Sample records for chromatographic separation process

  1. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, Frederick T.

    1981-01-01

    Intermetallic compounds with the CaCu.sub.5 type of crystal structure, particularly LaNiCo.sub.4 and CaNi.sub.5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  2. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, F.T.

    Intermetallic compounds with the CaCu/sub 5/ type of crystal structure, particularly LaNiCo/sub 4/ and CaNi/sub 5/, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen cn produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  3. MS-Electronic Nose Performance Improvement Using GC Retention Times And 2-Way And 3-Way Data Processing Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burian, Cosmin; Llobet, Eduard; Vilanova, Xavier

    We have designed a challenging experimental sample set in the form of 20 solutions with a high degree of similarity in order to study whether the addition of chromatographic separation information improves the performance of regular MS based electronic noses. In order to make an initial study of the approach, two different chromatographic methods were used. By processing the data of these experiments with 2 and 3-way algorithms, we have shown that the addition of chromatographic separation information improves the results compared to the 2-way analysis of mass spectra or total ion chromatogram treated separately. Our findings show that whenmore » the chromatographic peaks are resolved (longer measurement times), 2-way methods work better than 3-way methods, whereas in the case of a more challenging measurement (more coeluted chromatograms, much faster GC-MS measurements) 3-way methods work better.« less

  4. Using Aspen to Teach Chromatographic Bioprocessing: A Case Study in Weak Partitioning Chromatography for Biotechnology Applications

    ERIC Educational Resources Information Center

    Evans, Steven T.; Huang, Xinqun; Cramer, Steven M.

    2010-01-01

    The commercial simulator Aspen Chromatography was employed to study and optimize an important new industrial separation process, weak partitioning chromatography. This case study on antibody purification was implemented in a chromatographic separations course. Parametric simulations were performed to investigate the effect of operating parameters…

  5. Characterization of Gas Chromatographic Liquid Phases Using McReynolds Constants. An Experiment for Instrumental Analysis Laboratory.

    ERIC Educational Resources Information Center

    Erskine, Steven R.; And Others

    1986-01-01

    Describes a laboratory experiment that is designed to aid in the understanding of the fundamental process involved in gas chromatographic separations. Introduces the Kovats retention index system for use by chemistry students to establish criteria for the optimal selection of gas chromatographic stationary phases. (TW)

  6. Developing Inquiry-Based Labs Using Micro-Column Chromatography

    ERIC Educational Resources Information Center

    Barden-Gabbei, Laura M.; Moffitt, Deborah L.

    2006-01-01

    Chromatography is a process by which mixtures can be separated or substances can be purified. Biological and chemical laboratories use many different types of chromatographic processes. For example, the pharmaceutical industry uses chromatographic techniques to purify drugs, medical labs use them to identify blood components such as cholesterol,…

  7. Multi-objective optimization of chromatographic rare earth element separation.

    PubMed

    Knutson, Hans-Kristian; Holmqvist, Anders; Nilsson, Bernt

    2015-10-16

    The importance of rare earth elements in modern technological industry grows, and as a result the interest for developing separation processes increases. This work is a part of developing chromatography as a rare earth element processing method. Process optimization is an important step in process development, and there are several competing objectives that need to be considered in a chromatographic separation process. Most studies are limited to evaluating the two competing objectives productivity and yield, and studies of scenarios with tri-objective optimizations are scarce. Tri-objective optimizations are much needed when evaluating the chromatographic separation of rare earth elements due to the importance of product pool concentration along with productivity and yield as process objectives. In this work, a multi-objective optimization strategy considering productivity, yield and pool concentration is proposed. This was carried out in the frame of a model based optimization study on a batch chromatography separation of the rare earth elements samarium, europium and gadolinium. The findings from the multi-objective optimization were used to provide with a general strategy for achieving desirable operation points, resulting in a productivity ranging between 0.61 and 0.75 kgEu/mcolumn(3), h(-1) and a pool concentration between 0.52 and 0.79 kgEu/m(3), while maintaining a purity above 99% and never falling below an 80% yield for the main target component europium. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Automated gas chromatography

    DOEpatents

    Mowry, C.D.; Blair, D.S.; Rodacy, P.J.; Reber, S.D.

    1999-07-13

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute. 7 figs.

  9. Automated gas chromatography

    DOEpatents

    Mowry, Curtis D.; Blair, Dianna S.; Rodacy, Philip J.; Reber, Stephen D.

    1999-01-01

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute.

  10. Reprocessing system with nuclide separation based on chromatography in hydrochloric acid solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Tatsuya; Tachibana, Yu; Koyama, Shi-ichi

    2013-07-01

    We have proposed the reprocessing system with nuclide separation processes based on the chromatographic technique in the hydrochloric acid solution system. Our proposed system consists of the dissolution process, the reprocessing process, the minor actinide separation process, and nuclide separation processes. In the reprocessing and separation processes, the pyridine resin is used as a main separation media. It was confirmed that the dissolution in the hydrochloric acid solution is easily achieved by the plasma voloxidation and by the addition of oxygen peroxide into the hydrochloric acid solution.

  11. Rapid and Convenient Separation of Chitooligosaccharides by Ion-Exchange Chromatography

    NASA Astrophysics Data System (ADS)

    Wu, Yuxiao; Lu, Wei-Peng; Wang, Jianing; Gao, Yunhua; Guo, Yanchuan

    2017-12-01

    Pervious methods for separation of highly purified chitooligosaccharides was time-consuming and labor-intensive, which limited the large-scale production. This study developed a convenient ion-exchange chromatography using the ÄKTA™ avant 150 chromatographic system. Five fractions were automatically collected under detecting the absorption at 210 nm. The fractions were analyzed by high-performance liquid chromatography. It proved that they primarily comprised chitobiose, chitotriose, chitotetraose, chitopentaose, and chitohexaose, respectively, with chromatographic purities over 90%. The separation process was rapid, convenient and could be monitored on-line, which would be benefit for the mass production of chitooligosaccharides.

  12. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chromatographic separation material for clinical... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2230 Chromatographic separation material for clinical use. (a) Identification. A...

  13. Approaches to High-Performance Preparative Chromatography of Proteins

    NASA Astrophysics Data System (ADS)

    Sun, Yan; Liu, Fu-Feng; Shi, Qing-Hong

    Preparative liquid chromatography is widely used for the purification of chemical and biological substances. Different from high-performance liquid chromatography for the analysis of many different components at minimized sample loading, high-performance preparative chromatography is of much larger scale and should be of high resolution and high capacity at high operation speed and low to moderate pressure drop. There are various approaches to this end. For biochemical engineers, the traditional way is to model and optimize a purification process to make it exert its maximum capability. For high-performance separations, however, we need to improve chromatographic technology itself. We herein discuss four approaches in this review, mainly based on the recent studies in our group. The first is the development of high-performance matrices, because packing material is the central component of chromatography. Progress in the fabrication of superporous materials in both beaded and monolithic forms are reviewed. The second topic is the discovery and design of affinity ligands for proteins. In most chromatographic methods, proteins are separated based on their interactions with the ligands attached to the surface of porous media. A target-specific ligand can offer selective purification of desired proteins. Third, electrochromatography is discussed. An electric field applied to a chromatographic column can induce additional separation mechanisms besides chromatography, and result in electrokinetic transport of protein molecules and/or the fluid inside pores, thus leading to high-performance separations. Finally, expanded-bed adsorption is described for process integration to reduce separation steps and process time.

  14. Chelate-modified polymers for atmospheric gas chromatography

    NASA Technical Reports Server (NTRS)

    Christensen, W. W.; Mayer, L. A.; Woeller, F. H. (Inventor)

    1980-01-01

    Chromatographic materials were developed to serve as the stationary phase of columns used in the separation of atmospheric gases. These materials consist of a crosslinked porous polymer matrix, e.g., a divinylbenzene polymer, into which has been embedded an inorganic complexed ion such as N,N'-ethylene-bis-(acetylacetoniminato)-cobalt (2). Organic nitrogenous bases, such as pyridine, may be incorporated into the chelate polymer complexes to increase their chromatographic utility. With such materials, the process of gas chromatography is greatly simplified, especially in terms of time and quantity of material needed for a gas separation.

  15. Measurement of actinides and strontium-90 in high activity waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, S.L. III; Nelson, M.R.

    1994-08-01

    The reliable measurement of trace radionuclides in high activity waste is important to support waste processing activities at SRS (F and H Area Waste Tanks, Extended Sludge Processing (ESP) and In-Tank precipitation (ITP) processing). Separation techniques are needed to remove high levels of gamma activity and alpha/beta interferences prior to analytical measurement. Using new extraction chromatographic resins from EiChrom Industries, Inc., the SRS Central Laboratory has developed new high speed separation methods that enable measurement of neptunium, thorium, uranium, plutonium, americium and strontium-90 in high activity waste solutions. Small particle size resin and applied vacuum are used to reduce analysismore » times and enhance column performance. Extraction chromatographic resins are easy to use and eliminate the generation of contaminated liquid organic waste.« less

  16. Refined separation of combined Fe–Hf from rock matrices for isotope analyses using AG-MP-1M and Ln-Spec chromatographic extraction resins

    PubMed Central

    Cheng, Ting; Nebel, Oliver; Sossi, Paolo A.; Chen, Fukun

    2014-01-01

    A combined procedure for separating Fe and Hf from a single rock digestion is presented. In a two-stage chromatographic extraction process, a purified Fe fraction is first quantitatively separated from the rock matrix using AG-MP-1M resin in HCl. Hafnium is subsequently isolated using a modified version of a commonly applied method using Eichrom LN-Spec resin. Our combined method includes:•Purification of Fe from the rock matrix using HCl, ready for mass spectrometric analysis.•Direct loading of the matrix onto the resin that is used for Hf purification.•Collection of a Fe-free Hf fraction. PMID:26150946

  17. Magma transport and metasomatism in the mantle: a critical review of current geochemical models

    USGS Publications Warehouse

    Nielson, J.E.; Wilshire, H.G.

    1993-01-01

    Conflicting geochemical models of metasomatic interactions between mantle peridotite and melt all assume that mantle reactions reflect chromatographic processes. Examination of field, petrological, and compositional data suggests that the hypothesis of chromatographic fractionation based on the supposition of large-scale percolative processes needs review and revision. Well-constrained rock and mineral data from xenoliths indicate that many elements that behave incompatibly in equilibrium crystallization processes are absorbed immediately when melts emerge from conduits into depleted peridotite. After reacting to equilibrium with the peridotite, melt that percolates away from the conduit is largely depleted of incompatible elements. Continued addition of melts extends the zone of equilibrium farther from the conduit. Such a process resembles ion-exchange chromatography for H2O purification, rather than the model of chromatographic species separation. -from Authors

  18. Ion Exchange and Thin Layer Chromatographic Separation and Identification of Amino Acids in a Mixture: An Experiment for General Chemistry and Biotechnology Laboratories

    ERIC Educational Resources Information Center

    Brunauer, Linda S.; Caslavka, Katelyn E.; Van Groningen, Karinne

    2014-01-01

    A multiday laboratory exercise is described that is suitable for first-year undergraduate chemistry, biochemistry, or biotechnology students. Students gain experience in performing chromatographic separations of biomolecules, in both a column and thin layer chromatography (TLC) format. Students chromatographically separate amino acids (AA) in an…

  19. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation.

    PubMed

    Beg, Sarwar; Chaudhary, Vandna; Sharma, Gajanand; Garg, Babita; Panda, Sagar Suman; Singh, Bhupinder

    2016-06-01

    The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm. A Box-Behnken design was applied for chromatographic method optimization taking mobile phase ratio, pH and flow rate as the critical method parameters (CMPs) from screening studies. Peak area, retention time, theoretical plates and peak tailing were measured as the critical analytical attributes (CAAs). Further, the bioanalytical liquid-liquid extraction process was optimized using an optimal design by selecting extraction time, centrifugation speed and temperature as the CMPs for percentage recovery of nevirapine as the CAA. The search for an optimum chromatographic solution was conducted through numerical desirability function. Validation studies performed as per the US Food and Drug Administration requirements revealed results within the acceptance limit. In a nutshell, the studies successfully demonstrate the utility of analytical QbD approach for the rational development of a bioanalytical method with enhanced chromatographic separation and recovery of nevirapine in rat plasma. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Extraction chromatographic separation of Am(III) and Eu(III) by TPEN-immobilized gel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeshita, K.; Ogata, T.; Oaki, H.

    2013-07-01

    A TPEN derivative with 4 vinyl groups, N,N,N',N' -tetrakis-(4-propenyloxy-2-pyridylmethyl)ethylenediamine (TPPEN) was synthesized for the separation of trivalent minor actinides (Am(III)) and lanthanides (Eu(III)). A co-polymer gel with TPPEN and N-isopropylacrylamide (NIPA) showed a high separation factor of Am(III) over Eu(III) (SF[Am/Eu]), which was evaluated to be 26 at pH=5. Thin film of NIPA-TPPEN gel (average thickness: 2-40 nm) was immobilized on the pore surface in porous silica particles (particle diameter : 50 μm, average pore diameter : 50 and 300 nm) and a chromatographic column (diameter: 6 mm, height: 11 mm) packed with the gel-coated particles was prepared. A smallmore » amount of weakly acidic solution (pH=4) containing Am(III) and Eu(III) was supplied in the column and the elution tests of Am(III) and Eu(III) were carried out. Eu(III) was recovered separately by a weakly acidic eluent (pH=4) at 313 K and Am(III) by a highly acidic eluent (pH=2) at 298 K. These results suggest that the contentious separation of minor actinides and lanthanides is attainable by a new extraction chromatographic process with two columns adjusted to 298 K and 313 K. (authors)« less

  1. Engineering aspects of rate-related processes in food manufacturing.

    PubMed

    Adachi, Shuji

    2015-01-01

    Many rate-related phenomena occur in food manufacturing processes. This review addresses four of them, all of which are topics that the author has studied in order to design food manufacturing processes that are favorable from the standpoint of food engineering. They include chromatographic separation through continuous separation with a simulated moving adsorber, lipid oxidation kinetics in emulsions and microencapsulated systems, kinetic analysis and extraction in subcritical water, and water migration in pasta.

  2. Nano-fabricated size exclusion chromatograph

    NASA Technical Reports Server (NTRS)

    Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; Castillo, L. del; White, V.

    2002-01-01

    This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

  3. Preparation of polyhedral oligomeric silsesquioxane based hybrid monoliths by ring-opening polymerization for capillary LC and CEC.

    PubMed

    Lin, Hui; Zhang, Zhenbin; Dong, Jing; Liu, Zhongshan; Ou, Junjie; Zou, Hanfa

    2013-09-01

    A new organic-inorganic hybrid monolith was prepared by the ring-opening polymerization of octaglycidyldimethylsilyl polyhedral oligomeric silsesquioxane (POSS) with 1,4-butanediamine (BDA) using 1-propanol, 1,4-butanediol, and PEG 10,000 as a porogenic system. Benefiting from the moderate phase separation process, the resulting poly(POSS-co-BDA) hybrid monolith possessed a uniform microstructure and exhibited excellent performance in chromatographic applications. Neutral, acidic, and basic compounds were successfully separated on the hybrid monolith in capillary LC (cLC), and high column efficiencies were achieved in all of the separations. In addition, as the amino groups could generate a strong EOF, the hybrid monolith was also applied in CEC for the separation of neutral and polar compounds, and a satisfactory performance was obtained. These results demonstrate that the poly(POSS-co-BDA) hybrid monolith is a good separation media in chromatographic separations of various types of compounds by both cLC and CEC. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Multi-mode application of graphene quantum dots bonded silica stationary phase for high performance liquid chromatography.

    PubMed

    Wu, Qi; Sun, Yaming; Zhang, Xiaoli; Zhang, Xia; Dong, Shuqing; Qiu, Hongdeng; Wang, Litao; Zhao, Liang

    2017-04-07

    Graphene quantum dots (GQDs), which possess hydrophobic, hydrophilic, π-π stacking and hydrogen bonding properties, have great prospect in HPLC. In this study, a novel GQDs bonded silica stationary phase was prepared and applied in multiple separation modes including normal phase, reversed phase and hydrophilic chromatography mode. Alkaloids, nucleosides and nucleobases were chosen as test compounds to evaluate the separation performance of this column in hydrophilic chromatographic mode. The tested polar compounds achieved baseline separation and the resolutions reached 2.32, 4.62, 7.79, 1.68 for thymidine, uridine, adenosine, cytidine and guanosine. This new column showed satisfactory chromatographic performance for anilines, phenols and polycyclic aromatic hydrocarbons in normal and reversed phase mode. Five anilines were completely separated within 10min under the condition of mobile phase containing only 10% methanol. The effect of water content, buffer concentration and pH on chromatographic separation was further investigated, founding that this new stationary phase showed a complex retention mechanism of partitioning, adsorption and electrostatic interaction in hydrophilic chromatography mode, and the multiple retention interactions such as π-π stacking and π-π electron-donor-acceptor interaction played an important role during the separation process. This GQDs bonded column, which allows us to adjust appropriate chromatography mode according to the properties of analytes, has possibility in actual application after further research. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. 3D-liquid chromatography as a complex mixture characterization tool for knowledge-based downstream process development.

    PubMed

    Hanke, Alexander T; Tsintavi, Eleni; Ramirez Vazquez, Maria Del Pilar; van der Wielen, Luuk A M; Verhaert, Peter D E M; Eppink, Michel H M; van de Sandt, Emile J A X; Ottens, Marcel

    2016-09-01

    Knowledge-based development of chromatographic separation processes requires efficient techniques to determine the physicochemical properties of the product and the impurities to be removed. These characterization techniques are usually divided into approaches that determine molecular properties, such as charge, hydrophobicity and size, or molecular interactions with auxiliary materials, commonly in the form of adsorption isotherms. In this study we demonstrate the application of a three-dimensional liquid chromatography approach to a clarified cell homogenate containing a therapeutic enzyme. Each separation dimension determines a molecular property relevant to the chromatographic behavior of each component. Matching of the peaks across the different separation dimensions and against a high-resolution reference chromatogram allows to assign the determined parameters to pseudo-components, allowing to determine the most promising technique for the removal of each impurity. More detailed process design using mechanistic models requires isotherm parameters. For this purpose, the second dimension consists of multiple linear gradient separations on columns in a high-throughput screening compatible format, that allow regression of isotherm parameters with an average standard error of 8%. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:1283-1291, 2016. © 2016 American Institute of Chemical Engineers.

  6. Gas Chromatographic Separation of an Acetylene Vinyl Fluoride-Difluoroethane Mixture on Triethylene Glycol and Silicone Oil,

    DTIC Science & Technology

    The purpose of the research was to study gas-chromatographic separation of impurities of acetylene and difluoroethane in vinyl fluoride obtained by...and difluoroethane . All the components are separated, and the criteria of separation of acetylene-vinyl fluoride and vinyl fluoride- difluoroethane

  7. Characterization of new types of stationary phases for fast and ultra-fast liquid chromatography by signal processing based on AutoCovariance Function: a case study of application to Passiflora incarnata L. extract separations.

    PubMed

    Pietrogrande, Maria Chiara; Dondi, Francesco; Ciogli, Alessia; Gasparrini, Francesco; Piccin, Antonella; Serafini, Mauro

    2010-06-25

    In this study, a comparative investigation was performed of HPLC Ascentis (2.7 microm particles) columns based on fused-core particle technology and Acquity (1.7 microm particles) columns requiring UPLC instruments, in comparison with Chromolith RP-18e columns. The study was carried out on mother and vegetal tinctures of Passiflora incarnata L. on one single or two coupled columns. The fundamental attributions of the chromatographic profiles are evaluated using a chemometric procedure, based on the AutoCovariance Function (ACVF). Different chromatographic systems are compared in terms of their separation parameters, i.e., number of total chemical components (m(tot)), separation efficiency (sigma), peak capacity (n(c)), overlap degree of peaks and peak purity. The obtained results show the improvements achieved by HPLC columns with narrow size particles in terms of total analysis time and chromatographic efficiency: comparable performance are achieved by Ascentis (2.7 microm particle) column and Acquity (1.7 microm particle) column requiring UPLC instruments. The ACVF plot is proposed as a simplified tool describing the chromatographic fingerprint to be used for evaluating and comparing chemical composition of plant extracts by using the parameters D% - relative abundance of the deterministic component - and c(EACF) - similarity index computed on ACVF. Copyright 2010 Elsevier B.V. All rights reserved.

  8. LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF TRANS-CHLORDANE, CIS-CHLORDANE, HEPTACHLOR, HEPTACHLOR EPOXIDE AND ALPHA-HEXACHLOROCYCLOHEXANE WITH APPLICATION TO SMALL-SCALE PREPARATIVE SEPARATION

    EPA Science Inventory

    Analytical high-performance liquid chromatographic separations of the individual enantiomers of five polychlorinated compounds were obtained on polysaccharide stereoselective HPLC columns. The enantiomers of the pesticides trans-chlordane, cis-chlordane and heptachlor were separa...

  9. Studies on improved integrated membrane-based chromatographic process for bioseparation

    NASA Astrophysics Data System (ADS)

    Xu, Yanke

    To improve protein separation and purification directly from a fermentation broth, a novel membrane filtration-cum-chromatography device configuration having a relatively impermeable coated zone near the hollow fiber module outlet has been developed. The integrated membrane filtration-cum-chromatography unit packed with chromatographic beads on the shell side of the hollow fiber unit enjoys the advantages of both membrane filtration and chromatography; it allows one to load the chromatographic media directly from the fermentation broth or lysate and separate the adsorbed proteins through the subsequent elution step in a cyclic process. Interfacial polymerization was carried out to coat the bottom section of the hollow fiber membrane while leaving the rest of the hollow fiber membrane unaffected. Myoglobin (Mb), bovine serum albumin (BSA) and a-lactalbumin (a-LA) were used as model proteins in binary mixtures. Separation behaviors of binary protein mixtures were studied in devices using either an ultrafiltration (UF) membrane or a microfiltration (MF) membrane. Experimental results show that the breakthrough time and the protein loading capacities were dramatically improved after coating in both UF and MF modules. For a synthetic yeast fermentation broth feed, the Mb and a-LA elution profiles for the four consecutive cyclic runs were almost superimposable. Due to the lower transmembrane flux in this device plus the periodical washing-elution during the chromatographic separation, fouling was not a problem as it is in conventional microfiltration. A mathematical model describing the hydrodynamic and protein loading behaviors of the integrated device using UF membrane with a coated zone was developed. The simulation results for the breakthrough agree well with the experimental breakthrough curves. The optimal length of the coated zone was obtained from the simulation. A theoretical analysis of the protein mass transfer was performed using a diffusion-convection model considering the feed-side concentration polarization and the permeate-side concentration gradient formed by the adsorption. The permeate-side adsorption can enhance the observed protein transmission through the membrane considerably at low permeate flux. But the enhancement effect can be neglected at higher permeate flux when convection dominates the total mass transfer process or the proteins are very highly rejected by the membrane.

  10. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    USGS Publications Warehouse

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  11. Chromatographic separation of radioactive noble gases from xenon

    NASA Astrophysics Data System (ADS)

    Akerib, D. S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bramante, R.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Coffey, T.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Pech, K.; Phelps, P.; Reichhart, L.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Yazdani, K.; Young, S. K.; Zhang, C.

    2018-01-01

    The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85Kr and 39Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search experiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

  12. Chromatographic separation of radioactive noble gases from xenon

    DOE PAGES

    Akerib, DS; Araújo, HM; Bai, X; ...

    2017-10-31

    The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopesmore » $$^{85}$$Kr and $$^{39}$$Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search exmperiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.« less

  13. Deconvolution of gas chromatographic data

    NASA Technical Reports Server (NTRS)

    Howard, S.; Rayborn, G. H.

    1980-01-01

    The use of deconvolution methods on gas chromatographic data to obtain an accurate determination of the relative amounts of each material present by mathematically separating the merged peaks is discussed. Data were obtained on a gas chromatograph with a flame ionization detector. Chromatograms of five xylenes with differing degrees of separation were generated by varying the column temperature at selected rates. The merged peaks were then successfully separated by deconvolution. The concept of function continuation in the frequency domain was introduced in striving to reach the theoretical limit of accuracy, but proved to be only partially successful.

  14. Evaluation of center-cut separations applying simulated moving bed chromatography with 8 zones.

    PubMed

    Santos da Silva, Francisco Vitor; Seidel-Morgenstern, Andreas

    2016-07-22

    Different multi-column options to perform continuous chromatographic separations of ternary mixtures have been proposed in order to overcome limitations of batch chromatography. One attractive option is given by simulated moving bed chromatography (SMB) with 8 zones, a process that offers uninterrupted production, and, potentially, improved economy. As in other established ternary separation processes, the separation sequence is crucial for the performance of the process. This problem is addressed here by computing and comparing optimal performances of the two possibilities assuming linear adsorption isotherms. The conclusions are presented in a decision tree which can be used to guide the selection of system configuration and operation. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Chromatographic separation of the theranostic radionuclide 111Ag from a proton irradiated thorium matrix

    DOE PAGES

    Mastren, Tara; Radchenko, Valery; Engle, Jonathan W.; ...

    2017-10-30

    Column chromatographic methods have been developed to separate no-carrier-added 111Ag from proton irradiated thorium targets and associated fission products as an ancillary process to an existing 225Ac separation design. In this paper, we report the separation of 111Ag both prior and subsequent to 225Ac recovery using CL resin, a solvent impregnated resin (SIR) that carries an organic solution of alkyl phosphine sulfides (R 3P = S) and alkyl phosphine oxides (R 3P = O). The recovery yield of 111Ag was 93 ± 9% with a radiochemical purity of 99.9% (prior) and 87 ± 9% with a radiochemical purity of 99.9%more » (subsequent to) 225Ac recovery. Both processes were successfully performed with insignificant impacts on 225Ac yields or quality. Measured equilibrium distribution coefficients for silver and ruthenium (a residual contaminant) on CL resin in hydrochloric and nitric acid media are reported, to the best of our knowledge, for the first time. Finally and additionally, measured cross sections for the production of 111Ag and 110mAg for the 232Th(p,f) 110m,111Ag reactions are reported within.« less

  16. Chromatographic separation of the theranostic radionuclide 111Ag from a proton irradiated thorium matrix

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mastren, Tara; Radchenko, Valery; Engle, Jonathan W.

    Column chromatographic methods have been developed to separate no-carrier-added 111Ag from proton irradiated thorium targets and associated fission products as an ancillary process to an existing 225Ac separation design. In this paper, we report the separation of 111Ag both prior and subsequent to 225Ac recovery using CL resin, a solvent impregnated resin (SIR) that carries an organic solution of alkyl phosphine sulfides (R 3P = S) and alkyl phosphine oxides (R 3P = O). The recovery yield of 111Ag was 93 ± 9% with a radiochemical purity of 99.9% (prior) and 87 ± 9% with a radiochemical purity of 99.9%more » (subsequent to) 225Ac recovery. Both processes were successfully performed with insignificant impacts on 225Ac yields or quality. Measured equilibrium distribution coefficients for silver and ruthenium (a residual contaminant) on CL resin in hydrochloric and nitric acid media are reported, to the best of our knowledge, for the first time. Finally and additionally, measured cross sections for the production of 111Ag and 110mAg for the 232Th(p,f) 110m,111Ag reactions are reported within.« less

  17. Assessing the varietal origin of extra-virgin olive oil using liquid chromatography fingerprints of phenolic compound, data fusion and chemometrics.

    PubMed

    Bajoub, Aadil; Medina-Rodríguez, Santiago; Gómez-Romero, María; Ajal, El Amine; Bagur-González, María Gracia; Fernández-Gutiérrez, Alberto; Carrasco-Pancorbo, Alegría

    2017-01-15

    High Performance Liquid Chromatography (HPLC) with diode array (DAD) and fluorescence (FLD) detection was used to acquire the fingerprints of the phenolic fraction of monovarietal extra-virgin olive oils (extra-VOOs) collected over three consecutive crop seasons (2011/2012-2013/2014). The chromatographic fingerprints of 140 extra-VOO samples processed from olive fruits of seven olive varieties, were recorded and statistically treated for varietal authentication purposes. First, DAD and FLD chromatographic-fingerprint datasets were separately processed and, subsequently, were joined using "Low-level" and "Mid-Level" data fusion methods. After the preliminary examination by principal component analysis (PCA), three supervised pattern recognition techniques, Partial Least Squares Discriminant Analysis (PLS-DA), Soft Independent Modeling of Class Analogies (SIMCA) and K-Nearest Neighbors (k-NN) were applied to the four chromatographic-fingerprinting matrices. The classification models built were very sensitive and selective, showing considerably good recognition and prediction abilities. The combination "chromatographic dataset+chemometric technique" allowing the most accurate classification for each monovarietal extra-VOO was highlighted. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Chromatographic Separation of Cd from Plants via Anion-Exchange Resin for an Isotope Determination by Multiple Collector ICP-MS.

    PubMed

    Wei, Rongfei; Guo, Qingjun; Wen, Hanjie; Peters, Marc; Yang, Junxing; Tian, Liyan; Han, Xiaokun

    2017-01-01

    In this study, key factors affecting the chromatographic separation of Cd from plants, such as the resin column, digestion and purification procedures, were experimentally investigated. A technique for separating Cd from plant samples based on single ion-exchange chromatography has been developed, which is suitable for the high-precision analysis of Cd isotopes by multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The robustness of the technique was assessed by replicate analyses of Cd standard solutions and plant samples. The Cd yields of the whole separation process were higher than 95%, and the 114/110 Cd values of three Cd second standard solutions (Münster Cd, Spex Cd, Spex-1 Cd solutions) relative to the NIST SRM 3108 were measured accurately, which enabled the comparisons of Cd isotope results obtained in other laboratories. Hence, stable Cd isotope analyses represent a powerful tool for fingerprinting specific Cd sources and/or examining biogeochemical reactions in ecological and environmental systems.

  19. Partial least squares model and design of experiments toward the analysis of the metabolome of Jatropha gossypifolia leaves: Extraction and chromatographic fingerprint optimization.

    PubMed

    Pilon, Alan Cesar; Carnevale Neto, Fausto; Freire, Rafael Teixeira; Cardoso, Patrícia; Carneiro, Renato Lajarim; Da Silva Bolzani, Vanderlan; Castro-Gamboa, Ian

    2016-03-01

    A major challenge in metabolomic studies is how to extract and analyze an entire metabolome. So far, no single method was able to clearly complete this task in an efficient and reproducible way. In this work we proposed a sequential strategy for the extraction and chromatographic separation of metabolites from leaves Jatropha gossypifolia using a design of experiments and partial least square model. The effect of 14 different solvents on extraction process was evaluated and an optimized separation condition on liquid chromatography was estimated considering mobile phase composition and analysis time. The initial conditions of extraction using methanol and separation in 30 min between 5 and 100% water/methanol (1:1 v/v) with 0.1% of acetic acid, 20 μL sample volume, 3.0 mL min(-1) flow rate and 25°C column temperature led to 107 chromatographic peaks. After the optimization strategy using i-propanol/chloroform (1:1 v/v) for extraction, linear gradient elution of 60 min between 5 and 100% water/(acetonitrile/methanol 68:32 v/v with 0.1% of acetic acid), 30 μL sample volume, 2.0 mL min(-1) flow rate, and 30°C column temperature, we detected 140 chromatographic peaks, 30.84% more peaks compared to initial method. This is a reliable strategy using a limited number of experiments for metabolomics protocols. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Chromatographic extraction with di(2-ethylhexyl)orthophosphoric acid for production and purification of promethium-147

    DOEpatents

    Boll, Rose A [Knoxville, TN; Mirzadeh, Saed [Knoxville, TN

    2008-10-14

    A method of producing and purifying promethium-147 including the steps of: irradiating a target material including neodymium-146 with neutrons to produce promethium-147 within the irradiated target material; dissolving the irradiated target material to form an acidic solution; loading the acidic solution onto a chromatographic separation apparatus containing HDEHP; and eluting the apparatus to chromatographically separate the promethium-147 from the neodymium-146.

  1. Method for the chromatographic separation of cations from aqueous samples

    DOEpatents

    Horwitz, E.P.; Chiarizia, R.; Dietz, M.L.

    1997-07-29

    An extraction chromatographic material is described for extracting metal cations from a liquid stream. The extraction chromatographic material is prepared by adsorbing a diesterified methanediphosphonic acid on an inert particulate support. 7 figs.

  2. HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF ORGANOPHOSPHORUS PESTICIDES ON POLYSACCHARIDE CHIRAL STATIONARY PHASES

    EPA Science Inventory

    High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) was obtained on polysaccharide enantioselective HPLC columns using alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, fonofos, fenamiph...

  3. A Small-Scale Low-Cost Gas Chromatograph

    ERIC Educational Resources Information Center

    Gros, Natasa; Vrtacnik, Margareta

    2005-01-01

    The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.

  4. Method for the chromatographic separation of cations from aqueous samples

    DOEpatents

    Horwitz, E.P.; Chiarizia, R.; Dietz, M.L.

    1998-12-22

    An extraction chromatographic material is described for extracting metal cations from a liquid stream. The extraction chromatographic material is prepared by adsorbing a diesterified methane-diphosphonic acid on an inert particulate support. 7 figs.

  5. Mixed C18 and C1 modification on an optical fiber for chromatographic sensing.

    PubMed

    Zhou, Leiji; Wang, Kemin; Zuo, Xinbing; Choi, Martin M F; Chen, Yunqing; Huang, Shasheng

    2003-09-01

    An optical fiber-chromatographic sensor, aiming at simultaneous and selective response to multiple components following a chromatographic separation, is described. We report an improved approach for immobilization of octadecyl (C(18)) and methyl (C(1)) moieties as stationary phase on an optical fiber suitable as a sensing phase for organic solutes. By this approach, the stability and lifetime of the sensing layer as well as the detectability and retention behavior of the chromatographic sensor could be improved. Infrared spectroscopy was employed to confirm the presence of C(18) and C(1) moieties on the modified surface of the optical fiber. The chromatographic sensor was applied, with good sensitivity and chemical selectivity, to the simultaneous separation and detection of bromobenzene and toluene, using water as the mobile phase.

  6. Microfluidic thread based electroanalytical system for green chromatographic separations.

    PubMed

    Agustini, Deonir; Fedalto, Lucas; Bergamini, Márcio F; Marcolino-Junior, Luiz Humberto

    2018-02-13

    The use of miniaturized chromatographic systems is an important strategy for reducing the consumption of supplies related to separations, allowing the development of more sustainable analytical methodologies. However, the high cost and complexity in the production of these systems combined with the operational difficulties and the need for the use of solvent and sample pretreatment are challenges to be overcome in order to make the chromatographic methods greener. Here, we report the construction and development of a low cost microfluidic system for green and solvent-free chromatographic separations with electrochemical detection integrated into cotton threads without the use of any mechanical pumping to transport the solutions. The manufacture of the proposed system was performed by simple assembly of the components, with the separation of the species based on an ion exchange mechanism and detection using gold electrodes manufactured directly on the cotton threads. A linear range of 0.025-5.0 mM was obtained for the effective separation of ascorbic acid (AA) and dopamine (DA) with detection limits of 2.89 μM (for AA) and 4.41 μM (for DA). Each analysis was performed at a low cost (less than 0.01 dollars), and with a small volume of waste generated (107.1 μL). So, the proposed system was successfully employed to determine the levels of AA and DA present in the tears of healthy volunteers without sample pretreatment, indicating the good analytical performance of the system and the possibility of performing greener chromatographic separations.

  7. Method for preparing high specific activity 177Lu

    DOEpatents

    Mirzadeh, Saed; Du, Miting; Beets, Arnold L.; Knapp, Jr., Furn F.

    2004-04-06

    A method of separating lutetium from a solution containing Lu and Yb, particularly reactor-produced .sup.177 Lu and .sup.177 Yb, includes the steps of: providing a chromatographic separation apparatus containing LN resin; loading the apparatus with a solution containing Lu and Yb; and eluting the apparatus to chromatographically separate the Lu and the Yb in order to produce high-specific-activity .sup.177 Yb.

  8. Optimization of startup and shutdown operation of simulated moving bed chromatographic processes.

    PubMed

    Li, Suzhou; Kawajiri, Yoshiaki; Raisch, Jörg; Seidel-Morgenstern, Andreas

    2011-06-24

    This paper presents new multistage optimal startup and shutdown strategies for simulated moving bed (SMB) chromatographic processes. The proposed concept allows to adjust transient operating conditions stage-wise, and provides capability to improve transient performance and to fulfill product quality specifications simultaneously. A specially tailored decomposition algorithm is developed to ensure computational tractability of the resulting dynamic optimization problems. By examining the transient operation of a literature separation example characterized by nonlinear competitive isotherm, the feasibility of the solution approach is demonstrated, and the performance of the conventional and multistage optimal transient regimes is evaluated systematically. The quantitative results clearly show that the optimal operating policies not only allow to significantly reduce both duration of the transient phase and desorbent consumption, but also enable on-spec production even during startup and shutdown periods. With the aid of the developed transient procedures, short-term separation campaigns with small batch sizes can be performed more flexibly and efficiently by SMB chromatography. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Chromatographic separation material for clinical use. 862.2230 Section 862.2230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical...

  10. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chromatographic separation material for clinical use. 862.2230 Section 862.2230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical...

  11. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Chromatographic separation material for clinical use. 862.2230 Section 862.2230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical...

  12. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Chromatographic separation material for clinical use. 862.2230 Section 862.2230 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical...

  13. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    ERIC Educational Resources Information Center

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  14. Three-way principal component analysis of the volatile fraction by HS-SPME/GC of aceto balsamico tradizionale of modena.

    PubMed

    Cocchi, Marina; Durante, Caterina; Grandi, Margherita; Manzini, Daniela; Marchetti, Andrea

    2008-01-15

    The present research is aimed at monitoring the evolution of the volatile organic compounds of different samples of aceto balsamico tradizionale of modena (ABTM) during ageing. The flavouring compounds, headspace fraction, of the vinegars of four batterie were sampled by solid phase microextraction technique (SPME), and successively analysed by gas chromatography. Obtaining a data set characterized by different sources of variability such as, different producers, samples of different age and chromatographic profile. The gas chromatographic signals were processed by a three-way data analysis method (Tucker3), which allows an easy visualisation of the data by furnishing a distinct set of graphs for each source of variability. The obtained results indicate that the samples can be separated according to their age highlighting the chemical constituents, which play a major role for their differentiation. The present study represents an example of how the application of Tucker3 models, on gas chromatographic signals may help to follow the transformation processes of food products.

  15. Industrial Membrane Filtration and Short-bed Fractal Separation Systems for Separating Monomers from Heterogeneous Plant Material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kearney, M; Kochergin, V; Hess, R

    2005-03-31

    Large-scale displacement of petroleum will come from low-cost cellulosic feedstocks such as straw and corn stover crop residues. This project has taken a step toward making this projection a reality by reducing capital and energy costs, the two largest cost factors associated with converting cellulosic biomass to chemicals and fuels. The technology exists for using acid or enzyme hydrolysis processes to convert biomass feedstock (i.e., waste cellulose such as straw, corn stover, and wood) into their base monomeric sugar building blocks, which can, in turn, be processed into chemicals and fuels using a number of innovative fermentation technologies. However, whilemore » these processes are technically possible, practical and economic barriers make these processes only marginally feasible or not feasible at all. These barriers are due in part to the complexity and large fixed and recurring capital costs of unit operations including filtration, chromatographic separation, and ion exchange. This project was designed to help remove these barriers by developing and implementing new purification and separation technologies that will reduce the capital costs of the purification and chromatographic separation units by 50% to 70%. The technologies fundamental to these improvements are: (a) highly efficient clarification and purification systems that use screening and membrane filtration to eliminate suspended solids and colloidal material from feed streams and (b) fractal technology based chromatographic separation and ion exchange systems that can substitute for conventional systems but at much smaller size and cost. A non-hazardous ''raw sugar beet juice'' stream (75 to 100 gal/min) was used for prototype testing of these technologies. This raw beet juice stream from the Amalgamated Sugar LLC plant in Twin Falls, Idaho contained abrasive materials and membrane foulants. Its characteristics were representative of an industrial-scale heterogeneous plant extract/hydrolysis stream, and therefore was an ideal model system for developing new separation equipment. Subsequent testing used both synthetic acid hydrolysate and corn stover derived weak acid hydrolysate (NREL produced). A two-phased approach was used for the research and development described in this project. The first level of study involved testing the new concepts at the bench level. The bench-scale evaluations provided fundamental understanding of the processes, building and testing small prototype systems, and determining the efficiency of the novel processes. The second level of study, macro-level, required building larger systems that directly simulated industrial operations and provided validation of performance to minimize financial risk during commercialization. The project goals and scope included: (1) Development of low-capital alternatives to conventional crop-based purification/separation processes; and (2) Development of each process to the point that transition to commercial operation is low risk. The project reporting period was January 2001 to December 2004. This included a one year extension of the project (without additional funding).« less

  16. Rapid fusion method for the determination of Pu, Np, and Am in large soil samples

    DOE PAGES

    Maxwell, Sherrod L.; Culligan, Brian; Hutchison, Jay B.; ...

    2015-02-14

    A new rapid sodium hydroxide fusion method for the preparation of 10-20 g soil samples has been developed by the Savannah River National Laboratory (SRNL). The method enables lower detection limits for plutonium, neptunium, and americium in environmental soil samples. The method also significantly reduces sample processing time and acid fume generation compared to traditional soil digestion techniques using hydrofluoric acid. Ten gram soil aliquots can be ashed and fused using the new method in 1-2 hours, completely dissolving samples, including refractory particles. Pu, Np and Am are separated using stacked 2mL cartridges of TEVA and DGA Resin and measuredmore » using alpha spectrometry. The method can be adapted for measurement by inductively-coupled plasma mass spectrometry (ICP-MS). Two 10 g soil aliquots of fused soil may be combined prior to chromatographic separations to further improve detection limits. Total sample preparation time, including chromatographic separations and alpha spectrometry source preparation, is less than 8 hours.« less

  17. Identification of alkyl carbazoles and alkyl benzocarbazoles in Brazilian petroleum derivatives.

    PubMed

    Oliveira, Eniz Conceição; Vaz de Campos, Maria Cecília; Rodrigues, Maria Regina Alves; Pérez, Valéria Flores; Melecchi, Maria Inês Soares; Vale, Maria Goreti Rodrigues; Zini, Cláudia Alcaraz; Caramão, Elina Bastos

    2006-02-10

    Carbozoles are important compounds in crude oils, as they may be used as geochemical tracers, being the major type of nitrogen compounds in petroleum. At the same time, they are regarded as undesirable due to the problems they may cause in the refining process, such as catalyst poisoning, corrosion, gum or color formation in final products. As separation and identification of carbazoles are challenging goals, this work presents a chromatographic method, made of a pre-fractionation on neutral alumina followed by the separation and identification of two classes of carbazoles using FeCl(3)/Chromossorb W and gas chromatograph with mass spectrometer (GC/MS) (SIM-single ion monitoring mode) analysis. For the first time, a series of alkyl carbazoles and alkyl benzocarbazoles were identified in heavy gas oil (HGO) and atmospheric residue of distillation (ARD) obtained from Brazilian petroleum.

  18. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    PubMed

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Fast assessment of planar chromatographic layers quality using pulse thermovision method.

    PubMed

    Suszyński, Zbigniew; Świta, Robert; Loś, Joanna; Zarzycka, Magdalena B; Kaleniecka, Aleksandra; Zarzycki, Paweł K

    2014-12-19

    The main goal of this paper is to demonstrate capability of pulse thermovision (thermal-wave) methodology for sensitive detection of photothermal non-uniformities within light scattering and semi-transparent planar stationary phases. Successful visualization of stationary phases defects required signal processing protocols based on wavelet filtration, correlation analysis and k-means 3D segmentation. Such post-processing data handling approach allows extremely sensitive detection of thickness and structural changes within commercially available planar chromatographic layers. Particularly, a number of TLC and HPTLC stationary phases including silica, cellulose, aluminum oxide, polyamide and octadecylsilane coated with adsorbent layer ranging from 100 to 250μm were investigated. Presented detection protocol can be used as an efficient tool for fast screening the overall heterogeneity of any layered materials. Moreover, described procedure is very fast (few seconds including acquisition and data processing) and may be applied for fabrication processes online controlling. In spite of planar chromatographic plates this protocol can be used for assessment of different planar separation tools like paper based analytical devices or micro total analysis systems, consisted of organic and non-organic layers. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. The gas-chromatographic and gas-chromatographic-mass-spectrometric identification of halogen-containing organic compounds

    NASA Astrophysics Data System (ADS)

    Gidaspov, B. V.; Zenkevich, I. G.; Rodin, A. A.

    1989-09-01

    The problem of identifying halogen-containing organic compounds in their gas-chromatographic and gas-chromatographic-mass-spectrometric (GC-MS) determination in different materials has been examined. Particular attention has been paid not to the complete characterisation of methods for carrying out this analysis but to the most important problem of increasing the selectivity at the stages of sampling, separation, and interpretation of the gas-chromatographic and GC-MS information. The bibliography contains 292 references.

  1. Research on technology of online gas chromatograph for SF6 decomposition products

    NASA Astrophysics Data System (ADS)

    Li, L.; Fan, X. P.; Zhou, Y. Y.; Tang, N.; Zou, Z. L.; Liu, M. Z.; Huang, G. J.

    2017-12-01

    Sulfur hexafluoride (SF6) decomposition products were qualitatively and quantitatively analyzed by several gas chromatographs in the laboratory. Test conditions and methods were selected and optimized to minimize and eliminate the SF6’ influences on detection of other trace components. The effective separation and detection of selected characteristic gases were achieved. And by comparison among different types of gas chromatograph, it was found that GPTR-S101 can effectively separate and detect SF6 decomposition products and has best the best detection limit and sensitivity. On the basis of GPTR-S101, online gas chromatograph for SF6decomposition products (GPTR-S201) was developed. It lays the foundation for further online monitoring and diagnosis of SF6.

  2. Integrated Extraction Chromatographic Separation of the Lithophile Elements Involved in Long-Lived Radiogenic Isotope Systems (Rb-Sr, U-Th-Pb, Sm-Nd, La-Ce, and Lu-Hf) Useful in Geochemical and Environmental Sciences.

    PubMed

    Pin, Christian; Gannoun, Abdelmouhcine

    2017-02-21

    A fast and efficient sample preparation method in view of isotope ratio measurements is described, allowing the separation of 11 elements involved, either as "parent" or as "daughter" isotopes, in six radiogenic isotope systems used as chronometers and tracers in earth, planetary, and environmental sciences. The protocol is based on small extraction chromatographic columns, used either alone or in tandem, through which a single nitric acid solution is passed, without any intervening evaporation step. The columns use commercially available extraction resins (Sr resin, TRU resin, Ln resin, RE resin, and again Ln resin for isolating Sr and Pb, LREE then La-Ce-Nd-Sm, Lu(Yb), and Hf, Th, and U, respectively) along with an additional, in-house prepared resin for separating Rb. A simplified scheme is proposed for samples requiring the separation of Sr, Pb, Nd, and Hf only. Adverse effects of troublesome major elements (Fe 3+ , Ti) are circumvented by masking with ascorbic acid and hydrofluoric acid, respectively. Typical recoveries in the 85-95% range are achieved, with procedural blanks of 10-100 pg, negligible with regard to the amounts of analytes processed. The fractions separated are suitable for high precision isotope ratio measurements by TIMS or MC-ICP-MS, as demonstrated by the repeat analyses of several international reference materials of basaltic composition for 87 Sr/ 86 Sr, 208,207,206 Pb/ 204 Pb, 143 Nd/ 144 Nd, 176 Hf/ 177 Hf, and 230 Th/ 232 Th. Concentration data could be obtained by spiking and equilibrating the sample with appropriate isotopic tracers before the onset of the separation process and, finally, measuring the isotope ratios modified by the isotope dilution process.

  3. Integrated multiplexed capillary electrophoresis system

    DOEpatents

    Yeung, Edward S.; Tan, Hongdong

    2002-05-14

    The present invention provides an integrated multiplexed capillary electrophoresis system for the analysis of sample analytes. The system integrates and automates multiple components, such as chromatographic columns and separation capillaries, and further provides a detector for the detection of analytes eluting from the separation capillaries. The system employs multiplexed freeze/thaw valves to manage fluid flow and sample movement. The system is computer controlled and is capable of processing samples through reaction, purification, denaturation, pre-concentration, injection, separation and detection in parallel fashion. Methods employing the system of the invention are also provided.

  4. Direct screening and confirmation of priority volatile organic pollutants in drinking water.

    PubMed

    Caro, J; Serrano, A; Gallego, M

    2007-01-05

    A screening tool was proposed for the rapid detection of eight priority volatile organic pollutants according to European standards in drinking water. The method is based on the direct coupling of a headspace sampler with a mass spectrometer, using a chromatographic column heated to 175 degrees C as an interface. The water sample was subjected to the headspace extraction process and the volatile fraction was introduced directly into the mass spectrometer, without prior chromatographic separation, achieving low detection limits (0.6-1.2 ng/ml) for all compounds. The mass spectrum resulting from the simultaneous ionization and fragmentation of the mixture of molecules constitutes the volatile profile of each sample. An appropriate chemometric treatment of these signals permitted them to be classified, on the basis of their volatile composition, as contaminated or uncontaminated with respect to the legally established concentration levels for these compounds in drinking water, and providing no false negatives. A conventional confirmation method was carried out to analyze positive water samples by using the same instrumental setup as in the screening method, but using an appropriate temperature program in the chromatographic column to separate, identify and quantify each analyte.

  5. Avoiding Misannotation of In-Source Fragmentation Products as Cellular Metabolites in Liquid Chromatography–Mass Spectrometry-Based Metabolomics

    DOE PAGES

    Xu, Yi-Fan; Lu, Wenyun; Rabinowitz, Joshua D.

    2015-01-15

    Liquid chromatography–mass spectrometry (LC-MS) technology allows for rapid quantitation of cellular metabolites, with metabolites identified by mass spectrometry and chromatographic retention time. Recently, with the development of rapid scanning high-resolution high accuracy mass spectrometers and the desire for high throughput screening, minimal or no chromatographic separation has become increasingly popular. Furthermore, when analyzing complex cellular extracts, however, the lack of chromatographic separation could potentially result in misannotation of structurally related metabolites. Here, we show that, even using electrospray ionization, a soft ionization method, in-source fragmentation generates unwanted byproducts of identical mass to common metabolites. For example, nucleotide-triphosphates generate nucleotide-diphosphates, andmore » hexose-phosphates generate triose-phosphates. We also evaluated yeast intracellular metabolite extracts and found more than 20 cases of in-source fragments that mimic common metabolites. Finally and accordingly, chromatographic separation is required for accurate quantitation of many common cellular metabolites.« less

  6. Liquid chromatographic separation of terpenoid pigments in foods and food products.

    PubMed

    Cserháti, T; Forgács, E

    2001-11-30

    The newest achievements in the use of various liquid chromatographic techniques such as adsorption and reversed-phase thin-layer chromatography and HPLC employed for the separation and quantitative determination of terpenoid-based color substances in foods and food products are reviewed. The techniques applied for the analysis of individual pigments and pigments classes are surveyed and critically evaluated. Future trends in the separation and identification of pigments in foods and food products are delineated.

  7. Reversed-phase thin-layer chromatography of homologs of Antimycin-A and related derivatives

    USGS Publications Warehouse

    Abidi, Sharon L.

    1989-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  8. How Much Can We Learn from a Single Chromatographic Experiment? A Bayesian Perspective.

    PubMed

    Wiczling, Paweł; Kaliszan, Roman

    2016-01-05

    In this work, we proposed and investigated a Bayesian inference procedure to find the desired chromatographic conditions based on known analyte properties (lipophilicity, pKa, and polar surface area) using one preliminary experiment. A previously developed nonlinear mixed effect model was used to specify the prior information about a new analyte with known physicochemical properties. Further, the prior (no preliminary data) and posterior predictive distribution (prior + one experiment) were determined sequentially to search towards the desired separation. The following isocratic high-performance reversed-phase liquid chromatographic conditions were sought: (1) retention time of a single analyte within the range of 4-6 min and (2) baseline separation of two analytes with retention times within the range of 4-10 min. The empirical posterior Bayesian distribution of parameters was estimated using the "slice sampling" Markov Chain Monte Carlo (MCMC) algorithm implemented in Matlab. The simulations with artificial analytes and experimental data of ketoprofen and papaverine were used to test the proposed methodology. The simulation experiment showed that for a single and two randomly selected analytes, there is 97% and 74% probability of obtaining a successful chromatogram using none or one preliminary experiment. The desired separation for ketoprofen and papaverine was established based on a single experiment. It was confirmed that the search for a desired separation rarely requires a large number of chromatographic analyses at least for a simple optimization problem. The proposed Bayesian-based optimization scheme is a powerful method of finding a desired chromatographic separation based on a small number of preliminary experiments.

  9. Development of micromachined preconcentrators and gas chromatographic separation columns by an electroless gold plating technology

    NASA Astrophysics Data System (ADS)

    Kuo, C.-Y.; Chen, P.-S.; Chen, H.-T.; Lu, C.-J.; Tian, W.-C.

    2017-03-01

    In this study, a simple process for fabricating a novel micromachined preconcentrator (μPCT) and a gas chromatographic separation column (μSC) for use in a micro gas chromatograph (μGC) using one photomask is described. By electroless gold plating, a high-surface-area gold layer was deposited on the surface of channels inside the μPCT and μSC. For this process, (3-aminopropyl) trimethoxysilane (APTMS) was used as a promoter for attaching gold nanoparticles on a silicon substrate to create a seed layer. For this purpose, a gold sodium sulfite solution was used as reagent for depositing gold to form heating structures. The microchannels of the μPCT and μSC were coated with the adsorbent and stationary phase, Tenax-TA and polydimethylsiloxane (DB-1), respectively. μPCTs were heated at temperatures greater than 280 °C under an applied electrical power of 24 W and a heating rate of 75 °C s-1. Repeatable thermal heating responses for μPCTs were achieved; good linearity (R 2  >  0.9997) was attained at three heating rates for the temperature programme for the μSC (0.2, 0.5 and 1 °C s-1). The volatile organic compounds (VOCs) toluene and m-xylene were concentrated over the μPCT by rapid thermal desorption (peak width of half height (PWHH)  <1.5 s) preconcentration factors for both VOCs are  >7900. The VOCs acetone, benzene, toluene, m-xylene and 1,3,5-trimethylbenzene were also separated on the μSC as evidenced by their different retention times (47-184 s).

  10. Recent highlights in electro-driven separations- selected applications of alkylthiol gold nanoparticles in capillary electrophoresis and capillary electro-chromatography.

    PubMed

    Guihen, Elizabeth

    2017-09-01

    To date, alkylthiol gold nanoparticles (AuNPs) have been widely used in electro-chromatographic separation techniques as a viable alternative to traditional stationary phases. This is mainly due to their stability, chemical inertness, ease of functionality, increased phase ratio, ability to form self-assembled monolayers. They also yield versatile stationary phases with highly specific targeted functionalities. At the nanoscale region, the chemical and physical properties of a molecule display different attributes to that of the parent molecules or material, hence these features can be harnessed in electro-driven chromatographic separations. Application areas illustrating the use of AuNPs in separation science continue to grow and expand to cover many different kinds of analysis. The last decade has witnessed a successful trend in miniaturisation of chemical separation systems toward the micro and nanoscale ranges. Nanoparticle-based stationary phases fit well with performing chemical separations on microfluidic and capillary platforms. In this review the theory of the use of alkylthiol gold nanoparticles in electro-chromatographic driven separation methods will be discussed. This will be followed by details of recent and selected applications showing alkylthiol gold nanoparticles in capillary electrophoretic and open-tubular electro-chromatographic separations. This review will focus solely on alkylthiol based gold nanoparticles, therefore other kinds of chemical moieties bonded to gold nanoparticles are outside the scope of this review. Finally the future outlook of this exciting technology will be outlined in some detail in the final section. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blay, J.A.

    The problem of the determination of micro-amounts of uranium in aqueous and organic phases in liquid-liquid extraction processes, original ones, and extraction residues was solved by a chromatographic separation of the uranium by means of columns of activated cellulose and further spectrophotometric evaluation using the thiocyanate complex in aqueous medium. The usable range is 5 to 200 mu g.

  12. On-line coupling of supercritical fluid extraction and chromatographic techniques.

    PubMed

    Sánchez-Camargo, Andrea Del Pilar; Parada-Alfonso, Fabián; Ibáñez, Elena; Cifuentes, Alejandro

    2017-01-01

    This review summarizes and discusses recent advances and applications of on-line supercritical fluid extraction coupled to liquid chromatography, gas chromatography, and supercritical fluid chromatographic techniques. Supercritical fluids, due to their exceptional physical properties, provide unique opportunities not only during the extraction step but also in the separation process. Although supercritical fluid extraction is especially suitable for recovery of non-polar organic compounds, this technique can also be successfully applied to the extraction of polar analytes by the aid of modifiers. Supercritical fluid extraction process can be performed following "off-line" or "on-line" approaches and their main features are contrasted herein. Besides, the parameters affecting the supercritical fluid extraction process are explained and a "decision tree" is for the first time presented in this review work as a guide tool for method development. The general principles (instrumental and methodological) of the different on-line couplings of supercritical fluid extraction with chromatographic techniques are described. Advantages and shortcomings of supercritical fluid extraction as hyphenated technique are discussed. Besides, an update of the most recent applications (from 2005 up to now) of the mentioned couplings is also presented in this review. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Adsorption behavior of plasmid DNA onto perfusion chromatographic matrix.

    PubMed

    Limonta, Miladys; Zumalacárregui, Lourdes; Soler, Dayana

    2012-05-01

    Anion exchange chromatography is the most popular chromatographic method for plasmid separation. POROS RI 50 is a perfusion chromatographic support which is a reversed phase matrix and is an alternative to conventional ones due to its mass transfer properties. The adsorption and elution of the pIDKE2 plasmid onto reversed phase POROS R1 50 was studied. Langmuir isotherm model was adjusted in order to get the maximum adsorption capacity and the dissociation constant for POROS R1 50-plasmid DNA (pDNA) system. Breakthrough curves were obtained for volumetric flows between 0.69-3.33 mL/min, given dynamic capacity up to 2.3 times higher than those reported for ionic exchange matrix used during the purification process of plasmids with similar size to that of pIDKE2. The efficiency was less than 45% for the flow conditions and initial concentration studied, which means that the support will not be operated under saturation circumstances.

  14. Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry

    NASA Technical Reports Server (NTRS)

    Ricci, M. P.; Merritt, D. A.; Freeman, K. H.; Hayes, J. M.

    1994-01-01

    Methods are described for continuous monitoring of signals required for precise analyses of 13C, 18O, and 15N in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.

  15. High-pressure liquid chromatography of aromatic amines

    NASA Technical Reports Server (NTRS)

    Young, P. R.

    1979-01-01

    Analysis made on commercially available liquid chromatograph demonstrates high-pressure liquid chromatographic conditions for separation of approximately 50 aromatic amines ranging from simple aniline derivatives to complex multiring di- and tri-amines.

  16. Facile room-temperature solution-phase synthesis of a spherical covalent organic framework for high-resolution chromatographic separation.

    PubMed

    Yang, Cheng-Xiong; Liu, Chang; Cao, Yi-Meng; Yan, Xiu-Ping

    2015-08-07

    A simple and facile room-temperature solution-phase synthesis was developed to fabricate a spherical covalent organic framework with large surface area, good solvent stability and high thermostability for high-resolution chromatographic separation of diverse important industrial analytes including alkanes, cyclohexane and benzene, α-pinene and β-pinene, and alcohols with high column efficiency and good precision.

  17. Separation of Protactinium Employing Sulfur-Based Extraction Chromatographic Resins.

    PubMed

    Mastren, Tara; Stein, Benjamin W; Parker, T Gannon; Radchenko, Valery; Copping, Roy; Owens, Allison; Wyant, Lance E; Brugh, Mark; Kozimor, Stosh A; Nortier, F Meiring; Birnbaum, Eva R; John, Kevin D; Fassbender, Michael E

    2018-06-05

    Protactinium-230 ( t 1/2 = 17.4 d) is the parent isotope of 230 U ( t 1/2 = 20.8 d), a radionuclide of interest for targeted alpha therapy (TAT). Column chromatographic methods have been developed to separate no-carrier-added 230 Pa from proton irradiated thorium targets and accompanying fission products. Results reported within demonstrate the use of novel sulfur bearing chromatographic extraction resins for the selective separation of protactinium. The recovery yield of 230 Pa was 93 ± 4% employing a R 3 P═S type commercially available resin and 88 ± 4% employing a DGTA (diglycothioamide) containing custom synthesized extraction chromatographic resin. The radiochemical purity of the recovered 230 Pa was measured via high purity germanium γ-ray spectroscopy to be >99.5% with the remaining radioactive contaminant being 95 Nb due to its similar chemistry to protactinium. Measured equilibrium distribution coefficients for protactinium, thorium, uranium, niobium, radium, and actinium on both the R 3 P═S type and the DGTA resin in hydrochloric acid media are reported, to the best of our knowledge, for the first time.

  18. Separation of Protactinium Employing Sulfur-Based Extraction Chromatographic Resins

    DOE PAGES

    Mastren, Tara; Stein, Benjamin W.; Parker, T. Gannon; ...

    2018-05-14

    Protactinium-230 (t 1/2 = 17.4 d) is the parent isotope of 230U (t 1/2 = 20.8 d), a radionuclide of interest for targeted alpha therapy (TAT). Column chromatographic methods have been developed to separate no-carrier-added 230Pa from proton irradiated thorium targets and accompanying fission products. Results reported within this paper demonstrate the use of novel sulfur bearing chromatographic extraction resins for the selective separation of protactinium. The recovery yield of 230Pa was 93 ± 4% employing a R 3P=S type commercially available resin and 88 ± 4% employing a DGTA (diglycothioamide) containing custom synthesized extraction chromatographic resin. The radiochemical puritymore » of the recovered 230Pa was measured via high purity germanium γ-ray spectroscopy to be >99.5% with the remaining radioactive contaminant being 95Nb due to its similar chemistry to protactinium. Finally, measured equilibrium distribution coefficients for protactinium, thorium, uranium, niobium, radium, and actinium on both the R 3P=S type and the DGTA resin in hydrochloric acid media are reported, to the best of our knowledge, for the first time.« less

  19. Separation of Protactinium Employing Sulfur-Based Extraction Chromatographic Resins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mastren, Tara; Stein, Benjamin W.; Parker, T. Gannon

    Protactinium-230 (t 1/2 = 17.4 d) is the parent isotope of 230U (t 1/2 = 20.8 d), a radionuclide of interest for targeted alpha therapy (TAT). Column chromatographic methods have been developed to separate no-carrier-added 230Pa from proton irradiated thorium targets and accompanying fission products. Results reported within this paper demonstrate the use of novel sulfur bearing chromatographic extraction resins for the selective separation of protactinium. The recovery yield of 230Pa was 93 ± 4% employing a R 3P=S type commercially available resin and 88 ± 4% employing a DGTA (diglycothioamide) containing custom synthesized extraction chromatographic resin. The radiochemical puritymore » of the recovered 230Pa was measured via high purity germanium γ-ray spectroscopy to be >99.5% with the remaining radioactive contaminant being 95Nb due to its similar chemistry to protactinium. Finally, measured equilibrium distribution coefficients for protactinium, thorium, uranium, niobium, radium, and actinium on both the R 3P=S type and the DGTA resin in hydrochloric acid media are reported, to the best of our knowledge, for the first time.« less

  20. A multimodal histamine ligand for chromatographic purification of plasmid DNA.

    PubMed

    Černigoj, Urh; Vidic, Urška; Barut, Miloš; Podgornik, Aleš; Peterka, Matjaž; Štrancar, Aleš

    2013-03-15

    To exploit different chromatographic modes for efficient plasmid DNA (pDNA) purification a novel monolithic chromatographic support bearing multimodal histamine (HISA) groups was developed and characterized. Electrostatic charge of HISA groups depends on the pH of the mobile phase, being neutral above pH 7 and becoming positively charged below. As a consequence, HISA groups exhibit predominantly ion-exchange character at low pH values, which decreases with titration of the HISA groups resulting in increased hydrophobicity. This feature enabled separation of supercoiled (sc) pDNA from other plasmid isoforms (and other process related impurities) by adjusting salt or pH gradient. The dynamic binding capacity (DBC) for a 5.1kbp large plasmid at pH 5 was 4.0 mg/ml under low salt binding conditions, remaining relatively high (3.0 mg/ml) even in the presence of 1.0 M NaCl due to the multimodal nature of HISA ligand. Only slightly lower DBC (2.7 mg/ml) was determined under preferentially hydrophobic conditions in 3.0 M (NH(4))(2)SO(4), pH 7.4. Open circular and sc pDNA isoforms were baseline separated in descending (NH(4))(2)SO(4) gradient. Furthermore, an efficient plasmid DNA separation was possible both on analytical as well as on preparative scale by applying the descending pH gradient at a constant concentration (above 3.0 M) of (NH(4))(2)SO(4). Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Gas chromatograph-mass spectrometer (GC/MS) system for quantitative analysis of reactive chemical compounds

    DOEpatents

    Grindstaff, Quirinus G.

    1992-01-01

    Described is a new gas chromatograph-mass spectrometer (GC/MS) system and method for quantitative analysis of reactive chemical compounds. All components of such a GC/MS system external to the oven of the gas chromatograph are programmably temperature controlled to operate at a volatilization temperature specific to the compound(s) sought to be separated and measured.

  2. Evaluation of Comprehensive 2-D Gas Chromatography-Time-Of-Flight Mass Spectrometry for 209 Chlorinated Biphenyl Congeners in Two Chromatographic Runs

    EPA Science Inventory

    This research evaluates a recently developed comprehensive 2-D GC coupled with a time-of-flight (TOF) mass spectrometer for the potential separation of 209 PCB congeners, using a sequence of 1-D and 2-D chromatographic modes. In two consecutive chromatographic runs, using a 40 m,...

  3. High-resolution hydrodynamic chromatographic separation of large DNA using narrow, bare open capillaries: a rapid and economical alternative technology to pulsed-field gel electrophoresis?

    PubMed

    Liu, Lei; Veerappan, Vijaykumar; Pu, Qiaosheng; Cheng, Chang; Wang, Xiayan; Lu, Liping; Allen, Randy D; Guo, Guangsheng

    2014-01-07

    A high-resolution, rapid, and economical hydrodynamic chromatographic (HDC) method for large DNA separations in free solution was developed using narrow (5 μm diameter), bare open capillaries. Size-based separation was achieved in a chromatographic format with larger DNA molecules being eluting faster than smaller ones. Lambda DNA Mono Cut Mix was baseline-separated with the percentage resolutions generally less than 9.0% for all DNA fragments (1.5 to 48.5 kbp) tested in this work. High efficiencies were achieved for large DNA from this chromatographic technique, and the number of theoretical plates reached 3.6 × 10(5) plates for the longest (48.5 kbp) and 3.7 × 10(5) plates for the shortest (1.5 kbp) fragments. HDC parameters and performances were also discussed. The method was further applied for fractionating large DNA fragments from real-world samples (SacII digested Arabidopsis plant bacterial artificial chromosome (BAC) DNA and PmeI digested Rice BAC DNA) to demonstrate its feasibility for BAC DNA finger printing. Rapid separation of PmeI digested Rice BAC DNA covering from 0.44 to 119.041 kbp was achieved in less than 26 min. All DNA fragments of these samples were baseline separated in narrow bare open capillaries, while the smallest fragment (0.44 kbp) was missing in pulsed-field gel electrophoresis (PFGE) separation mode. It is demonstrated that narrow bare open capillary chromatography can realize a rapid separation for a wide size range of DNA mixtures that contain both small and large DNA fragments in a single run.

  4. Separation of the stereoisomers of the main metabolite of a non-steroidal anti-inflammatory drug, flobufen, by chiral high-performance liquid chromatography.

    PubMed

    Wsól, V; Fell, A F; Kvasnicková, E; Hais, I M

    1997-02-07

    The major metabolite of a novel non-steroidal anti-inflammatory drug, DL-4-(2',4'-difluorobiphenyl-4-yl)-2-oxo-2-methylbutanoic acid (flobufen, I), namely 4-(2',4'-difluorobiphenyl-4-yl)-2-methyl-gamma-butyrolactone (4-dihydroflobufen lactone, III), has four stereoisomers consisting of two racemic pairs of enantiomers. Of three chiral stationary phases tested, Cyclobond I beta-RSP (Astec) (beta-cylodextrin derivatized with R,S-hydroxypropyl) was best able to separate the (+2)(--) racemate, with a liquid phase containing acetonitrile as modifier and triethylamine acetate as buffer. Using the Box-Wilson Central Composite Design for three factors, an optimum combination of pH and concentrations of the modifier and buffer was eventually obtained. A chromatographic response function based on a combination of the Kaiser peak separation function, Pi, and retention time of the second eluting enantiomer, tRL, served as a response criterion for the process of optimization. The optimum conditions developed for the (+2)(--) racemate were also found to be suitable for separating the (+-)(-+) racemate, for which earlier studies had shown the separation to be more facile. Separation of the four stereoisomers of III, for which the chiral chromatographic system optimized in this study is proposed as the second stage, is targeted at a biochemical study of the stereoisomeric metabolism of I.

  5. Chromatographic Separations Using Solid-Phase Extraction Cartridges: Separation of Wine Phenolics

    NASA Astrophysics Data System (ADS)

    Brenneman, Charles A.; Ebeler, Susan E.

    1999-12-01

    We describe a simple laboratory experiment that demonstrates the principles of chromatographic separation using solid-phase extraction columns and red wine. By adjusting pH and mobile phase composition, the wine is separated into three fractions of differing polarity. The content of each fraction can be monitored by UV-vis spectroscopy. When the experiment is combined with experiments involving HPLC or GC separations, students gain a greater appreciation for and understanding of the highly automated instrumental systems currently available. In addition, they learn about the chemistry of polyphenolic compounds, which are present in many foods and beverages and which are receiving much attention for their potentially beneficial health effects.

  6. Process for the separation and purification of yttrium-90 for medical applications

    DOEpatents

    Horwitz, P.E.; Dietz, M.L.

    1994-11-29

    An extraction chromatographic method for the preparation of [sup 90]Y of high chemical and radiochemical purity is disclosed. After an initial purification of a [sup 90]Sr stock solution and a suitable period of [sup 90]Y ingrowth, the solution is passed through a series of strontium-selective chromatographic columns, each of which lowers the [sup 90]Sr content of the mixture by a factor of about 10[sup 3]. The [sup 90]Y remaining is freed from any residual [sup 90]Sr, from its [sup 90]Zr daughter, and from any remaining impurities by passing the sample through a final column designed to selectively retain yttrium. 5 figures.

  7. A process for the separation and purification of yttrium-90 for medical applications

    DOEpatents

    Horwitz, P.E.; Dietz, M.L.

    1993-01-01

    An extraction chromatographic method for the preparation of {sup 90}Y of high chemical and radiochemical purity is disclosed. After an initial purification of a {sup 90}Sr stock solution and a suitable period of {sup 90}Y ingrowth, the solution is passed through a series of strontium-selective chromatographic columns, each of which lowers the {sup 90}Sr content of the mixture by a factor of about 10{sup 3}. The {sup 90}Y remaining is freed from any residual {sup 90}Sr, from its {sup 90}Zr daughter, and from any remaining impurities by passing the sample through a final column designed to selectively retain yttrium.

  8. Process for the separation and purification of yttrium-90 for medical applications

    DOEpatents

    Horwitz, Philip E.; Dietz, Mark L.

    1994-01-01

    An extraction chromatographic method for the preparation of .sup.90 Y of high chemical and radiochemical purity is disclosed. After an initial purification of a .sup.90 Sr stock solution and a suitable period of .sup.90 Y ingrowth, the solution is passed through a series of strontium-selective chromatographic columns, each of which lowers the .sup.90 Sr content of the mixture by a factor of about 10.sup.3. The .sup.90 Y remaining is freed from any residual .sup.90 Sr, from its .sup.90 Zr daughter, and from any remaining impurities by passing the sample through a final column designed to selectively retain yttrium.

  9. Mathematical analysis of frontal affinity chromatography in particle and membrane configurations.

    PubMed

    Tejeda-Mansir, A; Montesinos, R M; Guzmán, R

    2001-10-30

    The scaleup and optimization of large-scale affinity-chromatographic operations in the recovery, separation and purification of biochemical components is of major industrial importance. The development of mathematical models to describe affinity-chromatographic processes, and the use of these models in computer programs to predict column performance is an engineering approach that can help to attain these bioprocess engineering tasks successfully. Most affinity-chromatographic separations are operated in the frontal mode, using fixed-bed columns. Purely diffusive and perfusion particles and membrane-based affinity chromatography are among the main commercially available technologies for these separations. For a particular application, a basic understanding of the main similarities and differences between particle and membrane frontal affinity chromatography and how these characteristics are reflected in the transport models is of fundamental relevance. This review presents the basic theoretical considerations used in the development of particle and membrane affinity chromatography models that can be applied in the design and operation of large-scale affinity separations in fixed-bed columns. A transport model for column affinity chromatography that considers column dispersion, particle internal convection, external film resistance, finite kinetic rate, plus macropore and micropore resistances is analyzed as a framework for exploring further the mathematical analysis. Such models provide a general realistic description of almost all practical systems. Specific mathematical models that take into account geometric considerations and transport effects have been developed for both particle and membrane affinity chromatography systems. Some of the most common simplified models, based on linear driving-force (LDF) and equilibrium assumptions, are emphasized. Analytical solutions of the corresponding simplified dimensionless affinity models are presented. Particular methods for estimating the parameters that characterize the mass-transfer and adsorption mechanisms in affinity systems are described.

  10. [A method for the analysis of overlapped peaks in the high performance liquid chromatogram based on spectrum analysis].

    PubMed

    Liu, Bao; Fan, Xiaoming; Huo, Shengnan; Zhou, Lili; Wang, Jun; Zhang, Hui; Hu, Mei; Zhu, Jianhua

    2011-12-01

    A method was established to analyse the overlapped chromatographic peaks based on the chromatographic-spectra data detected by the diode-array ultraviolet detector. In the method, the three-dimensional data were de-noised and normalized firstly; secondly the differences and clustering analysis of the spectra at different time points were calculated; then the purity of the whole chromatographic peak were analysed and the region were sought out in which the spectra of different time points were stable. The feature spectra were extracted from the spectrum-stable region as the basic foundation. The nonnegative least-square method was chosen to separate the overlapped peaks and get the flow curve which was based on the feature spectrum. The three-dimensional divided chromatographic-spectrum peak could be gained by the matrix operations of the feature spectra with the flow curve. The results displayed that this method could separate the overlapped peaks.

  11. SEPARATION OF PLUTONIUM FROM URANIUM AND FISSION PRODUCTS

    DOEpatents

    Boyd, G.E.; Adamson, A.W.; Schubert, J.; Russell, E.R.

    1958-10-01

    A chromatographic adsorption process is presented for the separation of plutonium from other fission products formed by the irradiation of uranium. The plutonium and the lighter element fission products are adsorbed on a sulfonated phenol-formaldehyde resin bed from a nitric acid solution containing the dissolved uranium. Successive washes of sulfuric, phosphoric, and nitric acids remove the bulk of the fission products, then an eluate of dilute phosphoric and nitric acids removes the remaining plutonium and fission products. The plutonium is selectively removed by passing this solution through zirconium phosphate, from which the plutonium is dissolved with nitric acid. This process provides a convenient and efficient means for isolating plutonium.

  12. Predicting the chromatographic retention of polymers: poly(methyl methacrylate)s and polyacryate blends.

    PubMed

    Bashir, Mubasher A; Radke, Wolfgang

    2007-09-07

    The suitability of a retention model especially designed for polymers is investigated to describe and predict the chromatographic retention behavior of poly(methyl methacrylate)s as a function of mobile phase composition and gradient steepness. It is found that three simple yet rationally chosen chromatographic experiments suffice to extract the analyte specific model parameters necessary to calculate the retention volumes. This allows predicting accurate retention volumes based on a minimum number of initial experiments. Therefore, methods for polymer separations can be developed in relatively short time. The suitability of the virtual chromatography approach to predict the separation of polymer blend is demonstrated for the first time using a blend of different polyacrylates.

  13. Development of a purification procedure for the isolation of nucleosides from urine prior to mass spectrometric analysis.

    PubMed

    Dudley, E; El-Shakawi, S; Games, D E; Newton, R P

    2000-03-01

    A chromatographic separation of nucleosides from urine has been developed in order to facilitate their mass spectrometric analysis for clinical diagnosis. A number of chromatographic resins were studied in order to develop an effective and efficient purification procedure. The optimized sequential protocol comprises a centrifugation, acidification and neutralization step, followed by application of an affinity chromatographic column and finally further separation on an acidic cation exchange column and a basic anion exchanger. This scheme shows effective clean-up of a standard radiolabelled nucleoside with a recovery of 92.5%, and recovery of nucleosides added to urine samples before extraction showed recoveries of 72-82%.

  14. Continuous downstream processing for high value biological products: A Review.

    PubMed

    Zydney, Andrew L

    2016-03-01

    There is growing interest in the possibility of developing truly continuous processes for the large-scale production of high value biological products. Continuous processing has the potential to provide significant reductions in cost and facility size while improving product quality and facilitating the design of flexible multi-product manufacturing facilities. This paper reviews the current state-of-the-art in separations technology suitable for continuous downstream bioprocessing, focusing on unit operations that would be most appropriate for the production of secreted proteins like monoclonal antibodies. This includes cell separation/recycle from the perfusion bioreactor, initial product recovery (capture), product purification (polishing), and formulation. Of particular importance are the available options, and alternatives, for continuous chromatographic separations. Although there are still significant challenges in developing integrated continuous bioprocesses, recent technological advances have provided process developers with a number of attractive options for development of truly continuous bioprocessing operations. © 2015 Wiley Periodicals, Inc.

  15. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    PubMed

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.

  16. Chiral ionic liquids in chromatographic and electrophoretic separations.

    PubMed

    Kapnissi-Christodoulou, Constantina P; Stavrou, Ioannis J; Mavroudi, Maria C

    2014-10-10

    This report provides an overview of the application of chiral ionic liquids (CILs) in separation technology, and particularly in capillary electrophoresis and both gas and liquid chromatography. There is a large number of CILs that have been synthesized and designed as chiral agents. However, only a few have successfully been applied in separation technology. Even though this application of CILs is still in its early stages, the scientific interest is increasing dramatically. This article is focused on the use of CILs as chiral selectors, background electrolyte additives, chiral ligands and chiral stationary phases in electrophoretic and chromatographic techniques. Different examples of CILs, which contain either a chiral cation, a chiral anion or both, are presented in this review article, and their major advantages along with their potential applications in chiral electrophoretic and chromatographic recognition are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  18. Sugar, acid and furfural quantification in a sulphite pulp mill: Feedstock, product and hydrolysate analysis by HPLC/RID.

    PubMed

    Llano, Tamara; Quijorna, Natalia; Andrés, Ana; Coz, Alberto

    2017-09-01

    Waste from pulp and paper mills consist of sugar-rich fractions comprising hemicellulose derivatives and cellulose by-products. A complete characterisation of the waste streams is necessary to study the possibilities of an existing mill. In this work, four chromatographic methods have been developed to obtain the most suitable chromatographic method conditions for measuring woody feedstocks, lignocellulosic hydrolysates and cellulose pulp in sulphite pulping processes. The analysis of major and minor monosaccharides, aliphatic carboxylic acids and furfurals has been optimised. An important drawback of the spent liquors generated after sulphite pulping is their acidic nature, high viscosity and adhesive properties that interfere in the column lifetime. This work recommends both a CHO-782Pb column for the sugar analysis and an SH-1011 resin-based cross-linked gel column to separate low-molecular-weight chain acids, alcohols and furfurals. Such columns resulted in a good separation with long lifetime, wide pH operating range and low fouling issues.

  19. Separation and characterization of antioxidants from Spirulina platensis microalga combining pressurized liquid extraction, TLC, and HPLC-DAD.

    PubMed

    Jaime, Laura; Mendiola, José A; Herrero, Miguel; Soler-Rivas, Cristina; Santoyo, Susana; Señorans, F Javier; Cifuentes, Alejandro; Ibáñez, Elena

    2005-11-01

    A new procedure has been developed to separate and characterize antioxidant compounds from Spirulina platensis microalga based on the combination of pressurized liquid extraction (PLE) and different chromatographic procedures, such as TLC, at preparative scale, and HPLC with a diode array detector (DAD). Different solvents were tested for PLE extraction of antioxidants from S. platensis microalga. An optimized PLE process using ethanol (generally recognized as safe, GRAS) as extraction solvent has been obtained that provides natural extracts with high yields and good antioxidant properties. TLC analysis of this ethanolic extract obtained at 115 degrees C for 15 min was carried out and the silica layer was stained with a DPPH (diphenyl-pycril-hydrazyl) radical solution to determine the antioxidant activity of different chromatographic bands. Next, these colored bands were collected for their subsequent analysis by HPLC-DAD, revealing that the compounds with the most important antioxidant activity present in Spirulina extracts were carotenoids, as well as phenolic compounds and degradation products of chlorophylls.

  20. Chemometric Strategies for Peak Detection and Profiling from Multidimensional Chromatography.

    PubMed

    Navarro-Reig, Meritxell; Bedia, Carmen; Tauler, Romà; Jaumot, Joaquim

    2018-04-03

    The increasing complexity of omics research has encouraged the development of new instrumental technologies able to deal with these challenging samples. In this way, the rise of multidimensional separations should be highlighted due to the massive amounts of information that provide with an enhanced analyte determination. Both proteomics and metabolomics benefit from this higher separation capacity achieved when different chromatographic dimensions are combined, either in LC or GC. However, this vast quantity of experimental information requires the application of chemometric data analysis strategies to retrieve this hidden knowledge, especially in the case of nontargeted studies. In this work, the most common chemometric tools and approaches for the analysis of this multidimensional chromatographic data are reviewed. First, different options for data preprocessing and enhancement of the instrumental signal are introduced. Next, the most used chemometric methods for the detection of chromatographic peaks and the resolution of chromatographic and spectral contributions (profiling) are presented. The description of these data analysis approaches is complemented with enlightening examples from omics fields that demonstrate the exceptional potential of the combination of multidimensional separation techniques and chemometric tools of data analysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Detection of non-protein amino acids in the presence of protein amino acids. II.

    NASA Technical Reports Server (NTRS)

    Shapshak, P.; Okaji, M.

    1972-01-01

    Studies conducted with the JEOL 5AH amino acid analyzer are described. This instrument makes possible the programming of the chromatographic process. Data are presented showing the separations of seventeen non-protein amino acids in the presence of eighteen protein amino acids. It is pointed out that distinct separations could be obtained in the case of a number of chemically similar compounds, such as ornithine and lysine, N-amidino alanine and arginine, and iminodiacetic acid and S-carboxymethyl cysteine and aspartic acid.

  2. Separation of metal ions from aqueous solutions

    DOEpatents

    Almon, Amy C.

    1994-01-01

    A process and apparatus for quantitatively and selectively separating metal ions from mixtures thereof in aqueous solution. The apparatus includes, in combination, a horizontal electrochemical flow cell containing flow bulk electrolyte solution and an aqueous, metal ion-containing solution, the cell containing a metal mesh working electrode, a counter electrode positioned downstream from the working electrode, an independent variable power supply/potentiostat positioned outside of the flow cell and connected to the electrodes, and optionally a detector such as a chromatographic detector, positioned outside the flow cell. This apparatus and its operation has significant application where trace amounts of metal ions are to be separated.

  3. Incorporation of metal-organic framework HKUST-1 into porous polymer monolithic capillary columns to enhance the chromatographic separation of small molecules.

    PubMed

    Yang, Shengchao; Ye, Fanggui; Lv, Qinghui; Zhang, Cong; Shen, Shufen; Zhao, Shulin

    2014-09-19

    Metal-organic framework (MOF) HKUST-1 nanoparticles have been incorporated into poly(glycidyl methacrylate-co-ethylene dimethacrylate) (HKUST-1-poly(GMA-co-EDMA)) monoliths to afford stationary phases with enhanced chromatographic performance of small molecules in the reversed phase capillary liquid chromatography. The effect of HKUST-1 nanoparticles in the polymerization mixture on the performance of the monolithic column was explored in detail. While the bare poly(GMA-co-EDMA) monolith exhibited poor resolution (Rs<1.0) and low efficiency (800-16,300plates/m), addition of a small amount of HKUST-1 nanoparticles to the polymerization mixture provide high increased resolution (Rs≥1.3) and high efficiency ranged from 16,300 to 44,300plates/m. Chromatographic performance of HKUST-1-poly(GMA-co-EDMA) monolith was demonstrated by separation of various analytes including polycyclic aromatic hydrocarbons, ethylbenzene and styrene, phenols and aromatic acids using a binary polar mobile phase (CH3CN/H2O). The HKUST-1-poly(GMA-co-EDMA) monolith displayed enhanced hydrophobic and π-π interaction characteristics in the reversed phase separation of test analytes compared to the bare poly(GMA-co-EDMA) monolith. The experiment results showed that HKUST-1-poly(GMA-co-EDMA) monoliths are an alternative to enhance the chromatographic separation of small molecules. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Preparation of porous hollow silica spheres via a layer-by-layer process and the chromatographic performance

    NASA Astrophysics Data System (ADS)

    Wei, Xiaobing; Gong, Cairong; Chen, Xujuan; Fan, Guoliang; Xu, Xinhua

    2017-03-01

    Hollow silica spheres possessing excellent mechanical properties were successfully prepared through a layer-by-layer process using uniform polystyrene (PS) latex fabricated by dispersion polymerization as template. The formation of hollow SiO2 micro-spheres, structures and properties were observed in detail by zeta potential, SEM, TEM, FTIR, TGA and nitrogen sorption porosimetry. The results indicated that the hollow spheres were uniform with particle diameter of 1.6 μm and shell thickness of 150 nm. The surface area was 511 m2/g and the pore diameter was 8.36 nm. A new stationary phase for HPLC was obtained by using C18-derivatized hollow SiO2 micro-spheres as packing materials and the chromatographic properties were evaluated for the separation of some regular small molecules. The packed column showed low column pressure, high values of efficiency (up to about 43 000 plates/m) and appropriate asymmetry factors.

  5. Unified superresolution experiments and stochastic theory provide mechanistic insight into protein ion-exchange adsorptive separations

    PubMed Central

    Kisley, Lydia; Chen, Jixin; Mansur, Andrea P.; Shuang, Bo; Kourentzi, Katerina; Poongavanam, Mohan-Vivekanandan; Chen, Wen-Hsiang; Dhamane, Sagar; Willson, Richard C.; Landes, Christy F.

    2014-01-01

    Chromatographic protein separations, immunoassays, and biosensing all typically involve the adsorption of proteins to surfaces decorated with charged, hydrophobic, or affinity ligands. Despite increasingly widespread use throughout the pharmaceutical industry, mechanistic detail about the interactions of proteins with individual chromatographic adsorbent sites is available only via inference from ensemble measurements such as binding isotherms, calorimetry, and chromatography. In this work, we present the direct superresolution mapping and kinetic characterization of functional sites on ion-exchange ligands based on agarose, a support matrix routinely used in protein chromatography. By quantifying the interactions of single proteins with individual charged ligands, we demonstrate that clusters of charges are necessary to create detectable adsorption sites and that even chemically identical ligands create adsorption sites of varying kinetic properties that depend on steric availability at the interface. Additionally, we relate experimental results to the stochastic theory of chromatography. Simulated elution profiles calculated from the molecular-scale data suggest that, if it were possible to engineer uniform optimal interactions into ion-exchange systems, separation efficiencies could be improved by as much as a factor of five by deliberately exploiting clustered interactions that currently dominate the ion-exchange process only accidentally. PMID:24459184

  6. Unified superresolution experiments and stochastic theory provide mechanistic insight into protein ion-exchange adsorptive separations.

    PubMed

    Kisley, Lydia; Chen, Jixin; Mansur, Andrea P; Shuang, Bo; Kourentzi, Katerina; Poongavanam, Mohan-Vivekanandan; Chen, Wen-Hsiang; Dhamane, Sagar; Willson, Richard C; Landes, Christy F

    2014-02-11

    Chromatographic protein separations, immunoassays, and biosensing all typically involve the adsorption of proteins to surfaces decorated with charged, hydrophobic, or affinity ligands. Despite increasingly widespread use throughout the pharmaceutical industry, mechanistic detail about the interactions of proteins with individual chromatographic adsorbent sites is available only via inference from ensemble measurements such as binding isotherms, calorimetry, and chromatography. In this work, we present the direct superresolution mapping and kinetic characterization of functional sites on ion-exchange ligands based on agarose, a support matrix routinely used in protein chromatography. By quantifying the interactions of single proteins with individual charged ligands, we demonstrate that clusters of charges are necessary to create detectable adsorption sites and that even chemically identical ligands create adsorption sites of varying kinetic properties that depend on steric availability at the interface. Additionally, we relate experimental results to the stochastic theory of chromatography. Simulated elution profiles calculated from the molecular-scale data suggest that, if it were possible to engineer uniform optimal interactions into ion-exchange systems, separation efficiencies could be improved by as much as a factor of five by deliberately exploiting clustered interactions that currently dominate the ion-exchange process only accidentally.

  7. A Gas Chromatographic Continuous Emissions Monitoring System for the Determination of VOCs and HAPs.

    PubMed

    Coleman, William M; Gordon, Bert M

    1996-01-01

    This article describes a new gas chromatography-based emissions monitoring system for measuring volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). The system is composed of a dual-column gas chromatograph equipped with thermal conductivity detectors, in which separation is optimized for fast chromatography. The system has the necessary valving for stream selection, which allows automatic calibration of the system at predetermined times and successive measurement of individual VOCs before and after a control device. Nine different VOCs (two of which are HAPs), plus methane (CH4) and carbon dioxide (CO2) are separated and quantified every two minutes. The accuracy and precision of this system has been demonstrated to be greater than 95%. The system employs a mass flow measurement device and also calculates and displays processed emission data, such as control device efficiency and total weight emitted during given time periods. Two such systems have been operational for one year in two separate gravure printing facilities; minimal upkeep is required, about one hour per month. One of these systems, used before and after a carbon adsorber, has been approved by the pertinent local permitting authority.

  8. DEVELOPMENT AND VALIDATION OF AN ION CHROMATOGRAPHIC METHOD FOR DETERMINING PERCHLORATE IN FERTILIZERS

    EPA Science Inventory

    A method has been developed for the determination of perchlorate in fertilizers. Materials are leached with deionized water to dissolve any soluble perchlorate compounds. Ion chromatographic separation is followed by suppressed conductivity for detection. Perchlorate is retained ...

  9. Tunable thick porous silica coating fabricated by multilayer-by-multilayer bonding of silica nanoparticles for open-tubular capillary chromatographic separation.

    PubMed

    Qu, Qishu; Liu, Yuanyuan; Shi, Wenjun; Yan, Chao; Tang, Xiaoqing

    2015-06-19

    A simple coating procedure employing a multilayer-by-multilayer process to modify the inner surface of bare fused-silica capillaries with silica nanoparticles was established. The silica nanoparticles were adsorbed onto the capillary wall via a strong electrostatic interaction between amino functional groups and silica particles. The thickness of the coating could be tuned from 130 to 600 nm by increasing the coating cycles from one to three. Both the retention factor and the resolution were greatly increased with increasing coating cycles. The loading capacity determined by naphthalene in the column with three coating cycles is 152.1 pmol. The effects of buffer concentration and pH value on the stability of the coating were evaluated. The retention reproducibility of the separation of toluene was 0.8, 1.2, 2.3, and 4.5%, respectively, for run-to-run, day-to-day, column-to-column, and batch-to-batch, respectively. The chromatographic performance of these columns was evaluated by both capillary liquid chromatography and open-tubular capillary electrochromatography (OT-CEC). Separation of aromatic hydrocarbons in the column with three coating cycles provided high theoretical plate numbers (up to 269,280 plates m(-1) for toluene) and short separation time (<15 min) by using OT-CEC mode. The method was also used to separate egg white proteins. Both acidic and basic proteins as well as four glycoisoforms were separated in a single run. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Fingerprint of Hedyotis diffusa Willd. by HPLC-MS.

    PubMed

    Yang, Ting; Yang, Yi-Hua; Yang, Ju-Yun; Chen, Ben-Mei; Duan, Ju-Ping; Yu, Shu-Yi; Ouyang, Hong-Tao; Cheng, Jun-Ping; Chen, Yu-Xiang

    2008-01-01

    A HPLC-MS fingerprint method has been developed based on the consistent chromatographic features of the major chemical constituents among 10 batches of Hedyotis diffusa Willd. Chromatographic separation was conducted on a Hypersil-Keystone Hypurity C(18) column using methanol:water:acetic acid as the mobile phase. Major compounds, including oleanolic acid, ursolic acid and ferulic acid, were analysed by HPLC-MS. Their analysis was ascertained by comparison with data derived from the standard compounds. The HPLC-MS fingerprint was successfully applied to analyse and differentiate samples from different geographical origins, or processing methods. H. diffusa was well distinguished from Hedyotis chrysotricha by HPLC-MS. Therefore the establishment of fingerprint of H. diffusa is critical in assessing and controlling its overall quality.

  11. Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids.

    PubMed

    Chocholouš, Petr; Vacková, Jana; Srámková, Ivana; Satínský, Dalibor; Solich, Petr

    2013-01-15

    Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Very large scale monoclonal antibody purification: the case for conventional unit operations.

    PubMed

    Kelley, Brian

    2007-01-01

    Technology development initiatives targeted for monoclonal antibody purification may be motivated by manufacturing limitations and are often aimed at solving current and future process bottlenecks. A subject under debate in many biotechnology companies is whether conventional unit operations such as chromatography will eventually become limiting for the production of recombinant protein therapeutics. An evaluation of the potential limitations of process chromatography and filtration using today's commercially available resins and membranes was conducted for a conceptual process scaled to produce 10 tons of monoclonal antibody per year from a single manufacturing plant, a scale representing one of the world's largest single-plant capacities for cGMP protein production. The process employs a simple, efficient purification train using only two chromatographic and two ultrafiltration steps, modeled after a platform antibody purification train that has generated 10 kg batches in clinical production. Based on analyses of cost of goods and the production capacity of this very large scale purification process, it is unlikely that non-conventional downstream unit operations would be needed to replace conventional chromatographic and filtration separation steps, at least for recombinant antibodies.

  13. Direct injection analysis of fatty and resin acids in papermaking process waters by HPLC/MS.

    PubMed

    Valto, Piia; Knuutinen, Juha; Alén, Raimo

    2011-04-01

    A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Effects of urban debris material on the extraction chromatographic separation of strontium—part I: steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLain, Derek R.; Amato, Victoria; Sudowe, Ralf

    An incident involving a radiation dispersal device (RDD) would most likely occur in an urban or metropolitan area. However, the majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. 90Sr is one of the possible radioisotopes that could be used in an RDD. It is therefore important to find efficient and accurate ways to separate it from debris in the area of deployment. Finally, this research demonstrates that the presence of steel in dissolved samples shows no appreciable interference with extraction chromatographic separations. Instead, itmore » indicates that the separation could actually be improved by the presence of the steel constituents.« less

  15. Effects of urban debris material on the extraction chromatographic separation of strontium—part I: steel

    DOE PAGES

    McLain, Derek R.; Amato, Victoria; Sudowe, Ralf

    2017-10-31

    An incident involving a radiation dispersal device (RDD) would most likely occur in an urban or metropolitan area. However, the majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. 90Sr is one of the possible radioisotopes that could be used in an RDD. It is therefore important to find efficient and accurate ways to separate it from debris in the area of deployment. Finally, this research demonstrates that the presence of steel in dissolved samples shows no appreciable interference with extraction chromatographic separations. Instead, itmore » indicates that the separation could actually be improved by the presence of the steel constituents.« less

  16. HPLC, MS, and pharmacokinetics of melphalan, bisantrene and 13-cis retinoic acid.

    PubMed

    Davis, T P; Peng, Y M; Goodman, G E; Alberts, D S

    1982-11-01

    High performance liquid chromatographic procedures are described for melphalan, bisantrene, and 13-cis retinoic acid, three important anticancer drugs in various stages of clinical development. The procedures require a rapid and simple sample clean-up followed by a 10-to 20-min chromatographic separation on a reversed-phase C18 column. Precisions are all less than 8% with recoveries greater than 80%. Mass spectrometry confirmation of each drug from patient sample separations is presented to provide unambiguous identification for valid pharmacokinetic parameter determination.

  17. PROCESS FOR SEPARATING IODINE-132 FROM FISSION PRODUCTS

    DOEpatents

    Greene, M.W.; Tucker, W.D.; Samos, G.

    1960-06-28

    A process is given for isolating I/sup 132/ in substantially pure form. Te/sup 132/, which is the radioactive parent of I/sup 132/, is adsorbed on a finely divided mass of a chromatographic grade of refractory metal oxide. i.e., alumina, zirconia, titania, and ceria. After a period of time is allowed for the Te/sup 132/ to decay, a 0.001 to 0.01 molar solution of ammonium hydroxide is passed over the finely divided oxides and the I/sup 132/ values are eluted.

  18. Chromato-fluorographic drug detector. [device for detecting and recording fluorescent properties of materials

    NASA Technical Reports Server (NTRS)

    Parker, J. A.; Dimeff, J.; Heimbuch, A. H. (Inventor)

    1974-01-01

    A drug detecting apparatus which includes a chromatographic system for separating particular substances from a sample solution passed through it is described. A source of radiation causes the substance to emit fluorescent radiation as it moves through the chromatographic system. An optical system spectrally separates the fluorescent radiation according to wavelength and for focusing particular portions of the separated spectrum through an exit aperture. A photodetector which is responsive to the radiation passing through the exit aperture develops an electrical signal commensurate with the intensity of the radiation. The electrical signal is recorded to provide an indication of certain characteristics of the substance.

  19. Analysis of benzo(a)pyrene in airborne particulates by gas chromatography

    NASA Technical Reports Server (NTRS)

    Luedecke, E.

    1976-01-01

    A routine method was developed to measure benzo(a)pyrene in airborne particulates. Samples were collected on a filter and the organic portion was extracted with cyclohexane. The polynuclear hydrocarbon (PNHC) fraction was separated from the aliphatics by column chromatography. An internal standard was added to the extract and a portion of it was injected into a gas chromatograph. Although the gas chromatographic method has often been reported in the literature, satisfactory separation of benzo(a)pyrene and benzo(e)pyrene has not been achieved. With the introduction of a nematic liquid crystal as the stationary phase good separation is now possible.

  20. Polar Aprotic Modifiers for Chromatographic Separation and Back-Exchange Reduction for Protein Hydrogen/Deuterium Exchange Monitored by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Valeja, Santosh G.; Emmett, Mark R.; Marshall, Alan G.

    2012-04-01

    Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein-protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent.

  1. Gas-liquid chromatography with a volatile "stationary" liquid phase.

    PubMed

    Wells, P S; Zhou, S; Parcher, J F

    2002-05-01

    A unique type of gas-liquid chromatography is described in which both mobile and "stationary" phases are composed of synthetic mixtures of helium and carbon dioxide. At temperatures below the critical point of the binary mixture and pressures above the vapor pressure of pure liquid carbon dioxide, helium and carbon dioxide can form two immiscible phases over extended composition ranges. A binary vapor phase enriched in helium can act as the mobile phase for chromatographic separations, whereas a CO2-rich liquid in equilibrium with the vapor phase, but condensed on the column wall, can act as a pseudostationary phase. Several examples of chromatographic separations obtained in "empty" capillary columns with no ordinary stationary liquid phase illustrate the range of conditions that produce such separations. In addition, several experiments are reported that confirm the proposed two-phase hypothesis. The possible consequences of the observed chromatographic phenomenon in the field of supercritical fluid chromatography with helium headspace carbon dioxide are discussed.

  2. Enrichment and separation of chlorogenic acid from the extract of Eupatorium adenophorum Spreng by macroporous resin.

    PubMed

    Liu, Boyan; Dong, Beitao; Yuan, Xiaofan; Kuang, Qirong; Zhao, Qingsheng; Yang, Mei; Liu, Jie; Zhao, Bing

    2016-01-01

    A simple and efficient chromatographic method for separation of chlorogenic acid from Eupatorium adenophorum Spreng extract was developed. The adsorption properties of nine macroporous resins were evaluated. NKA-II resin showed much better adsorption/desorption properties. The adsorption of chlorogenic acid on NKA-II resin at 25°C was well fitted to Langmuir isotherm model and pseudo-second-order kinetic model. The dynamic adsorption and desorption experiments were carried out on columns packed with NKA-II resin to optimize the separation process. The content of chlorogenic acid in the product increased to 22.17%, with a recovery yield of 82.41%. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.

    PubMed

    Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El

    2017-06-27

    HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  4. Artificial neural network model for photosynthetic pigments identification using multi wavelength chromatographic data

    NASA Astrophysics Data System (ADS)

    Prilianti, K. R.; Hariyanto, S.; Natali, F. D. D.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2016-04-01

    The development of rapid and automatic pigment characterization method become an important issue due to the fact that there are only less than 1% of plant pigments in the earth have been explored. In this research, a mathematical model based on artificial intelligence approach was developed to simplify and accelerate pigment characterization process from HPLC (high-performance liquid chromatography) procedure. HPLC is a widely used technique to separate and identify pigments in a mixture. Input of the model is chromatographic data from HPLC device and output of the model is a list of pigments which is the spectrum pattern is discovered in it. This model provides two dimensional (retention time and wavelength) fingerprints for pigment characterization which is proven to be more accurate than one dimensional fingerprint (fixed wavelength). Moreover, by mimicking interconnection of the neuron in the nervous systems of the human brain, the model have learning ability that could be replacing expert judgement on evaluating spectrum pattern. In the preprocessing step, principal component analysis (PCA) was used to reduce the huge dimension of the chromatographic data. The aim of this step is to simplify the model and accelerate the identification process. Six photosynthetic pigments i.e. zeaxantin, pheophytin a, α-carotene, β-carotene, lycopene and lutein could be well identified by the model with accuracy up to 85.33% and processing time less than 1 second.

  5. GC-MS (GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC) SUITABILITY TESTING OF RCRA APPENDIX VIII AND MICHIGAN LIST ANALYTES

    EPA Science Inventory

    As a first step in a hierarchical scheme to demonstrate the suitability of present U.S. Environmental Protection Agency (USEPA) analysis methods and/or develop new methodology, the gas chromatographic (GC) separation and mass spectrometric (MS) detection characteristics of 328 to...

  6. Liquid Crystals in Chromatography

    NASA Astrophysics Data System (ADS)

    Witkiewicz, Zygfryd

    The following sections are included: * INTRODUCTION * LIQUID CRYSTALS SUITABLE FOR GAS CHROMATOGRAPHY * Monomeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Polymeric Liquid Crystal Stationary Phases * Conventional Analytical Columns * Capillary Columns * FACTORS AFFECTING THE CHROMATOGRAPHIC SEPARATIONS ON LIQUID CRYSTAL STATIONARY PHASES * Kind of Mesophase of the Liquid Crystal * Molecular Structure of the Liquid Crystals and of the Chromatographed Substances * Substrate on which the Liquid Crystal is Deposited * ANALYTICAL APPLICATIONS OF LIQUID CRYSTAL STATIONARY PHASES IN GAS CHROMATOGRAPHY * Separation of Isomers of Benzene and Naphthalene Derivatives * Separation of Alkane and Alkene Isomers * Separation of Mixtures of Benzene and Aliphatic Hydrocarbon Derivatives Containing Heteroatoms * Separation of Polynuclear Hydrocarbons * INVESTIGATION OF THE PROPERTIES OF LIQUID CRYSTALS BY GAS CHROMATOGRAPHY * APPLICATION OF LIQUID CRYSTALS IN LIQUID CHROMATOGRAPHY * Column Chromatography * Thin-Layer Chromatography * APPLICATION OF LIQUID CRYSTAL STATIONARY PHASES IN SUPERCRITICAL FLUID CHROMATOGRAPHY * FINAL REMARKS * References

  7. Ionic liquids in chromatographic and electrophoretic techniques: toward additional improvements in the separation of natural compounds

    PubMed Central

    Freire, Carmen S. R.; Coutinho, João A. P.; Silvestre, Armando J. D.; Freire, Mara G.

    2016-01-01

    Due to their unique properties, in recent years, ionic liquids (ILs) have been largely investigated in the field of analytical chemistry. Particularly during the last sixteen years, they have been successfully applied in the chromatographic and electrophoretic analysis of value-added compounds extracted from biomass. Considering the growing interest in the use of ILs in this field, this critical review provides a comprehensive overview on the improvements achieved using ILs as constituents of mobile or stationary phases in analytical techniques, namely in capillary electrophoresis and its different modes, in high performance liquid chromatography, and in gas chromatography, for the separation and analysis of natural compounds. The impact of the IL chemical structure and the influence of secondary parameters, such as the IL concentration, temperature, pH, voltage and analysis time (when applied), are also critically addressed regarding the achieved separation improvements. Major conclusions on the role of ILs in the separation mechanisms and the performance of these techniques in terms of efficiency, resolution and selectivity are provided. Based on a critical analysis of all published results, some target-oriented ILs are suggested. Finally, current drawbacks and future challenges in the field are highlighted. In particular, the design and use of more benign and effective ILs as well as the development of integrated (and thus more sustainable) extraction–separation processes using IL aqueous solutions are suggested within a green chemistry perspective. PMID:27667965

  8. Systematic Evaluation of Chromatographic Parameters for Isoquinoline Alkaloids on XB-C18 Core-Shell Column Using Different Mobile Phase Compositions

    PubMed Central

    Sowa, Ireneusz; Zielińska, Sylwia; Sawicki, Jan; Bogucka-Kocka, Anna; Staniak, Michał; Bartusiak-Szcześniak, Ewa; Podolska-Fajks, Maja; Kocjan, Ryszard

    2018-01-01

    Chelidonium majus L. is a rich source of isoquinoline alkaloids with confirmed anti-inflammatory, choleretic, spasmolytic, antitumor, and antimicrobial activities. However, their chromatographic analysis is difficult because they may exist both in charged and uncharged forms and may result in the irregular peak shape and the decrease in chromatographic system efficacy. In the present work, the separation of main C. majus alkaloids was optimized using a new-generation XB-C18 endcapped core-shell column dedicated for analysis of alkaline compounds. The influence of organic modifier concentration, addition of salts, and pH of eluents on chromatographic parameters such as retention, resolution, chromatographic plate numbers, and peak asymmetry was investigated. The results were applied to elaborate the optimal chromatographic system for simultaneous quantification of seven alkaloids from the root, herb, and fruit of C. majus. PMID:29675288

  9. Stochastic theory of size exclusion chromatography by the characteristic function approach.

    PubMed

    Dondi, Francesco; Cavazzini, Alberto; Remelli, Maurizio; Felinger, Attila; Martin, Michel

    2002-01-18

    A general stochastic theory of size exclusion chromatography (SEC) able to account for size dependence on both pore ingress and egress processes, moving zone dispersion and pore size distribution, was developed. The relationship between stochastic-chromatographic and batch equilibrium conditions are discussed and the fundamental role of the 'ergodic' hypothesis in establishing a link between them is emphasized. SEC models are solved by means of the characteristic function method and chromatographic parameters like plate height, peak skewness and excess are derived. The peak shapes are obtained by numerical inversion of the characteristic function under the most general conditions of the exploited models. Separate size effects on pore ingress and pore egress processes are investigated and their effects on both retention selectivity and efficiency are clearly shown. The peak splitting phenomenon and peak tailing due to incomplete sample sorption near to the exclusion limit is discussed. An SEC model for columns with two types of pores is discussed and several effects on retention selectivity and efficiency coming from pore size differences and their relative abundance are singled out. The relevance of moving zone dispersion on separation is investigated. The present approach proves to be general and able to account for more complex SEC conditions such as continuous pore size distributions and mixed retention mechanism.

  10. Chaotropic salts in liquid chromatographic method development for the determination of pramipexole and its impurities following quality-by-design principles.

    PubMed

    Vemić, Ana; Rakić, Tijana; Malenović, Anđelija; Medenica, Mirjana

    2015-01-01

    The aim of this paper is to present a development of liquid chromatographic method when chaotropic salts are used as mobile phase additives following the QbD principles. The effect of critical process parameters (column chemistry, salt nature and concentration, acetonitrile content and column temperature) on the critical quality attributes (retention of the first and last eluting peak and separation of the critical peak pairs) was studied applying the design of experiments-design space methodology (DoE-DS). D-optimal design is chosen in order to simultaneously examine both categorical and numerical factors in minimal number of experiments. Two ways for the achievement of quality assurance were performed and compared. Namely, the uncertainty originating from the models was assessed by Monte Carlo simulations propagating the error equal to the variance of the model residuals and propagating the error originating from the model coefficients' calculation. The baseline separation of pramipexole and its five impurities is achieved fulfilling all the required criteria while the method validation proved its reliability. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Comparison of large scale purification processes of naproxen enantiomers by chromatography using methanol-water and methanol-supercritical carbon dioxide mobile phases.

    PubMed

    Kamarei, Fahimeh; Vajda, Péter; Guiochon, Georges

    2013-09-20

    This paper compares two methods used for the preparative purification of a mixture of (S)-, and (R)-naproxen on a Whelk-O1 column, using either high performance liquid chromatography or supercritical fluid chromatography. The adsorption properties of both enantiomers were measured by frontal analysis, using methanol-water and methanol-supercritical carbon dioxide mixtures as the mobile phases. The measured adsorption data were modeled, providing the adsorption isotherms and their parameters, which were derived from the nonlinear fit of the isotherm models to the experimental data points. The model used was a Bi-Langmuir isotherm, similar to the model used in many enantiomeric separations. These isotherms were used to calculate the elution profiles of overloaded elution bands, assuming competitive Bi-Langmuir behavior of the two enantiomers. The analysis of these profiles provides the basis for a comparison between supercritical fluid chromatographic and high performance liquid chromatographic preparative scale separations. It permits an illustration of the advantages and disadvantages of these methods and a discussion of their potential performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. A field-deployable GC-EI-HRTOF-MS for in situ characterization of volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Lerner, B. M.; Herndon, S. C.; Yacovitch, T. I.; Roscioli, J. R.; Fortner, E.; Knighton, W. B.; Sueper, D.; Isaacman-VanWertz, G. A.; Jayne, J. T.; Worsnop, D. R.

    2017-12-01

    Previous authors have demonstrated the value of coupling conventional gas chromatograph (GC) separation techniques with the new generation of electron-impact high-resolution time-of-flight mass spectrometry (EI-HR-ToF-MS) detectors for the measurement of halocarbons and semi-volatile organic species. Here, we present new instrumentation, analytical techniques and field data from the deployment of a GC-EI-HR-ToF-MS system in the mini Aerodyne mobile laboratory to sites upwind and downwind of San Antonio, Texas in May 2017. The instrument employed a multi-component adsorbent trap pre-concertation system followed by single-column separation. We will show results from the field work, including inter-comparison with other VOC measurements and characterization of C5-C10 hydrocarbon mixing ratios to distinguish urban and oil/gas emission sources in characterized air. We will discuss practical aspects of deployment of the GC-EI-HRTOF-MS in a mobile laboratory and system performance in the field. Will we also present further development of Aerodyne's TERN software package for chromatographic data analysis to processing of HRTOF-MS datasets.

  13. [Progresses in screening active compounds from herbal medicine by affinity chromatography].

    PubMed

    Feng, Ying-shu; Tong, Shan-shan; Xu, Xi-ming; Yu, Jiang-nan

    2015-03-01

    Affinity chromatography is a chromatographic method for separating molecules using the binding characteristics of the stationary phase with potential drug molecules. This method can be performed as a high throughput screening method and a chromatographic separation method to screen a variety of active drugs. This paper summarizes the history of affinity chromatography, screening technology of affinity chromatography, and application of affinity chromatography in screening bio-active compounds in herbal medicines, and then discusses its application prospects, in order to broaden applications of the affinity chromatography in drug screening.

  14. Chromatographic column evaluation for the untargeted profiling of glucosinolates in cauliflower by means of ultra-high performance liquid chromatography coupled to high resolution mass spectrometry.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Montone, Carmela Maria; Piovesana, Susy; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2018-03-01

    The untargeted profiling is a promising approach for the characterization of secondary metabolites in biological matrices. Thanks to the recent rapid development of high-resolution mass spectrometry (HRMS) instrumentations, the number of applications by untargeted approaches for biological samples profiling has widely increased in the recent years. Despite the high potentialities of HRMS, however, a major issue in natural products analysis often arises in the upstream process of compounds separation. A separation technique is necessary to avoid phenomena such as signal suppression, and it is especially needed in the presence of isomeric metabolites, which are otherwise indistinguishable. Glucosinolates (GLSs), a group of secondary metabolites widely distributed among plants, resulted to be associated to the prevention of some serious diseases, such as cancer. This led to the development of several methods for the analysis of GLSs in vegetables tissues. The issue of GLSs chromatographic separation has been widely studied in the past because of the difficulty in the analysis of this highly polar and variable class of compounds. Several alternatives to reversed phase (RP) chromatography, sometimes not compatible with the coupling of liquid chromatography with mass spectrometry, have been tested for the analysis of intact GLSs. However, the availability of new stationary phases, in the last years, could allow the re-evaluation of RP chromatography for the analysis of intact GLSs. In this work, a thorough evaluation of four RP chromatographic columns for the analysis of GLSs in cauliflower (Brassica oleracea L. var. botrytis) extracts by an ultra-high performance liquid chromatographic system coupled via electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer is presented. The columns tested were the following: one column Luna Omega polar C 18 , one column Kinetex Biphenyl, one column Kinetex core-shell XB-C 18 , two columns Kinetex core-shell XB-C 18 . After a previous optimization of the extraction method, cauliflower extracts were analyzed testing four different mobile phases onto the four columns for a total of sixteen different chromatographic conditions. The chromatographic systems were evaluated based on the number of detected and tentatively identified GLSs. Luna Polar stationary phase resulted to be the most suitable for the analysis of GLSs compared to Kinetex XB and Kinetex Biphenyl columns stationary phase. However, two in series Kinetex XB columns increased the number of tentatively identified GLSs compared to one Kinetex XB, showing the importance of column length in the analysis of complex mixtures. The data obtained with the best chromatographic system were deeply analyzed by MS/MS investigation for the final identification. Fiflty-one GLSs were tentatively identified, 24 of which have never been identified in cauliflower. Finally the linearity of the analytes response over the analyzed range of concentration was checked, suggesting that the developed method is suitable for both qualitative and quantitative analysis of GLSs in phytochemical mixtures. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Molecular separations using nanostructured porous thin films fabricated by glancing angle deposition

    NASA Astrophysics Data System (ADS)

    Bezuidenhout, Louis Wentzel

    Biomolecular separation techniques are an enabling technology that indirectly in.uence many aspects of our lives. Advances have led to faster analyses, reduced costs, higher specificity, and new analytical techniques, impacting areas such as health care, environmental monitoring, polymer sciences, agriculture, and nutrition. Further development of separations technology is anticipated to follow the path of computing technology such that miniaturization through the development of microfluidics technology, lab-on-a-chip systems, and other integrative, multi-component systems will further extend our analysis capabilities. Creation of new and improvement of existing separation technologies is an integral part of the pathway to miniaturized systems. the work of this thesis investigates molecular separations using porous nanostructured films fabricated by the thin film process glancing angle deposition (GLAD). Structural architecture, pore size and shape, and film density can be finely controlled to produce high-surface area thin films with engineered morphology. The characteristic size scales and structural control of GLAD films are well-suited to biomolecules and separation techniques, motivating investigation into the utility and performance of GLAD films for biomolecular separations. This project consisted of three phases. First, chromatographic separation of dye molecules on silica GLAD films was demonstrated by thin layer chromatography Direct control of film nanostructure altered the separation characteristics; most strikingly, anisotropic structures provided two-dimensional analyte migration. Second, nanostructures made with GLAD were integrated in PDMS microfluidic channels using a sacrificial etching process; DNA molecules (10/48 kbp and 6/10/20 kbp mixtures) were electrophoretically separated on a microfluidic chip using a porous bed of SiO2 vertical posts. Third, mass spectrometry of proteins and drugs in the mass range of 100-1300 m/z was performed using laser desorption/ionization (LDI) on silicon GLAD films, and the influence of film thickness, porosity, structure, and substrate on performance was characterized. The application of GLAD nanostructured thin films to biomolecular separations is demonstrated and validated in this thesis. Chromatographic separation of dye molecules, electrophoretic separation of DNA molecules, and mass spectrometric isolation of small proteins and drug molecules by laser desorption ionization were demonstrated using GLAD films. All three methods yielded promising results and establish GLAD as a potential technology for biomolecular separations.

  16. Identification and phylogeny of Arabian snakes: Comparison of venom chromatographic profiles versus 16S rRNA gene sequences.

    PubMed

    Al Asmari, Abdulrahman; Manthiri, Rajamohammed Abbas; Khan, Haseeb Ahmad

    2014-11-01

    Identification of snake species is important for various reasons including the emergency treatment of snake bite victims. We present a simple method for identification of six snake species using the gel filtration chromatographic profiles of their venoms. The venoms of Echis coloratus, Echis pyramidum, Cerastes gasperettii, Bitis arietans, Naja arabica, and Walterinnesia aegyptia were milked, lyophilized, diluted and centrifuged to separate the mucus from the venom. The clear supernatants were filtered and chromatographed on fast protein liquid chromatography (FPLC). We obtained the 16S rRNA gene sequences of the above species and performed phylogenetic analysis using the neighbor-joining method. The chromatograms of venoms from different snake species showed peculiar patterns based on the number and location of peaks. The dendrograms generated from similarity matrix based on the presence/absence of particular chromatographic peaks clearly differentiated Elapids from Viperids. Molecular cladistics using 16S rRNA gene sequences resulted in jumping clades while separating the members of these two families. These findings suggest that chromatographic profiles of snake venoms may provide a simple and reproducible chemical fingerprinting method for quick identification of snake species. However, the validation of this methodology requires further studies on large number of specimens from within and across species.

  17. Characterization of coal liquids derived from the H-coal process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, S.A.; Woodward, P.W.; Sturm, G.P. Jr.

    1976-11-01

    Compositional data of coal liquid products derived from the H-Coal process were obtained. Two overhead products (one from the fuel oil mode of operation and the other from the syncrude mode of operation) were prepared by Hydrocarbon Research, Inc. from Illinois No. 6 coal. The compositional data of these products are tabulated, and characteristics of the materials are discussed. Separation and characterization methods, with slight modification, as developed by the Bureau of Mines-API Research Project 60 for characterizing heavy ends of petroleum, were successfully used in analyzing coal liquid distillates within the boiling range 200/sup 0/ to 540/sup 0/C. Distillatesmore » boiling below 200/sup 0/C were separated and analyzed using chromatographic and spectral techniques.« less

  18. Comprehensive chemical comparison of fuel composition and aerosol particles emitted from a ship diesel engine by gas chromatography atmospheric pressure chemical ionisation ultra-high resolution mass spectrometry with improved data processing routines.

    PubMed

    Rüger, Christopher P; Schwemer, Theo; Sklorz, Martin; O'Connor, Peter B; Barrow, Mark P; Zimmermann, Ralf

    2017-02-01

    The analysis of petrochemical materials and particulate matter originating from combustion sources remains a challenging task for instrumental analytical techniques. A detailed chemical characterisation is essential for addressing health and environmental effects. Sophisticated instrumentation, such as mass spectrometry coupled with chromatographic separation, is capable of a comprehensive characterisation, but needs advanced data processing methods. In this study, we present an improved data processing routine for the mass chromatogram obtained from gas chromatography hyphenated to atmospheric pressure chemical ionisation and ultra high resolution mass spectrometry. The focus of the investigation was the primary combustion aerosol samples, i.e. particulate matter extracts, as well as the corresponding fossil fuels fed to the engine. We demonstrate that utilisation of the entire transient and chromatographic information results in advantages including minimisation of ionisation artefacts and a reliable peak assignment. A comprehensive comparison of the aerosol and the feed fuel was performed by applying intensity weighted average values, compound class distribution and principle component analysis. Certain differences between the aerosol generated with the two feed fuels, diesel fuel and heavy fuel oil, as well as between the aerosol and the feed were revealed. For the aerosol from heavy fuel oil, oxidised species from the CHN and CHS class precursors of the feed were predominant, whereas the CHO x class is predominant in the combustion aerosol from light fuel oil. Furthermore, the complexity of the aerosol increases significantly compared to the feed and incorporating a higher chemical space. Coupling of atmospheric pressure chemical ionisation to gas chromatography was found to be a useful additional approach for characterisation of a combustion aerosol, especially with an automated utilisation of the information from the ultra-high resolution mass spectrometer and the chromatographic separation.

  19. Optimal performance of single-column chromatography and simulated moving bed processes for the separation of optical isomers

    NASA Astrophysics Data System (ADS)

    Medi, Bijan; Kazi, Monzure-Khoda; Amanullah, Mohammad

    2013-06-01

    Chromatography has been established as the method of choice for the separation and purification of optically pure drugs which has a market size of about 250 billion USD. Single column chromatography (SCC) is commonly used in the development and testing phase of drug development while multi-column Simulated Moving Bed (SMB) chromatography is more suitable for large scale production due to its continuous nature. In this study, optimal performance of SCC and SMB processes for the separation of optical isomers under linear and overloaded separation conditions has been investigated. The performance indicators, namely productivity and desorbent requirement have been compared under geometric similarity for the separation of a mixture of guaifenesin, and Tröger's base enantiomers. SCC process has been analyzed under equilibrium assumption i.e., assuming infinite column efficiency, and zero dispersion, and its optimal performance parameters are compared with the optimal prediction of an SMB process by triangle theory. Simulation results obtained using actual experimental data indicate that SCC may compete with SMB in terms of productivity depending on the molecules to be separated. Besides, insights into the process performances in terms of degree of freedom and relationship between the optimal operating point and solubility limit of the optical isomers have been ascertained. This investigation enables appropriate selection of single or multi-column chromatographic processes based on column packing properties and isotherm parameters.

  20. Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications.

    PubMed

    Aral, Tarık; Aral, Hayriye; Ziyadanoğulları, Berrin; Ziyadanoğulları, Recep

    2015-01-01

    A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 µm, 60 Å). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20°C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and detected at 230 or 278 nm. The best separation conditions for seven phenolic compounds was also achieved using reversed-phase HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10mM) and acetonitrile with 20°C column temperature and seven phenolic compounds could be separated and detected at 230 nm within 16 min. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Effects of the dynamic modification of stationary phases by sorbates in gas chromatography: The possibility of separating enantiomers in achiral systems

    NASA Astrophysics Data System (ADS)

    Zenkevich, I. G.; Pavlovskii, A. A.

    2016-10-01

    It is shown that the gas chromatographic separation of enantiomers on columns with achiral nonpolar stationary phases is principally possible as a result of the dynamic modification of stationary phases by sorbates under analysis. It is found that a number of key characteristic features is intrinsic to such separation: it can be only partial, it does not occur for all chromatographic columns, and it is observed only for some compounds and only within narrow ranges of quantities of sorbates that are close to the limits of mass overload of chromatographic systems. These characteristic features are illustrated by the examples of separating (1 R,5 R)-(+)- and (1 S,5 S)-(-)-α-pinenes on a WCOT column with an RTX-5 phase. The main characteristic feature of the separation of enantiomers as a result of the dynamic modification of stationary phases is the nonconformity of peaks in chromatograms with two individual enantiomers, compared to other ways and means for their separation; the first eluting peak belongs to the enantiomer that predominates in a mixture irrespective of its configuration, while the second peak corresponds to the racemic mixture of enantiomers; i.e., the ratio of peak areas in chromatograms does not correspond to the actual ratio of enantiomers in samples under analysis and is strongly distorted as a result of their incomplete separation. It is concluded that the separation of racemic mixtures in achiral systems is fundamentally impossible under any conditions, and this is one of the key criteria of the validity of the considered concept as a whole.

  2. An automated multidimensional preparative gas chromatographic system for isolation and enrichment of trace amounts of xenon from ambient air.

    PubMed

    Larson, Tuula; Östman, Conny; Colmsjö, Anders

    2011-04-01

    The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.

  3. Pushing the speed limit in enantioselective supercritical fluid chromatography.

    PubMed

    Regalado, Erik L; Welch, Christopher J

    2015-08-01

    Chromatographic enantioseparations on the order of a few seconds can be achieved by supercritical fluid chromatography using short columns packed with chiral stationary phases. The evolution of 'world record' speeds for the chromatographic separation of enantiomers has steadily dropped from an industry standard of 20-40 min just two decades ago, to a current ability to perform many enantioseparations in well under a minute. Improvements in instrument and column technologies enabled this revolution, but the ability to predict optimal separation time from an initial method development screening assay using the t(min cc) predictor greatly simplifies the development and optimization of high-speed chiral chromatographic separations. In this study, we illustrate how the use of this simple tool in combination with the workhorse technique of supercritical fluid chromatography on customized short chiral columns (1-2 cm length) allows us to achieve ultrafast enantioseparations of pharmaceutically relevant compounds on the 5-20 s scale, bringing the technique of high-throughput enantiopurity analysis out of the specialist realm and into the laboratories of most researchers. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. RECOVERY OF PROTACTINIUM

    DOEpatents

    Kraus, K.A.; Moore, G.E.

    1959-02-01

    A process is presented for the separation of protactinium values from an aqueous solution containing Pa and Th values comprising establishing in the solution a HCl concentration of from 4 to 11 molar, contacting the resulting solution with an anion-exchange adsorbent, such as a polystyrene divinyl benzene polymer with quatenary amines as the active exchange group, to effect the adsorption of Pa values upon the adsorbent while leaving Th values in the solution, and then washlng the separated Pa bearing adsorbent with an aqueous solution of HCl of less than 4M to exclusively elute Pa values from the adsorbent. If hexavalent U values are contained in the original solution thcy are adsorbed on the resin together with Pa. A separation is offected chromatographically by percolating the resin with aqueous HCl.

  5. Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Zondlo, Mark A.; Bomse, David S.

    2005-01-01

    The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.

  6. Chromatographic fingerprint analysis of yohimbe bark and related dietary supplements using UHPLC/UV/MS.

    PubMed

    Sun, Jianghao; Chen, Pei

    2012-03-05

    A practical ultra high-performance liquid chromatography (UHPLC) method was developed for fingerprint analysis of and determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved using a Waters Acquity BEH C(18) column with gradient elution using 0.1% (v/v) aqueous ammonium hydroxide and 0.1% ammonium hydroxide in methanol as the mobile phases. The study is the first reported chromatographic method that separates corynanthine from yohimbine in yohimbe bark extract. The chromatographic fingerprint analysis was applied to the analysis of 18 yohimbe commercial dietary supplement samples. Quantitation of yohimbine, the traditional method for analysis of yohimbe barks, were also performed to evaluate the results of the fingerprint analysis. Wide variability was observed in fingerprints and yohimbine content among yohimbe dietary supplement samples. For most of the dietary supplements, the yohimbine content was not consistent with the label claims. Copyright © 2011. Published by Elsevier B.V.

  7. Green Chromatographic Separation of Coumarin and Vanillins Using Subcritical Water as the Mobile Phase.

    PubMed

    Kayan, Berkant; Akay, Sema; Yang, Yu

    2016-08-01

    Pure water was used as the eluent for separation of coumarin, vanillin and ethyl vanillin at temperatures ranging from 100 to 200°C using a homemade subcritical water chromatography (SBWC) system. Chromatographic separations were performed on five commercial columns including XTerra MS C18, XBridge C18, Zorbax RRHD Eclipse Plus, Zorbax SB-Phenyl and Zorbax SB-C18 columns. The retention time of all three solutes decreased with increasing water temperature. The shortest retention time among all acceptable separations, less than 4 min, was achieved on the Zorbax SB-C18 column at 200°C. While separations on the XTerra MS C18 column resulted in fronting peaks and a degradation peak from ethyl vanillin on the Zorbax RRHD Eclipse Plus column was observed, all three other columns yielded reasonable separations under SBWC conditions. In addition to separation of the standard test mixture, separation of coumarin contained in a skincare cream sample was also carried out using SBWC. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. ABSORPTION METHOD FOR SEPARATING METAL CATIONS

    DOEpatents

    Tompkins, E.R.; Parker, G.W.

    1959-03-10

    An improved method is presented for the chromatographic separation of fission products wherein a substantial reduction in liquid volume is obtained. The process consists in contacting a solution containing fission products with a body of ion-exchange adsorbent to effect adsorption of fission product cations. The loaded exchange resin is then contacted with a small volume of a carboxylic acid eluant, thereby recovering the fission products. The fission product carrying eluate is acidified without increasing its volume to the volume of the original solution, and the acidified eluate is then used as a feed solution for a smaller body of ion-exchange resin effecting readsorption of the fission product cations.

  9. Synthesis of zirconia monoliths for chromatographic separations.

    PubMed

    Randon, Jérôme; Huguet, Samuel; Piram, Anne; Puy, Guillaume; Demesmay, Claire; Rocca, Jean-Louis

    2006-03-17

    The aim of this work is to join the advantages of two different kinds of stationary phases: monolithic columns and zirconia-based supports. On the one hand, silica monolithic columns allow a higher efficiency with a lower back-pressure than traditional packed columns. On the other hand, chromatographic stationary phases based on zirconia have a higher thermal and chemical stability and specific surface properties. Combining these advantages, a zirconia monolith with a macroporous framework could be a real improvement in separation sciences. Two main strategies can be used in order to obtain a zirconia surface on a monolithic skeleton: coating or direct synthesis. The coverage by a zirconia layer of the surface of a silica-based monolith can be performed using the chemical properties of the silanol surface groups. We realized this coverage using zirconium alkoxide and we further grafted n-dodecyl groups using phosphate derivatives. Any loss of efficiency was observed and fast separations have been achieved. The main advance reported in this paper is related to the preparation of zirconia monoliths by a sol-gel process starting from zirconium alkoxide. The synthesis parameters (hydrolysis ratio, porogen type, precursor concentration, drying step, etc.) were defined in order to produce a macroporous zirconia monoliths usable in separation techniques. We produced various homogeneous structures: zirconia rod 2 cm long with a diameter of 2.3 mm, and zirconia monolith inside fused silica capillaries with a 75 microm I.D. These monoliths have a skeleton size of 2 microm and have an average through pore size of 6 microm. Several separations have been reported.

  10. [Analyzing crude/processed root of Polygonum multiflorum from different habitats by UPLC fingerprint and mode identification methods].

    PubMed

    Xiao, Rong; Lin, Yan; Lei, Si-Min; Zhang, Ying; Huang, Jie; Xia, Bo-Hou; Li, Chun; Liao, Duan-Fang; Wu, Ping; Lin, Li-Mei

    2017-06-01

    To establish a content determination method for 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside (TSG) of the crude/processed root of Polygonum multiflorum from different habitats in China and set up the fingerprint by using UPLC. Various samples were pretreated by macro-porous resin. Then UPLC analysis was performed on Waters ACQUITY UPLC@BEH C18 chromatographic column (2.1 mm×50 mm, 1.7 μm) at (25±5) ℃. A binary gradient elution system was composed of acetonitrile (phase A) and 0.5% acetic acid solution (phase B). Detection was performed at the wavelength of 254 nm, and the mobile flow rate was set at 0.3 mL•min⁻¹. Results showed that the yield of extraction of the 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside from root of P. multiflorum was all over 25.0% after macro-porous resin separation; an exclusive UPLC fingerprint method of the crude/processed root of P. multiflorum from different habitats was successfully set up and 17 chromatographic peaks were calibrated. Cluster analysis can not entirely distinguish the crude one from the processed one, while principal component analysis absolutely can. 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside is the composition that has largest differences in variable importance in projection (VIP) between crude and processed root of P. multiflorum. The separating method can gain high-purity 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside, and the determination method is simple, sensitive, reliable and can be used in fast identifying the crude/processed root of P. multiflorum or as a method for overall quality control of root of P. multiflorum. Copyright© by the Chinese Pharmaceutical Association.

  11. Assessment of the chromatographic lipophilicity of eight cephalosporins on different stationary phases.

    PubMed

    Dąbrowska, Monika; Starek, Małgorzata; Komsta, Łukasz; Szafrański, Przemysław; Stasiewicz-Urban, Anna; Opoka, Włodzimierz

    2017-04-01

    The retention behaviors were investigated for a series of eight cephalosporins in thin-layer chromatography (TLC) using stationary phases of RP-2, RP-8, RP-18, NH 2 , DIOL, and CN chemically bonded silica gel. Additionally, various binary mobile phases (water/methanol and water/acetone) were used in different volume proportions. The retention behavior of the analyzed molecules was defined by R M0 constant. In addition, reversed phase high performance liquid chromatography (RP-HPLC) was performed in lipophilicity studies by using immobilized artificial membrane (IAM) stationary phase. Obtained chromatographic data (R M0 and logk' IAM ) were correlated with the lipophilicity, expressed as values of the log calculated (logP calc ) and experimental (logP exp(shake-flask) ) partition coefficient. Principal component analysis (PCA) was applied in order to obtain an overview of similarity or dissimilarity among the analyzed compounds. Hierarchical cluster analysis (HCA) was performed to compare the separation characteristics of the applied stationary phases. This study was undertaken to identify the best chromatographic system and chromatographic data processing method to enable the prediction of logP values. A comprehensive chromatographic investigation into the retention of the analyzed cephalosporins revealed a similar behavior on RP-18, RP-8 and CN stationary phases. The weak correlations obtained between experimental and certain computed lipophilicity indices revealed that R M0 and PC1/RM are relevant lipophilicity parameters and the RP-8, CN and RP-18 plates are appropriate stationary phases for lipophilicity investigation, whereas computational approaches still cannot fully replace experimentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Monoclonal antibody fragment removal mediated by mixed mode resins.

    PubMed

    O'Connor, Ellen; Aspelund, Matthew; Bartnik, Frank; Berge, Mark; Coughlin, Kelly; Kambarami, Mutsa; Spencer, David; Yan, Huiming; Wang, William

    2017-05-26

    Efforts to increase monoclonal antibody expression in cell culture can result in the presence of fragmented species requiring removal in downstream processing. Capto adhere, HEA Hypercel, and PPA Hypercel anion exchange/hydrophobic interaction mixed mode resins were evaluated for their fragment removal capabilities and found to separate large hinge IgG1 antibody fragment (LHF) from monomer. Removal of greater than 75% of LHF population occurred at pH 8 and low conductivity. The mechanism of fragment removal was investigated in two series of experiments. The first experimental series consisted of comparison to chromatographic behavior on corresponding single mode resins. Both single mode anion exchange and hydrophobic interaction resins failed to separate LHF. The second experimental series studied the impact of phase modifiers, ethylene glycol, urea, and arginine on the mixed mode mediated removal. The addition of ethylene glycol decreased LHF removal by half. Further decreases in LHF separation were seen upon incubation with urea and arginine. Therefore, it was discovered that the purification is the result of a mixed mode phenomena dominated by hydrophobic interaction and hydrogen bonding effects. The site of interaction between the LHF and mixed mode resin was determined by chemical labeling of lysine residues with sulfo-NHS acetate. The labeling identified the antibody hinge and light chain regions as mediating the fragment separation. Sequence analysis showed that under separation conditions, a hydrophobic proline patch and hydrogen bonding serine and threonine residues mediate the hinge interaction with the Capto adhere ligand. Additionally, a case study is presented detailing the optimization of fragment removal using Capto adhere resin to achieve purity and yield targets in a manufacturing facility. This study demonstrated that mixed mode resins can be readily integrated into commercial antibody platform processes when additional chromatographic abilities are required. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  13. Continuous recovery of valine in a model mixture of amino acids and salt from Corynebacterium bacteria fermentation using a simulated moving bed chromatography.

    PubMed

    Park, Chanhun; Nam, Hee-Geun; Jo, Se-Hee; Wang, Nien-Hwa Linda; Mun, Sungyong

    2016-02-26

    The economical efficiency of valine production in related industries is largely affected by the performance of a valine separation process, in which valine is to be separated from leucine, alanine, and ammonium sulfate. Such separation is currently handled by a batch-mode hybrid process based on ion-exchange and crystallization schemes. To make a substantial improvement in the economical efficiency of an industrial valine production, such a batch-mode process based on two different separation schemes needs to be converted into a continuous-mode separation process based on a single separation scheme. To address this issue, a simulated moving bed (SMB) technology was applied in this study to the development of a continuous-mode valine-separation chromatographic process with uniformity in adsorbent and liquid phases. It was first found that a Chromalite-PCG600C resin could be eligible for the adsorbent of such process, particularly in an industrial scale. The intrinsic parameters of each component on the Chromalite-PCG600C adsorbent were determined and then utilized in selecting a proper set of configurations for SMB units, columns, and ports, under which the SMB operating parameters were optimized with a genetic algorithm. Finally, the optimized SMB based on the selected configurations was tested experimentally, which confirmed its effectiveness in continuous separation of valine from leucine, alanine, ammonium sulfate with high purity, high yield, high throughput, and high valine product concentration. It is thus expected that the developed SMB process in this study will be able to serve as one of the trustworthy ways of improving the economical efficiency of an industrial valine production process. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Direct probing of chromatography columns by laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    McGuffin, V. L.

    1992-12-01

    This report summarizes the progress and accomplishments of this research project from 1 Sep. 1989 to 28 Feb. 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe in supercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  15. Simultaneous LC determination of paracetamol and related compounds in pharmaceutical formulations using a carbon-based column.

    PubMed

    Monser, Lotfi; Darghouth, Frida

    2002-03-01

    A simple, rapid and convenient high performance liquid chromatographic method, which permits the simultaneous determination of paracetamol, 4-aminophenol and 4-chloracetanilide in pharmaceutical preparation has been developed. The chromatographic separation was achieved on porous graphitized carbon (PGC) column using an isocratic mixture of 80/20 (v/v) acetonitrile/0.05 M potassium phosphate buffer (pH 5.5) and ultraviolet detection at 244 nm. Correlation coefficient for calibration curves in the ranges 1-50 microg ml(-1) for paracetamol and 5-40 microg ml(-1) for 4-aminophenol and 4-chloroacetanilide were >0.99. The sensitivity of detection is 0.1 microg ml(-1) for paracetamol and 0.5 microg ml(-1) for 4-aminophenol and 4-chloroacetanilide. The proposed liquid chromatographic method was successfully applied to the analysis of commercially available paracetamol dosage forms with recoveries of 98-103%. It is suggested that the proposed method should be used for routine quality control and dosage form assay of paracetamol in pharmaceutical preparations. The chromatographic behaviour of the three compounds was examined under variable mobile phase compositions and pH, the results revealed that selectivity was dependent on the organic solvent and pH used. The retention selectivity of these compounds on PGC was compared with those of octadecylsilica (ODS) packing materials in reversed phase liquid chromatography. The ODS column gave little separation for the degradation product (4-aminophenol) from paracetamol, whereas PGC column provides better separation in much shorter time.

  16. Separation of Albumin, Ceruloplasmin, and Transferrin from Human Plasma.

    ERIC Educational Resources Information Center

    Barnes, Grady; Frieden, Earl

    1982-01-01

    Procedures are provided for separating the principal metalloproteins (albumin, ceruloplasmin, and transferrin) from plasma using column chromatographic techniques. The experiment can be completed in two separate three-hour laboratory periods during which column chromatography is illustrated and the effect of pH on charge and affinity of a protein…

  17. Chromatographic determination of the diffusion coefficients of light hydrocarbons in polymers

    NASA Astrophysics Data System (ADS)

    Yakubenko, E. E.; Korolev, A. A.; Chapala, P. P.; Bermeshev, M. V.; Kanat'eva, A. Yu.; Kurganov, A. A.

    2017-01-01

    Gas-chromatographic determination of the diffusion coefficients that allows for the compressibility of the mobile phase has been suggested. The diffusion coefficients were determined for light hydrocarbons C1-C4 in four polymers with a high free volume, which are candidates for use as gas-separating membranes. The diffusion coefficients calculated from chromatographic data were shown to be one or two orders of magnitude smaller than the values obtained by the membrane method. This may be due to the presence of an additional flow through the membrane caused by the pressure gradient across the membrane in membrane methods.

  18. Physicochemical properties of sorbents based on silica gel modified by 1-phenylazo-2-naphtholic complexes of transition metals

    NASA Astrophysics Data System (ADS)

    Makarycheva, A. I.; Slizhov, Yu. G.

    2017-09-01

    Gas chromatography sorbents based on Silokhrom C80 and modified by 1-phenylazo-2-naphtholic complexes of 3 d metals (Co(II), Ni(II), Cu(II)) are obtained. Their structural, chromatographic, and sorption characteristics are investigated. It is found that modifying them with 1-phenylazo-2-naphthols of transition metals has a considerable effect on the chromatographic polarity and selectivity of sorption materials. The prospects for the practical application of the obtained sorbents are demonstrated by experiments on the gas chromatographic separation of mixtures of different classes of organic compounds.

  19. Application of Carbon Nanotubes in Chiral and Achiral Separations of Pharmaceuticals, Biologics and Chemicals

    PubMed Central

    Hemasa, Ayman L.; Maher, William A.; Ghanem, Ashraf

    2017-01-01

    Carbon nanotubes (CNTs) possess unique mechanical, physical, electrical and absorbability properties coupled with their nanometer dimensional scale that renders them extremely valuable for applications in many fields including nanotechnology and chromatographic separation. The aim of this review is to provide an updated overview about the applications of CNTs in chiral and achiral separations of pharmaceuticals, biologics and chemicals. Chiral single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) have been directly applied for the enantioseparation of pharmaceuticals and biologicals by using them as stationary or pseudostationary phases in chromatographic separation techniques such as high-performance liquid chromatography (HPLC), capillary electrophoresis (CE) and gas chromatography (GC). Achiral MWCNTs have been used for achiral separations as efficient sorbent objects in solid-phase extraction techniques of biochemicals and drugs. Achiral SWCNTs have been applied in achiral separation of biological samples. Achiral SWCNTs and MWCNTs have been also successfully used to separate achiral mixtures of pharmaceuticals and chemicals. Collectively, functionalized CNTs have been indirectly applied in separation science by enhancing the enantioseparation of different chiral selectors whereas non-functionalized CNTs have shown efficient capabilities for chiral separations by using techniques such as encapsulation or immobilization in polymer monolithic columns. PMID:28718832

  20. Isocratic non-aqueous reversed-phase high-performance liquid chromatographic separation of capsanthin and capsorubin in red peppers (Capsicum annuum L.), paprika and oleoresin.

    PubMed

    Weissenberg, M; Schaeffler, I; Menagem, E; Barzilai, M; Levy, A

    1997-01-03

    A simple, rapid high-performance liquid chromatography method has been devised in order to separate and quantify the xanthophylls capsorubin and capasanthin present in red pepper (Capsicum annuum L.) fruits and preparations made from them (paprika and oleoresin). A reversed-phase isocratic non-aqueous system allows the separation of xanthophylls within a few minutes, with detection at 450 nm, using methyl red as internal standard to locate the various carotenoids and xanthophylls found in plant extracts. The selection of extraction solvents, mild saponification conditions, and chromatographic features is evaluated and discussed. The method is proposed for rapid screening of large plant populations, plant selection, as well as for paprika products and oleoresin, and also for nutrition and quality control studies.

  1. Advances in Proteomics Data Analysis and Display Using an Accurate Mass and Time Tag Approach

    PubMed Central

    Zimmer, Jennifer S.D.; Monroe, Matthew E.; Qian, Wei-Jun; Smith, Richard D.

    2007-01-01

    Proteomics has recently demonstrated utility in understanding cellular processes on the molecular level as a component of systems biology approaches and for identifying potential biomarkers of various disease states. The large amount of data generated by utilizing high efficiency (e.g., chromatographic) separations coupled to high mass accuracy mass spectrometry for high-throughput proteomics analyses presents challenges related to data processing, analysis, and display. This review focuses on recent advances in nanoLC-FTICR-MS-based proteomics approaches and the accompanying data processing tools that have been developed to display and interpret the large volumes of data being produced. PMID:16429408

  2. Applications of the solvation parameter model in reversed-phase liquid chromatography.

    PubMed

    Poole, Colin F; Lenca, Nicole

    2017-02-24

    The solvation parameter model is widely used to provide insight into the retention mechanism in reversed-phase liquid chromatography, for column characterization, and in the development of surrogate chromatographic models for biopartitioning processes. The properties of the separation system are described by five system constants representing all possible intermolecular interactions for neutral molecules. The general model can be extended to include ions and enantiomers by adding new descriptors to encode the specific properties of these compounds. System maps provide a comprehensive overview of the separation system as a function of mobile phase composition and/or temperature for method development. The solvation parameter model has been applied to gradient elution separations but here theory and practice suggest a cautious approach since the interpretation of system and compound properties derived from its use are approximate. A growing application of the solvation parameter model in reversed-phase liquid chromatography is the screening of surrogate chromatographic systems for estimating biopartitioning properties. Throughout the discussion of the above topics success as well as known and likely deficiencies of the solvation parameter model are described with an emphasis on the role of the heterogeneous properties of the interphase region on the interpretation and understanding of the general retention mechanism in reversed-phase liquid chromatography for porous chemically bonded sorbents. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Chromatographic Techniques for Rare Earth Elements Analysis

    NASA Astrophysics Data System (ADS)

    Chen, Beibei; He, Man; Zhang, Huashan; Jiang, Zucheng; Hu, Bin

    2017-04-01

    The present capability of rare earth element (REE) analysis has been achieved by the development of two instrumental techniques. The efficiency of spectroscopic methods was extraordinarily improved for the detection and determination of REE traces in various materials. On the other hand, the determination of REEs very often depends on the preconcentration and separation of REEs, and chromatographic techniques are very powerful tools for the separation of REEs. By coupling with sensitive detectors, many ambitious analytical tasks can be fulfilled. Liquid chromatography is the most widely used technique. Different combinations of stationary phases and mobile phases could be used in ion exchange chromatography, ion chromatography, ion-pair reverse-phase chromatography and some other techniques. The application of gas chromatography is limited because only volatile compounds of REEs can be separated. Thin-layer and paper chromatography are techniques that cannot be directly coupled with suitable detectors, which limit their applications. For special demands, separations can be performed by capillary electrophoresis, which has very high separation efficiency.

  4. "Imposed" and "inherent" mucosal activity patterns. Their composite representation of olfactory stimuli

    PubMed Central

    1987-01-01

    Both regional differences in mucosal sensitivity and a gas chromatography-like process along the mucosal sheet have been separately proposed in two sets of earlier studies to produce different odorant-dependent activity patterns across the olfactory mucosa. This investigation evaluated, in one study, whether and to what degree these two mechanisms contribute to the generation of these activity patterns. Summated multiunit discharges were simultaneously recorded from lateral (LN) and medial (MN) sites on the bullfrog's olfactory nerve to sample the mucosal activity occurring near the internal and external nares, respectively. Precisely controlled sniffs of four odorants (benzaldehyde, butanol, geraniol, and octane) were drawn through the frog's olfactory sac in both the forward (H1) and reverse (H2) hale directions. By combining the four resulting measurements, LNH1, LNH2, MNH1, and MNH2, in different mathematical expressions, indexes reflecting the relative effects of the chromatographic process, regional sensitivity, and hale direction could be calculated. Most importantly, the chromatographic process and the regional sensitivity differences both contributed significantly to the mucosal activity patterns. However, their relative roles varied markedly among the four odorants, ranging from complete dominance by either one to substantial contributions from each. In general, the more strongly an odorant was sorbed by the mucosa, the greater was the relative effect of the chromatographic process; the weaker the sorption, the greater the relative effect of regional sensitivity. Similarly, the greater an odorant's sorption, the greater was the effect of hale direction. Other stimulus variables (sniff volume, sniff duration, and the number of molecules within the sniff) had marked effects upon the overall size of the response. For strongly sorbed odorants, the effect of increasing volume was positive; for a weakly sorbed odorant, it was negative. The reverse may be true for duration. In contrast, the effect of increasing the number of molecules was uniformly positive for all four odorants. However, there was little evidence that these other stimulus variables had a major influence upon the effects of the chromatographic process and regional sensitivity differences in their generation of mucosal activity patterns. PMID:3500998

  5. Determination of noscapine, hexylresorcinol and anethole in cough lozenges by liquid chromatography.

    PubMed

    Lucangioli, S; Fernández Otero, G; Rodríguez, V; Carducci, C N

    1996-06-01

    A liquid chromatographic method was developed for the simultaneous separation and determination of noscapine hydrochloride, hexylresorcinol and anethole in cough lozenges. Analysis was performed on a phenyl column with phosphate buffer- acetonitrile as mobile phase and the separated components were detected at 282 mm. Recoveries obtained for the analytes were of 94.6% for noscapine hydrochloride, 99.1% for hexylresorcinol and 96.3% for anethole. The values of the relative standard deviation were 0.8% for noscapine hydrochloride, 1.5% for hexylresorcinol and 1.1% for anethole. The analytical method was validated and a system suitability test was accomplished for the chromatographic method.

  6. Gas-liquid chromatography in lunar organic analysis.

    NASA Technical Reports Server (NTRS)

    Gehrke, C. W.

    1972-01-01

    Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

  7. Microminiature gas chromatograph

    DOEpatents

    Yu, Conrad M.

    1996-01-01

    A microminiature gas chromatograph (.mu.GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode.

  8. HPLC SEPARATION OF CHIRAL ORGANOPHOSPHORUS PESTICIDES ON POLYSACCHARIDE CHIRAL STATIONARY PHASES

    EPA Science Inventory

    High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) were obtained on polysaccharide chiral HPLC columns using an alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, dyfonate, fenamiphos, ...

  9. HILIC separation mechanisms of tetracyclines on amino bonded silica column

    USDA-ARS?s Scientific Manuscript database

    Effects of mobile phase variations on the chromatographic separation on amino bonded silica column in hydrophilic interaction chromatography (HILIC) were investigated for four zwitterionic tetracyclines (TCs): oxytetracycline, doxycycline, chlortetracycline and tetracycline. A mixed-mode retention m...

  10. Improved separation with the intermittently pressed tubing of multilayer coil in type-I counter-current chromatography.

    PubMed

    Yang, Yi; Yang, Jiao; Fang, Chen; Wang, Jihui; Gu, Dongyu; Tian, Jing; Ito, Yoichiro

    2018-05-25

    The intermittently pressed tubing was introduced in type-I counter-current chromatographic system as the separation column to improve the separation performance in the present study. The separations were performed with two different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW) and hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acids as test samples, respectively. The chromatographic performance was evaluated in terms of retention of the stationary phase (Sf), theoretical plate (N) and peak resolution (Rs). In general, the type-I planetary motion with the multilayer coil of non-modified standard tubing can yield the best separation at a low revolution speed of 200 rpm with lower flow rate. The present results with intermittently pressed tubing indicated that the performance was also optimal at the revolution speed of 200 rpm where the lower flow rate was more beneficial to retention of stationary phase and resolution. In the moderately hydrophobic two-phase solvent system composed of hexane-ethyl acetate-metanol-0.1 M hydrochloric acid (1:1:1:1, v/v), DNP-amino acids were separated with Rs at 1.67 and 1.47, respectively, with 12.66% of stationary phase retention at a flow rate of 0.25 ml/min. In the polar solvent system composed of 1-butanol-acetic acid-water (4:1:5, v/v), dipeptide samples were resolved with Rs at 2.18 and 18.75% of stationary phase retention at a flow rate of 0.25 ml/min. These results indicate that the present system substantially improves the separation efficiency of type-I counter-current chromatographic system. Published by Elsevier B.V.

  11. Chromatography in Industry

    NASA Astrophysics Data System (ADS)

    Schoenmakers, Peter

    2009-07-01

    This review focuses on the chromatography research that has been carried out within industry or in close cooperation with industry and that has been reported in the scientific literature between 2006 and mid-2008. Companies in the health care sector, such as pharmaceutical and biotechnology companies, are the largest contributors. Industrial research seems to take place in an open environment in cooperation with academia, peer companies, and institutions. Industry appears ready to embrace new technologies as they emerge, but they focus strongly on making chromatography work robustly, reliably, rapidly, and automatically. “Hyphenated” systems that incorporate on-line sample-preparation techniques and mass-spectrometric detection are the rule rather than the exception. Various multidimensional separation methods are finding numerous applications. Strategies aimed at speeding up the development of new chromatographic methods remain the focus of attention. Also, there is a clear trend toward exploring chromatographic methods for parallel processing along with other strategies for high-throughput analysis.

  12. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  13. Fluorescence-correlation spectroscopy study of molecular transport within reversed-phase chromatographic particles compared to planar model surfaces.

    PubMed

    Cooper, Justin; Harris, Joel M

    2014-12-02

    Reversed-phase liquid chromatography (RPLC) is a widely used technique for molecular separations. Stationary-phase materials for RPLC generally consist of porous silica-gel particles functionalized with n-alkane ligands. Understanding motions of molecules within the interior of these particles is important for developing efficient chromatographic materials and separations. To characterize these dynamics, time-resolved spectroscopic methods (photobleach recovery, fluorescence correlation, single-molecule imaging) have been adapted to measure molecular diffusion rates, typically at n-alkane-modified planar silica surfaces, which serve as models of chromatographic interfaces. A question arising from these studies is how dynamics of molecules on a planar surface relate to motions of molecules within the interior of a porous chromatographic particle. In this paper, imaging-fluorescence-correlation spectroscopy is used to measure diffusion rates of a fluorescent probe molecule 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine perchlorate (DiI) within authentic RPLC porous silica particles and compared with its diffusion at a planar C18-modified surface. The results show that surface diffusion on the planar C18 substrate is much faster than the diffusion rate of the probe molecule through a chromatographic particle. Surface diffusion within porous particles, however, is governed by molecular trajectories along the tortuous contours of the interior surface of the particles. By accounting for the greater surface area that a molecule must explore to diffuse macroscopic distances through the particle, the molecular-scale diffusion rates on the two surfaces can be compared, and they are virtually identical. These results provide support for the relevance of surface-diffusion measurements made on planar model surfaces to the dynamic behavior of molecules on the internal surfaces of porous chromatographic particles.

  14. Effects of urban debris material on the extraction chromatographic separation of strontium: Part II: cement and concrete

    DOE PAGES

    McLain, Derek R.; Liu, Christine; Sudowe, Ralf

    2017-11-02

    The majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. However, it is much more likely that an incident involving a radiation dispersal device (RDD) would occur in an urban or metropolitan area. It is unclear if the currently available separation schemes would be effective in such an event. It is therefore important to determine if the current schemes would be adequate, or to find efficient and accurate ways to separate radiological material from urban debris. One important radiological material that could be used inmore » an RDD is 90Sr. Part I of this work investigated the effects steel had on strontium separations, while this work investigates cement and concrete. This research demonstrates that the individual elements present in a cement and concrete sample matrix can give rise to significant interferences with extraction chromatographic separations. In conclusion, solutions of the constituents mixed in representative ratios; however, show fewer problems« less

  15. Effects of urban debris material on the extraction chromatographic separation of strontium: Part II: cement and concrete

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLain, Derek R.; Liu, Christine; Sudowe, Ralf

    The majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. However, it is much more likely that an incident involving a radiation dispersal device (RDD) would occur in an urban or metropolitan area. It is unclear if the currently available separation schemes would be effective in such an event. It is therefore important to determine if the current schemes would be adequate, or to find efficient and accurate ways to separate radiological material from urban debris. One important radiological material that could be used inmore » an RDD is 90Sr. Part I of this work investigated the effects steel had on strontium separations, while this work investigates cement and concrete. This research demonstrates that the individual elements present in a cement and concrete sample matrix can give rise to significant interferences with extraction chromatographic separations. In conclusion, solutions of the constituents mixed in representative ratios; however, show fewer problems« less

  16. Extraction chromatographic separations of tantalum and tungsten from hafnium and complex matrix constituents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snow, Mathew S.; Finck, Martha R.; Carney, Kevin P.

    2017-02-01

    Ta, Hf, and W analyses from complex matrices (including environmental samples) require high purification of these analytes from each other and major/trace matrix constituents, however, current state-of-the-art Ta/Hf/W separations rely on traditional anion exchange approaches that suffer from relatively similar distribution coefficient (Kd) values for these analytes. This work reports assessment of three commercially available extraction chromatographic resins (TEVA, TRU, and UTEVA) for Ta/Hf/W separations. Batch contact studies show differences in Ta/W,Hf Kd values of up to 106, representing an improvement of a factor of 100 and 300 in Ta/Hf and Ta/W Kd values (respectively) over AG1x4 resin. Variations inmore » the Kd values as a function of HCl concentration for TRU resin show that this resin is well suited for Ta/Hf/W separations, with Ta/Hf, Ta/W, and W/Hf Kd value improvements of 10, 200, and 30 (respectively) over AG1x4 resin. Finally, analyses of digested soil samples (NIST 2710a) using TRU resin and tandem TEVA-TRU columns demonstrate the ability to achieve extremely high purification (>99%) of Ta and W from each other and Hf, as well as enabling very high purification of Ta and W from the major and trace elemental constituents present in soils, using a single chromatographic step.« less

  17. Separation of the fatty acids in menhaden oil as methyl esters with a highly polar ionic liquid gas chromatographic column and identification by time of flight mass spectrometry.

    PubMed

    Fardin-Kia, Ali Reza; Delmonte, Pierluigi; Kramer, John K G; Jahreis, Gerhard; Kuhnt, Katrin; Santercole, Viviana; Rader, Jeanne I

    2013-12-01

    The fatty acids contained in marine oils or products are traditionally analyzed by gas chromatography using capillary columns coated with polyethylene glycol phases. Recent reports indicate that 100 % cyanopropyl siloxane phases should also be used when the analyzed samples contain trans fatty acids. We investigated the separation of the fatty acid methyl esters prepared from menhaden oil using the more polar SLB-IL111 (200 m × 0.25 mm) ionic liquid capillary column and the chromatographic conditions previously optimized for the separation of the complex mixture of fatty acid methyl esters prepared from milk fat. Identifications of fatty acids were achieved by applying Ag(+)-HPLC fractionation and GC-TOF/MS analysis in CI(+) mode with isobutane as the ionization reagent. Calculation of equivalent chain lengths confirmed the assignment of double bond positions. This methodology allowed the identification of 125 fatty acids in menhaden oil, including isoprenoid and furanoid fatty acids, and the novel 7-methyl-6-hexadecenoic and 7-methyl-6-octadecenoic fatty acids. The chromatographic conditions applied in this study showed the potential of separating in a single 90-min analysis, among others, the short chain and trans fatty acids contained in dairy products, and the polyunsaturated fatty acids contained in marine products.

  18. Extraction chromatographic separations of tantalum and tungsten from hafnium and complex matrix constituents

    DOE PAGES

    Snow, Mathew S.; Finck, Martha R.; Carney, Kevin P.; ...

    2017-01-08

    Ta, Hf, and W analyses from complex matrices (including environmental samples) require high purification of these analytes from each other and major/trace matrix constituents, but, current state-of-the-art Ta/Hf/W separations rely on traditional anion exchange approaches that suffer from relatively similar distribution coefficient (Kd) values for these analytes. Our work reports assessment of three commercially available extraction chromatographic resins (TEVA, TRU, and UTEVA) for Ta/Hf/W separations. Batch contact studies show differences in Ta/W,Hf Kd values of up to 10 6, representing an improvement of a factor of 100 and 300 in Ta/Hf and Ta/W Kd values (respectively) over AG1x4 resin. Furthermore,more » variations in the Kd values as a function of HCl concentration for TRU resin show that this resin is well suited for Ta/Hf/W separations, with Ta/Hf, Ta/W, and W/Hf Kd value improvements of 10, 200, and 30 (respectively) over AG1x4 resin. Finally, analyses of digested soil samples (NIST 2710a) using TRU resin and tandem TEVA-TRU columns demonstrate the ability to achieve extremely high purification (>99%) of Ta and W from each other and Hf, as well as enabling very high purification of Ta and W from the major and trace elemental constituents present in soils, using a single chromatographic step.« less

  19. SEPARATION OF PLUTONIUM FROM URANIUM AND FISSION PRODUCTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyd, G.E.; Adamson, A.W.; Schubert, J.

    A chromatographic adsorption process is presented for the separation of plutonium from other fission products formed by the irradiation of uranium. The plutonium and the lighter element fission products are adsorbed on a sulfonated phenol-formaldehyde resin bed from a nitric acid solution containing the dissolved uranium. Successive washes of sulfuric, phosphoric, and nitric acids remove the bulk of the fission products, then an eluate of dilute phosphoric and nitric acids removes the remaining plutonium and fission products. The plutonium is selectively removed by passing this solution through zirconium phosphate, from which the plutonium is dissolved with nitric acid. This processmore » provides a convenient and efficient means for isolating plutonium.« less

  20. Physical, chemical, biological, and biotechnological sciences are incomplete without each other

    USDA-ARS?s Scientific Manuscript database

    Chemical analysis and chromatographic techniques could not separate plasma lipoproteins which are now known as cholesterol- containing, heart-disease related macromolecules in human blood. Scientists at the Lawrence Berkeley Laboratory successfully separated plasma lipoproteins using equilibrium den...

  1. QSAR models for prediction of chromatographic behavior of homologous Fab variants.

    PubMed

    Robinson, Julie R; Karkov, Hanne S; Woo, James A; Krogh, Berit O; Cramer, Steven M

    2017-06-01

    While quantitative structure activity relationship (QSAR) models have been employed successfully for the prediction of small model protein chromatographic behavior, there have been few reports to date on the use of this methodology for larger, more complex proteins. Recently our group generated focused libraries of antibody Fab fragment variants with different combinations of surface hydrophobicities and electrostatic potentials, and demonstrated that the unique selectivities of multimodal resins can be exploited to separate these Fab variants. In this work, results from linear salt gradient experiments with these Fabs were employed to develop QSAR models for six chromatographic systems, including multimodal (Capto MMC, Nuvia cPrime, and two novel ligand prototypes), hydrophobic interaction chromatography (HIC; Capto Phenyl), and cation exchange (CEX; CM Sepharose FF) resins. The models utilized newly developed "local descriptors" to quantify changes around point mutations in the Fab libraries as well as novel cluster descriptors recently introduced by our group. Subsequent rounds of feature selection and linearized machine learning algorithms were used to generate robust, well-validated models with high training set correlations (R 2  > 0.70) that were well suited for predicting elution salt concentrations in the various systems. The developed models then were used to predict the retention of a deamidated Fab and isotype variants, with varying success. The results represent the first successful utilization of QSAR for the prediction of chromatographic behavior of complex proteins such as Fab fragments in multimodal chromatographic systems. The framework presented here can be employed to facilitate process development for the purification of biological products from product-related impurities by in silico screening of resin alternatives. Biotechnol. Bioeng. 2017;114: 1231-1240. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Chromatographic separation and continuously referenced, on-line monitoring of creatine kinase isoenzymes by use of an immobilized-enzyme microreactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denton, M.S.; Bostick, W.D.; Dinsmore, S.R.

    1978-08-01

    We describe a new concept in continuously referenced monitoring of the isoenzyme activities of creatine kinase (EC 2.7.3.2) after liquid-chromatographic separation. After separation on a diethylaminoethyl-Sephacel column, the three isoenzymes of creatine kinase undergo a series of coupled enzyme reactions, ultimately resulting in the formation of ultraviolet-detectable NADPH. A major advantage of this detection system is the immobilized-enzyme microreactor (2 x 17 mm), which may be removed and stored refrigerated when not in use. A split-stream configuration allows self-blanking of endogenous ultraviolet-absorbing constituents in authentic sera samples, which would otherwise make definitive diagnosis and quantitation difficult or impossible. This detectionmore » system is applicable to the automated analysis of creatine kinase isoenzymes in the clinical laboratory.« less

  3. Countercurrent Chromatographic Separation of Proteins Using an Eccentric Coiled Column with Synchronous and Nonsynchronous Type-J Planetary Motions

    PubMed Central

    SHINOMIYA, Kazufusa; YOSHIDA, Kazunori; TOKURA, Koji; TSUKIDATE, Etsuhiro; YANAGIDAIRA, Kazuhiro; ITO, Yoichiro

    2015-01-01

    Protein separation was performed using the high-speed counter-current chromatograph (HSCCC) at both synchronous and nonsynchronous type-J planetary motions. The partition efficiency was evaluated with two different column configurations, eccentric coil and toroidal coil, on the separation of a set of stable protein samples including cytochrome C, myoglobin and lysozyme with a polymer phase system composed of 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate. Better peak resolution was obtained by the eccentric coil than by the toroidal coil using either lower or upper phase as the mobile phase. The peak resolution was further improved using the eccentric coil by the nonsynchronous type-J planetary motion with the combination of 1066 rpm of column rotation and 1000 rpm of revolution. PMID:25765276

  4. Countercurrent chromatographic separation of proteins using an eccentric coiled column with synchronous and nonsynchronous type-J planetary motions.

    PubMed

    Shinomiya, Kazufusa; Yoshida, Kazunori; Tokura, Koji; Tsukidate, Etsuhiro; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2015-01-01

    Protein separation was performed using the high-speed countercurrent chromatograph (HSCCC) at both synchronous and nonsynchronous type-J planetary motions. The partition efficiency was evaluated with two different column configurations, eccentric coil and toroidal coil, on the separation of a set of stable protein samples including cytochrome C, myoglobin and lysozyme with a polymer phase system composed of 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate. Better peak resolution was obtained by the eccentric coil than by the toroidal coil using either lower or upper phase as the mobile phase. The peak resolution was further improved using the eccentric coil by the nonsynchronous type-J planetary motion with the combination of 1066 rpm of column rotation and 1000 rpm of revolution.

  5. Simultaneous determination of carbohydrates and simmondsins in jojoba seed meal (Simmondsia chinensis) by gas chromatography.

    PubMed

    Lein, Sabine; Van Boven, Maurits; Holser, Ron; Decuypere, Eddy; Flo, Gerda; Lievens, Sylvia; Cokelaere, Marnix

    2002-11-22

    Separate methods for the analyses of soluble carbohydrates in different plants and simmondsins in jojoba seed meal are described. A reliable gas chromatographic procedure for the simultaneous quantification of D-pinitol, myo-inositoL sucrose, 5-alpha-D-galactopyranosyl-D-pinitol. 2-alpha-D-galactopyranosyl-D-pinitol, simmondsin, 4-demethylsimmondsin, 5-demethylsimmondsin and 4,5-didemethylsimmondsin as trimethylsilyl derivatives in jojoba seed meal has been developed. The study of different extraction mixtures allowed for the quantitative recovery of the 9 analytes by a mixture of methanol-water (80:20, v/v) in the concentration range between 0.1 and 4%. Comparison of the separation parameters on three different capillary stationary phases with MS detection allowed for the choice of the optimal gas chromatographic conditions for baseline separation of the analytes.

  6. Paired-ion chromatography and high performance liquid chromatography of labetalol in feeds.

    PubMed

    Townley, E R; Ross, B

    1980-11-01

    A high performance liquid chromatographic (HPLC) method using reverse phase paired-ion chromatography and ultraviolet detection at 280 nm has been developed to determine labetalol, an alpha and beta adrenoceptor blocking agent, in Purina No. 5001 rodent chow. The method is simple and rapid, and demonstrates a separation technique applicable to other acidic and basic drugs. It requires only extraction of the drug with methanol--water--acetic acid (66 + 33 + 1) and separation of insoluble material by filtration before HPLC. Labetalol, is chromatographically separated from soluble feed components by means of a microBondapak C18 column and methanol--water--acetic acid (66 + 33 + 1) mobile phase, 0.005M with respect to sodium dioctylsulfosuccinate paired-ion reagent. Average recovery is 98.7% with a relative standard deviation of +/- 2.3% for the equipment described.

  7. Quantitative interference by cysteine and N-acetylcysteine metabolites during the LC-MS/MS bioanalysis of a small molecule.

    PubMed

    Barricklow, Jason; Ryder, Tim F; Furlong, Michael T

    2009-08-01

    During LC-MS/MS quantification of a small molecule in human urine samples from a clinical study, an unexpected peak was observed to nearly co-elute with the analyte of interest in many study samples. Improved chromatographic resolution revealed the presence of at least 3 non-analyte peaks, which were identified as cysteine metabolites and N-acetyl (mercapturic acid) derivatives thereof. These metabolites produced artifact responses in the parent compound MRM channel due to decomposition in the ionization source of the mass spectrometer. Quantitative comparison of the analyte concentrations in study samples using the original chromatographic method and the improved chromatographic separation method demonstrated that the original method substantially over-estimated the analyte concentration in many cases. The substitution of electrospray ionization (ESI) for atmospheric pressure chemical ionization (APCI) nearly eliminated the source instability of these metabolites, which would have mitigated their interference in the quantification of the analyte, even without chromatographic separation. These results 1) demonstrate the potential for thiol metabolite interferences during the quantification of small molecules in pharmacokinetic samples, and 2) underscore the need to carefully evaluate LC-MS/MS methods for molecules that can undergo metabolism to thiol adducts to ensure that they are not susceptible to such interferences during quantification.

  8. Core-Shell in Liquid Chromatography: Application for Determining Sulphonamides in Feed and Meat Using Conventional Chromatographic Systems

    PubMed Central

    Armentano, Antonio; Summa, Simona; Magro, Sonia Lo; D’Antini, Pasquale; Palermo, Carmen; Muscarella, Marilena

    2016-01-01

    A C18 column packed with core-shell particles was used for the chromatographic separation of sulphonamides in feed and meat by a conventional high performance liquid chromatography system coupled with a diode array detector. Two analytical methods, already used in our laboratory, have been modified without any changes in the extraction and clean-up steps and in the liquid chromatography instrumentation. Chromatographic conditions applied on a traditional 5-µm column have been optimized on a column packed with 2.6 µm core-shell particles. A binary mobile phase [acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50: 50 (v/v)] was employed in gradient mode at the flow rate of 1.2 mL with an injection volume of 6 µL. These chromatographic conditions allow the separation of 13 sulphonamides with an entire run of 13 minutes. Preliminary studies have been carried out comparing blanks and spiked samples of feed and meat. A good resolution and the absence of interferences were achieved in chromatograms for both matrices. Since no change was made to the sample preparation, the optimized method does not require a complete revalidation and can be used to make routine analysis faster. PMID:28217560

  9. Chromatographic separation of the platinum-group elements, gold, base metals and sulfur during degassing of a compacting and solidifying igneous crystal pile

    NASA Astrophysics Data System (ADS)

    Boudreau, A. E.; Meurer, W. P.

    The major platinum-group elements (PGE) concentrations in layered intrusions are typically associated with zones in which the sulfide abundance begins to increase. In a number of layered intrusions, there is also a distinct stratigraphic separation in the peak concentrations of the PGE from those of the base metals, gold and sulfur through these zones. These stratigraphic ``offsets'' are characterized by a lower, typically S-poor, Pt- and Pd-enriched zone overlain by a zone enriched in the base metals, S and Au. The separations amount to a few decimeters to several tens of meters. In some instances, the high Pt and Pd concentrations are associated with trivial amounts of sulfide. Theoretical considerations suggest that these offsets can be modeled as chromatographic peaks that develop during an infiltration/reaction process. Using Pd as a typical PGE and Cu as a typical base metal, a numeric model is developed that illustrates how metal separations can develop in a vapor-refining zone as fluid evolved during solidification of a cumulus pile leaches sulfide and redeposits it higher in the crystal pile. The solidification/degassing ore-element transport is coupled with a compaction model for the crystal pile. Solidification resulting from conductive cooling through the base of the compacting column leads to an increasing volatile concentration in the intercumulus liquid until it reaches fluid saturation. Separation and upward migration of this fluid lead to an upward-migrating zone of increasingly higher bulk water contents as water degassed from underlying cumulates enriches overlying, fluid-undersaturated interstitial liquids. Sulfide is resorbed from the degassing regions and is reprecipitated in these vapor-undersaturated interstitial liquids, producing a zone of relatively high modal sulfide that also migrates upward with time. Owing to its strong preference for sulfide, Pd is not significantly mobile until all sulfide is resorbed. The result is a zone of increasing PGE enrichment that follows the sulfide resorption front as solidification/degassing continues. In detail, the highest Pd concentrations occur stratigraphically below the peak in S and base metals. The high Pd/S ratio mimics values conventionally interpreted as the result of high (silicate liquid)/(sulfide liquid) mass ratios (``R'' values). However, in this case, the high Pd/S ratio is the result of a chromatographic/reaction front enrichment and not a magmatic sulfide-saturation event.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ying

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were ablemore » to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic resolution, high column stability, and high sensitivity. In addition, this method showed potential usefulness for the sensitive and quick analysis of hydrolysis products of polysaccharides, and for trace level analysis of individual oligosaccharides or oligosaccharide isomers from biological systems.« less

  11. A Novel High Performance Liquid Chromatographic Method for Simultaneous Determination of Ceftriaxone and Sulbactam in Sulbactomax

    PubMed Central

    Shrivastava, Sanjay Mohan; Singh, Rajkumar; Tariq, Abu; Siddiqui, Masoom Raza; Yadav, Jitendar; Negi, P. S.; Chaudhary, Manu

    2009-01-01

    An isocratic liquid chromatographic method with UV detection at 220 nm is described for simultaneous determination of ceftriaxone sodium and sulbactam sodium in Sulbactomax. Chromatographic separation of two drugs was achieved on a Hypersil ODS C-18 column using a mobile phase consisting of a binary mixture of acetonitrile and tetrabutyl ammonium hydroxide adjusted to pH7.0 with orthophosphoric acid in ratio 70:30. The developed Liquid Chromatographic method offers symmetric peak shape, good resolution and reasonable retention time for both drugs. Linearity, accuracy and precision were found to be acceptable over the concentration range of 125-750 ppm for ceftriaxone sodium and 62.5-375 ppm for sulbactam sodium. The LC method can be used for the quality control of formulated products containing ceftriaxone and sulbactam. PMID:23675112

  12. Chromatographic peak deconvolution of constitutional isomers by multiple-reaction-monitoring mass spectrometry.

    PubMed

    Trapp, Oliver

    2010-02-12

    Highly efficient and sophisticated separation techniques are available to analyze complex compound mixtures with superior sensitivities and selectivities often enhanced by a 2nd dimension, e.g. a separation technique or spectroscopic and spectrometric techniques. For enantioselective separations numerous chiral stationary phases (CSPs) exist to cover a broad range of chiral compounds. Despite these advances enantioselective separations can become very challenging for mixtures of stereolabile constitutional isomers, because the on-column interconversion can lead to completely overlapping peak profiles. Typically, multidimensional separation techniques, e.g. multidimensional GC (MDGC), using an achiral 1st separation dimension and transferring selected analytes to a chiral 2nd separation are the method of choice to approach such problems. However, this procedure is very time consuming and only predefined sections of peaks can be transferred by column switching to the second dimension. Here we demonstrate for stereolabile 1,2-dialkylated diaziridines a technique to experimentally deconvolute overlapping gas chromatographic elution profiles of constitutional isomers based on multiple-reaction-monitoring MS (MRM-MS). The here presented technique takes advantage of different fragmentation probabilities and pathways to isolate the elution profile of configurational isomers. Copyright 2009 Elsevier B.V. All rights reserved.

  13. Microminiature gas chromatograph

    DOEpatents

    Yu, C.M.

    1996-12-10

    A microminiature gas chromatograph ({mu}GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode. 7 figs.

  14. A charge-polarized porous metal-organic framework for gas chromatographic separation of alcohols from water.

    PubMed

    Sun, Jian-Ke; Ji, Min; Chen, Cheng; Wang, Wu-Gen; Wang, Peng; Chen, Rui-Ping; Zhang, Jie

    2013-02-25

    A bipyridinium ligand with a charge separated skeleton has been introduced into a metal-organic framework to yield a porous material with charge-polarized pore space, which exhibits selective adsorption for polar guest molecules and can be further used in gas chromatography for the separation of alcohol-water mixtures.

  15. Synthesis and evaluation of a maltose-bonded silica gel stationary phase for hydrophilic interaction chromatography and its application in Ginkgo Biloba extract separation in two-dimensional systems.

    PubMed

    Sheng, Qianying; Yang, Kaiya; Ke, Yanxiong; Liang, Xinmiao; Lan, Minbo

    2016-09-01

    Maltose covalently bonded to silica was prepared by using carbonyl diimidazole as a cross-linker and employed as a stationary phase for hydrophilic interaction liquid chromatography. The column efficiency and the effect of water content, buffer concentration, and pH value influenced on retention were investigated. The separation or enrichment selectivity was also studied with nucleosides, saccharides, amino acids, peptides, and glycopeptides. The results indicated that the stationary phase processed good separation efficiency and separation selectivity in hydrophilic interaction liquid chromatography mode. Moreover, a two-dimensional hydrophilic interaction liquid chromatography× reversed-phase liquid chromatography method with high orthogonality was developed to analyze the Ginkgo Biloba extract fractions. The development of this two-dimensional chromatographic system would be an effective tool for the separation of complex samples of different polarities and contents. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Continuous separation of copper ions from a mixture of heavy metal ions using a three-zone carousel process packed with metal ion-imprinted polymer.

    PubMed

    Jo, Se-Hee; Lee, See-Young; Park, Kyeong-Mok; Yi, Sung Chul; Kim, Dukjoon; Mun, Sungyong

    2010-11-05

    In this study, a three-zone carousel process based on a proper molecular imprinted polymer (MIP) resin was developed for continuous separation of Cu(2+) from Mn(2+) and Co(2+). For this task, the Cu (II)-imprinted polymer (Cu-MIP) resin was synthesized first and used to pack the chromatographic columns of a three-zone carousel process. Prior to the experiment of the carousel process based on the Cu-MIP resin (MIP-carousel process), a series of single-column experiments were performed to estimate the intrinsic parameters of the three heavy metal ions and to find out the appropriate conditions of regeneration and re-equilibration. The results from these single-column experiments and the additional computer simulations were then used for determination of the operating parameters of the MIP-carousel process under consideration. Based on the determined operating parameters, the MIP-carousel experiments were carried out. It was confirmed from the experimental results that the proposed MIP-carousel process was markedly effective in separating Cu(2+) from Mn(2+) and Co(2+) in a continuous mode with high purity and a relatively small loss. Thus, the MIP-carousel process developed in this study deserves sufficient attention in materials processing industries or metal-related industries, where the selective separation of heavy metal ions with the same charge has been a major concern. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. High-speed and high-resolution UPLC separation at zero degrees Celsius

    PubMed Central

    Wales, Thomas E.; Fadgen, Keith E.; Gerhardt, Geoff C.; Engen, John R.

    2008-01-01

    The conformational properties of proteins can be probed with hydrogen/deuterium exchange mass spectrometry (HXMS). In order to maintain the deuterium label during LC/MS analyses, chromatographic separation must be done rapidly (usually in under 8–10 minutes) and at zero degrees Celsius. Traditional RP-HPLC with ~3 micron particles has shown generally poor chromatographic performance under these conditions and thereby has been prohibitive for HXMS analyses of larger proteins and many protein complexes. Ultra performance liquid chromatography (UPLC) employs particles smaller than 2 microns in diameter to achieve superior resolution, speed, and sensitivity as compared to HPLC. UPLC has previously been shown to be compatible with the fast separation and low temperature requirements of HXMS. Here we present construction and validation of a custom UPLC system for HXMS. The system is based on the Waters nanoACQUITY platform and contains a Peltier-cooled module that houses the injection and switching valves, online pepsin digestion column, and C-18 analytical separation column. Single proteins in excess of 95 kDa and a four-protein mixture in excess of 250 kDa have been used to validate the performance of this new system. Near baseline resolution was achieved in 6 minute separations at 0 °C and displayed a median chromatographic peak width of ~2.7 sec at half height. Deuterium recovery was similar to that obtained using a conventional HPLC and icebath. This new system represents a significant advancement in HXMS technology that is expected to make the technique more accessible and mainstream in the near future. PMID:18672890

  18. Effect of Coriolis force on counter-current chromatographic separation by centrifugal partition chromatography.

    PubMed

    Ikehata, Jun-Ichi; Shinomiya, Kazufusa; Kobayashi, Koji; Ohshima, Hisashi; Kitanaka, Susumu; Ito, Yoichiro

    2004-02-06

    The effect of Coriolis force on the counter-current chromatographic separation was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile (ACN); tert-butyl methyl ether (MtBE)-aqueous 0.1% trifluoroacetic acid (TFA) (1:1); MtBE-ACN-aqueous 0.1% TFA (2:2:3); and 12.5% (w/w) polyethylene glycol (PEG) 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise (CW) and counterclockwise column rotation. Better partition efficiencies were attained by the CW rotation in both mobile phases in all the two-phase solvent systems examined. The mathematical analysis also revealed the Coriolis force works favorably under the CW column rotation for both mobile phases. The overall results demonstrated that the Coriolis force produces substantial effects on CPC separation in both organic-aqueous and aqueous-aqueous two-phase systems.

  19. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    PubMed

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Comprehensive two-dimensional chromatography with coupling of reversed phase high performance liquid chromatography and supercritical fluid chromatography.

    PubMed

    Stevenson, Paul G; Tarafder, Abhijit; Guiochon, Georges

    2012-01-13

    A 2D comprehensive chromatographic separation of blackberry sage fragrant oil was performed by using HPLC in the first dimension and SFC in the second. A C(18)-bonded silica column eluted with an ACN gradient was used in the HPLC dimension and an amino-bonded silica column eluted with ACN as a modifier in the SFC dimension. This 2D separation was completed in the off-line mode, the fractions from the HPLC column being collected and injected in the SFC column. The retention factors on the two columns have a -0.757 correlation coefficient. The method provides a practical peak capacity of 2400 in 280 min. The first eluted peaks in HPLC are the last ones eluted in SFC and vice versa. The results demonstrate that the coupling of an HPLC and an SFC separation have a great potential for 2D chromatographic separations. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Polymethacrylate-based monoliths as stationary phases for separation of biopolymers and immobilization of enzymes.

    PubMed

    Martinović, Tamara; Josić, Djuro

    2017-11-01

    The experiences in the production and application of polymethacrylate-based monolithic supports, since their development almost thirty years ago, are presented. The main driving force for the development of new chromatographic supports was the necessity for the isolation and separation of physiologically active biopolymers and their use for therapeutic purposes. For this sake, a development of a method for fast separation, preventing denaturation and preserving their biological activity was necessary. Development of polysaccharide-based supports, followed by the introduction of polymer-based chromatographic media, is shortly described. This development was followed by the advances in monolithic media that are now used for both large- and small-scale separation of biopolymers and nanoparticles. Finally, a short overview is given about the applications of monoliths for sample displacement chromatography, resulting in isolation of physiologically active biomolecules, such as proteins, protein complexes, and nucleic acid, as well as high-throughput sample preparation for proteomic investigations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Development of High Precision Metal Micro-Electro-Mechanical-Systems Column for Portable Surface Acoustic Wave Gas Chromatograph

    NASA Astrophysics Data System (ADS)

    Iwaya, Takamitsu; Akao, Shingo; Sakamoto, Toshihiro; Tsuji, Toshihiro; Nakaso, Noritaka; Yamanaka, Kazushi

    2012-07-01

    In the field of environmental measurement and security, a portable gas chromatograph (GC) is required for the on-site analysis of multiple hazardous gases. Although the gas separation column has been downsized using micro-electro-mechanical-systems (MEMS) technology, an MEMS column made of silicon and glass still does not have sufficient robustness and a sufficiently low fabrication cost for a portable GC. In this study, we fabricated a robust and inexpensive high-precision metal MEMS column by combining diffusion-bonded etched stainless-steel plates with alignment evaluation using acoustic microscopy. The separation performance was evaluated using a desktop GC with a flame ionization detector and we achieved the high separation performance comparable to the best silicon MEMS column fabricated using a dynamic coating method. As an application, we fabricated a palm-size surface acoustic wave (SAW) GC combining this column with a ball SAW sensor and succeeded in separating and detecting a mixture of volatile organic compounds.

  3. Separation of sunscreens in skincare creams using greener high-temperature liquid chromatography and subcritical water chromatography.

    PubMed

    Kapalavavi, B; Marple, R; Gamsky, C; Yang, Y

    2012-04-01

    In this study, high-temperature liquid chromatographic (HTLC) and subcritical water chromatographic (SBWC) separations of sunscreens contained in skincare creams were achieved at temperatures ranging from 90 to 250°C. The columns employed in this work include a ZirChrom-DiamondBond-C18, a XTerra MS C18 and a XBridge C18 column. The quantity of methanol consumed by the greener HTLC sunscreen methods developed in this project is significantly reduced although the HTLC separation at this stage is not as efficient as that achieved by traditional HPLC. SBWC separation of sunscreens was also achieved on the XTerra MS C18 and the XBridge C18 columns using pure water at 230-250°C. Methanol was eliminated in the SBWC methods developed in this study. © 2011 The Authors. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  4. Enantioseparation of racemic aminoglutethimide using asynchronous simulated moving bed chromatography.

    PubMed

    Lin, Xiaojian; Gong, Rujin; Li, Jiaxu; Li, Ping; Yu, Jianguo; Rodrigues, Alirio E

    2016-10-07

    The separation of aminoglutethimide enantiomers by the continuous multicolumn chromatographic processes were investigated experimentally and theoretically, where the columns were packed with cellulose tris 3,5-dimethylphenyl-carbamate stationary phase (brand name Chiralcel OD) and mobile phase was a mixture of n-hexane and ethanol with monoethanolamine additive. The continuous enantioseparation processes included a synchronous shifting process (SMB) and an asynchronous shifting process (VARICOL), which allowed reducing the column number (here from six-column SMB to five-column VARICOL process). Transport-dispersive model with the consideration of both intraparticle mass transfer resistance and axial dispersion was adopted to design and optimize the operation conditions for the separation of aminoglutethimide enantiomers by SMB process and VARICOL process. According to the optimized operation conditions, experiments were carried out on VARICOL-Micro unit using five-column VARICOL process with 1/1.5/1.5/1 configuration and six-column SMB process with 1/2/2/1 configuration. Products of R-aminoglutethimide (R-AG) enantiomer and S-aminoglutethimide (S-AG) enantiomer with more than 99.0% purity were obtained continuously from extract stream and raffinate stream, respectively. Furthermore, the experiemntal data obtained from five-column VARICOL process were compared with that from six-column SMB process, the feasibility and efficiency for the separation of guaifenesin enantiomers by VARICOL processes were evaluated. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Layer-by-layer self-assembled graphene oxide/silica microsphere composites as stationary phase for high performance liquid chromatography.

    PubMed

    Liang, Xiaojing; Liu, Shujuan; Song, Xinwang; Zhu, Yangwen; Jiang, Shengxiang

    2012-11-21

    Graphene oxide (GO) has been layer-by-layer assembled onto silica microspheres to form a GO/SiO(2) composite stationary phase. All the characterizations of GO/SiO(2) by elemental analysis, Raman spectroscopy and Fourier transformed infrared spectrometry confirmed that with the increase of the assembled layer, GO gradually increases on the silica surface. The chromatographic properties of bare SiO(2) and GO/SiO(2) with different GO assembled layers show that the amount of GO plays an important role in the separation of analytes. Only the appropriate amount of GO on SiO(2) can perform a good chromatographic separation. The comparison between chromatographic performances of bare SiO(2) column, GO/SiO(2)-2 column and C18 commercial column clearly show that GO/SiO(2)-2 and C18 columns obtained a better separation; GO/SiO(2)-2 exhibits a large π-electron system and C18 exhibits hydrophobicity. The eluting order, peak width and resolution of analyte on GO/SiO(2)-2 column was highly dependent on the size of its π-electron system, while on the C18 column the decisive factor is its hydrophobic property.

  6. Dried calcium alginate/magnetite spheres: a new support for chromatographic separations and enzyme immobilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burns, M.A.; Kvesitadze, G.I.; Graves, D.J.

    1985-02-01

    Dried spheres made from an alginate solution containing magnetite particles have excellent potential as a support for enzyme immobilization and chromatographic applications. The beads were found to be much stronger than gels such as polyacrylamide and dextran, indicating that high flow rates and pressures could be used in column separations. The support withstood not only temperatures of up to 120/sup 0/C, but also most pH values and common solvents. While some solutions, such as phosphate buffers, dissolved the spheres, stabilization with Tyzor TE eliminated this problem. The physical properties of the beads include a glasslike density of 2.2 g/mL, excellentmore » sphericity, low porosity, and a narrow size distribution. The magnetite present in the support allows the beads to be used for magnetic separations such as high gradient magnetic filtration. Their high degree of microroughness provides a large exposed surface area for enzyme and ligand binding. Mixed Actinomyces fradiae proteases and Aspergillus niger ..cap alpha..-amylase, two enzymes representative of classes which attack large substrates, were immobilized on the bead's surface with high activity and stability. A cyanuric dye which can be used in chromatographic applications (Cibacron Blue F3GA) was also readily coupled to the surface of this support with good yield.« less

  7. Improving LC-MS sensitivity through increases in chromatographic performance: comparisons of UPLC-ES/MS/MS to HPLC-ES/MS/MS.

    PubMed

    Churchwell, Mona I; Twaddle, Nathan C; Meeker, Larry R; Doerge, Daniel R

    2005-10-25

    Recent technological advances have made available reverse phase chromatographic media with a 1.7 microm particle size along with a liquid handling system that can operate such columns at much higher pressures. This technology, termed ultra performance liquid chromatography (UPLC), offers significant theoretical advantages in resolution, speed, and sensitivity for analytical determinations, particularly when coupled with mass spectrometers capable of high-speed acquisitions. This paper explores the differences in LC-MS performance by conducting a side-by-side comparison of UPLC for several methods previously optimized for HPLC-based separation and quantification of multiple analytes with maximum throughput. In general, UPLC produced significant improvements in method sensitivity, speed, and resolution. Sensitivity increases with UPLC, which were found to be analyte-dependent, were as large as 10-fold and improvements in method speed were as large as 5-fold under conditions of comparable peak separations. Improvements in chromatographic resolution with UPLC were apparent from generally narrower peak widths and from a separation of diastereomers not possible using HPLC. Overall, the improvements in LC-MS method sensitivity, speed, and resolution provided by UPLC show that further advances can be made in analytical methodology to add significant value to hypothesis-driven research.

  8. Multidimensional profiling of components in complex mixtures of natural products for metabolic analysis, proof of concept: application to Quillaja saponins.

    PubMed

    Bankefors, Johan; Nord, Lars I; Kenne, Lennart

    2010-02-01

    A method for separation and detection of major and minor components in complex mixtures has been developed, utilising two-dimensional high-performance liquid chromatography (2D-HPLC) combined with electrospray ionisation ion-trap multiple-stage mass spectrometry (ESI-ITMS(n)). Chromatographic conditions were matched with mass spectrometric detection to maximise the number of components that could be separated. The described procedure has proven useful to discern several hundreds of saponin components when applied to Quillaja saponaria Molina bark extracts. The discrimination of each saponin component relies on the fact that three coordinates (x, y, z) for each component can be derived from the retention time of the two chromatographic steps (x, y) and the m/z-values from the multiple-stage mass spectrometry (z(n), n=1, 2, ...). Thus an improved graphical representation was obtained by combining retention times from the two-stage separation with +MS(1) (z(1)) and the additional structural information from the second mass stage +MS(2) (z(2), z(3)) corresponding to the main fragment ions. By this approach three-dimensional plots can be made that reveal both the chromatographic and structural properties of a specific mixture which can be useful in fingerprinting of complex mixtures. 2009 Elsevier B.V. All rights reserved.

  9. Evaluation of chromatographic columns packed with semi- and fully porous particles for benzimidazoles separation.

    PubMed

    Gonzalo-Lumbreras, Raquel; Sanz-Landaluze, Jon; Cámara, Carmen

    2015-07-01

    The behavior of 15 benzimidazoles, including their main metabolites, using several C18 columns with standard or narrow-bore diameters and different particle size and type were evaluated. These commercial columns were selected because their differences could affect separation of benzimidazoles, and so they can be used as alternative columns. A simple screening method for the analysis of benzimidazole residues and their main metabolites was developed. First, the separation of benzimidazoles was optimized using a Kinetex C18 column; later, analytical performances of other columns using the above optimized conditions were compared and then individually re-optimized. Critical pairs resolution, analysis run time, column type and characteristics, and selectivity were considered for chromatographic columns comparison. Kinetex XB was selected because it provides the shortest analysis time and the best resolution of critical pairs. Using this column, the separation conditions were re-optimized using a factorial design. Separations obtained with the different columns tested can be applied to the analysis of specific benzimidazoles residues or other applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Separative analyses of a chromatographic column packed with a core-shell adsorbent for lithium isotope separation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugiyama, T.; Sugura, K.; Enokida, Y.

    2015-03-15

    Lithium-6 is used as a blanket material for sufficient tritium production in DT fueled fusion reactors. A core-shell type adsorbent was proposed for lithium isotope separation by chromatography. The mass transfer model in a chromatographic column consisted of 4 steps, such as convection and dispersion in the column, transfer through liquid films, intra-particle diffusion and and adsorption or desorption at the local adsorption sites. A model was developed and concentration profiles and time variation in the column were numerically simulated. It became clear that core-shell type adsorbents with thin porous shell were saturated rapidly relatively to fully porous one andmore » established a sharp edge of adsorption band. This is very important feature because lithium isotope separation requires long-distance development of adsorption band. The values of HETP (Height Equivalent of a Theoretical Plate) for core-shell adsorbent packed column were estimated by statistical moments of the step response curve. The value of HETP decreased with the thickness of the porous shell. A core-shell type adsorbent is, then, useful for lithium isotope separation. (authors)« less

  11. Liquid chromatographic separation and thermodynamic investigation of lorcaserin hydrochloride enantiomers on immobilized amylose-based chiral stationary phase.

    PubMed

    Wani, Dattatraya V; Rane, Vipul P; Mokale, Santosh N

    2018-03-01

    A novel liquid chromatographic method was developed for enantiomeric separation of lorcaserin hydrochloride on Chiralpak IA column containing chiral stationary phase immobilized with amylose tris (3.5-dimethylphenylcarbamate) as chiral selector. Baseline separation with resolution greater than 4 was achieved using mobile phase containing mixture of n-hexane/ethanol/methanol/diethylamine (95:2.5:2.5:0.1, v/v/v/v) at a flow rate of 1.2 mL/min. The limit of detection and limit of quantification of the S-enantiomer were found to be 0.45 and 1.5 μg/mL, respectively; the developed method was validated as per ICH guideline. The influence of column oven temperatures studied in the range of 20°C to 50°C on separation was studied; from this, retention, separation, and resolution were investigated. The thermodynamic parameters ΔH°, ΔS°, and ΔG° were evaluated from van't Hoff plots,(Ink' versus 1/T) and used to explain the strength of interaction between enantiomers and immobilized amylose-based chiral stationary phase. © 2017 Wiley Periodicals, Inc.

  12. Synthesis and radiometric evaluation of diglycolamide functionalized mesoporous silica for the chromatographic separation of actinides Th, Pa and U.

    PubMed

    Hopkins, Philip D; Mastren, Tara; Florek, Justyna; Copping, Roy; Brugh, Mark; John, Kevin D; Nortier, Meiring F; Birnbaum, Eva R; Kleitz, Freddy; Fassbender, Michael E

    2018-04-17

    The separation of Th, Pa, and U is of high importance in many applications including nuclear power, nuclear waste, environmental and geochemistry, nuclear forensics and nuclear medicine. Diglycolamide (DGA)-based resins have shown the ability to separate many elements, however, these resins consist of non-covalent impregnation of the DGA molecules on the resin backbone resulting in co-elution of the extraction molecule during separation cycles, therefore limiting their long-term and repeated use. Covalently binding the DGA molecules onto silica is one way to overcome this issue. Herein, measured equilibrium distribution coefficients of normal extraction chromatographic DGA resin and a covalently bound form (KIT-6-N-DGA sorbent) are reported. Several differences are observed between the two systems, the most significant being observed for uranium, which demonstrated significantly lower sorption behavior on KIT-6-N-DGA. These results indicate that U can effectively be separated from Th and Pa using KIT-6-N-DGA, a task that could not be completed with the use of normal DGA alone.

  13. Single-step preparation of selected biological fluids for the high performance liquid chromatographic analysis of fat-soluble vitamins and antioxidants.

    PubMed

    Lazzarino, Giacomo; Longo, Salvatore; Amorini, Angela Maria; Di Pietro, Valentina; D'Urso, Serafina; Lazzarino, Giuseppe; Belli, Antonio; Tavazzi, Barbara

    2017-12-08

    Fat-soluble vitamins and antioxidants are of relevance in health and disease. Current methods to extract these compounds from biological fluids mainly need use of multi-steps and multi organic solvents. They are time-consuming and difficult to apply to treat simultaneously large sample number. We here describe a single-step, one solvent extraction of fat-soluble vitamins and antioxidants from biological fluids, and the chromatographic separation of all-trans-retinoic acid, 25-hydroxycholecalciferol, all-trans-retinol, astaxanthin, lutein, zeaxanthin, trans-β-apo-8'-carotenal, γ-tocopherol, β-cryptoxanthin, α-tocopherol, phylloquinone, lycopene, α-carotene, β-carotene and coenzyme Q 10 . Extraction is obtained by adding one volume of biological fluid to two acetonitrile volumes, vortexing for 60s and incubating for 60min at 37°C under agitation. HPLC separation occurs in 30min using Hypersil C18, 100×4.6mm, 5μm particle size column, gradient from 70% methanol+30% H 2 O to 100% acetonitrile, flow rate of 1.0ml/min and 37°C column temperature. Compounds are revealed using highly sensitive UV-VIS diode array detector. The HPLC method suitability was assessed in terms of sensitivity, reproducibility and recovery. Using the present extraction and chromatographic conditions we obtained values of the fat-soluble vitamins and antioxidants in serum from 50 healthy controls similar to those found in literature. Additionally, the profile of these compounds was also measured in seminal plasma from 20 healthy fertile donors. Results indicate that this simple, rapid and low cost sample processing is suitable to extract fat-soluble vitamins and antioxidants from biological fluids and can be applied in clinical and nutritional studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Multidimensional High-Resolution Gas Chromatographic Investigations of Hydrocarbon Fuels and Various Turbine Engine Fuel Precursors.

    DTIC Science & Technology

    1985-08-01

    time were spurious transits observed during the recording of the chromatographic output data. *Packaged gas purification filters supplied by Alltech ... Alltech ) that were needed for these unusual installations. When the column diameters were small and of comparable size, the assembly attach- ments at...into an MDGC system has definite advantages as separations can be made faster and with greater detectability. However, specific precautions must be

  15. Binding of [51Cr]ethylenediaminetetraacetate to proteins of human plasma.

    PubMed Central

    Babiker, M M

    1986-01-01

    Binding of [51Cr]EDTA to human plasma proteins was investigated using chemical and chromatographic techniques of separation of the proteins and protein fractions. Total plasma proteins isolated with ethanol retained 12.95 +/- 0.46% of the initial plasma activity. Proteins separated by other precipitants retained about 16% of the initial radioactivity. Globulins exhibited the highest binding capacity for [51Cr]EDTA and retained about 11.7% of the initial plasma activity following chromatographic separation. This value represents about 70% of the radioactivity bound by the total proteins of the plasma. gamma-Globulins contributed most of the binding attributed to the globulins and retained about 8.7% of the initial [51Cr]EDTA activity. The repeatedly reported underestimation of the renal glomerular filtration rate when estimated as the clearance of [51Cr]EDTA could be adequately accounted for by the extent of binding of this marker to the plasma proteins. PMID:2427701

  16. Chromatographic separation and continuously referenced, on-line monitoring of creatine kinase isoenzymes by use of an immobilized-enzyme microreactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denton, M.S.; Bostick, W.D.; Dinsmore, S.R.

    1978-08-01

    We describe a new concept in continuously referenced monitoring of the isoenzyme activities of creatine kinase (EC 2.7.3.2) after liquid-chromatographic separation. After separation on a diethylaminoethyl-Sephacel column, the three isoenzymes of creatine kinase undergo a series of upled enzyme reactions, ultimately resulting in the formation of ultraviolet-detectable NADPH. A major advantage of this detection system is the immobilized-enzyme microreactor (2 x 17 mm), which may be removed and stored refrigerated when not in use. A split-stream configuration allows self-blanking of endogenous ultraviolet-absorbing constituents in authentic sera samples, which would otherwise make definitive diagnosis and quantitation difficult or impossible. This detectionmore » system is applicable to the automated analysis of creatine kinase isoenzymes in the clinical laboratory. 5 figures; 42 references.« less

  17. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    PubMed

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Liquid chromatographic separation of zalcitabine and its stereoisomers.

    PubMed

    Scypinski, S; Ross, A J

    1994-10-01

    A liquid chromatographic method capable of separating and quantitating the stereoisomers of zalcitabine has been developed and validated. The separation was achieved with an Astec Cyclobond I--RSP column and a mobile phase of 0.25% triethylamine in water adjusted to a pH of 6.5 with glacial acetic acid. All enantiomers were found to exhibit a linear response in the range of 0.1-10% in the presence of 100% zalcitabine. Precision of analysis was found to be less than 1.5% at a level of 1% relative to zalcitabine. The limit of detection for two of the three enantiomeric impurities was determined to be 0.05% relative to zalcitabine. The detection limit for the third was found to be 0.1%. This method was successfully applied to the analysis of reference standards and several production scale batches. All of these materials were found to be stereochemically pure to a level of 99.8% or better.

  19. High-performance liquid chromatographic separation of human haemoglobins. Simultaneous quantitation of foetal and glycated haemoglobins.

    PubMed

    Bisse, E; Wieland, H

    1988-12-29

    A high-performance liquid chromatographic system, which uses a weak cation exchanger (PolyCATA) together with Bis-Tris buffer (pH 6.47-7.0) and sodium acetate gradients, is described. Samples from adults and newborns were analysed and a clean separation of many minor and major normal and abnormal haemoglobin (Hb) variants was greatly improved. The method allows the separation of minor foetal haemoglobin (HbF) variants and the simultaneous quantitation of HbF and glycated HbA. HbF values correlated well with those obtained by the alkali denaturation method (r = 0.997). The glycated haemoglobin (HbAIc) levels measured in patients with high HbF concentrations correlated with the total glycated haemoglobin determined by bioaffinity chromatography (r = 0.973). The procedure is useful for diagnostic applications and affords an effective and sensitive way of examining blood samples for haemoglobin abnormalities.

  20. Theory and practical understanding of the migration behavior of proteins and peptides in CE and related techniques.

    PubMed

    Freitag, Ruth; Hilbrig, Frank

    2007-07-01

    CEC is defined as an analytical method, where the analytes are separated on a chromatographic column in the presence of an applied voltage. The separation of charged analytes in CEC is complex, since chromatographic interaction, electroosmosis and electrophoresis contribute to the experimentally observed behavior. The putative contribution of effects such as surface electrodiffusion has been suggested. A sound theoretical treatment incorporating all effects is currently not available. The question of whether the different effects contribute in an independent or an interdependent manner is still under discussion. In this contribution, the state-of-the-art in the theoretical description of the individual contributions as well as models for the retention behavior and in particular possible dimensionless 'retention factors' is discussed, together with the experimental database for the separation of charged analytes, in particular proteins and peptides, by CEC and related techniques.

  1. Nanocapillaries for Open Tubular Chromatographic Separations of Proteins in Femtoliter to Picoliter Samples

    PubMed Central

    Wang, Xiayan; Cheng, Chang; Wang, Shili; Zhao, Meiping; Dasgupta, Purnendu K.; Liu, Shaorong

    2009-01-01

    We have recently examined the potential of bare nanocapillaries for free solution DNA separations and demonstrated efficiencies exceeding 106 theoretical plates/m. In the present work, we demonstrate the use of bare and hydroxypropylcellulose (HPC) coated open tubular nanocapillaries for protein separations. Using 1.5 μm inner diameter (i.d.) capillary columns, hydrodynamically injecting femto to picoliter (fL-pL) volumes of fluorescent or fluorescent dye labeled protein samples, utilizing a pneumatically pressurized chamber containing 1.0 mM sodium tetraborate solution eluent (typ. 200 psi) as the pump and performing on-column detection using a simple laser-induced fluorescence detector, we demonstrate efficiencies of close to a million theoretical plates/m while generating single digit μL volumes of waste for a complete chromatographic run. We achieve baseline resolution for a protein mixture consisting of transferrin, α-lactalbumin, insulin, and α -2-macroglobulin. PMID:19663450

  2. Enhanced capabilities of separation in Sequential Injection Chromatography--fused-core particle column and its comparison with narrow-bore monolithic column.

    PubMed

    Chocholouš, Petr; Kosařová, Lucie; Satínský, Dalibor; Sklenářová, Hana; Solich, Petr

    2011-08-15

    In the Sequential Injection Chromatography (SIC) only monolithic columns for chromatographic separations have been used so far. This article presents the first use of fused-core particle packed column in an attempt to extend of the chromatographic capabilities of the SIC system. A new fused-core particle column (2.7 μm) Ascentis(®) Express C18 (Supelco™ Analytical) 30 mm × 4.6 mm brings high separation efficiency within flow rates and pressures comparable to monolithic column Chromolith(®) Performance RP-18e 100-3 (Merck(®)) 100 mm × 3 mm. Both columns matches the conditions of the commercially produced SIC system - SIChrom™ (8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with 4 mL reservoir - maximal work pressure 1000 PSI) (FIAlab(®), USA). The system was tested by the separation of four estrogens with similar structure and an internal standard - ethylparaben. The mobile phase composed of acetonitrile/water (40/60 (v/v)) was pumped isocratic at flow rate 0.48 mL min(-1). Spectrophotometric detection was performed at wavelength of 225 nm and injected volume of sample solutions was 10 μL. The chromatographic characteristics of both columns were compared. Obtained results and conclusions have shown that both fused-core particle column and longer narrow shaped monolithic column bring benefits into the SIC method. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. HOT ELUENT CAPILLARY LIQUID CHROMATOGRAPHY USING ZIRCONIA AND TITANIA BASED STATIONARY PHASES. (R825344)

    EPA Science Inventory

    Abstract

    High speed capillary liquid chromatographic separations using a simple home made system constructed from readily available inexpensive components have been studied. Using thermally stable zirconia and titania based packing, the separation of eight alkylbenzene...

  4. SEPARATION AND QUANTITATION OF NITROBENZENES AND THEIR REDUCTION PRODUCTS NITROANILINES AND PHENYLENEDIAMINES BY REVERSED=PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    A reversed-phase high-performance liquid chromatographic method for the separation and quantitation of a mixture consisting of nitrobenzene, dinitrobenzene isomers, 1,3,5-trinitrobenzene and their reduction products: aniline, nitroanilines and phenylenediamines has been developed...

  5. Innovative high-performance liquid chromatography method development for the screening of 19 antimalarial drugs based on a generic approach, using design of experiments, independent component analysis and design space.

    PubMed

    Debrus, B; Lebrun, P; Kindenge, J Mbinze; Lecomte, F; Ceccato, A; Caliaro, G; Mbay, J Mavar Tayey; Boulanger, B; Marini, R D; Rozet, E; Hubert, Ph

    2011-08-05

    An innovative methodology based on design of experiments (DoE), independent component analysis (ICA) and design space (DS) was developed in previous works and was tested out with a mixture of 19 antimalarial drugs. This global LC method development methodology (i.e. DoE-ICA-DS) was used to optimize the separation of 19 antimalarial drugs to obtain a screening method. DoE-ICA-DS methodology is fully compliant with the current trend of quality by design. DoE was used to define the set of experiments to model the retention times at the beginning, the apex and the end of each peak. Furthermore, ICA was used to numerically separate coeluting peaks and estimate their unbiased retention times. Gradient time, temperature and pH were selected as the factors of a full factorial design. These retention times were modelled by stepwise multiple linear regressions. A recently introduced critical quality attribute, namely the separation criterion (S), was also used to assess the quality of separations rather than using the resolution. Furthermore, the resulting mathematical models were also studied from a chromatographic point of view to understand and investigate the chromatographic behaviour of each compound. Good adequacies were found between the mathematical models and the expected chromatographic behaviours predicted by chromatographic theory. Finally, focusing at quality risk management, the DS was computed as the multidimensional subspace where the probability for the separation criterion to lie in acceptance limits was higher than a defined quality level. The DS was computed propagating the prediction error from the modelled responses to the quality criterion using Monte Carlo simulations. DoE-ICA-DS allowed encountering optimal operating conditions to obtain a robust screening method for the 19 considered antimalarial drugs in the framework of the fight against counterfeit medicines. Moreover and only on the basis of the same data set, a dedicated method for the determination of three antimalarial compounds in a pharmaceutical formulation was optimized to demonstrate both the efficiency and flexibility of the methodology proposed in the present study. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. [Isolation and purification of recombinant soluble and non-fusion angiogenesis inhibitor Kringle 5 using chromatography].

    PubMed

    Ma, Lina; Wu, Dan; Bian, Liujiao

    2012-08-01

    The Kringle 5 domain of plasminogen is one of the most potent angiogenesis inhibitors known to date, which can inhibit cell proliferation and migration efficiently. In the study, on the foundation of successful clone and expression of recombinant soluble and non-fusion angiogenesis inhibitor Kringle 5, a two-step chromatographic method, including the use of SP Sepharose Fast Flow cation exchanger and Sephacryl S-100 HR size exclusion chromatography in sequence, was established to separate and purify angiogenesis inhibitor Kringle 5. On the SP Sepharose Fast Flow column, the buffer A consisted of 50.0 mmol/L acetic acid-sodium acetate (pH 5.2), and the buffer B consisted of buffer A with the addition of 0.5 mol/L sodium chloride (pH 5.2); on Sephacryl S-100 HR column, the elution buffer was 5.0 mmol/L phosphate solution (pH 7.0). Through the two-step chromatographic purification process, the purity of the obtained Kringle 5 was more than 98%. In addition, it was found that the obtained Kringle 5 could inhibit the blood vessel growth of chick embryo chorioallantoic membrane effectively. Finally it is concluded that this method can effectively separate active recombinant soluble and non-fusion angiogenesis inhibitor Kringle 5.

  7. Characterization of plant polysaccharides from Dendrobium officinale by multiple chromatographic and mass spectrometric techniques.

    PubMed

    Ma, Huiying; Zhang, Keke; Jiang, Qing; Dai, Diya; Li, Hongli; Bi, Wentao; Chen, David Da Yong

    2018-04-27

    Plant polysaccharides have numerous medicinal functions. Due to the differences in their origins, regions of production, and cultivation conditions, the quality and the functions of polysaccharides can vary significantly. They are macromolecules with large molecular weight (MW) and complex structure, and pose great challenge for the analytical technology used. Taking Dendrobium officinale (DO) from various origins and locations as model samples. In this investigation, mechanochemical extraction method was used to successfully extract polysaccharides from DO using water as solvent, the process is simple, fast (40 s) and with high yield. The MWs of the intact saccharides from calibration curve and light scattering measurement were determined and compared after separation with size exclusion chromatography (SEC). The large polysaccharide was acid hydrolyzed to oligosaccharides and the products were efficiently separated and identified using liquid chromatography coupled to a high resolution tandem mass spectrometry (LC-MS 2 ). Obvious differences were observed among LC-MS 2 chromatograms of digested products, and the chemical structures for the products were proposed based on accurate mass values. More importantly, isomeric digested carbohydrate compounds were explored and characterized. All the chromatographic and mass spectrometric results in this study provided a multi-dimensional characterization, fingerprint analysis, and molecular structure level assessment of plant polysaccharides. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. HPLC-PFD determination of priority pollutant PAHs in water, sediment, and semipermeable membrane devices

    USGS Publications Warehouse

    Williamson, K.S.; Petty, J.D.; Huckins, J.N.; Lebo, J.A.; Kaiser, E.M.

    2002-01-01

    High performance liquid chromatography coupled with programmable fluorescence detection was employed for the determination of 15 priority pollutant polycyclic aromatic hydrocarbons (PPPAHs) in water, sediment, and semipermeable membrane devices (SPMDs). Chromatographic separation using this analytical method facilitates selectivity, sensitivity (ppt levels), and can serve as a non-destructive technique for subsequent analysis by other chromatographic and spectroscopic techniques. Extraction and sample cleanup procedures were also developed for water, sediment, and SPMDs using various chromatographic and wet chemical methods. The focus of this publication is to examine the enrichment techniques and the analytical methodologies used in the isolation, characterization, and quantitation of 15 PPPAHs in different sample matrices.

  9. Determination of solute descriptors by chromatographic methods.

    PubMed

    Poole, Colin F; Atapattu, Sanka N; Poole, Salwa K; Bell, Andrea K

    2009-10-12

    The solvation parameter model is now well established as a useful tool for obtaining quantitative structure-property relationships for chemical, biomedical and environmental processes. The model correlates a free-energy related property of a system to six free-energy derived descriptors describing molecular properties. These molecular descriptors are defined as L (gas-liquid partition coefficient on hexadecane at 298K), V (McGowan's characteristic volume), E (excess molar refraction), S (dipolarity/polarizability), A (hydrogen-bond acidity), and B (hydrogen-bond basicity). McGowan's characteristic volume is trivially calculated from structure and the excess molar refraction can be calculated for liquids from their refractive index and easily estimated for solids. The remaining four descriptors are derived by experiment using (largely) two-phase partitioning, chromatography, and solubility measurements. In this article, the use of gas chromatography, reversed-phase liquid chromatography, micellar electrokinetic chromatography, and two-phase partitioning for determining solute descriptors is described. A large database of experimental retention factors and partition coefficients is constructed after first applying selection tools to remove unreliable experimental values and an optimized collection of varied compounds with descriptor values suitable for calibrating chromatographic systems is presented. These optimized descriptors are demonstrated to be robust and more suitable than other groups of descriptors characterizing the separation properties of chromatographic systems.

  10. [Study on the analysis of organogermanium compounds by ion chromatography].

    PubMed

    Chen, Q; Mou, S; Hou, X; Ni, Z

    1997-05-01

    A new high performance ion exchange chromatographic method for separation and determination of three organogermanium compounds beta-carboxyethylgermanium sesquioxide (I), beta-(alpha-methyl) carboxyethylgermanium sesquioxide (II) and di-(beta-carboxyethyl) germanium hydroxide (III) has been developed. A Dionex DX-300 Ion Chromatograph equipped with a Dionex PED-II pulsed electrochemical detector (conductivity mode), a Dionex AMMS-1 anion micromembrane suppressor, and a Dionex ACI advanced computer interface coupled with AI-450 chromatographic software was employed. The separation was achieved by using a Dionex IonPac AS4A-SC column as analytical column, sodium tetraborate solution as eluent, and sulfuric acid solution as regenerant. For reducing run time, a gradient program was chosen. The detection limits (S/N = 3, expressed as germanium) for the three compounds were 0.038mg/L (I), 0.035mg/L (II) and 0.025mg/L (III), respectively. The method has been applied to the analysis of two tonic oral drinks, and the average recoveries for the three compounds ranged from 95%-101%. The results obtained were in agreement with those of hydride generation atomic fluorescence spectrometry (HG-AFS).

  11. Application of ionic liquids in liquid chromatography and electrodriven separation.

    PubMed

    Huang, Yi; Yao, Shun; Song, Hang

    2013-08-01

    Ionic liquids (ILs) are salts in the liquid state at ambient temperature, which are nonvolatile, nonflammable with high thermal stability and dissolve easily for a wide range of inorganic and organic materials. As a kind of potential green solvent, they show high efficiency and selectivity in the field of separation research, especially in instrumental analysis. Thus far, ILs have been successfully applied by many related researchers in high-performance liquid chromatography and capillary electrophoresis as chromatographic stationary phases, mobile phase additives or electroosmotic flow modifiers. This paper provides a detailed review of these applications in the study of natural products, foods, drugs and other fine chemicals. Furthermore, the prospects of ILs in liquid chromatographic and electrodriven techniques are discussed.

  12. Chromatographic and electrophoretic approaches in ink analysis.

    PubMed

    Zlotnick, J A; Smith, F P

    1999-10-15

    Inks are manufactured from a wide variety of substances that exhibit very different chemical behaviors. Inks designed for use in different writing instruments or printing methods have quite dissimilar components. Since the 1950s chromatographic and electrophoretic methods have played important roles in the analysis of inks, where compositional information may have bearing on the investigation of counterfeiting, fraud, forgery, and other crimes. Techniques such as paper chromatography and electrophoresis, thin-layer chromatography, high-performance liquid chromatography, gas chromatography, gel electrophoresis, and the relatively new technique of capillary electrophoresis have all been explored as possible avenues for the separation of components of inks. This paper reviews the components of different types of inks and applications of the above separation methods are reviewed.

  13. Recovery of lactic acid from the pretreated fermentation broth based on a novel hyper-cross-linked meso-micropore resin: Modeling.

    PubMed

    Song, Mingkai; Jiao, Pengfei; Qin, Taotao; Jiang, Kangkang; Zhou, Jingwei; Zhuang, Wei; Chen, Yong; Liu, Dong; Zhu, Chenjie; Chen, Xiaochun; Ying, Hanjie; Wu, Jinglan

    2017-10-01

    An innovative benign process for recovery lactic acid from its fermentation broth is proposed using a novel hyper-cross-linked meso-micropore resin and water as eluent. This work focuses on modeling the competitive adsorption behaviors of glucose, lactic acid and acetic acid ternary mixture and explosion of the adsorption mechanism. The characterization results showed the resin had a large BET surface area and specific pore structure with hydrophobic properties. By analysis of the physicochemical properties of the solutes and the resin, the mechanism of the separation is proposed as hydrophobic effect and size-exclusion. Subsequently three chromatographic models were applied to predict the competitive breakthrough curves of the ternary mixture under different operating conditions. The pore diffusion was the major limiting factor for the adsorption process, which was consistent with the BET results. The novel HD-06 resin can be a good potential adsorbent for the future SMB continuous separation process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Assessment of the antioxidant and antibacterial activities of different olive processing wastewaters

    PubMed Central

    Tan, Shiau Pin; El-Abbassi, Abdelilah; Kiai, Hajar; Hafidi, Abdellatif; O’Donovan, Orla; McLoughlin, Peter

    2017-01-01

    Olive processing wastewaters (OPW), namely olive mill wastewater (OMW) and table-olive wastewaters (TOW) were evaluated for their antibacterial activity against five Gram-positive and two Gram-negative bacteria using the standard disc diffusion and thin layer chromatography (TLC)-bioautography assays. Disc diffusion screening and bioautography of OMW were compared to the phenolic extracts of table-olive brines. Positive activity against S. aureus was demonstrated. The optimization of chromatographic separation revealed that hexane/acetone in the ratio of 4:6 was the most effective for phenolic compounds separation. A HPLC-MS analysis was performed showing that only two compounds, hydroxytyrosol and tyrosol, were the predominant phenolic compounds in all OPW. The phenolic extract of OMW generated by a semi-modern process showed the highest free radical-scavenging activity (DPPH assay) compared to the other phenolic extracts. It is apparent from the present study that OPW are a rich source of antioxidants suitable for use in food, cosmetic or pharmaceutical applications. PMID:28873097

  15. Investigation of Soman Adducts of Human Hemoglobin by Liquid Chromatography

    DTIC Science & Technology

    2004-04-01

    acid standard, with fifteen primary amino acids , was used to evaluate and refine the chromatographic methods . An LC/MS/MS was used to analyze the non...several chromatographic conditions and stationary phases were used to create an LC/MS/MS method to directly analyze the amino acids , these studies...terminated because of a lack of resolution of the amino acid peaks. Also, initial attempts to develop an HPLC method to separate individual amino acids

  16. Analysis of Wastewater for Organic Compounds Unique to RDX/HMX manufacturing and Processing

    DTIC Science & Technology

    1979-12-01

    Evaporation 6.. ............ 6 Analytical Separation’and Identification.• 6Gas Chromatography. 6 Liquid Chromatography ( LC )’and’Infrared Analyses (iR...steam-heated system. This conclusion was arrived at by comparing chromatograms relative to numbers of, and intensity of the component peaks . Analytical...for chromatographing the samples are listed below: (1) 10% UC-W-98 on Chrom G-AW-DMCS 0.61 m x 6.3 mm (2 ft. x ¼ in.) glass col umn (2) 10% UC-W-98 on

  17. Automated Drug Identification for Urban Hospitals

    NASA Technical Reports Server (NTRS)

    Shirley, Donna L.

    1971-01-01

    Many urban hospitals are becoming overloaded with drug abuse cases requiring chemical analysis for identification of drugs. In this paper, the requirements for chemical analysis of body fluids for drugs are determined and a system model for automated drug analysis is selected. The system as modeled, would perform chemical preparation of samples, gas-liquid chromatographic separation of drugs in the chemically prepared samples, infrared spectrophotometric analysis of the drugs, and would utilize automatic data processing and control for drug identification. Requirements of cost, maintainability, reliability, flexibility, and operability are considered.

  18. Practical comparison of 2.7 microm fused-core silica particles and porous sub-2 microm particles for fast separations in pharmaceutical process development.

    PubMed

    Abrahim, Ahmed; Al-Sayah, Mohammad; Skrdla, Peter; Bereznitski, Yuri; Chen, Yadan; Wu, Naijun

    2010-01-05

    Fused-core silica stationary phases represent a key technological advancement in the arena of fast HPLC separations. These phases are made by fusing a 0.5 microm porous silica layer onto 1.7 microm nonporous silica cores. The reduced intra-particle flow path of the fused particles provides superior mass transfer kinetics and better performance at high mobile phase velocities, while the fused-core particles provide lower pressure than sub-2 microm particles. In this work, chromatographic performance of the fused-core particles (Ascentis Express) was investigated and compared to that of sub-2 microm porous particles (1.8 microm Zorbax Eclipse Plus C18 and 1.7 microm Acquity BEH C18). Specifically, retention, selectivity, and loading capacity were systematically compared for these two types of columns. Other chromatographic parameters such as efficiency and pressure drop were also studied. Although the fused-core column was found to provide better analyte shape selectivity, both columns had similar hydrophobic, hydrogen bonding, total ion-exchange, and acidic ion-exchange selectivities. As expected, the retention factors and sample loading capacity on the fused-core particle column were slightly lower than those for the sub-2 microm particle column. However, the most dramatic observation was that similar efficiency separations to the sub-2 microm particles could be achieved using the fused-core particles, without the expense of high column back pressure. The low pressure of the fused-core column allows fast separations to be performed routinely on a conventional LC system without significant loss in efficiency or resolution. Applications to the HPLC impurity profiling of drug substance candidates were performed using both types of columns to validate this last point.

  19. ADSORPTION METHOD FOR SEPARATING METAL CATIONS

    DOEpatents

    Khym, J.X.

    1959-03-10

    The chromatographic separation of fission product cations is discussed. By use of this method a mixture of metal cations containing Zr, Cb, Ce, Y, Ba, and Sr may be separated from one another. Mentioned as preferred exchange adsorbents are resins containing free sulfonic acid groups. Various eluants, such as tartaric acid, HCl, and citric acid, used at various acidities, are employed to effect the selective elution and separation of the various fission product cations.

  20. Post-synthetic modification of MIL-101(Cr) with pyridine for high-performance liquid chromatographic separation of tocopherols.

    PubMed

    Yang, Fang; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2015-05-01

    Effective separation of tocopherols is challenging and significant due to their structural similarity and important biological role. Here we report the post-synthetic modification of metal-organic framework (MOF) MIL-101(Cr) with pyridine for high-performance liquid chromatographic (HPLC) separation of tocopherols. Baseline separation of four tocopherols was achieved on a pyridine-grafted MIL-101(Cr) packed column within 10 min using hexane/isopropanol (96:4, v/v) as the mobile phase at a flow rate of 0.5 mL min(-1). The pyridine-grafted MIL-101(Cr) packed column gave high column efficiency (85,000 plates m(-1) for δ-tocopherol) and good precision (0.2-0.3% for retention time, 1.8-3.4% for peak area, 2.6-2.7% for peak height), and also offered much better performance than unmodified MIL-101(Cr) and commercial amino-bonded silica packed column for HPLC separation of tocopherols. The results not only show the promising application of pyridine-grafted MIL-101(Cr) as a novel stationary phase for HPLC separation of tocopherols, but also reveal a facile post-modification of MOFs to expand the application of MOFs in separation sciences. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Phase equilibria in fullerene-containing systems as a basis for development of manufacture and application processes for nanocarbon materials

    NASA Astrophysics Data System (ADS)

    Semenov, K. N.; Charykov, N. A.; Postnov, V. N.; Sharoyko, V. V.; Murin, I. V.

    2016-01-01

    This review is the first attempt to integrate the available data on all types of phase equilibria (solubility, extraction and sorption) in systems containing light fullerenes (C60 and C70). In the case of solubility diagrams, the following types of phase equilibria are considered: individual fullerene (C60 or C70)-solvent under polythermal and polybaric conditions; C60-C70-solvent, individual fullerene-solvent(1)-solvent(2), as well as multicomponent systems comprising a single fullerene or an industrial mixture of fullerenes and vegetable oils, animal fats or essential oils under polythermal conditions. All published experimental data on the extraction equilibria in C60-C70-liquid phase(1)-liquid phase(2) systems are described systematically and the sorption characteristics of various materials towards light fullerenes are estimated. The possibility of application of these experimental data for development of pre-chromatographic and chromatographic methods for separation of fullerene mixtures and application of fullerenes as nanomodifiers are described. The bibliography includes 87 references.

  2. New support for high-performance liquid chromatography based on silica coated with alumina particles.

    PubMed

    Silveira, José Leandro R; Dib, Samia R; Faria, Anizio M

    2014-01-01

    A new material based on silica coated with alumina nanoparticles was proposed for use as a chromatographic support for reversed-phase high-performance liquid chromatography. Alumina nanoparticles were synthesized by a sol-gel process in reversed micelles composed of sodium bis(2-ethylhexyl)sulfosuccinate, and the support material was formed by the self-assembly of alumina layers on silica spheres. Spectroscopic and (29)Si nuclear magnetic resonance results showed evidence of chemical bonds between the alumina nanoparticles and the silica spheres, while morphological characterizations showed that the aluminized silica maintained the morphological properties of silica desired for chromatographic purposes after alumina incorporation. Stability studies indicated that bare silica showed high dissolution (~83%), while the aluminized silica remained practically unchanged (99%) after passing one liter of the alkaline mobile phase, indicating high stability under alkaline conditions. The C18 bonded aluminized silica phase showed great potential for use in high-performance liquid chromatography to separate basic molecules in the reversed-phase mode.

  3. Monitoring of Time-Dependent System Profiles by Multiplex Gas Chromatography with Maximum Entropy Demodulation

    NASA Technical Reports Server (NTRS)

    Becker, Joseph F.; Valentin, Jose

    1996-01-01

    The maximum entropy technique was successfully applied to the deconvolution of overlapped chromatographic peaks. An algorithm was written in which the chromatogram was represented as a vector of sample concentrations multiplied by a peak shape matrix. Simulation results demonstrated that there is a trade off between the detector noise and peak resolution in the sense that an increase of the noise level reduced the peak separation that could be recovered by the maximum entropy method. Real data originated from a sample storage column was also deconvoluted using maximum entropy. Deconvolution is useful in this type of system because the conservation of time dependent profiles depends on the band spreading processes in the chromatographic column, which might smooth out the finer details in the concentration profile. The method was also applied to the deconvolution of previously interpretted Pioneer Venus chromatograms. It was found in this case that the correct choice of peak shape function was critical to the sensitivity of maximum entropy in the reconstruction of these chromatograms.

  4. [Extraction of 10-Deacetyl Baccatin by Supercritical CO2 from Taxus yunnanensis Branches and Leaves].

    PubMed

    Tang, Yang-qin; Li, Hai-chi; Huang, Wen-jie; Xiong, Yan; Ge, Fa-huan

    2015-04-01

    To study the supercritical CO2 fluids extraction (SFE) method to extract the components from Taxus yunnanensis. Medicinal meterials were extracted by supercritical CO2, and then purified by industrial chromatography. Using the extraction yield of 10-DAB as the index,single factor test was carried out to investigate the effect of co-solvent, extraction time, extraction pressure, extraction temperature, pressure and temperature of separation kettle I. Then orthogonal experiment was used to optimize the best extraction condition. The suitable extraction condition was as follows: the ratio of co-solvent (80% ethanol) amount and the madicinal materials was 3: 1, Separation kettle I pressure was 14 MPa, separation kettle I temperature was 40 °C, extraction pressure was 25 MPa, extraction temperature was 60 T and extraction time was 90 min. The extract was separated by industrial chromatographic and then crystallized. The supercritical CO2 extraction and purification process of 10-DAB were simple and feasible.

  5. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    USGS Publications Warehouse

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  6. Impact of solvent conditions on separation and detection of basic drugs by micro liquid chromatography-mass spectrometry under overloading conditions.

    PubMed

    Schubert, Birthe; Oberacher, Herbert

    2011-06-03

    In this study the impact of solvent conditions on the performance of μLC/MS for the analysis of basic drugs was investigated. Our aim was to find experimental conditions that enable high-performance chromatographic separation particularly at overloading conditions paired with a minimal loss of mass spectrometric detection sensitivity. A focus was put on the evaluation of the usability of different kinds of acidic modifiers (acetic acid (HOAc), formic acid (FA), methansulfonic acid (CH₃SO₃H), trifluoroacetic acid (TFA), pentafluoropropionic acid (PFPA), and heptafluorobutyric acid (HFBA)). The test mixture consisted of eleven compounds (bunitrolol, caffeine, cocaine, codeine, diazepam, doxepin, haloperidol, 3,4-methylendioxyamphetamine, morphine, nicotine, and zolpidem). Best chromatographic performance was obtained with the perfluorinated acids. Particularly, 0.010-0.050% HFBA (v/v) was found to represent a good compromise in terms of chromatographic performance and mass spectrometric detection sensitivity. Compared to HOAc, on average a 50% reduction of the peak widths was observed. The use of HFBA was particularly advantageous for polar compounds such as nicotine; only with such a hydrophobic ion-pairing reagent chromatographic retention of nicotine was observed. Best mass spectrometric performance was obtained with HOAc and FA. Loss of detection sensitivity induced by HFBA, however, was moderate and ranged from 0 to 40%, which clearly demonstrates that improved chromatographic performance is able to compensate to a large extent the negative effect of reduced ionization efficiency on detection sensitivity. Applications of μLC/MS for the qualitative and quantitative analysis of clinical and forensic toxicological samples are presented. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    PubMed

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time-consuming sample preparation and chromatographic separation processes. This flow injection-based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Isolation and Purification of Antibiotic Material from Physarum gyrosum

    PubMed Central

    Schroeder, H. R.; Mallette, M. F.

    1973-01-01

    The myxomycete Physarum gyrosum was cultured in its plasmodial stage on agar plates containing 0.025 M phosphate buffer at pH 6.5, 2% bakers' yeast, and 0.2% glucose and was supplemented with live Escherichia coli. Extracts of these plasmodia contained several antibiotic substances. Antibiotic materials were partially purified by dialysis of the agar medium-mold mixture, evaporation of the dialyzate, and butanol extraction of the residue. Further purification in two paper and two thin-layer chromatographic systems gave one product which was pure in six thin-layer chromatographic systems. Antibiotic activity against some gram-positive and gram-negative bacteria and yeasts was demonstrated with partially purified extracts and a paper-chromatographically separated fraction. One pure antibiotic was effective against Bacillus cereus. PMID:4799591

  9. Analysis of metalaxyl racemate using high performance liquid chromatography coupled with four kinds of detectors.

    PubMed

    Chen, Tao; Fan, Jun; Gao, Ruiqi; Wang, Tai; Yu, Ying; Zhang, Weiguang

    2016-10-07

    Chiral stationary phase-high performance liquid chromatography coupled with various detectors has been one of most commonly used methods for analysis and separation of chiral compounds over the past decades. Various detectors exhibit different characteristics in qualitative and quantitative studies under different chromatographic conditions. Herein, a comparative evaluation of HPLC coupled with ultraviolet, optical rotation, refractive index, and evaporative light scattering detectors has been conducted for qualitative and quantitative analyses of metalaxyl racemate. Effects of separation conditions on the peak area ratio between two enantiomers, including sample concentration, column temperature, mobile phase composition, as well as flow rate, have been investigated in detail. In addition, the limits of detection, the limits of quantitation, quantitative range and precision for these two enantiomers by using four detectors have been also studied. As indicated, the chromatographic separation conditions have been slight effects on ultraviolet and refractive index detections and the peak area ratio between two enantiomers remains almost unchanged, but the evaporative light scattering detection has been significantly affected by the above-mentioned chromatographic conditions and the corresponding peak area ratios varied greatly. Moreover, the limits of detection, the limits of quantitation, and the quantitative ranges of two enantiomers with UV detection were remarkably lower by 1-2 magnitudes than the others. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Unexpected retention behavior of baicalin: Hydrophilic interaction like properties of a reversed-phase column.

    PubMed

    Magda, Balázs; Márta, Zoltán; Imre, Tímea; Kalapos-Kovács, Bernadett; Klebovich, Imre; Fekete, Jenő; Szabó, Pál T

    2015-01-01

    The original aim of this study was to develop a method for the determination of baicalin from membrane vesicles. The unconventional chromatographic separation ("inverse gradient elution" on a reversed phase column) was due to a lucky chance, which is detailed and discussed in this study. The validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is proved to be sensitive, rapid and selective. Chromatographic separation was performed on a Zorbax SB-C8 column (250 mm × 4.6 mm, i.d.; 5 μm) with 0.1% formic acid in water and methanol by linear gradient elution. Quantification of baicalin was determined by multiple reaction monitoring (MRM) mode using electrospray ionization (ESI). The calibration curve was linear (r = 0.9987) over the concentration range from 1 to 1000 nM. The coefficient of variation and relative error of baicalin for intra- and inter-assay at three quality control (QC) levels were 2.0-10.2% and -6.1 to 6.7%, respectively. The lower limit of quantification (LLOQ) for baicalin was 1 nM (0.446 ng/ml), without preconcentration of the sample. This method was subsequently applied to vesicular transport assays of baicalin in membrane vesicles successfully. The developed method can open up new area of research in the chromatographic separation of flavonoids and their glucuronides. Copyright © 2015. Published by Elsevier B.V.

  11. Determination of Phenolic Acids in Sugarcane Vinasse by HPLC with Pulse Amperometry

    PubMed Central

    Freitas, P. V.; Beluomini, M. A.; da Silva, J. L.; Stradiotto, N. R.

    2018-01-01

    A reversed-phase liquid chromatographic separation with pulsed amperometric detection of phenolic acids at a glassy carbon electrode is described. Chromatographic separation was carried out in isocratic conditions using 0.20 mol·L−1 acetic acid (pH 5.0)/water (80 : 20, v/v) as mobile phase under constant working potential mode of 0.80 V. Chromatographic peaks presented high resolution and separation. Calibration curves exhibited excellent correlation coefficients, above 0.995. Linear ranges of the analytes, in mg L−1, were of 0.018–18 (gallic acid), 0.146–19 (vanillic acid), 0.13–17 (caffeic acid), 0.016–16 (ferulic acid), and 0.008–17 (p-coumaric acid), respectively. Limits of detection ranged from 1.6 to 97 μg·L−1 and precision varied in 1.73–3.78% interval. Concentrations of 19 ± 0.51 mg·L−1 and 7.8 ± 2.5 mg·L−1 were found for vanillic and caffeic acids, respectively, in a sugarcane vinasse sample. Gallic, ferulic, and p-coumaric acids were not detected. Recovery results demonstrated that the proposed method is accurate, and it can be used to detect and quantify phenolic acids in sugarcane vinasse without any influence of interferents. PMID:29600112

  12. Comparison of various types of stationary phases in non-aqueous reversed-phase high-performance liquid chromatography-mass spectrometry of glycerolipids in blackcurrant oil and its enzymatic hydrolysis mixture.

    PubMed

    Lísa, Miroslav; Holcapek, Michal; Sovová, Helena

    2009-11-20

    The selection of column packing during the development of high-performance liquid chromatography method is a crucial step to achieve sufficient chromatographic resolution of analyzed species in complex mixtures. Various stationary phases are tested in this paper for the analysis of complex mixture of triacylglycerols (TGs) in blackcurrant oil using non-aqueous reversed-phase (NARP) system with acetonitrile-2-propanol mobile phase. Conventional C(18) column in the total length of 45 cm is used for the separation of TGs according to their equivalent carbon number, the number and positions of double bonds and acyl chain lengths. The separation of TGs and their more polar hydrolysis products after the partial enzymatic hydrolysis of blackcurrant oil in one chromatographic run is achieved using conventional C(18) column. Retention times of TGs are reduced almost 10 times without the loss of the chromatographic resolution using ultra high-performance liquid chromatography with 1.7 microm C(18) particles. The separation in NARP system on C(30) column shows an unusual phenomenon, because the retention order of TGs changes depending on the column temperature, which is reported for the first time. The commercial monolithic column modified with C(18) is used for the fast analysis of TGs to increase the sample throughput but at cost of low resolution.

  13. A review on solid phase extraction of actinides and lanthanides with amide based extractants.

    PubMed

    Ansari, Seraj A; Mohapatra, Prasanta K

    2017-05-26

    Solid phase extraction is gaining attention from separation scientists due to its high chromatographic utility. Though both grafted and impregnated forms of solid phase extraction resins are popular, the later is easy to make by impregnating a given organic extractant on to an inert solid support. Solid phase extraction on an impregnated support, also known as extraction chromatography, combines the advantages of liquid-liquid extraction and the ion exchange chromatography methods. On the flip side, the impregnated extraction chromatographic resins are less stable against leaching out of the organic extractant from the pores of the support material. Grafted resins, on the other hand, have a higher stability, which allows their prolong use. The goal of this article is a brief literature review on reported actinide and lanthanide separation methods based on solid phase extractants of both the types, i.e., (i) ligand impregnation on the solid support or (ii) ligand functionalized polymers (chemically bonded resins). Though the literature survey reveals an enormous volume of studies on the extraction chromatographic separation of actinides and lanthanides using several extractants, the focus of the present article is limited to the work carried out with amide based ligands, viz. monoamides, diamides and diglycolamides. The emphasis will be on reported applied experimental results rather than on data pertaining fundamental metal complexation. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Development and evaluation of a hydrophilic interaction liquid chromatography-MS/MS method to quantify 19 nucleobases and nucleosides in rat plasma.

    PubMed

    Du, Yan; Li, Yin-Jie; Hu, Xun-Xiu; Deng, Xu; Qian, Zeng-Ting; Li, Zheng; Guo, Meng-Zhe; Tang, Dao-Quan

    2017-04-01

    As essential endogenous compounds, nucleobases and nucleosides fulfill various functions in living organisms. This study presents the development and validation of a new hydrophilic interaction liquid chromatography tandem mass spectrometry method for simultaneous quantification of 19 nucleobases and nucleosides in rat plasma. For the sample preparation, 15 kinds of protein precipitants were evaluated according to the chromatographic profile and ion response of analytes. The optimization of chromatographic separation was respectively performed using reversed-phase liquid chromatography and hydrophilic interaction liquid chromatography mode; each separation mode included two test columns with different stationary phases. The chromatographic profile and parameters such as half-width (W 1/2 ), capacity factor (K') and tailing factor (f t ) were used to evaluate the separation efficiencies. Furthermore, the adopted composition of two mobile phase systems and the concentrations of the additives in the optimum buffer system were also investigated. The developed method was fully validated and successfully applied quantitatively to determine 19 nucleobases and nucleosides in plasma from normal and diabetic nephropathy (DN) rats. Significant differences between normal and DN rats were found in plasma levels of cytosine, xanthine, thymidine, adenosine, guanosine, inosine and 8-hydroxy-2'-deoxyguanosine. This information may provide a useful reference for the discovery of potential biomarkers of DN. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Experimental designs for modeling retention patterns and separation efficiency in analysis of fatty acid methyl esters by gas chromatography-mass spectrometry.

    PubMed

    Skartland, Liv Kjersti; Mjøs, Svein A; Grung, Bjørn

    2011-09-23

    The retention behavior of components analyzed by chromatography varies with instrumental settings. Being able to predict how changes in these settings alter the elution pattern is useful, both with regards to component identification, as well as with regards to optimization of the chromatographic system. In this work, it is shown how experimental designs can be used for this purpose. Different experimental designs for response surface modeling of the separation of fatty acid methyl esters (FAME) as function of chromatographic conditions in GC have been evaluated. Full factorial, central composite, Doehlert and Box-Behnken designs were applied. A mixture of 38 FAMEs was separated on a polar cyanopropyl substituted polysilphenylene-siloxane phase capillary column. The temperature gradient, the start temperature of the gradient, and the carrier gas velocity were varied in the experiments. The modeled responses, as functions of chromatographic conditions, were retention time, retention indices, peak widths, separation efficiency and resolution between selected peak pairs. The designs that allowed inclusion of quadratic terms among the predictors performed significantly better than factorial design. Box-Behnken design provided the best results for prediction of retention, but the differences between the central composite, Doehlert and Box-Behnken designs were small. Retention indices could be modeled with much better accuracy than retention times. However, because the errors of predicted tR of closely eluting peaks were highly correlated, models of resolution (Rs) that were based on retention time had errors in the same range as corresponding models based on ECL. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. SEPARATION AND CHARACTERIZATION OF TETROL METABOLITES OF BENZO[A]PYRENE-DNA ADDUCTS USING HPLC AND SOLID-MATRIX ROOM TEMPERATURE LUMINESCENCE. (R824100)

    EPA Science Inventory

    Abstract

    Four tetrols of benzo[a]pyrene-DNA adducts were separated using reversed-phase high performance liquid chromatography. Chromatographic fractions containing a given tetrol were readily characterized with solid-matrix room temperature luminescence techniques. So...

  17. Separation Anxiety: An in-Class Game Designed to Help Students Discover Chromatography

    ERIC Educational Resources Information Center

    Samide, Michael J.

    2008-01-01

    An in-class activity has been developed to assist students in discovering chromatographic separations. Designed on the basis of plate theory, the game has students use instructor-provided partition coefficients to establish equilibrium for two different items between a stationary and mobile phase. As students work through equilibration and mobile…

  18. Thin-layer chromatographic (TLC) separations and bioassays of plant extracts to identify antimicrobial compounds

    USDA-ARS?s Scientific Manuscript database

    A common screen for plant antimicrobial compounds consists of separating plant extracts by paper or thin-layer chromatography (PC or TLC), exposing the chromatograms to microbial suspensions (e.g. fungal spores in nutrient solution or bacteria in liquefied agar), allowing time for the microbes to gr...

  19. High-temperature adsorption layers based on fluoridated polyimide and diatomite carrier

    NASA Astrophysics Data System (ADS)

    Yakovleva, E. Yu.; Shundrina, I. K.; Gerasimov, E. Yu.

    2017-09-01

    A way of preparing separation layers by the pyrolysis of fluorinated polyimide obtained from 2,4,6-trimethyl- m-phenylenediamine (2,4,6-TM mPDA) and 2,2-bis(3',4'-dicarboxyphenyl)hexafluoropropane (6FDA) applied onto a diatomite carrier is described. Thermogravimetry, elemental analysis, low-temperature nitrogen adsorption, high-resolution electron microscopy, and gas chromatography are used to study changes in the texture and chromatographic characteristics of these layers. It is found that changes in the structure and the effectivity of separation characteristic of the layers depend on the temperature of pyrolysis, which ranges from 250 to 1100°C. It is established that a layer of separation is formed at 250-350°C, and the order of elution of hydrocarbons is similar to their chromatographic behavior on such stationary phases as OV-101. Layers of amorphous carbon formed on the surfaces of individual particles on a diatomite surface at 500-700°C. These layers ensure highly stable and selective separation of permanent gases and hydrocarbons when they are present together.

  20. Molecular recognition principles and stationary-phase characteristics of topoisomer-selective chemoaffinity materials for chromatographic separation of circular plasmid DNA topoisomers.

    PubMed

    Mahut, Marek; Lindner, Wolfgang; Lämmerhofer, Michael

    2012-01-18

    We recently discovered the molecular recognition capability of a quinine carbamate ligand attached to silica as a powerful chemoaffinity material for the chromatographic separation of circular plasmid topoisomers of different linking numbers. In this paper we develop structure-selectivity relationship studies to figure out the essential structural features for topoisomer recognition. By varying different moieties of the original cinchonan-derived selector, it was shown that intercalation by the quinoline moiety of the ligand as assumed initially as the working hypothesis is not an essential feature for topoisomer recognition during chromatography. We found that the key elements for topoisomer selectivity are the presence of a rigid weak anion-exchange site and a H-donor site separated from each other in a defined distance by a 4-atom spacer. Additionally, incorporation of the weak anion-exchange site into a cyclic ring structure provides greater rigidity of the ligand molecule and turned out to be advantageous, if not mandatory, for (close to) baseline separation. © 2011 American Chemical Society

  1. Chromatographic Studies of Protein-Based Chiral Separations

    PubMed Central

    Bi, Cong; Zheng, Xiwei; Azaria, Shiden; Beeram, Sandya; Li, Zhao; Hage, David S.

    2016-01-01

    The development of separation methods for the analysis and resolution of chiral drugs and solutes has been an area of ongoing interest in pharmaceutical research. The use of proteins as chiral binding agents in high-performance liquid chromatography (HPLC) has been an approach that has received particular attention in such work. This report provides an overview of proteins that have been used as binding agents to create chiral stationary phases (CSPs) and in the use of chromatographic methods to study these materials and protein-based chiral separations. The supports and methods that have been employed to prepare protein-based CSPs will also be discussed and compared. Specific types of CSPs that are considered include those that employ serum transport proteins (e.g., human serum albumin, bovine serum albumin, and alpha1-acid glycoprotein), enzymes (e.g., penicillin G acylase, cellobiohydrolases, and α-chymotrypsin) or other types of proteins (e.g., ovomucoid, antibodies, and avidin or streptavidin). The properties and applications for each type of protein and CSP will also be discussed in terms of their use in chromatography and chiral separations. PMID:28344977

  2. Two-dimensional RPLC-RPLC system with different pH in two dimensions for separation of alkaloids from Corydalis yanhusuo W. T. Wang.

    PubMed

    Zhang, Jing; Jin, Yu; Liu, Yanfang; Xiao, Yuansheng; Feng, Jiatao; Xue, Xingya; Zhang, Xiuli; Liang, Xinmiao

    2009-06-01

    An effective method utilizing the same RP chromatographic column with different pH in first and second LC dimensions has been developed for separation of the basic compounds from traditional Chinese medicines (TCMs). In this work, the alkaloids in Corydalis yanhusuo which is an important TCM were selected as a model to develop the method. The additives and pH values of the mobile phase were optimized in this work. To investigate the feasibility of this method, off-line mode separation was performed in the experiments. According to the UV-absorption intensity, there were eight fractions collected in acidic conditions. All the fractions were analyzed in basic conditions. The results showed that the chromatographic selectivities were significantly different in the separations performed with acidic and alkaline elution systems. Complementary separation was achieved in this work. It is demonstrated that this method would be an effective tool for alkaloids research. Based on the different pH of the mobile phase in this method, it could also be suitable to analyze compounds which were sensible to the pH of the solution.

  3. Chiral magnetic microspheres purified by centrifugal field flow fractionation and microspheres magnetic chiral chromatography for benzoin racemate separation

    PubMed Central

    Tian, Ailin; Qi, Jing; Liu, Yating; Wang, Fengkang; Ito, Yoichiro; Wei, Yun

    2013-01-01

    Separation of enantiomers still remains a challenge due to their identical physical and chemical properties in a chiral environment, and the research on specific chiral selector along with separation techniques continues to be conducted to resolve individual enantiomers. In our laboratory the promising magnetic chiral microspheres Fe3O4@SiO2@cellulose-2, 3-bis (3, 5-dimethylphenylcarbamate) have been developed to facilitate the resolution using both its magnetic property and chiral recognition ability. In our present studies this magnetic chiral selector was first purified by centrifuge field flow fractionation, and then used to separate benzoin racemate by a chromatographic method. Uniform-sized and masking-impurity-removed magnetic chiral selector was first obtained by field flow fractionation with ethanol through a spiral column mounted on the type-J planetary centrifuge, and using the purified magnetic chiral selector, the final chromatographic separation of benzoin racemate was successfully performed by eluting with ethanol through a coiled tube (wound around the cylindrical magnet to retain the magnetic chiral selector as a stationary phase) submerged in dry ice. In addition, an external magnetic field facilitates the recycling of the magnetic chiral selector. PMID:23891368

  4. Rational and Efficient Preparative Isolation of Natural Products by MPLC-UV-ELSD based on HPLC to MPLC Gradient Transfer.

    PubMed

    Challal, Soura; Queiroz, Emerson Ferreira; Debrus, Benjamin; Kloeti, Werner; Guillarme, Davy; Gupta, Mahabir Prashad; Wolfender, Jean-Luc

    2015-11-01

    In natural product research, the isolation of biomarkers or bioactive compounds from complex natural extracts represents an essential step for de novo identification and bioactivity assessment. When pure natural products have to be obtained in milligram quantities, the chromatographic steps are generally labourious and time-consuming. In this respect, an efficient method has been developed for the reversed-phase gradient transfer from high-performance liquid chromatography to medium-performance liquid chromatography for the isolation of pure natural products at the level of tens of milligrams from complex crude natural extracts. The proposed method provides a rational way to predict retention behaviour and resolution at the analytical scale prior to medium-performance liquid chromatography, and guarantees similar performances at both analytical and preparative scales. The optimisation of the high-performance liquid chromatography separation and system characterisation allows for the prediction of the gradient at the medium-performance liquid chromatography scale by using identical stationary phase chemistries. The samples were introduced in medium-performance liquid chromatography using a pressure-resistant aluminium dry load cell especially designed for this study to allow high sample loading while maintaining a maximum achievable flow rate for the separation. The method has been validated with a mixture of eight natural product standards. Ultraviolet and evaporative light scattering detections were used in parallel for a comprehensive monitoring. In addition, post-chromatographic mass spectrometry detection was provided by high-throughput ultrahigh-performance liquid chromatography time-of-flight mass spectrometry analyses of all fractions. The processing of all liquid chromatography-mass spectrometry data in the form of an medium-performance liquid chromatography x ultra high-performance liquid chromatography time-of-flight mass spectrometry matrix enabled an efficient localisation of the compounds of interest in the generated fractions. The methodology was successfully applied for the separation of three different plant extracts that contain many diverse secondary metabolites. The advantages and limitations of this approach and the theoretical chromatographic background that rules such as liquid chromatography gradient transfer are presented from a practical viewpoint. Georg Thieme Verlag KG Stuttgart · New York.

  5. Factorial-design optimization of gas chromatographic analysis of tetrabrominated to decabrominated diphenyl ethers. Application to domestic dust.

    PubMed

    Regueiro, Jorge; Llompart, Maria; Garcia-Jares, Carmen; Cela, Rafael

    2007-07-01

    Gas chromatographic analysis of polybrominated diphenyl ethers (PBDEs) has been evaluated in an attempt to achieve better control of the separation process, especially for highly substituted congeners. Use of a narrow-bore capillary column enabled adequate determination of tetra, penta, hexa, hepta, octa, nona and decaBDE congeners in only one chromatographic run while maintaining resolution power similar to that of conventional columns. A micro electron-capture detector (GC-microECD) was used. Chromatographic conditions were optimized by multifactorial experimental design, with the objective of obtaining not only high sensitivity but also good precision. In this way two different approaches to maximizing response and minimizing variability were tested, and are fully discussed. These optimum chromatographic conditions were then used to determine PBDEs extracted from domestic dust samples by microwave-assisted solvent extraction (MASE). Quantitative recovery (90-108%) was achieved for all the PBDEs and method precision (RSD < 13%) was satisfactory. Accuracy was tested by use of the standard reference material SRM 2585, and sub-ng g(-1) limits of detection were obtained for all compounds except BDE-209 (1.44 ng g(-1)). Finally, several samples of house dust were analysed by use of the proposed method and all the target PBDEs were detected in all the samples. BDE-209 was the predominant congener. Amounts varied from 58 to 1615 ng g(-1) and the average contribution to the total PBDE burden of 52%. The main congeners of the octaBDE mixture (BDE-183, BDE-197, BDE-207 and BDE-196) also made an important contribution (29%) to the total. These are the first data about the presence of these compounds in European house-dust samples. Finally, the sum of the main congeners in the pentaBDE commercial mixture (BDE-47, BDE-99, and BDE-100) contributed 14% to the total. Figure Polybrominated diphenyl ethers in House Dust.

  6. Coupling state-of-the-art supercritical fluid chromatography and mass spectrometry: from hyphenation interface optimization to high-sensitivity analysis of pharmaceutical compounds.

    PubMed

    Grand-Guillaume Perrenoud, Alexandre; Veuthey, Jean-Luc; Guillarme, Davy

    2014-04-25

    The recent market release of a new generation of supercritical fluid chromatography (SFC) instruments compatible with state-of-the-art columns packed with sub-2μm particles (UHPSFC) has contributed to the reemergence of interest in this technology at the analytical scale. However, to ensure performance competitiveness of this technique with modern analytical standards, a robust hyphenation of UHPSFC to mass spectrometry (MS) is mandatory. UHPSFC-MS hyphenation interface should be able to manage the compressibility of the SFC mobile phase and to preserve as much as possible the chromatographic separation integrity. Although several interfaces can be envisioned, each will have noticeable effects on chromatographic fidelity, flexibility and user-friendliness. In the present study, various interface configurations were evaluated in terms of their impact on chromatographic efficiency and MS detection sensitivity. An interface including a splitter and a make-up solvent inlet was found to be the best compromise and exhibited good detection sensitivity while maintaining more than 75% of the chromatographic efficiency. This interface was also the most versatile in terms of applicable analytical conditions. In addition, an accurate model of the fluidics behavior of this interface was created for a better understanding of the influence of chromatographic settings on its mode of operation. In the second part, the most influential experimental factors affecting MS detection sensitivity were identified and optimized using a design-of-experiment approach. The application of low capillary voltage and high desolvation temperature and drying gas flow rate were required for optimal ESI ionization and nebulization processes. The detection sensitivity achieved using the maximized UHPSFC-ESI-MS/MS conditions for a mixture of basic pharmaceutical compounds showed 4- to 10-fold improvements in peak intensity compared to the best performance achieved by UHPLC-ESI-MS/MS with the same MS detector. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Synthetic oligonucleotide separations by mixed-mode reversed-phase/weak anion-exchange liquid chromatography.

    PubMed

    Zimmermann, Aleksandra; Greco, Roberto; Walker, Isabel; Horak, Jeannie; Cavazzini, Alberto; Lämmerhofer, Michael

    2014-08-08

    Synthetic oligonucleotides gain increasing importance in new therapeutic concepts and as probes in biological sciences. If pharmaceutical-grade purities are required, chromatographic purification using ion-pair reversed-phase chromatography is commonly carried out. However, separation selectivity for structurally closely related impurities is often insufficient, especially at high sample loads. In this study, a "mixed-mode" reversed-phase/weak anion exchanger stationary phase has been investigated as an alternative tool for chromatographic separation of synthetic oligonucleotides with minor sequence variations. The employed mixed-mode phase shows great flexibility in method development. It has been run in various gradient elution modes, viz. one, two or three parameter (mixed) gradients (altering buffer pH, buffer concentration, and organic modifier) to find optimal elution conditions and gain further insight into retention mechanisms. Compared to ion-pair reversed-phase and mere anion-exchange separation, enhanced selectivities were observed with the mixed-mode phase for 20-23 nucleotide (nt) long oligonucleotides with similar sequences. Oligonucleotides differing by 1, 2 or 3 nucleotides in length could be readily resolved and separation factors for single nucleotide replacements declined in the order Cytosine (C)/Guanine (G)>Adenine (A)/Guanine∼Guanine/Thymine (T)>Adenine/Cytosine∼Cytosine/Thymine>Adenine/Thymine. Selectivities were larger when the modification was at the 3' terminal-end, declined when it was in the middle of the sequence and was smallest when it was located at the 5' terminus. Due to the lower surface area of the 200Å pore size mixed-mode stationary phase compared to the corresponding 100Å material, lower retention times with equal selectivities under milder elution conditions were achievable. Considering high sample loading capacities of the mixed-mode anion-exchanger phase, it should have great potential for chromatographic oligonucleotide separation and purification. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Proteome wide evaluation of the separation ability of hydrophobic interaction chromatography by fluorescent dye binding analysis.

    PubMed

    Ibarra-Herrera, Celeste C; Reddy-Vennapusa, Rami; Rito-Palomares, Marco; Fernández-Lahore, Marcelo

    2013-12-01

    Hydrophobic interaction chromatography (HIC) is an important tool in the industrial purification of proteins from various sources. The HIC separation behavior of individual (or model) proteins has been widely researched by others. On the contrary, this study focused on the fractionation ability of HIC when it is challenged with whole proteomes. The impact of the nature of three different proteomes, that is, yeast, soybean, and Chinese hamster ovary cells, on HIC separation was investigated. In doing so, chromatography fractions obtained under standardized conditions were evaluated in terms of their overall hydrophobicity--as measured by fluorescence dye binding. This technique allowed for the calculation of an average protein surface hydrophobicity (S(0)) for each fraction; a unique correlation between S(0) and the observed chromatographic behavior was established in each case. Following a similar strategy, the effect of three different ligands (polypropylene glycol, phenyl, and butyl) and two adsorbent particle sizes (65 and 100 µm) on the chromatographic behavior of the yeast proteome was evaluated. As expected, the superficial hydrophobicity of the proteins eluted is correlated with the salt concentration of its corresponding elution step. The findings reveled how--and in which extent--the type of ligand and the size of the beads actually influenced the fractionation of the complex biological mixture. Summarizing, the approach presented here can be instrumental to the study of the performance of chromatography adsorbents under conditions close to industrial practice and to the development of downstream processing strategies. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Simultaneous separation and analysis of water- and fat-soluble vitamins on multi-modal reversed-phase weak anion exchange material by HPLC-UV.

    PubMed

    Dabre, Romain; Azad, Nazanin; Schwämmle, Achim; Lämmerhofer, Michael; Lindner, Wolfgang

    2011-04-01

    Several methods for the separation of vitamins on HPLC columns were already validated in the last 20 years. However, most of the techniques focus on separating either fat- or water-soluble vitamins and only few methods are intended to separate lipophilic and hydrophilic vitamins simultaneously. A mixed-mode reversed-phase weak anion exchange (RP-WAX) stationary phase was developed in our laboratory in order to address such mixture of analytes with different chemical characteristics, which are difficult to separate on standard columns. The high versatility in usage of the RP-WAX chromatographic material allowed a baseline separation of ten vitamins within a single run, seven water-soluble and three fat-soluble, using three different chromatographic modes: some positively charged vitamins are eluted in ion exclusion and ion repulsion modes whereas the negatively charged molecules are eluted in the ion exchange mechanism. The non-charged molecules are eluted in a classical reversed-phase mode, regarding their polarities. The method was validated for the vitamin analysis in tablets, evaluating selectivity, robustness, linearity, accuracy, and precision. The validated method was finally employed for the analysis of the vitamin content of some commercially available supplement tablets. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Purification of R-phycoerythrin from Gracilaria lemaneiformis by centrifugal precipitation chromatography.

    PubMed

    Gu, Dongyu; Lazo-Portugal, Rodrigo; Fang, Chen; Wang, Zhantong; Ma, Ying; Knight, Martha; Ito, Yoichiro

    2018-06-15

    Centrifugal precipitation chromatography (CpC) is a powerful chromatographic technique invented in the year 2000 but so far very little applied. The method combines dialysis, counter-current and salting out processes. The separation rotor consists of two identical spiral channels separated by a dialysis membrane (6-8 K MW cut-off) in which the upper channel is eluted with an ammonium sulfate gradient and the lower channel with water, and the mixtures are separated according to their solubility in ammonium sulfate as a chromatographic technique. In the present study, the method was successfully applied for separation and purification of R-phycoerythrin (R-PE), a protein widely used as a fluorescent probe, from the red alga Gracilaria lemaneiformis. The separation was performed with the elution of ammonium sulfate from 50% to 0% in 21.5 h at a flow rate of 0.5 ml/min, while the lower channel was eluted with water at a flow rate of 0.05 ml/min after sample charge, and the column was rotated at 200 rpm. After a single run, the absorbance ratio A 565 /A 280 (a criterion for the purity of R-PE) was increased from 0.5 of the crude to 6.5. The purified R-PE exhibited a typical "three peaks" spectrum with absorbance maximum at 497, 538 and 565 nm. The Native-PAGE showed one single protein band and 20 kDa (subunits α and β) and 30 kDa (subunit γ) can be observed in SDS-PAGE analysis which were consistent with the (αβ) 6 γ subunit composition of R-PE. The results indicated that CpC is an efficient method to obtain protein with the high purity from a complex source. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Recent developments on field gas extraction and sample preparation methods for radiokrypton dating of groundwater

    NASA Astrophysics Data System (ADS)

    Yokochi, Reika

    2016-09-01

    Current and foreseen population growths will lead to an increased demand in freshwater, large quantities of which is stored as groundwater. The ventilation age is crucial to the assessment of groundwater resources, complementing the hydrological model approach based on hydrogeological parameters. Ultra-trace radioactive isotopes of Kr (81 Kr and 85 Kr) possess the ideal physical and chemical properties for groundwater dating. The recent advent of atom trap trace analyses (ATTA) has enabled determination of ultra-trace noble gas radioisotope abundances using 5-10 μ L of pure Kr. Anticipated developments will enable ATTA to analyze radiokrypton isotope abundances at high sample throughput, which necessitates simple and efficient sample preparation techniques that are adaptable to various sample chemistries. Recent developments of field gas extraction devices and simple and rapid Kr separation method at the University of Chicago are presented herein. Two field gas extraction devices optimized for different sampling conditions were recently designed and constructed, aiming at operational simplicity and portability. A newly developed Kr purification system enriches Kr by flowing a sample gas through a moderately cooled (138 K) activated charcoal column, followed by a gentle fractionating desorption. This simple process uses a single adsorbent and separates 99% of the bulk atmospheric gases from Kr without significant loss. The subsequent two stages of gas chromatographic separation and a hot Ti sponge getter further purify the Kr-enriched gas. Abundant CH4 necessitates multiple passages through one of the gas chromatographic separation columns. The presented Kr separation system has a demonstrated capability of extracting Kr with > 90% yield and 99% purity within 75 min from 1.2 to 26.8 L STP of atmospheric air with various concentrations of CH4. The apparatuses have successfully been deployed for sampling in the field and purification of groundwater samples.

  12. Insights into chromatographic separation using core-shell metal-organic frameworks: Size exclusion and polarity effects.

    PubMed

    Qin, Weiwei; Silvestre, Martin E; Kirschhöfer, Frank; Brenner-Weiss, Gerald; Franzreb, Matthias

    2015-09-11

    Porous metal-organic frameworks (MOFs) [Cu3(BTC)2(H2O)3]n (also known as HKUST-1; BTC, benzene-1,3,5-tricarboxylic acid) were synthesized as homogeneous shell onto carboxyl functionalized magnetic microparticles through a liquid phase epitaxy (LPE) process. The as-synthesized core-shell HKUST-1 magnetic microparticles composites were characterized by XRD and SEM, and used as stationary phase in high performance liquid chromatography (HPLC). The effects of the unique properties of MOFs onto the chromatographic performance are demonstrated by the experiments. First, remarkable separation of pyridine and bipyridine is achieved, although both molecules show a strong interaction between the Cu-ions in HKUST-1 and the nitrogen atoms in their heterocyles. The difference can be explained due to size exclusion of bipyridine from the well defined pore structure of crystalline HKUST-1. Second, the enormous variety of possible interactions of sample molecules with the metal ions and linkers within MOFs allows for specifically tailored solid phases for challenging separation tasks. For example, baseline separation of three chloroaniline (CLA) isomers tested can be achieved without the need for gradient elution modes. Along with the experimental HPLC runs, in-depth modelling with a recently developed chromatography modelling software (ChromX) was applied and proofs the software to be a powerful tool for exploring the separation potential of thin MOF films. The pore diffusivity of pyridine and CLA isomers within HKUST-1 are found to be around 2.3×10(-15)m(2)s(-1). While the affinity of HKUST-1 to the tested molecules strongly differs, the maximum capacities are in the same range, with 0.37molL(-1) for pyridine and 0.23molL(-1) for CLA isomers, corresponding to 4.0 and 2.5 molecules per MOF unit cell, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. An improved UHPLC-UV method for separation and quantification of carotenoids in vegetable crops.

    PubMed

    Maurer, Megan M; Mein, Jonathan R; Chaudhuri, Swapan K; Constant, Howard L

    2014-12-15

    Carotenoid identification and quantitation is critical for the development of improved nutrition plant varieties. Industrial analysis of carotenoids is typically carried out on multiple crops with potentially thousands of samples per crop, placing critical needs on speed and broad utility of the analytical methods. Current chromatographic methods for carotenoid analysis have had limited industrial application due to their low throughput, requiring up to 60 min for complete separation of all compounds. We have developed an improved UHPLC-UV method that resolves all major carotenoids found in broccoli (Brassica oleracea L. var. italica), carrot (Daucus carota), corn (Zea mays), and tomato (Solanum lycopersicum). The chromatographic method is completed in 13.5 min allowing for the resolution of the 11 carotenoids of interest, including the structural isomers lutein/zeaxanthin and α-/β-carotene. Additional minor carotenoids have also been separated and identified with this method, demonstrating the utility of this method across major commercial food crops. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Evaluation of the separation performance of polyvinylpyrrolidone as a virtual stationary phase for chromatographic NMR.

    PubMed

    Huang, Shaohua; Wu, Rui; Bai, Zhengwu; Yang, Ying; Li, Suying; Dou, Xiaowei

    2014-09-01

    Polyvinylpyrrolidone (PVP) was used as a virtual stationary phase to separate p-xylene, benzyl alcohol, and p-methylphenol by the chromatographic NMR technique. The effects of concentration and weight-average molecular weight (Mw) of PVP, solvent viscosity, solvent polarity, and sample temperature on the resolution of these components were investigated. It was found that both higher PVP concentration and higher PVP Mw caused the increase of diffusion resolution for the three components. Moreover, the diffusion resolution did not change at viscosity-higher solvents. Moreover, the three components showed different resolution at different solvents. As temperature increased, the diffusion resolution between p-xylene and benzyl alcohol gradually increased, and the one between p-xylene and p-methylphenol slightly increased from 278 to 298 K and then decreased above 298 K. It was also found that the polarity of the analytes played an important role for the separation by affecting the diffusion coefficient. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns.

    PubMed

    Kiplagat, Isaac K; Kubán, Petr; Pelcová, Pavlína; Kubán, Vlastimil

    2010-07-30

    Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any power supply for its operation, except the detection and data acquisition part that is provided by a USB port of a Netbook computer. It is extremely lightweight, its total weight including the Netbook computer is less than 2.5kg and it can be continuously operated for more than 8h. Several parameters of the instrument, such as detection cell design, eluent delivery systems and data treatment were optimized as well as the composition of eluent for non-suppressed ion chromatographic analysis of common inorganic cations (Na(+), NH(4)(+), K(+), Cs(+), Ca(2+), Mg(2+), transition metals). Low conductivity eluents based on weakly complexing organic acids such as tartaric, oxalic or pyridine-2,6-dicarboxylic acids were used with contactless capacitance detection for simultaneous separation of mono- and divalent cations. Separation of Na(+) and NH(4)(+) cations was optimized by addition of 18-crown-6 to the eluent. The best separation of 6 metal cations commonly present in various environmental samples was accomplished in less than 30min using a 1.75mM pyridine-2,6-dicarboxylic acid and 3mM 18-crown-6 eluent with excellent repeatability (below 2%) and detection limits in the low micromolar range. The analysis of field samples is demonstrated; the concentrations of common inorganic cations in river water, mineral water and snow samples were determined.

  16. The importance of mass spectrometric dereplication in fungal secondary metabolite analysis

    PubMed Central

    Nielsen, Kristian F.; Larsen, Thomas O.

    2015-01-01

    Having entered the Genomic Era, it is now evident that the biosynthetic potential of filamentous fungi is much larger than was thought even a decade ago. Fungi harbor many cryptic gene clusters encoding for the biosynthesis of polyketides, non-ribosomal peptides, and terpenoids – which can all undergo extensive modifications by tailoring enzymes – thus potentially providing a large array of products from a single pathway. Elucidating the full chemical profile of a fungal species is a challenging exercise, even with elemental composition provided by high-resolution mass spectrometry (HRMS) used in combination with chemical databases (e.g., AntiBase) to dereplicate known compounds. This has led to a continuous effort to improve chromatographic separation in conjunction with improvement in HRMS detection. Major improvements have also occurred with 2D chromatography, ion-mobility, MS/MS and MS3, stable isotope labeling feeding experiments, classic UV/Vis, and especially automated data-mining and metabolomics software approaches as the sheer amount of data generated is now the major challenge. This review will focus on the development and implementation of dereplication strategies and will highlight the importance of each stage of the process from sample preparation to chromatographic separation and finally toward both manual and more targeted methods for automated dereplication of fungal natural products using state-of-the art MS instrumentation. PMID:25741325

  17. Overcoming bioanalytical challenges in an Onglyza(®) intravenous [(14)C]microdose absolute bioavailability study with accelerator MS.

    PubMed

    Xu, Xiaohui Sophia; Dueker, Stephen R; Christopher, Lisa J; Lohstroh, Pete N; Keung, Chi Fung Anther; Cao, Kai Kevin; Bonacorsi, Samuel J; Cojocaru, Laura; Shen, Jim X; Humphreys, W Griffith; Stouffer, Bruce; Arnold, Mark E

    2012-08-01

    An absolute bioavailability study that utilized an intravenous [(14)C]microdose was conducted for saxagliptin (Onglyza(®)), a marketed drug product for the treatment of Type 2 diabetes mellitus. Concentrations of [(14)C]saxagliptin were determined by accelerator MS (AMS) after protein precipitation, chromatographic separation by UPLC and analyte fraction collection. A series of investigative experiments were conducted to maximize the release of the drug from high-affinity receptors and nonspecific adsorption, and to determine a suitable quantitation range. A technique-appropriate validation demonstrated the accuracy, precision, specificity, stability and recovery of the AMS methodology across the concentration range of 0.025 to 15.0 dpm/ml (disintegration per minute per milliliter), the equivalent of 1.91-1144 pg/ml. Based on the study sample analysis, the mean absolute bioavailability of saxagliptin was 50% in the eight subjects with a CV of 6.6%. Incurred sample reanalysis data fell well within acceptable limits. This study demonstrated that the optimized sample pretreatment and chromatographic separation procedures were critical for the successful implementation of an UPLC plus AMS method for [(14)C]saxagliptin. The use of multiple-point standards are useful, particularly during method development and validation, to evaluate and correct for concentration-dependent recovery, if observed, and to monitor and control process loss and operational variations.

  18. Chromatographic methods for determination of S-substituted cysteine derivatives--a comparative study.

    PubMed

    Kubec, Roman; Dadáková, Eva

    2009-10-09

    A novel HPLC method for determination of a wide variety of S-substituted cysteine derivatives in Allium species has been developed and validated. This method allows simultaneous separation and quantification of S-alk(en)ylcysteine S-oxides, gamma-glutamyl-S-alk(en)ylcysteines and gamma-glutamyl-S-alk(en)ylcysteine S-oxides in a single run. The procedure is based on extraction of these amino acids and dipeptides by methanol, their derivatization by dansyl chloride and subsequent separation by reversed phase HPLC. The main advantages of the new method are simplicity, excellent stability of derivatives, high sensitivity, specificity and the ability to simultaneously analyze the whole range of S-substituted cysteine derivatives. This method was critically compared with other chromatographic procedures used for quantification of S-substituted cysteine derivatives, namely with two other HPLC methods (derivatization by o-phthaldialdehyde/tert-butylthiol and fluorenylmethyl chloroformate), and with determination by gas chromatography or capillary electrophoresis. Major advantages and drawbacks of these analytical procedures are discussed. Employing these various chromatographic methods, the content and relative proportions of individual S-substituted cysteine derivatives were determined in four most frequently consumed alliaceous vegetables (garlic, onion, shallot, and leek).

  19. Supercharging Reagent for Enhanced Liquid Chromatographic Separation and Charging of Sialylated and High-Molecular-Weight Glycopeptides for NanoHPLC-ESI-MS/MS Analysis.

    PubMed

    Lin, Chia-Wei; Haeuptle, Micha A; Aebi, Markus

    2016-09-06

    Recent developments in proteomic techniques have led to the development of mass spectrometry (MS)-based methods to characterize site-specific glycosylation of proteins. However, appropriate analytical tools to characterize acidic and high-molecular-weight (hMW) glycopeptides are still lacking. In this study, we demonstrate that the addition of supercharging reagent, m-nitrobenzyl alcohol (m-NBA), into mobile phases greatly facilitates the analysis of acidic and hMW glycopeptides. Using commercial glycoproteins, we demonstrated that in the presence of m-NBA the charge state of sialylated glycopeptides increased and the chromatographic separation of neutral and acidic glycopeptides revealed a remarkable improvement. Next, we applied this system to the characterization of a glycoconjugate vaccine candidate consisting of a genetically detoxified exotoxin A of Pseudomonas aeruginosa covalently linked to Shigella flexneri type 2a O-antigen (Sf2E) produced by engineered Escherichia coli. The addition of m-NBA, allowed us to identify peptides with glycan chains of unprecedented size, up to 20 repeat units (98 monosaccharides). Our results indicated that incorporation of m-NBA into reversed-phase liquid chromatography (LC) solvents improves sensitivity, charging, and chromatographic resolution for acidic and hMW glycopeptides.

  20. DETERMINATION OF PESTICIDES IN COMPOSITE DIETARY SAMPLES BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY IN THE SELECTED ION MONITORING MODE USING A TEMPERATURE PROGRAMMABLE LARGE VOLUME INJECTOR WITH PRE-SEPARATION COLUMN

    EPA Science Inventory

    Use of a temperature-programmable pre-separation column in the gas chromatographic injection port permits determination of a wide range of semi-volatile pesticides including organochlorines, organophosphates, triazines, and anilines in fatty composite dietary samples while reduci...

  1. Exploring Liquid Sequential Injection Chromatography to Teach Fundamentals of Separation Methods: A Very Fast Analytical Chemistry Experiment

    ERIC Educational Resources Information Center

    Penteado, Jose C.; Masini, Jorge Cesar

    2011-01-01

    Influence of the solvent strength determined by the addition of a mobile-phase organic modifier and pH on chromatographic separation of sorbic acid and vanillin has been investigated by the relatively new technique, liquid sequential injection chromatography (SIC). This technique uses reversed-phase monolithic stationary phase to execute fast…

  2. [HPLC specific chromatogram of Dendrobium officinale].

    PubMed

    Yan, Mei-Qiu; Chen, Su-Hong; Lv, Gui-Yuan; Zhou, Gui-Fen; Liu, Xia

    2013-02-01

    To establish the method of specific chromatogram analysis of ether extract of Dendrobium officinale for identification of D. officinale. Chromatographic separation was carried out at 30 degrees C on an Ultimate C18 column (4.6 mm x 250 mm, 5 microm) eluted with methanol and water containing 0.2% phosphoric acid in a gradient elution at a flow rate of 1.0 mL x min(-1). The detection wavelength was set at 280 nm. The similarity evaluation system for chromatographic fingerprint of NPC (National Pharmacopoeia Committee) was adopted to specific chromatogram construction. The HPLC specific chromatogram of D. officinale was constructed with 6 common specific chromatographic peaks including naringenin as a reference peak. The method shows good precision and repeatability of relative retention time. It can be used to identify D. officinale.

  3. Probabilistic classification method on multi wavelength chromatographic data for photosynthetic pigments identification

    NASA Astrophysics Data System (ADS)

    Prilianti, K. R.; Setiawan, Y.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2014-02-01

    Environmental and health problem caused by artificial colorant encourages the increasing usage of natural colorant nowadays. Natural colorant refers to the colorant that is derivate from living organism or minerals. Extensive research topic has been done to exploit these colorant, but recent data shows that only 0.5% of the wide range of plant pigments in the earth has been exhaustively used. Hence development of the pigment characterization technique is an important consideration. High-performance liquid chromatography (HPLC) is a widely used technique to separate pigments in a mixture and identify it. In former HPLC fingerprinting, pigment characterization was based on a single chromatogram from a fixed wavelength (one dimensional) and discard the information contained at other wavelength. Therefore, two dimensional fingerprints have been proposed to use more chromatographic information. Unfortunately this method leads to the data processing problem due to the size of its data matrix. The other common problem in the chromatogram analysis is the subjectivity of the researcher in recognizing the chromatogram pattern. In this research an automated analysis method of the multi wavelength chromatographic data was proposed. Principal component analysis (PCA) was used to compress the data matrix and Maximum Likelihood (ML) classification was applied to identify the chromatogram pattern of the existing pigments in a mixture. Three photosynthetic pigments were selected to show the proposed method. Those pigments are β-carotene, fucoxanthin and zeaxanthin. The result suggests that the method could well inform the existence of the pigments in a particular mixture. A simple computer application was also developed to facilitate real time analysis. Input of the application is multi wavelength chromatographic data matrix and the output is information about the existence of the three pigments.

  4. Chromatographic separation of fructose from date syrup.

    PubMed

    Al Eid, Salah M

    2006-01-01

    The objective of this study is to provide a process for separating fructose from a mixture of sugars containing essentially fructose and glucose, obtained from date palm fruits. The extraction procedure of date syrup from fresh dates gave a yield of 86.5% solids after vacuum drying. A process for separating fructose from an aqueous solution of date syrup involved adding the date syrup solutions (20, 30 and 40% by weight) to a chromatographic column filled with Dowex polystyrene strong cation exchange gel matrix resin Ca2 + and divinylbenzene, a functional group, sulfonic acid, particle size 320 microm, with a flow rate of 0.025 and 0.05 bed volume/min, under 30 and 70 degrees C column temperature. After the date sugar solution batch, a calculated quantity of water was added to the column. Glucose was retained by the resin more weakly than fructose and proceeded faster into the water batch flowing ahead. Three fractions were collected: a glucose-rich fraction, a return fraction, and a fructose-rich fraction. The return fraction is based on when the peaks of fructose and glucose were reached, which could be determined by means of an analyzer (polarimeter) based on the property of glucose and fructose solutions to turn the polarization level of polarized light. A high yield of fructose is obtained at 70 degrees C column temperature with a flow rate of 0.025 bed volume/min and date syrup solution containing 40% sugar concentration. The low recovery by weight obtained using date syrup solutions having a sugar concentration of 20 and 30%, encourages the use of a concentration of 40%. However, with the 40% date syrup supply the average concentrations of glucose and fructose in the return fractions were more than 40%, which can be used for diluting the thick date syrup solution extracted from dates.

  5. A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas.

    PubMed

    Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J; Lang, Walter

    2017-10-07

    Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system.

  6. CE of phytosiderophores and related metal species in plants.

    PubMed

    Xuan, Yue; Scheuermann, Enrico B; Meda, Anderson R; Jacob, Peter; von Wirén, Nicolaus; Weber, Günther

    2007-10-01

    Phytosiderophores (PS) and the closely related substance nicotianamine (NA) are key substances in metal uptake into graminaceous plants. Here, the CE separation of these substances and related metal species is demonstrated. In particular, the three PS 2'-deoxymugineic acid (DMA), mugineic acid (MA), and 3-epi-hydroxymugineic acid (epi-HMA), and NA, are separated using MES/Tris buffer at pH 7.3. Moreover, three Fe(III) species of the different PS are separated without any stability problems, which are often present in chromatographic analyses. Also divalent metal species of Cu, Ni, and Zn with the ligands DMA and NA are separated with the same method. By using a special, zwitterionic CE capillary, even the separation of two isomeric Fe(III) chelates with the ligand ethylenediamine-N,N'-bis(o-hydroxyphenyl)acetic acid (EDDHA) is possible (i.e., meso-Fe(III)-EDDHA and rac-Fe(III)-EDDHA), and for fast separations of NA and respective divalent and trivalent metal species, a polymer CE microchip with suppressed EOF is described. The proposed CE method is applicable to real plant samples, and enables to detect changes of metal species (Cu-DMA, Ni-NA), which are directly correlated to biological processes.

  7. Evaluation of reversible interconversion in comprehensive two-dimensional gas chromatography using enantioselective columns in first and second dimensions.

    PubMed

    Kröger, Sabrina; Wong, Yong Foo; Chin, Sung-Tong; Grant, Jacob; Lupton, David; Marriott, Philip J

    2015-07-24

    The reversible molecular interconversion behaviour of a synthesised oxime (2-phenylpropanaldehyde oxime; (C6H5)CH(CH3)CHN(OH)) was investigated by both, single dimensional gas chromatography (1D GC) and comprehensive two-dimensional gas chromatography (GC×GC). Previous studies on small molecular weight oximes were extended to this larger aromatic oxime (molar mass 149.19gmol(-1)) with interest in the extent of interconversion, enantioselective resolution, and retention time. On a polyethylene glycol (PEG; wax-type) column, a characteristic interconversion zone between two antipodes of E and Z isomers was formed by molecules which have undergone isomerisation on the column (E⇌Z). The extent of interconversion was investigated by varying chromatographic conditions (oven temperature and carrier flow rate) to understand the nature of the behaviour observed. The extent of interconversion was negligible in both enantioselective and methyl-phenylpolysiloxane phase-columns, correlating with the low polarity of the stationary phase. In order to obtain isomerisation along with enantio-resolution, a wax-type and an enantioselective column were coupled in either enantioselective-wax or wax-enantioselective order. The most appropriate column arrangement was selected for study by using a GC×GC experiment with either a wax-phase or phenyl-methylpolysiloxane phase as (2)D column. In addition to evaluation of these fast elution columns, a long narrow-bore enantioselective column (10m) was introduced as (2)D, providing an enantioselective-PEG (coupled-column ensemble: (1)D1+(1)D2)×enantioselective ((2)D) column combination. In this instance, the (1)D1 enantioselective column provides enantiomeric separation of the corresponding enantiomers ((R) and (S)) of (E)- and (Z)-2-phenylpropanaldehyde oxime, followed by E/Z isomerisation in the coupled (1)D2 PEG (reactor) column. The resulting chromatographic interconversion region was modulated and separated into either E/Z isomers (achiral (2)D column) or into the respective (R) and (S) enantiomers of the E/Z isomers when using a (2)D enantioselective column. With this arrangement, the isomers underneath the broad interconversion plateau in 1D elution profiles, including the enantiomers, could be resolved, illuminating salient features and understanding of the molecular reversible process of the interconverting molecules during the chromatographic elution. The two-dimensional patterns (contour plots), resulting from the combination of interconversion process and chiral separation, are discussed phenomenologically. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Detection of dehalogenation impurities in organohalogenated pharmaceuticals by UHPLC-DAD-HRESIMS.

    PubMed

    Regalado, Erik L; Dermenjian, Renee K; Joyce, Leo A; Welch, Christopher J

    2014-04-01

    The presence of dehalogenated impurities is often observed in halogen-containing pharmaceuticals, and can present a difficult analytical challenge, as the chromatographic behavior of the halogenated drug and the hydrogen-containing analog can be quite similar. In this study we describe the chromatographic separation and unambiguous identification of dehalogenation impurities or associated isomers in organohalogenated pharmaceuticals using UHPLC with a pentafluorophenyl column coupled with diode-array and high resolution electrospray ionization mass spectrometry detection (UHPLC-DAD-HRESIMS). Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Simple method for the extraction and reversed-phase high-performance liquid chromatographic analysis of carotenoid pigments from red yeasts (Basidiomycota, Fungi).

    PubMed

    Weber, Roland W S; Anke, Heidrun; Davoli, Paolo

    2007-03-23

    A simple method for the extraction of carotenoid pigments from frozen wet cells of red yeasts (Basidiomycota) and their analysis by reversed-phase HPLC using a C(18) column and a water/acetone solvent system is described. Typical red yeast carotenoids belonging to an oxidative series from the monocyclic gamma-carotene to 2-hydroxytorularhodin and from the bicyclic beta-carotene to astaxanthin were separated. Pigment identity was confirmed by LC-atmospheric pressure chemical ionisation (APCI) mass spectrometry using similar chromatographic conditions.

  10. High-pressure liquid chromatographic analysis of pramoxine hydrochloride in high lipoid aerosol foam dosage form.

    PubMed

    Weinberger, R; Mann, B; Posluszny, J

    1980-04-01

    A rapid and quantitative method for the determination of pramoxine hydrochloride by high-pressure liquid chromatography is presented. The drug is extracted as the salt from a preparation with a high lipoid composition by partitioning it to the aqueous phase of an ether-methanol-water-acetic acid system. The extract is chromatographed on an octadecylsilane bonded packing with a methanol-water-acetic acid-methanesulfonic acid mobile phase. The time required for each separation is approximately 6 min. Analytical recoveries of 100.4 +/- 1.5% were obtained.

  11. [Gas chromatographic isolation of chloropicrin in drinking water].

    PubMed

    Malysheva, A G; Sotnikov, E E; Moskovkin, A S; Kamenetskaia, D B

    2004-01-01

    Gas chromatographic method has been developed to identify chloropicrin in the drinking water, which is based on its separation from water by statistic gas extraction and on the analysis of equilibrium vapor phase on a capillary column with electron-capture and nitrogen-phosphorus detectors connected in series. The method allows chloropicrin to be detected at the level of 5 mg/dm3 with a total measurement error of +/- 10% at a confidence probability of 0.95. The paper shows that the sensitivity of identification can be significantly increased.

  12. High-performance liquid chromatographic characterization of some medical plant extracts used in cosmetic formulas.

    PubMed

    Schulz, H; Albroscheit, G

    1988-06-17

    Rapid and reliable methods are presented for the characterization of biologically active and/or characteristic constituents in aqueous extracts of Hamamelis virginiana, Matricaria chamomilla, Achillea millefolium, Thymus vulgaris, Althaea officinalis and Cinchonia spp. Prior to high-performance liquid chromatographic (HPLC) separation a clean-up step was performed using a solid-phase extraction system. The purified extracts were analysed by HPLC coupled with a diode-array detector and a fluorescence detector. In some instances, previously unreported components of the aqueous plant extracts were found.

  13. Analytical Challenges in Biotechnology.

    ERIC Educational Resources Information Center

    Glajch, Joseph L.

    1986-01-01

    Highlights five major analytical areas (electrophoresis, immunoassay, chromatographic separations, protein and DNA sequencing, and molecular structures determination) and discusses how analytical chemistry could further improve these techniques and thereby have a major impact on biotechnology. (JN)

  14. Characterization of multiblock copolymers by chromatographic techniques.

    PubMed

    N'Goma, Patrick Yoba; Radke, Wolfgang; Malz, Frank; Ziegler, Hans Jörg; Zierke, Michael; Behl, Marc; Lendlein, Andreas

    2011-02-01

    Multiblock copolymers (MBC) composed of blocks of poly(1,4-dioxanone) (PPDO) and poly(e-caprolactone) (PCL) were investigated in order to gain information on the extend of chemical heterogeneity of the samples. A gradient chromatographic method was established allowing separation of purely PPDO- from purely PCL-containing chains. Application of the gradient to MBC made of PPDO- and PCL-diols connected by trimethylhexamethylene diisocyanate (TMDI) resulted in two well separated peaks which were analyzed by means of FTIR, 1H-NMR and pyrolysis GC-MS. It was shown that the first peak was composed to a large extent of PPDO and only lower amounts of PCL were incorporated. Conversely, the second peak consisted predominantly of PCL with only a minor fraction of PPDO. Thus, the MBCs having PPDO and PCL segments show an unexpected broad chemical heterogeneity.

  15. Isolation of oxidative degradation products of atorvastatin with supercritical fluid chromatography.

    PubMed

    Klobčar, Slavko; Prosen, Helena

    2015-12-01

    The isolation of four oxidative degradation products of atorvastatin using preparative high-performance liquid chromatography applying at least two chromatographic steps is known from the literature. In this paper it is shown that the same four impurities could be isolated from similarly prepared mixtures in only one step using supercritical fluid chromatography. The methods for separation were developed and optimized. The preparation of the mixtures was altered in such a way as to enhance the concentration of desired impurities. Appropriate solvents were applied for collection of separated impurities in order to prevent degradation. The structures of the isolated impurities were confirmed and their purity determined. The preparative supercritical fluid chromatography has proven to be superior to preparative HPLC regarding achieved purity of standards applying fewer chromatographic as well as isolation steps. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems.

    PubMed

    Shinomiya, Kazufusa; Sato, Kazuki; Yoshida, Kazunori; Tokura, Koji; Maruyama, Hiroshi; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2013-12-27

    A new design of universal high-speed counter-current chromatograph (HSCCC) was fabricated in our laboratory. It holds a set of four column holders symmetrically around the rotary frame at a distance of 11.2cm from the central axis. By engaging the stationary gear on the central axis of the centrifuge to the planetary gears on the column holder shaft through a set of idle gears, two pairs of diagonally located column holders simultaneously rotate about their own axes in the opposite directions: one forward (type-J planetary motion) and the other backward (type-I planetary motion) each synchronously with the revolution. Using the eccentric coil assembly, partition efficiencies produced by these two planetary motions were compared on the separation of two different types of sugar derivatives (4-methylumbelliferyl and 5-bromo-4-chloro-3-indoxyl sugar derivatives) using organic-aqueous two-phase solvent systems composed of n-hexane/ethyl acetate/1-butanol/methanol/water and aqueous 0.1M sodium tetraborate, respectively. With lower phase mobile, better peak resolution was obtained by the type-J forward rotation for both samples probably due to higher retention of the stationary phase. With upper phase mobile, however, similar peak resolutions were obtained between these two planetary motions for both sugar derivatives. The overall results indicate that the present universal HSCCC is useful for counter-current chromatographic separation since each planetary motion has its specific applications: e.g., vortex CCC by the type-I planetary motion and HSCCC by the type-J planetary motion both for separation of various natural and synthetic products. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Detection of monohydroxylated polycyclic aromatic hydrocarbons in urine and particulate matter using LC separations coupled with integrated SPE and fluorescence detection or coupled with high-resolution time-of-flight mass spectrometry.

    PubMed

    Lintelmann, Jutta; Wu, Xiao; Kuhn, Evelyn; Ritter, Sebastian; Schmidt, Claudia; Zimmermann, Ralf

    2018-05-01

    A high-performance liquid chromatographic (HPLC) method with integrated solid-phase extraction for the determination of 1-hydroxypyrene and 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid-phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core-shell column using a methanol gradient. For quantification, time-programmed fluorescence detection was used. Matrix-dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC-fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra-high-performance liquid chromatography pentafluorophenyl core-shell column and coupled to a high-resolution time-of-flight mass spectrometer (HR-TOF-MS). The resulting method was used to demonstrate the applicability of LC-HR-TOF-MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Multiple-channel ultra-violet absorbance detector for two-dimensional chromatographic separations.

    PubMed

    Lynch, Kyle B; Yang, Yu; Ren, Jiangtao; Liu, Shaorong

    2018-05-01

    In recent years, much research has gone into developing online comprehensive two-dimensional liquid chromatographic systems allowing for high peak capacities in comparable separation times to that of one-dimensional liquid chromatographic systems. However, the speed requirements in the second dimension (2nd-D) still remain one challenge for complex biological samples due to the current configuration of two column/two detector systems. Utilization of multiple 2nd-D columns can mitigate this challenge. To adapt this approach, we need a multiple channel detector. Here we develop a versatile multichannel ultraviolet (UV) light absorbance detector that is capable of simultaneously monitoring separations in 12 columns. The detector consists of a deuterium lighthouse, a flow cell assembly (a 13-channel flow cell fitted with a 13-photodiode-detection system), and a data acquisition and monitoring terminal. Through the use of a custom high optical quality furcated fiber to improve light transmission, precise machining of a flow cell to reduce background stray light through precision alignment, and sensitive electronic circuitry to reduce electronic noise through an active low pass filter, the background noise level is measured in the tens of µAU. We obtain a linear dynamic range of close to three orders of magnitude. Compared to a commercialized multichannel UV light absorbance detector like the Waters 2488 UV/Vis, our device provides an increase in channel detection while residing within the same noise region and linear range. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Validated Chromatographic Methods for the Analysis of Two Binary Mixtures Containing Pyridoxine Hydrochloride.

    PubMed

    Habib, Neven M; Abdelrahman, Maha M; Abdelwhab, Nada S; Ali, Nourudin W

    2017-03-01

    Accurate and precise TLC-densitometric and HPLC-diode-array detector (DAD) methods have been developed and validated to resolve two binary mixtures containing pyridoxine hydrochloride (PYH) with either cyclizine hydrochloride (CYH) or meclizine hydrochloride (MEH). In the developed TLC-densitometric method, chromatographic separation of the three studied drugs was carried out on silica gel 60 F254 plates using a developing system containing methylene chloride + acetone + methanol (7 + 1 + 0.5, v/v/v) scanning separated bands at 220 nm. Beer-Lambert law was obeyed in the ranges of 0.2-5, 0.2-4, and 0.2-4 µg/band for PYH, CYH, and MEH, respectively. On the other hand, the developed HPLC-DAD method depended on chromatographic separation on a Zorbax Eclipse C18 column using methanol-KH2PO4 (0.05 M; 90 + 10, v/v; pH 5, with H3PO4 and KOH) as the mobile phase, a flow rate of 1 mL/min, and UV scanning at 220 nm. A linear relationship was obtained between the integrated peak area and the concentration in the ranges of 10-50, 10-50, and 7-50 µg/mL for PYH, CYH, and MEH, respectively. The proposed methods were successfully applied for the determination of the cited drugs in their pharmaceutical formulations. Statistical comparison with the reported methods using Student's t- and F-tests found there were no significant differences between the proposed and reported methods for accuracy and precision.

  20. Room temperature ionic liquids: new GC stationary phases with a novel selectivity for flavor and fragrance analyses.

    PubMed

    Cagliero, Cecilia; Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Sgorbini, Barbara; Rubiolo, Patrizia

    2012-12-14

    Ionic liquids (ILs) are of great interest as moderately polar to polar stationary phases for GC, because their selectivity differs markedly from that of conventionally used phases. In the flavor, fragrance and essential oil fields, analysts often deal with complex mixtures of compounds having similar structural and physical characteristics (e.g., mono- and sesquiterpenoids), therefore requiring an interactive combination between chromatographic and mass spectral data for correct identification. New GC stationary phases with different selectivity must therefore be continually tested. Performance and evolution over time of commercially available IL columns versus those commonly used in these fields are here evaluated, mainly in view of their routine use. Chromatographic and separative properties (efficiency, separation capability, inertness and/or activity) of commercially available IL columns were compared to those of columns coated with 5% phenyl-95% methylpolysiloxane, 14% cyanopropyl-86% polysiloxane, and polyethylene glycol, on different complexity samples, including standard mixtures of volatile suspected allergens and pesticides, and cornmint and vetiver essential oils. The results show that IL columns can successfully be used for a wide range of applications characteristic of these fields, mainly because of their unusual selectivity, in particular when separations based on functional groups are required. Moreover, the latest generation of IL columns (IL61 and IL60) presents chromatographic performance comparable to or only slightly lower than that of the conventional columns routinely used in these fields. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Evolving trends in mAb production processes

    PubMed Central

    Wolfe, Leslie S.; Mostafa, Sigma S.; Norman, Carnley

    2017-01-01

    Abstract Monoclonal antibodies (mAbs) have established themselves as the leading biopharmaceutical therapeutic modality. The establishment of robust manufacturing platforms are key for antibody drug discovery efforts to seamlessly translate into clinical and commercial successes. Several drivers are influencing the design of mAb manufacturing processes. The advent of biosimilars is driving a desire to achieve lower cost of goods and globalize biologics manufacturing. High titers are now routinely achieved for mAbs in mammalian cell culture. These drivers have resulted in significant evolution in process platform approaches. Additionally, several new trends in bioprocessing have arisen in keeping with these needs. These include the consideration of alternative expression systems, continuous biomanufacturing and non‐chromatographic separation formats. This paper discusses these drivers in the context of the kinds of changes they are driving in mAb production processes. PMID:29313024

  2. High-performance liquid chromatographic analysis of as-synthesised N,N'-dimethylformamide-stabilised gold nanoclusters product

    NASA Astrophysics Data System (ADS)

    Xie, Shunping; Paau, Man Chin; Zhang, Yan; Shuang, Shaomin; Chan, Wan; Choi, Martin M. F.

    2012-08-01

    Reverse-phase high-performance liquid chromatographic (RP-HPLC) separation and analysis of polydisperse water-soluble gold nanoclusters (AuNCs) stabilised with N,N'-dimethylformamide (DMF) were investigated. Under optimal elution gradient conditions, the separation of DMF-AuNCs was monitored by absorption and fluorescence spectroscopy. The UV-vis spectral characteristics of the separated DMF-AuNCs have been captured and they do not possess distinct surface plasmon resonance bands, indicating that all DMF-AuNCs are small AuNCs. The photoluminescence emission spectra of the separated DMF-AuNCs are in the blue-light region. Moreover, cationic DMF-AuNCs are for the first time identified by ion chromatography. Our proposed RP-HPLC methodology has been successfully applied to separate AuNCs of various Au atoms as well as DMF-stabilised ligands. Finally, the composition of the separated DMF-AuNCs was confirmed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry and electrospray ionisation mass spectrometry, proving that the as-synthesised DMF-AuNCs product consists of Au10+, Au10, Au11, Au12, Au13, and Au14 NCs stabilised with various numbers of DMF ligands.Reverse-phase high-performance liquid chromatographic (RP-HPLC) separation and analysis of polydisperse water-soluble gold nanoclusters (AuNCs) stabilised with N,N'-dimethylformamide (DMF) were investigated. Under optimal elution gradient conditions, the separation of DMF-AuNCs was monitored by absorption and fluorescence spectroscopy. The UV-vis spectral characteristics of the separated DMF-AuNCs have been captured and they do not possess distinct surface plasmon resonance bands, indicating that all DMF-AuNCs are small AuNCs. The photoluminescence emission spectra of the separated DMF-AuNCs are in the blue-light region. Moreover, cationic DMF-AuNCs are for the first time identified by ion chromatography. Our proposed RP-HPLC methodology has been successfully applied to separate AuNCs of various Au atoms as well as DMF-stabilised ligands. Finally, the composition of the separated DMF-AuNCs was confirmed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry and electrospray ionisation mass spectrometry, proving that the as-synthesised DMF-AuNCs product consists of Au10+, Au10, Au11, Au12, Au13, and Au14 NCs stabilised with various numbers of DMF ligands. This article was submitted as part of a Themed Issue on metallic clusters. Other papers on this topic can be found in issue 14 of vol. 4 (2012). This issue can be found from the Nanoscale homepage [http://www.rsc.org/nanoscale].

  3. ELECTRICALLY ACTUATED, PRESSURE-DRIVEN LIQUID CHROMATOGRAPHY SEPARATIONS IN MICROFABRICATED DEVICES

    PubMed Central

    Fuentes, Hernan V.; Woolley, Adam T.

    2012-01-01

    Electrolysis-based micropumps integrated with microfluidic channels in micromachined glass substrates are presented. Photolithography combined with wet chemical etching and thermal bonding enabled the fabrication of multi-layer devices containing electrically actuated micropumps interfaced with sample and mobile phase reservoirs. A stationary phase was deposited on the microchannel walls by coating with 10% (w/w) chlorodimethyloctadecylsilane in toluene. Pressure-balanced injection was implemented by controlling the electrolysis time and voltage applied in the two independent micropumps. Current fluctuations in the micropumps due to the stochastic formation of bubbles on the electrode surfaces were determined to be the main cause of variation between separations. On-chip electrochemical pumping enabled the loading of pL samples with no dead volume between injection and separation. A mobile phase composed of 70% acetonitrile and 30% 50 mM acetate buffer (pH 5.45) was used for the chromatographic separation of three fluorescently labeled amino acids in <40 s with an efficiency of >3000 theoretical plates in a 2.5-cm-long channel. Our results demonstrate the potential of electrochemical micropumps integrated with microchannels to perform rapid chromatographic separations in a microfabricated platform. Importantly, these devices represent a significant step toward the development of miniaturized and fully integrated liquid chromatography systems. PMID:17960281

  4. Electrically actuated, pressure-driven liquid chromatography separations in microfabricated devices.

    PubMed

    Fuentes, Hernan V; Woolley, Adam T

    2007-11-01

    Electrolysis-based micropumps integrated with microfluidic channels in micromachined glass substrates are presented. Photolithography combined with wet chemical etching and thermal bonding enabled the fabrication of multi-layer devices containing electrically actuated micropumps interfaced with sample and mobile phase reservoirs. A stationary phase was deposited on the microchannel walls by coating with 10% (w/w) chlorodimethyloctadecylsilane in toluene. Pressure-balanced injection was implemented by controlling the electrolysis time and voltage applied in the two independent micropumps. Current fluctuations in the micropumps due to the stochastic formation of bubbles on the electrode surfaces were determined to be the main cause of variation between separations. On-chip electrochemical pumping enabled the loading of pL samples with no dead volume between injection and separation. A mobile phase composed of 70% acetonitrile and 30% 50 mM acetate buffer (pH 5.45) was used for the chromatographic separation of three fluorescently labeled amino acids in <40 s with an efficiency of >3000 theoretical plates in a 2.5 cm-long channel. Our results demonstrate the potential of electrochemical micropumps integrated with microchannels to perform rapid chromatographic separations in a microfabricated platform. Importantly, these devices represent a significant step toward the development of miniaturized and fully integrated liquid chromatography systems.

  5. Development of an analytical method for separation of phenolic acids by ultra-performance convergence chromatography (UPC2) using a column packed with a sub-2-μm particle.

    PubMed

    Jiang, Hai; Yang, Liu; Xing, Xudong; Yan, Meiling; Guo, Xinyue; Yang, Bingyou; Wang, Qiu-Hong; Kuang, Hai-Xue

    2018-05-10

    Phenolic acids are important active components of certain Traditional Chinese Medicines (TCM) and have a wide range of biological effects. Separation and purification of phenolic acids remains challenging due to difficulties with quality control using existing chromatographic methods The purpose of this study was to compare the effects of different chromatographic columns and conditions for the separation of phenolic acids. The BEH column was determined to be optimal, providing efficient separation in the shortest time (17.00 min) using gradient elution with carbon dioxide as the mobile phase, methanol/acetonitrile (70:30, v/v) with 1% TFA as the modifier, and a flow rate of 0.8 mL/min. Good peak shapes were obtained, and the peak asymmetry values were close to 1.00 for all phenolic acids. The resolution was more than 2.83 for all separated peaks. The developed method was subsequently applied to the determination of phenolic acids in Xanthii Fructus. These results are beneficial for quality control and standardization of herbal drugs using UPC 2 , providing an efficient, rapid and environmentally friendly scientific basis for future analysis of phenolic acids. Copyright © 2018. Published by Elsevier B.V.

  6. Indirect ultraviolet detection of alkaline earth metal ions using an imidazolium ionic liquid as an ultraviolet absorption reagent in ion chromatography.

    PubMed

    Liu, Yong-Qiang; Yu, Hong

    2017-04-01

    A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg 2+ , Ca 2+ , and Sr 2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg 2+ , Ca 2+ , and Sr 2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg 2+ , Ca 2+ , and Sr 2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Chiral magnetic microspheres purified by centrifugal field flow fractionation and microspheres magnetic chiral chromatography for benzoin racemate separation.

    PubMed

    Tian, Ailin; Qi, Jing; Liu, Yating; Wang, Fengkang; Ito, Yoichiro; Wei, Yun

    2013-08-30

    Separation of enantiomers still remains a challenge due to their identical physical and chemical properties in a chiral environment, and the research on specific chiral selector along with separation techniques continues to be conducted to resolve individual enantiomers. In our laboratory the promising magnetic chiral microspheres Fe3O4@SiO2@cellulose-2, 3-bis (3,5-dimethylphenylcarbamate) have been developed to facilitate the resolution using both its magnetic property and chiral recognition ability. In our present studies this magnetic chiral selector was first purified by centrifuge field flow fractionation, and then used to separate benzoin racemate by a chromatographic method. Uniform-sized and masking-impurity-removed magnetic chiral selector was first obtained by field flow fractionation with ethanol through a spiral column mounted on the type-J planetary centrifuge, and using the purified magnetic chiral selector, the final chromatographic separation of benzoin racemate was successfully performed by eluting with ethanol through a coiled tube (wound around the cylindrical magnet to retain the magnetic chiral selector as a stationary phase) submerged in dry ice. In addition, an external magnetic field facilitates the recycling of the magnetic chiral selector. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Isotopic separation of acetaldehyde and methanol from their deuterated isotopologues on a porous layer open tubular column allows quantification by stable isotope dilution without mass spectrometric detection.

    PubMed

    Schmarr, Hans-Georg; Wacker, Michael; Mathes, Maximilian

    2017-01-20

    An isotopic separation of acetaldehyde and acetaldehyde-2,2,2-d3 was achieved in a temperature programmed run on a porous layer open tubular (PLOT) capillary column coated with particles of divinylbenzene ethylene glycol/dimethylacrylate (Rt ® -U-BOND). This is the prerequisite for the development of quantitative analytical methods based on a stable isotope dilution assay (SIDA) without a mass spectrometric detection (non-MS SIDA). For routine analysis a flame ionization detector (FID) can thus be applied as a robust and low-cost alternative. In a preliminary study, static headspace extraction and gas chromatographic separation (HS-GC-FID) of acetaldehyde in aqueous solutions was shown as an application. Good linearity was obtained in a calibration range from 0.4 to 40mgL -1 , with peak integration benefitting from the inverse isotope effect encountered on the specific porous polymer. Furthermore, separation of methanol and deuterated methanol (d3) could also be achieved under the same chromatographic conditions. The achieved isotopic separation of these important volatile compounds now allows non-MS SIDA-based methods that are still to be developed. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Size exclusion chromatographic analysis of refuse-derived fuel for mycotoxins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bicking, M.K.; Kniseley, R.N.

    1980-11-01

    A Styragel packing material is characterized in several solvent systems by using a series of test solutes and mycotoxins. Differences in interpretation with other work are discussed. Three different separation modes are generated on one stationary phase. An improved separation of mycotoxins from a compilcated matrix results by simultaneously using size exclusion and liquid-liquid partitioning. 4 figures, 3 tables.

  10. Critical conditions of polymer adsorption and chromatography on non-porous substrates.

    PubMed

    Cimino, Richard T; Rasmussen, Christopher J; Brun, Yefim; Neimark, Alexander V

    2016-07-15

    We present a novel thermodynamic theory and Monte Carlo simulation model for adsorption of macromolecules to solid surfaces that is applied for calculating the chain partition during separation on chromatographic columns packed with non-porous particles. We show that similarly to polymer separation on porous substrates, it is possible to attain three chromatographic modes: size exclusion chromatography at very weak or no adsorption, liquid adsorption chromatography when adsorption effects prevail, and liquid chromatography at critical conditions that occurs at the critical point of adsorption. The main attention is paid to the analysis of the critical conditions, at which the retention is chain length independent. The theoretical results are verified with specially designed experiments on isocratic separation of linear polystyrenes on a column packed with non-porous particles at various solvent compositions. Without invoking any adjustable parameters related to the column and particle geometry, we describe quantitatively the observed transition between the size exclusion and adsorption separation regimes upon the variation of solvent composition, with the intermediate mode occurring at a well-defined critical point of adsorption. A relationship is established between the experimental solvent composition and the effective adsorption potential used in model simulations. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Determination of volatile compounds in cider apple juices using a covalently bonded ionic liquid coating as the stationary phase in gas chromatography.

    PubMed

    Pello-Palma, Jairo; González-Álvarez, Jaime; Gutiérrez-Álvarez, María Dolores; Dapena de la Fuente, Enrique; Mangas-Alonso, Juan José; Méndez-Sánchez, Daniel; Gotor-Fernández, Vicente; Arias-Abrodo, Pilar

    2017-04-01

    A chromatographic method for the separation of volatile compounds in Asturian cider apple juices has been developed. For this separation purpose, a monocationic imidazolium-based ionic liquid bearing a reactive terminal iodine atom was synthesized by a quaternization-anion exchange chemical sequence. Next, the gas chromatography (GC) stationary phase was prepared by covalently linking the imidazolium monolith to the reactive silanol groups of the inner capillary wall at 70 °C. This coated GC column exhibited good thermal stability (290 °C), as well as good efficiency (2000 plates/m) in the separation of volatile compounds from Asturian apple cider juices, and was characterized using the Abraham solvation parameter model. The intra-day and inter-day precision of the chromatographic method was evaluated, obtaining relative standard deviations from 3.7 to 12.9% and from 7.4 to 18.0%, respectively. Furthermore, recoveries from 82.5 to 122% were achieved. Graphical Abstract Covalent bonding of an ionic liquid to inner column wall led to a great improvement of the separation efficiencies of stationary phases in gas chromatography.

  12. [[Chiral separation of five arylpropionic acid drugs and determination of their enantiomers in pharmaceutical preparations by reversed-phase high performance liquid chromatography with cellulose-tris-(4-methylbenzoate) stationary phase

    PubMed

    Luo, An; Wan, Qiang; Fan, Huajun; Chen, Zhi; Wu, Xuehao; Huang, Xiaowen; Zang, Linquan

    2014-09-01

    Chromatographic behaviors for enantiomeric separation of arylpropionic acid drugs were systematically developed by reversed phase-high performance liquid chromatography (RP-HPLC) using cellulose-tris-(4-methylbenzoate) (CTMB) as chiral stationary phase (CSP). The effects of the composition of the mobile phase, additives and temperature on chiral separation of flurbiprofen, pranoprofen, naproxen, ibuprofen and loxoprofen were further investigated. The enantiomers had been successfully separated on CSP of CTMB by the mobile phase of methanol-0.1% (v/v) formic acid except naproxen by acetonitrile-0.1% (v/v) formic acid at 25 °C. The mechanisms of the racemic resolution for the above mentioned five drugs are discussed thermodynamically and structurally. The resolutions between respective enantiomers for arylpropionic acid drugs on CTMB had significant differences due to their chromatographic behaviors. The order of resolutions ranked pranoprofen, loxoprofen, flurbiprofen, ibuprofen and naproxen. The method established has been successfully applied to the determination of the enantiomers of the five drugs in commercial preparations under the optimized conditions. It proved that the method is simple, reliable and accurate.

  13. A volatile organics concentrator for use in monitoring Space Station water quality

    NASA Technical Reports Server (NTRS)

    Ehntholt, Daniel J.; Bodek, Itamar; Valentine, James R.; Trabanino, Rudy; Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    The process used to identify, select, and design an approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment is discerned. The trade analysis leading to the recommended volatile organics concentrator (VOC) concept to be tested in a breadboard device is presented. The system covers the areas of gases, volatile separation from water, and water removal/gas chromatograph/mass spectrometer interface. Five options for potential use in the VOC and GC/MS system are identified and ranked, and also nine options are presented for separation of volatiles from the water phase. Seven options for use in the water removal/GC column and MS interface are also identified and included in the overall considerations. A final overall recommendation for breadboard VOC testing is given.

  14. Binary chromatographic data and estimation of adsorbent porosities. [data for system n-heptane/n-pentane

    NASA Technical Reports Server (NTRS)

    Meisch, A. J.

    1972-01-01

    Data for the system n-pentane/n-heptane on porous Chromosorb-102 adsorbent were obtained at 150, 175, and 200 C for mixtures containing zero to 100% n-pentane by weight. Prior results showing limitations on superposition of pure component data to predict multicomponent chromatograms were verified. The thermodynamic parameter MR0 was found to be a linear function of sample composition. A nonporous adsorbent failed to separate the system because of large input sample dispersions. A proposed automated data processing scheme involving magnetic tape recording of the detector signals and processing by a minicomputer was rejected because of resolution limitations of the available a/d converters. Preliminary data on porosity and pore size distributions of the adsorbents were obtained.

  15. Separation and determination of synthetic impurities of difloxacin by reversed-phase high-performance liquid chromatography.

    PubMed

    Rao, R Nageswara; Nagaraju, V

    2004-11-19

    A simple and rapid reversed-phase high-performance liquid chromatographic method for separation and determination of process-related impurities of difloxacin (DFL) was developed. The separation was achieved on a reversed-phase C(18) column using methanol-water-acetic acid (78:21.9:0.1, v/v/v) as a mobile solvent at a flow rate of 1.0 ml/min at 28 degrees C using UV detection at 230 nm. It was linear over a range of 0.03 x 10(-6) to 1.60 x 10(-6)g for process related impurities and 0.05 x 10(-6) to 2.40 x 10(-6)g for difloxacin. The detection limits were 0.009 x 10(-6) to 0.024 x 10(-6)g for all the compounds examined. The recoveries were found to be in the range of 97.6-102.0% for impurities as well as difloxacin. The precision and robustness of the method were evaluated. It was used for not only quality assurance, but also monitoring the synthetic reactions involved in the process development work of difloxacin. The method was found to be specific, precise and reliable for the determination of unreacted levels of raw materials, intermediates in the reaction mixtures and the finished products of difloxacin.

  16. Rapid Analysis of Microalgal Triacylglycerols with Direct-Infusion Mass Spectrometry

    DOE PAGES

    Christensen, Earl; Sudasinghe, Nilusha; Dandamudi, Kodanda Phani Raj; ...

    2015-09-01

    Cultivation of microalgae has the potential to provide lipid-derived feedstocks for conversion to liquid transportation fuels. Lipid extracts from microalgae are significantly more complex than those of traditional seed oils, and their composition changes significantly throughout the microalgal growth period. With three acyl side chains per molecule, triglycerides (TAGs) are an important fuel precursor, and the distribution of acyl chain composition for TAGs has a significant impact on fuel properties and processing. Therefore, determination of the distribution of microalgal TAG production is needed to assess the value of algal extracts designed for fuel production and to optimize strain, cultivation, andmore » harvesting practices. Methods utilized for TAG speciation commonly involve complicated and time-consuming chromatographic techniques. Here we present a method for TAG speciation and quantification based on direct-infusion mass spectrometry, which provides rapid characterization of TAG profiles without chromatographic separation. Specifically, we utilize Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) to provide a reference library of TAGs for the microalgae Nannochloropsis sp. that provides the basis for high-throughput TAG quantitation by time-of-flight mass spectrometry (TOF MS). In conclusion, we demonstrate the application of this novel approach for lipid characterization with respect to TAG compound distribution, which informs both immediate and future strain and process optimization strategies.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, Earl; Sudasinghe, Nilusha; Dandamudi, Kodanda Phani Raj

    Cultivation of microalgae has the potential to provide lipid-derived feedstocks for conversion to liquid transportation fuels. Lipid extracts from microalgae are significantly more complex than those of traditional seed oils, and their composition changes significantly throughout the microalgal growth period. With three acyl side chains per molecule, triglycerides (TAGs) are an important fuel precursor, and the distribution of acyl chain composition for TAGs has a significant impact on fuel properties and processing. Therefore, determination of the distribution of microalgal TAG production is needed to assess the value of algal extracts designed for fuel production and to optimize strain, cultivation, andmore » harvesting practices. Methods utilized for TAG speciation commonly involve complicated and time-consuming chromatographic techniques. Here we present a method for TAG speciation and quantification based on direct-infusion mass spectrometry, which provides rapid characterization of TAG profiles without chromatographic separation. Specifically, we utilize Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) to provide a reference library of TAGs for the microalgae Nannochloropsis sp. that provides the basis for high-throughput TAG quantitation by time-of-flight mass spectrometry (TOF MS). In conclusion, we demonstrate the application of this novel approach for lipid characterization with respect to TAG compound distribution, which informs both immediate and future strain and process optimization strategies.« less

  18. Multiple dual mode counter-current chromatography with variable duration of alternating phase elution steps.

    PubMed

    Kostanyan, Artak E; Erastov, Andrey A; Shishilov, Oleg N

    2014-06-20

    The multiple dual mode (MDM) counter-current chromatography separation processes consist of a succession of two isocratic counter-current steps and are characterized by the shuttle (forward and back) transport of the sample in chromatographic columns. In this paper, the improved MDM method based on variable duration of alternating phase elution steps has been developed and validated. The MDM separation processes with variable duration of phase elution steps are analyzed. Basing on the cell model, analytical solutions are developed for impulse and non-impulse sample loading at the beginning of the column. Using the analytical solutions, a calculation program is presented to facilitate the simulation of MDM with variable duration of phase elution steps, which can be used to select optimal process conditions for the separation of a given feed mixture. Two options of the MDM separation are analyzed: 1 - with one-step solute elution: the separation is conducted so, that the sample is transferred forward and back with upper and lower phases inside the column until the desired separation of the components is reached, and then each individual component elutes entirely within one step; 2 - with multi-step solute elution, when the fractions of individual components are collected in over several steps. It is demonstrated that proper selection of the duration of individual cycles (phase flow times) can greatly increase the separation efficiency of CCC columns. Experiments were carried out using model mixtures of compounds from the GUESSmix with solvent systems hexane/ethyl acetate/methanol/water. The experimental results are compared to the predictions of the theory. A good agreement between theory and experiment has been demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Preparation of trout liver microsomes for iron speciation in P-450 enzymes by AE-FPLC with ICP-(ORS)MS detection.

    PubMed

    Rodríguez-Cea, Andrés; de la Campa, María Rosario Fernández; Sanz-Medel, Alfredo

    2005-01-01

    Cytochromes P-450 are members of a superfamily of hemoproteins involved in the oxidative metabolism of various physiological and xenobiotic compounds in eukaryotes and prokaryotes. The multiplicity of this group of enzymes has been widely studied by chromatographic techniques, mainly high-performance liquid chromatography (HPLC). Because these enzymes are membrane-bound proteins, sample preparation for chromatographic separation of P-450 enzymes requires a solubilization step. The sample-preparation procedures are critical, because detergents affect not only the efficiency of protein solubilization but also their further chromatographic resolution. Trout liver microsomes have been taken here as a model sample to investigate iron speciation in cytochrome P-450. Trouts were treated intraperitoneally with beta-naphthoflavone, a potent inducer of some P-450 enzymes, and a microsomal suspension containing 7.4+/-0.1 nmol mL(-1) P-450 enzymes was obtained by ultracentrifugation. Lubrol PX was selected as detergent for solubilization, resulting in about 90% solubilization recovery. The solubilized cytochromes P-450 were further separated by AE-FPLC, with UV detection, or coupled to ICP-MS with an octapole reaction system, ICP-(ORS)MS (monitoring Fe signals at masses 54, 56, and 57). A sampling procedure and chromatographic conditions are developed and were successfully applied to iron speciation in trout liver P-450 enzymes. ICP-(ORS)MS detection of P-450 enzymes is Fe-specific and so will give accurate information on the prosthetic group of the protein, which can constitute an advantageous alternative to classical methods for detection of these hemoproteins.

  20. Separation and purification of γ-aminobutyric acid from fermentation broth by flocculation and chromatographic methodologies.

    PubMed

    Gao, Qiang; Duan, Qiang; Wang, Depei; Zhang, Yunze; Zheng, Chunyang

    2013-02-27

    To date, the multifunctional γ-aminobutyric acid (GABA) is mainly produced by microbial fermentation in industry. The purpose of this study was to find an effective method for separation and purification of 31.2 g/L initial GABA from the fermentation broth of Enterococcus raffinosus TCCC11660. To remove the impurities from fermentation broth, flocculation pretreatment using chitosan and sodium alginate was first implemented to facilitate subsequent filtration. Ultrafiltration followed two discontinuous diafiltration steps to effectively remove proteins and macromolecular pigments, and the resulting permeate was further decolored by DA201-CII resin at a high decoloration ratio and GABA recovery. Subsequently, ion exchange chromatography (IEC) with Amberlite 200C resin and gradient elution were applied for GABA separation from glutamate and arginine. Finally, GABA crystals of 99.1% purity were prepared via warm ethanol precipitation twice. Overall, our results reveal that the successive process including flocculation, filtration, ultrafiltration, decoloration, IEC, and crystallization is promising for scale-up GABA extraction from fermentation broth.

  1. High-performance liquid chromatographic enantioseparation of unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids on macrocyclic glycopeptide-based chiral stationary phases.

    PubMed

    Sipos, László; Ilisz, István; Nonn, Melinda; Fülöp, Ferenc; Pataj, Zoltán; Armstrong, Daniel W; Péter, Antal

    2012-04-06

    The enantiomers of four unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids were directly separated on chiral stationary phases containing macrocyclic glycopeptide antibiotics teicoplanin (Astec Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V) and vancomycin aglycone (Chirobiotic VAG) as chiral selectors. The effects of the mobile phase composition, the structure of the analytes and temperature on the separations were investigated. Experiments were performed at constant mobile phase compositions in the temperature range 5-45 °C to study the effects of temperature, and thermodynamic parameters were calculated from plots of lnk or lnα versus 1/T. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. It was found that the enantiomeric separations were in most cases enthalpy-driven. The sequence of elution of the enantiomers was determined in all cases. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. High-performance liquid chromatographic enantioseparation of monoterpene-based 2-amino carboxylic acids on macrocyclic glycopeptide-based phases.

    PubMed

    Sipos, László; Ilisz, István; Pataj, Zoltán; Szakonyi, Zsolt; Fülöp, Ferenc; Armstrong, Daniel W; Péter, Antal

    2010-10-29

    The enantiomers of five monoterpene-based 2-amino carboxylic acids were directly separated on chiral stationary phases containing macrocyclic glycopeptide antibiotics such as teicoplanin (Astec Chirobiotic T and T2) and teicoplanin aglycone (Chirobiotic TAG) as chiral selectors. The effects of pH, the mobile phase composition, the structure of the analyte and temperature on the separations were investigated. Experiments were performed at constant mobile phase compositions in the temperature range 10-40°C to study the effects of temperature and thermodynamic parameters on separations. Apparent thermodynamic parameters and T(iso) values were calculated from plots of ln k or ln α versus 1/T. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. It was found that the enantioseparations were in most cases enthalpy driven. The sequence of elution of the enantiomers was determined in all cases. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Separation of pharmacologically active nitrogen-containing compounds on silica gels modified with 6,10-ionene, dextran sulfate, and gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Ioutsi, A. N.; Shapovalova, E. N.; Ioutsi, V. A.; Mazhuga, A. G.; Shpigun, O. A.

    2017-12-01

    New stationary phases for HPLC are obtained via layer-by-layer deposition of polyelectrolytes and studied: (1) silica gel modified layer-by-layer with 6,10-ionene and dextran sulfate (Sorbent 1); (2) silica gel twice subjected to the above modification (Sorbent 2); and (3) silica gel modified with 6,10-ionene, gold nanoparticles, and dextran sulfate (Sorbent 3). The effect the content of the organic solvent in the mobile phase and the concentration and pH of the buffer solution have on the chromatographic behavior of several pharmacologically active nitrogen-containing compounds is studied. The sorbents are stable during the process and allow the effective separation of beta-blockers, calcium channel blockers, alpha-agonists, and antihistamines. A mixture of caffeine, nadolol, tetrahydrozoline, pindolol, orphenadrine, doxylamine, carbinoxamine, and chlorphenamine is separated in 6.5 min on the silica gel modified with 6,10-ionene, gold nanoparticles, and dextran sulfate.

  4. High-Throughput Analysis of Methylmalonic Acid in Serum, Plasma, and Urine by LC-MS/MS. Method for Analyzing Isomers Without Chromatographic Separation.

    PubMed

    Kushnir, Mark M; Nelson, Gordon J; Frank, Elizabeth L; Rockwood, Alan L

    2016-01-01

    Measurement of methylmalonic acid (MMA) plays an important role in the diagnosis of vitamin B12 deficiency. Vitamin B12 is an essential cofactor for the enzymatic carbon rearrangement of methylmalonyl-CoA (MMA-CoA) to succinyl-CoA (SA-CoA), and the lack of vitamin B12 leads to elevated concentrations of MMA. Presence of succinic acid (SA) complicates the analysis because mass spectra of MMA and SA are indistinguishable, when analyzed in negative ion mode and the peaks are difficult to resolve chromatographically. We developed a method for the selective analysis of MMA that exploits the significant difference in fragmentation patterns of di-butyl derivatives of the isomers MMA and SA in a tandem mass spectrometer when analyzed in positive ion mode. Tandem mass spectra of di-butyl derivatives of MMA and SA are very distinct; this allows selective analysis of MMA in the presence of SA. The instrumental analysis is performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive ion mode, which is, in combination with selective extraction of acidic compounds, is highly selective for organic acids with multiple carboxyl groups (dicarboxylic, tricarboxylic, etc.). In this method organic acids with a single carboxyl group are virtually undetectable in the mass spectrometer; the only organic acid, other than MMA, that is detected by this method is its isomer, SA. Quantitative measurement of MMA in this method is performed using a deconvolution algorithm, which mathematically resolves the signal corresponding to MMA and does not require chromatographic resolution of the MMA and SA peaks. Because of its high selectivity, the method utilizes isocratic chromatographic separation; reconditioning and re-equilibration of the chromatographic column between injections is unnecessary. The above features of the method allow high-throughput analysis of MMA with analysis cycle time of 1 min.

  5. The setup of an extraction system coupled to a hydrogen isotopes distillation column

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zamfirache, M.; Bornea, A.; Stefanescu, I.

    2008-07-15

    Among the most difficult problems of cryogenic distillation one stands apart: the extraction of the heavy fraction. By an optimal design of the cycle scheme, this problem could be avoided. A 'worst case scenario' is usually occurring when the extracted fraction consists of one prevalent isotope such as hydrogen and small amounts of the other two hydrogen isotopes (deuterium and/or tritium). This situation is further complicated by two parameters of the distillation column: the extraction flow rate and the hold-up. The present work proposes the conceptual design of an extraction system associated to the cryogenic distillation column used in hydrogenmore » separation processes. During this process, the heavy fraction (DT, T{sub 2}) is separated, its concentration being the highest at the bottom of the distillation column. From this place the extraction of the gaseous phase can now begin. Being filled with adsorbent, the extraction system is used to temporarily store the heavy fraction. Also the extraction system provides samples for the gas Chromatograph. The research work is focused on the existent pilot plant for tritium and deuterium separation from our institute to validate the experiments carried out until now. (authors)« less

  6. [Influences of the mobile phase constitution, salt concentration and pH value on retention characters of proteins on the metal chelate column].

    PubMed

    Li, R; Di, Z M; Chen, G L

    2001-09-01

    The effects of the nature and concentration of salts, pH value and competitive eluent in the mobile phase on the protein retention have been systematically investigated. A mathematical expression describing the protein retention in metal chelate chromatography has been derived. It is proposed that the eluting power of the salt solution can be expressed by the eluent strength exponent epsilon. According to the retention characters of protein under different chromatographic conditions, the interaction between the various metal chelate ligands and proteins is discussed. The protein retention on the metal chelate column is a cooperative interactions of coordination, electrostatic and hydrophobic interaction. For the strong combined metal column with proteins such as IDA-Cu, the coordination is the most important, and the electrostatic interaction is secondary in chromatographic process. However, for the weak combined metal columns with proteins such as IDA-Ni, IDA-Co and IDA-Zn, the electrostatic interaction between the metal chelate ligands and proteins is the chief one, while the coordination is the next in importance. When the mobile phase contains high concentration of salt which can't form complex with the immobilized metal, the hydrophobic interaction between the protein and stationary phase will be increased. As the interaction between the metal chelate ligand and proteins relates to chromatographic operating conditions closely, different elution processes may be selected for different metal chelate columns. The gradient elution is generally performed by the low concentration of salt or different pH for weakly combined columns with proteins, however the competitive elution procedure is commonly utilized for strongly combined column. The experiment showed that NH3 is an excellent competitive eluent. It isn't only give the efficient separation of proteins, but also has the advantages of cheapness, less bleeding of the immobilized metals and ease of controlling NH3 concentration. The interaction between the metal chelate ligand and proteins and the selectivity of metal chelate chromatography can be changed through changing chromatographic conditions.

  7. A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas

    PubMed Central

    Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J.; Lang, Walter

    2017-01-01

    Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system. PMID:28991173

  8. Chromatographic and mass spectral methods of identification for the side-chain and ring regioisomers of methylenedioxymethamphetamine.

    PubMed

    Aalberg, L; DeRuiter, J; Noggle, F T; Sippola, E; Clark, C R

    2000-08-01

    The popular drug of abuse 3,4-methylenedioxymethamphetamine (MDMA) is one of a total of 10 regioisomeric 2,3- and 3,4-methylenedioxyphenethylamines of MW 193 that yields regioisomeric fragment ions with equivalent mass (m/z 58 and 135/136) in the electron-impact (EI) mass spectrum. Thus, these 10 methylenedioxyphenethylamines are uniquely isomeric; they have the same molecular weight and equivalent major fragments in their mass spectra. The specific identification of one of these compounds (i.e., Ecstasy or 3,4-MDMA) in a forensic drug sample depends upon the analyst's ability to eliminate the other regioisomers as possible interfering or coeluting substances. This study reports the synthesis, chemical properties, spectral characterization, and chromatographic analysis of these 10 unique regioisomers. The ten 2,3- and 3,4-regioisomers of MDMA are synthesized from commercially available precursor chemicals. In the EI mass spectra, the side-chain regioisomers show some variation in the relative intensity of the major ions, with the exception of only one or two minor ions that might be considered side-chain specific fragments. The position of substitution for the methylenedioxy ring is not easily determined by mass spectral techniques, and the ultimate identification of any one of these amines with the elimination of the other nine must depend heavily upon chromatographic methods. The chromatographic separation of these 10 uniquely regioisomeric amines are studied using reversed-phase liquid chromatographic methods with gradient elution and gas chromatographic techniques with temperature program optimization.

  9. Method and apparatus for continuous annular electrochromatography

    DOEpatents

    Scott, Charles D.

    1987-01-01

    Separation of complex mixtures and solutions can be carried out using a method and apparatus for continuous annular electrochromatography. Solutes are diverted radially by an imposed electrical field as they move downward in a rotating chromatographic column.

  10. Thin-Layer and Paper Chromatography.

    ERIC Educational Resources Information Center

    Sherma, Joseph; Fried, Bernard

    1984-01-01

    Reviews literature on chromatography examining: books, reviews, student experiments; chromatographic systems, techniques, apparatus; detecting and identification of separated zones; preparative chromatography and radiochromatography; and applications related to specific materials (such as acids, alcohols, amino acids, antibiotics, enzymes, dyes,…

  11. Preparation and characterization of six calixarene bonded stationary phases for high performance liquid chromatography.

    PubMed

    Ding, Chenghua; Qu, Kang; Li, Yongbo; Hu, Kai; Liu, Hongxia; Ye, Baoxian; Wu, Yangjie; Zhang, Shusheng

    2007-11-02

    Six calixarene bonded silica gel stationary phases were prepared and characterized by elemental analysis, infrared spectroscopy and thermal analysis. Their chromatographic performance was investigated by using PAHs, aromatic positional isomers and E- and Z-ethyl 3-(4-acetylphenyl) acrylate isomers as probes. Separation mechanism based on the different interactions between calixarenes and analytes were discussed. The chromatographic behaviors of those analytes on the calixarene columns were influenced by the supramolecular interaction including pi-pi interaction, space steric hindrance and hydrogen bonding interaction between calixarenes and analytes. Notably, the presence of polar groups (-OH, -NO(2) and -NH(2)) in the aromatic isomers could improve their separation selectivity on calixarene phase columns. The results from quantum chemistry calculation using DFT-B3LYP/STO-3G* base group were consistent with the retention behaviors of PHAs on calix[4]arene column.

  12. High-performance liquid chromatographic determination of loxoprofen and its diastereomeric alcohol metabolites in biological fluids by fluorescence labelling with 4-bromomethyl-6,7-methylenedioxycoumarin.

    PubMed

    Naganuma, H; Kawahara, Y

    1990-09-14

    A simple and sensitive high-performance liquid chromatographic procedure to determine loxoprofen and its diastereomeric alcohol metabolites in biological specimens is described. The analysis involves liquid-liquid extraction with benzene, pre-column derivatization with a highly fluorogenic reagent, 4-bromomethyl-6,7-methylenedioxycoumarin (BrMDC) and subsequent separation on a reversed-phase column. Loxoprofen, its pharmacologically active metabolite, trans-alcohol, and less active cis-alcohol were completely separated within 20 min with a mobile phase of 55% of aqueous acetonitrile containing acetic acid. Any endogenous substances do not interfere in the analysis of either plasma or urine samples. The quantitation limit was 0.01 micrograms/ml for human plasma and 0.05 micrograms/ml for urine. The method was applied to a pharmacokinetic study in healthy human subjects who had received 60 mg of loxoprofen sodium.

  13. Synthesis of cellulose-2,3-bis(3,5-dimethylphenylcarbamate) in an ionic liquid and its chiral separation efficiency as stationary phase.

    PubMed

    Liu, Runqiang; Zhang, Yijun; Bai, Lianyang; Huang, Mingxian; Chen, Jun; Zhang, Yuping

    2014-04-11

    A chiral selector of cellulose-2,3-bis(3,5-dimethylphenylcarbamate) (CBDMPC) was synthesized by reacting 3,5-dimethylphenyl isocyanate with microcrystalline cellulose dissolved in an ionic liquid of 1-allyl-3-methyl-imidazolium chloride (AMIMCl). The obtained chiral selector was effectively characterized by infrared spectroscopy, elemental analysis and 1H NMR. The selector was reacted with 3-aminopropylsilanized silica gel and the CBDMPC bonded chiral stationary phase (CSP) was obtained. Chromatographic evaluation of the prepared CSPs was conducted by high performance liquid chromatographic (HPLC) and baseline separation of three typical fungicides including hexaconazole, metalaxyl and myclobutanil was achieved using n-hexane/isopropanol as the mobile phase with a flow rate 1.0 mL/min. Experimental results also showed that AMIMCl could be recycled easily and reused in the preparation of CSPs as an effective reaction media.

  14. Synthesis of Cellulose-2,3-bis(3,5-dimethylphenylcarbamate) in an Ionic Liquid and Its Chiral Separation Efficiency as Stationary Phase

    PubMed Central

    Liu, Runqiang; Zhang, Yijun; Bai, Lianyang; Huang, Mingxian; Chen, Jun; Zhang, Yuping

    2014-01-01

    A chiral selector of cellulose-2,3-bis(3,5-dimethylphenylcarbamate) (CBDMPC) was synthesized by reacting 3,5-dimethylphenyl isocyanate with microcrystalline cellulose dissolved in an ionic liquid of 1-allyl-3-methyl-imidazolium chloride (AMIMCl). The obtained chiral selector was effectively characterized by infrared spectroscopy, elemental analysis and 1H NMR. The selector was reacted with 3-aminopropylsilanized silica gel and the CBDMPC bonded chiral stationary phase (CSP) was obtained. Chromatographic evaluation of the prepared CSPs was conducted by high performance liquid chromatographic (HPLC) and baseline separation of three typical fungicides including hexaconazole, metalaxyl and myclobutanil was achieved using n-hexane/isopropanol as the mobile phase with a flow rate 1.0 mL/min. Experimental results also showed that AMIMCl could be recycled easily and reused in the preparation of CSPs as an effective reaction media. PMID:24733066

  15. Blending protein separation and peptide analysis through real-time proteolytic digestion.

    PubMed

    Slysz, Gordon W; Schriemer, David C

    2005-03-15

    Typical liquid- or gel-based protein separations require enzymatic digestion as an important first step in generating protein identifications. Traditional protocols involve long-term proteolytic digestion of the separated protein, often leading to sample loss and reduced sensitivity. Previously, we presented a rapid method of proteolytic digestion that showed excellent digestion of resistant and low concentrations of protein without requiring reduction and alkylation. Here, we demonstrate on-line, real-time tryptic digestion in conjunction with reversed-phase protein separation. The studies were aimed at optimizing pH and ionic strength and the size of the digestion element, to produce maximal protein digestion with minimal effects on chromatographic integrity. Upon establishing optimal conditions, the digestion element was attached downstream from a capillary C4 reversed-phase column. A four-protein mixture was processed through the combined system, and the resulting peptides were analyzed on-line by electrospray mass spectrometry. Extracted ion chromatograms for protein chromatography based on peptide elution were generated. These were shown to emulate ion chromatograms produced in a subsequent run without the digestion element, based on protein elution. The methodology will enable rapid and sensitive analysis of liquid-based protein separations using the power of bottom-up proteomics methodologies.

  16. Preparation and evaluation of diblock copolymer-grafted silica by sequential surface initiated-atom transfer radical polymerization for reverse-phase/ion-exchange mixed-mode chromatography.

    PubMed

    Bo, Chun Miao; Wang, Chaozhan; Wei, Yin Mao

    2017-12-01

    A novel approach that involved the grafting of diblock copolymer with two types of monomer onto substrate by sequential surface initiated-atom transfer radical polymerization was proposed to prepare a mixed-mode chromatographic stationary phase. The distinguishing feature of this method is that it can be applied in the preparation of various mixed-mode stationary phases. In this study, a new reverse-phase/ion-exchange stationary phase was prepared by grafting hydrophobic styrene and cationic sodium 4-styrenesulfonate by the proposed approach onto silica surface. The chromatographic properties of the prepared stationary phase were evaluated by the separation of benzene derivatives, anilines, and β-agonists, and by the effect of pH values and acetonitrile content on the retention. Compared with typical RP columns, the prepared stationary phase achieved the better resolution and higher selectivity at a shorter separation time and lower organic content. Moreover, the application of the prepared column was proved by separating widely distributed polar and charged compounds simultaneously. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Chromatographic separation and detection of contaminants from whole milk powder using a chitosan-modified silver nanoparticles surface-enhanced Raman scattering device.

    PubMed

    Li, Dan; Lv, Di Y; Zhu, Qing X; Li, Hao; Chen, Hui; Wu, Mian M; Chai, Yi F; Lu, Feng

    2017-06-01

    Methods for the on-site analysis of food contaminants are in high demand. Although portable Raman spectroscopy is commonly used to test food on-site, it can be challenge to achieve this goal with rapid detection and inexpensive substrate. In this study, we detected trace food contaminants in samples of whole milk powder using the methods that combined chromatography with surface-enhanced Raman scattering detection (SERS). We developed a simple and efficient technique to fabricate the paper with chitosan-modified silver nanoparticles as a SERS-active substrate. The soaking time of paper and the concentration of chitosan solution were optimized for chromatographic separation and SERS detection. We then studied the separation properties for real applications including complex sample matrices, and detected melamine at 1mg/L, dicyandiamide at 100mg/L and sodium sulfocyanate at 10mg/L in whole milk powder. As such, our methods have great potential for field-based detection of milk contaminants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Green approach using monolithic column for simultaneous determination of coformulated drugs.

    PubMed

    Yehia, Ali M; Mohamed, Heba M

    2016-06-01

    Green chemistry and sustainability is now entirely encompassed across the majority of pharmaceutical companies and research labs. Researchers' attention is careworn toward implementing the green analytical chemistry principles for more eco-friendly analytical methodologies. Solvents play a dominant role in determining the greenness of the analytical procedure. Using safer solvents, the greenness profile of the methodology could be increased remarkably. In this context, a green chromatographic method has been developed and validated for the simultaneous determination of phenylephrine, paracetamol, and guaifenesin in their ternary pharmaceutical mixture. The chromatographic separation was carried out using monolithic column and green solvents as mobile phase. The use of monolithic column allows efficient separation protocols at higher flow rates, which results in short time of analysis. Two-factor three-level experimental design was used to optimize the chromatographic conditions. The greenness profile of the proposed methodology was assessed using eco-scale as a green metrics and was found to be an excellent green method with regard to the usage and production of hazardous chemicals and solvents, energy consumption, and amount of produced waste. The proposed method improved the environmental impact without compromising the analytical performance criteria and could be used as a safer alternate for the routine analysis of the studied drugs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    PubMed Central

    Al-Degs, Yahya; Andri, Bertyl; Thiébaut, Didier; Vial, Jérôme

    2017-01-01

    Retention mechanisms involved in supercritical fluid chromatography (SFC) are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase), a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC) was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition). Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition) data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns' function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components. PMID:28695040

  20. Evaluation of different derivatisation approaches for gas chromatographic-mass spectrometric analysis of carbohydrates in complex matrices of biological and synthetic origin.

    PubMed

    Becker, M; Zweckmair, T; Forneck, A; Rosenau, T; Potthast, A; Liebner, F

    2013-03-15

    Gas chromatographic analysis of complex carbohydrate mixtures requires highly effective and reliable derivatisation strategies for successful separation, identification, and quantitation of all constituents. Different single-step (per-trimethylsilylation, isopropylidenation) and two-step approaches (ethoximation-trimethylsilylation, ethoximation-trifluoroacetylation, benzoximation-trimethylsilylation, benzoximation-trifluoroacetylation) have been comprehensively studied with regard to chromatographic characteristics, informational value of mass spectra, ease of peak assignment, robustness toward matrix effects, and quantitation using a set of reference compounds that comprise eight monosaccharides (C(5)-C(6)), glycolaldehyde, and dihydroxyacetone. It has been shown that isopropylidenation and the two oximation-trifluoroacetylation approaches are least suitable for complex carbohydrate matrices. Whereas the former is limited to compounds that contain vicinal dihydroxy moieties in cis configuration, the latter two methods are sensitive to traces of trifluoroacetic acid which strongly supports decomposition of ketohexoses. It has been demonstrated for two "real" carbohydrate-rich matrices of biological and synthetic origin, respectively, that two-step ethoximation-trimethylsilylation is superior to other approaches due to the low number of peaks obtained per carbohydrate, good peak separation performance, structural information of mass spectra, low limits of detection and quantitation, minor relative standard deviations, and low sensitivity toward matrix effects. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Two multidimensional chromatographic methods for enantiomeric analysis of o,p'-DDT and o,p'-DDD in contaminated soil and air in a malaria area of South Africa.

    PubMed

    Naudé, Yvette; Rohwer, Egmont R

    2012-06-12

    In rural parts of South Africa the organochlorine insecticide DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane) is still used for malaria vector control where traditional dwellings are sprayed on the inside with small quantities of technical DDT. Since o,p'-DDT may show enantioselective oestrogenicity and biodegradability, it is important to analyse enantiomers of o,p'-DDT and its chiral degradation product, o,p'-DDD, for both health and environmental-forensic considerations. Generally, chiral analysis is performed using heart-cut multidimensional gas chromatography (MDGC) and, more recently, comprehensive two-dimensional gas chromatography (GC×GC). We developed an off-line gas chromatographic fraction collection (heart-cut) procedure for the selective capturing of the appropriate isomers from a first apolar column, followed by reinjection and separation on a second chiral column. Only the o,p'-isomers of DDT and DDD fractions from the first dimension complex chromatogram (achiral apolar GC column separation) were selectively collected onto a polydimethylsiloxane (PDMS) multichannel open tubular silicone rubber trap by simply placing the latter device on the flame tip of an inactivated flame ionisation detector (FID). The multichannel trap containing the o,p'-heart-cuts was then thermally desorbed into a GC with time-of-flight mass spectrometry detection (GC-TOFMS) for second dimension enantioselective separation on a chiral column (β-cyclodextrin-based). By selectively capturing only the o,p'-isomers from the complex sample chromatogram, (1)D separation of ultra-trace level enantiomers could be achieved on the second chiral column without matrix interference. Here, we present solventless concentration techniques for extraction of DDT from contaminated soil and air, and report enantiomeric fraction (EF) values of o,p'-DDT and o,p'-DDD obtained by a new multidimensional approach for heart-cut gas chromatographic fraction collection for off-line second dimension enantiomeric separation by (1)D GC-TOFMS of selected isomers. This multidimensional method is compared to the complementary technique of comprehensive GC×GC-TOFMS using the same enantioselective column, this time as the first dimension of separation. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Determination of hydroxytyrosol and tyrosol by liquid chromatography for the quality control of cosmetic products based on olive extracts.

    PubMed

    Miralles, Pablo; Chisvert, Alberto; Salvador, Amparo

    2015-01-01

    An analytical method for the simultaneous determination of hydroxytyrosol and tyrosol in different types of olive extract raw materials and cosmetic cream samples has been developed. The determination was performed by liquid chromatography with UV spectrophotometric detection. Different chromatographic parameters, such as mobile phase pH and composition, oven temperature and different sample preparation variables were studied. The best chromatographic separation was obtained under the following conditions: C18 column set at 35°C and isocratic elution of a mixture ethanol: 1% acetic acid solution at pH 5 (5:95, v/v) as mobile phase pumped at 1 mL min(-1). The detection wavelength was set at 280 nm and the total run time required for the chromatographic analysis was 10 min, except for cosmetic cream samples where 20 min runtime was required (including a cleaning step). The method was satisfactorily applied to 23 samples including solid, water-soluble and fat-soluble olive extracts and cosmetic cream samples containing hydroxytyrosol and tyrosol. Good recoveries (95-107%) and repeatability (1.1-3.6%) were obtained, besides of limits of detection values below the μg mL(-1) level. These good analytical features, as well as its environmentally-friendly characteristics, make the presented method suitable to carry out both the control of the whole manufacture process of raw materials containing the target analytes and the quality control of the finished cosmetic products. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Trace Gas Analyzer (TGA) program

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

  4. Research on miniature gas analysis systems

    NASA Technical Reports Server (NTRS)

    Angell, J. B.

    1974-01-01

    Technology for fabricating very small valves, whose function will be to introduce a small sample of the gas to be analyzed into the main carrier gas stream flowing through the chromatograph column is described. In addition, some analyses were made of the factors governing the resolution of gas chromatographs, particularly those with miniature columns. These analyses show how important the column lining thickness is in governing the ability of a miniature column to separate components of an unknown gas. A brief description of column lining factors is included. Preliminary work on a super small thermistor detector is included.

  5. Methods and apparatus for analysis of chromatographic migration patterns

    DOEpatents

    Stockham, Thomas G.; Ives, Jeffrey T.

    1993-01-01

    A method and apparatus for sharpening signal peaks in a signal representing the distribution of biological or chemical components of a mixture separated by a chromatographic technique such as, but not limited to, electrophoresis. A key step in the method is the use of a blind deconvolution technique, presently embodied as homomorphic filtering, to reduce the contribution of a blurring function to the signal encoding the peaks of the distribution. The invention further includes steps and apparatus directed to determination of a nucleotide sequence from a set of four such signals representing DNA sequence data derived by electrophoretic means.

  6. Chromatographic resolution of closely related species in pharmaceutical chemistry: dehalogenation impurities and mixtures of halogen isomers.

    PubMed

    Regalado, Erik L; Zhuang, Ping; Chen, Yadan; Makarov, Alexey A; Schafer, Wes A; McGachy, Neil; Welch, Christopher J

    2014-01-07

    In recent years, the use of halogen-containing molecules has proliferated in the pharmaceutical industry, where the incorporation of halogens, especially fluorine, has become vitally important for blocking metabolism and enhancing the biological activity of pharmaceuticals. The chromatographic separation of halogen-containing pharmaceuticals from associated isomers or dehalogenation impurities can sometimes be quite difficult. In an attempt to identify the best current tools available for addressing this important problem, a survey of the suitability of four chromatographic method development platforms (ultra high-performance liquid chromatography (UHPLC), core shell HPLC, achiral supercritical fluid chromatography (SFC) and chiral SFC) for separating closely related mixtures of halogen-containing pharmaceuticals and their dehalogenated isosteres is described. Of the 132 column and mobile phase combinations examined for each mixture, a small subset of conditions were found to afford the best overall performance, with a single UHPLC method (2.1 × 50 mm, 1.9 μm Hypersil Gold PFP, acetonitrile/methanol based aqueous eluents containing either phosphoric or perchloric acid with 150 mM sodium perchlorate) affording excellent separation for all samples. Similarly, a survey of several families of closely related halogen-containing small molecules representing the diversity of impurities that can sometimes be found in purchased starting materials for synthesis revealed chiral SFC (Chiralcel OJ-3 and Chiralpak IB, isopropanol or ethanol with 25 mM isobutylamine/carbon dioxide) as well as the UHPLC (2.1 × 50 mm, 1.8 μm ZORBAX RRHD Eclipse Plus C18 and the Gold PFP, acetonitrile/methanol based aqueous eluents containing phosphoric acid) as preferred methods.

  7. Glyphosate analysis using sensors and electromigration separation techniques as alternatives to gas or liquid chromatography.

    PubMed

    Gauglitz, Günter; Wimmer, Benedikt; Melzer, Tanja; Huhn, Carolin

    2018-01-01

    Since its introduction in 1974, the herbicide glyphosate has experienced a tremendous increase in use, with about one million tons used annually today. This review focuses on sensors and electromigration separation techniques as alternatives to chromatographic methods for the analysis of glyphosate and its metabolite aminomethyl phosphonic acid. Even with the large number of studies published, glyphosate analysis remains challenging. With its polar and depending on pH even ionic functional groups lacking a chromophore, it is difficult to analyze with chromatographic techniques. Its analysis is mostly achieved after derivatization. Its purification from food and environmental samples inevitably results incoextraction of ionic matrix components, with a further impact on analysis derivatization. Its purification from food and environmental samples inevitably results in coextraction of ionic matrix components, with a further impact on analysis and also derivatization reactions. Its ability to form chelates with metal cations is another obstacle for precise quantification. Lastly, the low limits of detection required by legislation have to be met. These challenges preclude glyphosate from being analyzed together with many other pesticides in common multiresidue (chromatographic) methods. For better monitoring of glyphosate in environmental and food samples, further fast and robust methods are required. In this review, analytical methods are summarized and discussed from the perspective of biosensors and various formats of electromigration separation techniques, including modes such as capillary electrophoresis and micellar electrokinetic chromatography, combined with various detection techniques. These methods are critically discussed with regard to matrix tolerance, limits of detection reached, and selectivity.

  8. Importance of MS selectivity and chromatographic separation in LC-MS/MS-based methods when investigating pharmaceutical metabolites in water. Dipyrone as a case of study.

    PubMed

    Ibáñez, M; Gracia-Lor, E; Sancho, J V; Hernández, F

    2012-08-01

    Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking-water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high-resolution MS data using a hybrid quadrupole time-of-flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co-eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC-MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected. Copyright © 2012 John Wiley & Sons, Ltd.

  9. A unified classification of stationary phases for packed column supercritical fluid chromatography.

    PubMed

    West, C; Lesellier, E

    2008-05-16

    The use of supercritical fluids as chromatographic mobile phases allows to obtain rapid separations with high efficiency on packed columns, which could favour the replacement of numerous HPLC methods by supercritical fluid chromatography (SFC) ones. Moreover, despite some unexpected chromatographic behaviours, general retention rules are now well understood, and mainly depend on the nature of the stationary phase. The use of polar stationary phases improves the retention of polar compounds, when C18-bonded silica favours the retention of hydrocarbonaceous compounds. In this sense, reversed-phase and normal-phase chromatography can be achieved in SFC, as in HPLC. However, these two domains are clearly separated in HPLC due to the opposite polarity of the mobile phases used for each method. In SFC, the same mobile phase can be used with both polar and non-polar stationary phases. Consequently, the need for a novel classification of stationary phases in SFC appears, allowing a unification of the classical reversed- and normal-phase domains. In this objective, the paper presents the development of a five-dimensional classification based on retention data for 94-111 solutes, using 28 commercially available columns representative of three major types of stationary phases. This classification diagram is based on a linear solvation energy relationship, on the use of solvation vectors and the calculation of similarity factors between the different chromatographic systems. This classification will be of great help in the choice of the well-suited stationary phase, either in regards of a particular separation or to improve the coupling of columns with complementary properties.

  10. Identification of trace levels of selenomethionine and related organic selenium species in high-ionic-strength waters.

    PubMed

    LeBlanc, Kelly L; Ruzicka, Josef; Wallschläger, Dirk

    2016-02-01

    A new anion-exchange chromatographic separation method was used for the simultaneous speciation analysis of selenoamino acids and the more ubiquitous inorganic selenium oxyanions, selenite and selenate. For quantification, this separation was coupled to inductively coupled plasma-mass spectrometry to achieve an instrumental detection limit of 5 ng Se L(-1) for all species. This chromatographic method was also coupled to electrospray tandem mass spectrometry to observe the negative ion mode fragmentation of selenomethionine and one of its oxidation products. Low detection limits were achieved, which were similar to those obtained using inductively coupled plasma-mass spectrometry. An extensive preconcentration and cleanup procedure using cation-exchange solid-phase extraction was developed for the identification and quantification of trace levels of selenomethionine in environmental samples. Preconcentration factors of up to five were observed for selenomethionine, which in addition to the removal of high concentrations of sulphate and chloride from industrial process waters, allowed for an unambiguous analysis that would have been impossible otherwise. Following these methods, selenomethionine was identified at an original concentration of 3.2 ng Se L(-1) in samples of effluent collected at a coal-fired power plant's biological remediation site. It is the first time that this species has been identified in the environment, outside of a biological entity. Additionally, oxidation products of selenomethionine were identified in river water and laboratory algal culture samples. High-resolution mass spectrometry was employed to postulate the chemical structures of these species.

  11. pH-dependence of single-protein adsorption and diffusion at a liquid chromatographic interface.

    PubMed

    Kisley, Lydia; Poongavanam, Mohan-Vivekanandan; Kourentzi, Katerina; Willson, Richard C; Landes, Christy F

    2016-02-01

    pH is a common mobile phase variable used to control protein separations due to the tunable nature of amino acid and adsorbent charge. Like other column variables such as column density and ligand loading density, pH is usually optimized empirically. Single-molecule spectroscopy extracts molecular-scale data to provide a framework for mechanistic optimization of pH. The adsorption and diffusion of a model globular protein, α-lactalbumin, was studied by single-molecule microscopy at a silica-aqueous interface analogous to aqueous normal phase and hydrophilic interaction chromatography and capillary electrophoresis interfaces at varied pH. Electrostatic repulsion resulting in free diffusion was observed at pH above the isoelectric point of the protein. In contrast, at low pH strong adsorption and surface diffusion with either no (D ∼ 0.01 μm(2) /s) or translational (D ∼ 0.3 μm(2) /s) motion was observed where the protein likely interacted with the surface through electrostatic, hydrophobic, and hydrogen bonding forces. The fraction of proteins immobilized could be increased by lowering the pH. These results show that retention of proteins at the silica interface cannot be viewed solely as an adsorption/desorption process and that the type of surface diffusion, which ultimately leads to ensemble chromatographic separations, can be controlled by tuning long-range electrostatic and short-range hydrophobic and hydrogen bonding forces with pH. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Chromatographic Separation and Visual Detection on Wicking Microfluidic Devices: Quantitation of Cu2+ in Surface, Ground, and Drinking Water.

    PubMed

    Bandara, Gayan C; Heist, Christopher A; Remcho, Vincent T

    2018-02-20

    Copper is widely applied in industrial and technological applications and is an essential micronutrient for humans and animals. However, exposure to high environmental levels of copper, especially through drinking water, can lead to copper toxicity, resulting in severe acute and chronic health effects. Therefore, regular monitoring of aqueous copper ions has become necessary as recent anthropogenic activities have led to elevated environmental concentrations of copper. On-site monitoring processes require an inexpensive, simple, and portable analytical approach capable of generating reliable qualitative and quantitative data efficiently. Membrane-based lateral flow microfluidic devices are ideal candidates as they facilitate rapid, inexpensive, and portable measurements. Here we present a simple, chromatographic separation approach in combination with a visual detection method for Cu 2+ quantitation, performed in a lateral flow microfluidic channel. This method appreciably minimizes interferences by incorporating a nonspecific polymer inclusion membrane (PIM) based assay with a "dot-counting" approach to quantification. In this study, hydrophobic polycaprolactone (PCL)-filled glass microfiber (GMF) membranes were used as the base substrate onto which the PIM was evenly dispensed as an array of dots. The devices thus prepared were then selectively exposed to oxygen radicals through a mask to generate a hydrophilic surface path along which the sample was wicked. Using this approach, copper concentrations from 1 to 20 ppm were quantified from 5 μL samples using only visual observation of the assay device.

  13. HPLC Characterization of Phenol-Formaldehyde Resole Resin Used in Fabrication of Shuttle Booster Nozzles

    NASA Technical Reports Server (NTRS)

    Young, Philip R.

    1999-01-01

    A reverse phase High Performance Liquid Chromatographic method was developed to rapidly fingerprint a phenol-formaldehyde resole resin similar to Durite(R) SC-1008. This resin is used in the fabrication of carbon-carbon composite materials from which Space Shuttle Solid Rocket Booster nozzles are manufactured. A knowledge of resin chemistry is essential to successful composite processing and performance. The results indicate that a high quality separation of over 35 peaks in 25 minutes were obtained using a 15 cm Phenomenex LUNA C8 bonded reverse phase column, a three-way water-acetonitrile-methanol nonlinear gradient, and LTV detection at 280 nm.

  14. Efficient fabrication of high-capacity immobilized metal ion affinity chromatographic media: The role of the dextran-grafting process and its manipulation.

    PubMed

    Zhao, Lan; Zhang, Jingfei; Huang, Yongdong; Li, Qiang; Zhang, Rongyue; Zhu, Kai; Suo, Jia; Su, Zhiguo; Zhang, Zhigang; Ma, Guanghui

    2016-03-01

    Novel high-capacity Ni(2+) immobilized metal ion affinity chromatographic media were prepared through the dextran-grafting process. Dextran was grafted to an allyl-activated agarose-based matrix followed by functionalization for the immobilized metal ion affinity chromatographic media. With elaborate regulation of the allylation degree, dextran was completely or partly grafted to agarose microspheres, namely, completely dextran-grafted agarose microspheres and partly dextran-grafted ones, respectively. Confocal laser scanning microscope results demonstrated that a good adjustment of dextran-grafting degree was achieved, and dextran was distributed uniformly in whole completely dextran-grafted microspheres, while just distributed around the outside of the partly dextran-grafted ones. Flow hydrodynamic properties were improved greatly after the dextran-grafting process, and the flow velocity increased by about 30% compared with that of a commercial chromatographic medium (Ni Sepharose FF). A significant improvement of protein binding performance was also achieved by the dextran-grafting process, and partly dextran-grafted Ni(2+) chelating medium had a maximum binding capacity for His-tagged lactate dehydrogenase about 2.5 times higher than that of Ni Sepharose FF. The results indicated that this novel chromatographic medium is promising for applications in high-efficiency and large-scale protein purification. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Liquid Chromatographic Determination of Nitroanilines: An Experiment for the Quantitative Analysis Laboratory.

    ERIC Educational Resources Information Center

    Cantwell, Frederick F.; Brown, David W.

    1981-01-01

    Describes a three-hour liquid chromatography experiment involving rapid separation of colored compounds in glass columns packed with a nonpolar absorbent. Includes apparatus design, sample preparation, experimental procedures, and advantages for this determination. (SK)

  16. Analysis and design of a capsule landing system and surface vehicle control system for Mars exploration

    NASA Technical Reports Server (NTRS)

    Frederick, D. K.; Lashmet, P. K.; Moyer, W. R.; Sandor, G. N.; Shen, C. N.; Smith, E. J.; Yerazunis, S. W.

    1973-01-01

    The following tasks related to the design, construction, and evaluation of a mobile planetary vehicle for unmanned exploration of Mars are discussed: (1) design and construction of a 0.5 scale dynamic vehicle; (2) mathematical modeling of vehicle dynamics; (3) experimental 0.4 scale vehicle dynamics measurements and interpretation; (4) vehicle electro-mechanical control systems; (5) remote control systems; (6) collapsibility and deployment concepts and hardware; (7) design, construction and evaluation of a wheel with increased lateral stiffness, (8) system design optimization; (9) design of an on-board computer; (10) design and construction of a laser range finder; (11) measurement of reflectivity of terrain surfaces; (12) obstacle perception by edge detection; (13) terrain modeling based on gradients; (14) laser scan systems; (15) path selection system simulation and evaluation; (16) gas chromatograph system concepts; (17) experimental chromatograph separation measurements and chromatograph model improvement and evaluation.

  17. Gas chromatographic determination of carboxylic acid chlorides and residual carboxylic acid precursors used in the production of some penicillins.

    PubMed

    Lauback, R G; Balitz, D F; Mays, D L

    1976-05-01

    An improved gas chromatographic method is described for the simultaneous determination of carboxylic acid chlorides and related carboxylic acids used in the production of some commercial semisynthetic penicillins. The acid chloride reacts with diethylamine to form the corresponding diethylamide. Carboxylic acid impurities are converted to trimethylsilyl esters. The two derivatives are separated and quantitated in the same chromatographic run. This method, an extension of the earlier procedure of Hishta and Bomstein (1), has been applied to the acid chlorides used to make oxacillin, cloxacillin, dicloxacillin, and methicillin (Figure 1); it shows promise of application to other acid chlorides. The determination is more selective than the usual titration methods, which do not differentiate among acids with similar pK's. Relative standard deviations of the acid chloride determination are 1.0-2.5%. Residual carboxylic acid can be repetitively determined within a range of 0.6% absolute.

  18. Separation of alkylphenols by normal-phase and reversed-phase high-performance liquid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schabron, J.F.; Hurtubise, R.J.; Silver, H.F.

    1978-11-01

    Empirical correlation factors were developed which relate log k' values for alkylphenols, the naphthols, and two phenylphenols to structural features. Both normal-phase and reversed-phase chromatographic systems were studied. The stationary phases employed in the normal-phase work were ..mu..-Bondapak CN, ..mu..-Bondapak NH/sub 2/, and ..mu..-Porasil. The structural features which affect retention in the normal-phase chromatographic systems are the number of ortho substituents, the number of aliphatic carbons, and the number of aromatic rings. The stationary phases employed in the reversed-phase work were ..mu..-Bondapak C/sub 18/ and ..mu..-Bondapak CN. The structural features which affect retention in the reversed-phase chromatographic systems are themore » number of aliphatic carbons and the number of aromatic double bonds. On ..mu..-Bondapak C/sub 18/, the presence or absence of a nonaromatic ring is of added importance.« less

  19. Production of Monosugars from Lignocellulosic Biomass in Molten Salt Hydrates: Process Design and Techno-Economic Analysis

    PubMed Central

    2017-01-01

    ZnCl2 hydrate, the main molten salt used in biomass conversion, combined with low concentration HCl is an excellent solvent for the dissolution and hydrolysis of the carbohydrates present in lignocellulosic biomass. The most recalcitrant carbohydrate, cellulose, is dissolved in a residence time less than 1 h under mild conditions without significant degradation. This technology is referred to as BIOeCON-solvent technology. Separation of the sugars from the solution is the main challenge. The earlier conclusion regarding the potential of zeolite beta for selective adsorption has been used as the basis of a scale-up study. The technology of choice is continuous chromatographic separation (e.g., simulated moving bed, SMB). The sugar monomers are separated from the sugar oligomers, allowing the production of monosugars at high yield, using water as an eluent. Results of a pilot plant study are presented showing a stable operation at high selectivity. Several process designs are discussed, and the techno-economic performance of the BIOeCON-solvent technology is demonstrated by comparison with the state-of-the-art technology of NREL (National Renewable Energy Laboratory), which is based on enzymatic conversion of cellulose. It is concluded that the BIOeCON-solvent technology is technically and economically viable and is competitive to the NREL process. Because the BIOeCON-solvent process is in an early stage of development and far from fully optimized, it has the potential to outperform the existing processes. PMID:29170600

  20. Production of Monosugars from Lignocellulosic Biomass in Molten Salt Hydrates: Process Design and Techno-Economic Analysis.

    PubMed

    van den Bergh, Johan; Babich, Igor V; O'Connor, Paul; Moulijn, Jacob A

    2017-11-15

    ZnCl 2 hydrate, the main molten salt used in biomass conversion, combined with low concentration HCl is an excellent solvent for the dissolution and hydrolysis of the carbohydrates present in lignocellulosic biomass. The most recalcitrant carbohydrate, cellulose, is dissolved in a residence time less than 1 h under mild conditions without significant degradation. This technology is referred to as BIOeCON-solvent technology. Separation of the sugars from the solution is the main challenge. The earlier conclusion regarding the potential of zeolite beta for selective adsorption has been used as the basis of a scale-up study. The technology of choice is continuous chromatographic separation (e.g., simulated moving bed, SMB). The sugar monomers are separated from the sugar oligomers, allowing the production of monosugars at high yield, using water as an eluent. Results of a pilot plant study are presented showing a stable operation at high selectivity. Several process designs are discussed, and the techno-economic performance of the BIOeCON-solvent technology is demonstrated by comparison with the state-of-the-art technology of NREL (National Renewable Energy Laboratory), which is based on enzymatic conversion of cellulose. It is concluded that the BIOeCON-solvent technology is technically and economically viable and is competitive to the NREL process. Because the BIOeCON-solvent process is in an early stage of development and far from fully optimized, it has the potential to outperform the existing processes.

  1. Seeking organic compounds on Mars : in situ analysis of organic compounds by Gas Chromatography-Mass Spectrometry on MOMA experiment

    NASA Astrophysics Data System (ADS)

    Buch, A.; Freissinet, C.; Sternberg, R.; Pinnick, V.; Szopa, C.; Coll, P. J.; Rodier, C.; Garnier, C.; Steininger, H.; Moma Team

    2010-12-01

    The search for signs of past or present life is one of the primary goals of future Mars exploratory missions. The Mars Organic Molecule Analyzer (MOMA) experiment of the ExoMars mission (set to launch 2016-2018) is a joint venture by the European Space Agency and NASA to develop a sensitive detector for organics on Mars. MOMA will be one of the main analytical instruments aboard the ExoMars Rover aimed at characterizing possible “signs-of-life molecules” in the Martian environment such as amino acids, carboxylic acids, nucleobases or polycyclic aromatic hydrocarbons (PAHs). With the aim to separate and detect organic compounds from Martian soil, the French MOMA team has built a gas chromatograph able to work in standalone mode by using a TCD detector. The gas chromatograph can also be coupled with an ion trap mass spectrometer developed by the US MOMA team. Moreover, a GC-MS compatible sample processing system (SPS) allowing the extraction and the chemical transformation of the organic compounds from the soil, that fits within space flight conditions, has also been developed. The sample processing is performed in an oven, dedicated to the MOMA experiment containing the solid sample (50-100mg). The internal temperature of oven can be ranged from 20 to 1000 °C which allows for pyrolysis, thermochemolysis or derivatization. The organic extraction step is achieved by using thermodesorption in the range of 100 to 300°C for 0.5 to 5 min. Then, the chemical derivatization and/or thermochemolysis of the extracted compounds is performed directly on the soil with a mixture of MTBSTFA-DMF, TMAH or DMF-DMA solution when enantiomeric separation is required. By decreasing the polarity of the target molecules, this step allows for their volatilization at a temperature below 250°C without any chemical degradation. Once derivatized, the volatile target molecules are trapped in a cold chemical trap and promptly desorbed into the gas chromatograph coupled to the mass spectrometer. Preliminary tests, performed on several analogue soils such as Atacama soil, with the MOMA SPS-GC/MS experiment demonstrated the capability to detect organic compounds such as amino and carboxylic acids with sensitivities below the ppm level.

  2. Ion chromatography with the indirect ultraviolet detection of alkali metal ions and ammonium using imidazolium ionic liquid as ultraviolet absorption reagent and eluent.

    PubMed

    Liu, Yong-Qiang; Yu, Hong

    2016-08-01

    Indirect ultraviolet detection was conducted in ultraviolet-absorption-agent-added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li(+) , Na(+) , K(+) , and NH4 (+) was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography-indirect ultraviolet detection. The successful separation and detection of Li(+) , Na(+) , K(+) , and NH4 (+) within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Mass spectrometry based proteomics: existing capabilities and future directions

    PubMed Central

    Angel, Thomas E.; Aryal, Uma K.; Hengel, Shawna M.; Baker, Erin S.; Kelly, Ryan T.; Robinson, Errol W.; Smith, Richard D.

    2012-01-01

    Mass spectrometry (MS)-based proteomics is emerging as a broadly effective means for identification, characterization, and quantification of proteins that are integral components of the processes essential for life. Characterization of proteins at the proteome and sub-proteome (e.g., the phosphoproteome, proteoglycome, or degradome/peptidome) levels provides a foundation for understanding fundamental aspects of biology. Emerging technologies such as ion mobility separations coupled with MS and microchip-based-proteome measurements combined with MS instrumentation and chromatographic separation techniques, such as nanoscale reversed phase liquid chromatography and capillary electrophoresis, show great promise for both broad undirected and targeted highly sensitive measurements. MS-based proteomics is increasingly contribute to our understanding of the dynamics, interactions, and roles that proteins and peptides play, advancing our understanding of biology on a systems wide level for a wide range of applications including investigations of microbial communities, bioremediation, and human health. PMID:22498958

  4. Chromatographic resolution of a salt into its parent acid and base constituents.

    PubMed

    Davankov, Vadim; Tsyurupa, Maria

    2006-12-08

    Based on the results of the earlier proposed process of separation of mixtures of mineral electrolytes by size-exclusion chromatography (SEC), it has been suggested that a mineral salt must spontaneously resolve, at least partially, into its parent acid and base constituents, provided that the separating media discriminates the anion and cation of the salt according to their size. Indeed, migration of a zone of an aqueous salt solution through a bed of neutral nanoporous hypercrosslinked polystyrene-type packing was shown to result in the generation of acidic and alkaline effluent fractions. The principle of spontaneous salt resolution has been extended to other types of discriminating interactions between the stationary phase and the two ions of the salt. The idea was exemplified by the resolution of ammonium acetate, due to hydrophobic retention of the acetate, into fractions enriched in ammoniac and then acetic acid.

  5. A comparative evaluation of different ionic liquids for arsenic species separation and determination in wine varietals by liquid chromatography - hydride generation atomic fluorescence spectrometry.

    PubMed

    Castro Grijalba, Alexander; Fiorentini, Emiliano F; Martinez, Luis D; Wuilloud, Rodolfo G

    2016-09-02

    The application of different ionic liquids (ILs) as modifiers for chromatographic separation and determination of arsenite [As(III)], arsenate [As(V)], dimethylarsonic acid (DMA) and monomethylarsonic acid (MMA) species in wine samples, by reversed-phase high performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry detection (RP-HPLC-HG-AFS) was studied in this work. Several factors influencing the chromatographic separation of the As species, such as pH of the mobile phase, buffer solution concentration, buffer type, IL concentration and length of alkyl groups in ILs were evaluated. The complete separation of As species was achieved using a C18 column in isocratic mode with a mobile phase composed of 0.5% (v/v) 1-octyl-3-methylimidazolium chloride ([C8mim]Cl) and 5% (v/v) methanol at pH 8.5. A multivariate methodology was used to optimize the variables involved in AFS detection of As species after they were separated by HPLC. The ILs showed remarkable performance for the separation of As species, which was obtained within 18min with a resolution higher than 0.83. The limits of detection for As(III), As(V), MMA and DMA were 0.81, 0.89, 0.62 and 1.00μg As L(-1). The proposed method was applied for As speciation analysis in white and red wine samples originated from different grape varieties. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Evaluation and application of a mixed-mode chromatographic stationary phase in two-dimensional liquid chromatography for the separation of traditional Chinese medicine.

    PubMed

    Wei, Zhishen; Fu, Qing; Cai, Jianfeng; Huan, Liyun; Zhao, Jianchao; Shi, Hui; Jin, Yu; Liang, Xinmiao

    2016-06-01

    In this study, two mixed-mode chromatography stationary phases (C8SAX and C8SCX) were evaluated and used to establish a two-dimensional liquid chromatography system for the separation of traditional Chinese medicine. The chromatographic properties of the mixed-mode columns were systematically evaluated by comparing with other three columns of C8, strong anion exchanger, and strong cation exchanger. The result showed that C8SAX and C8SCX had a mixed-mode retention mechanism including electrostatic interaction and hydrophobic interaction. Especially, they were suitable for separating acidic and/or basic compounds and their separation selectivities could be easily adjusted by changing pH value. Then, several off-line 2D-LC systems based on the C8SAX in the first dimension and C8SAX, C8SCX, or C8 columns in the second dimension were developed to analyze a traditional Chinese medicine-Uncaria rhynchophylla. The two-dimensional liquid chromatography system of C8SAX (pH 3.0) × C8SAX (pH 6.0) exhibited the most effective peak distribution. Finally, fractions of U. rhynchophylla prepared from the first dimension were successfully separated on the C8SAX column with a gradient pH. Thus, the mixed-mode stationary phase could provide a platform to separate the traditional Chinese medicine in practical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system.

    PubMed

    Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger

    2013-10-01

    A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

  8. Ionic Liquid-Liquid Chromatography: A New General Purpose Separation Methodology.

    PubMed

    Brown, Leslie; Earle, Martyn J; Gîlea, Manuela A; Plechkova, Natalia V; Seddon, Kenneth R

    2017-08-10

    Ionic liquids can form biphasic solvent systems with many organic solvents and water, and these solvent systems can be used in liquid-liquid separations and countercurrent chromatography. The wide range of ionic liquids that can by synthesised, with specifically tailored properties, represents a new philosophy for the separation of organic, inorganic and bio-based materials. A customised countercurrent chromatograph has been designed and constructed specifically to allow the more viscous character of ionic liquid-based solvent systems to be used in a wide variety of separations (including transition metal salts, arenes, alkenes, alkanes, bio-oils and sugars).

  9. Nanostructured pillars based on vertically aligned carbon nanotubes as the stationary phase in micro-CEC.

    PubMed

    Wu, Ren-Guei; Yang, Chung-Shi; Wang, Pen-Cheng; Tseng, Fan-Gang

    2009-06-01

    We present a micro-CEC chip carrying out a highly efficient separation of dsDNA fragments through vertically aligned multi-wall carbon nanotubes (MWCNTs) in a microchannel. The vertically aligned MWCNTs were grown directly in the microchannel to form straight nanopillar arrays as ordered and directional chromatographic supports. 1-Pyrenedodecanoic acid was employed for the surface modification of the MWCNTs' stationary phase to adsorb analytes by hydrophobic interactions. This device was used for separating dsDNA fragments of three different lengths (254, 360, and 572 bp), and fluorescence detection was employed to verify the electrokinetic transport in the MWCNT array. The micro-CEC separation of the three compounds was achieved in less than 300 s at a field strength of 66 V/cm due to superior laminar flow patterns and a lower flow resistance resulting from the vertically aligned MWCNTs being used as the stationary phase medium. In addition, a fivefold reduction of band broadening was obtained when the analyte was separated by the chromatographic MWCNT array channel instead of the CE channel. From all of the results, we suggest that an in situ grown and directional MWCNT array can potentially be useful for preparing more diversified forms of stationary phases for vertically efficient chip-based electrochromatography.

  10. Application of micro-TLC to the total antioxidant potential (TAP) measurement.

    PubMed

    Głód, Bronisław K; Wantusiak, Paweł M; Piszcz, Paweł; Lewczuk, Elwira; Zarzycki, Paweł K

    2015-04-15

    DPPH is commonly applied for estimation of antioxidant capacity of single and complex biological samples, and changes colour from purple to yellow during reduction to DPPH-H. Importantly, for some samples, for example coloured foods, such reaction cannot be used because of interference from pigments. Therefore, the number of reported quantitative protocols involving off- or on-line sample reaction with DPPH are based on chromatographic separation of target components. In typical planar chromatographic assay, developed plates are sprayed with DPPH solution for antioxidant screening. Such approach enables simple visualisation of separated spots exhibiting antioxidant activities, but unfortunately, such procedure may also give the misleading signal for coloured spots. In the present communication we examined a new approach for measuring antioxidant capacity using quantitative analysis of DPPH and DPPH-H molecules after reaction with the sample, and then separated from the interfering compounds by micro-thin-layer chromatography. Particularly, the antioxidant capacities of coloured food samples (such as herbs and meads) were determined and the results compared with those obtained using the classical photometric assay. The main advantages of the new micro-TLC assay are (i) low cost, (ii) multiple measurements, (iii) short analysis time, (iv) simplification of sample preparation and (v) effective separation of DPPH signal from interfering compounds. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Label-assisted mass spectrometry for the acceleration of reaction discovery and optimization

    NASA Astrophysics Data System (ADS)

    Cabrera-Pardo, Jaime R.; Chai, David I.; Liu, Song; Mrksich, Milan; Kozmin, Sergey A.

    2013-05-01

    The identification of new reactions expands our knowledge of chemical reactivity and enables new synthetic applications. Accelerating the pace of this discovery process remains challenging. We describe a highly effective and simple platform for screening a large number of potential chemical reactions in order to discover and optimize previously unknown catalytic transformations, thereby revealing new chemical reactivity. Our strategy is based on labelling one of the reactants with a polyaromatic chemical tag, which selectively undergoes a photoionization/desorption process upon laser irradiation, without the assistance of an external matrix, and enables rapid mass spectrometric detection of any products originating from such labelled reactants in complex reaction mixtures without any chromatographic separation. This method was successfully used for high-throughput discovery and subsequent optimization of two previously unknown benzannulation reactions.

  12. Fraction-storage unit for drug-identification system

    NASA Technical Reports Server (NTRS)

    Campen, C. F.; Stuart, J. L.

    1976-01-01

    Device, connecting outputs of all gas chromatographs to single, relatively inexpensive IR spectrometer, reduces costs of system. Storage unit provides buffer storage of samples until infrared spectrometer is ready to accept them. Storage unit can be used to separate overlapping peaks.

  13. Ultra-trace level analysis of morpholine, cyclohexylamine, and diethylaminoethanol in steam condensate by gas chromatography with multi-mode inlet, and flame ionization detection.

    PubMed

    Luong, J; Shellie, R A; Cortes, H; Gras, R; Hayward, T

    2012-03-16

    Steam condensate water treatment is a vital and integral part of the overall cooling water treatment process. Steam condensate often contains varying levels of carbon dioxide and oxygen which acts as an oxidizer. Carbon dioxide forms corrosive carbonic acid when dissolved in condensed steam. To neutralize the harmful effect of the carbonic acid, volatile amine compounds such as morpholine, cyclohexylamine, and diethylaminoethanol are often employed as part of a strategy to control corrosion in the water treatment process. Due to the high stability of these compounds in a water matrix, the indirect addition of such chemicals into the process via steam condensate often results in their presence throughout the process and even into the final product. It is therefore important to understand the impact of these chemicals and their fate within a chemical plant. The ability to analyze such compounds by gas chromatography has historically been difficult due to the lack of chromatographic system inertness at the trace level concentrations especially in an aqueous matrix. Here a highly sensitive, practical, and reliable gas chromatographic approach is described for the determination of morpholine, cyclohexylamine, and diethylaminoethanol in steam condensate at the part-per-billion (ppb) levels. The approach does not require any sample enrichment or derivatization. The technique employs a multi-mode inlet operating in pulsed splitless mode with programmed inlet temperature for sample introduction, an inert base-deactivated capillary column for solute separation and flame ionization detection. Chromatographic performance was further enhanced by the incorporation of 2-propanol as a co-solvent. Detection limits for morpholine, cyclohexylamine, diethylaminoethanol were established to be 100 ppb (v/v), with relative standard deviations (RSD) of less than 6% at the 95% confidence level (n=20) and a percent recovery of 96% or higher for the solutes of interest over a range of 0.1-100 ppm (v/v). A complete analysis can be conducted in less than 10 min. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Separation of oil-water-sludge emulsions coming from palm oil mill process through microwave techniques.

    PubMed

    Pérez-Páez, Rocío; Catalá-Civera, José Manuel; García-Baños, Beatriz; Castillo, Edgar F; Bastos, Johanna M; Zambrano, Luz S

    2008-01-01

    The palm oil mills extraction process requires the separation of oil-water-sludge emulsions. For this purpose, the use of sedimentation and/or centrifugation techniques have been required until now. However, significant losses persist in different process flows and new methods are needed to further decrease them, such as methods based on electromagnetic waves application. In the study, emulsions obtained from two flow processes, namely press liquor stream (PL) and recovered stream of the centrifugal step (RC), were exposed to microwave radiation with different exposure times. In the case of the press liquor stream, different oil/water dilution ratios were also studied. The sedimentation speed and efficiency were studied for the irradiated samples and compared to those obtained for the same fluids with no radiation. Also, chromatographic tests were performed on the recovered oil to determine the effect on the oil quality after microwave radiation. The obtained results allow us to conclude that microwave exposure during periods below 1 minute lead to better sedimentation speed and efficiency. It was observed that microwaves facilitate the break of the charges and polarities balances in the emulsions at considerably lower temperatures than the corresponding in the conventional process, without affecting the recovered oil quality.

  15. Preparation and evaluation of silica-UIO-66 composite as liquid chromatographic stationary phase for fast and efficient separation.

    PubMed

    Yan, Zhiming; Zheng, Jiangnan; Chen, Jinfeng; Tong, Ping; Lu, Minghua; Lin, Zian; Zhang, Lan

    2014-10-31

    A silica-UIO-66 composite was fabricated by a simple hydrothermal method and then applied as liquid chromatographic stationary phase for fast and efficient separation. X-ray diffraction patterns showed the presence of UIO-66 crystals in the silica-UIO-66 composites; while scanning electron microscope (SEM) images revealed that silica-UIO-66 composites were a homogeneous mixture of silica bead and UIO-66 crystals. A variety of substituted aromatics, chlorobenzene compounds and polycyclic aromatic hydrocarbons (PAHs) were used to evaluate the retention properties of the silica-UIO-66 composite packed column. Under the optimized conditions, baseline separation of ethylbenzene (EB) and styrene was obtained with high resolution and short retention time. In addition, the silica-UIO-66 composite packed column also showed some advantages in separation of positional isomers, with which baseline separation of EB and xylene, chlorotoluene and dichlorobenzene isomers was achieved. Moreover, the retention mechanisms of these compounds were also discussed in detail. The relative standard deviations (RSDs) for the separation of EB and xylene, chlorotoluene and dichlorobenzene isomers, as well as EB and styrene were 0.42-0.9%, 1.0-1.9%, 0.75-2.0%, and 0.9-2.1% for the retention time, peak area, peak height, and half peak width, respectively. The column efficiencies for EB, p-chlorotoluene, p-dichlorobenzene and styrene were 8780, 9060, 9990 and 5130 plates/m. The successful applications suggested high potentials of silica-MOFs composite as stationary phase for fast and efficient liquid chromatography separation. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Separation and purification of five alkaloids from Aconitum duclouxii by counter-current chromatography.

    PubMed

    Wang, Yarong; Cai, Shining; Chen, Yang; Deng, Liang; Zhou, Xumei; Liu, Jia; Xu, Xin; Xia, Qiang; Lin, Mao; Zhang, Jili; Huang, Weili; Wang, Wenjun; Xiang, Canhui; Cui, Guozhen; Du, Lianfeng; He, Huan; Qi, Baohui

    2015-07-01

    C19 -diterpenoid alkaloids are the main components of Aconitum duclouxii Levl. The process of separation and purification of these compounds in previous studies was tedious and time consuming, requiring multiple chromatographic steps, thus resulted in low recovery and high cost. In the present work, five C19 -diterpenoid alkaloids, namely, benzoylaconine (1), N-deethylaconitine (2), aconitine (3), deoxyaconitine (4), and ducloudine A (5), were efficiently prepared from A. duclouxii Levl (Aconitum L.) by ethyl acetate extraction followed with counter-current chromatography. In the process of separation, the critical conditions of counter-current chromatography were optimized. The two-phase solvent system composed of n-hexane/ethyl acetate/methanol/water/NH3 ·H2 O (25%) (1:1:1:1:0.1, v/v) was selected and 148.2 mg of 1, 24.1 mg of 2, 250.6 mg of 3, 73.9 mg of 4, and 31.4 mg of 5 were obtained from 1 g total Aconitum alkaloids extract, respectively, in a single run within 4 h. Their purities were found to be 98.4, 97.2, 98.2, 96.8, and 96.6%, respectively, by ultra-high performance liquid chromatography analysis. The presented separation and purification method was simple, fast, and efficient, and the obtained highly pure alkaloids are suitable for biochemical and toxicological investigation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. High-throughput process development: I. Process chromatography.

    PubMed

    Rathore, Anurag S; Bhambure, Rahul

    2014-01-01

    Chromatographic separation serves as "a workhorse" for downstream process development and plays a key role in removal of product-related, host cell-related, and process-related impurities. Complex and poorly characterized raw materials and feed material, low feed concentration, product instability, and poor mechanistic understanding of the processes are some of the critical challenges that are faced during development of a chromatographic step. Traditional process development is performed as trial-and-error-based evaluation and often leads to a suboptimal process. High-throughput process development (HTPD) platform involves an integration of miniaturization, automation, and parallelization and provides a systematic approach for time- and resource-efficient chromatography process development. Creation of such platforms requires integration of mechanistic knowledge of the process with various statistical tools for data analysis. The relevance of such a platform is high in view of the constraints with respect to time and resources that the biopharma industry faces today. This protocol describes the steps involved in performing HTPD of process chromatography step. It described operation of a commercially available device (PreDictor™ plates from GE Healthcare). This device is available in 96-well format with 2 or 6 μL well size. We also discuss the challenges that one faces when performing such experiments as well as possible solutions to alleviate them. Besides describing the operation of the device, the protocol also presents an approach for statistical analysis of the data that is gathered from such a platform. A case study involving use of the protocol for examining ion-exchange chromatography of granulocyte colony-stimulating factor (GCSF), a therapeutic product, is briefly discussed. This is intended to demonstrate the usefulness of this protocol in generating data that is representative of the data obtained at the traditional lab scale. The agreement in the data is indeed very significant (regression coefficient 0.93). We think that this protocol will be of significant value to those involved in performing high-throughput process development of process chromatography.

  18. Modifier mass transfer kinetic effect in the performance of solvent gradient simulated moving bed (SG-SMB) process

    NASA Astrophysics Data System (ADS)

    Câmara, L. D. T.

    2015-09-01

    The solvent-gradient simulated moving bed process (SG-SMB) is the new tendency in the performance improvement if compared to the traditional isocratic solvent conditions. In such SG-SMB separation process the modulation of the solvent strength leads to significant increase in the purities and productivity followed by reduction in the solvent consumption. A stepwise modelling approach was utilized in the representation of the interconnected chromatographic columns of the system combined with lumped mass transfer models between the solid and liquid phase. The influence of the solvent modifier was considered applying the Abel model which takes into account the effect of modifier volume fraction over the partition coefficient. The modelling and simulations were carried out and compared to the experimental SG-SMB separation of the amino acids phenylalanine and tryptophan. A lumped mass transfer kinetic model was applied for both the modifier (ethanol) as well as the solutes. The simulation results showed that such simple and global mass transfer models are enough to represent all the mass transfer effect between the solid adsorbent and the liquid phase. The separation performance can be improved reducing the interaction or the mass transfer kinetic effect between the solid adsorbent phase and the modifier. The simulations showed great agreement fitting the experimental data of the amino acids concentrations both at the extract as well as at the raffinate.

  19. A high-throughput 2D-analytical technique to obtain single protein parameters from complex cell lysates for in silico process development of ion exchange chromatography.

    PubMed

    Kröner, Frieder; Elsäßer, Dennis; Hubbuch, Jürgen

    2013-11-29

    The accelerating growth of the market for biopharmaceutical proteins, the market entry of biosimilars and the growing interest in new, more complex molecules constantly pose new challenges for bioseparation process development. In the presented work we demonstrate the application of a multidimensional, analytical separation approach to obtain the relevant physicochemical parameters of single proteins in a complex mixture for in silico chromatographic process development. A complete cell lysate containing a low titre target protein was first fractionated by multiple linear salt gradient anion exchange chromatography (AEC) with varying gradient length. The collected fractions were subsequently analysed by high-throughput capillary gel electrophoresis (HT-CGE) after being desalted and concentrated. From the obtained data of the 2D-separation the retention-volumes and the concentration of the single proteins were determined. The retention-volumes of the single proteins were used to calculate the related steric-mass action model parameters. In a final evaluation experiment the received parameters were successfully applied to predict the retention behaviour of the single proteins in salt gradient AEC. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Identification of homemade inorganic explosives by ion chromatographic analysis of post-blast residues.

    PubMed

    Johns, Cameron; Shellie, Robert A; Potter, Oscar G; O'Reilly, John W; Hutchinson, Joseph P; Guijt, Rosanne M; Breadmore, Michael C; Hilder, Emily F; Dicinoski, Greg W; Haddad, Paul R

    2008-02-29

    Anions and cations of interest for the post-blast identification of homemade inorganic explosives were separated and detected by ion chromatographic (IC) methods. The ionic analytes used for identification of explosives in this study comprised 18 anions (acetate, benzoate, bromate, carbonate, chlorate, chloride, chlorite, chromate, cyanate, fluoride, formate, nitrate, nitrite, perchlorate, phosphate, sulfate, thiocyanate and thiosulfate) and 12 cations (ammonium, barium(II), calcium(II), chromium(III), ethylammonium, magnesium(II), manganese(II), methylammonium, potassium(I), sodium(I), strontium(II), and zinc(II)). Two IC separations are presented, using suppressed IC on a Dionex AS20 column with potassium hydroxide as eluent for anions, and non-suppressed IC for cations using a Dionex SCS 1 column with oxalic acid/acetonitrile as eluent. Conductivity detection was used in both cases. Detection limits for anions were in the range 2-27.4ppb, and for cations were in the range 13-115ppb. These methods allowed the explosive residue ions to be identified and separated from background ions likely to be present in the environment. Linearity (over a calibration range of 0.05-50ppm) was evaluated for both methods, with r(2) values ranging from 0.9889 to 1.000. Reproducibility over 10 consecutive injections of a 5ppm standard ranged from 0.01 to 0.22% relative standard deviation (RSD) for retention time and 0.29 to 2.16%RSD for peak area. The anion and cation separations were performed simultaneously by using two Dionex ICS-2000 chromatographs served by a single autoinjector. The efficacy of the developed methods was demonstrated by analysis of residue samples taken from witness plates and soils collected following the controlled detonation of a series of different inorganic homemade explosives. The results obtained were also confirmed by parallel analysis of the same samples by capillary electrophoresis (CE) with excellent agreement being obtained.

  1. Design of a portable gas chromatography with a conducting polymer nanocomposite detector device and a method to analyze a gas mixture.

    PubMed

    Pirsa, Sajad

    2017-04-01

    A portable chromatography device and a method were developed to analyze a gas mixture. The device comprises a chromatographic column for separating components of a sample of the gas mixture. It has an air pump coupled to the inlet of a chromatographic column for pumping air and an injector coupled to the inlet of chromatographic column for feeding the sample using the air as a carrier gas. A detector is arranged downstream from and coupled to the outlet of the chromatographic column. The detector is a nanostructure semiconductive microfiber. The device further comprises an evaluation unit arranged and configured to evaluate each detected component to determine the concentration. The designed portable system was used for simultaneous detection of amines. The possibility of applying dispersive liquid-liquid microextraction for the determination of analytes in trace levels is demonstrated. The reproducibility of this method is acceptable, and good standard deviations were obtained. The relative standard deviation value is less than 6% for all analytes. Finally, the method was successfully applied to the extraction and determination of analytes in water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A chromatographic objective function to characterise chromatograms with unknown compounds or without standards available.

    PubMed

    Alvarez-Segura, T; Gómez-Díaz, A; Ortiz-Bolsico, C; Torres-Lapasió, J R; García-Alvarez-Coque, M C

    2015-08-28

    Getting useful chemical information from samples containing many compounds is still a challenge to analysts in liquid chromatography. The highest complexity corresponds to samples for which there is no prior knowledge about their chemical composition. Computer-based methodologies are currently considered as the most efficient tools to optimise the chromatographic resolution, and further finding the optimal separation conditions. However, most chromatographic objective functions (COFs) described in the literature to measure the resolution are based on mathematical models fitted with the information obtained from standards, and cannot be applied to samples with unknown compounds. In this work, a new COF based on the automatic measurement of the protruding part of the chromatographic peaks (or peak prominences) that indicates the number of perceptible peaks and global resolution, without the need of standards, is developed. The proposed COF was found satisfactory with regard to the peak purity criterion when applied to artificial peaks and simulated chromatograms of mixtures built using the information of standards. The approach was applied to mixtures of drugs containing unknown impurities and degradation products and to extracts of medicinal herbs, eluted with acetonitrile-water mixtures using isocratic and gradient elution. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Lipidomics in triacylglycerol and cholesteryl ester oxidation.

    PubMed

    Kuksis, Arnis

    2007-05-01

    Although direct mass spectrometry is capable of identification the major molecular species of lipids in crude total lipid extracts, prior chromatographic isolation is necessary for detection and identification of the minor components. This is especially important for the analysis of the oxolipids, which usually occur in trace amounts in the total lipid extract, and require prior isolation for detailed analysis. Both thin-layer chromatography and adsorption cartridges provide effective means for isolation and enrichment of lipid classes, while gas-liquid chromatography and high performance liquid chromatography with on-line mass spectrometry permit further separation and identification of molecular species. Prior chromatographic resolution is absolutely necessary for the identification of isobaric and chiral molecules, which mass spectrometry/mass spectrometry (MS/MS) cannot distinguish. Both gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry applications may require the preparation of derivatives in order to improve the chromatographic and mass spectrometric properties of the oxolipids which is a small inconvenience for securing analytical reliability. The following chapter reviews the advantages and necessity of combined chromatographic-mass spectrometric approaches to successful identification and quantification of molecular species of oxoacylglycerols and oxocholesteryl esters in in-vitro model studies of lipid peroxidation and in the analyses of oxolipids recovered from tissues.

  4. Lime application for the efficient production of nutraceutical glucooligosaccharides from Leuconostoc mesenteroides NRRL B-742 (ATCC13146).

    PubMed

    Moon, Young Hwan; Madsen, Lee; Chung, Chang-Ho; Kim, Doman; Day, Donal F

    2015-02-01

    We have previously demonstrated the production of glucooligosaccharides via a fermentation of sucrose with Leuconostoc mesenteroides NRRL B-742 using sodium hydroxide (NaOH) to control the pH. Because NaOH is expensive, we sought to minimize the cost of our process by substituting hydrated lime and saccharate of lime (lime sucrate) in its place. The yield of glucooligosaccharides using either 5 % lime (41.4 ± 0.5 g/100 g) or 5 % lime sucrate (40.0 ± 1.4 g/100 g) were both similar to the NaOH control (42.4 ± 1.5 g/100 g). Based on this, it appears that the cost associated with pH control in our process can be reduced by a factor of approximately 2.4 using lime instead of NaOH. Because our chromatographic stage is based on a Ca(2+)-form resin to separate glucooligosaccharides, the use of lime not only negates the need for costly de-salting via ion-exchange (elimination of two ion-exchange sections) prior to separation, but also greatly reduces the resin regeneration cost.

  5. Novel stationary phases based on asphaltenes for gas chromatography.

    PubMed

    Boczkaj, Grzegorz; Momotko, Malwina; Chruszczyk, Dorota; Przyjazny, Andrzej; Kamiński, Marian

    2016-07-01

    We present the results of investigations on the possibility of the application of the asphaltene fraction isolated from the oxidized residue from vacuum distillation of crude oil as a stationary phase for gas chromatography. The results of the investigation revealed that the asphaltene stationary phases can find use for the separation of a wide range of volatile organic compounds. The experimental values of Rohrschneider/McReynolds constants characterize the asphaltenes as stationary phases of medium polarity and selectivity similar to commercially available phases based on alkyl phthalates. Isolation of asphaltenes from the material obtained under controlled process conditions allows the production of a stationary phase having reproducible sorption properties and chromatographic columns having the same selectivity. Unique selectivity and high thermal stability make asphaltenes attractive as a material for stationary phases for gas chromatography. A low production cost from a readily available raw material (oxidized petroleum bitumens) is an important economic factor in case of application of the asphaltene stationary phases for preparative and process separations. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Conversion of geothermal waste to commercial products including silica

    DOEpatents

    Premuzic, Eugene T.; Lin, Mow S.

    2003-01-01

    A process for the treatment of geothermal residue includes contacting the pigmented amorphous silica-containing component with a depigmenting reagent one or more times to depigment the silica and produce a mixture containing depigmented amorphous silica and depigmenting reagent containing pigment material; separating the depigmented amorphous silica and from the depigmenting reagent to yield depigmented amorphous silica. Before or after the depigmenting contacting, the geothermal residue or depigmented silica can be treated with a metal solubilizing agent to produce another mixture containing pigmented or unpigmented amorphous silica-containing component and a solubilized metal-containing component; separating these components from each other to produce an amorphous silica product substantially devoid of metals and at least partially devoid of pigment. The amorphous silica product can be neutralized and thereafter dried at a temperature from about 25.degree. C. to 300.degree. C. The morphology of the silica product can be varied through the process conditions including sequence contacting steps, pH of depigmenting reagent, neutralization and drying conditions to tailor the amorphous silica for commercial use in products including filler for paint, paper, rubber and polymers, and chromatographic material.

  7. Analysis of processing contaminants in edible oils. Part 2. Liquid chromatography-tandem mass spectrometry method for the direct detection of 3-monochloropropanediol and 2-monochloropropanediol diesters.

    PubMed

    MacMahon, Shaun; Begley, Timothy H; Diachenko, Gregory W

    2013-05-22

    A method was developed and validated for the detection of fatty acid diesters of 2-monochloropropanediol (2-MCPD) and 3-monochloropropanediol (3-MCPD) in edible oils. These analytes are potentially carcinogenic chemical contaminants formed during edible oil processing. After separation from oil matrices using a two-step solid-phase extraction (SPE) procedure, the target compounds are quantitated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). The first chromatographic conditions have been developed that separate intact diesters of 2-MCPD and 3-MCPD, allowing for their individual quantitation. The method has been validated for 28 3-MCPD diesters of lauric, myristic, palmitic, linolenic, linoleic, oleic, and stearic acids in coconut, olive, and palm oils, as well as 3 2-MCPD diesters, using an external calibration curve. The range of average recoveries and relative standard deviations (RSDs) across the three oil matrices at three spiking concentrations are 88-118% (2-16% RSD) with maximum limits of quantitation of 30 ng/g (ppb).

  8. ANALYSIS OF POLYCYCLIC AROMATIC HYDROCARBONS BY ION TRAP TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    An ion-trap mass spectrometer with a wave board and tandem mass spectrometry software was used to analyze gas chromatographically separated polycyclic aromatic hydrocarbons (PAHs) by using collision-induced dissociation (CID). The nonresonant (multiple collision) mode was used to...

  9. ANALYSIS OF VOLATILES AND SEMIVOLATILES BY DIRECT AQUEOUS INJECTION

    EPA Science Inventory

    Direct aqueous injection analysis (DAI) with gas chromatographic separation and ion trap mass spectral detection was used to analyze aqueous samples for g/L levels of 54 volatile and semivolatile compounds, and problematic non-purgeables and non-extractables. The method reduces ...

  10. Separation and Analysis of Citral Isomers.

    ERIC Educational Resources Information Center

    Sacks, Jeff; And Others

    1983-01-01

    Provides background information, procedures, and results of an experiments designed to introduce undergraduates to the technique of steam distillation as a means of isolating thermally sensitive compounds. Chromatographic techniques (HPLC) and mass spectrometric analysis are used in the experiment which requires three laboratory periods. (JN)

  11. Methods and apparatus for analysis of chromatographic migration patterns

    DOEpatents

    Stockham, T.G.; Ives, J.T.

    1993-12-28

    A method and apparatus are presented for sharpening signal peaks in a signal representing the distribution of biological or chemical components of a mixture separated by a chromatographic technique such as, but not limited to, electrophoresis. A key step in the method is the use of a blind deconvolution technique, presently embodied as homomorphic filtering, to reduce the contribution of a blurring function to the signal encoding the peaks of the distribution. The invention further includes steps and apparatus directed to determination of a nucleotide sequence from a set of four such signals representing DNA sequence data derived by electrophoretic means. 16 figures.

  12. High-performance liquid chromatographic method for guanylhydrazone compounds.

    PubMed

    Cerami, C; Zhang, X; Ulrich, P; Bianchi, M; Tracey, K J; Berger, B J

    1996-01-12

    A high-performance liquid chromatographic method has been developed for a series of aromatic guanylhydrazones that have demonstrated therapeutic potential as anti-inflammatory agents. The compounds were separated using octadecyl or diisopropyloctyl reversed-phase columns, with an acetonitrile gradient in water containing heptane sulfonate, tetramethylammonium chloride, and phosphoric acid. The method was used to reliably quantify levels of analyte as low as 785 ng/ml, and the detector response was linear to at least 50 micrograms/ml using a 100 microliters injection volume. The assay system was used to determine the basic pharmacokinetics of a lead compound, CNI-1493, from serum concentrations following a single intravenous injection in rats.

  13. High-pressure liquid chromatographic determination of chlorphenesin carbamate and the beta-isomeric carbamate.

    PubMed

    Beyer, W F

    1976-12-01

    A high-pressure liquid chromatographic assay was developed for the determination of chlorphenesin carbamate and its beta-isomeric carbamate. A single 4-mm i.d. X 30-cm column, prepacked with 10 micrometer fully porous silica gel particles, is used with 3% methanol in 50% water-saturated butyl chloride as the mobile phase. The procedure separates chlorphenesin carbamate from several possible impurities in addition to the beta-isomeric carbamate. The assay was applied to bulk drug and compressed tablets. The relative standard deviations for the assays of chlorphenesin carbamate and the beta-isomer are approximately 1 and 2%, respectively.

  14. Silver ion chromatography for peak resolution enhancement: Application to the preparative separation of two sesquiterpenes using online heart-cutting LC-LC technique.

    PubMed

    Yang, Yang; Zhang, Yongmin; Wei, Chong; Li, Jing; Sun, Wenji

    2018-09-01

    Silver ion chromatography, utilizing columns packed with silver ions bonded to silica gel, has proved to be an invaluable technique for the analysis of some positional isomers. In this work, silver ion chromatography by combination with online heart-cutting LC-LC technique for the preparative separation of two sesquiterpenes positional isomers from a natural product was investigated. On the basis of the evaluation that silver ion content impacts on the separation, the laboratory-made silver ion columns, utilizing silica gel impregnated with 15% silver nitrate as column packing materials, were used for peak resolution improvement of these two isomers and the preparative separation of them in heart-cutting LC-LC. The relationship among the maximal sample load, flow rate and peak resolution in the silver ion column were optimized, and the performance of the silver ion column was compared with conventional C 18 column and silica gel column. Based on the developed chromatographic conditions, online heart-cutting LC-LC chromatographic separation system in combination with a silica gel column and a silver ion column that was applied to preparative separation of these two isomers from a traditional Chinese medicine, Inula racemosa Hook.f., was established. The results showed that the online heart-cutting LC-LC technique by combination of a silica gel column and a silver ion column for the preparative separation of these two positional isomers from this natural plant was superior to the preparative separation performed on a single-column system with C 18 column or silica gel column. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Application of Analytical Quality by Design concept for bilastine and its degradation impurities determination by hydrophilic interaction liquid chromatographic method.

    PubMed

    Terzić, Jelena; Popović, Igor; Stajić, Ana; Tumpa, Anja; Jančić-Stojanović, Biljana

    2016-06-05

    This paper deals with the development of hydrophilic interaction liquid chromatographic (HILIC) method for the analysis of bilastine and its degradation impurities following Analytical Quality by Design approach. It is the first time that the method for bilastine and its impurities is proposed. The main objective was to identify the conditions where an adequate separation in minimal analysis duration could be achieved within a robust region. Critical process parameters which have the most influence on method performance were defined as acetonitrile content in the mobile phase, pH of the aqueous phase and ammonium acetate concentration in the aqueous phase. Box-Behnken design was applied for establishing a relationship between critical process parameters and critical quality attributes. The defined mathematical models and Monte Carlo simulations were used to identify the design space. Fractional factorial design was applied for experimental robustness testing and the method is validated to verify the adequacy of selected optimal conditions: the analytical column Luna(®) HILIC (100mm×4.6mm, 5μm particle size); mobile phase consisted of acetonitrile-aqueous phase (50mM ammonium acetate, pH adjusted to 5.3 with glacial acetic acid) (90.5:9.5, v/v); column temperature 30°C, mobile phase flow rate 1mLmin(-1), wavelength of detection 275nm. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Illuminating the dark side of DOM: A bottom up approach to understanding the structure and composition of DOM.

    NASA Astrophysics Data System (ADS)

    Zito, P.; Tarr, M. A.; Spencer, R. G.; Podgorski, D. C.

    2017-12-01

    Dissolved organic matter (DOM) is one of the most complex natural mixtures on Earth. It is generally comprised of hydrocarbons incorporating a diverse subset of oxygen-containing functional groups along with a small amount of nitrogen, sulfur and phosphorous heteroatoms all of which make it very difficult to chromatographically separate. The only way to directly characterize and quantify these structural and compositional changes is by separating the DOM continuum into defined bins of structure and chemistry. In this study, we take an alternate bottom-up approach that utilizes petroleum to work toward identifying the molecular structures of DOM. Although petroleum is the most structurally diverse mixture in nature, it is almost exclusively comprised of hydrocarbons with only trace quantities of heteroatoms, including oxygen. Here, crude oil was chromatographically separated into bins based on the number of aromatic rings to be used as a starting carbon source. Photochemically produced DOM from these aromatic ring bins provides unique opportunities to gain insight in the compositional controls associated with transport, processing and fate of DOM in natural systems. Here, we present EEMs data from individual ring fractions that were subjected to 24 hours of sunlight to use as a model to fingerprint specific aromatic regions in the DOM fraction. Results illustrate that the 1-, 2-, 3-, 4- and 5- ring fractions exhibit a wide range of structurally dependent excitation and emission spectra. A well-known red-shift in the emission and excitation occurs as the number of rings increase. In order to understand changes in the elemental composition of the data, ultra high-resolution mass spectrometry was used to obtain molecular level information. Together, these data will provide a tool to help understand the relationship of the composition and structure of DOM released into the environment in terms of aromaticity. It is well known that aromaticity is an important indicator of the chemical characteristics of DOM and can be used to explain the role of DOM in environmental processes. Thus, identifying these compounds in terms of aromaticity after photodegradation will provide information about the fate, transport and mechanisms of the photolabile and recalcitrant compounds in the environment.

  17. Renaissance of protein crystallization and precipitation in biopharmaceuticals purification.

    PubMed

    Dos Santos, Raquel; Carvalho, Ana Luísa; Roque, A Cecília A

    The current chromatographic approaches used in protein purification are not keeping pace with the increasing biopharmaceutical market demand. With the upstream improvements, the bottleneck shifted towards the downstream process. New approaches rely in Anything But Chromatography methodologies and revisiting former techniques with a bioprocess perspective. Protein crystallization and precipitation methods are already implemented in the downstream process of diverse therapeutic biological macromolecules, overcoming the current chromatographic bottlenecks. Promising work is being developed in order to implement crystallization and precipitation in the purification pipeline of high value therapeutic molecules. This review focuses in the role of these two methodologies in current industrial purification processes, and highlights their potential implementation in the purification pipeline of high value therapeutic molecules, overcoming chromatographic holdups. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. High-efficiency high performance liquid chromatographic analysis of red wine anthocyanins.

    PubMed

    de Villiers, André; Cabooter, Deirdre; Lynen, Frédéric; Desmet, Gert; Sandra, Pat

    2011-07-22

    The analysis of anthocyanins in natural products is of significant relevance in recent times due to the recognised health benefits associated with their consumption. In red grapes and wines in particular, anthocyanins are known to contribute important properties to the sensory (colour and taste), anti-oxidant- and ageing characteristics. However, the detailed investigation of the alteration of these compounds during wine ageing is hampered by the challenges associated with the separation of grape-derived anthocyanins and their derived products. High performance liquid chromatography (HPLC) is primarily used for this purpose, often in combination with mass spectrometric (MS) detection, although conventional HPLC methods provide incomplete resolution. We have previously demonstrated how on-column inter-conversion reactions are responsible for poor chromatographic efficiency in the HPLC analysis of anthocyanins, and how an increase in temperature and decrease in particle size may improve the chromatographic performance. In the current contribution an experimental configuration for the high efficiency analysis of anthocyanins is derived using the kinetic plot method (KPM). Further, it is shown how analysis under optimal conditions, in combination with MS detection, delivers much improved separation and identification of red wine anthocyanins and their derived products. This improved analytical performance holds promise for the in-depth investigation of these influential compounds in wine during ageing. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Scope of partial least-squares regression applied to the enantiomeric composition determination of ketoprofen from strongly overlapped chromatographic profiles.

    PubMed

    Padró, Juan M; Osorio-Grisales, Jaiver; Arancibia, Juan A; Olivieri, Alejandro C; Castells, Cecilia B

    2015-07-01

    Valuable quantitative information could be obtained from strongly overlapped chromatographic profiles of two enantiomers by using proper chemometric methods. Complete separation profiles where the peaks are fully resolved are difficult to achieve in chiral separation methods, and this becomes a particularly severe problem in case that the analyst needs to measure the chiral purity, i.e., when one of the enantiomers is present in the sample in very low concentrations. In this report, we explore the scope of a multivariate chemometric technique based on unfolded partial least-squares regression, as a mathematical tool to solve this quite frequent difficulty. This technique was applied to obtain quantitative results from partially overlapped chromatographic profiles of R- and S-ketoprofen, with different values of enantioresolution factors (from 0.81 down to less than 0.2 resolution units), and also at several different S:R enantiomeric ratios. Enantiomeric purity below 1% was determined with excellent precision even from almost completely overlapped signals. All these assays were tested on the most demanding condition, i.e., when the minor peak elutes immediately after the main peak. The results were validated using univariate calibration of completely resolved profiles and the method applied to the determination of enantiomeric purity of commercial pharmaceuticals. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Investigation on the preparation and chromatographic behavior of a new para-tert-butylcalix[4]arene-1,2-crown-4 stationary phase for high performance liquid chromatography.

    PubMed

    Hu, Kai; Zhao, Wenjie; Wen, Fuyong; Liu, Junwei; Zhao, Xiaolan; Xu, Zhanhui; Niu, Bailin; Ye, Baoxian; Wu, Yangjie; Zhang, Shusheng

    2011-07-15

    In the present work, a new para-tert-butylcalix[4]arene-1,2-crown-4 bonded silica stationary phase (CBS4-4) was synthesized, structurally characterized, and employed to separate polycyclic aromatic hydrocarbons (PAHs), phenols, aromatic amines, benzoic acid and its derivatives. The chromatographic behaviors of the prepared stationary phase were investigated and compared with ODS. The effects of methanol concentrations on the retention index show that CBS4-4 exhibits high selectivity for the above analytes. The separation mechanisms based on the different interactions between calixarene and the analytes were discussed. With the assistance of quantum chemistry calculation, the interaction Gibbs free energy change ΔG(solv) (in the mobile phase) of p, m and o-phenylenediamine positional isomers and para-tert-butylcalix[4]arene-1,2-crown-4 were obtained. The ΔG(solv) values were consistent with the retention behavior of p, m and o-phenylenediamine on the CBS4-4. According to the chromatographic data, it can be concluded that the selectivity of CBS4-4 for analytes is mainly ascribed to hydrophobic interaction, accompanied by other effects such as hydrogen bonding interaction, π-π and inclusion interaction. The CBS4-4 column has been successfully employed for the analysis of benzoic acid in Sprite drink. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Optimization of chromatographic conditions for determination of aflatoxin B1, B2, G1 and G2 by using liquid chromatography-mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Ramadhaningtyas, Dillani Putri; Aryana, Nurhani; Aristiawan, Yosi; Styarini, Dyah

    2017-11-01

    The optimization of instrument condition and chromatographic separation for analysis of aflatoxin B1, B2, G1 and G2 using liquid chromatography tandem with mass spectrometer detector was conducted in the aim to provide more accurate and reliable analysis results. The aflatoxin known to be serious threat for human health as it is classified as the carcinogenic compounds. The aflatoxin B1, B2, G1 and G2 were selected due to its extensive contamination in various agricultural commodities. The best chromatographic separation was obtained using C-18 column with gradient elution of solvent 5 mM ammonium acetate and 0.1% formic acid in methanol at 7 minutes runtime analysis. The linearity of the detector showed satisfied results as the coefficient determination found to be 0.9994, 0.9996, 0.9998 and 0.9987 for aflatoxin B1, G1, B2, and G2 respectively in the range concentration from 1 to 20 ng/g. The quantifier ion selected for the aflatoxin B1, B2, G1 and G2 was m/z 285.1, 259, 243 and 313 respectively. The instrument precision at these quantifier ions also showed satisfied result with %RSD was around 3.4 to 6.8%. The optimized method present in this study can be used for further sample analysis.

  2. Multi-component immunoaffinity subtraction chromatography: an innovative step towards a comprehensive survey of the human plasma proteome.

    PubMed

    Pieper, Rembert; Su, Qin; Gatlin, Christine L; Huang, Shih-Ting; Anderson, N Leigh; Steiner, Sandra

    2003-04-01

    In order to discover novel protein markers indicative of disease processes or drug effects, the proteomics technology platform most commonly used consists of high resolution protein separation by two-dimensional electrophoresis (2-DE), mass spectrometric identification of proteins from stained gel spots and a bioinformatic data analysis process supported by statistics. This approach has been more successful in profiling proteins and their disease- or treatment-related quantitative changes in tissue homogenates than in plasma samples. Plasma protein display and quantitation suffer from several disadvantages: very high abundance of a few proteins; high heterogeneity of many proteins resulting in long charge trains; crowding of 2-DE separated protein spots in the molecular mass range between 45-80 kD and in the isoelectric point range between 4.5 and 6. Therefore, proteomic technologies are needed that address these problems and particularly allow accurate quantitation of a larger number of less abundant proteins in plasma and other body fluids. The immunoaffinity-based protein subtraction chromatography (IASC) described here removes multiple proteins present in plasma and serum in high concentrations effectively and reproducibly. Applying IASC as an upfront plasma sample preparation process for 2-DE, the protein spot pattern observed in gels changes dramatically and at least 350 additional lower abundance proteins are visualized. Affinity-purified polyclonal antibodies (pAbs) are the immunoaffinity reagents used to specifically remove the abundant proteins such as albumin, immunoglobulin G, immunoglobulin A, transferrin, haptoglobin, alpha-1-antitrypsin, hemopexin, transthyretin, alpha-2-HS glycoprotein, alpha-1-acid glycoprotein, alpha-2-macroglobulin and fibrinogen from human plasma samples. To render the immunoaffinity subtraction procedure recyclable, the pAbs are immobilized and cross-linked on chromatographic matrices. Antibody-coupled matrices specific for one protein each can be pooled to form mixed-bed IASC columns. We show that up to ten affinity-bound plasma proteins with similar solubility characteristics are eluted from a mixed-bed column in one step. This facilitates automated chromatographic processing of plasma samples in high throughput, which is desirable in proteomic disease marker discovery projects.

  3. Purification of coumarin compounds from Cortex fraxinus by adsorption chromatography.

    PubMed

    Yu, Minglan; Sun, Ailing; Zhang, Yongqing; Liu, Renmin

    2014-10-01

    In this paper, a chromatographic method for isolation and purification of coumarin compounds from Cortex fraxinus was established by using Superose 12 as the separation media for the first time. The conditions for separation were optimized. Four kinds of coumarin compounds including aesuletin, aesculin, fraxetin and fraxin were obtained. The purity of these compounds were 98.5, 99.1, 97.9 and 97.3%, respectively, which were determined by HPLC area normalization method. The chemical structures of the separated compounds were identified according to (1)H and (13)C nuclear magnetic resonance data. The retention behavior of the separated coumarin compounds on Superose 12 was also discussed. The retention is based on a mixture of hydrogen bonding and hydrophobic interactions between the coumarin compounds and the residues of the cross-linking reagents used in the manufacturing process of Superose 12. The results of this paper indicate that Superose 12 is not only suitable for size-exclusion chromatography of proteins and other biological macromolecules but also for low-molecular-weight natural products. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection

    PubMed Central

    Heshka, Nicole E.; Hager, Darcy B.

    2015-01-01

    A method for the analysis of dissolved hydrogen sulfide in crude oil samples is demonstrated using gas chromatography. In order to effectively eliminate interferences, a two dimensional column configuration is used, with a Deans switch employed to transfer hydrogen sulfide from the first to the second column (heart-cutting). Liquid crude samples are first separated on a dimethylpolysiloxane column, and light gases are heart-cut and further separated on a bonded porous layer open tubular (PLOT) column that is able to separate hydrogen sulfide from other light sulfur species. Hydrogen sulfide is then detected with a sulfur chemiluminescence detector, adding an additional layer of selectivity. Following separation and detection of hydrogen sulfide, the system is backflushed to remove the high-boiling hydrocarbons present in the crude samples and to preserve chromatographic integrity. Dissolved hydrogen sulfide has been quantified in liquid samples from 1.1 to 500 ppm, demonstrating wide applicability to a range of samples. The method has also been successfully applied for the analysis of gas samples from crude oil headspace and process gas bags, with measurement from 0.7 to 9,700 ppm hydrogen sulfide. PMID:26709594

  5. Enhancing Analytical Separations Using Super-Resolution Microscopy

    NASA Astrophysics Data System (ADS)

    Moringo, Nicholas A.; Shen, Hao; Bishop, Logan D. C.; Wang, Wenxiao; Landes, Christy F.

    2018-04-01

    Super-resolution microscopy is becoming an invaluable tool to investigate structure and dynamics driving protein interactions at interfaces. In this review, we highlight the applications of super-resolution microscopy for quantifying the physics and chemistry that occur between target proteins and stationary-phase supports during chromatographic separations. Our discussion concentrates on the newfound ability of super-resolved single-protein spectroscopy to inform theoretical parameters via quantification of adsorption-desorption dynamics, protein unfolding, and nanoconfined transport.

  6. Isolation and quantification of oligomeric pyranoanthocyanin-flavanol pigments from red wines by combination of column chromatographic techniques.

    PubMed

    He, Jingren; Santos-Buelga, Celestino; Mateus, Nuno; de Freitas, Victor

    2006-11-17

    A combination of column chromatography on Toyopearl gel HW-40 (S) and polyamide resin has been developed for the preparative isolation and further determination of pyranoanthocyanins of oligomeric nature formed after reaction between anthocyanins and different flavanols in a complex wine matrix. Polyamide chromatography was found to be exceptionally useful to separate oligomeric pyanoanthocyanins from other classes of wine flavonoids and polymerized pigments into an advanced state of purity for further identification and quantification by HPLC-diode array detector coupled with electrospray ionization mass spectrometry (HPLC-DAD/ESI-MS). Fractionation on Toyopearl gel chromatography allowed the separation of pyranoanthocyanins bearing the same flavanols (catechin, epicatechin and procyanidin dimers) but with different anthocyanin moieties (either acylated or non-acylated in the glucose residue) in order to allow further isolation of individual oligomeric pigments on C18 chromatography. A quantitative procedure for analyzing the major pyranoanthocyanin-flavanol derivatives in different aged wines is proposed for the first time. Results obtained showed good reproducibility and recovery regarding sample pretreatment and quantitative method for all analyzed oligomeric pyranoanthocyanins. The combination of these two chromatographic separations is likely to be applicable to the preparative isolation of other anthocyanin-derived pigments.

  7. Two-dimensional preparative liquid chromatography system for preparative separation of minor amount components from complicated natural products.

    PubMed

    Qiu, Ying-Kun; Chen, Fang-Fang; Zhang, Ling-Ling; Yan, Xia; Chen, Lin; Fang, Mei-Juan; Wu, Zhen

    2014-04-11

    An on-line comprehensive two-dimensional preparative liquid chromatography system was developed for preparative separation of minor amount components from complicated natural products. Medium-pressure liquid chromatograph (MPLC) was applied as the first dimension and preparative HPLC as the second one, in conjunction with trapping column and makeup pump. The performance of the trapping column was evaluated, in terms of column size, dilution ratio and diameter-height ratio, as well as system pressure from the view of medium pressure liquid chromatograph. Satisfactory trapping efficiency can be achieved using a commercially available 15 mm × 30 mm i.d. ODS pre-column. The instrument operation and the performance of this MPLC×preparative HPLC system were illustrated by gram-scale isolation of crude macro-porous resin enriched water extract of Rheum hotaoense. Automated multi-step preparative separation of 25 compounds, whose structures were identified by MS, (1)H NMR and even by less-sensitive (13)C NMR, could be achieved in a short period of time using this system, exhibiting great advantages in analytical efficiency and sample treatment capacity compared with conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Solvent viscosity mismatch between the solute plug and the mobile phase: Considerations in the applications of two-dimensional HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shalliker, R. Andrew; Guiochon, Georges A

    Understanding the nature of viscosity contrast induced flow instabilities is an important aspect in the design of two-dimensional HPLC separations. When the viscosity contrast between the sample plug and the mobile phase is sufficiently large, the phenomenon known as viscous fingering can be induced. Viscous fingering is a flow instability phenomenon that occurs at the interface between two fluids with different viscosities. In liquid chromatography, viscous fingering results in the solute band undergoing a change in form as it enters into the chromatography column. Moreover, even in the absence of viscous fingering, band shapes change shape at low viscosity contrasts.more » These changes can result in a noticeable change in separation performance, with the result depending on whether the solvent pushing the solute plug has a higher or lower viscosity than the solute plug. These viscosity induced changes become more important as the solute injection volume increases and hence understanding the process becomes critical in the implementation of multidimensional HPLC techniques, since in these techniques the sample injection plug into the second dimension is an order of magnitude greater than in one-dimensional HPLC. This review article assesses the current understanding of the viscosity contrast induced processes as they relate to liquid chromatographic separation behaviour.« less

  9. Characterization and Determination of Interesterification Markers (Triacylglycerol Regioisomers) in Confectionery Oils by Liquid Chromatography-Mass Spectrometry

    PubMed Central

    Santoro, Valentina; Aigotti, Riccardo; Gastaldi, Daniela; Romaniello, Francesco; Forte, Emanuele; Magni, Martina; Baiocchi, Claudio

    2018-01-01

    Interesterification is an industrial transformation process aiming to change the physico-chemical properties of vegetable oils by redistributing fatty acid position within the original constituent of the triglycerides. In the confectionery industry, controlling formation degree of positional isomers is important in order to obtain fats with the desired properties. Silver ion HPLC (High Performance Liquid Chromatography) is the analytical technique usually adopted to separate triglycerides (TAGs) having different unsaturation degrees. However, separation of TAG positional isomers is a challenge when the number of double bonds is the same and the only difference is in their position within the triglyceride molecule. The TAG positional isomers involved in the present work have a structural specificity that require a separation method tailored to the needs of confectionery industry. The aim of this work was to obtain a chromatographic resolution that might allow reliable qualitative and quantitative evaluation of TAG positional isomers within reasonably rapid retention times and robust in respect of repeatability and reproducibility. The resulting analytical procedure was applied both to confectionery raw materials and final products. PMID:29462917

  10. DETERMINATION OF PERCHLORATE IN SOME FERTILIZERS AND PLANT TISSUE BY RAMAN SPECTROSCOPY

    EPA Science Inventory

    We have successfully used Raman spectroscopy for the direct qualitative and quantitative analysis of perchlorate in fertilizer extracts without the need for chromatographic separation. This approach is attractive because Raman is not hindered by the presence of water or of high ...

  11. HYDROLYSIS OF MTBE IN GROUND WATER SAMPLES PRESERVED WITIH HYDROCHLORIC ACID

    EPA Science Inventory

    Conventional sampling and analytical protocols have poor sensitivity for fuel oxygenates that are alcohols, such as TBA. Because alcohols tend to stay with the water samples, they are not efficiently transferred to the gas chromatograph for separation and analysis. A common tec...

  12. APPLICATION OF A SPRAY DEPOSITION METHOD FOR REVERSED PHASE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

    EPA Science Inventory

    Four coal gasification wastewater samples were analyzed for nonvolatile and polar organics by liquid chromatography-mass spectrometry (LC/MS). Samples were separated on a reverse phase liquid chromatographic column using an aqueous solvent as the eluant. A special spray depositio...

  13. A Gas-Liquid Chromatographic Examination of Stilbene Derivatives

    Treesearch

    Richard W. Hemingway; W. E. Hillis; K Burerton

    1970-01-01

    Trimethylsilyl ether derivatives of twenty hydroxystilbenes were separated by gas-liquid chromatography on Apiezon-L, OV-1, OV-17, and SE-54. Relative retention times were highly dependent upon the degree of hydroxylation and methoxylation, the positions of these groups and on cis-trans...

  14. Liquid chromatographic and ultraviolet spectrophotometric determination of bevantolol and hydrochlorothiazide in feeds.

    PubMed

    Spurlock, C H; Schneider, H G

    1984-01-01

    Separate assay methods have been developed for the 2 components of an 80 + 20 drug blend of bevantolol and hydrochlorothiazide (HCT) in admixtures with animal feed. Drug/diet admixtures are extracted with methanol for reverse phase ion-pair liquid chromatographic (LC) assay of bevantolol, and with acetonitrile for ultraviolet spectrophotometric assay of HCT. Bevantolol, a cardioselective beta blocker, is separated from soluble feed components with an RP-18 column, using methanol-water-acetic acid (60 + 40 + 1) containing 0. 005M octane-sulfonic acid, sodium salt, as ion-pairing reagent. HCT is determined spectrophotometrically in acetonitrile extracts, using a suitable blank extract as reference. Average recovery of HCT from an admixture of 0.5 mg blend/g diet is 94.5% +/- 4.3 RSD and at 2.0 mg/g, 101.5% +/- 3.5 RSD. Bevantolol recovery from the same admixtures is 101.8% +/- 2.7 RSD and 99.0% +/- 3.5 RSD, respectively, using the method as described.

  15. Moment equations for chromatography using superficially porous spherical particles.

    PubMed

    Miyabe, Kanji

    2011-01-01

    New moment equations were developed for chromatography using superficially porous (shell-type) spherical particles, which have recently attracted much attention as one of separation media for fast separation with high efficiency. At first, the moment equations of the first absolute and second central moments in the real time domain were derived from the analytical solution in the Laplace domain of a set of basic equations of the general rate model of chromatography, which represent the mass balance, mass-transfer rate, and reaction kinetics in the column packed with shell-type particles. Then, the moment equations were used for analyzing the experimental data of chromatography of kallidin in a Halo column, which were published in a previous paper written by other researchers. It was tried to predict the chromatographic behavior of shell-type particles having different shell thicknesses. The new moment equations are useful for a detailed analysis of the chromatographic behavior of shell-type spherical particles. It is also concluded that they can be used for the preliminarily optimization of their structural characteristics.

  16. Hydrogen Generator

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Another spinoff from spacecraft fuel cell technology is the portable hydrogen generator shown. Developed by General Electric Company, it is an aid to safer operation of systems that use hydrogen-for example, gas chromatographs, used in laboratory analysis of gases. or flame ionization detectors used as $ollution monitors. The generator eliminates the need for high-pressure hydrogen storage bottles, which can be a safety hazard, in laboratories, hospitals and industrial plants. The unit supplies high-purity hydrogen by means of an electrochemical process which separates the hydrogen and oxygen in distilled water. The oxygen is vented away and the hydrogen gas is stored within the unit for use as needed. GE's Aircraft Equipment Division is producing about 1,000 of the generators annually.

  17. Novel surface modification of polymer-based separation media controlling separation selectivity, retentivity and generation of electroosmotic flow.

    PubMed

    Hosoya, Ken; Kubo, Takuya; Takahashi, Katsuo; Ikegami, Tohru; Tanaka, Nobuo

    2002-12-06

    Uniformly sized packing materials based on synthetic polymer particles for high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) have been prepared from polymerization mixtures containing methacrylic acid (MAA) as a functional monomer and by using a novel surface modification method. This "dispersion method" affords effectively modified separation media. Both the amount of MAA utilized in the preparation and reaction time affect the selectivity of chromatographic separation in both the HPLC and the CEC mode and electroosmotic flow. This detailed study revealed that the dispersion method effectively modified internal surface of macroporous separation media and, based on the amount of MAA introduced, exclusion mechanism for the separation of certain solutes could be observed.

  18. Paper diagnostic for instantaneous blood typing.

    PubMed

    Khan, Mohidus Samad; Thouas, George; Shen, Wei; Whyte, Gordon; Garnier, Gil

    2010-05-15

    Agglutinated blood transports differently onto paper than stable blood with well dispersed red cells. This difference was investigated to develop instantaneous blood typing tests using specific antibody-antigen interactions to trigger blood agglutination. Two series of experiments were performed. The first related the level of agglutination and the fluidic properties of blood on its transport in paper. Blood samples were mixed at different ratios with specific and nonspecific antibodies; a droplet of each mixture was deposited onto a filter paper strip, and the kinetics of wicking and red cell separation were measured. Agglutinated blood phase separated, with the red blood cells (RBC) forming a distinct spot upon contact with paper while the plasma wicked; in contrast, stable blood suspensions wicked uniformly. The second study analyzed the wicking and the chromatographic separation of droplets of blood deposited onto paper strips pretreated with specific and nonspecific antibodies. Drastic differences in transport occurred. Blood agglutinated by interaction with one of its specific antibodies phase separated, causing a chromatographic separation. The red cells wicked very little while the plasma wicked at a faster rate than the original blood sample. Blood agglutination and wicking in paper followed the concepts of colloids chemistry. The immunoglobin M antibodies agglutinated the red blood cells by polymer bridging, upon selective adsorption on the specific antigen at their surface. The transport kinetics was viscosity controlled, with the viscosity of red cells drastically increasing upon blood agglutination. Three arm prototypes were investigated for single-step blood typing.

  19. High-resolution droplet-based fractionation of nano-LC separations onto microarrays for MALDI-MS analysis.

    PubMed

    Küster, Simon K; Pabst, Martin; Jefimovs, Konstantins; Zenobi, Renato; Dittrich, Petra S

    2014-05-20

    We present a robust droplet-based device, which enables the fractionation of ultralow flow rate nanoflow liquid chromatography (nano-LC) eluate streams at high frequencies and high peak resolution. This is achieved by directly interfacing the separation column to a micro T-junction, where the eluate stream is compartmentalized into picoliter droplets. This immediate compartmentalization prevents peak dispersion during eluate transport and conserves the chromatographic performance. Subsequently, nanoliter eluate fractions are collected at a rate of one fraction per second on a high-density microarray to retain the separation with high temporal resolution. Chromatographic separations of up to 45 min runtime can thus be archived on a single microarray possessing 2700 sample spots. The performance of this device is demonstrated by fractionating the separation of a tryptic digest of a known protein mixture onto the microarray chip and subsequently analyzing the sample archive using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Resulting peak widths are found to be significantly reduced compared to standard continuous flow spotting technologies as well as in comparison to a conventional nano-LC-electrospray ionization-mass spectrometry interface. Moreover, we demonstrate the advantage of our high-definition nanofractionation device by applying two different MALDI matrices to all collected fractions in an alternating fashion. Since the information that is obtained from a MALDI-MS measurement depends on the choice of MALDI matrix, we can extract complementary information from neighboring spots containing almost identical composition but different matrices.

  20. [Application of simultaneous determination of inorganic ionic species by advanced ion chromatography for water quality monitoring of river water and wastewater].

    PubMed

    Nakatani, Nobutake; Kozaki, Daisuke; Tanaka, Kazuhiko

    2012-04-01

    In this study, our recent work on advanced ion chromatographic methods for the simultaneous determination of inorganic ionic species such as common anions (SO4(2-), Cl(-) and NO3(-)) and cations (Na+, NH4+, K+, Mg2+, and Ca2+), nutrients (phosphate and silicate) and hydrogen ion/alkalinity are summarized first. Then, the applications using these methods for monitoring environmental water quality are also presented. For the determination of common anions and cations with nutrients, the separation was successfully performed by a polymethacrylate-based weakly acidic cation-exchange column of TSKgel Super IC-A/C (Tosoh, 150 mm x 6.0 mm i. d.) and a mixture solution of 100 mmol/L ascorbic acid and 4 mmol/L 18-crown-6 as acidic eluent with dual detection of conductivity and spectrophotometry. For the determination of hydrogen ion/alkalinity, the separation was conducted by TSKgel ODS-100Z column (Tosoh, 150 mm x 4.5 mm i. d.) modified with lithium dodecylsulfate and an eluent of 40 mmol/L LiCl/0.1 mmol/L lithium dodecylsulfate/0.05 mmol/L H2SO4 with conductivity detector. The differences of ion concentration between untreated and treated wastewater showed the variation of ionic species during biological treatment process in a sewage treatment plant. Occurrence and distribution of water-quality conditions were related to the bioavailability and human activity in watershed. From these results, our advanced ion chromatographic methods have contributed significantly for water quality monitoring of environmental waters.

  1. Role of thin-layer chromatography in ascertaining Kashaya Rasa (astringent taste) in medicinal plants on the concept of Samana and Vichitra Pratyayarabdha principles of Ayurveda

    PubMed Central

    Kolhe, Rasika H.; Acharya, Rabinarayan; Shukla, Vinay J.

    2014-01-01

    Background: Pharmacodynamics, in Ayurveda has been described in terms of Rasadipanchaka. Rasa, on one side indicates the Bhautika composition of the drug and on the other side predicts the action. Different analytical techniques, pharmaceutical processes are being used in Ayurveda for the purpose of standardization of raw drugs. Aim: In this study an attempt has been made to apply chromatographic technique in determination of Kashaya (astringent) Rasa (taste). Materials and Methods: Two important Kashaya dominant drugs Kulattha (Dolichos biflorus Linn.) and Kanchanara (Bauhinia variegata Linn.), falling under Vichitra and Samana Pratyayarabdha category respectively, were subjected to physicochemical parameters and qualitative tests followed by High-Performance Thin-Layer Chromatography (HPTLC). In light of chromatographic fingerprinting; sample preparation protocol is modified to incorporate taste threshold in correlation. Column chromatography is used for first-level discrimination technique followed by HPTLC. Kashaya Rasa Dominant Zone (KsRDZ) was separated and subjected to TLC fingerprinting. The KsRDZ fraction was designated as Botanical Reference Material (BRM) in further analysis. Results: Ash value, Alcohol and water soluble extract value were more in B variegata as compared to D biflorus. Presence of tannin in both the samples was confirmed through qualitative test. The KsRDZ fraction separated at Rf 0.46 and 0.48 for Kulattha and Kanchanara respectively. Conclusion: The results showed that the planner chromatography technique seems very useful when BRM hypothesis was adjunct to method that explains the categorization according to traditional Rasa domain classification method. PMID:25558164

  2. A validated ultra high-pressure liquid chromatography method for separation of candesartan cilexetil impurities and its degradents in drug product

    PubMed Central

    Kumar, Namala Durga Atchuta; Babu, K. Sudhakar; Gosada, Ullas; Sharma, Nitish

    2012-01-01

    Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet formulation. Materials and Methods: The chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with Orthophosphoric acid was used as mobile phase A and 95% acetonitrile with 5% Milli Q Water was used as mobile phase B. Ultraviolet (UV) detection was performed at 254 nm and 210 nm, where (CDS-6), (CDS-5), (CDS-7), (Ethyl Candesartan), (Desethyl CCX), (N-Ethyl), (CCX-1), (1 N Ethyl Oxo CCX), (2 N Ethyl Oxo CCX), (2 N Ethyl) and any unknown impurity were monitored at 254 nm wavelength, and two process-related impurities, trityl alcohol and MTE impurity, were estimated at 210 nm. Candesartan cilexetil andimpurities were chromatographed with a total run time of 20 min. Results: Calibration showed that the response of impurity was a linear function of concentration over the range limit of quantification to 2 μg/mL (r2≥0.999) and the method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, percentage relative standard deviation of each impurity was <15% (n=6). Conclusion: The method was found to be precise, accurate, linear, and specific. The proposed method was successfully employed for estimation of candesartan cilexetil impurities in pharmaceutical preparations. PMID:23781475

  3. Design of simulated moving bed for separation of fumaric acid with a little fronting phenomenon.

    PubMed

    Choi, Jae-Hwan; Kang, Mun-Seok; Lee, Chung-Gi; Wang, Nien-Hwa Linda; Mun, Sungyong

    2017-03-31

    The production of fumaric acid through a biotechnological pathway has grown in importance because of its potential value in related industries. This has sparked an interest in developing an economically-efficient process for separation of fumaric acid (product of interest) from acetic acid (by-product). This study aimed to develop a simulated moving bed (SMB) chromatographic process for such separation in a systematic way. As a first step for this work, commercially available adsorbents were screened for their applicability to the considered separation, which revealed that an Amberchrom-CG71C resin had a sufficient potential to become an adsorbent of the targeted SMB. Using this adsorbent, the intrinsic parameters of fumaric and acetic acids were determined and then applied to optimizing the SMB process under consideration. The optimized SMB process was tested experimentally, from which the yield of fumaric-acid product was found to become lower than expected in the design. An investigation about the reason for such problem revealed that it was attributed to a fronting phenomenon occurring in the solute band of fumaric acid. To resolve this issue, the extent of the fronting was evaluated quantitatively using an experimental axial dispersion coefficient for fumaric acid, which was then considered in the design of the SMB of interest. The SMB experimental results showed that the SMB design based on the consideration of the fumaric-acid fronting could guarantee the attainment of both high purity (>99%) and high yield (>99%) for fumaric-acid product under the desorbent consumption of 2.6 and the throughput of 0.36L/L/h. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Tutorial: simulating chromatography with Microsoft Excel Macros.

    PubMed

    Kadjo, Akinde; Dasgupta, Purnendu K

    2013-04-22

    Chromatography is one of the cornerstones of modern analytical chemistry; developing an instinctive feeling for how chromatography works will be invaluable to future generation of chromatographers. Specialized software programs exist that handle and manipulate chromatographic data; there are also some that simulate chromatograms. However, the algorithm details of such software are not transparent to a beginner. In contrast, how spreadsheet tools like Microsoft Excel™ work is well understood and the software is nearly universally available. We show that the simple repetition of an equilibration process at each plate (a spreadsheet row) followed by discrete movement of the mobile phase down by a row, easily automated by a subroutine (a "Macro" in Excel), readily simulates chromatography. The process is readily understood by a novice. Not only does this permit simulation of isocratic and simple single step gradient elution, linear or multistep gradients are also easily simulated. The versatility of a transparent and easily understandable computational platform further enables the simulation of complex but commonly encountered chromatographic scenarios such as the effects of nonlinear isotherms, active sites, column overloading, on-column analyte degradation, etc. These are not as easily simulated by available software. Views of the separation as it develops on the column and as it is seen by an end-column detector are both available in real time. Excel 2010™ also permits a 16-level (4-bit) color gradation of numerical values in a column/row; this permits visualization of a band migrating down the column, much as Tswett may have originally observed, but in a numerical domain. All parameters of relevance (partition constants, elution conditions, etc.) are readily changed so their effects can be examined. Illustrative Excel spreadsheets are given in the Supporting Information; these are easily modified by the user or the user can write his/her own routine. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. GlyQ-IQ: Glycomics Quintavariate-Informed Quantification with High-Performance Computing and GlycoGrid 4D Visualization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kronewitter, Scott R.; Slysz, Gordon W.; Marginean, Ioan

    2014-05-31

    Dense LC-MS datasets have convoluted extracted ion chromatograms with multiple chromatographic peaks that cloud the differentiation between intact compounds with their overlapping isotopic distributions, peaks due to insource ion fragmentation, and noise. Making this differentiation is critical in glycomics datasets because chromatographic peaks correspond to different intact glycan structural isomers. The GlyQ-IQ software is targeted chromatography centric software designed for chromatogram and mass spectra data processing and subsequent glycan composition annotation. The targeted analysis approach offers several key advantages to LC-MS data processing and annotation over traditional algorithms. A priori information about the individual target’s elemental composition allows for exactmore » isotope profile modeling for improved feature detection and increased sensitivity by focusing chromatogram generation and peak fitting on the isotopic species in the distribution having the highest intensity and data quality. Glycan target annotation is corroborated by glycan family relationships and in source fragmentation detection. The GlyQ-IQ software is developed in this work (Part 1) and was used to profile N-glycan compositions from human serum LC-MS Datasets. The companion manuscript GlyQ-IQ Part 2 discusses developments in human serum N-glycan sample preparation, glycan isomer separation, and glycan electrospray ionization. A case study is presented to demonstrate how GlyQ-IQ identifies and removes confounding chromatographic peaks from high mannose glycan isomers from human blood serum. In addition, GlyQ-IQ was used to generate a broad N-glycan profile from a high resolution (100K/60K) nESI-LS-MS/MS dataset including CID and HCD fragmentation acquired on a Velos Pro Mass spectrometer. 101 glycan compositions and 353 isomer peaks were detected from a single sample. 99% of the GlyQ-IQ glycan-feature assignments passed manual validation and are backed with high resolution mass spectra and mass accuracies less than 7 ppm.« less

  6. Development of a perfusion reversed-phase high performance liquid chromatography method for the characterisation of maize products using multivariate analysis.

    PubMed

    Rodriguez-Nogales, J M; Garcia, M C; Marina, M L

    2006-02-03

    A perfusion reversed-phase high performance liquid chromatography (RP-HPLC) method has been designed to allow rapid (3.4 min) separations of maize proteins with high resolution. Several factors, such as extraction conditions, temperature, detection wavelength and type and concentration of ion-pairing agent were optimised. A fine optimisation of the gradient elution was also performed by applying experimental design. Commercial maize products for human consumption (flours, precocked flours, fried snacks and extruded snacks) were characterised for the first time by perfusion RP-HPLC and their chromatographic profiles allowed a differentiation among products relating the different technological process used for their preparation. Furthermore, applying discriminant analysis makes it possible to group the samples according with the technological process suffered by maize products, obtaining a good prediction in 92% of the samples.

  7. Sampling of atmospheric carbonyl compounds for determination by liquid chromatography after 2,4-dinitrophenylhydrazine labelling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vairavamurthy, A.; Roberts, J.M.; Newman, L.

    1991-06-01

    Carbonyl compounds are both primary (directly emitted) and secondary (formed in situ) atmospheric species, which play a major role in tropospheric photochemistry. Because of trace concentrations (parts-per-billion and lower), ambient air measurements of carbonyls pose serious analytical problems. Generally, chromatographic approaches combined with chemical derivatization have been used to enhance sensitivity and selectivity in analysis. Currently, the liquid chromatographic method coupled to 2,4-dinitrophenylhydrazine derivatization (DNPH-LC) is in widespread use. Interferences arising from similar compounds are greatly minimized by chromatographic separation; however, those in the air sampling step, especially with ozone, continue to be problematic and remain to be resolved. Wemore » discuss here the different sampling techniques used for time-integrated collection of carbonyls in the DNPH-LC methods. Emphasis is placed on addressing: (1) the principles, advantages, and limitations of sampling techniques; (2) problems associated with reagent blank and sampling instrument; and (3) effects of atmospheric co-pollutants, especially ozone. 58 refs., 8 figs., 3 tabs.« less

  8. Solvent-modified solid-phase microextraction for the determination of diazepam in human plasma samples by capillary gas chromatography.

    PubMed

    Krogh, M; Grefslie, H; Rasmussen, K E

    1997-02-21

    This paper describes microextraction and gas chromatographic analysis of diazepam from human plasma. The method was based on immobilisation of 1.5 microliters of 1-octanol on a polyacrylate-coated fiber designed for solid-phase microextraction. The solvent-modified fibre was used to extract diazepam from the samples. The plasma sample was pre-treated to release diazepam from the protein binding. The fibre was inserted into the modified plasma sample, adjusted to pH 5.5 an internal standard was added and the mixture was carefully stirred for 4 min. The fibre with the immobilised solvent and the enriched analytes was injected into the capillary gas chromatograph. The solvent and the extracted analytes were evaporated at 300 degrees C in the split-splitless injection port of the gas chromatograph, separated on a methylsilicon capillary column and detected with a nitrogen-phosphorus detector. The method was shown to be reproducible with a detection limit of 0.10 nmol/ml in human plasma.

  9. RAMAN SPECTROSCOPIC ANALYSIS OF FERTILIZERS AND PLANT TISSUE FOR PERCHLORATE

    EPA Science Inventory

    Raman spectroscopy, without the need for prior chromatographic separation, was used for qualitative and quantitative analysis of 59 samples of fertilizers for perchlorate (ClO4-). These primarily lawn and garden products had no known link to Chile saltpeter, which is known to con...

  10. RAMAN SPECTROSCOPIC ANALYSIS OF FERTILIZERS AND C FOR PERCHLORATE-JOURNAL ARTICLE

    EPA Science Inventory

    Raman spectroscopy, without the need for prior chromatographic separation, was used for qualitative and quantitative analysis of 59 samples of fertilizers for perchlorate (ClO4-). These primarily lawn and garden products had no known link to Chile saltpeter, which is known to con...

  11. Flavonoid content and antioxidant capacity of spinach genotypes determined by high-performance liquid chromatography/mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    Flavonoids in different spinach genotypes were separated, identified, and quantified by a high-performance liquid chromatographic method with photodiode array and mass spectrometric detection. The antioxidant capacities of the genotypes were also measured using two antioxidant assays - oxygen radica...

  12. Microfabricated capillary electrophoresis chip and method for simultaneously detecting multiple redox labels

    DOEpatents

    Mathies, Richard A.; Singhal, Pankaj; Xie, Jin; Glazer, Alexander N.

    2002-01-01

    This invention relates to a microfabricated capillary electrophoresis chip for detecting multiple redox-active labels simultaneously using a matrix coding scheme and to a method of selectively labeling analytes for simultaneous electrochemical detection of multiple label-analyte conjugates after electrophoretic or chromatographic separation.

  13. Simulated countercurrent moving bed chromatographic reactor and method for use thereof

    DOEpatents

    Carr, Robert W.; Tonkovich, Anna Lee Y.

    2001-01-01

    A method and apparatus for continuously reacting a feed gas to form a product and separating the product from unreacted feed gas is provided. The apparatus includes a plurality of compartments and means for connecting the compartments in a series, with the last compartment in the series being connected to the first compartment in the series to provide a closed loop. Each compartment may include an upstream reaction zone and a downstream separation zone.

  14. Less common applications of simulated moving bed chromatography in the pharmaceutical industry.

    PubMed

    Huthmann, E; Juza, M

    2005-10-21

    Simulated moving bed (SMB) chromatography is often perceived in the pharmaceutical industry as chromatographic method for separating binary mixtures, like racemates. However, SMB can also be used for unbalanced separations, i.e. binary mixtures of varying compositions and multi-component mixtures. These less common application modes of isocratic SMB chromatography are exemplified for four different compounds (racemates and diastereomers) and discussed in view of the so-called 'triangle theory' from an industrial perspective.

  15. High-aspect-ratio, silicon oxide-enclosed pillar structures in microfluidic liquid chromatography.

    PubMed

    Taylor, Lisa C; Lavrik, Nickolay V; Sepaniak, Michael J

    2010-11-15

    The present paper discusses the ability to separate chemical species using high-aspect-ratio, silicon oxide-enclosed pillar arrays. These miniaturized chromatographic systems require smaller sample volumes, experience less flow resistance, and generate superior separation efficiency over traditional packed bed liquid chromatographic columns, improvements controlled by the increased order and decreased pore size of the systems. In our distinctive fabrication sequence, plasma-enhanced chemical vapor deposition (PECVD) of silicon oxide is used to alter the surface and structural properties of the pillars for facile surface modification while improving the pillar mechanical stability and increasing surface area. The separation behavior of model compounds within our pillar systems indicated an unexpected hydrophobic-like separation mechanism. The effects of organic modifier, ionic concentration, and pressure-driven flow rate were studied. A decrease in the organic content of the mobile phase increased peak resolution while detrimentally effecting peak shape. A resolution of 4.7 (RSD = 3.7%) was obtained for nearly perfect Gaussian shaped peaks, exhibiting plate heights as low as 1.1 and 1.8 μm for fluorescein and sulforhodamine B, respectively. Contact angle measurements and DART mass spectrometry analysis indicate that our employed elastomeric soft bonding technique modifies pillar properties, creating a fortuitous stationary phase. This discovery provides evidence supporting the ability to easily functionalize PECVD oxide surfaces by gas-phase reactions.

  16. Simultaneous determination of azathioprine and 6-mercaptopurine by high-performance liquid chromatography.

    PubMed

    Van Os, E C; McKinney, J A; Zins, B J; Mays, D C; Schriver, Z H; Sandborn, W J; Lipsky, J J

    1996-04-26

    A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2-200 ng/ml. No chromatographic interferences were detected.

  17. Novel devices for solvent delivery and temperature programming designed for capillary liquid chromatography.

    PubMed

    Coutinho, Lincoln Figueira Marins; Nazario, Carlos Eduardo Domingues; Monteiro, Alessandra Maffei; Lanças, Fernando Mauro

    2014-08-01

    Analyses in chromatographic systems able to save mobile and stationary phases without reducing efficiency and resolution are of current interest. These advantages regarding savings have challenged us to develop a system dedicated to miniaturized liquid chromatography. This paper reports on the development of a high-pressure syringe-type pump, an oven able to perform isothermal and temperature programming and a software program to control these chromatographic devices. The experimental results show that the miniaturized system can generate reproducible and accurate temperature and flow rate. The system was applied to the separation of statins and tetracylines and showed excellent performance. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Characterization of a chemical artifact in the liquid chromatographic determination of 3-butyn-2-one using the 2,4-dinitrophenylhydrazine method.

    PubMed

    Vogel, M; Pötter, W; Karst, U

    2000-07-21

    This study reports the identification of a chemical artifact occurring in the liquid chromatographic analysis of 3-butyn-2-one by means of the 2,4-dinitrophenylhydrazine (DNPH) method. Besides the expected derivatization reaction to the corresponding butynone DNPhydrazone, a rearrangement was observed, thus leading to the formation of 3-methyl-1-(2',4'-dinitrophenyl)pyrazol (DNPP). Although the rearrangement product and the hydrazone can easily be separated by means of liquid chromatography, problems arise from coelution of the pyrazol with the formaldehyde DNPhydrazone. Identification of the artifact by means of UV-Vis spectroscopy using dual wavelength or diode array detection is discussed.

  19. Rapid thin-layer chromatographic photodensitometric method for the determination of metoclopramide and clebopride in the presence of some of their metabolic products.

    PubMed

    Huizing, G; Beckett, A H; Segura, J

    1979-04-21

    Metoclopramide and its newly developed analogue clebopride, together with some of their metabolic products are quantitated, following extraction from biological tissues and fluids, and subsequent separation on silica gel thin-layer chromatographic plates. Diazotisation, followed by coupling with N-(1-naphthyl)ethylenediammonium dichloride, carried out on the thin-layer plate, is utilised for visualisation. The intensity of the spots is measured by photodensitometric analysis. The effect of variation of various experimental conditions is studied. The method has proven to be satisfactory for the measurement of 20 ng/ml of these compounds in biological material; the results are well within the accepted limits of deviation.

  20. Variables affecting resolution of lung phospholipids in one-dimensional thin-layer chromatography.

    PubMed

    Krahn, J

    1987-01-01

    Resolution of the confusion in the literature about the separation of lung phospholipids in thin-layer chromatographic systems has awaited a systematic study of the variables that potentially affect this separation. In this study I show that: incorporation of ammonium sulfate into silica gel "GHL" has a dramatic effect on separation of lung phospholipids; this effect is equally dramatic but different in activated and nonactivated gels; when it picks up moisture, ammonium sulfate-activated gel very rapidly loses its ability to resolve lecithin from phosphatidylinositol; in gel containing ammonium sulfate, small amounts of phosphatidylethanolamine are hydrolyzed to lyso-phosphatidylethanolamine.

  1. Supercritical fluid technology: a promising approach in pharmaceutical research.

    PubMed

    Girotra, Priti; Singh, Shailendra Kumar; Nagpal, Kalpana

    2013-02-01

    Supercritical fluids possess the unique properties of behaving like liquids and gases, above their critical point. Supercritical fluid technology has recently emerged as a green and novel technique for various processes such as solubility enhancement of poorly soluble drugs, plasticization of polymers, surface modification, nanosizing and nanocrystal modification, and chromatographic extraction. Research interest in this area has been fuelled because of the numerous advantages that the technology offers over the conventional methods. This work aims to review the merits, demerits, and various processes such as rapid expansion of supercritical solutions (RESS), particles from gas saturated solutions (PGSS), gas antisolvent process (GAS), supercritical antisolvent process (SAS) and polymerization induced phase separation (PIPS), that have enabled this technology to considerably raise the interest of researchers over the past two decades. An insight has been given into the numerous applications of this technology in pharmaceutical industry and the future challenges which must be appropriately dealt with to make it effective on a commercial scale.

  2. Evaluation of a liquid chromatography method for compound-specific δ13C analysis of plant carbohydrates in alkaline media.

    PubMed

    Rinne, Katja T; Saurer, Matthias; Streit, Kathrin; Siegwolf, Rolf T W

    2012-09-30

    Isotope analysis of carbohydrates is important for improved understanding of plant carbon metabolism and plant physiological response to the environment. High-performance liquid chromatography/isotope ratio mass spectrometry (HPLC/IRMS) for direct compound-specific δ(13)C measurements of soluble carbohydrates has recently been developed, but the still challenging sample preparation and the fact that no single method is capable of separating all compounds of interest hinder its wide-spread application. Here we tested in detail a chromatography method in alkaline media. We examined the most suitable chromatographic conditions for HPLC/IRMS analysis of carbohydrates in aqueous conifer needle extracts using a CarboPac PA20 anion-exchange column with NaOH eluent, paying specific attention to compound yields, carbon isotope fractionation processes and the reproducibility of the method. Furthermore, we adapted and calibrated sample preparation methods for HPLC/IRMS analysis. OnGuard II cartridges were used for sample purification. Good peak separation and highly linear and reproducible concentration and δ(13)C measurements were obtained. The alkaline eluent was observed to induce isomerization of hexoses, detected as reduced yields and (13)C fractionation of the affected compounds. A reproducible pre-purification method providing ~100% yield for the carbohydrate compounds of interest was calibrated. The good level of peak separation obtained in this study is reflected in the good precision and linearity of concentration and δ(13)C results. The data provided crucial information on the behaviour of sugars in LC analysis with alkaline media. The observations highlight the importance for the application of compound-matched standard solution for the detection and correction of instrumental biases in concentration and δ(13)C analysis performed under identical chromatographic conditions. The calibrated pre-purification method is well suited for studies with complex matrices that disable the use of a spiked internal standard for the detection of procedural losses. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Effects of urea induced protein conformational changes on ion exchange chromatographic behavior.

    PubMed

    Hou, Ying; Hansen, Thomas B; Staby, Arne; Cramer, Steven M

    2010-11-19

    Urea is widely employed to facilitate protein separations in ion exchange chromatography at various scales. In this work, five model proteins were used to examine the chromatographic effects of protein conformational changes induced by urea in ion exchange chromatography. Linear gradient experiments were carried out at various urea concentrations and the protein secondary and tertiary structures were evaluated by far UV CD and fluorescence measurements, respectively. The results indicated that chromatographic retention times were well correlated with structural changes and that they were more sensitive to tertiary structural change. Steric Mass Action (SMA) isotherm parameters were also examined and the results indicated that urea induced protein conformational changes could affect both the characteristic charge and equilibrium constants in these systems. Dynamic light scattering analysis of changes in protein size due to urea-induced unfolding indicated that the size of the protein was not correlated with SMA parameter changes. These results indicate that while urea-induced structural changes can have a marked effect on protein chromatographic behavior in IEX, this behavior can be quite complicated and protein specific. These differences in protein behavior may provide insight into how these partially unfolded proteins are interacting with the resin material. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. [HPLC fingerprint of flavonoids in Sophora flavescens and determination of five components].

    PubMed

    Ma, Hong-Yan; Zhou, Wan-Shan; Chu, Fu-Jiang; Wang, Dong; Liang, Sheng-Wang; Li, Shao

    2013-08-01

    A simple and reliable method of high-performance liquid chromatography with photodiode array detection (HPLC-DAD) was developed to evaluate the quality of a traditional Chinese medicine Sophora flavescens through establishing chromatographic fingerprint and simultaneous determination of five flavonoids, including trifolirhizin, maackiain, kushenol I, kurarinone and sophoraflavanone G. The optimal conditions of separation and detection were achieved on an ULTIMATE XB-C18 column (4.6 mm x 250 mm, 5 microm) with a gradient of acetonitrile and water, detected at 295 nm. In the chromatographic fingerprint, 13 peaks were selected as the characteristic peaks to assess the similarities of different samples collected from different origins in China according to similarity evaluation for chromatographic fingerprint of traditional chinese medicine (2004AB) and principal component analysis (PCA) were used in data analysis. There were significant differences in the fingerprint chromatograms between S. flavescens and S. tonkinensis. Principal component analysis showed that kurarinone and sophoraflavanone G were the most important component. In quantitative analysis, the five components showed good regression (R > 0.999) with linear ranges, and their recoveries were in the range of 96.3% - 102.3%. This study indicated that the combination of quantitative and chromatographic fingerprint analysis can be readily utilized as a quality control method for S. flavescens and its related traditional Chinese medicinal preparations.

  5. Monolithic columns with organic sorbent based on poly-1-vinylimidazole for high performance liquid chromatography

    NASA Astrophysics Data System (ADS)

    Patrushev, Y. V.; Sidelnikov, V. N.; Yudina, Y. S.

    2017-03-01

    Monolithic chromatographic columns for HPLC with sorbent based on 1-vinylimidazole are prepared. It is shown that changing the 1-vinylimidazole content in the initial solution allows us to change the polarity of columns. An example of aromatic hydrocarbons separation is presented.

  6. EXTRACTION AND DETECTION OF ARSENICALS IN SEAWEED VIA ACCELERATED SOLVENT EXTRACTION WITH ION CHROMATOGRAPHIC SEPARATION AND ICP-MS DETECTION

    EPA Science Inventory

    An accelerated solvent extraction (ASE) device was evaluated as a semi-automated means of extracting arsenicals from ribbon kelp. Objective was to investigate effect of experimentally controllable ASE parameters (pressure, temperature, static time and solvent composition) on extr...

  7. CHROMATOGRAPHIC SEPARATION AND IDENTIFICATION OF PRODUCTS FROM THE REACTION OF DIMETHYLARSINIC ACID WITH HYDROGEN SULFIDE

    EPA Science Inventory

    The reaction of dimethylarsinic acid (DMAV) with hydrogen sulfide (H2S) is of biological significance and may be implicated in the overall toxicity and carcinogenicity of arsenic. The course of the reaction in aqueous phase was monitored and an initial product, dimethylthioarsin...

  8. Evaluation of rotating-cylinder and piston-cylinder reactors for ground-based emulsion polymerization

    NASA Technical Reports Server (NTRS)

    Vanderhoff, J. W.; El-Aasser, M. S.

    1987-01-01

    The objectives of this program are to apply ground-based emulsion polymerization reactor technology to improve the production of: monodisperse latex particles for calibration standards, chromatographic separation column packing, and medical research; and commercial latexes such as those used for coatings, foams, and adhesives.

  9. Peptidoglycan precursor from Fusobacterium nucleatum contains lanthionine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fredriksen, A.; Vasstrand, E.N.; Jensen, H.B.

    1991-01-01

    Fusobacterium nucleatum was grown in the presence of ({sup 14}C)UDP. By means of sequential precipitation and chromatographic separation of the cytoplasmic content, a peptidoglycan ({sup 14}C)UDP pentapeptide containing lanthionine was isolated. This finding indicates that lanthionine is synthesized and incorporated as such during the assembly of the peptidoglycan.

  10. Determination of Arsenical Herbicide Residues in Plant Tissues

    Treesearch

    R.M. Sachs; J.L. Michael; F.B. Anastasia; W.A. Wells

    1971-01-01

    Paper chromatographic separation of hydroxydimethylarsine oxide (cacodylic acid), monosodium methanearsonate (MSMA), sodium arsenate, and sodium arsenite was achieved with the aid of four solvent systems. Aqueous extracts of plant tissues removed essentially all the arscnicals applied, but mechanoiic fractionation was required before the extracts could be analyzed by...

  11. ION COMPOSITION ELUCIDATION (ICE): A HIGH RESOLUTION MASS SPECTROMETRIC TOOL FOR IDENTIFYING ORGANIC COMPOUNDS IN COMPLEX EXTRACTS OF ENVIRONMENTAL SAMPLES

    EPA Science Inventory


    Unidentified Organic Compounds. For target analytes, standards are purchased, extraction and clean-up procedures are optimized, and mass spectra and retention times for the chromatographic separation are obtained for comparison to the target compounds in environmental sample ...

  12. NOVEL CHROMATOGRAPHIC SEPARATION AND CARBON SOLID PHASE EXTRACTION OF ACETANILIDE HERBICIDE DEGRADATION PRODUCTS

    EPA Science Inventory

    Six acetanilide herbicides are currently registered for use in the U.S. Over the past several years, ethanesufonic acid (ESA) and oxanilic acid (OA) degradatoin products of these acetanilide herbicides have been found in U.S. ground waters and surface waters. "Alachlor ESA and ...

  13. Simultaneous separation and purification of flavonoids and oleuropein from Olea europaea L. (olive) leaves using macroporous resin.

    PubMed

    Li, Chen; Zheng, Yuanyuan; Wang, Xiaofei; Feng, Shilan; Di, Duolong

    2011-12-01

    This study developed a feasible process to simultaneously separate and purify polyphenols, including flavonoids and oleuropein, from the leaves of Olea europaea L. Macroporous resins were used as the separation and purification materials. The performance and separation capabilities of eight resins (D101, DM130, HPD450, LSA-21, LSA-40, 07C, LSD001 and HPD600) were systematically evaluated. The contents of target polyphenols in different extracts were determined using ultraviolet (for flavonoids) and high-performance liquid chromatographic (for oleuropein) methods. The static adsorption and desorption results showed that resin LSA-21 had better adsorption properties among the eight resins. Influential factors such as extraction method, pH value of feeding solution, desorption solution, adsorption kinetics and adsorption isotherm, etc. to the extraction and purification of these polyphenols were successively investigated on resin LSA-21. The target flavonoids and oleuropein were selectively purified using resin LSA-21. Compared with the contents in raw leaves, the contents of total flavonoids and oleuropein in the final purified products were increased 13.2-fold (from 16 to 211 g kg(-1) ) and 7.5-fold (from 120 to 902 g kg(-1) ) with recovery yields of 87.9% and 85.6%, respectively. This extraction and purification method could be used in the large-scale enrichment or purification of flavonoids, oleuropein and other polyphenols from O. europaea L. leaves or other herbal materials in industrial, food processing and medical manufacture. Copyright © 2011 Society of Chemical Industry.

  14. A validated chiral liquid chromatographic method for the enantiomeric separation of safinamide mesilate, a new anti-Parkinson drug.

    PubMed

    Zhang, Kai; Xue, Na; Shi, Xiaowei; Liu, Weina; Meng, Jing; Du, Yumin

    2011-04-28

    A enantioselective reversed-phase high performance liquid chromatographic method was developed for the enantiomeric resolution of safinamide mesilate, 2(S)-[4-(3-fluorobenzyloxy)benzylamino] propionamide methanesulfonate, a neuroprotectant with antiparkinsonian and anticonvulsant activity for the treatment of Parkinson disease. The enantiomers of safinamide mesilate were baseline resolved on a Chiralcel OD-RH (150mm×4.6mm, 5μm) column using a mobile phase system containing 300mM sodium di-hydrogen phosphate buffer (pH 3.0):methanol:acetonitrile (65:25:10, v/v/v). The resolution between the enantiomers was not less than 3.0. The pH value of buffer solution in the mobile phase has played a key role in enhancing chromatographic efficiency and resolution between the enantiomers. The developed method was validated and proved to be robust. The limit of detection and limit of quantification of (R)-enantiomer were found to be 15 and 50ng/mL, respectively, for 20μL injection volume. The percentage recovery of (R)-enantiomer was ranged from 94.2 to 103.7 in bulk drug samples of safinamide mesilate. The sample solution and mobile phase were found to be stable at least for 48h. The final optimized method was successfully applied to separate (R)-enantiomer from safinamide mesilate and was proven to be reproducible and accurate for the quantitative determination of (R)-enantiomer in bulk drugs. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Different Spectrophotometric and Chromatographic Methods for Determination of Mepivacaine and Its Toxic Impurity.

    PubMed

    Abdelwahab, Nada S; Fared, Nehal F; Elagawany, Mohamed; Abdelmomen, Esraa H

    2017-09-01

    Stability-indicating spectrophotometric, TLC-densitometric, and ultra-performance LC (UPLC) methods were developed for the determination of mepivacaine HCl (MEP) in the presence of its toxic impurity, 2,6-dimethylanaline (DMA). Different spectrophotometric methods were developed for the determination of MEP and DMA. In a dual-wavelength method combined with direct spectrophotometric measurement, the absorbance difference between 221.4 and 240 nm was used for MEP measurements, whereas the absorbance at 283 nm was used for measuring DMA in the binary mixture. In the second-derivative method, amplitudes at 272.2 and 232.6 nm were recorded and used for the determination of MEP and DMA, respectively. The developed TLC-densitometric method depended on chromatographic separation using silica gel 60 F254 TLC plates as a stationary phase and methanol-water-acetic acid (9 + 1 + 0.1, v/v/v) as a developing system, with UV scanning at 230 nm. The developed UPLC method depended on separation using a C18 column (250 × 4.6 mm id, 5 μm particle size) as a stationary phase and acetonitrile-water (40 + 60, v/v; pH 4 with phosphoric acid) as a mobile phase at a flow rate of 0.4 mL/min, with UV detection at 215 nm. The chromatographic run time was approximately 1 min. The proposed methods were validated with respect to International Conference on Harmonization guidelines regarding precision, accuracy, ruggedness, robustness, and specificity.

  16. A versatile liquid chromatographic technique for pharmacokinetic estimation of curcumin in human plasma.

    PubMed

    Gugulothu, Dalapathi; Desai, Preshita; Patravale, Vandana

    2014-09-01

    A simple, rapid, sensitive and specific liquid chromatographic method was developed and validated for the determination of curcumin in human plasma. Berberine was used as the internal standard. Chromatographic separation was achieved on a Zorbax Eclipse C18 column at 40 °C, with a mobile phase consisting of 1% acetic acid (pH 3 adjusted with 50% triethanolamine): acetonitrile (55:45), at a flow rate of 1.25 mL/min. The method was validated for precision, accuracy, linearity, lower limit of quantification (LLOQ) and extraction efficiency according to the International Conference on Harmonization guidelines. The method was successfully developed with an LLOQ of 10 ng/mL and a runtime of 9 min. Linearity range was from 10 to 1000 ng/mL. Curcumin and Berberine were well separated with retention times of 8.2 ± 0.2 and 1.4 ± 0.1 min, respectively. Further, the method was successfully employed to study the pharmacokinetic parameters of curcumin, following oral administration of curcumin-loaded hydroxy propyl cellulose (HPC) nanoparticles and curcumin suspension in female Wistar rats. Curcumin-loaded HPC nanoparticles (Cmax: 106.01 ± 20.11 ng/mL) showed significant improvement in pharmacokinetic parameters when compared with curcumin suspension (Cmax: 30.13 ± 0.47 ng/mL) indicating 43.73-fold increase in relative bioavailability. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. A simple subcritical chromatographic test for an extended ODS high performance liquid chromatography column classification.

    PubMed

    Lesellier, Eric; Tchapla, Alain

    2005-12-23

    This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.

  18. Development and validation of a high performance liquid chromatographic method for the separation of exo and endo isomers of granatamine (9-methyl-9-azabicyclo[3.3.1]nonan-3-amine); a key intermediate of granisetron.

    PubMed

    Krishna, S Radha; Babu, P Suresh; Rao, B M; Rao, N Someswara

    2009-12-01

    A simple and accurate high-performance liquid chromatographic method was developed for the determination of exo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine in endo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine, commercially known as grantamine and used as a key intermediate in the preparation of granisetron bulk drug. Chromatographic separation of the exo and endo isomers of 9-methyl-9-azabicyclo[3.3.1]nonan-3-amine was achieved on an Inertsil C8 column using a mobile phase containing 0.3% trifluoroacetic acid. The resolution between the two isomers was found to be more than 4. The limit of detection (LOD) and limit of quantification (LOQ) of exo isomer were 0.8 and 2.5 microg x mL(-1) respectively, for a 10 microL injection volume. The percentage recovery of exo-isomer ranged from 99 to 102% w/w in the endo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine sample. The test solution and mobile phase were observed to be stable up to 48 h after preparation. The validated method yielded good results for precision, linearity, accuracy, robustness and ruggedness. The proposed method was found to be suitable and accurate for the quantitative determination of exo-isomer in bulk samples of endo-9-methyl-9-azabicyclo[3.3.1]nonan-3-amine.

  19. Chemically Layered Porous Solids

    NASA Technical Reports Server (NTRS)

    Koontz, Steve

    1991-01-01

    Aerogels and other porous solids in which surfaces of pores have chemical properties varying with depth below macroscopic surfaces prepared by sequences of chemical treatments. Porous glass or silica bead treated to make two depth zones having different chemical properties. Beads dropped along tube filled with flowing gas containing atomic oxygen, generated in microwave discharge. General class of materials treatable include oxides of aluminum, silicon, zirconium, tin, titanium, and nickel, and mixtures of these oxides. Potential uses of treated materials include chromatographic separations, membrane separations, controlled releases of chemicals, and catalysis.

  20. Activation analysis of admixtures in certain semiconductive materials

    NASA Technical Reports Server (NTRS)

    Artyukhin, P. I.; Gilbert, E. P.; Pronin, V. A.

    1978-01-01

    The use of extractions and chromatographic operations to separate macrobases, and to divide elements into groups convenient for gamma-spectrometric analysis is discussed. Methods are described for the activation detection of some impurities in silicon, arsenic, thallium, and trichloromethylsilane, on the basis of the extraction properties of bis(2-chlorethyl ether) and dimethylbenzylalkylammonium chloride. A schematic diagram of the extraction separation of elements-admixture is presented showing the aqueous and organic phases. The content percentage of the various elements are given in tables.

  1. A narrow open tubular column for high efficiency liquid chromatographic separation.

    PubMed

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen; Xiang, Piliang; Ren, Jiangtao; Meng, Yunzhu; Zhang, Kaiqi; Juan Lu, Joann; Liu, Shaorong

    2018-04-30

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow (e.g., 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar. The column is coated with octadecylsilane and both isocratic and gradient separations are performed. We reveal a focusing effect that may be used to interpret the efficiency enhancement. We also demonstrate the feasibility of using this technique for separating complex peptide samples. This high-resolution and fast separation technique is promising and can lead to a powerful tool for trace sample analysis.

  2. Measurement of plutonium isotope ratios in nuclear fuel samples by HPLC-MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Günther-Leopold, I.; Waldis, J. Kobler; Wernli, B.; Kopajtic, Z.

    2005-04-01

    Radioactive isotopes are traditionally quantified by means of radioactivity counting techniques ([alpha], [beta], [gamma]). However, these methods often require extensive matrix separation and sample purification before the identification of specific isotopes and their relative abundance is possible as it is necessary in the frame of post-irradiation examinations on nuclear fuel samples. The technique of multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is attracting much attention because it permits the precise measurement of the isotope compositions for a wide range of elements combined with excellent limits of detection due to high ionization efficiencies. The present paper describes one of the first applications of an online high-performance liquid chromatographic separation system coupled to a MC-ICP-MS in order to overcome isobaric interferences for the determination of the plutonium isotope composition and concentrations in irradiated nuclear fuels. The described chromatographic separation is sufficient to prevent any isobaric interference between 238Pu present at trace concentrations and 238U present as the main component of the fuel samples. The external reproducibility of the uncorrected plutonium isotope ratios was determined to be between 0.04 and 0.2% (2 s) resulting in a precision in the [per mille sign] range for the isotopic vectors of the irradiated fuel samples.

  3. Characterization of selenium species in biological extracts by enhanced ion-pair liquid chromatography with inductively coupled plasma-mass spectrometry and by referenced electrospray ionization-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Kotrebai, Mihály; Bird, Susan M.; Tyson, Julian F.; Block, Eric; Uden, Peter C.

    1999-11-01

    Selenium is an essential nutrient for humans; selenium compounds catalyze intermediate metabolism reactions and inhibit the toxic effects of heavy metals such as arsenic, cadmium and mercury. Some extracts of selenium-enriched biological materials show cancer preventive effects, tentatively attributable to the biological functions of selenoamino acids. An improved ion pair chromatographic method with methodological enhancements for the separation, qualitative and quantitative determination of non-volatile selenium compounds extracted from different samples has been developed using ICP-MS as an element-selective detector. Separation power early in the chromatogram was increased to baseline separation in the standard mixture as a result of decreasing spray chamber size from 97 to 14 ml, and increasing trifluoracetic acid (TFA) concentration in the mobile phase from 0.1 to 0.6%. The former pH was restored by the addition of ammonia to the mobile phase, which also served to increase the column recovery of inorganic anions. Calibration curves for different selenoamino acids showed statistically different behavior. Biological sample extracts were characterized using HPLC-ICP-MS. Mass spectral behavior of selenoamino acids, using electrospray and ion trap technology with direct infusion and liquid chromatographic sample introduction, is also reported.

  4. Fiber-based monolithic columns for liquid chromatography.

    PubMed

    Ladisch, Michael; Zhang, Leyu

    2016-10-01

    Fiber-based monoliths for use in liquid chromatographic separations are defined by columns packed with aligned fibers, woven matrices, or contiguous fiber structures capable of achieving rapid separations of proteins, macromolecules, and low molecular weight components. A common denominator and motivating driver for this approach, first initiated 25 years ago, was reducing the cost of bioseparations in a manner that also reduced residence time of retained components while achieving a high ratio of mass to momentum transfer. This type of medium, when packed into a liquid chromatography column, minimized the fraction of stagnant liquid and resulted in a constant plate height for non-adsorbing species. The uncoupling of dispersion from eluent flow rate enabled the surface chemistry of the stationary phase to be considered separately from fluid transport phenomena and pointed to new ways to apply chemistry for the engineering of rapid bioseparations. This paper addresses developments and current research on fiber-based monoliths and explains how the various forms of this type of chromatographic stationary phase have potential to provide new tools for analytical and preparative scale separations. The different stationary phases are discussed, and a model that captures the observed constant plate height as a function of mobile phase velocity is reviewed. Methods that enable hydrodynamically stable fiber columns to be packed and operated over a range of mobile phase flow rates, together with the development of new fiber chemistries, are shown to provide columns that extend the versatility of liquid chromatography using monoliths, particularly at the preparative scale. Graphical Abstract Schematic representation of a sample mixture being separated by a rolled-stationary phase column, resulting separated peaks shown in the chromatogram.

  5. Comparative study of different approaches for multivariate image analysis in HPTLC fingerprinting of natural products such as plant resin.

    PubMed

    Ristivojević, Petar; Trifković, Jelena; Vovk, Irena; Milojković-Opsenica, Dušanka

    2017-01-01

    Considering the introduction of phytochemical fingerprint analysis, as a method of screening the complex natural products for the presence of most bioactive compounds, use of chemometric classification methods, application of powerful scanning and image capturing and processing devices and algorithms, advancement in development of novel stationary phases as well as various separation modalities, high-performance thin-layer chromatography (HPTLC) fingerprinting is becoming attractive and fruitful field of separation science. Multivariate image analysis is crucial in the light of proper data acquisition. In a current study, different image processing procedures were studied and compared in detail on the example of HPTLC chromatograms of plant resins. In that sense, obtained variables such as gray intensities of pixels along the solvent front, peak area and mean values of peak were used as input data and compared to obtained best classification models. Important steps in image analysis, baseline removal, denoising, target peak alignment and normalization were pointed out. Numerical data set based on mean value of selected bands and intensities of pixels along the solvent front proved to be the most convenient for planar-chromatographic profiling, although required at least the basic knowledge on image processing methodology, and could be proposed for further investigation in HPLTC fingerprinting. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

    PubMed

    Ohta, Kazutoku; Ohashi, Masayoshi; Jin, Ji-Ye; Takeuchi, Toyohide; Fujimoto, Chuzo; Choi, Seong-Ho; Ryoo, Jae-Jeong; Lee, Kwang-Pill

    2003-05-16

    The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

  7. [Influences of ion-suppressors on retention behaviors of nine food additives in reversed-phase high performance liquid chromatographic separation].

    PubMed

    Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong

    2011-10-01

    The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods.

  8. Gas chromatography with simultaneous detection: Ultraviolet spectroscopy, flame ionization, and mass spectrometry.

    PubMed

    Gras, Ronda; Luong, Jim; Haddad, Paul R; Shellie, Robert A

    2018-05-08

    An effective analytical strategy was developed and implemented to exploit the synergy derived from three different detector classes for gas chromatography, namely ultraviolet spectroscopy, flame ionization, and mass spectrometry for volatile compound analysis. This strategy was achieved by successfully hyphenating a user-selectable multi-wavelength diode array detector featuring a positive temperature coefficient thermistor as an isothermal heater to a gas chromatograph. By exploiting the non-destructive nature of the diode array detector, the effluent from the detector was split to two parallel detectors; namely a quadrupole mass spectrometer and a flame ionization detector. This multi-hyphenated configuration with the use of three detectors is a powerful approach not only for selective detection enhancement but also for improvement in structural elucidation of volatile compounds where fewer fragments can be obtained or for isomeric compound analysis. With the diode array detector capable of generating high resolution gas phase spectra, the information collected provides useful confirmatory information without a total dependence on the chromatographic separation process which is based on retention time. This information-rich approach to chromatography is achieved without incurring extra analytical time, resulting in improvements in compound identification accuracy, analytical productivity, and cost. Chromatographic performance obtained from model compounds was found to be acceptable with a relative standard deviation of the retention times of less than 0.01% RSD, and a repeatability at two levels of concentration of 100 and 1000 ppm (v/v) of less than 5% (n = 10). With this configuration, correlation of data between the three detectors was simplified by having near identical retention times for the analytes studied. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Capillary electrophoresis in two-dimensional separation systems: Techniques and applications.

    PubMed

    Kohl, Felix J; Sánchez-Hernández, Laura; Neusüß, Christian

    2015-01-01

    The analysis of complex samples requires powerful separation techniques. Here, 2D chromatographic separation techniques (e.g. LC-LC, GC-GC) are increasingly applied in many fields. Electrophoretic separation techniques show a different selectivity in comparison to LC and GC and very high separation efficiency. Thus, 2D separation systems containing at least one CE-based separation technique are an interesting alternative featuring potentially a high degree of orthogonality. However, the generally small volumes and strong electrical fields in CE require special coupling techniques. These technical developments are reviewed in this work, discussing benefits and drawbacks of offline and online systems. Emphasis is placed on the design of the systems, their coupling, and the detector used. Moreover, the employment of strategies to improve peak capacity, resolution, or sensitivity is highlighted. Various applications of 2D separations with CE are summarized. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Selective filling for patterning in microfluidic channels and integration of chromatography in "lab-on-a-chip" devices using sol-gel technology

    NASA Astrophysics Data System (ADS)

    Jindal, Rohit

    The last decade has seen tremendous advancement in the development of miniaturized chemical analysis system also known as "lab-on-a-chip". It is believed that the true potential of these devices will be achieved by integrating various functions such as separation, reaction, sensing, mixing, pumping, injection and detection onto a single chip. The ability to pattern different functionalities is indispensable for the development of highly integrated devices. In this work, a simple method based on the concept of selective filling is described for patterning in the microfluidic channels. It is based on the difference in the free energy of filling between an open and a covered part of the channel. This method was used for the integration of chromatography in the microfluidic devices. A chromatographic column was realized by utilizing sol-gel as an immobilization matrix for entrapping reversed phase chromatographic particles. Localization of the stationary phase was achieved using the selective filling technique. Channels were fabricated in quartz using photolithography and wet etching. Electroosmotic flow was used for manipulating fluid movement in the channels. Cross channel design was used for making a pulse injection of the solutes in the separation channel. An optical fiber setup was developed for carrying out on-chip UV absorbance detection. Stationary phase was created under different sol-gel synthesis conditions. It was established that the sol-gel synthesis carried out under acidic conditions provides the optimum synthesis conditions for creating separation column. Chromatographic performance of the stationary phase material was demonstrated by separating peptides present in a mixture. The sol-gel immobilization method was extended for the integration of micropump in the chip. The micropump enables pumping of the fluid in field free channels. Preliminary results, demonstrating the potential of carbon nanotubes as a support material in the microfluidic channels, were obtained using CVD (chemical vapor deposition) grown tubes in the channel. Results obtained in this work demonstrate the potential of selective filling technique along with sol-gel technology as a useful tool for the fabrication of multifunctional "lab-on-a-chip" devices.

  11. Unsupervised parameter optimization for automated retention time alignment of severely shifted gas chromatographic data using the piecework alignment algorithm.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pierce, Karisa M.; Wright, Bob W.; Synovec, Robert E.

    2007-02-02

    First, simulated chromatographic separations with declining retention time precision were used to study the performance of the piecewise retention time alignment algorithm and to demonstrate an unsupervised parameter optimization method. The average correlation coefficient between the first chromatogram and every other chromatogram in the data set was used to optimize the alignment parameters. This correlation method does not require a training set, so it is unsupervised and automated. This frees the user from needing to provide class information and makes the alignment algorithm more generally applicable to classifying completely unknown data sets. For a data set of simulated chromatograms wheremore » the average chromatographic peak was shifted past two neighboring peaks between runs, the average correlation coefficient of the raw data was 0.46 ± 0.25. After automated, optimized piecewise alignment, the average correlation coefficient was 0.93 ± 0.02. Additionally, a relative shift metric and principal component analysis (PCA) were used to independently quantify and categorize the alignment performance, respectively. The relative shift metric was defined as four times the standard deviation of a given peak’s retention time in all of the chromatograms, divided by the peak-width-at-base. The raw simulated data sets that were studied contained peaks with average relative shifts ranging between 0.3 and 3.0. Second, a “real” data set of gasoline separations was gathered using three different GC methods to induce severe retention time shifting. In these gasoline separations, retention time precision improved ~8 fold following alignment. Finally, piecewise alignment and the unsupervised correlation optimization method were applied to severely shifted GC separations of reformate distillation fractions. The effect of piecewise alignment on peak heights and peak areas is also reported. Piecewise alignment either did not change the peak height, or caused it to slightly decrease. The average relative difference in peak height after piecewise alignment was –0.20%. Piecewise alignment caused the peak areas to either stay the same, slightly increase, or slightly decrease. The average absolute relative difference in area after piecewise alignment was 0.15%.« less

  12. Rapid, Bioassay-Guided Process for the Detection and Identification of Antibacterial Neem Oil Compounds.

    PubMed

    Krüzselyi, Dániel; Nagy, Róbert; Ott, Péter G; Móricz, Ágnes M

    2016-08-01

    Bioassay guidance was used along the whole process including method development, isolation and identification of antibacterial neem (Azadirachta indica) oil compounds. The biomonitoring was performed by direct bioautography (DB), a combination of thin-layer chromatography (TLC) and antimicrobial detection. DB of neem oil showed one antibacterial zone that was not UV-active; therefore, the TLC separation was improved under DB control. The chromatographic zone that exhibited activity against Bacillus subtilis, Xanthomonas euvesicatoria, Aliivibrio fischeri, Staphylococcus aureus and methicillin-resistant Staphylococcus aureus was characterized by TLC reagents, indicating a lipophilic, fatty acid-like chemical feature. Two compounds were found and identified in the active zone by high-performance liquid chromatography-electrospray ionization mass spectrometry as linoleic and oleic acids. Both fatty acids inhibited B. subtilis, but A. fischeri was sensitive only against linoleic acid. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Production and recovery of monosaccharides from lignocellulose hot water extracts in a pulp mill biorefinery.

    PubMed

    Sainio, Tuomo; Kallioinen, Mari; Nakari, Olli; Mänttäri, Mika

    2013-05-01

    Processing of hemicelluloses obtained with pressurized hot water extraction (PHWE) from Scots pine to monosaccharides and other chemicals was investigated experimentally. A process scheme consisting of ultrafiltration, acid hydrolysis, and chromatographic separation was proposed and evaluated. A two-stage ultrafiltration was found necessary for efficient fractionation of the wood extract. It was shown that the monosaccharides can be released from a concentrated hemicellulose fraction with sulfuric acid hydrolysis without a significant loss of yield due to decomposition of monosaccharides. Acid hydrolysate was successfully fractionated with ion exchange chromatography and the hydrolysis acid was recovered for reuse. The product fractions obtained include polyphenols and high molar mass hemicelluloses (from UF stage 1), arabinose (from UF stage 2), as well as acetic acid and a mixture of monosaccharides (xylose, galactose, mannose, glucose) from chromatography. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Centrifugal precipitation chromatography

    PubMed Central

    Ito, Yoichiro; Lin, Qi

    2009-01-01

    Centrifugal precipitation chromatography separates analytes according their solubility in ammonium sulfate (AS) solution and other precipitants. The separation column is made from a pair of long spiral channels partitioned with a semipermeable membrane. In a typical separation, concentrated ammonium sulfate is eluted through one channel while water is eluted through the other channel in the opposite direction. The countercurrent process forms an exponential AS concentration gradient through the water channel. Consequently, protein samples injected into the water channel is subjected to a steadily increasing AS concentration and at the critical AS concentration they are precipitated and deposited in the channel bed by the centrifugal force. Then the chromatographic separation is started by gradually reducing the AS concentration in the AS channel which lowers the AS gradient concentration in the water channel. This results in dissolution of deposited proteins which are again precipitated at an advanced critical point as they move through the channel. Consequently, proteins repeat precipitation and dissolution through a long channel and finally eluted out from the column in the order of their solubility in the AS solution. The present method has been successfully applied to a number of analytes including human serum proteins, recombinant ketosteroid isomerase, carotenoid cleavage enzymes, plasmid DNA, polysaccharide, polymerized pigments, PEG-protein conjugates, etc. The method is capable to single out the target species of proteins by affinity ligand or immunoaffinity separation. PMID:19541553

  15. A narrow open tubular column for high efficiency liquid chromatographic separation

    DOE PAGES

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen; ...

    2018-01-01

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow ( e.g. , 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar.

  16. A NEW HPLC METHOD FOR SEPARATION OF PHYTOPLANKTON PIGMENTS IN NATURAL SAMPLES

    EPA Science Inventory

    A new high-performance liquid chromatographic (HPLC) method was developed to analyze, in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a reverse-phase amide C16 (RP-amide C16) column and an elution gradient o...

  17. UTILITY OF THREE TYPES OF MASS SPECTROMETERS FOR DETERMINING ELEMENTAL COMPOSITIONS OF IONS FORMED FROM CHROMATOGRAPHICALLY SEPARATED COMPOUNDS

    EPA Science Inventory

    Sponsor Referee: Douglas F. Barofsky, Oregon State University Concentration factors of 1000 and more reveal dozens of compounds in extracts of water supplies. Library mass spectra for most of these compounds are not available, and alternative means of identification are needed. D...

  18. A narrow open tubular column for high efficiency liquid chromatographic separation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Huang; Yang, Yu; Qiao, Zhenzhen

    We report a great feature of open tubular liquid chromatography when it is run using an extremely narrow ( e.g. , 2 μm inner diameter) open tubular column: more than 10 million plates per meter can be achieved in less than 10 min and under an elution pressure of ca. 20 bar.

  19. Rapid and cost-effective determination of acrylamide in coffee by planar chromatography and fluorescence detection after derivatization with dansulfinic acid.

    PubMed

    Alpmann, Alexander; Morlock, Gertrud

    2009-01-01

    A new method has been developed for the determination of acrylamide in ground coffee by planar chromatography using prechromatographic in situ derivatization with dansulfinic acid. After pressurized fluid extraction of acrylamide from the coffee samples, the extracts were passed through activated carbon and concentrated. These extracts were applied onto a silica gel 60 HPTLC plate and oversprayed with dansulfinic acid. By heating the plate, acrylamide was derivatized into the fluorescent product dansylpropanamide. The chromatographic separation with ethyl acetate-tert.-butyl methyl ether (8 + 2, v/v) mobile phase was followed by densitometric quantification at 254/>400 nm using a 4 point calibration via the standard addition method over the whole system for which acrylamide was added at different concentrations at the beginning of the extraction process. The method was validated for commercial coffee. The linearity over the whole procedure showed determination coefficients between 0.9995 and 0.9825 (n = 6). Limit of quantitation at a signal-to-noise ratio of 10 was determined to be 48 microg/kg. The within-run precision (relative standard deviation, n = 6) of the chromatographic method was 3%. Commercial coffee samples analyzed showed acrylamide contents between 52 and 191 microg/kg, which was in correlation with amounts reported in previous publications.

  20. High-performance thin-layer chromatography and three-dimensional image analysis for the determination of rutin in pharmaceutical preparations.

    PubMed

    Soponar, Florin; Moţ, Augustin C; Sârbu, Costel

    2010-01-01

    A novel HPTLC method was developed for fast and simple quantitative determination of rutin in pharmaceutical preparations. The proposed method combines the advantages of HPTLC with the comfort and the convenience of digital processing of images. For the separation of rutin, silica gel with attached amino groups was used as the stationary phase and ethyl acetate-formic acid-methanol-water (10 + 0.9 + 1.1 + 1.7, v/v/v/v) as the mobile phase. The chromatographic plate was sprayed with 2-aminoethyldiphenyl borate solution for visual detection of the spots. For the construction of a three-dimensional chromatogram, Melanie 7.0 software was used together with an HP flatbed scanner that allowed capture of the images on chromatographic plates. The calibration curve was linear within the range of 0.95-4.78 microg/spot with an r value of 0.9984. The RSD for six replicates at three concentration levels was less than 3%, while the recovery was between 97.28 and 103.27%. The proposed method was found to be simple, precise, sensitive, and accurate and has been applied for the determination of rutin in two commercial drugs. The results were compared with the results of other techniques that generate bidimensional chromatograms and validated by UV-Vis spectrophotometry.

  1. 3-methylcyclohexanone thiosemicarbazone: determination of E/Z isomerization barrier by dynamic high-performance liquid chromatography, configuration assignment and theoretical study of the mechanisms involved by the spontaneous, acid and base catalyzed processes.

    PubMed

    Carradori, Simone; Cirilli, Roberto; Dei Cicchi, Simona; Ferretti, Rosella; Menta, Sergio; Pierini, Marco; Secci, Daniela

    2012-12-21

    Here, we report on the simultaneous direct HPLC diastereo- and enantioseparation of 3-methylcyclohexanone thiosemicarbazone (3-MCET) on a polysaccharide-based chiral stationary phase under normal-phase conditions. The optimized chromatographic system was employed in dynamic HPLC experiments (DHPLC), as well as detection technique in a batch wise approach to determine the rate constants and the corresponding free energy activation barriers of the spontaneous, base- and acid-promoted E/Z diastereomerization of 3-MCET. The stereochemical characterization of four stereoisomers of 3-MCET was fully accomplished by integrating the results obtained by chemical correlation method with those derived by theoretical calculations and experimental investigations of circular dichroism (CD). As a final goal, a deepened analysis of the perturbing effect exercised by the stationary phase on rate constant values measured through DHPLC determinations as a function of the chromatographic separation factor α of the interconverting species was successfully accomplished. This revealed quite small deviations from the equivalent kinetic values obtained by off-column batch wise procedure, and suggested a possible effective correction of rate constants measured by DHPLC approach. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Application of a newly developed and validated high-performance thin-layer chromatographic method to control honey adulteration.

    PubMed

    Puscas, Anitta; Hosu, Anamaria; Cimpoiu, Claudia

    2013-01-11

    Honey is a saturated solution of sugars, used for a long time as a natural source of sugars and is an important ingredient in traditional medicine due to its antimicrobial, anti-inflammatory and antioxidant effects. Therefore, methods for quality control of honey and detection of its adulteration are very important. For this reason, the aim of this study is to develop and validate a new, simple and economical analytical method for detecting the adulteration of some Romanian honeys based on high-performance thin-layer chromatography (HPTLC) combined with image analysis. The proposed method involved the chromatographic separations of glucose, fructose and sucrose on silica gel HPTLC plates, developed twice with ethyl acetate-pyridine-water-acetic acid, 6:3:1:0.5 (v/v/v/v), followed by dipping in an immersion solution. The documentation of plates was performed using TLC visualization device and the images of plates were processed using a digital processor. The developed HPTLC method was validated for selectivity, linearity and range, LOD and LOQ, precision, robustness and accuracy. The method was then applied for quantitative determination of glucose, fructose and sucrose from different types of Romanian honeys, commercially available. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. [Experimental study of metabonomics in the diagnosis of allergic rhinitis in mice].

    PubMed

    Wang, A; Li, Q F; Zhang, G Q; Zhao, C Q

    2016-02-01

    To investigate the application of metabonomics in the diagnosis of allergic rhinitis. Eighty male Kunming mice were randomly divided into two groups, control group (30 mice) and allergic rhinitis (AR) group (50 mice). After modeling, removal behavior score more than 6 and retain 30 mice behavior score equal to 6.Collect the mice peripheral blood and preparate blood serum, using UPLC-MS chromatographic separation and detection. The data were pretreated by SPSS and Excel, after chromatographic peak matching by MZmine. Firstly , delete interference data in accordance with the 80% rule .Then, the investigate data were analyzed by PLS-DA and PCA-X. Three-dimensional view of the control group (30 mice) and AR group (30 mice) blood serum data was drawn using PCA-X and PLS-DA method. The two groups of samples could be completely separated through views, which showed that there was a significant difference between the two groups of data. There were some differences in the blood metabolites between the control group and AR group . The study showed that it was scientific and feasible to diagnose AR using the metabonomics.

  4. Precolumn derivatization followed by liquid chromatographic separation and determination of tramiprosate in rat plasma by fluorescence detector: application to pharmacokinetics.

    PubMed

    Rao, R Nageswara; Maurya, Pawan K; Shinde, Dhananjay D; Khalid, Sara

    2011-05-15

    Alzheimer disease (AD) is characterized pathologically by extracellular amyloid deposits composed of amyloid β (Aβ) protein. A simple and rapid method using HPLC with fluorescence detector was developed and validated for determination of tramiprosate in rat plasma. Pre-column derivatization of the deproteinized rat plasma was carried out using o-phthaldialdehyde (OPA) as a fluorescent reagent in presence of 3-mercaptopropionic acid. The liquid chromatographic separation was achieved on a Kromasil C18 column using methanol:acetonitrile: 20 mM phosphate buffer pH 7.5 (8.0:17.5:74.5 v/v/v) as a mobile phase in an isocratic elution mode. The eluents were monitored by a fluorescence detector set at 330 and 450 nm of excitation and emission wavelength respectively. Vigabatrin was used as an internal standard. The method was linear within the range 30.0-1000.0 ng/mL. Design of experiments (DOE) was used to evaluate the robustness of the method. The developed method was applied to study the pharmacokinetics of tramiprosate in rats. Copyright © 2011. Published by Elsevier B.V.

  5. Chromatographic and electrophoretic methods for Lingzhi pharmacologically active components.

    PubMed

    Huie, Carmen W; Di, Xin

    2004-12-05

    Lingzhi is the Chinese name given to the Ganoderma family of mushrooms, which was considered the most valuable medicine in ancient China and was believed to bring longevity, due to its mysterious power of healing the body and calming the mind. Today, Lingzhi is still widely revered as a valuable health supplement and herbal medicine worldwide, as studies (mostly conducted in China, Korea, Japan and the United States) into the medicinal and nutritional values of Lingzhi revealed that it does indeed contain certain bioactive ingredients (such as triterpenes and polysaccharides) that might be beneficial for the prevention and treatment of a variety of ailments, including important diseases such as hypertension, diabetes, hepatitis, cancers, and AIDS. As research into the biological activities of Lingzhi, as well as the quality assurance and quality control of Lingzhi products, require the isolation/purification of active ingredients from Lingzhi, followed by subsequent analytical and/or preparative separations, the present review summarizes the various chromatographic and electrophoretic methods (as well as sample pretreatment methods) typically employed to achieve such extraction/separation procedures.

  6. Rapid Isocratic Liquid Chromatographic Separation and Quantification of Tryptophan and Six kynurenine Metabolites in Biological Samples with Ultraviolet and Fluorimetric Detection

    PubMed Central

    Badawy, Abdulla A-B; Morgan, Christopher J

    2010-01-01

    A simple, rapid isocratic liquid chromatographic procedure with ultraviolet and fluorimetric detection is described for the separation and quantification of L-tryptophan (Trp) and six of its kynurenine metabolites (kynurenine, 3-hydroxykynurenine, and 3-hydroxyanthranilic, kynurenic, xanthurenic and anthranilic acids). Using the Perkin Elmer LC 200 system, a reverse phase Synergi 4 μ fusion-RP80 A column (250 × 4.6 mm) (Phenomenex), and a mobile phase of 10 mM sodium dihydrogen phosphate: methanol (73:27, by vol) at pH 2.8 and a flow rate of 1.0–1.2 ml/min at 37 °C, a run took ∼13 min. The run took <7 min at 40 °C and a 1.4 ml/min flow rate. Limits of detection of all 7 analytes were 5–72 nM and their recoveries from human plasma and rat serum and liver varied between 62% and 111%. This simple method is suitable for high throughput work and can be further developed to include quinolinic acid and other Trp metabolites. PMID:22084598

  7. On the use of ionic liquids as mobile phase additives in high-performance liquid chromatography. A review.

    PubMed

    García-Alvarez-Coque, M C; Ruiz-Angel, M J; Berthod, A; Carda-Broch, S

    2015-07-09

    The popularity of ionic liquids (ILs) has grown during the last decades in several analytical separation techniques. Consequently, the number of reports devoted to the applications of ILs is still increasing. This review is focused on the use of ILs (mainly imidazolium-based associated to chloride and tetrafluoroborate) as mobile phase additives in high-performance liquid chromatography (HPLC). In this approach, ILs just function as salts, but keep several kinds of intermolecular interactions, which are useful for chromatographic separations. Both cation and anion can be adsorbed on the stationary phase, creating a bilayer. This gives rise to hydrophobic, electrostatic and other specific interactions with the stationary phase and solutes, which modify the retention behaviour and peak shape. This review updates the advances in this field, with emphasis on topics not always deeply considered in the literature, such as the mechanisms of retention, the estimation of the suppressing potency of silanols, modelling and optimisation of the chromatographic performance, and the comparison with other additives traditionally used to avoid the silanol problem. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Synthesis, liquid chromatographic fractionation and partial characterization of polybrominated dibenzofuran congeners.

    PubMed

    Gallistl, Christoph; Vetter, Walter

    2016-04-15

    Polybrominated dibenzofurans (PBDFs) are a class of highly toxic environmental contaminants which comprises 135 structurally different congeners. While the gas chromatographic separation and analysis of the most polychlorinated dibenzofurans (PCDFs) are well-documented, comparably little data is currently available in the case of PBDFs. In this study dibenzofuran was brominated to give a mixture of ∼40 PBDFs with one to seven bromine atoms. This synthesis mixture was fractionated by both countercurrent chromatography (CCC) with the solvent system n-hexane/toluene/acetonitrile and non-aqueous reversed-phase high performance liquid chromatography (RP-HPLC) with acetonitrile as the mobile phase. All together 80 consecutive CCC fractions and 40 HPLC fractions were taken and analyzed for PBDFs by gas chromatography coupled to mass spectrometry (GC/MS). CCC and RP-HPLC offered orthogonal separation of the PBDF mixture. As a consequence, selected CCC fractions were further fractionated by RP-HPLC. In this way, eight PBDFs could be isolated and the structures of twelve PBDFs were elucidated by proton magnetic resonance spectroscopy ((1)H NMR). Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    PubMed

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  10. Comparison of twin-cell centrifugal partition chromatographic columns with different cell volume.

    PubMed

    Goll, Johannes; Audo, Gregoire; Minceva, Mirjana

    2015-08-07

    Two twin-cell centrifugal partition chromatographic columns (SCPC 250 and SCPE-250-BIO, Armen Instrument, France) with the same column volume but different cell size and number were compared in terms of stationary phase retention and column efficiency. The columns were tested with two types of solvent systems: a commonly used organic solvent based biphasic system from the ARIZONA solvent system family and a polymer/salt based aqueous two phase system (ATPS). The efficiency of the columns was evaluated by pulse injection experiments of two benzenediols (pyrocatechol and hydroquinone) in the case of the ARIZONA system and a protein mixture (myoglobin and lysozyme) in the case of the ATPS. As result of high stationary phase retention, the column with the lower number of larger twin-cells (SCPE-250-BIO) is suitable for protein separations using ATPS. On the other hand, due to higher column efficiency, the column with the greater number of smaller cells (SCPC 250) is superior for batch elution separations performed with standard liquid-liquid chromatography organic solvent based biphasic systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Ion-exclusion chromatography with conductimetric detection of aliphatic carboxylic acids on a weakly acidic cation-exchange resin by elution with benzoic acid-beta-cyclodextrin.

    PubMed

    Tanaka, Kazuhiko; Mori, Masanobu; Xu, Qun; Helaleh, Murad I H; Ikedo, Mikaru; Taoda, Hiroshi; Hu, Wenzhi; Hasebe, Kiyoshi; Fritz, James S; Haddad, Paul R

    2003-05-16

    In this study, an aqueous solution consisting of benzoic acid with low background conductivity and beta-cyclodextrin (beta-CD) of hydrophilic nature and the inclusion effect to benzoic acid were used as eluent for the ion-exclusion chromatographic separation of aliphatic carboxylic acids with different pKa values and hydrophobicity on a polymethacrylate-based weakly acidic cation-exchange resin in the H+ form. With increasing concentration of beta-cyclodextrin in the eluent, the retention times of the carboxylic acids decreased due to the increased hydrophilicity of the polymethacrylate-based cation-exchange resin surface from the adsorption of OH groups of beta-cyclodextrin. Moreover, the eluent background conductivity decreased with increasing concentration of beta-cyclodextrin in 1 mM benzoic acid, which could result in higher sensitivity for conductimetric detection. The ion-exclusion chromatographic separation of carboxylic acids with high resolution and sensitivity was accomplished successfully by elution with a 1 mM benzoic acid-10 mM cyclodextrin solution without chemical suppression.

  12. Fabrication of powdery polymer aerogel as the stationary phase for high-resolution gas chromatographic separation.

    PubMed

    Zheng, Juan; Lu, Cuiming; Huang, Junlong; Chen, Luyi; Ni, Chuyi; Xie, Xintong; Zhu, Fang; Wu, Dingcai; Ouyang, Gangfeng

    2018-08-15

    Novel powdery polymer aerogel (PPA) prepared via the (micro)emulsion polymerization and the following hyper crosslinking reaction was fabricated as stationary phase of capillary column for the first time. Due to its powdery morphology, unique 3D nano-network structure, high surface area and good thermostability, the PPA-coated capillary column demonstrated high-resolution chromatographic separation towards nonpolar and weakly polar organic compounds, including benzene series, n-alkanes, ketone mixtures and trichlorobenzenes. Moreover, the reproducibility, quantitative analysis ability and thermostability of PPA-coated capillary column were also evaluated. The relative standard deviations for three replicate determinations of selected analytes were 0.02-0.11%, 0.12-0.26% and 1.2-3.6% for run-to-run, day-to-day and column-to-column analyses, respectively. The PPA demonstrated good thermostability, and the PPA-coated capillary column was proved to be heat-resistant (270 °C). The results of this study show PPA is an excellent candidate to be employed as stationary phase for gas chromatography capillary. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Novel chromatographic separation and carbon solid-phase extraction of acetanilide herbicide degradation products.

    PubMed

    Shoemaker, Jody A

    2002-01-01

    One acetamide and 5 acetanilide herbicides are currently registered for use in the United States. Over the past several years, ethanesulfonic acid (ESA) and oxanilic acid (OA) degradation products of these acetanilide/acetamide herbicides have been found in U.S. ground waters and surface waters. Alachlor ESA and other acetanilide degradation products are listed on the U.S. Environmental Protection Agency's (EPA) 1998 Drinking Water Contaminant Candidate List. Consequently, EPA is interested in obtaining national occurrence data for these contaminants in drinking water. EPA currently does not have a method for determining these acetanilide degradation products in drinking water; therefore, a research method is being developed using liquid chromatography/negative ion electrospray/mass spectrometry with solid-phase extraction (SPE). A novel chromatographic separation of the acetochlor/alachlor ESA and OA structural isomers was developed which uses an ammonium acetate-methanol gradient combined with heating the analytical column to 70 degrees C. Twelve acetanilide degradates were extracted by SPE from 100 mL water samples using carbon cartridges with mean recoveries >90% and relative standard deviations < or =16%.

  14. Differentiating Positional Isomers of Nucleoside Modifications by Higher-Energy Collisional Dissociation Mass Spectrometry (HCD MS)

    NASA Astrophysics Data System (ADS)

    Jora, Manasses; Burns, Andrew P.; Ross, Robert L.; Lobue, Peter A.; Zhao, Ruoxia; Palumbo, Cody M.; Beal, Peter A.; Addepalli, Balasubrahmanyam; Limbach, Patrick A.

    2018-06-01

    The analytical identification of positional isomers (e.g., 3-, N 4-, 5-methylcytidine) within the > 160 different post-transcriptional modifications found in RNA can be challenging. Conventional liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) approaches rely on chromatographic separation for accurate identification because the collision-induced dissociation (CID) mass spectra of these isomers nearly exclusively yield identical nucleobase ions (BH2 +) from the same molecular ion (MH+). Here, we have explored higher-energy collisional dissociation (HCD) as an alternative fragmentation technique to generate more informative product ions that can be used to differentiate positional isomers. LC-MS/MS of modified nucleosides characterized using HCD led to the creation of structure- and HCD energy-specific fragmentation patterns that generated unique fingerprints, which can be used to identify individual positional isomers even when they cannot be separated chromatographically. While particularly useful for identifying positional isomers, the fingerprinting capabilities enabled by HCD also offer the potential to generate HPLC-independent spectral libraries for the rapid analysis of modified ribonucleosides. [Figure not available: see fulltext.

  15. Research for amino acids in lunar samples.

    NASA Technical Reports Server (NTRS)

    Gehrke, C. W.; Zumwalt, R. W.; Kuo, K.; Rash, J. J.; Aue , W. A.; Stalling, D. L.; Kvenvolden, K. A.; Ponnamperuma, C.

    1972-01-01

    The study was primarily directed toward the examination of Apollo 14 lunar fines for indigenous amino acids or materials which could be converted to amino acids on hydrolysis with 6 N hydrochloric acid. Initial experiments were conducted to confirm the integrity of the derivatization reactions and reagents, and to optimize the gas-liquid chromatographic (GLC) instrumental and chromatographic system for the separation and flame ionization detection of the amino acid derivatives. In studies on the recovery of amino acids added to lunar fines, low recoveries were obtained when 10 ng of each amino acid were added to 50 mg of virgin fines, but the subsequent addition of 50 ng of each to the previously extracted sample resulted in much higher recoveries.

  16. Influence of continuous magnetic field on the separation of ephedrine enantiomers by molecularly imprinted polymers.

    PubMed

    Guerreiro, António R; Korkhov, Vadim; Mijangos, Irene; Piletska, Elena V; Rodins, Juris; Turner, Anthony P F; Piletsky, Sergey A

    2008-02-28

    A set of polymers was imprinted with (-)-ephedrine using UV initiation, under the influence of a constant external magnetic field with intensities ranging from 0 to 1.55 T. Synthesised materials were characterised by X-ray crystallography, infrared spectroscopy, swelling and surface area. Recognition properties were assessed by the ability to discriminate between (+) and (-)-ephedrine and by Scatchard analyses on chromatographic mode. It was shown that polymer morphology and recognition properties are affected by the magnetic field. This resulted in considerable improvements in the chromatographic resolution of ephedrine enantiomers by materials synthesised under the influence of magnetic field. Apparently the magnetic field improved the ordering of the polymer structure and facilitated the formation of more uniform imprinting sites.

  17. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    PubMed

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  18. Quantification of urinary uric acid in the presence of thymol and thimerosal by high-performance liquid chromatography

    NASA Technical Reports Server (NTRS)

    Chen, Y.; Pietrzyk, R. A.; Whitson, P. A.

    1997-01-01

    A high-performance liquid chromatographic method was developed as an alternative to automated enzymatic analysis of uric acid in human urine preserved with thymol and/or thimerosal. Uric acid (tR = 10 min) and creatinine (tR = 5 min) were separated and quantified during isocratic elution (0.025 M acetate buffer, pH 4.5) from a mu Bondapak C18 column. The uric-acid peak was identified chemically by incubating urine samples with uricase. The thymol/thimerosal peak appeared at 31 min during the washing step and did not interfere with the analysis. We validated the high-performance liquid chromatographic method for linearity, precision and accuracy, and the results were found to be excellent.

  19. Chiral separation of a diketopiperazine pheromone from marine diatoms using supercritical fluid chromatography.

    PubMed

    Frenkel, Johannes; Wess, Carsten; Vyverman, Wim; Pohnert, Georg

    2014-03-01

    The proline derived diketopiperazine has been identified in plants, insects and fungi with unknown function and was recently also reported as the first pheromone from a diatom. Nevertheless the stereochemistry and enantiomeric excess of this natural product remained inaccessible using direct analytical methods. Here we introduce a chiral separation of this metabolite using supercritical fluid chromatography/mass spectrometry. Several chromatographic methods for chiral analysis of the diketopiperazine from the diatom Seminavis robusta and synthetic enantiomers have been evaluated but neither gas chromatography nor high performance liquid chromatography on different chiral cyclodextrin phases were successful in separating the enantiomers. In contrast, supercritical fluid chromatography achieved baseline separation within four minutes of run time using amylose tris(3,5-dimethylphenylcarbamate) as stationary phase and 2-propanol/CO2 as mobile phase. This very rapid chromatographic method in combination with ESI mass spectrometry allowed the direct analysis of the cyclic dipeptide out of the complex sea water matrix after SPE enrichment. The method could be used to determine the enantiomeric excess of freshly released pheromone and to follow the rapid degradation observed in diatom cultures. Initially only trace amounts of c(d-Pro-d-Pro) were found besides the dominant c(l-Pro-l-Pro) in the medium. However the enantiomeric excess decreased upon pheromone degradation within few hours indicating that a preferential conversion and thus inactivation of the l-proline derived natural product takes place. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Generation of accurate peptide retention data for targeted and data independent quantitative LC-MS analysis: Chromatographic lessons in proteomics.

    PubMed

    Krokhin, Oleg V; Spicer, Vic

    2016-12-01

    The emergence of data-independent quantitative LC-MS/MS analysis protocols further highlights the importance of high-quality reproducible chromatographic procedures. Knowing, controlling and being able to predict the effect of multiple factors that alter peptide RP-HPLC separation selectivity is critical for successful data collection for the construction of ion libraries. Proteomic researchers have often regarded RP-HPLC as a "black box", while vast amount of research on peptide separation is readily available. In addition to obvious parameters, such as the type of ion-pairing modifier, stationary phase and column temperature, we describe the "mysterious" effects of gradient slope, column size and flow rate on peptide separation selectivity. Retention time variations due to these parameters are governed by the linear solvent strength (LSS) theory on a peptide level by the value of its slope S in the basic LSS equation-a parameter that can be accurately predicted. Thus, the application of shallower gradients, higher flow rates, or smaller columns will each increases the relative retention of peptides with higher S-values (long species with multiple positively charged groups). Simultaneous changes to these parameters that each drive shifts in separation selectivity in the same direction should be avoided. The unification of terminology represents another pressing issue in this field of applied proteomics that should be addressed to facilitate further progress. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Top