Norwood, Daniel L; Mullis, James O; Davis, Mark; Pennino, Scott; Egert, Thomas; Gonnella, Nina C
2013-01-01
The structural analysis (i.e., identification) of organic chemical entities leached into drug product formulations has traditionally been accomplished with techniques involving the combination of chromatography with mass spectrometry. These include gas chromatography/mass spectrometry (GC/MS) for volatile and semi-volatile compounds, and various forms of liquid chromatography/mass spectrometry (LC/MS or HPLC/MS) for semi-volatile and relatively non-volatile compounds. GC/MS and LC/MS techniques are complementary for structural analysis of leachables and potentially leachable organic compounds produced via laboratory extraction of pharmaceutical container closure/delivery system components and corresponding materials of construction. Both hyphenated analytical techniques possess the separating capability, compound specific detection attributes, and sensitivity required to effectively analyze complex mixtures of trace level organic compounds. However, hyphenated techniques based on mass spectrometry are limited by the inability to determine complete bond connectivity, the inability to distinguish between many types of structural isomers, and the inability to unambiguously determine aromatic substitution patterns. Nuclear magnetic resonance spectroscopy (NMR) does not have these limitations; hence it can serve as a complement to mass spectrometry. However, NMR technology is inherently insensitive and its ability to interface with chromatography has been historically challenging. This article describes the application of NMR coupled with liquid chromatography and automated solid phase extraction (SPE-LC/NMR) to the structural analysis of extractable organic compounds from a pharmaceutical packaging material of construction. The SPE-LC/NMR technology combined with micro-cryoprobe technology afforded the sensitivity and sample mass required for full structure elucidation. Optimization of the SPE-LC/NMR analytical method was achieved using a series of model compounds representing the chemical diversity of extractables. This study demonstrates the complementary nature of SPE-LC/NMR with LC/MS for this particular pharmaceutical application. The identification of impurities leached into drugs from the components and materials associated with pharmaceutical containers, packaging components, and materials has historically been done using laboratory techniques based on the combination of chromatography with mass spectrometry. Such analytical techniques are widely recognized as having the selectivity and sensitivity required to separate the complex mixtures of impurities often encountered in such identification studies, including both the identification of leachable impurities as well as potential leachable impurities produced by laboratory extraction of packaging components and materials. However, while mass spectrometry-based analytical techniques have limitations for this application, newer analytical techniques based on the combination of chromatography with nuclear magnetic resonance spectroscopy provide an added dimension of structural definition. This article describes the development, optimization, and application of an analytical technique based on the combination of chromatography and nuclear magnetic resonance spectroscopy to the identification of potential leachable impurities from a pharmaceutical packaging material. The complementary nature of the analytical techniques for this particular pharmaceutical application is demonstrated.
Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...
Oellig, Claudia; Schwack, Wolfgang
2012-10-19
Efficient clean-up is indispensable for preventing matrix effects in multi-residue analysis of pesticides in food by liquid and gas chromatography (LC and GC) coupled to mass spectrometry (MS). High-throughput planar solid phase extraction (HTpSPE) was recently introduced as a new clean-up concept in residue analysis of pesticides in fruit and vegetables (C. Oellig, W. Schwack, 2011 [45]). Thin-layer chromatography (TLC) was used to completely separate pesticides from matrix compounds and to focus them into a sharp zone, followed by extraction of the target zone by the TLC-MS interface. As rather challenging matrices, tea samples were chosen in this study. Besides chlorophylls and polyphenols, high amount of caffeine is co-extracted resulting in strong matrix effects both in LC-MS and GC-MS. The former HTpSPE procedure was adapted to initial extracts of green and black tea resulting in colorless extracts nearly free of matrix effects and interferences, as shown for seven chemically representative pesticides (acetamiprid, penconazole, azoxystrobin, chlorpyrifos, pirimicarb, fenarimol, and mepanipyrim). LC-MS/MS calibration curves obtained in the range of 0.002-0.5 mg/kg from matrix-matched standards and solvent standards were nearly identical and demonstrated the effectiveness of clean-up by HTpSPE. Mean recoveries determined by LC-MS/MS against solvent standards at spiking levels of 0.01 and 0.1 mg/kg ranged between 72 and 114% with relative standard deviations (RSDs) of 0.7-4.7% (n=4), while LC-MS measurements of tea samples spiked at 1 mg/kg provided recoveries of 81-104% with RSDs of 1.2-4.9% (n=6). Using LC-MS/MS, the method showed high sensitivity with signal-to-noise ratios>10 for concentrations below 0.002 mg/kg. HTpSPE of one sample was done in a few minutes, while numerous samples were cleaned in parallel at minimal costs with very low sample and solvent consumption. Copyright © 2012 Elsevier B.V. All rights reserved.
Robandt, P V; Bui, H M; Scancella, J M; Klette, K L
2010-10-01
An automated solid-phase extraction-liquid chromatography- tandem mass spectrometry (SPE-LC-MS-MS) method using the Spark Holland Symbiosis Pharma SPE-LC coupled to a Waters Quattro Micro MS-MS was developed for the analysis of 6-acetylmorphine (6-AM) in human urine specimens. The method was linear (R² = 0.9983) to 100 ng/mL, with no carryover at 200 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision calculated as percent coefficient of variation (%CV) and evaluated by analyzing five specimens at 10 ng/mL over nine batches (n = 45) was 3.6%. Intrarun precision evaluated from 0 to 100 ng/mL ranged from 1.0 to 4.4%CV. Other opioids (codeine, morphine, oxycodone, oxymorphone, hydromorphone, hydrocodone, and norcodeine) did not interfere in the detection, quantification, or chromatography of 6-AM or the deuterated internal standard. The quantified values for 41 authentic human urine specimens previously found to contain 6-AM by a validated gas chromatography (GC)-MS method were compared to those obtained by the SPE-LC-MS-MS method. The SPE-LC-MS-MS procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. The time required for extraction and analysis was reduced by approximately 50% when compared to a validated 6-AM procedure using manual SPE and GC-MS analysis.
Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio
2015-04-07
This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.
Dinh, Quoc Tuc; Alliot, Fabrice; Moreau-Guigon, Elodie; Eurin, Joëlle; Chevreuil, Marc; Labadie, Pierre
2011-09-15
This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L(-1). This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L(-1)). Copyright © 2011 Elsevier B.V. All rights reserved.
Khan, Kashif Maqbool; Nahar, Lutfun; Mannan, Abdul; Arfan, Muhammad; Khan, Ghazanfar Ali; Al-Groshi, Afaf; Evans, Andrew; Dempster, Nicola M; Ismail, Fyaz M D; Sarker, Satyajit D
2018-01-01
Asparagus adscendens Roxb. (Asparagaceae), is native to the Himalayas. This plant has been used in the prevention and effective treatment of various forms of cancers. This paper reports, for the first time, on the cytotoxicity of the methanol (MeOH) extract of the roots of A. adscendens and its solid-phase extraction (SPE) fractions against four human carcinoma cell lines and LC-ESI-QTOF-MS analysis of the SPE fractions. Finely powdered roots of A. adscendens were macerated in methanol and extracted through SPE using gradient solvent system (water: methanol) proceeded for analysis on LC-ESI-QTOF-MS and cytotoxicity against four human carcinoma cell lines: breast (MCF7), liver (HEPG2), lung (A549), and urinary bladder (EJ138), using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide assay. The MeOH extract and four SPE fractions exhibited cytotoxicity against all cell lines with the IC 50 values ranging from 6 to 79 μg/mL. As observed in other Asparagus species, the presence of saponins and sapogenins in the SPE fractions was evident in the liquid chromatography-mass spectrometry data. It is reasonable to assume that the cytotoxicity of the MeOH extract of the roots of A. adscendens and its SPE fractions, at least partly, due to the presence of saponins and their aglycones. This suggests that A. adscendens could be exploited as a potential source of cytotoxic compounds with putative anticancer potential. The MeOH extract and all solid-phase extraction (SPE) fractions exhibited various levels of cytotoxicity against all cell lines with the IC 50 values ranging from 6 to 79 μg/mLThe presence of saponins and sapogenins in the SPE fractions was evident in the Liquid chromatography-mass spectrometry dataDue to the presence of saponins and their aglycones, suggest that A. adscendens could be exploited as a potential source of cytotoxic compounds with putative anticancer potential. Abbreviation used: SPE: Solid-phase extraction, MCF7: Breast cancer cell line, HEPG2: Liver cancer cell line, A549: Lung liver cancer cell line, EJ138: Urinary bladder cancer cell line, MTT: 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide, LC-MS: Liquid chromatography-mass spectrometry.
Oshima, Harumi; Ueno, Eiji; Saito, Isao; Matsumoto, Hiroshi
2004-01-01
A simple solid-phase extraction (SPE) method was developed for the liquid chromatography (LC) determination of pheophorbide (Phor) a and pyropheophorbide (Pyro) a in health foods such as chlorella, spirulina, etc. The food sample was extracted with 85% (v/v) acetone. The extract was acidified with hydrochloric acid and loaded on a C18 cartridge. After washing with water, Phor a and Pyro a were eluted with the LC mobile phase. Phor a and Pyro a were separated by isocratic reversed-phase LC and quantitated by fluorescence detection. The recoveries for spiked samples of chlorella and the extract were 87.1-102.0%. Commercial health foods (chlorella, spirulina, aloe, kale, Jews mallow, and green tea leaves) were analyzed using the SPE method. The values found for Phor a and Pyro a ranged from 2 to 788 microg/g and from <1 to 24 microg/g, respectively. There was no significant difference between the SPE method and the official method in Japan (spectrophotometry after liquid-liquid extraction). The advantages of the SPE method are the short extraction times, lack of emulsions, and reduced consumption of organic solvents compared with the official method in Japan. The SPE method is considered to be useful for the screening of Phor a and Pyro a in health foods.
Bosire, G. O.; Ngila, J. C.; Parshotam, H.
2016-01-01
The extraction and determination of aliphatic and aromatic carboxylic acids as well as their influence on the aromaticity and molecularity relationship of natural organic matter (NOM) in water are reported in this study. Three solid phase extraction (SPE) sorbents were used and their extraction efficiencies evaluated after chromatographic determinations (using gas chromatography with a time of flight mass spectrometer (GC × GC-TOFMS) and liquid chromatography with organic carbon detector (LC-OCD)). More than 42 carboxylic acids were identified in raw water from the Vaal River, which feeds the Lethabo Power Generation Station, South Africa, with cooling water. The aromatic carboxylic acid efficiency (28%) was achieved by using Strata™ X SPE while the highest aliphatic carboxylic acid efficiency (92.08%) was achieved by silica SPE. The hydrophobic nature of NOM in water depends on the nature of organic compounds in water, whether aromatic or aliphatic. The LC-OCD was used to assess the hydrophobicity levels of NOM as a function of these carboxylic acids in cooling water. The LC-OCD results showed that the aromatic nature of NOM in SPE filtered water followed the order Silica>Strata X>C-18. From the results, the hydrophobicity degree of the samples depended on the type and number of carboxylic acids that were removed by the SPE cartridges. PMID:27274730
Gielecińska, Iwona; Mojska, Hanna
2013-01-01
Numerous studies have demonstrated acrylamide to be both neurotoxic and carcinogenic. At present it is widely recognised that acrylamide is mainly formed through the Maillard reaction from free asparagine and reducing sugars. The major sources of dietary acrylamide are potato products, processed cereals and coffee. To optimise and validate an analytical method for determining acrylamide in coffee by liquid chromatography and tandem mass spectrometry analysis (LC/MS/MS) using SPE clean-up. Analytical separation of acrylamide from roasted coffee was performed by liquid chromatography using a Hypercarb column followed by LC/MS/MS analysis, with 2,3,3-d3 acrylamide as an internal standard. The method was based on two purification steps: the first with hexane and Carrez solutions in order to remove of fat and to precipitate proteins, respectively; and the second with a solid-phase extraction (SPE) column which proved to be efficient in the elimination of the main chromatographic interferences. Limit of quantification (LOQ) for measuring acrylamide in coffee was 50 microg/kg. The described method demonstrates satisfactory precision (RSD = 2.5%), repeatability (RSD = 9.2%) and accuracy (mean recovery - 97.4%). Our results confirm that LC-MS/MS with SPE clean-up is selective and suitable for determination of acrylamide in coffee. Indeed, this method meets the criteria of EU Commission Recommendations (No. 2007/331/EC and No. 2010/307/EU), on the monitoring of acrylamide levels in food.
Wang, Jixia; Kong, Song; Yan, Jingyu; Jin, Gaowa; Guo, Zhimou; Shen, Aijin; Xu, Junyan; Zhang, Xiuli; Zou, Lijuan; Liang, Xinmiao
2014-06-01
Peptide drugs play a critical role in therapeutic treatment. However, as the complexity of plasma, determination of peptide drugs using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a daunting task. To solve this problem, hydrophilic interaction liquid chromatography-solid phase extraction (HILIC-SPE) directly combined with protein precipitation (PPT) was developed for the selective extraction of triptorelin from plasma. The extracts were analyzed by reversed-phase liquid chromatography (RPLC). Proteins, phospholipids and highly polar interferences could be removed from plasma by the efficient combination of PPT, HILIC-SPE and RPLC-MS/MS. This method was evaluated by matrix effect, recovery and process efficiency at different concentration levels (50, 500 and 5,000 ng/mL) of triptorelin. Furthermore, the performance of HILIC-SPE was compared with that of reversed-phase C18 SPE and hydrophilic lipophilic balance (Oasis HLB) SPE. Among them, HILIC-SPE provided the minimum matrix effect (ranging from 96.02% to 103.41%), the maximum recovery (ranging from 80.68% to 90.54%) and the satisfactory process efficiency (ranging from 82.83% to 92.95%). The validated method was successfully applied to determine triptorelin in rat plasma. Copyright © 2014 Elsevier B.V. All rights reserved.
[Simultaneous determination of pesticide residues in agricultural products by LC-MS/MS].
Watanabe, Minae; Ueno, Eiji; Inoue, Tomomi; Ohno, Haruka; Ikai, Yoshitomo; Morishita, Toshio; Oshima, Harumi; Hayashi, Rumiko
2013-01-01
A method for the simultaneous determination of multiple pesticide residues in agricultural products was developed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample was extracted with acetonitrile. Co-extractives were removed by GPC/graphitized carbon column SPE, and silica gel/PSA cartridge column SPE. Pesticides in the test solution were determined by LC-MS/MS using scheduled MRM. Recoveries of 124 pesticides from spinach, brown rice, soybean, orange and tomato were tested at the level of 0.1 µg/g, and those of 121 pesticides ranged from 70 to 120% (RSD≤15%). Pesticide residues in 239 agricultural products were investigated by this method, and residues of 49 pesticides were detected in 98 agricultural products.
Sun, Hanwen; Wang, Fengchi; Ai, Lianfeng; Guo, Chunhai; Chen, Ruichun
2009-01-01
A sensitive method based on solid-phase extraction-liquid chromatography-tandem mass spectrometry interfaced with electrospray ionization (SPE-LC-MS/MS-ESI) was developed for the simultaneous determination of 8 banned nitroimidazole (NOZ) drugs including metronidazole (MNZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole, ornidazole, secnidazole, metronidazole-OH (MNZOH, the metabolite of MNZ), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the metabolite of RNZ and DMZ) in natural casings. After extraction with ethyl acetate and evaporation, the NOZs were reconstituted in ethyl acetate and purified on a strong cation-exchange SPE column, and then LC/MS/MS analysis was performed by positive ESI applying multiple reaction monitoring of 2 transition reactions for each compound. The method was validated according to the European Union requirements (Commission Decision 2002/657/EC). Specificity, linearity, decision limit (CCalpha), detection capability (CCbeta), accuracy, and precision were determined. Average recoveries of the 8 NOZs from natural animal casing fortified at 3 levels (0.1, 0.5, and 1 microg/kg) ranged from 87.3 to 116.5%. The calculated CCalpha for NOZs ranged from 0.029 to 0.049 microg/kg, and CCbeta ranged from 0.049 to 0.083 microg/kg. Repeatability was in the range of 3.35-10.1%, and within-laboratory reproducibility was <10.3%.
Tagiri-Endo, Misako; Suzuki, Shigeru; Nakamura, Tomoyuki; Hatakeyama, Takashi; Kawamukai, Kazuo
2009-02-01
A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 microl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01-0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.
Robandt, P V; Klette, K L; Sibum, M
2009-10-01
An automated solid-phase extraction coupled with liquid chromatography and tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of 11-nor-Delta(9)-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in human urine specimens was developed. The method was linear (R(2) = 0.9986) to 1000 ng/mL with no carryover evidenced at 2000 ng/mL. Limits of quantification and detection were found to be 2 ng/mL. Interrun precision was evaluated at the 15 ng/mL level over nine batches spanning 15 days (n = 45). The coefficient of variation (%CV) was found to be 5.5% over the course of the validation. Intrarun precision of a 15 ng/mL control (n = 5) ranged from 0.58% CV to 7.4% CV for the same set of analytical batches. Interference was tested using (+/-)-11-hydroxy-Delta(9)-tetrahydrocannabinol, cannabidiol, (-)-Delta(8)-tetrahydrocannabinol, and cannabinol. One hundred and nineteen specimens previously found to contain THC-COOH by a previously validated gas chromatographic mass spectrometry (GC-MS) procedure were compared to the SPE-LC-MS-MS method. Excellent agreement was found (R(2) = 0.9925) for the parallel comparison study. The automated SPE procedure eliminates the human factors of specimen handling, extraction, and derivatization, thereby reducing labor costs and rework resulting from human error or technique issues. Additionally, method runtime is greatly reduced (e.g., during parallel studies the SPE-LC-MS-MS instrument was often finished with analysis by the time the technician finished the offline SPE and derivatization procedure prior to the GC-MS analysis).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castillo, M.; Alonso, M.C.; Riu, J.
1999-04-15
This paper presents a generic protocol for the determination of polar, ionic, and highly water soluble organic pollutants on untreated industrial wastewaters involving the use of two different solid-phase extraction (SPE) methodologies followed by liquid chromatography-mass spectrometry (LC-MS). Untreated industrial wastewaters might contain natural and synthetic dissolved organic compounds with total organic carbon (TOC) values varying between 100 and 3000 mg/L. All polar, ionic and highly water soluble compounds comprising more than 95% of the organic content and with major contribution to the total toxicity of the sample cannot be analyzed by conventional gas chromatography-mass spectrometry (GC-MS), and LC-MS ismore » a good alternative. In this work two extraction procedures were used to obtain fractionated extracts of the nonionic polar compounds: a polymeric Isolute ENV + SPE cartridge for the preconcentration of anionic analytes and a sequential solid-phase extraction (SSPE) method percolating the samples first in octadecylsilica cartridge in series with the polymeric Lichrolut EN cartridge. Average recoveries ranging from 72% to 103% were obtained for a variety of 23 different analytes. Determination of nonionic pollutants was accomplished by reverse-phase liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), while anionic compounds were analyzed by ion pair chromatography-electrospray-mass spectrometry (IP-ESI-MS) and LC-ESI-MS. This protocol was applied to a pilot survey of textile and tannery wastewaters leading to the identification and quantification of 33 organic pollutants.« less
Turrell, Elizabeth; Stobo, Lesley; Lacaze, Jean-Pierre; Piletsky, Sergey; Piletska, Elena
2008-01-01
The combination of hydrophilic interaction liquid chromatography (HILIC) and liquid chromatography/mass spectrometry (LC/MS) for the determination of paralytic shellfish poisoning (PSP) toxins has been proposed for use in routine monitoring of shellfish. In this study, methods for the detection of multiple PSP toxins [saxitoxin (STX), neosaxitoxin (NEO), decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNEO), gonyautoxins 1-5 (GTX1, GTX2, GTX3, GTX4, GTX5), decarbamoyl gonyautoxins (dcGTX2 and dcGTX3), and the N-sulfocarbamoyl C toxins (C1 and C2)] were optimized using single (MS) and triple quadrupole (MS/MS) instruments. Chromatographic separation of the toxins was achieved by using a TSK-gel Amide-80 analytical column, although superior chromatography was observed through application of a ZIC-HILIC column. Preparative procedures used to clean up shellfish extracts and concentrate PSP toxins prior to analysis were investigated. The capacity of computationally designed polymeric (CDP) materials and HILIC solid-phase extraction (SPE) cartridges to retain highly polar PSP toxins was explored. Three CDP materials and 2 HILIC cartridges were assessed for the extraction of PSP toxins from aqueous solution. Screening of the CDPs showed that all tested polymers adsorbed PSP toxins. A variety of elution procedures were examined, with dilute 0.01% acetic acid providing optimum recovery from a CDP based on 2-(trifluoromethyl)acrylic acid as the monomer. ZIC-HILIC SPE cartridges were superior to the PolyLC equivalent, with recoveries ranging from 70 to 112% (ZIC-HILIC) and 0 to 90% (PolyLC) depending on the PSP toxin. It is proposed that optimized SPE and HILIC-MS methods can be applied for the quantitative determination of PSP toxins in shellfish.
Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon
2016-07-01
A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.
Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.
Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun
2018-05-14
To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.
Kubo, Takuya; Kuroda, Kenta; Tominaga, Yuichi; Naito, Toyohiro; Sueyoshi, Kenji; Hosoya, Ken; Otsuka, Koji
2014-02-01
We report an effective and a quantitative analysis method for one of pharmaceuticals, sulpiride, in river water by online solid phase extraction (SPE) connected with liquid chromatography-mass spectrometry (LC-MS) using a molecularly imprinted polymer as a preconcentration medium. The polymer prepared with a pseudo template molecule showed the selective retention ability based on the interval recognition of functional groups in sulpiride. Also, the imprinted polymer provided an effective concentration of a trace level of sulpiride in offline SPE with dual washing processes using water and acetonitrile, although another imprinted polymer prepared by an authentic method using sulpiride and methacrylic acid as a template and a functional monomer, respectively, showed the selective adsorption only in organic solvents. Furthermore, we employed the imprinted polymer as the preconcentration column of online SPE-LC-MS and the results supposed that the proposed system allowed the quantitative analysis of sulpiride with high sensitivity and recovery (10ng/L at 96%). Additionally, the determination of sulpiride in real river water without an additional spiking was effectively achieved by the system. Copyright © 2013 Elsevier B.V. All rights reserved.
Glufosinate ammonium clean-up procedure from water samples using SPE
NASA Astrophysics Data System (ADS)
Tayeb M., A.; Ismail B., S.; Mardiana-Jansar, K.; Ta, Goh Choo; Agustar, Hani Kartini
2015-09-01
For the determination of glufosinate ammonium residue in soil and water samples, different solid phase extraction (SPE) sorbent efficiency was studied. Four different SPE sorbents i.e.: CROMABOND PS-H+, CROMABOND PS-OH-, ISOLUTE ENV+, Water Sep-Pak and OASIS HLB were used. Sample clean-up performance was evaluated using high performance liquid chromatography (Agilent 1220 infinity LC) with fluorescence detector. Detection of FMO-derivatives was done at λ ex = 260 nm and λ em= 310 nm. OASIS HLB column was the most suitable for the clean-up in view of the overall feasibility of the analysis.
Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An
2007-08-17
By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.
Zheng, Shu-Jian; Wang, Ya-Lan; Liu, Ping; Zhang, Zheng; Yu, Lei; Yuan, Bi-Feng; Feng, Yu-Qi
2017-12-15
In this study, we developed a strategy for profiling of thiols and aldehydes in beer samples by stable isotope labeling-solid phase extraction-liquid chromatography-double precursor ion scan/double neutral loss scan-mass spectrometry analysis (SIL-SPE-LC-DPIS/DNLS-MS). A pair of isotope reagents (ω-bromoacetonylquinolinium bromide, BQB; ω-bromoacetonylquinolinium-d 7 bromide, BQB-d 7 ) were used to label thiols; while for the aldehydes, a pair of isotope reagents (4-(2-(trimethylammonio) ethoxy) benzenaminium halide, 4-APC; 4-(2-(trimethylammonio) ethoxy) benzenaminium halide-d 4 , 4-APC-d 4 ) were used. The labeled thiols and aldehydes were extracted and purified with solid-phase extraction, respectively, followed by LC-MS analysis. Using the proposed SIL-SPE-LC-DPIS/DNLS-MS methods, 76 thiol and 25 aldehyde candidates were found in beer. Furthermore, we established SIL-SPE-LC-MRM-MS methods for the relative quantitation of thiols and aldehydes in different beer samples. The results showed that the contents of thiols and aldehydes are closely related to the brands and origins of beers. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pedersen, S N; Lindholst, C
1999-12-09
Extraction methods were developed for quantification of the xenoestrogens 4-tert.-octylphenol (tOP) and bisphenol A (BPA) in water and in liver and muscle tissue from the rainbow trout (Oncorhynchus mykiss). The extraction of tOP and BPA from tissue samples was carried out using microwave-assisted solvent extraction (MASE) followed by solid-phase extraction (SPE). Water samples were extracted using only SPE. For the quantification of tOP and BPA, liquid chromatography mass spectrometry (LC-MS) equipped with an atmospheric pressure chemical ionisation interface (APCI) was applied. The combined methods for tissue extraction allow the use of small sample amounts of liver or muscle (typically 1 g), low volumes of solvent (20 ml), and short extraction times (25 min). Limits of quantification of tOP in tissue samples were found to be approximately 10 ng/g in muscle and 50 ng/g in liver (both based on 1 g of fresh tissue). The corresponding values for BPA were approximately 50 ng/g in both muscle and liver tissue. In water, the limit of quantification for tOP and BPA was approximately 0.1 microg/l (based on 100 ml sample size).
Chen, Zhidan; Coy, Stephen L; Pannkuk, Evan L; Laiakis, Evagelia C; Fornace, Albert J; Vouros, Paul
2018-05-07
High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. Graphical Abstract.
NASA Astrophysics Data System (ADS)
Chen, Zhidan; Coy, Stephen L.; Pannkuk, Evan L.; Laiakis, Evagelia C.; Fornace, Albert J.; Vouros, Paul
2018-05-01
High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. [Figure not available: see fulltext.
Kirschbaum, Katrin M; Grellner, Wolfgang; Rochholz, Gertrud; Musshoff, Frank; Madea, Burkhard
2011-03-01
Quaternary ammonium compounds pose an analytical challenge. Mebezonium, a muscle-relaxing agent contained in veterinary euthanasia solution T61, was analyzed in body fluids, organs, and injection sites of a veterinarian by liquid chromatography-tandem mass spectrometry (LC-MS-MS) method. Additionally, embutramide and tetracaine, which are two other active ingredients contained in T61, methadone, xylazine, and analgesics were detected by LC-MS-MS and high-performance liquid chromatography-ultraviolet detection methods. For detection of mebezonium a solid-phase extraction (SPE) combined with ionpairing reagent heptafluorobutyric acid was developed. Separation was achieved on Phenomenex Synergi Hydro RP C(18) column combined with ammonium formate buffer and acetonitrile (pH 3.5). To enrich other drugs, liquid-liquid extraction procedures were used. Most of these drugs were separated on a Restek Allure PFP Propyl column using the mentioned mobile phase. Mebezonium and embutramide were detected in femoral vein serum in concentrations of 10.9 and 2.0 mg/L, respectively. The concentration of xylazine and methadone in serum was 2.0 and 0.4 mg/L, respectively. The LC-MS-MS method with SPE combined with an ion-pairing reagent allowed the quantitation of mebezonium. Methadone was detected in toxic concentrations and was, in combination with xylazine and T61, considered to be the cause of death.
Rugged LC-MS/MS survey analysis for acrylamide in foods.
Roach, John A G; Andrzejewski, Denis; Gay, Martha L; Nortrup, David; Musser, Steven M
2003-12-17
The described liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of acrylamide in food entails aqueous room temperature extraction, SPE cleanup, and analysis by LC-MS/MS. The method is applicable to a wide variety of foods. [(13)C(3)]acrylamide is the internal standard. The limit of quantitation is 10 ppb (microg/kg). Data were obtained in duplicate from >450 products representing >35 different food types. The variability in analyte levels in certain food types suggests that it may be possible to reduce acrylamide levels in those foods.
Quantification of tylosin and tylosin antibiotic resistance genes in cattle waste
USDA-ARS?s Scientific Manuscript database
Presented is the development of a solid phase extraction (SPE) procedure and a liquid chromatography-mass spectrometry (LC-MS/MS) method for quantifying tylosin in cattle waste samples. Tylosin is a macrolide antibiotic found naturally as a fermentation product of Streptomyces fradiae and is mainly ...
The emphasis of this research project was to develop, and optimize, a solid-phase extraction (SPE) method and high performance liquid chromatography-electrospray ionization- mass spectrometry (LC-MS/MS) method, such that a linkage between the detection of endocrine active pharma...
Bassarab, P; Williams, D; Dean, J R; Ludkin, E; Perry, J J
2011-02-04
A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120-270ng/l. Copyright © 2010 Elsevier B.V. All rights reserved.
Chu, Wenhai; Gao, Naiyun; Yin, Daqiang; Krasner, Stuart W; Templeton, Michael R
2012-04-27
The haloacetamides (HAcAms) are disinfection by-products (DBPs) in drinking water which are currently receiving increased scientific attention due to their elevated toxicity relative to regulated disinfection by-products. A simultaneous determination method of 13 HAcAms, combining solid-phase extraction (SPE) enrichment, liquid chromatographic (LC) separation, and triple quadrupole mass spectrometry (tqMS) detection with atmospheric pressure chemical ionization (APCI) using selective reaction monitoring in positive mode, was developed to measure HAcAms, including chlorinated, brominated, and iodinated analogs. Ammonium chloride and Oasis HLB were selected as the dechlorinating reagent and polymeric SPE sorbent of HAcAm samples. The used tqMS apparatus showed higher sensitivity for the studied HAcAms in the APCI mode than electrospray ionization. 13 HAcAms were separated by LC in 9.0 min, and the detection limits ranged from 7.6 to 19.7 ng/L. The SPE-LC/tqMS method was successfully applied to quantify 13 HAcAms in drinking water samples for the first time, and first indentified tribromoacetamide and chloroiodoacetamide as DBPs in drinking water. Copyright © 2012 Elsevier B.V. All rights reserved.
Heller, David N; Nochetto, Cristina B; Rummel, Nathan G; Thomas, Michael H
2006-07-26
A method was developed for detection of a variety of polar drug residues in eggs via liquid chromatography/tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI). A total of twenty-nine target analytes from four drug classes-sulfonamides, tetracyclines, fluoroquinolones, and beta-lactams-were extracted from eggs using a hydrophilic-lipophilic balance polymer solid-phase extraction (SPE) cartridge. The extraction technique was developed for use at a target concentration of 100 ng/mL (ppb), and it was applied to eggs containing incurred residues from dosed laying hens. The ESI source was tuned using a single, generic set of tuning parameters, and analytes were separated with a phenyl-bonded silica cartridge column using an LC gradient. In a related study, residues of beta-lactam drugs were not found by LC/MS/MS in eggs from hens dosed orally with beta-lactam drugs. LC/MS/MS performance was evaluated on two generations of ion trap mass spectrometers, and key operational parameters were identified for each instrument. The ion trap acquisition methods could be set up for screening (a single product ion) or confirmation (multiple product ions). The lower limit of detection for screening purposes was 10-50 ppb (sulfonamides), 10-20 ppb (fluoroquinolones), and 10-50 ppb (tetracyclines), depending on the drug, instrument, and acquisition method. Development of this method demonstrates the feasibility of generic SPE, LC, and MS conditions for multiclass LC/MS residue screening.
Identification of a new degradation product of the antifouling agent Irgarol 1051 in natural samples
Ferrer, I.; Barcelo, D.
2001-01-01
A main degradation product of Irgarol [2-(methylthio)-4-(tert-butylamino)-6-(cyclopropylamino)-s-triazine], one of the most widely used compounds in antifouling paints, was detected at trace levels in seawater and sediment samples collected from several marinas on the Mediterranean coast. This degradation product was identified as 2-methylthio-4-tert-butylamino-s-triazine. The unequivocal identification of this compound in seawater samples was carried out by solid-phase extraction (SPE) coupled on-line with liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS). SPE was carried out by passing 150 ml of seawater sample through a cartridge containing a polymeric phase (PLRP-s), with recoveries ranging from 92 to 108% (n=5). Using LC-MS detection in positive ion mode, useful structural information was obtained by increasing the fragmentor voltage, thus permitting the unequivocal identification of this compound in natural samples. Method detection limits were in the range of 0.002 to 0.005 ??g/l. Overall, the combination of on-line SPE and LC-APCI-MS represents an important advance in environmental analysis of herbicide degradation products in seawater, since it demonstrates that trace amounts of new polar metabolites may be determined rapidly. This paper reports the LC-MS identification of the main degradation product of Irgarol in seawater and sediment samples. ?? 2001 Elsevier Science B.V. All rights reserved.
Mijangos, Leire; Ziarrusta, Haizea; Olivares, Maitane; Zuloaga, Olatz; Möder, Monika; Etxebarria, Nestor; Prieto, Ailette
2018-01-01
A new procedure using polyethersulfone (PES) microextraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was developed in this work for the simultaneous determination of 41 multiclass priority and emerging organic pollutants including herbicides, hormones, personal care products, and pharmaceuticals, among others, in seawater, wastewater treatment plant (WWTP) effluents, and estuary samples. The optimization of the analysis included two different chromatographic columns and different variables (polarity, fragmentor voltage, collision energy, and collision cell accelerator) of the mass spectrometer. In the case of PES extraction, ion strength of the water, pH, addition of EDTA, and the amount of the polymeric material were thoroughly investigated. The developed procedure was compared with a previously validated one based on a standard solid-phase extraction (SPE). In contrast to the SPE protocol, the PES method allowed a cost-efficient extraction of complex aqueous samples with lower matrix effect from 120 mL of water sample. Satisfactory and comparable apparent recovery values (80-119 and 70-131%) and method quantification limits (MQLs, 0.4-26 and 0.2-23 ng/L) were obtained for PES and SPE procedures, respectively, regardless of the matrix. Repeatability values lower than 27% were obtained. Finally, the developed methods were applied to the analysis of real samples from the Basque Country and irbesartan, valsartan, acesulfame, and sucralose were the analytes most often detected at the highest concentrations (51-1096 ng/L). Graphical abstract Forty-one multiclass pollutant determination in environmental waters by means of PES/SPE-LC-MS/MS.
Zhang, Jie; Bai, Ruoshi; Zhou, Zhaojuan; Liu, Xingyu; Zhou, Jun
2017-04-01
A fully automated analytical method was developed and validated by this present study. The method was based on two-dimensional (2D) online solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) to determine nine aromatic amines (AAs) in mainstream smoke (MSS) simultaneously. As a part of validation process, AAs yields for 16 top-selling commercial cigarettes from China market were evaluated by the developed method under both Health Canada Intensive (HCI) and ISO machine smoking regimes. The gas phase of MSS was trapped by 25 mL 0.6 M hydrochloric acid solution, while the particulate phase was collected on a glass fiber filter. Then, the glass fiber pad was extracted with hydrochloric acid solution in an ultrasonic bath. The extract was analyzed with 2D online SPE-LC-MS/MS. In order to minimize the matrix effects of sample on each analyte, two cartridges with different extraction mechanisms were utilized to cleanup disturbances of different polarity, which were performed by the 2D SPE. A phenyl-hexyl analytical column was used to achieve a chromatographic separation. Under the optimized conditions, the isomers of p-toluidine, m-toluidine and o-toluidine, 3-aminobiphenyl and 4-aminobiphenyl, and 1-naphthylamine and 2-naphthylamine were baseline separated with good peak shapes for the first time. The limits of detection for nine AAs ranged from 0.03 to 0.24 ng cig -1 . The recovery of the measurement of nine AAs was from 84.82 to 118.47%. The intra-day and inter-day precisions of nine AAs were less than 10 and 16%, respectively. Compared with ISO machine smoking regime, the AAs yields in MSS were 1.17 to 3.41 times higher under HCI machine smoking regime. Graphical abstract New method using online SPE-LC/MS/MS for analysis of aromatic amines in mainstream cigarette smoke.
Fagerquist, Clifton K; Lightfield, Alan R; Lehotay, Steven J
2005-03-01
A simple, rapid, rugged, sensitive, and specific method for the confirmation and quantitation of 10 beta-lactam antibiotics in fortified and incurred bovine kidney tissue has been developed. The method uses a simple solvent extraction, dispersive solid-phase extraction (dispersive-SPE) cleanup, and liquid chromatography-tandem mass spectrometry (LC/MS/MS) for confirmation and quantitation. Dispersive-SPE greatly simplifies and accelerates sample cleanup and improves overall recoveries compared with conventional SPE cleanup. The beta-lactam antibiotics tested were as follows: deacetylcephapirin (an antimicrobial metabolite of cephapirin), amoxicillin, desfuroylceftiofur cysteine disulfide (DCCD, an antimicrobial metabolite of ceftiofur), ampicillin, cefazolin, penicillin G, oxacillin, cloxacillin, naficillin, and dicloxacillin. Average recoveries of fortified samples were 70% or better for all beta-lactams except DCCD, which had an average recovery of 58%. The LC/MS/MS method was able to demonstrate quantitative recoveries at established tolerance levels and provide confirmatory data for unambiguous analyte identification. The method was also tested on 30 incurred bovine kidney samples obtained from the USDA Food Safety and Inspection Service, which had previously tested the samples using the approved semiquantitative microbial assay. The results from the quantitative LC/MS/MS analysis were in general agreement with the microbial assay for 23 samples although the LC/MS/MS method was superior in that it could specifically identify which beta-lactam was present and quantitate its concentration, whereas the microbial assay could only identify the type of beta-lactam present and report a concentration with respect to the microbial inhibition of a penicillin G standard. In addition, for 6 of the 23 samples, LC/MS/MS analysis detected a penicillin and a cephalosporin beta-lactam, whereas the microbial assay detected only a penicillin beta-lactam. For samples that do not fall into the "general agreement" category, the most serious discrepancy involves two samples where the LC/MS/MS method detected a violative level of a cephalosporin beta-lactam (deacetylcephapirin) in the first sample and a possibly violative level of desfuroylceftiofur in the second, whereas the microbial assay identified the two samples as having only violative levels of a penicillin beta-lactam.
Yen, Hung-Kai; Lin, Tsair-Fuh; Liao, Pao-Chi
2011-08-01
A solid-phase extraction (SPE)-liquid chromatography (LC)-mass spectrometry (MS) method was developed to concentrate and detect nine cyanotoxins simultaneously, including six microcystins (MCs) congeners, nodularin (NOD), anatoxin-a (ATX) and cylindrospermopsin (CYN), in pure and natural waters. A dual cartridge SPE assembly was tested for the operating parameters of cyanotoxin extraction. A surrogate standard (SS), 1,9-diaminononane, was spiked in all the samples before the SPE extraction, and an internal standard (IS), 2,3,5-trimethylphenyl methyl carbamate, was spiked before LC/MS analysis. The method detection limit (MDL) was 2-100 ng/L for nine cyanotoxins in pure water and was increased by a factor of three to ten in a more complicated water matrix. The recoveries based on SS were between 83 and 104%, while those based on IS were 80-120%. The developed method was successfully employed in analyzing 33 water samples collected from eutrophic lakes, water treatment plants and distribution taps. MCs, NOD, and CYN were detected in the reservoir water, with concentrations as high as 36 μg/L. In addition, for the first time in Taiwan's tap water, CYN was detected at concentrations as high as 8.6 μg/L. Quality control data for the field samples shows that the analytical scheme developed is appropriate for monitoring cyanotoxins. Copyright © 2011 Elsevier Ltd. All rights reserved.
Murakami, Tomonori; Kawasaki, Takao; Takemura, Akira; Fukutsu, Naoto; Kishi, Naoyuki; Kusu, Fumiyo
2008-10-24
Rapid and unambiguous identification of three degradation products (DP-1, DP-2 and DP-3) found in heat-stressed loxoprofen sodium adhesive tapes (Loxonin tapes) was achieved by LC-MS and dynamic pressurized liquid extraction (PLE)-solid-phase extraction (SPE) coupled to LC-NMR without complicated isolation or purification processes. The molecular formulae of the degradation products were determined by accurate mass measurements and product ion analyses and on-line hydrogen/deuterium (H/D) exchange experiments provided information about changes in the degradation of loxoprofen. To compensate for the low sensitivity of NMR, on-line dynamic PLE-SPE was employed and higher concentrations of degradation products trapped on the SPE column were afforded in a shorter time than they would be in such time-consuming sample preparations as pre-concentration after extraction. The loop-storage procedure was used in the LC-NMR analysis to allow the acquisition of the (1)H spectra of the three degradation products in one chromatographic run without affecting the peak separation and to avoid the carry-over of previously eluted DP-1 of high concentration by washing the NMR detection cell prior to the measurement of the DP-2 spectrum. Based on the resulting (1)H NMR spectra in combination with the MS results, DP-1 was successfully identified as an oxidation product having an oxodicarboxylic acid structure formed by the cleavage of the cyclopentanone ring of loxoprofen, DP-2 as a cyclopentanone ring-hydroxylated loxoprofen and DP-3 as a loxoprofen l-menthol ester.
Seo, Miyeong; Kim, Byungjoo; Baek, Song-Yee
2015-07-01
Patulin, a mycotoxin produced by several molds in fruits, has been frequently detected in apple products. Therefore, regulatory bodies have established recommended maximum permitted patulin concentrations for each type of apple product. Although several analytical methods have been adopted to determine patulin in food, quality control of patulin analysis is not easy, as reliable certified reference materials (CRMs) are not available. In this study, as a part of a project for developing CRMs for patulin analysis, we developed isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC/MS/MS) as a higher-order reference method for the accurate value-assignment of CRMs. (13)C7-patulin was used as internal standard. Samples were extracted with ethyl acetate to improve recovery. For further sample cleanup with solid-phase extraction (SPE), the HLB SPE cartridge was chosen after comparing with several other types of SPE cartridges. High-performance liquid chromatography was performed on a multimode column for proper retention and separation of highly polar and water-soluble patulin from sample interferences. Sample extracts were analyzed by LC/MS/MS with electrospray ionization in negative ion mode with selected reaction monitoring of patulin and (13)C7-patulin at m/z 153→m/z 109 and m/z 160→m/z 115, respectively. The validity of the method was tested by measuring gravimetrically fortified samples of various apple products. In addition, the repeatability and the reproducibility of the method were tested to evaluate the performance of the method. The method was shown to provide accurate measurements in the 3-40 μg/kg range with a relative expanded uncertainty of around 1%.
Robandt, Paul P; Reda, Louis J; Klette, Kevin L
2008-10-01
A fully automated system utilizing a liquid handler and an online solid-phase extraction (SPE) device coupled with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was designed to process, detect, and quantify benzoylecgonine (BZE), meta-hydroxybenzoylecgonine (m-OH BZE), para-hydroxybenzoylecgonine (p-OH BZE), and norbenzoylecgonine (nor-BZE) metabolites in human urine. The method was linear for BZE, m-OH BZE, and p-OH BZE from 1.2 to 10,000 ng/mL with limits of detection (LOD) and quantification (LOQ) of 1.2 ng/mL. Nor-BZE was linear from 5 to 10,000 ng/mL with an LOD and LOQ of 1.2 and 5 ng/mL, respectively. The intrarun precision measured as the coefficient of variation of 10 replicates of a 100 ng/mL control was less than 2.6%, and the interrun precision for 5 replicates of the same control across 8 batches was less than 4.8% for all analytes. No assay interference was noted from controls containing cocaine, cocaethylene, and ecgonine methyl ester. Excellent data concordance (R2 > 0.994) was found for direct comparison of the automated SPE-LC-MS-MS procedure and an existing gas chromatography-MS procedure using 94 human urine samples previously determined to be positive for BZE. The automated specimen handling and SPE procedure, when compared to the traditional extraction schema, eliminates the human factors of specimen handling, processing, extraction, and derivatization, thereby reducing labor costs and rework resulting from batch handling issues, and may reduce the number of fume hoods required in the laboratory.
Hu, Chaofan; Jia, Li; Liu, Qingqing; Zhang, Sheng
2010-07-01
A sensitive, fast and simple method based on magnetic octadecylsilane particles was developed for the extraction of three fat-soluble vitamins followed by capillary LC (CLC) analysis with UV detection. Magnetic octadecylsilane particles were prepared based on three-step reactions including co-precipitation, sol-gel polymerization and alkylation. The characterization of the prepared product was studied by scanning electron microscope and Fourier-transform infrared spectrometry. The particles were used as magnetic SPE adsorbent for the extraction of fat-soluble vitamins in fruit juice-milk beverage. The extraction condition and efficiency of the particles for fat-soluble vitamins were investigated. By coupling magnetic SPE with capillary LC with UV detection, low concentrations of fat-soluble vitamins in fruit juice-milk beverage can be detected without the interference from other substances in the sample matrix.
METHOD 544. DETERMINATION OF MICROCYSTINS AND ...
Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensitivity and ability to speciate the microcystins. This method development task establishes sample preservation techniques, sample concentration and analytical procedures, aqueous and extract holding time criteria and quality control procedures. Draft Method 544 undergone a multi-laboratory verification to ensure other laboratories can implement the method and achieve the quality control measures specified in the method. It is anticipated that Method 544 may be used in UCMR 4 to collect nationwide occurrence data for selected microcystins in drinking water. The purpose of this research project is to develop an accurate and precise analytical method to concentrate and determine selected MCs and nodularin in drinking water.
Rubirola, Adrià; Boleda, Mª Rosa; Galceran, Mª Teresa
2017-04-14
This paper reports the development of a fully multiresidue and automated on-line solid phase extraction (SPE) - liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of 24 priority substances (PS) belonging to different classes (pesticides, hormones or pharmaceuticals) included in the Directive 2013/39/UE and the recent Watch List (Decision 2015/495) in water samples (drinking water, surface water, and effluent wastewaters). LC-MS/MS conditions and on-line SPE parameters such as sorbent type, sample and wash volumes were optimized. The developed method is highly sensitive (limits of detection between 0.1 and 1.4ngL -1 ) and precise (relative standard deviations lower than 8%). As part of the method validation studies, linearity, accuracy and matrix effects were assessed. The main advantage of this method over traditional off-line procedures is the minimization of tedious sample preparation increasing productivity and sample throughput. The optimized method was applied to the analysis of water samples and the results revealed the presence of 16 PS in river water and effluent water of wastewater treatment plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Ma, Zhen; Ge, Liya; Lee, Anna S Y; Yong, Jean Wan Hong; Tan, Swee Ngin; Ong, Eng Shi
2008-03-10
Coconut (Cocos nucifera L.) water, which contains many uncharacterized phytohormones is extensively used as a growth promoting supplement in plant tissue culture. In this paper, a high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of various classes phytohormones, including indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), gibberellic acid (GA), zeatin (Z), N(6)-benzyladenine (BA), alpha-naphthaleneacetic acid (NAA) and 2,4-dichlorophenoxyacetic acid (2,4-D) in young coconut water (CW). The analysis was carried out using a reverse-phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid, pH adjusted to 3.2 with triethylamine (TEA)) modified by methanol, and solute detection made at 265 nm wavelength. The method was validated for specificity, quantification, accuracy and precision. After preconcentration of putative endogenous phytohormones in CW using C(18) solid-phase extraction (SPE) cartridges, the HPLC method was able to screen for putative endogenous phytohormones present in CW. Finally, the identities of the putative phytohormones present in CW were further confirmed using independent liquid chromatography-tandem mass spectrometry (LC-MS/MS) equipped with an electrospray ionization (ESI) interface.
NASA Astrophysics Data System (ADS)
Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali
2013-11-01
In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.
Qu, Lihua; Fan, Yuanjie; Wang, Wenjun; Ma, Kai; Yin, Zheng
2016-09-01
A simple and efficient bioanalytical method for simultaneous determination of phenobarbital (PB), phenytoin (PHT), carbamazepine (CBZ), and its active metabolite carbamazepine 10,11-epoxide (CBZE) in human plasma using online solid phase extraction (SPE)-liquid chromatography (LC) coupled with high resolution mass spectrum (HRMS) under targeted MS/MS (t-MS(2)) analysis mode has been developed. The procedure integrated an automated sample clean-up of human plasma by Oasis®HLB SPE cartridge, a separation by ZORBAX SB-C18 analysis column, and a quantification by Q-Exactive Hybrid Quadrupole-Orbitrap. The total running time was 13min. The lower limit of quantification (LLOQ) of PB, PHT, CBZ, and CBZE were 0.008, 0.008, 0.0016 and 0.0016μgmL(-1) respectively and the linearities were in the range of 0.008-2.500, 0.008-2.500, 0.0016-0.500 and 0.0016-0.500μgmL(-1) respectively. The mean recovery was between 91.82% and 108.27% and the matrix effect was between 93.29% and 102.09%. The relative standard deviations of interday and intraday were less than 6.41%. The method has been successfully applied in therapeutic drug monitoring (TDM) of four Chinese epilepsy patients. This fully automated, simple, sensitive and reliable online-SPE-LC-HRMS/MS method serves well for TDM of PB, PHT, CBZ and CBZE at clinics for either single or combination treatment. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Zheng; Hao, Yan-Hong; Ding, Jun; Xu, Sheng-Nan; Yuan, Bi-Feng; Feng, Yu-Qi
2015-10-16
A newly improved one-pot method, based on "thiol-ene" click chemistry and sol-gel approach in microemulsion system, was developed for the preparation of C8/PO(OH)2-silica hybrid monolithic capillary column. The prepared monolith possesses large specific surface area, narrow mesopore size distribution and high column efficiency. The monolithic column was demonstrated to have cation exchange/reversed-phase (CX/RP) mixed-mode retention for analytes on nano-liquid chromatography (nano-LC). On the basis of the developed nano-LC system with MS detector coupled to pipette tip solid phase extraction (PT-SPE) and derivatization process, we then realized simultaneous determination of 10 gibberellins (GAs) with low limits of detection (LODs, 0.003-0.025 ng/mL). Furthermore, 6 endogenous GAs in only 5mg rice leaves (fresh weight) were successfully detected and quantified. The developed PT-SPE-nano-LC-MS strategy may offer promising applications in the determination of low abundant bioactive molecules from complex matrix. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Hok, S; Alcaraz, A
Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less
Lawal, Abubakar; Wong, Richard Chee Seng; Tan, Guan Huat; Abdulra'uf, Lukman Bola; Alsharif, Ali Mohamed Ali
2018-04-21
Fruits and vegetables constitute a major type of food consumed daily apart from whole grains. Unfortunately, the residual deposits of pesticides in these products are becoming a major health concern for human consumption. Consequently, the outcome of the long-term accumulation of pesticide residues has posed many health issues to both humans and animals in the environment. However, the residues have previously been determined using conventionally known techniques, which include liquid-liquid extraction, solid-phase extraction (SPE) and the recently used liquid-phase microextraction techniques. Despite the positive technological effects of these methods, their limitations include; time-consuming, operational difficulty, use of toxic organic solvents, low selective property and expensive extraction setups, with shorter lifespan of instrumental performances. Thus, the potential and maximum use of these methods for pesticides residue determination has resulted in the urgent need for better techniques that will overcome the highlighted drawbacks. Alternatively, attention has been drawn recently towards the use of quick, easy, cheap, effective, rugged and safe technique (QuEChERS) coupled with dispersive solid-phase extraction (dSPE) to overcome the setback challenges experienced by the previous technologies. Conclusively, the reviewed QuEChERS-dSPE techniques and the recent cleanup modifications justifiably prove to be reliable for routine determination and monitoring the concentration levels of pesticide residues using advanced instruments such as high-performance liquid chromatography, liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry.
Dumasia, M C; Teale, P
2005-01-04
Millophyline-V, (etamiphylline camsylate) was administered intramuscularly to two racing greyhounds at a dose of 10 mg kg(-1). Unhydrolysed pre- and post-administration urine samples were extracted using mixed mode solid phase extraction (SPE) cartridges, the basic isolates derivatised as trimethylsilyl ethers and analysed by positive ion electron ionisation gas chromatography-mass spectrometry (GC/EI+/MS). The parent drug and one metabolite, N-desethyletamiphylline, were detected in urine for up to 72 h. For semi-quantification, urine samples were extracted on-line using a Prospekt sample handler. The analytes retained on the C2 SPE cartridge were eluted by the mobile phase directly on to the analytical high performance liquid chromatography column and analysed by positive ion atmospheric pressure chemical ionisation (LC/APCI+) MS in the multiple selective-ion recording mode. A major peak containing both ions (m/z) 280 and (m/z) 252 was observed. Full scan LC/APCI+/MS of the unknown indicated that the ion at (m/z) 280 was formed by the loss of an oxygen atom [MH+ -->(MH+-O)]. Samples were analysed by positive ion electrospray ionisation LC/MS on two different instruments and the unknown compound was identified as an N-oxide of the tert. nitrogen atom of the 2-(diethylamino)ethyl substituent on N7 of the theophylline nucleus. This compound has not been reported previously either as an in vivo or in vitro metabolite of etamiphylline in any species. Thermal decomposition of the N-oxide could lead to an increase the detection period of the parent drug during routine GC/MS screening of post-competition greyhound urine samples.
Yao, Chang-Liang; Yang, Wen-Zhi; Si, Wei; Shen, Yao; Zhang, Nai-Xia; Chen, Hua-Li; Pan, Hui-Qin; Yang, Min; Wu, Wan-Ying; Guo, De-An
2017-03-31
Targeted identification of potentially bioactive molecules from herbal medicines is often stymied by the insufficient chromatographic separation, ubiquitous matrix interference, and pervasive isomerism. An enhanced targeted identification strategy is presented and validated by the selective identification of flavonoid O-glycosides (FOGs) from Carthamus tinctorius. It consists of four steps: (i) enhanced separation and detection by offline two-dimensional liquid chromatography/LTQ-Orbitrap MS (offline 2D-LC/LTQ-Orbitrap MS) using collision-induced dissociation (CID) and high-energy C-trap dissociation (HCD); (ii) improved identification of the major aglycones by acid hydrolysis and LC-SPE-NMR; (iii) simplified spectral elucidation by high-resolution diagnostic product ions/neutral loss filtering; and (iv) more convincing structural identification by matching an in-house library. An offline 2D-LC system configuring an Acchrom XAmide column and a BEH Shield RP-18 UPLC ® column enabled much better separation of the easily co-eluting components. Combined use of CID and HCD could produce complementary fragmentation information. The intensity ratios of the aglycone ion species ([Y 0 -H] - /Y 0 - and [Y 0 -2H] - /Y 0 - ) in the HCD-MS 2 spectra were found diagnostic for discriminating the aglycone subtypes and characterizing the glycosylation patterns. Five aglycone structures (kaempferol, 6-hydroxykaempferol, 6-methoxykaempferol, carthamidin, and isocarthamidin) were identified based on the 1 H-NMR data recorded by LC-SPE-NMR. Of the 107 characterized flavonoids, 80 FOGs were first reported from C. tinctorius. Unknown aglycones, pentose, and novel acyl substituents were discovered. A new compound thereof was isolated and fully identified, which could partially validate the MS-oriented identification. This integral strategy can improve the potency, efficiency, and accuracy in the detection of new compounds from medicinal herbs and other natural sources. Copyright © 2017 Elsevier B.V. All rights reserved.
Rocío-Bautista, Priscilla; Pino, Verónica; Pasán, Jorge; López-Hernández, Irene; Ayala, Juan H; Ruiz-Pérez, Catalina; Afonso, Ana M
2018-03-01
Five metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5(Zn), MIL-53(Al), UiO-64 and MOF-74(Zn) are synthesized, characterized, and utilized in a miniaturized solid-phase extraction method under dispersive mode (D-µSPE) for the determination of six pollutants of different nature, including one polycyclic aromatic hydrocarbon, two hormones, two drugs, and one disinfectant, from environmental waters (tap water and wastewater). A discussion of possible interactions justifying the partitioning of target analytes to the MOFs is included, considering not only the analytes' physicochemical characteristics but also those of MOFs: metal nature, structural environment of MOF pores, pore size and pore aperture widths, among others. MIL-53(Al) is selected for its versatility and high extraction efficiency for the target compounds. The D-µSPE method using MIL-53(Al) is optimized and used in combination with high-performance liquid chromatography (HPLC) with diode array detector (DAD) or liquid-chromatography with time-of-flight mass spectrometric detector (LC-TOF). Under optimum conditions, only 5mg of MIL-53(Al) are required for 10mL of water, with the aid of 5min of vortex and 5min of centrifugation. Elution is accomplished with 200µL of acetonitrile (3 times), and evaporation down to 100µL before LC injection. Detection limits down to 0.040μgL -1 for triclosan and 0.013μgL -1 for atrazine are obtained for the entire method using HPLC-DAD and LC-TOF, respectively. The method, operating at low spiked levels (2µgL -1 for HPLC-DAD and 0.7µgL -1 for LC-TOF), is also characterized for average relative recoveries of 109% and 105%; relative standard deviation values lower than 8.7% and 7.5%; and average extraction efficiencies of 41.2% and 49.1%; using HPLC-DAD and LC-TOF, respectively; while demonstrating adequate analytical performance with complex samples such as wastewaters. Copyright © 2017 Elsevier B.V. All rights reserved.
Asea, Philip E; MacNeil, James D; Boison, Joe O
2006-01-01
A method was developed and validated to screen for residues of the thyreostatic drugs, tapazole (TAP), mercaptobenzimidazole (MBI), thiouracil (TU), methylthiouracil (MTU), propylthiouracil (PrTU), and phenylthiouracil (PhTU) in bovine, equine, ovine, and porcine thyroid and muscle tissues at concentrations > or = 5 ng/g using 2-methoxy-mercaptobenzimidazole (MeMBI) and dimethylthiouracil (DMTU) as internal standards. In this method, the drugs were solvent extracted from thyroid and muscle tissue and cleaned up on an amino-propyl solid-phase extraction (SPE) cartridge. The unretained fraction containing TAP and MBI and the internal standard, MeMBI, was collected as Fraction 1. The retained fraction containing TU, MTU, PrTU, PhTU, and the internal standard, DMTU, was eluted with 3% acetic acid-isopropanol as Fraction 2. Fraction 1 was further cleaned up on an alumina B SPE cartridge and analyzed by gradient elution on a C18 high-performance liquid chromatography (HPLC) column with ultraviolet detection at wavelengths of 255 and 300 nm. Fraction 2 was taken to dryness, derivatized with 4-chloro-7-nitrobenzo-2-furazan at pH 8, and analyzed by gradient elution on a C18 LC column with mass spectrometry (MS) detection. Any "presumptive positive" test results were submitted for further analysis by LC/MS/MS. The validated method was applied to the analysis of over 300 thyroid tissue samples.
Cuervo, Darío; Loli, Cynthia; Fernández-Álvarez, María; Muñoz, Gloria; Carreras, Daniel
2017-10-15
A complete analytical protocol for the determination of 25 doping-related peptidic drugs and 3 metabolites in urine was developed by means of accurate-mass quadrupole time-of-flight (Q-TOF) LC-MS analysis following solid-phase extraction (SPE) on microplates and conventional SPE pre-treatment for initial testing and confirmation, respectively. These substances included growth hormone releasing factors, gonadotropin releasing factors and anti-diuretic hormones, with molecular weights ranging from 540 to 1320Da. Optimal experimental conditions were stablished after investigation of different parameters concerning sample preparation and instrumental analysis. Weak cation exchange SPE followed by C18 HPLC chromatography and accurate mass detection provided the required sensitivity and selectivity for all the target peptides under study. 2mg SPE on 96-well microplates can be used in combination with full scan MS detection for the initial testing, thus providing a fast, cost-effective and high-throughput protocol for the processing of a large batch of samples simultaneously. On the other hand, extraction on 30mg SPE cartridges and subsequent target MS/MS determination was the protocol of choice for confirmatory purposes. The methodology was validated in terms of selectivity, recovery, matrix effect, precision, sensitivity (limit of detection, LOD), cross contamination, carryover, robustness and stability. Recoveries ranged from 6 to 70% (microplates) and 17-95% (cartridges), with LODs from 0.1 to 1ng/mL. The suitability of the method was assessed by analyzing different spiked or excreted urines containing some of the target substances. Copyright © 2017 Elsevier B.V. All rights reserved.
Lee, Byeong Ill; Park, Min-Ho; Heo, Soon Chul; Park, Yuri; Shin, Seok-Ho; Byeon, Jin-Ju; Kim, Jae Ho; Shin, Young G
2018-03-01
A liquid chromatographic-electrospray ionization-time-of-flight/mass spectrometric (LC-ESI-TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro-elution solid-phase extraction (SPE) for sample preparation and LC-ESI-TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro-elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration 2 ), with the equation y = ax 2 + bx + c was used to fit calibration curves over the concentration range of 3.02-2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within-run and the between-run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC-ESI-TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Johnsen, Elin; Leknes, Siri; Wilson, Steven Ray; Lundanes, Elsa
2015-03-01
Neurons communicate via chemical signals called neurotransmitters (NTs). The numerous identified NTs can have very different physiochemical properties (solubility, charge, size etc.), so quantification of the various NT classes traditionally requires several analytical platforms/methodologies. We here report that a diverse range of NTs, e.g. peptides oxytocin and vasopressin, monoamines adrenaline and serotonin, and amino acid GABA, can be simultaneously identified/measured in small samples, using an analytical platform based on liquid chromatography and high-resolution mass spectrometry (LC-MS). The automated platform is cost-efficient as manual sample preparation steps and one-time-use equipment are kept to a minimum. Zwitter-ionic HILIC stationary phases were used for both on-line solid phase extraction (SPE) and liquid chromatography (capillary format, cLC). This approach enabled compounds from all NT classes to elute in small volumes producing sharp and symmetric signals, and allowing precise quantifications of small samples, demonstrated with whole blood (100 microliters per sample). An additional robustness-enhancing feature is automatic filtration/filter back-flushing (AFFL), allowing hundreds of samples to be analyzed without any parts needing replacement. The platform can be installed by simple modification of a conventional LC-MS system.
Mazzoni, Michela; Rusconi, Marianna; Valsecchi, Sara; Martins, Claudia P. B.; Polesello, Stefano
2015-01-01
An UHPLC-MS/MS multiresidue method based on an on-line solid phase extraction (SPE) procedure was developed for the simultaneous determination of 9 perfluorinated carboxylates (from 4 to 12 carbon atoms) and 3 perfluorinated sulphonates (from 4 to 8 carbon atoms). This work proposes using an on-line solid phase extraction before chromatographic separation and analysis to replace traditional methods of off-line SPE before direct injection to LC-MS/MS. Manual sample preparation was reduced to sample centrifugation and acidification, thus eliminating several procedural errors and significantly reducing time-consuming and costs. Ionization suppression between target perfluorinated analytes and their coeluting SIL-IS were detected for homologues with a number of carbon atoms less than 9, but the quantitation was not affected. Total matrix effect corrected by SIL-IS, inclusive of extraction efficacy, and of ionization efficiency, ranged between −34 and +39%. The percentage of recoveries, between 76 and 134%, calculated in different matrices (tap water and rivers impacted by different pollutions) was generally satisfactory. LODs and LOQs of this on-line SPE method, which also incorporate recovery losses, ranged from 0.2 to 5.0 ng/L and from 1 to 20 ng/L, respectively. Validated on-line SPE-LC/MS/MS method has been applied in a wide survey for the determination of perfluoroalkyl acids in Italian surface and ground waters. PMID:25834752
Optimization for Peptide Sample Preparation for Urine Peptidomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sigdel, Tara K.; Nicora, Carrie D.; Hsieh, Szu-Chuan
2014-02-25
Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides andmore » the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.« less
Lashgari, Maryam; Lee, Hian Kee
2014-11-21
In the current study, a simple, fast and efficient combination of protein precipitation and micro-solid phase extraction (μ-SPE) followed by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) was developed for the determination of perfluorinated carboxylic acids (PFCAs) in fish fillet. Ten PFCAs with different hydrocarbon chain lengths (C5-C14) were analysed simultaneously using this method. Protein precipitation by acetonitrile and μ-SPE by surfactant-incorporated ordered mesoporous silica were applied to the extraction and concentration of the PFCAs as well as for removal of interferences. Determination of the PFCAs was carried out by LC-MS/MS in negative electrospray ionization mode. MS/MS parameters were optimized for multiple reaction monitoring of the analytes. (13)C mass labelled PFOA as a stable-isotopic internal standard, was used for calibration. The detection limits of the method ranged from 0.97 ng/g to 2.7 ng/g, with a relative standard deviation of between 5.4 and 13.5. The recoveries were evaluated for each analyte and were ranged from 77% to 120%. The t-test at 95% confidence level showed that for all the analytes, the relative recoveries did not depend on their concentrations in the explored concentration range. The effect of the matrix on MS signals (suppression or enhancement) was also evaluated. Contamination at low levels was detected for some analytes in the fish samples. The protective role of the polypropylene membrane used in μ-SPE in the elimination of matrix effects was evaluated by parallel experiments in classical dispersive solid phase extraction. The results evidently showed that the polypropylene membrane was significantly effective in reducing matrix effects. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhang, Jie; Bai, Ruoshi; Yi, Xiaoli; Yang, Zhendong; Liu, Xingyu; Zhou, Jun; Liang, Wei
2016-01-01
A fully automated method for the detection of four tobacco-specific nitrosamines (TSNAs) in mainstream cigarette smoke (MSS) has been developed. The new developed method is based on two-dimensional online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE/LC-MS/MS). The two dimensional SPE was performed in the method utilizing two cartridges with different extraction mechanisms to cleanup disturbances of different polarity to minimize sample matrix effects on each analyte. Chromatographic separation was achieved using a UPLC C18 reversed phase analytical column. Under the optimum online SPE/LC-MS/MS conditions, N'-nitrosonornicotine (NNN), N'-nitrosoanatabine (NAT), N'-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) were baseline separated with good peak shapes. This method appears to be the most sensitive method yet reported for determination of TSNAs in mainstream cigarette smoke. The limits of quantification for NNN, NNK, NAT and NAB reached the levels of 6.0, 1.0, 3.0 and 0.6 pg/cig, respectively, which were well below the lowest levels of TSNAs in MSS of current commercial cigarettes. The accuracy of the measurement of four TSNAs was from 92.8 to 107.3%. The relative standard deviations of intra-and inter-day analysis were less than 5.4% and 7.5%, respectively. The main advantages of the method developed are fairly high sensitivity, selectivity and accuracy of results, minimum sample pre-treatment, full automation, and high throughput. As a part of the validation procedure, the developed method was applied to evaluate TSNAs yields for 27 top-selling commercial cigarettes in China. Copyright © 2015 Elsevier B.V. All rights reserved.
Coupling of Ultrafast LC with Mass Spectrometry by DESI
NASA Astrophysics Data System (ADS)
Cai, Yi; Liu, Yong; Helmy, Roy; Chen, Hao
2014-10-01
Recently we reported a desorption electrospray ionization (DESI) interface to combine liquid chromatography (LC) with mass spectrometry (MS) using a new LC eluent splitting strategy through a tiny orifice on LC capillary tube [ J. Am. Soc. Mass Spectrom. 25, 286 (2014)]. The interface introduces negligible dead volume and back pressure, thereby allowing "near real-time" MS detection, fast LC elution, and online MS-directed purification. This study further evaluates the LC/DESI-MS performance with focus of using ultra-fast LC. Using a monolithic C18 column, metabolites in urine can be separated within 1.6 min and can be online collected for subsequent structure elucidation (e.g., by NMR, UV, IR) in a recovery yield up to 99%. Using a spray solvent with alkaline pH, negative ions could be directly generated for acidic analytes (e.g., ibuprofen) in acidic LC eluent by DESI, offering a novel protocol to realize "wrong-way around" ionization for LC/MS analysis. In addition, DESI-MS is found to be compatible with ultra-performance liquid chromatography (UPLC) for the first time.
Zhao, Yong-Gang; Zhang, Yun; Wang, Feng-Lian; Zhou, Jian; Zhao, Qi-Ming; Zeng, Xiu-Qiong; Hu, Mei-Qin; Jin, Mi-Cong; Zhu, Yan
2018-08-01
The novel quaternary ammonium modified magnetic carboxyl-carbon nanotubes (QA-Mag-CCNTs) have been synthesised and characterized. QA-Mag-CCNTs were applied in magnetic dispersive solid phase extraction (Mag-dSPE) for preconcentration of perchlorate from tea leaves prior to liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS) analysis. The Mag-dSPE procedure for preconcentration of perchlorate succeed in overcoming the flaw (containing target analyte randomly) of commercially available SPE cartridge. Under optimal conditions, the results showed higher extraction efficiency of QA-Mag-CCNTs, with recoveries between 85.2% and 107%. And the satisfactory precision with inter-day and intra-day RSD values were lower than 8.0%. Furthermore, QA-Mag-CCNTs were evaluated for reuse up to 20 times. The limit of quantification (LOQ) for perchlorate was 8.21 ng kg -1 . The developed method was successfully applied in tea leaves for food-safety risk monitoring in Zhejiang province, China. The results showed the concentrations of perchlorate in 229 out of 240 collected samples were in the range of 0.082-988 μg kg -1 . It was confirmed that QA-Mag-CCNTs were highly effective materials used for preconcentration of perchlorate. Copyright © 2018 Elsevier B.V. All rights reserved.
Ha, Jing; Song, Ge; Ai, Lian-Feng; Li, Jian-Chen
2016-04-01
A new method using solid phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of six polyether antibiotics, including lasalocid, salinomycin, monensin, narasin, madubamycin and nigericin residues, in foods of animal origin. The samples were extracted with acetonitrile and purified by ENVI-Carb SPE columns after comparing the impurity effect and maneuverability of several SPE cartridges. Subsequently, the analytes were separated on a Hypersil Gold column (2.1×150mm, 5μm) and analyzed by MS/MS detection. The limit of quantization (LOQ) for milk and chicken was 0.4μg/kg, and for chicken livers and eggs, it was 1μg/kg. The linearity was satisfactory with a correlation coefficient of >0.9995 at concentrations ranging from 2 to 100μg/L. The average recoveries of the analytes fortified at three levels ranged from 68.2 to 114.3%, and the relative standard deviations ranged from 4.5 to 12.1%. The method was suitable for quantitative analysis and confirmation of polyether antibiotic residues in foods of animal origin. Copyright © 2016 Elsevier B.V. All rights reserved.
Ferrer, I.; Furlong, E.T.
2001-01-01
A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.
Kenny, O; Brunton, N P; Walsh, D; Hewage, C M; McLoughlin, P; Smyth, T J
2015-04-01
Plant extracts have traditionally been used as sources of natural antimicrobial compounds, although in many cases, the compounds responsible for their antimicrobial efficacy have not been identified. In this study, crude and dialysed extracts from dandelion root (Taraxacum officinale) were evaluated for their antimicrobial properties against Gram positive and Gram negative bacterial strains. The methanol hydrophobic crude extract (DRE3) demonstrated the strongest inhibition of microbial growth against Staphylococcus aureus, methicillin-resistant S. aureus and Bacillus cereus strains. Normal phase (NP) fractionation of DRE3 resulted in two fractions (NPF4 and NPF5) with enhanced antimicrobial activity. Further NP fractionation of NPF4 resulted in two fractions (NPF403 and NPF406) with increased antimicrobial activity. Further isolation and characterisation of compounds in NPF406 using liquid chromatography solid phase extraction nuclear magnetic resonance LC-SPE-NMR resulted in the identification of 9-hydroxyoctadecatrienoic acid and 9-hydroxyoctadecadienoic acid, while the phenolic compounds vanillin, coniferaldehyde and p-methoxyphenylglyoxylic acid were also identified respectively. The molecular mass of these compounds was confirmed by LC mass spectroscopy (MS)/MS. In summary, the antimicrobial efficacy of dandelion root extracts demonstrated in this study support the use of dandelion root as a source of natural antimicrobial compounds. Copyright © 2015 John Wiley & Sons, Ltd.
Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N
2013-01-01
A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.
Marta-Sanchez, Ana Victoria; Caldas, Sergiane Souza; Schneider, Antunielle; Cardoso, Sónia Maria Vaz Sanches; Primel, Ednei Gilberto
2018-05-01
Parabens have been widely used as antimicrobial agents, mainly in food products, pharmaceuticals, and cosmetics. Although they are known as safe preservatives, they also cause some harm to human health, which has been discussed lately. Therefore, the aim of this study was to evaluate the occurrence of nine parabens (including isomers) in mineral and drinking waters, besides in drinking water treatment sludge (DWTS) samples with determination by liquid chromatography tandem mass spectrometry (LC-MS/MS). Both methods solid phase extraction (SPE) and QuEChERS were validated. Calibration curves showed a correlation coefficient of 0.99 for all compounds. LOQ values ranged from 0.04 to 4 μg L -1 in aqueous matrices and from 5 to 500 ng g -1 in DWTS. Recoveries between 70 and 115% were reached with RSD below 20% for all compounds in SPE whereas recoveries between 62 and 119% were found with RSD below 20% for almost all compounds in QuEChERS. Matrix effect had low values (< 20%); it was only above 20% for methylparaben in the SPE and for pentylparaben in the QuEChERS. Using a quick and simple extraction procedures with SPE, QuEChERS, and LC-MS/MS analyses, these methods proved to be selective and sensitive. They were successfully applied to real samples (treated water, mineral water, and sludge), and methylparaben was detected at concentration levels below 0.242 μg L -1 in mineral and treated water samples and 10 ng g -1 in DWTS samples.
Ho, Emmie N M; Kwok, W H; Wong, April S Y; Wan, Terence S M
2012-01-13
Quaternary ammonium drugs (QADs) are anticholinergic agents some of which are known to have been abused or misused in equine sports. A recent review of literature shows that the screening methods reported thus far for QADs mainly cover singly-charged QADs. Doubly-charged QADs are extremely polar substances which are difficult to be extracted and poorly retained on reversed-phase columns. It would be ideal if a comprehensive method can be developed which can detect both singly- and doubly-charged QADs. This paper describes an efficient liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous detection and confirmation of 38 singly- and doubly-charged QADs at sub-parts-per-billion (ppb) to low-ppb levels in equine urine after solid-phase extraction. Quaternary ammonium drugs were extracted from equine urine by solid-phase extraction (SPE) using an ISOLUTE(®) CBA SPE column and analysed by LC/MS/MS in the positive electrospray ionisation mode. Separation of the 38 QADs was achieved on a polar group embedded C18 LC column with a mixture of aqueous ammonium formate (pH 3.0, 10 mM) and acetonitrile as the mobile phase. Detection and confirmation of the 38 QADs at sub-ppb to low-ppb levels in equine urine could be achieved within 16 min using selected reaction monitoring (SRM). Matrix interference of the target transitions at the expected retention times was not observed. Other method validation data, including precision and recovery, were acceptable. The method was successfully applied to the analyses of drug-administration samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Semenistaya, Ekaterina; Zvereva, Irina; Krotov, Grigory; Rodchenkov, Grigory
2016-09-01
Currently liquid chromatography - mass spectrometry (LC-MS) analysis after solid-phase extraction (SPE) on weak cation-exchange cartridges is a method of choice for anti-doping analysis of small bioactive peptides such as growth hormone releasing peptides (GHRPs), desmoporessin, LHRH, and TB-500 short fragment. Dilution of urine samples with phosphate buffer for pH adjustment and SPE on weak cation exchange microelution plates was tested as a means to increase throughput of this analysis. Dilution using 200 mM phosphate buffer provides good buffering capacity without affecting the peptides recoveries. SPE on microelution plates was performed on Waters Positive Pressure-96 Processor with subsequent evaporation of eluates in nitrogen flow. Though the use of smaller sample volume decreases the pre-concentration factor and increases the limits of detection of 5 out of 17 detected peptides, the recovery, linearity, and reproducibility of the microelution extraction were comparable with cartridge SPE. The effectiveness of protocols was confirmed by analysis of urine samples containing ipamorelin, and GHRP-6 and its metabolites. SPE after urine sample dilution with buffer can be used for faster sample preparation. The use of microelution plates decreases consumption of solvents and allows processing of up to 96 samples simultaneously. Cartridge SPE with manual рН adjustment remains the best option for confirmation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Luo, Quanzhou; Yue, Guihua; Valaskovic, Gary A; Gu, Ye; Wu, Shiaw-Lin; Karger, Barry L.
2008-01-01
Following on our recent work, on-line one dimensional (1D) and two dimensional (2D) PLOT/LC-ESI-MS platforms using 3.2 m × 10 μm i.d. poly(styrenedivinylbenzene) (PS-DVB) porous layer open tubular (PLOT) columns have been developed to provide robust, high performance and ultrasensitive proteomic analysis. Using a PicoClear tee, the dead volume connection between a 50 μm i.d. PS-DVB monolithic microSPE column and the PLOT column was minimized. The microSPE/PLOT column assembly provided a separation performance similar to that obtained with direct injection onto the PLOT column at a mobile phase flow rate of 20 nL/min. The trace analysis potential of the platform was evaluated using an in-gel tryptic digest sample of a gel fraction (15 to 40 kDa) of a cervical cancer (SiHa) cell line. As an example of the sensitivity of the system, ∼2.5 ng of protein in 2 μL solution, an amount corresponding to 20 SiHa cells, was subjected to on-line microSPE-PLOT/LC-ESIMS/MS analysis using a linear ion trap MS. 237 peptides associated with 163 unique proteins were identified from a single analysis when using stringent criteria associated with a false positive rate less than 1% . The number of identified peptides and proteins increased to 638 and 343, respectively, as the injection amount was raised to ∼45 ng of protein, an amount corresponding to 350 SiHa cells. In comparison, only 338 peptides and 231 unique proteins were identified (false positive rate again less than 1%) from 750 ng of protein from the identical gel fraction, an amount corresponding to 6000 SiHa cells, using a typical 15 cm × 75 μm i.d. packed capillary column. The greater sensitivity, higher recovery, and higher resolving power of the PLOT column resulted in the increased number of identifications from only ∼5% of the injected sample amount. The resolving power of the microSPE/PLOT assembly was further extended by 2D chromatography via combination of the high-efficiency reversed phase PLOT column with strong cation exchange chromatography (SCX). As an example, 1071 peptides associated with 536 unique proteins were identified from 75 ng of protein from the same gel fraction, an amount corresponding to 600 cells, using 5 ion exchange fractions in online 2D SCX-PLOT/LC-MS. The 2D system, implemented in an automated format, led to simple and robust operation for proteomic analysis. These promising results demonstrate the potential of the PLOT column for ultratrace analysis. PMID:17625912
Boisvert, Michel; Fayad, Paul B; Sauvé, Sébastien
2012-11-19
A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122ng L(-1) while the limit of quantification ranged from 90 to 370ng L(-1). Calibration curves in the wastewater matrix showed good linearity (R(2)≥0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision. Copyright © 2012 Elsevier B.V. All rights reserved.
Bie, Zhenying; Lu, Wei; Zhu, You; Chen, Yusong; Ren, Hubo; Ji, Lishun
2017-01-27
A fully automated, rapid, and reliable method for simultaneous determination of six carcinogenic primary aromatic amines (AAs), including o-toluidine (o-TOL), 2, 6-dimethylaniline (2, 6-DMA), o-anisidine (o-ASD), 1-naphthylamine (1-ANP), 2-naphthylamine (2-ANP), and 4-aminobiphenyl (4-ABP), in mainstream cigarette smoke was established. The proposed method was based on two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry (SPE/LC-MS/MS). The particulate phase of the mainstream cigarette smoke was collected on a Cambridge filter pad and pretreated via ultrasonic extraction with 2% formic acid (FA), while the gas phase was trapped by 2% FA without pretreatment for determination. The two-dimensional online SPE comprised of two cartridges with different absorption characteristics was applied for sample pretreatment. Analysis was performed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) under multiple reaction monitoring mode. Each sample required about 0.5h for solid phase extraction and analysis. The limit of detections (LODs) for six AAs ranged from 0.04 to 0.58ng/cig and recoveries were within 84.5%-122.9%. The relative standard deviations of intra- and inter-day tests for 3R4F reference cigarette were less than 6% and 7%, respectively, while no more than 7% and 8% separately for a type of Virginia cigarette. The proposed method enabled minimum sample pretreatment, full automation, and high throughput with high selectivity, sensitivity, and accuracy. As a part of the validation procedure, fifteen brands of cigarettes were tested by the designed method. Copyright © 2016 Elsevier B.V. All rights reserved.
Godin, Jean-Philippe; McCullagh, James S O
2011-10-30
High-precision isotope analysis is recognized as an essential research tool in many fields of study. Until recently, continuous flow isotope ratio mass spectrometry (CF-IRMS) was available via an elemental analyzer or a gas chromatography inlet system for compound-specific analysis of light stable isotopes. In 2004, however, an interface that coupled liquid chromatography with IRMS (LC/IRMS) became commercially available for the first time. This brought the capability for new areas of application, in particular enabling compound-specific δ(13)C analysis of non-volatile, aqueous soluble, compounds from complex mixtures. The interface design brought with it several analytical constraints, however, in particular a lack of compatibility with certain types of chromatography as well as limited flow rates and mobile phase compositions. Routine LC/IRMS methods have, however, been established for measuring the δ(13)C isotopic ratios of underivatized individual compounds for application in archeology, nutrition and physiology, geochemistry, hydrology, soil science and food authenticity. Seven years after its introduction, we review the technical advances and constraints, methodological developments and new applications of liquid chromatography coupled to isotope ratio mass spectrometry. Copyright © 2011 John Wiley & Sons, Ltd.
Ordóñez, Edgar Y; Quintana, José Benito; Rodil, Rosario; Cela, Rafael
2012-09-21
The development and performance evaluation of an analytical method for the determination of six artificial sweeteners in environmental waters using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry are presented. To this end, different SPE alternatives have been evaluated: polymeric reversed-phase (Oasis HLB, Env+, Plexa and Strata X), and mixed-mode with either weak (Oasis WAX) or strong anionic-exchange (Oasis MAX and Plexa PAX) sorbents. Among them, reversed-phase sorbents, particularly Oasis HLB and Strata X, showed the best performance. Oasis HLB provided good trueness (recoveries: 73-112%), precision (RSD<10%) and limits of quantification (LOQ: 0.01-0.5 μg/L). Moreover, two LC separation mechanisms were evaluated: reversed-phase (RPLC) and hydrophilic interaction (HILIC), with RPLC providing better performance than HILIC. The final application of the method showed the presence of acesulfame, cyclamate, saccharin and sucralose in the wastewater and surface water samples analyzed at concentrations up to 54 μg/L. Copyright © 2012 Elsevier B.V. All rights reserved.
van der Heeft, E; Dijkman, E; Baumann, R A; Hogendoorn, E A
2000-05-19
The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods the data agreed very well with the true values of the samples.
Áragón, Alvaro; Toledano, Rosa M; Cortés, José M; Vázquez, Ana M; Villén, Jesús
2014-04-25
The through oven transfer adsorption desorption (TOTAD) interface allows large volume injection (LVI) in gas chromatography and the on-line coupling of liquid chromatography and gas chromatography (LC-GC), enabling the LC step to be carried out in normal as well as in reversed phase. However, large amounts of helium, which is both expensive and scarce, are necessary for solvent elimination. We describe how slight modification of the interface and the operating mode allows nitrogen to be used during the solvent elimination steps. In order to evaluate the performance of the new system, volumes ranging from 20 to 100μL of methanolic solutions of four polycyclic aromatic hydrocarbons (PAHs) were sampled. No significant differences were found in the repeatability and sensitivity of the analyses of standard PAH solutions when using nitrogen or helium. The performance using the proposed modification was similar and equally satisfactory when using nitrogen or helium for solvent elimination in the TOTAD interface. In conclusion, the use of nitrogen will make analyses less expensive. Copyright © 2014 Elsevier B.V. All rights reserved.
Analysis of coffee for the presence of acrylamide by LC-MS/MS.
Andrzejewski, Denis; Roach, John A G; Gay, Martha L; Musser, Steven M
2004-04-07
A variety of popular instant, ground, and brewed coffees were analyzed using a modified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method specifically developed for the determination of acrylamide in foods. Coffee test portions were spiked with 13C3-labeled acrylamide as an internal standard prior to their extraction and cleanup. Ground coffees (1 g) and instant coffees (0.5 g) were extracted by shaking with 9 mL of water for 20 min. Brewed coffee test portions (9 mL) were taken through the cleanup procedure without further dilution with extraction solvent. Coffee test portions were cleaned up by passing 1.5 mL first through an Oasis HLB (hydrophilic/lipophilic copolymer sorbent) solid phase extraction (SPE) cartridge and then a Bond Elut-Accucat (cation and anion exchange sorbent) SPE cartridge. The cleaned up extracts were analyzed by positive ion electrospray LC-MS/MS. The MS/MS data was used to detect, confirm, and quantitate acrylamide. The limit of quantitation of the method was 10 ng/g for ground and instant coffees and 1.0 ng/mL for brewed coffee. The levels of acrylamide ranged from 45 to 374 ng/g in unbrewed coffee grounds, from 172 to 539 ng/g in instant coffee crystals, and from 6 to 16 ng/mL in brewed coffee.
Lipidomic analysis of glycerolipid and cholesteryl ester autooxidation products.
Kuksis, Arnis; Suomela, Jukka-Pekka; Tarvainen, Marko; Kallio, Heikki
2009-06-01
Thin-layer chromatography (TLC), gas chromatography (GC), and liquid chromatography (LC) in combination with mass spectrometry (MS) have been adopted for the isolation and identification of oxolipids and for determining their functionality. TLC provides a rapid separation and access to most oxolipids as intact molecules and has recently been effectively interfaced with time-of-flight (TOF) MS (TOF-MS). GC with flame ionization (FI) (GC/FI) and electron impact (EI) MS (GC/EI-MS) has been extensively utilized in the analysis of isoprostanes and other low-molecular-weight oxolipids, although these methods require derivatization of the analytes. In contrast, LC with ultraviolet (UV) absorption (LC/UV) or evaporate light scattering detection (ELSD) (LC/ELSD) as well as electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) MS (LC/ESI-MS) or LC/APCI-MS has proven to be well suited for the analysis of intact oxolipids and their conjugates without or with minimal derivatization. Nevertheless, kit-based colorimetric and fluorescent procedures continue to serve as sensitive indicators of the presence of hydroperoxides and aldehydes.
He, Ke; Timm, Anne; Blaney, Lee
2017-08-04
Ultraviolet-filters (UV-filters) and estrogens have attracted increased attention as contaminants of emerging concern (CECs) due to their widespread occurrence in the environment. Most of these CECs are hydrophobic and have the potential to accumulate in aquatic organisms. To date, co-analysis of UV-filters and estrogens has not been reported due, in part, to the complex environmental matrices. Here, a multi-residue method has been developed for simultaneous determination of five UV-filters and three estrogens in tissue from aquatic and marine organisms. The procedure involved a modified Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction with a novel reverse-solid-phase extraction (reverse-SPE) cleanup in place of dispersive-SPE, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. The tissue mass, acetonitrile content, and salt conditions for QuEChERS extraction, along with the reverse-SPE cartridge material and elution conditions, were thoroughly investigated and optimized. Five UV-filters (i.e., 3-(4-methylbenzylidene) camphor, benzophenone-3, ethylhexylmethoxycinnamate, homosalate, and octocrylene) and three estrogens (i.e., estrone, 17β-estradiol, and 17α-ethinylestradiol) were simultaneously analyzed by taking advantage of wrong-way-round ionization in LC-MS/MS. The optimized analytical protocol exhibited good recoveries (>80%) for target compounds and enabled their detection at concentrations as low as 0.2ng/g in 50mg tissue samples. The method was applied to determine concentrations of target analytes in four invertebrates (i.e., Orconectes virilis, Procambarus clarkii, Crassostrea virginica, and Ischadium recurvum). All eight target analytes were detected at least once in the tissue samples, with the highest concentration being 399ng/g of homosalate in O. virilis. These results highlight the ubiquitous bioaccumulation of CECs in aquatic and marine invertebrates. Copyright © 2017 Elsevier B.V. All rights reserved.
Bourgogne, Emmanuel; Culot, Benoit; Dell'Aiera, Sylvie; Chanteux, Hugues; Stockis, Armel; Nicolas, Jean-Marie
2018-06-01
Brivaracetam (BRV) is a new high affinity synaptic vesicle protein 2A ligand recently approved for adults with partial-onset seizures. As a support to in vitro metabolism assays, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method coupled to off-line solid phase extraction (SPE) was developed to quantify BRV acid metabolites, that is, BRV-AC (carboxylic derivative derived from BRV hydrolysis) and BRV-OHAC (corresponding to hydroxylated BRV-AC). The method was validated for various incubates (liver and kidney tissue homogenates and blood, all from humans) and applied to in vitro metabolism assays. The analytes were isolated from buffered samples using ISOLUTE C8 96-well SPE plates. Chromatographic separation was achieved on a Waters Atlantis T3 C18 analytical column (2.1 mm × 50 mm, 5 μm) with detection accomplished using a Waters Premier tandem mass spectrometer in positive ion electrospray and multiple reaction monitoring (MRM) mode. The standard curves, which ranged from 1.00 to 200 ng/mL for BRV-AC, BRV-OHAC, were fitted to a 1/x 2 weighted linear regression model. The intra-assay precision and inter-assay precision (expressed as coefficient of variation -%CV) were <8.5%, and the assay accuracy (deviation - %Dev) was within ±7.1% for the different matrices. This accurate, precise, and selective SPE/LC-MS/MS method has been successfully applied to in vitro assays aimed at characterizing the kinetics of BRV hydrolysis. BRV was found to be a better substrate for hydrolysis than its hydroxylated metabolite BRV-OH. BRV hydrolysis was detected in blood, liver and kidneys, demonstrating the broad distribution of the enzyme catalyzing the reaction. Copyright © 2018 Elsevier B.V. All rights reserved.
Yu, Jingjing; Wang, Sheng; Zhao, Ge; Wang, Bing; Ding, Li; Zhang, Xiaobing; Xie, Jianping; Xie, Fuwei
2014-05-01
Urinary aromatic amines (AAs) could be used as biomarkers for human exposure to AAs in cigarette smoke. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of urinary AAs (i.e. 1-naphthylamine (1-NA), 2-naphthylamine (2-NA), 3-aminobiphenyl (3-ABP) and 4-aminobiphenyl (4-ABP)) in smokers and nonsmokers. A molecularly imprinted polymers (MIPs) solid phase extraction (SPE) cartridge was applied to purify urine samples and no derivatization reaction was involved. Each analytes used respective stable isotope internal standards, which could well compensate matrix effect. Lower limit of detections (LODs) for four AAs were obtained and in the range of 1.5-5ngL(-1). Recovery ranged from 87.7±4.5% to 111.3±6.4% and precision were less than 9.9%. The method was applied to analyze urine samples of 40 smokers and 10 nonsmokers. The 24h urinary excretion amounts of total AAs were higher for smokers compared with nonsmokers. What's more, 1-NA, 3-ABP and 4-ABP excretion amounts showed significant differences (p<0.05) between smokers and nonsmokers. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Salikin, Jamilah; Abdullah, Aminah
2013-11-01
A methodusingliquid chromatography-electrospray mass spectrometry (LC-(ESI)MS) for the simultaneous determination of three macrolides (tylosin, spiramycin and tilmicosin) in poultry muscle has been developed. The drugs were extracted with EDTA McIlvaine buffer, filter through celite 545 and the extracts were cleaned up by SPE Oasis HLB cartridge. Separation was carried out in end-capped silica-based C18 column and mobile phases containing trifluoroacetic acid-acetonitrile with a binary gradient system at a flow rate 0.5 ml/min. Detection was performed by single mass spectrometry with electrospray ionization in the positive mode. Several parameters affecting the mass spectra were studied. Chicken samples from the market were analyzed to check the residue of macrolide antibiotics.
Ok, Hyun Ee; Tian, Fei; Hong, Eun Young; Paek, Ockjin; Kim, Sheen-Hee; Kim, Dongsul; Chun, Hyang Sook
2016-01-01
An interlaboratory study was performed in eight laboratories to validate a liquid chromatography–tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of aflatoxins and sterigmatocystin (STC) in white rice and sorghum (Sorghum bicolor). Fortified samples (at three different levels) of white rice and sorghum were extracted, purified through a solid-phase extraction (SPE) column, and then analyzed by LC/MS/MS. The apparent recoveries (ARs) ranged from 78.8% to 95.0% for aflatoxins and from 85.3% to 96.7% for STC. The relative standard deviations for repeatability (RSDr) and reproducibility (RSDR) of aflatoxins were in the ranges 7.9%–33.8% and 24.4%–81.0%, respectively. For STC, the RSDr ranged from 7.1% to 40.2% and the RSDR ranged from 28.1% to 99.2%. The Horwitz ratio values for the aflatoxins and STC ranged from 0.4 to 1.2 in white rice and from 0.3 to 1.0 in sorghum, respectively. These results validated this method for the simultaneous determination of aflatoxins and STC by LC/MS/MS after SPE column cleanup. The percentages of satisfactory Z-score values (|Z| ≤ 2) were the following: for white rice, 100% for aflatoxins and STC; for sorghum, 100%, except in data from two laboratories for STC (0.3 μg/kg). This validated that the LC/MS/MS method was successfully applied for the determination of aflatoxins and STC in 20 white rice and 20 sorghum samples sourced from Korean markets. PMID:27983588
Mixed-mode chromatography/isotope ratio mass spectrometry.
McCullagh, James S O
2010-03-15
Liquid chromatography coupled to molecular mass spectrometry (LC/MS) has been a standard technique since the early 1970s but liquid chromatography coupled to high-precision isotope ratio mass spectrometry (LC/IRMS) has only been available commercially since 2004. This development has, for the first time, enabled natural abundance and low enrichment delta(13)C measurements to be applied to individual analytes in aqueous mixtures creating new opportunities for IRMS applications, particularly for the isotopic study of biological molecules. A growing number of applications have been published in a range of areas including amino acid metabolism, carbohydrates studies, quantification of cellular and plasma metabolites, dietary tracer and nucleic acid studies. There is strong potential to extend these to new compounds and complex matrices but several challenges face the development of LC/IRMS methods. To achieve accurate isotopic measurements, HPLC separations must provide baseline-resolution between analyte peaks; however, the design of current liquid interfaces places severe restrictions on compatible flow rates and in particular mobile phase compositions. These create a significant challenge on which reports associated with LC/IRMS have not previously focused. Accordingly, this paper will address aspects of chromatography in the context of LC/IRMS, in particular focusing on mixed-mode separations and their benefits in light of these restrictions. It aims to provide an overview of mixed-mode stationary phases and of ways to improve high aqueous separations through manipulation of parameters such as column length, temperature and mobile phase pH. The results of several practical experiments are given using proteogenic amino acids and nucleosides both of which are of noted importance in the LC/IRMS literature. This communication aims to demonstrate that mixed-mode stationary phases provide a flexible approach given the constraints of LC/IRMS interface design and acts as a practical guide for the development of new chromatographic methods compatible with LC/IRMS applications. Copyright 2010 John Wiley & Sons, Ltd.
Ponce-Robles, Laura; Rivas, Gracia; Esteban, Belen; Oller, Isabel; Malato, Sixto; Agüera, Ana
2017-10-01
An analytical method was developed and validated for the determination of ten pesticides in sewage sludge coming from an agro-food industry. The method was based on the application of Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) extraction for solid sewage sludge and SPE extraction for sludge aqueous phase, followed by liquid chromatography (LC) coupled to hybrid quadrupole/linear ion trap mass spectrometry (QqLIT-MS). The QuEChERS method was reported 14 years ago and nowadays is mainly applied to the analysis of pesticides in food. More recent applications have been reported in other matrices as sewage sludge, but the complexity of the matrix makes necessary the optimization of the cleanup step to improve the efficiency of the analysis. With this aim, several dispersive solid-phase extraction cleanup sorbents were tested, choosing C18 + PSA as a d-SPE sorbent. The proposed method was satisfactorily validated for most compounds investigated, showing recoveries higher than 80% in most cases, with the only exception of prochloraz (71%) at low concentration level. Limits of quantification were lower than 40 ng l -1 in the aqueous phase and below 40 ng g -1 in the solid phase for the majority of the analytes. The method was applied to solid sludge and the sludge aqueous phase coming from an agro-food industry which processes fruits and vegetables. Graphical abstract Application of LC/MS/MS advanced analytical techniques for determination of pesticides contained in sewage sludge.
Rousis, Nikolaos I; Zuccato, Ettore; Castiglioni, Sara
2016-11-15
Biomonitoring studies have documented the high exposure of the population to pesticides which are widely used for crop protection, industrial and household purposes. This is the first study which has measured human urinary metabolites of pesticides in urban wastewater as biomarkers of population exposure. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to measure fifteen urinary metabolites selected from the major classes of pesticides. Raw wastewater samples were processed by solid phase extraction (SPE) or direct injection into the LC-MS/MS system. Recoveries ranged from 75 to 115% and the limits of quantification were 1-15ng/L for the SPE method and 40-800ng/L for direct injection. The method was employed for the analysis of 44 composite 24-h wastewater samples collected in seven Italian cities. Most of the target substances were detected at concentrations ranging from 1.1ng/L to 1.6μg/L. The highest concentrations were for some common metabolites of alkyl phosphates and pyrethroids and the specific metabolite of chlorpyrifos and chlorpyrifos-methyl (3,5,6-trichloro-2-pyridinol). The frequency of detection and abundance of most of the measured metabolites were in line with the profiles reported in urine biomonitoring studies. This method is therefore proposed as a novel "biomonitoring approach" for obtaining objective, direct information on the levels of exposure of a specific population to pesticides, and current research is addressed to validate the method identifying the most reliable biomarkers. Copyright © 2016 Elsevier B.V. All rights reserved.
Exarchou, Vassiliki; Godejohann, Markus; van Beek, Teris A; Gerothanassis, Ioannis P; Vervoort, Jacques
2003-11-15
Structure elucidation of natural products usually relies on a combination of NMR spectroscopy with mass spectrometry whereby NMR trails MS in terms of the minimum sample amount required. In the present study, the usefulness of on-line solid-phase extraction (SPE) in LC-NMR for peak storage after the LC separation prior to NMR analysis is demonstrated. The SPE unit allows the use of normal protonated solvents for the LC separation and fully deuterated solvents for flushing the trapped compounds to the NMR probe. Thus, solvent suppression is no longer necessary. Multiple trapping of the same analyte from repeated LC injections was utilized to solve the problem of low concentration and to obtain 2D heteronuclear NMR spectra. In addition, a combination of the SPE unit with a recently developed cryoflow NMR probe and an MS was evaluated. This on-line LC-UV-SPE-NMR-MS system was used for the automated analysis of a Greek oregano extract. Combining the data provided by the UV, MS, and NMR spectra, the flavonoids taxifolin, aromadendrin, eriodictyol, naringenin, and apigenin, the phenolic acid rosmarinic acid, and the monoterpene carvacrol were identified. This automated technique is very useful for natural product analysis, and the large sensitivity improvement leads to significantly reduced NMR acquisition times.
Vázquez, P Parrilla; Lozano, A; Uclés, S; Ramos, M M Gómez; Fernández-Alba, A R
2015-12-24
Several clean-up methods were evaluated for 253 pesticides in pollen samples concentrating on efficient clean-up and the highest number of pesticides satisfying the recovery and precision criteria. These were: (a) modified QuEChERS using dSPE with PSA+C18; (b) freeze-out prior to QuEChERS using dSPE with PSA+C18; (c) freeze-out prior to QuEChERS using dSPE with PSA+C18+Z-Sep; and (d) freeze-out followed by QuEChERS using dSPE with PSA+C18 and SPE with Z-Sep. Determinations were made using LC-MS/MS and GC-MS/MS. The modified QuEChERS protocol applying a freeze-out followed by dSPE with PSA+C18 and SPE clean-up with Z-Sep was selected because it provided the highest number of pesticides with mean recoveries in the 70-120% range, as well as relative standard deviations (RSDs) typically below 20% (12.2% on average) and ensured much better removal of co-extracted matrix compounds of paramount importance in routine analysis. Limits of quantification at levels as low as 5μgkg(-1) were obtained for the majority of the pesticides. The proposed methodology was applied to the analysis of 41 pollen bee samples from different areas in Spain. Pesticides considered potentially toxic to bees (DL50<2μg/bee) were detected in some samples with concentrations up to 72.7μgkg(-1), which could negatively affect honeybee health. Copyright © 2015 Elsevier B.V. All rights reserved.
Kamel, Alaa
2010-05-26
An analytical method was refined for the extraction and determination of neonicotinoid pesticide residues and their metabolites in honey bees and bee products. Samples were extracted with 2% triethylamine (TEA) in acetonitrile (ACN) followed by salting out, solid phase extraction (SPE) cleanup, and detection using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated in triplicate at three fortification concentrations in each matrix. Good recoveries were observed for most analytes and ranged between 70 and 120% with relative standard deviations between replicates of <20% in most cases. The method limits of detection were 0.2 ng/g for the parent neonicotinoid pesticides and ranged between 0.2 and 15 ng/g for the neonicotinoid metabolites. This refined method provides lower detection limits and improved recovery of neonicotinoids and their metabolites, which will help researchers evaluate subchronic effects of these pesticides, address data gaps related to colony collapse disorder (CCD), and determine the role of pesticides in pollinator decline.
MacMahon, Shaun; Ridge, Clark D; Begley, Timothy H
2014-12-03
A new analytical method has been developed and validated for the detection and quantification of 2-monochloropropanediol (2-MCPD) esters in edible oils. The target compounds are potentially carcinogenic contaminants formed during the processing of edible oils. As the 2-MCPD esters that occur most frequently in refined edible oils were not commercially available, standards were synthesized with identity and purity (95+%) confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and (1)H NMR. Target analytes are separated from edible oil matrices using a two-step solid-phase extraction (SPE) procedure. The extracts are then analyzed using LC-MS/MS with electrospray ionization (ESI). The method has been validated for 11 2-MCPD diesters and 3 2-MCPD monoesters in soybean oil, olive oil, and palm oil using an external calibration curve. The ranges of average recoveries and relative standard deviations (RSD) across the three oil matrices at three spiking concentrations are 79-106% (3-13% RSD) for the 2-MCPD diesters and 72-108% (4-17% RSD) for the 2-MCPD monoesters, with limits of quantitation at or below 30 ng/g for the diesters and 90 ng/g for the monoesters.
Herrero-Hernández, E; Carabias-Martínez, R; Rodríguez-Gonzalo, E
2009-09-21
An extraction-preconcentration procedure based on the use of a molecularly imprinted polymer (MIP) as selective sorbent has been developed for the determination of several phenolic compounds (bisphenol-A, bisphenol-F and 4-nitrophenol) and phenoxyacid herbicides (2,4-D, 2,4,5-T and 2,4,5-TP) in honey samples. Liquid chromatography with diode array detection (LC-DAD) and electrospray ionisation-ion trap mass spectrometry (LC-IT-MS) were used for the separation, identification and quantification of these analytes. The molecularly imprinted polymer was obtained by precipitation polymerisation with bisphenol-A (BPA) as template and 4-vinylpyridine as the functional monomer. The behaviour of this sorbent was compared with those of other materials frequently used in SPE. The selectivity of the BPA-MIP for the target analytes was tested in samples containing other pesticides in common use. The recoveries achieved for all six compounds were in the 81-96% range. By applying the proposed procedure prior to LC-IT-MS, the limits of detection achieved in commercial honey samples were in the 0.1-3.8 ng g(-1) range, with relative standard deviations of 12-24%.
Pang, G-F; Fan, C-L; Liu, Y-M; Cao, Y-Z; Zhang, J-J; Fu, B-L; Li, X-M; Li, Z-Y; Wu, Y-P
2006-08-01
A multi-residue method was developed for the determination of 450 pesticide residues in honey, fruit juice and wine using double-cartridge solid-phase extraction (SPE), gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The method development was based on an appraisal of the characteristics of GC-MS and LC-MS-MS for 654 pesticides as well as the efficiency of extraction and purification from honey, fruit juice and wine. Samples were first diluted with water plus acetone, then extracted with portions of dichloromethane. The extracts were concentrated and cleaned up with graphitized carbon black and aminopropyl cartridges stacked in tandem. Pesticides were eluted with acetonitrile + toluene, and the eluates were concentrated. For 383 pesticides, the eluate was extracted with hexane twice and internal standard solution was added prior to GC-MS determination. For 67 pesticides, extraction was with methanol prior to LC-MS-MS determination. The limit of detection for the method was between 1.0 and 300 ng g(-1) depending on each pesticide analyte. At the three fortification levels of 2.0-3000 ng g(-1), the average recovery rates were between 59 and 123%, among which 413 pesticides (92% of the 450) had recovery rates of 70-120% and 35 pesticides (8% of the 450) had recovery rates of 59-70%. There were 437 pesticides (97% of the 450) with a relative standard deviation below 25%; there were 13 varieties (3% of the 450) between 25.0 and 30.4%.
Yang, Yunjia; Yu, Jianlong; Yin, Jie; Shao, Bing; Zhang, Jing
2014-11-19
This study aimed to develop a selective analytical method for the simultaneous determination of seven bisphenol analogues in beverage and canned food samples by using a new molecularly imprinted polymer (MIP) as a sorbent for solid-phase extraction (SPE). Liquid chromatography coupled to triple-quadruple tandem mass spectrometry (LC-MS/MS) was used to identify and quantify the target analytes. The MIP-SPE method exhibited a higher level of selectivity and purification than the traditional SPE method. The developed procedures were further validated in terms of accuracy, precision, and sensitivity. The obtained recoveries varied from 50% to 103% at three fortification levels and yielded a relative standard deviation (RSD, %) of less than 15% for all of the analytes. The limits of quantification (LOQ) for the seven analytes varied from 0.002 to 0.15 ng/mL for beverage samples and from 0.03 to 1.5 ng/g for canned food samples. This method was used to analyze real samples that were collected from a supermarket in Beijing. Overall, the results revealed that bisphenol A and bisphenol F were the most frequently detected bisphenols in the beverage and canned food samples and that their concentrations were closely associated with the type of packaging material. This study provides an alternative method of traditional SPE extraction for screening bisphenol analogues in food matrices.
Tölgyesi, Adám; Sharma, Virender K; Fekete, Jeno
2011-02-15
A new method was developed to determine five corticosteroids (prednisolone, methylprednisone, flumethasone, dexamethasone, and methylprednisolone) in pig fat samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) utilizing an optimized liquid-liquid extraction (LLE) and subsequent solid-phase extraction (SPE) for sample clean-up. In the sample preparation, a pig fat sample was dissolved in n-hexane and then extracted into the methanol-water (50/50, v/v) mixture that enabled extraction of only medium polar corticosteroids and not the non-polar components of matrices. This extract was cleaned-up and concentrated on polymeric Oasis HLB SPE cartridge. Separation involved isocratic solvent (methanol-acetate buffer, pH 5.4) and Ascentis Express Fused-Core type HLPC column; reduced the analysis time to 7.5 min, which is at least two times lower than time required for separation using conventional techniques. Other advantage of the developed method is the minimized ion suppression of LC-MS/MS analysis, which allowed detection of corticosteroids in sub μg/kg. Method was validated according to European Union (EU) Commission Decision 2002/657/EC. Measured parameters such as selectivity, linearity, recovery, within-laboratory reproducibility, decision limit, and detection capability satisfied the EU Directive. Ranges of mean recoveries and within-laboratory reproducibility were 81-100% and 8.0-20.5%, respectively. Decision limits were calculated in the range from 4.5 to 11.9 μg/kg for MRL compounds and varied from 0.1 to 0.2 μg/kg for banned substances. Limit of detections (LODs), calculated as three time signal-to-noise ratio, were in the range of 0.1-0.3 μg/kg. Copyright © 2010 Elsevier B.V. All rights reserved.
Raina, Renata; Etter, Michele L.
2010-01-01
A new liquid chromatography (LC)-negative ion electrospray ionization (ESI−)–tandem mass spectrometry (MS/MS) method with post-column addition of ammonia in methanol has been developed for the analysis of acid herbicides: 2,4-dichlorophenoxy acetic acid, 4-chloro-o-tolyloxyacetic acid, 2-(2-methyl-4-chlorophenoxy)butyric acid, mecoprop, dichlorprop, 4-(2,4-dichlorophenoxy) butyric acid, 2,4,5-trichlorophenoxy propionic acid, dicamba and bromoxynil, along with their degradation products: 4-chloro-2-methylphenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and 3,5-dibromo-4-hydroxybenzoic acid. The samples were extracted from the surface water matrix using solid-phase extraction (SPE) with a polymeric sorbent and analyzed with LC ESI− with selected reaction monitoring (SRM) using a three-point confirmation approach. Chromatography was performed on a Zorbax Eclipse XDB-C18 (50 × 4.6 mm i.d., 1.8 μm) with a gradient elution using water-methanol with 2 mM ammonium acetate mobile phase at a flow rate of 0.15 mL/min. Ammonia in methanol (0.8 M) was added post-column at a flow rate of 0.05 mL/min to enhance ionization of the degradation products in the MS source. One SRM transition was used for quantitative analysis while the second SRM along with the ratio of SRM1/SRM2 within the relative standard deviation determined by standards for each individual pesticide and retention time match were used for confirmation. The standard deviation of ratio of SRM1/SRM2 obtained from standards run on the day of analysis for different phenoxyacid herbicides ranged from 3.9 to 18.5%. Limits of detection (LOD) were between 1 and 15 ng L−1 and method detection limits (MDL) with strict criteria requiring <25% deviation of peak area from best-fit line for both SRM1 and SRM2 ranged from 5 to 10 ng L−1 for acid ingredients (except dicamba at 30 ng L−1) and from 2 to 30 ng L−1 for degradation products. The SPE-LC-ESI− MS/MS method permitted low nanogram-per-liter determination of pesticides and degradation products for surface water samples. PMID:20212919
Farre, M.; Ferrer, I.; Ginebreda, A.; Figueras, M.; Olivella, L.; Tirapu, L.; Vilanova, M.; Barcelo, D.
2001-01-01
In the present work a combined analytical method involving toxicity and liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) was developed for the determination of pharmaceutical compounds in water samples. The drugs investigated were the analgesics: ibuprofen, ketoprofen, naproxen, and diclofenac, the decomposition product of the acetyl salicylic acid: salicylic acid and one lipid lowering agent, gemfibrozil. The selected compounds are acidic substances, very polar and all of them are analgesic compounds that can be purchased without medical prescription. The developed protocol consisted, first of all, on the use Microtox?? and ToxAlert??100 toxicity tests with Vibrio fischeri for the different pharmaceutical drugs. The 50% effective concentration (EC50) values and the toxicity units (TU) were determined for every compound using both systems. Sample enrichment of water samples was achieved by solid-phase extraction procedure (SPE), using the Merck LiChrolut?? EN cartridges followed by LC-ESI-MS. Average recoveries loading 1 l of samples with pH=2 varied from 69 to 91% and the detection limits in the range of 15-56 ng/l. The developed method was applied to real samples from wastewater and surface-river waters of Catalonia (north-east of Spain). One batch of samples was analyzed in parallel also by High Resolution Gas Chromatography coupled with Mass Spectrometry (HRGC-MS) and the results have been compared with the LC-ESI-MS method developed in this work. ?? 2001 Elsevier Science B.V. All rights reserved.
Bengtson Nash, S M; Schreiber, U; Ralph, P J; Müller, J F
2005-01-15
Mounting concerns regarding the environmental impact of herbicides has meant a growing requirement for accurate, timely information regarding herbicide residue contamination of, in particular, aquatic systems. Conventional methods of detection remain limited in terms of practicality due to high costs of operation and the specialised information that analysis provides. A new phytotoxicity bioassay was trialled for the detection of herbicide residues in filter-purified (Milli-Q) as well as natural waters. The performance of the system, which combines solid-phase extraction (SPE) with the ToxY-PAM dual-channel yield analyser (Heinz Walz GmbH), was tested alongside the traditional method of liquid chromatography-mass spectrometry (LC-MS). The assay methodology was found to be highly sensitive (LOD 0.1 ng L(-1) diuron) with good reproducibility. The study showed that the assay protocol is time effective and can be employed for the aquatic screening of herbicide residues in purified as well as natural waters.
Saber, Amr L
2009-04-15
An instrumental setup including on-line solid phased extraction coupled to capillary liquid chromatography-electrospray ionization-mass spectrometry (SPE-capLC-ESI-MS) has been constructed to improve the sensitivity for quantification of fluoxetine hydrochloride in human plasma. Prior to injection, 0.5 mL of plasma spiked with metronidazole (internal standard) was mixed with ammonium formate buffer for effective chloroform liquid-liquid extraction. The method was validated in the range 5-60 ng mL(-1) fluoxetine, yielding a correlation coefficient of 0.999 (r(2)). The within-assay and between-assay precisions were between (8.5 and 11%) and (6.6 and 7.5%), respectively. The method was used to determine the amount of fluoxetine in a healthy male 14 h after an intake of one capsule of the antidepressant and anorectic Flutin, which contains 20mg fluoxetine per each capsule. Fluoxetine was detected, and the concentration was calculated to 9.0 ng mL(-1) plasma. In the preliminary experiments, conventional LC-UV instrumentation was employed. However, it was found that employing a capillary column with an inner diameter of (0.3mm I.D. x 50 mm, Zorbax C(18)) increased the sensitivity by a factor of approximately 100, when injecting the same mass of analyte. Incorporating an easily automated C(18) reversed phase column switching system with SPE (1.0mm I.D. x 5.0mm, 5 microm) made it possible to inject up to 100 microL of solution, and the total analysis time was 5.5 min.
Rahman, Md Musfiqur; Park, Jong-Hyouk; Abd El-Aty, A M; Choi, Jeong-Heui; Yang, Angel; Park, Ki Hun; Nashir Uddin Al Mahmud, Md; Im, Geon-Jae; Shim, Jae-Han
2013-01-15
A new analytical method was developed for dinotefuran and its metabolites, MNG, UF, and DN, in melon using high-performance liquid chromatography (HPLC) coupled with an ultraviolet detector (UVD). Due to shorter wavelength, lower sensitivity to UV detection, and high water miscibility of some metabolites, QuEChERs acetate-buffered version was modified for extraction and purification. Mobile phases with different ion pairing or ionisation agents were tested in different reverse phase columns, and ammonium bicarbonate buffer was found as the best choice to increase the sensitivity of target analytes to the UV detector. After failure of dispersive SPE clean-up with primary secondary amine, different solid phase extraction cartridges (SPE) were used to check the protecting capability of analytes against matrix interference. Finally, samples were extracted with a simple and rapid method using acetonitrile and salts, and purified through C(18)SPE. The method was validated at two spiking levels (three replicates for each) in the matrix. Good recoveries were observed for all of the analytes and ranged between 70.6% and 93.5%, with relative standard deviations of less than 10%. Calibration curves were linear over the calibration ranges for all the analytes with r(2)≥ 0.998. Limits of detection ranged from 0.02 to 0.05 mg kg(-1), whereas limits of quantitation ranged from 0.06 to 0.16 mg kg(-1) for dinotefuran and its metabolites. The method was successfully applied to real samples, where dinotefuran and UF residues were found in the field-incurred melon samples. Residues were confirmed via LC-tandem mass spectrometry (LC-MS/MS) in positive-ion electrospray ionisation (ESI(+)) mode. Copyright © 2012 Elsevier Ltd. All rights reserved.
Hurst, Jerod J; Wallace, Josh S; Aga, Diana S
2018-04-01
Ionophore antimicrobials are heavily used in the livestock industries, both for preventing animal infection by coccidia protozoa and for increasing feed efficiency. Ionophores are excreted mostly unmetabolized and are released into the environment when manure is land-applied to fertilize croplands. Here, an analytical method was optimized to study the occurrences of five ionophore residues (monensin, lasalocid, maduramycin, salinomycin, and narasin) in dairy manure after solid-liquid separation and further treatment of the liquid manure by a membrane-based treatment system. Ionophore residues from the separated solid manure (dewatered manure) and suspended solids of manure slurry samples were extracted using ultrasonication with methanol, followed by sample clean-up using solid phase extraction (SPE) and subsequent analysis via liquid chromatography-tandem mass spectrometry (LC-MS/MS). The use of an ethyl acetate and methanol (1:1 v:v) mixture as an SPE eluent resulted in higher recoveries and lower method quantitation limits (MQL), when compared to using methanol. Overall recoveries from separated solid manure ranged from 73 to 134%. Liquid manure fractions were diluted with Nanopure™ water and cleaned up using SPE, where recoveries ranged from 51 to 100%. The developed extraction and LC-MS/MS methods were applied to analyze dairy manure samples subjected to an advanced manure treatment process involving a membrane-based filtration step (reverse osmosis). Monensin and lasalocid were detected at higher concentrations in the suspended solid fractions (4.40-420 ng/g for lasalocid and 85-1950 ng/g for monensin) compared to the liquid fractions (
Determination of human pharmaceuticals in pre- and post-sewage treatment
NASA Astrophysics Data System (ADS)
Tahrim, Nurfaizah Abu; Abdullah, Md. Pauzi; Aziz, Yang Farina Abdul
2013-11-01
In this present work, an analytical method based on solid phase extraction (SPE) followed by liquid chromatography-time-of-flight mass spectrometry (LC-TOF-MS) in positive electrospray ionisation mode was successfully applied to real samples for the determination of human pharmaceuticals in pre- and post-sewage treatment samples. The ten target compounds selected in this study include acetaminophen, theophylline, caffeine, metoprolol, sulfamethoxazole, carbamazepine, prednisolone, ketoprofen, norgestrel and simvastatin. Acetaminophen, theophylline and caffeine were present at all five raw sewage samples. In addition, this work provides the first report on the investigation and detection of theophylline in sewage treatment plant (STP) samples in Malaysia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Xueyun; Wojcik, Roza; Zhang, Xing
Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. IMS alone is useful, but its coupling with mass spectrometry (MS) and front-end separations has been extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information in biological and environmental sample analyses. Multiple studies in disease screening and environmental evaluations have even shown these IMS-based multidimensional separations extract information not possible with each technique individually. This review highlights 3-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography (GC),more » supercritical fluid chromatography (SFC), liquid chromatography (LC), solid phase extractions (SPE), capillary electrophoresis (CE), field asymmetric ion mobility spectrometry (FAIMS), and microfluidic devices. The origination, current state, various applications, and future capabilities for these multidimensional approaches are described to provide insight into the utility and potential of each technique.« less
Vidal, J L Martínez; Vega, A Belmonte; López, F J Sánchez; Frenich, A Garrido
2004-10-01
A method has been developed for the simultaneous determination of paraquat (PQ), deiquat (DQ), chlormequat (CQ) and mepiquat (MQ) in water samples by liquid chromatography (LC) coupled with electrospray ionization mass spectrometry (MS). The LC separations of the target compounds, as well as their MS parameters, were optimized in order to improve selectivity and sensitivity. Separation was carried out in a Xterra C8 column, using as mobile phase methanol-heptafluorobutyric acid (HFBA) in isocratic mode. The molecular ion was selected for the quantitation in selected ion monitoring (SIM) mode. Off-line solid-phase extraction (SPE) was applied with silica cartridges in order to preconcentrate the compounds from waters. Detection limits were in the range 0.02-0.40 microg l(-1). Recovery range varied between 89 and 99.5% with precision values lower than 6%. The method has been applied successfully to the analysis of both surface and groundwater samples from agricultural areas of Andalusia (Spain), using well defined internal quality control (IQC) criteria. The results revealed the presence of deiquat and paraquat in some samples.
Al-Sammak, Maitham Ahmed; Hoagland, Kyle D; Snow, Daniel D; Cassada, David
2013-12-15
Blue-green algae, also known as cyanobacteria, can produce several different groups of toxins in the environment including hepatotoxins (microcystins), neurotoxic non-protein amino acids β-methylamino-l-alanine (BMAA), and 2,4-diaminobutyric (DABA), as well as the bicyclic amine alkaloid anatoxin-a. Few studies have addressed the methods necessary for an accurate determination of cyanotoxins in environmental samples, and none have been published that can detect these cyanotoxins together in a single sample. Cyanotoxins occur in a wide range of environmental samples including water, fish, and aquatic plant samples. Using polymeric cation exchange solid phase extraction (SPE) coupled with liquid chromatography and fluorescence detection (HPLC/FD), and liquid chromatography ion trap tandem mass spectrometry (LC/MS/MS), these compounds can for the first time be simultaneously quantified in a variety of environmental sample types. The extraction method for biological samples can distinguish bound and free cyanotoxins. Detection limits for water ranged from 5 to 7 μg/L using HPLC/FD, while detection limits for and LC/MS were in the range of 0.8-3.2 μg/L. Copyright © 2013 Elsevier Ltd. All rights reserved.
Asghar, Muhammad Ali; Zhu, Qingxin; Sun, Shutang; Peng, Yue'e; Shuai, Qin
2018-04-20
In this study we developed a systematic method for suspect screening and target quantification of the human pharmaceutical residues in water, via solid phase extraction (SPE) followed by liquid chromatography-high resolution mass spectrometry (LC-HRMS). We then proceeded to study the occurrences and distribution of the pharmaceuticals in the surface waters of Wuhan, China, by analyzing water samples from lakes, rivers and municipal sewage. Initially, 33 human pharmaceuticals were identified from East Lake without using purchasing standards. Of these, 29 were later confirmed by using standards, and quantified using the aforementioned SPE pretreatment method and LC-HRMS analysis in full MS scan mode. The 29 compounds included 8 antibiotics, 9 metabolites, and 12 miscellaneous pharmaceuticals. The highest proportions of pharmaceutical residues were detected downstream of the Yangtze River and in the lakes close to the central city. Metformin, cotinine, and trans-3-hydroxy cotinine, were frequently encountered in all the surface water samples. High concentrations (>120 ng/l) of caffeine, metformin, theobromine, and valsartan were detected in the surface water samples; the removal rates of these compounds in the municipal sewage treatment plant were also high. In contrast, although the concentrations of 4-AAA and metoprolol acid in the surface water were high, the removal rates of these residues in the sewage treatment plant were low. Copyright © 2018. Published by Elsevier B.V.
Principles and Applications of Liquid Chromatography-Mass Spectrometry in Clinical Biochemistry
Pitt, James J
2009-01-01
Liquid chromatography-mass spectrometry (LC-MS) is now a routine technique with the development of electrospray ionisation (ESI) providing a simple and robust interface. It can be applied to a wide range of biological molecules and the use of tandem MS and stable isotope internal standards allows highly sensitive and accurate assays to be developed although some method optimisation is required to minimise ion suppression effects. Fast scanning speeds allow a high degree of multiplexing and many compounds can be measured in a single analytical run. With the development of more affordable and reliable instruments, LC-MS is starting to play an important role in several areas of clinical biochemistry and compete with conventional liquid chromatography and other techniques such as immunoassay. PMID:19224008
Alves, Claudete; Santos-Neto, Alvaro J; Fernandes, Christian; Rodrigues, José C; Lanças, Fernando M
2007-10-01
Solid-phase microextraction coupled to liquid chromatography and mass spectrometry (SPME-LC-MS) was used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. SPME was performed by direct extraction on a PDMS/DVB (60 microm) coated fiber, employing a stirring rate of 1200 rpm for 30 min, pH 11.0, and temperature of 30 degrees C. Drug desorption was carried out by exposing the fiber to the liquid chromatography mobile phase for 20 min, using a labmade SPME-LC interface at 50 degrees C. The main variables experimentally influencing LC-MS response were evaluated and mathematically modeled. A rational optimization with fewer experiments was achieved using a factorial design approach. The constructed empirical models were adjusted with 96-98% of explained deviation allowing an adequate data set comprehension. The chromatographic separation was realized using an RP-18 column (150 mm x 2.1 mm, 5 microm particles) and ammonium acetate buffer (0.01 mol/l, pH 5.50) : acetonitrile (50 : 50 v/v) as mobile phase. Low detection levels were achieved with electrospray interface (0.1 ng/ml). The developed method showed specificity, linearity, precision, and limit of quantification adequate to assay tricyclic antidepressant drugs in plasma.
François, Isabelle; Pereira, Alberto dos Santos; Sandra, Pat
2010-06-01
The separation of the triacylglycerols in fish oil was performed by comprehensive and off-line supercritical fluid chromatography combined with RP-LC. The first dimension consisted of two serially coupled silver-ion (SI)-loaded columns operated with a supercritical mobile phase (supercritical fluid chromatography, SFC) in both the cases, whereas the second dimension was performed in non-aqueous RP mode (NARP-LC) on a 10-cm monolithic octadecyl silica (ODS) or a 45-cm long ODS column packed with 1.8 microm particles for the comprehensive and off-line separations, respectively. Despite the outstanding performance of the SI-SFC x NARP-LC interface, the high complexity of the sample rendered the online separation far from complete. The off-line approach gave much better separation mainly because of the higher peak capacity of the second-dimension column, but even in this case, the use of MS was mandatory to elucidate the different triacylglycerols in fish oil. The disadvantage of the off-line procedure was the long analysis time.
Schermerhorn, Patricia G; Golden, Paul E; Krynitsky, Alexander J; Leimkuehler, William M
2005-01-01
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed for the determination of 14 parent triazole fungicides and 8 of their metabolites found in apples, peaches, flour, raw water, and tap water. The triazole fungicides chosen for this multiresidue method development project included propiconazole, fenbuconazole and its RH-9129 and RH-9130 metabolites, cyproconazole, difenoconazole, tebuconazole and its HWG 2061 metabolite, hexaconazole, bromuconazole (both stereoisomers), epoxiconazole, tetraconazole, triticonazole and its RPA-404886 and RPA-406341 metabolites, triadimefon, triadimenol, and myclobutanil. Of special concern to the U.S. Environmental Protection Agency were the metabolites common to all triazole fungicides: free triazole, 1,2,4-triazole (T), and its 2 conjugates: triazolylalanine (TA) and triazolylacetic acid (TAA). These metabolites were the primary focus of this project. All samples we cleaned up by a combination of C18 solid-phase extraction (SPE), mixed-mode cationic SPE, and mixed-mode anionic SPE columns. A triple-stage quadrupole mass spectrometer, equipped with electrospray ionization in the positive-ion mode, was used to determine the compounds of interest. T, TA, and TAA were quantitated using isotopically labeled internal standards (IS), in which the 1,2,4-triazole ring had been synthesized by using 13C and 15N (IS_T, IS_TA, and IS_TAA). These isotopically labeled internal standards were necessary to correct for matrix effects. The T, TA, and TAA metabolites were quantitated at the 25-50 parts-per-billion (ppb) level in food commodities and at 0.50 ppb in water. Recoveries were 70-101% from apples, 60-121% from peaches, 57-118% from flour, 75-99% from raw water, and 79-99% from tap water.
Polymer Analysis by Liquid Chromatography/Electrospray Ionization Time-of-Flight Mass Spectrometry.
Nielen, M W; Buijtenhuijs, F A
1999-05-01
Hyphenation of liquid chromatography (LC) techniques with electrospray ionization (ESI) orthogonal acceleration time-of-flight (oa-TOF) mass spectrometry (MS) provides both MS-based structural information and LC-based quantitative data in polymer analysis. In one experimental setup, three different LC modes are interfaced with MS: size-exclusion chromatography (SEC/MS), gradient polymer elution chromatography (GPEC/MS), and liquid chromatography at the critical point of adsorption (LCCC/MS). In SEC/MS, both absolute mass calibration of the SEC column based on the polymer itself and determination of monomers and end groups from the mass spectra are achieved. GPEC/MS shows detailed chemical heterogeneity of the polymer and the chemical composition distribution within oligomer groups. In LCCC/MS, the retention behavior is primarily governed by chemical heterogeneities, such as different end group functionalities, and quantitative end group calculations can be easily made. The potential of these methods and the benefit of time-of-flight analyzers in polymer analysis are discussed using SEC/MS of a polydisperse poly(methyl methacrylate) sample, GPEC/MS of dipropoxylated bisphenol A/adipic acid polyester resin, LCCC/MS of alkylated poly(ethylene glycol), and LCCC/MS of terephthalic acid/neopentyl glycol polyester resin.
Verplaetse, Ruth; Henion, Jack
2016-01-01
Opioids are well known, widely used painkillers. Increased stability of opioids in the dried blood spot (DBS) matrix compared to blood/plasma has been described. Other benefits provided by DBS techniques include point-of-care collection, less invasive micro sampling, more economical shipment, and convenient storage. Current methodology for analysis of micro whole blood samples for opioids is limited to the classical DBS workflow, including tedious manual punching of the DBS cards followed by extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. The goal of this study was to develop and validate a fully automated on-line sample preparation procedure for the analysis of DBS micro samples relevant to the detection of opioids in finger prick blood. To this end, automated flow-through elution of DBS cards was followed by on-line solid-phase extraction (SPE) and analysis by LC-MS/MS. Selective, sensitive, accurate, and reproducible quantitation of five representative opioids in human blood at sub-therapeutic, therapeutic, and toxic levels was achieved. The range of reliable response (R(2) ≥0.997) was 1 to 500 ng/mL whole blood for morphine, codeine, oxycodone, hydrocodone; and 0.1 to 50 ng/mL for fentanyl. Inter-day, intra-day, and matrix inter-lot accuracy and precision was less than 15% (even at lower limits of quantitation (LLOQ) level). The method was successfully used to measure hydrocodone and its major metabolite norhydrocodone in incurred human samples. Our data support the enormous potential of DBS sampling and automated analysis for monitoring opioids as well as other pharmaceuticals in both anti-doping and pain management regimens. Copyright © 2015 John Wiley & Sons, Ltd.
Boix, C; Ibáñez, M; Fabregat-Safont, D; Morales, E; Pastor, L; Sancho, J V; Sánchez-Ramírez, J E; Hernández, F
2016-01-01
In this work, two analytical methodologies based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) were developed for quantification of emerging pollutants identified in sewage sludge after a previous wide-scope screening. The target list included 13 emerging contaminants (EC): thiabendazole, acesulfame, fenofibric acid, valsartan, irbesartan, salicylic acid, diclofenac, carbamazepine, 4-aminoantipyrine (4-AA), 4-acetyl aminoantipyrine (4-AAA), 4-formyl aminoantipyrine (4-FAA), venlafaxine and benzoylecgonine. The aqueous and solid phases of the sewage sludge were analyzed making use of Solid-Phase Extraction (SPE) and UltraSonic Extraction (USE) for sample treatment, respectively. The methods were validated at three concentration levels: 0.2, 2 and 20 μg L(-1) for the aqueous phase, and 50, 500 and 2000 μg kg(-1) for the solid phase of the sludge. In general, the method was satisfactorily validated, showing good recoveries (70-120%) and precision (RSD < 20%). Regarding the limit of quantification (LOQ), it was below 0.1 μg L(-1) in the aqueous phase and below 50 μg kg(-1) in the solid phase for the majority of the analytes. The method applicability was tested by analysis of samples from a wider study on degradation of emerging pollutants in sewage sludge under anaerobic digestion. The key benefits of these methodologies are: • SPE and USE are appropriate sample procedures to extract selected emerging contaminants from the aqueous phase of the sewage sludge and the solid residue. • LC-MS/MS is highly suitable for determining emerging contaminants in both sludge phases. • Up to our knowledge, the main metabolites of dipyrone had not been studied before in sewage sludge.
Verplaetse, Ruth; Henion, Jack
2016-07-05
A workflow overcoming microsample collection issues and hematocrit (HCT)-related bias would facilitate more widespread use of dried blood spots (DBS). This report describes comparative results between the use of a pipet and a microfluidic-based sampling device for the creation of volumetric DBS. Both approaches were successfully coupled to HCT-independent, fully automated sample preparation and online liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis allowing detection of five stimulants in finger prick blood. Reproducible, selective, accurate, and precise responses meeting generally accepted regulated bioanalysis guidelines were observed over the range of 5-1000 ng/mL whole blood. The applied heated flow-through solvent desorption of the entire spot and online solid phase extraction (SPE) procedure were unaffected by the blood's HCT value within the tested range of 28.0-61.5% HCT. Enhanced stability for mephedrone on DBS compared to liquid whole blood was observed. Finger prick blood samples were collected using both volumetric sampling approaches over a time course of 25 h after intake of a single oral dose of phentermine. A pharmacokinetic curve for the incurred phentermine was successfully produced using the described validated method. These results suggest that either volumetric sample collection method may be amenable to field-use followed by fully automated, HCT-independent DBS-SPE-LC-MS/MS bioanalysis for the quantitation of these representative controlled substances. Analytical data from DBS prepared with a pipet and microfluidic-based sampling devices were comparable, but the latter is easier to operate, making this approach more suitable for sample collection by unskilled persons.
Guan, Fuyu; Robinson, Mary A
2017-09-08
The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be retrospectively analyzed for peptides unknown at the time of sample analysis. It is the first generic analytical method for comprehensive detection of multitudinous exogenous peptides in biological samples, to the authors' knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.
MicroSPE-nanoLC-ESI-MS/MS Using 10-μm-i.d. Silica-Based Monolithic Columns for Proteomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Quanzhou; Page, Jason S.; Tang, Keqi
2007-01-01
Silica-based monolithic narrow bore capillary columns (25 cm x 10 µm i.d.) with an integrated nanoESI emitter has been developed to provide high quality and robust microSPE-nanoLC-ESI-MS analyses. The integrated nanoESI emitter adds no dead volume to the LC separation, allowing stable electrospray performance to be obtained at flow rates of ~10 nL/min. In an initial application we identified 5510 unique peptides covering 1443 distinct Shewanella oneidensis proteins from a 300 ng tryptic digest sample in a single 4-h LC-MS/MS analysis using a linear ion trap MS (LTQ). We found the use of an integrated monolithic ESI emitter provided enhancedmore » resistance to clogging and good run-to-run reproducibility.« less
NASA Astrophysics Data System (ADS)
Watanabe, Kentaro; Taniguchi, Tatsuhiko; Sakane, Shunya; Aoki, Shunsuke; Suzuki, Takeyuki; Fujita, Takeshi; Nakamura, Yoshiaki
2017-05-01
Si-based epitaxial β-FeSi2 thin films are attractive as materials for on-chip thermoelectric power generators. We investigated the structure, crystallinity, and thermoelectric properties of β-FeSi2 thin films epitaxially grown on Si(111) substrates by using three different techniques: conventional reactive deposition epitaxy followed by molecular beam epitaxy (RDE+MBE), solid phase epitaxy (SPE) based on codeposition of Fe and Si presented previously, and SPE followed by MBE (SPE+MBE) presented newly by this work. Their epitaxial growth temperatures were fixed at 530 °C for comparison. RDE+MBE thin films exhibited high crystalline quality, but rough surfaces and rugged β-FeSi2/Si(111) interfaces. On the other hand, SPE thin films showed flat surfaces and abrupt β-FeSi2/Si(111) interfaces but low crystallinity. We found that SPE+MBE thin films realized crystallinity higher than SPE thin films, and also had flatter surfaces and sharper interfaces than RDE+MBE thin films. In SPE+MBE thin film growth, due to the initial SPE process with low temperature codeposition, thermal interdiffusion of Fe and Si was suppressed, resulting in the surface flatness and abrupt interface. Second high temperature MBE process improved the crystallinity. We also investigated thermoelectric properties of these β-FeSi2 thin films. Structural factors affecting the thermoelectric properties of RDE+MBE, SPE, and SPE+MBE thin films were investigated.
Castro-Vargas, Henry I; Baumann, Wolfram; Parada-Alfonso, Fabián
2016-07-01
In the present study we report the characterization of benzylglucosinolate (BG) isolated from papaya (Carica papaya L.) seeds. A methanolic extract was fractionated and further purified by solid phase extraction (SPE). It was analyzed by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS), and nuclear magnetic resonance spectroscopy ((1) H and (13) C-NMR) as well, and the target compound BG was identified by these two techniques. The effect of BG on lipid oxidation in edible vegetable oil (EO) was shown by observing some lipid oxidation products (linoleic acid hydroperoxides, LHP; hexanal, HEX; nonanal, NON; thiobarbituric acid reactives species, TBARS). BG reduced lipid oxidation production in EO by over 80%, as compared to a control sample and in this way has proved to be a useful antioxidant, even more effective than some antioxidants used by food industry. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Shanshan; Bian, Zhaoyang; Yang, Fei; Li, Zhonghao; Fan, Ziyan; Zhang, Hongfei; Wang, Ying; Zhang, Yange; Tang, Gangling
2015-01-01
A method to determine residues of the three acid herbicides, 2,4,5-trichlorophenoxyacetic acid, 2,4-dichlorophenoxyacetic acid, and 3,6-dichloro-2-methoxybenzoic acid (dicamba), in tobacco using LC/MS/MS is presented. Because these herbicide residues in tobacco might exist in different forms (free acid, salt, and ester), tobacco samples were first pretreated by alkaline hydrolysis and then the pH was adjusted in order to convert the residues completely to their free acid forms. Dichloromethane extraction and dispersive SPE using C18 sorbent were carried out before LC/MS/MS analysis, and quantification was performed using the internal standard method. Linearity was good for all analytes (R(2) ≥ 0.999) in the concentration range of 0.02 to 0.5 mg/kg. LODs were below 0.05 mg/kg. Recoveries ranged from 80.4 to 93.5%, and RSD was below 10%. This simple, efficient, and sensitive method can be applied to the determination of residues of the three acid herbicides in tobacco.
Analytical methods in environmental effects-directed investigations of effluents.
Hewitt, L Mark; Marvin, Chris H
2005-05-01
Effluent discharges are released into aquatic environments as complex mixtures for which there is commonly either no knowledge of the toxic components or a lack of understanding of how known toxicants interact with other effluent components. Effects-directed investigations consist of chemical extraction and iterative fractionation steps directed by a biological endpoint that is designed to permit the identification or characterization of the chemical classes or compounds in a complex mixture responsible for the observed biological activity. Our review of the literature on effects-directed analyses of effluents for non-mutagenic as well as mutagenic endpoints showed that common extraction and concentration methods have been used. Since the mid-1980s, the methods have evolved from the use of XAD resins to C18 solid-phase extraction (SPE). Blue cotton, blue rayon, and blue chitin have been used specifically for investigations of mutagenic activity where polycyclic compounds were involved or suspected. After isolation, subsequent fractionations have been accomplished using SPE or a high-pressure liquid chromatography (HPLC) system commonly fitted with a C18 reverse-phase column. Substances in active fractions are characterized by gas chromatography/mass spectrometry (GC-MS) and/or other spectrometric techniques for identification. LC-MS methods have been developed for difficult-to-analyze polar substances identified from effects-directed studies, but the potential for LC-MS to identify unknown polar compounds has yet to be fully realized. Salmonella-based assays (some miniaturized) have been coupled with fractionation methods for most studies aimed at identifying mutagenic fractions and chemical classes in mixtures. Effects-directed investigations of mutagens have focused mostly on drinking water and sewage, whereas extensive investigations of non-mutagenic effects have also included runoff, pesticides, and pulp mill effluents. The success of effects-directed investigations should be based on a realistic initial objective of each project. Identification of chemical classes associated with the measured biological endpoint is frequently achievable; however, confirmation of individual compounds is much more difficult and not always a necessary goal of effects-directed chemical analysis.
Janda, Joachim; Nödler, Karsten; Brauch, Heinz-Jürgen; Zwiener, Christian; Lange, Frank T
2018-03-19
A simple and robust analytical method for the determination of perfluorinated carboxylic acids (PFCAs) with C 2 to C 8 chains, based on solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS), was developed, validated and applied to tap water, groundwater and surface water. Two stationary phases for LC (Obelisc N and Kinetex C 18 ) and two materials with weak anion-exchange properties for SPE (Strata X-AW and Oasis WAX) were evaluated. Robust separation and retention was achieved with the reversed phase column and an acidic eluent. Quantitative extraction recoveries were generally achieved for PFCAs with C > 3, but extraction efficiencies were different for the two shortest chained analytes: 36 to 114% of perfluoropropanoate (PFPrA) and 14 to 99% of trifluoroacetate (TFA) were recovered with Strata X-AW, while 93 to 103% of PFPrA and 40 to 103% of TFA were recovered with Oasis WAX. The sample pH was identified as a key parameter in the extraction process. One-step elution-filtration was introduced in the workflow, in order to remove sorbent particles and minimise sample preparation steps. Validation resulted in limits of quantification for all PFCAs between 0.6 and 26 ng/L. Precision was between 0.7 and 15% and mean recoveries ranged from 83 to 107%. In groundwater samples from sites impacted by per- and polyfluoroalkyl substances (PFASs), PFCA concentrations ranged from 0.056 to 2.2 μg/L. TFA and perfluorooctanoate were the predominant analytes. TFA, however, revealed a more ubiquitous occurrence and was found in concentrations between 0.045 and 17 μg/L in drinking water, groundwater and surface water, which were not impacted by PFASs.
Farhan, Nashid; Fitzpatrick, Sean; Shim, Yun M; Paige, Mikell; Chow, Diana Shu-Lian
2016-09-05
4-Methoxydiphenylmethane (4-MDM), a selective augmenter of Leukotriene A4 Hydrolase (LTA4H), is a new anti-inflammatory compound for potential treatment of chronic obstructive pulmonary disease (COPD). Currently, there is no liquid chromatography tandem mass spectrometric (LC-MS/MS) method for the quantification of 4-MDM. A major barrier for developing the LC-MS/MS method is the inability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to ionize 4-MDM due to its hydrophobicity and lack of any functional group for ionization. With the advent of atmospheric pressure photoionization (APPI) technique, many hydrophobic compounds have been demonstrated to ionize by charge transfer reactions. In this study, a highly sensitive ultrapressure liquid chromatography tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for the quantifications of 4-MDM in rat plasma has been developed and validated. 4-MDM was extracted from the plasma by solid phase extraction (SPE) and separated chromatographically using a reverse phase C8 column. The photoionization (PI) was achieved by introducing anisole as a dopant to promote the reaction of charge transfer. The assay with a linear range of 5 (LLOQ)-400ngmL(-1) met the regulatory requirements for accuracy, precision and stability. The validated assay was employed to quantify the plasma concentrations of 4-MDM after an oral dosing in Sprague Dawley (SD) rats. Copyright © 2016 Elsevier B.V. All rights reserved.
Review of online coupling of sample preparation techniques with liquid chromatography.
Pan, Jialiang; Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke
2014-03-07
Sample preparation is still considered as the bottleneck of the whole analytical procedure, and efforts has been conducted towards the automation, improvement of sensitivity and accuracy, and low comsuption of organic solvents. Development of online sample preparation techniques (SP) coupled with liquid chromatography (LC) is a promising way to achieve these goals, which has attracted great attention. This article reviews the recent advances on the online SP-LC techniques. Various online SP techniques have been described and summarized, including solid-phase-based extraction, liquid-phase-based extraction assisted with membrane, microwave assisted extraction, ultrasonic assisted extraction, accelerated solvent extraction and supercritical fluids extraction. Specially, the coupling approaches of online SP-LC systems and the corresponding interfaces have been discussed and reviewed in detail, such as online injector, autosampler combined with transport unit, desorption chamber and column switching. Typical applications of the online SP-LC techniques have been summarized. Then the problems and expected trends in this field are attempted to be discussed and proposed in order to encourage the further development of online SP-LC techniques. Copyright © 2014 Elsevier B.V. All rights reserved.
Application of LC-MS/MS MRM to Determine Staphylococcal Enterotoxins (SEB and SEA) in Milk.
Andjelkovic, Mirjana; Tsilia, Varvara; Rajkovic, Andreja; De Cremer, Koen; Van Loco, Joris
2016-04-20
Staphylococcus aureus is one of the important aetiological agents of food intoxications in Europe and can cause gastro-enteritis through the production of various staphylococcal enterotoxins (SEs) in foods. Due to their stability and ease of production and dissemination, some SEs have also been studied as potential agents for bioterrorism. Therefore, specific and accurate analytical tools are required to detect and quantify SEs. Online solid-phase extraction liquid chromatography electrospray ionization tandem mass spectrometry (online SPE-LC-ESI-MS/MS) based on multiple reaction monitoring (MRM) was used to detect and quantify two types of SE (A and B) spiked in milk and buffer solution. SE extraction and concentration was performed according to the European Screening Method developed by the European Reference Laboratory for Coagulase Positive Staphylococci. Trypsin digests were screened for the presence of SEs using selected proteotypic heavy-labeled peptides as internal standards. SEA and SEB were successfully detected in milk samples using LC-MS/MS in MRM mode. The selected SE peptides were proteotypic for each toxin, allowing the discrimination of SEA and SEB in a single run. The detection limit of SEA and SEB was approximately 8 and 4 ng/g, respectively.
Zhang, Hong-Chang; Yu, Xue-jun; Yang, Wen-chao; Peng, Jin-feng; Xu, Ting; Yin, Da-Qiang; Hu, Xia-lin
2011-10-15
A novel analytical method employing MCX (mixed-mode cationic exchange) based solid phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed to detect 31 endocrine-disrupting compounds (EDCs) in surface water samples simultaneously. The target EDCs belong to five classes, including seven estrogens, eight androgens, six progesterones, five adrenocortical hormones and five industrial compounds. In order to simultaneously concentrate the target EDCs and eliminate matrix interferences in the water samples, MCX SPE cartridges were employed for SPE, and then followed by a simple and highly efficient three-step sequential elution procedure. Two electrospray ionization (ESI) detection modes, positive (ESI+) and (ESI-), were optimized for HPLC-MS/MS analysis to obtain the highest sensitivity for all the EDCs. The limits of detection (LODs) were 0.02-1.9 ng L(-1), which are lower than or comparable to these reported in references. Wide linear ranges (LOD-100 ng L(-1) for ESI+ mode, and LOD-200 ng L(-1) for ESI- mode) were obtained with determination coefficients (R(2)) higher than 0.99 for all the compounds. With five internal standards, good recoveries (84.4-103.0%) of all the target compounds were obtained in selected surface water samples. The developed method was successfully applied to investigate the EDCs occurrence in the surface water of Shanghai by analyzing surface water samples from 11 sites. The results showed that nearly all the target compounds (30 in 31) were present in the surface water samples of Shanghai, of which three industrial compounds (4-t-OP, BPA, and BPF) showed the highest concentrations (median concentrations were 11.88-23.50 ng L(-1)), suggesting that industrial compounds were the dominating EDCs in the surface water of Shanghai, and much more attention should be paid on these compounds. Our present research demonstrated that SPE with MCX cartridges combined with HPLC-MS/MS was convenient, efficient and reliable for multiclass analysis of EDCs in surface water. Copyright © 2011 Elsevier B.V. All rights reserved.
Schrack, S; Hohl, C; Schwack, W
2016-11-18
Sterol oxidation products (SOPs) are linked to several toxicological effects. Therefore, investigation of potential dietary uptake sources particularly food of animal origin has been a key issue for these compounds. For the simultaneous determination of oxysterols from cholesterol, phytosterols, dihydrolanosterol and lanosterol in complex cosmetic matrices, planar solid phase extraction (pSPE) was applied as clean-up tool. SOPs were first separated from more non-polar and polar matrix constituents by normal phase thin-layer chromatography and then focussed into one target zone. Zone extraction was performed with the TLC-MS interface, followed by gas chromatography-mass spectrometry analysis. pSPE showed to be effective for cleaning up cosmetic samples as sample extracts were free of interferences, and gas chromatographic columns did not show any signs of overloading. Recoveries were between 86 and 113% with relative standard deviations of below 10% (n=6). Results of our market survey in 2016 showed that some cosmetics with ingredients of plant origin contained phytosterol oxidation products (POPs) in the low ppm range and therefore in line with levels reported for food. In lanolin containing products, total SOPs levels (cholesterol oxidation products (COPs), lanosterol oxidation products (LOPs), dihydrolanosterol oxidation products (DOPs)) being in the low percent range exceeded reported levels for food by several orders of magnitudes. Copyright © 2016 Elsevier B.V. All rights reserved.
Microfluidic liquid chromatography system for proteomic applications and biomarker screening.
Lazar, Iulia M; Trisiripisal, Phichet; Sarvaiya, Hetal A
2006-08-01
A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p < 0.001, and of 5 proteins that are known to be cancer-specific biomarkers, demonstrating thus the potential applicability of these chips for future high-throughput biomarker screening applications.
Hioki, Yusaku; Tanimura, Ritsuko; Iwamoto, Shinichi; Tanaka, Koichi
2014-03-04
Nanoflow liquid chromatography (nano-LC) is an essential technique for highly sensitive analysis of complex biological samples, and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is advantageous for rapid identification of proteins and in-depth analysis of post-translational modifications (PTMs). A combination of nano-LC and MALDI-MS (nano-LC/MALDI-MS) is useful for highly sensitive and detailed analysis in life sciences. However, the existing system does not fully utilize the advantages of each technique, especially in the interface of eluate transfer from nano-LC to a MALDI plate. To effectively combine nano-LC with MALDI-MS, we integrated a nano-LC column and a deposition probe for the first time (column probe) and incorporated it into a nano-LC/MALDI-MS system. Spotting nanoliter eluate droplets directly from the column onto the MALDI plate prevents postcolumn diffusion and preserves the chromatographic resolution. A DHB prespotted plate was prepared to suit the fabricated column probe to concentrate the droplets of nano-LC eluate. The performance of the advanced nano-LC/MALDI-MS system was substantiated by analyzing protein digests. When the system was coupled with multidimensional liquid chromatography (MDLC), trace amounts of glycopeptides that spiked into complex samples were successfully detected. Thus, a nano-LC/MALDI-MS direct-spotting system that eliminates postcolumn diffusion was constructed, and the efficacy of the system was demonstrated through highly sensitive analysis of the protein digests or spiked glycopeptides.
Buiarelli, Francesca; Giannetti, Luigi; Jasionowska, Renata; Cruciani, Claudia; Neri, Bruno
2010-07-15
Nandrolone (19-nortestosterone) is an androgenic anabolic steroid illegally used as a growth-promoting agent in animal breeding and as a performance enhancer in athletics. Therefore, its use was officially banned in 1974 by the Medical Commission of the International Olympic Committee (IOC). Following nandrolone administration, the main metabolites in humans are 19-norandrosterone, 19-norethiocolanolone and 19-norepiandrosterone, and their presence in urine is the basis of detecting its abuse. The present work was undertaken to determine, in human urine, nandrolone metabolites (phase I and phase II) by developing and comparing multiresidue liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) methods. A double extraction by solid-phase extraction (SPE) was necessary for the complete elimination of the interfering compounds. The proposed methods were also tested on a real positive sample, and they allow us to determine the conjugated/free fractions ratio reducing the risk of false positive or misleading results and they should allow laboratories involved in doping control analysis to monitor the illegal use of steroids. The advantages of LC/MS/MS over GC/MS (which is the technique mainly used) include the elimination of the hydrolysis and derivatization steps: it is known that during enzymatic hydrolysis several steroids can be converted into related compounds and deconjugation is not always 100% effective. The validation parameters for the two methods were similar (limit of quantification (LOQ) <1 ng/mL and percentage coefficient of variance (CV%) <16.4), and both were able to confirm unambiguously all the analytes, thus confirming the validity of both techniques. Copyright 2010 John Wiley & Sons, Ltd.
Magda, Balázs; Dobi, Zoltán; Mészáros, Katalin; Szabó, Éva; Márta, Zoltán; Imre, Tímea; Szabó, Pál T
2017-06-05
The aim of this study was to develop a sensitive, reliable and high-throughput liquid chromatography - electrospray ionization - mass spectrometric (LC-ESI-MS/MS) method for the simultaneous quantitation of cortisol and cortisone in human saliva. Derivatization with 2-hydrazino-1-methylpyridine (HMP) was one of the most challenging aspects of the method development. The reagent was reacting with cortisol and cortisone at 60°C within 1h, giving mono- and bis-hydrazone derivatives. Investigation of derivatization reaction and sample preparation was detailed and discussed. Improvement of method sensitivity was achieved with charged derivatization and use of on-line solid phase extraction (on-line SPE). The lower limit of quantitation (LLOQ) was 5 and 10pg/ml for cortisol and cortisone, respectively. The developed method was subsequently applied to clinical laboratory measurement of cortisol and cortisone in human saliva. Copyright © 2017 Elsevier B.V. All rights reserved.
Ferrer-Aguirre, Alejandra; Romero-González, Roberto; Vidal, J L Martínez; Frenich, Antonia Garrido
2016-05-13
A simple and quick analytical method has been developed for the determination of pharmaceutical compounds in water. An on-line solid-phase extraction (SPE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been optimized to determine 7 contaminants of emerging concern in environmental waters at ngL(-1) levels. This procedure requires minimal sample handling and small sample volume (900μL) with a total running time of 18min. Several SPE parameters were evaluated and optimized in order to achieve a high sample throughput. Therefore sample volume, carryover and reusability of the cartridges were evaluated. Performance characteristics were evaluated and good linearity was obtained (R(2)>0.98). Recoveries were evaluated in spiked samples at three concentrations and the values ranged from 71 to 104%. Intra and inter-day precision was lower than 10 and 13% respectively. Limits of quantification were equal to or lower than 10ngL(-1), except for 1,7-dimethylxanthine (20ngL(-1)) and ibuprofen (50ngL(-1)). The method was applied to 20 environmental water samples, and ibuprofen was the compound most widely detected at concentrations up to 42.06μgL(-1), whereas the other compounds were detected in fewer samples at lower concentrations (up to 15.99μgL(-1)). Copyright © 2016 Elsevier B.V. All rights reserved.
Arias, Jean Lucas de Oliveira; Rombaldi, Caroline; Caldas, Sergiane Souza; Primel, Ednei Gilberto
2014-09-19
The clean-up step is essential to reduce interferences, improve quantification and help to maintain the integrity of the chromatographic system when working with complex matrices. In this study, alternative materials were evaluated as sorbents in the dispersive solid-phase extraction (D-SPE) for the determination and extraction of seventeen pesticides from rice paddy soil samples by the quick, easy, cheap, effective, rugged and safe (QuEChERS) method coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Chitin, chitosan, diatomaceous earth and PSA were compared in terms of extraction efficiency and matrix effect. The best results were achieved when chitosan was used. Quantification limits ranged from 0.1 to 100μgkg(-1). Calibration curves showed correlation coefficient values higher than 0.98. Results of accuracy and precision in the spiked soil samples between 60% and 120%, with a relative standard deviation lower than 20%, were reached for 15 out of 17 pesticides. The matrix effect was evaluated and only one compound was influenced by the matrix components, showing medium effect. Results showed that alternative materials are more effective and less expensive than traditional sorbents which have been usually employed, i.e., they may be used in the D-SPE step during the extraction of pesticides from rice paddy soils. Copyright © 2014 Elsevier B.V. All rights reserved.
Kuhlenbeck, Debbie L; Eichold, Thomas H; Hoke, Steven H; Baker, Timothy R; Mensen, Robert; Wehmeyer, Kenneth R
2005-01-01
An on-line liquid chromatography/tandem mass spectrometry (LC-MS/MS) procedure, using the Prospekt- 2 system, was developed and used for the determination of the levels of the active ingredients of cough/cold medications in human plasma matrix. The experimental configuration allows direct plasma injection by performing on- line solid phase extraction (SPE) on small cartridge columns prior to elution of the analyte(s) onto the analytical column and subsequent MS/MS detection. The quantitative analysis of three analytes with differing polarities, dextromethorphan (DEX), dextrorphan (DET) and guaifenesin (GG) in human plasma presented a significant challenge. Using stable-isotope-labeled internal standards for each analyte, the Prospekt-2 on-line methodology was evaluated for sensitivity, suppression, accuracy, precision, linearity, analyst time, analysis time, cost, carryover and ease of use. The lower limit of quantitation for the on-line SPE procedure for DEX, DET and GG was 0.05, 0.05 and 5.0 ng mL(-1), respectively, using a 0.1 mL sample volume. The linear range for DEX and DET was 0.05-50 ng mL(-1) and was 5-5,000 ng mL(-1) for GG. Accuracy and precision data for five different levels of QC samples were collected over three separate days. Accuracy ranged from 90% to 112% for all three analytes, while the precision, as measured by the %RSD, ranged from 1.5% to 16.0%
NASA Astrophysics Data System (ADS)
Mbukwa, Elbert A.; Msagati, Titus A. M.; Mamba, Bhekie B.
Harmful algal blooms (HABs) are increasingly becoming of great concern to water resources worldwide due to indiscriminate waste disposal habits resulting in water pollution and eutrophication. When cyanobacterial cells lyse (burst) they release toxins called microcystins (MCs) that are well known for their hepatotoxicity (causing liver damage) and have been found in eutrophic lakes, rivers, wastewater ponds and other water reservoirs. Prolonged exposure to low concentrated MCs are equally of health importance as they are known to be bioaccumulative and even at such low concentration do exhibit toxic effects to aquatic animals, wildlife and human liver cells. The application of common treatment processes for drinking water sourced from HABs infested reservoirs have the potential to cause algal cell lyses releasing low to higher amounts of MCs in finished water. Trace microcystins in water/tissue can be analyzed and quantified using Liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) following solid-phase extraction (SPE) sample clean-up procedures. However, extracting MCs from algal samples which are rich in chlorophyll pigments and other organic matrices the SPE method suffers a number of drawbacks, including cartridge clogging, long procedural steps and use of larger volumes of extraction solvents. We applied a supported liquid membrane (SLM) based technique as an alternative sample clean-up method for LC-ESI-MS analysis of MCs from both water and algal cells. Four (4) MC variants (MC-RR, -YR, -LR and -WR) from lyophilized cells of Microcystis aeruginosa and water collected from a wastewater pond were identified) and quantified using LC-ESI-MS following a SLM extraction and liquid partitioning step, however, MC-WR was not detected from water extracts. Within 45 min of SLM extraction all studied MCs were extracted and pre-concentrated in approximately 15 μL of an acceptor phase at an optimal pH 2.02 of the donor phase (sample). The highest total quantifiable intracellular and extracellular MCs were 37.039 ± 0.087 μg/g DW and 5.123 ± 0.018 μg/L, respectively. The concentrations of MC-RR were the highest from all samples studied recording maximum values of 21.579 ± 0.066 μg/g DW and 3.199 ± 0.012 μg/L for intracellular and extracellular quantities, respectively.
Slobodník, J; Oztezkizan, O; Lingeman, H; Brinkman, U A
1996-10-25
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram/l in surface water.
Talus, Eric S; Witt, Klaus E; Stoll, Dwight R
2015-01-23
Users of online comprehensive two-dimensional liquid chromatography (LCxLC) frequently acknowledge that the mechanical instability of HPLC columns installed in these systems, particularly in the second dimension, is a significant impediment to its use. Such instability is not surprising given the strenuous operating environment to which these columns are subjected, including the large number (thousands per day) of fast and large pressure pulses resulting from interface valve switches (on the timescale of tens of milliseconds) associated with very fast second dimension separations. There appear to be no published reports of systematic studies of the relationship between second dimension column lifetime and any of these variables. In this study we focused on the relationship between the lifetimes of commercially available columns and the pressure pulses observed at the inlet of the second dimension column that occur during the switching of the valve that interfaces the two dimensions of a LCxLC system. We find that the magnitude of the pressure drop at the inlet of the second dimension column during the valve switch, which may vary between 10 and 95% of the column inlet pressure, is dependent on valve switching speed and design, and has a dramatic impact on column lifetime. In the worst case, columns fail within the first few hours of use in an LCxLC system. In the best case, using a valve that exhibits much smaller pressure pulses, the same columns exhibit much improved lifetimes and have been used continuously under LCxLC conditions for several days with no degradation in performance. This result represents a first step in understanding the factors that affect second dimension column lifetime, and will significantly improve the usability of the LCxLC technique in general. Copyright © 2014 Elsevier B.V. All rights reserved.
Venkatramani, C J; Al-Sayah, Mohammad; Li, Guannan; Goel, Meenakshi; Girotti, James; Zang, Lisa; Wigman, Larry; Yehl, Peter; Chetwyn, Nik
2016-02-01
A new interface was designed to enable the coupling of reversed phase liquid chromatography (RPLC) and supercritical fluid chromatography (SFC). This online two-dimensional chromatographic system utilizing RPLC in the first dimension and SFC in the second was developed to achieve simultaneous achiral and chiral analysis of pharmaceutical compounds. The interface consists of an eight-port, dual-position switching valve with small volume C-18 trapping columns. The peaks of interest eluting from the first RPLC dimension column were effectively focused as sharp concentration pulses on small volume C-18 trapping column/s and then injected onto the second dimension SFC column. The first dimension RPLC separation provides the achiral purity result, and the second dimension SFC separation provides the chiral purity result (enantiomeric excess). The results are quantitative enabling simultaneous achiral, chiral analysis of compounds. The interface design and proof of concept demonstration are presented. Additionally, comparative studies to conventional SFC and case studies of the applications of 2D LC-SFC in pharmaceutical analysis is presented. Copyright © 2015 Elsevier B.V. All rights reserved.
Guo, Lin; Wang, Meng-meng; He, Min; Qiu, Fu-rong; Jiang, Jian
2015-04-01
A liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed to quantify ezetimibe (EZM) and its major glucuronide (ezetimibe glucuronide, EZM-G) in human plasma simultaneously. The analytes were purified by solid phase extraction (SPE) without hydrolysis. Separation of the analytes was achieved using acetonitrile-water (0.08% formic acid) (70:30, v/v) as the mobile phase at a flow rate of 0.8 mL/min on an Agilent Extend C18 column. The analytes were detected by LC-MS/MS using negative ionization in multiple reaction monitoring (MRM) mode. The mass transition pairs of m/z 408.4→271.0 and m/z 584.5→271.0 were used to detect EZM and EZM-G, respectively. The analytical method was linear over the concentration range of 0.1-20 ng/mL for EZM and 0.5-200 ng/mL for EZM-G. Within- and between-run precision for EZM was no more than 8.6% and 12.8%; and for EZM-G was no more than 9.0% and 8.7%, respectively. This method was reproducible and reliable, and was successfully used to analyze human plasma samples for application in a bioequivalence study. Copyright © 2015 Elsevier B.V. All rights reserved.
Bosco, Renato; Caser, Matteo; Vanara, Francesca; Scariot, Valentina
2013-11-20
Plant hormones play a crucial role in controlling plant growth and development. These groups of naturally occurring substances trigger physiological processes at very low concentrations, which mandate sensitive techniques for their quantitation. This paper describes a method to quantify endogenous (±)-2-cis-4-trans-abscisic acid, indole-3-acetic acid, indole-3-propionic acid, and indole-3-butyric acid. The method combines high-performance liquid chromatography (HPLC) with diode array and fluorescence detection in a single run. Hybrid tea rose 'Monferrato' matrices (leaves, petals, roots, seeds, androecium, gynoecium, and pollen) were used as references. Rose samples were separated and suspended in extracting methanol, after which (±)-2-cis-4-trans-abscisic acid and auxins were extracted by solvent extraction. Sample solutions were added first to cation solid phase extraction (SPE) cartridges and the eluates to anion SPE cartridges. The acidic hormones were bound to the last column and eluted with 5% phosphoric acid in methanol. Experimental results showed that this approach can be successfully applied to real samples and that sample preparation and total time for routine analysis can be greatly reduced.
Luque-Córdoba, D; Calderón-Santiago, M; Luque de Castro, M D; Priego-Capote, F
2018-08-01
Endocannabinoids are lipids with a key role in physiological processes such as the immune response or the metabolism. This involvement explains their association to pathologies such as cancer, obesity or multiple sclerosis. The determination of endocannabinoids constitutes a challenge for clinical laboratories due to the variety of biological matrices and the wide range of concentrations at which they can be found. This research deals with the comparison of three sample preparation strategies (viz., on-line SPE, off-line SPE for interferents removal, and protein precipitation) for subsequent LC-MS/MS analysis of 14 endocannabinoids and analogous compounds in serum. As a result, the on-line coupling between SPE and LC-MS/MS is proposed as the best approach for this determination. The proposed method allows full automation of the overall process, shortening of the analysis time, and avoidance of errors associated with sample preparation steps. The improvement in sensitivity and selectivity thus achieved allows obtaining quantification limits at the pg mL -1 level, which makes possible the application of the method for clinical studies. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Thibault, P.; Pleasance, S.; Laycock, M. V.; Mackay, R. M.; Boyd, R. K.
1991-12-01
An inseparable mixture of two cysteine proteinases, isolated from the digestive tract of the American lobster, was investigated by ionspray mass spectrometry (ISP-MS), using a combination of infusion of intact proteins with on-line liquid chromatography--mass spectrometry (LC--MS) and LC--MS--MS analyses of tryptic digests. These data were interpreted by comparisons with predictions from results of molecular cloning of cysteine-proteinase-encoding messenger RNA sequences previously isolated from the lobster hepatopancreas. Investigations of the numbers of free thiol groups and of disulfide bonds were made by measuring the molecular weights of the alkylated proteins with and without prior reduction of disulfide bonds, and comparison with the corresponding data for the native proteins. Identification of tyrptic fragment peptides containing cysteine residues was facilitated by comparing LC--MS analyses of tryptic digests of denatured and of denatured and alkylated proteins, since such tryptic peptides are subject to shifts in both mass and retention time upon reduction and alkylation. Confirmation of amino acid sequences was obtained from fragment ion spectra of each tryptic peptide (alkylated or not) as it eluted from the column. Acquisition of such on-line LC--MS data was possible through use of the entire effluent from a standard 1 mm high performance liquid chromatography (HPLC) column by an IonsSpray® LC--MS interface (pneumatically assisted electrospray).
Bruckner, C A; Ecker, S T; Synovec, R E
1997-09-01
A flame ionization detector (FID) is used to detect volatile organic compounds that have been separated by water-only reversed-phase liquid chromatography (WRP-LC). The mobile phase is 100% water at room temperature, without use of organic solvent modifiers. An interface between the LC and detector is presented, whereby a helium stream samples the vapor of volatile components from individual drops of the LC eluent, and the vapor-enriched gas stream is sent to the FID. The design of the drop headspace cell is simple because the water-only nature of the LC separation obviates the need to do any organic solvent removal prior to gas phase detection. Despite the absence of organic modifier, hydrophobic compounds can be separated in a reasonable time due to the low phase volume ratio of the WRP-LC columns. The drop headspace interface easily handles LC flows of 1 mL/min, and, in fact, compound detection limits are improved at faster liquid flow rates. The transfer efficiency of the headspace interface was estimated at 10% for toluene in water at 1 mL/min but varies depending on the volatility of each analyte. The detection system is linear over more than 5 orders of 1-butanol concentration in water and is able to detect sub-ppb amounts of o-xylene and other aromatic compounds in water. In order to analyze volatile and nonvolatile analytes simultaneously, the FID is coupled in series to a WRP-LC system with UV absorbance detection. WRP-LC improves UV absorbance detection limits because the absence of organic modifier allows the detector to be operated in the short-wavelength UV region, where analytes generally have significantly larger molar absorptivities. The selectivity the headspace interface provides for flame ionization detection of volatiles is demonstrated with a separation of 1-butanol, 1,1,2-trichloroethane (TCE), and chlorobenzene in a mixture of benzoic acid in water. Despite coelution of butanol and TCE with the benzoate anion, the nonvolatile benzoate anion does not appear in the FID signal, allowing the analytes of interest to be readily detected. The complementary selectivity of UV-visible absorbance detection and this implementation of flame ionization detection allows for the analysis of volatile and nonvolatile components of complex samples using WRP-LC without the requirement that all the components of interest be fully resolved, thus simplifying the sample preparation and chromatographic requirements. This instrument should be applicable to routine automated water monitoring, in which repetitive injection of water samples onto a gas chromatograph is not recommended.
Bladergroen, Marco R.; van der Burgt, Yuri E. M.
2015-01-01
For large-scale and standardized applications in mass spectrometry- (MS-) based proteomics automation of each step is essential. Here we present high-throughput sample preparation solutions for balancing the speed of current MS-acquisitions and the time needed for analytical workup of body fluids. The discussed workflows reduce body fluid sample complexity and apply for both bottom-up proteomics experiments and top-down protein characterization approaches. Various sample preparation methods that involve solid-phase extraction (SPE) including affinity enrichment strategies have been automated. Obtained peptide and protein fractions can be mass analyzed by direct infusion into an electrospray ionization (ESI) source or by means of matrix-assisted laser desorption ionization (MALDI) without further need of time-consuming liquid chromatography (LC) separations. PMID:25692071
Ding, X; Morrison, G; Dean, B; Hop, C E C A; Tobler, L; Percey, S; Meng, M; Reuschel, S; West, D A; Holden, S; Ware, J A
2012-03-05
A solid phase extraction (SPE) liquid chromatographic-tandem mass spectrometry (LC-MS/MS) method for the determination of GDC-0941 concentrations in human plasma has been developed and validated to support clinical development. An Oasis MCX 10mg 96-well SPE plate was used to extract plasma samples (50 μL) and the resulting extracts were analyzed using reverse-phase chromatography and mass spectrometer coupled with a turbo-ionspray interface. The method was validated over the calibration curve range 0.500-500 ng/mL with linear regression and 1/x(2) weighting. Within-run relative standard deviation (%RSD) ranged from 1.5 to 11.5%, while the between-run %RSD varied from 0.0 to 4.4%. The accuracy ranged from 96.0% to 110.0% of nominal for within-run and 98.0% to 108.0% of nominal for between-run at all concentrations including the LLOQ quality control at 0.500 ng/mL. Extraction recovery of GDC-0941 was between 79.0% and 86.2%. Stability of GDC-0941 was established in human plasma for 602 days at -70 °C and 598 days at -20°C, respectively, and established in reconstituted sample extracts for 167 h when stored at room temperature. Internal standard normalized matrix factor was 1.1, demonstrating that the use of the stable-labeled internal standard GDC-0941-d(8) effectively compensated observed matrix effect and resulting in no adverse impact on the quality of the data produced. This assay was used for the determination of GDC-0941 human plasma concentrations over a sufficient time period to determine pharmacokinetic parameters at relevant clinical doses. Copyright © 2011 Elsevier B.V. All rights reserved.
Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Centrich, Francesc
2012-01-01
A multiresidue method based on GC or LC and MS or MS/MS for the determination of 204 pesticides in diverse food matrixes of animal and plant origin is described. The method can include different stages of cleanup according to the chemical characteristics of each sample. Samples were extracted using accelerated solvent extraction. Those with a high fat content or that contained chlorophyll required further purification by gel permeation chromatography and/or SPE (ENVI-Carb). The methodology developed here was fully validated; the LOQs for the 204 pesticides are presented. The LOQ values lie between 0.01 to 0.02 mg/kg. However, in some cases, mainly in baby food, they were as low as 0.003 mg/kg, thereby meeting European Union requirements on maximum residue levels for pesticides, as outlined in European regulation 396/2005 and the Commission Directive 2003/13/EC. The procedure has been accredited for a wide scope of pesticides and matrixes by the Spanish Accreditation Body (ENAC) following ISO/IEC 17025:2005, as outlined in ENAC technical note NT-19.
Dickson, Leslie C; O'Byrne, Collin; Chan, Wayne
2012-01-01
An LC/MS/MS-based multiresidue quantitative method was developed for the macrolides erythromycin A, neospiramycin I, oleandomycin, spiramycin I, tilmicosin, and tylosin A in porcine kidney tissues. The Canadian Food Inspection Agency (CFIA) had as part of its analytical scope an LC/UV method for quantification of residues of two macrolide antibiotics, tilmicosin and tylosin A, in the kidney, liver, and muscle of cattle, swine, and poultry. The method could not reliably detect concentrations below 10 microg/kg. To increase the scope of the CFIA's analytical capabilities, a sensitive multiresidue quantitative method for macrolide residues in food animal tissues was required. Porcine kidney samples were extracted with acetonitrile and alkaline buffer and cleaned-up using silica-based C18 SPE cartridges. Sample extracts were analyzed using LC/MS/MS with positive electrospray ionization. Fitness for purpose was verified in a single-laboratory validation study using a second analyst. The working analytical range was 5 to 50 microg/kg. LOD and LOQ were 0.5 to 0.6 microg/kg and 1.5 to 3.0 microg/kg, respectively. Limits of identification were 0.5 to 2.0 microg/kg. Relative intermediate precisions were 8 to 17%. Average absolute recoveries were 68 to 76%.
Villagrasa, M; Guillamón, M; Navarro, A; Eljarrat, E; Barceló, D
2008-02-01
A new analytical method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soils based on the use of pressurized liquid extraction (PLE) followed by solid-phase extraction (SPE) and then instrumental determination using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) is described. Using this method, the characterization, separation and quantitative detection of a mixture of two benzoxazolinones, benzoxazolin-2-one (BOA) and 6-methoxybenzoxazolin-2-one (MBOA) and their degradation products, 2-aminophenol (APH), N-(2-hydroxyphenyl)malonamic acid (HMPMA), 2-amino-3-H-phenoxazin-3-one (APO), 9-methoxy-2-amino-3-H-phenoxazin-3-one (AMPO), 2-acetylamino-3-H-phenoxazin-3-one (AAPO) and 2-acetylamino-9-methoxy-2-amino-3-H-phenoxazin-3-one (AAMPO) was achieved. The complete LC-ESI-MS-MS precursor-product ion fragmentation pathways for the degradation products of benzoxazolinones are described for the first time. Quantitative analysis was done in the multiple reaction mode using two specific combinations of precursor-product ion transitions for each compound. The optimized method was quality assessed by the measure of parameter as recovery, linearity, sensitivity, repeatability and reproducibility. Recoveries of the analytes ranged from 53 to 123%. The developed method offered improvements to the sensitivity as compared with our previously LC-MS method, with detection limits down to 2.4-21 ng/g of dry weight. This achievement allows us to identify and quantify for the first time degradation products of benzoxazolinones in real agricultural soil samples. Analytes were found in the range of 20.6-149 ng/g dry weight.
Grace, Philip B; Drake, Erica C; Teale, Philip; Houghton, Edward
2008-10-01
Following administration of the anabolic steroid 19-nortestosterone or its esters to the horse, a major urinary metabolite is 19-nortestosterone-17beta-sulphate. The detection of 19-nortestosterone in urine from untreated animals has led to it being considered a naturally occurring steroid in the male horse. Recently, we have demonstrated that the majority of the 19-nortestosterone found in extracts of 'normal' urine from male horses arises as an artefact through decarboxylation of the 19-carboxylic acid of testosterone. The aim of this investigation was to establish if direct analysis of 19-nortestosterone-17beta-sulphate by liquid chromatography/tandem mass spectrometry (LC/MS/MS) had potential for the detection of 19-nortestosterone misuse in the male horse. The high concentrations of sulphate conjugates of the female sex hormones naturally present in male equine urine were overcome by selective hydrolysis of the aryl sulphates using glucuronidase from Helix pomatia; this was shown to have little or no activity for alkyl sulphates such as 19-nortestosterone-17beta-sulphate. The 'free' phenolic steroids were removed by solid-phase extraction (SPE) prior to LC/MS/MS analysis. The method also allowed for the quantification of the sulphate conjugate of boldenone, a further anabolic steroid endogenous in the male equine with potential for abuse in sports. The method was applied to the quantification of these analytes in a population of samples. This paper reports the results of that study along with the development and validation of the LC/MS/MS method. The results indicate that while 19-nortestosterone-17beta-sulphate is present at low levels as an endogenous substance in urine from 'normal' male horses, its use as an effective threshold substance may be viable.
Measurement of bromate in bread by liquid chromatography with post-column flow reactor detection.
Himata, K; Noda, M; Ando, S; Yamada, Y
2000-01-01
This method is suitable for the determination of bromate residues in a variety of baked goods. The peer-verified method trial was performed on white bread, multigrain bread, and coffee cake spiked with known levels of potassium bromate. The analytical portion is extracted with deionized water to remove bromate from the bulk of the baked product. The aqueous extract is carried through a series of steps to remove co-extractives that would interfere with the liquid chromatography (LC) in the determinative step or hasten the deterioration of the LC column. The extract is filtered before passing it through a reversed-phase solid-phase extraction (SPE) column and a cation-exchange column in the silver form to remove lipids and chloride, respectively. Ultrafiltration is then used to remove proteins with molecular weights of >30,000 daltons. Finally, a cation-exchange column in the sodium form is used to remove silver ions from the extract. The determinative step uses LC with a reversed-phase column and an ion-pairing agent in the mobile phase. Detection is based on the post-column reaction of bromate with o-dianisidine to form an oxidation product that is quantitated spectrophotometrically at 450 nm. Overall agreement between the submitting and peer laboratories was quite good. For bromate levels of 10-52 ppb, overall mean recoveries were 76.9 and 78.8% for the submitting and peer laboratories, respectively. The standard deviations were higher for the results of the peer laboratory, probably because of the generally higher level of baseline noise present in the chromatograms. The results demonstrate that the method provides adequate accuracy with low-fat as well as high-fat foods. Bromate at levels as low as 5 ppb (ng/g) can be detected with the method.
Shi, Xiaomei; Jin, Fen; Huang, Yuting; Du, Xinwei; Li, Chunmei; Wang, Miao; Shao, Hua; Jin, Maojun; Wang, Jing
2012-01-11
An effective method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and optimized to obtain a complete separation of five representative plant growth regulators (PGRs) [gibberellic acid, 2,4-dichlorophenoxyacetic acid (2,4-D), thidiazuron, forchlorfenuron, and paclobutrazol] in fruits. Extraction was performed with acetonitrile containing 0.1% (v/v) acetic acid, applying modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) methodology. LC-MS/MS conditions including composition of mobile phases and mass spectrometry (MS) conditions were evaluated to achieve the highest sensitivity in MS detection. All of the data acquisition was employed in the segmented multiple-reaction monitoring mode for the selected negative and positive transition ions. The octadecylsilyl (C18) dispersive solid-phase extraction (SPE) sorbent was found to provide the more satisfied recoveries than primary secondary amine (PSA) and graphitized carbon black (GCB) for five target PGRs. The optimized method allowed for recoveries of 76-112% for the five PGRs from fruit samples with relative standard deviation (RSD) values less than 10%. Limits of quantification (0.5-16.5 μg/kg) were lower than the maximum limit of residues established for PGRs. The results demonstrated that the developed LC-MS/MS and QuEChERS extraction method is highly effective for analyzing trace amounts of target PGRs in fruit samples. Finally, the method was successfully used to detect residual PGRs in Beijing, China, in 2010. The concentrations of 2,4-D (5.1-1503 μg/kg) and paclobutrazol (1-1381 μg/kg) found in orange and peach, respectively, suggesting that the use of these PGRs in these fruits should be regulated in China in the future.
Rugged large volume injection for sensitive capillary LC-MS environmental monitoring
NASA Astrophysics Data System (ADS)
Roberg-Larsen, Hanne; Abele, Silvija; Demir, Deniz; Dzabijeva, Diana; Amundsen, Sunniva F.; Wilson, Steven R.; Bartkevics, Vadims; Lundanes, Elsa
2017-08-01
A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD) in the 0.05 - 12.5 ng/L range. Between-day and within-day repeatability of selected analytes were < 20% RSD.
Barrett, Yu Chen; Akinsanya, Billy; Chang, Shu-Ying; Vesterqvist, Ole
2005-07-25
A sensitive method for quantitation of urinary 6beta-hydroxycortisol (6beta-HC) and cortisol using on-line SPE and LC-MS/MS was developed and validated. Human urine samples were injected directly onto an on-line solid phase extraction apparatus, Prospekt-2, followed by HPLC separation and electrospray triple quadrupole LC-MS/MS detection. The inter-day precision for the 6beta-HC:cortisol ratio was 7-9%. The lower limit of quantitation was 1 and 0.2 ng/mL for 6beta-HC and cortisol, respectively. Using the method we observed a diurnal variation on the 6beta-HC:cortisol ratio in healthy volunteers with the maximal ratio observed in the 2-10 pm urine collection period.
Breithaupt, Dietmar E
2004-06-16
Negative ion liquid chromatography-atmospheric pressure chemical ionization mass spectrometry [negative ion LC-(APCI)MS] was used for the identification of astaxanthin esters in extracts of commercial shrimp (Pandalus borealis) and dried microalga (Haematococcus pluvialis) samples. A cleanup step using a normal phase solid phase extraction (SPE) cartridge was applied prior to analysis. Recovery experiments with astaxanthin oleate as model compound proved the applicability of this step (98.5 +/- 7.6%; n = 4). The assignment of astaxanthin esters in negative ion LC-(APCI)MS was based on the detection of the molecular ion (M*-) and the formation of characteristic fragment ions, resulting from the loss of one or two fatty acids. Quantification of individual astaxanthin esters was performed using an astaxanthin calibration curve, which was found to be linear over the required range (1-51 micromol/L; r2 = 0.9996). Detection limits, based on the intensity of M*-, a signal-to-noise ratio of 3:1, and an injection volume of 20 microL, were estimated to be 0.05 microg/mL (free astaxanthin), 0.28 microg/mL (astaxanthin-C16:0), and 0.78 microg/mL (astaxanthin-C16:0/C16:0), respectively. This LC-(APCI)MS method allows for the first time the characterization of native astaxanthin esters in P. borealis and H. pluvialis without using time-consuming isolation steps with subsequent gas chromatographic analyses of fatty acid methyl esters. The results suggest that the pattern of astaxanthin-bound polyunsaturated fatty acids of P. borealis does not reflect the respective fatty acid pattern found in triacylglycerides. Application of the presented LC-(APCI)MS technique in common astaxanthin ester analysis will forestall erroneous xanthophyll ester assignment in natural sources.
Gu, Binghe; Meldrum, Brian; McCabe, Terry; Phillips, Scott
2012-01-01
A theoretical treatment was developed and validated that relates analyte concentration and mass sensitivities to injection volume, retention factor, particle diameter, column length, column inner diameter and detection wavelength in liquid chromatography, and sample volume and extracted volume in solid-phase extraction (SPE). The principles were applied to improve sensitivity for trace analysis of clopyralid in drinking water. It was demonstrated that a concentration limit of detection of 0.02 ppb (μg/L) for clopyralid could be achieved with the use of simple UV detection and 100 mL of a spiked drinking water sample. This enabled reliable quantitation of clopyralid at the targeted 0.1 ppb level. Using a buffered solution as the elution solvent (potassium acetate buffer, pH 4.5, containing 10% of methanol) in the SPE procedures was found superior to using 100% methanol, as it provided better extraction recovery (70-90%) and precision (5% for a concentration at 0.1 ppb level). In addition, the eluted sample was in a weaker solvent than the mobile phase, permitting the direct injection of the extracted sample, which enabled a faster cycle time of the overall analysis. Excluding the preparation of calibration standards, the analysis of a single sample, including acidification, extraction, elution and LC run, could be completed in 1 h. The method was used successfully for the determination of clopyralid in over 200 clopyralid monoethanolamine-fortified drinking water samples, which were treated with various water treatment resins. Copyright © 2012 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.
Chen, Xiaolong; Li, Zhengxiang; Cao, Zhaoyun; Cao, Xiaolin; Chen, Mingxue
2013-10-01
A method was developed for the simultaneous determination of mepanipyrim, silthiofam, boscalid, fluopicolide, mandipropamid, cyflufenamid in vegetables and fruits by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analytes were extracted from the samples by acetonitrile and purified by Florisil SPE. The six novel amide fungicides were separated on a Poroshell 120 EC-C18 column with the mobile phases of water and acetonitrile, and finally detected by MS/MS with positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, quantified by external standard method. Under the optimal analytical conditions, the correlation coefficients (r) of the six novel amide fungicides were not lower than 0. 999 0 in the concentration range from 0.5 to 100 microg/L. The limits of detection (S/N > or = 3) of the method were 0.15 microg/kg for boscalid, silthiofam, mandipropamid, cyflufenamid, 0.10 microg/kg for mepanipyrim and 0.17 microg/kg for fluopicolide. The recovery tests were performed for the 7 types of vegetables and the 3 types of fruits at the spiked levels of 0.5, 5 and 50 microg/kg, and the recoveries of the six analytes ranged from 65% to 124% with the relative standard deviations (RSDs, n = 5) of 1%-18%. The matrix effects in vegetables and fruits of the six amide fungicides were significantly reduced by the purification of Florisil SPE compared with the modified QuEChERS. The method is easy, fast, sensitive and accurate, and can meet the requirements of the determination of the six amide fungicide residues in vegetables and fruits.
Bayen, Stéphane; Yi, Xinzhu; Segovia, Elvagris; Zhou, Zhi; Kelly, Barry C
2014-04-18
Emerging contaminants such as antibiotics have received recent attention as they have been detected in natural waters and health concerns over potential antibiotic resistance. With the purpose to investigate fast and high-throughput analysis, and eventually the continuous on-line analysis of emerging contaminants, this study presents results on the analysis of seven selected antibiotics (sulfadiazine, sulfamethazine, sulfamerazine, sulfamethoxazole, chloramphenicol, lincomycin, tylosin) in surface freshwater and seawater using direct injection of a small sample volume (20μL) in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Notably, direct injection of seawater in the LC-ESI-MS/MS was made possible on account of the post-column switch on the system, which allows diversion of salt-containing solutions flushed out of the column to the waste. Mean recoveries based on the isotope dilution method average 95±14% and 96±28% amongst the compounds for spiked freshwater and seawater, respectively. Linearity across six spiking levels was assessed and the response was linear (r(2)>0.99) for all compounds. Direct injection concentrations were compared for real samples to those obtained with the conventional SPE-based analysis and both techniques concurs on the presence/absence and levels of the compounds in real samples. These results suggest direct injection is a reliable method to detect antibiotics in both freshwater and seawater. Method detection limits for the direct injection technique (37pg/L to 226ng/L in freshwater, and from 16pg/to 26ng/L in seawater) are sufficient for a number of environmental applications, for example the fast screening of water samples for ecological risk assessments. In the present study of real samples, this new method allowed for example the positive detection of some compounds (e.g. lincomycin) down to the sub ng/L range. The direct injection method appears to be relatively cheaper and faster, requires a smaller sample size, and is more robust to equipment cross-contamination as compared to the conventional SPE-based method. Copyright © 2014 Elsevier B.V. All rights reserved.
Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert
2009-01-01
An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.
Lehmann, Sabrina; Kieliba, Tobias; Beike, Justus; Thevis, Mario; Mercer-Chalmers-Bender, Katja
2017-10-01
A detailed description is given of the development and validation of a fully automated in-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method capable of detecting 90 central-stimulating new psychoactive substances (NPS) and 5 conventional amphetamine-type stimulants (amphetamine, 3,4-methylenedioxy-methamphetamine (MDMA), 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxy-N-ethyl-amphetamine (MDEA), methamphetamine) in serum. The aim was to apply the validated method to forensic samples. The preparation of 150μL of serum was performed by an Instrument Top Sample Preparation (ITSP)-SPE with mixed mode cation exchanger cartridges. The extracts were directly injected into an LC-MS/MS system, using a biphenyl column and gradient elution with 2mM ammonium formate/0.1% formic acid and acetonitrile/0.1% formic acid as mobile phases. The chromatographic run time amounts to 9.3min (including re-equilibration). The total cycle time is 11min, due to the interlacing between sample preparation and analysis. The method was fully validated using 69 NPS and five conventional amphetamine-type stimulants, according to the guidelines of the Society of Toxicological and Forensic Chemistry (GTFCh). The guidelines were fully achieved for 62 analytes (with a limit of detection (LOD) between 0.2 and 4μg/L), whilst full validation was not feasible for the remaining 12 analytes. For the fully validated analytes, the method achieved linearity in the 5μg/L (lower limit of quantification, LLOQ) to 250μg/L range (coefficients of determination>0.99). Recoveries for 69 of these compounds were greater than 50%, with relative standard deviations≤15%. The validated method was then tested for its capability in detecting a further 21 NPS, thus totalling 95 tested substances. An LOD between 0.4 and 1.6μg/L was obtained for these 21 additional qualitatively-measured substances. The method was subsequently successfully applied to 28 specimens from routine forensic case work, of which 7 samples were determined to be positive for NPS consumption. Copyright © 2017 Elsevier B.V. All rights reserved.
Nguyen, Van Long
2018-02-25
There has been increasing interest in the analysis of phospholipids in red blood cells as potential long-term biomarkers of different disease states. Here, we describe a simple method for the analysis of two phospholipids: 1-Palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanol (PE 16:0/18:1) and 1-Palmitoyl-2-linoleoyl-sn-glycero-3-phosphoethanol (PE 16:/0/18:2) in erythrocytes by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Whole blood samples were removed free of plasma and washed in isotonic saline. Red cells were lysed with ultrapure water. Lysate samples were processed using a hybrid solid-phase extraction (SPE) phospholipid cartridge (1 mL, 30 mg). Both PE 16:0/18:1 and PE 16:0/18:2 and their deuterated internal standards were separated on an ACE C4 (150 mm × 2.1 mm, 2.7 μm particle size) by gradient elution at a flow rate of 0.5 mL per minute using mobile phases consisting of 0.01 mol/L ammonium acetate in: water (A), methanol (B), and isopropanol (C). The phospholipid species were quantified by the following transitions: PE 16:0/18:1: 701.5→281.3 and PE 16:0/18:2: 699.5→279.3. Both PE species displayed linearity ranging from 10 to 500 μg/L. The coefficient of variation (CV%) of PE 16:0/18:1 concerning intraday and interday precision was between 1.9%-2.6% and 3.0%-4.3%, respectively. For PE 16:0/18:2, this was between 1.8%-3.4% and 3.7%-4.1%, respectively. Both phospholipid species had accuracy (PE 16:0/18:1: 91%-98% and PE 16:0/18:2: 94%-103%) and extraction recovery (PE 16:0/18:1: 95%-106% and PE 16:0/18:2: 92%-102%) exceeding 90% over the analytical range. The limit of detection was 5 μg/L. Here we propose a simple SPE LC-MS/MS method for analyzing phospholipids in erythrocytes, which can be easily adopted. © 2018 Wiley Periodicals, Inc.
Della Pelle, Flavio; Di Crescenzo, Maria Chiara; Sergi, Manuel; Montesano, Camilla; Di Ottavio, Francesca; Scarpone, Rossana; Scortichini, Giampiero; Compagnone, Dario
2016-01-01
A rapid, selective and effective method of extraction, clean-up and concentration of organophosphorous pesticides from wheat followed by electrospray (ESI) LC-MS/MS analysis was developed. The μ-SPE (micro-solid-phase extraction) procedure resulted in good analytical performance and reduced at the same time matrix effects, analysis time and solvent consumption. Limits of detection (LODs) and quantification (LOQs) were in the range of 0.3-10 and 1-30 μg kg(-1), respectively, with good reproducibility (RSD ≤ 13.8) and recoveries between 75% and 109%. Coefficients of determination (r(2)) were greater than 0.996 for the studied pesticides. Despite the reduced sorbent bed mass of μ-SPE tips (4.2 mg), the analytical data showed that no saturation phenomena occurs in the tested range of concentration both for single compounds and mixtures. Several real samples were analysed and the concentrations of the selected pesticides were found to be below the respective maximum residue limit (MRLs).
Möller, Kristina; Crescenzi, Carlo; Nilsson, Ulrika
2004-01-01
Diphenyl phosphate is a hydrolysis product and possible metabolite of the flame retardant and plasticiser additive triphenyl phosphate. A molecularly imprinted polymer solid-phase extraction (MISPE) method for extracting diphenyl phosphate from aqueous solutions has been developed and compared with SPE using a commercially available mixed-mode anion exchanger. The imprinted polymer was prepared using 2-vinylpyridine (2-Vpy) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and a structural analogue of the analyte as the template molecule. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with both aqueous standards and spiked urine samples, by comparing recovery and breakthrough data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from aqueous solutions resulted in more than 80% recovery. Adsorption by the molecularly imprinted polymer (MIP) was non-selective, but selectivity was achieved by selective desorption in the wash steps. Diphenyl phosphate could also be selectively extracted from urine samples, although the urine matrix reduced the capacity of the MISPE cartridges. Recoveries from urine extraction were higher than 70%. It was important to control pH during sample loading. The MISPE method was found to yield a less complex LC-ESI-MS chromatogram of the urine extracts compared with the mixed-mode anion-exchanger method. An LC-ESI-MS method using a Hypercarb LC column with a graphitised carbon stationary phase was also evaluated for organophosphate diesters. LC-ESI-MS using negative-ion detection in selected ion monitoring (SIM) mode was shown to be linear for diphenyl phosphate in the range 0.08-20 ng microL(-1).
Sturm, Sonja; Seger, Christoph; Godejohann, Markus; Spraul, Manfred; Stuppner, Hermann
2007-09-07
Identification of putative biomarker molecules within the genus Corydalis (Papaveraceae) was pursued by combining conventional off-line sample enrichment with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance (HPLC-SPE-NMR) based structure elucidation. Off-line reversed phase solid phase extraction (SPE) was used to enrich the desired analytes from a methanolic extract (93 mg dry weight) of a miniscule single tuber (233 mg dry weight) of C. solida. An aliquot of the SPE fraction (2.1 mg) was subjected to separation in the HPLC-SPE-NMR hyphenation. Chromatographic peaks bearing the metabolites under investigation were trapped in the SPE device in a single experiment and transferred to a 600 MHz NMR spectrometer equipped with a 30 microl cryofit insert fed into a 3 mm cryoprobe. Recorded homo- and heteronuclear 1D and 2D NMR data allowed the identification of the three analytes under investigation as protopine, allocryptopine, and N-methyl-laudanidinium acetate. The latter is a rare alkaloid, which has been isolated only once before.
Microfluidic LC Device with Orthogonal Sample Extraction for On-Chip MALDI-MS Detection
Lazar, Iulia M.; Kabulski, Jarod L.
2013-01-01
A microfluidic device that enables on-chip matrix assisted laser desorption ionization-mass spectrometry (MALDI-MS) detection for liquid chromatography (LC) separations is described. The device comprises an array of functional elements to carry out LC separations, integrates a novel microchip-MS interface to facilitate the orthogonal transposition of the microfluidic LC channel into an array of reservoirs, and enables sensitive MALDI-MS detection directly from the chip. Essentially, the device provides a snapshot MALDI-MS map of the content of the separation channel present on the chip. The detection of proteins with biomarker potential from MCF10A breast epithelial cell extracts, and detection limits in the low fmol range, are demonstrated. In addition, the design of the novel LC-MALDI-MS chip entices the promotion of a new concept for performing sample separations within the limited time-frame that accompanies the dead-volume of a separation channel. PMID:23592150
Lindström, Mikael; Tohmola, Niina; Renkonen, Risto; Hämäläinen, Esa; Schalin-Jäntti, Camilla; Itkonen, Outi
2018-07-01
Serotonin (5-hydroxytyramine) is a mediator of gastrointestinal smooth muscle contraction, and is secreted by neuroendocrine neoplasms (NENs). We developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for serum serotonin to be used in NEN diagnostics and follow-up. We used serum samples from healthy volunteers (n = 31) and patients suspected or monitored for NEN (n = 98). Serotonin-D 4 internal standard was added to samples before solid phase extraction (SPE) and quantification by LC-MS/MS. The effects of sample handling and preparation on serotonin stability were studied. Finally, we established a provisional reference range for serum serotonin and compared our assay with serum 5-hydroxyindoleacetic acid (5-HIAA) for detection of NENs. Our assay is sensitive and has a wide linear range (10-10,000 nmol/l). Serum serotonin is stable for 7 days at room temperature and for 3 months at -20 °C. Sampling temperature is not critical. Normal range for serum serotonin was 270-1490 nmol/l. We found that serum serotonin and 5-HIAA performed equally well as diagnostic tests for NENs. Our LC-MS/MS assay for serum serotonin is well suited for clinical research and patient diagnostics. Our results confirm that it can complement 5-HIAA in diagnosis of NENs. Copyright © 2018 Elsevier B.V. All rights reserved.
First LC/MS determination of cyanazine amide, cyanazine acid, and cyanazine in groundwater samples
Ferrer, Imma; Thurman, E.M.; Barceló, Damià
2000-01-01
Cyanazine and two of its major metabolites, cyanazine amide and cyanazine acid, were measured at trace levels in groundwater using liquid chromatography/atmospheric pressure chemical ionization/mass spectrometry (LC/APCI/MS). Solid-phase extraction was carried out by passing 20 mL of groundwater sample through a cartridge containing a polymeric phase (PLRP-s), with recoveries ranging from 99 to 108% (n = 5). Using LC/MS detection in positive ion mode, useful structural information was obtained by increasing the fragmentor voltage, thus permitting the unequivocal identification of these compounds in groundwater samples with low sample volumes. The fragmentation of the amide, carboxylic acid, and cyano group was observed for both metabolites and cyanazine, respectively, leading to a diagnostic ion at m/z 214. Method detection limits were in the range of 0.002−0.005 μg/L for the three compounds. Finally, the newly developed method was evaluated for the analysis of groundwater samples from New York containing the compounds under study and presents evidence that the metabolites, cyanazine acid, and cyanazine amide may leach to groundwater and serve as sources for deisopropylatrazine. The combination of on-line SPE and LC/APCI/MS represents an important advance in environmental analysis of herbicide metabolites in groundwater since it demonstrates that trace amounts of polar metabolites may be determined rapidly. Furthermore, the presence of both cyanazine amide and cyanazine acid indicate that another degradation product, deisopropylatrazine, may be occurring at depth because of the subsequent degradation of cyanazine.
Adelhelm, Christoph; Niessner, Reinhard; Pöschl, Ulrich
2008-01-01
The analysis of organic compounds in combustion exhaust particles and the chemical transformation of soot by nitrogen oxides are key aspects of assessment and mitigation of the climate and health effects of aerosol emissions from fossil fuel combustion and biomass burning. In this study we present experimental and analytical techniques for efficient investigation of oxygenated and nitrated derivatives of large polycyclic aromatic hydrocarbons (PAHs), which can be regarded as well-defined soot model substances. For coronene and hexabenzocoronene exposed to nitrogen dioxide under simulated diesel exhaust conditions, several reaction products with high molecular mass could be characterized by liquid chromatography-atmospheric pressure chemical (and photo) ionization-mass spectrometry (LC-APCI-MS and LC-APPI-MS). The main products of coronene contained odd numbers of nitrogen atoms (m/z 282, 256, 338), whereas one of the main products of hexabenzocoronene exhibited an even number of nitrogen atoms (m/z 391). Various reaction products containing carbonyl and nitro groups could be tentatively identified by combining chromatographic and mass spectrometric information, and changes of their relative abundance were observed to depend on the reaction conditions. This analytical strategy should highlight a relatively young technique for the characterization of various soot-contained, semi-volatile, and semi-polar reaction products of large PAHs. Figure LC-APCI-MS analysis of nitrated coronene (and HBC): Total-Ion-Chromatogram (TIC), Extracted Ion Chromatograms (EICs) and corresponding mass spectrum (top). PMID:18560812
Amarasinghe, Kande; Chu, Pak-Sin; Evans, Eric; Reimschuessel, Renate; Hasbrouck, Nicholas; Jayasuriya, Hiranthi
2012-05-23
This paper describes the development of a fast method to screen and confirm methyltestosterone 17-O-glucuronide (MT-glu) in tilapia bile. The method consists of solid-phase extraction (SPE) followed by high-performance liquid chromatography-mass spectrometry. The system used was an Agilent 6530 Q-TOF with an Agilent Jet stream electrospray ionization interface. The glucuronide detected in the bile was characterized as MT-glu by comparison with a chemically synthesized standard. MT-glu was detected in bile for up to 7 days after dosing. Semiquantification was done with matrix-matched calibration curves, because MT-glu showed signal suppression due to matrix effects. This method provides a suitable tool to monitor the illegal use of methyltestosterone in tilapia culture.
Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez
2011-07-15
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Smital, Tvrtko; Terzic, Senka; Zaja, Roko; Senta, Ivan; Pivcevic, Branka; Popovic, Marta; Mikac, Iva; Tollefsen, Knut Erik; Thomas, Kevin V; Ahel, Marijan
2011-05-01
The hazardous chemical contamination of untreated wastewater and secondary effluent from the wastewater treatment plant (WWTP) of the city of Zagreb, Croatia was comprehensively characterized using large-volume solid-phase extraction (SPE) and silica gel fractionation, followed by a detailed analysis of the resulting extracts by a combination of chemical and bioassay methods. Over 100 individual contaminants or closely related-contaminant groups were identified by high-resolution gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF). Ecotoxicity profiling of the investigated samples, including cytotoxicity, chronic toxicity and EROD activity; inhibition of the multixenobiotic resistance (MXR), genotoxicity and estrogenic potential, revealed the most significant contribution of toxic compounds to be present in polar fractions. Wastewater treatment using conventional activated sludge process reduced the initial toxicity of raw wastewater to various extents, ranging from 28% for algal toxicity to 73.2% for an estrogenic activity. The most efficient toxicity removal was observed for the polar compounds. Copyright © 2010 Elsevier Inc. All rights reserved.
Xia, Xi; Li, Xiaowei; Ding, Shuangyang; Zhang, Suxia; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong
2009-03-20
This work reports a rapid, reliable and sensitive multi-residue method for the simultaneous determination of six resorcylic acid lactones in bovine milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The resorcylic acid lactones were extracted, purified, and concentrated from milk samples in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric mixed-mode anion-exchange sorbent. The analysis was performed on a Waters Acquity BEH C(18) column utilizing a gradient elution profile. Each LC run was completed in 3.5 min. The analytes were detected by multiple reaction monitoring (MRM) using electrospray ionization (ESI) negative mode. Mean recoveries from fortified samples ranged from 92.6% to 112.5%, with relative standard deviations lower than 11.4%. Using 5 mL bovine milk, the limits of detection and quantification for resorcylic acid lactones were in the ranges of 0.01-0.05 and 0.05-0.2 microg/L, respectively. The application of this newly developed method was demonstrated by analyzing bovine milk samples from markets.
Asimakopoulos, Alexandros G; Thomaidis, Nikolaos S
2015-04-01
A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and optimized for the simultaneous determination of bisphenol A, 4-t-octylphenol and 4-nonylphenol in human blood serum. For the first time, the electrospray ionization (ESI) parameters of probe position, voltage potential, sheath gas flow rate, auxiliary gas flow rate, and ion transfer tube temperature were thoroughly studied and optimized for each phenol by a univariate approach. As a consequence, low instrumental limits of detection were reported, demonstrating at 0.2 ng/mL (in solvent matrix) excellent injection repeatability (RSD<14.5%) and a confirmation peak for all target phenols. Extraction and purification of serum was performed by the novel Hybrid Solid Phase Extraction-Precipitation Technology technique (Hybrid SPE-PPT). The limits of detection in human blood serum were 0.80, 1.3 and 1.4 ng/mL for BPA, 4-t-OP and 4-NP, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
MacMahon, Shaun; Begley, Timothy H; Diachenko, Gregory W
2013-05-22
A method was developed and validated for the detection of fatty acid diesters of 2-monochloropropanediol (2-MCPD) and 3-monochloropropanediol (3-MCPD) in edible oils. These analytes are potentially carcinogenic chemical contaminants formed during edible oil processing. After separation from oil matrices using a two-step solid-phase extraction (SPE) procedure, the target compounds are quantitated using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). The first chromatographic conditions have been developed that separate intact diesters of 2-MCPD and 3-MCPD, allowing for their individual quantitation. The method has been validated for 28 3-MCPD diesters of lauric, myristic, palmitic, linolenic, linoleic, oleic, and stearic acids in coconut, olive, and palm oils, as well as 3 2-MCPD diesters, using an external calibration curve. The range of average recoveries and relative standard deviations (RSDs) across the three oil matrices at three spiking concentrations are 88-118% (2-16% RSD) with maximum limits of quantitation of 30 ng/g (ppb).
Ben, Weiwei; Qiang, Zhimin; Adams, Craig; Zhang, Heqing; Chen, Liping
2008-08-22
Little is known about the contamination level of antibiotics in swine wastewater in China. The highly complex matrix of swine wastewater, which generally has a chemical oxygen demand (COD) concentration as high as 15,000 mg/L, makes it difficult to detect antibiotics at trace levels. In this work, a highly selective and sensitive analytical method was developed for simultaneous determination of three classes of commonly used veterinary antibiotics including five sulfonamides, three tetracyclines and one macrolide in swine wastewater using solid-phase extraction (SPE) and liquid chromatography-mass spectrometry (LC-MS). The method detection limits (MDL) in the swine wastewater were determined to be between 5 and 91 ng/L, depending on specific antibiotics. Except sulfamethizole, all the other eight antibiotics were detected in the swine wastewaters collected from three concentrated swine feeding plants located in the Beijing (China) area, showing a concentration range of 0.62-32.67 microg/L. These results reveal the representative concentration levels of selected antibiotics in the swine wastewaters of Beijing area.
Kenny, O; Smyth, T J; Hewage, C M; Brunton, N P; McLoughlin, P
2014-02-01
The combination of hyphenated techniques, LC-SPE-NMR and LC-MS, to isolate and identify minor isomeric compounds from an ethyl acetate fraction of Taraxacum officinale root was employed in this study. Two distinct fractions of 4-hydroxyphenylacetic acid derivatives of inositol were isolated and characterised by spectroscopic methods. The (1)H NMR spectra and MS data revealed two groups of compounds, one of which were derivatives of the di-4-hydroxyphenylacetic acid derivative of the inositol compound tetrahydroxy-5-[2-(4-hydroxyphenyl)acetyl] oxycyclohexyl-2-(4-hydroxyphenyl) acetate, while the other group consisted of similar tri-substituted inositol derivatives. For both fractions the derivatives of inositols vary in the number of 4-hydroxyphenylacetic acid groups present and their position and geometry on the inositol ring. In total, three di-substituted and three tri-substituted 4-hydroxyphenylacetic acid inositol derivates were identified for the first time along with a further two previously reported di-substituted inositol derivatives. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chen, Dongmei; Yu, Jie; Tao, Yanfei; Pan, Yuanhu; Xie, Shuyu; Huang, Lingli; Peng, Dapeng; Wang, Xu; Wang, Yulian; Liu, Zhenli; Yuan, Zonghui
2016-04-01
A method for the analysis of 120 drugs in animal derived food was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). These analytes belong to 12 families of veterinary anti-microbial agents (quinolones, macrolides, β-lactams, nitroimidazoles, sulfonamides, lincomycines, chloramphenicols, quinoxalines, tetracyclines, polypeptides, and antibacterial synergists) as well as other compounds not assigned to a particular drug family. The animal derived food samples include muscle and liver of swine, bovine, sheep, and chicken, as well as hen eggs and dairy milk. The sample preparation included ultrasound-assisted extraction (UAE) with acetonitrile-water and a final clean-up with auto solid-phase extraction (SPE) on HLB cartridges. The detection and quantification of 120 anti-microbial agents was performed using LC-MS/MS in positive and negative ion mode. The chromatographic separation was performed on a C18 column using acetonitrile and 0.1% formic acid as the mobile phase. The limit of detection (LOD) and limit of quantification (LOQ) of all drugs in food-producing animals were 0.5-3.0μg/kg and 1.5-10.0μg/kg, respectively. The developed method was successfully utilized to monitor real samples, which demonstrated that it is a simple, fast, and robust method, and could be used as a regulatory to screen for the presence of residues from veterinary anti-microbial drugs in animal-derived foods. Copyright © 2016 Elsevier B.V. All rights reserved.
Al-Sammak, Maitham Ahmed; Hoagland, Kyle D; Cassada, David; Snow, Daniel D
2014-01-28
Several groups of microorganisms are capable of producing toxins in aquatic environments. Cyanobacteria are prevalent blue green algae in freshwater systems, and many species produce cyanotoxins which include a variety of chemical irritants, hepatotoxins and neurotoxins. Production and occurrence of potent neurotoxic cyanotoxins β-N-methylamino-L-alanine (BMAA), 2,4-diaminobutyric acid dihydrochloride (DABA), and anatoxin-a are especially critical with environmental implications to public and animal health. Biomagnification, though not well understood in aquatic systems, is potentially relevant to both human and animal health effects. Because little is known regarding their presence in fresh water, we investigated the occurrence and potential for bioaccumulation of cyanotoxins in several Nebraska reservoirs. Collection and analysis of 387 environmental and biological samples (water, fish, and aquatic plant) provided a snapshot of their occurrence. A sensitive detection method was developed using solid phase extraction (SPE) in combination with high pressure liquid chromatography-fluorescence detection (HPLC/FD) with confirmation by liquid chromatography-tandem mass spectrometry (LC/MS/MS). HPLC/FD detection limits ranged from 5 to 7 µg/L and LC/MS/MS detection limits were <0.5 µg/L, while detection limits for biological samples were in the range of 0.8-3.2 ng/g depending on the matrix. Based on these methods, measurable levels of these neurotoxic compounds were detected in approximately 25% of the samples, with detections of BMAA in about 18.1%, DABA in 17.1%, and anatoxin-a in 11.9%.
Al-Sammak, Maitham Ahmed; Hoagland, Kyle D.; Cassada, David; Snow, Daniel D.
2014-01-01
Several groups of microorganisms are capable of producing toxins in aquatic environments. Cyanobacteria are prevalent blue green algae in freshwater systems, and many species produce cyanotoxins which include a variety of chemical irritants, hepatotoxins and neurotoxins. Production and occurrence of potent neurotoxic cyanotoxins β-N-methylamino-l-alanine (BMAA), 2,4-diaminobutyric acid dihydrochloride (DABA), and anatoxin-a are especially critical with environmental implications to public and animal health. Biomagnification, though not well understood in aquatic systems, is potentially relevant to both human and animal health effects. Because little is known regarding their presence in fresh water, we investigated the occurrence and potential for bioaccumulation of cyanotoxins in several Nebraska reservoirs. Collection and analysis of 387 environmental and biological samples (water, fish, and aquatic plant) provided a snapshot of their occurrence. A sensitive detection method was developed using solid phase extraction (SPE) in combination with high pressure liquid chromatography-fluorescence detection (HPLC/FD) with confirmation by liquid chromatography-tandem mass spectrometry (LC/MS/MS). HPLC/FD detection limits ranged from 5 to 7 µg/L and LC/MS/MS detection limits were <0.5 µg/L, while detection limits for biological samples were in the range of 0.8–3.2 ng/g depending on the matrix. Based on these methods, measurable levels of these neurotoxic compounds were detected in approximately 25% of the samples, with detections of BMAA in about 18.1%, DABA in 17.1%, and anatoxin-a in 11.9%. PMID:24476710
Kabir, Md Humayun; Abd El-Aty, A M; Rahman, Md Musfiqur; Chung, Hyung Suk; Lee, Han Sol; Park, Sun-Hyang; Hacımüftüoğlu, Fazil; Chang, Byung-Joon; Shin, Ho-Chul; Shim, Jae-Han
2017-06-01
Amisulbrom formulated as suspension concentrate was applied at the rate recommended for Korean melon to determine the dissipation pattern (at two different sites), the pre-harvest residue limit (PHRL), and risk assessments. Samples collected over 10 days were extracted using liquid-liquid extraction (LLE) and cleaned up with solid-phase extraction (SPE) Florisil cartridge. Residual concentrations were determined using liquid chromatography-ultraviolet detector (LC-UVD) and confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The standard showed good instrument response linearity with a correlation coefficient (R 2 ) = 0.9999, and the recovery ranged from 87.5 to 93.7%. The dissipation half-life calculated from two different sites were found to be 7.0 and 8.8 days for sites 1 and 2, respectively. A PHRL graph constructed from the data indicated that if the residue levels were less than 0.55-0.59 mg/kg 3 days before harvest or less than 0.61-0.74 mg/kg 7 days before harvest, then they would be lower than the maximum residue limits (MRLs) at harvest. Risk assessments showed that the risk quotient (RQ) was 4.39-3.47% at 0 day, declined to 1.53-1.63% at 10 days. Therefore, the current data indicate that the amisulbrom can be applied safely to Korean melon; hence, it is unlikely to induce adverse health effects in consumers.
Tian, He; Wang, Jiaqi; Zhang, Yangdong; Li, Songli; Jiang, Jindou; Tao, Dali; Zheng, Nan
2016-10-15
A simple and fast multiresidue extraction and purification method was developed for the determination of 61 veterinary drugs, belonging to seven classes, in milk and milk powder. The extraction depends on the acetonitrile solvent, followed by a single step to remove lipids with fatty acid chains using a new reversed phase SPE without traditional pre-equilibration and washing steps before eluting SPE. The purifying lipid effect of the present preparation method was evaluated by comparing the response changes of ion peak areas of the milk endogenous metabolites before and after SPE treatment using ultra-fast LC coupled to tandem quadrupole and TOF MS. Subsequently, UPLC coupled to tandem quadrupole MS was performed for the quantitative analysis of milk and milk powder samples spiked with 61 veterinary drugs, including β-lactam, macrolide, amide alcohol, forest amine, sulfanilamide, tetracyclines, and quinolones antibiotics. This method is very simple, fast, sensitive, and selective, and allows the good recoveries of all compounds, with a recovery range of 61.5-118.6%, and coefficients of variation of less than 11.6%. The 61 compounds behave in the dynamic range 0.01-200μgkg(-1), with correlation coefficient >0.99. The limits of quantification for the analytes are in the range 0.01-5.18μgkg(-1). Finally, this method has been successfully applied to the screening of veterinary drugs in 50 commercial bovine milk and milk powder samples, and ceftiofur and ciprofloxacin were detected in some brand samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Vidal, Lorena; Robin, Orlane; Parshintsev, Jevgeni; Mikkola, Jyri-Pekka; Riekkola, Marja-Liisa
2013-04-12
Quaternary ammonium-functionalized silica materials were synthesized and applied for solid-phase extraction (SPE) of aromatic amines, which are classified as priority pollutants by US Environmental Protection Agency. Hexamethylenetetramine used for silica surface modification for the first time was employed as SPE sorbent under normal phase conditions. Hexaminium-functionalized silica demonstrated excellent extraction efficiencies for o-toluidine, 4-ethylaniline and quinoline (recoveries 101-107%), while for N,N-dimethylaniline and N-isopropylaniline recoveries were from low to moderate (14-46%). In addition, the suitability of 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica as SPE sorbent was tested under normal phase conditions. The recoveries achieved for the five aromatic amines ranged from 89 to 99%. The stability of the sorbent was evaluated during and after 150 extractions. Coefficients of variation between 4.5 and 10.2% proved a high stability of the synthesized sorbent. Elution was carried out using acetonitrile in the case of hexaminium-functionalized silica and water for 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent. After the extraction the analytes were separated and detected by liquid chromatography ultraviolet detection (LC-UV). The retention mechanism of the materials was primarily based on polar hydrogen bonding and π-π interactions. Comparison made with activated silica proved the quaternary ammonium-functionalized materials to offer different selectivity and better extraction efficiencies for aromatic amines. Finally, 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent was successfully tested for the extraction of wastewater and soil samples. Copyright © 2013 Elsevier B.V. All rights reserved.
A long life 4 V class lithium-ion polymer battery with liquid-free polymer electrolyte
NASA Astrophysics Data System (ADS)
Kobayashi, Yo; Shono, Kumi; Kobayashi, Takeshi; Ohno, Yasutaka; Tabuchi, Masato; Oka, Yoshihiro; Nakamura, Tatsuya; Miyashiro, Hajime
2017-02-01
Ether-based solid polymer electrolyte (SPE) is one of the most well-known lithium ion conductors. Unlike the other inorganic electrolytes, SPE exhibits advantages of flexibility and large-area production, enabling low cost production of large size batteries. However, because the ether group is oxidized at 4 V versus Li/Li+ cathode, and due to its high irreversibility with the carbon anode, ether-based SPE was believed to be inapplicable to 4 V class lithium-ion batteries with carbon anode. Here we report a remarkably stable SPE in combination with a 4 V class cathode and carbon anode achieved by the proper design at the interface. The introduced boron-based lithium salt prohibits further oxidation of SPE at the cathode interface. The surface modification of graphite by the annealing of polyvinyl chloride mostly prohibits the continuous consumption of lithium at the graphite anode. Using above interface design, we achieved 60% capacity retention after 5400 cycles. The proposed battery provides a possible approach for realizing flammable electrolyte-free lithium-ion batteries, which achieve innovative safety improvements of large format battery systems for stationary use.
Serrano, Ana Belén; Capriotti, Anna Laura; Cavaliere, Chiara; Piovesana, Susy; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo
2015-01-01
A novel method for the simultaneous determination of enniatins A, A1, B and B1 and beauvericin, both in human urine and plasma samples, was developed and validated. The method consisted of a simple and easy pretreatment, specific for each matrix, followed by solid phase extraction (SPE) and detection by high performance liquid chromatography-tandem mass spectrometry with an electrospray ion source. The optimized SPE method was performed on graphitized carbon black cartridges after suitable dilution of the extracts, which allowed high mycotoxin absolute recoveries (76%–103%) and the removal of the major interferences from the matrix. The method was extensively evaluated for plasma and urine samples separately, providing satisfactory results in terms of linearity (R2 of 0.991–0.999), process efficiency (>81%), trueness (recoveries between 85% and 120%), intra-day precision (relative standard deviation, RSD < 18%), inter-day precision (RSD < 21%) and method quantification limits (ranging between 20 ng·L−1 and 40 ng·L−1 in plasma and between 5 ng·L−1 and 20 ng·L−1 in urine). Finally, the highly sensitive validated method was applied to some urine and plasma samples from different donors. PMID:26371043
Luo, Xiao-Fei; Yang, Yuan; Sun, Cheng-Jun
2012-01-01
To develop a method for the simultaneous determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection. Organophosphorus pesticides in food were extracted ultrasonically with water. Then the extract was cleaned-up with SPE disk and eluted with ethyl acetate. Finally the eluent was condensed to 1mL under N2 at 55 degrees C. Gas chromatography was applied for quantitative detection of the organophosphorus pesticides in the sample. The linear range of the method for all the pesticides were in the range of 0.01-0.5 mg/kg with correlation coefficients of 0.992-1.000. The detection limits of the method were in the range of 0.0005-0.01 mg/kg. The recoveries for most pesticides were 60%-120% with relative standard deviations of less than 15%. The method is simple, sensitive, environmentally friendly and suitable for the determination of organophosphorous pesticides in food.
Glycidyl fatty acid esters in food by LC-MS/MS: method development.
Becalski, A; Feng, S Y; Lau, B P-Y; Zhao, T
2012-07-01
An improved method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of glycidyl fatty acid esters in oils was developed. The method incorporates stable isotope dilution analysis (SIDA) for quantifying the five target analytes: glycidyl esters of palmitic (C16:0), stearic (C18:0), oleic (C18:1), linoleic (C18:2) and linolenic acid (C18:3). For the analysis, 10 mg sample of edible oil or fat is dissolved in acetone, spiked with deuterium labelled analogs of glycidyl esters and purified by a two-step chromatography on C18 and normal silica solid phase extraction (SPE) cartridges using methanol and 5% ethyl acetate in hexane, respectively. If the concentration of analytes is expected to be below 0.5 mg/kg, 0.5 g sample of oil is pre-concentrated first using a silica column. The dried final extract is re-dissolved in 250 μL of a mixture of methanol/isopropanol (1:1, v/v), 15 μL is injected on the analytical C18 LC column and analytes are eluted with 100% methanol. Detection of target glycidyl fatty acid esters is accomplished by LC-MS/MS using positive ion atmospheric pressure chemical ionization operating in Multiple Reaction Monitoring mode monitoring 2 ion transitions for each analyte. The method was tested on replicates of a virgin olive oil which was free of glycidyl esters. The method detection limit was calculated to be in the range of 70-150 μg/kg for each analyte using 10 mg sample and 1-3 μg/kg using 0.5 g sample of oil. Average recoveries of 5 glycidyl esters spiked at 10, 1 and 0.1 mg/kg were in the range 84% to 108%. The major advantage of our method is use of SIDA for all analytes using commercially available internal standards and detection limits that are lower by a factor of 5-10 from published methods when 0.5 g sample of oil is used. Additionally, MS/MS mass chromatograms offer greater specificity than liquid chromatography-mass spectrometry operated in selected ion monitoring mode. The method will be applied to the survey of glycidyl fatty acid esters in food products on the Canadian market.
Evaluation of analytical techniques to determine AQUI-S® 20E (eugenol) concentrations in water
Meinertz, Jeffery R.; Hess, Karina R.
2014-01-01
There is a critical need in U.S. public aquaculture and fishery management programs for an immediate-release sedative, i.e. a compound that can be safely and effectively used to sedate fish and subsequently, allow for their immediate release. AQUI-S® 20E (10% active ingredient, eugenol; any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government) is being pursued for U.S. approval as an immediate-release sedative. As part of the approval process, data describing animal safety and efficacy are needed. Essential to conducting studies that generate those data, is a method to accurately and precisely determine AQUI-S® 20E concentrations in exposure baths. Spectrophotometric and solid phase extraction (SPE)–high pressure liquid chromatography (LC) methods were developed and evaluated as methods to determine AQUI-S® 20E (eugenol) concentrations in water, methods that could be applied to any situation where eugenol was being evaluated as a fish sedative. The spectrophotometric method was accurate and precise (accuracy, > 87%; precision, 86%; precision < 8.9 %CV) when determining eugenol concentrations in solutions of 50 to 1000 mg/L AQUI-S® 20E made with LC grade water and water with varying pH and hardness. The SPE–LC method was influenced to a lesser degree by the presence of fish feed indicating greater specificity for eugenol.
Analysis of 70 Environmental Protection Agency priority pharmaceuticals in water by EPA Method 1694.
Ferrer, Imma; Zweigenbaum, Jerry A; Thurman, E Michael
2010-09-03
The U.S. Environmental Protection Agency (EPA) Method 1694 for the determination of pharmaceuticals in water recently brought a new challenge for treatment utilities, where pharmaceuticals have been reported in the drinking water of 41-million Americans. This proposed methodology, designed to address this important issue, consists of solid-phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC/MS-MS) using triple quadrupole. Under the guidelines of Method 1694, a multi-residue method was developed, validated, and applied to wastewater, surface water and drinking water samples for the analysis of 70 pharmaceuticals. Four distinct chromatographic gradients and LC conditions were used according to the polarity and extraction of the different pharmaceuticals. Positive and negative ion electrospray were used with two MRM transitions (a quantifier and a qualifier ion for each compound), which adds extra confirmation not included in the original Method 1694. Finally, we verify, for the first time, EPA Method 1694 on water samples collected in several locations in Colorado, where positive identifications for several pharmaceuticals were found. This study is a valuable indicator of the potential of LC/MS-MS for routine quantitative multi-residue analysis of pharmaceuticals in drinking water and wastewater samples and will make monitoring studies much easier to develop for water utilities across the US, who are currently seeking guidance on analytical methods for pharmaceuticals in their water supplies. 2010 Elsevier B.V. All rights reserved.
An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS.
Young, J Bryce; Li, Liang
2006-03-01
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.
Li, Wei; Herrman, Timothy J; Dai, Susie Y
2010-01-01
A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.
Boles, Tammy H; Wells, Martha J M
2016-12-01
Amphetamine and methamphetamine are emerging contaminants-those for which no regulations currently require monitoring or public reporting of their presence in our water supply. In this research, a protocol for weak cation-exchange (WCX) SPE coupled with LC-MS/MS was developed for determination of emerging contaminants amphetamine and methamphetamine in a complex wastewater matrix. Gradient LC parameters were adjusted to yield baseline separation of methamphetamine from other contaminants. Methamphetamine-D5 was used as the internal standard (IS) to compensate for sample loss during SPE and for signal loss during MS (matrix effects). Recoveries were 102.1 ± 7.9% and 99.4 ± 4.0% for amphetamine and methamphetamine, respectively, using WCX sorbent. Notably, methamphetamine was determined to be present in wastewater influent at each sampling date tested. Amphetamine was present in wastewater influent on two of four sampling dates. Amphetamine concentrations ranged from undetectable to 86.4 ng/L in influent, but it was undetectable in wastewater effluent. Methamphetamine was detected in influent at concentrations ranging from 27.0-60.3 ng/L. Methamphetamine concentration was reduced but incompletely removed at this facility. Although absent in one post-UV effluent sample, concentrations of methamphetamine ranged from 10.8-14.8 ng/L. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Evaluation of analytical techniques to determine AQUI-S(R) 20E (eugenol) concentrations in water
Meinertz, Jeffery R.; Hess, Karina R.
2013-01-01
There is a critical need in U.S. public aquaculture and fishery management programs for an immediate-release sedative, i.e. a compound that can be safely and effectively used to sedate fish and subsequently, allow for their immediate release. AQUI-S® 20E (10% active ingredient, eugenol; any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. Government) is being pursued for U.S. approval as an immediate-release sedative. As part of the approval process, data describing animal safety and efficacy are needed. Essential to conducting studies that generate those data, is a method to accurately and precisely determine AQUI-S® 20E concentrations in exposure baths. Spectrophotometric and solid phase extraction (SPE)–high pressure liquid chromatography (LC) methods were developed and evaluated as methods to determine AQUI-S® 20E (eugenol) concentrations in water, methods that could be applied to any situation where eugenol was being evaluated as a fish sedative. The spectrophotometric method was accurate and precise (accuracy, > 87%; precision, < 0.70 %CV) when determining eugenol concentrations in solutions of 50 to 1000 mg/L AQUI-S® 20E made with LC grade water and water with varying pH and hardness. The spectrophotometric method's accuracy was negatively affected when analyzing water containing fish feed. The SPE–LC method was also accurate and precise (accuracy > 86%; precision < 8.9 %CV) when determining eugenol concentrations in solutions of 50 to 1000 mg/L AQUI-S® 20E made with LC grade water and water with varying pH and hardness. The SPE–LC method was influenced to a lesser degree by the presence of fish feed indicating greater specificity for eugenol.
Bacaloni, Alessandro; Callipo, Luciano; Corradini, Eleonora; Giansanti, Piero; Gubbiotti, Riccardo; Samperi, Roberto; Laganà, Aldo
2009-09-04
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M-H](-) for TBBP-A, [M-Br+O](-), and [M-2Br+O](-) for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025-10 ng injected for all compounds. Coefficients of determination R(2) ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid-liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81-88%, 78-92%, and 43-99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected, and method quantification limits were 0.2-3.3 ng L(-1) but BDE47 (20.3 ng L(-1)). Only TBBP-A was found in a treated industrial sewage at 4 ng L(-1), while BDE-99 and BDE-100 were detected on suspended solids.
Fontana, A R; Rodríguez, I; Ramil, M; Altamirano, J C; Cela, R
2011-04-22
In this work, a reliable and selective procedure for the determination of thirteen fungicides in red and white wine samples is proposed. Solid-phase extraction (SPE) and liquid chromatography (LC) tandem mass spectrometry (MS/MS), based on a hybrid quadrupole time-of-flight (QTOF) system, were used as sample preparation and determination techniques, respectively. Extraction and purification of target analytes was carried out simultaneously by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Fungicides were determined operating the electrospray source in the positive ionization mode, with MS/MS conditions adjusted to obtain at least two intense product ions per compound, or registering two transitions per species when a single product was noticed. High selective MS/MS chromatograms were extracted using a mass window of 20 ppms for each product ion. Considering external calibration as quantification technique, the overall recoveries (accuracy) of the procedure ranged between 81% and 114% for red and white wine samples (10-20 mL), spiked at different concentrations between 5 and 100 ng mL(-1). Relative standard deviations of the above data stayed below 12% and the limits of quantification (LOQs) of the method, calculated for 10 mL of wine, varied between 0.1 ng mL(-1) for cyprodinil (CYP) and 0.7 ng mL(-1) for myclobutanil (MYC). The optimized method was applied to seventeen commercial wines produced in Spain and obtained from local supermarkets. Nine fungicides were determined, at levels above the LOQs of the method, in the above samples. The maximum concentrations and the highest occurrence frequencies corresponded to metalaxyl (MET) and iprovalicarb (IPR). Copyright © 2011 Elsevier B.V. All rights reserved.
Farré, Marinella; Asperger, Daniela; Kantiani, Lina; González, Susana; Petrovic, Mira; Barceló, Damià
2008-04-01
In this work, the contributions of triclosan and its metabolite methyl triclosan to the overall acute toxicity of wastewater were studied using Vibrio fischeri. The protocol used in this paper involved various steps. First, the aquatic toxicities of triclosan and methyl triclosan were determined for standard substances, and the 50% effective concentrations (EC(50)) were determined for these compounds. Second, the toxic responses to different mixtures of triclosan, methyl triclosan, and surfactants were studied in different water matrices, i.e., Milli-Q water, groundwater and wastewater, in order to evaluate (i) the antagonistic or synergistic effects, and (ii) the influence of the water matrices. Finally, chemical analysis was used in conjunction with the toxicity results in order to assess the aquatic toxicities of triclosan and its derivative in wastewaters. In this study, the toxicities of 45 real samples corresponding to the influents and effluents from eight wastewater treatment works (WWTW) were analyzed. Thirty-one samples were from a wastewater treatment plant (WWTP) equipped with two pilot-scale membrane bioreactors (MBR), and the influent and the effluent samples after various treatments were characterized via different chromatographic approaches, including solid-phase extraction (SPE), liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), and SPE coupled to gas chromatography-mass spectrometry (GC-MS). The toxicity was determined by measuring the bioluminescence inhibition of Vibrio fischeri. In order to complete the study and to extrapolate the results to different WWTPs, the toxicity to V. fischeri of samples from seven more plants was analyzed, as were their triclosan and methyl triclosan concentrations. Good agreement was established between the overall toxicity values and concentrations of the biocides, indicating that triclosan is one of the major toxic organic pollutants currently found in domestic wastewaters.
Montesano, Camilla; Vannutelli, Gabriele; Massa, Maristella; Simeoni, Maria Chiara; Gregori, Adolfo; Ripani, Luigi; Compagnone, Dario; Curini, Roberta; Sergi, Manuel
2017-05-01
In this paper, an analytical method has been developed and validated for the analysis of new psychoactive substances (NPS) and metabolites in hair samples. The method was based on pressurized liquid extraction (PLE) followed by solid-phase extraction (SPE) clean-up and high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) analysis. To evaluate extraction efficiency and the applicability of the method, hair samples were fortified by soaking in order to obtain a good surrogate for drug users' hair; the amount of incorporated drugs related to their lipophilicity, similarly to in vivo drug incorporation. To the best of our knowledge, this is the first method that allowed for the analysis of both cathinones (5) and synthetic cannabinoids (7) in hair with a single extraction procedure and chromatographic run. A phenethylamine (2C-T-4), 4- fluorophenylpiperazine and methoxetamine were also included showing that PLE coupled to SPE clean-up was suitable for a multi-class analysis of NPS in hair. In addition, the use of PLE significantly reduced hair analysis time: decontamination, incubation, clean-up, and liquid chromatography-mass spectrometry (LC-MS) analysis were carried out in approximately 45 min. The method was fully validated according to Scientific Working Group for Forensic Toxicology (SWGTOX) and Society of Hair Testing (SoHT) guidelines. Limit of quantification (LOQ) values ranged from 8 to 50 pg mg -1 for cathinones, phenetylamines and piperazines, and from 9 to 40 pg mg -1 for synthetic cannabinoids (10 pg mg -1 for methoxetamine). Matrix effects were below 15% for all the analytes, demonstrating the effectiveness of the clean-up step. Inaccuracy was lower than 9% in terms of bias. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Barnett, Timothy C.; Liebl, David; Seymour, Lisa M.; Gillen, Christine M.; Lim, Jin Yan; LaRock, Christopher N.; Davies, Mark R.; Schulz, Benjamin L.; Nizet, Victor; Teasdale, Rohan D.; Walker, Mark J.
2014-01-01
SUMMARY Autophagy is reported to be an important innate immune defence against the intracellular bacterial pathogen Group A Streptococcus (GAS). However, the GAS strains examined to-date belong to serotypes infrequently associated with human disease. We find that the globally disseminated serotype M1T1 clone of GAS can evade autophagy and replicate efficiently in the cytosol of infected cells. Cytosolic M1T1 GAS (strain 5448), but not M6 GAS (strain JRS4), avoids ubiquitylation and recognition by the host autophagy marker LC3 and ubiquitin-LC3 adaptor proteins NDP52, p62 and NBR1. Expression of SpeB, a streptococcal cysteine protease, is critical for this process, as an isogenic M1T1 ΔspeB mutant is targeted to autophagy and attenuated for intracellular replication. SpeB degrades p62, NDP52 and NBR1 in vitro and within the host cell cytosol. These results uncover a proteolytic mechanism utilized by GAS to escape the host autophagy pathway which may underpin the success of the M1T1 clone. PMID:24331465
Paoloni, Angela; Solfrizzo, Michele; Bibi, Rita; Pecorelli, Ivan
2018-05-04
The objective of this study was to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of Ochratoxin A (OTA) and Ochratoxin α (OTα) in poultry tissues and eggs. The two toxins were extracted by a mixture of acetonitrile/water, purified with a reversed phase C18 solid phase extraction column (SPE) and determined by LC-MS/MS. The LC-MS/MS method performances were evaluated in terms of linearity in solvent and in matrix (ranged from 0.5 to 15.10 µg L -1 for OTA and from 0.60 to 17.85 µg L -1 for OTα), limit of detection (LOD), limit of quantitation (LOQ), specificity, accuracy and precision in repeatability conditions. Recovery experiments were performed by spiking poultry liver, kidney, muscle and eggs around 1 µg kg -1 and 10 µg kg -1 . LODs were 0.27 and 0.26 µg kg -1 while LOQs were fixed at 1.0 and 1.2 µg kg -1 for OTA and OTα, respectively. Main recoveries for OTA ranged from 82 to 109% and for OTα ranged from 55 to 89%. The values of within-laboratory relative standard deviation (RSD r ) were equal to or below 20%. Considering the results obtained and that all analytical performance criteria were fulfilled, the new extraction and purification method developed for OTA and OTα determination in animal tissues and eggs was found appropriate for control laboratories and research activities designed to ensure food safety.
Martin, Rafaela; Schürenkamp, Jennifer; Gasse, Angela; Pfeiffer, Heidi; Köhler, Helga
2013-05-01
A validated method for the simultaneous determination of psilocin, bufotenine, lysergic acid diethylamide and its metabolites in serum, plasma and urine using liquid chromatography-electrospray ionization/tandem mass spectrometry was developed. During the solid-phase extraction procedure with polymeric mixed-mode cation exchange columns, the unstable analytes were protected by ascorbic acid, drying with nitrogen and exclusion of light. The limits of detection and quantitation for all analytes were low. Recovery was ≥86 % for all analytes and no significant matrix effects were observed. Interday and intraday imprecisions at different concentrations ranged from 1.1 to 8.2 % relative standard deviation, bias was within ±5.3 %. Processed samples were stable in the autosampler for at least 2 days. Furthermore, freeze/thaw and long-term stability were investigated. The method was successfully applied to authentic serum and urine samples.
Wen, Chao; Wang, Dongshan; Li, Xing; Huang, Tao; Huang, Cheng; Hu, Kaifeng
2018-02-20
The anti-hyperlipidemic effects of crude crabapple extracts derived from Malus 'Red jade', Malus hupehensis (Pamp.) Rehd. and Malus prunifolia (Willd.) Borkh. were evaluated on high-fat diet induced obese (HF DIO) mice. The results revealed that some of these extracts could lower serum cholesterol levels in HF DIO mice. The same extracts were also parallelly analyzed by LC-MS in both positive and negative ionization modes. Based on the pharmacological results, 22 LC-MS variables were identified to be correlated with the anti-hyperlipidemic effects using partial least square discriminant analysis (PLS-DA) and independent samples t-test. Further, under the guidance of the bioactivity-correlated LC-MS signals, 10 compounds were targetedly isolated and enriched using UPLC-DAD-MS-SPE and identified/elucidated by NMR together with MS/MS as citric acid(1), p-coumaric acid(2), hyperoside(3), myricetin(4), naringenin(5), quercetin(6), kaempferol(7), gentiopicroside(8), ursolic acid(9) and 8-epiloganic acid(10). Among these 10 compounds, 6 compounds, hyperoside(3), myricetin(4), naringenin(5), quercetin(6), kaempferol(7) and ursolic acid(9), were individually studied and reported to indeed have effects on lowering the serum lipid levels. These results demonstrated the efficiency of this strategy for drug discovery. In contrast to traditional routes to discover bioactive compounds in the plant extracts, targeted isolation and identification of bioactive compounds in the crude plant extracts using UPLC-DAD-MS-SPE/NMR based on pharmacology-guided PLS-DA of LC-MS data brings forward a new efficient dereplicated approach to natural products research for drug discovery. Copyright © 2017 Elsevier B.V. All rights reserved.
Duan, Yan-Ping; Dai, Chao-Meng; Zhang, Ya-Lei; Ling-Chen
2013-01-03
A novel multi-templates molecularly imprinted polymer (MIP), using acidic pharmaceuticals mixture (ibuprofen (IBP), naproxen (NPX), ketoprofen (KEP), diclofenac (DFC), and clofibric acid (CA)) as the template, was prepared as solid-phase extraction (SPE) material for the quantitative enrichment of acidic pharmaceuticals in environmental samples and off-line coupled with liquid chromatography-mass spectrometry (LC/MS/MS). Washing solvent was optimized in terms of kind and volume for removing the matrix constituents nonspecifically adsorbed on the MIP. When 1L of water sample spiked at 1μg/L was loaded onto the cartridge, the binding capacity of the MIP cartridge were 48.7μg/g for KEP, 60.7μg/g for NPX, 52μg/g for CA, 61.3μg/g for DFC and 60.7μg/g for IBP, respectively, which are higher than those of the commercial single template MIP in organic medium (e.g. toluene) reported in the literature. Recoveries of the five acidic pharmaceuticals extracted from 1L of real water samples such as lake water and wastewater spiked at 1μg/L were more than 95%. The recoveries of acidic pharmaceuticals extracted from 10-g sediment sample spiked at the 10ng/g level were in the range of 77.4-90.6%. To demonstrate the potential of the MIP obtained, a comparison with commercial C18 SPE cartridge was performed. Molecularly imprinted solid-phase extraction (MISPE) cartridge showed higher recoveries than commercial C18 SPE cartridge for acidic pharmaceuticals. These results showed the suitability of the MISPE method for the selective extraction of a group of structurally related compounds such as acidic pharmaceuticals. Copyright © 2012 Elsevier B.V. All rights reserved.
Meyer, M.T.; Lee, E.A.; Ferrell, G.M.; Bumgarner, J.E.; Varns, Jerry
2007-01-01
This report describes the performance of an offline tandem solid-phase extraction (SPE) method and an online SPE method that use liquid chromatography/mass spectrometry for the analysis of 23 and 35 antibiotics, respectively, as used in several water-quality surveys conducted since 1999. In the offline tandem SPE method, normalized concentrations for the quinolone, macrolide, and sulfonamide antibiotics in spiked environmental samples averaged from 81 to 139 percent of the expected spiked concentrations. A modified standard-addition technique was developed to improve the quantitation of the tetracycline antibiotics, which had 'apparent' concentrations that ranged from 185 to 1,200 percent of their expected spiked concentrations in matrix-spiked samples. In the online SPE method, normalized concentrations for the quinolone, macrolide, sulfonamide, and tetracycline antibiotics in matrix-spiked samples averaged from 51 to 142 percent of their expected spiked concentrations, and the beta-lactam antibiotics in matrix-spiked samples averaged from 22 to 76 percent of their expected spiked concentration. Comparison of 44 samples analyzed by both the offline tandem SPE and online SPE methods showed 50 to 100 percent agreement in sample detection for overlapping analytes and 68 to 100 percent agreement in a presence-absence comparison for all analytes. The offline tandem and online SPE methods were compared to an independent method that contains two overlapping antibiotic compounds, sulfamethoxazole and trimethoprim, for 96 and 44 environmental samples, respectively. The offline tandem SPE showed 86 and 92 percent agreement in sample detection and 96 and 98 percent agreement in a presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. The online SPE method showed 57 and 56 percent agreement in sample detection and 72 and 91 percent agreement in presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. A linear regression with an R2 of 0.91 was obtained for trimethoprim concentrations, and an R2 of 0.35 was obtained for sulfamethoxazole concentrations determined from samples analyzed by the offline tandem SPE and online SPE methods. Linear regressions of trimethoprim and sulfamethoxazole concentrations determined from samples analyzed by the offline tandem SPE method and the independent M3 pharmaceutical method yielded R2 of 0.95 and 0.87, respectively. Regressed comparison of the offline tandem SPE method to the online SPE and M3 methods showed that the online SPE method gave higher concentrations for sulfamethoxazole and trimethoprim than were obtained from the offline tandem SPE or M3 methods.
IDEOM: an Excel interface for analysis of LC-MS-based metabolomics data.
Creek, Darren J; Jankevics, Andris; Burgess, Karl E V; Breitling, Rainer; Barrett, Michael P
2012-04-01
The application of emerging metabolomics technologies to the comprehensive investigation of cellular biochemistry has been limited by bottlenecks in data processing, particularly noise filtering and metabolite identification. IDEOM provides a user-friendly data processing application that automates filtering and identification of metabolite peaks, paying particular attention to common sources of noise and false identifications generated by liquid chromatography-mass spectrometry (LC-MS) platforms. Building on advanced processing tools such as mzMatch and XCMS, it allows users to run a comprehensive pipeline for data analysis and visualization from a graphical user interface within Microsoft Excel, a familiar program for most biological scientists. IDEOM is provided free of charge at http://mzmatch.sourceforge.net/ideom.html, as a macro-enabled spreadsheet (.xlsb). Implementation requires Microsoft Excel (2007 or later). R is also required for full functionality. michael.barrett@glasgow.ac.uk Supplementary data are available at Bioinformatics online.
Socas-Rodríguez, Bárbara; González-Sálamo, Javier; Hernández-Borges, Javier; Rodríguez Delgado, Miguel Ángel
2016-05-01
In this work, a simple and environmental friendly methodology has been developed for the analysis of a group of six mycotoxins with estrogenic activity produced by Fusarium species (i.e. zearalanone, zearalenone, α-zearalanol, β-zearalanol, α-zearalenol, and β-zearalenol), using microdispersive SPE the symbol micro should de before dSPE with multiwalled carbon nanotubes as sorbent. Separation, determination, and quantification were achieved by HPLC coupled to ion trap MS with an ESI interface. Parameters affecting the extraction efficiency of µ-dSPE such as pH of the sample, amount of multiwalled carbon nanotubes, and type and volume of elution solvent, were studied and optimized. The methodology was validated for mineral, pond, and wastewater as well as for powdered infant milk using 17β-estradiol-2,4,16,16,17-d5 (17β-E2 -D5 ) as internal standard, obtaining recoveries ranging from 85 to 120% for the three types of water samples and from 77 to 115% for powdered infant milk. RSD values were lower than 10%. The LOQs achieved were in the range 0.05-2.90 μg/L for water samples and 2.02-31.9 μg/L for powdered infant milk samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Saeidi, Iman; Barfi, Behruz; Payrovi, Moazameh; Feizy, Javid; Sheibani, Hojat A; Miri, Mina; Ghollasi Moud, Farahnaz
2015-01-01
With polyamide (PA) as an efficient sorbent for solid phase extraction (SPE) of Sudan dyes II, III and Red 7B from saffron and urine, their determination by HPLC was performed. The optimum conditions for SPE were achieved using 7 mL methanol/water (1:9, v/v, pH 7) as the washing solvent and 3 mL tetrahydrofuran for elution. Good clean-up and high (above 90%) recoveries were observed for all the analytes. The optimized mobile phase composition for HPLC analysis of these compounds was methanol-water (70:30, v/v). The SPE parameters, such as the maximum loading capacity and breakthrough volume, were also determined for each analyte. The limits of detection (LODs), limits of quantification (LOQs), linear ranges and recoveries for the analytes were 4.6-6.6 microg/L, 13.0-19.8 microg/L, 13.0-5000 microg/L (r2>0.99) and 92.5%-113.4%, respectively. The precisions (RSDs) of the overall analytical procedure, estimated by five replicate measurements for Sudan II, III and Red 7B in saffron and urine samples were 2.3%, 1.8% and 3.6%, respectively. The developed method is simple and successful in the application to the determination of Sudan dyes in saffron and urine samples with HPLC coupled with UV detection.
Chiap, P; Rbeida, O; Christiaens, B; Hubert, Ph; Lubda, D; Boos, K S; Crommen, J
2002-10-25
A new kind of silica-based restricted-access material (RAM) has been tested in pre-columns for the on-line solid-phase extraction (SPE) of basic drugs from directly injected plasma samples before their quantitative analysis by reversed-phase liquid chromatography (LC), using the column switching technique. The outer surface of the porous RAM particlescontains hydrophilic diol groups while sulphonic acid groups are bound to the internal surface, which gives the sorbent the properties of a strong cation exchanger towards low molecular mass compounds. Macromolecules such as proteins have no access to the internal surface of the pre-column due to their exclusion from the pores and are then flushed directly out. The retention capability of this novel packing material has been tested for some hydrophilic basic drugs, such as atropine, fenoterol, ipratropium, procaine, sotalol and terbutaline, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The elution profiles of the different compounds and the plasma matrix as well as the time needed for the transfer of the analytes from the pre-column to the analytical column were determined in order to deduce the most suitable conditions for the clean-up step and develop on-line methods for the LC determination of these compounds in plasma. The cationic exchange sorbent was also compared to another RAM, namely RP-18 ADS (alkyl diol silica) sorbent with respect to retention capability towards basic analytes.
Wen, Ching-Hsuan; Lin, Shu-Ling; Fuh, Ming-Ren
2017-03-01
In this study, the salting-out solvent extraction and dispersive solid-phase extraction (dSPE) clean-up steps in QuEChERS (quick, easy, cheap, effective, rugged, and safe) method were optimized to reduce matrix effect and efficiently extract target sulfonamides from a variety of edible animal tissues. The extracted sulfonamides were then analyzed using liquid chromatography tandem mass spectrometry (LC-MS/MS). Good extraction recoveries (74.0-100.3% in five different sources of animal tissues; n=3) with acceptable matrix effect (<10%, except for liver samples) were obtained using the proposed method. For the first time, a commercial ND-lipids cartridge was used to remove hydrophobic matrix components from fat-rich animal tissues in the clean-up step of QuEChERS. In addition, good linearity (0.125-12.5ngg -1 ) was observed using matrix-matched calibration (in beef). Limits of detection (LODs) were estimated at 0.01-0.03ngg -1 in beef, pork, and chicken samples. For beef tripe and pig liver samples, the LODs were in the range of 0.02-0.04ngg -1 . Good intra-day/inter-day precision (1.0-10.5%/0.4-8.0%) and accuracy (95.2-107.2%/97.8-102.1%) were also achieved using the modified QuEChERS for sample pretreatment. The applicability of the modified QuEChERS-LC-MS/MS method was demonstrated by determining the occurrence of target sulfonamides in various edible animal tissues for potential food safety analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Economou, Anastasios; Petraki, Olympia; Tsipi, Despina; Botitsi, Eleni
2012-08-15
This work reports a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for identification and quantification of seven sulfonamides, trimethoprim and dapsone in honey. The method is based on a solid-phase extraction (SPE) step of the target analytes with Oasis HLB cartridges after acidic hydrolysis of the honey sample to liberate the sugar-bound sulfonamides. Analysis was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive electro-spray ionization (ESI) mode with two different isotopically labeled internal standards with the view to improve the quantitative performance of the method. The method validation has been performed according to the Commission Decision 2002/657/EC; the average recoveries, measured at three concentration levels (1.5, 2.5 and 5.0 μg kg(-1)), have been estimated in the range 70 to 106% while the respective % relative standard deviations of the within-laboratory reproducibility ranged from 6 to 18%. Mean values of the expanded uncertainties calculated were in the range 22-41% at the 99% confidence level. Decision limit (CCα) and detection capability (CCβ) values were in the ranges 0.4-0.9 and 0.7-1.4 μg kg(-1), respectively. Matrix effects have been investigated demonstrating a moderate signal suppression/enhancement for most of the target compounds. The method described has been successfully applied to the analysis of honey samples; sulfamethoxazole, sulfathiazole and trimethoprim were detected in some cases. Copyright © 2012 Elsevier B.V. All rights reserved.
Shang, Xiaohong; Zhao, Yunfeng; Zhang, Lei; Li, Xiaowei; Wu, Yongning
2011-07-01
The improvement method was developed for methylmercury determination using liquid chromatography online coupled with cold vapor atomic fluorescence spectrometry (LC-CV-AFS). Cysteine was used as complexing agent in mobile phase instead of mercaptoethanol. Under the optimized conditions, baseline separation of mercury species could be achieved within 8 min on a C18 column with a mobile phase of 5% (v/v) acetonitrile-1 g/L L-cysteine-50 mmol/L ammonium acetate aqueous solution. The linear range of calibration curve of methylmercury was 1-50 microg/L and the limit of detection (S/N = 3) for methylmercury was 0.3 microg/L. Ultrasonication assisted hydrochloric acid extraction was used to extract methylmercury from seafood samples. The sample extract was cleaned up by a C18 solid phase extraction (SPE) cartridge. For validation of the method, certified reference materials and spiked seafood samples were analyzed. The determined methylmercury contents of certified reference materials NIST1566b, BCR464 and GBW10029 agreed well with the certified values. The determined methylmercury values for Food Analysis Performance Assessment Scheme (FAPAS) sample 07115 were satisfied. The recoveries of methylmercury in seafood samples at three spiked levels (10, 50 and 500 microg/kg) ranged from 89% to 112%, including cooked seafood food. The precision of the method based on relative standard deviation (RSD) was not more than 7%. The present method of LC-CV-AFS is accurate, sensitive, simple, and can meet the demand of methylmercury determination in seafood.
Boison, Joe O; Asea, Philip A; Matus, Johanna L
2012-08-01
A new and sensitive multi-residue method (MRM) with detection by LC-MS/MS was developed and validated for the screening, determination, and confirmation of residues of 7 nitroimidazoles and 3 of their metabolites in turkey muscle tissues at concentrations ≥ 0.05 ng/g. The compounds were extracted into a solvent with an alkali salt. Sample clean-up and concentration was then done by solid-phase extraction (SPE) and the compounds were quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The characteristic parameters including repeatability, selectivity, ruggedness, stability, level of quantification, and level of confirmation for the new method were determined. Method validation was achieved by independent verification of the parameters measured during method characterization. The seven nitroimidazoles included are metronidazole (MTZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), ipronidazole (IPR), and carnidazole (CNZ). It was discovered during the single laboratory validation of the method that five of the seven nitroimidazoles (i.e. metronidazole, dimetridazole, tinidazole, ornidazole and ipronidazole) and the 3 metabolites (1-(2-hydroxyethyl)-2-hydroxymethyl-5-nitroimidazole (MTZ-OH), 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the common metabolite of ronidazole and dimetridazole), and 1-methyl-2-(2'-hydroxyisopropyl)-5-nitroimidazole (IPR-OH) included in this study could be detected, confirmed, and quantified accurately whereas RNZ and CNZ could only be detected and confirmed but not accurately quantified. © Her Majesty the Queen in Right of Canada as Represented by the Minister of Agriculture and Agri-food Canada 2012.
Two-Dimensional Liquid Chromatography Analysis of Polystyrene/Polybutadiene Block Copolymers.
Lee, Sanghoon; Choi, Heejae; Chang, Taihyun; Staal, Bastiaan
2018-05-15
A detailed characterization of a commercial polystyrene/polybutadiene block copolymer material (Styrolux) was carried out using two-dimensional liquid chromatography (2D-LC). The Styrolux is prepared by statistical linking reaction of two different polystyrene- block-polybutadienyl anion precursors with a multivalent linking agent. Therefore, it is a mixture of a number of branched block copolymers different in molecular weight, composition, and chain architecture. While individual LC analysis, including size exclusion chromatography, interaction chromatography, or liquid chromatography at critical condition, is not good enough to resolve all the polymer species, 2D-LC separations coupling two chromatography methods were able to resolve all polymer species present in the sample; at least 13 block copolymer species and a homopolystyrene blended. Four different 2D-LC analyses combining a different pair of two LC methods provide their characteristic separation results. The separation characteristics of the 2D-LC separations are compared to elucidate the elution characteristics of the block copolymer species.
High-Throughput Serum 25-Hydroxy Vitamin D Testing with Automated Sample Preparation.
Stone, Judy
2016-01-01
Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 % formic acid in acetonitrile, is added and mixed with a 96-channel ALH. After a 4-min delay for larger precipitates to settle to the bottom of the plate, the upper 36 % of the precipitate/supernatant mix is transferred with the 96-channel ALH to a Sigma Hybrid SPE(®) plate and vacuumed through for removal of phospholipids and precipitated proteins. The filtrate is collected in a second 96-well plate (collection plate) which is foil-sealed, placed in the autosampler (ALS), and injected into a multiplexed LC-MS/MS system running AB Sciex Cliquid(®) and MPX(®) software. Two Shimadzu LC stacks, with multiplex timing controlled by MPX(®) software, inject alternately to one AB Sciex API-5000 MS/MS using positive atmospheric pressure chemical ionization (APCI) and a 1.87 min water/acetonitrile LC gradient with a 2.1 × 20 mm, 2.7 μm, C18 fused core particle column (Sigma Ascentis Express). LC-MS/MS through put is ~44 samples/h/LC-MS/MS system with dual-LC channel multiplexing. Plate maps are transferred electronically from the ALH and reformatted into LC-MS/MS sample table format using the Data Innovations LLC (DI) Instrument Manager middleware application. Before collection plates are loaded into the ALS, the plate bar code is manually scanned to download the sample table from the DI middleware to the LC-MS/MS. After acquisition-LC-MS/MS data is analyzed with AB Sciex Multiquant(®) software using customized queries, and then results are transferred electronically via a DI interface to the LIS. 2500 samples/day can be extracted by two analysts using four ALHs in 4-6 h. LC-MS/MS analysis of those samples on three dual-channel LC multiplexed LC-MS/MS systems requires 19-21 h and data analysis can be done by two analysts in 4-6 h.
Wang, Shuo; Li, Shuming; Zhang, Xiangming; Wei, Yunfang; Zhang, Meiyun; Zhang, Jing
2015-07-01
To develop a comprehensive method for simultaneous analysis of sulfonamides and their metabolites in drinking water by high performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Different solid-phase extraction columns were compared with respect to the recovery of target drugs from drinking water. The drinking water samples were adjusted to 3 by HCl and purified by a mix mode cation-ion exchange solid-phase extraction (SPE), following determination using LG-MS/MS. A total of 21 sulfonamides were separated by a C15 column (2.1 mm x 100 mm, 1.7 µm) and analyzed under positive ion mode with multi-reaction monitoring. The matrix-matched external standard calibration was used for quantification. The method quantification limits for 21 analytes were 0.03-0.63 ng/L with overall recoveries of 50.1%-114.9%, and the relative standard deviations less than 20%. The method was finally used to analyze sulfonamides in drinking water in Beijing, and 5 target compounds (sulfadiazine, sulfathiazole, sulfapyridine, trimethoprim and sulfamethazine) were detected at a concentration range of 0.08-32.54 ng/L. This method could be applied in simultaneous analysis of sulfonamides and their metabolites in drinking water samples.
Yang, Yunjia; Yin, Jie; Yang, Yi; Zhou, Naiyuan; Zhang, Jing; Shao, Bing; Wu, Yongning
2012-07-15
As a homologue of bisphenol A (BPA), there is concern about the potential reproductive and developmental toxicity of bisphenol AF (BPAF) based on in vitro tests. In this study, a simple and universal analytical method was developed for the determination of trace BPAF in various tissues and excreta of rats after they were orally dosed. The samples were hydrolyzed with glucuronidase/arylsulfatase followed by ultrasonic extraction with acetonitrile. The crude extract was purified with a mixed-mode anion exchange (Oasis MAX) solid-phase extraction (SPE) cartridge. Separation and quantification was then conducted by ultra-high-pressure liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) in negative ionization mode. The recoveries at three fortification levels in different biological samples were from 71.0% to 102.3% with relative standard deviations no more than 13.2% (n=6). The quantification limits of the method were from 0.5 μg/kg to 3 μg/kg depending on the matrix. This method was successfully applied to the determination of BPAF in tissues, serum, urine and feces of orally dosed rats. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Yan; Wang, Youchao; Tang, Chuanjiang; Nie, Jingmei; Xu, Chengtao
2018-01-01
Perfluorinated compounds (PFCs), used to provide water, oil, grease, heat and stain repellency to a range of textile and other products, have been found to be persistent in the environment and are associated with adverse effects on humans and wildlife. This study presents the development and validation of an analytical method to determine the simultaneous presence of eleven PFCs in leather using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The perfluorinated compounds were primarily extracted from the samples by a liquid extraction procedure by ultrasonic, in which the parameters were optimized. Then the solid-phase extraction (SPE) is the most important advantages of the developed methodology. The sample volume and elution conditions were optimized by means of an experimental design. The proposed method was applied to determine the PFCs in leather, where the detection limits of the eleven compounds were 0.09-0.96 ng/L, and the recoveries of all compounds spiked at 5 ng/L concentration level were in the range of 65-96%, with a better RSD lower than 19% (n = 7).
2007-06-01
T ACanadaY Approved for PublicR Distribution Uln& Liquid Chromatography Electrospray Ionization Mass Spectrometric ( LC -ESI- MS) and Desorption...consumer products with chemical warfare agents or other toxic chemicals. Liquid chromatography electrospray ionization mass spectrometry ( LC -ESI-MS) and...house LC -ESI-MS and LC -ESI-MS/MS methods were evaluated for the determination of chemical warfare agents in spiked bottled water samples. The
NASA Technical Reports Server (NTRS)
Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi
2008-01-01
Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.
The Effect of Ambient Ozone on Unsaturated Tear Film Wax Esters.
Paananen, Riku O; Rantamäki, Antti H; Parshintsev, Jevgeni; Holopainen, Juha M
2015-12-01
Tear film lipid layer (TFLL) is constantly exposed to reactive ozone in the surrounding air, which may have detrimental effects on ocular health. Behenyl oleate (BO), a representative tear film wax ester, was used to study the reaction with ozone at the air-water interface. Time-dependent changes in mean molecular area of BO monolayers were measured at different ozone concentrations and surface pressures. In addition, the effect of ascorbic acid on the reaction rate was determined. Reaction was followed using thin-layer chromatography and reaction products were identified using liquid chromatography-electrospray ionization mass spectrometry (LC-MS). Tear fluid samples from healthy subjects were analyzed with LC-MS for any ozonolysis reaction products. Behenyl oleate was found to undergo rapid ozonolysis at the air-water interface at normal indoor ozone concentrations. The reaction was observed as an initial expansion followed by a contraction of the film area. Ascorbic acid was found to decrease the rate of ozonolysis. Main reaction products were identified as behenyl 9-oxononanoate and behenyl 8-(5-octyl-1,2,4-trioxolan-3-yl)octanoate. Similar ozonolysis products were not detected in the tear fluid samples. At the air-water interface, unsaturated wax esters react readily with ozone in ambient air. However, no signs of ozonolysis products were found in the tear fluid. This is most likely due to the antioxidant systems present in tear fluid. Last, the results show that ozonolysis needs to be controlled in future surface chemistry studies on tear film lipids.
Chang, Ying-Chia; Chen, Wen-Ling; Bai, Fang-Yu; Chen, Pau-Chung; Wang, Gen-Shuh; Chen, Chia-Yang
2012-01-01
For this study, we developed methods of determining ten perfluorinated chemicals in drinking water, milk, fish, beef, and pig liver using high-flow automated solid-phase extraction (SPE) and ultra-high performance liquid chromatography/tandem mass spectrometry. The analytes were separated on a core-shell Kinetex C18 column. The mobile phase was composed of methanol and 10-mM N-methylmorpholine. Milk was digested with 0.5 N potassium hydroxide in Milli-Q water, and was extracted with an Atlantic HLB disk to perform automated SPE at a flow rate ranged from 70 to 86 mL/min. Drinking water was directly extracted by the SPE. Solid food samples were digested in alkaline methanol and their supernatants were diluted and also processed by SPE. The disks were washed with 40% methanol/60% water and then eluted with 0.1% ammonium hydroxide in methanol. Suppression of signal intensity of most analytes by matrixes was lower than 50%; it was generally lower in fish and drinking water but higher in liver. Most quantitative biases and relative standard deviations were lower than 15%. The limits of detection for most analytes were sub-nanograms per liter for drinking water and sub-nanograms per gram for solid food samples. This method greatly shortened the time and labor needed for digestion, SPE, and liquid chromatography. This method has been applied to analyze 14 types of food samples. Perfluorooctanoic acid was found to be the highest among the analytes (median at 3.2-64 ng/g wet weight), followed by perfluorodecanoic acid (0.7-25 ng/g) and perfluorododecanoic acid (0.6-15 ng/g).
Kinyua, Juliet; Covaci, Adrian; Maho, Walid; McCall, Ann-Kathrin; Neels, Hugo; van Nuijs, Alexander L N
2015-09-01
Sewage-based epidemiology (SBE) employs the analysis of sewage to detect and quantify drug use within a community. While SBE has been applied repeatedly for the estimation of classical illicit drugs, only few studies investigated new psychoactive substances (NPS). These compounds mimic effects of illicit drugs by introducing slight modifications to chemical structures of controlled illicit drugs. We describe the optimization, validation, and application of an analytical method using liquid chromatography coupled to positive electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of seven NPS in sewage: methoxetamine (MXE), butylone, ethylone, methylone, methiopropamine (MPA), 4-methoxymethamphetamine (PMMA), and 4-methoxyamphetamine (PMA). Sample preparation was performed using solid-phase extraction (SPE) with Oasis MCX cartridges. The LC separation was done with a HILIC (150 x 3 mm, 5 µm) column which ensured good resolution of the analytes with a total run time of 19 min. The lower limit of quantification (LLOQ) was between 0.5 and 5 ng/L for all compounds. The method was validated by evaluating the following parameters: sensitivity, selectivity, linearity, accuracy, precision, recoveries and matrix effects. The method was applied on sewage samples collected from sewage treatment plants in Belgium and Switzerland in which all investigated compounds were detected, except MPA and PMA. Furthermore, a consistent presence of MXE has been observed in most of the sewage samples at levels higher than LLOQ. Copyright © 2015 John Wiley & Sons, Ltd.
High-field asymmetric waveform ion mobility spectrometry for mass spectrometry-based proteomics.
Swearingen, Kristian E; Moritz, Robert L
2012-10-01
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve the detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, the authors review recent developments in LC-FAIMS-MS and its application to MS-based proteomics.
ERIC Educational Resources Information Center
O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep
2009-01-01
Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…
Xu, Yinyan; Huang, Xinyan; Xie, Juan; Chen, Yanni; Fu, Jing; Wang, Li
2017-09-01
Autophagy, identified as type II programmed cell death, has already been known to be involved in the pathophysiology of preeclampsia (PE), which is a gestational disease with high morbidity. The present study aims to investigate the functional role of let-7i, a miRNA, in trophoblastic autophagy. Placental tissue used in this study was collected from patients with severe preeclampsia (SPE) or normal pregnant women. A decreased level of let-7i was found in placenta of SPE. In addition, autophagic vacuoles were observed in SPE and the expression of microtubule associated protein 1 light chain 3 (LC3) II/I was elevated. In vitro, let-7i mimics suppressed the autophagic activities in human HTR-8/SVneo trophoblast cell line (HTR-8) and human placental choriocarcinoma cell line JEG-3, whereas let-7i inhibitor enhanced the activities. As a potential target of let-7i, autophagy-related 4B cysteine peptidase (Atg4B) had an increased expression level in SPE. As expected, the increased expression of Atg4B was negatively regulated by let-7i using dual luciferase reporter assay. Furthermore, these trophoblast-like cells transfected with the let-7i mimic or inhibitors resulted in a significant change of Atg4B in both mRNA and protein level. More importantly, Atg4B overexpression could partly reverse let-7i mimic-reduced LC3II/I levels; whereas Atg4B silencing partly attenuated let-7i inhibitor-induced the level of LC3II/I expression. Taken together, these findings suggest that let-7i is able to regulate autophagic activity via regulating Atg4B expression, which might contribute to the pathogenesis of PE. J. Cell. Physiol. 232: 2581-2589, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Instrument platforms for nano liquid chromatography.
Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav
2015-11-20
The history of liquid chromatography started more than a century ago and miniaturization and automation are two leading trends in this field. Nanocolumn liquid chromatography (nano LC) and largely synonymous capillary liquid chromatography (capillary LC) are the most recent results of this process where miniaturization of column dimensions and sorbent particle size play crucial role. Very interesting results achieved in the research of extremely miniaturized LC columns at the end of the last century lacked distinctive raison d'être and only advances in mass spectrometry brought a real breakthrough. Configuration of nano LC-electrospray ionization mass spectrometry (LC-ESI-MS) has become a basic tool in bioanalytical chemistry, especially in proteomics. This review discusses and summarizes past and current trends in the realization of nano liquid chromatography (nano LC) platforms. Special attention is given to the mobile phase delivery under nanoflow rates (isocratic, gradient) and sample injection to the nanocolumn. Available detection techniques applied in nano LC separations are also briefly discussed. We followed up the key themes from the original scientific reports over gradual improvements up to the contemporary commercial solutions. Copyright © 2015 Elsevier B.V. All rights reserved.
Yu, Shuo; Yang, Bo; Yan, Liangping; Dai, Qiuyun
2017-07-28
α-conotoxin GI, a short peptide toxin in the venom of Conus geographus , is composed of 13 amino acids and two disulfide bonds. It is the most toxic component of Conus geographus venom with estimated lethal doses of 0.029-0.038 mg/kg for humans. There is currently no reported analytical method for this toxin. In the present study, a sensitive detection method was developed to quantify GI in human plasma using a solid-phase extraction (SPE) column (polystyrene-divinyl benzene copolymer) combined with liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) in the multiple reaction monitoring (MRM) mode. The plasma samples were treated with a protein precipitating solvent (methanol: acetonitrile = 50:50, v / v ). GI in the solvent was efficiently extracted with an SPE column and was further separated by a Grace Alltima HP C 18 (50 × 2.1 mm, 5 μm) column at a flow rate of 0.4 mL/min. Water (with 2% methanol) acetonitrile (with 0.1% acetic acid) was selected as the mobile phase combination used in a linear gradient system. α-Conotoxin GI was analyzed by an API 4000 triple quadrupole mass spectrometer. In the method validation, the linear calibration curve in the range of 2.0 to 300.0 ng/mL had correlation coefficients ( r ) above 0.996. The recovery was 57.6-66.8% for GI and the internal standard. The lower limit of quantification (LLOQ) was 2 ng/mL. The intra- and inter-batch precisions were below 6.31% and 8.61%, respectively, and the accuracies were all within acceptance. GI was stable in a bench-top autosampler through long-term storage and freeze/thaw cycles. Therefore, this method is specific, sensitive and reliable for quantitative analysis of α-conotoxin GI in human plasma.
Uclés, Ana; Herrera López, Sonia; Dolores Hernando, Maria; Rosal, Roberto; Ferrer, Carmen; Fernández-Alba, Amadeo R
2015-11-01
The use of yttria-stabilized zirconium dioxide nanoparticles as d-SPE clean-up sorbent for a rapid and sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the determination of post-harvest fungicides (carbaryl, carbendazim, chlorpropham, diphenylamine, ethoxyquin, flutriafol, imazalil, iprodione, methomyl, myclobutanil, pirimiphos-methyl, prochloraz, pyrimethanil, thiabendazole, thiophanate-methyl and tolclofos-methyl) in orange and pear samples has been evaluated and validated. The sample preparation was a modification of the QuEChERS extraction method using yttria-stabilized zirconium dioxide and multi-walled carbon nanotubes (MWCNTs) nanoparticles as the solid phase extraction (d-SPE) clean-up sorbents prior to injecting the ten-fold diluted extracts into the LC system. By using the yttria-stabilized zirconium dioxide extraction method, more recoveries in the 70-120% range were obtained - thus this method was used for the validation. Quantification was carried out using a matrix-matched calibration curve which was linear in the 1-500 µg kg(-1) range for almost all the pesticides studied. The validated limit of quantification was 10 µg kg(-1) for most of the studied compounds, except chlorpropham, ethoxyquin and thiophanate-methyl. Pesticide recoveries at the 10 and 100 µg kg(-1) concentration levels were satisfactory, with values between 77% and 120% and relative standard deviations (RSD) lower than 10% (n=5). The developed method was applied for the determination of selected fungicides in 20 real orange and pear samples. Four different pesticide residues were detected in 10 of these commodities; 20% of the samples contained pesticide residues at a quantifiable level (equal to or above the LOQs) for at least one pesticide residue. The most frequently-detected pesticide residues were: carbendazim, thiabendazole and imazalil-all were below the MRL. The highest concentration found was imazalil at 1175 µg kg(-1) in a pear sample. Copyright © 2015 Elsevier B.V. All rights reserved.
Advanced liquid chromatography-mass spectrometry interface based on electron ionization.
Cappiello, A; Famiglini, G; Pierini, E; Palma, P; Trufelli, H
2007-07-15
Major progress in interfacing liquid chromatography and electron ionization mass spectrometry is presented. The minimalism of the first prototype, called the Direct-EI interface, has been widely refined, improved, and applied to modern instrumentation. The simple interfacing principle is based on the straight connection between a nanoHPLC system and a mass spectrometer equipped with an EI source forming a solid and reliable unicum resembling the immediacy and straightforwardness of GC/MS. The interface shows a superior performance in the analysis of small-medium molecular weight compounds, especially when compared to its predecessors, and a unique trait that excels particularly in the following aspects: (1) It delivers high-quality, fully library matchable mass spectra of most sub-1 kDa molecules amenable by HPLC. (2) It is a chemical ionization free interface (unless operated intentionally) with accurate reproduction of the expected isotope ion abundances. (3) Response is never influenced by matrix components in the sample or in the mobile phase (nonvolatile salts are also well accepted). A deep evaluation of these aspects is presented and discussed in detail. Other characteristics of the interface performance such as limits of detections, range of linear response, and intra- and interday signal stability were also considered. The usefulness of the interface has been tested in a few real-world applications where matrix components played a detrimental role with other LC/MS techniques.
Yin, Yong-guang; Chen, Ming; Peng, Jin-feng; Liu, Jing-fu; Jiang, Gui-bin
2010-06-15
A novel and simple solid phase extraction (SPE)-high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) method was developed for determination of inorganic mercury (IHg), methylmercury MeHg and ethylmercury (EtHg) in water samples in the present work. The procedure involves pre-functionalization of the commercially available C18 SPE column with dithizone, loading water sample, displacement elution of mercury species by Na(2)S(2)O(3) solution, followed by HPLC-ICP-MS determination. Characterization and optimization of operation parameters of this new SPE procedure were discussed, including eluting reagent selection, concentration of eluting reagent, volume of eluting reagent, effect of NaCl and humic acid in sample matrix. At optimized conditions, the detection limits of mercury species for 100mL water sample were about 3ngL(-1) and the average recoveries were 93.7, 83.4, and 71.7% for MeHg, IHg and EtHg, respectively, by spiking 0.2microgL(-1) mercury species into de-ion water. Stability experiment reveals that both the dithizone-functionalized SPE cartridge and the mercury species incorporated were stable in the storage procedure. These results obtained demonstrate that SPE-HPLC-ICP-MS is a simple and sensitive technique for the determination of mercury species at trace level in water samples with high reproducibility and accuracy.
Chen, Jing; Liu, Zhaojin; An, Baochao; Lu, Yan; Xu, Qun
2012-10-01
An on-line solid phase extraction (SPE) system was used to eliminate the interferences sufficiently and fulfill the simple and sensitive determination of diquat and paraquat in tap and pond water. This on-line SPE system used two SPE cartridges. One was an Acclaim Mixed-Mode WAX-1 cartridge for the elimination of anionic interferences; the other one was an Acclaim Mixed-Mode WCX-1 cartridge for the enrichment of diquat and paraquat and the elimination of co-enriched cationic interferences. The baseline separation of diquat and paraquat was achieved on an Acclaim Trinity P1 column. A dual-gradient high performance liquid chromatographic (HPLC) system provided an efficient platform to fulfill the on-line SPE and separation, and the system operated under automatic control of chromatography data system software. The complete analysis only required 16 min, and the detection limits of the method were 0.12 microg/L for diquat and 0.10 microg/L for paraquat. The method is simple, rapid and sensitive, and can be applied to the determination of diquat and paraquat in drinking water and environmental water.
Gauw, R D; Stoffolano, P J; Kuhlenbeck, D L; Patel, V S; Garver, S M; Baker, T R; Wehmeyer, K R
2000-07-21
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%.
Ostman, Pekka; Jäntti, Sirkku; Grigoras, Kestas; Saarela, Ville; Ketola, Raimo A; Franssila, Sami; Kotiaho, Tapio; Kostiainen, Risto
2006-07-01
A miniaturized nebulizer chip for capillary liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (capillary LC-microchip APCI-MS) is presented. The APCI chip consists of two wafers, a silicon wafer and a Pyrex glass wafer. The silicon wafer has a DRIE etched through-wafer nebulizer gas inlet, an edge capillary insertion channel, a stopper, a vaporizer channel and a nozzle. The platinum heater electrode and pads for electrical connection were patterned on to the Pyrex glass wafer. The two wafers were joined by anodic bonding, creating a microchip version of an APCI-source. The sample inlet capillary from an LC column is directly connected to the vaporizer channel of the APCI chip. The etched nozzle in the microchip forms a narrow sample plume, which is ionized by an external corona needle, and the formed ions are analyzed by a mass spectrometer. The nebulizer chip enables for the first time the use of low flow rate separation techniques with APCI-MS. The performance of capillary LC-microchip APCI-MS was tested with selected neurosteroids. The capillary LC-microchip APCI-MS provides quantitative repeatability and good linearity. The limits of detection (LOD) with a signal-to-noise ratio (S/N) of 3 in MS/MS mode for the selected neurosteroids were 20-1000 fmol (10-500 nmol l(-1)). LODs (S/N = 3) with commercial macro APCI with the same compounds using the same MS were about 10 times higher. Fast heat transfer allows the use of the optimized temperature for each compound during an LC run. The microchip APCI-source provides a convenient and easy method to combine capillary LC to any API-MS equipped with an APCI source. The advantages and potentials of the microchip APCI also make it a very attractive interface in microfluidic APCI-MS.
Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M
2015-11-20
The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. Copyright © 2015 Elsevier B.V. All rights reserved.
Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples
USDA-ARS?s Scientific Manuscript database
High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-...
Sandra, Koen; Steenbeke, Mieke; Vandenheede, Isabel; Vanhoenacker, Gerd; Sandra, Pat
2017-11-10
In recent years, two-dimensional liquid chromatography (2D-LC) has seen an enormous evolution and one of the fields where it is being widely adopted is in the analysis of therapeutic monoclonal antibodies (mAbs). We here further add to the many flavours of this powerful technology. Workflows based on heart-cutting (LC-LC) and comprehensive (LC×LC) 2D-LC are described that allow to guide the clone selection process in mAb and biosimilar development. Combining Protein A affinity chromatography in the first dimension with size exclusion (SEC), cation exchange (CEX) or reversed-phase liquid chromatography-mass spectrometry (RPLC-MS) in the second dimension simultaneously allows to assess mAb titer and critical structural aspects such as aggregation, fragmentation, charge heterogeneity, molecular weight (MW), amino acid sequence and glycosylation. Complementing the LC-LC measurements at intact protein level with LC×LC based peptide mapping provides the necessary information to make clear decisions on which clones to take further into development. Copyright © 2017 Elsevier B.V. All rights reserved.
Swearingen, Kristian E.; Moritz, Robert L.
2013-01-01
SUMMARY High field asymmetric waveform ion mobility spectrometry (FAIMS) is an atmospheric pressure ion mobility technique that separates gas-phase ions by their behavior in strong and weak electric fields. FAIMS is easily interfaced with electrospray ionization and has been implemented as an additional separation mode between liquid chromatography (LC) and mass spectrometry (MS) in proteomic studies. FAIMS separation is orthogonal to both LC and MS and is used as a means of on-line fractionation to improve detection of peptides in complex samples. FAIMS improves dynamic range and concomitantly the detection limits of ions by filtering out chemical noise. FAIMS can also be used to remove interfering ion species and to select peptide charge states optimal for identification by tandem MS. Here, we review recent developments in LC-FAIMS-MS and its application to MS-based proteomics. PMID:23194268
Xie, Fuwei; Yu, Jingjing; Wang, Sheng; Zhao, Ge; Xia, Qiaoling; Zhang, Xiaobing; Zhang, Shusheng
2013-10-15
Ten primary aromatic amines (AAs) in mainstream cigarette smoke under both ISO and "Health Canada intensive" machine smoking regimens were determined in this work, which were suspected to be carcinogenic compounds. The measured AAs included aniline, ortho-toluidine, meta-toluidine, para-toluidine, 1-naphthylamine, 2-naphthylamine, 3-aminobiphenyl, 4-aminobiphenyl, meta-phenylenediamine and meta-anisidine. For rapidly and sensitively analyzing these AAs, a liquid chromatography-electrospray ionization tandem mass spectrometric (LC-MS/MS) method coupled with solid phase extraction (SPE) was developed. The particulate phase of mainstream cigarette smoke was collected on a Cambridge filter pads, while the gas phase was trapped by 25 mL 5% HCl solution. Then, the pad was extracted in an ultrasonic bath with the impinger HCl solution. After being neutralized with NaOH, the extract was purified with a HLB solid phase extraction column, and then was analyzed with LC-MS/MS using isotope-labeled internal standard. The overall sample pretreatment and analysis time was less than 1.5h. The limits of detection for all targets ranged from 0.05 ng cig(-1) to 0.96 ng cig(-1) with the recoveries in the range of 75.0-131.8%. And the intra-day and inter-day precisions were less than 10% and 16%, respectively. Under HCI machine smoking regimen, the AAs yields in mainstream cigarette smoke were much higher and the average increases were greater than 100% compared with those under ISO smoking condition. Copyright © 2013 Elsevier B.V. All rights reserved.
Hernández, Félix; Ibáñez, María; Botero-Coy, Ana-María; Bade, Richard; Bustos-López, Martha Cristina; Rincón, Javier; Moncayo, Alejandro; Bijlsma, Lubertus
2015-08-01
A large screening of around 1,000 emerging contaminants, focused on licit and illicit drugs and their metabolites, has been made in urban wastewaters (both influent and effluent) and surface waters from the area of Bogotá, Colombia. After a simple generic solid-phase extraction (SPE) step with Oasis hydrophilic-lipophilic balanced (HLB) cartridges, analyses were made by ultra high-performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS) under MS(E) mode (sequential acquisition of mass spectra at low energy (LE) and high collision energy (HE)). Accurate mass measurements and the information provided by MS(E) on the presence of the (de)protonated molecule and fragment ions allowed the reliable identification of the compounds detected, even without reference standards being available in some cases (tentative identification). The compounds most frequently found were acetaminophen/paracetamol, carbamazepine and its dihydro-dihydroxylated metabolite, clarithromycin, diclofenac, ibuprofen, gemfibrozil, lincomycin, losartan, valsartan, the two metabolites of metamizole (4-acetamido-antipyrine and 4-formylamino-antipyrine), sucralose, and cocaine and its main metabolite benzoylecgonine. Caffeine, the sweetener saccharin, and two hydroxylated metabolites of losartan were tentatively identified in almost all samples analyzed. Pharmaceutical lidocaine was tentatively identified and subsequently confirmed with reference standard. For the first time, a general overview of the occurrence of drugs and their metabolites in the aquatic environment of Colombia has been reported. In the near future, target methodologies, typically based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), will need to be set up for accurate and sensitive quantification of the contaminants selected on the basis on the information provided in the present paper.
De Zan, M M; Gil García, M D; Culzoni, M J; Siano, R G; Goicoechea, H C; Martínez Galera, M
2008-02-01
The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (MCR-ALS) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C18 150 mm x 4.6mm (5 microm particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r2 = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers. MCR-ALS was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse.
Ramsey, Edward D; Li, Ben; Guo, Wei; Liu, Jing Y
2015-04-03
An interface has been developed that connects a supercritical fluid reaction (SFR) vessel directly on-line to a liquid chromatograph. The combined SFR-LC system has enabled the progress of the esterification reaction between phenol and benzoyl chloride to synthesize phenyl benzoate in supercritical fluid carbon dioxide solution to be dynamically monitored. This was achieved by the periodic SFR-LC analysis of samples directly withdrawn from the esterification reaction mixture. Using the series of SFR-LC analysis results obtained for individual esterification reactions, the reaction progress profile for each esterification reaction was obtained by expressing the measured yield of phenyl benzoate as a function of reaction time. With reaction temperature fixed at 75°C, four sets (n=3) of SFR-LC reaction progress profiles were obtained at four different SFR pressures ranging from 13.79 to 27.58 MPa. The maximum SFR yield obtained for phenyl benzoate using a standard set of reactant concentrations was 85.2% (R.S.D. 4.2%) when the reaction was performed at 13.79 MPa for 90 min. In comparison, a phenyl benzoate yield of less than 0.3% was obtained using the same standard reactant concentrations after 90 min reaction time at 75°C using either: heptane, ethyl acetate or acetonitrile as conventional organic reaction solvents. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Martono, Y.; Rohman, A.; Riyanto, S.; Martono, S.
2018-04-01
Solid Phase Extraction (SPE) method using silica as sorbent for stevioside and rebaudiosida A analysis in Stevia rebaudiana Bertoni leaf have not been performed. The aim of this study is to develop SPE method using silica as sorbent for Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) analysis of stevioside and rebaudiosida A in S. rebaudiana leaf. The results of this study indicate that the optimal conditions for normal phase SPE (silica) are conditioned with 3.0 mL of hexane. The sample loading volume is 0.1 mL. Cartridge is eluted with 1.0 mL acetonitrile: water (80: 20, v/v) to separate both analytes. The cartridge is washed with chloroform and water of 0.3 mL respectively. The developed SPE sample preparation method meets the accuracy and precision test and can be used for the analysis of stevioside and rebaudioside A by RP-HPLC.
Inoue, Koichi; Yoshie, Yuriko; Kondo, Sachiko; Yoshimura, Yoshihiro; Nakazawa, Hiroyuki
2002-02-08
A sensitive method for the simultaneous determination of phenolic xenoestrogens such as bisphenol A, 2,4-dichlorophenol, 4-tert,-butylphenol, 4-n2-pentylphenol, 4-n-hexylphenol, 4-n-heptylphenol, 4-octylphenol, 4-nonylphenol was developed using reversed-phase LC and coulometric-array detection. Stepwise gradient elution with phosphoric acid in water-acetonitrile was used. The calibration curves were linear in the range of 5.0 (or 10.0)-1000 ng ml(-1) with correlation coefficients of 0.9978-0.9999, the limits of detection were 0.01-0.02 ng ml(-1). Sample clean-up was performed by solid-phase extraction (SPE) using 3M Empore extraction disks. Three commercial sorbents, C18, SDB-XD (styrene-divinylbenzene polymer) and SDB-RPS (sulfonated styrene-divinylbenzene polymer) were compared. The highest recoveries were obtained with SDB-RPS. They were above 70% with a relative standard deviation of less than 15%. The proposed method was applied to the determination of phenolic xenoestrogens in various water samples.
Jiang, Jheng-Jie; Lee, Chon-Lin; Fang, Meng-Der
2014-08-30
This study provides a first estimate of the sources, distribution, and risk presented by emerging organic contaminants (EOCs) in coastal waters off southwestern Taiwan. Ten illicit drugs, seven nonsteroidal anti-inflammatory drugs (NSAIDs), five antibiotics, two blood lipid regulators, two antiepileptic drugs, two UV filters, caffeine, atenolol, and omeprazole were analyzed by solid-phase extraction and liquid chromatography coupled to tandem mass spectrometry (SPE-LC-MS/MS). Thirteen EOCs were detected in coastal waters, including four NSAIDs (acetaminophen, ibuprofen, ketoprofen, and codeine), three antibiotics (ampicillin, erythromycin, and cefalexin), three illicit drugs (ketamine, pseudoephedrine, and MDMA), caffeine, carbamazepine, and gemfibrozil. The median concentrations for the 13 EOCs ranged from 1.47 ng/L to 156 ng/L. Spatial variation in concentration of the 13 EOCs suggests discharge into coastal waters via ocean outfall pipes and rivers. Codeine and ampicillin have significant pollution risk quotients (RQ>1), indicating potentially high risk to aquatic organisms in coastal waters. Copyright © 2013 Elsevier Ltd. All rights reserved.
A generic method for the determination of acrylamide in thermally processed foods.
Gökmen, Vural; Senyuva, Hamide Z
2006-07-07
A generic sample preparation method for the determination of acrylamide in foods was developed. The method entails extraction with methanol, purification with Carrez I and II solutions, evaporation and solvent change to water, and cleanup with Oasis HLB solid-phase extraction (SPE) cartridge. The final extract was analyzed by liquid chromatography-mass spectrometry (LC-MS) for quantitation. The chromatographic separation was performed on ODS-3 column using the isocratic mixture of 0.01 mM acetic acid in 0.2% aqueous solution of formic acid at a flow rate of 0.6 ml/min at 25 degrees C. The recoveries of acrylamide from potato chips, biscuits and coffee ranged between 92.8 and 101.5% with relative standard deviations of 4.1% or less. The limit of detection (LOD) and the limit of quantitation (LOQ) were 2 ng/g and 6 ng/g in the basis of signal to noise ratios of 3:1 and 9:1, respectively.
NASA Astrophysics Data System (ADS)
González, Susana; Petrovic, Mira; Barceló, Damiá
2008-07-01
SummaryThe removal of selected surfactants, linear alkylbenzene sulfonates (LAS), coconut diethanol amides (CDEA) and alkylphenol ethoxylates and their degradation products were investigated using a two membrane bioreactor (MBR) with hollow fiber and plate and frame membranes. The two pilot plants MBR run in parallel to a full-scale conventional activated sludge (CAS) treatment. A total of eight influent samples with the corresponding effluent samples were analysed by solid phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS). The results indicate that both MBR have a better effluent quality in terms of chemical and biological oxygen demand (COD and BOD), NH4+ , concentration and total suspended solids (TSS). MBR showed a better similar performance in the overall elimination of the total nonylphenolic compounds, achieving a 75% of elimination or a 65% (the same elimination reached by CAS). LAS and CDEA showed similar elimination in the three systems investigated and no significant differences were observed.
Aqueous photodegradation of antibiotic florfenicol: kinetics and degradation pathway studies.
Zhang, Ya; Li, Jianhua; Zhou, Lei; Wang, Guoqing; Feng, Yanhong; Wang, Zunyao; Yang, Xi
2016-04-01
The occurrence of antibacterial agents in natural environment was of scientific concern in recent years. As endocrine disrupting chemicals, they had potential risk on ecology system and human beings. In the present study, the photodegradation kinetics and pathways of florfenicol were investigated under solar and xenon lamp irradiation in aquatic systems. Direct photolysis half-lives of florfenicol were determined as 187.29 h under solar irradiation and 22.43 h under xenon lamp irradiation, respectively. Reactive oxygen species (ROS), such as hydroxyl radical (·OH) and singlet oxygen ((1)O2) were found to play an important role in indirect photolysis process. The presence of nitrate and dissolved organic matters (DOMs) could affect photolysis of florfenicol in solutions through light screening effect, quenching effect, and photoinduced oxidization process. Photoproducts of florfenicol in DOMs solutions were identified by solid phase extraction-liquid chromatography-mass spectrometry (SPE-LC-MS) analysis techniques, and degradation pathways were proposed, including photoinduced hydrolysis, oxidation by (1)O2 and ·OH, dechlorination, and cleavage of the side chain.
OASIS: Organics Analyzer for Sampling Icy Surfaces
NASA Technical Reports Server (NTRS)
Getty, S. A.; Dworkin, J. P.; Glavin, D. P.; Martin, M.; Zheng, Y.; Balvin, M.; Southard, A. E.; Ferrance, J.; Malespin, C.
2012-01-01
Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.
Kobayashi, Takeshi; Kobayashi, Yo; Tabuchi, Masato; Shono, Kumi; Ohno, Yasutaka; Mita, Yuichi; Miyashiro, Hajime
2013-12-11
The all solid-state lithium battery with polyether-based solid polymer electrolyte (SPE) is regarded as one of next-generation lithium batteries, and has potential for sufficient safety because of the flammable-electrolyte-free system. It has been believed that polyether-based SPE is oxidized at the polymer/electrode interface with 4 V class cathodes. Therefore, it has been used for electric devices such as organic transistor, and lithium battery under 3 V. We estimated decomposition reaction of polyether used as SPE of all solid-state lithium battery. We first identified the decomposed parts of polyether-based SPE and the conservation of most main chain framework, considering the results of SPE analysis after long cycle operations. The oxidation reaction was found to occur slightly at the ether bond in the main chain with the branched side chain. Moreover, we resolved the issue by introducing a self-sacrificing buffer layer at the interface. The introduction of sodium carboxymethyl cellulose (CMC) to the 4 V class cathode surface led to the suppression of SPE decomposition at the interface as a result of the preformation of a buffer layer from CMC, which was confirmed by the irreversible exothermic reaction during the first charge, using electrochemical calorimetry. The attained 1500 cycle operation is 1 order of magnitude longer than those of previously reported polymer systems, and compatible with those of reported commercial liquid systems. The above results indicate to proceed to an intensive research toward the realization of 4 V class "safe" lithium polymer batteries without flammable liquid electrolyte.
Cimetiere, Nicolas; Soutrel, Isabelle; Lemasle, Marguerite; Laplanche, Alain; Crocq, André
2013-01-01
The study of the occurrence and fate of pharmaceutical compounds in drinking or waste water processes has become very popular in recent years. Liquid chromatography with tandem mass spectrometry is a powerful analytical tool often used to determine pharmaceutical residues at trace level in water. However, many steps may disrupt the analytical procedure and bias the results. A list of 27 environmentally relevant molecules, including various therapeutic classes and (cardiovascular, veterinary and human antibiotics, neuroleptics, non-steroidal anti-inflammatory drugs, hormones and other miscellaneous pharmaceutical compounds), was selected. In this work, a method was developed using ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) and solid-phase extraction to determine the concentration of the 27 targeted pharmaceutical compounds at the nanogram per litre level. The matrix effect was evaluated from water sampled at different treatment stages. Conventional methods with external calibration and internal standard correction were compared with the standard addition method (SAM). An accurate determination of pharmaceutical compounds in drinking water was obtained by the SAM associated with UPLC-MS/MS. The developed method was used to evaluate the occurrence and fate of pharmaceutical compounds in some drinking water treatment plants in the west of France.
Cai, Meiqiang; Chen, Xiaohong; Wei, Xiaoqing; Pan, Shengdong; Zhao, Yonggang; Jin, Micong
2014-09-01
A rapid and accurate method by liquid chromatography/tandem mass spectrometry (LC-MS/MS) using positive electrospray was established for the determination of ricinine in cooking oils. The homogenized samples, spiked with (13)C6-labelled ricinine as an internal standard, were extracted using ethanol/water (20:80, v/v) and purified by dispersive solid-phase extraction (dSPE) using primary-secondary amine (PSA) and C18 as adsorbents. The extract was separated in a short C18 reversed-phase column using methanol/water (25:75, v/v) as the mobile phase and detected in multiple reaction monitoring (MRM) mode with the absolute matrix effect of 93.2-102.2%. The alkali-metal adduct ions were discussed and the mass/mass fragmentation pathway was explained. Ricinine showed good linearity in the range of 0.5-50.0 μg/kg with the limit of quantitation 0.5 μg/kg. The recoveries were between 86.0% and 98.3% with the intra- and inter-day RSDs of 2.6-7.0%, 5.5-10.8%, respectively. This method could be applied to the rapid quantification of ricinine in cooking oils. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue
2016-03-01
A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lerch, Oliver; Temme, Oliver; Daldrup, Thomas
2014-07-01
The analysis of opioids, cocaine, and metabolites from blood serum is a routine task in forensic laboratories. Commonly, the employed methods include many manual or partly automated steps like protein precipitation, dilution, solid phase extraction, evaporation, and derivatization preceding a gas chromatography (GC)/mass spectrometry (MS) or liquid chromatography (LC)/MS analysis. In this study, a comprehensively automated method was developed from a validated, partly automated routine method. This was possible by replicating method parameters on the automated system. Only marginal optimization of parameters was necessary. The automation relying on an x-y-z robot after manual protein precipitation includes the solid phase extraction, evaporation of the eluate, derivatization (silylation with N-methyl-N-trimethylsilyltrifluoroacetamide, MSTFA), and injection into a GC/MS. A quantitative analysis of almost 170 authentic serum samples and more than 50 authentic samples of other matrices like urine, different tissues, and heart blood on cocaine, benzoylecgonine, methadone, morphine, codeine, 6-monoacetylmorphine, dihydrocodeine, and 7-aminoflunitrazepam was conducted with both methods proving that the analytical results are equivalent even near the limits of quantification (low ng/ml range). To our best knowledge, this application is the first one reported in the literature employing this sample preparation system.
Pan, Xun; Qiang, Zhimin; Ben, Weiwei; Chen, Meixue
2011-01-01
This work describes a systematic approach to the development of a method for simultaneous determination of three classes of veterinary antibiotics in the suspended solids (SS) of swine wastewater, including five sulfonamides, three tetracyclines and one macrolide (tiamulin). The entire procedures for sample pretreatment, ultrasonic extraction (USE), solid-phase extraction (SPE), and liquid chromatography-mass spectrometry (LC-MS) quantification were examined and optimized. The recovery efficiencies were found to be 76%-104% for sulfonamides, 81%-112% for tetracyclines, and 51%-64% for tiamulin at three spiking levels. The intra-day and inter-day precisions, as expressed by the relative standard deviation (RSD), were below 17%. The method detection limits (MDLs) were between 0.14 and 7.14 microg/kg, depending on a specific antibiotic studied. The developed method was applied to field samples collected from three concentrated swine feeding plants located in Beijing, Shanghai and Shandong province of China. All the investigated antibiotics were detected in both SS and liquid phase of swine wastewater, with partition coefficients (logK(d)) ranging from 0.49 to 2.30. This study demonstrates that the SS can not be ignored when determining the concentrations of antibiotics in swine wastewater.
Fankhauser-Noti, Anja; Fiselier, Katell; Biedermann-Brem, Sandra; Grob, Koni
2005-08-05
The migration of epoxidized soy bean oil (ESBO) from the gasket in the lids of glass jars into foods, particularly those rich in edible oil, often far exceeds the legal limit (60 mg/kg). ESBO was determined through a methyl ester isomer of diepoxy linoleic acid. Transesterification occurred directly in the homogenized food. From the extracted methyl esters, the diepoxy components were isolated by normal-phase LC and transferred on-line to gas chromatography with flame ionization detection using the on-column interface in the concurrent solvent evaporation mode. The method involves verification elements to ensure the reliability of the results for every sample analyzed. The detection limit is 2-5 mg/kg, depending on the food. Uncertainty of the procedure is below 10%.
Aga, D.S.; Thurman, E.M.; Pomes, M.L.
1994-01-01
Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were combined for the trace analysis of the herbicide alachlor and its major soil metabolite, ethanesulfonic acid (ESA). The anti-alachlor antibody cross-reacted with ESA, which produced false-positive detections of alachlor in water samples by immunoassay screens. Alachlor and ESA were isolated from water by SPE on a C18 resin and eluted sequentially with ethyl acetate and methanol. Alachlor is soluble in ethyl acetate while the anionic ESA is not. Thus ESA remained adsorbed on the C18 resin and was eluted later with methanol. The combination of SPE with ELISA effectivety separated and quantified both alachlor and ESA using the same antibody for two ELISA methods. The general method may have applicability for the separation of other herbicides and their ionic metabolites. The SPE-ELISA method has a, detection limit of 0.01 ??g/L for alachlor and 0.05 ??g/L for ESA, with a precision of ?? 10%. Analyses of surface and ground water samples were confirmed by gas chromatography/mass spectrometry and high-performance liquid chromatography with photodiode-array detection. Results showed widespread occurrence of ESA in surface and ground water of the midwestern United States, with concentrations ranging from 10 ??g/L.
Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.
Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H
2016-12-01
In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.
Cheng, Wing-Chi; Yau, Tsan-Sang; Wong, Ming-Kei; Chan, Lai-Ping; Mok, Vincent King-Kuen
2006-10-16
A rapid urinalysis system based on SPE-LC-MS/MS with an in-house post-analysis data management system has been developed for the simultaneous identification and semi-quantitation of opiates (morphine, codeine), methadone, amphetamines (amphetamine, methylamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)), 11-benzodiazepines or their metabolites and ketamine. The urine samples are subjected to automated solid phase extraction prior to analysis by LC-MS (Finnigan Surveyor LC connected to a Finnigan LCQ Advantage) fitted with an Alltech Rocket Platinum EPS C-18 column. With a single point calibration at the cut-off concentration for each analyte, simultaneous identification and semi-quantitation for the above mentioned drugs can be achieved in a 10 min run per urine sample. A computer macro-program package was developed to automatically retrieve appropriate data from the analytical data files, compare results with preset values (such as cut-off concentrations, MS matching scores) of each drug being analyzed and generate user-defined Excel reports to indicate all positive and negative results in batch-wise manner for ease of checking. The final analytical results are automatically copied into an Access database for report generation purposes. Through the use of automation in sample preparation, simultaneous identification and semi-quantitation by LC-MS/MS and a tailored made post-analysis data management system, this new urinalysis system significantly improves the quality of results, reduces the post-data treatment time, error due to data transfer and is suitable for high-throughput laboratory in batch-wise operation.
Antioxidative properties of defatted dabai pulp and peel prepared by solid phase extraction.
Khoo, Hock Eng; Azlan, Azrina; Ismail, Amin; Abas, Faridah
2012-08-14
Solid phase extraction (SPE) using Sep-Pak® cartridges is one of the techniques used for fractionation of antioxidant compounds in waste of dabai oil extraction (defatted dabai parts). The aim of this study was to determine the phenolic compounds and antioxidant capacity in crude extracts and several SPE fractions from methanolic extract of defatted dabai pulp and peel. Based on SPE, Sep-Pak® cyanopropyl and C₁₈ cartridges were used to fractionate the antioxidant-rich crude extracts into water and methanolic fractions. Analyzed using LC-MS, flavonoids, anthocyanins, saponin derivatives and other unknown antioxidative compounds were detected in the defatted dabai crude extracts and their SPE fractions. Anthocyanins were the major phenolic compounds identified in the defatted dabai peel and detected in most of the SPE fractions. Methanolic fractions of defatted dabai parts embraced higher total phenolics and antioxidant capacity than water fractions. This finding also revealed the crude extracts of defatted dabai peel have the most significant antioxidant properties compared to the methanolic and water fractions studied. The crude extract of defatted dabai parts remain as the most potent antioxidant as it contains mixture of flavonoids, anthocyanins and other potential antioxidants.
Abbatiello, Susan E; Mani, D R; Schilling, Birgit; Maclean, Brendan; Zimmerman, Lisa J; Feng, Xingdong; Cusack, Michael P; Sedransk, Nell; Hall, Steven C; Addona, Terri; Allen, Simon; Dodder, Nathan G; Ghosh, Mousumi; Held, Jason M; Hedrick, Victoria; Inerowicz, H Dorota; Jackson, Angela; Keshishian, Hasmik; Kim, Jong Won; Lyssand, John S; Riley, C Paige; Rudnick, Paul; Sadowski, Pawel; Shaddox, Kent; Smith, Derek; Tomazela, Daniela; Wahlander, Asa; Waldemarson, Sofia; Whitwell, Corbin A; You, Jinsam; Zhang, Shucha; Kinsinger, Christopher R; Mesri, Mehdi; Rodriguez, Henry; Borchers, Christoph H; Buck, Charles; Fisher, Susan J; Gibson, Bradford W; Liebler, Daniel; Maccoss, Michael; Neubert, Thomas A; Paulovich, Amanda; Regnier, Fred; Skates, Steven J; Tempst, Paul; Wang, Mu; Carr, Steven A
2013-09-01
Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.
Abbatiello, Susan E.; Mani, D. R.; Schilling, Birgit; MacLean, Brendan; Zimmerman, Lisa J.; Feng, Xingdong; Cusack, Michael P.; Sedransk, Nell; Hall, Steven C.; Addona, Terri; Allen, Simon; Dodder, Nathan G.; Ghosh, Mousumi; Held, Jason M.; Hedrick, Victoria; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kim, Jong Won; Lyssand, John S.; Riley, C. Paige; Rudnick, Paul; Sadowski, Pawel; Shaddox, Kent; Smith, Derek; Tomazela, Daniela; Wahlander, Asa; Waldemarson, Sofia; Whitwell, Corbin A.; You, Jinsam; Zhang, Shucha; Kinsinger, Christopher R.; Mesri, Mehdi; Rodriguez, Henry; Borchers, Christoph H.; Buck, Charles; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel; MacCoss, Michael; Neubert, Thomas A.; Paulovich, Amanda; Regnier, Fred; Skates, Steven J.; Tempst, Paul; Wang, Mu; Carr, Steven A.
2013-01-01
Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities. PMID:23689285
Marshall, Peter S; Leavens, Bill; Heudi, Olivier; Ramirez-Molina, Cesar
2004-11-12
Both LC and capillary LC (CapLC) have been successfully interfaced with inductively coupled plasma mass spectrometry (ICP-MS). Gradients of acetonitrile and aqueous based solvents have been employed to separate several compounds of pharmaceutical interest. This paper will describe four application areas in the pharmaceutical industry, and examples will be shown where CapLC, LC and gel electrophoresis via laser ablation have been coupled with ICP-MS. The four areas highlighted in this paper are: (1) the use of derivatisation reactions to "make the invisible visible". Methods involving derivatisations with copper and iron will be described that can be used for the analysis of amines and carboxylic acids by ICP-MS. (2) The profiling of metal ion content (in particular bromine) in biological samples such as human plasma, this study will focus on the metabolism of bromine-labelled peptides (e.g. substance P). (3) The analysis of materials derived from single, solid-phase beads used in combinatorial chemistry, and (4) also discussed will be our findings from investigations into the use of laser ablation ICP-MS on the determination of protein phosphorylation on electrophoresis gel blots.
Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd
2016-03-25
Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. Copyright © 2015 Elsevier B.V. All rights reserved.
von Guggenberg, Elisabeth; Penz, Barbara; Kemmler, Georg; Virgolini, Irene; Decristoforo, Clemens
2006-02-01
[99mTc-EDDA-HYNIC-D-Phe1,Tyr3]-octreotide (99mTc-EDDA-HYNIC-TOC) is an alternative radioligand for somatostatin receptor (SSTR) scintigraphy of neuroendocrine tumours. In order to allow a rapid and accurate determination of the quality in the clinical routine the aim of this study was to evaluate different methods of radiochemical purity (RCP) testing. Three different methods of RCP testing were compared: high-performance liquid chromatography (HPLC), thin layer chromatography (TLC) and minicolumn (Sep-Pak purification = SPE). HPLC was shown to be the most effective method for the quality control. The use of TLC and SPE is only recommended after sufficient practical labelling experience.
2013-01-01
Background Sucralose has gained popularity as a low calorie artificial sweetener worldwide. Due to its high stability and persistence, sucralose has shown widespread occurrence in environmental waters, at concentrations that could reach up to several μg/L. Previous studies have used time consuming sample preparation methods (offline solid phase extraction/derivatization) or methods with rather high detection limits (direct injection) for sucralose analysis. This study described a faster and sensitive analytical method for the determination of sucralose in environmental samples. Results An online SPE-LC–MS/MS method was developed, being capable to quantify sucralose in 12 minutes using only 10 mL of sample, with method detection limits (MDLs) of 4.5 ng/L, 8.5 ng/L and 45 ng/L for deionized water, drinking and reclaimed waters (1:10 diluted with deionized water), respectively. Sucralose was detected in 82% of the reclaimed water samples at concentrations reaching up to 18 μg/L. The monthly average for a period of one year was 9.1 ± 2.9 μg/L. The calculated mass loads per capita of sucralose discharged through WWTP effluents based on the concentrations detected in wastewaters in the U. S. is 5.0 mg/day/person. As expected, the concentrations observed in drinking water were much lower but still relevant reaching as high as 465 ng/L. In order to evaluate the stability of sucralose, photodegradation experiments were performed in natural waters. Significant photodegradation of sucralose was observed only in freshwater at 254 nm. Minimal degradation (<20%) was observed for all matrices under more natural conditions (350 nm or solar simulator). The only photolysis product of sucralose identified by high resolution mass spectrometry was a de-chlorinated molecule at m/z 362.0535, with molecular formula C12H20Cl2O8. Conclusions Online SPE LC-APCI/MS/MS developed in the study was applied to more than 100 environmental samples. Sucralose was frequently detected (>80%) indicating that the conventional treatment process employed in the sewage treatment plants is not efficient for its removal. Detection of sucralose in drinking waters suggests potential contamination of surface and ground waters sources with anthropogenic wastewater streams. Its high resistance to photodegradation, minimal sorption and high solubility indicate that sucralose could be a good tracer of anthropogenic wastewater intrusion into the environment. PMID:23965251
McDonald, Mark; Malone, Edward; McBride, John
2010-01-01
A novel and rapid method was developed and validated for the confirmation of endogenous and synthetic hormones in animal serum using LC/MS/MS. Detection of 17 beta-estradiol and beta-testosterone below the respective European Union-recommended levels of 0.1 and 0.5 microg/L was achieved, as was a required performance level of 0.1 microg/L for 17 alpha-estradiol and 0.5 microg/L for 17 alpha-testosterone, medroxyprogesterone-17-acetate, and progesterone. The method was established with dilution of serum followed by ion-exchange SPE, LC separation and MS detection with electrospray ionization, selected reaction monitoring, and positivelnegative switching. Two characteristic transitions were monitored for each analyte. The method was applied to bovine, ovine, porcine, equine, and avian samples and validated according to European Commission Decision 2002/657/EC and accepted for ISO/IEC 17025:2005 accreditation. An extended calibration curve allows naturally occurring levels of endogenous hormones to be quantified. Recoveries ranged from 97.3% for 17 alpha-testosterone to 102.0% for 17 alpha-estradiol. The decision limit CCalpha ranged from 0.02 microg/L for 17 alpha- and beta-estradiol to 0.12 microg/L for progesterone. Detection capability CCbeta ranged from 0.03 microg/L for 17 a-estradiol to 0.20 microg/L for progesterone.
Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.
NASA Astrophysics Data System (ADS)
Gilevska, Tetyana; Gehre, Matthias; Richnow, Hans
2014-05-01
Compound Specific Isotope Analysis (CSIA) has been an important step for the assessment of the origin and fate of compounds in environmental science.[1] Biologically or pharmaceutically important compounds often are not amenable for gas chromatographic separation because of high polarity and lacking volatility, thermostability. In 2004 liquid chromatography isotope ratio mass spectrometry (LC-IRMS) became commercially available. LC-IRMS system intent a quantitative conversion of analytes separation into CO2 via wet oxidation with sodium persulfate in the presence of phosphoric acid while analytes are still dissolved in the aqueous liquid phase.[2] The aim of this study is to analyze the oxidation capacity of the interface of the LC-IRMS system and determine which parameters could improve oxidation of compounds which are resistant to persulfate oxidation. Oxidation capacity of the liquid chromatography isotope ratio mass spectrometry system was tested with halogenated acetic acid and a set of aromatic compounds with different substitutes. Acetic acid (AA) was taken as a model compound for complete oxidation and compared to the oxidation of other analytes on a molar basis. Correct values were obtained for di- and mono chlorinated and fluorinated and also for tribrominated acetic acid and for all studied aromatic compounds. Incomplete oxidation for trichloroacetic (TCAA) and trifluoroacetic (TFAA) acid was revealed with lower recovery compared to acetic acid and isotope fractionation leading to depleted carbon isotope composition compared to values obtained with an elementary analyzer connected to an isotope mass spectrometer Several optimization steps were tried in order to improve the oxidation of TCAA and TFAA: (i) increasing the concentration of the oxidizing agent, (ii) variation of flow rate of the oxidizing and acid solution, (iii) variation of flow rate of liquid chromatography pump (iv) addition of a catalyzer. These modifications lead to longer reaction time in the coil and increase in the concentration of radical but complete combustion of highly chlorinated or fluorinated compounds was not achieved. Due to these findings the limit for a LC-IRMS system for similar structure compounds can be predicted. 1. Elsner, M., et al., Current challenges in compound-specific stable isotope analysis of environmental organic contaminants. Analytical and Bioanalytical Chemistry, 2012. 403(9): p. 2471-2491. 2. Krummen, M., et al., A new concept for isotope ratio monitoring liquid chromatography/mass spectrometry. Rapid Communications in Mass Spectrometry, 2004. 18(19): p. 2260-2266.
Miniaturized protein separation using a liquid chromatography column on a flexible substrate
NASA Astrophysics Data System (ADS)
Yang, Yongmo; Chae, Junseok
2008-12-01
We report a prototype protein separator that successfully miniaturizes existing technology for potential use in biocompatible health monitoring implants. The prototype is a liquid chromatography (LC) column (LC mini-column) fabricated on an inexpensive, flexible, biocompatible polydimethylsiloxane (PDMS) enclosure. The LC mini-column separates a mixture of proteins using size exclusion chromatography (SEC) with polydivinylbenzene beads (5-20 µm in diameter with 10 nm pore size). The LC mini-column is smaller than any commercially available LC column by a factor of ~11 000 and successfully separates denatured and native protein mixtures at ~71 psi of the applied fluidic pressure. Separated proteins are analyzed using NuPAGE-gel electrophoresis, high-performance liquid chromatography (HPLC) and an automated electrophoresis system. Quantitative HPLC results demonstrate successful separation based on intensity change: within 12 min, the intensity between large and small protein peaks changed by a factor of ~20. In further evaluation using the automated electrophoresis system, the plate height of the LC mini-column is between 36 µm and 100 µm. The prototype LC mini-column shows the potential for real-time health monitoring in applications that require inexpensive, flexible implant technology that can function effectively under non-laboratory conditions.
Chang, Shaojie; Song, Xiaomin; Yan, Ming; Zhou, Zhaocai; Wu, Fang; Gong, Weimin
2004-01-01
The proteins Spe31 and Spe32, named after their respective molecular weights of about 31 and 32 kDa, were purified simultaneously from the seeds of Pachyrrhizus erosus. They cannot be separated from each other by column chromatography. N-terminal sequence analysis indicated that they belonged to the papain family of cysteine proteases. An in-gel activity assay revealed that Spe31 possesses proteolytic activity while Spe32 only displays very weak activity for protein degradation. Both of them are glycoproteins as detected by the periodic acid and Schiff's reagent method. Crystals were obtained from the protein mixture by the hanging-drop vapour-diffusion method; they diffracted to a resolution of 2.61 A on an in-house X-ray source. The crystals belong to space group P4(1(3))2(1)2, with unit-cell parameters a = b = 61.96, c = 145.61 A. Gel electrophoresis under non-denaturing conditions showed that the protein crystallized was Spe31.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, T.F.; Thorne, P.G.; Myers, K.F.
Salting-out solvent extraction (SOE) was compared with cartridge and membrane solid-phase extraction (SPE) for preconcentration of nitroaromatics, nitramines, and aminonitroaromatics prior to determination by reversed-phase high-performance liquid chromatography. The solid phases used were manufacturer-cleaned materials, Porapak RDX for the cartridge method and Empore SDB-RPS for the membrane method. Thirty-three groundwater samples from the Naval Surface Warfare Center, Crane, Indiana, were analyzed using the direct analysis protocol specified in SW846 Method 8330, and the results were compared with analyses conducted after preconcentration using SOE with acetonitrile, cartridge-based SPE, and membrane-based SPE. For high-concentration samples, analytical results from the three preconcentration techniquesmore » were compared with results from the direct analysis protocol; good recovery of all target analytes was achieved by all three pre-concentration methods. For low-concentration samples, results from the two SPE methods were correlated with results from the SOE method; very similar data was obtained by the SOE and SPE methods, even at concentrations well below 1 microgram/L.« less
Yahaya, Noorfatimah; Sanagi, Mohd Marsin; Abd Aziz, Noorizan; Wan Ibrahim, Wan Aini; Nur, Hadi; Loh, Saw Hong; Kamaruzaman, Sazlinda
2017-02-01
A rapid dispersive micro-solid phase extraction (D-μ-SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM-41 was used as sorbent in d-μ-SPE of the azole compounds from biological fluids. Important D-μ-SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB-C 18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile-0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v/v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1-10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra- and inter-day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3-114.8%. The MCM-41-D-μ-SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis. Copyright © 2016 John Wiley & Sons, Ltd.
Krupadam, Reddithota J; Bhagat, Bhagyashree; Khan, Muntazir S
2010-08-01
A method based on solid--phase extraction with a molecularly imprinted polymer (MIP) has been developed to determine five probable human carcinogenic polycyclic aromatic hydrocarbons (PAHs) in ambient air dust by gas chromatography-mass spectrometry (GC-MS). Molecularly imprinted poly(vinylpyridine-co-ethylene glycol dimethacrylate) was chosen as solid-phase extraction (SPE) material for PAHs. The conditions affecting extraction efficiency, for example surface properties, concentration of PAHs, and equilibration times were evaluated and optimized. Under optimum conditions, pre-concentration factors for MIP-SPE ranged between 80 and 93 for 10 mL ambient air dust leachate. PAHs recoveries from MIP-SPE after extraction from air dust were between 85% and 97% and calibration graphs of the PAHs showed a good linearity between 10 and 1000 ng L(-1) (r = 0.99). The extraction efficiency of MIP for PAHs was compared with that of commercially available SPE materials--powdered activated carbon (PAC) and polystyrene-divinylbenzene resin (XAD)--and it was shown that the extraction capacity of the MIP was better than that of the other two SPE materials. Organic matter in air dust had no effect on MIP extraction, which produced a clean extract for GC-MS analysis. The detection limit of the method proposed in this article is 0.15 ng L(-1) for benzo[a]pyrene, which is a marker molecule of air pollution. The method has been applied to the determination of probable carcinogenic PAHs in air dust of industrial zones and satisfactory results were obtained.
Liu, Lingling; Huang, Hua; Wu, Yanwen; Li, Bingning; Ouyang, Jie
2017-09-01
An offline solid-phase extraction (SPE) approach combined with a large-volume injection (LVI)-gas chromatography-flame ionization detector (LVI-GC-FID) is improved for routine analysis of mineral oil saturated hydrocarbons (MOSH) in vegetable oils. The key procedure of the method consists in using offline SPE columns for MOSH purification. The SPE column packed with 1% Ag-activated silica gel was used to separate MOSH from triglycerides and olefins in variety of vegetable oils. The eluent of MOSH fraction was only 3 mL and the concentration step was quick with little evaporation loss. The limit of quantification (LOQ) of the method was 2.5 mg/kg and the linearity ranged from 2 to 300 mg/kg. The accuracy was assessed by measuring the recoveries from spiked oil samples and was higher than 90%. Twenty-seven commercial vegetable oils were analyzed, and different levels of MOSH contamination were detected with the highest being 259.4 mg/kg. The results suggested that it is necessary to routinely detect mineral oil contamination in vegetable oils for food safety.
Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori
2011-07-01
A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Muhamad, Halimah; Zainudin, Badrul Hisyam; Abu Bakar, Nor Kartini
2012-10-15
Solid phase extraction (SPE) and dispersive solid-phase extraction (d-SPE) were compared and evaluated for the determination of λ-cyhalothrin and cypermethrin in palm oil matrices by gas chromatography with an electron capture detector (GC-ECD). Several SPE sorbents such as graphitised carbon black (GCB), primary secondary amine (PSA), C(18), silica, and florisil were tested in order to minimise fat residues. The results show that mixed sorbents using GCB and PSA obtained cleaner extracts than a single GCB and PSA sorbents. The average recoveries obtained for each pesticide ranged between 81% and 114% at five fortification levels with the relative standard deviation of less than 7% in all cases. The limits of detection for these pesticides were ranged between 0.025 and 0.05 μg/g. The proposed method was applied successfully for the residue determination of both λ-cyhalothrin and cypermethrin in crude palm oil samples obtained from local mills throughout Malaysia. Copyright © 2012 Elsevier Ltd. All rights reserved.
Wang, Xiu-Li; Zhu, Ying; Fang, Qun
2014-01-07
In this work, the combination of droplet-based microfluidics with liquid chromatography/mass spectrometry (LC/MS) was achieved, for providing a fast separation and high-information-content detection method for the analysis of nanoliter-scale droplets with complex compositions. A novel interface method was developed using an oil-covered droplet array chip to couple with an LC/MS system via a capillary sampling probe and a 4 nL injection valve without the need of a droplet extraction device. The present system can perform multistep operations including parallel enzyme inhibition reactions in nanoliter droplets, 4 nL sample injection, fast separation with capillary LC, and label-free detection with ESI-MS, and has significant flexibility in the accurate addressing and sampling of droplets of interest on demand. The system performance was evaluated using angiotensin I and angiotensin II as model samples, and the repeatabilities of peak area for angiotensin I and angiotensin II were 2.7% and 7.5% (RSD, n = 4), respectively. The present system was further applied to the screening for inhibitors of cytochrome P450 (CYP1A2) and measurement of the IC50 value of the inhibitor. The sample consumption for each droplet assay was 100 nL, which is reduced 10-100 times compared with conventional 384-multi-well plate systems usually used in high-throughput drug screening.
Liquid crystal based biosensors for bile acid detection
NASA Astrophysics Data System (ADS)
He, Sihui; Liang, Wenlang; Tanner, Colleen; Fang, Jiyu; Wu, Shin-Tson
2013-03-01
The concentration level of bile acids is a useful indicator for early diagnosis of liver diseases. The prevalent measurement method in detecting bile acids is the chromatography coupled with mass spectrometry, which is precise yet expensive. Here we present a biosensor platform based on liquid crystal (LC) films for the detection of cholic acid (CA). This platform has the advantage of low cost, label-free, solution phase detection and simple analysis. In this platform, LC film of 4-Cyano-4'-pentylbiphenyl (5CB) was hosted by a copper grid supported with a polyimide-coated glass substrate. By immersing into sodium dodecyl sulfate (SDS) solution, the LC film was coated with SDS which induced a homeotropic anchoring of 5CB. Addition of CA introduced competitive adsorption between CA and SDS at the interface, triggering a transition from homeotropic to homogeneous anchoring. The detection limit can be tuned by changing the pH value of the solution from 12uM to 170uM.
Analysis of street drugs in seized material without primary reference standards.
Laks, Suvi; Pelander, Anna; Vuori, Erkki; Ali-Tolppa, Elisa; Sippola, Erkki; Ojanperä, Ilkka
2004-12-15
A novel approach was used to analyze street drugs in seized material without primary reference standards. Identification was performed by liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS), essentially based on accurate mass determination using a target library of 735 exact monoisotopic masses. Quantification was carried out by liquid chromatography/chemiluminescence nitrogen detection (LC/CLND) with a single secondary standard (caffeine), utilizing the detector's equimolar response to nitrogen. Sample preparation comprised dilution, first with methanol and further with the LC mobile phase. Altogether 21 seized drug samples were analyzed blind by the present method, and results were compared to accredited reference methods utilizing identification by gas chromatography/mass spectrometry and quantification by gas chromatography or liquid chromatography. The 31 drug findings by LC/TOFMS comprised 19 different drugs-of-abuse, byproducts, and adulterants, including amphetamine and tryptamine designer drugs, with one unresolved pair of compounds having an identical mass. By the reference methods, 27 findings could be confirmed, and among the four unconfirmed findings, only 1 apparent false positive was found. In the quantitative analysis of 11 amphetamine, heroin, and cocaine findings, mean relative difference between the results of LC/CLND and the reference methods was 11% (range 4.2-21%), without any observable bias. Mean relative standard deviation for three parallel LC/CLND results was 6%. Results suggest that the present combination of LC/TOFMS and LC/CLND offers a simple solution for the analysis of scheduled and designer drugs in seized material, independent of the availability of primary reference standards.
Sun, Guangying; Liu, Yanfang; Ahat, Hasanjan; Shen, Aijin; Liang, Xinmiao; Xue, Xingya; Luo, Yuqin; Yang, Jian; Liu, Zhao-Sheng; Aisa, Haji Akber
2017-07-07
In this study, "two dimensional" molecularly imprinted solid-phase extraction (2D-MIP-SPE) of semi-preparative grade was constructed to fast purify ellagitannins in pomegranate husk extract with the help of crystallization and reverse-phase liquid chromatgoraphy (RPLC). Ellagic acid and punicalagin imprinted polymers were synthesized in batch mode and two semi-preparative MIP-SPE columns were individually packed. After investigaing "functional complementation", 2D-MIP-SPE was constructed using ellagic acid MIP and punicalagin MIP-SPE as the first and second dimension, respectively. Then, pomegranate husk extract was fast divided into four fractions individually enriching in ellagic acid, granatin A, punicalagin and ellagic acid glucoside by 2D-MIP-SPE. With the aid of crystallization and RPLC, ellagic acid (13.5mg) and punicalagin (53.4mg) were fast obtained in 30min. Ellagic acid glucoside was purified to the purity near 100% with a recovery of 86.1%. Granatin A (92%) was directly obtained by 2D-MIP-SPE with the recovery of 81.8%. All above indicated that 2D-MIP-SPE was highly efficient in natural product purification. The concept of "functional complementation" was expected to be a useful tool in the construction of 2D-MIP-SPE. Copyright © 2017 Elsevier B.V. All rights reserved.
Domínguez-Romero, Juan C; García-Reyes, Juan F; Lara-Ortega, Felipe J; Molina-Díaz, Antonio
2015-03-01
In this article, a screening method for the determination of 200 sport drugs in human urine has been developed using liquid-chromatography electrospray time-of-flight mass spectrometry (LC-TOFMS). The chromatographic separation of the targeted doping agents was carried out by fast liquid chromatography using a C18 column (4.6×50 mm) with 1.8 μm particle size. Accurate mass measurements of the selected ion (typically [M+H](+) and [M-H](-)) along with retention time matching was used for the screening and detection of the targeted species. The proposed methodology comprised also a simple sample treatment stage based on solid-phase extraction (SPE) with polymeric cartridges. The SPE method displayed satisfactory recoveries rates (between 70 and 120%) for the majority of the compounds at both concentration levels tested (2.5 and 25 μg L(-1)). The overall performance of the method was satisfactory with all 200 compounds fulfilling WADA minimum required performance levels (MRPLs), with limits of quantitation lower than 1 μg L(-1) for 80% of the compounds, and showing an appropriate linearity (r(2)>0.99) in most cases. Additionally, the ability of "in-source" collision induced dissociation (CID) for confirmatory purposes was examined using as criterion the presence of two high-resolution ions with relevant abundances for unambiguous confirmation. This stringent criterion was fulfilled for 75% of the species using in-source CID fragmentation. The use of an improved approach based on CID performed on a dedicated collision cell without precursor ion selection (using a Q-TOF) provided at least two ions in all cases with the exception of 2-aminoheptane. Finally, based on the use of diagnostic fragment ions, a workflow for the comprehensive screening and identification of non-targeted compounds (viz. compounds with no primary standards or retention time information available, such as metabolites) has been also examined using rat urine samples. The proposed screening method has proved to be effective for the analysis of targeted compounds, and also for the identification of metabolites, expanding easily the search for doping agents not only limited to specific banned parent compounds but also to derivate compounds with similar structure as well as metabolites. Copyright © 2014 Elsevier B.V. All rights reserved.
Structural and functional analysis of RopB: A major virulence regulator in Streptococcus pyogenes
Makthal, Nishanth; Gavagan, Maire; Do, Hackwon; ...
2016-02-19
Group A Streptococcus (GAS) is an exclusive human pathogen that causes significant disease burden. Global regulator RopB of GAS controls the expression of several major virulence factors including secreted protease SpeB during high cell density. However, the molecular mechanism for RopB-dependent speB expression remains unclear. To understand the mechanism of transcription activation by RopB, we determined the crystal structure of the C-terminal domain of RopB. RopB-CTD has the TPR motif, a signature motif involved in protein-peptide interactions and shares significant structural homology with the quorum sensing RRNPP family regulators. Characterization of the high cell density-specific cell-free growth medium demonstrated themore » presence of a low molecular weight proteinaceous secreted factor that upregulates RopB-dependent speB expression. Together, these results suggest that RopB and its cognate peptide signals constitute an intercellular signalling machinery that controls the virulence gene expression in concert with population density. Structure-guided mutational analyses of RopB dimer interface demonstrated that single alanine substitutions at this critical interface significantly altered RopB-dependent speB expression and attenuated GAS virulence. Finally, results presented here suggested that a properly aligned RopB dimer interface is important for GAS pathogenesis and highlighted the dimerization interactions as a plausible therapeutic target for the development of novel antimicrobials.« less
Structural and functional analysis of RopB: A major virulence regulator in Streptococcus pyogenes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makthal, Nishanth; Gavagan, Maire; Do, Hackwon
Group A Streptococcus (GAS) is an exclusive human pathogen that causes significant disease burden. Global regulator RopB of GAS controls the expression of several major virulence factors including secreted protease SpeB during high cell density. However, the molecular mechanism for RopB-dependent speB expression remains unclear. To understand the mechanism of transcription activation by RopB, we determined the crystal structure of the C-terminal domain of RopB. RopB-CTD has the TPR motif, a signature motif involved in protein-peptide interactions and shares significant structural homology with the quorum sensing RRNPP family regulators. Characterization of the high cell density-specific cell-free growth medium demonstrated themore » presence of a low molecular weight proteinaceous secreted factor that upregulates RopB-dependent speB expression. Together, these results suggest that RopB and its cognate peptide signals constitute an intercellular signalling machinery that controls the virulence gene expression in concert with population density. Structure-guided mutational analyses of RopB dimer interface demonstrated that single alanine substitutions at this critical interface significantly altered RopB-dependent speB expression and attenuated GAS virulence. Finally, results presented here suggested that a properly aligned RopB dimer interface is important for GAS pathogenesis and highlighted the dimerization interactions as a plausible therapeutic target for the development of novel antimicrobials.« less
Christiaens, B; Chiap, P; Rbeida, O; Cello, D; Crommen, J; Hubert, Ph
2003-09-25
A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).
Baker, David R; Kasprzyk-Hordern, Barbara
2011-11-04
The main aim of this manuscript is to provide a comprehensive and critical verification of methodology commonly used for sample collection, storage and preparation in studies concerning the analysis of pharmaceuticals and illicit drugs in aqueous environmental samples with the usage of SPE-LC/MS techniques. This manuscript reports the results of investigations into several sample preparation parameters that to the authors' knowledge have not been reported or have received very little attention. This includes: (i) effect of evaporation temperature and (ii) solvent with regards to solid phase extraction (SPE) extracts; (iii) effect of silanising glassware; (iv) recovery of analytes during vacuum filtration through glass fibre filters and (v) pre LC-MS filter membranes. All of these parameters are vital to develop efficient and reliable extraction techniques; an essential factor given that target drug residues are often present in the aqueous environment at ng L(-1) levels. Presented is also the first comprehensive review of the stability of illicit drugs and pharmaceuticals in wastewater. Among the parameters studied are: time of storage, temperature and pH. Over 60 analytes were targeted including stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, human urine indicators and their metabolites. The lack of stability of analytes in raw wastewater was found to be significant for many compounds. For instance, 34% of compounds studied reported a stability change >15% after only 12 h in raw wastewater stored at 2 °C; a very important finding given that wastewater is typically collected with the use of 24 h composite samplers. The stability of these compounds is also critical given the recent development of so-called 'sewage forensics' or 'sewage epidemiology' in which concentrations of target drug residues in wastewater are used to back-calculate drug consumption. Without an understanding of stability, under (or over) reporting of consumption estimations may take place. Copyright © 2011 Elsevier B.V. All rights reserved.
Tretzel, Laura; Thomas, Andreas; Piper, Thomas; Hedeland, Mikael; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario
2016-05-10
Dried blood spots (DBS) represent a sample matrix collected under minimal-invasive, straightforward and robust conditions. DBS specimens have been shown to provide appropriate test material for different analytical disciplines, e.g., preclinical drug development, therapeutic drug monitoring, forensic toxicology and diagnostic analysis of metabolic disorders in newborns. However, the sample preparation has occasionally been reported as laborious and time consuming. In order to minimize the manual workload and to substantiate the suitability of DBS for high sample-throughput, the automation of sample preparation processes is of paramount interest. In the current study, the development and validation of a fully automated DBS extraction method coupled to online solid-phase extraction using the example of nicotine, its major metabolites nornicotine, cotinine and trans-3'-hydroxycotinine and the tobacco alkaloids anabasine and anatabine is presented, based on the rationale that the use of nicotine-containing products for performance-enhancing purposes has been monitored by the World Anti-Doping Agency (WADA) for several years. Automation-derived DBS sample extracts were directed online to liquid chromatography high resolution/high mass accuracy tandem mass spectrometry, and target analytes were determined with support of four deuterated internal standards. Validation of the method yielded precise (CV <7.5% for intraday and <12.3% for interday measurements) and linear (r(2)>0.998) results. The limit of detection was established at 5 ng mL(-1) for all studied compounds, the extraction recovery ranged from 25 to 44%, and no matrix effects were observed. To exemplify the applicability of the DBS online-SPE LC-MS/MS approach for sports drug testing purposes, the method was applied to authentic DBS samples obtained from smokers, snus users, and e-cigarette users. Statistical evaluation of the obtained results indicated differences in metabolic behavior depending on the route of administration (inhalative versus buccal absorption) in terms of the ratio of nicotine and nornicotine. Copyright © 2016 Elsevier B.V. All rights reserved.
Mijangos, L; Bizkarguenaga, E; Prieto, A; Fernández, L A; Zuloaga, O
2015-04-10
The present study is focused on the development of an analytical method based on focused ultrasonic solid-liquid extraction (FUSLE) followed by dispersive solid-phase extraction (dSPE) clean-up and liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) optimised for the simultaneous analysis of certain endocrine disrupting compounds (EDCs), including alkylphenols (APs), bisphenol A (BPA), triclosan (TCS) and several hormones and sterols in vegetables (lettuce and carrot) and amended soil samples. Different variables affecting the chromatographic separation, the electrospray ionisation and mass spectrometric detection were optimised in order to improve the sensitivity of the separation and detection steps. Under the optimised extraction conditions (sonication of 5min at 33% of power with pulse times on of 0.8s and pulse times off of 0.2s in 10mL of n-hexane:acetone (30:70, v:v) mixture using an ice bath), different dSPE clean-up sorbents, such as Florisil, Envi-Carb, primary-secondary amine bonded silica (PSA) and C18, or combinations of them were evaluated for FUSLE extracts before LC-MS/MS. Apparent recoveries and precision in terms of relative standard deviation (RSDs %) of the method were determined at two different fortification levels (according to the matrix and the analyte) and values in the 70-130% and 2-27% ranges, respectively, were obtained for most of the target analytes and matrices. Matrix-matched calibration approach and the use of labelled standards as surrogates were needed for the properly quantification of most analytes and matrices. Method detection limits (MDLs), estimated with fortified samples, in the ranges of 0.1-100ng/g for carrot, 0.2-152ng/g for lettuce and 0.9-31ng/g for amended soil were obtained. The developed methodology was applied to the analysis of 11 EDCs in both real vegetable bought in a local market and in compost (from a local wastewater treatment plant, WWTP) amended soil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Atomic transport during solid-phase epitaxial recrystallization of amorphous germanium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radek, M.; Bracht, H., E-mail: bracht@uni-muenster.de; Johnson, B. C.
2015-08-24
The atomic mixing of matrix atoms during solid-phase epitaxy (SPE) is studied by means of isotopically enriched germanium (Ge) multilayer structures that were amorphized by Ge ion implantation up to a depth of 1.5 μm. Recrystallization of the amorphous structure is performed at temperatures between 350 °C and 450 °C. Secondary-ion-mass-spectrometry is used to determine the concentration-depth profiles of the Ge isotope before and after SPE. An upper limit of 0.5 nm is deduced for the displacement length of the Ge matrix atoms by the SPE process. This small displacement length is consistent with theoretical models and atomistic simulations of SPE, indicating that themore » SPE mechanism consists of bond-switching with nearest-neighbours across the amorphous-crystalline (a/c) interface.« less
Review of Peak Detection Algorithms in Liquid-Chromatography-Mass Spectrometry
Zhang, Jianqiu; Gonzalez, Elias; Hestilow, Travis; Haskins, William; Huang, Yufei
2009-01-01
In this review, we will discuss peak detection in Liquid-Chromatography-Mass Spectrometry (LC/MS) from a signal processing perspective. A brief introduction to LC/MS is followed by a description of the major processing steps in LC/MS. Specifically, the problem of peak detection is formulated and various peak detection algorithms are described and compared. PMID:20190954
Comtois-Marotte, Simon; Chappuis, Thomas; Vo Duy, Sung; Gilbert, Nicolas; Lajeunesse, André; Taktek, Salma; Desrosiers, Mélanie; Veilleux, Éloïse; Sauvé, Sébastien
2017-01-01
Trace emerging contaminants (ECs) occur in both waste and surface waters that are rich in particulates that have been found to sorb several organic contaminants. An analytical method based on off-line solid-phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) analysis was developed for the detection and quantification of 31 ECs from surface water, wastewater, suspended particulate matter (SPM) as well as sediments. Lyophilized sediments and air-dried SPM were subjected to ultrasonic extraction. Water samples and extracts were then concentrated and cleaned-up by off-line SPE. Quantification was realized using a Q Exactive mass spectrometer in both full scan (FS) and MS 2 modes. These two modes were optimized and compared to determine which one was the most suitable for each matrix studied. Yeast estrogen screen assay (YES-assay) adapted from the direct measurement of estrogenic activity without sample extraction was tested on filtered wastewater samples. An endocrine disrupting effect was detected in all effluent samples analyzed with estradiol equivalent concentrations ranging from 4.4 to 720 ng eq E2 L -1 for the WWTP-1 and 6.5-42 ng eq E2 L -1 for the WWTP-2. The analytical methods were also applied on six samples of surface water, the corresponding SPM, the sediments and thirty-nine effluent samples from two wastewater treatment plants (WWTPs) sampled over a period of five months (February to June 2014). Copyright © 2016 Elsevier Ltd. All rights reserved.
Yang, Bixia; Wang, Lian; Luo, Chunying; Wang, Xixi; Sun, Chengjun
2017-11-01
An analytical method was developed for the simultaneous determination of 11 aminoglycoside (AG) antibiotics, including amikacin, paromomycin, dihydrostreptomycin, gentamicin C1a, hygromycin, kanamycin, netilmicin, spectinomycin, sisomicin, streptomycin, and tobramycin in honey, milk, and pork samples by LC with tandem MS and molecularly imprinted polymer (MIP) SPE. The AG antibiotics in milk and homogenated meat samples were extracted with a solution composed of 10 mmol/L potassium dihydrogen phosphate, 0.4 mmol/L EDTA-Na2, and 2% trichloroacetic acid. For honey samples, the extractant was 50 mmol/L potassium dihydrogen phosphate. The extracts were cleaned up with MIP SPE cartridges. The separation was performed on a zwitter ionic-HILIC column (50 × 2.1 mm, 3.5 μm), with the mobile phase consisting of methanol, 0.3% formic acid, and 175 mmol/L ammonium formate at 0.50 mL/min in gradient elution. A triple-quadrupole mass spectrometer equipped with an electrospray ionization source, which was operated in positive mode, was used for detection. The quantification was based on matrix-matched calibration curves. The method was applied to real samples with three different matrixes. The LODs of the method were 2-30 μg/kg and the LOQs were 7-100 μg/kg; the average recovery ranged from 78.2 to 94.8%; intraday RSDs and interday RSDs were ≤15 and ≤18%, respectively; and the absolute values of matrix effect for all AGs were RSDs ≤23%.
Delgado-Povedano, M M; Calderón-Santiago, M; Priego-Capote, F; Luque de Castro, M D
2016-01-01
The determination of physiological levels of amino acids is important to aid in the diagnosis and treatment of several diseases and nutritional status of individuals. Amino acids are frequently determined in biofluids such as blood (serum or plasma) and urine; however, there are less common biofluids with different concentration profiles of amino acids that could be of interest. One of these biofluids is sweat that can be obtained in a non-invasive manner and is characterized by low complex composition. The analysis of amino acids in human sweat requires the development of sample preparation strategies according to the sample matrix and small collected volume. The influence of sample preparation on the quantitative analysis of amino acids in sweat by LC-MS/MS has been assessed through a comparison between two strategies: dilution of sweat and centrifugal microsolid-phase extraction (c-μSPE). In both cases, several dilution factors were assayed for in-depth knowledge of the matrix effects, and the use of c-μSPE provided the best results in terms of accuracy. The behavior of the target analytes was a function of the dilution factor, thus providing a pattern for sample preparation that depended on the amino acid to be determined. The concentration of amino acids in sweat ranges between 6.20 ng mL(-1) (for homocysteine) and 259.77 µg mL(-1) (for serine) with precision, expressed as relative standard deviation, within 1.1-21.4%. Copyright © 2015 Elsevier B.V. All rights reserved.
Solliec, Morgan; Massé, Daniel; Sauvé, Sébastien
2014-10-01
A new extraction method coupled to a high throughput sample analysis technique was developed for the determination of four veterinary antibiotics. The analytes belong to different groups of antibiotics such as chemotherapeutics, sulfonamides, lincosamides and macrolides. Trimethoprim (TMP), sulfadoxin (SFX), lincomycin (LCM) and tylosin (TYL) were extracted from lyophilized manure using a sonication extraction. McIlvaine buffer and methanol (MeOH) were used as extraction buffers, followed by cation-exchange solid phase extraction (SPE) for clean-up. Analysis was performed by laser diode thermal desorption-atmospheric pressure chemical-ionization (LDTD-APCI) tandem mass spectrometry (MS/MS) with selected reaction monitoring (SRM) detection. The LDTD is a high throughput sample introduction method that reduces total analysis time to less than 15s per sample, compared to minutes when using traditional liquid chromatography (LC). Various SPE parameters were optimized after sample extraction: the stationary phase, the extraction solvent composition, the quantity of sample extracted and sample pH. LDTD parameters were also optimized: solvent deposition, carrier gas, laser power and corona discharge. The method limit of detection (MLD) ranged from 2.5 to 8.3 µg kg(-1) while the method limit of quantification (MLQ) ranged from 8.3 to 28µgkg(-1). Calibration curves in the manure matrix showed good linearity (R(2)≥ 0.996) for all analytes and the interday and intraday coefficients of variation were below 14%. Recoveries of analytes from manure ranged from 53% to 69%. The method was successfully applied to real manure samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Brusniak, Mi-Youn; Bodenmiller, Bernd; Campbell, David; Cooke, Kelly; Eddes, James; Garbutt, Andrew; Lau, Hollis; Letarte, Simon; Mueller, Lukas N; Sharma, Vagisha; Vitek, Olga; Zhang, Ning; Aebersold, Ruedi; Watts, Julian D
2008-01-01
Background Quantitative proteomics holds great promise for identifying proteins that are differentially abundant between populations representing different physiological or disease states. A range of computational tools is now available for both isotopically labeled and label-free liquid chromatography mass spectrometry (LC-MS) based quantitative proteomics. However, they are generally not comparable to each other in terms of functionality, user interfaces, information input/output, and do not readily facilitate appropriate statistical data analysis. These limitations, along with the array of choices, present a daunting prospect for biologists, and other researchers not trained in bioinformatics, who wish to use LC-MS-based quantitative proteomics. Results We have developed Corra, a computational framework and tools for discovery-based LC-MS proteomics. Corra extends and adapts existing algorithms used for LC-MS-based proteomics, and statistical algorithms, originally developed for microarray data analyses, appropriate for LC-MS data analysis. Corra also adapts software engineering technologies (e.g. Google Web Toolkit, distributed processing) so that computationally intense data processing and statistical analyses can run on a remote server, while the user controls and manages the process from their own computer via a simple web interface. Corra also allows the user to output significantly differentially abundant LC-MS-detected peptide features in a form compatible with subsequent sequence identification via tandem mass spectrometry (MS/MS). We present two case studies to illustrate the application of Corra to commonly performed LC-MS-based biological workflows: a pilot biomarker discovery study of glycoproteins isolated from human plasma samples relevant to type 2 diabetes, and a study in yeast to identify in vivo targets of the protein kinase Ark1 via phosphopeptide profiling. Conclusion The Corra computational framework leverages computational innovation to enable biologists or other researchers to process, analyze and visualize LC-MS data with what would otherwise be a complex and not user-friendly suite of tools. Corra enables appropriate statistical analyses, with controlled false-discovery rates, ultimately to inform subsequent targeted identification of differentially abundant peptides by MS/MS. For the user not trained in bioinformatics, Corra represents a complete, customizable, free and open source computational platform enabling LC-MS-based proteomic workflows, and as such, addresses an unmet need in the LC-MS proteomics field. PMID:19087345
Zhou, M; Miles, C J
1991-01-01
Oxyfluorfen and oxyfluorfen amine were determined by liquid chromatography (LC) with ultraviolet (UV) and photoconductivity detection (PCD). A simple extraction procedure acceptably recovered both analytes from garbanzo beans over a wide range of fortifications (0.05 to 20 ppm) (83 +/- 4 for oxyfluorfen; 85 +/- 4 for oxyfluorfen amine). Percent recoveries decreased slightly as the fortification level decreased. Both analytes could be determined simultaneously at a concentration greater than 0.2 ppm in garbanzo beans. Detection limits were 3 ng for oxyfluorfen and 100 ng for oxyfluorfen amine using LC/UV, and 12 ng for both oxyfluorfen and oxyfluorfen amine with LC/PCD. Different knitted reaction coils and photoreactors were evaluated. Photoproduct yields and identification were determined by ion chromatography. The LC/PCD method measures oxyfluorfen and oxyfluorfen amine separately and has a shorter analysis time, while the standard method using gas chromatography measures total residues and is more sensitive.
Yuan, Su-Fen; Liu, Ze-Hua; Lian, Hai-Xian; Yang, Chuang-Tao; Lin, Qing; Yin, Hua; Lin, Zhang; Dang, Zhi
2018-02-01
A fast and reliable method was developed for simultaneous trace determination of nine odorous and estrogenic chloro- and bromo-phenolic compounds (CPs and BPs) in water samples using solid-phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). For sample preparation, the extraction efficiencies of two widely applied cartridges Oasis HLB and Sep-Pak C18 were compared, and the Oasis HLB cartridge showed much better extraction performance; pH of water sample also plays important role on extraction, and pH = 2-3 was found to be most appropriate. For separation of the target compounds, small addition of ammonium hydroxide can obviously improve the detection sensitivity, and the optimized addition concentration was determined as 0.2%. The developed efficient method was validated and showed excellent linearity (R 2 > 0.995), low limit of detection (LOD, 1.9-6.2 ng/L), and good recovery efficiencies of 57-95% in surface and tap water with low relative standard deviation (RSD, 1.3-17.4%). The developed method was finally applied to one tap and one surface water samples and most of these nine targets were detected, but all of them were below their odor thresholds, and their estrogen equivalent (EEQ) were also very low.
Senyuva, Hamide Z; Gökmen, Vural
2005-03-01
An improved analytical method for the determination of acrylamide in coffee is described using liquid chromatography coupled to mass spectrometric detection (LC-MS). A variety of instant, ground and laboratory roasted coffee samples were analysed using this method. The sample preparation entails extraction of acrylamide with methanol, purification with Carrez I and II solutions, evaporation and solvent change to water, and clean-up with an Oasis HLB solid-phase extraction (SPE) cartridge. The chromatographic conditions allowed separation of acrylamide and the remaining matrix co-extractives with accurate and precise quantification of acrylamide during MS detection in SIM mode. Recoveries for the spiking levels of 50, 100, 250 and 500?microg/kg ranged between 99 and 100% with relative standard deviations of less than 2%. The effects of roasting on the formation of acrylamide and colour development were also investigated at 150, 200 and 225 degrees C. Change in the CIE (Commission Internationale de l'Eclairage) a* colour value was found to show a good correlation with the change in acrylamide. CIE a* and acrylamide data was fitted to a non-linear logarithmic function for the estimation of acrylamide level in coffee. Measured acrylamide levels in commercial roasted coffees compared well with the predicted acrylamide levels from the CIE a* values.
Calderón-Santiago, M; Priego-Capote, F; Jurado-Gámez, B; Luque de Castro, M D
2014-03-14
Sweat has recently gained popularity as a potential tool for diagnostics and biomarker monitoring as it is a non-invasive biofluid the composition of which could be modified by certain pathologies, as is the case with cystic fibrosis, which increases chloride levels in sweat. The aim of the present study was to develop an analytical method for analysis of human sweat by liquid chromatography-mass spectrometry (LC-Q-TOF MS/MS) in high resolution mode. Thus, different sample preparation strategies and different chromatographic modes (HILIC and C18 reverse modes) were compared to check their effect on the profile of sweat metabolites. Forty-one compounds were identified by the MS/MS information obtained with a mass tolerance window below 4 ppm. Amino acids, dicarboxylic acids and other interesting metabolites such as inosine, choline, uric acid and tyramine were identified. Among the tested protocols, direct analysis after dilution was a suited option to obtain a representative snapshot of sweat metabolome. In addition, sample clean up by C18 SpinColumn SPE cartridges improved the sensitivity of most identified compounds and reduced the number of interferents. As most of the identified metabolites are involved in key biochemical pathways, this study opens new possibilities to the use of sweat as a source of metabolite biomarkers of specific disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
Křesinová, Zdena; Linhartová, Lucie; Petrů, Klára; Krejčová, Lucie; Šrédlová, Kamila; Lhotský, Ondřej; Kameník, Zdeněk; Cajthaml, Tomáš
2016-04-01
A rapid and reliable analytical method was developed for the quantitative determination of psychopharmaceuticals, their precursors and by-products in real contaminated samples from a pharmaceutical company in Olomouc (Czech Republic), based on SPE disk extraction and detection by ultra performance liquid chromatography, combined with time-of-flight mass spectrometry. The target compounds were quantified in the real whole-water samples (water including suspended particles), both in the presence of suspended particulate matter (SPM) and high concentrations of other organic pollutants. A total of nine compounds were analyzed which consisted of three commonly used antidepressants (tricyclic antidepressants and antipsychotics), one antitussive agent and five by-products or precursors. At first, the SPE disk method was developed for the extraction of water samples (dissolved analytes, recovery 84-104%) and pressurised liquid extraction technique was verified for solid matrices (sludge samples, recovery 81-95%). In order to evaluate the SPE disk technique for whole water samples containing SPM, non contaminated groundwater samples were also loaded with different amounts (100 and 300mgL(-1)) of real contaminated sludge originating from the same locality. The recoveries from the whole-water samples obtained by SPE disk method ranged between 67 and 119% after the addition of the most contaminated sludge. The final method was applied to several real groundwater (whole-water) samples from the industrial area and high concentrations (up to 10(3)μgL(-1)) of the target compounds were detected. The results of this study document and indicate the feasibility of the SPE disk method for analysis of groundwater. Copyright © 2016 Elsevier B.V. All rights reserved.
Developments in coupled solid-phase extraction-capillary electrophoresis 2013-2015.
Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J
2016-01-01
An overview of the design and application of coupled solid-phase extraction-capillary electrophoresis (SPE-CE) systems reported in the literature between July 2013 and June 2015 is provided in this paper. The present article is a continuation of our previous review papers on this topic which covered the time period 2000-2013 (Electrophoresis 2008, 29, 108-128; Electrophoresis 2010, 31, 44-54; Electrophoresis 2012, 33, 243-250; Electrophoresis 2014, 35, 128-137). The use of in-line and on-line SPE-CE approaches is treated and outlined in this review. Recent advancements, such as, for example, the use of aptamers as affinity material for in-line SPE-CE, the use of a bead string design for in-line fritless SPE-CE, and new interfacing techniques for the on-line coupling of SPE to CE, are outlined. Selected examples demonstrate the applicability of the coupled SPE-CE systems for biomedical, pharmaceutical, environmental, and food studies. A complete overview of the recent SPE-CE studies is given in table format, providing information on sample type, SPE sorbent, coupling mode, detection mode, and LOD. Finally, some general conclusions and perspectives are provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cassada, D A; Monson, S J; Snow, D D; Spalding, R F
1999-06-04
Recent improvements in the LC-MS interface have increased the sensitivity and selectivity of this instrument in the analysis of polar and thermally-labile aqueous constituents. Determination of RDX, nitroso-RDX metabolites, and other munitions was enhanced using LC-MS with solid-phase extraction, 15N3-RDX internal standard, and electrospray ionization (ESI) in negative ion mode. ESI produced a five-fold increase in detector response over atmospheric pressure chemical ionization (APCI) for the nitramine compounds, while the more energetic APCI produced more than twenty times the ESI response for nitroaromatics. Method detection limits in ESI for nitramines varied from 0.03 microgram l-1 for MNX to 0.05 microgram l-1 for RDX.
Drzymala, Sarah S; Weiz, Stefan; Heinze, Julia; Marten, Silvia; Prinz, Carsten; Zimathies, Annett; Garbe, Leif-Alexander; Koch, Matthias
2015-05-01
Established maximum levels for the mycotoxin zearalenone (ZEN) in edible oil require monitoring by reliable analytical methods. Therefore, an automated SPE-HPLC online system based on dynamic covalent hydrazine chemistry has been developed. The SPE step comprises a reversible hydrazone formation by ZEN and a hydrazine moiety covalently attached to a solid phase. Seven hydrazine materials with different properties regarding the resin backbone, pore size, particle size, specific surface area, and loading have been evaluated. As a result, a hydrazine-functionalized silica gel was chosen. The final automated online method was validated and applied to the analysis of three maize germ oil samples including a provisionally certified reference material. Important performance criteria for the recovery (70-120 %) and precision (RSDr <25 %) as set by the Commission Regulation EC 401/2006 were fulfilled: The mean recovery was 78 % and RSDr did not exceed 8 %. The results of the SPE-HPLC online method were further compared to results obtained by liquid-liquid extraction with stable isotope dilution analysis LC-MS/MS and found to be in good agreement. The developed SPE-HPLC online system with fluorescence detection allows a reliable, accurate, and sensitive quantification (limit of quantification, 30 μg/kg) of ZEN in edible oils while significantly reducing the workload. To our knowledge, this is the first report on an automated SPE-HPLC method based on a covalent SPE approach.
USDA-ARS?s Scientific Manuscript database
This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...
Razavi, Morteza; Frick, Lauren E; LaMarr, William A; Pope, Matthew E; Miller, Christine A; Anderson, N Leigh; Pearson, Terry W
2012-12-07
We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.
Ge, Liya; Yong, Jean Wan Hong; Tan, Swee Ngin; Yang, Xin Hao; Ong, Eng Shi
2004-09-03
Micellar electrokinetic capillary chromatography (MECC) was developed for the separation of cytokinins including trans-zeatin, trans-zeatin-O-glucoside, dihydrozeatin, dihydrozeatin-O-glucoside, meta-topolin riboside, N6-isopentenyladenine and N6-benzylaminopurine. Under the optimum conditions, i.e. a combination of 10 mM phosphate and 10 mM borate as the running buffer containing 50 mM sodium dodecyl sulphate at pH 10.4, the separation of seven cytokinin standards was accomplished within 11 min. The C18 solid-phase extraction (SPE) method was used to pre-concentrate the putative cytokinins present in the coconut water. Following which, the eluate was further purified using mixed mode Oasis MCX SPE columns and this additional step helps to reduce matrix interference during MECC. After the two solid-phase extraction steps, the optimized MECC method was able to screen for certain cytokinins (zeatin-O-glucoside and dihydrozeatin-O-glucoside) present in coconut water. After this screening, the presence of zeatin-O-glucoside and dihydrozeatin-O-glucoside in coconut water was further confirmed by independent high-performance liquid chromatography and liquid chromatography-mass spectrometry experiments.
Qiao, Jindong; Wang, Mingyu; Yan, Hongyuan; Yang, Gengliang
2014-04-02
A new magnetic dummy molecularly imprinted dispersive solid-phase extraction (MAG-MIM-dSPE) coupled with gas chromatography-FID was developed for selective determination of phthalates in plastic bottled beverages. The new magnetic dummy molecularly imprinted microspheres (MAG-MIM) using diisononyl phthalate as a template mimic were synthesized by coprecipitation coupled with aqueous suspension polymerization and were successfully applied as the adsorbents for MAG-MIM-dSPE to extract and isolate five phthalates from plastic bottled beverages. Validation experiments showed that the MAG-MIM-dSPE method had good linearity at 0.0040-0.40 μg/mL (0.9991-0.9998), good precision (3.1-6.9%), and high recovery (89.5-101.3%), and limits of detection were obtained in a range of 0.53-1.2 μg/L. The presented MAG-MIM-dSPE method combines the quick separation of magnetic particles, special selectivity of MIM, and high extraction efficiency of dSPE, which could potentially be applied to selective screening of phthalates in beverage products.
Hwang, Taeik; Noh, Eunyoung; Jeong, Ji Hye; Park, Sung-Kwan; Shin, Dongwoo; Kang, Hoil
2018-02-28
A sensitive and specific high-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (LC-QTOF-MS) method combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of grayanotoxins I and III in dietary supplements and homemade wine. Grayanotoxins I and III were successfully extracted using solid-phase extraction cartridges, characterized by LC-QTOF-MS, and quantitated by LC-MS/MS. The LC-MS/MS calibration curves were linear over concentrations of 10-100 ng/mL (grayanotoxin I) and 20-400 ng/mL (grayanotoxin III). Grayanotoxins I and III were found in 51 foodstuffs, with quantitative determinations revealing total toxin concentrations of 18.4-101 000 ng/mL (grayanotoxin I) and 15.3-56 000 ng/mL (grayanotoxin III). The potential of the validated method was demonstrated by successful quantitative analysis of grayanotoxins I and III in dietary supplements and homemade wine; the method appears suitable for the routine detection of grayanotoxins I and III from Rhododendron brachycarpum.
Duarte, Mariana; Jagadeesan, Kishore Kumar; Billing, Johan; Yilmaz, Ecevit; Laurell, Thomas; Ekström, Simon
2017-10-13
Phosphatidylethanol (PEth) is an interesting biomarker finding increased use for detecting long term alcohol abuse with high specificity and sensitivity. Prior to detection, sample preparation is an unavoidable step in the work-flow of PEth analysis and new protocols may facilitate it. Solid-phase extraction (SPE) is a versatile sample preparation method widely spread in biomedical laboratories due to its simplicity of use and the possibility of automation. In this work, SPE was used for the first time to directly extract PEth from spiked human plasma and spiked human blood. A library of polymeric SPE materials with different surface functionalities was screened for PEth extraction in order to identify the surface characteristics that control PEth retention and recovery. The plasma samples were diluted 1:10 (v/v) in water and spiked at different concentrations ranging from 0.3 to 5μM. The library of SPE materials was then evaluated using the proposed SPE method and detection was done by LC-MS/MS. One SPE material efficiently retained and recovered PEth from spiked human plasma. With this insight, four new SPE materials were formulated and synthesized based on the surface characteristics of the best SPE material found in the first screening. These new materials were tested with spiked human blood, to better mimic a real clinical sample. All the newly synthetized materials outperformed the pre-existing commercially available materials. Recovery values for the new SPE materials were found between 29.5% and 48.6% for the extraction of PEth in spiked blood. A material based on quaternized 1-vinylimidazole with a poly(trimethylolpropane trimethacrylate) backbone was found suitable for PEth extraction in spiked blood showing the highest analyte recovery in this experiment, 48.6%±6.4%. Copyright © 2017 Elsevier B.V. All rights reserved.
ChelomEx: Isotope-assisted discovery of metal chelates in complex media using high-resolution LC-MS.
Baars, Oliver; Morel, François M M; Perlman, David H
2014-11-18
Chelating agents can control the speciation and reactivity of trace metals in biological, environmental, and laboratory-derived media. A large number of trace metals (including Fe, Cu, Zn, Hg, and others) show characteristic isotopic fingerprints that can be exploited for the discovery of known and unknown organic metal complexes and related chelating ligands in very complex sample matrices using high-resolution liquid chromatography mass spectrometry (LC-MS). However, there is currently no free open-source software available for this purpose. We present a novel software tool, ChelomEx, which identifies isotope pattern-matched chromatographic features associated with metal complexes along with free ligands and other related adducts in high-resolution LC-MS data. High sensitivity and exclusion of false positives are achieved by evaluation of the chromatographic coherence of the isotope pattern within chromatographic features, which we demonstrate through the analysis of bacterial culture media. A built-in graphical user interface and compound library aid in identification and efficient evaluation of results. ChelomEx is implemented in MatLab. The source code, binaries for MS Windows and MAC OS X as well as test LC-MS data are available for download at SourceForge ( http://sourceforge.net/projects/chelomex ).
NASA Astrophysics Data System (ADS)
García-Galán, M. a. Jesús; Garrido, Teresa; Fraile, Josep; Ginebreda, Antoni; Díaz-Cruz, M. Silvia; Barceló, Damià
2010-03-01
SummaryIn the present work the occurrence of 19 selected sulfonamides, including one acetylated metabolite, was investigated in ground water samples taken from two ground water bodies in Catalonia (Plana de Vic and La Selva). Both include areas designated as nitrate vulnerable zones, according to Directive 91/676/EEC. A fully automated analytical methodology based on on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (on-line SPE-LC-MS/MS) was developed for this purpose. The high selectivity and sensitivity achieved (limits of detection between 0.005 and 0.8 ng/L) permitted to demonstrate the ubiquity of these antibiotics in both ground water bodies. Results showed a wide range of concentrations, from 0.01 ng/L up to 3460.57 ng/L. Since sulfonamides are related to livestock veterinary practices, they can be used as a specific indicator of manure contamination. However, the presence of sulfonamides appeared not to be directly related to the concentration of nitrates, as it is reflected on the low correlation coefficients found.
Lipidomics of tobacco leaf and cigarette smoke.
Dunkle, Melissa N; Yoshimura, Yuta; T Kindt, Ruben; Ortiz, Alexia; Masugi, Eri; Mitsui, Kazuhisa; David, Frank; Sandra, Pat; Sandra, Koen
2016-03-25
Detailed lipidomics experiments were performed on the extracts of cured tobacco leaf and of cigarette smoke condensate (CSC) using high-resolution liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-Q-TOF MS). Following automated solid-phase extraction (SPE) fractionation of the lipid extracts, over 350 lipids could be annotated. From a large-scale study on 22 different leaf samples, it was determined that differentiation based on curing type was possible for both the tobacco leaf and the CSC extracts. Lipids responsible for the classification were identified and the findings were correlated to proteomics data acquired from the same tobacco leaf samples. Prediction models were constructed based on the lipid profiles observed in the 22 leaf samples and successfully allowed for curing type classification of new tobacco leaves. A comparison of the leaf and CSC data provided insight into the lipidome changes that occur during the smoking process. It was determined that lipids which survive the smoking process retain the same curing type trends in both the tobacco leaf and CSC data. Copyright © 2015 Elsevier B.V. All rights reserved.
Water-Soluble Dried Blood Spot in Protein Analysis: A Proof-of-Concept Study.
Rosting, Cecilie; Gjelstad, Astrid; Halvorsen, Trine Grønhaug
2015-08-04
In the present work human chorionic gonadotropin (hCG) was used as a model protein in a proof-of-concept study combining water-soluble dried blood spot (DBS) material in liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based protein analysis. A water-soluble material consisting of commercially available carboxymethyl cellulose (CMC) was evaluated as sampling material for this purpose. The material dissolved readily at physiological pH. Different sample preparation methods were evaluated, and in the final method, 15 μL of whole blood was deposited and dried on CMC before the whole spot was dissolved prior to cleanup by immunoaffinity extraction, tryptic digest, and preconcentration by solid-phase extraction (SPE). The results indicated complete dissolution of hCG from the spots, acceptable limit of detection (LOD) (0.1 IU/mL), linearity (R(2) = 0.959), accuracy (16%), and precision (≤22%). Long-term stability (45 days) of hCG in dried spots at reduced temperatures (≤8 °C) was also demonstrated. The analyte recovery was comparable to the commercially available nonsolvable cellulose material (FTA DMPK-C card).
Batista-Andrade, Jahir Antonio; Caldas, Sergiane Souza; de Oliveira Arias, Jean Lucas; Castro, Italo Braga; Fillmann, Gilberto; Primel, Ednei Gilberto
2016-11-15
A baseline study for antifouling booster biocides in coastal waters of Panama is presented. Solid Phase Extraction (SPE) was used for extraction and Liquid Chromatography tandem Mass Spectrometry (LC-MS/MS) was applied for the quantification of irgarol 1051, diuron, (2-thiocyanomethylthio)benzothiazole (TCMTB), 4,5-dichloro-2-n-octyl-4-isothiazolin-3-one (DCOIT) and dichlofluanid. TCMTB, DCOIT and dichlofluanid were not detected in any seawater sample, while irgarol 1051 and diuron were found in four out of thirteen areas (<0.3 to 5.0ngL -1 and <2.7 to 70ngL -1 , respectively). Although the hotspots were identified in areas influenced by marinas and in one of the ports, diuron and irgarol 1051 levels were all lower than the threshold levels set by the Environmental Quality Standard of United Kingdom. However, this is only a snapshot of the status of costal water contamination by antifouling booster biocides and a more comprehensive assessment is needed to assess risks associated to long term exposure. Copyright © 2016. Published by Elsevier Ltd.
Abd-Elsalam, Heba-Alla H; Al-Ghobashy, Medhat A; Zaazaa, Hala E; Ibrahim, Mohamed A
2014-08-01
Epigallocatechin gallate (EGCG) is a powerful antioxidant and commonly used nutraceutical. Accelerated stability of EGCG in tablet formulations was investigated. LLE and SPE were employed for sample clean-up and enrichment of EGCG over caffeine. Samples were analysed after spiking with fixed concentration of gallic acid (GA), in order to verify reproducibility of analysis. A TLC-densitometric assay was developed and validated for determination of % loss EGCG. EGCG, GA and caffeine were resolved with Rf values 0.54, 0.69 and 0.80, respectively. LC-MS/MS was used to verify identity and purity of the EGCG band. Determination was carried out over a concentration range of 0.50-5.00μg/band and 0.20-2.40μg/band for GA and caffeine, respectively. Results showed significant reduction in EGCG content after one, three and six months: 24.00%, 28.00% and 52.00% respectively. Results continue to demonstrate that stability of nutraceutical products should be investigated in-depth using industry-oriented protocols before granting marketing authorisation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Filippova, Ekaterina V; Weigand, Steven; Osipiuk, Jerzy; Kiryukhina, Olga; Joachimiak, Andrzej; Anderson, Wayne F
2015-11-06
The spermidine N-acetyltransferase SpeG is a dodecameric enzyme that catalyzes the transfer of an acetyl group from acetyl coenzyme A to polyamines such as spermidine and spermine. SpeG has an allosteric polyamine-binding site and acetylating polyamines regulate their intracellular concentrations. The structures of SpeG from Vibrio cholerae in complexes with polyamines and cofactor have been characterized earlier. Here, we present the dodecameric structure of SpeG from V. cholerae in a ligand-free form in three different conformational states: open, intermediate and closed. All structures were crystallized in C2 space group symmetry and contain six monomers in the asymmetric unit cell. Two hexamers related by crystallographic 2-fold symmetry form the SpeG dodecamer. The open and intermediate states have a unique open dodecameric ring. This SpeG dodecamer is asymmetric except for the one 2-fold axis and is unlike any known dodecameric structure. Using a fluorescence thermal shift assay, size-exclusion chromatography with multi-angle light scattering, small-angle X-ray scattering analysis, negative-stain electron microscopy and structural analysis, we demonstrate that this unique open dodecameric state exists in solution. Our combined results indicate that polyamines trigger conformational changes and induce the symmetric closed dodecameric state of the protein when they bind to their allosteric sites. Copyright © 2015. Published by Elsevier Ltd.
Filippova, Ekaterina V.; Weigand, Steven J.; Osipiuk, Jerzy; ...
2015-09-26
The spermidine N-acetyltransferase SpeG is a dodecameric enzyme that catalyzes the transfer of an acetyl group from acetyl coenzyme A to polyamines such as spermidine and spermine. SpeG has an allosteric polyamine-binding site and acetylating polyamines regulate their intracellular concentrations. The structures of SpeG from Vibrio cholerae in complexes with polyamines and cofactor have been characterized earlier. Here, we present the dodecameric structure of SpeG from V. cholerae in a ligand-free form in three different conformational states: open, intermediate and closed. All structures were crystallized in C2 space group symmetry and contain six monomers in the asymmetric unit cell. Twomore » hexamers related by crystallographic 2-fold symmetry form the SpeG dodecamer. The open and intermediate states have a unique open dodecameric ring. This SpeG dodecamer is asymmetric except for the one 2-fold axis and is unlike any known dodecameric structure. Using a fluorescence thermal shift assay, size-exclusion chromatography with multi-angle light scattering, small-angle X-ray scattering analysis, negative-stain electron microscopy and structural analysis, we demonstrate that this unique open dodecameric state exists in solution. As a result, our combined results indicate that polyamines trigger conformational changes and induce the symmetric closed dodecameric state of the protein when they bind to their allosteric sites.« less
Van Damme, Thomas; Zhang, Yanhua; Lynen, Frédéric; Sandra, Pat
2012-11-15
3',5'-Cyclic guanosine monophosphate (cGMP) and 3',5'-cyclic adenosine monophosphate (cAMP) are essential second messenger molecules. They are involved in signal transduction within cells, in physiological functions such as neurotransmission and in the modulation of cell growth and differentiation of organisms, respectively. A quantitative solid phase extraction method (SPE) based on hydrophilic interaction on silica was developed and applied to both plasma and tissue samples. The stable isotope-labeled internal standards ²D₁, ¹⁵N₃-3',5'-cGMP and ¹³C₁₀, ¹⁵N₅-3',5'-cAMP were added prior to the sample preparation to ensure high precision and accuracy. The samples were analyzed by reversed-phase liquid chromatography (RP-LC). Negative electrospray (ESI)-MS/MS was used to selectively monitor several transitions of each metabolite. The method for the analysis of 3',5'-cAMP and 3',5'-cGMP in plasma was validated in the range of 0.15-20 ng/mL (R²=0.9996 and 0.9994 for 3',5'-cAMP and 3',5'-cGMP, respectively). Basal plasma concentrations for fifteen healthy human patients determined with this method varied between 4.66-9.20 ng/mL for 3',5'-cAMP and between 0.30-1.20 ng/mL for 3',5'-cGMP, with precisions better than 9.1%. 3',5'-cGMP and 3',5'-cAMP together with their 2',3'-isomers were also determined in a semi quantitative way in animal tissues. The structures of the isomers were confirmed by analysis with LC-high resolution time-of-flight MS and subsequently by comparison of retention times with standards. Copyright © 2012 Elsevier B.V. All rights reserved.
Gros, Meritxell; Petrović, Mira; Barceló, Damiá
2006-11-15
This paper describes development, optimization and validation of a method for the simultaneous determination of 29 multi-class pharmaceuticals using off line solid phase extraction (SPE) followed by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS). Target compounds include analgesics and non-steroidal anti-inflammatories (NSAIDs), lipid regulators, psychiatric drugs, anti-histaminics, anti-ulcer agent, antibiotics and beta-blockers. Recoveries obtained were generally higher than 60% for both surface and wastewaters, with exception of several compounds that yielded lower, but still acceptable recoveries: ranitidine (50%), sotalol (50%), famotidine (50%) and mevastatin (34%). The overall variability of the method was below 15%, for all compounds and all tested matrices. Method detection limits (MDL) varied between 1 and 30ng/L and from 3 to 160ng/L for surface and wastewaters, respectively. The precision of the method, calculated as relative standard deviation (R.S.D.), ranged from 0.2 to 6% and from 1 to 11% for inter and intra-day analysis, respectively. A detailed study of matrix effects was performed in order to evaluate the suitability of different calibration approaches (matrix-matched external calibration, internal calibration, extract dilution) to reduce analyte suppression or enhancement during instrumental analysis. The main advantages and drawbacks of each approach are demonstrated, justifying the selection of internal standard calibration as the most suitable approach for our study. The developed analytical method was successfully applied to the analysis of pharmaceutical residues in WWTP influents and effluents, as well as in river water. For both, river and wastewaters, the most ubiquitous compounds belonged to the group of anti-inflammatories and analgesics, antibiotics, the lipid regulators being acetaminophen, trimethoprim, ibuprofen, ketoprofen, atenolol, propranolol, mevastatin, carbamazepine and ranitidine the most frequently detected compounds.
Chambers, Andrew G.; Mellors, J. Scott; Henley, W. Hampton; Ramsey, J. Michael
2011-01-01
A microfluidic device capable of two-dimensional reversed-phase liquid chromatography-capillary electrophoresis with integrated electrospray ionization (LC-CE-ESI) for mass spectrometry (MS)-based proteomic applications is described. Traditional instrumentation was used for the LC sample injection and delivery of the LC mobile phase. The glass microfabricated device incorporated a sample-trapping region and an LC channel packed with reversed-phase particles. Rapid electrokinetic injections of the LC effluent into the CE dimension were performed at a cross channel intersection. The CE separation channel terminated at a corner of the square device, which functioned as an integrated electrospray tip. In addition to LC-CE-ESI, this device was used for LC-ESI without any instrumental modifications. To evaluate the system, LC-MS and LC-CE-MS analysis of protein digests were performed and compared. PMID:21214194
De Beer, Maarten; Lynen, Fréderic; Chen, Kai; Ferguson, Paul; Hanna-Brown, Melissa; Sandra, Pat
2010-03-01
Stationary-phase optimized selectivity liquid chromatography (SOS-LC) is a tool in reversed-phase LC (RP-LC) to optimize the selectivity for a given separation by combining stationary phases in a multisegment column. The presently (commercially) available SOS-LC optimization procedure and algorithm are only applicable to isocratic analyses. Step gradient SOS-LC has been developed, but this is still not very elegant for the analysis of complex mixtures composed of components covering a broad hydrophobicity range. A linear gradient prediction algorithm has been developed allowing one to apply SOS-LC as a generic RP-LC optimization method. The algorithm allows operation in isocratic, stepwise, and linear gradient run modes. The features of SOS-LC in the linear gradient mode are demonstrated by means of a mixture of 13 steroids, whereby baseline separation is predicted and experimentally demonstrated.
Nanomaterials as stationary phases and supports in liquid chromatography.
Beeram, Sandya R; Rodriguez, Elliott; Doddavenkatanna, Suresh; Li, Zhao; Pekarek, Allegra; Peev, Darin; Goerl, Kathryn; Trovato, Gianfranco; Hofmann, Tino; Hage, David S
2017-10-01
The development of various nanomaterials over the last few decades has led to many applications for these materials in liquid chromatography (LC). This review will look at the types of nanomaterials that have been incorporated into LC systems and the applications that have been explored for such systems. A number of carbon-based nanomaterials and inorganic nanomaterials have been considered for use in LC, ranging from carbon nanotubes, fullerenes and nanodiamonds to metal nanoparticles and nanostructures based on silica, alumina, zirconia and titanium dioxide. Many ways have been described for incorporating these nanomaterials into LC systems. These methods have included covalent immobilization, adsorption, entrapment, and the synthesis or direct development of nanomaterials as part of a chromatographic support. Nanomaterials have been used in many types of LC. These applications have included the reversed-phase, normal-phase, ion-exchange, and affinity modes of LC, as well as related methods such as chiral separations, ion-pair chromatography and hydrophilic interaction liquid chromatography. Both small and large analytes (e.g., dyes, drugs, amino acids, peptides and proteins) have been used to evaluate possible applications for these nanomaterial-based methods. The use of nanomaterials in columns, capillaries and planar chromatography has been considered as part of these efforts. Potential advantages of nanomaterials in these applications have included their good chemical and physical stabilities, the variety of interactions many nanomaterials can have with analytes, and their unique retention properties in some separation formats. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lintelmann, Jutta; Wu, Xiao; Kuhn, Evelyn; Ritter, Sebastian; Schmidt, Claudia; Zimmermann, Ralf
2018-05-01
A high-performance liquid chromatographic (HPLC) method with integrated solid-phase extraction for the determination of 1-hydroxypyrene and 1-, 2-, 3-, 4- and 9-hydroxyphenanthrene in urine was developed and validated. After enzymatic treatment and centrifugation of 500 μL urine, 100 μL of the sample was directly injected into the HPLC system. Integrated solid-phase extraction was performed on a selective, copper phthalocyanine modified packing material. Subsequent chromatographic separation was achieved on a pentafluorophenyl core-shell column using a methanol gradient. For quantification, time-programmed fluorescence detection was used. Matrix-dependent recoveries were between 94.8 and 102.4%, repeatability and reproducibility ranged from 2.2 to 17.9% and detection limits lay between 2.6 and 13.6 ng/L urine. A set of 16 samples from normally exposed adults was analyzed using this HPLC-fluorescence detection method. Results were comparable with those reported in other studies. The chromatographic separation of the method was transferred to an ultra-high-performance liquid chromatography pentafluorophenyl core-shell column and coupled to a high-resolution time-of-flight mass spectrometer (HR-TOF-MS). The resulting method was used to demonstrate the applicability of LC-HR-TOF-MS for simultaneous target and suspect screening of monohydroxylated polycyclic aromatic hydrocarbons in extracts of urine and particulate matter. Copyright © 2018 John Wiley & Sons, Ltd.
Hladik, Michelle; Calhoun, Daniel L.
2012-01-01
A method for the determination of the widely used herbicide diuron, three degradates of diuron, and six neonicotinoid insecticides in environmental water samples is described. Filtered water samples were extracted by using solid-phase extraction (SPE) with no additional cleanup steps. Quantification of the pesticides from the extracted water samples was done by using liquid chromatography with tandem mass spectrometry (LC/MS/MS). Recoveries in test water samples fortified at 20 nanograms per liter (ng/L) for each compound ranged from 75 to 97 percent; relative standard deviations ranged from 5 to 10 percent. Method detection limits (MDLs) in water ranged from 3.0 to 6.2 ng/L using LC/MS/MS. The method was applied to water samples from two streams in Georgia, Sope Creek and the Chattahoochee River. Diuron and 3,4-dichloroaniline (3,4-DCA) were detected in 100 and 80 percent, respectively, of the samples from the Chattahoochee River, whereas Sope creek had detection frequencies of 15 percent for diuron and 31 percent for 3,4-DCA. Detection frequencies for the neonicotinoid insecticide, imidacloprid, were 60 percent for the Chattahoochee River and 85 percent for Sope Creek. Field matrix-spike recoveries for each compound, when averaged over four water samples, ranged from 79 to 100 percent. The average percentage difference between replicate pairs for all compounds detected in the field samples was 10.1 (± 4.5) percent.
Imbert, L; Dulaurent, S; Mercerolle, M; Morichon, J; Lachâtre, G; Gaulier, J-M
2014-01-01
The two major challenges in hair analysis are the limited amount of samples usually available and the low targeted concentrations. To overcome these limitations, a liquid chromatography-electrospray-tandem mass spectrometry method (LC-ESI-MS/MS) allowing the simultaneous analysis of 17 amphetamines (amphetamine, BDB, m-CPP, dexfenfluramine, DOB, DOM, ephedrine, MBDB, MDA, MDEA, MDMA, methamphetamine, methylphenidate, 4-MTA, norephedrine, norfenfluramine and PMA), 5 opiates (morphine, codeine, heroin, ethylmorphine, and 6AM), cocaine and 5 metabolites [ecgonine methyl ester (EME), benzoylecgonine (BZE), anhydroecgonine methyl ester (AME), cocaethylene, and norcocaine] has been developed. The validation procedure included linearity, intra-day and inter-day variability and accuracy for 5 days (5 replicates at 3 concentration levels). Proficiency studies were used to check the accuracy of the method. As a result, all amphetamines, opiates and cocaine derivatives were satisfactory identified by 2 MRM transitions in 15 min. Calibration curves were performed by a quadratic 1/X weighted regression. The calibration model fits from 0.05 to 10 ng/mg. The limits of detection (LODs) range between 0.005 and 0.030 ng/mg. Precision has been checked by intra-day and inter-day RSD, and associated relative bias, which were lower than 25% for the limits of quantifications (LOQs) and lower than 20% for the other levels tested. This method was routinely applied to hair samples: two positive results of adult drug addicts are presented. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Zhang, Yiping; Chen, Dawei; Hong, Zhuan
2015-01-01
In this study, we developed a self-assembly pipette tip solid-phase extraction (PTSPE) method using a high molecular weight polymer material (PAX) as the adsorbent for the determination of domoic acid (DA) in human urine samples by liquid chromatography high-resolution mass spectrometry (LC-HRMS) analysis. The PTSPE cartridge, assembled by packing 9.1 mg of PAX as sorbent into a 200 μL pipette tip, showed high adsorption capacity for DA owing to the strong cationic properties of PAX. Compared with conventional SPE, the PTSPE is simple and fast, and shows some advantages in the aspects of less solvent consumption, low cost, the absence of the evaporation step, and short time requirement. All the parameters influencing the extraction efficiency such as pH, the amount of sorbent, the number of aspirating/dispensing cycles, and the type and volume of eluent in PTSPE were carefully investigated and optimized. Under the optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) values of DA were 0.12 μg/L and 0.37 μg/L respectively. The extraction recoveries of DA from the urine samples spiked at four different concentrations were in a range from 88.4% to 102.5%. The intra- and inter-day precisions varied from 2.1% to 7.6% and from 2.6% to 12.7%, respectively. The accuracy ranged from −1.9% to −7.4%. PMID:26729165
Yamazaki, K; Ogiso, M; Isagawa, S; Urushiyama, T; Ukena, T; Kibune, N
2013-01-01
A new, direct analytical method for the determination of 3-chloro-1,2-propanediol fatty acid esters (3-MCPD esters) was developed. The targeted 3-MCPD esters included five types of monoester and 25 [corrected] types of diester. Samples (oils and fats) were dissolved in a mixture of tert-butyl methyl ether and ethyl acetate (4:1), purified using two solid-phase extraction (SPE) cartridges (C(18) and silica), then analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Five monoesters and five diesters with the same fatty acid group could be separated and quantified. Pairs of 3-MCPD diesters carrying the same two different fatty acid groups, but at reversed positions (sn-1 and sn-2), could not be separated and so were expressed as a sum of both compounds. The limits of quantification (LOQs) were estimated to be between 0.02 to 0.08 mg kg(-1), depending on the types of 3-MCPD ester. Repeatability expressed as relative standard deviation (RSD(r)%) varied from 5.5% to 25.5%. The new method was shown to be applicable to various commercial edible oils and showed levels of 3-MCPD esters varying from 0.58 to 25.35 mg kg(-1). The levels of mono- and diesters ranged from 0.10 to 0.69 mg kg(-1) and from 0.06 to 16 mg kg(-1), respectively.
Barbosa, Marta O; Ribeiro, Ana R; Pereira, Manuel F R; Silva, Adrián M T
2016-11-01
Organic micropollutants present in drinking water (DW) may cause adverse effects for public health, and so reliable analytical methods are required to detect these pollutants at trace levels in DW. This work describes the first green analytical methodology for multi-class determination of 21 pollutants in DW: seven pesticides, an industrial compound, 12 pharmaceuticals, and a metabolite (some included in Directive 2013/39/EU or Decision 2015/495/EU). A solid-phase extraction procedure followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (offline SPE-UHPLC-MS/MS) method was optimized using eco-friendly solvents, achieving detection limits below 0.20 ng L -1 . The validated analytical method was successfully applied to DW samples from different sources (tap, fountain, and well waters) from different locations in the north of Portugal, as well as before and after bench-scale UV and ozonation experiments in spiked tap water samples. Thirteen compounds were detected, many of them not regulated yet, in the following order of frequency: diclofenac > norfluoxetine > atrazine > simazine > warfarin > metoprolol > alachlor > chlorfenvinphos > trimethoprim > clarithromycin ≈ carbamazepine ≈ PFOS > citalopram. Hazard quotients were also estimated for the quantified substances and suggested no adverse effects to humans. Graphical Abstract Occurrence and removal of multi-class micropollutants in drinking water, analyzed by an eco-friendly LC-MS/MS method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowell, Kevin L.; Slysz, Gordon W.; Baker, Erin Shammel
2013-09-05
We introduce a command line software application LC-IMS-MS Feature Finder that searches for molecular ion signatures in multidimensional liquid chromatography-ion mobility spectrometry-mass spectrometry (LC-IMS-MS) data by clustering deisotoped peaks with similar monoisotopic mass, charge state, LC elution time, and ion mobility drift time values. The software application includes an algorithm for detecting and quantifying co-eluting chemical species, including species that exist in multiple conformations that may have been separated in the IMS dimension.
Exudate Chemical Profiles Derived from Lespedeza and Other Tallgrass Prairie Plant Species
2017-05-01
assayed by liquid chromatography–tandem mass spec- trometry (LC-MS/MS) and gas chromatography/mass spectrometry (GC/MS). The objective was to elucidate...molecular weight compounds were identified via gas chromatography/mass spectrometry (GC/MS) and tentatively identified as benzophenone and 1,4...diacetylbenzene. Three higher molecular weight compounds were identified by liquid chromatography-electrospray ionization- mass spectrometry (LC-ESI-MS
Draisci, Rosa; Palleschi, Luca; Ferretti, Emanuele; Lucentini, Luca; delli Quadri, Fernanda
2003-06-15
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for confirmatory analysis of 17beta-boldenone (17beta-BOL), 17alpha-boldenone (17alpha-BOL) and androsta-1,4-diene-3,17-dione (ADD) in bovine urine was developed. [2H(2)]17beta-Testosterone (17beta-T-d(2)) was used as the internal standard. Sample preparation involved enzymatic hydrolysis and purification on a C(18) solid-phase extraction column. Chromatographic separation of the analytes was obtained using an RP-C(18) HPLC column. LC-MS-MS detection was carried out with an atmospheric pressure chemical ionisation (APCI) source equipped with a heated nebulizer (HN) interface operating in the positive ion mode. For unambiguous hormone confirmation, three analyte precursor-product ion combinations were monitored during multiple-reaction monitoring (MRM) LC-MS-MS analysis. Overall recovery (%), repeatability (relative standard deviations, RSD, %) and within-laboratory reproducibility (RSD, %) ranged from 92.2 to 97.7%, from 6.50 to 2.94% and from 13.50 to 5.04%, respectively, for all analytes. The limit of quantification in bovine urine was 0.20 ng ml(-1) for 17beta-BOL and ADD and 0.50 ng ml(-1) for 17alpha-BOL. The validated method was successfully applied for determination of 17beta-BOL, 17alpha-BOL and ADD in a large number of bovine urine samples collected within the national Official Residue Control Program.
Wang, Ming-Chih; Lai, Yih-Cherng; Chang, Chia-Lin
2008-05-01
Dibenzo[a,c]cyclooctadiene lignans of Schisandra chinensis Baill are well known because of their hepatoprotective activity, antioxidant activity, and anticancer effect. For the isolation of the dibenzo[a,c]cyclooctadiene lignans of Schisandra chinensis Baill two extraction methods were used: modified-ultrasonic extraction and supercritical fluid extraction. A specific and fast analytical method for structure identification is established for quality control because structure elucidation could be accomplished by means of liquid chromatography-mass spectrometry (LC-MS) technologies. The separation and identification of the compounds were completed by: (i) a water-acetonitrile gradient system using a C18 reversed-phase column; (ii) UV detection at 225 nm; (iii) MS/MS experiments with electrospray ionization interface (ESI) ion trap mass spectrometry in the positive mode. Normalized collision energy was used to obtain fragment ions of structural relevance in the LC-MS/MS. These results provided a reliable LC-MS/MS method for the determination of the dibenzo[a,c]cyclooctadiene lignans from Schisandra chinensis Baill. Finally, we also detected 1,1-diphenyl-2-picrylhydrazyl (DPPH) scavenging effects (%) of the modified-ultrasonic and supercritical fluid extracts of Schisandra chinensis Baill compared with 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox). The antioxidant activities of the modified-ultrasonic and supercritical fluid extracts were lower than that of trolox.
Lou, Chaoyan; Wu, Can; Zhang, Kai; Guo, Dandan; Jiang, Lei; Lu, Yang; Zhu, Yan
2018-05-18
Allergenic disperse dyes are a group of environmental contaminants, which are toxic and mutagenic to human beings. In this work, a method of dispersive solid-phase extraction (d-SPE) using graphene-coated polystyrene-divinylbenzene (G@PS-DVB) microspheres coupled with supercritical fluid chromatography (SFC) was proposed for the rapid determination of 10 allergenic disperse dyes in industrial wastewater samples. G@PS-DVB microspheres were synthesized by coating graphene (G) sheets onto polystyrene-divinylbenzene (PS-DVB) polymers. Such novel sorbents were employed in d-SPE for the purification and concentration of allergenic disperse dyes in wastewater samples prior to the determination by SFC with UV detection. To achieve the maximum extraction efficiency for the target dyes, several parameters influencing d-SPE process such as sorbent dosage, extraction time, desorption conditions were investigated. SFC conditions including stationary phase, modifier composition and percentage, column temperature, backpressure and flow rate were optimized to well separate the allergenic disperse dyes. Under the optimum conditions, satisfactory linear relationship (R ≥ 0.9989) was observed with the concentration of dyes ranging from 0.02 to 10.0 μg/mL. The limits of detection (LOD, S/N = 3) for the ten dyes were in the range of 1.1-15.6 ng/mL. Recoveries for the spiked samples were between 89.1% and 99.7% with relative standard deviations (RSD) lower than 10.5% in all cases. The proposed method is time-saving, green, precise and repeatable for the analysis of the target dyes. Furthermore, the application of G@PS-DVB based d-SPE process can be potentially expanded to isolate and concentrate other aromatic compounds in various matrices and supercritical fluid chromatography methodology featuring rapidity, accuracy and green will be an ideal candidate for the analysis of these compounds. Copyright © 2018 Elsevier B.V. All rights reserved.
Prieto-Blanco, M C; Alpendurada, M F; López-Mahía, P; Muniategui-Lorenzo, S; Prada-Rodríguez, D; Machado, S; Gonçalves, C
2012-05-30
Haloacetic acids (HAAs) are organic pollutants originated from the drinking water disinfection process, which ought to be controlled and minimized. In this work a method for monitoring haloacetic acids (HAAs) in water samples is proposed, which can be used in quality control laboratories using the techniques most frequently available. Among its main advantages we may highlight its automated character, including minimal steps of sample preparation, and above all, its improved selectivity and sensitivity in the analysis of real samples. Five haloacetic acids (HAA5) were analyzed using solid-phase extraction (SPE) combined with ion-pair liquid chromatography and tandem mass spectrometry. For the optimization of the chromatographic separation, two amines (triethylamine, TEA and dibutylamine, DBA) as ion pair reagents were compared, and a better selectivity and sensitivity was obtained using DBA, especially for monohaloacetic acids. SPE conditions were optimized using different polymeric adsorbents. The electrospray source parameters were studied for maximum precursor ion accumulation, while the collision cell energy of the triple quadrupole mass spectrometer was adjusted for optimum fragmentation. Precursor ions detected were deprotonated, dimeric and decarboxylated ions. The major product ions formed were: ionized halogen atom (chloride and bromide) and decarboxylated ions. After enrichment of the HAAs in Lichrolut EN adsorbent, the limits of detection obtained by LC-MS/MS analysis (between 0.04 and 0.3 ng mL(-1)) were comparable to those obtained by GC-MS after derivatization. Linearity with good correlation coefficients was obtained over two orders of magnitude irrespective of the compound. Adequate recoveries were achieved (60-102%), and the repeatability and intermediate precision were in the range of 2.4-6.6% and 3.8-14.8%, respectively. In order to demonstrate the usefulness of the method for routine HAAs monitoring, different types of water samples were analyzed. In swimming pool water samples the ∑HAAs were determined between 76 and 154 ng mL(-1). Copyright © 2012 Elsevier B.V. All rights reserved.
Fontana, Ariel R; Bottini, Rubén
2014-05-16
In this work, a reliable, simple, fast, inexpensive and robust sample preparation approach for the determination of multiclass polyphenols in wine samples is proposed. The polyphenols selected for this work were gallic acid, (+)-catechin, (-)-epicatechin, caffeic acid, syringic acid, coumaric acid, ferulic acid, trans-resveratrol, quercetin and cinnamic acid. The method is based on QuEChERS (quick, easy, cheap, effective, rugged and safe) extraction technique coupled with dispersive solid-phase extraction (d-SPE) clean-up. Under optimized conditions, the analytes were extracted from 5mL wine samples (previously acidified with 1% formic acid) using 2.5mL acetonitrile. For phase separation, 1.5g NaCl and 4g anhydrous MgSO4 were added. Then, a 1mL aliquot of the partitioned supernatant was cleaned-up using d-SPE with a combination of 150mg CaCl2, 50mg primary-secondary amine (PSA) and 50mgC18 as sorbents. A 250μL aliquot of the obtained cleaned extract was concentrated to dryness and taken up with the initial mobile phase previous to liquid chromatography-multi-wavelength detection (LC-MWD). The proposed method provided limits of detection (LODs) ranging from 0.004 to 0.079μgmL(-1) and an inter-day variability below 12% RSD for all analytes in red and white wine samples. Considering external calibration (red wines) and matrix-matched calibration (white wines) as quantification techniques, the overall recoveries (accuracy) of the method ranged between 75.0% and 119.6% for red and white wine samples, respectively. The developed method was applied for the determination of polyphenols in 10 wines produced in Argentina. Nine phenolic compounds were determined, at concentrations above detectable levels in the method. The maximum concentrations corresponded to (-)-epicatechin in white wines, while gallic acid and (+)-catechin were the most abundant in red wines. Copyright © 2014 Elsevier B.V. All rights reserved.
SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine.
Kubota, Ryuichi; Endo, Yoko; Takeuchi, Akito; Inoue, Yoshinori; Ogata, Hiroko; Ogawa, Masanori; Nakagawa, Tomoo; Onda, Nobuhiko; Endo, Ginji
2007-07-01
An analytical method using a combination of solid-phase extraction (SPE) and gas chromatography with a flame thermionic detector (GC/FTD) was developed for determination of N-methyl-2-pyrrolidone (NMP), N-methylsuccinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) in human urine. The SPE cartridge of poly(divinylbenzene/hydroxymethacrylate) used was directly loaded with urine sample, followed by elution with methyl isobutyl ketone (MIBK) and subsequent centrifugation, and the supernatant was injected into the capillary GC using a DB1701. This method allowed efficient separation of NMP, MSI, and 2-HMSI, which were nearly free of interference by other GC peaks arising from urine. Recoveries of NMP, MSI, and 2-HMSI from the SPE cartridge were about 98, 101, and 67%, respectively, with limits of detection of 0.04, 0.02, and 0.06 mg/L, respectively, which met the regulatory requirements. The present method was used for assay in biological monitoring of workers exposed to NMP in their occupational environment.
Kamberi, Marika; Tran, Thu-Ngoc
2012-11-01
High-throughput 96-well solid phase extraction (SPE) plate with C-18 reversed phase sorbent followed by UV-visible (UV-Vis) microplate reader was applied to the analysis of hydrophobic drugs in surfactant-containing dissolution media, which are often used to evaluate the in-vitro drug release of drug eluting stents (DES). Everolimus and dissolution medium containing Triton X-405 were selected as representatives, and the appropriate SPE conditions (adsorption, washing and elution) were investigated to obtain a practical and reliable sample clean-up. It was shown that the developed SPE procedure was capable of removing interfering components (Triton X-405 and its impurities), allowing for an accurate automated spectrophotometric analysis to be performed. The proposed UV-Vis spectrophotometric method yielded equivalent results compared to a classical LC analysis method. Linear regression analysis indicated that both methods have the ability to obtain test results that are directly proportional to the concentration of analyte in the sample within the selected range of 1.0-10 μg/ml for everolimus, with a coefficient of correlation (r(2)) value of >0.998 and standard deviation of the residuals (Syx) of <2%. The individual recoveries of everolimus ranged from 97 to 104% for the UV-Vis spectrophotometric method and from 98 to 102 for the HPLC method, respectively. The 95% CI of the mean recovery for the UV-Vis spectrophotometric method was 99-102% and for the HPLC method was 99-101%. No statistical difference was found between the mean recoveries of the methods (p=0.42). Hence the methods are free from interference due to Triton and other chemicals present in the dissolution medium. The variation in the amount of everolimus estimated by UV-Vis spectrophotometric and HPLC methods was ≤3.5%, and the drug release profiles obtained by both methods were found to be equivalent by evaluation with two-one-sided t-test (two-tailed, p=0.62; mean of differences, 0.17; 95% CI, 0.62-0.96) and similarity factor f2 (f2 value, 87). The excellent conformity of the results makes UV-Vis spectrophotometer an ideal tool for analyzing the drugs in the media containing surfactants, after SPE. The 96-well SPE plates in combination with UV-Vis microplate reader provide a high throughput method for the determination of in-vitro drug release profile of DES. Switching from HPLC to UV-Vis spectrophotometer microplate reader assay reduces the solvent consumption and labor required for the sample analyses. This directly impacts the profitability of the laboratory. Copyright © 2012 Elsevier B.V. All rights reserved.
Crowell, Kevin L; Slysz, Gordon W; Baker, Erin S; LaMarche, Brian L; Monroe, Matthew E; Ibrahim, Yehia M; Payne, Samuel H; Anderson, Gordon A; Smith, Richard D
2013-11-01
The addition of ion mobility spectrometry to liquid chromatography-mass spectrometry experiments requires new, or updated, software tools to facilitate data processing. We introduce a command line software application LC-IMS-MS Feature Finder that searches for molecular ion signatures in multidimensional liquid chromatography-ion mobility spectrometry-mass spectrometry (LC-IMS-MS) data by clustering deisotoped peaks with similar monoisotopic mass, charge state, LC elution time and ion mobility drift time values. The software application includes an algorithm for detecting and quantifying co-eluting chemical species, including species that exist in multiple conformations that may have been separated in the IMS dimension. LC-IMS-MS Feature Finder is available as a command-line tool for download at http://omics.pnl.gov/software/LC-IMS-MS_Feature_Finder.php. The Microsoft.NET Framework 4.0 is required to run the software. All other dependencies are included with the software package. Usage of this software is limited to non-profit research to use (see README). rds@pnnl.gov. Supplementary data are available at Bioinformatics online.
This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.
USDA-ARS?s Scientific Manuscript database
A liquid chromatography-mass spectrometry (LC/MS) method for simultaneous quantitation of seven ergot alkaloids (lysergic acid, ergonovine, ergovaline, ergocornine, ergotamine, ergocryptine and ergocrystine) in vascular tissue was developed and validated. Reverse-phase chromatography, coupled to an...
Metz, Thomas O.; Zhang, Qibin; Page, Jason S.; Shen, Yufeng; Callister, Stephen J.; Jacobs, Jon M.; Smith, Richard D.
2008-01-01
SUMMARY The future utility of liquid chromatography-mass spectrometry (LC-MS) in metabolic profiling and metabolomic studies for biomarker discover will be discussed, beginning with a brief description of the evolution of metabolomics and the utilization of the three most popular analytical platforms in such studies: NMR, GC-MS, and LC-MS. Emphasis is placed on recent developments in high-efficiency LC separations, sensitive electrospray ionization approaches, and the benefits to incorporating both in LC-MS-based approaches. The advantages and disadvantages of various quantitative approaches are reviewed, followed by the current LC-MS-based tools available for candidate biomarker characterization and identification. Finally, a brief prediction on the future path of LC-MS-based methods in metabolic profiling and metabolomic studies is given. PMID:19177179
Lipid Informed Quantitation and Identification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kevin Crowell, PNNL
2014-07-21
LIQUID (Lipid Informed Quantitation and Identification) is a software program that has been developed to enable users to conduct both informed and high-throughput global liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based lipidomics analysis. This newly designed desktop application can quickly identify and quantify lipids from LC-MS/MS datasets while providing a friendly graphical user interface for users to fully explore the data. Informed data analysis simply involves the user specifying an electrospray ionization mode, lipid common name (i.e. PE(16:0/18:2)), and associated charge carrier. A stemplot of the isotopic profile and a line plot of the extracted ion chromatogram are also provided to showmore » the MS-level evidence of the identified lipid. In addition to plots, other information such as intensity, mass measurement error, and elution time are also provided. Typically, a global analysis for 15,000 lipid targets« less
High Resolution Separations and Improved Ion Production and Transmission in Metabolomics
Metz, Thomas O.; Page, Jason S.; Baker, Erin S.; Tang, Keqi; Ding, Jie; Shen, Yufeng; Smith, Richard D.
2008-01-01
The goal of metabolomics analyses is the detection and quantitation of as many sample components as reasonably possible in order to identify compounds or “features” that can be used to characterize the samples under study. When utilizing electrospray ionization to produce ions for analysis by mass spectrometry (MS), it is important that metabolome sample constituents be efficiently separated prior to ion production, in order to minimize ionization suppression and thereby extend the dynamic range of the measurement, as well as the coverage of the metabolome. Similarly, optimization of the MS inlet and interface can lead to increased measurement sensitivity. This perspective review will focus on the role of high resolution liquid chromatography (LC) separations in conjunction with improved ion production and transmission for LC-MS-based metabolomics. Additional emphasis will be placed on the compromise between metabolome coverage and sample analysis throughput. PMID:19255623
Stanfill, S B; Ashley, D L
2000-04-01
Little is known about the possible health effects associated with inhaling alkenylbenzenes through cigarette smoking, even though these flavor-related compounds have known toxic effects in animals. We developed a rapid and sensitive solid-phase extraction (SPE) method to quantify seven alkenylbenzenes and piperonal in mainstream cigarette smoke particulate. The smoke particulate fraction of a single cigarette was collected on Cambridge filter pads, solvent extracted, concentrated, purified with SPE, and analyzed by selected ion monitoring gas chromatography-mass spectrometry. We positively identified and quantified five alkenylbenzenes compounds (eugenol, isoeugenol, methyleugenol myristicin, and elemicin) and piperonal in the smoke particulate from eight U.S. brands with mean levels (measured in triplicate) ranging from 6.6 to 4210 ng per cigarette. Additionally, complete blocking of nearly invisible ventilation holes in the cigarette filter increased 2- to 7-fold the percent transfer of alkenylbenzenes from tobacco to the particulate fraction of mainstream smoke.
Willemse, Chandré M; Stander, Maria A; Vestner, Jochen; Tredoux, Andreas G J; de Villiers, André
2015-12-15
Changes in anthocyanin chemistry represent some of the most important transformations involved in red wine aging. However, accurate analysis of the derived pigments, as required to study the evolution of anthocyanins and tannins during aging, is hampered by their extreme structural diversity, low levels, and the fact that many of these compounds have identical mass spectral characteristics. In this context, chromatographic separation is critical. In this contribution, the application of online hydrophilic interaction chromatography (HILIC) × reversed-phase liquid chromatography (RP-LC) separation coupled to high-resolution mass spectrometry (MS) is described for the detailed characterization of anthocyanins and their derived pigments in aged red wine. A systematic approach was followed for the optimization of HILIC × RP-LC separation parameters using a capillary liquid chromatography (LC) system in the first dimension and an ultrahigh-pressure LC system in the second dimension to ensure maximum sensitivity and performance. Ninety four (94) anthocyanin-derived pigments were tentatively identified in one- and six-year-old Pinotage wines using accurate mass and fragmentation information obtained using quadrupole-time-of-flight mass spectrometry (Q-TOF-MS). Online HILIC × RP-LC-MS was found to offer high-resolution separation, because of the combination of two different separation modes, while the structured elution order observed improved the certainty in compound identification. Therefore, this approach shows promise for the detailed elucidation of the chemical alteration of anthocyanins during wine aging.
Toledano, R M; Díaz-Plaza, E M; Cortes, J M; Aragón, A; Vázquez, A M; Villén, J; Muñoz-Guerra, J
2014-11-28
Boldenone (Bo), androsta-1,4-dien-17β-ol-3-one, is an anabolic androgenic steroid not clinically approved for human application. Despite this, many cases are reported every year of athletes testing positive for Bo or its main metabolite 5β-androst-1-en-17β-ol-3-one (BoM). Recently the capability of different human intestinal bacteria to produce enzymes able to modify endogenous steroids in Bo has been demonstrated. When a urinary concentration of Bo and/or BoM between 5 and 30 ng/mL is measured a complementary analysis by gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) must be carried out to discriminate the endogenous or exogenous origin. In the present work, a novel analytical method that couples LC-GC by means of the TOTAD interface with C-IRMS is described. The method is based on a first RPLC separation of unacetyled steroids, followed by acetylation and automated on-line LC-GC-C-IRMS, which includes a second RPLC clean-up of acetyl Bo and BoM, isolation of the two fractions in a fraction collector and their consecutive analysis by GC-C-IRMS. The method has been applied to the analysis of urine samples fortified at 5 and 10 ng/mL, where it has shown a good performance. Copyright © 2014 Elsevier B.V. All rights reserved.
Mikami, Eiichi; Ohno, Tsutomu; Matsumoto, Hiroshi
2002-12-04
An easily available, simultaneous identification/determination procedure for phentolamine (PHE) and sildenafil (SIL) in adulterated dietary supplements was established by using a combination of three different analytical methods; thin-layer chromatography (TLC), liquid chromatography-mass spectrometry (LC/MS) and a high-performance liquid chromatography (HPLC)/photo-diode-array. The sample solution for TLC was applied to silica gel 60 F(254) plates with chloroform/ammonia solution (28)/methanol (70:5:3, lower layer) and chloroform/diethylamine/methanol (15:3:2) as the developing solvent. Spots were located under UV radiation at 254 nm. Mass spectra of PHE and SIL by LC/MS were investigated with electrospray ionization (ESI) interface, under both positive and negative ion mode. The HPLC analysis was performed on a column of Wakosil 5C18 (4.6 mm x 150 mm, 5 microm) with water/methanol/acetonitrile/triethylamine (580:250:170:1) adjusted with phosphoric acid to pH 3.0 as the mobile phase, and the effluent was monitored with a photo-diode-array detector. Quantitative HPLC analysis of PHE and SIL were detected at 280 nm. When this procedure was applied to commercial soft drinks, PHE and SIL were identified and determined at a concentration of 17 mg PHE and 44 mg SIL per bottle, respectively. The procedure described here is available for the screening of PHE and SIL in adulterated supplements. Copyright 2002 Elsevier Science Ireland Ltd.
What is the study?
An invited review article. Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)
Why was it done?
Although oxidative stress is frequently cited as a cause of various adverse biological eff...
This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.
Method MS014 describes procedures for solvent extraction of aldicarb, bromadiolone, carbofuran, oxamyl and methomyl from water samples, followed by analysis using liquid chromatography tandem mass spectrometry (LC-MS-MS).
Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...
Kim, Da-Hye; Oh, Jeong-Eun
2017-05-01
Human hair has many advantages as a non-invasive sample; however, analytical methods for detecting perfluoroalkyl substances (PFASs) in human hair are still in the development stage. Therefore, the aim of this study was to develop and validate a method for monitoring 11 PFASs in human hair. Solid-phase extraction (SPE), ion-pairing extraction (IPE), a combined method (SPE+IPE) and solvent extraction with ENVI-carb clean-up were compared to develop an optimal extraction method using two types of hair sample (powder and piece forms). Analysis of PFASs was performed using liquid chromatography and tandem mass spectrometry. Among the four different extraction procedures, the SPE method using powdered hair showed the best extraction efficiency and recoveries ranged from 85.8 to 102%. The method detection limits for the SPE method were 0.114-0.796 ng/g and good precision (below 10%) and accuracy (66.4-110%) were obtained. In light of these results, SPE is considered the optimal method for PFAS extraction from hair. It was also successfully used to detect PFASs in human hair samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
On-line MSPD-SPE-HPLC/FLD analysis of polycyclic aromatic hydrocarbons in bovine tissues.
Gutiérrez-Valencia, Tania M; García de Llasera, Martha P
2017-05-15
A fast method was optimized and validated for simultaneous trace determination of four polycyclic aromatic hydrocarbons: benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene in bovine tissues. The determination was performed by matrix solid-phase dispersion (MSPD) coupled on-line to solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with fluorescence detection (FLD). The sample was dispersed on C 18 silica sorbent and then the on-line MSPD-SPE-HPLC/FLD method was applied. Several parameters were optimized: cleaning and elution sequences applied to the MSPD cartridge, the flow rate and dilution of extract used for SPE loading. The on-line method was validated over a concentration range of 0.1-0.6ngg -1 obtaining good linearity (r⩾0.998) and precision (RSD)⩽10%. Recovery ranged from 96 to 99% and the limits of detection were 0.012ngg -1 . This methodology was applied to liver samples from unhealthy animals. The results demonstrate that MSDP-SPE-HPLC/FLD method provides reliable, sensitive, accurate and fast data to the food control. Copyright © 2016 Elsevier Ltd. All rights reserved.
Isolation and pharmacological characterization of fatty acids from saw palmetto extract.
Abe, Masayuki; Ito, Yoshihiko; Suzuki, Asahi; Onoue, Satomi; Noguchi, Hiroshi; Yamada, Shizuo
2009-04-01
Saw palmetto extract (SPE) has been widely used for the treatment of lower urinary-tract symptoms secondary to benign prostatic hyperplasia. The mechanisms of pharmacological effects of SPE include the inhibition of 5alpha-reductase, anti-androgenic effects, anti-proliferative effects, and anti-inflammatory effects. Previously, we showed that SPE bound actively to alpha(1)-adrenergic, muscarinic and 1,4-dihydropyridine calcium channel (1,4-DHP) receptors in the prostate and bladder of rats, whereas its active constituents have not been fully clarified. The present investigation is aimed to identify the main active components contained in hexane and diethyl ether extracts of SPE with the use of column chromatography and preparative HPLC. Based on the binding activity with alpha(1)-adrenergic, muscarinic, and 1,4-DHP receptors, both isolated oleic and lauric acids were deduced to be active components. Authentic samples of oleic and lauric acids also exhibited similar binding activities to these receptors as the fatty acids isolated from SPE, consistent with our findings. In addition, oleic and lauric acids inhibited 5alpha-reductase, possibly leading to therapeutic effects against benign prostatic hyperplasia and related lower urinary-tract symptoms.
Kuuranne, Tiia; Thomas, Andreas; Leinonen, Antti; Delahaut, Philippe; Bosseloir, Alan; Schänzer, Wilhelm; Thevis, Mario
2008-01-01
Insulin is a peptide hormone consisting of two peptide chains (A- and B-chain) that are cross-linked by two disulfide bonds. To obtain improved pharmacokinetic onset of action profiles of insulin treatment in diabetic patients, recombinant long-, intermediate-, and rapid-acting insulin analogs are produced, in which the C-terminal end of the B-chain plays an especially important role.A review of the veterinary literature reveals the low prevalence of equine type I diabetes mellitus, which indicates that the therapeutic use of insulin in racing horses is unlikely. Although there is no unequivocal evidence of an overall performance-enhancing effect of insulin, in human sports the misuse of insulin preparations is reported among elite athletes. The desired effects of insulin include the increase of muscular glycogen prior to sports event or during the recovery phase, in addition to a chalonic action, which increases the muscle size by inhibiting protein breakdown. In the present study urinary insulin was detected in equine samples and differences between equine insulin, human insulin, as well as rapidly acting recombinant insulin variants were examined. The method was based on sample purification by solid-phase extraction (SPE) and immunoaffinity chromatography (IAC), and subsequent analysis by microbore liquid chromatography (LC) and tandem mass spectrometry (MS/MS) using top-down sequencing for the determination of various insulins. Product ion scan experiments of intact proteins and B-chains enabled the differentiation between endogenously produced equine insulin, its DesB30 metabolite, human insulin and recombinant insulin analogs, and the assay allowed the assignment of individual product ions, especially those originating from modified C-termini of B-chains. Copyright (c) 2008 John Wiley & Sons, Ltd.
Lu, Dasheng; Jin, Yu'e; Feng, Chao; Wang, Dongli; Lin, Yuanjie; Qiu, Xinlei; Xu, Qian; Wen, Yimin; She, Jianwen; Wang, Guoquan; Zhou, Zhijun
2017-09-01
Commonly, analytical methods measuring brominated flame retardants (BFRs) of different chemical polarities in human serum are labor consuming and tedious. Our study used acidified diatomaceous earth as solid-phase extraction (SPE) adsorbent and defatting material to simultaneously determine the most abundant BFRs and their metabolites with different polarities in human serum samples. The analytes include three types of commercial BFRs, tetrabromobisphenol A (TBBPA), hexabromocyclododecane (HBCD) isomers, and polybrominated biphenyl ethers (PBDEs), and dominant hydroxylated BDE (OH-PBDE) and methoxylated BDE (MeO-PBDE) metabolites of PBDEs. The sample eluents were sequentially analyzed for PBDEs and MeO-BDEs on online gel permeation chromatography/gas chromatography-electron capture-negative ionization mass spectrometry (online GPC GC-ECNI-MS) and for TBBPA, HBCD, and OH-BDEs on liquid chromatography-tandem mass spectrometry (LC-MS/MS). Method recoveries were 67-134% with a relative standard deviation (RSD) of less than 20%. Method detection limits (MDLs) were 0.30-4.20 pg/mL fresh weight (f.w.) for all analytes, except for BDE-209 of 16 pg/mL f.w. The methodology was also applied in a pilot study, which analyzed ten real samples from healthy donors in China, and the majority of target analytes were detected with a detection rate of more than 80%. To our knowledge, it is the first time for us in effectively determining BFRs of most types in one aliquot of human serum samples. This new analytical method is more specific, sensitive, accurate, and time saving for routine biomonitoring of these BFRs and for integrated assessment of health risk of BFR exposure.
Gilbert-López, Bienvenida; García-Reyes, Juan F; Meyer, Cordula; Michels, Antje; Franzke, Joachim; Molina-Díaz, Antonio; Hayen, Heiko
2012-11-21
A Dielectric Barrier Discharge Ionization (DBDI) LC/MS interface is based on the use of a low-temperature helium plasma, which features the possibility of simultaneous ionization of species with a wide variety of physicochemical properties. In this work, the performance of LC/DBDI-MS for trace analysis of highly relevant species in food and environment has been examined. Over 75 relevant species including multiclass priority organic contaminants and residues such as pesticides, polycyclic aromatic hydrocarbons, organochlorine species, pharmaceuticals, personal care products, and drugs of abuse were tested. LC/DBDI-MS performance for this application was assessed and compared with standard LC/MS sources (electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI)). The used benchtop Orbitrap mass spectrometer features a 10 Hz polarity switching mode, so that both positive and negative ion mode acquisitions are possible with acquisition cycles matching the requirements of fast liquid chromatography. Both polar and nonpolar species (including those typically analyzed by GC/electron ionization-MS) can be tested in a single run using polarity switching mode. The methodology was found to be effective in detecting a wide array of organic compounds at concentration levels in the low ng L(-1) to μg kg(-1) range in wastewater and food matrices, respectively. The linearity was evaluated in an olive oil extract, obtaining good correlation coefficients in the studied range. Additionally, minor matrix effects (≤15% of signal suppression or enhancement) were observed for most of the studied analytes in this complex fatty matrix. The results obtained were compared with data from both ESI and APCI sources, obtaining a merged coverage between ESI and APCI in terms of analyte ionization and higher overall sensitivity for the proposed ion source based on the DBD principle. The use of this approach further extends the coverage of current LC/MS methods towards an even larger variety of chemical species including both polar and nonpolar (non-ESI amenable) species and may find several applications in fields such as food and environment testing or metabolomics where GC/MS and LC/MS are combined to cover as many different species as possible.
Fayad, Paul B; Roy-Lachapelle, Audrey; Duy, Sung Vo; Prévost, Michèle; Sauvé, Sébastien
2015-12-15
An analytical method based on on-line SPE-LC-HESI-MS/MS has been developed for the detection and quantification of eight selected cyanotoxins in algal bloom waters that include mycrocystins, anatoxin-a and cylindrospermopsin. The injection volume was 2 mL according to the expected concentration of cyanotoxins in matrix. The method provides an analysis time of 7 min per sample, acceptable recovery values (91-101%), good precision (RSD < 13%) and method limits of detection at the sub-microgram per liter levels (0.01-0.02 μg L(-1)). A detailed discussion on optimization parameters that have an impact on the overall performance of the method are presented. In particular, method optimization permitted the chromatographic separation of anatoxin-a and phenylalanine, an isobaric interference with a similar chromatographic characteristics. All optimization and validation experiments for the on-line SPE method and chromatographic separation were performed in environmentally relevant algal bloom water matrices. The applicability of the method was tested on several algal bloom water samples from monitored lakes across the province of Québec (Québec, Canada) known to produce cyanotoxins. All of the targeted cyanotoxins were detected with the exception of cylindrospermopsin. In addition, it was found that total microcystin concentrations in several surface water samples exceeded the proposed guidelines established by the province of Québec in Canada of 1.5 μg L(-1) as well as the World Health Organization of 1 μg L(-1) for both free and cell-bound microcystin-LR equivalent. Copyright © 2015 Elsevier Ltd. All rights reserved.
Khan, Kashif M; Nahar, Lutfun; Al-Groshi, Afaf; Zavoianu, Alexandra G; Evans, Andrew; Dempster, Nicola M; Wansi, Jean D; Ismail, Fyaz M D; Mannan, Abdul; Sarker, Satyajit D
2016-10-01
Trillium govanianum Wall. (Melanthiaceae alt. Trilliaceae), commonly known as 'nag chhatri' or 'teen patra', is a native species of the Himalayas. It is used in various traditional medicines containing both steroids and sex hormones. In folk medicine, the rhizomes of T. govanianum are used to treat boils, dysentery, inflammation, menstrual and sexual disorders, as an antiseptic and in wound healing. With the only exception of the recent report on the isolation of a new steroidal saponin, govanoside A, together with three known steroidal compounds with antifungal property from this plant, there has been no systematic pharmacological and phytochemical work performed on T. govanianum. This paper reports, for the first time, on the cytotoxicity of the methanol extract of the roots of T. govanianum and its solid-phase extraction (SPE) fractions against four human carcinoma cell lines: breast (MCF7), liver (HEPG2), lung (A549) and urinary bladder (EJ138), using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide cytotoxicity assay and liquid chromatography and electrospray ionization quadrupole time-of-flight mass spectrometry analysis of the SPE fractions. The methanol extract and all SPE fractions exhibited considerable levels of cytotoxicity against all cell lines, with the IC 50 values ranging between 5 and 16 µg/mL. Like other Trillium species, presence of saponins and sapogenins in the SPE fractions was evident in the liquid chromatography mass spectrometry data. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Moerdijk-Poortvliet, Tanja C W; Schierbeek, Henk; Houtekamer, Marco; van Engeland, Tom; Derrien, Delphine; Stal, Lucas J; Boschker, Henricus T S
2015-07-15
We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although LC/IRMS is expected to be more accurate and precise, no direct comparison has been reported. GC/IRMS with the aldonitrile penta-acetate (ANPA) derivatisation method was compared with LC/IRMS without derivatisation. A large number of glucose standards and a variety of natural samples were analysed for five neutral carbohydrates at natural abundance as well as at (13)C-enriched levels. Gas chromatography/chemical ionisation mass spectrometry (GC/CIMS) was applied to check for incomplete derivatisation of the carbohydrate, which would impair the accuracy of the GC/IRMS method. The LC/IRMS technique provided excellent precision (±0.08‰ and ±3.1‰ at natural abundance and enrichment levels, respectively) for the glucose standards and this technique proved to be superior to GC/IRMS (±0.62‰ and ±19.8‰ at natural abundance and enrichment levels, respectively). For GC/IRMS measurements the derivatisation correction and the conversion of carbohydrates into CO2 had a considerable effect on the measured δ(13)C values. However, we did not find any significant differences in the accuracy of the two techniques over the full range of natural δ(13)C abundances and (13)C-labelled glucose. The difference in the performance of GC/IRMS and LC/IRMS diminished when the δ(13)C values were measured in natural samples, because the chromatographic performance and background correction became critical factors, particularly for LC/IRMS. The derivatisation of carbohydrates for the GC/IRMS method was complete. Although both LC/IRMS and GC/IRMS are reliable techniques for compound-specific stable carbon isotope analysis of carbohydrates (provided that derivatisation is complete and the calibration requirements are met), LC/IRMS is the technique of choice. The reasons for this are the improved precision, simpler sample preparation, and straightforward isotopic calibration. Copyright © 2015 John Wiley & Sons, Ltd.
Crepier, Julien; Le Masle, Agnès; Charon, Nadège; Albrieux, Florian; Duchene, Pascal; Heinisch, Sabine
2018-06-01
Extensive characterization of complex mixtures requires the combination of powerful analytical techniques. A Supercritical Fluid Chromatography (SFC) method was previously developed, for the specific case of fast pyrolysis bio oils, as an alternative to gas chromatography (GC and GC × GC) or liquid chromatography (LC and LC × LC), both separation methods being generally used prior to mass spectrometry (MS) for the characterization of such complex matrices. In this study we investigated the potential of SFC hyphenated to high resolution mass spectrometry (SFC-HRMS) for this characterization using Negative ion Atmospheric Pressure Chemical ionization ((-)APCI) for the ionization source. The interface between SFC and (-)APCI/HRMS was optimized from a mix of model compounds with the objective of maximizing the signal to noise ratio. The main studied parameters included both make-up flow-rate and make-up composition. A methodology for the treatment of APCI/HRMS data is proposed. This latter allowed for the identification of molecular formulae. Both SFC-APCI/HRMS method and data processing method were applied to a mixture of 36 model compounds, first analyzed alone and then spiked in a bio-oil. In both cases, 19 compounds could be detected. Among them 9 could be detected in a fast pyrolysis bio-oil by targeted analysis. The whole procedure was applied to the characterization of a bio-oil using helpful representations such as mass-plots, van Krevelen diagrams and heteroatom class distributions. Finally the results were compared with those obtained with a Fourier Transform ion-cyclotron resonance mass spectrometer (FT-ICR/MS). Copyright © 2018 Elsevier B.V. All rights reserved.
Quigley, W W; Ecker, S T; Vahey, P G; Synovec, R E
1999-10-01
The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m(-1), was obtained for resorcinol, at a retention factor of k'=4.88 (retention time of 9.55 min at 1 ml min(-1) for a 25 cmx4.6 mm i.d. column, packed with 5 mum diameter particles with the cyano propyl stationary phase). A separation via reversed phase liquid chromatography (RP-LC) with a 100% water mobile phase of six phenols and related compounds was compared to a separation of the same compounds by traditional RP-LC, using octadecylsilane (ODS), i.e. C18, bound to silica and an aqueous mobile phase modified with acetonitrile. Nearly identical analysis time was achieved for the separation of six phenols and related compounds using the cyano propyl stationary phase with a 100% water mobile phase, as compared to traditional RP-LC requiring a relatively large fraction of organic solvent modifier in the mobile phase (25% acetonitrile:75% water). Additional understanding of the retention mechanism with the 100% water mobile phase was obtained by relating measured retention factors of aliphatic alcohols, phenols and related compounds, and chlorinated hydrocarbons to their octanol:water partition coefficients. The retention mechanism is found to be consistent with a RP-LC mechanism coupled with an additional retention effect due to residual hydroxyl groups on the cyano propyl stationary phase. Advantages due to a 100% water mobile phase for the chemical analysis of alcohol mixtures and chlorinated hydrocarbons are reported. By placing an absorbance detector in-series and preceding a novel drop interface to a flame ionization detector (FID), selective detection of a separated mixture of phenols and related compounds and aliphatic alcohols is achieved. The compound class of aliphatic alcohols is selectively and sensitively detected by the drop interface/FID, and the phenols and related compounds are selectively and sensitively detected by absorbance detection at 200 nm. The separation and detection of chlorinated hydrocarbons in a water sample matrix further illustrated the advantages of this methodology. The sensitivity and selectivity of the FID signal for the chlorinated hydrocarbons are significantly better than absorbance detection, even at 200 nm. This methodology is well suited to continuous and automated monitoring of water samples. The applicability of samples initially in an organic solvent matrix is explored, since an organic sample matrix may effect retention and efficiency. Separations in acetonitrile and isopropyl alcohol sample matrices compared well to separations with a water sample matrix.
Küster, Simon K; Pabst, Martin; Jefimovs, Konstantins; Zenobi, Renato; Dittrich, Petra S
2014-05-20
We present a robust droplet-based device, which enables the fractionation of ultralow flow rate nanoflow liquid chromatography (nano-LC) eluate streams at high frequencies and high peak resolution. This is achieved by directly interfacing the separation column to a micro T-junction, where the eluate stream is compartmentalized into picoliter droplets. This immediate compartmentalization prevents peak dispersion during eluate transport and conserves the chromatographic performance. Subsequently, nanoliter eluate fractions are collected at a rate of one fraction per second on a high-density microarray to retain the separation with high temporal resolution. Chromatographic separations of up to 45 min runtime can thus be archived on a single microarray possessing 2700 sample spots. The performance of this device is demonstrated by fractionating the separation of a tryptic digest of a known protein mixture onto the microarray chip and subsequently analyzing the sample archive using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Resulting peak widths are found to be significantly reduced compared to standard continuous flow spotting technologies as well as in comparison to a conventional nano-LC-electrospray ionization-mass spectrometry interface. Moreover, we demonstrate the advantage of our high-definition nanofractionation device by applying two different MALDI matrices to all collected fractions in an alternating fashion. Since the information that is obtained from a MALDI-MS measurement depends on the choice of MALDI matrix, we can extract complementary information from neighboring spots containing almost identical composition but different matrices.
MacMahon, Shaun; Mazzola, Eugene; Begley, Timothy H; Diachenko, Gregory W
2013-05-22
A new analytical method has been developed and validated for the detection of glycidyl esters (GEs) and 3-monochloropropanediol (3-MCPD) monoesters in edible oils. The target compounds represent two classes of potentially carcinogenic chemical contaminants formed during the processing of edible oils. Target analytes are separated from edible oil matrices using a two-step solid-phase extraction (SPE) procedure. The extracts are then analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). Chromatographic conditions that separate sn-1 and sn-2 monoesters of 3-MCPD have been developed for the first time. The method has been validated for GEs, sn-1 3-MCPD monoesters of lauric, myristic, linolenic, linoleic, oleic, and stearic acids, and sn-2 3-MCPD monoesters of oleic and palmitic acids in coconut, olive, and palm oils using an external calibration curve. The range of average recoveries and relative standard deviations (RSDs) across the three oil matrices at three spiking concentrations are 84-115% (3-16% RSD) for the GEs, 95-113% (1-10% RSD) for the sn-1 3-MCPD monoesters, and 76.8-103% (5.1-11.2% RSD) for the sn-2 3-MCPD monoesters, with limits of quantitation at or below 30 ng/g for the GEs, 60 ng/g for sn-1 3-MCPD monoesters, and 180 ng/g for sn-2 3-MCPD monoesters.
Suh, Joon Hyuk; Niu, Yue S; Hung, Wei-Lun; Ho, Chi-Tang; Wang, Yu
2017-06-01
Lipid peroxidation gives rise to carbonyl species, some of which are reactive and play a role in the pathogenesis of numerous human diseases. Oils are ubiquitous sources that can be easily oxidized to generate these compounds under oxidative stress. In this present work, we developed a targeted lipidomic method for the simultaneous determination of thirty-five aldehydes and ketones derived from fish oil, the omega-3 fatty acid-rich source, by using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analytes include highly toxic reactive carbonyl species (RCS) such as acrolein, crotonaldehyde, trans-4-hydroxy-2-hexenal (HHE), trans-4-hydroxy-2-nonenal (HNE), trans-4-oxo-2-nonenal (ONE), glyoxal and methylglyoxal, all of which are promising biomarkers of lipid peroxidation. They were formed using in vitro Fe(II)-mediated oxidation, and derivatized using 2,4-dinitrophenylhydrazine (DNPH) for the feasibility of quantitative assay. Before analysis, solid phase extraction (SPE) was used to clean samples further. Uniquely different patterns of carbonyl compound generation between omega-3 and 6 fatty acids were observed using this lipidomic approach. The method developed was both validated, and successfully applied to monitor formation of carbonyl species by lipid peroxidation using ten different fish oil products. Hypotheses of correlations between the monitored dataset of analytes and their parent fatty acids were also tested using the Pearson's correlation test. Results indicate our method is a useful analytical tool for lipid peroxidation studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Picó, Yolanda; Alvarez-Ruiz, Rodrigo; Wijaya, Leonard; Alfarhan, Ahmed; Alyemeni, Mohammed; Barceló, Damià
2018-01-01
A liquid chromatography quadruple time-of-flight mass spectrometry (LC-QqTOF-MS/MS) method was developed for simultaneous quantitative analysis of ibuprofen (IBU), 1- and 2-hydroxyibuprofen (1-OH IBU and 2-OH IBU), and carboxyibuprofen (CBX IBU) while preserving the ability of the instrument to get precursor and product ion mass spectra of non-target compounds. The trigger was the precursor ions reaching 100 cps intensity. Sample preparation was carried out by ultrasound solid-liquid extraction with methanol as extraction solvent at pH < 2 followed by solid-phase extraction (SPE) clean-up using STRATA-X cartridges and methanol as an eluent. Linearity was obtained in the range 50-10,000 ng mL -1 for IBU, each OH IBU and CBX IBU (r ≥ 0.99). The proposed method was satisfactorily validated showing absolute recoveries of > 70% for all target analytes at low and high concentration levels. The lowest limit of quantification was < 50 ng g -1 in plant. This method was applied to investigate IBP behavior in cowpea (Vigna unguiculata (L.) Walp) treated at high IBU concentrations and its presence in vegetables irrigated with treated water. Up to 46 metabolites, mostly hydroxylated metabolites and conjugates with hexosides and amino acids, were identified. The most abundant metabolites were also identified in an eggplant sample. Graphical Abstract ᅟ Ibuprofen metabolite identification.
Martins, Magda Targa; Melo, Jéssica; Barreto, Fabiano; Hoff, Rodrigo Barcellos; Jank, Louise; Bittencourt, Michele Soares; Arsand, Juliana Bazzan; Schapoval, Elfrides Eva Scherman
2014-11-01
In routine laboratory work, screening methods for multiclass analysis can process a large number of samples in a short time. The main challenge is to develop a methodology to detect as many different classes of residues as possible, combined with speed and low cost. An efficient technique for the analysis of multiclass antibacterial residues (fluoroquinolones, tetracyclines, sulfonamides and trimethoprim) was developed based on simple, environment-friendly extraction for bovine milk, cattle and poultry liver. Acidified ethanol was used as an extracting solvent for milk samples. Liver samples were treated using EDTA-washed sand for cell disruption, methanol:water and acidified acetonitrile as extracting solvent. A total of 24 antibacterial residues were detected and confirmed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), at levels between 10, 25 and 50% of the maximum residue limit (MRL). For liver samples a metabolite (sulfaquinoxaline-OH) was also monitored. A validation procedure was conducted for screening purposes in accordance with European Union requirements (2002/657/EC). The detection capability (CCβ) false compliant rate was less than 5% at the lowest level for each residue. Specificity and ruggedness were also discussed. Incurred and routine samples were analyzed and the method was successfully applied. The results proved that this method can be an important tool in routine analysis, since it is very fast and reliable. Copyright © 2014. Published by Elsevier B.V.
Pappula, Nagaraju; Kodali, Balaji; Datla, Peda Varma
2018-04-15
Highly selective and fast liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for simultaneous determination of tadalafil (TDL) and finasteride (FNS) in human plasma. The method was successfully applied for analysis of TDL and FNS samples in clinical study. The method was validated as per USFDA (United States Food and Drug Administration), EMA (European Medicines Agency), and ANVISA (Agência Nacional de Vigilância Sanitária-Brazil) bio analytical method validation guidelines. Glyburide (GLB) was used as common internal standard (ISTD) for both analytes. The selected multiple reaction monitoring (MRM) transitions for mass spectrometric analysis were m/z 390.2/268.2, m/z 373.3/305.4 and m/z 494.2/369.1 for TDL, FNS and ISTD respectively. The extraction of analytes and ISTD was accomplished by a simple solid phase extraction (SPE) procedure. Rapid analysis time was achieved on Zorbax Eclipse C18 column (50 × 4.6 mm, 5 μm). The calibration ranges for TDL and FNS were 5-800 ng/ml and 0.2-30 ng/ml respectively. The results of precision and accuracy, linearity, recovery and matrix effect of the method are acceptable. The accuracy was in the range of 92.9%-106.4% and method precision was also good; %CV was less than 8.1%. Copyright © 2018 Elsevier B.V. All rights reserved.
Wojnicz, Aneta; Cabaleiro-Ocampo, Teresa; Román-Martínez, Manuel; Ochoa-Mazarro, Dolores; Abad-Santos, Francisco; Ruiz-Nuño, Ana
2013-11-15
A simple, reproducible and fast (4 min chromatogram) method of liquid chromatography in tandem with mass spectrometry (LC/MS-MS) was developed to determine simultaneously the plasma levels of albendazole (ABZ) and its metabolite albendazole sulfoxide (ABZOX) for pharmacokinetic and clinical analysis. Each plasma sample was extracted by solid phase extraction (SPE) using phenacetin as internal standard (IS). The extracted sample was eluted with a Zorbax XDB-CN column using an isocratic method. The mobile phase consisting of water with 1% acetic acid (40%, A) and MeOH (60%, B), was used at a flow rate of 1 mL/min. ABZ and ABZOX were detected and identified by mass spectrometry with electrospray ionization (ESI) in the positive ion and multiple-reaction monitoring (MRM) mode. The method was linear in the range of 5-1000 ng/mL for ABZ and 10-1500 ng/mL (full validation) or 10-5000 ng/mL (partial validation) for ABZOX, with 5 and 10 ng/mL lower limit of quantification (LLOQ) for ABZ and ABZOX, respectively. The tests of accuracy and precision, matrix effect, extraction recovery and stability of the samples for both ABZ and ABZOX did not deviate more than 20% for the LLOQ and no more than 15% for other quality controls (QCs), according to regulatory agencies. © 2013.
Jiménez-Díaz, I; Vela-Soria, F; Rodríguez-Gómez, R; Zafra-Gómez, A; Ballesteros, O; Navalón, A
2015-09-10
In the present work, a review of the analytical methods developed in the last 15 years for the determination of endocrine disrupting chemicals (EDCs) in human samples related with children, including placenta, cord blood, amniotic fluid, maternal blood, maternal urine and breast milk, is proposed. Children are highly vulnerable to toxic chemicals in the environment. Among these environmental contaminants to which children are at risk of exposure are EDCs -substances able to alter the normal hormone function of wildlife and humans-. The work focuses mainly on sample preparation and instrumental techniques used for the detection and quantification of the analytes. The sample preparation techniques include, not only liquid-liquid extraction (LLE) and solid-phase extraction (SPE), but also modern microextraction techniques such as extraction with molecular imprinted polymers (MIPs), stir-bar sorptive extraction (SBSE), hollow-fiber liquid-phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME), matrix solid phase dispersion (MSPD) or ultrasound-assisted extraction (UAE), which are becoming alternatives in the analysis of human samples. Most studies focus on minimizing the number of steps and using the lowest solvent amounts in the sample treatment. The usual instrumental techniques employed include liquid chromatography (LC), gas chromatography (GC) mainly coupled to tandem mass spectrometry. Multiresidue methods are being developed for the determination of several families of EDCs with one extraction step and limited sample preparation. Copyright © 2015 Elsevier B.V. All rights reserved.
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Fang; Liu, Tao; Qian, Weijun
2011-07-22
Liquid chromatography-mass spectrometry (LC-MS)-based quantitative proteomics has become increasingly applied for a broad range of biological applications due to growing capabilities for broad proteome coverage and good accuracy in quantification. Herein, we review the current LC-MS-based quantification methods with respect to their advantages and limitations, and highlight their potential applications.
Nano-liquid chromatography applied to enantiomers separation.
Fanali, Salvatore
2017-02-24
This paper presents the state of the art concerning the separation of chiral compounds by means of nano-liquid chromatography (nano-LC). The enantiomers' separation and determination are a subject of fundamental importance in various application fields such as pharmaceutical industry, biomedicine, food, agrochemical etc. Nano-LC is a miniaturized chromatographic technique offering some advantages over conventional ones such as low consumption of mobile phase, sample volume and amount of chiral stationary phase, reduced costs etc. This is reported in the first part of the paper illustrating the features of the nano-LC. In addition, chiral resolution methods are briefly illustrated. Some chiral selectors, used in high-performance liquid chromatography have also been applied in nano-LC including cyclodextrins, glycopeptide antibiotics, modified polysaccharides etc. This is discussed in the second part of the review. Finally some examples of the applications available in literature are reported. Copyright © 2016 Elsevier B.V. All rights reserved.
SPE-HPTLC of procyanidins from the barks of different species and clones of Salix.
Pobłocka-Olech, Loretta; Krauze-Baranowska, Mirosława
2008-11-04
A SPE-HPTLC method was developed for the qualitative and quantitative analysis of procyanidin B(1) in willow barks. The chromatography was performed on HPTLC silica gel layer with the mobile phase chloroform-ethanol-formic acid (50:40:6 v/v/v), in the Automatic Developing Chamber-ADC 2. The methanol extracts from willow barks were purified by SPE method on RP-18 silica gel columns with methanol-water (7:93 v/v) as the eluent. The presence of procyanidin B(1) was revealed in the majority of investigated willow barks. The content of procyanidin B(1) varied from 0.26 mg/g in the extract of Salix purpurea clone 1067-2.24 mg/g in the extract of Salix alba clone 1100. The method was validated for linearity, precision, LOD, LOQ and repeatability.
Structures of Bacterial Biosynthetic Arginine Decarboxylases
DOE Office of Scientific and Technical Information (OSTI.GOV)
F Forouhar; S Lew; J Seetharaman
2011-12-31
Biosynthetic arginine decarboxylase (ADC; also known as SpeA) plays an important role in the biosynthesis of polyamines from arginine in bacteria and plants. SpeA is a pyridoxal-5'-phosphate (PLP)-dependent enzyme and shares weak sequence homology with several other PLP-dependent decarboxylases. Here, the crystal structure of PLP-bound SpeA from Campylobacter jejuni is reported at 3.0 {angstrom} resolution and that of Escherichia coli SpeA in complex with a sulfate ion is reported at 3.1 {angstrom} resolution. The structure of the SpeA monomer contains two large domains, an N-terminal TIM-barrel domain followed by a {beta}-sandwich domain, as well as two smaller helical domains. Themore » TIM-barrel and {beta}-sandwich domains share structural homology with several other PLP-dependent decarboxylases, even though the sequence conservation among these enzymes is less than 25%. A similar tetramer is observed for both C. jejuni and E. coli SpeA, composed of two dimers of tightly associated monomers. The active site of SpeA is located at the interface of this dimer and is formed by residues from the TIM-barrel domain of one monomer and a highly conserved loop in the {beta}-sandwich domain of the other monomer. The PLP cofactor is recognized by hydrogen-bonding, {pi}-stacking and van der Waals interactions.« less
NASA Astrophysics Data System (ADS)
Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi
2014-06-01
Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.
Careri, M; Elviri, L; Mangia, A
1999-08-27
The investigation of beta-carotene and the xanthophylls beta-cryptoxanthin, lutein, zeaxanthin, canthaxanthin and astaxanthin using reversed-phase liquid chromatography-electrospray mass spectrometry interfaced with TurboIonspray (LC-TurboISP-MS) is described. Two narrow-bore C18 columns connected in series and an isocratic solvent system containing acetonitrile-methanol (0.1 M ammonium acetate)-dichloromethane at a flow-rate of 300 microl/min (without splitting) were used. Operating in the positive-ion mode over m/z 500-650, the effects on the formation of the molecular ion species or adduct ions and the MS detector response were investigated for carotenoids, varying the orifice plate voltage, the ring voltage and the ISP voltage. Both conventional ISP and TurboISP were performed; using the TurboISP-MS system, ionization efficiency increased with respect to ISP-MS, particularly at the highest temperature (500 degrees C). Good results were particularly obtained for beta-carotene, which was detectable at the low ng level, without the use of solution-phase oxidants. Using LC columns and acquiring in single-ion monitoring mode, detection limits were estimated to be in the 0.1-1 ng range; dynamic range was established between one- and two-orders of magnitude. Better sensitivity under positive-ion than negative-ion conditions was demonstrated.
Kaufmann, A; Butcher, P; Maden, K; Walker, S; Widmer, M
2010-07-12
The selectivity of mass traces obtained by monitoring liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was compared. A number of blank extracts (fish, pork kidney, pork liver and honey) were separated by ultra performance liquid chromatography (UPLC). Detected were some 100 dummy transitions respectively dummy exact masses (traces). These dummy masses were the product of a random generator. The range of the permitted masses corresponded to those which are typical for analytes (e.g. veterinary drugs). The large number of monitored dummy traces ensured that endogenous compounds present in the matrix extract, produced a significant number of detectable chromatographic peaks. All obtained chromatographic peaks were integrated and standardized. Standardisation was done by dividing these absolute peak areas by the average response of a set of 7 different veterinary drugs. This permitted a direct comparison between the LC-HRMS and LC-MS/MS data. The data indicated that the selectivity of LC-HRMS exceeds LC-MS/MS, if high resolution mass spectrometry (HRMS) data is recorded with a resolution of 50,000 full width at half maximum (FWHM) and a corresponding mass window. This conclusion was further supported by experimental data (MS/MS based trace analysis), where a false positive finding was observed. An endogenous matrix compound present in honey matrix behaved like a banned nitroimidazole drug. This included identical retention time and two MRM traces, producing an MRM ratio between them, which perfectly matched the ratio observed in the external standard. HRMS measurement clearly resolved the interfering matrix compound and unmasked the false positive MS/MS finding. Copyright 2010 Elsevier B.V. All rights reserved.
Data is presented showing the progress made towards the development of a new automated system combining solid phase extraction (SPE) with gas chromatography/mass spectrometry for the single run analysis of water samples containing a broad range of acid, base and neutral compounds...
Martel, Jan; Young, David; Young, Andrew; Wu, Cheng-Yeu; Chen, Chi-De; Yu, Jau-Song; Young, John D
2011-11-01
Mineralo-protein nanoparticles (NPs) formed spontaneously in the body have been associated with ectopic calcifications seen in atherosclerosis, chronic degenerative diseases, and kidney stone formation. Synthetic NPs are also known to become coated with proteins when they come in contact with body fluids. Identifying the proteins found in NPs should help unravel how NPs are formed in the body and how NPs in general, be they synthetic or naturally formed, interact within the body. Here, we developed a proteomic approach based on liquid chromatography (LC) and tandem mass spectrometry (MS/MS) to determine the protein composition of carbonate-apatite NPs derived from human body fluids (serum, urine, cerebrospinal fluid, ascites, pleural effusion, and synovial fluid). LC-MS/MS provided not only an efficient and comprehensive determination of the protein constituents, but also a semiquantitative ranking of the identified proteins. Notably, the identified NP proteins mirrored the protein composition of the contacting body fluids, with albumin, fetuin-A, complement C3, α-1-antitrypsin, prothrombin, and apolipoproteins A1 and B-100 being consistently associated with the particles. Since several coagulation factors, calcification inhibitors, complement proteins, immune regulators, protease inhibitors, and lipid/molecule carriers can all become NP constituents, our results suggest that mineralo-protein complexes may interface with distinct biochemical pathways in the body depending on their protein composition. We propose that LC-MS/MS be used to characterize proteins found in both synthetic and natural NPs. Copyright © 2011 Elsevier Inc. All rights reserved.
Manini, P; Andreoli, R; Mutti, A; Bergamaschi, E; Niessen, W M
1998-01-01
A liquid chromatography atmospheric pressure electrospray mass spectrometry (ESI-LC/MS) system was evaluated for the identification and characterization of n-hexane conjugated metabolites (glucuronides) in untreated urine samples. Chromatography of glucuronides was obtained under ion-suppressed reversed-phase conditions, by using high-speed (3 cm, 3 microns) columns and formic acid (2 mM) as modifier in the mobile phase. The mass spectrometer was operated in negative ion (NI) mode. For the first time, four glucuronides were identified by ESI-LC/MS in untreated urine samples of rats exposed to n-hexane: 2-hexanol-glucuronide, 5-hydroxy-2-hexanone-glucuronide, 2,5-hexanediol-glucuronide and 4,5-dihydroxy-2-hexanone-glucuronide. Confirmation of the conjugated metabolites was obtained by LC/MS/MS experiments. Gas chromatography/mass spectrometry (GC/MS) and atmospheric pressure chemical ionization (APCI) LC/MS analyses were performed on the same samples. An integrated approach GC/MS-LC/MS for the semi-quantitative analysis of n-hexane glucuronides, whose standards are not commercially available, is discussed and proposed here. In order to understand the fate of the metabolites during sample pre-treatment, a study about the effects of enzymatic and acid hydrolysis on urine samples was conducted on glucuronides isolated by solid-phase extraction. Combined analyses by GC/MS and LC/MS enabled us to distinguish 'true' n-hexane metabolites from compounds resulting from sample treatment and handling (i.e. enzymatic and acid hydrolysis, extraction and GC injection).
Investigation of Air-Liquid Interface Rings in Buffer Preparation Vessels: the Role of Slip Agents.
Shi, Ting; Ding, Wei; Kessler, Donald W; De Mas, Nuria; Weaver, Douglas G; Pathirana, Charles; Martin, Russell D; Mackin, Nancy A; Casati, Michael; Miller, Scott A; Pla, Itzcoatl A
2016-01-01
Air-liquid interface rings were observed on the side walls of stainless steel buffer vessels after certain downstream buffer preparations. Those rings were resistant to regular cleaning-in-place procedures but could be removed by manual means. To investigate the root cause of this issue, multiple analytical techniques, including liquid chromatography with tandem mass spectrometry detection (LC-MS/MS), high-resolution accurate mass liquid chromatography with mass spectrometry, nuclear magnetic resonance, Fourier transform infrared spectroscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy have been employed to characterize the chemical composition of air-liquid interface rings. The main component of air-liquid interface rings was determined to be slip agents, and the origin of the slip agents can be traced back to their presence on raw material packaging liners. Slip agents are commonly used in plastic industry as additives to reduce the coefficient of friction during the manufacturing process of thin films. To mitigate this air-liquid interface ring issue, an alternate liner with low slip agent was identified and implemented with minimal additional cost. We have also proactively tested the packaging liners of other raw materials currently used in our downstream buffer preparation to ensure slip agent levels are appropriate. Air-liquid interface rings were observed on the side walls of stainless steel buffer vessels after certain downstream buffer preparations. To investigate the root cause of this issue, multiple analytical techniques have been employed to characterize the chemical composition of air-liquid interface rings. The main components of air-liquid interface rings were determined to be slip agents, which are common additives used in the manufacturing process of thin films. The origin of the slip agents can be traced back to their presence on certain raw material packaging liners. To mitigate this air-liquid interface ring issue, an alternate liner with low slip agent was identified and implemented. © PDA, Inc. 2016.
Du, Li-Jing; Yi, Ling; Ye, Li-Hong; Chen, Yu-Bo; Cao, Jun; Peng, Li-Qing; Shi, Yu-Ting; Wang, Qiu-Yan; Hu, Yu-Han
2018-02-16
A simple and effective method of miniaturized solid-phase extraction (mini-SPE) was developed for the simultaneous purification and enrichment of macrolide antibiotics (MACs) (i.e. azithromycin, clarithromycin, erythromycin, lincomycin and roxithromycin) from honey and skim milk. Mesoporous MCM-41 silica was synthesized and used as sorbent in mini-SPE. Several key parameters affecting the performance of mini-SPE procedure were thoroughly investigated, including sorbent materials, amount of sorbent and elution solvents. Under the optimized condition, satisfactory linearity (r 2 > 0.99), acceptable precision (RSDs, 0.3-7.1%), high sensitivity (limit of detection in the range of 0.01-0.76 μg/kg), and good recoveries (83.21-105.34%) were obtained. With distinct advantages of simplicity, reliability and minimal sample requirement, the proposed mini-SPE procedure coupled with ultrahigh performance liquid chromatography and quadrupole time-of-flight tandem mass spectrometry could become an alternative tool to analyze the residues of MACs in complex food matrixes. Copyright © 2018 Elsevier B.V. All rights reserved.
El-Sheikh, Amjad H; Sweileh, Jamal A; Al-Degs, Yahya S; Insisi, Ahmad A; Al-Rabady, Nancy
2008-02-15
In this work, optimization of multi-residue solid phase extraction (SPE) procedures coupled with high-performance liquid chromatography for the determination of Propoxur, Atrazine and Methidathion from environmental waters is reported. Three different sorbents were used in this work: multi-walled carbon nanotubes (MWCNTs), C18 silica and activated carbon (AC). The three optimized SPE procedures were compared in terms of analytical performance, application to environmental waters, cartridge re-use, adsorption capacity and cost of adsorbent. Although the adsorption capacity of MWCNT was larger than AC and C18, however, the analytical performance of AC could be made close to the other sorbents by appropriate optimization of the SPE procedures. A sample of AC was then oxidized with various oxidizing agents to show that ACs of various surface properties has different enrichment efficiencies. Thus researchers are advised to try AC of various surface properties in SPE of pollutants prior to using expensive sorbents (such as MWCNT and C18 silica).
García-Valverde, María Teresa; Rosende, María; Lucena, Rafael; Cárdenas, Soledad; Miró, Manuel
2018-04-03
Mesofluidic lab-on-a-valve (LOV) platforms have been proven suitable to accommodate automatic micro-solid-phase extraction (μSPE) approaches with on-chip handling of micrometer-bead materials in a fully disposable mode to prevent sample cross-contamination and pressure-drop effects. The efficiency of the extraction process notably depends upon the sorptive capacity of the material because the sorbent mass is usually down to 10 mg in LOV devices. Nanomaterials, capitalizing upon their enhanced surface-to-volume ratio and diversity of potential chemical moieties, are appealing alternatives to microbead sorbents. However, the handling and confinement of nanomaterials in fluidic chip structures have been challenging to date. This is most likely a consequence of the aggregation tendency of a number of nanomaterials, including carbon-based sorbents, that leads to excessive back-pressure in flowing systems along with irreproducible bead loading. This paper addresses these challenges by ad hoc synthesis of hybrid nanomaterials, such as porous carbon-coated titanium dioxide nanotubes (TiO 2 -NT@pC). Tailoring of the surface polarity of the carbon coating is proven to foster the dispersion of TiO 2 -NT@pC in LOV settings while affording superior extraction capability of moderately nonpolar species from aqueous matrices. The determination of trace-level concentrations of butylparaben (BPB) and triclosan (TCS) in seawater samples is herein selected as a proof-of-concept of the exploitation of disposable nanomaterials in LOV. The mesofluidic platform accommodating μSPE features online hyphenation to liquid chromatography/tandem mass spectrometry (LC/MS/MS) for reliable determination of the target analytes with excellent limits of detection (0.5 and 0.6 ng/L for BPB and TCS, respectively) and intermediate precision (relative standard deviation <5.8%). For 5.0 mL of sample and 200 μL of eluent, enrichment factors of 23 and 14 with absolute extraction efficiencies of 90% ± 14% and 58 ± 8% for BPB and TCS, respectively, were obtained. The relative recovery values of 107% (BPB) and 97% (TCS) in seawater demonstrate the applicability of online LOV-LC/MS/MS using TiO 2 -NT@pC for handling troublesome environmental samples.
Daschner De Tercero, Maren; Abbott, Nicholas L.
2013-01-01
Recent studies have reported that full monolayers of L-α-dilaurylphosphatidylcholine (L-DLPC) and D-α-dipalmitoylphosphatidylcholine (D-DPPC) formed at interfaces between thermotropic liquid crystals (LCs) and aqueous phases lead to homeotropic (perpendicular) orientations of nematic LCs and that specific binding of proteins to these interfaces (such as phospholipase A2 binding to D-DPPC) can trigger orientational ordering transitions in the liquid crystals. We report on the nonspecific interactions of proteins with aqueous-LC interfaces decorated with partial monolayer coverage of L-DLPC. Whereas nonspecific interactions of four proteins (cytochrome c, bovine serum albumin,immunoglobulins, and neutravidin) do not perturb the ordering of the LC when a full monolayer of L-DLPC is assembled at the aqueous-LC interface, we observe patterned orientational transitions in the LC that reflect penetration of proteins into the interface of the LC with partial monolayer coverage of L-DLPC. The spatial patterns formed by the proteins and lipids at the interface are surprisingly complex, and in some cases the protein domains are found to compartmentalize lipid within the interfaces. These results suggest that phospholipid-decorated interfaces between thermotropic liquid crystals and aqueous phases offer the basis of a simple and versatile tool to study the spatial organization and dynamics ofprotein networks formed at mobile, lipid-decorated interfaces. PMID:23671353
Hand-portable liquid chromatographic instrumentation.
Sharma, Sonika; Tolley, Luke T; Tolley, H Dennis; Plistil, Alex; Stearns, Stanley D; Lee, Milton L
2015-11-20
Over the last four decades, liquid chromatography (LC) has experienced an evolution to smaller columns and particles, new stationary phases and low flow rate instrumentation. However, the development of person-portable LC has not followed, mainly due to difficulties encountered in miniaturizing pumps and detectors, and in reducing solvent consumption. The recent introduction of small, non-splitting pumping systems and UV-absorption detectors for use with capillary columns has finally provided miniaturized instrumentation suitable for high-performance hand-portable LC. Fully integrated microfabricated LC still remains a significant challenge. Ion chromatography (IC) has been successfully miniaturized and applied for field analysis; however, applications are mostly limited to inorganic and small organic ions. This review covers advancements that make possible more rapid expansion of portable forms of LC and IC. Copyright © 2015 Elsevier B.V. All rights reserved.
Amphiphile-Induced Reorganization of Nematic Liquid Crystals at Aqueous Interfaces
NASA Astrophysics Data System (ADS)
Rahimi, Amin; Ramezani-Dakhel, Hadi; Pendery, Joel; Abbott, Nicholas; de Pablo, Juan; Juan de Pablo Team, Prof; Nicholas Abbott Collaboration, Prof
Recent studies have shown that ordering transitions in 4-cyano-4'-pentylbiphenyl (5CB) molecules can be triggered by the self-assembly of specific amphiphiles near a flat aqueous-LC interface. In the absence of adsorbed amphiphiles, LC molecules adopt a parallel orientation at the aqueous interface. Self-assembly of amphiphile molecules at the LC-aqueous interface triggers a spontaneous reorientation of the LC at the aqueous interface. A number of observations indicate that the hydrophilic headgroup of the surfactant has marginal effect on the orientation of 5CB whereas the aliphatic tail structure, length, and conformation greatly affect the ordering of the LC. The structural reorganization of liquid crystals at aqueous interfaces has been primarily ascribed to a weakening of the surface anchoring strength induced by amphiphile molecules. Such explanations, however, have only been supported by a posteriorimicroscopic observations. The underlying mechanism of such an ordering transition and the effect of amphiphile structure remain poorly understood. Here, we study the nature of molecular interactions between amphiphiles, 5CB, and water to understand the mechanism of ordering transitions using atomistic molecular dynamics simulations.
Li, Duxin; Schmitz, Oliver J
2013-08-01
Comprehensive two-dimensional liquid chromatography (LC × LC) has received much attention because it offers much higher peak capacities than separation in a single dimension. The advantageous peak capacity makes it attractive for the separation of complex samples. Various gradient methods have been used in LC × LC systems. The use of continuous shift gradient is advantageous because it combines the peak compression effect of full gradient mode and the tailed gradient program in parallel gradient mode. Here, a comparison of LC × LC analysis of Chinese herbal medicine with full gradient mode and shift gradient mode in the second dimension was performed. A correlation between the first and second dimensions was found in full gradient mode, and this was significantly reduced with shift gradient mode. The orthogonality increased by 43.7%. The effective peak distribution area increased significantly, which produced better separation.
Aga, D.S.; Thurman, E.M.
1993-01-01
Solid-phase extraction (SPE) and enzyme-linked immunosorbent assay (ELISA) were coupled for automated trace analysis of pristine water samples containing 2-chloro-4-ethylamino-6-isopropylamine-s-triazine (atrazine) and 2-chloro-2???,6???-diethyl-N-(methoxymethyl)acetanilide (alachlor). The isolation of the two herbicides on a C18-resin involved the selection of an elution solvent that both removes interfering substances and is compatible with ELISA. Ethyl acetate was selected as the elution solvent followed by a solvent exchange with methanol/water (20/80, % v/v). The SPE-ELISA method has a detection limit of 5.0 ng/L (5 ppt), >90% recovery, and a relative standard deviation of ??10%. The performance of a microtiter plate-based ELISA and a magnetic particle-based ELISA coupled to SPE was also evaluated. Although the sensitivity of the two ELISA methods was comparable, the precision using magnetic particles was improved considerably (??10% versus ??20%) because of the faster reaction kinetics provided by the magnetic particles. Finally, SPE-ELISA and isotope dilution gas chromatography/ mass spectrometry correlated well (correlation coefficient of 0.96) for lake-water samples. The SPE-ELISA method is simple and may have broader applications for the inexpensive automated analysis of other contaminants in water at trace levels.
Janiszewski, J; Schneider, P; Hoffmaster, K; Swyden, M; Wells, D; Fouda, H
1997-01-01
The development and application of membrane solid phase extraction (SPE) in 96-well microtiter plate format is described for the automated analysis of drugs in biological fluids. The small bed volume of the membrane allows elution of the analyte in a very small solvent volume, permitting direct HPLC injection and negating the need for the time consuming solvent evaporation step. A programmable liquid handling station (Quadra 96) was modified to automate all SPE steps. To avoid drying of the SPE bed and to enhance the analytical precision a novel protocol for performing the condition, load and wash steps in rapid succession was utilized. A block of 96 samples can now be extracted in 10 min., about 30 times faster than manual solvent extraction or single cartridge SPE methods. This processing speed complements the high-throughput speed of contemporary high performance liquid chromatography mass spectrometry (HPLC/MS) analysis. The quantitative analysis of a test analyte (Ziprasidone) in plasma demonstrates the utility and throughput of membrane SPE in combination with HPLC/MS. The results obtained with the current automated procedure compare favorably with those obtained using solvent and traditional solid phase extraction methods. The method has been used for the analysis of numerous drug prototypes in biological fluids to support drug discovery efforts.
Mi, Si; Lim, David W; Turner, Justine M; Wales, Paul W; Curtis, Jonathan M
2016-03-01
An LC/MS/MS-based method was developed for the determination of individual bile acids (BA) and their conjugates in porcine bile samples. The C18-based solid-phase extraction (SPE) procedure was optimized so that all 19 target BA and their glycine and taurine conjugates were collected with high recoveries for standards (89.1-100.2%). Following this, all 19 compounds were separated and quantified in a single 12 min chromatographic run. The method was validated in terms of linearity, sensitivity, accuracy, precision, and recovery. An LOD in the low ppb range with measured precisions in the range of 0.5-9.3% was achieved. The recoveries for all of the 19 analytes in bile samples were all >80%. The validated method was successfully applied to the profiling of BA and their conjugates in the bile from piglets treated with exogenous glucagon-like peptide-2 (GLP-2) in a preclinical model of neonatal parenteral nutrition-associated liver disease (PNALD). The method developed is rapid and could be easily implemented for routine analysis of BA and their conjugates in other biofluids or tissues.
Afonso-Olivares, Cristina; Torres-Padrón, Mª Esther; Sosa-Ferrera, Zoraida; Santana-Rodríguez, José Juan
2013-01-01
This study presents the evaluation of seven pharmaceutical compounds belonging to different commonly used therapeutic classes in seawater samples from coastal areas of Gran Canaria Island. The target compounds include atenolol (antihypertensive), acetaminophen (analgesic), norfloxacin and ciprofloxacin (antibiotics), carbamazepine (antiepileptic) and ketoprofen and diclofenac (anti-inflammatory). Solid phase extraction (SPE) was used for the extraction and preconcentration of the samples, and liquid chromatography tandem mass spectrometry (LC-MS/MS) was used for the determination of the compounds. Under optimal conditions, the recoveries obtained were in the range of 78.3% to 98.2%, and the relative standard deviations were less than 11.8%. The detection and quantification limits of the method were in the ranges of 0.1–2.8 and 0.3–9.3 ng·L−1, respectively. The developed method was applied to evaluate the presence of these pharmaceutical compounds in seawater from four outfalls in Gran Canaria Island (Spain) during one year. Ciprofloxacin and norfloxacin were found in a large number of samples in a concentration range of 9.0–3551.7 ng·L−1. Low levels of diclofenac, acetaminophen and ketoprofen were found sporadically. PMID:27029304
Biomonitoring of perfluorinated compounds in a drop of blood.
Mao, Pan; Wang, Daojing
2015-06-02
Biomonitoring of pollutants and their metabolites and derivatives using biofluids provides new opportunities for spatiotemporal assessment of human risks to environmental exposures. Perfluorinated compounds (PFCs) have been used widely in industry and pose significant environmental concerns due to their stability and bioaccumulation in humans and animals. However, current methods for extraction and measurement of PFCs require relatively large volumes (over one hundred microliters) of blood samples, and therefore, are not suitable for frequent blood sampling and longitudinal biomonitoring of PFCs. We have developed a new microassay, enabled by our silicon microfluidic chip platform, for analyzing PFCs in small volumes (less than five microliters) of blood. Our assay integrates on-chip solid-phase extraction (SPE) with online nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nanoLC-ESI-MS) detection. We demonstrated high sample recovery, excellent interday and intraday accuracy and precision, and a limit of detection down to 50 femtogram of PFCs, in one microliter of human plasma. We validated our assay performance using pooled human plasma and NIST SRM 1950 samples. Our microfluidic chip-based assay may enable frequent longitudinal biomonitoring of PFCs and other environmental toxins using a finger prick of blood, thereby providing new insights into their bioaccumulation, bioavailability, and toxicity.
Kim, Woojung; Lee, Yunho; Kim, Sang Don
2017-11-01
The overuse of oxytetracycline (OTC) in aquaculture has become a problem because of its chronic toxic effects on marine ecosystems. The present study assessed the ecological risk of OTC in the coastal waters near the Jangheung Flatfish Farm using a site-specific multimedia fate model to analyze exposure. Before the model was applied, its performance was validated by comparing it with field data. The coastal waters in the testbed were sampled and analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) followed by solid-phase extraction (SPE). The concentrations of OTC measured varied from 7.05 to 95.39ng/L. The results of validating the models showed that the site-specific multimedia fate model performed better (root mean square error (RMSE): 24.217, index of agreement (IOA): 0.739) than conventional fugacity approaches. This result demonstrated the utility of this model in supporting effective future management of aquaculture effluent. The results of probabilistic risk assessment indicated that OTC from aquaculture effluent did not cause adverse effects, even in a maximum-use scenario. Copyright © 2017 Elsevier Inc. All rights reserved.
Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.
Santa, Tomofumi
2011-01-01
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.
Lavrik, N V; Taylor, L T; Sepaniak, M J
2011-05-23
Pressure driven liquid chromatography (LC) is a powerful and versatile separation technique particularly suitable for differentiating species present in extremely small quantities. This paper briefly reviews main historical trends and focuses on more recently developed technological approaches in miniaturization and on-chip integration of LC columns. The review emphasizes enabling technologies as well as main technological challenges specific to pressure driven separations and highlights emerging concepts that could ultimately overcome fundamental limitations of conventional LC columns. Copyright © 2011 Elsevier B.V. All rights reserved.
Wagner, Rebecca; Wetzel, Stephanie J; Kern, John; Kingston, H M Skip
2012-02-01
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time-consuming derivatization for gas chromatography-mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid-phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization-quadrupole time-of-flight mass spectrometry (APCI-Q-TOF-MS) that does not require derivatization. Solid-phase extraction-isotope dilution mass spectrometry (SPE-IDMS) involves pre-equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i-Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co-eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI-Q-TOF-MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.
An enhanced procedure for measuring organic acids and methyl esters in PM2.5
NASA Astrophysics Data System (ADS)
Liu, F.; Duan, F. K.; He, K. B.; Ma, Y. L.; Rahn, K. A.; Zhang, Q.
2015-11-01
A solid-phase extraction (SPE) pretreatment procedure allowing organic acids to be separated from methyl esters in fine aerosol has been developed. The procedure first separates the organic acids from fatty acid methyl esters (FAMEs) and other nonacid organic compounds by aminopropyl-based SPE cartridge and then quantifies them by gas chromatography/mass spectrometry. The procedure prevents the fatty acids and dimethyl phthalate from being overestimated, and so allows us to accurately quantify the C4-C11 dicarboxylic acids (DCAs) and the C8-C30 monocarboxylic acids (MCAs). Results for the extraction of DCAs, MCAs, and AMAs in eluate and FAMEs in effluate by SAX and NH2 SPE cartridges exhibited that the NH2 SPE cartridge gave higher extraction efficiency than the SAX cartridge. The recoveries of analytes ranged from 67.5 to 111.3 %, and the RSD ranged from 0.7 to 10.9 %. The resulting correlations between the aliphatic acids and FAMEs suggest that the FAMEs had sources similar to those of the carboxylic acids, or were formed by esterifying carboxylic acids, or that aliphatic acids were formed by hydrolyzing FAMEs. Through extraction and cleanup using this procedure, 17 aromatic acids in eluate were identified and quantified by gas chromatography/tandem mass spectrometry, including five polycyclic aromatic hydrocarbon (PAH): acids 2-naphthoic, biphenyl-4-carboxylic, 9-oxo-9H-fluorene-1-carboxylic, biphenyl-4,4´-dicarboxylic, and phenanthrene-1-carboxylic acid, plus 1,8-naphthalic anhydride. Correlations between the PAH acids and the dicarboxylic and aromatic acids suggested that the first three acids and 1,8-naphthalic anhydride were secondary atmospheric photochemistry products and the last two mainly primary.
Chen, Xiao-Hong; Zhao, Yong-Gang; Shen, Hao-Yu; Zhou, Li-Xin; Pan, Sheng-Dong; Jin, Mi-Cong
2014-06-13
A novel, simple and sensitive method based on the use of magnetic dispersive solid-phase extraction (M-dSPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) was developed to determine seven synthetic pigments (tartrazine, amaranth, carmine, sunset yellow, allura red, brilliant blue and erythrosine) in wines and soft drinks. An amino-functionalized low degrees of cross-linking magnetic polymer (NH2-LDC-MP) was synthesized via suspension polymerization, and characterized by transmission electron microscopy (TEM). The NH2-LDC-MP was used as the M-dSPE sorbent to remove the matrix from the solution, and the main factors affecting the extraction were investigated in detail. The obtained results demonstrated the higher extraction capacity of NH2-LDC-MP with recoveries between 84.0 and 116.2%. The limits of quantification (LOQs) for the seven synthetic pigments were between 1.51 and 5.0μg/L in wines and soft drinks. The developed M-dSPE UFLC-MS/MS method had been successfully applied to the real wines and soft drinks for food-safety risk monitoring in Zhejiang Province, China. The results showed that sunset yellow was in three out of thirty soft drink samples (2.95-42.6μg/L), and erythrosine in one out of fifteen dry red wine samples (3.22μg/L), respectively. It was confirmed that the NH2-LDC-MP was a kind of highly effective M-dSPE materials for the pigments analyses. Copyright © 2014 Elsevier B.V. All rights reserved.
Purification and characterization of substance P endopeptidase activities in the rat spinal cord.
Karlsson, K; Eriksson, U; Andrén, P; Nyberg, F
1997-02-01
Two enzymes with substance P degrading activity were purified from the membrane bound fraction of the rat spinal cord. The purified enzymes were characterized with regard to biochemical and kinetic properties. One of the enzymes exhibited close similarity to neutral endopeptidase 24.11 (NEP, EC 3.4.24.11), while the other resembled a substance P converting endopeptidase (SPE), which has previously been identified and purified from human cerebrospinal fluid (CSF). Detergent treated spinal cord homogenates from male Sprague Dawley rats were purified by anion-exchange chromatography (DEAE-sepharose CL-6B), hydrophobic-interaction chromatography (phenyl-sepharose CL-4B) and molecular sieving (Sephadex G-50). Two fractions with enzymes differing in size were recovered and allowed for further purification to apparent homogeneity by ion-exchange chromatography and molecular sieving on a micro-purification system (SMART). The enzyme activities were monitored by following the conversion of synthetic substance P using a radioimmunoassay specific for the heptapeptide product, substance P (1-7). By SDS-polyacrylamide gel electrophoresis of the purified enzymes molecular weights of 43 and 70 kDa were estimated for the SPE-like and NEP-like activity, respectively. A K(m) of 5 microM was determined for the conversion of substance P to its (1-7) fragment by the SPE-like activity. Reversed-phase HPLC together with mass spectrometry permitted identification of all fragments released from substance P by the peptidases. The released fragments were for both enzymes identified as substance P (1-7), substance P (8-11), substance P (1-8), substance P (9-11). The NEP-like enzyme preparation also gave substance P (1-6) as a major product.
Billian; Hock; Doetzer; Stan; Dreher
2000-10-15
The identification of n-decyl alpha(1-->6)isomaltoside as a main component of technical alkyl polyglucoside (APG) mixtures by the parallel use of liquid chromatography-mass spectrometry (LC-MS) and nuclear magnetic resonance (NMR) spectroscopy is described. Following enrichment on a styrene-divinylbenzene-based solid-phase extraction material, unknown components were separated by reversed-phase liquid chromatography (LC). Chemical characterization was achieved by both mass spectrometry and NMR spectroscopy. It is demonstrated that the combination of LC-MS with various NMR techniques is very suitable for stereochemical assignment of unknown components in technical APG mixtures.
Chao, Mu-Rong; Wang, Chien-Jen; Yen, Cheng-Chieh; Yang, Hsi-Hsien; Lu, Yao-Cheng; Chang, Louis W.; Hu, Chiung-Wen
2006-01-01
In the present study, we report the development of a sensitive and selective assay based on LC (liquid chromatography)–MS/MS (tandem MS) to simultaneously measure N7-MeG (N7-methylguanine) and N7-EtG (N7-ethylguanine) in DNA hydrolysates. With the use of isotope internal standards (15N5-N7-MeG and 15N5-N7-EtG) and on-line SPE (solid-phase extraction), the detection limit of this method was estimated as 0.42 fmol and 0.17 fmol for N7-MeG and N7-EtG respectively. The high sensitivity achieved here makes this method applicable to small experimental animals. This method was applied to measure N7-alkylguanines in liver DNA from mosquito fish (Gambusia affinis) that were exposed to NDMA (N-nitrosodimethylamine) and NDEA (N-nitrosodiethylamine) alone or their combination over a wide range of concentrations (1–100 mg/l). Results showed that the background level of N7-MeG in liver of control fish was 7.89±1.38 μmol/mol of guanine, while N7-EtG was detectable in most of the control fish with a range of 0.05–0.19 μmol/mol of guanine. N7-MeG and N7-EtG were significantly induced by NDMA and NDEA respectively, at a concentration as low as 1 mg/l and increased in a dose-dependent manner. Taken together, this LC-MS/MS assay provides the sensitivity and high throughput required to evaluate the extent of alkylated DNA lesions in small animal models of cancer induced by alkylating agents. PMID:17134374
Baglai, Anna; Gargano, Andrea F G; Jordens, Jan; Mengerink, Ynze; Honing, Maarten; van der Wal, Sjoerd; Schoenmakers, Peter J
2017-12-29
Recent advancements in separation science have resulted in the commercialization of multidimensional separation systems that provide higher peak capacities and, hence, enable a more-detailed characterization of complex mixtures. In particular, two powerful analytical tools are increasingly used by analytical scientists, namely online comprehensive two-dimensional liquid chromatography (LC×LC, having a second-dimension separation in the liquid phase) and liquid chromatography-ion mobility-spectrometry (LC-IMS, second dimension separation in the gas phase). The goal of the current study was a general assessment of the liquid-chromatography-trapped-ion-mobility-mass spectrometry (LC-TIMS-MS) and comprehensive two-dimensional liquid chromatography-mass spectrometry (LC×LC-MS) platforms for untargeted lipid mapping in human plasma. For the first time trapped-ion-mobility spectrometry (TIMS) was employed for the separation of the major lipid classes and ion-mobility-derived collision-cross-section values were determined for a number of lipid standards. The general effects of a number of influencing parameters have been inspected and possible directions for improvements are discussed. We aimed to provide a general indication and practical guidelines for the analyst to choose an efficient multidimensional separation platform according to the particular requirements of the application. Analysis time, orthogonality, peak capacity, and an indicative measure for the resolving power are discussed as main characteristics for multidimensional separation systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick
2015-01-01
This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.
Touriño, Sonia; Fuguet, Elisabet; Jáuregui, Olga; Saura-Calixto, Fulgencio; Cascante, Marta; Torres, Josep Lluís
2008-11-01
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.
Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko
2017-07-28
High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.
Yang, Yang; Zhang, Yongmin; Wei, Chong; Li, Jing; Sun, Wenji
2018-09-01
Silver ion chromatography, utilizing columns packed with silver ions bonded to silica gel, has proved to be an invaluable technique for the analysis of some positional isomers. In this work, silver ion chromatography by combination with online heart-cutting LC-LC technique for the preparative separation of two sesquiterpenes positional isomers from a natural product was investigated. On the basis of the evaluation that silver ion content impacts on the separation, the laboratory-made silver ion columns, utilizing silica gel impregnated with 15% silver nitrate as column packing materials, were used for peak resolution improvement of these two isomers and the preparative separation of them in heart-cutting LC-LC. The relationship among the maximal sample load, flow rate and peak resolution in the silver ion column were optimized, and the performance of the silver ion column was compared with conventional C 18 column and silica gel column. Based on the developed chromatographic conditions, online heart-cutting LC-LC chromatographic separation system in combination with a silica gel column and a silver ion column that was applied to preparative separation of these two isomers from a traditional Chinese medicine, Inula racemosa Hook.f., was established. The results showed that the online heart-cutting LC-LC technique by combination of a silica gel column and a silver ion column for the preparative separation of these two positional isomers from this natural plant was superior to the preparative separation performed on a single-column system with C 18 column or silica gel column. Copyright © 2018 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Cultures of Fusarium sporotrichioides were extracted and subjected to evaluation by high performance liquid chromatography – tandem mass spectrometry (LC-MS/MS). Along with the expected T-2 and HT-2 toxins, compounds 162 m/z higher than the toxins were observed. Fragmentation behavior of the larger ...
Tryptic digests of human serum albumin (HSA) and human lung epithelial cell lysates were used as test samples in a novel proteomics study. Peptides were separated and analyzed using 2D-nano-LC/MSMS with strong cation exchange (SCX) and reverse phase (RP) chromatography and contin...
Identification of peptide features in precursor spectra using Hardklör and Krönik
Hoopmann, Michael R.; MacCoss, Michael J.; Moritz, Robert L.
2013-01-01
Hardklör and Krönik are software tools for feature detection and data reduction of high resolution mass spectra. Hardklör is used to reduce peptide isotope distributions to a single monoisotopic mass and charge state, and can deconvolve overlapping peptide isotope distributions. Krönik filters, validates, and summarizes peptide features identified with Hardklör from data obtained during liquid chromatography mass spectrometry (LC-MS). Both software tools contain a simple user interface and can be run from nearly any desktop computer. These tools are freely available from http://proteome.gs.washington.edu/software/hardklor. PMID:22389013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klein, Adam
2015-01-01
This thesis presents work on advancements and applications of methodology for the analysis of biological samples using mass spectrometry. Included in this work are improvements to chemical cross-linking mass spectrometry (CXMS) for the study of protein structures and mass spectrometry imaging and quantitative analysis to study plant metabolites. Applications include using matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) to further explore metabolic heterogeneity in plant tissues and chemical interactions at the interface between plants and pests. Additional work was focused on developing liquid chromatography-mass spectrometry (LC-MS) methods to investigate metabolites associated with plant-pest interactions.
A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.
Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A
2017-01-15
The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Krishnan, Karthik; Aono, Masakazu; Tsuruoka, Tohru
2016-07-01
Resistive switching characteristics and conducting filament formation dynamics in solid polymer electrolyte (SPE) based planar-type atomic switches, with opposing active Ag and inert Pt electrodes, have been investigated by optimizing the device configuration and experimental parameters such as the gap distance between the electrodes, the salt inclusion in the polymer matrix, and the compliance current applied in current-voltage measurements. The high ionic conductivities of SPE enabled us to make scanning electron microscopy observations of the filament formation processes in the sub-micrometer to micrometer ranges. It was found that switching behaviour and filament growth morphology depend strongly on several kinetic factors, such as the redox reaction rate at the electrode-polymer interfaces, ion mobility in the polymer matrix, electric field strength, and the reduction sites for precipitation. Different filament formations, resulting from unidirectional and dendritic growth behaviours, can be controlled by tuning specified parameters, which in turn improves the stability and performance of SPE-based devices.Resistive switching characteristics and conducting filament formation dynamics in solid polymer electrolyte (SPE) based planar-type atomic switches, with opposing active Ag and inert Pt electrodes, have been investigated by optimizing the device configuration and experimental parameters such as the gap distance between the electrodes, the salt inclusion in the polymer matrix, and the compliance current applied in current-voltage measurements. The high ionic conductivities of SPE enabled us to make scanning electron microscopy observations of the filament formation processes in the sub-micrometer to micrometer ranges. It was found that switching behaviour and filament growth morphology depend strongly on several kinetic factors, such as the redox reaction rate at the electrode-polymer interfaces, ion mobility in the polymer matrix, electric field strength, and the reduction sites for precipitation. Different filament formations, resulting from unidirectional and dendritic growth behaviours, can be controlled by tuning specified parameters, which in turn improves the stability and performance of SPE-based devices. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00569a
Zhou, Neng-Zhi; Liu, Ping; Su, Xiao-Chuan; Liao, Yan-Hua; Lei, Ning-Sheng; Liang, Yong-Hong; Zhou, Shao-Huan; Lin, Wen-Si; Chen, Jie; Feng, Yu-Qi; Tang, Yang
2017-06-01
Aflatoxins (AFs) are highly toxic, mutagenic, carcinogenic, and teratogenic secondary metabolites produced by the toxigenic fungi Aspergillus flavus and Aspergillus parasiticus. AFs tend to contaminate a wide range of foods which is a serious and recurring food safety problem worldwide. Currently, immunoaffinity chromatography (IAC) has become the most conventional sample clean-up method for determining AFs in foodstuffs. However, IAC method is limited in the large-scale food analysis because it requires the use of expensive disposable cartridges and the IA procedure is time-consuming. Herein, to achieve the cost-effective determination of AFs in edible oils, we developed a promising solid-phase extraction (SPE) method based on commercially available humic acid-bonded silica (HAS) sorbent, followed by high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) analysis. In HAS-SPE, AFs can be captured by the HAS sorbent with both hydrophobic and hydrophilic interactions, whereas the oil matrix was captured only with the hydrophobic interactions. The oil matrix can be sufficiently washed off with isopropanol, while the AFs were still retained on the SPE packing, thus achieving selective extraction of AFs and clean-up of oil matrices. Under the optimal conditions of HAS-SPE, satisfactory recoveries ranging from 82% to 106% for four AFs (B 1 , B 2 , G 1 , and G 2 ) were achieved in various oil matrices, containing blended oil, tea oil, rapeseed oil, peanut oil, sunflower seed oil, corn oil, blended olive oil, rice oil, soybean oil, and sesame oil. Only minor matrix effects ranging from 99% to 105% for four AFs were observed. Moreover, the LODs of AFs between 0.012 and 0.035 μg/kg completely meet the regulatory levels fixed by the EU, China or other countries. The methodology was further validated for assaying the naturally contaminated peanut oils, and consistent results between the HAS-SPE and the referenced IAC were obtained. In addition, HAS-SPE can directly treat diluted oil sample without liquid-liquid extraction and is automatable, thus making it simple and convenient for the large-scale determination of AFs in edible oils. Using this method, we successfully detected four AFs in the naturally contaminated peanut oils, which is, to the best of our knowledge, the first report about the determination of AFs in edible oils using HA-based SPE. Copyright © 2017 Elsevier B.V. All rights reserved.
Herrera-Herrera, Antonio V; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel A; Herrero, Miguel; Cifuentes, Alejandro
2011-10-21
The present work describes a method based on solid-phase extraction (SPE) and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the simultaneous determination of three quinolones (pipemidic acid, oxolinic acid and flumequine) and twelve fluoroquinolones (marbofloxacin, fleroxacin, pefloxacin, levofloxacin, norfloxacin, ciprofloxacin, enrofloxacin, danofloxacin, lomefloxacin, difloxacin, sarafloxacin, and moxifloxacin) in different infant and young children powdered milks. After suitable deproteination of the reconstituted powdered samples, a SPE procedure was developed providing recovery values higher than 84% (RSDs lower than 13%) for all the analytes, with limits of detection between 0.04 and 0.52 μg/kg. UPLC-MS/MS analyses were carried out in less than 10 min. Sixteen infant and young children powdered milk samples of different origin, type and composition bought at Spanish markets were analyzed. Residues of the selected antibiotics were not detected in any of the analyzed samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Ng, Nyuk Ting; Sanagi, Mohd Marsin; Wan Ibrahim, Wan Nazihah; Wan Ibrahim, Wan Aini
2017-05-01
Agarose-chitosan-immobilized octadecylsilyl-silica (C 18 ) film micro-solid phase extraction (μSPE) was developed and applied for the determination of phenanthrene (PHE) and pyrene (PYR) in chrysanthemum tea samples using high performance liquid chromatography-ultraviolet detection (HPLC-UV). The film of blended agarose and chitosan allows good dispersion of C 18 , prevents the leaching of C 18 during application and enhances the film mechanical stability. Important μSPE parameters were optimized including amount of sorbent loading, extraction time, desorption solvent and desorption time. The matrix match calibration curves showed good linearity (r⩾0.994) over a concentration range of 1-500ppb. Under the optimized conditions, the proposed method showed good limits of detection (0.549-0.673ppb), good analyte recoveries (100.8-105.99%) and good reproducibilities (RSDs⩽13.53%, n=3) with preconcentration factors of 4 and 72 for PHE and PYR, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.
Shen, Qing; Dai, Zhiyuan; Huang, Yao-Wen; Cheung, Hon-Yeung
2016-08-15
Dried seahorse is a precious raw food material for cooking soups. In this study, a lipidomics strategy using the techniques of solid-phase extraction (SPE) and hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-QTOF/MS) was developed for extraction, visualization, and quantification of phospholipids in dried seahorses. The parameters of SPE were optimized, and 1 mL of sample and chloroform/methanol (1:2, v/v) were found to be the best loading volume and eluting solvent, respectively. Afterwards, each phospholipid class was successfully separated on a HILIC column and analyzed by mass spectrometry. A total of 50 phospholipid molecular species were identified and determined, including 15 phosphatidylcholines (PCs), 14 phosphatidylethanolamines (PEs), 12 phosphatidylinositols (PIs) and 9 phosphatidylserines (PSs). In comparison to previously methods, this strategy was robust and efficient in extraction, characterization, and determination of phospholipids. The dried seahorse was found to contain large amounts of polyunsaturated fatty acyl phospholipids which are beneficial to human health. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mozaner Bordin, Dayanne C; Alves, Marcela N R; Cabrices, Oscar G; de Campos, Eduardo G; De Martinis, Bruno Spinosa
2014-01-01
Drug abuse by pregnant women is considered a serious public health problem worldwide. Meconium is the first excretion in newborns and has been used as an alternative matrix to evaluate in utero drug exposure. Solid phase extraction (SPE) is widely employed to prepare and clean up samples in the field of forensic analysis. Most SPE products require large volumes of solvent, which culminates in longer sample processing times and increased cost per sample. Disposable pipette extraction (DPX) tips have been used as an alternative to traditional SPE cartridges. They combine efficient and rapid extraction with reduced solvent consumption. The purpose of this study was to develop and validate a method to determine nicotine, cotinine, cocaine, benzoylecgonine, cocaethylene and methyl ester anhydroecgonine in meconium using DPX and gas chromatography-mass spectrometry (GC-MS). Validation results indicated that extraction efficiency ranged 50-98%, accuracy 92-106%, intra-assay precision 4-12% and inter-assay precision 6-12%. Linear calibration curves resulted in R(2) values >0.99, limits of detection ranged from 2.5 to 15 ng/g and the limit of quantitation from 10 to 20 ng/g. The DPX-GC-MS method was shown to selectively analyze trace concentrations of drugs in meconium samples. Finally, the developed and validated method was applied to 50 meconium samples.
Zhang, Pingping; Lian, Kaoqi; Wu, Xiaoli; Yao, Min; Lu, Xin; Kang, Weijun; Jiang, Lingling
2014-04-04
Determining the level of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG), an oxidative DNA damage biomarker, is vital to the study of clinical pathogenesis and drug toxicity. The principal limitation of capillary electrophoresis (CE) with UV detection is its low sensitivity. To overcome this shortcoming, we developed a micellar electrokinetic capillary chromatography (MEKC) with solid-phase extraction (SPE) for urinary 8-OHdG analysis. The sensitivity of MEKC-UV was improved using a reasonable UV system, injection mode, and SPE. The parameters affecting MEKC and SPE were also optimized. The calibration curve was linear within the range from 1 to 500 μg L(-1). The limits of detection and quantification were 0.27 μg L(-1) and 0.82 μg L(-1), respectively. Interday and intraday precision were both <5.6%. The recovery of 8-OHdG in urine ranged from 94.5% to 103.2%. This method was used to measure urinary 8-OHdG from eight normal children, eight newly diagnosed leukemic children, and eight leukemic children undergoing chemotherapy. The results show that the proposed method can be used to assess oxidative stress in patients and the side effects of chemotherapeutic drugs by measuring urinary 8-OHdG. Copyright © 2014 Elsevier B.V. All rights reserved.
La Barbera, Giorgia; Capriotti, Anna Laura; Cavaliere, Chiara; Foglia, Patrizia; Montone, Carmela Maria; Zenezini Chiozzi, Riccardo; Laganà, Aldo
2017-01-01
Mycotoxins can contaminate various food commodities, including cereals. Moreover, mycotoxins of different classes can co-contaminate food, increasing human health risk. Several analytical methods have been published in the literature dealing with mycotoxins determination in cereals. Nevertheless, in the present work, the aim was to propose an easy and effective system for the extraction of six of the main mycotoxins from corn meal and durum wheat flour, i.e., the main four aflatoxins, ochratoxin A, and the mycoestrogen zearalenone. The developed method exploited magnetic solid phase extraction (SPE), a technique that is attracting an increasing interest as an alternative to classical SPE. Therefore, the use of magnetic graphitized carbon black as a suitable extracting material was tested. The same magnetic material proved to be effective in the extraction of mycoestrogens from milk, but has never been applied to complex matrices as cereals. Ultra high–performance liquid chromatography tandem mass spectrometry was used for detection. Recoveries were >60% in both cereals, even if the matrix effects were not negligible. The limits of quantification of the method results were comparable to those obtained by other two magnetic SPE-based methods applied to cereals, which were limited to one or two mycotoxins, whereas in this work the investigated mycotoxins belonged to three different chemical classes. PMID:28430148
Ding, Yiran; Huang, Yun; Zhao, Tingting; Cai, Qian; Luo, Yu; Huang, Bin; Zhang, Yuxia; Pan, Xuejun
2014-06-01
A method for the determination of five representative organic UV filters: ethylhexyl methoxycinnamate (EHMC), benzophenone-3 (BP-3), 4-methylbenzylidene camphor (4-MBC), octocrylene (OC), homosalate (HMS) in water was investigated. The method was ased on derivatization, solid phase extraction (SPE), followed by determination with gas chromatography-mass spectrometry (GC-MS). The variables involved in the derivatization of BP-3 and HMS were optimized, and SPE conditions were studied. For derivatization, 100 microL N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) was used as derivatization reagent and reacted with BP-3 and HMS at 100 degrees C for 100 min. For SPE, the pH value of water sample was adjusted to 3-5. The Oasis HLB cartridges were employed and the solution of ethyl acetate and dichloromethane (1 : 1, v/v) was used as the eluting solvent, and good recoveries of the target compounds were obtained. The limits of detection (LODs) and the limits of quantification (LOQs) for the five target compounds in water samples were 0.5-1.2 ng/L and 1.4-4.0 ng/L, respectively. The recoveries of spiked water samples were 87.85%-102.34% with good repeatability and reproducibility (RSD < 5%, n = 3) for all the target compounds. Finally, the validated method was applied to analysis the representative UV filters in water samples collected from a wastewater treatment plant in Kunming city of Yunnan province.
Barbera, Giorgia La; Capriotti, Anna Laura; Cavaliere, Chiara; Foglia, Patrizia; Montone, Carmela Maria; Chiozzi, Riccardo Zenezini; Laganà, Aldo
2017-04-21
Mycotoxins can contaminate various food commodities, including cereals. Moreover, mycotoxins of different classes can co-contaminate food, increasing human health risk. Several analytical methods have been published in the literature dealing with mycotoxins determination in cereals. Nevertheless, in the present work, the aim was to propose an easy and effective system for the extraction of six of the main mycotoxins from corn meal and durum wheat flour, i.e., the main four aflatoxins, ochratoxin A, and the mycoestrogen zearalenone. The developed method exploited magnetic solid phase extraction (SPE), a technique that is attracting an increasing interest as an alternative to classical SPE. Therefore, the use of magnetic graphitized carbon black as a suitable extracting material was tested. The same magnetic material proved to be effective in the extraction of mycoestrogens from milk, but has never been applied to complex matrices as cereals. Ultra high-performance liquid chromatography tandem mass spectrometry was used for detection. Recoveries were >60% in both cereals, even if the matrix effects were not negligible. The limits of quantification of the method results were comparable to those obtained by other two magnetic SPE-based methods applied to cereals, which were limited to one or two mycotoxins, whereas in this work the investigated mycotoxins belonged to three different chemical classes.
Zhang, Weiya; Wan, Xin; Li, Lixia; Wang, Chengyun; Jin, Shupei; Xing, Jun
2014-10-01
The short chain chlorinated paraffins (SCCPs) are the additives frequently used in the leather production in China, but they have been put into the list of forbidden chemicals issued by European Union recently. In fact, there is not a commonly recognized method for the determination of the SCCPs in the leather products due to the serious matrix interferences from the leather products and the complex chemical structures of the SCCPs. A method of solid phase extraction coupled with gas chromatography-mass spectrometry (SPE-GC-MS) was established for the determination of the SCCPs in the leather products after the optimization of the SPE conditions. It was found that the interferences from the leather products were thor- oughly separated from the analyte of the SCCPs on a home-made solid phase extraction (SPE) column filled with silica packing while eluted with a mixed solvent of n-hexane-methylene chloride (2:1, v/v). With this method, the recoveries for the SCCPs spiked in the real leather samples varied from 90.47% to 99.00% with the relative standard deviations (RSDs) less than 6.7%, and the limits of detection (LODs) were between 0.069 and 0.110 mg/kg. This method is suitable for qualitative and quantitative analysis of SCCPs in the leather products.
Podhorniak, Lynda V; Kamel, Alaa; Rains, Diane M
2010-05-26
A rapid multiresidue method that captures residues of the insecticide formetanate hydrochloride (FHCl) in selected fruits is described. The method was used to provide residue data for dietary exposure determinations of FHCl. Using an acetonitrile extraction with a dispersive cleanup based on AOAC International method 2007.01, also known as QuEChERS, which was further modified and streamlined, thousands of samples were successfully analyzed for FHCl residues. FHCl levels were determined both by liquid chromatography-single-stage mass spectrometry (LC-MS) and ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (LC-MS/MS). The target limit of detection (LOD) and the limit of quantitation (LOQ) achieved for FHCl were 3.33 and 10 ng/g, respectively, with LC-MS and 0.1 and 0.3 ng/g, respectively, with LC-MS/MS. Recoveries at these previously unpublished levels ranged from 95 to 109%. A set of 20-40 samples can be prepared in one working day by two chemists.
Analysis of triacylglycerols on porous graphitic carbon by high temperature liquid chromatography.
Merelli, Bérangère; De Person, Marine; Favetta, Patrick; Lafosse, Michel
2007-07-20
The retention behaviour of several triacylglycerols (TAGs) and fats on Hypercarb, a porous graphitic carbon column (PGC), was investigated in liquid chromatography (LC) under isocratic elution mode with an evaporative light scattering detector (ELSD). Mixtures of chloroform/isopropanol were selected as mobile phase for a suitable retention time to study the influence of temperature. The retention was different between PGC and non-aqueous reversed phase liquid chromatography (NARP-LC) on octadecyl phase. The retention of TAGs was investigated in the interval 30-70 degrees C. Retention was greatly affected by temperature: it decreases as the column temperature increases. Selectivity of TAGs was also slightly influenced by the temperature. Moreover, this chromatographic method is compatible with a mass spectrometer (MS) detector by using atmospheric pressure chemical ionisation (APCI): same fingerprints of cocoa butter and shea butter were obtained with LC-ELSD and LC-APCI-MS. These preliminary results showed that the PGC column could be suitable to separate quickly triacylglycerols in high temperature conditions coupled with ELSD or MS detector.
NASA Astrophysics Data System (ADS)
Gotjen, Henry G.; Kolacz, Jakub; Myers, Jason D.; Frantz, Jesse A.; Bekele, Robel Y.; Naciri, Jawad; Spillmann, Christopher M.
2018-02-01
A non-mechanical refractive laser beam steering device has been developed to provide continuous, two-dimensional steering of infrared beams. The technology implements a dielectric slab waveguide architecture with a liquid crystal (LC) cladding. With voltage control, the birefringence of the LC can be leveraged to tune the effective index of the waveguide under an electrode. With a clever prism electrode design a beam coupled into the waveguide can be deflected continuously in two dimensions as it is coupled out into free space. The optical interaction with LC in this beamsteerer is unique from typical LC applications: only the thin layer of LC (100s of nm) near the alignment interface interacts with the beam's evanescent field. Whereas most LC interactions take place over short path lengths (microns) in the bulk of the material, here we can interrogate the behavior of LC near the alignment interface over long path lengths (centimeters). In this work the beamsteerer is leveraged as a tool to study the behavior of LC near the alignment layer in contrast to the bulk material. We find that scattering is substantially decreased near the alignment interface due to the influence of the surface anchoring energy to suppress thermal fluctuations. By tracking the position of the deflected beam with a high speed camera, we measure response times of the LC near the interface in off-to-on switching ( ms) and on-to-off switching ( 100ms). Combined, this work will provide a path for improved alignment techniques, greater optical throughput, and faster response times in this unique approach to non-mechanical beamsteering.
Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C
2017-11-10
An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real injection profiles obtained from 2D-LC interface valves are used to simulate the introduction of samples into the 2 D column. These profiles are highly asymmetric - simulation using simple rectangular pulses leads to peak widths that are far too narrow under many conditions. We believe the simulation approach developed here will be useful for addressing practical questions in the development of 2D-LC methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Chiang, Wen-Chieh; Chen, Chao-Yu; Lee, Ting-Chen; Lee, Hui-Ling; Lin, Yu-Wen
2015-01-01
Recently, the International Agency for Research on cancer classified outdoor air pollution and particulate matter from outdoor air pollution as carcinogenic to humans (IARC Group 1), based on sufficient evidence of carcinogenicity in humans and experimental animals and strong mechanistic evidence. In particular, a wide variety of volatile organic compounds (VOCs) are volatized or released into the atmosphere and can become ubiquitous, as they originate from many different natural and anthropogenic sources, such as paints, pesticides, vehicle exhausts, cooking fumes, and tobacco smoke. Humans may be exposed to VOCs through inhalation, ingestion, or dermal contact, which may increase the risk of leukemia, birth defects, neurocognitive impairment, and cancer. Therefore, the focus of this study was the development of a simple, effective and rapid sample preparation method for the simultaneous determination of seven metabolites (6 mercaptic acids+t,t-muconic acid) derived from five VOCs (acrylamide, 1,3-butadiene, acrylonitrile, benzene, and xylene) in human urine by using automated on-line solid-phase extraction (SPE) coupled with liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS). An aliquot of each diluted urinary sample was directly injected into an autosampler through a trap column to reduce contamination, and then the retained target compounds were eluted by back-flush mode into an analytical column for separation. Negative electrospray ionization tandem mass spectrometry was utilized for quantification. The coefficients of correlation (r(2)) for the calibration curves were greater than 0.995. Reproducibility was assessed by the precision and accuracy of intra-day and inter-day precision, which showed results for coefficient of variation (CV) that were low 0.9 to 6.6% and 3.7 to 8.5%, respectively, and results for recovery that ranged from 90.8 to 108.9% and 92.1 to 107.7%, respectively. The limits of detection (LOD) and limits of quantification (LOQ) were determined to within 0.010 to 0.769 ng mL(-1) and 0.033 to 2.564 ng mL(-1) in this study. A stability study test included 3 freeze/thaw cycles during short-term storage at room temperature for 36 h and long-term storage at -20 °C for 1 month, and the CV (coefficient of variation) showed less than 8.4, 7.4 and 9.7%, respectively. To the best of our knowledge, this is the first study to provide simple, small injection volumes (40 µL) and a rapid LC-MS/MS method combined with an on-line SPE step for the simultaneous detection, identification, and quantification of seven metabolites derived from five VOCs in human urine for evaluation of the future risk of human exposure to volatile organic compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Liu, Lei; Liu, Kang-Ning; Wen, Ya-Bin; Zhang, Han-Wen; Lu, Ya-Xin; Yin, Zheng
2012-04-15
A fully automated on-line solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with diode array detection (DAD) method was developed for determination of bavachinin in mouse plasma. Analytical process was performed on two reversed-phase columns (SPE cartridge and analytical column) connected via a Valco 6-port switching valve. Plasma samples (10 μL) were injected directly onto a C18 SPE cartridge (MF Ph-1 C18, 10 mm × 4 mm, 5 μm) and the biological matrix was washed out for 2 min with the loading solvent (5 mM NaH(2)PO(4) buffer, pH 3.5) at a flow rate of 1 mL/min. By rotation of the switching valve, bavachinin was eluted from the SPE cartridge in the back-flush mode and transferred to the analytical column (Venusil MP C18, 4.6 mm × 150 mm, 5 μm) by the chromatographic mobile phase consisted of acetonitrile-5mM NaH(2)PO(4) buffer 65/35 (v/v, pH 3.5) at a flow rate of 1 mL/min. The complete cycle of the on-line SPE purification and chromatographic separation of the analyte was 13 min with UV detection performed at 236 nm. Calibration curve with good linearity (r=0.9997) was obtained in the range of 20-4000 ng/mL in mouse plasma. The intra-day and inter-day precisions (RSD) of bavachinin were in the range of 0.20-2.32% and the accuracies were between 98.47% and 102.95%. The lower limit of quantification (LLOQ) of the assay was 20 ng/mL. In conclusion, the established automated on-line SPE-HPLC-DAD method demonstrated good performance in terms of linearity, specificity, detection and quantification limits, precision and accuracy, and was successfully utilized to quantify bavachinin in mouse plasma to support the pharmacokinetic (PK) studies. The PK properties of bavachinin were characterized as rapid oral absorption, high clearance, and poor absolute bioavailability. Copyright © 2012. Published by Elsevier B.V.
Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria
2016-07-01
A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.
Sun, Meng; Ren, Jing; Du, Hui; Zhang, Yanmin; Zhang, Jie; Wang, Sicen; He, Langchong
2010-10-15
We have developed an online analytical method that combines A431 cell membrane chromatography (A431/CMC) with high performance liquid chromatography and mass spectrometry (LC/MS) for identifying active components from Radix Caulophylli acting on human EGFR. Retention fractions on A431/CMC model were captured onto an enrichment column and the components were directly analyzed by combining a 10-port column switcher with an LC/MS system for separation and preliminary identification. Using Sorafenib tosylate as a positive control, taspine and caulophine from Radix Caulophylli were identified as the active molecules which could act on the EGFR. This A431/CMC-online-LC/MS method can be applied for screening active components acting on EGFR from traditional Chinese medicines exemplified by Radix Caulophylli and will be of great utility in drug discovery using natural medicinal herbs as a source of novel compounds. Copyright © 2010 Elsevier B.V. All rights reserved.
Siu, S O; Lam, Maggie P Y; Lau, Edward; Yeung, William S B; Cox, David M; Chu, Ivan K
2010-01-01
Although reverse-phase liquid chromatography (RP-LC) is a common technique for peptide separation in shotgun proteomics and glycoproteomics, it often provides unsatisfactory results for the analysis of glycopeptides and glycans. This bias against glycopeptides makes it difficult to study glycoproteins. By coupling mass spectrometry (MS) with a combination of RP-LC and normal-phase (NP)-LC as an integrated front-end separation system, we demonstrate that effective identification and characterization of both peptides and glycopeptides mixtures, and their constituent glycan structures, can be achieved from a single sample injection event.
Bruggink, C.; Koeleman, C.; Barreto, V.; Lui, Y.; Pohl, C.; Ingendoh, A.; Wuhrer, M.; Hokke, C.; Deelder, A.
2007-01-01
High-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) is an established technique for selective separation and analysis of underivatized carbohydrates. The miniaturization of chromatographic techniques by means of capillary columns, and on-line coupling to mass spectrometry are critical to the further development of glycan analysis methods that are compatible with the current requirements in clinical settings. A system has been developed based on the Dionex BioLC equipped with a microbore gradient pump with PEEK flow splitter, a FAMOS micro autosampler, a modified electrochemical cell for on-line capillary PAD, and a capillary column (380 μm i.d.) packed with a new type of anion-exchange resin. This system operates with sensitivity in the low femtomol range. In addition, an on-line capillary desalter has been developed to allow direct coupling to the Bruker Esquire 3000 ion-trap mass spectrometer with electrospray ionization interface (ESI-IT-MS). Both systems have been evaluated using oligosaccharide standards as well as urine samples exhibiting various lysosomal oligosaccharide storage diseases. Initial data indicate that the robust and selective anion-exchange system, in combination with ESI-IT-MS for structure confirmation and analysis, provides a powerful platform that complements existing nano/capillary LC-MS methods for analytical determination of oligosaccharides in biological matrices.
Yi, Xinzhu; Bayen, Stéphane; Kelly, Barry C; Li, Xu; Zhou, Zhi
2015-12-01
A solid-phase extraction/liquid chromatography/electrospray ionization/multi-stage mass spectrometry (SPE-LC-ESI-MS/MS) method was optimized in this study for sensitive and simultaneous detection of multiple antibiotics in urban surface waters and soils. Among the seven classes of tested antibiotics, extraction efficiencies of macrolides, lincosamide, chloramphenicol, and polyether antibiotics were significantly improved under optimized sample extraction pH. Instead of only using acidic extraction in many existing studies, the results indicated that antibiotics with low pK a values (<7) were extracted more efficiently under acidic conditions and antibiotics with high pK a values (>7) were extracted more efficiently under neutral conditions. The effects of pH were more obvious on polar compounds than those on non-polar compounds. Optimization of extraction pH resulted in significantly improved sample recovery and better detection limits. Compared with reported values in the literature, the average reduction of minimal detection limits obtained in this study was 87.6% in surface waters (0.06-2.28 ng/L) and 67.1% in soils (0.01-18.16 ng/g dry wt). This method was subsequently applied to detect antibiotics in environmental samples in a heavily populated urban city, and macrolides, sulfonamides, and lincomycin were frequently detected. Antibiotics with highest detected concentrations were sulfamethazine (82.5 ng/L) in surface waters and erythromycin (6.6 ng/g dry wt) in soils. The optimized sample extraction strategy can be used to improve the detection of a variety of antibiotics in environmental surface waters and soils.
Rodrigues, M A; Reis, M P; Mateus, M C
2013-11-01
Microcystins (MCs) are toxins produced by cyanobacteria which are common organisms in the phytoplankton of eutrophic lakes, rivers and freshwater reservoirs. In the present work, a novel method of liquid chromatography-electrospray ion trap tandem mass spectrometry (LC/ESI/Ion trap-MS/MS), operated in the negative ionization mode, was developed for the analysis of these cyanotoxins. The method was applied to determine the amounts of total microcystins-LR, -YR and -RR in two water reservoirs in Southern Portugal, namely Alqueva and Beliche. A total of 30 water samples were analysed along 2011. Solid phase extraction (SPE) was used for sample cleaning-up and analyte enrichment. The extracted toxins were separated on a C18 column with a gradient of acetonitrile/water with 0.1% formic acid. Detection of microcystins was carried out using multiple reaction monitoring (MRM) in the negative polarity mode, as this method gave a higher selectivity. The MC-RR, YR and LR quantification limits were 17.9, 31.7 and 15.8 ng/L, respectively; quite below the limits recommended by WHO guidelines for drinking water (1 μg/L). Total MC highest concentrations were found in the warm months of June, July and September in Alqueva sampling sites, with concentrations of MC LR and RR ranging 17-344 and 25-212 ng/L, respectively, showing comparable results for MC-RR and LR and slightly lower concentration of MC-YR. Detected values for Beliche reservoir were below quantification limits. Copyright © 2013 Elsevier Ltd. All rights reserved.
Baker, David R; Kasprzyk-Hordern, Barbara
2011-11-04
Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds. Copyright © 2011 Elsevier B.V. All rights reserved.
Chen, Zhen-Zhen; Zhang, Dou-Sheng; Wang, Nan; Feng, Fang; Hu, Chang-Qin
2012-04-01
A novel qualitative analytical method by using two-dimensional chromatographic correlation spectroscopy techniques for recognizing impurity peaks of HPLC methods of quality control and LC-MS chromatographic system was established. The structures of major degradation products of ceftizoxime and cefdinir were identified by LC-MS and MassWorks application; the standard chromatographic and spectral data of the degradation impurities were obtained by high-performance liquid chromatography with diode array detection. The impurity peaks of two-dimensional chromatography were matched by comparison of spectra and calculating correlation coefficients. Peaks in chromatography can be identified accurately and rapidly in different chromatographic systems such as column and mobile phase changed. The method provides a new way and thought to identify the peaks in quality control of impurities without reference impurity substances.
Huang, Rongfu; Chen, Yuan; Gamal El-Din, Mohamed
2016-06-21
The separation of classical, aromatic, oxidized, and heteroatomic (sulfur-containing) naphthenic acid (NA) species from unprocessed and ozone-treated oil sands process-affected water (OSPW) was performed using silver-ion (Ag-ion) solid phase extraction (SPE) without the requirement of pre-methylation for NAs. OSPW samples before SPE and SPE fractions were characterized using ultra performance liquid chromatography ion mobility time-of-flight mass spectrometry (UPLC-IM-TOFMS) to corroborate the separation of distinct NA species. The mass spectrum identification applied a mass tolerance of ±1.5 mDa due to the mass errors of NAs were measured within this range, allowing the identification of O2S-NAs from O2-NAs. Moreover, separated NA species facilitated the tandem mass spectrometry (MS/MS) characterization of NA compounds due to the removal of matrix and a simplified composition. MS/MS results showed that classical, aromatic, oxidized, and sulfur-containing NA compounds were eluted into individual SPE fractions. Overall results indicated that the separation of NA species using Ag-ion SPE is a valuable method for extracting individual NA species that are of great interest for environmental toxicology and wastewater treatment research, to conduct species-specific studies. Furthermore, the separated NA species on the milligram level could be widely used as the standard materials for environmental monitoring of NAs from various contamination sites.
Musile, Giacomo; Cenci, Lucia; Piletska, Elena; Gottardo, Rossella; Bossi, Alessandra M; Bortolotti, Federica
2018-07-27
The aim of the present work was to develop a novel in-house mixed-mode SPE sorbent to be used for the HPLC-Ion TrapMS determination of 16 basic drugs in urine. By using a computational modelling, a virtual monomer library was screened identifying three suitable functional monomers, methacrylic acid (MAA), itaconic acid (IA) and 2-acrylamide-2-methylpropane sulfonic acid (AMPSA), respectively. Three different sorbents were then synthetized based on these monomers, and using as cross-linker trimethylolpropane trimethacrylate (TMPTMA). The sorbent characterization analyses brought to the selection of the AMPSA based phase. Using this novel in-house sorbent, a SPE-HPLC-Ion TrapMS method for drug analysis in urine was validated proving to be selective and accurate and showing a sensitivity adequate for toxicological urine analysis. The comparison of the in-house mixed-mode SPE sorbent with two analogous commercial mixed-mode SPE phases showed that the first one was better not only in terms of process efficiency, but also in terms of quality-price rate. To the best of our knowledge, this is the first time in which an in-house SPE procedure has been applied to the toxicological analysis of a complex matrix, such as urine. Copyright © 2018 Elsevier B.V. All rights reserved.
Yao, Li; Lv, Yin-Zhi; Zhang, Li-Juan; Liu, Wang-Rong; Zhao, Jian-Liang; Liu, You-Sheng; Zhang, Qian-Qian; Ying, Guang-Guo
2018-05-25
Personal care products (PCPs) are ubiquitous in aquatic environments owing to the continuous discharge of domestic wastewater from highly urbanized regions. These PCPs can be adsorbed by fish and thereafter usually enter the bile of the fish through biliary excretion. In this study, a sensitive method based on a combination of hybrid solvent precipitation and dispersive solid phase extraction (d-SPE) purification was developed to simultaneously extract and detect 24 PCPs, namely, 16 biocides, 4 synthetic musks, and 4 benzotriazoles, from fish bile. Hybrid precipitation on solid phase extraction (SPE) tubes was applied to remove phospholipids and proteins, and a d-SPE procedure was used for further purification. The extraction solvents for the hybrid precipitation/SPE tubes and d-SPE materials were optimized. The method performance for bile samples both with and without enzyme hydrolysis using β-glucuronidase/aryl-sulfatase were validated. The 24 PCPs in fish bile were spiked with standard concentrations of 10 ng/mL, 20 ng/mL, 100 ng/mL, and 200 ng/mL to evaluate recoveries, which ranged from 70 to 120% for 16, 16, 22, and 21 analytes with hydrolysis, respectively, and 70-120% for 14, 15, 23, and 23 analytes without hydrolysis, respectively. The quantification limits for target PCPs were in the range 0.26-7.38 ng/mL [excluding musk xylene (MX) and musk ketone (MK)] and 0.20-9.48 ng/mL (excluding MX and MK) for bile samples with and without enzyme hydrolysis, respectively. After enzyme hydrolysis, 12 PCPs were detected in bile from fish collected from the Yangtze River, with a maximum detected concentration of 460 ng/mL, for triclosan (TCS). The hydrolysis reaction indicated that high percentages of glucuronide and sulfate metabolites for some PCPs, i.e. four parabens and TCS, existed in the bile. Copyright © 2018 Elsevier B.V. All rights reserved.
Determination of fusaric acid in maize using molecularly imprinted SPE clean-up
USDA-ARS?s Scientific Manuscript database
A new liquid chromatography method to detect fusaric acid in maize is reported based on molecularly imprinted polymer solid phase extraction clean-up (MISPE) using mimic-templated molecularly-imprinted polymers. Picolinic acid was used as a toxin analog for imprinting polymers during a thermolytic s...
A solid-phase extraction (SPE) method was developed using 8 M urea to desorb and extract organochlorine pesticides (OCs) and polychlorinated biphenyls (PCBs) from avian serum for analysis by capillary gas chromatography with electron capture detection (GC-ECD). The analytes were ...
A rapid and sensitive method has been developed for the analysis of 48 human prescription active pharmaceutical ingredients (APIs) and 6 metabolites of interest, utilizing selective solid-phase extraction (SPE) and ultra performance liquid chromatography in combination with tripl...
An analytical method using solid phase extraction (SPE) and analysis by gas chromatography/mass spectrometry (GC/MS) was developed for the trace determination of a variety of agricultural pesticides and selected transformation products in large-volume high-elevation lake water sa...
Application of gas chromatography to analysis of spirit-based alcoholic beverages.
Wiśniewska, Paulina; Śliwińska, Magdalena; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek
2015-01-01
Spirit-based beverages are alcoholic drinks; their production processes are dependent on the type and origin of raw materials. The composition of this complex matrix is difficult to analyze, and scientists commonly choose gas chromatography techniques for this reason. With a wide selection of extraction methods and detectors it is possible to provide qualitative and quantitative analysis for many chemical compounds with various functional groups. This article describes different types of gas chromatography techniques and their most commonly used associated extraction techniques (e.g., LLE, SPME, SPE, SFE, and SBME) and detectors (MS, TOFMS, FID, ECD, NPD, AED, O or EPD). Additionally, brief characteristics of internationally popular spirit-based beverages and application of gas chromatography to the analysis of selected alcoholic drinks are presented.
Hercegová, Andrea; Dömötörová, Milena; Kruzlicová, Dása; Matisová, Eva
2006-05-01
Four sample preparation techniques were compared for the ultratrace analysis of pesticide residues in baby food: (a) modified Schenck's method based on ACN extraction with SPE cleaning; (b) quick, easy, cheap, effective, rugged, and safe (QuEChERS) method based on ACN extraction and dispersive SPE; (c) modified QuEChERS method which utilizes column-based SPE instead of dispersive SPE; and (d) matrix solid phase dispersion (MSPD). The methods were combined with fast gas chromatographic-mass spectrometric analysis. The effectiveness of clean-up of the final extract was determined by comparison of the chromatograms obtained. Time consumption, laboriousness, demands on glassware and working place, and consumption of chemicals, especially solvents, increase in the following order QuEChERS < modified QuEChERS < MSPD < modified Schenck's method. All methods offer satisfactory analytical characteristics at the concentration levels of 5, 10, and 100 microg/kg in terms of recoveries and repeatability. Recoveries obtained for the modified QuEChERS method were lower than for the original QuEChERS. In general the best LOQs were obtained for the modified Schenck's method. Modified QuEChERS method provides 21-72% better LOQs than the original method.
Schenck, F J; Calderon, L; Podhorniak, L V
1996-01-01
A rapid, multiresidue solid-phase extraction (SPE) technique for determination of organochlorine pesticide and polychlorinated biphenyl (PCB) residues in nonfatty fish was modified for use with fatty fish. In the modified procedures, samples are extracted with acetonitrile, and the extract is cleaned up with both C18 and Florisil SPE columns. Residues are determined by gas chromatography with electron capture detection. The original method was modified for use with fatty fish by reducing the amount of tissue extracted and by using an improved Florisil SPE cleanup. Recovery data are presented for 24 fortified organochlorine pesticide residues (0.12 ppm) and 3 fortified PCB residues (0.80 ppm) from flounder, bluefish, and shad samples, which contained 0.8, 5.4, and 22.6% fat, respectively. For the 3 types of fish, recoveries of 23 of 24 fortified organochlorine pesticide residues ranged from 55 to 129%, and recoveries of 3 fortified PCB residues ranged from 55 to 104%. There were no significant differences in recovery based on fish species and/or fat content for the majority of residues studied. This SPE method and the official AOAC method yielded comparable results for fish containing incurred organochlorine residues.
Sichilongo, Kwenga; Chinyama, Mompati; Massele, Amos; Vento, Sandro
2014-01-15
A contrast between the analytical performance characteristics using gas chromatography-mass spectrometry (GC-MS) liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-ultraviolet (LC-UV) detection for the determination of the antiretroviral drug (ARV) nevirapine (NVP) in fortified human plasma after QuEChERS extraction has been made. Analytical performance characteristics, i.e. linearities, instrument detection limits (IDLs), limits of quantitation (LOQs), method detection limits (MDLs), % mean recoveries and the corresponding relative standard deviations (%RSDs) were estimated using techniques above. Using GC-MS, the correlation coefficients (r(2)) were ≥0.990, which were deemed acceptable linearities. The MDLs ranged between 11.1-29.8μg/L and 13.7-36.0μg/L using helium and hydrogen carrier gases respectively. The LOQs ranged between 16.5-66.7μg/L and 28.4-98.7μg/L using helium and hydrogen carrier gases respectively with a % mean recovery of 83% and %RSD of 4.6%. Using LC-MS and LC-UV, the correlation coefficients (r(2)) were ≥0.990. The MDLs were ranged between 3.14 and 47.1μg/L. The LOQs ranged between 2.85 and 90.0μg/L respectively. The MDLs using GC-MS, LC-MS and LC-UV were below the therapeutic range for NVP in human plasma is considered to be between 2300μg/L (Cmin) and 8000μg/L (Cmax). This study also demonstrated that helium can be substituted with hydrogen which is relatively cheaper and easily obtainable even by use of a generator. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun
2017-10-13
A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Duxin; Schmitz, Oliver J
2015-01-01
The analysis of chemical constituents in Chinese herbal medicines (CHMs) is a challenge because of numerous compounds with various polarities and functional groups. Liquid chromatography coupled with quadrupole time-of-flight (QTOF) mass spectrometry (LC/MS) is of particular interest in the analysis of herbal components. One of the main attributes of QTOF that makes it an attractive analytical technique is its accurate mass measurement for both precursor and product ions. For the separation of CHMs, comprehensive two-dimensional chromatography (LCxLC) provides much higher resolving power than traditional one-dimensional separation. Therefore, a LCxLC-QTOF-MS system was developed and applied to the analysis of flavonoids and iridoid glycosides in aqueous extracts of Hedyotis diffusa (Rubiaceae). Shift gradient was applied in the two-dimensional separation in the LCxLC system to increase the orthogonality and effective peak distribution area of the analysis. Tentative identification of compounds was done by accurate mass interpretation and validation by UV spectrum. A clear classification of flavonol glycosides (FGs), acylated FGs, and iridoid glycosides (IGs) was shown in different regions of the LCxLC contour plot. In total, five FGs, four acylated FGs, and three IGs were tentatively identified. In addition, several novel flavonoids were found, which demonstrates that LCxLC-QTOF-MS detection also has great potential in herbal medicine analysis.
Recent trends in the impurity profile of pharmaceuticals
Pilaniya, Kavita; Chandrawanshi, Harish K.; Pilaniya, Urmila; Manchandani, Pooja; Jain, Pratishtha; Singh, Nitin
2010-01-01
Various regulatory authorities such as the International Conference on Harmonization (ICH), the United States Food and Drug administration (FDA), and the Canadian Drug and Health Agency (CDHA) are emphasizing on the purity requirements and the identification of impurities in Active Pharmaceutical Ingredients (APIs). The various sources of impurity in pharmaceutical products are — reagents, heavy metals, ligands, catalysts, other materials like filter aids, charcoal, and the like, degraded end products obtained during \\ after manufacturing of bulk drugs from hydrolysis, photolytic cleavage, oxidative degradation, decarboxylation, enantiomeric impurity, and so on. The different pharmacopoeias such as the British Pharmacopoeia, United State Pharmacopoeia, and Indian Pharmacopoeia are slowly incorporating limits to allowable levels of impurities present in APIs or formulations. Various methods are used to isolate and characterize impurities in pharmaceuticals, such as, capillary electrophoresis, electron paramagnetic resonance, gas–liquid chromatography, gravimetric analysis, high performance liquid chromatography, solid-phase extraction methods, liquid–liquid extraction method, Ultraviolet Spectrometry, infrared spectroscopy, supercritical fluid extraction column chromatography, mass spectrometry, Nuclear magnetic resonance (NMR) spectroscopy, and RAMAN spectroscopy. Among all hyphenated techniques, the most exploited techniques for impurity profiling of drugs are Liquid Chromatography (LC)-Mass Spectroscopy (MS), LC-NMR, LC-NMR-MS, GC-MS, and LC-MS. This reveals the need and scope of impurity profiling of drugs in pharmaceutical research. PMID:22247862
Yesil, Fatma; Suwa, Masayori; Tsukahara, Satoshi
2018-01-09
We constructed the apparatus to observe the Fréedericksz transition of liquid crystal in contact with water. The Fréedericksz transition is a distortion of nematic liquid crystals (LCs) induced by external fields. In the present system, sweeping homogeneous magnetic field was applied to the sample, and the distortion of the LC was visualized with a polarized light microscope with the crossed Nichols configuration. The anchoring energy (W AQ/LC ) at the aqueous phase/LC interface was measured in the presence of surfactant from the threshold magnetic field of the Fréedericksz transition. We studied two cationic surfactants: dodecyltrimethylammonium bromide and tetradecyltrimethylammonium bromide. A nematic LC, 4-cyano-4'-pentylbiphenyl (5CB), was examined, which was confined in a copper grid on an octadecyltrichlorosilane-treated microscope glass plate. Measured W AQ/LC were reproducible and showed consistence with the reported region for the water/LC interface. Interfacial excess of surfactants was also measured by the pendant drop method, and the relationship between the obtained W AQ/LC and the interfacial excess was investigated. Experiments showed that an increase in the anchoring energy depends on the surfactant and its interfacial excess. The region of the interfacial coverage, at which W AQ/LC increases, varied with the chain length of the surfactant. The measurement of the anchoring energy will provide new fundamental information on aqueous phase/LC interface.
Jian, Wenying; Edom, Richard W; Wang, Dai; Weng, Naidong; Zhang, Stanley Weihua
2013-03-05
Glycosylation is one of the most important post-translational modifications to mammalian proteins. Distribution of different glycoisoforms of certain proteins may reflect disease conditions and, therefore, can potentially be utilized as biomarkers. Apolipoprotein C3 (ApoC3) is one of the many plasma glycoproteins extensively studied for association with disease states. ApoC3 exists in three main glycoisoforms, including ApoC3-1 and ApoC3-2, which contain an O-linked carbohydrate moiety consisting of three and four monosaccharide residues, respectively, and ApoC3-0 that lacks the entire glycosylation chain. Changes in the ratio of different glycoisoforms of ApoC3 have been observed in pathological conditions such as kidney disease, liver disease, and diabetes. They may provide important information for diagnosis, prognosis, and evaluation of therapeutic response for metabolic conditions. In this current work, a liquid chromatography (LC)-high-resolution (HR) time-of-flight (TOF) mass spectrometry (MS) method was developed for relative quantitation of different glycoisoforms of intact ApoC3 in human plasma. The samples were processed using a solid-phase extraction (SPE) method and then subjected to LC-full scan HRMS analysis. Isotope peaks for each targeted glycoisoform at two charge states were extracted using a window of 50 mDa and integrated into a chromatographic peak. The peak area ratios of ApoC3-1/ApoC3-0 and ApoC3-2/ApoC3-0 were calculated and evaluated for assay performance. The results indicated that the ratio can be determined with excellent reproducibility in multiple subjects. It has also been observed that the ratios remained constant in plasma exposed to room temperature, freeze-thaw cycles, and long-term frozen storage. The method was applied in preliminary biomarker research of diabetes by analyzing plasma samples collected from normal, prediabetic, and diabetic subjects. Significant differences were revealed in the ApoC3-1/ApoC3-0 ratio and in the ApoC3-2/ApoC3-0 ratio among the three groups. The workflow of intact protein analysis using full scan HRMS established in this current work can be potentially extended to relative quantitation of other glycosylated proteins. To our best knowledge, this is the first time that a systematic approach of relative quantitation of targeted intact protein glycoisoforms using LC-MS has been established and utilized in biomarker research.
Dumont, Emmie; Ogra, Yasumitsu; Vanhaecke, Frank; Suzuki, Kazuo T; Cornelis, Rita
2006-03-01
Liquid chromatography (LC) hyphenated with both elemental and molecular mass spectrometry has been used for Se speciation in Se-enriched garlic. Different species were separated by ion-pair liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS) after hot-water extraction. They were identified by on-line reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry (RPLC-ESI-MS-MS). Se-methionine and Se-methylselenocysteine were determined by monitoring their product ions. Another compound, gamma-glutamyl-Se-methylselenocysteine, shown to be the most abundant form of Se in the garlic, was determined without any additional sample pre-treatment after extraction and without the need for a synthesized standard. Product ions for this dipeptide were detected by LC-ESI-MS-MS for three isotopes of Se-78 Se, 80Se: and 82Se. The method was extended to the species extracted during in-vitro gastrointestinal digestion. Because both Se-methylselenocysteine and gamma-glutamyl-Se-methylselenocysteine have anticarcinogenic properties, their extractability and stability during human digestion are very important. Garlic was also treated with saliva, to enable detection and analysis of species extracted during mastication. Detailed information on the extractability of selenium species by both simulated gastric and intestinal fluid are given, and variation of the distribution of Se among the different species with time is discussed. Although the main species in garlic is the dipeptide gamma-glutamyl-Se-methylselenocysteine, Se-methylselenocysteine is the main compound present in the extracts after treatment with gastrointestinal fluids. Two more, so far unknown compounds were observed in the chromatogram. The extracted species and their transformations were analysed by combining LC-ICP-MS and LC-ESI-MS-MS. In both the simulated gastric and intestinal digests, Se-methionine, Se-methylselenocysteine, and gamma-glutamyl-Se-methylselenocysteine could be determined by LC-ESI-MS-MS by measuring their typical product ions.
Sandra, Koen; Vanhoenacker, Gerd; Vandenheede, Isabel; Steenbeke, Mieke; Joseph, Maureen; Sandra, Pat
2016-10-01
Antibody-drug conjugates might be the magic bullets referred to by Paul Ehrlich over 100 years ago. Together with a huge therapeutic potential, these molecules come with a structural complexity that drives state-of-the-art chromatography and mass spectrometry to its limits. The use of multiple heart-cutting (mLC-LC) and comprehensive (LC×LC) multidimensional LC in combination with high resolution mass spectrometry for the characterization of the lysine conjugated antibody-drug conjugate ado-trastuzumab emtansine, commercialized as Kadcyla, is presented. By combining protein and peptide measurements, attributes such as drug loading, drug distribution and drug conjugation sites can be assessed in an elegant manner. Copyright © 2016 Elsevier B.V. All rights reserved.
High-temperature two-dimensional liquid chromatography of ethylene-vinylacetate copolymers.
Ginzburg, Anton; Macko, Tibor; Dolle, Volker; Brüll, Robert
2010-10-29
Temperature rising elution fractionation hyphenated to size exclusion chromatography (TREF×SEC) is a routine technique to determine the chemical heterogeneity of semicrystalline olefin copolymers. Its applicability is limited to well crystallizing samples. High-temperature two-dimensional liquid chromatography, HT 2D-LC, where the chromatographic separation by HPLC is hyphenated to SEC (HPLC×SEC) holds the promise to separate such materials irrespective of their crystallizability. A model blend consisting of ethylene-vinyl acetate (EVA) copolymers covering a broad range of chemical composition distribution including amorphous and semicrystalline copolymers and a polyethylene standard was separated by HT 2D-LC at 140°C. Both axes of the contour plot, i.e. the compositional axis from the HPLC and the molar mass axis from the SEC separation were calibrated for the first time. Therefore, a new approach to determine the void and dwell volume of the developed HT 2D-LC instrument was applied. The results from the HT 2D-LC separation are compared to those from a cross-fractionation (TREF×SEC) experiment. Copyright © 2010. Published by Elsevier B.V.
Forcisi, Sara; Moritz, Franco; Kanawati, Basem; Tziotis, Dimitrios; Lehmann, Rainer; Schmitt-Kopplin, Philippe
2013-05-31
The present review gives an introduction into the concept of metabolomics and provides an overview of the analytical tools applied in non-targeted metabolomics with a focus on liquid chromatography (LC). LC is a powerful analytical tool in the study of complex sample matrices. A further development and configuration employing Ultra-High Pressure Liquid Chromatography (UHPLC) is optimized to provide the largest known liquid chromatographic resolution and peak capacity. Reasonably UHPLC plays an important role in separation and consequent metabolite identification of complex molecular mixtures such as bio-fluids. The most sensitive detectors for these purposes are mass spectrometers. Almost any mass analyzer can be optimized to identify and quantify small pre-defined sets of targets; however, the number of analytes in metabolomics is far greater. Optimized protocols for quantification of large sets of targets may be rendered inapplicable. Results on small target set analyses on different sample matrices are easily comparable with each other. In non-targeted metabolomics there is almost no analytical method which is applicable to all different matrices due to limitations pertaining to mass analyzers and chromatographic tools. The specifications of the most important interfaces and mass analyzers are discussed. We additionally provide an exemplary application in order to demonstrate the level of complexity which remains intractable up to date. The potential of coupling a high field Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (ICR-FT/MS), the mass analyzer with the largest known mass resolving power, to UHPLC is given with an example of one human pre-treated plasma sample. This experimental example illustrates one way of overcoming the necessity of faster scanning rates in the coupling with UHPLC. The experiment enabled the extraction of thousands of features (analytical signals). A small subset of this compositional space could be mapped into a mass difference network whose topology shows specificity toward putative metabolite classes and retention time. Copyright © 2013 Elsevier B.V. All rights reserved.
Li, Ying-yi; Song, Ye-ying; Liu, Chang-hui; Huang, Xiao-tao; Zheng, Xia; Li, Neng; Xu, Mei-li; Mi, Sui-qing; Wang, Ning-sheng
2012-10-15
A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method operated in the negative electrospray ionization (ESI) switching mode has been developed and validated for the simultaneous determination of esculin and its metabolite esculetin in rat plasma. After addition of internal standards scopoletin, the plasma sample was pretreated by solid-phase extraction (SPE), and separated on a reversed phase C(18) column with a mobile phase of 0.01% formic acid in water (solvent A) and methanol (solvent B) using isocratic elution (A:B=20:80, v/v). The detection of target compounds was done in multiple reaction monitoring (MRM) mode. The MRM detection was operated in the negative ESI mode using the transitions of m/z 339.1 ([M-H](-))→176.7 for esculetin, m/z 176.9 ([M-H](-))→133.0 and m/z 191.0 ([M-H](-))→175.9 for scopoletin. The standard curves, which ranged from 25 to 3200 ng/mL for esculin with the lowest limit of quantification (LLOQ) of 0.25 ng/mL and from 1.25 to 160 ng/mL for esculetin with the LLOQ of 1.25 ng/mL, were fitted to a 1/x weighted quadratic regression model. The method also afforded satisfactory results in terms of the sensitivity, specificity, precision (intra- and inter-day, RSD<8.73%), accuracy, recovery as well as the stability of the analyte under various conditions. The method was successfully applied to study the pharmacokinetics of esculin and its metabolite esculetin in rat plasma after oral administration of esculin at a dose of 100mg/kg. Copyright © 2012 Elsevier B.V. All rights reserved.
Bai, Feng; Minkin, Patton; Fraga, Charles H; O'Shaughnessy, Melinda A; Gururangan, Sri; Stewart, Clinton F
2007-06-15
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV
Stenholm, A; Göransson, U; Bohlin, L
2013-02-01
Selective extraction of plant materials is advantageous for obtaining extracts enriched with desired constituents, thereby reducing the need for subsequent chromatography purification. Such compounds include three cyclooxygenase-2 (COX-2) inhibitory substances in Plantago major L. targeted in this investigation: α-linolenic acid (α-LNA) (18:3 ω-3) and the triterpenic acids ursolic acid and oleanolic acid. To investigate the scope for tuning the selectivity of supercritical fluid extraction (SFE) using bioassay guidance, and Soxhlet extraction with dichloromethane as solvent as a reference technique, to optimise yields of these substances. Extraction parameters were varied to optimise extracts' COX-2/COX-1 inhibitory effect ratios. The crude extracts were purified initially using a solid phase extraction (SPE) clean-up procedure and the target compounds were identified with GC-MS, LC-ESI-MS and LC-ESI-MS² using GC-FID for quantification. α-LNA was preferentially extracted in dynamic mode using unmodified carbon dioxide at 40°C and 172 bar, at a 0.04% (w/w) yield with a COX-2/COX-1 inhibitory effect ratio of 1.5. Ursolic and oleanolic acids were dynamically extracted at 0.25% and 0.06% yields, respectively, with no traces of (α-LNA) and a COX-2/COX-1-inhibitory effect ratio of 1.1 using 10% (v/v) ethanol as polar modifier at 75°C and 483 bar. The Soxhlet extracts had ursolic acid, oleanolic acid and αLNA yields up to 1.36%, 0.34% and 0.15%, respectively, with a COX-2/COX-1 inhibitory effect ratio of 1.2. The target substances can be extracted selectively by bioassay guided optimisation of SFE conditions. Copyright © 2012 John Wiley & Sons, Ltd.
Ortiz, Antonio J.; Cortez, Vieyle; Azzouz, Abdelmonaim
2017-01-01
A new analytical method based on solvent extraction, followed by continuous solid-phase extraction (SPE) clean-up using a polymeric sorbent, was demonstrated to be applicable for the detection of ivermectin in complex biological matrices of dung beetles (hemolymph, excreta or dry tissues) using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI+–MS/MS). Using a signal-to-noise ratio of 3:1, the limit of detection (LOD) in the insect matrices at trace levels was 0.01 ng g–1 and the limit of quantification (LOQ) was 0.1 ng g–1. The proposed method was successfully used to quantitatively determine the levels of ivermectin in the analysis of small samples in in vivo and post mortem samples, demonstrating the usefulness for quantitative analyses that are focused on future pharmacokinetic and bioavailability studies in insects and the establishment of a new protocol to study the impact of ivermectin on non-target arthropods such as dung beetles and other insects that are related with the “dung community”. Because satisfactory precision and accuracy values were obtained in both in vivo matrices, we suggest that the method can be consistently used for quantitative determinations that are focused on future pharmacokinetic and bioavailability studies in insects. Furthermore, this new analytical method was successfully applied to biological samples of dead dung beetles from the field suggesting that the method can be used to establish a new routine analysis of ivermectin residues in insect carcasses that is applied to complement typical mortality tests. PMID:28207908
NASA Astrophysics Data System (ADS)
Chen, Zhidan; Coy, Stephen L.; Pannkuk, Evan L.; Laiakis, Evagelia C.; Hall, Adam B.; Fornace, Albert J.; Vouros, Paul
2016-10-01
Radiation exposure is an important public health issue due to a range of accidental and intentional threats. Prompt and effective large-scale screening and appropriate use of medical countermeasures (MCM) to mitigate radiation injury requires rapid methods for determining the radiation dose. In a number of studies, metabolomics has identified small-molecule biomarkers responding to the radiation dose. Differential mobility spectrometry-mass spectrometry (DMS-MS) has been used for similar compounds for high-throughput small-molecule detection and quantitation. In this study, we show that DMS-MS can detect and quantify two radiation biomarkers, trimethyl-L-lysine (TML) and hypoxanthine. Hypoxanthine is a human and nonhuman primate (NHP) radiation biomarker and metabolic intermediate, whereas TML is a radiation biomarker in humans but not in NHP, which is involved in carnitine synthesis. They have been analyzed by DMS-MS from urine samples after a simple strong cation exchange-solid phase extraction (SCX-SPE). The dramatic suppression of background and chemical noise provided by DMS-MS results in an approximately 10-fold reduction in time, including sample pretreatment time, compared with liquid chromatography-mass spectrometry (LC-MS). DMS-MS quantitation accuracy has been verified by validation testing for each biomarker. Human samples are not yet available, but for hypoxanthine, selected NHP urine samples (pre- and 7-d-post 10 Gy exposure) were analyzed, resulting in a mean change in concentration essentially identical to that obtained by LC-MS (fold-change 2.76 versus 2.59). These results confirm the potential of DMS-MS for field or clinical first-level rapid screening for radiation exposure.
Cornejo, J; Pokrant, E; Araya, D; Briceño, C; Hidalgo, H; Maddaleno, A; Araya-Jordán, C; San Martin, B
2017-04-01
Antibiotics are widely used in poultry production for the treatment of bacterial diseases. However, residues may remain in products and by-products destined for human consumption or animal feeding. The claws of chickens, which are a by-product of the poultry industry, can directly or indirectly enter the food chain as meals destined to feed other productive animals. Thus, it becomes necessary to determine and quantify antimicrobial residues present in this matrix. The objective of the study was to assess the depletion of oxytetracycline (OTC) and its metabolite 4-epi-OTC in broiler chicken's claws. Claws of 32 broilers treated with a therapeutic dosage of 10% OTC during 7 days were analysed. Samples were taken at days 3, 9, 15 and 19 post-treatment. As for the control group, eight broiler chickens were raised under the same conditions. Extraction was carried out through EDTA-McIlvaine buffer, and clean-up employed a SPE C-18 Sep-Pak®. Instrumental analysis was performed through LC-MS/MS. The concentrations of both analytes were determined in claw samples until day 19 post-treatment. Average concentrations were within the LOD (20 μg kg - 1 ) and LOQ (22 µg kg - 1 ) for OTC and 84 μg kg - 1 for 4-epi-OTC. Withdrawal times (WDTs) of 39 days for OTC and 54 days for 4-epi-OTC were established in claws based on 95% confidence. These findings demonstrate that claws can be a source of antimicrobial residue entry into the food chain, since the results showed that OTC and its metabolite can be found in chicken's claws for long periods, even exceeding the average lifespan of a broiler chicken.
Tokumura, Masahiro; Miyake, Yuichi; Wang, Qi; Nakayama, Hayato; Amagai, Takashi; Ogo, Sayaka; Kume, Kazunari; Kobayashi, Takeshi; Takasu, Shinji; Ogawa, Kumiko
2018-04-16
Organophosphorus flame retardants (PFRs) are extensively used as alternatives to banned polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). In this study, we analyzed 14 PFRs by means of four mass-spectrometry-based methods: gas chromatography combined with electron-impact mass spectrometry (GC-EI-MS) or negative-chemical-ionization mass spectrometry (GC-NCI-MS) and liquid chromatography combined with tandem mass spectrometry using electrospray ionization (LC-ESI-MS/MS) or atmospheric pressure chemical ionization (LC-APCI-MS/MS). The limits of quantification (LOQs) for LC-ESI-MS/MS and LC-APCI-MS/MS (0.81-970 pg) were 1-2 orders of magnitude lower than the LOQs for GC-EI-MS and GC-NCI-MS (2.3-3900 pg). LC-APCI-MS/MS showed the lowest LOQs (mean = 41 pg; median = 3.4 pg) for all but two of the PFRs targeted in this study. For LC-APCI-MS/MS, the lowest LOQ was observed for tributyl phosphate (TBP) (0.81 pg), and the highest was observed for tris(butoxyethyl) phosphate (TBOEP) (36 pg). The results of this study indicate that LC-APCI-MS/MS is the optimum analytical method for the target PFRs, at least in terms of LOQ.
Fluorous Parallel Synthesis of A Hydantoin/Thiohydantoin Library
Lu, Yimin; Zhang, Wei
2007-01-01
Fluorous tagging strategy is applied to solution-phase parallel synthesis of a library containing hydantoin and thiohydantoin analogs. Two perfluoroalkyl (Rf)-tagged α-amino esters each react with 6 aromatic aldehydes under reductive amination conditions. Twelve amino esters then each react with 10 isocyanates and isothiocyanates in parallel. The resulting 120 ureas and thioureas undergo spontaneous cyclization to form the corresponding hydantoins and thiohydantoins. The intermediate and final product purifications are performed with solid-phase extraction (SPE) over FluoroFlash™ cartridges, no chromatography is required. Using standard instruments and straightforward SPE technique, one chemist accomplished the 120-member library synthesis in less than 5 working days, including starting material synthesis and product analysis. PMID:15789556
Pindado Jiménez, Oscar; Pérez Pastor, Rosa Ma; Escolano Segovia, Olga; del Reino Querencia, Susana
2015-01-01
This work proposes an analytical procedure for measuring aliphatic and aromatic hydrocarbons fractions present in groundwater. In this method, hydrocarbons are solid phase extracted (SPE) twice from the groundwater and the resulting fractions are analyzed by gas chromatography with flame ionization detection. The first SPE disposes the hydrocarbons present in groundwater in organic solvents and the second SPE divides them into aliphatic and aromatic hydrocarbons. The validation study is carried out and its uncertainties are discussed. Identifying the main sources of uncertainty is evaluated through applying the bottom-up approach. Limits of detection for hydrocarbons ranges are below 5 µg L(-1), precision is not above of 30%, and acceptable recoveries are reached for aliphatic and aromatic fractions studied. The uncertainty due to volume of the sample, factor of calibration and recovery are the highest contributions. The expanded uncertainty range from 13% to 26% for the aliphatic hydrocarbons ranges and from 14% to 23% for the aromatic hydrocarbons ranges. As application, the proposed method is satisfactorily applied to a set of groundwater samples collected in a polluted area where there is evidence to present a high degree of hydrocarbons. The results have shown the range of aliphatic hydrocarbons >C21-C35 is the most abundant, with values ranging from 215 µg L(-1) to 354 µg L(-1), which it is associated to a contamination due to diesel. Copyright © 2014 Elsevier B.V. All rights reserved.
Guillarme, Davy; Desfontaine, Vincent; Heinisch, Sabine; Veuthey, Jean-Luc
2018-04-15
Mass spectrometry (MS) is considered today as one of the most popular detection methods, due to its high selectivity and sensitivity. In particular, this detector has become the gold standard for the analysis of complex mixtures such as biological samples. The first successful SFC-MS hyphenation was reported in the 80's, and since then, several ionization sources, mass analyzers and interfacing technologies have been combined. Due to the specific physicochemical properties and compressibility of the SFC mobile phase, directing the column effluent into the ionization source is more challenging than in LC. Therefore, some specific interfaces have to be employed in SFC-MS, to i) avoid (or at least limit) analytes precipitation due to CO 2 decompression, when the SFC mobile phase is not anymore under backpressure control, ii) achieve adequate ionization yield, even with a low proportion of MeOH in the mobile phase and iii) preserve the chromatographic integrity (i.e. maintaining retention, selectivity, and efficiency). The goal of this review is to describe the various SFC-MS interfaces and highlight the most favorable ones in terms of reliability, flexibility, sensitivity and user-friendliness. Copyright © 2018 Elsevier B.V. All rights reserved.
Månsson, Maria; Phipps, Richard K; Gram, Lone; Munro, Murray H G; Larsen, Thomas O; Nielsen, Kristian F
2010-06-25
Microbial natural products (NP) cover a high chemical diversity, and in consequence extracts from microorganisms are often complex to analyze and purify. A distribution analysis of calculated pK(a) values from the 34390 records in Antibase2008 revealed that within pH 2-11, 44% of all included compounds had an acidic functionality, 17% a basic functionality, and 9% both. This showed a great potential for using ion-exchange chromatography as an integral part of the separation procedure, orthogonal to the classic reversed-phase strategy. Thus, we investigated the use of an "explorative solid-phase extraction" (E-SPE) protocol using SAX, Oasis MAX, SCX, and LH-20 columns for targeted exploitation of chemical functionalities. E-SPE provides a minimum of fractions (15) for chemical and biological analyses and implicates development into a preparative scale methodology. Overall, this allows fast extract prioritization, easier dereplication, mapping of biological activities, and formulation of a purification strategy.
Dunn, Philip J H; Honch, Noah V; Evershed, Richard P
2011-10-30
Results are presented of a comparison of the amino acid (AA) δ(13)C values obtained by gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) and liquid chromatography-isotope ratio mass spectrometry (LC/IRMS). Although the primary focus was the compound-specific stable carbon isotope analysis of bone collagen AAs, because of its growing application for palaeodietary and palaeoecological reconstruction, the results are relevant to any field where AA δ(13)C values are required. We compare LC/IRMS with the most up-to-date GC/C/IRMS method using N-acetyl methyl ester (NACME) AA derivatives. This comparison involves the analysis of standard AAs and hydrolysates of archaeological human bone collagen, which have been previously investigated as N-trifluoroacetyl isopropyl esters (TFA/IP). It was observed that, although GC/C/IRMS analyses required less sample, LC/IRMS permitted the analysis of a wider range of AAs, particularly those not amenable to GC analysis (e.g. arginine). Accordingly, reconstructed bulk δ(13)C values based on LC/IRMS-derived δ(13)C values were closer to the EA/IRMS-derived δ(13)C values than those based on GC/C/IRMS values. The analytical errors for LC/IRMS AA δ(13)C values were lower than GC/C/IRMS determinations. Inconsistencies in the δ(13)C values of the TFA/IP derivatives compared with the NACME- and LC/IRMS-derived δ(13)C values suggest inherent problems with the use of TFA/IP derivatives, resulting from: (i) inefficient sample combustion, and/or (ii) differences in the intra-molecular distribution of δ(13)C values between AAs, which are manifested by incomplete combustion. Close similarities between the NACME AA δ(13)C values and the LC/IRMS-derived δ(13)C values suggest that the TFA/IP derivatives should be abandoned for the natural abundance determinations of AA δ(13)C values. Copyright © 2011 John Wiley & Sons, Ltd.
Orrego-Lagarón, Naiara; Vallverdú-Queralt, Anna; Martínez-Huélamo, Miriam; Lamuela-Raventos, Rosa M; Escribano-Ferrer, Elvira
2016-02-20
Several biological activities (antioxidant, anti-inflammatory, anticarcinogenic) are attributed to naringenin (NAR)-a predominant flavonoid of citrus fruit and tomato-despite its low bioavailability after ingestion. NAR undergoes extensive metabolism when crossing the gastrointestinal tract, resulting in enteric, hepatic and microbial metabolites, some of them with recognized beneficial effects on human health. This study sought to provide new insights into the metabolism of NAR in regions of the gastrointestinal tract where it has been less studied: the stomach and colon. With this purpose, liquid chromatography coupled with an electrospray ionization hybrid linear ion trap quadrupole Orbitrap mass spectrometry technique (LC-ESI-LTQ-Orbitrap-MS) was used for an accurate identification of NAR metabolites, and liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) on a triple quadrupole was used for their identification and quantification. The combination of both analytical techniques provided a broader metabolic profile of NAR. As far as we know, this is the first in-depth metabolic profiling study of NAR in the stomach of mice. Three of the metabolites determined using the LC-LTQ-Orbitrap could not be identified by LC-ESI-MS/MS in stomach perfusion samples: apigenin, 3-(4-hydroxyphenyl) propionic acid and phloroglucinol. The number of colonic metabolites determined using the LTQ-Orbitrap-MS was more than twice the number identified by LC-ESI-MS/MS. Copyright © 2015 Elsevier B.V. All rights reserved.
Bishop, David P; Blanes, Lucas; Wilson, Alexander B; Wilbanks, Thor; Killeen, Kevin; Grimm, Rudolf; Wenzel, Ross; Major, Derek; Macka, Mirek; Clarke, David; Schmid, Robin; Cole, Nerida; Doble, Philip A
2017-05-12
The Agilent Chip Cube Interface is a microfluidic chip-based technology originally designed for nanospray molecular mass spectrometry in which the sample enrichment, nano-column, tubing, connectors and spray tip were integrated into a single biocompatible chip. Here we describe the hyphenation of the Chip Cube Interface to ICP-MS via modification of the standard HPLC chip design and a new total consumption nebuliser suitable for flow rates as low as 300nLmin -1 . The potential of the instrument to eliminate common nanoLC - ICP-MS shortcomings such as leaks, blockages and band-broadening was demonstrated via analysis of cyanocobalamin in equine plasma. The method was linear over three orders of magnitude with an r 2 of 0.9999, the peak area repeatability was 1.9% (n=7), and the detection limit was 14ngmL -1 . This novel configuration of the Chip Cube Interface coupled to ICP-MS is a suitable platform for the analysis of biomolecules associated with trace metals and speciation applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhou, Jian-Liang; An, Jing-Jing; Li, Ping; Li, Hui-Jun; Jiang, Yan; Cheng, Jie-Fei
2009-03-20
We present herein a novel bioseparation/chemical analysis strategy for protein-ligand screening and affinity ranking in compound mixtures, designed to increase screening rates and improve sensitivity and ruggedness in performance. The strategy is carried out by combining on-line two-dimensional turbulent flow chromatography (2D-TFC) with liquid chromatography-mass spectrometry (LC-MS), and accomplished through the following steps: (1) a reversed-phase TFC stage to separate the protein/ligand complex from the unbound free molecules, (2) an on-line dissociation process to release the bound ligands from the complexes, and (3) a second mixed-mode cation-exchange/reversed-phase TFC stage to trap the bound ligands and to remove the proteins and salts, followed by LC-MS analysis for identification and determination of the binding affinities. The technique can implement an ultra-fast isolation of protein/ligand complex with the retention time of a complex peak in about 5s, and on-line prepare the "clean" sample to be directly compatible with the LC-MS analysis. The improvement in performance of this 2D-TFC/LC-MS approach over the conventional approach has been demonstrated by determining affinity-selected ligands of the target proteins acetylcholinesterase and butyrylcholinesterase from a small library with known binding affinities and a steroidal alkaloid library composed of structurally similar compounds. Our results show that 2D-TFC/LC-MS is a generic and efficient tool for high-throughput screening of ligands with low-to-high binding affinities, and structure-activity relationship evaluation.
Gunn, Josh; Kriger, Scott; Terrell, Andrea R
2010-01-01
The simultaneous determination and quantification of cocaine and its major metabolite, benzoylecgonine, in meconium using UPLC-MS/MS is described. Ultra-performance liquid chromatography (UPLC) is an emerging analytical technique which draws upon the principles of chromatography to run separations at higher flow rates for increased speed, while simultaneously achieving superior resolution and sensitivity. Extraction of cocaine and benzoylecgonine from the homogenized meconium matrix was achieved with a preliminary protein precipitation or protein 'crash' employing cold acetonitrile, followed by a mixed mode solid phase extraction (SPE). Following elution from the SPE cartridge, eluents were dried down under nitrogen, reconstituted in 200 microL of DI water:acetonitrile (ACN) (75:25), and injected onto the UPLC/MS/MS for analysis. The increased speed and separation efficiency afforded by UPLC, allowed for the separation and subsequent quantification of both analytes in less than 2 min. Analytes were quantified using multiple reaction monitoring (MRM) and six-point calibration curves constructed in negative blood. Limits of detection for both analytes were 3 ng/g and the lower limit of quantitation (LLOQ) was 30 ng/g.
Chatterjee, Niladri S; Utture, Sagar; Banerjee, Kaushik; Ahammed Shabeer, T P; Kamble, Narayan; Mathew, Suseela; Ashok Kumar, K
2016-04-01
This paper reports a selective and sensitive method for multiresidue determination of 119 chemical residues including pesticides and polyaromatic hydrocarbons (PAH) in high fatty fish matrix. The novel sample preparation method involved extraction of the target analytes from homogenized fish meat (5 g) in acetonitrile (15 mL, 1% acetic acid) after three-phase partitioning with hexane (2 mL) and the remaining aqueous layer. An aliquot (1.5 mL) of the acetonitrile layer was aspirated and subjected to two-stage dispersive solid phase extraction (dSPE) cleanup and the residues were finally estimated by gas chromatography mass spectrometry with selected reaction monitoring (GC-MS/MS). The co-eluted matrix components were identified on the basis of their accurate mass by GC with quadrupole time of flight MS. Addition of hexane during extraction and optimized dSPE cleanup significantly minimized the matrix effects. Recoveries at 10, 25 and 50 μg/kg were within 60-120% with associated precision, RSD<11%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Li, Jing; Zhang, Yuting; Cheng, Youpu; Yuan, Shankui; Liu, Lei; Shao, Hui; Li, Hui; Li, Na; Zhao, Pengyue; Guo, Yongze
2016-03-20
A novel and sensitive ultra-high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous enantioselective determination of flufiprole and its hydrolysis metabolite in paddy field ecosystem. The separation and determination were performed using reversed-phase chromatography on a novel cellulose chiral stationary phase, a Lux Cellulose-4 (150 mm × 2.0 mm) column, under isocratic conditions at 0.25 mL/min flow rate. The effects of other four different polysaccharide-based chiral stationary phases (CSPs) on the separation and simultaneous enantioseparation of the two target compounds were also evaluated. The elution orders of the eluting enantiomers were identified by an optical rotation detector. Modified QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the enrichment and cleanup of paddy water, rice straw, brown rice and paddy soil samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under the optimal conditions, the mean recoveries for all enantiomers from the above four sample matrix were ranged from 83.6% to 107%, with relative standard deviations (RSD) in the range of 1.0-5.8%. Coefficients of determination R(2)≥0.998 were achieved for each enantiomer in paddy water, rice straw, brown rice and paddy soil matrix calibration curves within the range of 5-500 μg/kg. The limits of quantification (LOQ) for all stereoisomers in the above four matrices were all below 2.0 μg/kg. The methodology was successfully applied for simultaneously enantioselective analysis of flufiprole enantiomers and their chiral metabolite in the real samples, indicating its efficacy in investigating the environmental stereochemistry of flufiprole in paddy field ecosystem. Copyright © 2016 Elsevier B.V. All rights reserved.
Kiljanek, Tomasz; Niewiadowska, Alicja; Semeniuk, Stanisław; Gaweł, Marta; Borzęcka, Milena; Posyniak, Andrzej
2016-02-26
A method for the determination of 200 pesticides and pesticide metabolites in honeybee samples has been developed and validated. Almost 98% of compounds included in this method are approved to use within European Union, as active substances of plant protection products or veterinary medicinal products used by beekeepers to control mites Varroa destructor in hives. Many significant metabolites, like metabolites of imidacloprid, thiacloprid, fipronil, methiocarb and amitraz, are also possible to detect. The sample preparation was based on the buffered QuEChERS method. Samples of bees were extracted with acetonitrile containing 1% acetic acid and then subjected to clean-up by dispersive solid phase extraction (dSPE) using a new Z-Sep+ sorbent and PSA. The majority of pesticides, including neonicotionoids and their metabolites, were analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS) but some of pesticides, especially pyrethroid insecticides, were analyzed by gas chromatography tandem mass spectrometry (GC-MS/MS). The procedure was validated according to the Guidance document SANCO/12571/2013 at four concentration levels: 1, 5, 10 and 100 ng/g bees and verified in the international proficiency test. The analysis of bee samples spiked at the limit of quantification (LOQ) showed about 98% mean recovery value (trueness) and 97% of analytes showed recovery in the required range of 70-120% and RSDr (precision) below 20%. Linearity and matrix effects were also established. The LOQs of pesticides were in the range of 1-100 ng/g. The developed method allows determination of insecticides at concentrations of 10 ng/g or less, except abamectin and tebufenozide. LOQ values are lower than the median lethal doses LD50 for bees. The method was used to investigate more than 70 honeybee poisoning incidents. Data about detected pesticides and their metabolites are included. Copyright © 2016 Elsevier B.V. All rights reserved.
Li, Yuanbo; Dong, Fengshou; Liu, Xingang; Xu, Jun; Chen, Xiu; Han, Yongtao; Liang, Xuyang; Zheng, Yongquan
2013-04-15
A novel and sensitive chiral liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous measuring individual enantiomers of 9 pesticides including herbicides, insecticides, and fungicides in soil and water. The separation and determination were performed using reversed-phase chromatography on an amylose chiral stationary phase, a Chiralpak AD-RH column, under gradient elution using a mixture of ACN-2mM ammonium acetate in water as the mobile phase at 0.45 mL/min flow rate. The effects of three cellulose-based columns and three amylose-based columns on the separation were also investigated. The QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the extraction and clean-up of the soil and water samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were undertaken. Under optimal conditions, the mean recoveries for all enantiomers from the soil and water samples were ranged from 77.8% to 106.2% with the relative standard deviations (RSD) less than 14.2%. Good linearity (at least R(2) ≥ 0.9986) was obtained for all studied analytes in the soil and water matrix calibration curves over the range from 2.0 to 125 μg/L. The limits of detection (LOD) for all enantiomers in the soil and water were less than 1.8 μg/kg or μg/L, whereas the limit of quantification (LOQ) did not exceed 5.0 μg/kg or μg/L. The results of the method validation confirm that this proposed method is convenient and reliable for the enantioselective determination of the enantiomers of 9 chiral pesticides in soil and water. Copyright © 2013 Elsevier B.V. All rights reserved.
Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Lee, Young-Jun; Na, Tae-Woong; Park, Joon-Seong; Shin, Ho-Chul; Shim, Jae-Han
2017-01-01
A high-performance liquid chromatography-fluorescence detection method was developed for the simultaneous determination of thiodicarb and its degradation product methomyl in animal-derived food products, including chicken muscle, beef, pork, table eggs, and milk. Thiodicarb is known to degrade during analysis; therefore, a thorough investigation was carried out, revealing that thiodicarb degrades to methomyl immediately after spiking into a matrix of animal-derived food products. Consequently, thiodicarb was determined as the sum of the parent compound and methomyl. Samples were extracted with acetonitrile and sodium salts, and purified using solid-phase extraction (SPE). The limits of detection (LODs) and quantification (LOQs) were 0.0013 and 0.004mg/kg, respectively, for both analytes in various matrices. Seven-point external calibration curves were obtained, and they showed excellent linearity with determination coefficients (R 2 )≥0.999 for all tested matrices. The method was validated at three fortification levels (LOQ, LOQ×2, and LOQ×10) in triplicate with average recoveries ranging from 84.24 to 112.8% (for methomyl) and relative standard deviations (RSDs)≤6.5% in all matrices. The converted recoveries of thiodicarb in various matrices ranged from 74.80 to 107.80% with RSDs≤4.5%. The identities of both compounds in standard solutions and for recovery were confirmed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The developed method was further validated by accurate reproduction at another laboratory. Finally, the method was applied to market samples collected from different areas (and, in the case of milk, different brands), and none of the samples tested positive for thiodicarb or methomyl. In conclusion, the developed method can be successfully applied for a single-run analysis of thiodicarb and methomyl in livestock products. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huo, Hanyu; Sun, Jiyang; chen, Cheng; Meng, Xianglu; He, Minghui; Zhao, Ning; Guo, Xiangxin
2018-04-01
Flexible interfaces between Si anodes and composite electrolytes consisting of poly(propylene carbonates) (PPCs) and garnets have been fabricated. The solid polymer electrolytes (SPEs) of PPC/garnet/LiTFSI show the conductivity of 4.2 × 10-4 S cm-1 at room temperature. Their combination with the Si layer anodes allows great alleviation of internal stress resulting from the large volume variation during lithiation and delithiation process of Si anodes. As a result, the Si/SPE/Li cells exhibit 2520 mAh g-1, 2260 mAh g-1, 1902 mAh g-1, 1342 mAh g-1 at 0.1 C, 0.2 C, 0.5 C, and 1 C, respectively. Furthermore, with such compatible and stable interfaces of Si/SPE and the LiFePO4 cathodes in solid-state batteries, the specific capacity of 2296 mAh g-1 in terms of Si is obtained, which remains 82.6% after 100 cycles at room temperature and 0.1 C. The results here indicate that constructing of flexible interfaces between Si anodes and SPEs is a promising strategy to develop high performance solid-state batteries.
Santos, Mônica Cardoso; Navickiene, Sandro; Gaujac, Alain
2017-05-01
Ayahuasca is a potent hallucinogenic beverage prepared from Banisteriopsis caapi in combination with other psychoactive plants. N,N-dimethyltryptamine, tryptamine, harmine, harmaline, harmalol, and tetrahydroharmine were quantified in ayahuasca samples using a simple and low-cost method based on SPE and LC with UV diode-array detection. The experimental variables that affect the SPE method, such as type of solid phase and nature of solvent, were optimized. The method showed good linearity (r > 0.9902) and repeatability (RSD < 0.8%) for alkaloid compounds, with an LOD of 0.12 mg/L. The proposed method was used to analyze 20 samples from an ayahuasca cooking process from a religious group located in the municipality of Fortaleza, state of Ceará, Brazil. The results showed that concentrations of the target compounds ranged from 0.3 to 36.7 g/L for these samples.
Tang, Caiming; Tan, Jianhua; Fan, Ruifang; Zhao, Bo; Tang, Caixing; Ou, Weihui; Jin, Jiabin; Peng, Xianzhi
2016-08-26
Metabolite identification is crucial for revealing metabolic pathways and comprehensive potential toxicities of polycyclic aromatic hydrocarbons (PAHs) in human body. In this work, a quasi-targeted analysis strategy was proposed for metabolite identification of monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in human urine using liquid chromatography triple quadruple mass spectrometry (LC-QqQ-MS/MS) combined with liquid chromatography high resolution mass spectrometry (LC-HRMS). Potential metabolites of OH-PAHs were preliminarily screened out by LC-QqQ-MS/MS in association with filtering in a self-constructed information list of possible metabolites, followed by further identification and confirmation with LC-HRMS. The developed method can provide more reliable and systematic results compared with traditional untargeted analysis using LC-HRMS. In addition, data processing for LC-HRMS analysis were greatly simplified. This quasi-targeted analysis method was successfully applied to identifying phase I and phase II metabolites of OH-PAHs in human urine. Five metabolites of hydroxynaphthalene, seven of hydroxyfluorene, four of hydroxyphenanthrene, and three of hydroxypyrene were tentatively identified. Metabolic pathways of PAHs in human body were putatively revealed based on the identified metabolites. The experimental results will be valuable for investigating the metabolic processes of PAHs in human body, and the quasi-targeted analysis strategy can be expanded to the metabolite identification and profiling of other compounds in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.
Vialaret, Jérôme; Picas, Alexia; Delaby, Constance; Bros, Pauline; Lehmann, Sylvain; Hirtz, Christophe
2018-06-01
Hepcidin-25 peptide is a biomarker which is known to have considerable clinical potential for diagnosing iron-related diseases. Developing analytical methods for the absolute quantification of hepcidin is still a real challenge, however, due to the sensitivity, specificity and reproducibility issues involved. In this study, we compare and discuss two MS-based assays for quantifying hepcidin, which differ only in terms of the type of liquid chromatography (nano LC/MS versus standard LC/MS) involved. The same sample preparation, the same internal standards and the same MS analyzer were used with both approaches. In the field of proteomics, nano LC chromatography is generally known to be more sensitive and less robust than standard LC methods. In this study, we established that the performances of the standard LC method are equivalent to those of our previously developed nano LC method. Although the analytical performances were very similar in both cases. The standard-flow platform therefore provides the more suitable alternative for accurately determining hepcidin in clinical settings. Copyright © 2018 Elsevier B.V. All rights reserved.
Sorger, Dietlind; Becker, Georg A; Patt, Marianne; Schildan, Andreas; Grossmann, Udo; Schliebs, Reinhard; Seese, Anita; Kendziorra, Kai; Kluge, Magnus; Brust, Peter; Mukhin, Alexey G; Sabri, Osama
2007-04-01
2-[(18)F]fluoro-A-85380 (2-[(18)F]FA) is a new radioligand for noninvasive imaging of alpha4beta2* nicotinic acetylcholine receptors (nAChRs) by positron emission tomography (PET) in human brain. In most cases, quantification of 2-[(18)F]FA receptor binding involves measurement of free nonmetabolized radioligand concentration in blood. This requires an efficient and reliable method to separate radioactive metabolites from the parent compound. In the present study, three analytical methods, thin layer chromatography (TLC), high-performance liquid chromatography (HPLC) and solid phase extraction (SPE) have been tested. Reversed-phase TLC of deproteinized aqueous samples of plasma provides good estimates of 2-[(18)F]FA and its metabolites. However, because of the decreased radioactivity in plasma samples, this method can be used in humans over the first 2 h after radioligand injection only. Reliable quantification of the parent radioligand and its main metabolites was obtained using reversed-phase HPLC, followed by counting of eluted fractions in a well gamma counter. Three main and five minor metabolites of 2-[(18)F]FA were detected in human blood using this method. On average, the unchanged 2-[(18)F]FA fraction in plasma of healthy volunteers measured at 14, 60, 120, 240 and 420 min after radioligand injection was 87.3+/-2.2%, 74.4+/-3%, 68.8+/-5%, 62.3+/-8% and 61.0+/-8%, respectively. In patients with neurodegenerative disorders, the values corresponding to the three last time points were significantly lower. The fraction of nonmetabolized 2-[(18)F]FA in plasma determined using SPE did not differ significantly from that obtained by HPLC (+gamma counting) (n=73, r=.95). Since SPE is less time-consuming than HPLC and provides comparable results, we conclude that SPE appears to be the most suitable method for measurement of 2-[(18)F]FA parent fraction during PET investigations.
Potter, Thomas L; Mohamed, Mahmoud A; Ali, Hannah
2007-01-24
Monitoring of water resources for pesticide residues is often needed to ensure that pesticide use does not adversely impact the quality of public water supplies or the environment. In many rural areas and throughout much of the developing world, monitoring is often constrained by lack of testing facilities; thus, collection of samples and shipment to centralized laboratories for analysis is required. The portability, ease of use, and potential to enhance analyte stability make solid-phase extraction (SPE) an attractive technique for handling water samples prior to their shipment. We describe performance of an SPE method targeting a structurally diverse mixture of 25 current-use pesticides and two common degradates in samples of raw and filtered drinking water collected in Greater Cairo, Egypt. SPE was completed in a field laboratory in Egypt, and cartridges were shipped to the United States for elution and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry analysis. Quantitative and reproducible recovery of 23 of 27 compounds (average = 96%; percent relative standard deviation = 21%) from matrix spikes (1 microg L-1 per component) prepared in the field and from deionized water fortified similarly in the analytical laboratory was obtained. Concurrent analysis of unspiked samples identified four parent compounds and one degradate in drinking water samples. No significant differences were observed between raw and filtered samples. Residue levels in all cases were below drinking water and "harm to aquatic-life" thresholds, indicating that human and ecological risks of pesticide contamination were relatively small; however, the study was limited in scale and scope. Further monitoring is needed to define spatial and temporal variation in residue concentrations. The study has demonstrated the feasibility of performing studies of this type using SPE to extract and preserve samples in the field. The approach should be broadly applicable in many settings.
Rocío-Bautista, Priscilla; Pino, Verónica; Ayala, Juan H; Pasán, Jorge; Ruiz-Pérez, Catalina; Afonso, Ana M
2016-03-04
A hybrid material composed by the metal-organic framework (MOF) HKUST-1 and Fe3O4 magnetic nanoparticles (MNPs) has been synthetized in a quite simple manner, characterized, and used in a magnetic-assisted dispersive micro-solid-phase extraction (M-d-μSPE) method in combination with ultra-high-performance liquid chromatography (UHPLC) and fluorescence detection (FD). The application was devoted to the determination of 8 heavy polycyclic aromatic hydrocarbons (PAHs) in different aqueous samples, specifically tap water, wastewaters, and fruit tea infusion samples. The overall M-d-μSPE-UHPLC-FD method was optimized and validated. The method is characterized by: its simplicity in both the preparation of the hybrid material (simple mixing) and the magnetic-assisted approach (∼10min extraction time), the use of low sorbent amounts (20mg of HKUST-1 and 5mg of Fe3O4 MNPs), and the low organic solvent consumption in the overall M-d-μSPE-UHPLC-FD method (1.5mL of acetonitrile in the M-d-μSPE method and 2.8mL of acetonitrile in the UHPLC-FD run). The resulting method has high sensitivity, with LODs down to 0.8ngL(-1); adequate intermediate precision, with relative standard deviation values (RSD) always lower than 6.3% (being the range 5.9-9.0% in tap water for a spiked level of 45ngL(-1), 6.1-14% in wastewaters for a spiked level of 45ngL(-1), and 7.2-17% in fruit tea infusion samples for a spiked level of 45ngL(-1)); and adequate relative recoveries, with average values of 82% in tap water, and 94% and 75% in wastewater and fruit tea infusion samples, respectively, if using the proper matrix-matched calibration. Copyright © 2016 Elsevier B.V. All rights reserved.
Pantò, Sebastiano; Sciarrone, Danilo; Maimone, Mariarosa; Ragonese, Carla; Giofrè, Salvatore; Donato, Paola; Farnetti, Sara; Mondello, Luigi
2015-10-23
The present research deals with the multi-collection of the most important sesquiterpene alcohols belonging to sandalwood essential oil, as reported by the international regulations: (Z)-α-santalol, (Z)-α-trans bergamotol, (Z)-β-santalol, epi-(Z)-β-santalol, α-bisabolol, (Z)-lanceol, and (Z)-nuciferol. A versatile multidimensional preparative system, based on the hyphenation of liquid and gas chromatography techniques, was operated in the LC-GC-GC-prep or GC-GC-GC-prep configuration, depending on the concentration to be collected from the sample, without any hardware or software modification. The system was equipped with a silica LC column in combination with polyethylene glycol-poly(5% diphenyl/95% dimethylsiloxane)-medium polarity ionic liquid or β-cyclodextrin based GC stationary phases. The GC-GC-GC-prep configuration was exploited for the collection of four components, by using a conventional split/splitless injector, while the LC-GC-GC-prep approach was applied for three low abundant components (<5%), in order to increase the quantity collected within a single run, by the LC injection of a high sample amount. All target compounds, whose determination is hampered by the unavailability of commercial standards, were collected at milligram levels and with a high degree of purity (>87%). Copyright © 2015 Elsevier B.V. All rights reserved.
Hansen, Martin; Poulsen, Rikke; Luong, Xuan; Sedlak, David L; Hayes, Tyrone
2014-11-01
This paper presents the development, optimization, and validation of a LC-MS/MS methodology to determine the concentration of the antifungal drug and fungicide tebuconazole in a controlled exposure study of African clawed frogs (Xenopus laevis). The method is validated on animal tank water and on tissue from exposed and non-exposed adult X. laevis. Using solid-phase extraction (SPE), the analytical method allows for quantification of tebuconazole at concentrations as low as 3.89 pg mL(-1) in 10 mL water samples. Using bead-beating-assisted matrix solid-phase dispersion (MSPD), it was possible to quantify tebuconazole down to 0.63 pg mg(-1) wet weight liver using 150 mg tissue. The deuterated analogue of tebuconazole was used as internal standard, and ensured method accuracy in the range 80.6-99.7% for water and 68.1-109% for tissue samples. The developed method was successfully applied in a 4-week X. laevis repeated-exposure study, revealing high levels of tebuconazole residues in adipose and liver tissue, and with experimental bioconcentration factors up to 18,244 L kg(-1).
Grassetti, Andrew V; Hards, Rufus; Gerber, Scott A
2017-07-01
Technological advances in liquid chromatography and tandem mass spectrometry (LC-MS/MS) have enabled comprehensive analyses of proteins and their post-translational modifications from cell culture and tissue samples. However, sample complexity necessitates offline prefractionation via a chromatographic method that is orthogonal to online reversed-phase high-performance liquid chromatography (RP-HPLC). This additional fractionation step improves target identification rates by reducing the complexity of the sample as it is introduced to the instrument. A commonly employed offline prefractionation method is high pH reversed-phase (Hi-pH RP) chromatography. Though highly orthogonal to online RP-HPLC, Hi-pH RP relies on buffers that interfere with electrospray ionization. Thus, samples that are prefractionated using Hi-pH RP are typically desalted prior to LC-MS/MS. In the present work, we evaluate an alternative offline prefractionation method, pentafluorophenyl (PFP)-based reversed-phase chromatography. Importantly, PFP prefractionation results in samples that are dried prior to analysis by LC-MS/MS. This reduction in sample handling relative to Hi-pH RP results in time savings and could facilitate higher target identification rates. Here, we have compared the performances of PFP and Hi-pH RP in offline prefractionation of peptides and phosphopeptides that have been isolated from human cervical carcinoma (HeLa) cells. Given the prevalence of isobaric mass tags for peptide quantification, we evaluated PFP chromatography of peptides labeled with tandem mass tags. Our results suggest that PFP is a viable alternative to Hi-pH RP for both peptide and phosphopeptide offline prefractionation.
Yan, Xia; Wang, Li-Juan; Wu, Zhen; Wu, Yun-Long; Liu, Xiu-Xiu; Chang, Fang-Rong; Fang, Mei-Juan; Qiu, Ying-Kun
2016-10-15
Microbial metabolites represent an important source of bioactive natural products, but always exhibit diverse of chemical structures or complicated chemical composition with low active ingredients content. Traditional separation methods rely mainly on off-line combination of open-column chromatography and preparative high performance liquid chromatography (HPLC). However, the multi-step and prolonged separation procedure might lead to exposure to oxygen and structural transformation of metabolites. In the present work, a new two-dimensional separation workflow for fast isolation and analysis of microbial metabolites from Chaetomium globosum SNSHI-5, a cytotoxic fungus derived from extreme environment. The advantage of this analytical comprehensive two-dimensional liquid chromatography (2D-LC) lies on its ability to analyze the composition of the metabolites, and to optimize the separation conditions for the preparative 2D-LC. Furthermore, gram scale preparative 2D-LC separation of the crude fungus extract could be performed on a medium-pressure liquid chromatograph×preparative high-performance liquid chromatography system, under the optimized condition. Interestingly, 12 cytochalasan derivatives, including two new compounds named cytoglobosin Ab (3) and isochaetoglobosin Db (8), were successfully obtained with high purity in a short period of time. The structures of the isolated metabolites were comprehensively characterized by HR ESI-MS and NMR. To be highlighted, this is the first report on the combination of analytical and preparative 2D-LC for the separation of microbial metabolites. The new workflow exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio
2013-12-15
The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in the low nanogram per liter range. © 2013 Elsevier B.V. All rights reserved.
Jezová, Vera; Skládal, Jan; Eisner, Ales; Bajerová, Petra; Ventura, Karel
2007-12-07
This paper deals with comparison of efficiency of extraction techniques (solid-phase extraction, SPE and solid-phase microextraction, SPME) used for extraction of nitrate esters (ethyleneglycoldinitrate, EGDN and nitroglycerin, NG), representing the first step of the method of quantitative determination of trace concentrations of nitrate esters in water samples. EGDN and NG are subsequently determined by means of high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of SPE and SPME conditions was carried out using model water samples. Seven SPE cartridges were tested and the conditions were optimized (type of sorbent, type and volume of solvent to be used as eluent). For both nitrate esters the limit of detection (LOD) and the limit of quantification (LOQ) obtained using SPE/HPLC-UV were 0.23 microg mL(-1) and 0.70 microg mL(-1), respectively. Optimization of SPME conditions: type of SPME fibre (four fibres were tested), type and time of sorption/desorption, temperature of sorption. PDMS/DVB (polydimethylsiloxane/divinylbenzene) fibre coating proved to be suitable for extraction of EGDN and NG. For this fibre the LOD and the LOQ for both nitrate esters were 0.16 microg mL(-1) and 0.50 microg mL(-1), respectively. Optimized methods SPE/HPLC-UV and SPME/HPLC-UV were then used for quantitative determination of nitrate esters content in real water samples from the production of EGDN and NG.
Xu, Li; Lee, Hian Kee
2008-05-30
A single-step extraction-cleanup procedure involving microwave-assisted extraction (MAE) and micro-solid-phase extraction (micro-SPE) has been developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) from soil samples. Micro-SPE is a relatively new extraction procedure that makes use of a sorbent enclosed within a sealed polypropylene membrane envelope. In the present work, for the first time, graphite fiber was used as a sorbent material for extraction. MAE-micro-SPE was used to cleanup sediment samples and to extract and preconcentrate five PAHs in sediment samples prepared as slurries with addition of water. The best extraction conditions comprised of microwave heating at 50 degrees C for a duration of 20 min, and an elution (desorption) time of 5 min using acetonitrile with sonication. Using gas chromatography (GC)-flame ionization detection (FID), the limits of detection (LODs) of the PAHs ranged between 2.2 and 3.6 ng/g. With GC-mass spectrometry (MS), LODs were between 0.0017 and 0.0057 ng/g. The linear ranges were between 0.1 and 50 or 100 microg/g for GC-FID analysis, and 1 and 500 or 1000 ng/g for GC-MS analysis. Granular activated carbon was also used for the micro-SPE device but was found to be not as efficient in the PAH extraction. The MAE-micro-SPE method was successfully used for the extraction of PAHs in river and marine sediments, demonstrating its applicability to real environmental solid matrixes.
He, Jianyu; Han, Shengli; Yang, Fangfang; Zhou, Nan; Wang, Sicen
2013-01-01
Uncaria rhynchophylla is a traditional Chinese medicinal herb used to treat hypertension and convulsive disorders such as epilepsy. Rat prostate cell membrane chromatography combined with liquid chromatography-mass spectrometry (LC-MS) was used to identify active constituents from U. rhynchophylla extracts. Four compounds (corynoxeine, isorhynchophylline, isocorynoxeine and rhynchophylline) were discovered. Competitive binding assay results indicated that the four compounds were in direct competition at a single common binding site and interacted with α1A adrenergic receptors (α1A-AR) in a manner similar to tamsulosin. Affinity constant values of the four compounds binding with α1A-AR were also measured using rat prostate cell membrane chromatography (CMC). Finally, their pharmacodynamic effects were tested on rat caudal arteries. This CMC combined LC-MS system offers a means of drug discovery by screening natural medicinal herbs for new pharmacologically active molecules targeting specific receptors.
Preprocessing and Analysis of LC-MS-Based Proteomic Data
Tsai, Tsung-Heng; Wang, Minkun; Ressom, Habtom W.
2016-01-01
Liquid chromatography coupled with mass spectrometry (LC-MS) has been widely used for profiling protein expression levels. This chapter is focused on LC-MS data preprocessing, which is a crucial step in the analysis of LC-MS based proteomics. We provide a high-level overview, highlight associated challenges, and present a step-by-step example for analysis of data from LC-MS based untargeted proteomic study. Furthermore, key procedures and relevant issues with the subsequent analysis by multiple reaction monitoring (MRM) are discussed. PMID:26519169
Comparative shotgun proteomics using spectral count data and quasi-likelihood modeling.
Li, Ming; Gray, William; Zhang, Haixia; Chung, Christine H; Billheimer, Dean; Yarbrough, Wendell G; Liebler, Daniel C; Shyr, Yu; Slebos, Robbert J C
2010-08-06
Shotgun proteomics provides the most powerful analytical platform for global inventory of complex proteomes using liquid chromatography-tandem mass spectrometry (LC-MS/MS) and allows a global analysis of protein changes. Nevertheless, sampling of complex proteomes by current shotgun proteomics platforms is incomplete, and this contributes to variability in assessment of peptide and protein inventories by spectral counting approaches. Thus, shotgun proteomics data pose challenges in comparing proteomes from different biological states. We developed an analysis strategy using quasi-likelihood Generalized Linear Modeling (GLM), included in a graphical interface software package (QuasiTel) that reads standard output from protein assemblies created by IDPicker, an HTML-based user interface to query shotgun proteomic data sets. This approach was compared to four other statistical analysis strategies: Student t test, Wilcoxon rank test, Fisher's Exact test, and Poisson-based GLM. We analyzed the performance of these tests to identify differences in protein levels based on spectral counts in a shotgun data set in which equimolar amounts of 48 human proteins were spiked at different levels into whole yeast lysates. Both GLM approaches and the Fisher Exact test performed adequately, each with their unique limitations. We subsequently compared the proteomes of normal tonsil epithelium and HNSCC using this approach and identified 86 proteins with differential spectral counts between normal tonsil epithelium and HNSCC. We selected 18 proteins from this comparison for verification of protein levels between the individual normal and tumor tissues using liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MRM-MS). This analysis confirmed the magnitude and direction of the protein expression differences in all 6 proteins for which reliable data could be obtained. Our analysis demonstrates that shotgun proteomic data sets from different tissue phenotypes are sufficiently rich in quantitative information and that statistically significant differences in proteins spectral counts reflect the underlying biology of the samples.
Köke, Niklas; Zahn, Daniel; Knepper, Thomas P; Frömel, Tobias
2018-03-01
Analysis of polar organic chemicals in the aquatic environment is exacerbated by the lack of suitable and widely applicable enrichment methods. In this work, we assessed the suitability of a novel combination of well-known solid-phase extraction (SPE) materials in one cartridge as well as an evaporation method and for the enrichment of 26 polar model substances (predominantly log D < 0) covering a broad range of physico-chemical properties in three different aqueous matrices. The multi-layer solid-phase extraction (mlSPE) and evaporation method were investigated for the recovery and matrix effects of the model substances and analyzed with hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). In total, 65% of the model substances were amenable (> 10% recovery) to the mlSPE method with a mean recovery of 76% while 73% of the model substances were enriched with the evaporation method achieving a mean recovery of 78%. Target and non-target screening comparison of both methods with a frequently used reversed-phase SPE method utilizing "hydrophilic and lipophilic balanced" (HLB) material was performed. Target analysis showed that the mlSPE and evaporation method have pronounced advantages over the HLB method since the HLB material retained only 30% of the model substances. Non-target screening of a ground water sample with the investigated enrichment methods showed that the median retention time of all detected features on a HILIC system decreased in the order mlSPE (3641 features, median t R 9.7 min), evaporation (1391, 9.3 min), HLB (4414, 7.2 min), indicating a higher potential of the described methods to enrich polar analytes from water compared with HLB-SPE. Graphical abstract Schematic of the method evaluation (recovery and matrix effects) and method comparison (target and non-target analysis) of the two investigated enrichment methods for very polar chemicals in aqueousmatrices.
Chen, Tsung-Chi; Fillmore, Thomas L.; Prost, Spencer A.; Moore, Ronald J.; Ibrahim, Yehia M.; Smith, Richard D.
2016-01-01
The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher-pressure regions (e.g., ion source interfaces) of mass spectrometers, thus providing increased sensitivity. An “off-axis” ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to-charge ratios. In this study, a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadrupole mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at a pressure of 9–10 Torr. Key factors for the HPIF performance characterized included the effects of RF amplitude, the DC gradient, and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. The sensitivity enhancement in liquid chromatography selected reaction monitoring (LC-SRM) analyses of low-abundance peptides spiked into a highly complex mixture was also compared with that obtained using both a commercial S-lens interface and an in-line dual-ion funnel interface. PMID:26107611
Jin, Jing; Li, Yun; Zhang, Zhiping; Su, Fan; Qi, Peipei; Lu, Xianbo; Chen, Jiping
2011-12-23
A new method for the selective cleanup of complex matrices and simultaneous separation of benzo[a]pyrene (BaP) was developed in this study. This method was based on solid-phase extraction (SPE) using magnesium oxide microspheres as sorbents, and it eliminated interferences from various impurities, such as lipids, sulphur, pigments, halobenzenes, polychlorodibenzo-p-dioxins and polychlorodibenzofurans. Several parameters, including the volume of rinsing and eluting solvents, the type of loading solvents and SPE sorbents, were optimized systematically. The capability for impurity removal was verified by gel permeation chromatography, gas chromatography, and liquid chromatography. Compared to commercial sorbents (silica gel, florisil and alumina), MgO microspheres exhibited excellent performance in the selective isolation of BaP and removal of impurities. The proposed method was applied to detect BaP in complex samples (sediments, soils, fish, and porcine liver). The limit of quantification (LOQ) was 1.04 ngL(-1), and the resulting regression coefficient (r(2)) was greater than 0.999 over a broad concentration range (9.5-7600 ngL(-1)). In contrast to traditional methods, the proposed method can give rise to higher recovery (85.1-100.8%) and better selectivity with simpler operation and less consumption of organic solvents (20-40 mL). Copyright © 2011 Elsevier B.V. All rights reserved.
pH-Driven Ordering Transitions in Liquid Crystal Induced by Conformational Changes of Cardiolipin.
Sidiq, Sumyra; Verma, Indu; Pal, Santanu Kumar
2015-04-28
We report an investigation of interfacial phenomena occurring at aqueous-liquid crystal (LC) interfaces that triggers an orientational ordering transition of the LC in the presence of cardiolipin (CL) by varying pH, salt concentration and valence. In particular, the effects of three different conformational isomeric forms of the CL are observed to cause the response of the LC ordering to vary significantly from one to another at those interfaces. An ordering transition of the LC was observed when the CL is mostly in undissociated (at pH 2) and/or in bicyclic (at pH 4) conformation in which LC shows changes in the optical appearance from bright to dark. By contrast, no change in the optical appearance of the LC was observed when the pH of the system increases to 8 or higher in which the CL mostly exists in the open conformation. Fluorescence microscopy measurements further suggest that pH-dependent conformational forms of the CL have different ability to self-assemble (thus different packing efficiency) at aqueous-LC interfaces leading to dissimilar orientational behavior of the LC. Specifically, we found that change in headgroup-headgroup repulsion of the central phosphatidyl groups of the CL plays a key role in tuning the lipid packing efficiency and thus responses to interfacial phenomena. Orientational ordering transition of the LC was also observed as a function of increasing the ionic strength (buffer capacity) and strongly influenced in the presence of mono and divalent cations. Langmuir-Blodgett (LB) and polarization modulation infrared reflection absorption spectroscopy (PM-IRRAS) measurements provide further insight in modulation of the lipid packing efficiency and alkyl chain conformation of the CL at different pH and ionic conditions. Overall, the results presented in this paper establish that LCs offer a promising approach to differentiate different conformations (label free detection) of the CL through ordering transition of the LC at aqueous-LC interfaces.
Effect of Genetic Database Comprehensiveness on Fractional Proteomics of Escherichia coli O157:H7
2014-01-01
proteins would be observed in the extracellular fraction. 15. SUBJECT TERMS Escherichia coli O157:H7 Liquid chromatography Mass spectrometry...Preparation ...............1 2.2 Liquid Chromatography /Mass Spectrometry Sample Preparation ....................2 2.3 Liquid Chromatography /Mass... Chromatography /Mass Spectrometry Sample Preparation. Samples were prepared for liquid chromatography tandem mass spectrometry (LC-MS/MS) in a similar
Riley, Stephanie M; Ahoor, Danika C; Regnery, Julia; Cath, Tzahi Y
2018-02-01
Dissolved organic matter (DOM) present in oil and gas (O&G) produced water and fracturing flowback was characterized and quantified by multiple analytical techniques throughout a hybrid biological-physical treatment process. Quantitative and qualitative analysis of DOM by liquid chromatography - organic carbon detection (LC-OCD), liquid chromatography-high-resolution mass spectrometry (LC-HRMS), gas chromatography-mass spectrometry (GC-MS), and 3D fluorescence spectroscopy, demonstrated increasing removal of all groups of DOM throughout the treatment train, with most removal occurring during biological pretreatment and some subsequent removal achieved during membrane treatment. Parallel factor analysis (PARAFAC) further validated these results and identified five fluorescent components, including DOM described as humic acids, fulvic acids, proteins, and aromatics. Tryptophan-like compounds bound by complexation to humics/fulvics were most difficult to remove biologically, while aromatics (particularly low molecular weight neutrals) were more challenging to remove with membranes. Strong correlation among PARAFAC, LC-OCD, LC-HRMS, and GC-MS suggests that PARAFAC can be a quick, affordable, and accurate tool for evaluating the presence or removal of specific DOM groups in O&G wastewater. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Xiangrong; Zhang, Dan; Xu, Jinghua; Gu, Jingkai; Zhao, Yuqing
2007-10-15
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of 20(R)-dammarane-3beta,12beta,20,25-tetrol (25-OH-PPD) in rat. Ginsenoside Rh(2) was employed as an internal standard. The plasma samples were pretreated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. The mobile phase consisted of methanol-acetonitrile-10 mmol/l aqueous ammonium acetate (42.5:42.5:15, v:v:v), which was pumped at 0.4 ml/min. The analytical column (50 mm x 2.1 mm i.d.) was packed with Venusil XBP C8 material (3.5 microm). The standard curve was linear from 10 to 3000 ng/ml. The assay was specific, accurate (accuracy between -1.19 and 2.57% for all quality control samples), precise and reproducible (within- and between-day precisions measured as relative standard deviation were <5% and <7%, respectively). 25-OH-PPD in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 6h. The method had a lower limit of quantitation of 10 ng/ml, which offered a satisfactory sensitivity for the determination of (25-OH-PPD) in plasma. This quantitation method was successfully applied to pharmacokinetic studies of 25-OH-PPD after both an oral and an intravenous administration to rats and the absolute bioavailability is 64.8+/-14.3%.
Crews, Colin
2015-01-01
The principles and application of established and newer methods for the quantitative and semi-quantitative determination of ergot alkaloids in food, feed, plant materials and animal tissues are reviewed. The techniques of sampling, extraction, clean-up, detection, quantification and validation are described. The major procedures for ergot alkaloid analysis comprise liquid chromatography with tandem mass spectrometry (LC-MS/MS) and liquid chromatography with fluorescence detection (LC-FLD). Other methods based on immunoassays are under development and variations of these and minor techniques are available for specific purposes. PMID:26046699
Bernardy, Jeffry A.; Hubert, Terrance D.; Ogorek, Jacob M.; Schmidt, Larry J.
2013-01-01
An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples ≥500 ng/L and 4.8 to 17% RSD with samples ≤100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.
Barker, S A; Littlefield-Chabaud, M A; David, C
2001-02-10
A method for the solid-phase extraction (SPE) and liquid chromatographic-atmospheric pressure chemical ionization-mass spectrometric-mass spectrometric-isotope dilution (LC-APcI-MS-MS-ID) analysis of the indole hallucinogens N,N-dimethyltryptamine (DMT) and 5-methoxy DMT (or O-methyl bufotenin, OMB) from rat brain tissue is reported. Rats were administered DMT or OMB by the intraperitoneal route at a dose of 5 mg/kg and sacrificed 15 min post treatment. Brains were dissected into discrete areas and analyzed by the methods described as a demonstration of the procedure's applicability. The synthesis and use of two new deuterated internal standards for these purposes are also reported.