. Validation was performed concerning system suitability, limits of detection and quantitation, accuracy, precision, linearity and robustness. Calibration curves were rectilinear over the range of 0.195-100 μg mL(-1) for all the drugs studied. Recovery values were 99.9, 99.6 and 99.0 % for XIP, TRI and HCT, respectively. The method was applied to simultaneous determination of the studied analytes in their pharmaceutical dosage forms.

  15. [Determination of obacunone and obaculactone in different processing products of Phellodendri amurensis cortex].

    PubMed

    Zhang, Chao

    2013-02-01

    To study the impact of different processing methods on the content of limonin compounds in Phellodendri Amurensis Cortex. Used RP-HPLC method to determine the content of obacunone and obaculactone in different processing products of Phellodendri Amurensis Cortex. The chromatographic separation was carried out on Kromasil C18 (250 mm x 4.6 mm,5 micro m), with mobile phase of acetonitrile and water (50: 50) at a flow rate of 1.0 mL/min. The column temperature was 25 degrees C and the detection wavelength was 205 nm. The content of obacunone and obaculactone had significant differences in different processing products. The sequence of the content changes of obacunone was as follows: raw products > fried carbon products > wine fried products salt fried products. The content of obaculactone was fried carbon products approximately wine fried products approximately salt fried products > raw products. The loss of obacunone in fried carbon products is much more than that of wine fried products or salt fried products. The content of obaculactone have similar degree of increase, increasing rate is 18.15%, 15.62% and 15.84%, respectively.

  16. Precolumn Derivatization with Bromine to Improve Separation and Detection Sensitivity of Triacylglycerols in Edible Oil by Reversed-Phase High Performance Liquid Chromatography.

    PubMed

    Shan, Xiao-Lin; Liu, Xiao-Ting; Gong, Can; Xu, Xu

    2018-01-01

    The complexity of triacylglycerols (TAGs) in edible oils is largely due to the many similar unsaturated TAG compounds, which makes profiling TAGs difficult. In this study, precolumn derivatization with bromine (Br 2 ) was used to improve the separation and detection sensitivity of TAGs in edible oils by RP-HPLC. Oil samples dissolved in n-hexane and TAGs were derived by reaction with a Br2-CCl 4 (1:1, v/v) solution for 3 h at room temperature. The derivate product solution was stable and was best separated and detected by RP-HPLC using a C18 column, with a mobile phase of methanol-n-hexane (91.5:8.5, v/v) at 25°C. A detection wavelength of 230 nm was used. The results showed that the approach enabled the separation and detection of more similar TAGs by RP-HPLC. The method was applied to profile 20 types of edible oil, and the results presented the differences in the TAG profiles of various edible oils, which may be useful in the identification of edible oils.

  17. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    PubMed

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  18. High performance liquid chromatographic hydrocarbon group-type analyses of mid-distillates employing fuel-derived fractions as standards

    NASA Technical Reports Server (NTRS)

    Seng, G. T.; Otterson, D. A.

    1983-01-01

    Two high performance liquid chromatographic (HPLC) methods have been developed for the determination of saturates, olefins and aromatics in petroleum and shale derived mid-distillate fuels. In one method the fuel to be analyzed is reacted with sulfuric acid, to remove a substantial portion of the aromatics, which provides a reacted fuel fraction for use in group type quantitation. The second involves the removal of a substantial portion of the saturates fraction from the HPLC system to permit the determination of olefin concentrations as low as 0.3 volume percent, and to improve the accuracy and precision of olefins determinations. Each method was evaluated using model compound mixtures and real fuel samples.

  19. High-performance liquid chromatographic method for the determination of moclobemide and its two major metabolites in human plasma.

    PubMed

    Rakic, Anita; Miljkovic, Branislava; Pokrajac, Milena; Vucicevic, Katarina

    2007-03-12

    A selective, sensitive, and simple high-performance liquid chromatographic (HPLC) method was developed for the determination of moclobemide and its two major metabolites, Ro 12-5637 and Ro 12-8095, in human plasma. Sample preparation (0.5 ml of plasma) involved solid-phase extraction (SPE) using Speedisk H(2)O-Philic DVB columns. Separations were performed on a Waters XTerra RP18 column (5 microm, 150 mm x 4.6 mm). The mobile phase consisted of 10 mM KH(2)PO(4) with 1% triethylamine (pH 3.9) and acetonitrile (83:17, v/v), and a flow-rate was 1.2 ml/min. The total run time was 13 min. UV detection was performed at 240 nm. Mean absolute recoveries were > or =90% and the limit of quantification (LOQ) for all analytes was 0.02 mg/l. Calibration curves were linear (r>0.995) over a wide range of the analyte concentrations in plasma; thus, the method is suitable for different clinical studies when large variations in the drug/metabolites concentrations are observed. During a 5-day assay validation procedure the accuracy and precision were tested and proven (relative errors (RE)< or =13%; intra-day coefficient of variation (CV)< or =7%; inter-day CV< or =13%). Many drugs frequently used in the target patient population were evaluated for potential interference in order method selectivity to be ensured. The assay has been used in a clinical pharmacokinetic study to assess steady-state pharmacokinetics of moclobemide and two metabolites in depressive patients on mono- and combined therapy.

  20. Simultaneous quantitative determination of six active components in traditional Chinese medicinal preparation Cerebralcare Granule® by RP-HPLC coupled with diode array detection for quality control.

    PubMed

    Wang, Xiang-yang; Ma, Xiao-hui; Li, Wei; Chu, Yang; Guo, Jia-hua; Zhou, Shui-ping; Zhu, Yong-hong

    2014-09-01

    A simple, accurate and reliable method for the simultaneous separation and determination of six active components (protocatechuic acid, chlorogenic acid, caffeic acid, paeoniflorin, ferulic acid and rosmarinic acid) in traditional Chinese medicinal preparation Cerebralcare Granule(®) (CG) was developed using reverse-phase high-performance liquid chromatography coupled with diode array detector detection. The chromatographic separation was performed on a Hypersil GOLD C18 column with aqueous formic acid (0.1%, v/v) and acetonitrile as mobile phase at a flow rate of 0.2 ml/min at 30 °C. Because of the different UV characteristics of these components, change detection wavelength method was used for quantitative analysis. All of the analytes showed good linearity (r > 0.9992). The established method showed good precision and relative standard deviations (%) for intra-day and inter-day variations of 0.15-1.81 and 0.11-1.98%, respectively. The validated method was successfully applied to the simultaneously determination of six active components in CG from different batches. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Determination of ambroxol hydrochloride, methylparaben and benzoic acid in pharmaceutical preparations based on sequential injection technique coupled with monolithic column.

    PubMed

    Satínský, Dalibor; Huclová, Jitka; Ferreira, Raquel L C; Montenegro, Maria Conceição B S M; Solich, Petr

    2006-02-13

    The porous monolithic columns show high performance at relatively low pressure. The coupling of short monoliths with sequential injection technique (SIA) results in a new approach to implementation of separation step to non-separation low-pressure method. In this contribution, a new separation method for simultaneous determination of ambroxol, methylparaben and benzoic acid was developed based on a novel reversed-phase sequential injection chromatography (SIC) technique with UV detection. A Chromolith SpeedROD RP-18e, 50-4.6 mm column with 10 mm precolumn and a FIAlab 3000 system with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-tetrahydrofuran-0.05M acetic acid (10:10:90, v/v/v), pH 3.75 adjusted with triethylamine, flow rate 0.48 mlmin(-1), UV-detection was at 245 nm. The analysis time was <11 min. A new SIC method was validated and compared with HPLC. The method was found to be useful for the routine analysis of the active compounds ambroxol and preservatives (methylparaben or benzoic acid) in various pharmaceutical syrups and drops.

  2. Comprehensive two-dimensional chromatography with coupling of reversed phase high performance liquid chromatography and supercritical fluid chromatography.

    PubMed

    Stevenson, Paul G; Tarafder, Abhijit; Guiochon, Georges

    2012-01-13

    A 2D comprehensive chromatographic separation of blackberry sage fragrant oil was performed by using HPLC in the first dimension and SFC in the second. A C(18)-bonded silica column eluted with an ACN gradient was used in the HPLC dimension and an amino-bonded silica column eluted with ACN as a modifier in the SFC dimension. This 2D separation was completed in the off-line mode, the fractions from the HPLC column being collected and injected in the SFC column. The retention factors on the two columns have a -0.757 correlation coefficient. The method provides a practical peak capacity of 2400 in 280 min. The first eluted peaks in HPLC are the last ones eluted in SFC and vice versa. The results demonstrate that the coupling of an HPLC and an SFC separation have a great potential for 2D chromatographic separations. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Two-Dimensional Offline Chromatographic Fractionation for the Characterization of Humic-Like Substances in Atmospheric Aerosol Particles.

    PubMed

    Spranger, Tobias; van Pinxteren, Dominik; Herrmann, Hartmut

    2017-05-02

    Organic carbon in atmospheric particles comprises a large fraction of chromatographically unresolved compounds, often referred to as humic-like substances (HULIS), which influence particle properties and impact climate, human health, and ecosystems. To better understand its composition, a two-dimensional (2D) offline method combining size-exclusion (SEC) and reversed-phase liquid chromatography (RP-HPLC) using a new spiked gradient profile is presented. It separates HULIS into 55 fractions of different size and polarity, with estimated ranges of molecular weight and octanol/water partitioning coefficient (log P) from 160-900 g/mol and 0.2-3.3, respectively. The distribution of HULIS within the 2D size versus polarity space is illustrated with heat maps of ultraviolet absorption at 254 nm. It is found to strongly differ in a small example set of samples from a background site near Leipzig, Germany. In winter, the most intense signals were obtained for the largest molecules (>520 g/mol) with low polarity (log P ∼ 1.9), whereas in summer, smaller (225-330 g/mol) and more polar (log P ∼ 0.55) molecules dominate. The method reveals such differences in HULIS composition in a more detailed manner than previously possible and can therefore help to better elucidate the sources of HULIS in different seasons or at different sites. Analyzing Suwannee river fulvic acid as a common HULIS surrogate shows a similar polarity range, but the sizes are clearly larger than those of atmospheric HULIS.

  4. Comparison of RP-HPLC modes to analyse the N-glycome of the free-living nematode Pristionchus pacificus

    PubMed Central

    Yan, Shi; Wilson, Iain B. H.; Paschinger, Katharina

    2015-01-01

    Pristionchus pacificus is a free-living nematode increasingly used as an organism for comparison to the more familiar model Caenorhabditis elegans. In this study, we examined the N-glycans of this organism isolated after serial release with peptide:N-glycosidases F and A; after fluorescent labelling with 2-aminopyridine, chromatographic fractionation by three types of reversed-phase HPLC (with either classical C18, fused core C18 or alkylamide bonded phases) followed by mass spectrometric analyses revealed key features of its N-glycome. In addition to paucimannosidic and oligomannosidic glycans typical of invertebrates, N-glycans with two core fucose residues were detected. Furthermore, a range of glycans carrying up to three phosphorylcholine residues was observed whereas, unlike C. elegans, no tetrafucosylated N-glycans were detected. Structures with three fucose residues, unusual methylation of core α1,3-fucose or with galactosylated fucose motifs were found in low amounts; these features may correlate with a different ensemble or expression of glycosyltransferase genes as compared to C. elegans. From an analytical perspective, both the alkylamide RP-amide and fused core C18 columns, as compared to a classical C18 material, offer advantages in terms of resolution and of elution properties, as some minor pyridylamino-labelled glycans (e.g., those carrying phosphorylcholine) appear in earlier fractions and so potential losses of such structures due to insufficient gradient length can be avoided. PMID:25639343

  5. Novel Chromatographic Methods for Simultaneous Quantification of Fish and Wheat Germ Oils Mixture in Pharmaceutical Dosage Forms.

    PubMed

    El-Yazbi, Amira F; El-Hawiet, Amr

    2017-05-01

    Two simple, direct and environment-friendly chromatographic methods, high-performance liquid chromatography (HPLC) and high-performance thin layer chromatographic (HPTLC), were developed for the determination of a binary mixture of fish oil (FO) and wheat germ oil (WGO), for the first time, in their pharmaceutical dosage forms with no need for any sample pretreatment. The HPLC separation was carried out using C-18 stationary phase with mobile phase of 15% formic acid (pH 6), methanol and acetonitrile through gradient-elution, 1.5 mL min-1 flow-rate and detection at 215 nm for FO and 280 nm for WGO. HPTLC separation was carried out on silica-coated plates using diethyl ether-petroleum ether (0.5:9.5, v/v) as mobile phase. Detection was at 215 nm for FO and 240 nm for WGO. Regression analysis showed good linear relationship with r > 0.999 in the concentration-ranges of 0.2-2 mg mL-1 and 2.5-20 μg band-1 for WGO by HPLC and HPTLC methods, respectively, and 0.4-10 mg mL-1 and 25-200 μg band-1 for FO by HPLC and HPTLC methods, respectively. The methods were validated, showed good analytical performance and were successfully applied for the analysis of pharmaceutical formulations and synthetic mixtures of the analytes with good recoveries. Therefore, the two methods could be conveniently adopted for routine analysis of similar products in quality control laboratories of pharmaceutical industries especially that simultaneous determination of FO-WGO mixture has not been reported previously. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Simple and simultaneous determination of the hiv-protease inhibitors amprenavir, atazanavir, indinavir, lopinavir, nelfinavir, ritonavir and saquinavir plus M8 nelfinavir metabolite and the nonnucleoside reverse transcriptase inhibitors efavirenz and nevirapine in human plasma by reversed-phase liquid chromatography.

    PubMed

    Poirier, Jean-Marie; Robidou, Pascal; Jaillon, Patrice

    2005-04-01

    Several studies suggest that therapeutic drug monitoring of protease inhibitors and nonnucleoside reverse transcriptase inhibitors may contribute to the clinical outcome of HIV-infected patients. Because of the growing number of antiretroviral drugs and of drug combinations than can be administered to these patients, an accurate high-performance liquid chromatographic (HPLC) method allowing the simultaneous determination of these drugs may be useful. To date, the authors present the first simultaneous HPLC determination of the new protease inhibitor atazanavir with all the others currently in use (M8 nelfinavir metabolite included) and the 2 widely used nonnucleoside reverse transcriptase inhibitors efavirenz and nevirapine. This simple HPLC method allows the analysis all these drugs at a single ultraviolet wavelength following a 1-step liquid-liquid extraction procedure. A 500-muL plasma sample was spiked with internal standard and subjected to liquid-liquid extraction using by diethyl ether at pH 10. HPLC was performed using a Symmetry Shield RP18 and gradient elution. All the drugs of interest and internal standard were detected with ultraviolet detection at 210 nm. Calibration curves were linear in the range 50-10,000 ng/mL. The observed concentrations of the quality controls at plasma concentrations ranging from 50 to 5000 ng/mL for these drugs showed that the overall accuracy varied from 92% to 104% and 92% to 106% for intraday and day-to-day analysis, respectively. No metabolites of the assayed compounds or other drugs commonly coadministered to HIV-positive patients were found to coelute with the drugs of interest or with the internal standard. This assay was developed for the purpose of therapeutic monitoring (TDM) in HIV-infected patients.

  7. Stability indicating RP-HPLC method development and validation for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form.

    PubMed

    Siddiraju, S; Sahithi, M

    2015-03-01

    The objective of the present work is to develop stability indicating high-performance liquid chromatographic method for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form. The chromatographic separation was achieved with BDS Hypersil C18 column (250 mm×4.6 mm×5 μ) as stationary phase and phosphate buffer and acetonitrile (78:22) as mobile phase. The method was employed by using a flow rate of 1.1 mL/min kept at 30°C. The detection wavelength was kept at 238 nm by using photo-diode array detector. The retention times of the aminexil and minoxidil were found to be 2.3 min and 3.9 min, respectively. The method developed was validated in accordance with ICH guidelines with respect to the stability indicating capacity of the method including system suitability, accuracy, precision, linearity, range, limit of detection, limit of quantification and robustness. The linearity responses of aminexil and minoxidil were found to be in the concentration ranges of 18.75-112.5 μg/mL and 25-150 μg/mL, respectively. The LOD and LOQ values for aminexil were found to be 0.31 and 0.92 μg/mL and minoxidil were found to be 0.03 and 0.10 μg/mL respectively. The percentage recoveries for both the drugs were found in the range of 98-101%. This method is accurate, precise and sensitive; hence, it can be employed for routine quality control of aminexil and minoxidil in pharmaceutical industries and drug testing laboratories. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. [Determination of genkwanin in flos Genkwa by HPLC].

    PubMed

    Zhang, B; Yuan, S; Xia, K

    1996-04-01

    In this paper, the method for determining genkwanin in Flos Genkwa was established by HPLC. Detected at 332nm on a Lichrosorb 5 RP-18 column with a mobile phase of methanol-water-acetic acid (65:35:5), the content of genkwanin in Flos Genkwa was determined to be 0.16%. The recovery rate was 95.46% and RSD 1.15%.

  9. Exploratory characterization of the unsaponifiable fraction of tunisian virgin olive oils by a global approach with HPLC-APCI-IT MS/MS analysis.

    PubMed

    Zarrouk, Wissem; Carrasco-Pancorbo, Alegría; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto; Zarrouk, Mokhtar

    2010-05-26

    The unsaponifiable fraction of six Tunisian monovarietal virgin olive oils from the region of Medenine was evaluated within a single chromatographic run by using HPLC-APCI-tandem MS. Separation of the compounds under study was achieved by the RP-LC method, giving a reasonable analysis time and good resolution. Detection was done by an ion trap (working alternatively in MS and MS/MS modes), the fact which made our method suitable to unequivocally identify a high number of compounds belonging to different families of the unsaponifiable fraction of oil and to carry out their reliable and sensitive quantification. A great amount of qualitative information was generated in every analysis, although we focused on the quantification of sterols, tocopherols, and triterpenic dialcohols since their standards were commercially available. The limits of detections achieved were within the range of 1.21 and 10.31 microg/kg for sitostanol and beta-sitosterol, respectively. Significant differences were observed in the composition of the studied olive cultivars. Jemri Ben Guerdane oil was the richest one in terms of all of the sterols under study. alpha-Tocopherol was the main vitamin E isomer in all samples, ranging from 70.14 to 130.72 mg/kg. Principal component analysis (PCA) and cluster analysis were applied to the whole data set in order to explore the distribution of the olive cultivars according to their oil composition.

  10. Spectroscopic characterization and quantitative determination of atorvastatin calcium impurities by novel HPLC method

    NASA Astrophysics Data System (ADS)

    Gupta, Lokesh Kumar

    2012-11-01

    Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.

  11. Multiresidue chromatographic method for the determination of macrolide residues in muscle by high-performance liquid chromatography with UV detection.

    PubMed

    Juhel-Gaugain, M; Anger, B; Laurentie, M

    1999-01-01

    A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of tilmicosin, tylosin, spiramycin, and its major metabolite neospiramycin was developed that is suitable for porcine, bovine, and poultry muscles. Macrolide residues were extracted from muscle with acetonitrile, fat was removed by liquid-liquid extraction with isooctane, and the extract was then cleaned on Bond Elut C18 cartridges. The HPLC separation was performed on an Inertsil ODS3 C18 column (150 x 4 mm) with 0.05% trifluoroacetic acid-acetonitrile in a gradient mode. Two different chromatographic gradients were used for tilmicosin-tylosin and spiramycin-neospiramycin, and the detection wavelengths were 287 and 232 nm, respectively. The method was validated from 1/2 the maximum residue limit (MRL) to 4 times the MRL with pork muscle samples. Mean recoveries were 60, 63.5, 51, and 42% for tilmicosin, tylosin, spiramycin, and neospiramycin, respectively. The detection limits are 15 micrograms/kg for tilmicosin and tylosin, 30 micrograms/kg for spiramycin, and 25 micrograms/kg for neospiramycin. Linearity, precision, and accuracy of the method were also tested.

  12. Angiotensin-converting enzyme (ACE) inhibitory potential of standardized Mucuna pruriens seed extract.

    PubMed

    Chaudhary, Sushil Kumar; De, Apurba; Bhadra, Santanu; Mukherjee, Pulok K

    2015-01-01

    Mucuna pruriens Linn. (Fabaceae) is a tropical legume, traditionally used for controlling blood pressure. Inhibition of angiotensin-converting enzyme (ACE) is one of the successful strategies for controlling hypertension. The present study evaluated the ACE inhibition potential of the standardized extract of M. pruriens seeds. Standardization of the extract and its fractions were carried out by RP-HPLC method [methanol and 1% v/v acetic acid in water (5:95 v/v)] using levodopa as a marker. The ACE inhibition activity of the extract and fractions was evaluated at different concentrations (20, 40, 60, 80, and 100 µg/mL) using the HPLC-DAD and the UV spectrophotometric method. The liberation of hippuric acid (HA) from hippuryl-L-histidyl-L-leucine (HHL) was estimated in the spectrophotometric method and RP-HPLC assay at 228 nm. Methanol extract and aqueous fraction showed a maximum activity with IC50 values of 38.44 ± 0.90 and 57.07 ± 2.90 µg/mL (RP-HPLC), and 52.68 ± 2.02 and 67.65 ± 2.40 µg/mL (spectrophotometry), respectively. The study revealed that the aqueous extract contains the highest amount of levodopa. Eventually the methanol extract showed highest ACE inhibition activity except levodopa alone. It was further observed that the inhibition was altered with respect to the change in the content of levodopa in the extract. Thus, it can be assumed that levodopa may be responsible for the ACE inhibition activity of M. pruriens seeds. It can be concluded that M. pruriens seed is a potential ACE inhibitor can be explored further as an effective antihypertensive agent.

  13. [Determination of content and entrapment efficiency of 20 (S)-protopanaxadiol in pharmacosomes by RP-HPLC method].

    PubMed

    Han, Meihua; Chen, Jing; Chen, Shilin; Wang, Xiangtao

    2009-05-01

    To establish a RP-HPLC method for content and entrapment efficiency of 20 (S)-protopanaxadiol in pharmacosomes. The separation was performed with a COSMOSIL 5 C18-MS-II column (4.6 mm x 250 mm, 5 mmicrom) using methanol-water (95:5) as the mobile phase and detected at 203 nm. The flow rate was 1.0 mL x min(-1) and 50 microL sample solution was injected for each time. The calibration curve was linear within the range 0.1-0.5 mg x mL(-1) (r = 0. 9999) , the intra-day RSD and inter-day RSD were less than 2% and the average recovery was between 101.44%-103.11% (n = 3). The method is simple, accurate, sensitive and applicable for determination of content and entrapment efficiency of 20 (S)-protopanaxadiol pharmacosomes.

  14. Investigation of Soman Adducts of Human Hemoglobin by Liquid Chromatography

    DTIC Science & Technology

    2004-04-01

    acid standard, with fifteen primary amino acids , was used to evaluate and refine the chromatographic methods . An LC/MS/MS was used to analyze the non...several chromatographic conditions and stationary phases were used to create an LC/MS/MS method to directly analyze the amino acids , these studies...terminated because of a lack of resolution of the amino acid peaks. Also, initial attempts to develop an HPLC method to separate individual amino acids

  15. Assessment of repeatability of composition of perfumed waters by high-performance liquid chromatography combined with numerical data analysis based on cluster analysis (HPLC UV/VIS - CA).

    PubMed

    Ruzik, L; Obarski, N; Papierz, A; Mojski, M

    2015-06-01

    High-performance liquid chromatography (HPLC) with UV/VIS spectrophotometric detection combined with the chemometric method of cluster analysis (CA) was used for the assessment of repeatability of composition of nine types of perfumed waters. In addition, the chromatographic method of separating components of the perfume waters under analysis was subjected to an optimization procedure. The chromatograms thus obtained were used as sources of data for the chemometric method of cluster analysis (CA). The result was a classification of a set comprising 39 perfumed water samples with a similar composition at a specified level of probability (level of agglomeration). A comparison of the classification with the manufacturer's declarations reveals a good degree of consistency and demonstrates similarity between samples in different classes. A combination of the chromatographic method with cluster analysis (HPLC UV/VIS - CA) makes it possible to quickly assess the repeatability of composition of perfumed waters at selected levels of probability. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  16. Novel and sensitive reversed-phase high-pressure liquid chromatography method with electrochemical detection for the simultaneous and fast determination of eight biogenic amines and metabolites in human brain tissue.

    PubMed

    Van Dam, Debby; Vermeiren, Yannick; Aerts, Tony; De Deyn, Peter Paul

    2014-08-01

    A fast and simple RP-HPLC method with electrochemical detection (ECD) and ion pair chromatography was developed, optimized and validated in order to simultaneously determine eight different biogenic amines and metabolites in post-mortem human brain tissue in a single-run analytical approach. The compounds of interest are the indolamine serotonin (5-hydroxytryptamine, 5-HT), the catecholamines dopamine (DA) and (nor)epinephrine ((N)E), as well as their respective metabolites, i.e. 3,4-dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA), 5-hydroxy-3-indoleacetic acid (5-HIAA) and 3-methoxy-4-hydroxyphenylglycol (MHPG). A two-level fractional factorial experimental design was applied to study the effect of five experimental factors (i.e. the ion-pair counter concentration, the level of organic modifier, the pH of the mobile phase, the temperature of the column, and the voltage setting of the detector) on the chromatographic behaviour. The cross effect between the five quantitative factors and the capacity and separation factors of the analytes were then analysed using a Standard Least Squares model. The optimized method was fully validated according to the requirements of SFSTP (Société Française des Sciences et Techniques Pharmaceutiques). Our human brain tissue sample preparation procedure is straightforward and relatively short, which allows samples to be loaded onto the HPLC system within approximately 4h. Additionally, a high sample throughput was achieved after optimization due to a total runtime of maximally 40min per sample. The conditions and settings of the HPLC system were found to be accurate with high intra and inter-assay repeatability, recovery and accuracy rates. The robust analytical method results in very low detection limits and good separation for all of the eight biogenic amines and metabolites in this complex mixture of biological analytes. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Selective enrichment and desalting of hydrophilic peptides using graphene oxide.

    PubMed

    Jiang, Miao; Qi, Linyu; Liu, Peiru; Wang, Zijun; Duan, Zhigui; Wang, Ying; Liu, Zhonghua; Chen, Ping

    2016-08-01

    The wide variety and low abundance of peptides in tissue brought great difficulties to the separation and identification of peptides, which is not in favor of the development of peptidomics. RP-HPLC, which could purify small molecules based on their hydrophobicity, has been widely used in the separation and enrichment of peptide due to its fast, good reproducibility and high resolution. However, RP-HPLC requires the instrument and expensive C18 column and its sample capacity is also limited. Recently, graphene oxide has been applied to the adsorption of amino acids. However, the enrichment efficiency and selectivity of graphene oxide for peptides remain unclear. In this study, the adsorption efficiency and selectivity of graphene oxide and RP-C18 matrix were compared on trypsinized α-actin and also on tissue extracts from pituitary gland and hippocampus. For α-actin, there exhibit similar elution peaks for total trypsinized products and those adsorpted by GO and C18 matrix. But peptides adsorbed by GO showed the higher hydrophilic peaks than which adsorbed by C18 matrix. The resulted RP-HPLC profile showed that most of peptides enriched by graphene oxide were eluted at low concentration of organic solvent, while peptides adsorbed by RP-C18 matrix were mostly eluted at relatively high concentration. Moreover, mass spectrometry analysis suggested that, in pituitary sample, there were 495 peptides enriched by graphene oxide, 447 peptides enriched by RP-C18 matrix while in hippocampus sample 333 and 243 peptides respectively. The GRAVY value analysis suggested that the graphene oxide has a stronger adsorption for highly hydrophilic peptides compared to the RP-C18 matrix. Furthermore, the combination of these two methods could notably increase the number of identification peptides but also the number of predicted protein precursors. Our study provided a new thought to the role of graphene oxide during the enrichment of peptides from tissue which should be useful for peptidomics study. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Simple, fast and reliable liquid chromatographic and spectrophotometric methods for the determination of theophylline in urine, saliva and plasma samples.

    PubMed

    Charehsaz, Mohammad; Gürbay, Aylin; Aydin, Ahmet; Sahin, Gönül

    2014-01-01

    In this study, a high-performance liquid chromatographic method (HPLC) and UV spectrophotometric method were developed, validated and applied for the determination of theophylline in biological fluids. Liquid- liquid extraction is performed for isolation of the drug and elimination of plasma and saliva interferences. Urine samples were applied without any extraction. The chromatographic separation was achieved on a C18 column by using 60:40 methanol:water as mobile phase under isocratic conditions at a flow rate of 0.75 mL/min with UV detection at 280 nm in HPLC method. UV spectrophotometric analysis was performed at 275 nm. the limit of quantification: 1.1 µg/mL for urine, 1.9 µg/mL for saliva, 3.1 µg/mL for plasma; recovery: 94.85% for plasma, 100.45% for saliva, 101.39% for urine; intra-day precision: 0.22-2.33%, inter-day precision: 3.17-13.12%. Spectrophotometric analysis results were as follows: the limit of quantitation: 5.23 µg/mL for plasma, 8.7 µg/mL for urine; recovery: 98.27% for plasma, 95.25% for urine; intra-day precision: 2.37 - 3.00%, inter-day precision: 5.43-7.91%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for determination of theophylline in biological samples. Also spectrophotometric analysis can be used where it can be applicable.

  19. Comparison of the phenolic composition of fruit juices by single step gradient HPLC analysis of multiple components versus multiple chromatographic runs optimised for individual families.

    PubMed

    Bremner, P D; Blacklock, C J; Paganga, G; Mullen, W; Rice-Evans, C A; Crozier, A

    2000-06-01

    After minimal sample preparation, two different HPLC methodologies, one based on a single gradient reversed-phase HPLC step, the other on multiple HPLC runs each optimised for specific components, were used to investigate the composition of flavonoids and phenolic acids in apple and tomato juices. The principal components in apple juice were identified as chlorogenic acid, phloridzin, caffeic acid and p-coumaric acid. Tomato juice was found to contain chlorogenic acid, caffeic acid, p-coumaric acid, naringenin and rutin. The quantitative estimates of the levels of these compounds, obtained with the two HPLC procedures, were very similar, demonstrating that either method can be used to analyse accurately the phenolic components of apple and tomato juices. Chlorogenic acid in tomato juice was the only component not fully resolved in the single run study and the multiple run analysis prior to enzyme treatment. The single run system of analysis is recommended for the initial investigation of plant phenolics and the multiple run approach for analyses where chromatographic resolution requires improvement.

  20. Simultaneous determination of related substances of telmisartan and hydrochlorothiazide in tablet dosage form by using reversed phase high performance liquid chromatographic method

    PubMed Central

    Mukhopadhyay, Sutirtho; Kadam, Kiran; Sawant, Laxman; Nachane, Dhanashree; Pandita, Nancy

    2011-01-01

    Objective: Telmisartan is a potent, long-lasting, nonpeptide antagonist of the angiotensin II type-1 (AT1) receptor that is indicated for the treatment of essential hypertension. Hydrochlorothiazide is a widely prescribed diuretic and it is indicated for the treatment of edema, control of essential hypertension and management of diabetes insipidus. In the current article a new, accurate, sensitive, precise, rapid, reversed phase high performance liquid chromatography (RP-HPLC) method was developed for determination of related substances of Telmisartan and Hydrochlorthiazide in tablet dosage form. Materials and Methods: Simultaneous determination of related substances was performed on Kromasil C18 analytical column (250 × 4.6 mm; 5μm pertical size) column at 40°C employing a gradient elution. Mobile phase consisting of solvent A (solution containing 2.0 g of potassium dihydrogen phosphate anhydrous and 1.04 g of Sodium 1- Hexane sulphonic acid monohydrate per liter of water, adjusted to pH 3.0 with orthophosphoric acid) and solvent B (mixture of Acetonitrile: Methanol in the ratio 80:20 v/v) was used at a flow rate of 1.0 ml min–1. UV detection was performed at 270 nm. Results: During method validation parameter such as precision, linearity, accuracy, specificity, limit of detection and quantification were evaluated, which remained within acceptable limits. Conclusions: HPLC analytical method is linear, accurate, precise, robust and specific, being able to separate the main drug from its degradation products. It may find application for the routine analysis of the related substances of both Telmisartan and Hydrochlorthiazide in this combination tablets. PMID:21966158

  1. Authentication and Quantitation of Fraud in Extra Virgin Olive Oils Based on HPLC-UV Fingerprinting and Multivariate Calibration

    PubMed Central

    Carranco, Núria; Farrés-Cebrián, Mireia; Saurina, Javier

    2018-01-01

    High performance liquid chromatography method with ultra-violet detection (HPLC-UV) fingerprinting was applied for the analysis and characterization of olive oils, and was performed using a Zorbax Eclipse XDB-C8 reversed-phase column under gradient elution, employing 0.1% formic acid aqueous solution and methanol as mobile phase. More than 130 edible oils, including monovarietal extra-virgin olive oils (EVOOs) and other vegetable oils, were analyzed. Principal component analysis results showed a noticeable discrimination between olive oils and other vegetable oils using raw HPLC-UV chromatographic profiles as data descriptors. However, selected HPLC-UV chromatographic time-window segments were necessary to achieve discrimination among monovarietal EVOOs. Partial least square (PLS) regression was employed to tackle olive oil authentication of Arbequina EVOO adulterated with Picual EVOO, a refined olive oil, and sunflower oil. Highly satisfactory results were obtained after PLS analysis, with overall errors in the quantitation of adulteration in the Arbequina EVOO (minimum 2.5% adulterant) below 2.9%. PMID:29561820

  2. Comparison of UV spectrophotometry and high performance liquid chromatography methods for the determination of repaglinide in tablets

    PubMed Central

    Dhole, Seema M.; Khedekar, Pramod B.; Amnerkar, Nikhil D.

    2012-01-01

    Background: Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. Objective: UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. Materials and Methods: The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. Results: The developed methods illustrated excellent linearity (r2 > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. Conclusion: The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations. PMID:23781481

  3. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    PubMed

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Separation of flavonol-2-O-glycosides from Calendula officinalis and Sambucus nigra by high-performance liquid and micellar electrokinetic capillary chromatography.

    PubMed

    Pietta, P; Bruno, A; Mauri, P; Rava, A

    1992-02-28

    Calendula officinalis and Sambucus nigra flowers were analysed by reversed-phase high-performance liquid chromatography (RP-HPLC) and micellar electrokinetic capillary chromatography (MECC). RP-HPLC was performed on C8 Aquapore RP 300 columns with eluents containing 2-propanol and tetrahydrofuran. MECC was carried out on a 72-cm fused-silica capillary using sodium dodecyl sulphate and sodium borate (pH 8.3) as the running buffer. The results obtained by these techniques are compared.

  5. Comparison of UV spectrophotometry and high performance liquid chromatography methods for the determination of repaglinide in tablets.

    PubMed

    Dhole, Seema M; Khedekar, Pramod B; Amnerkar, Nikhil D

    2012-07-01

    Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. The developed methods illustrated excellent linearity (r(2) > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations.

  6. Detection of monohydroxylated polycyclic aromatic hydrocarbons in urine and particulate matter using LC separations coupled with integrated SPE and fluorescence detection or coupled with high-resolution time-of-flight mass spectrometry.

    PubMed

    Lintelmann, Jutta; Wu, Xiao; Kuhn, Evelyn; Ritter, Sebastian; Schmidt, Claudia; Zimmermann, Ralf

    2018-05-01

    A high-performance liquid chromatographic (HPLC) method with integrated solid-phase extraction for the determination of 1-hydroxypyrene and 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid-phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core-shell column using a methanol gradient. For quantification, time-programmed fluorescence detection was used. Matrix-dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC-fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra-high-performance liquid chromatography pentafluorophenyl core-shell column and coupled to a high-resolution time-of-flight mass spectrometer (HR-TOF-MS). The resulting method was used to demonstrate the applicability of LC-HR-TOF-MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter. Copyright © 2018 John Wiley & Sons, Ltd.

  7. Simultaneous Speciation of Arsenic, Selenium, and Chromium by HPLC-ICP-MS

    USGS Publications Warehouse

    Wolf, Ruth E.; Morman, Suzette A.; Morrison, Jean M.; Lamothe, Paul J.

    2008-01-01

    An adaptation of an analytical method developed for chromium speciation has been utilized for the simultaneous determination of As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI) species using high performance liquid chromatography (HPLC) separation with ICP-MS detection. Reduction of interferences for the determination of As, Se, and Cr by ICP-MS is a major consideration for this method. Toward this end, a Dynamic Reaction Cell (DRC) ICP-MS system was used to detect the species eluted from the chromatographic column. A variety of reaction cell gases and conditions may be utilized, and the advantages and limitations of the gases tested to date will be presented and discussed. The separation and detection of the As, Se, and Cr species of interest can be achieved using the same chromatographic conditions in less than 2 minutes by complexing the Cr(III) with EDTA prior to injection on the HPLC column. Practical aspects of simultaneous speciation analysis will be presented and discussed, including issues with HPLC sample vial contamination, standard and sample contamination, species stability, and considerations regarding sample collection and preservation methods. The results of testing to determine the method's robustness to common concomitant element and anion effects will also be discussed. Finally, results will be presented using the method for the analysis of a variety of environmental and geological samples including waters, soil leachates and simulated bio-fluid leachates.

  8. Pharmacokinetic study of arctigenin in rat plasma and organ tissue by RP-HPLC method.

    PubMed

    He, Fan; Dou, De-Qiang; Hou, Qiang; Sun, Yu; Kang, Ting-Guo

    2013-01-01

    A high-performance liquid chromatography (HPLC) technique was developed for the determination of arctigenin in plasma and various organs of rats after the oral administration of 30, 50 and 70 mgkg(-1) of arctigenin to the Sprague-Dawley rats. Results showed that the validated HPLC method was simple, fast, reproducible and suitable to the determination of arctigenin in rat plasma and organ tissue and one-compartmental model with zero-order absorption process can well describe the changes of arctigenin concentration in the plasma. The concentration of compound was highest in the spleen, less in the liver and the least in the lung.

  9. Standardization of RP-HPLC methods for the detection of the major peanut allergens Ara h 1, Ara h 2 and Ara h 3

    USDA-ARS?s Scientific Manuscript database

    Crude peanut extract (CPE) was analyzed for three major allergens (Ara h 1, h 2, and h 3) using a C12 and a C18 column at two wavelengths (280 and 220 nm) and under different solvent conditions. HPLC profiles were compared for retention time, resolution, and peak heights. CPE samples were spiked wit...

  10. Analysis of Organic Acids, Deacetyl Asperulosidic Acid and Polyphenolic Compounds as a Potential Tool for Characterization of Noni (Morinda citrifolia) Products.

    PubMed

    Bittová, Miroslava; Hladůkova, Dita; Roblová, Vendula; Krácmar, Stanislav; Kubán, Petr; Kubán, Vlastimil

    2015-11-01

    Organic acids, deacetyl asperulosidic acid (DAA) and polyphenolic compounds in various noni (Morinda citrifolia L.) products (4 juices, 4 dry fruit powders and 2 capsules with dry fruit powder) were analyzed. Reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a variable wavelength detector (VWD) and electrospray ionization time-of-flight mass spectrometer (ESI-TOF MS) was applied for simultaneous analysis of organic acids (malic, lactic, citric and succinic acid) and DAA. An RP-HPLC method with diode-array detector (DAD) was developed for the analysis of polyphenolic compound content (rutin, catechin, quercitrin, kaempferol, gallic acid, caffeic acid and p-coumaric acid). The developed methods can contribute to better characterization of available noni products that is required from the consumers. In our study, we discovered significant dissimilarities in the content of DAA, citric acid and several phenolic compounds in some samples.

  11. QUANTIFICATION OF GLYCYRRHIZIN BIOMARKER IN GLYCYRRHIZA GLABRA RHIZOME AND BABY HERBAL FORMULATIONS BY VALIDATED RP-HPTLC METHODS

    PubMed Central

    Alam, Prawez; Foudah, Ahmed I.; Zaatout, Hala H.; T, Kamal Y; Abdel-Kader, Maged S.

    2017-01-01

    Background: A simple and sensitive thin-layer chromatographic method has been established for quantification of glycyrrhizin in Glycyrrhiza glabra rhizome and baby herbal formulations by validated Reverse Phase HPTLC method. Materials and Methods: RP-HPTLC Method was carried out using glass coated with RP-18 silica gel 60 F254S HPTLC plates using methanol-water (7: 3 v/v) as mobile phase. Results: The developed plate was scanned and quantified densitometrically at 256 nm. Glycyrrhizin peaks from Glycyrrhiza glabra rhizome and baby herbal formulations were identified by comparing their single spot at Rf = 0.63 ± 0.01. Linear regression analysis revealed a good linear relationship between peak area and amount of glycyrrhizin in the range of 2000-7000 ng/band. Conclusion: The method was validated, in accordance with ICH guidelines for precision, accuracy, and robustness. The proposed method will be useful to enumerate the therapeutic dose of glycyrrhizin in herbal formulations as well as in bulk drug. PMID:28573236

  12. Two novel solvent system compositions for protected synthetic peptide purification by centrifugal partition chromatography.

    PubMed

    Amarouche, Nassima; Giraud, Matthieu; Forni, Luciano; Butte, Alessandro; Edwards, F; Borie, Nicolas; Renault, Jean-Hugues

    2014-04-11

    Protected synthetic peptide intermediates are often hydrophobic and not soluble in most common solvents. They are thus difficult to purify by preparative reversed-phase high-performance liquid chromatography (RP-HPLC), usually used for industrial production. It is then challenging to develop alternative chromatographic purification processes. Support-free liquid-liquid chromatographic techniques, including both hydrostatic (centrifugal partition chromatography or CPC) and hydrodynamic (counter-current chromatography or CCC) devices, are mainly involved in phytochemical studies but have also been applied to synthetic peptide purification. In this framework, two new biphasic solvent system compositions covering a wide range of polarity were developed to overcome solubility problems mentioned above. The new systems composed of heptane/tetrahydrofuran/acetonitrile/dimethylsulfoxide/water and heptane/methyl-tetrahydrofuran/N-methylpyrrolidone/water were efficiently used for the CPC purification of a 39-mer protected exenatide (Byetta®) and a 8-mer protected peptide intermediate of bivalirudin (Angiox®) synthesis. Phase compositions of the different biphasic solvent systems were determined by (1)H nuclear magnetic resonance. Physico-chemical properties including viscosity, density and interfacial tension of these biphasic systems are also described. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Ultrasound extracted flavonoids from four varieties of Portuguese red grape skins determined by reverse-phase high-performance liquid chromatography with electrochemical detection.

    PubMed

    Novak, Ivana; Janeiro, Patricia; Seruga, Marijan; Oliveira-Brett, Ana Maria

    2008-12-23

    Several flavonoids present in red grape skins from four varieties of Portuguese grapes were determined by reverse-phase high-performance liquid chromatography (RP-HPLC) with electrochemical detection (ECD). Extraction of flavonoids from red grape skins was performed by ultrasonication, and hydrochloric acid in methanol was used as extraction solvent. The developed RP-HPLC method used combined isocratic and gradient elution with amperometric detection with a glassy carbon-working electrode. Good peak resolution was obtained following direct injection of a sample of red grape extract in a pH 2.20 mobile phase. Eleven different flavonoids: cyanidin-3-O-glucoside (kuromanin), delphinidin-3-O-glucoside (myrtillin), petunidin-3-O-glucoside, peonidin-3-O-glucoside, malvidin-3-O-glucoside (oenin), (+)-catechin, rutin, fisetin, myricetin, morin and quercetin, can be separated in a single run by direct injection of sample solution. The limit of detection obtained for these compounds by ECD was 20-90 pg/L, 1000 times lower when compared with photodiode array (PDA) limit of detection of 12-55 ng/L. RP-HPLC-ECD was characterized by an excellent sensitivity and selectivity, and appropriate for the simultaneous determination of these electroactive phenolic compounds present in red grape skins.

  14. Fractionation and proteomic analysis of the Walterinnesia aegyptia snake venom using OFFGEL and MALDI-TOF-MS techniques.

    PubMed

    Abd El Aziz, Tarek Mohamed; Bourgoin-Voillard, Sandrine; Combemale, Stéphanie; Beroud, Rémy; Fadl, Mahmoud; Seve, Michel; De Waard, Michel

    2015-10-01

    Animal venoms are complex mixtures of more than 100 different compounds, including peptides, proteins, and nonprotein compounds such as lipids, carbohydrates, and metal ions. In addition, the existing compounds show a wide range of molecular weights and concentrations within these venoms, making separation and purification procedures quite tedious. Here, we analyzed for the first time by MS the advantages of using the OFFGEL technique in the separation of the venom components of the Egyptian Elapidae Walterinnesia aegyptia snake compared to two classical methods of separation, SEC and RP-HPLC. We demonstrate that OFFGEL separates venom components over a larger scale of fractions, preserve respectable resolution with regard to the presence of a given compound in adjacent fractions and allows the identification of a greater number of ions by MS (102 over 134 total ions). We also conclude that applying several separating techniques (SEC and RP-HPLC in addition to OFFGEL) provides complementary results in terms of ion detection (21 more for SEC and 22 more with RP-HPLC). As a result, we provide a complete list of 134 ions present in the venom of W. aegyptia by using all these techniques combined. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Analytical Quality by Design Approach in RP-HPLC Method Development for the Assay of Etofenamate in Dosage Forms

    PubMed Central

    Peraman, R.; Bhadraya, K.; Reddy, Y. Padmanabha; Reddy, C. Surayaprakash; Lokesh, T.

    2015-01-01

    By considering the current regulatory requirement for an analytical method development, a reversed phase high performance liquid chromatographic method for routine analysis of etofenamate in dosage form has been optimized using analytical quality by design approach. Unlike routine approach, the present study was initiated with understanding of quality target product profile, analytical target profile and risk assessment for method variables that affect the method response. A liquid chromatography system equipped with a C18 column (250×4.6 mm, 5 μ), a binary pump and photodiode array detector were used in this work. The experiments were conducted based on plan by central composite design, which could save time, reagents and other resources. Sigma Tech software was used to plan and analyses the experimental observations and obtain quadratic process model. The process model was used for predictive solution for retention time. The predicted data from contour diagram for retention time were verified actually and it satisfied with actual experimental data. The optimized method was achieved at 1.2 ml/min flow rate of using mobile phase composition of methanol and 0.2% triethylamine in water at 85:15, % v/v, pH adjusted to 6.5. The method was validated and verified for targeted method performances, robustness and system suitability during method transfer. PMID:26997704

  16. Bioactive compounds, RP-HPLC analysis of phenolics, and antioxidant activity of some Portuguese shrub species extracts.

    PubMed

    Luís, Angelo; Domingues, Fernanda; Duarte, Ana Paula

    2011-12-01

    In the ecosystem of Serra Da Estrela, some plant species have the potential to be used as raw material for extraction of bioactive products. The goal of this work was to determine the phenolic, flavonoid, tannin and alkaloid contents of the methanolic extracts of some shrubs (Echinospartum ibericum, Pterospartum tridentatum, Juniperus communis, Ruscus aculeatus, Rubus ulmifolius, Hakea sericea, Cytisus multiflorus, Crataegus monogyna, Erica arborea and Ipomoea acuminata), and then to correlate the phenolic compounds and flavonoids with the antioxidant activity of each extract. The Folin-Ciocalteu's method was used for the determination of total phenols, and tannins were then precipitated with polyvinylpolypyrrolidone (PVPP); a colorimetric method with aluminum chloride was used for the determination of flavonoids, and a Dragendorff's reagent method was used for total alkaloid estimation. The 2,2-diphenyl-1-picrylhydrazyl (DPPH) and beta-carotene bleaching tests were used to assess the antioxidant activity of extracts. The identification of phenolic compounds present in extracts was performed using RP-HPLC. A positive linear correlation between antioxidant activity index and total phenolic content of methanolic extracts was observed. The RP-HPLC procedure showed that the most common compounds were ferulic and ellagic acids and quercetin. Most of the studied shrubs have significant antioxidant properties that are probably due to the existence of phenolic compounds in the extracts. It is noteworthy to emphasize that for Echinospartum ibericum, Hakea sericea and Ipomoea acuminata, to the best of our knowledge, no phytochemical studies have been undertaken nor their use in traditional medicine been described.

  17. Analytical Characterization of an Oil-in-Water Adjuvant Emulsion.

    PubMed

    Sun, Jenny; Remmele, Richard L; Sanyal, Gautam

    2017-07-01

    Adjuvants are typically used in subunit vaccine formulations to enhance immune responses elicited by individual antigens. Physical chemical characterization of novel adjuvants is an important step in ensuring their effective use in vaccine formulations. This paper reports application of a panel of quantitative assays developed to analyze and characterize an oil-in-water adjuvant emulsion, which contains glucopyranosyl lipid A (GLA) and is a squalene-based emulsion. GLA is a fully synthetic analogue of monophosphoryl lipid A, which is a Toll-like receptor type 4 agonist and an FDA-approved adjuvant. The GLA-stable emulsion (GLA-SE) is currently being used for a respiratory syncytial virus vaccine in a phase 2 clinical trial. GLA was quantitated using reverse-phased high-performance liquid chromatography (RP-HPLC) coupled to a mass spectrometric detector, achieving higher assay sensitivity than the charged aerosol detection routinely used. Quantitation of the excipients of GLA-SE, including squalene, egg phosphatidyl choline, and Poloxamer 188, was achieved using a simple and rapid RP-HPLC method with evaporative light scattering detection, eliminating chemical derivatization typically required for these chromophore-lacking compounds. DL-α-tocopherol, the antioxidant of the GLA-SE, was quantitated using a RP-HPLC method with conventional UV detection. The experimental results compared well with values expected for these compounds based on targeted composition of the adjuvant. The assays were applied to identify degradation of individual components in a GLA-SE sample that degraded into distinct aqueous and oil phases. The methods developed and reported here are effective tools in monitoring physicochemical integrity of the adjuvant, as well as in formulation studies.

  18. Improved method for HPLC analysis of polyamines, agmatine and aromatic monoamines in plant tissue

    NASA Technical Reports Server (NTRS)

    Slocum, R. D.; Flores, H. E.; Galston, A. W.; Weinstein, L. H.

    1989-01-01

    The high performance liquid chromatographic (HPLC) method of Flores and Galston (1982 Plant Physiol 69: 701) for the separation and quantitation of benzoylated polyamines in plant tissues has been widely adopted by other workers. However, due to previously unrecognized problems associated with the derivatization of agmatine, this important intermediate in plant polyamine metabolism cannot be quantitated using this method. Also, two polyamines, putrescine and diaminopropane, also are not well resolved using this method. A simple modification of the original HPLC procedure greatly improves the separation and quantitation of these amines, and further allows the simulation analysis of phenethylamine and tyramine, which are major monoamine constituents of tobacco and other plant tissues. We have used this modified HPLC method to characterize amine titers in suspension cultured carrot (Daucas carota L.) cells and tobacco (Nicotiana tabacum L.) leaf tissues.

  19. High performance liquid chromatographic determination of caffeine in decaffeinated coffee, tea, and beverage products.

    PubMed

    Ashoor, S H; Seperich, G J; Monte, W C; Welty, J

    1983-05-01

    A method was developed for determining caffeine in decaffeinated coffee, tea, and beverage products by high performance liquid chromatography (HPLC). The HPLC system consisted of a Bio-Sil ODS-5S C18 column, methanol-water (25 + 75) mobile phase at 1 mL/min, and a UV detector. The method is simple and specific. Caffeine recoveries were 93.8-98.3% and coefficients of variation were 0.90-2.25%.

  20. Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection.

    PubMed

    Zhang, Kelly; Li, Yi; Tsang, Midco; Chetwyn, Nik P

    2013-09-01

    To overcome challenges in HPLC impurity analysis of pharmaceuticals, we developed an automated online multi-heartcutting 2D HPLC system with hyphenated UV-charged aerosol MS detection. The first dimension has a primary column and the second dimension has six orthogonal columns to enhance flexibility and selectivity. The two dimensions were interfaced by a pair of switching valves equipped with six trapping loops that allow multi-heartcutting of peaks of interest in the first dimension and also allow "peak parking." The hyphenated UV-charged aerosol MS detection provides comprehensive detection for compounds with and without UV chromophores, organics, and inorganics. It also provides structural information for impurity identification. A hidden degradation product that co-eluted with the drug main peak was revealed by RP × RP separation and thus enabled the stability-indicating method development. A poorly retained polar component with no UV chromophores was analyzed by RP × hydrophilic interaction liquid chromatography separation with charged aerosol detection. Furthermore, using this system, the structures of low-level impurities separated by a method using nonvolatile phosphate buffer were identified and tracked by MS in the second dimension. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. A validated HPLC-MS/MS assay for quantifying unstable pharmacologically active metabolites of clopidogrel in human plasma: application to a clinical pharmacokinetic study.

    PubMed

    Furlong, Michael T; Savant, Ishani; Yuan, Moucun; Scott, Laura; Mylott, William; Mariannino, Thomas; Kadiyala, Pathanjali; Roongta, Vikram; Arnold, Mark E

    2013-05-01

    Clopidogrel is prescribed for the treatment of Acute Coronary Syndrome and recent myocardial infarction, recent stroke, or established peripheral arterial disease. A sensitive and reliable high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay was developed and validated to enable reliable quantification of four diastereomeric and chemically reactive thiol metabolites, two of which are pharmacologically active, in human plasma. The metabolites were stabilized by alkylation of their reactive thiol moieties with 2-bromo-3'-methoxyacetophenone (MPB). Following organic solvent mediated-protein precipitation in a 96-well plate format, chromatographic separation was achieved by gradient elution on an Ascentis Express RP-amide column. Chromatographic conditions were optimized to ensure separation of the four derivatized active metabolites. Derivatized metabolites and stable isotope-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The HPLC-MS/MS assay was validated over concentration ranges of 0.125-125 ng/mL for metabolites H1-H3 and 0.101-101 ng/mL for H4. Intra- and inter-assay precision values for replicate quality control samples were within 14.3% for all analytes during the assay validation. Mean quality control accuracy values were within ±6.3% of nominal values for all analytes. Assay recoveries were high (>79%). The four derivatized analytes were stable in human blood for at least 2 h at room temperature and on ice. The analytes were also stable in human plasma for at least 25 h at room temperature, 372 days at -20 °C and -70 °C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of all four thiol metabolites in human plasma in support of a human pharmacokinetic study. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Development and Validation of a Stability-Indicating Assay of Etofenamate by RP-HPLC and Characterization of Degradation Products

    PubMed Central

    Peraman, Ramalingam; Nayakanti, Devanna; Dugga, Hari Hara Theja; Kodikonda, Sudhakara

    2013-01-01

    A validated stability-indicating RP-HPLC method for etofenamate (ETF) was developed by separating its degradation products on a C18 (250 mm × 4.6 mm 5 μm) Qualisil BDS column using a phosphate buffer (pH-adjusted to 6.0 with orthophosphoric acid) and methanol in the ratio of 20:80 % v/v as the mobile phase at a flow rate of 1.0 mL/min. The column effluents were monitored by a photodiode array detector set at 286 nm. The method was validated in terms of specificity, linearity, accuracy, precision, detection limit, quantification limit, and robustness. Forced degradation of etofenamate was carried out under acidic, basic, thermal, photo, and peroxide conditions and the major degradation products of acidic and basic degradation were isolated and characterized by 1H-NMR, 13C-NMR, and mass spectral studies. The mass balance of the method varied between 92–99%. PMID:24482770

  3. Validation of a HPLC method for determination of hydroxymethylfurfural in crude palm oil.

    PubMed

    Ariffin, Abdul Azis; Ghazali, H M; Kavousi, Parviz

    2014-07-01

    For the first time 5-hydroxymethyl-2-furaldehyde (HMF) was separated from crude palm oil (CPO), and its authenticity was determined using an RP-HPLC method. Separation was accomplished with isocratic elution of a mobile phase comprising water and methanol (92:8 v/v) on a Purospher Star RP-18e column (250mm×4.6mm, 5.0μm). The flow rate was adjusted to 1ml/min and detection was performed at 284nm. The method was validated, and results obtained exhibit a good recovery (95.58% to 98.39%). Assessment of precision showed that the relative standard deviations (RSD%) of retention times and peak areas of spiked samples were less than 0.59% and 2.66%, respectively. Further, the limit of detection (LOD) and LOQ were 0.02, 0.05mg/kg, respectively, and the response was linear across the applied ranges. The crude palm oil samples analysed exhibited HMF content less than 2.27mg/kg. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Paired-ion chromatography and high performance liquid chromatography of labetalol in feeds.

    PubMed

    Townley, E R; Ross, B

    1980-11-01

    A high performance liquid chromatographic (HPLC) method using reverse phase paired-ion chromatography and ultraviolet detection at 280 nm has been developed to determine labetalol, an alpha and beta adrenoceptor blocking agent, in Purina No. 5001 rodent chow. The method is simple and rapid, and demonstrates a separation technique applicable to other acidic and basic drugs. It requires only extraction of the drug with methanol--water--acetic acid (66 + 33 + 1) and separation of insoluble material by filtration before HPLC. Labetalol, is chromatographically separated from soluble feed components by means of a microBondapak C18 column and methanol--water--acetic acid (66 + 33 + 1) mobile phase, 0.005M with respect to sodium dioctylsulfosuccinate paired-ion reagent. Average recovery is 98.7% with a relative standard deviation of +/- 2.3% for the equipment described.

  5. High-efficiency high performance liquid chromatographic analysis of red wine anthocyanins.

    PubMed

    de Villiers, André; Cabooter, Deirdre; Lynen, Frédéric; Desmet, Gert; Sandra, Pat

    2011-07-22

    The analysis of anthocyanins in natural products is of significant relevance in recent times due to the recognised health benefits associated with their consumption. In red grapes and wines in particular, anthocyanins are known to contribute important properties to the sensory (colour and taste), anti-oxidant- and ageing characteristics. However, the detailed investigation of the alteration of these compounds during wine ageing is hampered by the challenges associated with the separation of grape-derived anthocyanins and their derived products. High performance liquid chromatography (HPLC) is primarily used for this purpose, often in combination with mass spectrometric (MS) detection, although conventional HPLC methods provide incomplete resolution. We have previously demonstrated how on-column inter-conversion reactions are responsible for poor chromatographic efficiency in the HPLC analysis of anthocyanins, and how an increase in temperature and decrease in particle size may improve the chromatographic performance. In the current contribution an experimental configuration for the high efficiency analysis of anthocyanins is derived using the kinetic plot method (KPM). Further, it is shown how analysis under optimal conditions, in combination with MS detection, delivers much improved separation and identification of red wine anthocyanins and their derived products. This improved analytical performance holds promise for the in-depth investigation of these influential compounds in wine during ageing. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. [HPLC fingerprint of flavonoids in Sophora flavescens and determination of five components].

    PubMed

    Ma, Hong-Yan; Zhou, Wan-Shan; Chu, Fu-Jiang; Wang, Dong; Liang, Sheng-Wang; Li, Shao

    2013-08-01

    A simple and reliable method of high-performance liquid chromatography with photodiode array detection (HPLC-DAD) was developed to evaluate the quality of a traditional Chinese medicine Sophora flavescens through establishing chromatographic fingerprint and simultaneous determination of five flavonoids, including trifolirhizin, maackiain, kushenol I, kurarinone and sophoraflavanone G. The optimal conditions of separation and detection were achieved on an ULTIMATE XB-C18 column (4.6 mm x 250 mm, 5 microm) with a gradient of acetonitrile and water, detected at 295 nm. In the chromatographic fingerprint, 13 peaks were selected as the characteristic peaks to assess the similarities of different samples collected from different origins in China according to similarity evaluation for chromatographic fingerprint of traditional chinese medicine (2004AB) and principal component analysis (PCA) were used in data analysis. There were significant differences in the fingerprint chromatograms between S. flavescens and S. tonkinensis. Principal component analysis showed that kurarinone and sophoraflavanone G were the most important component. In quantitative analysis, the five components showed good regression (R > 0.999) with linear ranges, and their recoveries were in the range of 96.3% - 102.3%. This study indicated that the combination of quantitative and chromatographic fingerprint analysis can be readily utilized as a quality control method for S. flavescens and its related traditional Chinese medicinal preparations.

  7. Stability Indicating HPLC Method for Simultaneous Determination of Mephenesin and Diclofenac Diethylamine

    PubMed Central

    Mulgund, S. V.; Phoujdar, M. S.; Londhe, S. V.; Mallade, P. S.; Kulkarni, T. S.; Deshpande, A. S.; Jain, K. S.

    2009-01-01

    A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 μg/ml and 10-60 μg/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H2O2, photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations. PMID:20177453

  8. Stability indicating HPLC method for simultaneous determination of mephenesin and diclofenac diethylamine.

    PubMed

    Mulgund, S V; Phoujdar, M S; Londhe, S V; Mallade, P S; Kulkarni, T S; Deshpande, A S; Jain, K S

    2009-01-01

    A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 mug/ml and 10-60 mug/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H(2)O(2), photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations.

  9. Estimation of simvastatin and cetirizine by RP-LC method: Application to freeze and thaw (FT) stability studies.

    PubMed

    Naveed, Safila; Usmanghani, Khan; Sana, Aisha; Ali, Huma; Zafar, Farya; Qamar, Fatima; Sarwer, Ghulam; Abbas, Sarah; Alam, M Tanweer; Shinwari, Muhammad Ibrar

    2018-01-01

    Sensitive, simple, reliable and rapid HPLC technique for the estimation of simvastatin (SMV) and cetirizine has been designed in this study. The chromatographic conditions were set using Shimadzu LC-10 AT VP pump, with UV detector (SPD-10 AV-VP). System integration was performed with CBM-102 (Bus Module). Partitioning of components was attained with pre-packed C-18 column of Purospher Star (5 μm, 250 x 4.6 mm) at ambient conditions. Injected volume of sample was 10 μl. Mobile phase was composed of 50:50 v/v ratio of Acetonitrile/water (pH 3.0 adjusted with ortho-phosphoric acid) having 2 ml/minutes rate of flow. Compounds were detected in UV region at 225 nm. Percent Recovery of simvastatin was observed in the range of 98-102%. All results were found in accept table range of specification. The projected method is consistent, specific, precise, and rapid, that can be employed to quantitate the SMV along with cetirizine HCl. It was estimated by 3 successive cycles of freeze and thaw stability. Results of FT samples were found within accept table limits the method was developed and validated in raw materials, bulk formulations and final drug products.

  10. Development of a novel amide-silica stationary phase for the reversed-phase HPLC separation of different classes of phytohormones.

    PubMed

    Aral, Hayriye; Aral, Tarık; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep

    2013-11-15

    A novel amide-bonded silica stationary phase was prepared starting from N-Boc-phenylalanine, cyclohexylamine and spherical silica gel (4 µm, 60 Å). The amide ligand was synthesised with high yield. The resulting amide bonded stationary phase was characterised by SEM, IR and elemental analysis. The resulting selector bearing a polar amide group is used for the reversed-phase chromatography separation of different classes of thirteen phytohormones (plant hormones). The chromatographic behaviours of these analytes on the amide-silica stationary phase were compared with those of RP-C18 column under same conditions. The effects of different separation conditions, such as mobile phase, pH value, flow rate and temperature, on the separation and retention behaviours of the 13 phytohormones in this system were studied. The optimum separation was achieved using reversed-phase HPLC gradient elution with an aqueous mobile phase containing pH=6.85 potassium phosphate buffer (20 mM) and acetonitrile with a 22 °C column temperature. Under these experimental conditions, the 12 phytohormones could be separated and detected at 230 or 270 nm within 26 min. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Characterization of celiac disease related oat proteins: bases for the development of high quality oat varieties suitable for celiac patients.

    PubMed

    Giménez, María J; Real, Ana; García-Molina, M Dolores; Sousa, Carolina; Barro, Francisco

    2017-02-17

    Some studies have suggested that the immunogenicity of oats depends on the cultivar. RP-HPLC has been proposed as a useful technique to select varieties of oats with reduced immunogenicity. The aim of this study was to identify both the avenin protein patterns associated with low gluten content and the available variability for the development of new non-toxic oat cultivars. The peaks of alcohol-soluble avenins of a collection of landraces and cultivars of oats have been characterized based on the RP-HPLC elution times. The immunotoxicity of oat varieties for patients with celiac disease (CD) has been tested using a competitive ELISA based on G12 monoclonal antibody. The oat lines show, on average, seven avenin peaks giving profiles with certain similarities. Based on this similarity, most of the accessions have been grouped into avenin patterns. The variability of RP-HPLC profiles of the collection is great, but not sufficient to uniquely identify the different varieties of the set. Overall, the immunogenicity of the collection is less than 20 ppm. However, there is a different distribution of toxicity ranges between the different peak patterns. We conclude that the RP-HPLC technique is useful to establish groups of varieties differing in degree of toxicity for CD patients.

  12. Characterization of celiac disease related oat proteins: bases for the development of high quality oat varieties suitable for celiac patients

    PubMed Central

    Giménez, María J.; Real, Ana; García-Molina, M. Dolores; Sousa, Carolina; Barro, Francisco

    2017-01-01

    Some studies have suggested that the immunogenicity of oats depends on the cultivar. RP-HPLC has been proposed as a useful technique to select varieties of oats with reduced immunogenicity. The aim of this study was to identify both the avenin protein patterns associated with low gluten content and the available variability for the development of new non-toxic oat cultivars. The peaks of alcohol-soluble avenins of a collection of landraces and cultivars of oats have been characterized based on the RP-HPLC elution times. The immunotoxicity of oat varieties for patients with celiac disease (CD) has been tested using a competitive ELISA based on G12 monoclonal antibody. The oat lines show, on average, seven avenin peaks giving profiles with certain similarities. Based on this similarity, most of the accessions have been grouped into avenin patterns. The variability of RP-HPLC profiles of the collection is great, but not sufficient to uniquely identify the different varieties of the set. Overall, the immunogenicity of the collection is less than 20 ppm. However, there is a different distribution of toxicity ranges between the different peak patterns. We conclude that the RP-HPLC technique is useful to establish groups of varieties differing in degree of toxicity for CD patients. PMID:28209962

  13. Stability indicating simplified HPLC method for simultaneous analysis of resveratrol and quercetin in nanoparticles and human plasma.

    PubMed

    Kumar, Sandeep; Lather, Viney; Pandita, Deepti

    2016-04-15

    Resveratrol and quercetin are well-known polyphenolic compounds present in common foods, which have demonstrated enormous potential in the treatment of a wide variety of diseases. Owing to their exciting synergistic potential and combination delivery applications, we developed a simple and rapid RP-HPLC method based on isosbestic point detection. The separation was carried out on phenomenex Synergi 4μ Hydro-RP 80A column using methanol: acetonitrile (ACN): 0.1% phosphoric acid (60:10:30) as mobile phase. The method was able to quantify nanograms of analytes simultaneously on a single wavelength (269 nm), making it highly sensitive, rapid as well as economical. Additionally, forced degradation studies of resveratrol and quercetin were established and the method's applicability was evaluated on PLGA nanoparticles and human plasma. The analytes peaks were found to be well resolved in the presence of degradation products and excipients. The simplicity of the developed method potentializes its suitability for routine in vitro and in vivo analysis of resveratrol and quercetin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Development and validation of chemometrics-assisted spectrophotometric and liquid chromatographic methods for the simultaneous determination of two multicomponent mixtures containing bronchodilator drugs.

    PubMed

    El-Gindy, Alaa; Emara, Samy; Shaaban, Heba

    2007-02-19

    Three methods are developed for the determination of two multicomponent mixtures containing guaiphenesine (GU) with salbutamol sulfate (SL), methylparaben (MP) and propylparaben (PP) [mixture 1]; and acephylline piperazine (AC) with bromhexine hydrochloride (BX), methylparaben (MP) and propylparaben (PP) [mixture 2]. The resolution of the two multicomponent mixtures has been accomplished by using numerical spectrophotometric methods such as partial least squares (PLS-1) and principal component regression (PCR) applied to UV absorption spectra of the two mixtures. In addition HPLC method was developed using a RP 18 column at ambient temperature with mobile phase consisting of acetonitrile-0.05 M potassium dihydrogen phosphate, pH 4.3 (60:40, v/v), with UV detection at 243 nm for mixture 1, and mobile phase consisting of acetonitrile-0.05 M potassium dihydrogen phosphate, pH 3 (50:50, v/v), with UV detection at 245 nm for mixture 2. The methods were validated in terms of accuracy, specificity, precision and linearity in the range of 20-60 microg ml(-1) for GU, 1-3 microg ml(-1) for SL, 20-80 microg ml(-1) for AC, 0.2-1.8 microgml(-1) for PP and 1-5 microg ml(-1) for BX and MP. The proposed methods were successfully applied for the determination of the two multicomponent combinations in laboratory prepared mixtures and commercial syrups.

  15. HPLC Determination of Esculin and Esculetin in Rat Plasma for Pharmacokinetic Studies.

    PubMed

    Rehman, Shaheed Ur; Kim, In Sook; Kang, Ki Sung; Yoo, Hye Hyun

    2015-09-01

    An optimized, sensitive and validated reversed-phase high-performance liquid chromatography (RP-HPLC) method with UV detection is described for simultaneous determination of esculin and its aglycone, esculetin, in rat plasma. After addition of internal standard (chrysin), plasma samples were pretreated by solid-phase extraction and introduced into the HPLC system. Analytes were separated on a RP C18 column with a mobile phase of 0.075% acetic acid in water (solvent A) and 90% acetonitrile in solvent A (solvent B) using gradient elution at a flow rate of 1.0 mL/min. The wavelength for UV detection was set at 338 nm. Calibration curves for esculin and esculetin were constructed over a range of 10-1,000 ng/mL. The developed method was found to be specific, precise and accurate. The method was successfully applied to study the pharmacokinetics of esculin and esculetin in rats. After oral administration of 120 mg/kg, the mean Cmax values were 340.3 and 316.5 ng/mL and the AUClast values were 377.3 and 1276.5 h ng/mL for esculin and esculetin, respectively. The bioavailability of esculin was calculated to be 0.62%. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Discovery of C5-C17 poly- and perfluoroalkyl substances in water by in-line SPE-HPLC-Orbitrap with in-source fragmentation flagging.

    PubMed

    Liu, Yanna; Pereira, Alberto Dos Santos; Martin, Jonathan W

    2015-04-21

    The presence of unknown organofluorine compounds in environmental samples has prompted the development of nontargeted analytical methods capable of detecting new perfluoroalkyl and polyfluoroalkyl substances (PFASs). By combining high volume injection with high performance liquid chromatography (HPLC) and ultrahigh resolution Orbitrap mass spectrometry, a sensitive (0.003-0.2 ng F/mL for model mass-labeled PFASs) untargeted workflow was developed for discovery and characterization of novel PFASs in water. In the first step, up to 5 mL of water is injected to in-line solid phase extraction, chromatographed by HPLC, and detected by electrospray ionization with mass spectral acquisition in parallel modes cycling back and forth: (i) full scan with ultrahigh resolving power (RP = 120,000, mass accuracy ≤3 ppm), and (ii) in-source fragmentation flagging scans designed to yield marker fragment ions including [C2F5](-) (m/z 118.992), [C3F7](-) (m/z 168.988), [SO4H](-) (m/z 96.959), and [Cl](-) (m/z 34.9). For flagged PFASs, plausible empirical formulas were generated from accurate masses, isotopic patterns, and fragment ions. In the second step, another injection is made to collect high resolution MS/MS spectra of suspect PFAS ions, allowing further confirmation of empirical formulas while also enabling preliminary structural characterization. The method was validated by applying it to an industrial wastewater, and 36 new PFASs were discovered. Of these, 26 were confidently assigned to 3 new PFAS classes that have not previously been reported in the environment: polyfluorinated sulfates (CnFn+3Hn-2SO4(-); n = 5, 7, 9, 11, 13, and 15), chlorine substituted perfluorocarboxylates (ClCnF2nCO2(-); n = 4-11), and hydro substituted perfluorocarboxylates (HCnF2nCO2(-); n = 5-16). Application of the technique to environmental water samples is now warranted.

  17. HPLC-PFD determination of priority pollutant PAHs in water, sediment, and semipermeable membrane devices

    USGS Publications Warehouse

    Williamson, K.S.; Petty, J.D.; Huckins, J.N.; Lebo, J.A.; Kaiser, E.M.

    2002-01-01

    High performance liquid chromatography coupled with programmable fluorescence detection was employed for the determination of 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs) in water, sediment, and semipermeable membrane devices (SPMDs). Chromatographic separation using this analytical method facilitates selectivity, sensitivity (ppt levels), and can serve as a non-destructive technique for subsequent analysis by other chromatographic and spectroscopic techniques. Extraction and sample cleanup procedures were also developed for water, sediment, and SPMDs using various chromatographic and wet chemical methods. The focus of this publication is to examine the enrichment techniques and the analytical methodologies used in the isolation, characterization, and quantitation of 15 PPPAHs in different sample matrices.

  18. [HPLC fingerprint analysis of flavonoids of phyllanthi fructus from different habitats].

    PubMed

    Wang, Fei; Wang, Shuai; Meng, Xian-sheng; Bao, Yong-rui; Zhu, Ying-huan

    2014-11-01

    To establish the HPLC fingerprint of flavonoids of Phyllanthi Fructus from different habitats. HPLC method was adopted. The flavonoids composition of Phyllanthi Fructus from 10 different habitats was determined on an Agilent C, chromatographic column with 0. 5% formic acid water (A)-acetonitrile (B) as the mobile phase in gradient elution under the wavelength of 254 nm. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus were established to evaluate the qualitiy of them. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus from 10 different habitats were established. 18 common peaks were found and the similarities of them were more than 0. 90 except the ones from Guangxi and Guangdong. The method is simple, accurate and repeatable. It can be used for research and quality control of the effective components in Phyllanthi Fructus.

  19. A validated specific stability-indicating RP-HPLC assay method for Ambrisentan and its related substances.

    PubMed

    Narayana, M B V; Chandrasekhar, K B; Rao, B M

    2014-09-01

    A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. A validated stability-indicating RP-HPLC method for levofloxacin in the presence of degradation products, its process related impurities and identification of oxidative degradant.

    PubMed

    Lalitha Devi, M; Chandrasekhar, K B

    2009-12-05

    The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of levofloxacin as well as its related substances determination in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its process related impurities. Forced degradation studies were performed on bulk sample of levofloxacin as per ICH prescribed stress conditions using acid, base, oxidative, water hydrolysis, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during oxidative stress and the degradation product formed was identified by LCMS/MS, slight degradation in acidic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process related impurities and degradation products from the analyte were achieved on ACE C18 column using the mobile phase consists a mixture of 0.5% (v/v) triethyl amine in sodium dihydrogen orthophosphate dihydrate (25 mM; pH 6.0) and methanol using a simple linear gradient. The detection was carried out at 294 nm. The limit of detection and the limit of quantitation for the levofloxacin and its process related impurities were established. The stressed test solutions were assayed against the qualified working standard of levofloxacin and the mass balance in each case was in between 99.4 and 99.8% indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of levofloxacin at the time of batch release and also during its stability studies (long term and accelerated stability).

  1. Rapid and sensitive method for determination of withaferin-A in human plasma by HPLC.

    PubMed

    Patial, Pankaj; Gota, Vikram

    2011-02-01

    To develop and validate a rapid and sensitive high-performance liquid chromatographic method for determination of withaferin-A in human plasma. Withaferin-A, the active molecule of a traditional Indian herb, has demonstrated several biological activities in preclinical models. A validated bioassay is not available for its pharmacokinetic evaluation. The chromatographic system used a reverse-phase C18 column with UV-visible detection at 225 nm. The mobile phase consisted of water and acetonitrile applied in a gradient flow. Withaferin-A was extracted by simple protein-precipitation technique. The calibration curve was linear in the concentration range of 0.05-1.6 µg/ml. The method has the desired sensitivity to detect the plasma concentration range of withaferin-A that is likely to show biological activity based on in vitro data. This is the first HPLC method ever described for the estimation of withaferin-A in human plasma which could be applied for pharmacokinetic studies.

  2. Separation and quantitation of colour pigments of chili powder (Capsicum frutescens) by high-performance liquid chromatography-diode array detection.

    PubMed

    Cserháti, T; Forgács, E; Morais, M H; Mota, T; Ramos, A

    2000-10-27

    The performance of reversed-phase thin-layer (RP-TLC) and reversed-phase high-performance liquid chromatography (RP-HPLC) was compared for the separation and determination of the colour pigments of chili (Capsicum frutescens) powder using a wide variety of eluent systems. No separation of pigments was achieved in RP-TLC, however, it was established that tetrahydrofuran shows an unusually high solvent strength. RP-HPLC using water-methanol-acetonitrile gradient elution separated the chili pigments in many fractions. Diode array detection (DAD) indicated that yellow pigments are eluted earlier than the red ones and chili powder contains more yellow pigments than common paprika powders. It was established that the very different absorption spectra of pigments make the use of DAD necessary.

  3. Simultaneous determination of secondary metabolites from Vinca rosea plant extractives by reverse phase high performance liquid chromatography

    PubMed Central

    Siddiqui, Mohammad Jamshed Ahmad; Ismail, Zhari; Saidan, Noor Hafizoh

    2011-01-01

    Background: Vinca rosea (Apocynaceae) is one of the most important and high value medicinal plants known for its anticancer alkaloids. It is the iota of the isolated secondary metabolites used in chemotherapy to treat diverse cancers. Several high performance liquid chromatography (HPLC) methods have been developed to quantify the active alkaloids in the plant. However, this method may serve the purpose in quantification of V. rosea plant extracts in totality. Objective: To develop and validate the reverse phase (RP)-HPLC method for simultaneous determination of secondary metabolites, namely alkaloids from V. rosea plant extracts. Materials and Methods: The quantitative determination was conducted by RP-HPLC equipped with ultraviolet detector. Optimal separation was achieved by isocratic elution with mobile phase consisting of methanol:acetonitrile:ammonium acetate buffer (25 mM) with 0.1% triethylamine (15:45:40 v/v) on a column (Zorbax Eclipse plus C18, 250 mm % 4.6 mm; 5 μm). The standard markers (vindoline, vincristine, catharanthine, and vinblastine) were identified by retention time and co-injected with reference standard and quantified by external standard method at 297 nm. Results: The precision of the method was confirmed by the relative standard deviation (R.S.D.), which was lower than 2.68%. The recoveries were in the range of 98.09%-108%. The limits of detection (LOD) for each marker alkaloids were lower than 0.20 μg. Different parts of the V. rosea extracts shows different concentrations of markers, flower samples were high in vinblastine content, while methanol extract from the leaves contains all the four alkaloids in good yield, and there is no significant presence of markers in water extracts. Conclusion: HPLC method established is appropriate for the standardization and quality assurance of V. rosea plant extracts. PMID:21716929

  4. Analysis of Poly-β-Hydroxybutyrate in Rhizobium japonicum Bacteroids by Ion-Exclusion High-Pressure Liquid Chromatography and UV Detection †

    PubMed Central

    Karr, Dale B.; Waters, James K.; Emerich, David W.

    1983-01-01

    Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis. PMID:16346443

  5. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Fought, E.R.

    1989-09-19

    A moving belt interface is described for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer. 8 figs.

  6. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Fought, Eric R.

    1989-01-01

    A moving belt interface for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer.

  7. Tunable release of clavam from clavam stabilized gold nanoparticles--design, characterization and antimicrobial study.

    PubMed

    Manju, V; Dhandapani, P; Gurusamy Neelavannan, M; Maruthamuthu, S; Berchmans, S; Palaniappan, A

    2015-04-01

    A facile one-step approach is developed to synthesize highly stable (up to 6months) gold nanoparticles (GNPs) using Clavam, pharmaceutical form of amoxicillin which contains a mixture of amoxicillin and potassium salt of clavulanic acid, at room temperature (25-30°C). The clavam stabilized GNPs are characterized using various techniques including UV-Visible, FT-IR spectrophotometry and transmission electron microscopy (TEM). Tunable release of clavam from clavam stabilized GNPs is demonstrated using intracellular concentrations of glutathione (GSH). The process is monitored using an UV-Vis spectroscopy and the amount of clavam released in terms of amoxicillin concentration is quantitatively estimated using reverse phase high performance liquid chromatographic (RP-HPLC) technique. In vitro study reveals that the clavam released from GNPs' surface was found to show a significant enhancement in antibacterial activity against Escherichia coli and the cause of enhancement is addressed. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Helleborus purpurascens-Amino Acid and Peptide Analysis Linked to the Chemical and Antiproliferative Properties of the Extracted Compounds.

    PubMed

    Segneanu, Adina-Elena; Grozescu, Ioan; Cziple, Florentina; Berki, Daniel; Damian, Daniel; Niculite, Cristina Mariana; Florea, Alexandru; Leabu, Mircea

    2015-12-11

    There is a strong drive worldwide to discover and exploit the therapeutic potential of a large variety of plants. In this work, an alcoholic extract of Helleborus purpurascens (family Ranunculaceae) was investigated for the identification of amino acids and peptides with putative antiproliferative effects. In our work, a separation strategy was developed using solvents of different polarity in order to obtain active compounds. Biochemical components were characterized through spectroscopic (mass spectroscopy) and chromatographic techniques (RP-HPLC and GC-MS). The biological activity of the obtained fractions was investigated in terms of their antiproliferative effects on HeLa cells. Through this study, we report an efficient separation of bioactive compounds (amino acids and peptides) from a plant extract dependent on solvent polarity, affording fractions with unaffected antiproliferative activities. Moreover, the two biologically tested fractions exerted a major antiproliferative effect, thereby suggesting potential anticancer therapeutic activity.

  9. Concurrent estimation of amlodipine besylate, hydrochlorothiazide and valsartan by RP-HPLC, HPTLC and UV-spectrophotometry.

    PubMed

    Sharma, Manish; Kothari, Charmy; Sherikar, Omkar; Mehta, Priti

    2014-01-01

    Accurate, sensitive and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC), high-performance thin-layer chromatography (HPTLC) and ultraviolet (UV) spectrophopometric methods were developed for the concurrent estimation of amlodipine besylate (AMLO), hydrochlorothiazide (HCTZ) and valsartan (VALS) in bulk and combined tablet dosage forms. For the RP-HPLC method, separation was achieved on a C18 column using potassium dihydrogen orthophosphate buffer (50 mM, pH 3.7) with 0.2% triethylamine as the modifier and acetonitrile in the ratio of 56:44 (v/v) as the mobile phase. Quantification was achieved using a photodiode array detector at 232 nm over a concentration range of 2-25 µg/mL for AMLO, 5-45 µg/mL for HCTZ and 20-150 µg/mL for VALS. For the HPTLC method, the drugs were separated by using ethyl acetate-methanol-toluene-ammonia (7.5:3:2:0.8, v/v/v/v) as the mobile phase. Quantification was achieved using UV detection at 242 nm over a concentration range of 100-600 ng/spot for AMLO, 150-900 ng/spot for HCTZ and 1,200-3,200 ng/spot for VALS. The UV-spectrophotometric simultaneous equation method was based on the measurement of absorbance at three wavelengths; i.e., at 237.6 nm (λmax of AMLO), 270.2 nm (λmax of HCTZ) and 249.2 nm (λmax of VALS) in methanol. Quantification was achieved over the concentration range of 2-20 µg/mL for AMLO, 5-25 µg/mL HCTZ and 10-50 µg/mL for VALS. All methods were validated according to International Conference on Harmonization guidelines and successfully applied to marketed pharmaceutical formulations. Additionally, the three methods were compared statistically by an analysis of variance test, which revealed no significant difference between the proposed methods with respect to accuracy and precision.

  10. An Optimized Method for the Measurement of Acetaldehyde by High-Performance Liquid Chromatography

    PubMed Central

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2011-01-01

    Background Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase, and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). Methods We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent,, time and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DPN) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison to AcH-DPN standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Results Derivatization of acetaldehyde was performed at pH 4.0 with a 80-fold molar excess of DNPH. The reaction was completed in 40 min at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-min chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media, and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. Conclusions An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small volume sampling of culture media and biological fluids. PMID:21895715

  11. Isolation and Characterization of Precise Dye/Dendrimer Ratios

    PubMed Central

    Dougherty, Casey A.; Furgal, Joseph C.; van Dongen, Mallory A.; Goodson, Theodore; Banaszak Holl, Mark M.; Manono, Janet; DiMaggio, Stassi

    2014-01-01

    Fluorescent dyes are commonly conjugated to nanomaterials for imaging applications using stochastic synthesis conditions that result in a Poisson distribution of dye/particle ratios and therefore a broad range of photophysical and biodistribution properties. We report the isolation and characterization of generation 5 poly(amidoamine) (G5 PAMAM) dendrimer samples containing 1, 2, 3, and 4 fluorescein (FC) or 6-carboxytetramethylrhodamine succinimidyl ester (TAMRA) dyes per polymer particle. For the fluorescein case, this was achieved by stochastically functionalizing dendrimer with a cyclooctyne `click' ligand, separation into sample containing precisely defined `click' ligand/particle ratios using reverse-phase high performance liquid chromatography (rp-HPLC), followed by reaction with excess azide-functionalized fluorescein dye. For the TAMRA samples, stochastically functionalized dendrimer was directly separated into precise dye/particle ratios using rp-HPLC. These materials were characterized using 1H and 19F NMR, rp-HPLC, UV-Vis and fluorescence spectroscopy, lifetime measurements, and MALDI. PMID:24604830

  12. Analysis of amide compounds in different parts of Piper ovatum Vahl by high-performance liquid chromatographic

    PubMed Central

    Silva, Daniel R.; Brenzan, Mislaine A.; Kambara, Lauro M.; Cortez, Lucia E. R.; Cortez, Diógenes A. G.

    2013-01-01

    Background: Piper ovatum (Piperaceae) has been used in traditional medicine for the treatment of inflammations and as an analgesic. Previous studies have showed important biological activities of the extracts and amides from P. ovatum leaves. Objective: In this study, a high-performance liquid chromatographic (HPLC) method was developed and validated for quantitative determination of the amides in different parts of Piper ovatum. Materials and Methods: The analysis was carried out on a Metasil ODS column (150 × 4.6 mm, 5μm) at room temperature. HPLC conditions were as follows: acetonitrile (A), and water (B), 1.0% acetic acid. The gradient elution used was 0–30 min, 0-60% A; 30–40 min, 60% A. Flow rate used was 1.0mL/min, and detection at 280nm. Results: The validation using piperlonguminine, as the standard, demonstrated that the method shows linearity (linear correlation coefficient = 0.998), precision (relative standard deviation <5%) and accuracy (mean recovery = 103.78%) in the concentration range 31.25 – 500μg/mL. The limit of detection and quantification were 1.21 and 4.03μg/mL, respectively. This method allowed the identification and quantification of piperlonguminine and piperovatine in the hydroethanolic extracts of P. ovatum obtained from the leaves, stems and roots. All the extracts showed the same chromatographic profile. The leaves and roots contained the highest concentrations of piperlonguminine and the stems and leaves showed the most concentrations of piperovatine. Conclusion: This HPLC method is suitable for routine quantitative analysis of amides in extracts of Piper ovatum and phytopharmaceuticals containing this herb. PMID:24174818

  13. The antagonistic role of chaotropic hexafluorophosphate anions and imidazolium cations composing ionic liquids applied as phase additives in the separation of tri-cyclic antidepressants.

    PubMed

    Caban, Magda; Stepnowski, Piotr

    2017-05-15

    The main advantage of alkylimidazolium cation-based ionic liquids (ILs) as phase additives in RP-HPLC is believed to be the suppression of deleterious residual free silanols in chemically modified silica stationary phases. However, up to now, the influence of ILs was usually evaluated having in mind a particular IL salt as one compound, not as a specific mixture of cations and anions. This in fact led to some misinterpretation of observed results, very often related to the suppression effect, while in fact caused by the nature of IL anions, which contribute to the elevated chaotropicity of the separation phases. In the present study, we have attempted to consider the effect gained due to the presence of both ionic liquid entities in the mobile phase used for the separation of basic compounds. Tri-cyclic antidepressants (TCAs) were taken as representative analytes. The effect of ILs on the chromatographic separation of TCAs was investigated in comparison to common mobile phase additives and by the presentation of retention factors, tailing factors and theoretical plates. In addition, an overloading study was performed for the IL-based phases for the first time. In general, it was found that the effect of chaotropic hexafluorophosphate anions in ILs is much stronger and opposite to that caused by imidazolium cations. The overloading study gives interesting information on how imidazolium cations affect the separation of cationic analytes. Finally, the usefulness of imidazolium-based ILs as mobile phase modifiers in the RP-HPLC separation of basic compounds was discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Assessment of adrenocortical activity by non-invasive measurement of faecal cortisol metabolites in dromedary camels (Camelus dromedarius).

    PubMed

    Sid-Ahmed, Omer-Elfaroug; Sanhouri, Ahmed; Elwaseela, Badr-Eldin; Fadllalah, Imad; Mohammed, Galal-Eldin Elazhari; Möstl, Erich

    2013-08-01

    The aim of this study was to determine whether glucocorticoid production could be monitored non-invasively in dromedary camels by measuring faecal cortisol metabolites (FCMs). Five Sudanese dromedaries, two males and three females, were injected with a synthetic adrenocorticotropic hormone (ACTH) analogue. Blood samples were collected pre- and post-ACTH injection. Faeces were sampled after spontaneous defecation for five consecutive days (2 days before and 3 days after ACTH injection). Baseline plasma cortisol values ranged from 0.6 to 10.8 ng/ml in males and from 1.1 to 16.6 ng/ml in females, while peak values after ACTH injection were 10.9-41.9 in males and 10-42.2 ng/ml in females. Peak blood cortisol values were reached between 1.5 and 2.0 h after ACTH injection. The concentration of FCMs increased after ACTH injection in the faeces of both sexes, although steroid levels peaked earlier in males [24 h; (286.7-2,559.7 ng/g faeces)] than in females [36-48 h; (1,182.6-5,169.1 ng/g faeces)], reflecting increases of 3.1-8.3- and 4.3-8-fold above baseline levels. To detect chromatographic patterns of immunoreactive FCMs, faecal samples with high FCM concentrations from both sexes were pooled and subjected to reverse phase high performance liquid chromatography (RP-HPLC). RP-HPLC analysis revealed sex differences in the polarity of FCMs, with females showing more polar FCMs than males. We concluded that stimulation of adrenocortical activity by ACTH injection resulted in a measurable increase in blood cortisol that was reliably paralleled by increases in FCM levels. Thus, measurement of FCMs is a powerful tool for monitoring the adrenocortical responses of dromedaries to stressors in field conditions.

  15. Application of perfluorinated acids as ion-pairing reagents for reversed-phase chromatography and retention-hydrophobicity relationships studies of selected beta-blockers.

    PubMed

    Flieger, J

    2010-01-22

    The addition of the homologous series of perfluorinated acids-trifluoroacetic acid (TFAA), pentafluoropropionic acid (PFPA), heptafluorobutyric acid (HFBA) to mobile phases for reversed-phase high-performance liquid chromatography (RP-HPLC) of beta-blockers was tested. Acidic modifiers were responsible for acidification of mobile phase (pH 3) ensuring the protonation of the beta-blockers and further ion pairs creation. The effect of the type and concentration of mobile phase additives on retention parameters, the efficiency of the peaks, their symmetry and separation selectivity of the beta-blockers mixture were all studied. It appeared that at increasing acid concentration, the retention factor, for all compounds investigated, increased to varying degrees. It should be stressed that the presence of acids more significantly affected the retention of the most hydrophobic beta-blockers. Differences in hydrophobicity of drugs can be maximized through variation of the hydrophobicity of additives. Thus, the relative increase in the retention depends on either concentration and hydrophobicity of the anionic mobile phase additive or hydrophobicity of analytes. According to QSRR (quantitative structure retention relationship) methodology, chromatographic lipophilicity parameters: isocratic log k and log k(w) values (extrapolated retention to pure water) were correlated with the molecular (log P(o/w)) and apparent (log P(app)) octanol-water partition coefficients obtained experimentally by countercurrent chromatography (CCC) or predicted by Pallas software. The obtained, satisfactory retention-hydrophobicity correlations indicate that, in the case of the basic drugs examined in RP-HPLC systems modified with perfluorinated acids, the retention is mainly governed by their hydrophobicity. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Rapid determination of flavonoids and phenolic acids in grape juices and wines by RP-HPLC/DAD: Method validation and characterization of commercial products of the new Brazilian varieties of grape.

    PubMed

    Padilha, Carla Valéria da Silva; Miskinis, Gabriela Aquino; de Souza, Marcelo Eduardo Alves Olinda; Pereira, Giuliano Elias; de Oliveira, Débora; Bordignon-Luiz, Marilde Terezinha; Lima, Marcos Dos Santos

    2017-08-01

    A method for rapid determination of phenolic compounds by reversed-phase high-performance liquid chromatography (RP-HPLC), using a new column of faster resolution was validated and used to characterize commercial products produced with new grape Brazilian varieties of Northeast of Brazil. The in vitro antioxidant activity was also measured. The method showed linearity (R>0.9995), good precision (CV%<2.78), recovery (91.8-105.1%) and limits of detection (0.04-0.85mgL -1 ) and quantification (0.04-1.41mgL -1 ) according to other methods previously published with the difference of a run time of only 25min. The results obtained in the characterization of the samples differed for juices and wines from other world regions, mainly because of the high values of (-)-epigallocatechin and trans-caftaric acid. The products analyzed showed high antioxidant activity, especially the wine samples with values higher than those from wines of different regions of the world. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Analytical strategy for the assessment of the protein glycation status in uremic patients by high-performance liquid chromatography.

    PubMed

    Floridi, A; Trizza, V; Paolotti, P; Lucarelli, C

    1999-06-18

    We propose a newly integrated procedure for the analysis of furosine (early glycation product) and pentosidine (glycoxidation end-product) in plasma proteins and the simultaneous assessment of advanced glycation end-product (AGE) peptides and free pentosidine in plasma. In order to determine furosine and protein-linked pentosidine, plasma proteins were hydrolyzed in 8 M HCl and each analyte was purified by solid-phase extraction. Furosine was determined by ion-pair RP-HPLC methodology with isocratic elution and spectrophotometric detection at 280 nm and pentosidine by ion-pair RP-HPLC by using gradient elution and fluorimetric detection at 335/385 nm. To assess free pentosidine concentration and simultaneously evaluate the AGE peptides, an aliquot of plasma sample was diluted and ultrafiltered by using Centricon 10 M(r) < or = 10,000) ultrafiltration membranes. Free pentosidine and AGE peptides were analysed by ion-pair RP-HPLC, by using gradient elution and fluorimetric detection at 385 nm upon excitation at 335 nm. The HPLC methodology has been successfully used for the determination of glycation and glycoxidation protein status in uremic patients.

  18. SFC-MS/MS as an orthogonal technique for improved screening of polar analytes in anti-doping control.

    PubMed

    Parr, Maria Kristina; Wuest, Bernhard; Naegele, Edgar; Joseph, Jan F; Wenzel, Maxi; Schmidt, Alexander H; Stanic, Mijo; de la Torre, Xavier; Botrè, Francesco

    2016-09-01

    HPLC is considered the method of choice for the separation of various classes of drugs. However, some analytes are still challenging as HPLC shows limited resolution capabilities for highly polar analytes as they interact insufficiently on conventional reversed-phase (RP) columns. Especially in combination with mass spectrometric detection, limitations apply for alterations of stationary phases. Some highly polar sympathomimetic drugs and their metabolites showed almost no retention on different RP columns. Their retention remains poor even on phenylhexyl phases that show different selectivity due to π-π interactions. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to HPLC may help to overcome these issues. Selected polar drugs and metabolites were analyzed utilizing SFC separation. All compounds showed sharp peaks and good retention even for the very polar analytes, such as sulfoconjugates. Retention times and elution orders in SFC are different to both RP and HILIC separations as a result of the orthogonality. Short cycle times could be realized. As temperature and pressure strongly influence the polarity of supercritical fluids, precise regulation of temperature and backpressure is required for the stability of the retention times. As CO2 is the main constituent of the mobile phase in SFC, solvent consumption and solvent waste are considerably reduced. Graphical Abstract SFC-MS/MS vs. LC-MS/MS.

  19. RP-HPLC-fluorescence analysis of aliphatic aldehydes: application to aldehyde-generating enzymes HACL1 and SGPL1

    PubMed Central

    Mezzar, Serena; de Schryver, Evelyn; Van Veldhoven, Paul P.

    2014-01-01

    Long-chain aldehydes are commonly produced in various processes, such as peroxisomal α-oxidation of long-chain 3-methyl-branched and 2-hydroxy fatty acids and microsomal breakdown of phosphorylated sphingoid bases. The enzymes involved in the aldehyde-generating steps of these processes are 2-hydroxyacyl-CoA lyase (HACL1) and sphingosine-1-phosphate lyase (SGPL1), respectively. In the present work, nonradioactive assays for these enzymes were developed employing the Hantzsch reaction. Tridecanal (C13-al) and heptadecanal (C17-al) were selected as model compounds and cyclohexane-1,3-dione as 1,3-diketone, and the fluorescent derivatives were analyzed by reversed phase (RP)-HPLC. Assay mixture composition, as well as pH and heating, were optimized for C13-al and C17-al. Under optimized conditions, these aldehydes could be quantified in picomolar range and different long-chain aldehyde derivatives were well resolved with a linear gradient elution by RP-HPLC. Aldehydes generated by recombinant enzymes could easily be detected via this method. Moreover, the assay allowed to document activity or deficiency in tissue homogenates and fibroblast lysates without an extraction step. In conclusion, a simple, quick, and cheap assay for the study of HACL1 and SGPL1 activities was developed, without relying on expensive mass spectrometric detectors or radioactive substrates. PMID:24323699

  20. Cluster analysis of historical and modern hard red spring wheat cultivars based on parentage and HPLC analysis of gluten forming proteins

    USDA-ARS?s Scientific Manuscript database

    In this study, 30 hard red spring (HRS) wheat cultivars released between 1910 and 2013 were analyzed to determine how they cluster in terms of parentage and protein data, analyzed by reverse-phase HPLC (RP-HPLC) of gliadins, and size-exclusion HPLC (SE-HPLC) of unreduced proteins. Dwarfing genes in...

  1. Fluorescence polarization immunoassays for rapid, accurate, and sensitive determination of mycotoxins

    USDA-ARS?s Scientific Manuscript database

    Analytical methods for the determination of mycotoxins in foods are commonly based on chromatographic techniques (GC, HPLC or LC-MS). Although these methods permit a sensitive and accurate determination of the analyte, they require skilled personnel and are time-consuming, expensive, and unsuitable ...

  2. Simple method for the extraction and reversed-phase high-performance liquid chromatographic analysis of carotenoid pigments from red yeasts (Basidiomycota, Fungi).

    PubMed

    Weber, Roland W S; Anke, Heidrun; Davoli, Paolo

    2007-03-23

    A simple method for the extraction of carotenoid pigments from frozen wet cells of red yeasts (Basidiomycota) and their analysis by reversed-phase HPLC using a C(18) column and a water/acetone solvent system is described. Typical red yeast carotenoids belonging to an oxidative series from the monocyclic gamma-carotene to 2-hydroxytorularhodin and from the bicyclic beta-carotene to astaxanthin were separated. Pigment identity was confirmed by LC-atmospheric pressure chemical ionisation (APCI) mass spectrometry using similar chromatographic conditions.

  3. Rapid Quantitative Analysis of Naringenin in the Fruit Bodies of Inonotus vaninii by Two-phase Acid Hydrolysis Followed by Reversed Phase-high Performance Liquid Chromatography-ultra Violet.

    PubMed

    Guohua, Xia; Pan, Ruirong; Bao, Rui; Ge, Yanru; Zhou, Cunshan; Shen, Yuping

    2017-01-01

    Sanghuang is one of mystical traditional Chinese medicines recorded earliest 2000 years ago, that included various fungi of Inonotus genus and was well-known for antitumor effect in modern medicine. Inonotus vaninii is grown in natural forest of Northeastern China merely and used as Sanghuang commercially, but it has no quality control specification until now. This study was to establish a rapid method of two-phase acid hydrolysis followed by reversed phase-high performance liquid chromatography-ultra violet (RP-HPLC-UV) to quantify naringenin in the fruit body of I. vaninii . Sample solution was prepared by pretreatment of raw material in two-phase acid hydrolysis and the hydrolysis technology was optimized. After reconstitution, analysis was performed using RP-HPLC-UV. The method validation was investigated and the naringenin content of sample and comparison were determined. The naringenin was obtained by two-phase acid hydrolysis method, namely, 10.0 g of raw material was hydrolyzed in 200 mL of 1% sulfuric acid aqueous solution (v/v) and 400 mL of chloroform in oil bath at 110°C for 2 h. Good linearity ( r = 0.9992) was achieved between concentration of analyte and peak area. The relative standard deviation (RSD) of precision was 2.47% and the RSD of naringenin contents for repeatability was 3.13%. The accuracy was supported with recoveries at 96.37%, 97.30%, and 99.31%. The sample solution prepared using the proposed method contained higher content of naringenin than conventional method and was stable for 8 h. Due to the high efficiency of sample preparation and high reliability of the HPLC method, it is feasible to use this method for routine analysis of naringenin in the fungus. A convenient two-phase acid hydrolysis was employed to produce naringenin from raw material, and then an efficient and reliable reversed phase-high performance liquid chromatography-ultra violet method was established to monitor naringenin in the fruit bodies of Inonotus vaninii . The newly established method could be used to control the quality of the herb. Abbreviations used: RP-HPLC-UV: Reversed Phase-High Performance Liquid Chromatography-Ultra Violet, RSD: Relative Standard Deviation, EtOAc: Ethyl acetate, ACN: Acetonitrile, MeOH: Methanol, RH: Relative Humility.

  4. Development and validation of an HPLC-MS/MS method to determine clopidogrel in human plasma. Use of incurred samples to test back-conversion.

    PubMed

    Silvestro, Luigi; Gheorghe, Mihaela Cristina; Tarcomnicu, Isabela; Savu, Silviu; Savu, Simona Rizea; Iordachescu, Adriana; Dulea, Constanta

    2010-11-15

    Quantitative methods using LC-MS/MS allow achievement of adequate sensitivity for pharmacokinetic studies with clopidogrel; three such methods, with LLOQs as low as 5 pg/mL, were developed and fully validated according to the well established FDA 2001 guidelines. The chromatographic separations were performed on reversed phase columns Ascentis RP-Amide (15 cm x 2.1 mm, 5 μm), Ascentis Express C8 (10 cm x 2.1 mm, 2.7 μm) and Ascentis Express RP Amide (10 cm x 2.1 mm, 2.7 μm), respectively. Positive electrospray ionization in MRM mode was employed for the detection and a deuterated analogue (d3-clopidogrel) was used as internal standard. Linearity, precision, extraction recovery, matrix effects and stability tests on blank plasma spiked with clopidogrel and stored in different conditions met the acceptance criteria. During the analysis of the real samples from the first pharmacokinetic study, a significant increase (>100%) of the measured clopidogrel concentrations in the extracts kept in the autosampler at 10 °C was observed. Investigations led to the conclusion that most probably a back-conversion of one or more of the clopidogrel metabolites is occurring. The next methods were optimized in order to minimize this back-conversion. After a series of experiments, the adjustment of the sample preparation (e.g. processing at low temperature and introducing a clean-up step on Supelco HybridSPE-Precipitation cartridges) has proven to be the most effective in order to improve the stability of the extracts. Incurred samples of real subjects were successfully used in the validation of the last two analytical methods to evaluate the back-conversion, while tests using only the known metabolites could not detect this important problem. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    PubMed

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture media and biological fluids. Copyright © 2011 by the Research Society on Alcoholism.

  6. Characterization of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis

    PubMed Central

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)

    2014-01-01

    Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341

  7. Characterisation of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis.

    PubMed

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli Lucy

    2014-07-01

    Sweet basil, Ocimum basilicum, is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. A rapid method for isolation and purification of an anticoagulant from Whitmania pigra.

    PubMed

    Zhong, Shan; Cui, Zheng; Sakura, Naoki; Wang, Dong; Li, Jianlin; Zhai, Yan

    2007-05-01

    Whitmania pigra is common in China and has been used as a traditional Chinese anticoagulant medicine for years, but its effective components are unknown to scientists. In this article we report a rapid method for isolation and purification of an anticoagulant from W. pigra for the first time. An acetone-water extract of W. pigra was subjected to anion-exchange chromatography on a Sephadex DEAE A-50 column, and gel permeation chromatography on Sephadex G-25 and Sephadex LH-20 columns successively, which afforded a fraction with potent anticoagulant activity. An anticoagulant was isolated and purified from this fraction by reversed-phase high-performance liquid chromatography (RP-HPLC). It was identified as a single pure substance by RP-HPLC and sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE). This component was named whitmanin and its molecular weight was determined as 8608 Da by matrix-assisted laser desorption ionization/time-of-flight mass spectrometry (MALDI-TOF-MS). (c) 2006 John Wiley & Sons, Ltd.

  9. Evaluation of the phase ratio for three C18 high performance liquid chromatographic columns.

    PubMed

    Caiali, Edvin; David, Victor; Aboul-Enein, Hassan Y; Moldoveanu, Serban C

    2016-02-26

    For a chromatographic column, phase ratio Φ is defined as the ratio between the volume of the stationary phase Vst and the void volume of the column V0, and it is an important parameter characterizing the HPLC process. Although apparently simple, the evaluation of Φ presents difficulties because there is no sharp boundary between the mobile phase and the stationary phase. In addition, the boundary depends not only on the nature of the stationary phase, but also on the composition of the mobile phase. In spite of its importance, phase ratio is seldom reported for commercially available HPLC columns and the data typically provided by the vendors about the columns do not provide key information that would allow the calculation of Φ based on Vst and V0 values. A different procedure for the evaluation of Φ is based on the following formula: log k'j=a log Kow,j+log Φ, where k'j is the retention factor for a compound j that must be a hydrocarbon, Kow,j is the octanol/water partition coefficient, and a is a proportionality constant. Present study describes the experimental evaluation of Φ based on the measurement of k'j for the compounds in the homologous series between benzene and butylbenzene for three C18 columns: Gemini C18, Luna C18 both with 5 μm particles, and a Chromolith Performance RP-18. The evaluation was performed for two mobile phase systems at different proportions of methanol/water and acetonitrile/water. The octanol/water partition coefficients were obtained from the literature. The results obtained in the study provide further support for the new procedure for the evaluation of phase ratio. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Chromatographic column evaluation for the untargeted profiling of glucosinolates in cauliflower by means of ultra-high performance liquid chromatography coupled to high resolution mass spectrometry.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Montone, Carmela Maria; Piovesana, Susy; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2018-03-01

    The untargeted profiling is a promising approach for the characterization of secondary metabolites in biological matrices. Thanks to the recent rapid development of high-resolution mass spectrometry (HRMS) instrumentations, the number of applications by untargeted approaches for biological samples profiling has widely increased in the recent years. Despite the high potentialities of HRMS, however, a major issue in natural products analysis often arises in the upstream process of compounds separation. A separation technique is necessary to avoid phenomena such as signal suppression, and it is especially needed in the presence of isomeric metabolites, which are otherwise indistinguishable. Glucosinolates (GLSs), a group of secondary metabolites widely distributed among plants, resulted to be associated to the prevention of some serious diseases, such as cancer. This led to the development of several methods for the analysis of GLSs in vegetables tissues. The issue of GLSs chromatographic separation has been widely studied in the past because of the difficulty in the analysis of this highly polar and variable class of compounds. Several alternatives to reversed phase (RP) chromatography, sometimes not compatible with the coupling of liquid chromatography with mass spectrometry, have been tested for the analysis of intact GLSs. However, the availability of new stationary phases, in the last years, could allow the re-evaluation of RP chromatography for the analysis of intact GLSs. In this work, a thorough evaluation of four RP chromatographic columns for the analysis of GLSs in cauliflower (Brassica oleracea L. var. botrytis) extracts by an ultra-high performance liquid chromatographic system coupled via electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer is presented. The columns tested were the following: one column Luna Omega polar C 18 , one column Kinetex Biphenyl, one column Kinetex core-shell XB-C 18 , two columns Kinetex core-shell XB-C 18 . After a previous optimization of the extraction method, cauliflower extracts were analyzed testing four different mobile phases onto the four columns for a total of sixteen different chromatographic conditions. The chromatographic systems were evaluated based on the number of detected and tentatively identified GLSs. Luna Polar stationary phase resulted to be the most suitable for the analysis of GLSs compared to Kinetex XB and Kinetex Biphenyl columns stationary phase. However, two in series Kinetex XB columns increased the number of tentatively identified GLSs compared to one Kinetex XB, showing the importance of column length in the analysis of complex mixtures. The data obtained with the best chromatographic system were deeply analyzed by MS/MS investigation for the final identification. Fiflty-one GLSs were tentatively identified, 24 of which have never been identified in cauliflower. Finally the linearity of the analytes response over the analyzed range of concentration was checked, suggesting that the developed method is suitable for both qualitative and quantitative analysis of GLSs in phytochemical mixtures. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. [Determination of phthalate plasticizers in foods by high performance liquid chromatography with gel permeation chromatographic clean-up].

    PubMed

    Zhang, Chunyu; Wang, Hui; Zhang, Xiaohui; Ma, Zhongqiang; Deng, Wanmei; Hu, Ke; Ding, Mingyu

    2011-12-01

    A method of gel permeation chromatography-high performance liquid chromatography (GPC-HPLC) was established for the simultaneous determination of 5 main phthalate plasticizers in foods (edible oil, instant noodles, fried pastries, Saqima, etc.). The samples were extracted with petroleum ether in an ultrasonator, purified by a GPC column, and analyzed by HPLC. The chromatographic separation was achieved on a Labtech-C18 column (250 mm x 4.6 mm, 5 microm) using acetonitrile and water mixture as the mobile phases in a gradient elution mode. The developed method exhibited a linear correlation coefficient of more than 0.997 and the detection limits of 3.25 - 13.4 microg/L. The spike recoveries were between 70.4% and 113.6% with the relative standard deviations (RSDs, n = 3) of 0.3% - 5.8% at the spiked level of 50 mg/L. This method is simple, rapid and practical, and can be used for the simultaneous determination of PAEs in grease food samples.

  12. Pentaerythritol Tetranitrate (PETN) Surveillance by HPLC-MS: Instrumental Parameters Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, C A; Meissner, R

    Surveillance of PETN Homologs in the stockpile here at LLNL is currently carried out by high performance liquid chromatography (HPLC) with ultra violet (UV) detection. Identification of unknown chromatographic peaks with this detection scheme is severely limited. The design agency is aware of the limitations of this methodology and ordered this study to develop instrumental parameters for the use of a currently owned mass spectrometer (MS) as the detection system. The resulting procedure would be a ''drop-in'' replacement for the current surveillance method (ERD04-524). The addition of quadrupole mass spectrometry provides qualitative identification of PETN and its homologs (Petrin, DiPEHN,more » TriPEON, and TetraPEDN) using a LLNL generated database, while providing mass clues to the identity of unknown chromatographic peaks.« less

  13. Accessible silanol sites - beneficial for the RP-HPLC separation of constitutional and diastereomeric azaspirovesamicol isomers.

    PubMed

    Wenzel, Barbara; Fischer, Steffen; Brust, Peter; Steinbach, Jörg

    2010-12-10

    Different RP-HPLC columns (phenyl, conventional ODS, cross-linked C(18) and special end-capped C(8) and C(18) phases) were used to investigate the separation of four basic ionizable isomers. Using ACN/20mM NH(4)OAc aq., a separation was observed exclusively on RP columns with higher silanol activity at unusual high ACN concentration, indicating cation-exchange as main retention mechanism. Using MeOH/20mM NH(4)OAc aq., another separation at low MeOH concentrations was observed on both, RP columns with higher as well as RP columns with lower silanol activity, which is mainly based on hydrophobic interactions. The isomers were also separated on a bare silica column at higher MeOH content using NH(4)OAc. Since cation-exchange governs this retention, the elution order was different compared to the RP phases. A strong retention on the silica column was observed in ACN, which could be attributed to partition processes as additional retention mechanism. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. A single-run liquid chromatography mass spectrometry method to quantify neuroactive kynurenine pathway metabolites in rat plasma.

    PubMed

    Orsatti, Laura; Speziale, Roberto; Orsale, Maria Vittoria; Caretti, Fulvia; Veneziano, Maria; Zini, Matteo; Monteagudo, Edith; Lyons, Kathryn; Beconi, Maria; Chan, Kelvin; Herbst, Todd; Toledo-Sherman, Leticia; Munoz-Sanjuan, Ignacio; Bonelli, Fabio; Dominguez, Celia

    2015-03-25

    Neuroactive metabolites in the kynurenine pathway of tryptophan catabolism are associated with neurodegenerative disorders. Tryptophan is transported across the blood-brain barrier and converted via the kynurenine pathway to N-formyl-L-kynurenine, which is further degraded to L-kynurenine. This metabolite can then generate a group of metabolites called kynurenines, most of which have neuroactive properties. The association of tryptophan catabolic pathway alterations with various central nervous system (CNS) pathologies has raised interest in analytical methods to accurately quantify kynurenines in body fluids. We here describe a rapid and sensitive reverse-phase HPLC-MS/MS method to quantify L-kynurenine (KYN), kynurenic acid (KYNA), 3-hydroxy-L-kynurenine (3HK) and anthranilic acid (AA) in rat plasma. Our goal was to quantify these metabolites in a single run; given their different physico-chemical properties, major efforts were devoted to develop a chromatography suitable for all metabolites that involves plasma protein precipitation with acetonitrile followed by chromatographic separation by C18 RP chromatography, detected by electrospray mass spectrometry. Quantitation range was 0.098-100 ng/ml for 3HK, 9.8-20,000 ng/ml for KYN, 0.49-1000 ng/ml for KYNA and AA. The method was linear (r>0.9963) and validation parameters were within acceptance range (calibration standards and QC accuracy within ±30%). Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Simultaneous Liquid Chromatographic Determination of 10 Ultra-Violet Filters in Sunscreens.

    PubMed

    Wharton, Mary; Geary, Michael; O'Connor, Niamh; Curtin, Laura; Ketcher, Krystal

    2015-09-01

    A rapid HPLC method was developed for the simultaneous determination of 10 UV filters found in sunscreen. The following UV filters were analyzed in this method; 2-phenylbenzimidazole-5-sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, 4-methylbenzylidene camphor, octocrylene, ethylhexyl dimethyl 4-aminobenzoic acid, ethylhexyl methoxycinnamate, butyl methoxydibenzoylmethane, ethylhexyl salicylate and homosalate. The method was developed on two columns; a Thermo Hypersil C18 BDS, 3 µm column (4.6 × 100 mm) and a Chromolith RP-18e Monolithic column (4.6 × 100 mm). The same mobile phase of ethanol and 1% acetic acid (70:30, v/v) was employed for both columns. The separation of the 10 UV filters was carried out successfully on both columns; the optimal resolution was obtained on the Thermo Scientific Hypersil column in a time frame of 7 min. An isocratic elution utilizing ethanol and acetic acid (70:30, v/v) at a temperature of 35°C was employed. The method was applied to a number of commercial samples of sunscreen and lotions and was validated according to International Conference on Harmonisation guidelines for selectivity, linearity, accuracy, precision and robustness. A comparison of the performances of both columns was also carried out. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A Validated Stability Indicating RP-HPLC Method for the Determination of Emtricitabine, Tenofovir Disoproxil Fumarate, Elvitegravir and Cobicistat in Pharmaceutical Dosage Form

    PubMed Central

    Runja, Chinnalalaiah; Ravi Kumar, Pigili; Avanapu, Srinivasa Rao

    2016-01-01

    A new simple, rapid stability indicating assay method has been developed and validated for the determination of emtricitabine, tenofovir disoproxil fumarate, elvitegravir and cobicistat using reverse-phase high-performance liquid chromatography in their pharmaceutical dosage form. The chromatographic separation was performed on an ODS column (250 × 4.6 mm, 5 µm) using mobile phase A (potassium dihydrogen orthophosphate, pH adjusted to 2.5) and mobile phase B (acetonitrile) in the ratio of 55:45% v/v at a flow rate of 1 mL/min. The analytes were detected at 250 nm. The method was found to be linear in the concentration range of 2–12 µg/mL for EMT, 3–18 µg/mL for TNDF, 1.5–9 µg/mL for ELV and COB, with the coefficient value (R2) of >0.9990. The accuracy was measured via recovery studies and found to be acceptable, and the percentage recoveries were found in the range of 99.93–100.08 ± 0.5%. Forced degradation studies were also conducted, and the drugs were subjected to various stress conditions such as acid hydrolysis, base hydrolysis, oxidative, photolytic and thermal degradation. The proposed method was successfully validated and applied for the quantitative estimation of these drugs in both bulk and tablet dosage forms. PMID:26865655

  17. Stability-indicating RP-HPLC Method for the Simultaneous Determination of Sitagliptin and Simvastatin in Tablets

    PubMed Central

    Ramalingam, P.; Bhaskar, V. Udaya; Reddy, Y. Padmanabha; Kumar, K. Vinod

    2014-01-01

    A new stability-indicating high-performance liquid chromatographic method for simultaneous analysis of sitagliptin and simvastatin in pharmaceutical dosage form was developed and validated. The mobile phase consisted of methanol and water (70:30, v/v) with 0.2 % of n-heptane sulfonic acid adjusted to pH 3.0 with ortho phosphoric acid was used. Retentions of sitagliptin and simvastatin were 4.3 min and 30.4 min, respectively with a flow rate of 1 ml/min on C8 (Qualisil BDS, 250×4.6 mm, 5 μ). Eluents were detected at 253 nm using photodiode diode array detector. The linear regression analysis data for the linearity plot showed correlation coefficient values of 0.9998 and 0.9993 for sitagliptin and simvastatin, with respective concentration ranges of 20-150 μg/ml and 8-60 μg/ml. The relative standard deviation for inter-day precision was lower than 2.0%. The assay of sitagliptin and simvastatin was determined in tablet dosage form was found to be within limits. Both drugs were subjected to a variety of stress conditions such as acidic, basic, oxidation, photolytic, neutral and thermal stress in order to achieve adequate degradation. Results revealed that considerable degradation was found in all stress conditions except oxidative degradations. The method has proven specificity for stability indicating assay method. PMID:25425754

  18. Application of the artificial neural network in quantitative structure-gradient elution retention relationship of phenylthiocarbamyl amino acids derivatives.

    PubMed

    Tham, S Y; Agatonovic-Kustrin, S

    2002-05-15

    Quantitative structure-retention relationship(QSRR) method was used to model reversed-phase high-performance liquid chromatography (RP-HPLC) separation of 18 selected amino acids. Retention data for phenylthiocarbamyl (PTC) amino acids derivatives were obtained using gradient elution on ODS column with mobile phase of varying acetonitrile, acetate buffer and containing 0.5 ml/l of triethylamine (TEA). Molecular structure of each amino acid was encoded with 36 calculated molecular descriptors. The correlation between the molecular descriptors and the retention time of the compounds in the calibration set was established using the genetic neural network method. A genetic algorithm (GA) was used to select important molecular descriptors and supervised artificial neural network (ANN) was used to correlate mobile phase composition and selected descriptors with the experimentally derived retention times. Retention time values were used as the network's output and calculated molecular descriptors and mobile phase composition as the inputs. The best model with five input descriptors was chosen, and the significance of the selected descriptors for amino acid separation was examined. Results confirmed the dominant role of the organic modifier in such chromatographic systems in addition to lipophilicity (log P) and molecular size and shape (topological indices) of investigated solutes.

  19. Development and validation of a stability-indicating RP-HPLC-FLD method for determination of 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol; A novel drug candidate.

    PubMed

    Shehzadi, Naureen; Hussain, Khalid; Islam, Muhammad; Bukhari, Nadeem Irfan; Asif, Noman; Khan, Muhammad Tanveer; Salman, Muhammad; Qamar, Shaista; Parveen, Sajida; Zahid, Fakhra; Shah, Arshad Ali; Bilal, Abida; Abbasi, Muhammad Athar; Siddiqui, Sabahat Zahra; Rehman, Azizur

    2018-03-01

    The present study describes the development and validation of a simple high performance liquid chromatographic method for the determination of a novel drug candidate, 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol. The stability-indicating capacity of the method was evaluated by subjecting the compound's solution to hydrolytic, oxidative, photolytic, transition metal- and thermal- stress. The chromatographic separation was achieved over a C18 column (Promosil, 5 µm, 4.60 × 250 mm), maintained at 25°C, using an isocratic mobile phase comprising a mixture of acetonitrile and acidified water of pH 2.67 (1:1, v/v), at a flow rate of 1.00 mL/min and detection using a fluorescent light detector (excitation at 250 nm and emission at 410 nm). The Beer's law was followed over the concentration range 2.50-50.00 μg/ml. The recovery (98.56-100.19%, SD <5%), intraday accuracy and precision (97.31-100.81%, RSD <5%), inter-day accuracy and precision (97.50-100.75%, RSD <5%) and intermediate accuracy and precision (98.10-99.91%, RSD <5%) indicated that the method was reliable, repeatable, reproducible and rugged. The resolution and selectivity factors of the compound's peak from the nearest resolving peak, particularly in case of dry heat and copper metal stress, were found to be greater than 2 and 1, respectively, which indicated specificity and selectivity. The compound was extensively decomposed in alkaline-hydrolytic, oxidative, metal- and dry heat- stress. However, the compound in acidic and neutral conditions was resistant to photolysis. The results of the present study indicate that the developed method is specific, selective, sensitive and suitable, hence, may be used for quality control, stability testing and preformulation studies.

  20. High-Performance Liquid Chromatography (HPLC)-Based Detection and Quantitation of Cellular c-di-GMP.

    PubMed

    Petrova, Olga E; Sauer, Karin

    2017-01-01

    The modulation of c-di-GMP levels plays a vital role in the regulation of various processes in a wide array of bacterial species. Thus, investigation of c-di-GMP regulation requires reliable methods for the assessment of c-di-GMP levels and turnover. Reversed-phase high-performance liquid chromatography (RP-HPLC) analysis has become a commonly used approach to accomplish these goals. The following describes the extraction and HPLC-based detection and quantification of c-di-GMP from Pseudomonas aeruginosa samples, a procedure that is amenable to modifications for the analysis of c-di-GMP in other bacterial species.

  1. [HPLC fingerprint chromatogram analysis of some Taraxacum in Henan province].

    PubMed

    Li, Xi-Feng; Shi, Hui-Min; Xu, Min; Meng, Lu

    2008-10-01

    To analyze the HPLC fingerprint chromatogram of some Taraxacum in Henan. Samples of different species, producing areas, harvest seasons and medicinal parts were determined by RP-HPLC. The chromatogram was evaluated by software of evaluating similarity. The components of different species in Taraxacum were the same and could be substituted for each other. The contents of coffeic acid and chlorogenic acid in different producing areas were very different,which in fecund soil was better. The period of flowering and fruiting in Spring was the best gather period, and the components in different parts were different. The quality of medicinal materal within Taraxacum should be controlled better by this method.

  2. Comparative evaluation of ICP sample introduction systems to be used in the metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS.

    PubMed

    Klencsár, Balázs; Sánchez, Carlos; Balcaen, Lieve; Todolí, José; Lynen, Frederic; Vanhaecke, Frank

    2018-05-10

    A systematic evaluation of four different ICP sample introduction systems to be used in the context of metabolite profiling of chlorine-containing pharmaceuticals via HPLC-ICP-MS was carried out using diclofenac and its major metabolite, 4'-hydroxy-diclofenac, as model compounds. The strict requirements for GMP validation of chromatographic methods in the pharmaceutical industry were adhered to in this context. The final aim of this investigation is an extension of the applicability and validatability of HPLC-ICP-MS in the field of pharmaceutical R&D. Five different gradient programmes were tested while the baseline peak width (w b ), peak capacity (P), USP tailing factor (A s ) and USP signal-to-noise ratio (USP S/N) were determined as major indicators of the chromatographic performance and the values obtained were compared to the corresponding FDA recommendations (if applicable). Four different ICP-MS sample introductions systems were investigated involving two units typically working at higher flow rates (∼1.0 mL min -1 ) and another two systems working at lower flow rates (∼0.1 mL min -1 ). Optimal conditions with potential for applicability under GMP conditions were found at a mobile phase flow rate of 1.0 mL min -1 by using a pneumatic micro-flow LC nebulizer mounted onto a Peltier-cooled cyclonic spray chamber cooled to -1 °C for sample introduction. Under these conditions, HPLC-ICP-MS provided a chromatographic performance similar to that of HPLC with UV detection. The peak shape (USP tailing factor = 1.1-1.4) was significantly improved compared to that obtained with the Peltier-cooled Scott-type spray chamber. Two alternative sample introduction systems - a POINT ® and a High-Temperature Torch-Integrated Sample Introduction System (hTISIS) - were also tested at a flow rate of 0.1 mL min -1 using a chromatographic column with 1.0 mm ID. Although these systems allowed the peak shape to be improved compared to that obtained with the traditional Scott-type spray chamber, the limits of detection and of quantification achievable were strongly compromised due to the significantly lower sensitivity observed for Cl. In addition to a comparison of the aforementioned sample introduction systems, also the effect of spray chamber temperature was evaluated and it was demonstrated that proper temperature control plays an essential role in the optimization of HPLC-ICP-MS methods. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Determination of salicylic acid by HPLC in plasma and saliva from children with juvenile chronic arthritis.

    PubMed

    Legaz, M E; Acitores, E; Valverde, F

    1992-12-01

    A high performance liquid chromatography (HPLC) method has been developed for measuring salicylic acid in the plasma and saliva of children with juvenile chronic arthritis (JCA). Samples were extracted with diethyl ether and, after drying, redissolved in methanol to be chromatographed. Quantitation of salicylic acid was performed by reverse phase HPLC on a spherisorb ODS-2 column, using methanol: water: acetic acid as mobile phase. Phenolic was monitored by absorbance at 237 nm. Linearity between the amount of mass injected and the response in the detector was determined. This method was applied to compare concentrations of salivary and plasma salicylic acid. The method also permitted the quantitation of salivary salicylate as a non-invasive, indirect method for monitoring the concentration of plasma salicylate in patients with JCA.

  4. Comparison of monolithic and microparticulate columns for reversed-phase liquid chromatography of tryptic digests of industrial enzymes in cleaning products.

    PubMed

    Beneito-Cambra, M; Herrero-Martínez, J M; Ramis-Ramos, G; Lindner, W; Lämmerhofer, M

    2011-10-14

    Enzymes of several classes used in the formulations of cleaning products were characterized by trypsin digestion followed by HPLC with UV detection. A polymeric monolithic column (ProSwift) was used to optimize the separation of both the intact enzymes and their tryptic digests. This column was adequate for the quality control of raw industrial enzyme concentrates. Then, monolithic and microparticulate columns were compared for peptide analysis. Under optimized conditions, the analysis of tryptic digests of enzymes of different classes commonly used in the formulation of cleaning products was carried out. Number of peaks, peak capacity and global resolution were obtained in order to evaluate the chromatographic performance of each column. Particulate shell-core C18 columns (Kinetex, 2.6 μm) showed the best performance, followed by a silica monolithic column (Chromolith RP-18e) and the conventional C18 packings (Gemini, 5 μm or 3 μm). A polymeric monolithic column (ProSwift) gave the worst performances. The proposed method was satisfactorily applied to the characterization of the enzymes present in spiked detergent bases and commercial cleaners. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. RP-HPLC determination of water-soluble vitamins in honey.

    PubMed

    Ciulu, Marco; Solinas, Silvia; Floris, Ignazio; Panzanelli, Angelo; Pilo, Maria I; Piu, Paola C; Spano, Nadia; Sanna, Gavino

    2011-01-15

    The assessment and validation of reliable analytical methods for the determination of vitamins in sugar-based matrices (e.g. honey) are still scarcely explored fields of research. This study proposes and fully validates a simple and fast RP-HPLC method for the simultaneous determination of five water-soluble vitamins (vitamin B(2), riboflavin; vitamin B(3), nicotinic acid; vitamin B(5), pantothenic acid; vitamin B(9), folic acid; and vitamin C, ascorbic acid) in honey. The method provides low detection and quantification limits, very good linearity in a large concentration interval, very good precision, and the absence of any bias. It has been successfully applied to 28 honey samples (mainly from Sardinia, Italy) of 12 different botanical origins. While the overall amount of the analytes in the samples is quite low (always below 40 mg kg(-1)), we have observed a marked dependence of some of their concentrations (i.e. vitamin B(3) and vitamin B(5)) and the botanical origin of the honey. This insight might lead to important characterization features for this food item. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. [Determination of triterpenoic acids in fruits of Ziziphus jujuba using HPLC-MS with polymeric ODS column].

    PubMed

    Zhang, Yong; Zhou, An; Xie, Xiao-Mei

    2013-03-01

    A simple and sensitive method has been developed to simultaneously determine betunilic acid, oleanolic acid and ursolic acid in the fruits of Ziziphus jujuba from different regions by HPLC-MS. This HPLC assay was performed on PAH polymeric C18 bonded stationary phase column with mobile phase contained acetonitrile-water (90: 10) and with negative ESI detection mode. The developed approach was characterized by short time consumption for chromatographic separation, high sensitivity and good reliability so as to meet the requirements for rapid analysis of large-batch fruits of Z. jujuba from different habitats.

  7. Achiral-chiral two-dimensional chromatography of free amino acids in milk: A promising tool for detecting different levels of mastitis in cows.

    PubMed

    Ianni, Federica; Sardella, Roccaldo; Lisanti, Antonella; Gioiello, Antimo; Cenci Goga, Beniamino Terzo; Lindner, Wolfgang; Natalini, Benedetto

    2015-12-10

    In two-dimensional HPLC (2D-HPLC) "heart-cut" applications, two columns are connected in series via a switching valve and volume fractions from the "primary" column are re-injected on the "secondary" column. The heart-cut 2D-HPLC system here described was implemented by connecting a reversed-phase (RP) column (first dimension) to a chiral column (second dimension) containing a quinidine-based chiral stationary phase. The system was used to evaluate the change in the enantiomeric excess value of dansylated (Dns) amino acids (AAs) in milk samples from two cows with different "California Mastitis Test" scores: negative test for sample 1, positive for sample 2. Apart from the co-elution of Dns-Arg/Dns-Gly and the reduced chemoselectivity for Dns-Leu/Dns-allo-Ile, the optimized achiral RP method distinguished the remaining standard Dns-AAs. Dns-AAs were identified in the chromatograms of the real samples, and in higher concentration Dns-Ala, Dns-Arg, Dns-Asp, Dns-Glu, Dns-Ile, Dns-Leu, Dns-Phe and Dns-Val. Except Dns-Arg, the chiral column enabled the RP enantioseparation of all the other compounds (α and RS values up to 1.65 and 8.63, respectively, for Dns-Phe). In sample 2, the amounts of Dns-d-AAs were rather elevated, in particular for Dns-Ala and Dns-Asp. Instead, for sample 1, D-isomers were detected for Dns-Ala, Dns-Glu and Dns-Leu. The proposed 2D-HPLC method could be useful for the identification of clinical mastitis difficult to be diagnosed. Moreover, the eventual progressive reduction of D-AAs levels with the degree of sub-clinical mastitis could allow the building of mathematical models to use for the diagnosis of early stages of mastitis. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. [Studies on HPLC fingerprint chromatogram of Folium Fici Microcarpa].

    PubMed

    Fang, Zhi-Jian; Dai, Zhen; Li, Shu-Yuan

    2008-10-01

    To establish a sensitive and specific method for quality control of Folium Fici Microcarpa, HPLC method was applied for studies on the fingerprint chromatogram of Folium Fici Microcarpa. Isovitexin was used as reference substance to evaluate the chromatogram of 10 samples from different regions and 12 samples collected in different months. The result revealed that all the chromatographic peaks were seperated efficiently. There were 17 common peaks showed in the fingerprint chromatogram. The method of fingerprint chromatogram with characteristic and specificity will be used to identify the quality and evaluate different origins and collection period of Folium Fici Microcarpa.

  9. Pharmacognostic Screening of Piper trichostachyon Fruits and its Comparative Analysis with Piper nigrum Using Chromatographic Techniques

    PubMed Central

    Upadhya, Vinayak; Pai, Sandeep R.; Ankad, Gireesh M.; Hegde, Harsha V.

    2016-01-01

    Background: Piper trichostachyon is a wild, endemic Piper species from Western Ghats of India. The folklore healers of Belagavi region use this plant, similar to Piper nigrum. Aims: The present study investigates the comparison between P. nigrum and P. trichostachyon using pharmacognostic parameters. Materials and Methods: Pharmacognostic evaluation was carried out in terms of morphological, microscopic characters, and phytochemical analysis using standard methods. Comparative physicochemical analysis between P. trichostachyon and P. nigrum was also carried out through estimation of micro-macro nutrients, high-performance thin layer chromatography (HPTLC) investigation and using piperine as a marker compound for reversed phase-ultra flow liquid chromatographic (RP-UFLC) technique. Results: P. trichostachyon grows in the forests, and the fruits are morphologically similar to P. nigrum fruits, so the name in Kannada “Kaadu Kalu menasu” (wild/forest black pepper). The microscopy revealed the presence of stone cells, starch grains, oil cells and globules, beaker cells, and yellowish brown pigment layer, parenchymatous cells. The presence of alkaloids, oil, and tannins were observed in P. trichostachyon fruits. The HPTLC studies visibly indicated differences among two species with 12 peaks and varied banding pattern. RP-UFLC results showed less amount of piperine in P. trichostachyon (0.05 ± 0.002 mg/g) than in P. nigrum (16.14 ± 0.807 mg/g). Conclusion: The study reports on pharmacognostic parameters of P. trichostachyon for the 1st time and will be useful for the identification and authentication. The comparative HPTLC and RP-UFLC studies resolve the differentiation impasse among two species. However, further biological efficacy studies are required to establish its use in traditional medicine. SUMMARY Piper trichostachyon grows in the forests, and the fruits are morphologically similar to Piper nigrum fruitsThe microscopy of P. trichostachyon revealed the presence of stone cells, starch grains, oil cells and globules, beaker cells and yellowish brown pigment layer, parenchymatous cellsThe high-performance thin layer chromatography studies visibly indicated differences among two species with varied banding patternReversed phase-ultra flow liquid chromatographic results showed less amount of piperine in P. trichostachyon than in P. nigrum. Abbreviation used: HPTLC: High Performance Thin Layer Chromatography, RP-UFLC: Reversed phase-ultra flow liquid chromatographic analysis, DST: Length of line, Maj: Length of large half axis for ellipse RDS - radius for circle, Rf: Retention Factor, TS: Transverse Section, TLC: Thin Layer Chromatography. PMID:27279700

  10. Determination of naltrexone and 6beta-naltrexol in human blood: comparison of high-performance liquid chromatography with spectrophotometric and tandem-mass-spectrometric detection.

    PubMed

    Brünen, Sonja; Krüger, Ralf; Finger, Susann; Korf, Felix; Kiefer, Falk; Wiedemann, Klaus; Lackner, Karl J; Hiemke, Christoph

    2010-02-01

    We present data for a comparison of a liquid-chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) and a high-performance liquid-chromatographic method with column switching and UV spectrophotometric detection. The two methods were developed for determination of naltrexone and 6beta-naltrexol in blood serum or plasma aiming to be used for therapeutic drug monitoring to guide the treatment of patients with naltrexone. For the high-performance liquid chromatography (HPLC)/UV detection, online sample cleanup was conducted on Perfect Bond C(18) material with 2% (vol/vol) acetonitrile in deionized water. Drugs were separated on a C(18) column using 11.5% (vol/vol) acetonitrile and 0.4% (vol/vol) N,N,N,N-tetramethylethylenediamine within 20 min. LC-MS/MS used naltrexone-d (3) and 6beta-naltrexol-d (4) as internal standards. After protein precipitation, the chromatographic separation was performed on a C(18) column by applying a methanol gradient (5-100%, vol/vol) with 0.1% formic acid over 9.5 min. The HPLC/UV method was found to be linear for concentrations ranging from 2 to 100 ng/ml, with a regression correlation coefficient of r (2) > 0.998 for naltrexone and 6beta-naltrexol. The limit of quantification was 2 ng/ml for naltrexone and 6beta-naltrexol. For the LC-MS/MS method the calibration curves were linear (r(2) > 0.999) from 0.5 to 200 ng/ml for both substances, and the limit of quantification was 0.5 ng/ml. The concentrations measured by the two methods correlated significantly for both substances (r(2) > 0.967; p < 0.001). Both methods could be used for therapeutic drug monitoring. The HPLC/UV method was advantageous regarding automatization and costs, whereas LC-MS/MS was superior with regard to sensitivity.

  11. Development and application of a validated HPLC method for the analysis of dissolution samples of levothyroxine sodium drug products.

    PubMed

    Collier, J W; Shah, R B; Bryant, A R; Habib, M J; Khan, M A; Faustino, P J

    2011-02-20

    A rapid, selective, and sensitive gradient HPLC method was developed for the analysis of dissolution samples of levothyroxine sodium tablets. Current USP methodology for levothyroxine (L-T(4)) was not adequate to resolve co-elutants from a variety of levothyroxine drug product formulations. The USP method for analyzing dissolution samples of the drug product has shown significant intra- and inter-day variability. The sources of method variability include chromatographic interferences introduced by the dissolution media and the formulation excipients. In the present work, chromatographic separation of levothyroxine was achieved on an Agilent 1100 Series HPLC with a Waters Nova-pak column (250 mm × 3.9 mm) using a 0.01 M phosphate buffer (pH 3.0)-methanol (55:45, v/v) in a gradient elution mobile phase at a flow rate of 1.0 mL/min and detection UV wavelength of 225 nm. The injection volume was 800 μL and the column temperature was maintained at 28°C. The method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, specificity, linearity, and analytical range. The standard curve was found to have a linear relationship (r(2)>0.99) over the analytical range of 0.08-0.8 μg/mL. Accuracy ranged from 90 to 110% for low quality control (QC) standards and 95 to 105% for medium and high QC standards. Precision was <2% at all QC levels. The method was found to be accurate, precise, selective, and linear for L-T(4) over the analytical range. The HPLC method was successfully applied to the analysis of dissolution samples of marketed levothyroxine sodium tablets. Published by Elsevier B.V.

  12. Development and application of a validated HPLC method for the analysis of dissolution samples of levothyroxine sodium drug products

    PubMed Central

    Collier, J.W.; Shah, R.B.; Bryant, A.R.; Habib, M.J.; Khan, M.A.; Faustino, P.J.

    2011-01-01

    A rapid, selective, and sensitive gradient HPLC method was developed for the analysis of dissolution samples of levothyroxine sodium tablets. Current USP methodology for levothyroxine (l-T4) was not adequate to resolve co-elutants from a variety of levothyroxine drug product formulations. The USP method for analyzing dissolution samples of the drug product has shown significant intra- and inter-day variability. The sources of method variability include chromatographic interferences introduced by the dissolution media and the formulation excipients. In the present work, chromatographic separation of levothyroxine was achieved on an Agilent 1100 Series HPLC with a Waters Nova-pak column (250mm × 3.9mm) using a 0.01 M phosphate buffer (pH 3.0)–methanol (55:45, v/v) in a gradient elution mobile phase at a flow rate of 1.0 mL/min and detection UV wavelength of 225 nm. The injection volume was 800 µL and the column temperature was maintained at 28 °C. The method was validated according to USP Category I requirements. The validation characteristics included accuracy, precision, specificity, linearity, and analytical range. The standard curve was found to have a linear relationship (r2 > 0.99) over the analytical range of 0.08–0.8 µg/mL. Accuracy ranged from 90 to 110% for low quality control (QC) standards and 95 to 105% for medium and high QC standards. Precision was <2% at all QC levels. The method was found to be accurate, precise, selective, and linear for l-T4 over the analytical range. The HPLC method was successfully applied to the analysis of dissolution samples of marketed levothyroxine sodium tablets. PMID:20947276

  13. Steroids

    NASA Astrophysics Data System (ADS)

    Frey, Felix J.; Frey, Brigitte M.; Benet, Leslie Z.

    If a radioimmunoassay, a protein binding method, or a colorimetric assay for the assessment of a steroid level is replaced by high performance liquid chromatography (HPLC), the cost for the determination of a steroid level increases at least initially because one must acquire the new HPLC equipment. Therefore, if an older method provides the same results as the new, "advanced" HPLC method, the only advantage resulting from the introduction of a high performance chromatographic assay is that gained by the manufacturer in terms of greater sales. Thus, justification for the assessment of steroids by HPLC is only obtained if the quality and/or quantity of information gained is significantly increased as compared to that provided by the conventional methods. But this evidential relation, that more and better information justifies a higher price in any case, is no longer true in health care, with the birth some years ago of the categoric imperative for the reduction of costs in the medical sector. That is, each new technology introduced for health maintenance should demonstrate at least a stabilizing impact on total medical expenditures. Therefore, after reviewing the presently available HPLC methods for the clinically important steroids, we will consider whether HPLC analyses for these steroids can be recommended without violating this vox populi.

  14. Understanding Single-Stranded Telomere End Binding by an Essential Protein

    DTIC Science & Technology

    2000-08-01

    BioPharma Inc., 1885 33rd Street, Boulder, CO 80301 Traditional sequential medicinal chemistry methods have been augmented by combinatorial synthesis...on the same wells that were being analyzed in parallel by RP-HPLC/UV for purity. The sampling protocol for purity determination at Array BioPharma is

  15. Validated Chromatographic Methods for the Analysis of Two Binary Mixtures Containing Pyridoxine Hydrochloride.

    PubMed

    Habib, Neven M; Abdelrahman, Maha M; Abdelwhab, Nada S; Ali, Nourudin W

    2017-03-01

    Accurate and precise TLC-densitometric and HPLC-diode-array detector (DAD) methods have been developed and validated to resolve two binary mixtures containing pyridoxine hydrochloride (PYH) with either cyclizine hydrochloride (CYH) or meclizine hydrochloride (MEH). In the developed TLC-densitometric method, chromatographic separation of the three studied drugs was carried out on silica gel 60 F254 plates using a developing system containing methylene chloride + acetone + methanol (7 + 1 + 0.5, v/v/v) scanning separated bands at 220 nm. Beer-Lambert law was obeyed in the ranges of 0.2-5, 0.2-4, and 0.2-4 µg/band for PYH, CYH, and MEH, respectively. On the other hand, the developed HPLC-DAD method depended on chromatographic separation on a Zorbax Eclipse C18 column using methanol-KH2PO4 (0.05 M; 90 + 10, v/v; pH 5, with H3PO4 and KOH) as the mobile phase, a flow rate of 1 mL/min, and UV scanning at 220 nm. A linear relationship was obtained between the integrated peak area and the concentration in the ranges of 10-50, 10-50, and 7-50 µg/mL for PYH, CYH, and MEH, respectively. The proposed methods were successfully applied for the determination of the cited drugs in their pharmaceutical formulations. Statistical comparison with the reported methods using Student's t- and F-tests found there were no significant differences between the proposed and reported methods for accuracy and precision.

  16. Physical-chemical and biological characterization of different preparations of equine chorionic gonadotropin

    PubMed Central

    Natal, Fabio Luis Nogueira; Ribela, Maria Teresa Carvalho Pinto; de Almeida, Beatriz Elane; de Oliveira, João Ezequiel; Bartolini, Paolo

    2016-01-01

    Ovarian stimulation with commercial preparations of equine chorionic gonadotropin (eCG) produces extremely variable responses in domestic animals, ranging from excessive stimulation to practically no stimulation, when applied on the basis of their declared unitage. This study was conducted to analyze four commercial preparations from different manufacturers via reversed-phase HPLC (RP-HPLC) in comparison with a reference preparation and an official International Standard from the World Health Organization. The peaks obtained by this qualitative and quantitative physical–chemical analysis were compared using an in vivo bioassay based on the ovarian weight gain of prepubertal female rats. The RP-HPLC data showed one or two peaks close to a main peak (tR = 27.9 min), which were related to the in vivo bioactivity. Commercial preparations that have this altered peak showed very little or no in vivo activity, as demonstrated by rat ovarian weight and in peripubertal gilts induced to ovulate. Overall, these findings indicate that RP-HPLC can be a rapid and reliable tool to reveal changes in the physicochemical profile of commercial eCG that is apparently related to decreased biological activity of this hormone. PMID:27297410

  17. Microcystin in cyanobacterial blooms in a Chilean lake.

    PubMed

    Campos, V; Cantarero, S; Urrutia, H; Heinze, R; Wirsing, B; Neumann, U; Weckesser, J

    1999-05-01

    Cyanobacterial blooms dominated by Microcystis sp. occurred in lake Rocuant ("marisma", near Concepción/Chile) in February 1995 and 1996. In the bloom samples collected in both years the hepatotoxin microcystin was detected by RP-HPLC in both samples and in the sample of 1995 also by a toxicity assay using primary rat hepatocytes. In the bloom of 1995, the microcystin content of the dry bloom biomass was determined to be 130 micrograms/g on the basis of the RP-HPLC peak area and 800 micrograms/g on the basis of the rat hepatotoxicity assay, respectively. In the bloom of 1996, RP-HPLC analysis revealed a microcystin content of 8.13 micrograms/g bloom material dry weight. In this year no hepatotoxicity was measured using a concentration range up to 0.8 mg (d. w.) of bloom material per ml in the rat hepatotoxicity assay. This is the first report on the detection of microcystins in Chilean water bodies.

  18. Probabilistic classification method on multi wavelength chromatographic data for photosynthetic pigments identification

    NASA Astrophysics Data System (ADS)

    Prilianti, K. R.; Setiawan, Y.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2014-02-01

    Environmental and health problem caused by artificial colorant encourages the increasing usage of natural colorant nowadays. Natural colorant refers to the colorant that is derivate from living organism or minerals. Extensive research topic has been done to exploit these colorant, but recent data shows that only 0.5% of the wide range of plant pigments in the earth has been exhaustively used. Hence development of the pigment characterization technique is an important consideration. High-performance liquid chromatography (HPLC) is a widely used technique to separate pigments in a mixture and identify it. In former HPLC fingerprinting, pigment characterization was based on a single chromatogram from a fixed wavelength (one dimensional) and discard the information contained at other wavelength. Therefore, two dimensional fingerprints have been proposed to use more chromatographic information. Unfortunately this method leads to the data processing problem due to the size of its data matrix. The other common problem in the chromatogram analysis is the subjectivity of the researcher in recognizing the chromatogram pattern. In this research an automated analysis method of the multi wavelength chromatographic data was proposed. Principal component analysis (PCA) was used to compress the data matrix and Maximum Likelihood (ML) classification was applied to identify the chromatogram pattern of the existing pigments in a mixture. Three photosynthetic pigments were selected to show the proposed method. Those pigments are β-carotene, fucoxanthin and zeaxanthin. The result suggests that the method could well inform the existence of the pigments in a particular mixture. A simple computer application was also developed to facilitate real time analysis. Input of the application is multi wavelength chromatographic data matrix and the output is information about the existence of the three pigments.

  19. Characterization of bonded stationary phase performance as a function of qualitative and quantitative chromatographic factors in chaotropic chromatography with risperidone and its impurities as model substances.

    PubMed

    Čolović, Jelena; Rmandić, Milena; Malenović, Anđelija

    2018-05-17

    Numerous stationary phases have been developed with the aim to provide desired performances during chromatographic analysis of the basic solutes in their protonated form. In this work, the procedure for the characterization of bonded stationary phase performance, when both qualitative and quantitative chromatographic factors were varied in chaotropic chromatography, was proposed. Risperidone and its three impurities were selected as model substances, while acetonitrile content in the mobile phase (20-30%), the pH of the aqueous phase (3.00-5.00), the content of chaotropic agents in the aqueous phase (10-100 mM), type of chaotropic agent (NaClO 4 , CF 3 COONa), and stationary phase type (Zorbax Eclipse XDB, Zorbax Extend) were studied as chromatographic factors. The proposed procedure implies the combination of D-optimal experimental design, indirect modeling, and polynomial-modified Gaussian model, while grid point search method was selected for the final choice of the experimental conditions which lead to the best possible stationary phase performance for basic solutes. Good agreement between experimentally obtained chromatogram and simulated chromatogram for chosen experimental conditions (25% acetonitrile, 75 mM of NaClO 4 , pH 4.00 on Zorbax Eclipse XDB column) confirmed the applicability of the proposed procedure. The additional point was selected for the verification of proposed procedure ability to distinguish changes in solutes' elution order. Simulated chromatogram for 21.5% acetonitrile, 85 mM of NaClO 4 , pH 5.00 on Zorbax Eclipse XDB column was in line with experimental data. Furthermore, the values of left and right peak half-widths obtained from indirect modeling were used in order to evaluate performances of differently modified stationary phases applying a half-width plots approach. The results from half-width plot approach as well as from the proposed procedure indicate higher efficiency and better separation performance of the stationary phase extra densely bonded and double end-capped with trimethylsilyl group than the stationary phase with the combination of end-capping and bidentate silane bonding for chromatographic analysis of basic solutes in RP-HPLC systems with chaotropic agents. Graphical abstract ᅟ.

  20. A rapid reversed-phase thin layer chromatographic protocol for detection of adulteration in ghee (clarified milk fat) with vegetable oils.

    PubMed

    Rani, Anupama; Sharma, Vivek; Arora, Sumit; Lal, Darshan; Kumar, Anil

    2015-04-01

    Detection of milk fat adulteration with foreign fats/oils continues to be a challenge for the dairy industry as well as food testing laboratories, especially in the present scenario of rampant adulteration using the scientific knowledge by unscrupulous persons involved in the trade. In the present investigation a rapid reversed-phase thin layer chromatographic (RP-TLC) protocol was standardized to ascertain the purity of milk fat. RP-TLC protocol did not show any false positive results in the genuine ghee (clarified butter fat) samples of known origin. Adulteration of ghee with coconut oil up to 7. 5 %, soybean oil, sunflower oil and groundnut oil up to 1 %, while, designer oil up to 2 % level could be detected using the standardized RP-TLC protocol. The protocol standardized is rapid and convenient to use.

  1. Quality evaluation of Desmodium styracifolium using high-performance liquid chromatography with photodiode array detection and electrospray ionisation tandem mass spectrometry.

    PubMed

    Zhou, Chan; Luo, Jian-Guang; Kong, Ling-Yi

    2012-01-01

    Desmodium styracifolium, with C-flavone glycosides as main pharmacological effective compounds, is a popular Chinese medicinal herb and has been used to treat urination disturbance, urolithiasis, edema and jaundice. However, few systematic methods have been reported on the quality control of this natural herb. To develop a method for control the quality of D. styracifolium by combining chromatographic fingerprints and major constituent quantification. Separations were performed on an Ultimate XB-C-18 column by gradient elution using acetonitrile and 0.1% aqueous formic acid. Analytes were identified by HPLC coupled with electrospray ionisation mass spectrometry experiments. Twenty common peaks in chromatographic fingerprints were first identified among 15 batches of D. styracifolium from various regions. On basis of this, a HPLC-PAD method was established to simultaneously quantify five major constituents, which was validated for limit of qualification, linearity and interday variation of precision and accuracy. The assay developed could be considered as a suitable quality control method of D. styracifolium. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Pharmacognostic Screening of Piper trichostachyon Fruits and its Comparative Analysis with Piper nigrum Using Chromatographic Techniques.

    PubMed

    Upadhya, Vinayak; Pai, Sandeep R; Ankad, Gireesh M; Hegde, Harsha V

    2016-05-01

    Piper trichostachyon is a wild, endemic Piper species from Western Ghats of India. The folklore healers of Belagavi region use this plant, similar to Piper nigrum. The present study investigates the comparison between P. nigrum and P. trichostachyon using pharmacognostic parameters. Pharmacognostic evaluation was carried out in terms of morphological, microscopic characters, and phytochemical analysis using standard methods. Comparative physicochemical analysis between P. trichostachyon and P. nigrum was also carried out through estimation of micro-macro nutrients, high-performance thin layer chromatography (HPTLC) investigation and using piperine as a marker compound for reversed phase-ultra flow liquid chromatographic (RP-UFLC) technique. P. trichostachyon grows in the forests, and the fruits are morphologically similar to P. nigrum fruits, so the name in Kannada "Kaadu Kalu menasu" (wild/forest black pepper). The microscopy revealed the presence of stone cells, starch grains, oil cells and globules, beaker cells, and yellowish brown pigment layer, parenchymatous cells. The presence of alkaloids, oil, and tannins were observed in P. trichostachyon fruits. The HPTLC studies visibly indicated differences among two species with 12 peaks and varied banding pattern. RP-UFLC results showed less amount of piperine in P. trichostachyon (0.05 ± 0.002 mg/g) than in P. nigrum (16.14 ± 0.807 mg/g). The study reports on pharmacognostic parameters of P. trichostachyon for the 1(st) time and will be useful for the identification and authentication. The comparative HPTLC and RP-UFLC studies resolve the differentiation impasse among two species. However, further biological efficacy studies are required to establish its use in traditional medicine. Piper trichostachyon grows in the forests, and the fruits are morphologically similar to Piper nigrum fruitsThe microscopy of P. trichostachyon revealed the presence of stone cells, starch grains, oil cells and globules, beaker cells and yellowish brown pigment layer, parenchymatous cellsThe high-performance thin layer chromatography studies visibly indicated differences among two species with varied banding patternReversed phase-ultra flow liquid chromatographic results showed less amount of piperine in P. trichostachyon than in P. nigrum. Abbreviation used: HPTLC: High Performance Thin Layer Chromatography, RP-UFLC: Reversed phase-ultra flow liquid chromatographic analysis, DST: Length of line, Maj: Length of large half axis for ellipse RDS - radius for circle, Rf: Retention Factor, TS: Transverse Section, TLC: Thin Layer Chromatography.

  3. Simultaneous HPLC-F analysis of three recent antiepileptic drugs in human plasma.

    PubMed

    Mercolini, Laura; Mandrioli, Roberto; Amore, Mario; Raggi, Maria Augusta

    2010-09-21

    An original high-performance liquid chromatographic method with fluorescence detection is presented for the simultaneous determination of the three antiepileptic drugs gabapentin, vigabatrin and topiramate in human plasma. After pre-column derivatisation with dansyl chloride, the analytes were separated on a Hydro-RP column with a mobile phase composed of phosphate buffer (55%) and acetonitrile (45%) and detected at lambda(em)=500 nm, exciting at 300 nm. An original pre-treatment procedure on biological samples, based on solid-phase extraction with MCX cartridges for gabapentin and vigabatrin, and with Plexa cartridges for topiramate, gave high extraction yields (>91%), satisfactory precision (RSD<6.4%) and good selectivity. Linearity was found in the 0.2-50.0 microg mL(-1) range for gabapentin, in the 1.0-100.0 microg mL(-1) range for vigabatrin and in the 1.0-50.0 microg mL(-1) range for topiramate, with limits of detection (LODs) between 0.1 and 0.3 microg mL(-1). After validation, the method was successfully applied to some plasma samples from patients undergoing therapy with one or more of these drugs. Accuracy results were satisfactory (recovery >91%). Therefore, the method seems to be suitable for the therapeutic drug monitoring (TDM) of patients treated with gabapentin, vigabatrin and topiramate. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Simultaneous determination of chloramphenicol, dexamethasone and naphazoline in ternary and quaternary mixtures by RP-HPLC, derivative and wavelet transforms of UV ratio spectra

    NASA Astrophysics Data System (ADS)

    Hoang, Vu Dang; Hue, Nguyen Thu; Tho, Nguyen Huu; Nguyen, Hue Minh Thi

    2015-03-01

    The application of chemometrics-assisted UV spectrophotometry and RP-HPLC to the simultaneous determination of chloramphenicol, dexamethasone and naphazoline in ternary and quaternary mixtures is presented. The spectrophotometric procedure is based on the first-order derivative and wavelet transforms of ratio spectra using single, double and successive divisors. The ratio spectra were differentiated and smoothed using Savitzky-Golay filter; whereas wavelet transform realized with wavelet functions (i.e. db6, gaus5 and coif3) to obtain highest spectral recoveries. For the RP-HPLC procedure, the separation was achieved on a ZORBAX SB-C18 (150 × 4.6 mm; 5 μm) column at ambient temperature and the total run time was less than 7 min. A mixture of acetonitrile - 25 mM phosphate buffer pH 3 (27:73, v/v) was used as the mobile phase at a flow rate of 1.0 mL/min and the effluent monitored by measuring absorbance at 220 nm. Calibration graphs were established in the range 20-70 mg/L for chloramphenicol, 6-14 mg/L for dexamethasone and 3-8 mg/L for naphazoline (R2 > 0.990). The RP-HPLC and ratio spectra transformed by a combination of derivative-wavelet algorithms proved to be able to successfully determine all analytes in commercial eye drop formulations without sample matrix interference (mean percent recoveries, 97.4-104.3%).

  5. Determination of phenolic compounds derived from hydrolysable tannins in biological matrices by RP-HPLC.

    PubMed

    Díez, María Teresa; García del Moral, Pilar; Resines, José Antonio; Arín, María Jesús

    2008-08-01

    An RP-HPLC method for the determination of four phenolic compounds: gallic acid (GA), pyrogallol (PY), resorcinol (RE) and ellagic acid (EA), derived from hydrolysable tannins is reported. Separation was achieved on a SunFire C18 (250 x 4.6 mm id, 5 microm) column at 40 degrees C with gradient elution. UV detection at 280 nm was applied. The developed method was validated in terms of linearity, accuracy and precision. Satisfactory repeatability and between day precision were noticed with RSD values lower than 3%. Recoveries from different biological samples ranged from 91.50 to 105.25%. The LODs were estimated as 1.70 mg/L for PY, 1.68 mg/L for GA, 1.52 mg/L for RE and 0.98 mg/L for EA with a 20 microL injection volume. The method was applied for the determination of these compounds in oak leaves and in ruminal fluid and urine samples taken from beef cattle fed with oak leaves. The proposed method could be used in ruminant nutrition studies to verify the effect that a diet rich in tannins have on ruminal fermentation and to determine the toxicity of these compounds.

  6. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  7. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  8. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  9. 40 CFR 86.1326-90 - Calibration of other equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and ultraviolet detector for measuring...

  10. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  11. Artificial neural network model for photosynthetic pigments identification using multi wavelength chromatographic data

    NASA Astrophysics Data System (ADS)

    Prilianti, K. R.; Hariyanto, S.; Natali, F. D. D.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2016-04-01

    The development of rapid and automatic pigment characterization method become an important issue due to the fact that there are only less than 1% of plant pigments in the earth have been explored. In this research, a mathematical model based on artificial intelligence approach was developed to simplify and accelerate pigment characterization process from HPLC (high-performance liquid chromatography) procedure. HPLC is a widely used technique to separate and identify pigments in a mixture. Input of the model is chromatographic data from HPLC device and output of the model is a list of pigments which is the spectrum pattern is discovered in it. This model provides two dimensional (retention time and wavelength) fingerprints for pigment characterization which is proven to be more accurate than one dimensional fingerprint (fixed wavelength). Moreover, by mimicking interconnection of the neuron in the nervous systems of the human brain, the model have learning ability that could be replacing expert judgement on evaluating spectrum pattern. In the preprocessing step, principal component analysis (PCA) was used to reduce the huge dimension of the chromatographic data. The aim of this step is to simplify the model and accelerate the identification process. Six photosynthetic pigments i.e. zeaxantin, pheophytin a, α-carotene, β-carotene, lycopene and lutein could be well identified by the model with accuracy up to 85.33% and processing time less than 1 second.

  12. A unified classification of stationary phases for packed column supercritical fluid chromatography.

    PubMed

    West, C; Lesellier, E

    2008-05-16

    The use of supercritical fluids as chromatographic mobile phases allows to obtain rapid separations with high efficiency on packed columns, which could favour the replacement of numerous HPLC methods by supercritical fluid chromatography (SFC) ones. Moreover, despite some unexpected chromatographic behaviours, general retention rules are now well understood, and mainly depend on the nature of the stationary phase. The use of polar stationary phases improves the retention of polar compounds, when C18-bonded silica favours the retention of hydrocarbonaceous compounds. In this sense, reversed-phase and normal-phase chromatography can be achieved in SFC, as in HPLC. However, these two domains are clearly separated in HPLC due to the opposite polarity of the mobile phases used for each method. In SFC, the same mobile phase can be used with both polar and non-polar stationary phases. Consequently, the need for a novel classification of stationary phases in SFC appears, allowing a unification of the classical reversed- and normal-phase domains. In this objective, the paper presents the development of a five-dimensional classification based on retention data for 94-111 solutes, using 28 commercially available columns representative of three major types of stationary phases. This classification diagram is based on a linear solvation energy relationship, on the use of solvation vectors and the calculation of similarity factors between the different chromatographic systems. This classification will be of great help in the choice of the well-suited stationary phase, either in regards of a particular separation or to improve the coupling of columns with complementary properties.

  13. Ion Chromatography-on-a-chip for Water Quality Analysis

    NASA Technical Reports Server (NTRS)

    Kidd, R. D.; Noell, A.; Kazarians, G.; Aubrey, A. D.; Scianmarello, N.; Tai, Y.-C.

    2015-01-01

    We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

  14. 40 CFR 86.126-90 - Calibration of other equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... according to good practice. Specific equipment requiring calibration are the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and...

  15. 40 CFR 86.526-90 - Calibration of other equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... necessary according to good practice. Specific equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC...

  16. 40 CFR 86.126-90 - Calibration of other equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... according to good practice. Specific equipment requiring calibration are the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC) and...

  17. 40 CFR 86.526-90 - Calibration of other equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... necessary according to good practice. Specific equipment requiring calibration is the gas chromatograph and flame ionization detector used in measuring methanol and the high pressure liquid chromatograph (HPLC...

  18. Modeling the drugs' passive transfer in the body based on their chromatographic behavior.

    PubMed

    Kouskoura, Maria G; Kachrimanis, Kyriakos G; Markopoulou, Catherine K

    2014-11-01

    One of the most challenging aims in modern analytical chemistry and pharmaceutical analysis is to create models for drugs' behavior based on simulation experiments. Since drugs' effects are closely related to their molecular properties, numerous characteristics of drugs are used in order to acquire a model of passive absorption and transfer in the human body. Importantly, such direction in innovative bioanalytical methodologies is also of stressful need in the area of personalized medicine to implement nanotechnological and genomics advancements. Simulation experiments were carried out by examining and interpreting the chromatographic behavior of 113 analytes/drugs (400 observations) in RP-HPLC. The dataset employed for this purpose included 73 descriptors which are referring to the physicochemical properties of the mobile phase mixture in different proportions, the physicochemical properties of the analytes and the structural characteristics of their molecules. A series of different software packages was used to calculate all the descriptors apart from those referring to the structure of analytes. The correlation of the descriptors with the retention time of the analytes eluted from a C4 column with an aqueous mobile phase was employed as dataset to introduce the behavior models in the human body. Their evaluation with a Partial Least Squares (PLS) software proved that the chromatographic behavior of a drug on a lipophilic stationary and a polar mobile phase is directly related to its drug-ability. At the same time, the behavior of an unknown drug in the human body can be predicted with reliability via the Artificial Neural Networks (ANNs) software. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. [Determination of homocysteine level in plasma by high performance liquids chromatography with fluorescence detection].

    PubMed

    Da, Xu; Qian, Ling-Jia

    2005-08-01

    To establish a method for detection of plasma total homocysteine with HPLC. The chromatography analysis was carried out using a Symmetry Shield RP18. The mobile phase was sodium acetate (0.08 mol/L) and methanol (1%) and we utilized a HPLC system with fluorescence detection of plasma homocysteine derivatized from reaction with 7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate (SBD-F). The average recoveries were 95.8 - 100.8% and the relative standard deviations were 1.2-2.0%. The results showed it to be a rapid and accurate method for the determination of homocysteine level in plasma.

  20. Determination of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations by HPLC.

    PubMed

    Almeida, M M; Alves, J M P; Patto, D C S; Lima, C R R C; Quenca-Guillen, J S; Santoro, M I R M; Kedor-Hackmann, E R M

    2009-12-01

    A rapid HPLC method was developed for the assay of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations. The validated method was applied for quantitative determination of these vitamins in simulated emulsion formulation. Samples were analysed directly on a RP-18 reverse phase column with UV detection at 222 nm. A mixture of methanol and isopropanol (25 : 75 v/v) was used as mobile phase. The retention time of tocopheryl acetate and ascorbyl tetraisopalmitate were 3.0 min and 5.9 min, respectively. Recovery was between 95% and 104%. In addition, the excipients did not interfere in the analysis. The method is simple, reproducible, selective and is suitable for routine analyses of commercial products.

  1. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    PubMed

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  2. Reductive amination of aldehyde 2,4-dinitorophenylhydrazones using 2-picoline borane and high-performance liquid chromatographic analysis.

    PubMed

    Uchiyama, Shigehisa; Inaba, Yohei; Matsumoto, Mariko; Suzuki, Gen

    2009-01-01

    A new method for the determination of carbonyls in air using 2,4-dinitrophenylhydrazine (DNPH) has been developed. The traditional method for the measurement of carbonyl compounds, using DNPH to form the corresponding 2,4-dinitrophenylhydrazone (DNPhydrazone) derivatives, is subject to analytical errors because DNPhydrazones form both E- and Z-geometrical isomers as a result of the C=N double bond. To overcome this issue, a method for transforming the C=N double bond into a C-N single bond, using reductive amination of DNPhydrazone derivatives, has been developed. Reductive amination of aldehyde DNPhydrazones was carried out by adding 2-picoline borane acetonitrile solution in eluate through the DNPH-cartridge. The amination reactions of C(1)-C(10) aldehyde DNPhydrazones were completely converted into the reduced forms within 40 min in the presence of 1 mmol/L 2-picoline borane and 20 mmol/L of phosphoric acid. These reduced forms were very stable and did not change when stored for 2 weeks at room temperature. The absorption maximum wavelengths of the reduced forms from C(1)-C(10) aldehyde DNPhydrazones were 351-352 nm and shifted 6-7 nm toward shorter wavelengths when compared to the corresponding DNPhydrazones, and the molar absorption coefficients were 1.5 x 10(4) (C(1)) to 2.2 x 10(4) L/mol/cm (C(10)). Complete separation between C(1)-C(10) aldehyde DNPhydrazones and the corresponding reduced forms can be achieved by operating the HPLC in gradient mode using an Ascentis RP-Amide column (150 mm x 4.6 mm i.d.). The RSDs of DNPhydrazone (Z + E) peak areas ranged from 0.40-0.66 and those of the corresponding reduced forms ranged from 0.26-0.41. It was shown that the reductive amination method gave improved HPLC analytical precision because of the absence of isomers.

  3. Development and optimization of SPE-HPLC-UV/ELSD for simultaneous determination of nine bioactive components in Shenqi Fuzheng Injection based on Quality by Design principles.

    PubMed

    Wang, Lu; Qu, Haibin

    2016-03-01

    A method combining solid phase extraction, high performance liquid chromatography, and ultraviolet/evaporative light scattering detection (SPE-HPLC-UV/ELSD) was developed according to Quality by Design (QbD) principles and used to assay nine bioactive compounds within a botanical drug, Shenqi Fuzheng Injection. Risk assessment and a Plackett-Burman design were utilized to evaluate the impact of 11 factors on the resolutions and signal-to-noise of chromatographic peaks. Multiple regression and Pareto ranking analysis indicated that the sorbent mass, sample volume, flow rate, column temperature, evaporator temperature, and gas flow rate were statistically significant (p < 0.05) in this procedure. Furthermore, a Box-Behnken design combined with response surface analysis was employed to study the relationships between the quality of SPE-HPLC-UV/ELSD analysis and four significant factors, i.e., flow rate, column temperature, evaporator temperature, and gas flow rate. An analytical design space of SPE-HPLC-UV/ELSD was then constructed by calculated Monte Carlo probability. In the presented approach, the operating parameters of sample preparation, chromatographic separation, and compound detection were investigated simultaneously. Eight terms of method validation, i.e., system-suitability tests, method robustness/ruggedness, sensitivity, precision, repeatability, linearity, accuracy, and stability, were accomplished at a selected working point. These results revealed that the QbD principles were suitable in the development of analytical procedures for samples in complex matrices. Meanwhile, the analytical quality and method robustness were validated by the analytical design space. The presented strategy provides a tutorial on the development of a robust QbD-compliant quantitative method for samples in complex matrices.

  4. Analysis and quality control of carbohydrates in therapeutic proteins with fluorescence HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kun; Huang, Jian; Center for Informational Biology, University of Electronic Science and Technology of China, Chengdu 610054

    Conbercept is an Fc fusion protein with very complicated carbohydrate profiles which must be carefully monitored through manufacturing process. Here, we introduce an optimized fluorescence derivatization high-performance liquid chromatographic method for glycan mapping in conbercept. Compared with conventional glycan analysis method, this method has much better resolution and higher reproducibility making it excellent for product quality control.

  5. Isocratic RP-HPLC method for rutin determination in solid oral dosage forms.

    PubMed

    Kuntić, Vesna; Pejić, Natasa; Ivković, Branka; Vujić, Zorica; Ilić, Katarina; Mićić, Svetlana; Vukojević, Vladana

    2007-01-17

    A rapid and sensitive assay for quantitative determination of rutin in oral dosage forms based on isocratic reversed phase high performance liquid chromatography (RP-HPLC) was developed and validated. Using a C(18) reverse-phase analytical column, the following conditions were chosen as optimal: mobile phase methanol-water 1:1 (v/v), pH 2.8 (adjusted with phosphoric acid), flow rate=1 mL min(-1) and temperature T=40.0 degrees C. Linearity was observed in the concentration range 8-120 microg mL(-1) with a correlation coefficient of 0.99982 and the limit of detection (LOD)=2.6 microg mL(-1), and limit of quantification (LOQ)=8.0 microg mL(-1). Intra- and inter-day precision were within acceptable limits. Robustness test indicated that the mobile phase composition and pH influence mainly the separation. The proposed method allowed direct determination of rutin in pharmaceutical dosage forms in the presence of excipients, but is not suitable for preparations where compounds structurally/chemically related to rutin may be present.

  6. Quantitative analysis of iridoids, secoiridoids, xanthones and xanthone glycosides in Gentiana lutea L. roots by RP-HPLC and LC-MS.

    PubMed

    Aberham, Anita; Schwaiger, Stefan; Stuppner, Hermann; Ganzera, Markus

    2007-11-05

    The here described HPLC-method enables the determination of all major, currently known bioactive compounds in gentian roots. A separation of iridoids (loganic acid), secoiridoids (swertiamarin, gentiopicroside, amarogentin, sweroside), xanthones (gentisin, isogentisin) and two xanthone glycosides (gentiosides) was possible on RP-18 column material, using 0.025% aqueous TFA, acetonitrile and n-propanol as mobile phase. The method is sensitive (LOD

  7. Quantification of 4'-geranyloxyferulic acid (GOFA) in honey samples of different origin by validated RP-HPLC-UV method.

    PubMed

    Genovese, Salvatore; Taddeo, Vito Alessandro; Fiorito, Serena; Epifano, Francesco

    2016-01-05

    Natural honey has been employed as a nutraceutical agent with benefits and therapeutic promises for humans for many centuries. It has been largely used as food and medicine by all generations, traditions, and civilizations, both ancient and modern. Several chemicals having beneficial effects for human health have been reported as components of natural honey and these include sugars, organic acids, aminoacids, minerals, and vitamins. Also some important phytochemicals have been described and these comprise tannins, flavonoids, terpenes, saponins, and alkaloids. In this note it is described the successful application of a RP HPLC-UV-vis method for the separation and quantification of 4'-geranyloxyferulic acid (GOFA) in four honey samples of different origin. Concentration values showed a great variation between the four samples tested, being chestnut honey the one richest in GOFA (7.87 mg/g). The findings described herein represent the first example reported in the literature of the characterization of an oxyprenylated phenylpropanoid in honey. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Alternative measures of lipophilicity: from octanol-water partitioning to IAM retention.

    PubMed

    Giaginis, Costas; Tsantili-Kakoulidou, Anna

    2008-08-01

    This review describes lipophilicity parameters currently used in drug design and QSAR studies. After a short historical overview, the complex nature of lipophilicity as the outcome of polar/nonpolar inter- and intramolecular interactions is analysed and considered as the background for the discussion of the different lipophilicity descriptors. The first part focuses on octanol-water partitioning of neutral and ionisable compounds, evaluates the efficiency of predictions and provides a short description of the experimental methods for the determination of distribution coefficients. A next part is dedicated to reversed-phase chromatographic techniques, HPLC and TLC in lipophilicity assessment. The two methods are evaluated for their efficiency to simulate octanol-water and the progress achieved in the refinement of suitable chromatographic conditions, in particular in the field of HPLC, is outlined. Liposomes as direct models of biological membranes are examined and phospolipophilicity is compared to the traditional lipophilicity concept. Difficulties associated with liposome-water partitioning are discussed. The last part focuses on Immobilised Artificial Membrane (IAM) chromatography as an alternative which combines membrane simulation with rapid measurements. IAM chromatographic retention is compared to octanol-water and liposome-water partitioning as well as to reversed-phase retention and its potential to predict biopartitioning and biological activities is discussed.

  9. Development and validation of a reversed-phase fluorescence HPLC method for determination of bucillamine in human plasma using pre-column derivatization with monobromobimane.

    PubMed

    Lee, Kang Choon; Chun, Young Goo; Kim, Insoo; Shin, Beom Soo; Park, Eun-Seok; Yoo, Sun Dong; Youn, Yu Seok

    2009-07-15

    A simple, specific and sensitive derivatization with monobromobimane (mBrB) and the corresponding HPLC-fluorescence quantitation method for the analysis of bucillamine in human plasma was developed and validated. The analytical procedure involves a simple protein precipitation, pre-column fluorescence derivatization, and separation by reversed-phase high performance liquid chromatography (RP-HPLC). The calibration curve showed good linearity over a wide concentration range (50 ng/mL to 10 microg/mL) in human plasma (r(2)=0.9998). The lower limit of quantitation (LLOQ) was 50 ng/mL. The average precision and accuracy at LLOQ were within 6.3% and 107.6%, respectively. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (300 mg) of bucillamine to 20 healthy Korean volunteers.

  10. Partial Characterization of Venom from the Colombian Spider Phoneutria Boliviensis (Aranae:Ctenidae)

    PubMed Central

    Estrada-Gomez, Sebastian; Vargas Muñoz, Leidy Johana; Lanchero, Paula; Segura Latorre, Cesar

    2015-01-01

    We report on the first studies on the characterization of venom from Phoneutria boliviensis (Aranae:Ctenidae) (F. O. Pickard-Cambridge, 1897), done with Colombian species. After the electrostimulation extraction process, the venom showed physicochemical properties corresponding to a colorless and water-soluble liquid with a density of 0.86 mg/mL and 87% aqueous content. P. boliviensis venom and RP-HPLC fractions showed hemolytic activity and hydrolyzed the synthetic substrate 4-nitro-3-octanoyloxy-benzoic acid, indicating the presence of phospholipases A2 enzymes. The electrophoretic profile showed an important protein content with molecular masses below 14 kDa, and differences between male and female protein content were also revealed. The RP-HPLC venom profile exposes differences between males and female content consistent with the electrophoretic profile. Five fractions collected from the RP-HPLC displayed significant larvicidal activity. Mass analysis indicates the presence of peptides ranging from 1047.71 to 3278.07 Da. Two peptides, Ctenitoxin-Pb48 and Ctenitoxin-Pb53, were partially identified using HPLC-nESI-MS/MS, which showed a high homology with other Ctenitoxins (family Tx3) from Phoneutria nigriventer, Phoneutria keyserlingi and Phoneutria reidyi affecting voltage-gated calcium receptors (Cav 1, 2.1, 2.2 and 2.3) and NMDA-glutamate receptors. PMID:26264023

  11. Comparison of the BioRad Variant and Primus Ultra2 high-pressure liquid chromatography (HPLC) instruments for the detection of variant hemoglobins.

    PubMed

    Gosselin, R C; Carlin, A C; Dwyre, D M

    2011-04-01

    Hemoglobin variants are a result of genetic changes resulting in abnormal or dys-synchronous hemoglobin chain production (thalassemia) or the generation of hemoglobin chain variants such as hemoglobin S. Automated high-pressure liquid chromatography (HPLC) systems have become the method of choice for the evaluation of patients suspected with hemoglobinopathies. In this study, we evaluated the performance of two HPLC methods used in the detection of common hemoglobin variants: Variant and Ultra2. There were 377 samples tested, 26% (99/377) with HbS, 8.5% (32/377) with HbC, 20.7% (78/377) with other hemoglobin variant or thalassemia, and 2.9% with increased hemoglobin A(1) c. The interpretations of each chromatograph were compared. There were no differences noted for hemoglobins A(0), S, or C. There were significant differences between HPLC methods for hemoglobins F, A(2), and A(1) c. However, there was good concordance between normal and abnormal interpretations (97.9% and 96.2%, respectively). Both Variant and Ultra2 HPLC methods were able to detect most common hemoglobin variants. There was better discrimination for fast hemoglobins, between hemoglobins E and A(2), and between hemoglobins S and F using the Ultra2 HPLC method. © 2010 Blackwell Publishing Ltd.

  12. Simultaneous column chromatographic extraction and purification of abscisic acid in peanut plants for direct HPLC analysis.

    PubMed

    Zhang, Ya-Wen; Fan, Wei-Wei; Li, Hui; Ni, He; Han, Han-Bing; Li, Hai-Hang

    2015-10-01

    Abscisic acid (ABA), a universal signaling molecule, plays important roles in regulating plant growth, development and stress responses. The low contents and complex components in plants make it difficult to be accurately analyzed. A novel one-step sample preparation method for ABA in plants was developed. Fresh peanut (Arachis hypogaea) plant materials were fixed by oven-drying, microwave drying, boiling or Carnoy's fixative, and loaded onto a mini-preparing column. After washed the impurities, ABA was eluted with a small amount of solvent. ABA in plant materials was completely extracted and purified in 2mL solution and directly analyzed by HPLC, with a 99.3% recovery rate. Multiple samples can be simultaneously prepared. Analyses using this method indicated that the endogenous ABA in oven-dried peanut leaves increased 20.2-fold from 1.01 to 20.37μgg(-1) dry weight within 12h and then decreased in 30% polyethylene glycol 6000 treated plants, and increased 3.34-fold from 0.85 to 2.84μgg(-1) dry weight in 5 days and then decreased in soil drought treated plants. The method combined the column chromatographic extraction and solid-phase separation technologies in one step and can completely extracted plant endogenous ABA in a purified and highly concentrated form for direct HPLC analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. A new application of micellar liquid chromatography in the determination of free ampicillin concentration in the drug-human serum albumin standard solution in comparison with the adsorption method.

    PubMed

    Stępnik, Katarzyna E; Malinowska, Irena; Maciejewska, Małgorzata

    2016-06-01

    The determination of free drug concentration is a very important issue in the field of pharmacology because only the unbound drug fraction can achieve a pharmacological effect. Due to the ability to solubilize many different compounds in micellar aggregates, micellar liquid chromatography (MLC) can be used for direct determination of free drug concentration. Proteins are not retained on the stationary phase probably due to the formation of protein - surfactant complexes which are excluded from the pores of stationary phase. The micellar method is simple and fast. It does not require any pre-preparation of the tested samples for analysis. The main aim of this paper is to demonstrate a completely new applicability of the analytical use of MLC concerning the determination of free drug concentration in the standard solution of human serum albumin. The well-known adsorption method using RP-HPLC and the spectrophotometric technique was applied as the reference method. The results show that the free drug concentration value obtained in the MLC system (based on the RP-8 stationary phase and CTAB) is similar to that obtained by the adsorption method: both RP-HPLC (95.83μgmL(-1), 79.86% of free form) and spectrophotometry (95.71μgmL(-1), 79.76%). In the MLC the free drug concentration was 93.98μgmL(-1) (78.3%). This indicates that the obtained results are within the analytical range of % of free ampicillin fraction and the MLC with direct sample injection can be treated like a promising method for the determination of free drug concentration. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Improved method for the on-line metal chelate affinity chromatography-high-performance liquid chromatographic determination of tetracycline antibiotics in animal products.

    PubMed

    Cooper, A D; Stubbings, G W; Kelly, M; Tarbin, J A; Farrington, W H; Shearer, G

    1998-07-03

    An improved on-line metal chelate affinity chromatography-high-performance liquid chromatography (MCAC-HPLC) method for the determination of tetracycline antibiotics in animal tissues and egg has been developed. Extraction was carried out with ethyl acetate. The extract was then evaporated to dryness and reconstituted in methanol prior to on-line MCAC clean-up and HPLC-UV determination. Recoveries of tetracycline, oxytetracycline, demeclocycline and chlortetracycline in the range 42% to 101% were obtained from egg, poultry, fish and venison tissues spiked at 25 micrograms kg-1. Limits of detection less than 10 microgram kg-1 were estimated for all four analytes. This method has higher throughput, higher recovery and lower limits of detection than a previously reported on-line MCAC-HPLC method which involved aqueous extraction and solid-phase extraction clean-up.

  15. [Chemical constituents of Jasminum giraldii and their antioxidant activity].

    PubMed

    Zhang, Xiu-Peng; Qin, Hui; Yang, Fang; Chai, Jiang; Wang, Xin; Song, Xiao-Mei; Mei, Qi-Bing; Feng, Feng; Yue, Zheng-Gang

    2014-06-01

    Ten compounds were isolated from the barks of Jasminum giraldii by means of various of chromatographic techniques such as silica gel, Sephadex LH-20 and Rp-HPLC. Their structures were identified by spectroscopic data analysis as (+)-medioresinol (1), (+) -syringaresinol (2), syringaresinol-4'-O-beta-D-glucopyranoside (3), oleanic acid (4), 3-methoxy-4-hydroxy-trans-cinnamaldehyde (5), trans-sinapaldehyde (6), syringaldehyde (7), 1-(4-methoxy -phenyl) -ethanol (8), trans-cinnamic acid (9), and 4-(1-methoxyethyl) -phenol (10). Among them, compounds 1-3, 5-8 and 10 were isolated from the J. genus for the first time and compounds 4 and 9 were obtained from J. giraldii for the first time. In the DPPH free radical scavenging assay, compound 1 exhibited significant activity (IC50 55.1 micromol x L(-1)), compared with vitamin C(IC50 59.9 micromol x L(-1)); and compound 2 showed moderate activity (IC50 79.0 micromol x L(-1)), compared with 2, 6-di-tert-butyl4-methylphenol (IC50 236 micromol x L(-1)).

  16. Taste and chemical characteristics of low molecular weight fractions from tofuyo - Japanese fermented soybean curd.

    PubMed

    Lioe, Hanifah Nuryani; Kinjo, Ayano; Yasuda, Shin; Kuba-Miyara, Megumi; Tachibana, Shinjiro; Yasuda, Masaaki

    2018-06-30

    Tofuyo, a Japanese traditional food, is a fermented soybean curd manufactured in Okinawa region. Due to its original cheese-like flavor, the current study was designed to evaluate the sensory and chemical characteristics of three stepwise ultrafiltration fractions, using 10,000, 3000 and 500 Da membranes and further chromatographic fractions from tofuyo. The results showed that umami, sweet and salty were the characteristic tastes of all fractions, with umami intensity evaluated for the fraction with MW less than 500 Da (F-500) as the most prominent among the three fractions. Subsequent Sephadex G-25 SF fractions and RP-HPLC fractions were subjected to sensory and chemical analyses. The tastiest fraction contained sodium chloride, sugars, organic acids, umami and sweet free amino acids, at concentrations above their thresholds. The abundant presence of umami and sweet free amino acids with certain concentrations of sodium chloride and glucose might provide the typical savory taste of tofuyo. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. A validated stability indicating RP-HPLC method for estimation of Armodafinil in pharmaceutical dosage forms and characterization of its base hydrolytic product.

    PubMed

    Venkateswarlu, Kambham; Rangareddy, Ardhgeri; Narasimhaiah, Kanaka; Sharma, Hemraj; Bandi, Naga Mallikarjuna Raja

    2017-01-01

    The main objective of present study was to develop a RP-HPLC method for estimation of Armodafinil in pharmaceutical dosage forms and characterization of its base hydrolytic product. The method was developed for Armodafinil estimation and base hydrolytic products were characterized. The separation was carried out on C18 column by using mobile phase as mixture of water and methanol (45:55%v/v). Eluents were detected at 220nm at 1ml/min. Stress studies were performed with milder conditions followed by stronger conditions so as to get sufficient degradation around 20%. A total of five degradation products were detected and separated from analyte. The linearity of the proposed method was investigated in the range of 20-120µg/ml for Armodafinil. The detection limit and quantification limit was found to be 0.01183μg/ml and 0.035µg/ml respectively. The precision % RSD was found to be less than 2% and the recovery was between 98-102%. Armodafinil was found to be more sensitive to the base hydrolysis and yielded its carboxylic acid as degradant. The developed method was stability indicating assay, suitable to quantify Armodafinil in presence of possible degradants. The drug was sensitive to acid, base &photolytic stress and resistant to thermal &oxidation.

  18. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  19. Development of a Thiolysis HPLC Method for the Analysis of Procyanidins in Cranberry Products.

    PubMed

    Gao, Chi; Cunningham, David G; Liu, Haiyan; Khoo, Christina; Gu, Liwei

    2018-03-07

    The objective of this study was to develop a thiolysis HPLC method to quantify total procyanidins, the ratio of A-type linkages, and A-type procyanidin equivalents in cranberry products. Cysteamine was utilized as a low-odor substitute of toluene-α-thiol for thiolysis depolymerization. A reaction temperature of 70 °C and reaction time of 20 min, in 0.3 M of HCl, were determined to be optimum depolymerization conditions. Thiolytic products of cranberry procyanidins were separated by RP-HPLC and identified using high-resolution mass spectrometry. Standards curves of good linearity were obtained on thiolyzed procyanidin dimer A2 and B2 external standards. The detection and quantification limits, recovery, and precision of this method were validated. The new method was applied to quantitate total procyanidins, average degree of polymerization, ratio of A-type linkages, and A-type procyanidin equivalents in cranberry products. Results showed that the method was suitable for quantitative and qualitative analysis of procyanidins in cranberry products.

  20. Simultaneous determination of methocarbamol and aspirin by RP-HPLC using fluorescence detection with time programming: its application to pharmaceutical dosage form.

    PubMed

    El-Din, M Sharaf; Eid, M; Zeid, A M

    2013-01-01

    A new simple, rapid and sensitive reversed-phase liquid chromatographic method was developed and validated for the simultaneous determination of methocarbamol (MET) and aspirin (ASP) in their combined dosage form. The separation of these compounds was achieved within 6.0 min on a CLC Shim-pack C8 column (250 × 4.6 mm, 5 µm particle size) using isocratic mobile phase consisting of acetonitrile and 0.02 M dihydrogenphosphate buffer (30:70, v/v) at pH = 5.0. The analysis was performed at a flow rate of 1.0 mL/min with fluorescence detection at 277/313 nm for MET and 298/410 nm for ASP using real-time programming. The selectivity, linearity of calibration, accuracy, inter- and intra-day precision and recovery were examined as parts of the method validation. The concentration-response relationship was linear over concentration ranges of 0.02-0.20 and 0.02-0.40 µg/mL for MET and ASP, respectively, with a limit of detection of 6 and 32 ng/mL for MET and ASP, respectively. The proposed method was successfully applied for the analysis of both MET and ASP in prepared tablets with average recoveries of 99.88 ± 0.65% for MET and 100.44 ± 0.78% for ASP. The results were favourably compared to those obtained by a reference method. Copyright © 2012 John Wiley & Sons, Ltd.

  1. High-performance liquid chromatographic method for the simultaneous determination of 24 fragrance allergens to study scented products.

    PubMed

    Villa, C; Gambaro, R; Mariani, E; Dorato, S

    2007-07-27

    The European legislation on cosmetic products has recently required the declaration of 26 compounds (24 volatile chemicals and 2 natural extracts) on the label of final products when exceeding a stipulated cut-off level. In this work a rapid reliable and specific RP-HPLC method coupled with diode array detector (DAD) has been developed for the simultaneous determination and quantification of the 24 volatile chemicals: amyl cinnamal, benzyl alcohol, cinnamyl alcohol, citral, eugenol, hydroxy-citronellal, isoeugenol, amylcinnamyl alcohol, benzyl salicylate, cinnamal, coumarin, geraniol, Lyral (hydroxy-methylpentylcyclohexene carboxaldehyde), anisyl alcohol, benzyl cinnamate, farnesol, Lilial (2-(4-tert-butylbenzyl)propionaldehyde) linalool, benzyl benzoate, citronellol, hexyl cinnamal, limonene, methylheptin carbonate, alpha-isomethyl ionone (3-methyl-4-(2,6,6-trimethyl-2-cyclohexen-1-yl)-3-buten-2-one). The 24 analytes were appropriately separated over a running time of 40 min, on a C18 column using a simple gradient elution (acetonitrile/water) with flow rate from 0.7 to 1.0 ml/min and UV acquisition at 210, 254 and 280 nm. All calibration curves showed good linearity (r2>0.99) within test ranges. The method was successfully applied to the qualitative and quantitative determination of the potential allergens in four commercial scented products, with satisfactory accuracy and precision. The results indicated that this simple and efficient method can be used for quality assessment of complex matrices such us cosmetic scented products.

  2. Determination of nifedipine in serum of women in preterm labor by high-performance liquid chromatography with diode array detection.

    PubMed

    Kowalczuk, Dorota; Wawrzycka, Maria Bozena; Haratym Maj, Agnieszka

    2006-01-01

    Nifedipine (Nif) is widely used in treating cardiovascular disorders (especially hypertension) and for inhibiting preterm labor. A fully validated selective high-performance liquid chromatographic method with diode array detection, using solid-phase extraction, was developed for the determination of Nif in human serum. To assess specificity, Nif and its degradation products were separated on a Purospher RP-18 (5 microm, 125 x 4 mm) column plus a LiChrospher 100 RP-18 (5 microm, 4 x 4 mm) precolumn with a mobile phase of methanol-10 mM aqueous trifluoroacetic acid, pH 7.3 (57 + 43, v/v); chromatographic separation was followed by UV detection at 238 nm. For toxicological analysis, Nif in the presence of other calcium-channel antagonist drugs was identified under optimum chromatographic conditions. The calibration graph was constructed over the concentration range of 12.5-400 ng/mL in serum with good correlation (r = 0.9956). This method was not subject to interference by other plasma components and was successfully applied to the assay of Nif in spiked human serum and in serum of women in preterm labor after sublingual administration of 30 mg Nif per day divided into 3 equal doses. The mean recovery based on the ratio of the slopes of serum and mobile phase standard curves was 96.5%. The detection and quantification limits of the drug in spiked human serum were found to be 6 and 17.5 ng/mL, respectively. Validation of the method demonstrated good intraday and interday precision, which ranged from 2.18 to 6.67% and from 6.52 to 11.93%, respectively.

  3. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    USGS Publications Warehouse

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  4. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    USDA-ARS?s Scientific Manuscript database

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  5. Use of a multifunctional column for the determination of deoxynivalenol in grains, grain products, and processed foods.

    PubMed

    Bao, Lei; Oles, Carolyn J; White, Kevin D; Sapp, Chelsea; Trucksess, Mary W

    2011-01-01

    Deoxynivalenol (DON), also known as vomitoxin, belongs to a class of naturally occurring mycotoxins produced by Fusarium spp. DON, 12, 13-epoxy-3,7 trihydroxytrichothec-9-en-8-one, is one of the most frequently detected mycotoxins in agricultural commodities worldwide. A method consisting of extraction, filtration, column cleanup, and RP-HPLC-UV separation and quantitation was validated for the determination of DON in grains (rice and barley), grain products (whole wheat flour, white flour, wheat germ, and wheat bran), and processed foods (bread, breakfast cereals, and pretzels). A 25 g test portion was extracted with 100 mL acetonitrile-water (84 + 16, v/v). After blending for 3 min, the supernatant was applied to a multifunctional column (MycoSep 225). The purified filtrate (2 mL) was evaporated to dryness and redissolved in the mobile phase. The toxins were then subjected to RP-HPLC-UV analysis. The accuracy and repeatability characteristics of the method were determined. Recoveries of DON added at levels ranging from 0.5 to 1.5 microg/g for all test matrixes were from 75 to 98%. SD and RSD(r) ranged from 0.7 to 11.6% and 0.9 to 12.7%, respectively. Within-laboratory HorRat values were from 0.1 to 0.7 for all matrixes analyzed. The method was found to meet AOAC method performance criteria for grains, grain products, and processed foods. The identity of DON in naturally contaminated test sample extracts was confirmed by HPLC/MS/MS analysis.

  6. [Determination of glycyrrhizinic acid in biotransformation system by reversed-phase high performance liquid chromatography].

    PubMed

    Li, Hui; Lu, Dingqiang; Liu, Weimin

    2004-05-01

    A method for determining glycyrrhizinic acid in the biotransformation system by reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The HPLC conditions were as follows: Hypersil C18 column (4.6 mm i.d. x 250 mm, 5 microm) with a mixture of methanol-water-acetic acid (70:30:1, v/v) as the mobile phase; flow rate at 1.0 mL/min; and UV detection at 254 nm. The linear range of glycyrrhizinic acid was 0.2-20 microg. The recoveries were 98%-103% with relative standard deviations between 0.16% and 1.58% (n = 3). The method is simple, rapid and accurate for determining glycyrrhizinic acid.

  7. Simultaneous Determination of Multiple Ginsenosides in Panax ginseng Herbal Medicines with One Single Reference Standard.

    PubMed

    Wu, Chunwei; Guan, Qingxiao; Wang, Shumei; Rong, Yueying

    2017-01-01

    Root of Panax ginseng C. A. Mey (Renseng in Chinese) is a famous Traditional Chinese Medicine. Ginsenosides are the major bioactive components. However, the shortage and high cost of some ginsenoside reference standards make it is difficult for quality control of P. ginseng . A method, single standard for determination of multicomponents (SSDMC), was developed for the simultaneous determination of nine ginsenosides in P. ginseng (ginsenoside Rg 1 , Re, Rf, Rg 2 , Rb 1 , Rc, Rb 2 , Rb 3 , Rd). The analytes were separated on Inertsil ODS-3 C18 (250 mm × 4.6 mm, 5 μm) with gradient elution of acetonitrile and water. The flow rate was 1 mL/min and detection wavelength was set at 203 nm. The feasibility and accuracy of SSDMC were checked by the external standard method, and various high-performance liquid chromatographic (HPLC) instruments and chromatographic conditions were investigated to verify its applicability. Using ginsenoside Rg 1 as the internal reference substance, the contents of other eight ginsenosides were calculated according to conversion factors (F) by HPLC. The method was validated with linearity ( r 2 ≥ 0.9990), precision (relative standard deviation [RSD] ≤2.9%), accuracy (97.5%-100.8%, RSD ≤ 1.6%), repeatability, and stability. There was no significant difference between the SSDMC method and the external standard method. New SSDMC method could be considered as an ideal mean to analyze the components for which reference standards are not readily available. A method, single standard for determination of multicomponents (SSDMC), was established by high-performance liquid chromatography for the simultaneous determination of nine ginsenosides in Panax ginseng (ginsenoside Rg1, Re, Rf, Rg2, Rb1, Rc, Rb2, Rb3, Rd)Various chromatographic conditions were investigated to verify applicability of FsThe feasibility and accuracy of SSDMC were checked by the external standard method. Abbreviations used: DRT: Different value of retention time; F: Conversion factor; HPLC: High-performance Liquid Chromatography; LOD: Limit of detection; LOQ: Limit of quantitation; PD: Percent difference; PPD: 20(S)-protopanaxadiol; PPT: 20(S)-protopanaxatriol; RSD: Relative standard deviation; SSDMC: Single Standard for Determination of Multicomponents; TCM: Traditional Chinese Medicine.

  8. Synthesis and antimicrobial evaluation of two peptide LyeTx I derivatives modified with the chelating agent HYNIC for radiolabeling with technetium-99m.

    PubMed

    Fuscaldi, Leonardo Lima; Dos Santos, Daniel Moreira; Pinheiro, Natália Gabriela Silva; Araújo, Raquel Silva; de Barros, André Luís Branco; Resende, Jarbas Magalhães; Fernandes, Simone Odília Antunes; de Lima, Maria Elena; Cardoso, Valbert Nascimento

    2016-01-01

    Current diagnostic methods and imaging techniques are not able to differentiate septic and aseptic inflammation. Thus, reliable methods are sought to provide this distinction and scintigraphic imaging is an interesting option, since it is based on physiological changes. In this context, radiolabeled antimicrobial peptides have been investigated as they accumulate in infectious sites instead of aseptic inflammation. The peptide LyeTx I, from the venom of Lycosa erythrognatha, has potent antimicrobial activity. Therefore, this study aimed to synthesize LyeTx I derivatives with the chelating compound HYNIC, to evaluate their antimicrobial activity and to radiolabel them with (99m)Tc. Two LyeTx I derivatives, HYNIC-LyeTx I (N-terminal modification) and LyeTx I-K-HYNIC (C-terminal modification), were synthesized by Fmoc strategy and purified by RP-HPLC. The purified products were assessed by RP-HPLC and MALDI-ToF-MS analysis. Microbiological assays were performed against S. aureus (ATCC® 6538) and E. coli (ATCC® 10536) in liquid medium to calculate the MIC. The radiolabeling procedure of LyeTx I-K-HYNIC with (99m)Tc was performed in the presence of co-ligands (tricine and EDDA) and reducing agent (SnCl2 (.) 2H2O), and standardized taking into account the amount of peptide, reducing agent, pH and heating. Radiochemical purity analysis was performed by thin-layer chromatography on silica gel strips and the radiolabeled compound was assessed by RP-HPLC and radioactivity measurement of the collected fractions. Data were analyzed by ANOVA, followed by Tukey test (p-values < 0.05). Both LyeTx I derivatives were suitably synthesized and purified, as shown by RP-HPLC and MALDI-ToF-MS analysis. The microbiological test showed that HYNIC-LyeTx I (N-terminal modification) did not inhibit bacterial growth, whereas LyeTx I-K-HYNIC (C-terminal modification) showed a MIC of 5.05 μmol(.)L(-1) (S. aureus) and 10.10 μmol(.)L(-1) (E. coli). Thus, only the latter was radiolabeled with (99m)Tc. The radiochemical purity analysis of LyeTx I-K-HYNIC-(99m)Tc showed that the optimal radiolabeling conditions (10 μg of LyeTx I-K-HYNIC; 250 μg of SnCl2 (.) 2H2O; pH = 7; heating for 15 min) yielded a radiochemical purity of 87 ± 1 % (n = 3). However, RP-HPLC data suggested (99m)Tc transchelation from LyeTx I-K-HYNIC to the co-ligands (tricine and EDDA). The binding of HYNIC to the N-terminal portion of LyeTx I seems to affect its activity against bacteria. Nevertheless, the radiolabeling of the C-terminal derivative, LyeTx I-K-HYNIC, must be better investigated to optimize the radiolabeled compound, in order to use it as a specific imaging agent to distinguish septic and aseptic inflammation.

  9. Development and Validation of HPLC-DAD and UHPLC-DAD Methods for the Simultaneous Determination of Guanylhydrazone Derivatives Employing a Factorial Design.

    PubMed

    Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula

    2017-08-30

    Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.

  10. Sensitive and selective determination of methylenedioxylated amphetamines by high-performance liquid chromatography with fluorimetric detection.

    PubMed

    Sadeghipour, F; Veuthey, J L

    1997-11-07

    A rapid, sensitive and selective liquid chromatographic method with fluorimetric detection was developed for the separation and quantification of four methylenedioxylated amphetamines without interference of other drugs of abuse and common substances found in illicit tablets. The method was validated by examining linearity, precision and accuracy as well as detection and quantification limits. Methylenedioxylated amphetamines were quantified in eight tablets from illicit drug seizures and results were quantitatively compared to HPLC-UV analyses. To demonstrate the better sensitivity of the fluorimetric detection, methylenedioxylated amphetamines were analyzed in serum after a liquid-liquid extraction procedure and results were also compared to HPLC-UV analyses.

  11. Structural characterization of bovine beta-lactoglobulin-galactose/tagatose Maillard complexes by electrophoretic, chromatographic, and spectroscopic methods.

    PubMed

    Corzo-Martínez, Marta; Moreno, F Javier; Olano, Agustín; Villamiel, Mar

    2008-06-11

    To investigate the influence of the type of carbonyl group of the sugar on the structural changes of proteins during glycation, an exhaustive structural characterization of glycated beta-lactoglobulin with galactose (aldose) and tagatose (ketose) has been carried out. Conjugates were prepared via Maillard reaction at 40 and 50 degrees C, pH 7, and a w = 0.44. The progress of the Maillard reaction was followed by indirect formation of Amadori and Heyns compounds, advanced glycation end products, and brown polymers. The structural characterization of glycoconjugates was conducted by using a number of analytical techniques such as RP-HPLC, isoelectric focusing, MALDI-ToF, SDS-PAGE, size exclusion chromatography, and spectrofluorimetry (tryptophan fluorescence). In addition, the surface hydrophobicity of the beta-lactoglobulin glycoconjugates was also assessed. The results showed a higher reactivity of galactose than tagatose to form the glycoconjugates, probably due to the higher electrophilicity of the aldehyde group. At 40 degrees C, more aggregation was produced when beta-lactoglobulin was conjugated with tagatose as compared to galactose. However, at 50 degrees C hardly any difference was observed in the aggregation produced by galactose and tagatose. These results afford more insight into the importance of the functional group of the carbohydrate moiety during the formation of protein-carbohydrate conjugates via Maillard reaction.

  12. Terbinafine hydrochloride treatment of Microsporum canis experimentally-induced ringworm in cats.

    PubMed

    Kotnik, T; Kozuh Erzen, N; Kuzner, J; Drobnic-Kosorok, M

    2001-11-08

    Cats represent the most important source of Microsporum canis infection to people. Terbinafine hydrochloride is commonly used in the treatment of microsporosis. Its fungicidal action permits short period of treatment. It was our objective to evaluate the effectiveness of this drug in treatment of microsporosis in cats. We treated nine experimentally M. canis infected cats with terbinafine at a dose of 10-20mg/kg SID (low-dose group, LDG), nine cats with 30-40mg/kg SID (high-dose group, HDG), and nine cats were left untreated (control group, CG). The drug's levels in cats' plasma and hair were measured by a reversed-phase high performance liquid chromatographic method (RP-HPLC) and the cats' cure was followed by Wood's lamp illumination, microscopic exam and fungal culture. We showed no difference between the clinical course in CG and LDG, but HDG were significantly differentiated from both other groups. Terbinafine levels in plasma at 120 days of treatment were not statistically different among LDG (4.13 microg/l) and HDG (5.48 microg/l), but levels in hair of LDG (1.24 microg/l) and HDG (3.62 microg/l) were significantly different. Terbinafine can be used for the treatment of microsporosis in cats in the dose of 30-40mg/kg SID.

  13. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker.

    PubMed

    Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing

    2016-05-08

    Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.

  14. Reversed phase HPLC for strontium ranelate: Method development and validation applying experimental design.

    PubMed

    Kovács, Béla; Kántor, Lajos Kristóf; Croitoru, Mircea Dumitru; Kelemen, Éva Katalin; Obreja, Mona; Nagy, Előd Ernő; Székely-Szentmiklósi, Blanka; Gyéresi, Árpád

    2018-06-01

    A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20-320 μg mL-1 (R2 = 0.99998). Recovery, tested in the range of 40-120 μg mL-1, was found to be 96.1-102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0-1.4 and 1.2-1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 μg mL-1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate.

  15. High performance liquid chromatographic and thin layer densitometric methods for the determination of risperidone in the presence of its degradation products in bulk powder and in tablets.

    PubMed

    El-Sherif, Zeinab A; El-Zeany, Badr; El-Houssini, Ola M

    2005-01-04

    Two reproducible stability indicating methods were developed for the determination of risperidone (RISP) in presence of its degradation products in pure form and in tablets. The first method was based on reversed phase high performance liquid chromatography (HPLC), on Lichrosorb RP C 18 column (250 mm i.d., 4 mm, 10 microm), using methanol:0.05 M potassium dihydrogen phosphate pH 7 (65:35 (v/v)) as the mobile phase at a flow rate of 1 ml min(-1) at ambient temperature. Quantification was achieved with UV detection at 280 nm over a concentration range of 25-500 microg ml(-1) with mean percentage recovery of 99.87 +/- 1.049. The method retained its accuracy in the presence of up to 90% of RISP degradation products. The second method was based on TLC separation of RISP from its degradation products followed by densitometric measurement of the intact drug spot at 280 nm. The separation was carried out on aluminum sheet of silica gel 60F254 using acetonitrile:methanol:propanol:triethanolamine (8.5:1.2:0.6:0.2 (v/v/v/v)), as the mobile phase, over a concentration range of 2-10 microg per spot and mean percentage recovery of 100.1 +/- 1.18. The two methods were simple, precise, sensitive and could be successfully applied for the determination of pure, laboratory prepared mixtures and tablets. The results obtained were compared with the manufacturer's method.

  16. Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms.

    PubMed

    Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid

    2018-01-01

    A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be <2%. The proposed method was statistically evaluated and can be applied for routine quality control analysis of ABAC and LAMI in bulk and in tablet dosage form. Attempts were made to develop RP-HPLC method for simultaneous estimation of Abacavir and Lamivudine for the RP-HPLC method. The developed method was validated according to the ICH guidelines. The linearity, precision, range, robustness were within the limits as specified by the ICH guidelines. Hence the method was found to be simple, accurate, precise, economic and reproducible. So the proposed methods can be used for the routine quality control analysis of Abacavir and Lamivudine in bulk drug as well as in formulations. Abbreviations Used: HPLC: High-performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.

  17. Analytical Methods for Determining Nitroguanidine in Soil and Water

    DTIC Science & Technology

    1989-11-01

    Westerdahl 1986, Manning and Maskar- inec 1987) eluted with a mobile phase that is pre- Table 2. Summary of high-performance liquid chromatographic methods...mg/L Ogle and Westerdahl (1986) 3 mL/min dominantly water. Nitroguanidine is not well re- saved using a Hewlett Packard 9114B disk drive. tained on...the ex- Ogle, E.E. and R.P. Westerdahl (1986) On-line tracts are filtered through 0.45-pm membranes. monitors for water pollutants. USA Armament Re

  18. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    PubMed

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  19. Correlations between chromatographic parameters and bioactivity predictors of potential herbicides.

    PubMed

    Janicka, Małgorzata

    2014-08-01

    Different liquid chromatography techniques, including reversed-phase liquid chromatography on Purosphere RP-18e, IAM.PC.DD2 and Cosmosil Cholester columns and micellar liqud chromatography with a Purosphere RP-8e column and using buffered sodium dodecyl sulfate-acetonitrile as the mobile phase, were applied to study the lipophilic properties of 15 newly synthesized phenoxyacetic and carbamic acid derivatives, which are potential herbicides. Chromatographic lipophilicity descriptors were used to extrapolate log k parameters (log kw and log km) and log k values. Partitioning lipophilicity descriptors, i.e., log P coefficients in an n-octanol-water system, were computed from the molecular structures of the tested compounds. Bioactivity descriptors, including partition coefficients in a water-plant cuticle system and water-human serum albumin and coefficients for human skin partition and permeation were calculated in silico by ACD/ADME software using the linear solvation energy relationship of Abraham. Principal component analysis was applied to describe similarities between various chromatographic and partitioning lipophilicities. Highly significant, predictive linear relationships were found between chromatographic parameters and bioactivity descriptors. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Simultaneous determination of atorvastatin calcium and olmesartan medoxomil in a pharmaceutical formulation by reversed phase high-performance liquid chromatography, high-performance thin-layer chromatography, and UV spectrophotometric methods.

    PubMed

    Soni, Hiral; Kothari, Charmy; Khatri, Deepak; Mehta, Priti

    2014-01-01

    Validated RP-HPLC, HPTLC, and UV spectrophotometric methods have been developed for the simultaneous determination of atorvastatin calcium (ATV) and olmesartan medoxomil (OLM) in a pharmaceutical formulation. The RP-HPLC separation was achieved on a Kromasil C18 column (250 x 4.6 mm, 5 microm particle size) using 0.01 M potassium dihydrogen o-phosphate (pH 4 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1.5 mL/min. Quantification was achieved by UV detection at 276 nm. The HPTLC separation was achieved on precoated silica gel 60F254 plates using chloroform-methanol-acetonitrile (4 + 2+ 4, v/v/v) mobile phase. Quantification was achieved with UV detection at 276 nm. The UV-Vis spectrophotometric method was based on the simultaneous equation method that involves measurement of absorbance at two wavelengths, i.e., 255 nm (lambda max of OLM) and 246.2 nm (lambda max of ATV) in methanol. All three methods were validated as per International Conference on Harmonization guidelines. The proposed methods were simple, precise, accurate, and applicable for the simultaneous determination of ATV and OLM in a marketed formulation. The results obtained by applying the proposed methods were statistically analyzed and were found satisfactory.

  1. Preparation of a silica stationary phase co-functionalized with Wulff-type phenylboronate and C12 for mixed-mode liquid chromatography.

    PubMed

    Li, Hengye; Zhang, Xuemeng; Zhang, Lin; Wang, Xiaojin; Kong, Fenying; Fan, Dahe; Li, Lei; Wang, Wei

    2017-04-15

    A silica stationary phase was designed and synthesized through the co-functionalization of silica with Wulff-type phenylboronate and C12 for mixed-mode liquid chromatography applications. The as-synthesized stationary phase was characterized by elemental analysis and Fourier Transform-InfraRed Spectroscopy (FT-IR). Retention mechanisms, including boronate affinity (BA), reversed-phase (RP) and anion-exchange (AE), were involved. Retention mechanism switching was easily realized by adjustment of the mobile phase constitution. Cis-diol compounds could be selectively captured under neutral conditions in BA mode and off-line separated in RP mode. Neutral, basic, acidic and amphiprotic compounds were chromatographed on the column in RP chromatography, while inorganic anions were chromatographed in AE chromatography to characterize the mixed-mode nature of the prepared stationary phase. In addition, the RP performance was compared with an octadecyl silica column in terms of column efficiency (N/m), asymmetry factor (A f ), retention factor (k) and resolution (Rs). The prepared stationary phase offered multiple interactions with analytes in addition to hydrophobic interactions under RP elution conditions. Based on the mixed-mode properties, off-line 2D-LC, for selective capture and separation of urinary nucleosides, was successfully realized on a single column, demonstrating its powerful application potential for complex samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Quality evaluation of Yin Chen Hao Tang extract based on fingerprint chromatogram and simultaneous determination of five bioactive constituents.

    PubMed

    Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun

    2008-01-01

    A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.

  3. Characterization of nutraceuticals and functional foods by innovative HPLC methods.

    PubMed

    Corradini, Claudio; Galanti, Roberta; Nicoletti, Isabella

    2002-04-01

    In recent years there is a growing interest in food and food ingredient which may provide health benefits. Food as well as food ingredients containing health-preserving components, are not considered conventional food, but can be defined as functional food. To characterise such foods, as well as nutraceuticals specific, high sensitive and reproducible analytical methodologies are needed. In light of this importance we set out to develop innovative HPLC methods employing reversed phase narrow bore column and high-performance anion-exchange chromatographic methods coupled with pulsed amperometric detection (HPAEC-PAD), which are specific for carbohydrate analysis. The developed methods were applied for the separation and quantification of citrus flavonoids and to characterize fructooligosaccharide (FOS) and fructans added to functional foods and nutraceuticals.

  4. Development and validation of RP-HPLC method: scope of application in the determination of oil solubility of paclitaxel.

    PubMed

    Choudhury, Hira; Gorain, Bapi; Karmakar, Sanmoy; Pal, Tapan Kumar

    2014-01-01

    A simple, reproducible, feasible and innovative reversed-phase high-performance liquid chromatographic method was developed and validated for the quantitative determination of paclitaxel dissolved in various oils. The method was validated after extraction of the analyte from capryol 90, triacetin and olive oil. The method was conducted on a Hypersil BDS C18 column, 250 × 4.6 mm, 5 µm particle size, with a mobile phase composed of acetonitrile: 10 mM KH2PO4 buffer (pH 3.5) (55:45, v/v) and detection at 227 nm. The linearity, in the range of 5 to 50 µg/mL, presented determination coefficients of 0.9983, 0.9997 and 0.9990 in capryol 90, triacetin and olive oil, respectively, calculated by the least-squares regression method. Intra-day precision values for percentages recovered were 0.68 to 0.80, 0.83 to 1.13 and 0.97 to 1.88, and inter day precision values were 1.52 to 1.92, 1.43 to 1.83 and 1.26 to 2.06 for capryol 90, triacetin and olive oil, respectively. The recovery of paclitaxel from the capryol 90, triacetin and olive oil ranged from 97.94 to 103.55, 96.85 to 103.27 and 97.14 to 103.64%, respectively. This developed and validated method was successfully applied to quantitatively assess paclitaxel dissolved in various oils. The solubility of paclitaxel was found to be higher in triacetin than in other tested oils.

  5. Development and validation of two liquid chromatography-tandem mass spectrometry methods for the determination of silibinin and silibinin hemisuccinate in human plasma.

    PubMed

    Sala, Federica; Albares, Pablo; Colovic, Milena; Persiani, Stefano; Rovati, Lucio C

    2014-01-15

    To investigate the pharmacokinetics of silibinin and silibinin hemisuccinate in human plasma, two high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were developed and validated. The methods require a small volume of sample (100μL), and the recovery of the analytes was complete with a good reproducibility (CV% 1.7-9.5), after a simple protein precipitation. Naringenin was used as internal standard. The chromatographic methods provided a good separation of diastereoisomers A and B of both silibinin and silibinin hemisuccinate onto a Chromolith Performance RP18e 100mm×3mm column, with a resolution of peaks from plasma matrix in less than 6min. The methods precision values expressed as CV% were always ≤6.2% and the accuracy was always well within the acceptable 15% range. Quantification was performed on a triple-quadrupole tandem mass spectrometer by Selected Reaction Monitoring (SRM) mode, in a negative ion mode, via electrospray ionization (ESI). The lower limit of quantitation was set at 5.0ng/mL (silibinin) and 25.0ng/mL (silibinin hemisuccinate), and the linearity was validated up to 1000.0 and 12,500.0ng/mL, for silibinin and silibinin hemisuccinate, respectively, with correlation coefficients (R(2)) of 0.991 or better. The methods were suitable for pharmacokinetic studies and were successfully applied to human plasma samples from subjects treated intravenously with Legalon(®) SIL at the dose of 20mg/kg, expressed as silibinin. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples.

    PubMed

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula L N; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one.

  7. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples

    PubMed Central

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula. L. N.; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. PMID:22396907

  8. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  9. [Determination of icaritin in rat plasma by HPLC-MS/MS].

    PubMed

    Liu, Hai-Pei; Meng, Fan-Hua; Guo, Ji-Fen; Si, Duan-Yun; Zhu, Xiao-Wei; Zhao, Yi-Min

    2009-10-01

    The paper is to report the development of a high-performance liquid chromatographic/tandem mass spectrometry (HPLC-MS/MS) method for the determination of icaritin (ICT) in rat plasma. After precipitated with acetonitrile from the plasma, ICT was isolated chromatographically on a Dikma C18 column. The mobile phase consisted of acetonitrile-water-acetic acid (72 : 28 : 1.5, v/v/v). Electrospray ionization (ESI) source was applied and operated in the positive ion mode. Multiple reaction monitoring (MRM) mode with the transitions of m/z 387 --> m/z 313 and m/z 331 --> m/z 315 were used to quantify ICT and the internal standard, respectively. The linear calibration curve was obtained in the concentration range of 2.5-1,000 ng x mL(-1). The lower limit of quantification was 2.5 ng x mL(-1). The inter- and intra-day precision (RSD) were less than 9.63%, and the accuracy (relative error) was within +/-7.42%. The method was proved to be suitable for the pharmacokinetics of ICT, which offers advantages of high sensitivity and selectivity.

  10. Quantitative determination of insulin entrapment efficiency in triblock copolymeric nanoparticles by high-performance liquid chromatography.

    PubMed

    Xu, Xiongliang; Fu, Yao; Hu, Haiyan; Duan, Yourong; Zhang, Zhirong

    2006-04-11

    A rapid and effective isocratic chromatographic procedure was described in this paper for the determination of insulin entrapment efficiency (EE) in triblock copolymeric nanoparticles using reversed-phase high-performance liquid chromatography (RP-HPLC) with an ultraviolet/visible detector at low flow rate. The method has been developed on a Shimadzu Shim-pack VP-ODS column (150 mm x 4.6 mm, 5 microm, Chiyoda-Ku, Tokyo, Japan) using a mixture of 0.2 M sodium sulfate anhydrous solution adjusted to pH 2.3 with phosphoric acid and acetonitrile (73:27, v/v) as mobile phase at the flow rate of 0.8 ml min(-1) and a 214 nm detection. The method was validated in terms of selectivity, linearity, precision, accuracy, solution stability, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was linear in the concentration range of 2.0-500.0 microg ml(-1), and the limits of detection and quantitation were 8 and 20 ng, respectively. The mean recovery of insulin from spiked samples, in a concentration range of 8-100 microg ml(-1), was 98.96% (R.S.D.= 2.51%, n = 9). The intra- and inter-assay coefficients of variation were less than 2.24%. The proposed method has the advantages of simple pretreatment, rapid isolation, high specificity and precision, which can be used for direct analysis of insulin in commercially available raw materials, formulations of nanoparticles, and drug release as well as stability studies.

  11. DETERMINATION OF VENLAFAXINE, VILAZODONE AND THEIR MAIN ACTIVE METABOLITES IN HUMAN SERUM BY HPLC-DAD AND HPLC-MS.

    PubMed

    Petruczynik, Anna; Wroblewski, Karol; Szultka-Mlynska, Malgorzata; Buszewsk, Boguslaw; Karakula-Juchnowicz, Hanna; Gajewski, Jacek; Morylowska-Topolska, Justyna; Waksmundzka-Hajnosi, Monika

    2017-05-01

    A high performance liquid chromatography (HPLC) method for simultaneous analysis of venlafaxine and its major metabolite 0-desmethylvenlafaxine and vilazodone and its methabolite M10 have been devel- oped and validated. Chromatography was performed on the Phenyl-Hexyl column with mobile phase containing methanol, acetate buffer at pH 3.5 and diethylamine. The application of stationary phase with 7r-7c moieties and mobile phase containing diethylamine as silanol blocker lets to obtain double protection against silanols and thus very high theoretical plate numbers were obtained. The good separation selectivity, good peaks' symmetry and very high systems efficiency for all investigated compounds were obtained in applied chromatographic system. The method is very efficient and suitable for the analysis of investigated drugs and their metabolites in human serum for patients' pharmacotherapy control.

  12. Isolation and Structural Characterization of Antioxidant Peptides from Degreased Apricot Seed Kernels.

    PubMed

    Zhang, Haisheng; Xue, Jing; Zhao, Huanxia; Zhao, Xinshuai; Xue, Huanhuan; Sun, Yuhan; Xue, Wanrui

    2018-05-03

    Background : The composition and sequence of amino acids have a prominent influence on theantioxidant activities of peptides. Objective : A series of isolation and purification experiments was conducted to explore the amino acid sequence of antioxidant peptides, which led to its antioxidation causes. Methods : The degreased apricot seed kernels were hydrolyzed by compound proteases of alkaline protease and flavor protease (3:2, u/u) to prepare apricot seed kernel hydrolysates (ASKH). ASKH were separated into ASKH-A and ASKH-B by dialysis bag. ASKH-B (MW < 3.5 kDa) was further separated into fractions by Sephadex G-25 and G-15 gel-filtration chromatography. Reversed-phase HPLC (RP-HPLC) was performed to separate fraction B4b into two antioxidant peptides (peptide B4b-4 and B4b-6). Results : The amino acid sequences were Val-Leu-Tyr-Ile-Trp and Ser-Val-Pro-Tyr-Glu, respectively. Conclusions : The results suggested that ASKH antioxidant peptides may have potential utility as healthy ingredients and as food preservatives due to their antioxidant activity. Highlights : Materials with regional characteristics were selected to explore, and hydrolysates were identified by RP-HPLC and matrix-assisted laser desorption ionization-time-of-flight-MS to obtain amino acid sequences.

  13. Retention behavior of long chain quaternary ammonium homologues and related nitroso-alkymethylamines

    USGS Publications Warehouse

    Abidi, S.L.

    1985-01-01

    Several chromatographic methods have been utilized to study the retentionbehavior of a homologous series of n-alkylbenzyldimethylammonium chlorides (ABDAC) and the corresponding nitroso-n-alkylmethylamines (NAMA). Linear correlation of the logarithmic capacity factor (k') with the number of carbons in the alkyl chain provides useful information on both gas chromatographic (GC) and high-performance liquid chromatographich (HPLC) retention parameters of unknown components. Under all conditions empolyed, GC methodology has proved effective in achieving complete resolution of the homologous mixture of NMA despite its obvious inadequacy in the separation of E-Z configurational isomers. Conversely, normal-phase HPLC on silica demonstrates that the selectivity (a) value for an E-Z pair is much higher than that for an adjacent homologous pair. In the reversed-phase HPLC study, three different silica-based column systems were examined under various mobile phase conditions. The extent of variation in k' was found to be a function of the organic modifier, counter-ion concentration, eluent pH, nature of counter-ion, and the polarity and type of stationary phase. The k'—[NaClO4] profiles showed similar trends between the ABDAC and the NAMA series, supporting the dipolar electronic structures of the latter compounds. Mobile phase and stationary phase effects on component separation are described. The methodology presented establishes the utility of HPLC separation techniques as versatile analytical tools for practical application.

  14. Direct determination of neonicotinoid insecticides in an analytically challenging crop such as Chinese chives using selective ELISAs.

    PubMed

    Watanabe, Eiki; Miyake, Shiro

    2018-06-05

    Easy-to-use commercial kit-based enzyme-linked immunosorbent assays (ELISAs) have been used to detect neonicotinoid dinotefuran, clothianidin and imidacloprid in Chinese chives, which are considered a troublesome matrix for chromatographic techniques. Based on their high water solubility, water was used as an extractant. Matrix interference could be avoided substantially just diluting sample extracts. Average recoveries of insecticides from spiked samples were 85-113%, with relative standard deviation of <15%. The concentrations of insecticides detected from the spiked samples with the proposed ELISA methods correlated well with those by the reference high-performance liquid chromatography (HPLC) method. The residues analyzed by the ELISA methods were consistently 1.24 times that found by the HPLC method, attributable to loss of analyte during sample clean-up for HPLC analyses. It was revealed that the ELISA methods can be applied easily to pesticide residue analysis in troublesome matrix such as Chinese chives.

  15. A New Improved RP-HPLC Method for Assay of Rosuvastatin Calcium in Tablets

    PubMed Central

    Kaila, H. O.; Ambasana, M. A.; Thakkar, R. S.; Saravaia, H. T.; Shah, A. K.

    2010-01-01

    A reliable and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for assay of rosuvastatin calcium in tablets and for determination of content uniformity. An isocratic separation of rosuvastatin calcium was achieved on YMC C8, 150×4.6 mm i.d., 5 μm particle size columns with a flow rate of 1.5 ml/min and using a photodiode array detector to monitor the eluate at 242 nm. The mobile phase consisted of acetonitrile: water (40:60, v/v) pH 3.5 adjusted with phosphoric acid. The drug was subjected to oxidation, hydrolysis, photolysis and thermal degradation. All degradation products in an overall analytical run time of approximately 10 min with the parent compound rosuvastatin eluting at approximately 5.2 min. Response was a linear function of drug concentration in the range of 0.5-80 μg/ml (r2= 0.9993) with a limit of detection and quantification of 0.1 and 0.5 μg/ml respectively. Accuracy (recovery) was between 99.6 and 101.7%. Degradation products resulting from the stress studies did not interfere with the detection of rosuvastatin and the assay is thus stability-indicating. PMID:21694991

  16. Development and validation of a novel stability-indicating HPLC method for the quantitative determination of eleven related substances in ezetimibe drug substance and drug product.

    PubMed

    Luo, Zhiqiang; Deng, Zhongqing; Liu, Yang; Wang, Guopeng; Yang, Wenning; Hou, Chengbo; Tang, Minming; Yang, Ruirui; Zhou, Huaming

    2015-07-01

    Ezetimibe is a novel lipid-lowering agent that inhibits intestinal absorption of dietary and biliary cholesterol. In the present work, a simple, sensitive and reproducible gradient reverse phase high performance liquid chromatographic (RP-HPLC) method for separation and determination of the related substances of ezetimibe was developed and validated. Eleven potential process-related impurities (starting materials, (3S,4S,3'S)-isomer, degradants and byproducts) were identified in the crude samples. Tentative structures for all the impurities were assigned primarily based on comparison of their retention time and mass spectrometric data with that of available standards and references. This method can be applied to routine analysis in quality control of both bulk drugs and commercial tablets. Separation of all these compounds was performed on a Phenomenex Luna Phenyl-Hexyl (100mm×4.6mm, 5μm) analytical column. The mobile phase-A consists of acetonitrile-water (pH adjusted to 4.0 with phosphoric acid)-methanol at 15:75:10 (v/v/v), and mobile phase-B contains acetonitrile. The eluted compounds were monitored at 210nm. Ezetimibe was subjected to hydrolytic, acid, base, oxidative, photolytic and thermal stress conditions as per ICH serves to generate degradation products that can be used as a worst case to assess the analytical method performance. The drug showed extensive degradation in thermal, acid, oxidative, base and hydrolytic stress conditions, while it was stable to photolytic degradation conditions. The main degradation product formed under thermal, acid, oxidative, base and hydrolytic stress conditions corresponding to (2R,3R,6S)-N, 6-bis(4-fluorophenyl)-2-(4-hydroxyphenyl)-oxane-3-carboxamide (Ezetimibe tetrahydropyran impurity) was characterized by LC-MS/MS analysis. The degradation products were well resolved from the main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Quantitative high-performance liquid chromatography of nucleosides in biological materials.

    PubMed

    Gehrke, C W; Kuo, K C; Davis, G E; Suits, R D; Waalkes, T P; Borek, E

    1978-03-21

    A rigorous, comprehensive, and reliable reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the analysis of ribonucleosides in urine (psi, m1A, m1I, m2G, A, m2(2)G). An initial isolation of ribonucleosides with an affinity gel containing an immobilized phenylboronic acid was used to improve selectivity and sensitivity. Response for all nucleosides was linear from 0.1 to 50 nmoles injected and good quantitation was obtained for 25 microliter or less of sample placed on the HPLC column. Excellent precision of analysis for urinary nucleosides was achieved on matrix dependent and independent samples, and the high resolution of the reversed-phase column allowed the complete separation of 9 nucleosides from other unidentified UV absorbing components at the 1-ng level. Supporting experimental data are presented on precision, recovery, chromatographic methods, minimum detection limit, retention time, relative molar response, sample clean-up, stability of nucleosides, boronate gel capacity, and application to analysis of urine from patients with leukemia and breast cancer. This method is now being used routinely for the determination of the concentration and ratios of nucleosides in urine from patients with different types of cancer and in chemotherapy response studies.

  18. Analysis of residual products in triethylbenzylammonium chloride by HPLC. Study of the retention mechanism.

    PubMed

    Prieto-Blanco, M C; López-Mahía, P; Prada-Rodríguez, D

    2006-04-01

    The control of industrial products for minimization of their impact on the environment and human health requires the development of specific analysis methods. Information provided by these methods about toxic components, by-products, and other derivatives may also be useful to reduce the possible impact of industrial products. The studied compound in this paper, triethylbenzylammonium chloride (TEBA), is mainly used in industrial synthesis. This quaternary compound and its residual products coming from quaternization reaction (benzyl chloride, benzaldehyde, and benzyl alcohol) are analyzed by HPLC. The separation is based on control of the silanophilic contribution to TEBA retention because of the quaternary nature of this compound. The effect of the three buffers (sodium acetate, ammonium acetate, and sodium formate) and their concentrations in the chromatographic behavior of the quaternary compound is examined. The buffer cation and anion regulate TEBA retention. Also, the concentration of the quaternary compound is another parameter that had influence in some aspects of its chromatographic behavior (e.g., retention and symmetry). The proposed method is applied to TEBA synthesis along, with the formation and removal of impurities with the results compared with those obtained for the quaternary compound benzalkonium chloride.

  19. The integrated quality assessment of Chinese commercial dry red wine based on a method of online HPLC-DAD-CL combined with HPLC-ESI-MS.

    PubMed

    Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin

    2014-07-01

    To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  20. HPLC SEPARATION OF CHIRAL ORGANOPHOSPHORUS PESTICIDES ON POLYSACCHARIDE CHIRAL STATIONARY PHASES

    EPA Science Inventory

    High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) were obtained on polysaccharide chiral HPLC columns using an alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, dyfonate, fenamiphos, ...

  1. A rapid solid-phase extraction method for measurement of non-metabolised peripheral benzodiazepine receptor ligands, [(18)F]PBR102 and [(18)F]PBR111, in rat and primate plasma.

    PubMed

    Katsifis, Andrew; Loc'h, Christian; Henderson, David; Bourdier, Thomas; Pham, Tien; Greguric, Ivan; Lam, Peter; Callaghan, Paul; Mattner, Filomena; Eberl, Stefan; Fulham, Michael

    2011-01-01

    To develop a rapid and reliable method for estimating non-metabolised PBR ligands fluoroethoxy ([(18)F]PBR102)- and fluoropropoxy ([(18)F]PBR111)-substituted 2-(6-chloro-2-phenyl)imidazo[1,2-a]pyridine-3-yl)-N,N-diethylacetamides in plasma. Rats and baboons were imaged with PET up to 2 h postinjection of [(18)F]PBR102 and [(18)F]PBR111 under baseline conditions, after pre-blocking or displacement with PK11195. Arterial plasma samples were directly analysed by reverse-phase solid-phase extraction (RP-SPE) and RP-HPLC and by normal-phase TLC. SPE cartridges were successively washed with acetonitrile/water mixtures. SPE eluant radioactivity was measured in a γ-counter to determine the parent compound fraction and then analysed by HPLC and TLC for validation. In SPE, hydrophilic and lipophilic radiolabelled metabolites were eluted in water and 20% acetonitrile/water. All non-metabolised [(18)F]PBR102 and [(18)F]PBR111 were in SPE acetonitrile fraction as confirmed by HPLC and TLC analysis. Unchanged (%) [(18)F]PBR102 and [(18)F]PBR111 from SPE analysis in rat and baboon plasma agreed with those from HPLC and TLC analysis. In rats and baboons, the fraction of unchanged tracer followed a bi-exponential decrease, with half-lives of 7 to 10 min for the fast component and >80 min for the slow component for both tracers. Direct plasma SPE analysis of [(18)F]PBR102 and [(18)F]PBR111 can reliably estimate parent compound fraction. SPE was superior to HPLC for samples with low activity; it allows rapid and accurate metabolite analysis of a large number of plasma samples for improved estimation of metabolite-corrected input function during quantitative PET imaging studies. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  2. Biodiversity of Salix spp. honeydew and nectar honeys determined by RP-HPLC and evaluation of their antioxidant capacity.

    PubMed

    Tuberoso, Carlo I G; Jerković, Igor; Bifulco, Ersilia; Marijanović, Zvonimir

    2011-05-01

    Rare unifloral willow (Salix spp.) honeys obtained from nectar or honeydew were investigated by direct RP-HPLC-DAD method in order to identify and quantify compounds that can be used as possible markers of their origin. Antioxidant and antiradical activities of willow honeys were evaluated using FRAP (=ferric reducing antioxidant assay) and DPPH (=1,1-diphenyl-2-picrylhydrazyl radical) tests, respectively. Also HMF (=5-(hydroxymethyl)furfural), diastase activity, and CIE L*a*b*C*h* chromatic coordinates were evaluated. Abscisic acids (ABA) are typical of willow nectar honey, with a predominance of (Z,E)-ABA on (E,E)-ABA (98.2 and 31.7 mg/kg, resp.). Kinurenic acid and salicylic acid are useful to mark willow honeydew honey. The proposed HPLC-DAD method proved to be easy and reliable to identify the two different Salix spp. honeys, being not affected from any sample preparation artifact. Total antioxidant activity measured with the FRAP assay ranged from 3.2 to 12.6 mmol Fe(2+) /kg, and the antiradical activity measured with the DPPH assay ranged from 0.6 to 3.0 mmol TEAC (=Trolox equivalent antioxidant capacity)/kg in nectar and honeydew honeys, respectively. Salix spp. nectar and honeydew honeys proved to be two completely different honeys, because, besides color attributes, they show different antioxidant properties and specific compounds. Copyright © 2011 Verlag Helvetica Chimica Acta AG, Zürich.

  3. Annotation of the human serum metabolome by coupling three liquid chromatography methods to high-resolution mass spectrometry.

    PubMed

    Boudah, Samia; Olivier, Marie-Françoise; Aros-Calt, Sandrine; Oliveira, Lydie; Fenaille, François; Tabet, Jean-Claude; Junot, Christophe

    2014-09-01

    This work aims at evaluating the relevance and versatility of liquid chromatography coupled to high resolution mass spectrometry (LC/HRMS) for performing a qualitative and comprehensive study of the human serum metabolome. To this end, three different chromatographic systems based on a reversed phase (RP), hydrophilic interaction chromatography (HILIC) and a pentafluorophenylpropyl (PFPP) stationary phase were used, with detection in both positive and negative electrospray modes. LC/HRMS platforms were first assessed for their ability to detect, retain and separate 657 metabolite standards representative of the chemical families occurring in biological fluids. More than 75% were efficiently retained in either one LC-condition and less than 5% were exclusively retained by the RP column. These three LC/HRMS systems were then evaluated for their coverage of serum metabolome. The combination of RP, HILIC and PFPP based LC/HRMS methods resulted in the annotation of about 1328 features in the negative ionization mode, and 1358 in the positive ionization mode on the basis of their accurate mass and precise retention time in at least one chromatographic condition. Less than 12% of these annotations were shared by the three LC systems, which highlights their complementarity. HILIC column ensured the greatest metabolome coverage in the negative ionization mode, whereas PFPP column was the most effective in the positive ionization mode. Altogether, 192 annotations were confirmed using our spectral database and 74 others by performing MS/MS experiments. This resulted in the formal or putative identification of 266 metabolites, among which 59 are reported for the first time in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. A bridging study for oxytetracycline in the edible fillet of rainbow trout: Analysis by a liquid chromatographic method and the official microbial inhibition assay

    USGS Publications Warehouse

    Stehly, G.R.; Gingerich, W.H.; Kiessling, C.R.; Cutting, J.H.

    1999-01-01

    Oxytetracycline (OTC) is a drug approved by the U.S. Food and Drug Administration (FDA) to control certain diseases in salmonids and catfish. OTC is also a likely control agent for diseases of other fish species and for other diseases of salmonids and catfish not currently on the label. One requirement for FDA to extend and expand the approval of this antibacterial agent to other fish species is residue depletion studies. The current regulatory method for OTC in fish tissue, based on microbial inhibition, lacks sensitivity and specificity. To conduct residue depletion studies for OTC in fish with a liquid chromatographic method, a bridging study was required to determine its relationship with the official microbial inhibition assay. Triplicate samples of rainbow trout fillet tissue fortified with OTC at 0.3, 0.6, 1.2, 2.4, 4.8, and 9.6 ppm and fillet tissue with incurred OTC at approximately 0.75, 1.5, and 3.75 ppm were analyzed by high-performance liquid chromatography (HPLC) and the microbial inhibition assay. The results indicated that the 2 methods are essentially identical in the tested range, with mean coefficients of variation of 1.05% for the HPLC method and 3.94% for the microbial inhibition assay.

  5. Dissemination of the highly expressed Bx7 glutenin subunit (Glu-B1al allele) in wheat as revealed by novel PCR markers and RP-HPLC.

    PubMed

    Butow, B J; Gale, K R; Ikea, J; Juhász, A; Bedö, Z; Tamás, L; Gianibelli, M C

    2004-11-01

    Increased expression of the high molecular weight glutenin subunit (HMW-GS) Bx7 is associated with improved dough strength of wheat (Triticum aestivum L.) flour. Several cultivars and landraces of widely different genetic backgrounds from around the world have now been found to contain this so-called 'over-expressing' allelic form of the Bx7 subunit encoded by Glu-B1al. Using three methods of identification, SDS-PAGE, RP-HPLC and PCR marker analysis, as well as pedigree information, we have traced the distribution and source of this allele from a Uruguayan landrace, Americano 44D, in the mid-nineteenth century. Results are supported by knowledge of the movement of wheat lines with migrants. All cultivars possessing the Glu-B1al allele can be identified by the following attributes: (1) the elution of the By sub-unit peak before the Dx sub-unit peak by RP-HPLC, (2) high expression levels of Bx7 (>39% Mol% Bx), (3) a 43 bp insertion in the matrix-attachment region (MAR) upstream of the gene promoter relative to Bx7 and an 18 bp nucleotide duplication in the coding region of the gene. Evidence is presented indicating that these 18 and 43 bp sequence insertions are not causal for the high expression levels of Bx7 as they were also found to be present in a small number of hexaploid species, including Chinese Spring, and species expressing Glu-B1ak and Glu-B1a alleles. In addition, these sequence inserts were found in different isolates of the tetraploid wheat, T. turgidum, indicating that these insertion/deletion events occurred prior to hexaploidization.

  6. Simultaneous determination of amlodipine and bisoprolol in rat plasma by a liquid chromatography/tandem mass spectrometry method and its application in pharmacokinetic study.

    PubMed

    Chang, Huichao; Li, Jinyin; Li, Ji; Guan, Xiaoduo; Sun, Fanlu; Qian, Zhongzhi; Bi, Kaishun; Fan, Guorong

    2012-12-01

    A sensitive, specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was established for the quantitative determination of amlodipine and bisoprolol, using clenbuterol as the internal standard (IS). The analytes and IS were isolated from 100μL plasma samples by a simple liquid-liquid extraction (LLE). Reverse-phase high performance liquid chromatography (RP-HPLC) separation was accomplished on a Diamonsil C(18) column (50mm×4.6mm, 5μm) with a mobile phase composed of methanol-water-formic acid (75:25:0.01, v/v/v) at a flow rate of 0.3mL/min. The method had a chromatographic total run time of 3min. Multiple reacting monitoring (MRM) transitions of m/z [M+H](+) 409.1→237.9 (amlodipine), m/z [M+H](+) 326.2→116.0 (bisoprolol) and m/z [M+H](+) 277.0→203.0 (clenbuterol, IS) were used to quantify amlodipine, bisoprolol and IS, respectively. The method was sensitive with a lower limit of quantitation (LLOQ) of 0.2ng/mL for both amlodipine and bisoprolol, and the linear range was 0.2-50ng/mL for both amlodipine and bisoprolol (r(2)>0.9961). All the validation data, such as accuracy, precision and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic studies of amlodipine and bisoprolol in Sprague-Dawley (SD) rats. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Identification and Structure Elucidation of Forced Degradation Products of the Novel Propionic acid Derivative Loxoprofen: Development of Stability-Indicating Chromatographic Methods Validated as per ICH Guidelines.

    PubMed

    Eissa, Maya S; Abd El-Sattar, Osama I

    2017-04-01

    Loxoprofen sodium (LOX) is a recently developed novel propionic acid derivative. Owing to its instability under both hydrolytic and oxidative conditions, the development of simple, rapid and sensitive methods for its determination in the presence of its possible forced degradation products becomes essential. Two simple chromatographic methods, high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC), were developed associated with ultraviolet (UV) detection. In HPTLC-densitometric method, the separation of LOX from its degradation products was achieved using silica gel F254 plates and toluene:acetone:acetic acid (1.8:1.0:0.1, v/v/v) as the developing system followed by densitometric scanning at 220 nm. In the HPLC-UV method, the separation was performed using isocratic elution system with acetonitrile: 0.15% triethylamine (pH 2.2) (50:50, v/v) on C18 analytical column. The flow rate was optimized at 1.0 mL·min-1 and UV detection was achieved at 220 nm. Validation was performed in accordance with the International Conference on Harmonization guidelines and the method was perfectly applied for determination of LOX in its pharmaceutical preparation. The results obtained were statistically compared to those obtained after application of the official HPLC method, where no significant difference was found incompliance with precision and accuracy. Identification and characterization of the possible hydrolytic degradation product under alkaline conditions and that produced during oxidative degradation using hydrogen peroxide were structurally elucidated using infrared and mass spectrometry analyses. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. [Simultaneous determination of five active constitutents in Xiaochaihu Tang by HPLC].

    PubMed

    Liu, Qingchun; Zhao, Junning; Yan, Liangchun; Yi, Jinhai; Song, Jun

    2010-03-01

    To establish a HPLC-PDA method for the determination of baicalin, wogonoside, baicalein, wogonin and glycyrrhizic acid in Xiaochaihu Tang. A Symmetry Shield RP18 (4.6 mm x 250 mm, 5.0 microm) was used with a mobile phase of acetonitrile-0.01% H3PO4 in gradient elution. The detection wavelength was 251 nm,the flow rate was 0.45 mL x min(-1) and the column temperature was maintained at 30 degrees C. The accuracy, precision, sensitivity, specificity and linearity of this method met the requirements. The contents of the five effective fractions were determined simultaneously. The method is rapid,simple and accurate and it can be suitable for the determination of baicalin, wogonoside, baicalein, wogonin and glycyrrhizic acid in Xiaochaihu Tang simultaneously.

  9. HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF ORGANOPHOSPHORUS PESTICIDES ON POLYSACCHARIDE CHIRAL STATIONARY PHASES

    EPA Science Inventory

    High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) was obtained on polysaccharide enantioselective HPLC columns using alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, fonofos, fenamiph...

  10. [Immuno-affinity chromatographic purification: the study of methods to test citrinin in monascus products by high performance liquid chromatography].

    PubMed

    Qiu, Wen-qian; Liu, Xiao-xia; Zheng, Kui-cheng; Fu, Wu-sheng

    2012-08-01

    To establish a method to test citrinin (CIT) in monascus products by immuno-affinity chromatography (IAC)-high performance liquid chromatography (HPLC), and to detect the content of CIT in monascus products in Fujian province. IAC-HPLC was applied to detect the CIT content in monascus products. The conditions to use HPLC were as follows: C(18) reversed-phase chromatographic column, 150.0 mm×4.6mm×3 µm; mobile phase: the volume ratio of acetonitrile and 0.1% phosphoric acid solution at 65:35; isocratic elution; column temperature: 28°C; flow velocity: 0.8 ml/min; fluorescence detector, excitation wavelength (λ(ex)) was 331 nm and emission wavelength (λ(em)) was 500 nm. The standard curved was established by the linear regression of peak area (Y) to CIT content (X, ng/ml). The accuracy and precision of the method would then be verified. And 32 kinds of monascus products were determined and their color values were compared by this method. The standard curve established in this study was Y = 4634.8X-136.42, r = 1.000; whose limits of detection was 20 µg/kg and the limits of qualification was 64 µg/kg. In the range between 200 and 800 µg/kg, the standard recovery rate was 98.9% - 110.0% (n = 3), and the relative standard deviation (RSD) was 0.51% - 1.76%. Out of the 32 samples, CIT was detected from 11 samples of monascus rice, 9 samples of monascus powder and 5 samples of monascus pigments, the content was around 0.212 - 14.500 mg/kg. 4 out of 7 functional monascus samples were detected out CIT, whose content at 0.142 - 0.275 mg/kg. The method to detect CIT in monascus products by IAC-HPLC has been established.

  11. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    PubMed Central

    Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R2) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R2 > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0–103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5–20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition. PMID:25452691

  12. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method.

    PubMed

    Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition.

  13. Novel surface modification of polymer-based separation media controlling separation selectivity, retentivity and generation of electroosmotic flow.

    PubMed

    Hosoya, Ken; Kubo, Takuya; Takahashi, Katsuo; Ikegami, Tohru; Tanaka, Nobuo

    2002-12-06

    Uniformly sized packing materials based on synthetic polymer particles for high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) have been prepared from polymerization mixtures containing methacrylic acid (MAA) as a functional monomer and by using a novel surface modification method. This "dispersion method" affords effectively modified separation media. Both the amount of MAA utilized in the preparation and reaction time affect the selectivity of chromatographic separation in both the HPLC and the CEC mode and electroosmotic flow. This detailed study revealed that the dispersion method effectively modified internal surface of macroporous separation media and, based on the amount of MAA introduced, exclusion mechanism for the separation of certain solutes could be observed.

  14. Determination of 30 synthetic food additives in soft drinks by HPLC/electrospray ionization-tandem mass spectrometry.

    PubMed

    Gao, Hui; Yang, Minli; Wang, Minglin; Zhao, Yansheng; Cao, Ya; Chu, Xiaogang

    2013-01-01

    A method combining SPE with HPLC/electrospray ionization-MS/MS was developed for simultaneous determination of 30 synthetic food additives, including synthetic colorants, preservatives, and sweeteners in soft drinks. All targets were efficiently separated using the optimized chromatographic and MS conditions and parameters in a single run within 18 min. The LOD of the analytes ranged from 0.01 to 20 microg/kg, and the method was validated with recoveries in the 80.8 to 106.4% range. This multisynthetic additive method was found to be accurate and reliable and will be useful to ensure the safety of food products, such as the labeling and proper use of synthetic food additives in soft drinks.

  15. Development and application of a high-performance liquid chromatography method using monolithic columns for the analysis of ecstasy tablets.

    PubMed

    Mc Fadden, Kim; Gillespie, John; Carney, Brian; O'Driscoll, Daniel

    2006-07-07

    A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.

  16. An HPLC method for determination of azadirachtin residues in bovine muscle.

    PubMed

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  17. HPLC and LC-MS/MS methods for determination of sodium benzoate and potassium sorbate in food and beverages: performances of local accredited laboratories via proficiency tests in Turkey.

    PubMed

    Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan

    2015-05-15

    High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Syn/anti isomerization of 2,4-dinitrophenylhydrazones in the determination of airborne unsymmetrical aldehydes and ketones using 2,4-dinitrophenylhydrazine derivation.

    PubMed

    Binding, N; Müller, W; Witting, U

    1996-10-01

    Aldehydes and ketones readily react with 2,4-dinitrophenylhydrazine (2,4-DNPH) to form the corresponding hydrazones. This reaction has been frequently used for the quantification of airborne carbonyl compounds. Since unsymmetrical aldehydes and ketones are known to form isomeric 2,4-dinitrophenylhydrazones (syn/ anti-isomers), the influence of isomerization on the practicability and accuracy of the 2,4-DNPH-method using 2,4-dinitrophenylhydrazine-coated solid sorbent samplers has been studied with three ketones (methyl ethyl ketone (MEK), methyl isopropyl ketone (MIPK), and methyl isobutyl ketone (MIBK)). With all three ketones the reaction with 2,4-DNPH resulted in mixtures of the isomeric hydrazones which were separated by HPLC and GC and identified by mass spectroscopy and (1)H nuclear magnetic resonance spectroscopy. The isomers show similar chromatographic behaviour in HPLC as well as in GC, thus leading to problems in quantification and interpretation of chromatographic results.

  19. Analytical method development and validation of simultaneous estimation of rabeprazole, pantoprazole, and itopride by reverse-phase high-performance liquid chromatography.

    PubMed

    Perumal, Senthamil Selvan; Ekambaram, Sanmuga Priya; Raja, Samundeswari

    2014-12-01

    A simple, selective, rapid, and precise reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of rabeprazole (RP), pantoprazole (PP), and itopride (IP) has been developed. The compounds were well separated on a Phenomenex C 18 (Luna) column (250 mm × 4.6 mm, dp = 5 μm) with C 18 guard column (4 mm × 3 mm × 5 μm) with a mobile phase consisting of buffer containing 10 mM potassium dihydrogen orthophosphate (adjusted to pH 6.8): acetonitrile (70:30 v/v) at a flow rate of 1.0 mL/min and ultraviolet detection at 288 nm. The retention time of RP, PP, and IP were 5.35, 7.92, and 11.16 minutes, respectively. Validation of the proposed method was carried out according to International Conference on Harmonisation (ICH) guidelines. Linearity range was obtained for RP, PP, and IP over the concentration range of 2.5-25, 1-30, and 3-35 μg/mL and the r 2 values were 0.994, 0.978, and 0.991, respectively. The calculated limit of detection (LOD) values were 1, 0.3, and 1 μg/mL and limit of quantitation (LOQ) values were 2.5, 1, and 3 μg/mL for RP, PP, and IP correspondingly. Thus, the current study showed that the developed reverse-phase liquid chromatography method is sensitive and selective for the estimation of RP, PP, and IP in combined dosage form. Copyright © 2014. Published by Elsevier B.V.

  20. LIQUID CHROMATOGRAPHY DETERMINATION OF ANTI-ANDROGEN VINCLOZOLIN AND ITS METABOLITES IN RAT SERUM

    EPA Science Inventory

    The objective of this study was to develop a chromatographic method for the analysis of the anti-androgen vinclozolin (V) and its butenoic acid (M1) and enanilide (M2) metabolites in rat serum. V, M1, M2 and M3 were resolved using an HPLC gradient program with a mobile phase con...

  1. HPLC study on the 'history' dependence of gramicidin A conformation in phospholipid model membranes.

    PubMed

    Bañó, M C; Braco, L; Abad, C

    1989-06-19

    A novel HPLC methodology for the study of gramicidin A reconstituted in model membranes has been tested in comparison with circular dichroism data. It is shown that this chromatographic technique not only corroborates most of the recent spectroscopic results but allows one to explain them in terms of mass fractions of different actual conformational species of GA in the phospholipid assemblies. In particular, the dependence of the inserted peptide configuration on the organic solvent and other parameters involved in the 'history' of the sample preparation and handling has been analyzed by HPLC in two phospholipid model systems: small unilamellar vesicles and micelles. Moreover, a slow conformational transition of GA towards a beta 6.3-helical configuration, accelerated by heat incubation, has been also chromatographically visualized and quantitatively interpreted.

  2. HPLC-based quantification of bacterial housekeeping nucleotides and alarmone messengers ppGpp and pppGpp.

    PubMed

    Varik, Vallo; Oliveira, Sofia Raquel Alves; Hauryliuk, Vasili; Tenson, Tanel

    2017-09-08

    Here we describe an HPLC-based method to quantify bacterial housekeeping nucleotides and the signaling messengers ppGpp and pppGpp. We have replicated and tested several previously reported HPLC-based approaches and assembled a method that can process 50 samples in three days, thus making kinetically resolved experiments feasible. The method combines cell harvesting by rapid filtration, followed by acid extraction, freeze-drying with chromatographic separation. We use a combination of C18 IPRP-HPLC (GMP unresolved and co-migrating with IMP; GDP and GTP; AMP, ADP and ATP; CTP; UTP) and SAX-HPLC in isocratic mode (ppGpp and pppGpp) with UV detection. The approach is applicable to bacteria without the requirement of metabolic labelling with 32P-labelled radioactive precursors. We applied our method to quantify nucleotide pools in Escherichia coli BW25113 K12-strain both throughout the growth curve and during acute stringent response induced by mupirocin. While ppGpp and pppGpp levels vary drastically (40- and ≥8-fold, respectively) these changes are decoupled from the quotients of the housekeeping pool and guanosine and adenosine housekeeping nucleotides: NTP/NDP/NMP ratio remains stable at 6/1/0.3 during both normal batch culture growth and upon acute amino acid starvation.

  3. Quantitation of polymethoxylated flavones in orange juice by high-performance liquid chromatography.

    PubMed

    Rouseff, R L; Ting, S V

    1979-08-01

    A quantitative high-performance liquid chromatographic (HPLC) procedure for the determination of the five major polymethoxylated flavones (PMFs) in orange juice has been developed. It employs a unique ternary solvent system with coupled UV-fluorescence detection. The dual detectors were employed to determine the presence of interfering substances and served as a cross check on quantitation. Stop flow UV and fluorescence scanning was used to identify peaks and determine the presence of impurities. Although all five citrus PMFs fluoresce, some HPLC fluorescence peaks were too small to be of much practical use. All five citrus PMFs could be quantitated satisfactorily with the fixed wavelength UV (313 nm) detector. The HPLC procedure has been used to evaluate each step in the preparation. The optimum extracting solvent was selected and one time consuming step was eliminated, as it was found to be unnecessary. HPLC values for nobiletin and sinensetin are in good agreement with the thin-layer chromatographic (TLC) values in the literature. HPLC values for the other three flavones were considerably lower than those reported in the literature. The HPLC procedure is considerably faster than the TLC procedure with equal or superior precision and accuracy.

  4. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.

    PubMed

    Patyra, E; Kowalczyk, E; Grelik, A; Przeniosło-Siwczyńska, M; Kwiatek, K

    2015-01-01

    A liquid chromatography - diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid - acetonitrile - methanol at 30°C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CCα), detection capacity (CCβ), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 μg/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.

  6. Chromatographic-ICPMS methods for trace element and isotope analysis of water and biogenic calcite

    NASA Astrophysics Data System (ADS)

    Klinkhammer, G. P.; Haley, B. A.; McManus, J.; Palmer, M. R.

    2003-04-01

    ICP-MS is a powerful technique because of its sensitivity and speed of analysis. This is especially true for refractory elements that are notoriously difficult using TIMS and less energetic techniques. However, as ICP-MS instruments become more sensitive to elements of interest they also become more sensitive to interference. This becomes a pressing issue when analyzing samples with high total dissolved solids. This paper describes two trace element methods that overcome these problems by using chromatographic techniques to precondition samples prior to analysis by ICP-MS: separation of rare earth elements (REEs) from seawater using HPLC-ICPMS, and flow-through dissolution of foraminiferal calcite. Using HPLC in combination with ICP-MS it is possible to isolate the REEs from matrix, other transition elements, and each other. This method has been developed for small volume samples (5ml) making it possible to analyze sediment pore waters. As another example, subjecting foram shells to flow-through reagent addition followed by time-resolved analysis in the ICP-MS allows for systematic cleaning and dissolution of foram shells. This method provides information about the relationship between dissolution tendency and elemental composition. Flow-through is also amenable to automation thus yielding the high sample throughput required for paleoceanography, and produces a highly resolved elemental matrix that can be statistically analyzed.

  7. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. I. A thermodynamic perspective.

    PubMed

    Åsberg, Dennis; Leśko, Marek; Samuelsson, Jörgen; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2014-10-03

    This is the first investigation in a series that aims to enhance the scientific knowledge needed for reliable analytical method transfer between HPLC and UHPLC using the quality by design (QbD) framework. Here, we investigated the differences and similarities from a thermodynamic point of view between RP-LC separations conducted with 3.5μm (HPLC) and 1.7μm (UHPLC) C18 particles. Three different model solutes and one pharmaceutical compound were used: the uncharged cycloheptanone, the cationic benzyltriethylammonium chloride, the anionic sodium 2-naphatlene sulfonate and the pharmaceutical compound omeprazole, which was anionic at the studied pH. Adsorption data were determined for the four solutes at varying fractions of organic modifier and in gradient elution in both the HPLC and UHPLC system, respectively. From the adsorption data, the adsorption energy distribution of each compound was calculated and the adsorption isotherm model was estimated. We found that the adsorption energy distribution was similar, with only minor differences in degree of homogeneity, for HPLC and UHPLC stationary phases. The adsorption isotherm model did not change between HPLC and UHPLC, but the parameter values changed considerably especially for the ionic compounds. The dependence of the organic modifier followed the same trend in HPLC as in UHPLC. These results indicates that the adsorption mechanism of a solute is the same on HPLC and UHPLC stationary phases which simplifies design of a single analytical method applicable to both HPLC and UHPLC conditions within the QbD framework. Copyright © 2014. Published by Elsevier B.V.

  8. Quantification of allantoin in various Zea mays L. hybrids by RP-HPLC with UV detection.

    PubMed

    Maksimović, Z; Malenović, A; Jancić, B; Kovacević, N

    2004-07-01

    A RP-HPLC method for quantification of allantoin in silk of fifteen maize hybrids (Zea mays L., Poaceae) was described. Following extraction of the plant material with an acetone-water (7:3, VN) mixture, filtration and dilution, the extracts were analyzed without previous chemical derivatization. Separation and quantification were achieved using an Alltech Econosil C18 column under isocratic conditions at 40 degrees C. The mobile phase flow (20% methanol--80% water with 5 mM sodium laurylsulfate added at pH 2.5, adjusted with 85% orthophosphoric acid; pH of water phase was finally adjusted at 6.0 by addition of triethylamine) was maintained at 1.0 mL/min. Column effluent was monitored at 235 nm. This simple procedure afforded efficient separation and quantification of allantoin in plant material, without interference of polyphenols or other plant constituents of medium to high polarity, or similar UV absorption. Our study revealed that the silk of all investigated maize hybrids could be considered relatively rich in allantoin, covering the concentration range between 215 and 289 mg per 100 g of dry plant material.

  9. Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications.

    PubMed

    Aral, Tarık; Aral, Hayriye; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep

    2015-01-01

    A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 µm, 60 Å). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20°C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 230 or 278 nm. The best separation conditions for seven phenolic compounds was also achieved using reversed-phase HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and seven phenolic compounds could be separated and detected at 230 nm within 16 min. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Fast-HPLC Fingerprinting to Discriminate Olive Oil from Other Edible Vegetable Oils by Multivariate Classification Methods.

    PubMed

    Jiménez-Carvelo, Ana M; González-Casado, Antonio; Pérez-Castaño, Estefanía; Cuadros-Rodríguez, Luis

    2017-03-01

    A new analytical method for the differentiation of olive oil from other vegetable oils using reversed-phase LC and applying chemometric techniques was developed. A 3 cm short column was used to obtain the chromatographic fingerprint of the methyl-transesterified fraction of each vegetable oil. The chromatographic analysis took only 4 min. The multivariate classification methods used were k-nearest neighbors, partial least-squares (PLS) discriminant analysis, one-class PLS, support vector machine classification, and soft independent modeling of class analogies. The discrimination of olive oil from other vegetable edible oils was evaluated by several classification quality metrics. Several strategies for the classification of the olive oil were used: one input-class, two input-class, and pseudo two input-class.

  11. Leukotriene B4 catabolism: quantitation of leukotriene B4 and its omega-oxidation products by reversed-phase high-performance liquid chromatography.

    PubMed

    Shak, S

    1987-01-01

    LTB4 and its omega-oxidation products may be rapidly, sensitively, and specifically quantitated by the methods of solid-phase extraction and reversed-phase high-performance liquid chromatography (HPLC), which are described in this chapter. Although other techniques, such as radioimmunoassay or gas chromatography-mass spectrometry, may be utilized for quantitative analysis of the lipoxygenase products of arachidonic acid, only the technique of reversed-phase HPLC can quantitate as many as 10 metabolites in a single analysis, without prior derivatization. In this chapter, we also reviewed the chromatographic theory which we utilized in order to optimize reversed-phase HPLC analysis of LTB4 and its omega-oxidation products. With this information and a gradient HPLC system, it is possible for any investigator to develop a powerful assay for the potent inflammatory mediator, LTB4, or for any other lipoxygenase product of arachidonic acid.

  12. [Comparison study of different methods for extracting volatile oil from bergamot].

    PubMed

    Chen, Fei; Li, Qun-li; Sheng, Liu-qing; Qiu, Jiao-ying

    2008-08-01

    To test different methods for extracting volatile oil from bergamot. The determination of bergapten was carried out by RP-HPLC. Four different ways of organic solvent extraction, steam-input distillation, distillation of the material mixed with water and press extraction were compared. Bergapten wasnt extracted by ways of steam-input distillation and distillation of the material mixed with water. The steam distillation extraction can be taken to extract volatile oil from bergamot for protecting humans' skins.

  13. Evaluation of the suitability of chromatographic systems to predict human skin permeation of neutral compounds.

    PubMed

    Hidalgo-Rodríguez, Marta; Soriano-Meseguer, Sara; Fuguet, Elisabet; Ràfols, Clara; Rosés, Martí

    2013-12-18

    Several chromatographic systems (three systems of high-performance liquid chromatography and two micellar electrokinetic chromatography systems) besides the reference octanol-water partition system are evaluated by a systematic procedure previously proposed in order to know their ability to model human skin permeation. The precision achieved when skin-water permeability coefficients are correlated against chromatographic retention factors is predicted within the framework of the solvation parameter model. It consists in estimating the contribution of error due to the biological and chromatographic data, as well as the error coming from the dissimilarity between the human skin permeation and the chromatographic systems. Both predictions and experimental tests show that all correlations are greatly affected by the considerable uncertainty of the skin permeability data and the error associated to the dissimilarity between the systems. Correlations with much better predictive abilities are achieved when the volume of the solute is used as additional variable, which illustrates the main roles of both lipophilicity and size of the solute to penetrate through the skin. In this way, the considered systems are able to give precise estimations of human skin permeability coefficients. In particular, the HPLC systems with common C18 columns provide the best performances in emulating the permeation of neutral compounds from aqueous solution through the human skin. As a result, a methodology based on easy, fast, and economical HPLC measurements in a common C18 column has been developed. After a validation based on training and test sets, the method has been applied with good results to the estimation of skin permeation of several hormones and pesticides. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. [Studies of pattern recognition of fingerprint profile of cattle bile powder and determination of multi-component in it].

    PubMed

    Shi, Yan; Zheng, Tian-Jiao; Wei, Feng; Lin, Rui-Chao; Ma, Shuang-Cheng

    2016-07-01

    An HPLC-ELSD method with good specificity and good accuracy was used for the studies of fingerprint and quantification of multi-components for cattle bile powder. The chromatographic analysis was carried out on a Phenomenex Gemini C₁₈ column (4.6 mm×250 mm, 5 μm) with a column temperature of 40 ℃ and a liquid flow-rate of 1.0 mL•min⁻¹ using 10 mmol ammonium acetate solution and acetonitrile as the mobile phase with a linear gradient. An ELSD was used with a nitrogen flow-rate of 2.8 L•h⁻¹, at a drift tube temperature of 110 ℃. The average contents of glycocholic acid, glycodeoxycholic acid, taurocholic acid, taurodeoxycholic acid were (25.2±17.0)%, (4.1±3.4)%, (24.5±20.0)% and (5.2±3.8)% respectively, and the total content of the four bile acids was (59.0±26.0)%. Beyond that, the preprocessing and pattern recognition analysis of the chromatographic fingerprints of samples were applied with chemometric method. The results of this chemometric analysis indicated that the samples from market and self-made samples were different signally, and four regions were noteworthy due to their great impact with poor chromatographic signal. All in one, because this HPLC-ELSD method was simple and accurate, it was suitable for the quality assessment and quality control of cattle bile powder and could be the technological base for its standard perfection. Copyright© by the Chinese Pharmaceutical Association.

  15. Validation of AN Hplc-Dad Method for the Classification of Green Teas

    NASA Astrophysics Data System (ADS)

    Yu, Jingbo; Ye, Nengsheng; Gu, Xuexin; Liu, Ni

    A reversed phase high performance liquid chromatography (RP-HPLC) separation coupled with diode array detection (DAD) and electrospray ionization mass spectrometer (ESI/MS) was developed and optimized for the classification of green teas. Five catechins [epigallocatechin (EGC), epigallocatechin gallate (EGCG), epicatechin (EC), gallocatechin gallate (GCG), epicatechin gallate (ECG)] had been identified and quantified by the HPLC-DAD-ESI/MS/MS method. The limit of detection (LOD) of five catechins was within the range of 1.25-15 ng. All the analytes exhibited good linearity up to 2500 ng. These compounds were considered as chemical descriptors to define groups of green teas. Chemometric methods including principal component analysis (PCA) and hierarchical cluster analysis (HCA) were applied for the purpose. Twelve green tea samples originating from different regions were subjected to reveal the natural groups. The results showed that the analyzed green teas were differentiated mainly by provenance; HCA afforded an excellent performance in terms of recognition and prediction abilities. This method was accurate and reproducible, providing a potential approach for authentication of green teas.

  16. Determination and validation of six sunscreen agents in suncare products by UPLC and HPLC.

    PubMed

    Lee, So-Mi; Jeong, Hye-Jin; Chang, Ih Seop

    2008-01-01

    Methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine are sunscreen agents that have hydrophobic behaviors in common. They were not normally assayed with the following four sunscreen agents that have hydrophilic behaviors in a single chromatographic run: ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. For that reason, methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine require much time in order to assay products with those materials. A rapid, selective, and reproducible determination method needs to be developed for the simultaneous examination of methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine with the sunscreen agents, ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. This new technique could reduce time in examining the sunscreen agents and be effective for quality control of suncare products. In this paper, the HPLC and UPLC system is used for developing the determination of the sunscreen agents. Several evaluations of some mixtures of eluents and columns were obtained for the optimal condition of separation. In HPLC, the optimal peak resolution was obtained through ethanol-water gradient elution and a 75-mm C18 column with a 3.5-microm-sized particle on a flow rate of 1.0 ml/min. In UPLC, the most distinctive peak resolution was obtained through methanol-water gradient elution and a 50-mm C18 column with a 1.7-microm-sized particle on a flow rate 0.4 ml/min. Both of those chromatographic determination methods could be used in the examination of six types of sunscreen agents without any interference from other product excipients in the agents. The proposed determination methods were validated for specificity, linearity, repeatability, system stability, intermediate precision, and accuracy. Consequently, HPLC and UPLC determination methods could be rapid, selective, and proper applications for the assay of sunscreen agents in suncare products.

  17. Resolving and quantifying overlapped chromatographic bands by transmutation

    PubMed

    Malinowski

    2000-09-15

    A new chemometric technique called "transmutation" is developed for the purpose of sharpening overlapped chromatographic bands in order to quantify the components. The "transmutation function" is created from the chromatogram of the pure component of interest, obtained from the same instrument, operating under the same experimental conditions used to record the unresolved chromatogram of the sample mixture. The method is used to quantify mixtures containing toluene, ethylbenzene, m-xylene, naphthalene, and biphenyl from unresolved chromatograms previously reported. The results are compared to those obtained using window factor analysis, rank annihilation factor analysis, and matrix regression analysis. Unlike the latter methods, the transmutation method is not restricted to two-dimensional arrays of data, such as those obtained from HPLC/DAD, but is also applicable to chromatograms obtained from single detector experiments. Limitations of the method are discussed.

  18. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  19. Differentiating organic from conventional peppermints using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were tested for their potential in differentiating organic and conventional peppermint samples. Ten organic and ten conventional peppermint samples were examined using HPLC-UV and FI...

  20. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation.

    PubMed

    Beg, Sarwar; Chaudhary, Vandna; Sharma, Gajanand; Garg, Babita; Panda, Sagar Suman; Singh, Bhupinder

    2016-06-01

    The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm. A Box-Behnken design was applied for chromatographic method optimization taking mobile phase ratio, pH and flow rate as the critical method parameters (CMPs) from screening studies. Peak area, retention time, theoretical plates and peak tailing were measured as the critical analytical attributes (CAAs). Further, the bioanalytical liquid-liquid extraction process was optimized using an optimal design by selecting extraction time, centrifugation speed and temperature as the CMPs for percentage recovery of nevirapine as the CAA. The search for an optimum chromatographic solution was conducted through numerical desirability function. Validation studies performed as per the US Food and Drug Administration requirements revealed results within the acceptance limit. In a nutshell, the studies successfully demonstrate the utility of analytical QbD approach for the rational development of a bioanalytical method with enhanced chromatographic separation and recovery of nevirapine in rat plasma. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Reversed-phase thin-layer chromatography of homologs of Antimycin-A and related derivatives

    USGS Publications Warehouse

    Abidi, Sharon L.

    1989-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  2. Confirmatory analysis of 17beta-boldenone, 17alpha-boldenone and androsta-1,4-diene-3,17-dione in bovine urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Draisci, Rosa; Palleschi, Luca; Ferretti, Emanuele; Lucentini, Luca; delli Quadri, Fernanda

    2003-06-15

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for confirmatory analysis of 17beta-boldenone (17beta-BOL), 17alpha-boldenone (17alpha-BOL) and androsta-1,4-diene-3,17-dione (ADD) in bovine urine was developed. [2H(2)]17beta-Testosterone (17beta-T-d(2)) was used as the internal standard. Sample preparation involved enzymatic hydrolysis and purification on a C(18) solid-phase extraction column. Chromatographic separation of the analytes was obtained using an RP-C(18) HPLC column. LC-MS-MS detection was carried out with an atmospheric pressure chemical ionisation (APCI) source equipped with a heated nebulizer (HN) interface operating in the positive ion mode. For unambiguous hormone confirmation, three analyte precursor-product ion combinations were monitored during multiple-reaction monitoring (MRM) LC-MS-MS analysis. Overall recovery (%), repeatability (relative standard deviations, RSD, %) and within-laboratory reproducibility (RSD, %) ranged from 92.2 to 97.7%, from 6.50 to 2.94% and from 13.50 to 5.04%, respectively, for all analytes. The limit of quantification in bovine urine was 0.20 ng ml(-1) for 17beta-BOL and ADD and 0.50 ng ml(-1) for 17alpha-BOL. The validated method was successfully applied for determination of 17beta-BOL, 17alpha-BOL and ADD in a large number of bovine urine samples collected within the national Official Residue Control Program.

  3. Simultaneous Release and Labeling of O- and N-Glycans Allowing for Rapid Glycomic Analysis by Online LC-UV-ESI-MS/MS.

    PubMed

    Wang, Chengjian; Lu, Yu; Han, Jianli; Jin, Wanjun; Li, Lingmei; Zhang, Ying; Song, Xuezheng; Huang, Linjuan; Wang, Zhongfu

    2018-05-24

    Most glycoproteins and biological protein samples undergo both O- and N-glycosylation, making characterization of their structures very complicated and time-consuming. Nevertheless, to fully understand the biological functions of glycosylation, both the glycosylation forms need to be analyzed. Herein we report a versatile, convenient one-pot method in which O- and N-glycans are simultaneously released from glycoproteins and chromogenically labeled in situ and thus available for further characterization. In this procedure, glycoproteins are incubated with 1-phenyl-3-methyl-5-pyrazolone (PMP) in aqueous ammonium hydroxide, making O-glycans released from protein backbones by β-elimination and N-glycans liberated by alkaline hydrolysis. The released glycans are promptly derivatized with PMP in situ by Knoevenagel condensation and Michael addition, with peeling degradation almost completely prevented. The recovered mixture of O- and N-glycans as bis-PMP derivatives features strong ultraviolet (UV) absorbing ability and hydrophobicity, allowing for high-resolution chromatographic separation and high-sensitivity spectrometric detection. Using this technique, O- and N-glycans were simultaneously prepared from some model glycoproteins and complex biological samples, without significant peeling, desialylation, deacetylation, desulfation or other side-reactions, and then comprehensively analyzed by online HILIC-UV-ESI-MS/MS and RP-HPLC-UV-ESI-MS/MS, with which some novel O- and N-glycan structures were first found. This method provides a simple, versatile strategy for high-throughput glycomics analysis.

  4. Structural elucidation of potential impurities in Azilsartan bulk drug by HPLC.

    PubMed

    Zhou, Wentao; Zhou, Yuxia; Sun, Lili; Zou, Qiaogen; Wei, Ping; Ouyang, Pingkai

    2014-01-01

    During the synthesis of Azilsartan (AZS), it was speculated that 15 potential impurities would arise. This study investigated the possible mechanism for the formation of 14 of them, and their structures were characterized and confirmed by IR, NMR, and MS techniques. In addition, an efficient chromatographic method was developed to separate and quantify these impurities, using an Inertsil ODS-3 column (250 x 4.6 mm, 5 pm) in gradient mode with a mixture of acetonitrile and the potassium dihydrogen orthophosphate buffer (10 mM, pH adjusted to 3.0 with phosphoric acid). The HPLC method was validated for specificity, precision, accuracy, and sensitivity. LOQ of impurities were in the range of 1.04-2.20 ng. Correlation coefficient values of linearity were >0.9996 for AZS and its impurities. The mean recoveries of all impurities in AZS were between 93.0 and 109.7%. Thus, the validated HPLC method is suitable for the separation and quantification of all potential impurities in AZS.

  5. Low molecular weight squash trypsin inhibitors from Sechium edule seeds.

    PubMed

    Laure, Hélen J; Faça, Vítor M; Izumi, Clarice; Padovan, Júlio C; Greene, Lewis J

    2006-02-01

    Nine chromatographic components containing trypsin inhibitor activity were isolated from Sechium edule seeds by acetone fractionation, gel filtration, affinity chromatography and RP-HPLC in an overall yield of 46% of activity and 0.05% of protein. The components obtained with highest yield of total activity and highest specific activity were sequenced by Edman degradation and their molecular masses determined by mass spectrometry. The inhibitors contained 31, 32 and 27 residues per molecule and their sequences were: SETI-IIa, EDRKCPKILMRCKRDSDCLAKCTCQESGYCG; SETI-IIb, EEDRKCPKILMRCKRDSDCLAKCTCQESGYCG and SETI-V, CPRILMKCKLDTDCFPTCTCRPSGFCG. SETI-IIa and SETI-IIb, which differed by an amino-terminal E in the IIb form, were not separable under the conditions employed. The sequences are consistent with consensus sequences obtained from 37 other inhibitors: CPriI1meCk_DSDCla_C_C_G_CG, where capital letters are invariant amino acid residues and lower case letters are the most preserved in this position. SETI-II and SETI-V form complexes with trypsin with a 1:1 stoichiometry and have dissociation constants of 5.4x10(-11)M and 1.1x10(-9)M, respectively.

  6. LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF TRANS-CHLORDANE, CIS-CHLORDANE, HEPTACHLOR, HEPTACHLOR EPOXIDE AND ALPHA-HEXACHLOROCYCLOHEXANE WITH APPLICATION TO SMALL-SCALE PREPARATIVE SEPARATION

    EPA Science Inventory

    Analytical high-performance liquid chromatographic separations of the individual enantiomers of five polychlorinated compounds were obtained on polysaccharide stereoselective HPLC columns. The enantiomers of the pesticides trans-chlordane, cis-chlordane and heptachlor were separa...

  7. High performance liquid chromatography method for the determination of cinnamyl alcohol dehydrogenase activity in soybean roots.

    PubMed

    dos Santos, W D; Ferrarese, Maria de Lourdes Lucio; Ferrarese-Filho, O

    2006-01-01

    This study proposes a simple, quick and reliable method for determining the cinnamyl alcohol dehydrogenase (CAD; EC 1.1.1.195) activity in soybean (Glycine max L. Merr.) roots using reversed-phase high performance liquid chromatography (RP-HPLC). The method includes a single extraction of the tissue and conduction of the enzymatic reaction at 30 degrees C with cinnamaldehydes (coniferyl or sinapyl), substrates of CAD. Disappearance of the substrates in the reaction mixture is monitored at 340 nm (for coniferaldehyde) or 345 nm (for sinapaldehyde) by isocratic elution with methanol/acetic acid through a GLC-ODS (M) column. This HPLC technique furnishes a rapid and reliable measure of cinnamaldehyde substrates, and may be used as an alternative tool to analyze CAD activity in enzyme preparation without previous purification.

  8. Quantitative estimation of itopride hydrochloride and rabeprazole sodium from capsule formulation.

    PubMed

    Pillai, S; Singhvi, I

    2008-09-01

    Two simple, accurate, economical and reproducible UV spectrophotometric methods and one HPLC method for simultaneous estimation of two component drug mixture of itopride hydrochloride and rabeprazole sodium from combined capsule dosage form have been developed. First developed method involves formation and solving of simultaneous equations using 265.2 nm and 290.8 nm as two wavelengths. Second method is based on two wavelength calculation, wavelengths selected for estimation of itopride hydrochloride was 278.0 nm and 298.8 nm and for rabeprazole sodium 253.6 nm and 275.2 nm. Developed HPLC method is a reverse phase chromatographic method using phenomenex C(18) column and acetonitrile: phosphate buffer (35:65 v/v) pH 7.0 as mobile phase. All developed methods obey Beer's law in concentration range employed for respective methods. Results of analysis were validated statistically and by recovery studies.

  9. Quantitative Estimation of Itopride Hydrochloride and Rabeprazole Sodium from Capsule Formulation

    PubMed Central

    Pillai, S.; Singhvi, I.

    2008-01-01

    Two simple, accurate, economical and reproducible UV spectrophotometric methods and one HPLC method for simultaneous estimation of two component drug mixture of itopride hydrochloride and rabeprazole sodium from combined capsule dosage form have been developed. First developed method involves formation and solving of simultaneous equations using 265.2 nm and 290.8 nm as two wavelengths. Second method is based on two wavelength calculation, wavelengths selected for estimation of itopride hydrochloride was 278.0 nm and 298.8 nm and for rabeprazole sodium 253.6 nm and 275.2 nm. Developed HPLC method is a reverse phase chromatographic method using phenomenex C18 column and acetonitrile: phosphate buffer (35:65 v/v) pH 7.0 as mobile phase. All developed methods obey Beer's law in concentration range employed for respective methods. Results of analysis were validated statistically and by recovery studies. PMID:21394269

  10. Development and validation of a stability indicating HPLC method for determination of lisinopril, lisinopril degradation product and parabens in the lisinopril extemporaneous formulation.

    PubMed

    Beasley, Christopher A; Shaw, Jessica; Zhao, Zack; Reed, Robert A

    2005-03-09

    The purpose of the research described herein was to develop and validate a stability-indicating HPLC method for lisinopril, lisinopril degradation product (DKP), methyl paraben and propyl paraben in a lisinopril extemporaneous formulation. The method developed in this report is selective for the components listed above, in the presence of the complex and chromatographically rich matrix presented by the Bicitra and Ora-Sweet SF formulation diluents. The method was also shown to have adequate sensitivity with a detection limit of 0.0075 microg/mL (0.03% of lisinopril method concentration). The validation elements investigated showed that the method has acceptable specificity, recovery, linearity, solution stability, and method precision. Acceptable robustness indicates that the assay method remains unaffected by small but deliberate variations, which are described in ICH Q2A and Q2B guidelines.

  11. Ionic liquids improved reversed-phase HPLC on-line coupled with ICP-MS for selenium speciation.

    PubMed

    Chen, Beibei; He, Man; Mao, Xiangju; Cui, Ran; Pang, Daiwen; Hu, Bin

    2011-01-15

    Room-temperature ionic liquids (RTILs) improved reversed-phase high performance liquid chromatography (RP-HPLC) on-line combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for selenium speciation. The different parameters affecting the retention behaviors of six target selenium species especially the effect of RTILs as mobile phase additives have been studied, it was found that the mobile phase consisting of 0.4% (v/v) 1-butyl-3-methylimidazolium chloride ([BMIM]Cl), 0.4% (v/v) 1-butyl-2,3-dimethylimidazolium tetrafluroborate ([BMMIM]BF(4)) and 99.2% (v/v) water has effectively improved the peak profile and six target selenium species including Na(2)SeO(3) (Se(IV)), Na(2)SeO(4) (Se(VI)), L-selenocystine (SeCys(2)), D,L-selenomethionine (SeMet), Se-methylseleno-l-cysteine (MeSeCys), seleno-D,L-ethionine (SeEt) were separated in 8 min. In order to validate the accuracy of the method, a Certified Reference Material of SELM-1 yeast sample was analyzed and the results obtained were in good agreement with the certified values. The developed method was also successfully applied to the speciation of selenium in Se-enriched yeasts and clover. For fresh Se-enriched yeast cells, it was found that the spiked SeCys(2) in living yeast cells could be transformed into SeMet. Compared with other ion-pair RP-HPLC-ICP-MS approaches for selenium speciation, the proposed method possessed the advantages including ability to regulate the retention time of the target selenium species by selecting the suitable RTILs and their concentration, simplicity, rapidness and low injection volume, thus providing wide potential applications for elemental speciation in biological systems. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Report: An ex vivo up-take of levamisole molecules by cestode (Monezia expensa) of goat (Capra hirsa) and its detection through RP-HPLC.

    PubMed

    Ayaz, Muhammad Mazhar; Sajid, Muhammad; Das, Sanjota Nirmal; Hanif, Muhammad

    2018-05-01

    Detection of various molecules of drugs remained a prime issue especially in tissues of animals, humans and in their target parasites. The cestode/tapeworms pose a dilemma because of their weird body composition and uptake pattern of nutrients and medicines especially through absorption by tegument. We selected levamisole; thought to be potent antiparasitic/ani-cestodal drug. The uptake of levamisole (LEV) through cestodeal tissues is studied through HPCL in this paper. High performance liquid chromatography technique has been utilized to know the uptake of levamisole in tissues of cestodes of Goat (Monezia expensa) in small ruminants. The drug was exposed to M. expensa by in vitro till its death or a parasite ceases its movement. The tissue/ part of proglattids of the M. expensa were homogenized with some modifications and levamisole extraction was performed with liquid phase extraction method. The evaporation of solvent was done and the residual cestodal tissues were cleaned by solid phase. After the solid phase extraction method, the recovery of drug, detection and quantification of levamisole from cestodal tissues was determined through Reverse Phase Column High Performance Liquid Chromatography (RP-HPLC). Levamisole (LEV) molecules assay was obtained on a C18 reverse-phase (20um, 6mm x 150mm) column at flow rate of 1ml/min using acetonitrile and ammonium acetate as mobile phase and UV detection was done at 254nm. The development of method of Levamisole (LEV) detection from cestodal tissues by HPLC in vitro samples has been demonstrated first time in Pakistan, which can provide the solution of parasitic control and provide in sight in to the uptake of anti cestodal drugs either against human or livestock parasites.

  13. HPTLC method for the simultaneous determination of four indole alkaloids in Rauwolfia tetraphylla: a study of organic/green solvent and continuous/pulse sonication.

    PubMed

    Gupta, Shikha; Shanker, Karuna; Srivastava, Santosh K

    2012-07-01

    A new validated high-performance thin-layer chromatographic (HPTLC) method has been developed for the simultaneous quantitation of four antipsychotic indole alkaloids (IAs), reserpiline (RP, 1), α-yohimbine (YH, 2), isoreserpiline (IRP, 3) and 10-methoxy tetrahydroalstonine (MTHA, 4) as markers in the leaves of Rauwolfia tetraphylla. Extraction efficiency of the targeted IAs from the leaf matrix with organic and ecofriendly (green) solvents using percolation, ultrasonication and microwave techniques were studied. Non-ionic surfactants, viz. Triton X-100, Triton X-114 and Genapol X-80 were used for extraction and no back-extraction or liquid chromatographic steps were used to remove the targeted IAs from the surfactant-rich extractant phase. The optimized cloud point extraction was found a potentially useful methodology for the preconcentration of the targeted IAs. The separation was achieved on silica gel 60F(254) HPTLC plates using hexane-ethylacetate-methanol (5:4:1, v/v/v) as mobile phase. The quantitation of IAs (1-4) was carried out using the densitometric reflection/absorption mode at 520 nm after post chromatographic derivatization using Dragendorff's reagent. The method was validated for peak purity, precision, accuracy, robustness, limit of detection (LOD) and quantitation (LOQ). Method specificity was confirmed using retention factor (R(f)) and visible spectral (post chromatographic scan) correlation of marker compounds in the samples and standard tracks. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Validation of a fast and accurate chromatographic method for detailed quantification of vitamin E in green leafy vegetables.

    PubMed

    Cruz, Rebeca; Casal, Susana

    2013-11-15

    Vitamin E analysis in green vegetables is performed by an array of different methods, making it difficult to compare published data or choosing the adequate one for a particular sample. Aiming to achieve a consistent method with wide applicability, the current study reports the development and validation of a fast micro-method for quantification of vitamin E in green leafy vegetables. The methodology uses solid-liquid extraction based on the Folch method, with tocol as internal standard, and normal-phase HPLC with fluorescence detection. A large linear working range was confirmed, being highly reproducible, with inter-day precisions below 5% (RSD). Method sensitivity was established (below 0.02 μg/g fresh weight), and accuracy was assessed by recovery tests (>96%). The method was tested in different green leafy vegetables, evidencing diverse tocochromanol profiles, with variable ratios and amounts of α- and γ-tocopherol, and other minor compounds. The methodology is adequate for routine analyses, with a reduced chromatographic run (<7 min) and organic solvent consumption, and requires only standard chromatographic equipment available in most laboratories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Comparison of high-performance liquid chromatography and supercritical fluid chromatography using evaporative light scattering detection for the determination of plasticizers in medical devices.

    PubMed

    Lecoeur, Marie; Decaudin, Bertrand; Guillotin, Yoann; Sautou, Valérie; Vaccher, Claude

    2015-10-23

    Recently, interest in supercritical fluid chromatography (SFC) has increased due to its high throughput and the development of new system improving chromatographic performances. However, most papers dealt with fundamental studies and chiral applications and only few works described validation process of SFC method. Likewise, evaporative light scattering detection (ELSD) has been widely employed in liquid chromatography but only a few recent works presented its quantitative performances hyphenated with SFC apparatus. The present paper discusses about the quantitative performances of SFC-ELSD compared to HPLC-ELSD, for the determination of plasticizers (ATBC, DEHA, DEHT and TOTM) in PVC tubing used as medical devices. After the development of HPLC-ELSD, both methods were evaluated based on the total error approach using accuracy profile. The results show that HPLC-ELSD was more precise than SFC-ELSD but lower limits of quantitation were obtained by SFC. Hence, HPLC was validated in the ± 10% acceptance limits whereas SFC lacks of accuracy to quantify plasticizers. Finally, both methods were used to determine the composition of plasticized-PVC medical devices. Results demonstrated that SFC and HPLC both hyphenated with ELSD provided similar results. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. HPLC detection of soluble carbohydrates involved in mannitol and trehalose metabolism in the edible mushroom Agaricus bisporus.

    PubMed

    Wannet, W J; Hermans, J H; van Der Drift, C; Op Den Camp, H J

    2000-02-01

    A convenient and sensitive method was developed to separate and detect various types of carbohydrates (polyols, mono- and disaccharides, and phosphorylated sugars) simultaneously using high-performance liquid chromatography (HPLC). The method consists of a chromatographic separation on a CarboPac PA1 anion-exchange analytical column followed by pulsed amperometric detection. In a single run (43 min) 13 carbohydrates were readily resolved. Calibration plots were linear over the ranges of 5-25 microM to 1. 0-1.5 mM. The reliable and fast analysis technique, avoiding derivatization steps and long run times, was used to determine the levels of carbohydrates involved in mannitol and trehalose metabolism in the edible mushroom Agaricus bisporus. Moreover, the method was used to study the trehalose phosphorylase reaction.

  17. Fingerprint chromatogram analysis of Pseudostellaria heterophylla (Miq.) Pax root by high performance liquid chromatography.

    PubMed

    Han, Chao; Chen, Junhui; Chen, Bo; Lee, Frank Sen-Chun; Wang, Xiaoru

    2006-09-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the fingerprinting of extracts from the root of Pseudostellaria heterophylla (Miq.) Pax. HPLC with gradient elution was performed on an authentic reference standard of powdered P. heterophylla (Miq.) Pax root and 11 plant samples of the root were collected from different geographic locations. The HPLC chromatograms have been standardized through the selection and identification of reference peaks and the normalization of retention times and peak intensities of all the common peaks. The standardized HPLC fingerprints show high stability and reproducibility, and thus can be used effectively for the screening analysis or quality assessment of the root or its derived products. Similarity index calculations based on cosine angle values or correlation methods have been performed on the HPLC fingerprints. As a group, the fingerprints of the P. heterophylla (Miq.) Pax samples studied are highly correlated with closely similar fingerprints. Within the group, the samples can be further divided into subgroups based on hierarchical clustering analysis (HCA). Sample grouping based on HCA coincides nicely with those based on the geographical origins of the samples. The HPLC fingerprinting techniques thus have high potential in authentication or source-tracing types of applications.

  18. A method for the measurement of atmospheric HONO based on DNPH derivatization and HPLC analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, X.; Qiao, H.; Deng, G.

    1999-10-15

    A simple measurement technique was developed for atmospheric HONO based on aqueous scrubbing using a coil sampler followed by 2,4-dinitrophenylhydrazine (DNPH) derivatization and high-performance liquid chromatographic (HPLC) analysis. Quantitative sampling efficiency was obtained using a 1 mM phosphate buffer, pH 7.0, as the scrubbing solution at a gas sampling flow rate of 2 L min{sup {minus}1} and a liquid flow rate of 0.24 mL min{sup {minus}1}. Derivation of the scrubbed nitrous acid by DNPH was fast and was completed within 5 min in a derivatization medium containing 300 {micro}M DNPH and 8 mM HCI at 45 C. The azide derivativemore » was separated from DNPH reagent and carbonyl derivatives by reverse-phase HPLC and was detected with an UV detector at 309 nm. The detection limit is {le}5 pptv and may be lowered to 1 pptv with further DNPH purification. Interferences from NO, NO{sub 2} PAN, O{sub 3}, HNO{sub 3}, and HCHO were studied and found to be negligible. Ambient HONO concentration was measured simultaneously in downtown Albany, NY, by this method and by an ion chromatographic technique after sampling using a fritted bubbler. The results, from 70 pptv during the day to 1.7 ppbv in the early morning, were in very good agreement from the two techniques, within {+-} 20%.« less

  19. [Research on the application of grey system theory in the pattern recognition for chromatographic fingerprints of traditional Chinese medicine].

    PubMed

    Wei, Hang; Lin, Li; Zhang, Yuan; Wang, Lianjing; Chen, Qinqun

    2013-02-01

    A model based on grey system theory was proposed for pattern recognition in chromatographic fingerprints (CF) of traditional Chinese medicine (TCM). The grey relational grade among the data series of each testing CF and the ideal CF was obtained by entropy and norm respectively, then the principle of "maximal matching degree" was introduced to make judgments, so as to achieve the purpose of variety identification and quality evaluation. A satisfactory result in the high performance liquid chromatographic (HPLC) analysis of 56 batches of different varieties of Exocarpium Citrus Grandis was achieved with this model. The errors in the chromatographic fingerprint analysis caused by traditional similarity method or grey correlation method were overcome, as the samples of Citrus grandis 'Tomentosa' and Citrus grandis (L.) Osbeck were correctly distinguished in the experiment. Furthermore in the study on the variety identification of Citrus grandis 'Tomentosa', the recognition rates were up to 92.85%, although the types and the contents of the chemical compositions of the samples were very close. At the same time, the model had the merits of low computation complexity and easy operation by computer programming. The research indicated that the grey system theory has good applicability to pattern recognition in the chromatographic fingerprints of TCM.

  20. HPLC column-switching technique for sample preparation and fluorescence determination of propranolol in urine using fused-core columns in both dimensions.

    PubMed

    Satínský, Dalibor; Havlíková, Lucie; Solich, Petr

    2013-08-01

    A new and fast high-performance liquid chromatography (HPLC) column-switching method using fused-core columns in both dimensions for sample preconcentration and determination of propranolol in human urine has been developed. On-line sample pretreatment and propranolol preconcentration were performed on an Ascentis Express RP-C-18 guard column (5 × 4.6 mm), particle size, 2.7 μm, with mobile phase acetonitrile/water (5:95, v/v) at a flow rate of 2.0 mL min(-1) and at a temperature of 50 °C. Valve switch from pretreatment column to analytical column was set at 4.0 min in a back-flush mode. Separation of propranolol from other endogenous urine compounds was achieved on the fused-core column Ascentis Express RP-Amide (100 × 4.6 mm), particle size, 2.7 μm, with mobile phase acetonitrile/water solution of 0.5% triethylamine, pH adjusted to 4.5 by means of glacial acetic acid (25:75, v/v), at a flow rate of 1.0 mL min(-1) and at a temperature of 50 °C. Fluorescence excitation/emission detection wavelengths were set at 229/338 nm. A volume of 1,500 μL of filtered urine sample solution was injected directly into the column-switching HPLC system. The total analysis time including on-line sample pretreatment was less than 8 min. The experimentally determined limit of detection of the method was found to be 0.015 ng mL(-1).

  1. Identification of Potent ACE Inhibitory Peptides from Wild Almond Proteins.

    PubMed

    Mirzapour, Mozhgan; Rezaei, Karamatollah; Sentandreu, Miguel Angel

    2017-10-01

    In this study, the production, fractionation, purification and identification of ACE (angiotensin-I-converting enzyme) inhibitory peptides from wild almond (Amygdalus scoparia) proteins were investigated. Wild almond proteins were hydrolyzed using 5 different enzymes (pepsin, trypsin, chymotrypsin, alcalase and flavourzyme) and assayed for their ACE inhibitory activities. The degree of ACE inhibiting activity obtained after hydrolysis was found to be in the following order: alcalase > chymotrypsin > trypsin/pepsin > flavourzyme. The hydrolysates obtained from alcalase (IC 50 = 0.8 mg/mL) were fractionated by sequential ultrafiltration at 10 and 3 kDa cutoff values and the most active fraction (<3 kDa) was further separated using reversed phase high-performance liquid chromatography (RP-HPLC). Peptide sequence identifications were carried out on highly potential fractions obtained from RP-HPLC by means of liquid chromatography coupled to electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS). Sequencing of ACE inhibitory peptides present in the fraction 26 of RP-HPLC resulted in the identification of 3 peptide sequences (VVNE, VVTR, and VVGVD) not reported previously in the literature. Sequence identification of fractions 40 and 42 from RP-HPLC, which showed the highest ACE inhibitory activities (84.1% and 86.9%, respectively), resulted in the identification of more than 40 potential ACE inhibitory sequences. The results indicate that wild almond protein is a rich source of potential antihypertensive peptides and can be suggested for applications in functional foods and drinks with respect to hindrance and mitigation of hypertension after in vivo assessment. This study has shown the potential of wild almond proteins as good sources for producing ACE-inhibitory active peptides. According to this finding, peptides with higher ACE inhibitory activities could be released during the gastrointestinal digestion and contribute to the health- promoting activities of this natural protein source. © 2017 Institute of Food Technologists®.

  2. Investigating biological activity spectrum for novel quinoline analogues 2: hydroxyquinolinecarboxamides with photosynthesis-inhibiting activity.

    PubMed

    Musiol, Robert; Tabak, Dominik; Niedbala, Halina; Podeszwa, Barbara; Jampilek, Josef; Kralova, Katarina; Dohnal, Jiri; Finster, Jacek; Mencel, Agnieszka; Polanski, Jaroslaw

    2008-04-15

    Two series of amides based on quinoline scaffold were designed and synthesized in search of photosynthesis inhibitors. The compounds were tested for their photosynthesis-inhibiting activity against Spinacia oleracea L. and Chlorella vulgaris Beij. The compounds lipophilicity was determined by the RP-HPLC method. Several compounds showed biological activity similar or even higher than that of the standard (DCMU). The structure-activity relationships are discussed.

  3. Reversed-phase HPLC analysis of levetiracetam in tablets using monolithic and conventional C18 silica columns.

    PubMed

    Can, Nafiz O; Arli, Goksel

    2010-01-01

    Development and validation of an RP-HPLC method for determination of levetiracetam in pharmaceutical tablets is described. The separation and quantification of levetiracetam and caffeine (internal standard) were performed using a single analytical procedure with two different types of stationary phases, conventional Phenomenex Gemini C18 (100 x 4.6 mm, 5 microm) and Merck Chromolith Performance RP18e (100 x 4.6 mm, macropore size 2 mm, micropore size 13 nm) monolithic silica. Five-microliter aliquots of samples were injected into the system and eluted using water-acetonitrile (90 + 10, v/v) mobile phase pumped at the rate of 1 mL/min. The analyte peaks were detected at 200 nm using a diode array detector with adequate resolution. Validation studies were performed using the method recommended by the International Conference on Harmonization, the U.S. Pharmacopeia, and AOAC INTERNATIONAL, which includes accuracy, precision, range, limits, robustness, and system suitability parameters. Levetiracetam and caffeine were detected in about 7 min using the conventional column, whereas less than 5 min was required when the monolithic column was used. Calibration plots had r values close to unity in the range of 0.8-8.0 microg/mL. Assay of levetiracetam in a tablet formulation was demonstrated as an application to real samples.

  4. Simple and sensitive determination of five quinolones in food by liquid chromatography with fluorescence detection.

    PubMed

    Ramos, Macarena; Aranda, Angela; Garcia, Elena; Reuvers, Thea; Hooghuis, Henny

    2003-06-15

    A simple and sensitive high-performance liquid chromatographic (HPLC) method has been developed for the determination of five different quinolones: enrofloxacin, ciprofloxacin, sarafloxacin, oxolinic acid and flumequine in pork and salmon muscle. The method includes one extraction and clean-up step for the five quinolones together which are detected in two separated HPLC runs by means of their fluorescence. The proposed analytical method involves homogenizing of the tissue sample with 0.05 M phosphate buffer, pH 7.4 and clean-up by Discovery DS-18 cartridges. For chromatographic separation a Symmetry C(18) column is used in two different runs: (1) ciprofloxacin, enrofloxacin and sarafloxacin with acetonitrile-0.02 M phosphate buffer pH 3.0 (18:82) as mobile phase and the detector at excitation wavelength: 280 nm and emission wavelength 450 nm; and (2) oxolinic acid and flumequine with acetonitrile-0.02 M phosphate buffer pH 3.0 (34:66) as mobile phase and excitation wavelength: 312 nm and emission wavelength: 366 nm. Detection limit was as low as 5 ng g(-1), except for sarafloxacin which had a limit of 10 ng g(-1). Standard curves using blank muscle tissues spiked at different levels showed a good linear correlation coefficient, r(2) higher than 0.999 for all quinolones.

  5. Industrial application of green chromatography--I. Separation and analysis of niacinamide in skincare creams using pure water as the mobile phase.

    PubMed

    Yang, Yu; Strickland, Zackary; Kapalavavi, Brahmam; Marple, Ronita; Gamsky, Chris

    2011-03-15

    In this work, chromatographic separation of niacin and niacinamide using pure water as the sole component in the mobile phase has been investigated. The separation and analysis of niacinamide have been optimized using three columns at different temperatures and various flow rates. Our results clearly demonstrate that separation and analysis of niacinamide from skincare products can be achieved using pure water as the eluent at 60°C on a Waters XTerra MS C18 column, a Waters XBridge C18 column, or at 80°C on a Hamilton PRP-1 column. The separation efficiency, quantification quality, and analysis time of this new method are at least comparable with those of the traditional HPLC methods. Compared with traditional HPLC, the major advantage of this newly developed green chromatography technique is the elimination of organic solvents required in the HPLC mobile phase. In addition, the pure water chromatography separations described in this work can be directly applied in industrial plant settings without further modification of the existing HPLC equipment. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. A Simple and Rapid HPLC-PDA MS Method for the Profiling of Citrus Peels and Traditional Italian Liquors.

    PubMed

    Guccione, Clizia; Bergonzi, Maria Camilla; Piazzini, Vieri; Bilia, Anna Rita

    2016-07-01

    A chromatographic method for the qualitative and quantitative characterization of peels and preparations based on different species of Citrus was developed in order to obtain a complete profile of the constituents, including flavonoids and protoalkaloids. Commercial peels of sweet orange, lemon, mandarin, and grapefruit were analyzed. Seventeen constituents including flavanones, flavones, polymethoxyflavones, and protoalkaloids were identified by HPLC-PDA, HPLC-MS, and HPLC-MS/MS using a comparison of retention times and UV-Vis and MS spectra with reference standards and literature data. The total amount of flavanones [neoeriocitrin (5), naringin (8) and hesperidin (9)] and polymethoxflavones [sinensetin (12), nobiletin (14), 3,5,6,7,8,3',4'-heptamethoxyflavone (15), and tangeretin (16)] was determined and expressed as naringin (8) or hesperidin (9), and sinensetin (12), respectively. The protoalkaloid synephrine was detected in all samples, except in grapefruit, but its content was lower than the limit of quantification. Qualitative and quantitative chemical profiles of three different Italian aromatic liquors ("Limoncello", "Arancello", and "Mandarinetto"), prepared according to traditional recipes, were also analyzed. Georg Thieme Verlag KG Stuttgart · New York.

  7. New Stability-Indicating RP-HPLC Method for Determination of Diclofenac Potassium and Metaxalone from their Combined Dosage Form

    PubMed Central

    Panda, Sagar Suman; Patanaik, Debasis; Ravi Kumar, Bera V. V.

    2012-01-01

    A simple, precise and accurate isocratic RP-HPLC stability-indicating assay method has been developed to determine diclofenac potassium and metaxalone in their combined dosage forms. Isocratic separation was achieved on a Hibar-C18, Lichrosphere-100® (250 mm × 4.6 mm i.d., particle size 5 μm) column at room temperature in isocratic mode, the mobile phase consists of methanol: water (80:20, v/v) at a flow rate of 1.0 ml/min, the injection volume was 20 μl and UV detection was carried out at 280nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The method was linear in the drug concentration range of 2.5–30 μg/ml and 20–240 μg/ml for diclofenac potassium and metaxalone, respectively. The precision (RSD) of six samples was 0.83 and 0.93% for repeatability, and the intermediate precision (RSD) among six-sample preparation was 1.63 and 0.49% for diclofenac potassium and metaxalone, respectively. The mean recoveries were between 100.99–102.58% and 99.97–100.01% for diclofenac potassium and metaxalone, respectively. The proposed method can be used successfully for routine analysis of the drug in bulk and combined pharmaceutical dosage forms. PMID:22396909

  8. Use of biopartitioning micellar chromatography and RP-HPLC for the determination of blood-brain barrier penetration of α-adrenergic/imidazoline receptor ligands, and QSPR analysis.

    PubMed

    Vucicevic, J; Popovic, M; Nikolic, K; Filipic, S; Obradovic, D; Agbaba, D

    2017-03-01

    For this study, 31 compounds, including 16 imidazoline/α-adrenergic receptor (IRs/α-ARs) ligands and 15 central nervous system (CNS) drugs, were characterized in terms of the retention factors (k) obtained using biopartitioning micellar and classical reversed phase chromatography (log k BMC and log k wRP , respectively). Based on the retention factor (log k wRP ) and slope of the linear curve (S) the isocratic parameter (φ 0 ) was calculated. Obtained retention factors were correlated with experimental log BB values for the group of examined compounds. High correlations were obtained between logarithm of biopartitioning micellar chromatography (BMC) retention factor and effective permeability (r(log k BMC /log BB): 0.77), while for RP-HPLC system the correlations were lower (r(log k wRP /log BB): 0.58; r(S/log BB): -0.50; r(φ 0 /P e ): 0.61). Based on the log k BMC retention data and calculated molecular parameters of the examined compounds, quantitative structure-permeability relationship (QSPR) models were developed using partial least squares, stepwise multiple linear regression, support vector machine and artificial neural network methodologies. A high degree of structural diversity of the analysed IRs/α-ARs ligands and CNS drugs provides wide applicability domain of the QSPR models for estimation of blood-brain barrier penetration of the related compounds.

  9. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    NASA Technical Reports Server (NTRS)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  10. Development and validation of a new HPLC-UV method for the simultaneous determination of triclabendazole and ivermectin B1a in a pharmaceutical formulation.

    PubMed

    Shurbaji, Maher; Abu Al Rub, Mohamad H; Saket, Munib M; Qaisi, Ali M; Salim, Maher L; Abu-Nameh, Eyad S M

    2010-01-01

    A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.

  11. Steviol quantification at the picomole level by high-performance liquid chromatography.

    PubMed

    Minne, Veerle J Y; Compernolle, Frans; Toppet, Suzanne; Geuns, Jan M C

    2004-05-05

    A simple and highly sensitive reversed-phase high-performance liquid chromatographic method (RP-HPLC) has been developed for the determination of steviol (SV) using dihydroisosteviol (DHISV) as an internal standard (IS). SV and DHISV were derivatized by reaction of the acids with 4-(bromomethyl)-7-methoxycoumarin in an aprotic solvent (DMF or acetone). The resulting ester derivatives were separated on an ODS column (250 x 4.6 mm i.d., 5 microm particle size) using fluorescence detection with excitation at 321 nm and emission at 391 nm. The mobile phase consisted of acetonitrile/water (80:20 v/v) with a flow rate of 1 mL min(-)(1). A linear relationship was observed for concentrations between 0.5 and 50 microg/mL of SV, and the detection limit was 100 pg. For application of this method to samples of beer fortified with stevioside, a simple procedure for extraction of the beer with diethyl ether and derivatization in DMF was applied. Whereas beer samples spiked with SV gave a linear response over the range 0.1-15 microg/mL beer, no SV could be detected in beer samples enriched in stevioside that had been stored for over 3 years. The application of the method to plant samples involved preparation of an acid fraction containing the SV analyte, derivatization, and sample cleanup using small silica columns and thin-layer chromatography. A sensitive determination of 594 ng of steviol present in 100 mg of dry plant material was performed with high precision and accuracy.

  12. A RP-HPLC-DAD-APCI/MSD method for the characterisation of medicinal Ericaceae used by the Eeyou Istchee Cree First Nations.

    PubMed

    Saleem, Ammar; Harris, Cory S; Asim, Muhammad; Cuerrier, Alain; Martineau, Louis; Haddad, Pierre S; Arnason, John T

    2010-01-01

    Ericaceae medicinal plants are traditionally used by the Eeyou Istchee Cree and other northern peoples of North America to treat type 2 diabetic symptoms. Because of the importance of phenolics as potential cures for degenerative diseases including type 2 diabetes, an analytical method was developed to detect them in the leaf extracts of 14 Ericaceae plants. To develop an optimised method which is applicable to a relatively large number of Ericaceae plants using their leaf extracts. For this purpose phenolics with a wide range of polarity, including a glucosylated benzoquinone, two phenolic acids, three flavanols, a flavanone, a flavone and five flavonols, were included in this study. Characterisation of phytochemicals in extracts was undertaken by automated matching to the UV spectra to those of an in house library of plant secondary metabolites and the authentication of their identity was achieved by reversed phase-high-performance chromatography-diode array detection-atmospheric pressure chemical ionisation/mass selective detection. Twenty-six phenolics were characterised within 26 min of chromatographic separation in 80% ethanol extracts of 14 Ericaceae plants. The calibration curves were linear within 0.5-880 microg/g dry mass of the plant with regression values better than 0.995. The limits of detection ranged from 0.3 for microg/mL for (+)-catechin to 2.6 microg/mL for chlorogenic acid. This is a first study dealing with relatively large number of Ericaceae extracts and is applicable to other plants of same family.

  13. Quantitative analysis of matrine in liquid crystalline nanoparticles by HPLC.

    PubMed

    Peng, Xinsheng; Li, Baohong; Hu, Min; Ling, Yahao; Tian, Yuan; Zhou, Yanxing; Zhou, Yanfang

    2014-01-01

    A reversed-phase high-performance liquid chromatographic method has been developed to quantitatively determine matrine in liquid crystal nanoparticles. The chromatographic method is carried out using an isocratic system. The mobile phase was composed of methanol-PBS(pH6.8)-triethylamine (50 : 50 : 0.1%) with a flow rate of 1 mL/min with SPD-20A UV/vis detector and the detection wavelength was at 220 nm. The linearity of matrine is in the range of 1.6 to 200.0  μ g/mL. The regression equation is y = 10706x - 2959 (R (2) = 1.0). The average recovery is 101.7%; RSD = 2.22%  (n = 9). This method provides a simple and accurate strategy to determine matrine in liquid crystalline nanoparticle.

  14. [Study on HPLC fingerprint of flavonoids from Houttuynia cordata by comparing with fingerprint reference].

    PubMed

    Zhang, Ting-Ting; Wu, Yi; Hang, Tai-Jun

    2009-05-01

    To establish a stable and repeatable HPLC fingerprint standard and evaluate the flavonoids from Houttuynia cordata qualitatively and quantitatively. HPLC separation was performed on a C18 column with methanol-0.1% phosphoric acid mixed solution as mobile phase in gradient elution mode. The fingerprint reference was determined as one of the most typical chromatograms and used to be compared with other samples through Cosine and Relative Euclid Distance methods, thus the chromatographic fingerprints of flavonoids from Houttuynia cordata were evaluated by constitutes and contents, respectively. Fourteen mutual peaks were fixed in the HPLC fingerprint of flavonoids from Houttaynia cordata. It showed good results in validation tests in which the quercitrin's peak was set as the reference peak to calculate relative retention time and area of other peaks in the chromatograms, and the RSD were less than 0.2% and 5.0%, respectively. The linear ranges for quercitrin was 1.07-83.4 microg/mL (r=0.9999) and the average recovery was 100.3%. The method shows good repeatability, ruggedness and reliability. Comparing with the established reference fingerprint, the evaluation system including Cosine and Relative Euclid Distance methods lays dependable foundation for controlling the quality of Houttuynia cordata.

  15. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    PubMed

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  16. An optimized high-performance liquid chromatography (HPLC) method for benzoylmesaconine determination in Radix Aconiti Lateralis Preparata (Fuzi, aconite roots) and its products

    PubMed Central

    Xie, Ying; Zhou, Hua; Wong, Yuen Fan; Liu, Zhongqiu; Xu, Hongxi; Jiang, Zhihong; Liu, Liang

    2008-01-01

    Background Benzoylmesaconine (BMA) is the main Aconitum alkaloid in Radix Aconiti Lateralis Preparata (Fuzi, aconite roots) with potent pharmacological activities, such as analgesia and anti-inflammation. The present study developed a simple and reliable method using BMA as a marker compound for the quality control of processed aconite roots and their products. Methods After extraction, a high-performance liquid chromatography (HPLC) determination of BMA was conducted on a RP-C18 column by gradient elution with acetonitrile and aqueous phase, containing 0.1% phosphoric acid adjusted with triethylamine to pH 3.0. Results A distinct peak profile was obtained and separation of BMA was achieved. Method validation showed that the relative standard deviations (RSDs) of the precision of BMA in all intra-day and inter-day assays were less than 1.36%, and that the average recovery rate was 96.95%. Quantitative analysis of BMA showed that the content of BMA varied significantly in processed aconite roots and their products. Conclusion This HPLC method using BMA as a marker compound is applicable to the quality control of processed aconite roots and their products. PMID:18513409

  17. A rapid method for the simultaneous quantification of the major tocopherols, carotenoids, free and esterified sterols in canola (Brassica napus) oil using normal phase liquid chromatography.

    PubMed

    Flakelar, Clare L; Prenzler, Paul D; Luckett, David J; Howitt, Julia A; Doran, Gregory

    2017-01-01

    A normal phase high performance liquid chromatography (HPLC) method was developed to simultaneously quantify several prominent bioactive compounds in canola oil vis. α-tocopherol, γ-tocopherol, δ-tocopherol, β-carotene, lutein, β-sitosterol, campesterol and brassicasterol. The use of sequential diode array detection (DAD) and tandem mass spectrometry (MS/MS) allowed direct injection of oils, diluted in hexane without derivatisation or saponification, greatly reducing sample preparation time, and permitting the quantification of both free sterols and intact sterol esters. Further advantages over existing methods included increased analytical selectivity, and a chromatographic run time substantially less than other reported normal phase methods. The HPLC-DAD-MS/MS method was applied to freshly extracted canola oil samples as well as commercially available canola, palm fruit, sunflower and olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A simple, rapid and sensitive RP-HPLC-UV method for the simultaneous determination of sorafenib & paclitaxel in plasma and pharmaceutical dosage forms: Application to pharmacokinetic study.

    PubMed

    Khan, Ismail; Iqbal, Zafar; Khan, Abad; Hassan, Muhammad; Nasir, Fazle; Raza, Abida; Ahmad, Lateef; Khan, Amjad; Akhlaq Mughal, Muhammad

    2016-10-15

    A simple, economical, fast, and sensitive RP-HPLC-UV method has been developed for the simultaneous quantification of Sorafenib and paclitaxel in biological samples and formulations using piroxicam as an internal standard. The experimental conditions were optimized and method was validated according to the standard guidelines. The separation of both the analytes and internal standard was achieved on Discovery HS C18 column (250mm×4.6mm, 5μm) using Acetonitrile and TFA (0.025%) in the ratio of (65:35V/V) as the mobile phase in isocratic mode at a flow rate of 1ml/min, with a wavelength of 245nm and at a column oven temperature of 25°Cin a short run time of 12min. The limits of detection (LLOD) were 5 and 10ng/ml while the limits of quantification (LLOQ) were 10 and 15ng/ml for sorafenib and paclitaxel, respectively. Sorafenib, paclitaxel and piroxicam (IS) were extracted from biological samples by applying acetonitrile as a precipitating and extraction solvent. The method is linear in the range of 15-20,000ng/ml for paclitaxel and 10-5000ng/ml for sorafenib, respectively. The method is sensitive and reliable by considering both of its intra-day and inter-day co-efficient of variance. The method was successfully applied for the quantification of the above mentioned drugs in plasma. The developed method will be applied towards sorafenib and paclitaxel pharmacokinetics studies in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. [Chemical constituents of the roots of Vaccinium bracteatum].

    PubMed

    Lv, Xiao-Lan; Mai, Xi; Guo, Hui; Lai, Xiao-Ping

    2012-06-01

    To study the chemical constituents of the roots of Vaccinium bracteatum. The constituents were separated and purified with chromatographic methods (including silica gel, Sephadex LH-20 and RP-18 column chromatography), and their structures were determined by spectroscopic methods (including MS, 1H-NMR and 13C-NMR). 10 compounds were isolated from the roots of Vaccinium bracteatu and were elucidated as chlorogenic acid (1), pinoresinol (2), ferulic acid (3), kaempferol (4), trans-caffeic acid (5), beta-sitosterol (6), quercetin (7), oleanolic acid (8), apigenin (9) and luteolin (10). Compounds 1 -3 are obtained from this plant for the first time.

  20. Gradient Scouting in Reversed-Phase HPLC Revisited

    ERIC Educational Resources Information Center

    Alcazar, A.; Jurado, J. M.; Gonzalez, A. G.

    2011-01-01

    Gradient scouting is the best way to decide the most suitable elution mode in reversed-phase high-performance liquid chromatography (RP-HPLC). A simple rule for this decision involves the evaluation of the ratio [delta]t/t[subscript G] (where [delta]t is the difference in the retention time between the last and the first peak and t[subscript G] is…