Sample records for chromatography-electroantennogram detection gc-ead

  1. An automated approach to detecting signals in electroantennogram data

    Treesearch

    D.H. Slone; B.T. Sullivan

    2007-01-01

    Coupled gas chromatography/electroantennographic detection (GC-EAD) is a widely used method for identifying insect olfactory stimulants present in mixtures of volatiles, and it can greatly accelerate the identification of insect semiochemicals. In GC-EAD, voltage changes across an insect's antenna are measured while the antenna is exposed to compounds eluting fi-...

  2. An automated approach to detecting signals in electroantennogram data

    USGS Publications Warehouse

    Slone, D.H.; Sullivan, B.T.

    2007-01-01

    Coupled gas chromatography/electroantennographic detection (GC-EAD) is a widely used method for identifying insect olfactory stimulants present in mixtures of volatiles, and it can greatly accelerate the identification of insect semiochemicals. In GC-EAD, voltage changes across an insect's antenna are measured while the antenna is exposed to compounds eluting from a gas chromatograph. The antenna thus serves as a selective GC detector whose output can be compared to that of a "general" GC detector, commonly a flame ionization detector. Appropriate interpretation of GC-EAD results requires that olfaction-related voltage changes in the antenna be distinguishable from background noise that arises inevitably from antennal preparations and the GC-EAD-associated hardware. In this paper, we describe and compare mathematical algorithms for discriminating olfaction-generated signals in an EAD trace from background noise. The algorithms amplify signals by recognizing their characteristic shape and wavelength while suppressing unstructured noise. We have found these algorithms to be both powerful and highly discriminatory even when applied to noisy traces where the signals would be difficult to discriminate by eye. This new methodology removes operator bias as a factor in signal identification, can improve realized sensitivity of the EAD system, and reduces the number of runs required to confirm the identity of an olfactory stimulant. ?? 2007 Springer Science+Business Media, LLC.

  3. Identification of host fruit volatiles from snowberry (Symphoricarpos albus), attractive to Rhagoletis zephyria flies from Western United States

    USDA-ARS?s Scientific Manuscript database

    Gas chromatography coupled with electroantennogram detection (GC-EAD) was used to identify volatiles from the fruit of Snowberry, Symphoricarpos albus laevigatus, as key attractants for Rhagoletis zephyria flies reared from snowberry fruit. A nine-component blend containing 3-methylbutan-1-ol (3%), ...

  4. Identification (GC and GC-MS) of unsaturated acetates in Elasmopalpus lignosellus and their biological activity (GC-EAD and EAG).

    PubMed

    Jham, Gulab N; da Silva, Alexsandro A; Lima, Eraldo R; Viana, Paulo

    2005-02-01

    Two insect colonies of Elasmopalpus lignosellus were reared in our laboratory, the first being initiated from pupae obtained from a cornfield in the region of Sete Lagoas, Minas Gerais and the second from a cornfield in the region of Goiânia, Goiás. From the two colonies, two extracts were prepared from the pheromone glands of virgin E. lignosellus females. The extract obtained from the first colony was designated as extract 1 while the extract obtained from the second colony was designated as extract 2. Extract 1 was analyzed by gas chromatography-mass spectrometry (GC-MS) with (Z)-9-hexadecenyl acetate [(Z)-9-HDA] and (Z)-11-hexadecenyl acetate [(Z)-11-HDA] being identified and confirmed by the formation of DMDS derivatives. In addition, a third acetate, which could be either (E)-8-hexadecenyl acetate [(E)-8-HDA] or (E)-9-hexadecenyl acetate [(E)-9-HDA] was detected by GC-MS. Extract 2 was analyzed by gas chromatography (GC) and gas chromatography-electroannetography (GC-EAD) revealing the presence of (Z)-11-HDA and (Z)-9-TDA. In addition, the same compounds elicited a response with the E. lignosellus male antenna obtained from the second insect colony. Electroantennography (EAG) screening with the male E. lignosellus antenna (obtained from the second insect colony) was conducted with the 23 possible tetradecenyl acetates (TDA) and 22 hexadecenyl acetates (HDA) as standards. Out of the 23 TDA isomers evaluated, only (Z)-9-TDA elicited a response and out of the 22 HDA [(Z) and (E) isomers gamma2 to delta13] evaluated only (Z)-11-HDA elicited a response. The acetate compositions of two extracts obtained from insects originating from the two states (Minas Gerais and Goiás) of Brazil were different from one another as well as from that obtained from insects in Tifton, GA, USA. The bioactivity data (GC-EAD) of the extract 2 differed from those reported for the Tifton, GA, USA population. These data suggest polymorphism in relation to the insect populations found in

  5. Equations for nickel-chromium wire heaters of column transfer lines in gas chromatographic-electroantennographic detection (GC-EAD).

    PubMed

    Byers, John A

    2004-05-30

    Heating of chromatographic columns, transfer lines, and other devices is often required in neuroscience research. For example, volatile compounds passing through a capillary column of a gas chromatograph (GC) can be split, with half exiting the instrument through a heated transfer line to an insect antenna or olfactory sensillum for electroantennographic detector (GC-EAD) recordings. The heated transfer line is used to prevent condensation of various chemicals in the capillary that would otherwise occur at room temperature. Construction of such a transfer line heater is described using (80/20%) nickel-chromium heating wire wrapped in a helical coil and powered by a 120/220 V ac rheostat. Algorithms were developed in a computer program to estimate the voltage at which a rheostat should be set to obtain the desired heater temperature for a specific coil. The coil attributes (radius, width, number of loops, or length of each loop) are input by the user, as well as AWG size of heating wire and desired heater temperature. The program calculates total length of wire in the helix, resistance of the wire, amperage used, and the voltage to set the rheostat. A discussion of semiochemical isolation methods using the GC-EAD and bioassays is presented.

  6. Female-biased attraction of Oriental fruit fly, bactrocera dorsalis (Hendel), to a blend of host fruit volatiles from Terminalia catappa L.

    PubMed

    Siderhurst, Matthew S; Jang, Eric B

    2006-11-01

    Coupled gas chromatography-electroantennogram detection (GC-EAD) analysis of volatiles from tropical almond fruit, Terminalia catappa L., revealed 22 compounds that were detected by antennae of oriental fruit fly females, Bactrocera dorsalis (Hendel). Both solid-phase microextraction (SPME) and Porapak Q were used for sampling odors in fruit headspace, with SPME collections producing larger EAD responses from a greater number of compounds. Geranyl acetate and methyl eugenol elicited the largest EAD responses. A synthetic blend containing SPME collected, EAD stimulatory compounds showed female-biased attraction in laboratory wind tunnel bioassays, but heavily male-biased trap captures in a larger olfactometer arena. A nine-component subset of compounds eliciting relatively small EAD responses (EAD minor) and consisting of equal parts ethanol, ethyl acetate, ethyl hexanoate, hexyl acetate, linalyl acetate, ethyl nonanate, nonyl acetate, ethyl cinnamate, and (E)-beta-farnesene, attracted mainly females. This EAD minor blend was as attractive to females and much less attractive to males when compared to torula yeast in field cage experiments using glass McPhail traps. Similar results were obtained with outdoor rotating olfactometer tests in which the EAD minor blend was almost completely inactive for males.

  7. Identification by GC-EAD of the two-component trail-following pheromone of Prorhinotermes simplex (Isoptera, Rhinotermitidae, Prorhinotermitinae).

    PubMed

    Sillam-Dussès, David; Kalinová, Blanka; Jiros, Pavel; Brezinová, Anna; Cvacka, Josef; Hanus, Robert; Sobotník, Jan; Bordereau, Christian; Valterová, Irena

    2009-08-01

    GC/MS analysis confirmed that neocembrene is the major component of the trail pheromone in the three species of the termite genus Prorhinotermes (P. simplex, P. canalifrons, P. inopinatus). In addition, EAG and GC-EAD experiments with P. simplex strongly suggest that dodecatrienol is a quantitatively minor component but a qualitatively important component of this trail pheromone. Trail-following bioassays confirmed the two-component nature of the trail pheromone. This is the first report of the use of the GC-EAD for the identification of trail pheromone in termites. These original results underline once again the special phylogenetic status of the Prorhinotermitinae among Rhinotermitidae.

  8. Electroantennographic and behavioral responses of the sphinx moth Manduca sexta to host plant headspace volatiles.

    PubMed

    Fraser, Ann M; Mechaber, Wendy L; Hildebrand, John G

    2003-08-01

    Coupled gas chromatography with electroantennographic detection (GC-EAD) using antennae of adult female Manduca sexta was employed to screen for olfactory stimulants present in headspace collections from four species of larval host plants belonging to two families: Solanaceae--Lycopersicon esculentum (tomato), Capiscum annuum (bell pepper), and Datura wrightii; and Martyniaceae--Pronboscideaparviflora. Headspace volatiles were collected from undamaged foliage of potted, living plants. GC-EAD revealed 23 EAD-active compounds, of which 15 were identified by GC-mass spectrometry. Identified compounds included aliphatic, aromatic, and terpenoid compounds bearing a range of functional groups. Nine EAD-active compounds were common to all four host plant species: (Z)-3-hexenyl acetate, nonanal, decanal, phenylacetaldehyde, methyl salicylate, benzyl alcohol, geranyl acetone, (E)-nerolidol, and one unidentified compound. Behavioral responses of female moths to an eight-component synthetic blend of selected tomato headspace volatiles were tested in a laboratory wind tunnel. Females were attracted to the blend. A comparison of responses from antennae of males and females to bell pepper headspace volatiles revealed that males responded to the same suite of volatiles as females, except for (Z)-3-hexenyl benzoate. EAD responses of males also were lower for (Z)-and (E)-nerolidol and one unidentified compound. Electroantennogram EAG dose-response curves for the 15 identified EAD-active volatiles were recorded. At the higher test doses (10-100 microg), female antennae yielded larger EAG responses to terpenoids and to aliphatic and aromatic esters. Male antennae did respond to the higher doses of (Z)-3-hexenyl benzoate, indicating that they can detect this compound. On the basis of ubiquity of the EAD-active volatiles identified to date in host plant headspace collections, we suggest that M. sexta uses a suite of volatiles to locate and identify appropriate host plants.

  9. Methyl 2-(methylthio)benzoate: A sex attractant for the June beetles, Phyllophaga tristis and P. apicata

    USDA-ARS?s Scientific Manuscript database

    Male antennae of Phyllophaga tristis (Fabricius) (Coleoptera: Scarabaeidae: Melolonthinae) were tested using a coupled gas chromatograph-electroantennogram detector (GC-EAD) system for electrophysiological responses to five sex pheromones identified from other Phyllophaga species including L-valine ...

  10. Two compounds in bed bug feces are sufficient to elicit off-host aggregation by bed bugs, Cimex lectularius.

    PubMed

    Olson, Joelle F; Vers, Leonard M Ver; Moon, Roger D; Kells, Stephen A

    2017-01-01

    After feeding, bed bugs aggregate in cracks and crevices near a host. Aggregation and arrestment are mediated by tactile and chemical stimuli associated with the bugs' feces and exuviae. Volatiles derived from fecally stained filter papers were analyzed by solid-phase microextraction (SPME) and evaluated using a multichoice behavioral assay to determine their impact on bed bug aggregation. In addition, crude fecal extracts were collected in methanol, analyzed by gas chromatography coupled with electroantennogram detection (GC-EAD) and mass spectrometry (GC-MS) and evaluated in open-air multichoice behavioral assays. The SPME method was used to detect (E)-2-hexenal and (E)-2-octenal in heated bed bug feces. The presence of these two volatile components did not affect aggregation. Analysis of the crude fecal extracts revealed several semi-volatile nitrogenous compounds, a carboxylic acid and a sulfur-based compound. Adult antennae responded to compounds eluted from three regions of the crude extract using GC-EAD. A combination of two compounds, dimethyl trisulfide and methyldiethanolamine, resulted in aggregation responses equivalent to the original crude extract. Bed bug aggregation is mediated by semi-volatile compounds derived from fecal extracts, and two compounds are sufficient to elicit aggregation. The two compounds identified here could be used to enhance the effectiveness of insecticidal applications or improve monitoring techniques. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  11. Gas Chromatography Analysis with Olfactometric Detection (GC-O) as a Useful Methodology for Chemical Characterization of Odorous Compounds

    PubMed Central

    Brattoli, Magda; Cisternino, Ezia; Dambruoso, Paolo Rosario; de Gennaro, Gianluigi; Giungato, Pasquale; Mazzone, Antonio; Palmisani, Jolanda; Tutino, Maria

    2013-01-01

    The gas chromatography-olfactometry (GC-O) technique couples traditional gas chromatographic analysis with sensory detection in order to study complex mixtures of odorous substances and to identify odor active compounds. The GC-O technique is already widely used for the evaluation of food aromas and its application in environmental fields is increasing, thus moving the odor emission assessment from the solely olfactometric evaluations to the characterization of the volatile components responsible for odor nuisance. The aim of this paper is to describe the state of the art of gas chromatography-olfactometry methodology, considering the different approaches regarding the operational conditions and the different methods for evaluating the olfactometric detection of odor compounds. The potentials of GC-O are described highlighting the improvements in this methodology relative to other conventional approaches used for odor detection, such as sensoristic, sensorial and the traditional gas chromatographic methods. The paper also provides an examination of the different fields of application of the GC-O, principally related to fragrances and food aromas, odor nuisance produced by anthropic activities and odorous compounds emitted by materials and medical applications. PMID:24316571

  12. Forensic Drug Identification, Confirmation, and Quantification Using Fully Integrated Gas Chromatography with Fourier Transform Infrared and Mass Spectrometric Detection (GC-FT-IR-MS).

    PubMed

    Lanzarotta, Adam; Lorenz, Lisa; Voelker, Sarah; Falconer, Travis M; Batson, JaCinta S

    2018-05-01

    This manuscript is a continuation of a recent study that described the use of fully integrated gas chromatography with direct deposition Fourier transform infrared detection and mass spectrometric detection (GC-FT-IR-MS) to identify and confirm the presence of sibutramine and AB-FUBINACA. The purpose of the current study was to employ the GC-FT-IR portion of the same instrument to quantify these compounds, thereby demonstrating the ability to identify, confirm, and quantify drug substances using a single GC-FT-IR-MS unit. The performance of the instrument was evaluated by comparing quantitative analytical figures of merit to those measured using an established, widely employed method for quantifying drug substances, high performance liquid chromatography with ultraviolet detection (HPLC-UV). The results demonstrated that GC-FT-IR was outperformed by HPLC-UV with regard to sensitivity, precision, and linear dynamic range (LDR). However, sibutramine and AB-FUBINACA concentrations measured using GC-FT-IR were not significantly different at the 95% confidence interval compared to those measured using HPLC-UV, which demonstrates promise for using GC-FT-IR as a semi-quantitative tool at the very least. The most significant advantage of GC-FT-IR compared to HPLC-UV is selectivity; a higher level of confidence regarding the identity of the analyte being quantified is achieved using GC-FT-IR. Additional advantages of using a single GC-FT-IR-MS instrument for identification, confirmation, and quantification are efficiency, increased sample throughput, decreased consumption of laboratory resources (solvents, chemicals, consumables, etc.), and thus cost.

  13. Identification of mosquito repellent odours from Ocimum forskolei.

    PubMed

    Dekker, Teun; Ignell, Rickard; Ghebru, Maedot; Glinwood, Robert; Hopkins, Richard

    2011-09-22

    Native mosquito repellent plants have a good potential for integrated mosquito control in local settings. Ocimum forskolei, Lamiaceae, is used in Eritrea as a spatial mosquito repellent inside houses, either through crushing fresh plants or burning dry plants. We verified whether active repellent compounds could be identified using gas-chromatography coupled electroantennogram recordings (GC-EAD) with headspace extracts of crushed plants. EAD active compounds included (R)-(-)-linalool, (S)-(+)-1-octen-3-ol, trans-caryophyllene, naphthalene, methyl salicylate, (R)-(-)-α-copaene, methyl cinnamate and (E)-ocimene. Of these compounds (R)-(-)-linalool, methyl cinnamate and methyl salicylate reduced landing of female Aedes aegypti on human skin-odor baited tubes. The latter two are novel mosquito repellent compounds. The identification of mosquito repellent compounds contributes to deciphering the mechanisms underlying repulsion, supporting the rational design of novel repellents. The three mosquito repellent compounds identified in this study are structurally dissimilar, which may indicate involvement of different sensory neurons in repulsion. Repulsion may well be enhanced through combining different repellent plants (or their synthetic mimics), and can be a locally sustainable part in mosquito control efforts.

  14. Analysis of fragrance compounds in blood samples of mice by gas chromatography, mass spectrometry, GC/FTIR and GC/AES after inhalation of sandalwood oil.

    PubMed

    Jirovetz, L; Buchbauer, G; Jäger, W; Woidich, A; Nikiforov, A

    1992-01-01

    After inhalation experiments with sandalwood oil and the pure fragrance compounds coumarin and alpha-terpineol, substances were detected and measured in the blood samples of test animals (mice) using gas chromatography/mass spectrometry (GC/MS) (MID) in connection with GC/FTIR (SWC), GC/AES (carbon and oxygen trace) and flame ionization detection/gas chromatography. Using tiglinic acid benzyl ester as the internal standard the following concentrations in serum could be found: alpha-santalol 6.1 ng/mL, beta-santalol 5.3 ng/mL and alpha-santalene 0.5 ng/mL. In separate inhalation experiments with coumarin and with alpha-terpineol the corresponding concentrations were 7.7 ng/mL and 6.9 ng/mL, respectively.

  15. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    PubMed

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  16. Detection of virgin coconut oil adulteration with animal fats using quantitative cholesterol by GC × GC-TOF/MS analysis.

    PubMed

    Xu, Baocheng; Li, Peiwu; Ma, Fei; Wang, Xiuping; Matthäus, Bertrand; Chen, Ran; Yang, Qingqing; Zhang, Wen; Zhang, Qi

    2015-07-01

    A new method based on the cholesterol level was developed to detect the presence of animal fats in virgin coconut oil (VCO). In this study, the sterols in VCO and animal fats was separated using conventional one-dimensional gas chromatography (1D GC) and comprehensive two-dimensional gas chromatography (GC×GC). Compared with 1D GC, the GC×GC system could obtain a complete baseline separation of the sterol trimethylsilyl ethers derived from cholesterol and cholestanol, so that the cholesterol content in pure VCO and false VCO adulterated with animal fats could be accurately determined. Cholesterol, a main sterol found in animal fats, represented less than 5mg/kg of VCO. The study demonstrated that the determination of the cholesterol level in VCO could be used for reliable detection of the presence of lard, chicken fat, mutton tallow, beef tallow, or their mixture in VCO at a level as little as 0.25%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A sharp, robust, and quantitative method by liquid chromatography tandem mass spectrometry for the measurement of EAD for acute radiation syndrome and its application.

    PubMed

    Zhang, Yiwei; Li, Jian; Meng, Zhiyun; Zhu, Xiaoxia; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Zheng, Ying; Wei, Jinbin; Dou, Guifang

    2017-06-15

    17-Ethinyl-3,17-dihydroxyandrost-5-ene (EAD) is an agent designed for the treatment of acute radiation syndrome (ARS). Given its vital role played in the prevention and mitigation of ARS, the development of a sharp, sensitive and robust liquid chromatography tandem mass spectrometry (LC-MS/MS) method to monitor the metabolism of EAD in vivo was crucial. A new method was constructed and validated for the determination of EAD with the internal standard of androst-5-ene-3β,17β-diol (5-AED). The blood samples were precipitated with methanol, centrifuged, from which the supernatant was separated on UPLC with C18 column and eluted in gradient with acetonitrile and Milli-Q water both containing 0.1% formic acid (FA). Quantification was performed by a triple quadrupole mass spectrometer with electro spray ionization (ESI) in multiple reactive monitoring (MRM) positive mode. A good linearity was obtained with R>0.99 for EAD within its calibration range from 5 to 1000ngmL -1 with a lowest limit of quantification (LLOQ) of 5ngmL -1 . Inter- and intra-day accuracy and precision of three levels of quality control (QC) samples were within the range of 15%, while the LLOQ was within 20%. Samples were stable under the circumstances of the experiments. The method was simple, accurate and robust applied to determine the concentrations of EAD in Wistar rat after a single administration of EAD orally at the dose of 100mgkg -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Identification of mosquito repellent odours from Ocimum forskolei

    PubMed Central

    2011-01-01

    Background Native mosquito repellent plants have a good potential for integrated mosquito control in local settings. Ocimum forskolei, Lamiaceae, is used in Eritrea as a spatial mosquito repellent inside houses, either through crushing fresh plants or burning dry plants. We verified whether active repellent compounds could be identified using gas-chromatography coupled electroantennogram recordings (GC-EAD) with headspace extracts of crushed plants. Results EAD active compounds included (R)-(-)-linalool, (S)-(+)-1-octen-3-ol, trans-caryophyllene, naphthalene, methyl salicylate, (R)-(-)-α-copaene, methyl cinnamate and (E)-ocimene. Of these compounds (R)-(-)-linalool, methyl cinnamate and methyl salicylate reduced landing of female Aedes aegypti on human skin-odor baited tubes. The latter two are novel mosquito repellent compounds. Conclusions The identification of mosquito repellent compounds contributes to deciphering the mechanisms underlying repulsion, supporting the rational design of novel repellents. The three mosquito repellent compounds identified in this study are structurally dissimilar, which may indicate involvement of different sensory neurons in repulsion. Repulsion may well be enhanced through combining different repellent plants (or their synthetic mimics), and can be a locally sustainable part in mosquito control efforts. PMID:21936953

  19. Application of comprehensive multidimensional gas chromatography combined with time-of-flight mass spectrometry (GC x GC-TOFMS) for high resolution analysis of hop essential oil.

    PubMed

    Roberts, Mark T; Dufour, Jean-Pierre; Lewis, Alastair C

    2004-04-01

    The selection and quality of hops is a major determinant in beer flavour. Brewers acknowledge that distinctive characteristics of different hop varieties can be traced to the composition of their essential oils. The difficulty in characterising complex mixtures such as hop oil using 1-D chromatography is that many compounds co-elute. With the introduction of comprehensive multidimensional capillary gas chromatography (GC x GC), there is a tremendous improvement in the separation power or peak capacity. Recent work using GC x GC with flame ionisation detection has suggested that there may be over 1,000 compounds in hop oil. This work describes the use of GC x GC combined with TOFMS detection (Leco Pegasus 4D instrument) to analyse Target hop oil. The TOFMS spectral acquisition rate of 60 Hz provided sufficient spectra per peak (2-D peak base width of 0.1-0.2 s) for identification (119 components were identified with 45 previously unreported compounds). When analysing results, an advantage of GC x GC coupled to TOFMS is that 2-D chromatograms can be viewed for individual masses that are characteristic of particular functional groups. This allows the analyst to view the various homologous series of compounds although in certain cases coelution may still be present as shown by the esters with mass 75.

  20. Identification and field evaluation of pear fruit volatiles attractive to the oriental fruit moth, Cydia molesta.

    PubMed

    Lu, Peng-Fei; Huang, Ling-Qiao; Wang, Chen-Zhu

    2012-08-01

    Plant volatiles play a key role in host plant location of phytophagous insects. Cydia molesta is an important pest of pear fruit late in the growing season. We identified and quantified volatiles from immature and mature fruits of six pear varieties by using gas chromatography-mass spectrometry (GC-MS). Attractiveness of synthetic blends to adults based on gas chromatography-electroantennogram detection (GC-EAD) activity was investigated in both field and laboratory. Consistent electroantennographic activity was obtained for 12 compounds from headspace collections of the mature fruits of the six pear varieties. Qualitative and quantitative differences were found among six odor profiles. Among the six mixtures, the mixture of 1-hexanol, nonanal, ethyl butanoate, butyl acetate, ethyl hexanoate, hexyl acetate, hexyl butanoate, and farnesene (different isomers) with a 1:1:100:70:7:5:1:4 ratio from the variety Jimi and the mixture of nonanal, ethyl butanoate, 3-methylbutyl acetate, ethyl hexanoate, hexyl acetate, and farnesene with a 1:100:1:32:1:2 ratio from the variety Huangjin were highly attractive to both sexes in the field. However, male captures were much higher than those of females. Further wind tunnel tests proved that both sexes exhibited upwind flight to the lures, but only males landed on the source. Our finding indicates that mixtures mimicking Jimi and Huangjin volatiles attract both females and males of C. molesta, and these host volatiles may be involved in mate finding behavior.

  1. ENVIRONMENTAL APPLICATION OF GAS CHROMATOGRAPHY/ATOMIC EMISSION DETECTION

    EPA Science Inventory

    A gas chromatography/atomic emission detector (GC/AED) system has been evaluated for its applicability to environmental analysis. Detection limits, elemental response factors, and regression analysis data were determined for 58 semivolatile environmental contaminants. Detection l...

  2. Gas chromatography-mass spectrometry (GC-MS) analysis of extractives of naturally durable wood

    Treesearch

    G.T. Kirker; A.B. Blodgett; S.T. Lebow; C.A. Clausen

    2011-01-01

    A preliminary study to evaluate naturally durable wood species in an above ground field trial using Gas Chromatography-Mass Spectrometry (GC-MS) detected differences in fatty acid extractives between species and within the same species over time. Fatty acids were extracted with chloroform: methanol mixture then methylated with sodium methoxide and fractionated using...

  3. Detection biomarkers of lung cancer using mini-GC-PID system integrated with micro GC column and micro pre-concentrator

    PubMed Central

    2014-01-01

    The survival rate of lung cancer can be significantly improved by monitoring biomarkers in exhaled air that indicate diseases in early stage, so it is very important to develop micro analytical systems which can offer a fast, on-site, real-time detecting biomarkers in exhaled air. In this paper, a mini-gas chromatography (GC)-photo-ionization detector (PID) system integrated with a micro GC column and a micro pre-concentrator was developed for forming an inexpensive, fast, and non-invasive diagnostic tool for lung cancer. This system has very strong concentrate ability owing to its integrated micro pre-concentrator, which make the detection of trace components in exhaled air very easy. In addition, the integrated micro GC column can separate complex mixtures, which overcome low resolution and poor anti-interference ability of other instruments. The results indicated that the mini-GC-PID system can effectively separate and detect the biomarkers at parts-per-billion (ppb) level. PMID:25339856

  4. Assessment of a combined gas chromatography mass spectrometer sensor (GC-MSS) system for detecting biologically relevant volatile compounds (VCs).

    PubMed

    Gould, Oliver; Wieczorek, Tomas; de Lacy Costello, Ben P J; Persad, Raj; Ratcliffe, Norman

    2017-09-26

    There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/ SnO2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These 2 different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. 29 chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but 2 instances the sensor exhibited the same or superior limit of detection compared to the MS. 12 stool samples from healthy participants were analysed, the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications. © 2017 IOP Publishing Ltd.

  5. Analysis of Listeria using exogenous volatile organic compound metabolites and their detection by static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS).

    PubMed

    Taylor, Carl; Lough, Fraser; Stanforth, Stephen P; Schwalbe, Edward C; Fowlis, Ian A; Dean, John R

    2017-07-01

    Listeria monocytogenes is a Gram-positive bacterium and an opportunistic food-borne pathogen which poses significant risk to the immune-compromised and pregnant due to the increased likelihood of acquiring infection and potential transmission of infection to the unborn child. Conventional methods of analysis suffer from either long turn-around times or lack the ability to discriminate between Listeria spp. reliably. This paper investigates an alternative method of detecting Listeria spp. using two novel enzyme substrates that liberate exogenous volatile organic compounds in the presence of α-mannosidase and D-alanyl aminopeptidase. The discriminating capabilities of this approach for identifying L. monocytogenes from other species of Listeria are investigated. The liberated volatile organic compounds (VOCs) are detected using an automated analytical technique based on static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS). The results obtained by SHS-MCC-GC-IMS are compared with those obtained by the more conventional analytical technique of headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The results found that it was possible to differentiate between L. monocytogenes and L. ivanovii, based on their VOC response from α-mannosidase activity.

  6. Electrophysiological response and attraction of emerald ash borer to green leaf volatiles (GLVs) emitted by host foliage.

    PubMed

    de Groot, Peter; Grant, Gary G; Poland, Therese M; Scharbach, Roger; Buchan, Linda; Nott, Reginald W; Macdonald, Linda; Pitt, Doug

    2008-09-01

    Green leaf volatiles (GLVs) function as host attractants, pheromone synergists, or sexual kairomones for a number of coleopteran folivores. Hence, we focused on host GLVs to determine if they were attractive to adults of the emerald ash borer, Agrilus planipennis (Coleoptera: Buprestidae), which feeds on ash (Fraxinus) foliage. Eight GLVs were identified by chromatography-electroantennogram (GC) and GC-mass spectrometry in foliar headspace volatiles collected in traps containing Super-Q from white ash, Fraxinus americana, and green ash, Fraxinus pennsylvanica, trees. GLVs in the aeration extracts elicited antennal responses from both male and female adults in gas chromatography-electroantennogram detection bioassays. Male antennae were more responsive than female antennae and showed the strongest response to (Z)-3-hexenol. Six field experiments were conducted in Canada and the USA from 2004 to 2006 to evaluate the attractiveness of candidate GLVs, in various lure combinations and dosages. Field experiments demonstrated that lures containing (Z)-3-hexenol were the most effective in increasing trap catch when placed on purple traps in open areas or along the edges of woodlots containing ash. Lures with (Z)-3-hexenol were more attractive to males than females, and dosage may be a factor determining its effectiveness.

  7. Comparison of traditional gas chromatography (GC), headspace GC, and the microbial identification library GC system for the identification of Clostridium difficile.

    PubMed Central

    Cundy, K V; Willard, K E; Valeri, L J; Shanholtzer, C J; Singh, J; Peterson, L R

    1991-01-01

    Three gas chromatography (GC) methods were compared for the identification of 52 clinical Clostridium difficile isolates, as well as 17 non-C. difficile Clostridium isolates. Headspace GC and Microbial Identification System (MIS) GC, an automated system which utilizes a software library developed at the Virginia Polytechnic Institute to identify organisms based on the fatty acids extracted from the bacterial cell wall, were compared against the reference method of traditional GC. Headspace GC and MIS were of approximately equivalent accuracy in identifying the 52 C. difficile isolates (52 of 52 versus 51 of 52, respectively). However, 7 of 52 organisms required repeated sample preparation before an identification was achieved by the MIS method. Both systems effectively differentiated C. difficile from non-C. difficile clostridia, although the MIS method correctly identified only 9 of 17. We conclude that the headspace GC system is an accurate method of C. difficile identification, which requires only one-fifth of the sample preparation time of MIS GC and one-half of the sample preparation time of traditional GC. PMID:2007632

  8. COMPARATIVE EVALUATION OF GC/MS (GAS CHROMATOGRAPHY/MASS SPECTROMETRY) DATA ANALYSIS PROCESSING

    EPA Science Inventory

    Mass spectra obtained by fused silica capillary gas chromatography/mass spectrometry/data system (GC/MS/DS) analysis of mixtures of organic chemicals adsorbed on Tenax GC cartridges was subjected to manual and automated interpretative techniques. Synthetic mixtures (85 chemicals ...

  9. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD).

    PubMed

    Bravo, Manuel; Lespes, Gaëtane; De Gregori, Ida; Pinochet, Hugo; Gautier, Martine Potin

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 mum PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L(-1) in water and close to ng (Sn) kg(-1) in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.

  10. A GC-MS method for the detection of toluene and ethylbenzene in volatile substance abuse.

    PubMed

    El-Haj, B M; Al-Amri, A M; Hassan, M H; Bin-Khadem, R K; Al-Hadi, A A

    2000-09-01

    The interference of some substances with the gas chromatography-flame ionization detection and gas chromatography-Fourier transform infrared detection of toluene and ethylbenzene in volatile substance abuse poses problems. A gas chromatography-mass spectrometry (GC-MS) method that will overcome such interference has been developed for the detection of toluene and/or ethylbenzene in the headspace of preparations and products containing these substances and in the headspace of blood samples in the cases of volatile substance abuse. The method is based on converting toluene to benzoic acid via the formation of benzotrichloride. The latter compound was obtained upon the reaction of toluene with chlorine gas under direct sunlight conditions. In the presence of water, benzotrichloride was converted to benzoic acid. Ethylbenzene was converted to benzoic acid and two phenylethanols via the formation of side chain chloro-substituted phenylethanes followed by reaction with water. The chloro-substituted phenylethanes were obtained by the reaction of ethylbenzene with chlorine under direct sunlight conditions. The benzoic acid resulting from toluene and/or ethylbenzene and the two phenylethanols resulting from ethylbenzene were detected by GC-MS as their trimethylsilyl (TMS) derivatives. For the method to be viable for the detection of volatile substance abuse, the chlorination reactions were effected in the gaseous state.

  11. Application of headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography (GC x GC) for the chemical profiling of volatile oils in complex herbal mixtures.

    PubMed

    Di, Xin; Shellie, Robert A; Marriott, Philip J; Huie, Carmen W

    2004-04-01

    The coupling of headspace solid-phase microextraction (HS-SPME) with comprehensive two-dimensional gas chromatography (GC x GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one-dimensional (1-D) GC, the improved analytical capabilities of GC x GC in terms of increased detection sensitivity and separation power were demonstrated by using HS-SPME/GC x GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2-D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2-D GC x GC plot.

  12. State-of-the art of selective detection and identification of I-, Br-, Cl-, and F-containing compounds in gas chromatography and liquid chromatography.

    PubMed

    Brede, Cato; Pedersen-Bjergaard, Stig

    2004-09-24

    This review article presents an overview of halogen-specific detection in gas chromatography (GC) and liquid chromatography (LC). Attention is primarily focused on the use of plasma emission spectroscopy and plasma mass spectrometry as detectors, but other halogen-selective detection principles are also mentioned. Different instrumental configurations are discussed both with respect to technical set-up and performance, the principal reasons for halogen-selective detection are highlighted, and recent applications are reviewed from areas such as environmental chemistry, petroleum characterization, and drug analysis.

  13. Behavioral and Antennal Responses of Drosophila suzukii (Diptera: Drosophilidae) to Volatiles From Fruit Extracts.

    PubMed

    Abraham, John; Zhang, Aijun; Angeli, Sergio; Abubeker, Sitra; Michel, Caryn; Feng, Yan; Rodriguez-Saona, Cesar

    2015-04-01

    Native to Southeast Asia, the spotted wing drosophila, Drosophila suzukii Matsumura (Diptera: Drosophilidae), has become a serious pest of soft-skinned fruit crops since its introduction into North America and Europe in 2008. Current monitoring strategies use baits based on fermentation products; however, to date, no fruit-based volatile blends attractive to this fly have been identified. This is particularly important because females are able to cut into the epicarp of ripening fruit for oviposition. Thus, we conducted studies to: 1) investigate the behavioral responses of adult D. suzukii to volatiles from blueberry, cherry, raspberry, and strawberry fruit extracts; 2) identify the antennally active compounds from the most attractive among the tested extracts (raspberry) using gas chromatography (GC)-mass spectrometry and coupled gas chromatography -electroantennographic detection (GC-EAD); and 3) test a synthetic blend containing the EAD-active compounds identified from raspberry extract on adult attraction. In olfactometer studies, both female and male D. suzukii were attracted to all four fruit extracts. The attractiveness of the fruit extracts ranks as: raspberry ≥ strawberry > blueberry ≥ cherry. GC analyses showed that the fruit extracts emit distinct volatile compounds. In GC-EAD experiments, 11 raspberry extract volatiles consistently elicited antennal responses in D. suzukii. In choice test bioassays, a synthetic EAD-active blend attracted more D. suzukii than a blank control, but was not as attractive as the raspberry extract. To our knowledge, this is the first report of a behaviorally and antennally active blend of host fruit volatiles attractive to D. suzukii, offering promising opportunities for the development of improved monitoring and behaviourally based management tools. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Seasonal variation of gastroprotective terpenoids in Maytenus robusta (Celastraceae) quantified by gas chromatography-flame ionization detection (GC-FID).

    PubMed

    Zermiani, Tailyn; Junior, Antonio A S; Ferreira, Renê A; Wagner, Theodoro M; Machado, Marina S; Cechinel-Filho, Valdir; Niero, Rivaldo

    2016-11-01

    The triterpenes friedelin (1), β-friedelinol (2) and 3,15-dioxo-21α-hydroxyfriedelane (3) in the aerial parts of Maytenus robusta, a Brazilian medicinal plant with antiulcer potential, were seasonally quantified by gas chromatography flame-ionization detection (GC-FID) using an external standard. The method was found to be linear, precise and sensitive. Compounds 1 and 2 were found in M. robusta leaves and branches, with highest concentrations in the leaves collected in autumn, i.e. 3.21 ± 0.16 and 12.60 ± 1.49 mg g-1 dry weight of 1 and 2, respectively. On the other hand, compound 3 was found only in the branches, with the highest concentrations in winter and autumn (0.21 ± 0.01 and 0.20 ± 0.02 mg g-1). The results allow to define the optimal season and plant parts for the collection of M. robusta as a phytotherapeutic drug.

  15. Development of the GC-MS organic aerosol monitor (GC-MS OAM) for in-field detection of particulate organic compounds

    NASA Astrophysics Data System (ADS)

    Cropper, Paul M.; Overson, Devon K.; Cary, Robert A.; Eatough, Delbert J.; Chow, Judith C.; Hansen, Jaron C.

    2017-11-01

    Particulate matter (PM) is among the most harmful air pollutants to human health, but due to its complex chemical composition is poorly characterized. A large fraction of PM is composed of organic compounds, but these compounds are not regularly monitored due to limitations in current sampling and analysis techniques. The Organic Aerosol Monitor (GC-MS OAM) combines a collection device with thermal desorption, gas chromatography and mass spectrometry to quantitatively measure the carbonaceous components of PM on an hourly averaged basis. The GC-MS OAM is fully automated and has been successfully deployed in the field. It uses a chemically deactivated filter for collection followed by thermal desorption and GC-MS analysis. Laboratory tests show that detection limits range from 0.2 to 3 ng for 16 atmospherically relevant compounds, with the possibility for hundreds more. The GC-MS OAM was deployed in the field for semi-continuous measurement of the organic markers, levoglucosan, dehydroabietic acid, and polycyclic aromatic hydrocarbons (PAHs) from January to March 2015. Results illustrate the significance of this monitoring technique to characterize the organic components of PM and identify sources of pollution.

  16. Host Plant Species Differentiation in a Polyphagous Moth: Olfaction is Enough.

    PubMed

    Conchou, Lucie; Anderson, Peter; Birgersson, Göran

    2017-08-01

    Polyphagous herbivorous insects need to discriminate suitable from unsuitable host plants in complex plant communities. While studies on the olfactory system of monophagous herbivores have revealed close adaptations to their host plant's characteristic volatiles, such adaptive fine-tuning is not possible when a large diversity of plants is suitable. Instead, the available literature on polyphagous herbivore preferences suggests a higher level of plasticity, and a bias towards previously experienced plant species. It is therefore necessary to take into account the diversity of plant odors that polyphagous herbivores encounter in the wild in order to unravel the olfactory basis of their host plant choice behaviour. In this study we show that a polyphagous moth, Spodoptera littoralis, has the sensory ability to distinguish five host plant species using olfaction alone, this being a prerequisite to the ability to make a choice. We have used gas chromatography mass spectrometry (GC-MS) and gas chromatography electroantennographic detection (GC-EAD) in order to describe host plant odor profiles as perceived by S. littoralis. We find that each plant emits specific combinations and proportions of GC-EAD active volatiles, leading to statistically distinct profiles. In addition, at least four of these plants show GC-EAD active compound proportions that are conserved across individual plants, a characteristic that enables insects to act upon previous olfactory experiences during host plant choice. By identifying the volatiles involved in olfactory differentiation of alternative host plants by Spodoptera littoralis, we set the groundwork for deeper investigations of how olfactory perceptions translate into behaviour in polyphagous herbivores.

  17. Supercritical fluid chromatography applied to the highly selective isolation of urinary steroid hormones prior to GC/MS analysis.

    PubMed

    Doué, Mickael; West, Caroline; Bichon, Emmanuelle; Le Bizec, Bruno; Lesellier, Eric

    2018-06-01

    To assess the presence of prohibited anabolic substances used to promote growth in livestock, calf urine is the most relevant matrix. However, the sample preparation methods (required to remove unwanted matrix components and fractionate isobaric species that may be unresolved by gas chromatography- mass spectrometry GC/MS) are long and complex. In this context, semi-preparative supercritical fluid chromatography (SFC) was considered to possibly simplify the sample preparation in reducing the number of procedures. Fifteen stationary phases were screened with SFC combined with UV and evaporative light-scattering detection (ELSD), among which two columns (Cosmosil π-NAP and Princeton DIOL) were retained for their ability to isolate steroid hormones from other matrix components and, for the second column, for the additional possibility to fractionate steroid hormones into different families (estrogens, mono-hydroxylated and di-hydroxylated androgens). The fractions were further analysed with GC/MS showing the benefit of class fractionation. The final method allows for significant time, solvent and money savings compared to the previously widely used method (solid-phase extraction combined with semi-preparative high-performance liquid chromatography). Copyright © 2018 Elsevier B.V. All rights reserved.

  18. GC and GC-MS determination of fluoroacetic acid and phenoxy acid herbicides via triphasal extractive pentafluorobenzylation using a polymer-bound phase-transfer catalyst.

    PubMed

    Miki, A; Tsuchihashi, H; Yamashita, M

    1998-01-01

    A simple and sensitive gas chromatography and gas chromatography-mass spectrometry (GC-MS) procedure has been developed for fluoroacetic acid (FA) and phenoxy acid herbicides (PAHs) via triphasal extractive pentafluorobenzylation. The triphasal system consisted of an aqueous sample, the extraction solvent toluene containing pentafluorobenzyl bromide as the derivatization reagent, and polymer-bound tri-n-butyl-methylphosphonium bromide as a phase-transfer catalyst, FA spiked in beverages, such as orange juice and milk, was extracted as its pentafluorobenzyl (PFB) derivative under moderate conditions (i.e., at a pH value of 6.5 at 60 degrees C). The detection limits were 0.10-0.20 microgram/mL by GC with electron-capture detection (GC-ECD), and 0.42-0.50 microgram/mL by full-scan GC-MS. PAHs were also detectable in the same manner within the detection limits of 0.05-0.10 microgram/mL by GC-ECD and 0.13-0.25 microgram/mL by full-scan GC-MS. Urine and serum which both contained 2,4-dichlorophenoxyacetic acid could also be analyzed by GC-MS after the triphasal pentafluorobenzylation. The detection limit was 0.20 microgram/mL in the full-scan mode and 10 ng/mL in the selected ion monitoring mode both for the urine and serum.

  19. Rapid quantitative detection of glucose content in glucose injection by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-10-20

    This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences <6.45%). The new HS-GC technique is rapid, practical and can be used to the batch detection of the glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    PubMed

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  1. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    PubMed

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  2. Analysis of Endocrine Disrupting Pesticides by Capillary GC with Mass Spectrometric Detection

    PubMed Central

    Matisová, Eva; Hrouzková, Svetlana

    2012-01-01

    Endocrine disrupting chemicals, among them many pesticides, alter the normal functioning of the endocrine system of both wildlife and humans at very low concentration levels. Therefore, the importance of method development for their analysis in food and the environment is increasing. This also covers contributions in the field of ultra-trace analysis of multicomponent mixtures of organic pollutants in complex matrices. With this fact conventional capillary gas chromatography (CGC) and fast CGC with mass spectrometric detection (MS) has acquired a real importance in the analysis of endocrine disrupting pesticide (EDP) residues. This paper provides an overview of GC methods, including sample preparation steps, for analysis of EDPs in a variety of matrices at ultra-trace concentration levels. Emphasis is put on separation method, mode of MS detection and ionization and obtained limits of detection and quantification. Analysis time is one of the most important aspects that should be considered in the choice of analytical methods for routine analysis. Therefore, the benefits of developed fast GC methods are important. PMID:23202677

  3. Validation of a multi-residue method to determine deltamethrin and alpha-cypermethrin in mosquito nets by gas chromatography with electron capture detection (GC-μECD)

    PubMed Central

    2013-01-01

    Background Nowadays long-lasting insecticidal mosquito nets (LNs) are frequently used around the world to protect people against malaria vectors. As they contain insecticide, laboratory control is needed to check whether the content of the active ingredient follows the conditions of the manufacturer and also if the active ingredient is still present after some time of use. For this purpose, an analytical method had to be developed. The fact that LNs include a range of polymers for the yarn and use coated or incorporated technologies for the active ingredient, it is a challenge to find only one analytical method determining the active ingredient in LNs, which takes into account both impregnation technologies. Some methods are provided by international organizations but are limited by the determination of only one pesticide per method. The aim of this study was to optimize a short time extraction method for deltamethrin and alpha-cypermethrin from coated and incorporated mosquito nets and also to detect both insecticides in one analytical run, using gas chromatography with electron capture detection (GC-μECD). Methods Based on the literature, the most suitable solvent and the adequate extraction process for the insecticides used for net making were identified and adapted for the new multi-residue method. Results The validation data of the multi-residue method to determine deltamethrin and alpha-cypermethrin in mosquito nets by GC-μECD are given. Depending on the concentration of the active ingredient spiked on the nets, the mean recovery for alpha-cypermethrin ranged between 86% and 107% with a relative standard deviation below 3.5%. For deltamethrin it ranged between 90% and 108% with a relative standard deviation also below 3.5%. The limit of detection is 0.009 g.a.i/kg of net (0.3 mg a.i./m2 of net) both for alpha-cypermethrin and deltamethrin. Conclusions Data obtained are excellent. A 30 minutes reflux extraction method with xylene was developed to determine

  4. Array of Chemosensitive Resistors with Composites of Gas Chromatography (GC) Materials and Carbon Black for Detection and Recognition of VOCs: A Basic Study

    PubMed Central

    Wyszynski, Bartosz; Yatabe, Rui; Nakao, Atsuo; Nakatani, Masaya; Oki, Akio; Oka, Hiroaki; Toko, Kiyoshi

    2017-01-01

    Mimicking the biological olfaction, large odor-sensor arrays can be used to acquire a broad range of chemical information, with a potentially high degree of redundancy, to allow for enhanced control over the sensitivity and selectivity of artificial olfaction systems. The arrays should consist of the largest possible number of individual sensing elements while being miniaturized. Chemosensitive resistors are one of the sensing platforms that have a potential to satisfy these two conditions. In this work we test viability of fabricating a 16-element chemosensitive resistor array for detection and recognition of volatile organic compounds (VOCs). The sensors were fabricated using blends of carbon black and gas chromatography (GC) stationary-phase materials preselected based on their sorption properties. Blends of the selected GC materials with carbon black particles were subsequently coated over chemosensitive resistor devices and the resulting sensors/arrays evaluated in exposure experiments against vapors of pyrrole, benzenal, nonanal, and 2-phenethylamine at 150, 300, 450, and 900 ppb. Responses of the fabricated 16-element array were stable and differed for each individual odorant sample, proving the blends of GC materials with carbon black particles can be effectively used for fabrication of large odor-sensing arrays based on chemosensitive resistors. The obtained results suggest that the proposed sensing devices could be effective in discriminating odor/vapor samples at the sub-ppm level. PMID:28696353

  5. Comprehensive Urine Drug Screen by Gas Chromatography/Mass Spectrometry (GC/MS).

    PubMed

    Ramoo, Bheemraj; Funke, Melissa; Frazee, Clint; Garg, Uttam

    2016-01-01

    Drug screening is an essential component of clinical toxicology laboratory service. Some laboratories use only automated chemistry analyzers for limited screening of drugs of abuse and few other drugs. Other laboratories use a combination of various techniques such as immunoassays, colorimetric tests, and mass spectrometry to provide more detailed comprehensive drug screening. Mass spectrometry, gas or liquid, can screen for hundreds of drugs and is often considered the gold standard for comprehensive drug screening. We describe an efficient and rapid gas chromatography/mass spectrometry (GC/MS) method for comprehensive drug screening in urine which utilizes a liquid-liquid extraction, sample concentration, and analysis by GC/MS.

  6. Tile-Based Fisher Ratio Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GC × GC – TOFMS) Data using a Null Distribution Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parsons, Brendon A.; Marney, Luke C.; Siegler, William C.

    Multi-dimensional chromatographic instrumentation produces information-rich, and chemically complex data containing meaningful chemical signals and/or chemical patterns. Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a prominent instrumental platform that has been applied extensively for discovery-based experimentation, where samples are sufficiently volatile or amenable to derivatization. Use of GC × GC – TOFMS and associated data analysis strategies aim to uncover meaningful chemical signals or chemical patterns. However, for complex samples, meaningful chemical information is often buried in a background of less meaningful chemical signal and noise. In this report, we utilize the tile-based F-ratiomore » software in concert with the standard addition method by spiking non-native chemicals into a diesel fuel matrix at low concentrations. While the previous work studied the concentration range of 100-1000 ppm, the current study focuses on the 0 ppm to 100 ppm analyte spike range. This study demonstrates the sensitivity and selectivity of the tile-based F-ratio software for discovery of true positives in the non-targeted analysis of a chemically complex and analytically challenging sample matrix. By exploring the low concentration spike levels, we gain a better understanding of the limit of detection (LOD) of the tile-based F-ratio software with GC × GC – TOFMS data.« less

  7. Detection of volatile spoilage metabolites in fermented cucumbers using nontargeted, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS)

    USDA-ARS?s Scientific Manuscript database

    A nontargeted, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GCxGC-TOFMS) method was developed for the analysis of fermented cucumber volatiles before and after anaerobic spoilage. Volatiles extracted by solid-phase microextraction were separated on a polyethyle...

  8. Advanced instrumental methods for analyzing organics in solid waste: The use of gas chromatography/matrix isolation infrared spectroscopy (GC/MIIR) and supercritical fluid chromatography (SFC) for waste characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raphaelian, L.A.; Boparai, A.S.; Schneider, J.F.

    1987-01-01

    Objectives of this research project were: (1) to enhance the capabilities of analyzing the complex mixtures found in coal wastes by using gas chromatography/matrix isolation infrared spectroscopy (GC/MIIR); (2) to separate, by supercritical fluid chromatography (SFC), the complex mixtures found in coal wastes into a few, less-complex mixtures so that analysis by gas chromatography (GC/MS) and GC/MIIR would be simplified. Preliminary results are presented for the mass spectra and infrared spectra of xylene isomers, gas chromatogram of 12 C/sub 2/-Napthalenes, averaged IR spectrum and a comparison of matrix isolation with light-pipe infrared spectra. A SFC chromatogram of polynuclear aromatic hydrocarbonsmore » is also presented. 2 refs., 5 figs.« less

  9. Cuticular hydrocarbons as sex pheromone of the bee Colletes cunicularius and the key to its mimicry by the sexually deceptive orchid, Ophrys exaltata.

    PubMed

    Mant, Jim; Brändli, Christoph; Vereecken, Nicolas J; Schulz, Claudia M; Francke, Wittko; Schiestl, Florian P

    2005-08-01

    Male Colletes cunicularius bees pollinate the orchid, Ophrys exaltata, after being sexually deceived by the orchid's odor-mimicry of the female bee's sex pheromone. We detected biologically active volatiles of C. cunicularius by using gas chromatographic-electroantennographic detection (GC-EAD) with simultaneous flame ionization detection. After identification of the target compounds by coupled gas chromatography mass spectrometry (GC-MS), we performed behavioral tests using synthetic blends of the active components. We detected 22 EAD active compounds in cuticular extracts of C. cunicularius females. Blends of straight chain, odd-numbered alkanes and (Z)-7-alkenes with 21-29 carbon atoms constituted the major biologically active compounds. Alkenes were the key compounds releasing mating behavior, especially those with (Z)-7 unsaturation. Comparison of patterns of bee volatiles with those of O. exaltata subsp. archipelagi revealed that all EAD-active compounds were also found in extracts of orchid labella. Previous studies of the mating behavior in C. cunicularius showed linalool to be an important attractant for patrolling males. We confirmed this with synthetic linalool but found that it rarely elicited copulatory behavior, in accordance with previous studies. A blend of active cuticular compounds with linalool elicited both attraction and copulation behavior in patrolling males. Thus, linalool appears to function as a long-range attractant, whereas cuticular hydrocarbons are necessary for inducing short-range mating behavior.

  10. Response of the small hive beetle (Aethina tumida) to a blend of chemicals identified from honeybee (Apis mellifera) volatiles

    USDA-ARS?s Scientific Manuscript database

    Coupled gas chromatographic-electroantennographic detection (GC-EAD) analyses of Super Q collected worker honey bee volatiles revealed several components that elicited antennal responses by the small hive beetle Aethina tumida. However, GC-MS analysis showed that eight of these EAD-active components...

  11. Comparative analysis of peak-detection techniques for comprehensive two-dimensional chromatography.

    PubMed

    Latha, Indu; Reichenbach, Stephen E; Tao, Qingping

    2011-09-23

    Comprehensive two-dimensional gas chromatography (GC×GC) is a powerful technology for separating complex samples. The typical goal of GC×GC peak detection is to aggregate data points of analyte peaks based on their retention times and intensities. Two techniques commonly used for two-dimensional peak detection are the two-step algorithm and the watershed algorithm. A recent study [4] compared the performance of the two-step and watershed algorithms for GC×GC data with retention-time shifts in the second-column separations. In that analysis, the peak retention-time shifts were corrected while applying the two-step algorithm but the watershed algorithm was applied without shift correction. The results indicated that the watershed algorithm has a higher probability of erroneously splitting a single two-dimensional peak than the two-step approach. This paper reconsiders the analysis by comparing peak-detection performance for resolved peaks after correcting retention-time shifts for both the two-step and watershed algorithms. Simulations with wide-ranging conditions indicate that when shift correction is employed with both algorithms, the watershed algorithm detects resolved peaks with greater accuracy than the two-step method. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    PubMed

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the

  13. A quantification method for peroxyacetyl nitrate (PAN) using gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD)

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Jaffe, Daniel A.; Gao, Xin; McClure, Crystal D.

    2018-04-01

    In this study, we developed a method for continuous PAN measurements by gas chromatography (GC) with a non-radioactive pulsed discharge detector (PDD). Operational parameters were optimized based on the ratio of peak height over baseline noise (P/N ratio). The GC/PDD system was compared with a traditional radioactive electron-capture detector (ECD). In the lab, the method detection limit (MDL) of the new GC/PDD method (9 pptv) was lower than the radioactive GC/ECD method (15 pptv), demonstrating its excellent potential. The MDL of GC/PDD in the field campaign at the Mt. Bachelor Observatory (MBO) was 23 pptv, higher than in the lab. This was caused in part by the decreased slope of the calibration curve resulting from the low air pressure level at MBO. However, the MDL level of GC/PDD at MBO is still low enough for accurate PAN measurements, although special attention should be paid to its application at high-elevation sites. Observations of PAN were conducted at MBO in the summer of 2016 with the GC/PDD system, and provided more evidence of the performance of the system. PAN was found to be highly correlated with CO. The promising performance of GC/PDD which does not require a radioactive source makes it a useful approach for accurate PAN measurements in the field.

  14. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    PubMed

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Carbohydrate profiling of bacteria by gas chromatography-mass spectrometry and their trace detection in complex matrices by gas chromatography-tandem mass spectrometry.

    PubMed

    Fox, A

    1999-05-28

    Bacterial cellular polysaccharides are composed of a variety of sugar monomers. These sugars serve as chemical markers to identify specific species or genera or to determine their physiological status. Some of these markers can also be used for trace detection of bacteria or their constituents in complex clinical or environmental matrices. Analyses are performed, in our hands, employing hydrolysis followed by the alditol acetate derivatization procedure. Substantial improvements have been made to sample preparation including simplification and computer-controlled automation. For characterization of whole cell bacterial hydrolysates, sugars are analyzed by gas chromatography-mass spectrometry (GC-MS). Simple chromatograms are generated using selected ion monitoring (SIM). Using total ion GC-MS, sugars can be readily identified. In more complex clinical and environmental samples, markers for bacteria are present at sufficiently low concentrations that more advanced instrumentation, gas chromatography-tandem mass spectrometry (GC-MS-MS), is preferred for optimal analysis. Using multiple reaction monitoring, MS-MS is used (replacing more conventional SIM) to ignore extraneous chromatographic peaks. Triple quadrupole and ion trap GC-MS-MS instruments have both been used successfully. Absolute chemical identification of sugar markers at trace levels is achieved, using MS-MS, by the product spectrum.

  16. Development of a host-based semiochemical lure for trapping emerald ash borer (Agrilus planipennis (Coleoptera: Buprestidae)

    Treesearch

    Damon J. Crook; Ashot Khrimian; Joseph A. Francese; Ivich Fraser; Therese M. Poland; Alan J. Sawyer; Victor C. Mastro

    2008-01-01

    Bark volatiles from green ash Fraxinus pennsylvanica were tested for electrophysiological activity by Agrilus planipennis using gas chromatographic-electroantennographic detection (GC-EAD) and for behavioral activity using baited purple traps in Michigan. GC-EAD analysis of the headspace volatiles of bark tissue samples from 0...

  17. Preparation of Gc protein-derived macrophage activating factor (GcMAF) and its structural characterization and biological activities.

    PubMed

    Mohamad, Saharuddin Bin; Nagasawa, Hideko; Uto, Yoshihiro; Hori, Hitoshi

    2002-01-01

    Gc protein has been reported to be a precursor of Gc protein-derived macrophage activation factor (GcMAF) in the inflammation-primed macrophage activation cascade. An inducible beta-galactosidase of B cells and neuraminidase of T cells convert Gc protein to GcMAF. Gc protein from human serum was purified using 25(OH)D3 affinity column chromatography and modified to GcMAF using immobilized glycosidases (beta-galactosidase and neuraminidase) The sugar moiety structure of GcMAF was characterized by lectin blotting by Helix pomatia agglutinin. The biological activities of GcMAF were evaluated by a superoxide generation assay and a phagocytosis assay. We successfully purified Gc protein from human serum. GcMAF was detected by lectin blotting and showed a high biological activity. Our results support the importance of the terminal N-acetylgalactosamine moiety in the GcMAF-mediated macrophage activation cascade, and the existence of constitutive GcMAF in human serum. These preliminary data are important for designing small molecular GcMAF mimics.

  18. Identification and field evaluation of fermentation volatiles from wine and vinegar that mediate attraction of spotted wing Drosophila, Drosophila suzukii.

    PubMed

    Cha, Dong H; Adams, Todd; Rogg, Helmuth; Landolt, Peter J

    2012-11-01

    Previous studies suggest that olfactory cues from damaged and fermented fruits play important roles in resource recognition of polyphagous spotted wing Drosophila flies (SWD), Drosophila suzukii (Matsumura) (Diptera: Drosophilidae). They are attracted to fermented sweet materials, such as decomposing fruits but also wines and vinegars, and to ubiquitous fermentation volatiles, such as acetic acid and ethanol. Gas chromatography coupled with electroantennographic detection (GC-EAD), gas chromatography-mass spectrometry (GC-MS), two-choice laboratory bioassays, and field trapping experiments were used to identify volatile compounds from wine and vinegar that are involved in SWD attraction. In addition to acetic acid and ethanol, consistent EAD responses were obtained for 13 volatile wine compounds and seven volatile vinegar compounds, with all of the vinegar EAD-active compounds also present in wine. In a field trapping experiment, the 9-component vinegar blend and 15-component wine blend were similarly attractive when compared to an acetic acid plus ethanol mixture, but were not as attractive as the wine plus vinegar mixture. In two-choice laboratory bioassays, 7 EAD-active compounds (ethyl acetate, ethyl butyrate, ethyl lactate, 1-hexanol, isoamyl acetate, 2-methylbutyl acetate, and ethyl sorbate), when added singly to the mixture at the same concentrations tested in the field, decreased the attraction of SWD to the mixture of acetic acid and ethanol. The blends composed of the remaining EAD-active chemicals, an 8-component wine blend [acetic acid + ethanol + acetoin + grape butyrate + methionol + isoamyl lactate + 2-phenylethanol + diethyl succinate] and a 5-component vinegar blend [acetic acid + ethanol + acetoin + grape butyrate + 2-phenylethanol] were more attractive than the acetic acid plus ethanol mixture, and as attractive as the wine plus vinegar mixture in both laboratory assays and the field trapping experiment. These results indicate that these

  19. CAPILLARY GAS CHROMATOGRAPHY-ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF PENTYLATED ORGANOTIN COMPOUNDS: INTERLABORATORY STUDY

    EPA Science Inventory

    A capillary gas chromatography-atomic emission detection (GC-AED) method was developed for the U. S. Environmental Protection Agency's Environmental Monitoring Systems Laboratory in Las Vegas, NV, for determination of selected organotin compounds. Here we report on an interlabora...

  20. Trace analysis of muramic acid in indoor air using an automated derivatization instrument and GC-MS(2) or GC-MS(3).

    PubMed

    Harley, William M; Kozar, Michael P; Fox, Alvin

    2002-09-01

    An automated derivatization instrument has been developed for the preparation of alditol acetates from bacterial hydrolysates for analysis by gas chromatography-mass spectrometry (GC-MS). The current report demonstrates the utility of the automated instrument for the more demanding task of trace analysis of muramic acid (Mur) in airborne dust using gas chromatography-tandem mass spectrometry (GC-MS(2)). Conditions for efficient derivatization of Mur, vital for trace analysis, are rigorous including lactam and imido group formation under anhydrous conditions. Furthermore, as the detection limit is lowered, possible contamination or carry-over of samples becomes an increasingly greater consideration and must not occur. The instrument meets these criteria and was successfully used for assaying the levels of Mur in laboratory air, which were found to be much lower than in the previous studies of heavily occupied schools and agricultural environments. The potential for GC-MS(3) in further lowering the detection limit was also demonstrated.

  1. Volatilizable Biogenic Organic Compounds (VBOCs) with two dimensional Gas Chromatography-Time of Flight Mass Spectrometry (GC × GC-TOFMS): sampling methods, VBOC complexity, and chromatographic retention data

    NASA Astrophysics Data System (ADS)

    Pankow, J. F.; Luo, W.; Melnychenko, A. N.; Barsanti, K. C.; Isabelle, L. M.; Chen, C.; Guenther, A. B.; Rosenstiel, T. N.

    2012-02-01

    Two dimensional gas chromatography (GC × GC) with detection by time-of-flight mass spectrometry (TOFMS) was applied in the rapid analysis of air samples containing highly complex mixtures of volatilizable biogenic organic compounds (VBOCs). VBOC analytical methodologies are briefly reviewed, and optimal conditions are discussed for sampling with both adsorption/thermal desorption (ATD) cartridges and solid-phase microextraction (SPME) fibers. Air samples containing VBOC emissions from leaves of two tree species (Cedrus atlantica and Calycolpus moritzianus) were obtained by both ATD and SPME. The optimized gas chromatographic conditions utilized a 45 m, 0.25 mm I.D. low-polarity primary column (DB-VRX, 1.4 μm film) and a 1.5 m, 0.25 mm I.D. polar secondary column (StabilwaxTM, 0.25 μm film). Excellent separation was achieved in a 36 min temperature programmed GC × GC chromatogram. Thousands of VBOC peaks were present in the sample chromatograms; hundreds of tentative identifications by NIST mass spectral matching are provided. Very few of the tentatively identified compounds are currently available as authentic standards. Minimum detection limit values for a 5 l ATD sample were 3.5 pptv (10 ng m-3) for isoprene, methyl vinyl ketone, and methacrolein, and ~1.5 pptv (~10 ng m-3) for monoterpenes and sesquiterpenes. Kovats-type chromatographic retention index values on the primary column and relative retention time values on the secondary column are provided for 21 standard compounds and for 417 tentatively identified VBOCs. 19 of the 21 authentic standard compounds were found in one of the Cedrus atlantica SPME samples. In addition, easily quantifiable levels of at least 13 sesquiterpenes were found in an ATD sample obtained from a branch enclosure of Calycolpus moritzianus. Overall, the results obtained via GC × GC-TOFMS highlight an extreme, and largely uncharacterized diversity of VBOCs, consistent with the hypothesis that sesquiterpenes and other compounds

  2. Volatilizable biogenic organic compounds (VBOCs) with two dimensional gas chromatography-time of flight mass spectrometry (GC × GC-TOFMS): sampling methods, VBOC complexity, and chromatographic retention data

    NASA Astrophysics Data System (ADS)

    Pankow, J. F.; Luo, W.; Melnychenko, A. N.; Barsanti, K. C.; Isabelle, L. M.; Chen, C.; Guenther, A. B.; Rosenstiel, T. N.

    2011-06-01

    Two dimensional gas chromatography (GC × GC) with detection by time-of-flight mass spectrometry (TOFMS) was applied in the rapid analysis of air samples containing highly complex mixtures of volatilizable biogenic organic compounds (VBOCs). VBOC analytical methodologies are briefly reviewed, and optimal conditions are discussed for sampling with both adsorption/thermal desorption (ATD) cartridges and solid-phase microextraction (SPME) fibers. Air samples containing VBOC emissions from leaves of two tree species (Cedrus atlantica and Calycolpus moritzianus) were obtained by both ATD and SPME. The optimized gas chromatographic conditions utilized a 45 m, 0.25 mm I.D. low-polarity primary column (DB-VRX, 1.4 μm film) and a 1.5 m, 0.25 mm I.D. polar secondary column (Stabilwax® 0.25 μm film). Excellent separation was achieved in a 36 min temperature programmed GC × GC chromatogram. Thousands of VBOC peaks were present in the sample chromatograms; hundreds of tentative identifications by NIST mass spectral matching are provided. Very few of the tentatively identified compounds are currently available as authentic standards. Method detection limit values for a 5 l ATD sample were 3.5 pptv (10 ng m-3) for isoprene, methyl vinyl ketone, and methacrolein, and ~1.5 pptv (~10 ng m-3) for monoterpenes and sesquiterpenes. Kovats-type chromatographic retention index values on the primary column and relative retention time values on the secondary column are provided for 21 standard compounds and for 417 tentatively identified VBOCs. 19 of the 21 authentic standard compounds were found in one of the Cedrus atlantica SPME samples. In addition, easily quantifiable levels of at least 13 sesquiterpenes were found in an ATD sample obtained from a branch enclosure of Calycolpus moritzianus. Overall, the results obtained via GC × GC-TOFMS highlight an extreme, and largely uncharacterized diversity of VBOCs, consistent with the hypothesis that sesquiterpenes and other compounds

  3. Discrimination of smokeless powders by headspace SPME-GC-MS and SPME-GC-ECD, and the potential implications upon training canine detection of explosives

    NASA Astrophysics Data System (ADS)

    Harper, Ross J.; Almirall, Jose R.; Furton, Kenneth G.

    2005-05-01

    This presentation will provide an odour analysis of a variety of smokeless powders & communicate the rapid SPME-GC-ECD method utilized. This paper will also discuss the implications of the headspace analysis of Smokeless Powders upon the choice of training aids for Explosives Detection Canines. Canine detection of explosives relies upon the dogs" ability to equate finding a given explosive odour with a reward, usually in the form of praise or play. The selection of explosives upon which the dogs are trained thus determines which explosives the canines can and potentially cannot find. Commonly, the training is focussed towards high explosives such as TNT and Composition 4, and the low explosives such as Black and Smokeless Powders are added often only for completeness. Powder explosives constitute a major component of explosive incidents throughout the US, and canines trained to detect explosives must be trained across the entire range of powder products. Given the variability in the manufacture and product make-up many smokeless powders do not share common odour chemicals, giving rise to concerns over the extensiveness of canine training. Headspace analysis of a selection of Smokeless Powders by Solid Phase Microextraction Gas Chromatography using Mass Spectrometry (SPME-GC-MS) and Electron Capture Detectors (SPME-GC-ECD) has highlighted significant differences in the chemical composition of the odour available from different brands. This suggests that greater attention should be paid towards the choice of Powder Explosives when assigning canine training aids.

  4. Male scent-marking pheromone of Bombus ardens ardens (Hymenoptera; Apidae) attracts both conspecific queens and males

    NASA Astrophysics Data System (ADS)

    Kubo, Ryohei; Harano, Ken-ichi; Ono, Masato

    2017-10-01

    To explore the role of the volatiles emitted from male labial gland (LG) of the bumblebee Bombus ardens ardens, we investigated the responses of virgin queens and males to volatiles using a gas chromatography-electroantennographic detector (GC-EAD) system and Y-tube olfactometer. GC-EAD analysis revealed that citronellol, the main compound detected in the male LG, caused clear electrophysiological responses in the antennae of B. a. ardens virgin queens and males although two minor compounds elicited antennal responses when applied in a high concentration. Behavioral tests using a Y-tube olfactometer showed that queens and males were significantly attracted to both LG extracts and citronellol more than to the solvent alone. This is the first study to demonstrate that citronellol as a major compound of male scent-marking pheromone in B. a. ardens functions as a sex attractant for queens. The results also suggest that this compound has another function as a trail marker used by males.

  5. A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    PubMed

    Ishii, A; Seno, H; Suzuki, O; Hattori, H; Kumazawa, T

    1997-01-01

    A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by GC-SID. The calibration curve was linear in the DMT range of 1.25-20 ng/mL blood or urine. The detection limit of DMT was about 0.5 ng/mL (10 pg on-column). The recovery of both DMT and gramine spiked in biological fluids was above 86%.

  6. ISER - Energy Assurance Daily (EAD)

    Science.gov Websites

    can search online for information and the availability of free customizable news alerts, the EAD is section of the OE website. Download the free adobe acrobat reader to view PDFs You will need the Adobe

  7. Tile-based Fisher ratio analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOFMS) data using a null distribution approach.

    PubMed

    Parsons, Brendon A; Marney, Luke C; Siegler, W Christopher; Hoggard, Jamin C; Wright, Bob W; Synovec, Robert E

    2015-04-07

    Comprehensive two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC-TOFMS) is a versatile instrumental platform capable of collecting highly informative, yet highly complex, chemical data for a variety of samples. Fisher-ratio (F-ratio) analysis applied to the supervised comparison of sample classes algorithmically reduces complex GC × GC-TOFMS data sets to find class distinguishing chemical features. F-ratio analysis, using a tile-based algorithm, significantly reduces the adverse effects of chromatographic misalignment and spurious covariance of the detected signal, enhancing the discovery of true positives while simultaneously reducing the likelihood of detecting false positives. Herein, we report a study using tile-based F-ratio analysis whereby four non-native analytes were spiked into diesel fuel at several concentrations ranging from 0 to 100 ppm. Spike level comparisons were performed in two regimes: comparing the spiked samples to the nonspiked fuel matrix and to each other at relative concentration factors of two. Redundant hits were algorithmically removed by refocusing the tiled results onto the original high resolution pixel level data. To objectively limit the tile-based F-ratio results to only features which are statistically likely to be true positives, we developed a combinatorial technique using null class comparisons, called null distribution analysis, by which we determined a statistically defensible F-ratio cutoff for the analysis of the hit list. After applying null distribution analysis, spiked analytes were reliably discovered at ∼1 to ∼10 ppm (∼5 to ∼50 pg using a 200:1 split), depending upon the degree of mass spectral selectivity and 2D chromatographic resolution, with minimal occurrence of false positives. To place the relevance of this work among other methods in this field, results are compared to those for pixel and peak table-based approaches.

  8. Normal-Gamma-Bernoulli Peak Detection for Analysis of Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry Data.

    PubMed

    Kim, Seongho; Jang, Hyejeong; Koo, Imhoi; Lee, Joohyoung; Zhang, Xiang

    2017-01-01

    Compared to other analytical platforms, comprehensive two-dimensional gas chromatography coupled with mass spectrometry (GC×GC-MS) has much increased separation power for analysis of complex samples and thus is increasingly used in metabolomics for biomarker discovery. However, accurate peak detection remains a bottleneck for wide applications of GC×GC-MS. Therefore, the normal-exponential-Bernoulli (NEB) model is generalized by gamma distribution and a new peak detection algorithm using the normal-gamma-Bernoulli (NGB) model is developed. Unlike the NEB model, the NGB model has no closed-form analytical solution, hampering its practical use in peak detection. To circumvent this difficulty, three numerical approaches, which are fast Fourier transform (FFT), the first-order and the second-order delta methods (D1 and D2), are introduced. The applications to simulated data and two real GC×GC-MS data sets show that the NGB-D1 method performs the best in terms of both computational expense and peak detection performance.

  9. Conophthorin enhances the electroantennogram and field behavioral response of Xylosandrus germanus (Coleoptera: Curculionidae) to ethanol

    USDA-ARS?s Scientific Manuscript database

    Ethanol acts as a long range cue that aids Xylosandrus germanus (Blandford) in locating living, but weakened trees. Conophthorin is associated with a variety of deciduous trees and enhances X. germanus’ attraction to vulnerable trees. Electroantennogram (EAG) and field trapping experiments were cond...

  10. Host plant forensics and olfactory-based detection in Afro-tropical mosquito disease vectors.

    PubMed

    Nyasembe, Vincent O; Tchouassi, David P; Pirk, Christian W W; Sole, Catherine L; Torto, Baldwyn

    2018-02-01

    The global spread of vector-borne diseases remains a worrying public health threat, raising the need for development of new combat strategies for vector control. Knowledge of vector ecology can be exploited in this regard, including plant feeding; a critical resource that mosquitoes of both sexes rely on for survival and other metabolic processes. However, the identity of plant species mosquitoes feed on in nature remains largely unknown. By testing the hypothesis about selectivity in plant feeding, we employed a DNA-based approach targeting trnH-psbA and matK genes and identified host plants of field-collected Afro-tropical mosquito vectors of dengue, Rift Valley fever and malaria being among the most important mosquito-borne diseases in East Africa. These included three plant species for Aedes aegypti (dengue), two for both Aedes mcintoshi and Aedes ochraceus (Rift Valley fever) and five for Anopheles gambiae (malaria). Since plant feeding is mediated by olfactory cues, we further sought to identify specific odor signatures that may modulate host plant location. Using coupled gas chromatography (GC)-electroantennographic detection, GC/mass spectrometry and electroantennogram analyses, we identified a total of 21 antennally-active components variably detected by Ae. aegypti, Ae. mcintoshi and An. gambiae from their respective host plants. Whereas Ae. aegypti predominantly detected benzenoids, Ae. mcintoshi detected mainly aldehydes while An. gambiae detected sesquiterpenes and alkenes. Interestingly, the monoterpenes β-myrcene and (E)-β-ocimene were consistently detected by all the mosquito species and present in all the identified host plants, suggesting that they may serve as signature cues in plant location. This study highlights the utility of molecular approaches in identifying specific vector-plant associations, which can be exploited in maximizing control strategies such as such as attractive toxic sugar bait and odor-bait technology.

  11. Host plant forensics and olfactory-based detection in Afro-tropical mosquito disease vectors

    PubMed Central

    Nyasembe, Vincent O.; Tchouassi, David P.; Pirk, Christian W. W.; Sole, Catherine L.

    2018-01-01

    The global spread of vector-borne diseases remains a worrying public health threat, raising the need for development of new combat strategies for vector control. Knowledge of vector ecology can be exploited in this regard, including plant feeding; a critical resource that mosquitoes of both sexes rely on for survival and other metabolic processes. However, the identity of plant species mosquitoes feed on in nature remains largely unknown. By testing the hypothesis about selectivity in plant feeding, we employed a DNA-based approach targeting trnH-psbA and matK genes and identified host plants of field-collected Afro-tropical mosquito vectors of dengue, Rift Valley fever and malaria being among the most important mosquito-borne diseases in East Africa. These included three plant species for Aedes aegypti (dengue), two for both Aedes mcintoshi and Aedes ochraceus (Rift Valley fever) and five for Anopheles gambiae (malaria). Since plant feeding is mediated by olfactory cues, we further sought to identify specific odor signatures that may modulate host plant location. Using coupled gas chromatography (GC)-electroantennographic detection, GC/mass spectrometry and electroantennogram analyses, we identified a total of 21 antennally-active components variably detected by Ae. aegypti, Ae. mcintoshi and An. gambiae from their respective host plants. Whereas Ae. aegypti predominantly detected benzenoids, Ae. mcintoshi detected mainly aldehydes while An. gambiae detected sesquiterpenes and alkenes. Interestingly, the monoterpenes β-myrcene and (E)-β-ocimene were consistently detected by all the mosquito species and present in all the identified host plants, suggesting that they may serve as signature cues in plant location. This study highlights the utility of molecular approaches in identifying specific vector-plant associations, which can be exploited in maximizing control strategies such as such as attractive toxic sugar bait and odor-bait technology. PMID:29462150

  12. The role of electric field in enhancing separation of gas molecules (H2S, CO2, H2O) on VIB modified g-C3N4 (0 0 1)

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Li, Penghui; Wei, Shiqian; Guo, Jiaxing; Dan, Meng; Zhou, Ying

    2018-07-01

    In this study, the first-principles calculations were performed to investigate the adsorption behaviors of gas molecules H2S, CO2 and H2O on Cr, Mo and W modified g-C3N4 (0 0 1) surface. The results show that H2S, CO2 and H2O are physically adsorbed on the pristine g-C3N4, while the adsorption becomes chemisorbed due to the introduction of transition metals which significantly improve the interfacial electron transfer and narrow the band gap of g-C3N4 (0 0 1). Furthermore, it is found that the adsorption behaviors can be greatly influenced by the applied electric field. The adsorption energy is generally arranged in the order of Eads(H2S) > Eads(H2O) > Eads(CO2), and W/g-C3N4 (0 0 1) exhibits the best separation capability. The study could provide a versatile approach to selectively capture and separate the mixed gases in the catalytic reactions by controlling the applied intensity of electric field.

  13. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  14. Coupled liquid chromatography-gas chromatography for the rapid analysis of gamma-oryzanol in rice lipids.

    PubMed

    Miller, Andreas; Frenzel, Thomas; Schmarr, Hans-Georg; Engel, Karl-Heinz

    2003-01-24

    An approach based on on-line coupled liquid chromatography-gas chromatography (LC-GC) was developed for the rapid analysis of gamma-oryzanol in rice. Total lipids were extracted from rice and subjected to LC-GC without any prior purification. gamma-Oryzanol was pre-separated by HPLC from rice lipids and transferred on-line to GC analysis in order to separate its major constituents. 24-methylenecycloartanyl ferulate, cycloartenyl ferulate, campesteryl ferulate, beta-sitosteryl ferulate and campestanyl ferulate. The identities of the compounds were confirmed by off-line GC-MS analysis. Total gamma-oryzanol content could be quantified by HPLC-UV detection and the distribution of gamma-oryzanol constituents could be determined by on-line coupled GC analysis. The proposed methodology paves the way for high-throughput investigations providing information on natural variations in gamma-oryzanol content and its composition in different rice varieties.

  15. Comparison of GC-MS, GC-MRM-MS, and GC × GC to characterise higher plant biomarkers in Tertiary oils and rock extracts

    NASA Astrophysics Data System (ADS)

    Eiserbeck, Christiane; Nelson, Robert K.; Grice, Kliti; Curiale, Joseph; Reddy, Christopher M.

    2012-06-01

    Higher plant biomarkers occur in various compound classes with an array of isomers that are challenging to separate and identify. Traditional one-dimensional (1D) gas chromatographic (GC) techniques achieved impressive results in the past, but have reached limitations in many cases. Comprehensive two-dimensional gas chromatography (GC × GC) either coupled to a flame ionization detector (GC × GC-FID) or time-of-flight mass spectrometer (GC × GC-TOFMS) is a powerful tool to overcome the challenges of 1D GC, such as the resolution of unresolved complex mixture (UCM). We studied a number of Tertiary, terrigenous oils, and source rocks from the Arctic and Southeast Asia, with special focus on angiosperm biomarkers, such as oleanoids and lupanoids. Different chromatographic separation and detection techniques such as traditional 1D GC-MS, metastable reaction monitoring (GC-MRM-MS), GC × GC-FID, and GC × GC-TOFMS are compared and applied to evaluate the differences and advantages in their performance for biomarker identification. The measured 22S/(22S + 22R) homohopane ratios for all applied techniques were determined and compare exceptionally well (generally between 2% and 10%). Furthermore, we resolved a variety of angiosperm-derived compounds that co-eluted using 1D GC techniques, demonstrating the superior separation power of GC × GC for these biomarkers, which indicate terrigenous source input and Cretaceous or younger ages. Samples of varying thermal maturity and biodegradation contain higher plant biomarkers from various stages of diagenesis and catagenesis, which can be directly assessed in a GC × GC chromatogram. The analysis of whole crude oils and rock extracts without loss in resolution enables the separation of unstable compounds that are prone to rearrangement (e.g. unsaturated triterpenoids such as taraxer-14-ene) when exposed to fractionation techniques like molecular sieving. GC × GC-TOFMS is particularly valuable for the successful separation of

  16. Comprehensive two-dimensional gas chromatography with flame ionization and time-of-flight mass spectrometry detection: qualitative and quantitative analysis of West Australian sandalwood oil.

    PubMed

    Shellie, Robert; Marriott, Philip; Morrison, Paul

    2004-09-01

    The use of gas chromatography (GC)-mass spectrometry (MS), GC-time-of-flight MS (TOFMS), comprehensive two-dimensional GC (GCxGC)-flame ionization detection (FID), and GCxGC-TOFMS is discussed for the characterization of the eight important representative components, including Z-alpha-santalol, epi-alpha-bisabolol, Z-alpha-trans-bergamotol, epi-beta-santalol, Z-beta-santalol, E,E-farnesol, Z-nuciferol, and Z-lanceol, in the oil of west Australian sandalwood (Santalum spicatum). Single-column GC-MS lacks the resolving power to separate all of the listed components as pure peaks and allow precise analytical measurement of individual component abundances. With enhanced peak resolution capabilities in GCxGC, these components are sufficiently well resolved to be quantitated using flame ionization detection, following initial characterization of components by using GCxGC-TOFMS.

  17. Characterization of Aronia melanocarpa volatiles by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation/extraction (SDE), and gas chromatography-olfactometry (GC-O) methods.

    PubMed

    Kraujalytė, Vilma; Leitner, Erich; Venskutonis, Petras Rimantas

    2013-05-22

    The profiles of volatile constituents of berry fruit of two Aronia melanocarpa genotypes were evaluated by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation and extraction (SDE), and gas chromatography-olfactometry (GC-O). In total, 74 volatile compounds were identified in chokeberry juice, 3-penten-2-one, 3,9-epoxy-p-menth-1-ene, and benzaldehyde being the most abundant constituents; however, their percentage concentrations were remarkably different in the HS-SPME and SDE profiles. Twenty two aroma-active compounds were detected and characterized by the trained panelists in HS-SPME using GC-O detection frequency analysis. Olfactometry revealed that ethyl-2-methyl butanoate, ethyl-3-methyl butanoate, ethyl decanoate ("fruity" aroma notes), nonanal ("green" notes), unidentified compound possessing "moldy" odor, and some other volatiles may be very important constituents in formation of chokeberry aroma of both analyzed plant cultivars.

  18. Bayesian approach for peak detection in two-dimensional chromatography.

    PubMed

    Vivó-Truyols, Gabriel

    2012-03-20

    A new method for peak detection in two-dimensional chromatography is presented. In a first step, the method starts with a conventional one-dimensional peak detection algorithm to detect modulated peaks. In a second step, a sophisticated algorithm is constructed to decide which of the individual one-dimensional peaks have been originated from the same compound and should then be arranged in a two-dimensional peak. The merging algorithm is based on Bayesian inference. The user sets prior information about certain parameters (e.g., second-dimension retention time variability, first-dimension band broadening, chromatographic noise). On the basis of these priors, the algorithm calculates the probability of myriads of peak arrangements (i.e., ways of merging one-dimensional peaks), finding which of them holds the highest value. Uncertainty in each parameter can be accounted by adapting conveniently its probability distribution function, which in turn may change the final decision of the most probable peak arrangement. It has been demonstrated that the Bayesian approach presented in this paper follows the chromatographers' intuition. The algorithm has been applied and tested with LC × LC and GC × GC data and takes around 1 min to process chromatograms with several thousands of peaks.

  19. Identification of volatiles from pineapple (Ananas comosus L.) pulp by comprehensive two-dimensional gas chromatography and gas chromatography/mass spectrometry.

    PubMed

    Pedroso, Marcio P; Ferreira, Ernesto C; Hantao, Leandro W; Bogusz, Stanislau; Augusto, Fabio

    2011-07-01

    Combining qualitative data from the chromatographic structure of 2-D gas chromatography with flame ionization detection (GC×GC-FID) and that from gas chromatography-mass spectrometry (GC/MS) should result in a more accurate assignment of the peak identities than the simple analysis by GC/MS, where coelution of analytes is unavoidable in highly complex samples (rendering spectra unsuitable for qualitative purposes) or for compounds in very low concentrations. Using data from GC×GC-FID combined with GC/MS can reveal coelutions that were not detected by mass spectra deconvolution software. In addition, some compounds can be identified according to the structure of the GC×GC-FID chromatogram. In this article, the volatile fractions of fresh and dehydrated pineapple pulp were evaluated. The extraction of the volatiles was performed by dynamic headspace extraction coupled to solid-phase microextraction (DHS-SPME), a technique appropriate for slurries or solid matrices. Extracted analytes were then analyzed by GC×GC-FID and GC/MS. The results obtained using both techniques were combined to improve compound identifications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. SIMULTANEOUS DETERMINATION OF ORGANOTIN, ORGANOLEAD, AND ORGANOMERCURY COMPOUNDS IN ENVIRONMENTAL SAMPLES USING CAPILLARY GAS CHROMATOGRAPHY WITH ATOMIC EMISSION DETECTION

    EPA Science Inventory

    As part of a continuing evaluation of new analytical and sample preparation techniques conducted by the US Environmental Protection Agency (EPA), the use of capillary gas chromatography with atomic emission detection (GC-AED) for the simultaneous determination of organotin, organ...

  1. Performance evaluation of the Engineering Analysis and Data Systems (EADS) 2

    NASA Technical Reports Server (NTRS)

    Debrunner, Linda S.

    1994-01-01

    The Engineering Analysis and Data System (EADS)II (1) was installed in March 1993 to provide high performance computing for science and engineering at Marshall Space Flight Center (MSFC). EADS II increased the computing capabilities over the existing EADS facility in the areas of throughput and mass storage. EADS II includes a Vector Processor Compute System (VPCS), a Virtual Memory Compute System (CFS), a Common Output System (COS), as well as Image Processing Station, Mini Super Computers, and Intelligent Workstations. These facilities are interconnected by a sophisticated network system. This work considers only the performance of the VPCS and the CFS. The VPCS is a Cray YMP. The CFS is implemented on an RS 6000 using the UniTree Mass Storage System. To better meet the science and engineering computing requirements, EADS II must be monitored, its performance analyzed, and appropriate modifications for performance improvement made. Implementing this approach requires tool(s) to assist in performance monitoring and analysis. In Spring 1994, PerfStat 2.0 was purchased to meet these needs for the VPCS and the CFS. PerfStat(2) is a set of tools that can be used to analyze both historical and real-time performance data. Its flexible design allows significant user customization. The user identifies what data is collected, how it is classified, and how it is displayed for evaluation. Both graphical and tabular displays are supported. The capability of the PerfStat tool was evaluated, appropriate modifications to EADS II to optimize throughput and enhance productivity were suggested and implemented, and the effects of these modifications on the systems performance were observed. In this paper, the PerfStat tool is described, then its use with EADS II is outlined briefly. Next, the evaluation of the VPCS, as well as the modifications made to the system are described. Finally, conclusions are drawn and recommendations for future worked are outlined.

  2. Identification of unknown impurity of azelaic acid in liposomal formulation assessed by HPLC-ELSD, GC-FID, and GC-MS.

    PubMed

    Han, Stanisław; Karłowicz-Bodalska, Katarzyna; Potaczek, Piotr; Wójcik, Adam; Ozimek, Lukasz; Szura, Dorota; Musiał, Witold

    2014-02-01

    The identification of new contaminants is critical in the development of new medicinal products. Many impurities, such as pentanedioic acid, hexanedioic acid, heptanedioic acid, octanedioic acid, decanedioic acid, undecanedioic acid, dodecanedioic acid, tridecanedioic acid, and tetradecanedioic acid, have been identified in samples of azelaic acid. The aim of this study was to identify impurities observed during the stability tests of a new liposomal dosage form of azelaic acid that is composed of phosphatidylcholine and a mixture of ethyl alcohol and water, using high-performance liquid chromatography with evaporative light-scattering detector (HPLC-ELSD), gas chromatography-flame ionisation detection (GC-FID), and gas chromatography-mass spectrometry (GC-MS) methods. During the research and development of a new liposomal formulation of azelaic acid, we developed a method for determining the contamination of azelaic acid using HPLC-ELSD. During our analytical tests, we identified a previously unknown impurity of a liposomal preparation of azelaic acid that appeared in the liposomal formulation of azelaic acid during preliminary stability studies. The procedure led to the conclusion that the impurity was caused by the reaction of azelaic acid with one of the excipients that was applied in the product. The impurity was finally identified as an ethyl monoester of azelaic acid. The identification procedure of this compound was carried out in a series of experiments comparing the chromatograms that were obtained via the following chromatographic methods: HPLC-ELSD, GC-FID, and GC-MS. The final identification of the compound was carried out by GC with MS.

  3. Microwave assisted saponification (MAS) followed by on-line liquid chromatography (LC)-gas chromatography (GC) for high-throughput and high-sensitivity determination of mineral oil in different cereal-based foodstuffs.

    PubMed

    Moret, Sabrina; Scolaro, Marianna; Barp, Laura; Purcaro, Giorgia; Conte, Lanfranco S

    2016-04-01

    A high throughput, high-sensitivity procedure, involving simultaneous microwave-assisted extraction (MAS) and unsaponifiable extraction, followed by on-line liquid chromatography (LC)-gas chromatography (GC), has been optimised for rapid and efficient extraction and analytical determination of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH) in cereal-based products of different composition. MAS has the advantage of eliminating fat before LC-GC analysis, allowing an increase in the amount of sample extract injected, and hence in sensitivity. The proposed method gave practically quantitative recoveries and good repeatability. Among the different cereal-based products analysed (dry semolina and egg pasta, bread, biscuits, and cakes), egg pasta packed in direct contact with recycled paperboard had on average the highest total MOSH level (15.9 mg kg(-1)), followed by cakes (10.4 mg kg(-1)) and bread (7.5 mg kg(-1)). About 50% of the pasta and bread samples and 20% of the biscuits and cake samples had detectable MOAH amounts. The highest concentrations were found in an egg pasta in direct contact with recycled paperboard (3.6 mg kg(-1)) and in a milk bread (3.6 mg kg(-1)). Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Chemotaxonomic differentiation of legionellae by detection and characterization of aminodideoxyhexoses and other unique sugars using gas chromatography-mass spectrometry.

    PubMed Central

    Fox, A; Rogers, J C; Fox, K F; Schnitzer, G; Morgan, S L; Brown, A; Aono, R

    1990-01-01

    Legionellae have been differentiated previously by analyzing their carbohydrate contents by gas chromatography with flame ionization detection. In the present study, total ion mode gas chromatography-mass spectrometry (GC-MS) was used to detect a number of unusual sugars, including one that is structurally related to O-methyldideoxyheptoses. Increased sensitivity and selectivity for carbohydrate detection was achieved by selected ion-monitoring GC-MS. Two of the uncommon sugars previously discovered in the legionellae (X1 and X2) were identified as quinovosamine and fucosamine, respectively. Legionella pneumophila contained rhamnose and quinovosamine but not the quinovosamine isomer fucosamine. Tatlockia micdadei and Legionella maceachernii contained large amounts of rhamnose, fucose, and fucosamine but not quinovosamine. These two species were the only legionellae studied that contained another unusual sugar that is referred to as X3, pending determination of its structure. Fluoribacter dumoffi, Fluoribacter bozemanae, and Legionella anisa were varied in their carbohydrate contents, both within and between species, but could be distinguished from L. pneumophila and the T. micdadei and L. maceachernii group. Fluoribacter gormanii was unique among the legionellae in that it lacked both quinovosamine and fucosamine. Legionella jordanis contained other unusual carbohydrates in addition to quinovosamine. GC-MS may have wide application in the differentiation of bacterial species. PMID:2324276

  5. Considerations on the determination of the limit of detection and the limit of quantification in one-dimensional and comprehensive two-dimensional gas chromatography.

    PubMed

    Krupčík, Ján; Májek, Pavel; Gorovenko, Roman; Blaško, Jaroslav; Kubinec, Robert; Sandra, Pat

    2015-05-29

    Methods based on the blank signal as proposed by IUPAC procedure and on the signal to noise ratio (S/N) as listed in the ISO-11843-1 norm for determination of the limit of detection (LOD) and quantitation (LOQ) in one-dimensional capillary gas chromatography (1D-GC) and comprehensive two-dimensional capillary gas chromatography (CG×GC) are described in detail and compared for both techniques. Flame ionization detection was applied and variables were the data acquisition frequency and, for CG×GC, also the modulation time. It has been stated that LOD and LOQ estimated according to IUPAC might be successfully used for 1D-GC-FID method. Moreover, LOD and LOQ decrease with decrease of data acquisition frequency (DAF). For GC×GC-FID, estimation of LOD by IUPAC gave poor reproducibility of results while for LOQ reproducibility was acceptable (within ±10% rel.). The LOD and LOQ determined by the S/N concept both for 1D-GC-FID and GC×GC-FID methods are ca. three times higher than those values estimated by the standard deviation of the blank. Since the distribution pattern of modulated peaks for any analyte separated by GC×GC is random and cannot be predicted, LOQ and LOD may vary within 30% for 3s modulation time. Concerning sensitivity, 1D-GC-FID at 2Hz and of GC×GC-FID at 50Hz shows a ca. 5 times enhancement of sensitivity in the modulated signal output. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Organophosphorus pesticide and ester analysis by using comprehensive two-dimensional gas chromatography with flame photometric detection.

    PubMed

    Liu, Xiangping; Li, Dengkun; Li, Jiequan; Rose, Gavin; Marriott, Philip J

    2013-12-15

    Thirty-seven phosphorus (P)-containing compounds comprising organophosphorus pesticides and organophosphate esters were analyzed by using comprehensive two-dimensional gas chromatography with flame photometric detection in P mode (GC × GC-FPD(P)), with a non-polar/moderately polar column set. A suitable modulation temperature and period was chosen based on experimental observation. A number of co-eluting peak pairs on the (1)D column were well separated in 2D space. Excellent FPD(P) detection selectivity, responding to compounds containing the P atom, produces clear 2D GC × GC plots with little interference from complex hydrocarbon matrices. Limits of detection (LOD) were within the range of 0.0021-0.048 μmol L(-1), and linear calibration correlation coefficients (R(2)) for all 37 P-compounds were at least 0.998. The P-compounds were spiked in 2% diesel and good reproducibility for their response areas and retention times was obtained. Spiked recoveries were 88%-157% for 5 μg L(-1) and 80%-138% for 10 μg L(-1) spiked levels. Both (1)tR and (2)tR shifts were noted when the content of diesel was in excess of 5% in the matrix. Soil samples were analyzed by using the developed method; some P-compounds were positively detected. In general, this study shows that GC × GC-FPD(P) is an accurate, sensitive and simple method for P-compound analysis in complicated environmental samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Coupling gas chromatography and electronic nose detection for detailed cigarette smoke aroma characterization.

    PubMed

    Rambla-Alegre, Maria; Tienpont, Bart; Mitsui, Kazuhisa; Masugi, Eri; Yoshimura, Yuta; Nagata, Hisanori; David, Frank; Sandra, Pat

    2014-10-24

    Aroma characterization of whole cigarette smoke samples using sensory panels or electronic nose (E-nose) devices is difficult due to the masking effect of major constituents and solvent used for the extraction step. On the other hand, GC in combination with olfactometry detection does not allow to study the delicate balance and synergetic effect of aroma solutes. To overcome these limitations a new instrumental set-up consisting of heart-cutting gas chromatography using a capillary flow technology based Deans switch and low thermal mass GC in combination with an electronic nose device is presented as an alternative to GC-olfactometry. This new hyphenated GC-E-nose configuration is used for the characterization of cigarette smoke aroma. The system allows the transfer, combination or omission of selected GC fractions before injection in the E-nose. Principal component analysis (PCA) and discriminant factor analysis (DFA) allowed clear visualizing of the differences among cigarette brands and classifying them independently of their nicotine content. Omission and perceptual interaction tests could also be carried out using this configuration. The results are promising and suggest that the GC-E-nose hyphenation is a good approach to measure the contribution level of individual compounds to the whole cigarette smoke. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Improved electroacoustic dewatering (EAD) belt press for food products. Phase 3, Technical progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-02-01

    Battelle`s electroacoustic dewatering (EAD) process improves the performance of mechanical dewatering processes for several food products (such as corn fiber) by superimposing electric and ultrasonic fields. EAD has the potential to save 0.027 to 0.035 quad/yr energy by 1995 in the food processing industry, which consumed 0.15 to 0.18 quad in 1986. This report covers Phase III for demonstrating the EAD prototype on corn wet milling products (corn fiber and gluten); only Task 1 (prototype preparation and planning) was completed. EAD performance was examined in the laboratory; availability of a test site was examined. The single-roll, postdewatering EAD belt pressmore » prototype can accept material predewatered by a screw press, centrifuge, or any other mechanical dewatering device. The two-belt system, utilizing a copper-polymer cathode belt, performed as well as the three-belt system used in Phase II.« less

  9. Characterization of E 471 food emulsifiers by high-performance thin-layer chromatography-fluorescence detection.

    PubMed

    Oellig, Claudia; Brändle, Klara; Schwack, Wolfgang

    2018-07-13

    Mono- and diacylglycerol (MAG and DAG) emulsifiers, also known as food additive E 471, are widely used to adjust techno-functional properties in various foods. Besides MAGs and DAGs, E 471 emulsifiers additionally comprise different amounts of triacylglycerols (TAGs) and free fatty acids (FFAs). MAGs, DAGs, TAGs and FFAs are generally determined by high-performance liquid chromatography (HPLC) or gas chromatography (GC) coupled to mass selective detection, analyzing the individual representatives of the lipid classes. In this work we present a rapid and sensitive method for the determination of MAGs, DAGs, TAGs and FFAs in E 471 emulsifiers by high-performance thin-layer chromatography with fluorescence detection (HPTLC-FLD), including a response factor system for quantitation. Samples were simply dissolved and diluted with t-butyl methyl ether before a two-fold development was performed on primuline pre-impregnated LiChrospher silica gel plates with diethyl ether and n-pentane/n-hexane/diethyl ether (52:20:28, v/v/v) as the mobile phases to 18 and 75 mm, respectively. For quantitation, the plate was scanned in the fluorescence mode at UV 366/>400 nm, when the cumulative signal for each lipid class was used. Calibration was done with 1,2-distearin and amounts of lipid classes were calculated with response factors and expressed as monostearin, distearin, tristearin and stearic acid. Limits of detection and quantitation were 1 and 4 ng/zone, respectively, for 1,2-distearin. Thus, the HPTLC-FLD approach represents a simple, rapid and convenient screening alternative to HPLC and GC analysis of the individual compounds. Visual detection additionally enables an easy characterization and the direct comparison of emulsifiers through the lipid class pattern, when utilized as a fingerprint. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Qualitative and quantitative analysis of pyrolysis oil by gas chromatography with flame ionization detection and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry.

    PubMed

    Sfetsas, Themistoklis; Michailof, Chrysa; Lappas, Angelos; Li, Qiangyi; Kneale, Brian

    2011-05-27

    Pyrolysis oils have attracted a lot of interest, as they are liquid energy carriers and general sources of chemicals. In this work, gas chromatography with flame ionization detector (GC-FID) and two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) techniques were used to provide both qualitative and quantitative results of the analysis of three different pyrolysis oils. The chromatographic methods and parameters were optimized and solvent choice and separation restrictions are discussed. Pyrolysis oil samples were diluted in suitable organic solvent and were analyzed by GC×GC-TOFMS. An average of 300 compounds were detected and identified in all three samples using the ChromaToF (Leco) software. The deconvoluted spectra were compared with the NIST software library for correct matching. Group type classification was performed by use of the ChromaToF software. The quantification of 11 selected compounds was performed by means of a multiple-point external calibration curve. Afterwards, the pyrolysis oils were extracted with water, and the aqueous phase was analyzed both by GC-FID and, after proper change of solvent, by GC×GC-TOFMS. As previously, the selected compounds were quantified by both techniques, by means of multiple point external calibration curves. The parameters of the calibration curves were calculated by weighted linear regression analysis. The limit of detection, limit of quantitation and linearity range for each standard compound with each method are presented. The potency of GC×GC-TOFMS for an efficient mapping of the pyrolysis oil is undisputable, and the possibility of using it for quantification as well has been demonstrated. On the other hand, the GC-FID analysis provides reliable results that allow for a rapid screening of the pyrolysis oil. To the best of our knowledge, very few papers have been reported with quantification attempts on pyrolysis oil samples using GC×GC-TOFMS most of which make use of the

  11. Evaluation of Gas Chromatography/Mini-IMS to Detect VOCs

    NASA Technical Reports Server (NTRS)

    Limero, Thomas; Reese, Eric; Peters, Randy; James, John T.; Billica, Roger (Technical Monitor)

    1999-01-01

    The Toxicology Laboratory at Johnson Space Center (JSC) has pioneered the use of gas chromatography-ion mobility spectrometry (GC/IMS) for measuring target volatile organic compounds (VOCs) aboard spacecraft. Graseby Dynamics, under contract to NASA/Wyle, has built several volatile organic analyzers (VOA) based on GC/IMS. Foremost among these have been the volatile organic analyzer-risk mitigation unit and the two flight VOA units for International Space Station (ISS). The development and evaluation of these instruments has been chronicled through presentations at the International Conference on Ion Mobility Spectrometry over the past three years. As the flight VOA from Graseby is prepared for operation on ISS at JSC, it is time to begin evaluations of technologies for the next generation VOA, Although the desired instrument characteristics for the next generation unit are the same as the current unit, the requirements are much more stringent. As NASA looks toward future missions beyond Earth environs, a premium will be placed upon small, light, reliable, autonomous hardware. It is with these visions in mind that the JSC Toxicology Laboratory began a search for the next generation VOA. One technology that is a candidate for the next generation VOA is GC/IMS. The recent miniaturization of IMS technology permits it to compete with other, inherently small, technologies such as chip-sized sensor arrays. This paper will discuss the lessons learned from the VOA experience and how that has shaped the design of a potential second generation VOA based upon GC/IMS technology. Data will be presented from preliminary evaluations of GC technology and the mini-IMS when exposed to VOCs likely to be detected aboard spacecraft. Results from the evaluation of an integrated GC/mini-IMS system will be shown if available.

  12. Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.

    PubMed

    Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H

    2000-05-01

    Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.

  13. Derivatization of organophosphorus nerve agent degradation products for gas chromatography with ICPMS and TOF-MS detection.

    PubMed

    Richardson, Douglas D; Caruso, Joseph A

    2007-06-01

    Separation and detection of seven V-type (venomous) and G-type (German) organophosphorus nerve agent degradation products by gas chromatography with inductively coupled plasma mass spectrometry (GC-ICPMS) is described. The nonvolatile alkyl phosphonic acid degradation products of interest included ethyl methylphosphonic acid (EMPA, VX acid), isopropyl methylphosphonic acid (IMPA, GB acid), ethyl hydrogen dimethylamidophosphate sodium salt (EDPA, GA acid), isobutyl hydrogen methylphosphonate (IBMPA, RVX acid), as well as pinacolyl methylphosphonic acid (PMPA), methylphosphonic acid (MPA), and cyclohexyl methylphosphonic acid (CMPA, GF acid). N-(tert-Butyldimethylsilyl)-N-methyltrifluroacetamide with 1% TBDMSCl was utilized to form the volatile TBDMS derivatives of the nerve agent degradation products for separation by GC. Exact mass confirmation of the formation of six of the TBDMS derivatives was obtained by GC-time of flight mass spectrometry (TOF-MS). The method developed here allowed for the separation and detection of all seven TBDMS derivatives as well as phosphate in less than ten minutes. Detection limits for the developed method were less than 5 pg with retention times and peak area precisions of less than 0.01 and 6%, respectively. This method was successfully applied to river water and soil matrices. To date this is the first work describing the analysis of chemical warfare agent (CWA) degradation products by GC-ICPMS.

  14. Characterization of the Key Aroma Volatile Compounds in Cranberry (Vaccinium macrocarpon Ait.) Using Gas Chromatography-Olfactometry (GC-O) and Odor Activity Value (OAV).

    PubMed

    Zhu, JianCai; Chen, Feng; Wang, LingYing; Niu, YunWei; Chen, HeXing; Wang, HongLin; Xiao, ZuoBing

    2016-06-22

    The volatile compounds of cranberries obtained from four cultivars (Early Black, Y1; Howes, Y2; Searles, Y3; and McFarlin, Y4) were analyzed by gas chromatography-olfactometry (GC-O), gas chromatography-mass spectrometry (GC-MS), and GC-flame photometric detection (FPD). The result presented that a total of thirty-three, thirty-four, thirty-four, and thirty-six odor-active compounds were identified by GC-O in the Y1, Y2, Y3, and Y4, respectively. In addition, twenty-two, twenty-two, thirty, and twenty-seven quantified compounds were demonstrated as important odorants according to odor activity values (OAVs > 1). Among these compounds, hexanal (OAV: 27-60), pentanal (OAV: 31-51), (E)-2-heptenal (OAV: 17-66), (E)-2-hexenal (OAV: 18-63), (E)-2-octenal (OAV: 10-28), (E)-2-nonenal (OAV: 8-77), ethyl 2-methylbutyrate (OAV: 10-33), β-ionone (OAV: 8-73), 2-methylbutyric acid (OAV: 18-37), and octanal (OAV: 4-24) contributed greatly to the aroma of cranberry. Partial least-squares regression (PLSR) was used to process the mean data accumulated from sensory evaluation by the panelists, odor-active aroma compounds (OAVs > 1), and samples. Sample Y3 was highly correlated with the sensory descriptors "floral" and "fruity". Sample Y4 was greatly related to the sensory descriptors "mellow" and "green and grass". Finally, an aroma reconstitution (Model A) was prepared by mixing the odor-active aroma compounds (OAVs > 1) based on their measured concentrations in the Y1 sample, indicating that the aroma profile of the reconstitution was pretty similar to that of the original sample.

  15. Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

    NASA Technical Reports Server (NTRS)

    Holland, P.; Chutjian, A.; Darrach, M.; Orient, O.

    2002-01-01

    Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

  16. Determination of phenobarbital in hair matrix by liquid phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Roveri, Flávia Lopes; Paranhos, Beatriz Aparecida Passos Bismara; Yonamine, Mauricio

    2016-08-01

    A method for identification and quantification of phenobarbital in hair samples by liquid phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS) has been presented. Drug-free hair specimens were collected and separated in 50mg aliquots. Each aliquot was washed with 2.0mL of dichloromethane for 15min at 37°C. Standards and deuterated internal standards for calibration and quality control samples were added to the washed hair aliquot and the sample was submitted to complete digestion with sodium hydroxide (NaOH) 1.0mol/L for 15min at 70°C. The dissolved sample was submitted to LPME. After extraction, the residue was derivatized with tetramethylammonium hydroxide (TMAH) and analyzed by GC-MS. The limit of detection (LOD) was 0.1ng/mg and the limit of quantification (LOQ) was 0.25ng/mg. The calibration curve was linear over a concentration range of 0.25ng/mg to 10ng/mg (r(2)>0.99). The intra- and inter-assay precisions, given by RSD, were less than 6% for phenobarbital. Fortified samples of secobarbital and pentobarbital were also submitted to the validated method. The method was successfully applied to hair samples collected from three volunteers who reported regular use of phenobarbital (clinical treatment). The concentrations found were 9.5, 15.1 and 16.3ng/mg of phenobarbital. To contemplate the concentrations found, dilution integrity tests were also validated. The LPME and GC-MS method showed to be suitable for the detection of phenobarbital in hair samples and can be promptly used for different purposes whenever required. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data.

    PubMed

    Tian, Tze-Feng; Wang, San-Yuan; Kuo, Tien-Chueh; Tan, Cheng-En; Chen, Guan-Yuan; Kuo, Ching-Hua; Chen, Chi-Hsin Sally; Chan, Chang-Chuan; Lin, Olivia A; Tseng, Y Jane

    2016-11-01

    Two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) is superior for chromatographic separation and provides great sensitivity for complex biological fluid analysis in metabolomics. However, GC×GC/TOF-MS data processing is currently limited to vendor software and typically requires several preprocessing steps. In this work, we implement a web-based platform, which we call GC 2 MS, to facilitate the application of recent advances in GC×GC/TOF-MS, especially for metabolomics studies. The core processing workflow of GC 2 MS consists of blob/peak detection, baseline correction, and blob alignment. GC 2 MS treats GC×GC/TOF-MS data as pictures and clusters the pixels as blobs according to the brightness of each pixel to generate a blob table. GC 2 MS then aligns the blobs of two GC×GC/TOF-MS data sets according to their distance and similarity. The blob distance and similarity are the Euclidean distance of the first and second retention times of two blobs and the Pearson's correlation coefficient of the two mass spectra, respectively. GC 2 MS also directly corrects the raw data baseline. The analytical performance of GC 2 MS was evaluated using GC×GC/TOF-MS data sets of Angelica sinensis compounds acquired under different experimental conditions and of human plasma samples. The results show that GC 2 MS is an easy-to-use tool for detecting peaks and correcting baselines, and GC 2 MS is able to align GC×GC/TOF-MS data sets acquired under different experimental conditions. GC 2 MS is freely accessible at http://gc2ms.web.cmdm.tw .

  18. Extraction of pure components from overlapped signals in gas chromatography-mass spectrometry (GC-MS)

    PubMed Central

    Likić, Vladimir A

    2009-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a widely used analytical technique for the identification and quantification of trace chemicals in complex mixtures. When complex samples are analyzed by GC-MS it is common to observe co-elution of two or more components, resulting in an overlap of signal peaks observed in the total ion chromatogram. In such situations manual signal analysis is often the most reliable means for the extraction of pure component signals; however, a systematic manual analysis over a number of samples is both tedious and prone to error. In the past 30 years a number of computational approaches were proposed to assist in the process of the extraction of pure signals from co-eluting GC-MS components. This includes empirical methods, comparison with library spectra, eigenvalue analysis, regression and others. However, to date no approach has been recognized as best, nor accepted as standard. This situation hampers general GC-MS capabilities, and in particular has implications for the development of robust, high-throughput GC-MS analytical protocols required in metabolic profiling and biomarker discovery. Here we first discuss the nature of GC-MS data, and then review some of the approaches proposed for the extraction of pure signals from co-eluting components. We summarize and classify different approaches to this problem, and examine why so many approaches proposed in the past have failed to live up to their full promise. Finally, we give some thoughts on the future developments in this field, and suggest that the progress in general computing capabilities attained in the past two decades has opened new horizons for tackling this important problem. PMID:19818154

  19. Simultaneous Detection of Androgen and Estrogen Abuse in Breeding Animals by Gas Chromatography-Mass Spectrometry/Combustion/Isotope Ratio Mass Spectrometry (GC-MS/C/IRMS) Evaluated against Alternative Methods.

    PubMed

    Janssens, Geert; Mangelinckx, Sven; Courtheyn, Dirk; De Kimpe, Norbert; Matthijs, Bert; Le Bizec, Bruno

    2015-09-02

    The administration of synthetic homologues of naturally occurring steroids can be demonstrated by measuring (13)C/(12)C isotopic ratios of their urinary metabolites. Gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry (GC-MS/C/IRMS) was used in this study to appraise in a global approach isotopic deviations of two 17β-testosterone metabolites (17α-testosterone and etiocholanolone) and one 17β-estradiol metabolite (17α-estradiol) together with those of 5-androstene-3β,17α-diol as endogenous reference compound (ERC). Intermediate precisions of 0.35‰, 1.05‰, 0.35‰, and 0.21‰, respectively, were observed (n = 8). To assess the performance of the analytical method, a bull and a heifer were treated with 17β-testosterone propionate and 17β-estradiol-3-benzoate. The sensitivity of the method permitted the demonstration of 17β-estradiol treatment up to 24 days. For 17β-testosterone treatment, the detection windows were 3 days and 24 days for the bull and the heifer, respectively. The capability of GC-MS/C/IRMS to demonstrate natural steroid abuse for urinary steroids was eventually compared to those of mass spectrometry (LC-MS/MS) when measuring intact steroid esters in blood and hair.

  20. Simultaneous detection of seventeen drugs of abuse and metabolites in hair using solid phase micro extraction (SPME) with GC/MS.

    PubMed

    Aleksa, Katarina; Walasek, Paula; Fulga, Netta; Kapur, Bhushan; Gareri, Joey; Koren, Gideon

    2012-05-10

    The analysis of pediatric and adult hair is a useful non-invasive biomarker to effectively detect long term exposure to various xenobiotics, specifically drugs of abuse such as cocaine, opiates and amphetamines. Very often individuals are using, or are exposed to multiple drugs simultaneously and therefore it is important to be able to detect them in the same analysis. We have developed a sensitive and specific solid phase micro extraction (SPME) coupled with gas chromatography mass spectrometry (GC/MS) to detect 17 different analytes in hair using a single extraction method. Five milligrams of hair is extracted overnight, subjected to solid phase extraction (SPE) and then to SPME-GC/MS. The aimed analytes include amphetamine, methamphetamine, MDA, MDMA, cocaine, benzoylecognine, norcocaine, cocaethylene, methadone, codeine, morphine, 6-AM, oxycodone, oxymorphone, hydrocodone, hydromorphone and meperidone. The following are the LOD of the various drugs: 0.2ng/mg hair for amphetamine, methamphetamine, MDA, MDMA, morphine, codeine, 6-AM, oxycodone, oxymorphone, hydromorphone, hydrocodone, meperidine and 0.13ng/mg hair for cocaine, benzoylecognine, cocaethylene, norcocaine and methadone. This GC/MS method is sensitive and specific to detect the presence of these 17 analytes in as little as 5mg of hair and is especially useful for newborn and child hair analysis where the amount of hair is often very limited. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were < 6% and < 13%, respectively. This procedure has been applied to quality-control specimens and LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  2. 78 FR 76050 - Airworthiness Directives; EADS CASA (Type Certificate Previously Held by Construcciones...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... Airworthiness Directives; EADS CASA (Type Certificate Previously Held by Construcciones Aeron[aacute]uticas, S.A... Certificate Previously Held by Construcciones Aeron[aacute]uticas, S.A.) Model C-212-CB, C-212-CC, C-212-CD, C... changed paragraph (c) of this AD to remove EADS CASA (Type Certificate previously held by Construcciones...

  3. Valid internal standard technique for arson detection based on gas chromatography-mass spectrometry.

    PubMed

    Salgueiro, Pedro A S; Borges, Carlos M F; Bettencourt da Silva, Ricardo J N

    2012-09-28

    The most popular procedures for the detection of residues of accelerants in fire debris are the ones published by the American Society for Testing and Materials (ASTM E1412-07 and E1618-10). The most critical stages of these tests are the conservation of fire debris from the sampling to the laboratory, the extraction of residues of accelerants from the debris to the activated charcoal strips (ACS) and from those to the final solvent, as well as the analysis of sample extract by gas chromatography-mass spectrometry (GC-MS) and the interpretation of the instrumental signal. This work proposes a strategy for checking the quality of the sample conservation, the accelerant residues transference to final solvent and GC-MS analysis, using internal standard additions. It is used internal standards ranging from a highly volatile compound for checking debris conservation to low volatile compound for checking GC-MS repeatability. The developed quality control (QC) parameters are not affected by GC-MS sensitivity variation and, specifically, the GC-MS performance control is not affected by ACS adsorption saturation that may mask test performance deviations. The proposed QC procedure proved to be adequate to check GC-MS repeatability, ACS extraction and sample conservation since: (1) standard additions are affected by negligible uncertainty and (2) observed dispersion of QC parameters are fit for its intended use. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Detailed study of polystyrene solubility using pyrolysis-gas chromatography-mass spectrometry and combination with size-exclusion chromatography.

    PubMed

    Chojnacka, Aleksandra; Janssen, Hans-Gerd; Schoenmakers, Peter

    2014-01-01

    Measuring polymer solubility accurately and precisely is challenging. This is especially true at unfavourable solvent compositions, when only very small amounts of polymer dissolve. In this paper, pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) is demonstrated to be much more informative and sensitive than conventional methods, such as ultraviolet spectroscopy. By using a programmed-temperature-vapourisation injector as the pyrolysis chamber, we demonstrate that Py-GC-MS can cover up to five orders of magnitude in dissolved polymer concentrations. For polystyrene, a detection limit of 1 ng mL(-1) is attained. Dissolution in poor solvents is demonstrated to be discriminating in terms of the analyte molecular weight. Py-GC-MS additionally can yield information on polymer composition (e.g. in case of copolymers). In combination with size-exclusion chromatography, Py-GC-MS allows us to estimate the molecular weight distributions of minute amounts of a dissolved polymer and variations therein as a function of time.

  5. Evaluation of comprehensive two-dimensional gas chromatography with flame photometric detection: potential application for sulfur speciation in shale oil.

    PubMed

    Mitrevski, Blagoj; Amer, Mohammad W; Chaffee, Alan L; Marriott, Philip J

    2013-11-25

    Flame photometric detection in the sulfur channel has been evaluated for sulfur speciation and quantification in comprehensive two-dimensional gas chromatography [GC × GC-FPD(S)] for S-compound speciation in shale extracts. Signal non-linearity and potential quenching effects were reportedly major limitations of this detector for analysis of sulfur in complex matrices. However, reliable linear relationships with correlation coefficient >0.99 can be obtained if the sum of the square root of each modulation slice in GC × GC is plotted vs. sulfur concentration. Furthermore, the quenching effects are reduced due to essentially complete separation of S-containing components from the hydrocarbon matrix. An increase of S/N of up to 150 times has been recorded for benzothiophene and dibenzothiophene in GC × GC-FPD when compared to GC-FPD due to the modulation process. As a consequence, 10 times lower detection limits were observed in the former mode. The applicability of the method was demonstrated using shale oil sample extracts. Three sulfur classes were completely separated and the target class (thiophenes) was successfully quantified after the rest of the sample was diverted to the second detector by using a heart-cut strategy. Based on the proposed method, 70% of the sulfur in the shale oil was assigned to the thiophenes, 24% to benzothiophenes, and 5% to dibenzothiophene compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Determination of benazolin-ethyl residues in soil and rape seed by SPE clean-up and GC with electron capture detection.

    PubMed

    Liu, Xiaolu; Yang, Tao; Hu, Jiye

    2013-01-01

    A method has been developed and established for residue determination of benazolin-ethyl in soil and rape seed samples by gas chromatography with electron capture detection (GC-ECD). Limits of quantification of the method are 0.005 mg/kg for both soil and rape seed, which are sufficiently below the maximum residue limit, and the limit of detection is 0.0023 ng. The average recoveries of the analyte range from 85.89 to 105.84% with relative standard deviations (coefficient of variation) less than 5.53% at the three spike levels (0.005, 0.1 and 0.5 mg/kg). The half-life of benazolin-ethyl in soil from the experimental field is 4.62 days. The final residues of benazolin-ethyl in soil and rape seed samples are lower than 0.005 mg/kg at harvest time. Direct confirmation of the analyte in real samples is achieved by GC-mass spectrometry. It is demonstrated that the proposed method is simple, rapid and efficient, and reliable to detect benazolin-ethyl residues in soil and rape seed samples.

  7. Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink.

    PubMed

    Díaz-Santana, Oscar; Vega-Moreno, Daura; Conde-Hardisson, Francisco

    2017-09-15

    An extraction and determination method is shown for the analysis of dyes and solvents present in two types of ballpoint pen inks that are deposited onto paper. Ink extracts are analysed using a combination of gas chromatography with mass spectrometry (GC-MS), and high-pressure liquid chromatography with photodiode array detection (HPLC-DAD), within a single sample extraction procedure. Seventeen solvents and thirteen dyes contained in two Montblanc ® inks (black and blue) were monitored for 45 months at monthly intervals, in order to determine variations in the concentrations of the compounds over time. We also studied the relative variations between different compounds and the generation of degradation products such as phenol. The concentration data obtained from these compounds during their exposure have been analysed and a multiple regression model is developed for each ink type that allows an estimate of the exposure time of the ink on paper with a maximum error of between 4 and 7 months. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. The limitations on organic detection in Mars-like soils by thermal volatilization-gas chromatography-MS and their implications for the Viking results.

    PubMed

    Navarro-González, Rafael; Navarro, Karina F; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P

    2006-10-31

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)-gas chromatography (GC)-MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV-GC-MS may be blind to low levels of organics on Mars. A comparison between TV-GC-MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10-90 mug of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV-GC-MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO(2)) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50-700 ppm of CO(2) by TV-GC-MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV-GC-MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life.

  9. An Electronic Finding Aid Using Extensible Markup Language (XML) and Encoded Archival Description (EAD).

    ERIC Educational Resources Information Center

    Chang, May

    2000-01-01

    Describes the development of electronic finding aids for archives at the University of Illinois, Urbana-Champaign that used XML (extensible markup language) and EAD (encoded archival description) to enable more flexible information management and retrieval than using MARC or a relational database management system. EAD template is appended.…

  10. Gas chromatography with flame photometric detection of 31 organophosphorus pesticide residues in Alpinia oxyphylla dried fruits.

    PubMed

    Zhao, Xiangsheng; Kong, Weijun; Wei, Jianhe; Yang, Meihua

    2014-11-01

    A simple, rapid and effective gas chromatography-flame photometric detection method was established for simultaneous multi-component determination of 31 organophosphorus pesticides (OPPs) residues in Alpinia oxyphylla, which is widely consumed as a traditional medicine and food in China. Sample preparation was completed in a single step without any clean-up procedure. All pesticides expressed good linear relationships between 0.004 and 1.0 μg/mL with correlation coefficients higher than 0.9973. The method gave satisfactory recoveries for most pesticides. The limits of detection varied from 1 to 10 ng/mL, and the limits of quantification (LOQs) were between 4 and 30 ng/mL. The proposed method was successfully applied to 55 commercial samples purchased from five different areas. Five pesticide residues were detected in four (7.27%) samples. The positive samples were confirmed by gas chromatography with tandem mass spectrometry (GC-MS/MS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Detection of the Spermicide Nonoxynol-9 Via GC-MS

    NASA Astrophysics Data System (ADS)

    Musah, Rabi A.; Vuong, Angela L.; Henck, Colin; Shepard, Jason R. E.

    2012-05-01

    The spermicide nonoxynol-9 is actually a complex mixture of dozens of closely related amphiphilic compounds, and the chemical properties of this assortment significantly hamper its characterization by GC-MS. The inability to perform routine GC-MS testing on nonoxynol-9 has limited its evidentiary value in forensic casework, which relies heavily on this technique for analysis. A disturbing trend in sexual assault is the use of condoms by assailants, to avoid leaving behind DNA evidence that can connect a perpetrator to a victim. This observation necessitates the development of alternative methods for the analysis of trace evidence that can show causal links between a victim and a suspect. Detection of lubricants associated with sexual assault is one such way to establish this connection. The development of GC-MS methods that permit facile detection of both nonoxynol-9 alone and nonoxynol-9 extracted from other complex matrices that have potential as trace evidence in sexual assault is reported. A detection limit of 2.14 μg of nonoxynol-9 is demonstrated, and a detailed mass spectral profile that elaborates on what is known of its structure is provided.

  12. Clandestine laboratory scene investigation and processing using portable GC/MS

    NASA Astrophysics Data System (ADS)

    Matejczyk, Raymond J.

    1997-02-01

    This presentation describes the use of portable gas chromatography/mass spectrometry for on-scene investigation and processing of clandestine laboratories. Clandestine laboratory investigations present special problems to forensic investigators. These crime scenes contain many chemical hazards that must be detected, identified and collected as evidence. Gas chromatography/mass spectrometry performed on-scene with a rugged, portable unit is capable of analyzing a variety of matrices for drugs and chemicals used in the manufacture of illicit drugs, such as methamphetamine. Technologies used to detect various materials at a scene have particular applications but do not address the wide range of samples, chemicals, matrices and mixtures that exist in clan labs. Typical analyses performed by GC/MS are for the purpose of positively establishing the identity of starting materials, chemicals and end-product collected from clandestine laboratories. Concerns for the public and investigator safety and the environment are also important factors for rapid on-scene data generation. Here is described the implementation of a portable multiple-inlet GC/MS system designed for rapid deployment to a scene to perform forensic investigations of clandestine drug manufacturing laboratories. GC/MS has long been held as the 'gold standard' in performing forensic chemical analyses. With the capability of GC/MS to separate and produce a 'chemical fingerprint' of compounds, it is utilized as an essential technique for detecting and positively identifying chemical evidence. Rapid and conclusive on-scene analysis of evidence will assist the forensic investigators in collecting only pertinent evidence thereby reducing the amount of evidence to be transported, reducing chain of custody concerns, reducing costs and hazards, maintaining sample integrity and speeding the completion of the investigative process.

  13. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PESTICIDE SAMPLES BY GC/MS (BCO-L-15.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography/mass spectrometry (GC/MS) of pesticides in a variety of matrices, including air, house dust, soil, and handwipes. This analysis involves automated gas GC/MS analysis us...

  14. Hyphenated and comprehensive liquid chromatography × gas chromatography-mass spectrometry for the identification of Mycobacterium tuberculosis.

    PubMed

    Mourão, Marta P B; Denekamp, Ilse; Kuijper, Sjoukje; Kolk, Arend H J; Janssen, Hans-Gerd

    2016-03-25

    Tuberculosis is one of the world's most emerging public health problems, particularly in developing countries. Chromatography based methods have been used to tackle this epidemic by focusing on biomarker detection. Unfortunately, interferences from lipids in the sputum matrix, particularly cholesterol, adversely affect the identification and detection of the marker compounds. The present contribution describes the serial combination of normal phase liquid chromatography (NPLC) with thermally assisted hydrolysis and methylation followed by gas chromatography-mass spectrometry (THM-GC-MS) to overcome the difficulties of biomarker evaluation. The in-series combination consists of an LC analysis where fractions are collected and then transferred to the THM-GC-MS system. This was either done with comprehensive coupling, transferring all the fractions, or with hyphenated interfacing, i.e. off-line multi heart-cutting, transferring only selected fractions. Owing to the high sensitivity and selectivity of LC as a sample pre-treatment method, and to the high specificity of the MS as a detector, this analytical approach, NPLC × THM-GC-MS, is extremely sensitive. The results obtained indicate that this analytical set-up is able to detect down to 1 × 10(3) mycobacteria/mL of Mycobacterium tuberculosis strain 124, spiked in blank sputum samples. It is a powerful analytical tool and also has great potential for full automation. If further studies demonstrate its usefulness when applied blind in real sputum specimens, this technique could compete with the current smear microscopy in the early diagnosis of tuberculosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Comparative Analysis of Volatile Composition in Chinese Truffles via GC × GC/HR-TOF/MS and Electronic Nose

    PubMed Central

    Zhang, Ning; Chen, Haitao; Sun, Baoguo; Mao, Xueying; Zhang, Yuyu; Zhou, Ying

    2016-01-01

    To compare the volatile compounds of Chinese black truffle and white truffle from Yunnan province, this study presents the application of a direct solvent extraction/solvent-assisted flavor evaporation (DSE-SAFE) coupled with a comprehensive two-dimensional gas chromatography (GC × GC) high resolution time-of-flight mass spectrometry (HR-TOF/MS) and an electronic nose. Both of the analytical methods could distinguish the aroma profile of the two samples. In terms of the overall profile of truffle samples in this research, more kinds of acids were detected via the method of DSE-SAFE. Besides, compounds identified in black truffle (BT), but not in white truffle (WT), or vice versa, and those detected in both samples at different levels were considered to play an important role in differentiating the two samples. According to the analysis of electronic nose, the two samples could be separated, as well. PMID:27058524

  16. One-step extraction and quantitation of toxic alcohols and ethylene glycol in plasma by capillary gas chromatography (GC) with flame ionization detection (FID).

    PubMed

    Orton, Dennis J; Boyd, Jessica M; Affleck, Darlene; Duce, Donna; Walsh, Warren; Seiden-Long, Isolde

    2016-01-01

    Clinical analysis of volatile alcohols (i.e. methanol, ethanol, isopropanol, and metabolite acetone) and ethylene glycol (EG) generally employs separate gas chromatography (GC) methods for analysis. Here, a method for combined analysis of volatile alcohols and EG is described. Volatile alcohols and EG were extracted with 2:1 (v:v) acetonitrile containing internal standards (IS) 1,2 butanediol (for EG) and n-propanol (for alcohols). Samples were analyzed on an Agilent 6890 GC FID. The method was evaluated for precision, accuracy, reproducibility, linearity, selectivity and limit of quantitation (LOQ), followed by correlation to existing GC methods using patient samples, Bio-Rad QC, and in-house prepared QC material. Inter-day precision was from 6.5-11.3% CV, and linearity was verified from down to 0.6mmol/L up to 150mmol/L for each analyte. The method showed good recovery (~100%) and the LOQ was calculated to be between 0.25 and 0.44mmol/L. Patient correlation against current GC methods showed good agreement (slopes from 1.03-1.12, and y-intercepts from 0 to 0.85mmol/L; R(2)>0.98; N=35). Carryover was negligible for volatile alcohols in the measuring range, and of the potential interferences tested, only toluene and 1,3 propanediol interfered. The method was able to resolve 2,3 butanediol, diethylene glycol, and propylene glycol in addition to the peaks quantified. Here we describe a simple procedure for simultaneous analysis of EG and volatile alcohols that comes at low cost and with a simple liquid-liquid extraction requiring no derivitization to obtain adequate sensitivity for clinical specimens. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Application of gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry (GC-MS/C/IRMS) to detect the abuse of 17β-estradiol in cattle.

    PubMed

    Janssens, Geert; Mangelinckx, Sven; Courtheyn, Dirk; Prévost, Stéphanie; De Poorter, Geert; De Kimpe, Norbert; Le Bizec, Bruno

    2013-07-31

    Although the ability to differentiate between endogenous steroids and synthetic homologues on the basis of their (13)C/(12)C isotopic ratio has been known for over a decade, this technique has been scarcely implemented for food safety purposes. In this study, a method was developed using gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry (GC-MS/C/IRMS) to demonstrate the abuse of 17β-estradiol in cattle, by comparison of the (13)C/(12)C ratios of the main metabolite 17α-estradiol and an endogenous reference compound (ERC), 5-androstene-3β,17α-diol, in bovine urine. The intermediate precisions were determined as 0.46 and 0.26‰ for 5-androstene-3β,17α-diol and 17α-estradiol, respectively. This is, to the authors' knowledge, the first reported use of GC-MS/C/IRMS for the analysis of steroid compounds for food safety issues.

  18. Direct Measurement of Trace Elemental Mercury in Hydrocarbon Matrices by Gas Chromatography with Ultraviolet Photometric Detection.

    PubMed

    Gras, Ronda; Luong, Jim; Shellie, Robert A

    2015-11-17

    We introduce a technique for the direct measurement of elemental mercury in light hydrocarbons such as natural gas. We determined elemental mercury at the parts-per-trillion level with high precision [<3% RSD (n = 20 manual injection)] using gas chromatography with ultraviolet photometric detection (GC-UV) at 254 nm. Our approach requires a small sample volume (1 mL) and does not rely on any form of sample preconcentration. The GC-UV separation employs an inert divinylbenzene porous layer open tubular column set to separate mercury from other components in the sample matrix. We incorporated a 10-port gas-sampling valve in the GC-UV system, which enables automated sampling, as well as back flushing capability to enhance system cleanliness and sample throughput. Total analysis time is <2 min, and the procedure is linear over a range of 2-83 μg/m(3) [correlation coefficient of R(2) = 0.998] with a measured recovery of >98% over this range.

  19. GC/HRSIR as a Complementary Technique to GC/ECNIMS

    EPA Science Inventory

    Gas chromatography/electron capture negative ion mass spectrometry (GC/ECNIMS) is a highly selective and sensitive technique for the analysis of appropriate analytes in complex matrices. Its major drawback is often the lack of fragmentation indicative of structure that can be use...

  20. ADAP-GC 3.0: Improved Peak Detection and Deconvolution of Co-eluting Metabolites from GC/TOF-MS Data for Metabolomics Studies

    PubMed Central

    Ni, Yan; Su, Mingming; Qiu, Yunping; Jia, Wei

    2017-01-01

    ADAP-GC is an automated computational pipeline for untargeted, GC-MS-based metabolomics studies. It takes raw mass spectrometry data as input and carries out a sequence of data processing steps including construction of extracted ion chromatograms, detection of chromatographic peak features, deconvolution of co-eluting compounds, and alignment of compounds across samples. Despite the increased accuracy from the original version to version 2.0 in terms of extracting metabolite information for identification and quantitation, ADAP-GC 2.0 requires appropriate specification of a number of parameters and has difficulty in extracting information of compounds that are in low concentration. To overcome these two limitations, ADAP-GC 3.0 was developed to improve both the robustness and sensitivity of compound detection. In this paper, we report how these goals were achieved and compare ADAP-GC 3.0 against three other software tools including ChromaTOF, AnalyzerPro, and AMDIS that are widely used in the metabolomics community. PMID:27461032

  1. ADAP-GC 3.0: Improved Peak Detection and Deconvolution of Co-eluting Metabolites from GC/TOF-MS Data for Metabolomics Studies.

    PubMed

    Ni, Yan; Su, Mingming; Qiu, Yunping; Jia, Wei; Du, Xiuxia

    2016-09-06

    ADAP-GC is an automated computational pipeline for untargeted, GC/MS-based metabolomics studies. It takes raw mass spectrometry data as input and carries out a sequence of data processing steps including construction of extracted ion chromatograms, detection of chromatographic peak features, deconvolution of coeluting compounds, and alignment of compounds across samples. Despite the increased accuracy from the original version to version 2.0 in terms of extracting metabolite information for identification and quantitation, ADAP-GC 2.0 requires appropriate specification of a number of parameters and has difficulty in extracting information on compounds that are in low concentration. To overcome these two limitations, ADAP-GC 3.0 was developed to improve both the robustness and sensitivity of compound detection. In this paper, we report how these goals were achieved and compare ADAP-GC 3.0 against three other software tools including ChromaTOF, AnalyzerPro, and AMDIS that are widely used in the metabolomics community.

  2. PyMS: a Python toolkit for processing of gas chromatography-mass spectrometry (GC-MS) data. Application and comparative study of selected tools.

    PubMed

    O'Callaghan, Sean; De Souza, David P; Isaac, Andrew; Wang, Qiao; Hodkinson, Luke; Olshansky, Moshe; Erwin, Tim; Appelbe, Bill; Tull, Dedreia L; Roessner, Ute; Bacic, Antony; McConville, Malcolm J; Likić, Vladimir A

    2012-05-30

    Gas chromatography-mass spectrometry (GC-MS) is a technique frequently used in targeted and non-targeted measurements of metabolites. Most existing software tools for processing of raw instrument GC-MS data tightly integrate data processing methods with graphical user interface facilitating interactive data processing. While interactive processing remains critically important in GC-MS applications, high-throughput studies increasingly dictate the need for command line tools, suitable for scripting of high-throughput, customized processing pipelines. PyMS comprises a library of functions for processing of instrument GC-MS data developed in Python. PyMS currently provides a complete set of GC-MS processing functions, including reading of standard data formats (ANDI- MS/NetCDF and JCAMP-DX), noise smoothing, baseline correction, peak detection, peak deconvolution, peak integration, and peak alignment by dynamic programming. A novel common ion single quantitation algorithm allows automated, accurate quantitation of GC-MS electron impact (EI) fragmentation spectra when a large number of experiments are being analyzed. PyMS implements parallel processing for by-row and by-column data processing tasks based on Message Passing Interface (MPI), allowing processing to scale on multiple CPUs in distributed computing environments. A set of specifically designed experiments was performed in-house and used to comparatively evaluate the performance of PyMS and three widely used software packages for GC-MS data processing (AMDIS, AnalyzerPro, and XCMS). PyMS is a novel software package for the processing of raw GC-MS data, particularly suitable for scripting of customized processing pipelines and for data processing in batch mode. PyMS provides limited graphical capabilities and can be used both for routine data processing and interactive/exploratory data analysis. In real-life GC-MS data processing scenarios PyMS performs as well or better than leading software packages. We

  3. Dehydration of Methylcyclohexanol Isomers in the Undergraduate Organic Laboratory and Product Analysis by Gas Chromatography-Mass Spectroscopy (GC-MS)

    ERIC Educational Resources Information Center

    Clennan, Malgorzata M.; Clennan, Edward L.

    2011-01-01

    Dehydrations of "cis"- and "trans"-2-methylcyclohexanol mixtures were carried out with 60% sulfuric acid at 78-80 [degrees]C as a function of time and the products were identified by gas chromatography-mass spectroscopy (GC-MS) analysis. The compounds identified in the reaction mixtures include alkenes, 1-, 3-, and 4-methylcyclohexenes and…

  4. Gc protein-derived macrophage activating factor (GcMAF): isoelectric focusing pattern and tumoricidal activity.

    PubMed

    Mohamad, Saharuddin Bin; Nagasawa, Hideko; Sasaki, Hideyuki; Uto, Yoshihiro; Nakagawa, Yoshinori; Kawashima, Ken; Hori, Hitoshi

    2003-01-01

    Gc protein is the precursor for Gc protein-derived macrophage activating factor (GcMAF), with three phenotypes: Gc1f, Gc1s and Gc2, based on its electrophoretic mobility. The difference in electrophoretic mobility is because of the difference in its posttranslational sugar moiety composition. We compared the difference between Gc protein and GcMAF electrophoretic mobility using the isoelectric focusing (IEF) method. The tumoricidal activity of GcMAF-treated macrophage was evaluated after coculture with L-929 cell. The tumoricidal mechanism was investigated using TNF bioassay and nitric oxide (NO) release. The difference in Gc protein and GcMAF electrophoretic mobility was detected. The tumoricidal activity of GcMAF-treated macrophage was detected, but no release of TNF and NO was detected. The difference of isoelectric focusing mobility in Gc protein and GcMAF would be useful to develop a GcMAF detection method. GcMAF increased macrophage tumoricidal activity but TNF and NO release were not involved in the mechanism.

  5. Gas Chromatography.

    ERIC Educational Resources Information Center

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  6. Potential of gas chromatography-orthogonal acceleration time-of-flight mass spectrometry (GC-oaTOFMS) in flavor research.

    PubMed

    Fay, Laurent B; Newton, Anthony; Simian, Hervé; Robert, Fabien; Douce, David; Hancock, Peter; Green, Martin; Blank, Imre

    2003-04-23

    Gas chromatography-orthogonal acceleration time-of-flight mass spectrometry (GC-oaTOFMS) is an emerging technique offering a straightforward access to a resolving power up to 7000. This paper deals with the use of GC-oaTOFMS to identify the flavor components of a complex seafood flavor extract and to quantify furanones formed in model Maillard reactions. A seafood extract was selected as a representative example for complex food flavors and was previously analyzed using GC-quadrupole MS, leaving several molecules unidentified. GC-oaTOFMS analysis was focused on these unknowns to evaluate its potential in flavor research, particularly for determining exact masses. N-Methyldithiodimethylamine, 6-methyl-5-hepten-2-one, and tetrahydro-2,4-dimethyl-4H-pyrrolo[2,1-d]-1,3,5-dithiazine were successfully identified on the basis of the precise mass determination of their molecular ions and their major fragments. A second set of experiments was performed to test the capabilities of the GC-oaTOFMS for quantification. Calibration curves were found to be linear over a dynamic range of 10(3) for the quantification of furanones. The quantitative data obtained using GC-oaTOFMS confirmed earlier results that the formation of 4-hydroxy-2,5-dimethyl-3(2H)-furanone was favored in the xylose/glycine model reaction and 2(or 5)-ethyl-4-hydroxy-5(or 2)-methyl-3(2H)-furanone in the xylose/alanine model reaction. It was concluded that GC-oaTOFMS may become a powerful analytical tool for the flavor chemist for both identification and quantification purposes, the latter in particular when combined with stable isotope dilution assay.

  7. Development and validation of a sensitive thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) method for the determination of phosgene in air samples.

    PubMed

    Juillet, Y; Dubois, C; Bintein, F; Dissard, J; Bossée, A

    2014-08-01

    A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography-mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95%). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention.

  8. Electroantennogram and behavioral responses of the imported fire ant, Solenopsis invicta Buren, to an alarm pheromone component and its analogues.

    PubMed

    Guan, Di; Lu, Yong-Yue; Liao, Xiao-Lan; Wang, Lei; Chen, Li

    2014-12-10

    A characteristic behavior in ants is to move rapidly to emission sources of alarm pheromones. The addition of ant alarm pheromones to bait is expected to enhance its attractiveness. To search for candidate compounds for bait enhancement in fire ant control, 13 related alkylpyrazine analogues in addition to synthetic alarm pheromone component were evaluated for electroantennogram (EAG) and behavioral activities in Solenopsis invicta. Most compounds elicited dose-dependent EAG and behavioral responses. There exists a correlation between the EAG and behavioral responses. Among the 14 tested alkylpyrazines, three compounds, 2-ethyl-3,6(5)-dimethyl pyrazine (1), 2,3,5-trimethylpyrazine (7), and 2,3-diethyl-5-methylpyrazine (12), elicited significant alarm responses at a dose range of 0.1-1000 ng. Further bait discovery bioassay with the three most active alkylpyrazines demonstrated that food bait accompanied by sample-treated filter paper disk attracted significantly more fire ant workers in the first 15 min period. EAG and behavioral bioassays with pure pheromone isomers accumulated by semi-preparative high-performance liquid chromatography demonstrated that 2-ethyl-3,6-dimethylpyrazine was significantly more active than 2-ethyl-3,5-dimethylpyrazine.

  9. Limit of detection of 15{sub N} by gas-chromatography atomic emission detection: Optimization using an experimental design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deruaz, D.; Bannier, A.; Pionchon, C.

    1995-08-01

    This paper deals with the optimal conditions for the detection of {sup 15}N determined using a four-factor experimental design from [2{sup 13}C,-1,3 {sup 15}N] caffeine measured with an atomic emission detector (AED) coupled to gas chromatography (GC). Owing to the capability of a photodiodes array, AED can simultaneously detect several elements using their specific emission lines within a wavelength range of 50 nm. So, the emissions of {sup 15}N and {sup 14}N are simultaneously detected at 420.17 nm and 421.46 nm respectively. Four independent experimental factors were tested (1) helium flow rate (plasma gas); (2) methane pressure (reactant gas); (3)more » oxygen pressure; (4) hydrogen pressure. It has been shown that these four gases had a significant influence on the analytical response of {sup 15}N. The linearity of the detection was determined using {sup 15}N amounts ranging from 1.52 pg to 19 ng under the optimal conditions obtained from the experimental design. The limit of detection was studied using different methods. The limits of detection of {sup 15}N was 1.9 pg/s according to the IUPAC method (International-Union of Pure and Applied Chemistry). The method proposed by Quimby and Sullivan gave a value of 2.3 pg/s and that of Oppenheimer gave a limit of 29 pg/s. For each determination, and internal standard: 1-isobutyl-3.7 dimethylxanthine was used. The results clearly demonstrate that GC AED is sensitive and selective enough to detect and measure {sup 15}N-labelled molecules after gas chromatographic separation.« less

  10. Monitoring of CoS 2 reactions using high-temperature XRD coupled with gas chromatography (GC)

    DOE PAGES

    Rodriguez, Mark A.; Coker, Eric Nicholas; Griego, James J. M.; ...

    2016-04-18

    High-temperature X-ray diffraction with concurrent gas chromatography (GC) was used to study cobalt disulfide cathode pellets disassembled from thermal batteries. When CoS 2 cathode materials were analyzed in an air environment, oxidation of the K(Br, Cl) salt phase in the cathode led to the formation of K 2SO 4 that subsequently reacted with the pyrite-type CoS 2 phase leading to cathode decomposition between ~260 and 450 °C. Here, independent thermal analysis experiments, i.e. simultaneous thermogravimetric analysis/differential scanning calorimetry/mass spectrometry (MS), augmented the diffraction results and support the overall picture of CoS 2 decomposition. Both gas analysis measurements (i.e. GC andmore » MS) from the independent experiments confirmed the formation of SO 2 off-gas species during breakdown of the CoS 2. In contrast, characterization of the same cathode material under inert conditions showed the presence of CoS 2 throughout the entire temperature range of analysis.« less

  11. Outdoor and indoor benzene evaluation by GC-FID and GC-MS/MS.

    PubMed

    Sousa, José A; Domingues, Valentina F; Rosas, Mónica S; Ribeiro, Susana O; Alvim-Ferraz, Conceiçao M; Delerue-Matos, Cristina F

    2011-01-01

    The evaluation of benzene in different environments such as indoor (with and without tobacco smoke), a city area, countryside, gas stations and near exhaust pipes from cars running on different types of fuels was performed. The samples were analyzed using gas chromatography (GC) with flame ionization detection (FID) and tandem mass spectrometric detection (MS/MS) (to confirm the identification of benzene in the air samples). Operating conditions for the GC-MS analysis were optimized as well as the sampling and sample preparation. The results obtained in this work indicate that i) the type of fuel directly influences the benzene concentration in the air. Gasoline with additives provided the highest amount of benzene followed by unleaded gasoline and diesel; ii) the benzene concentration in the gas station was always higher than the advisable limit established by law (5 μg m⁻³) and during the unloading of gasoline the achieved concentration was 8371 μg m⁻³; iii) the data from the countryside (Taliscas) and the urban city (Matosinhos) were below 5 μg m⁻³ except 5 days after a fire on a petroleum refinery plant located near the city; iv) it was proven that in coffee shops where smoking is allowed the benzene concentration is higher (6 μg m⁻³) than in coffee shops where this is forbidden (4 μg m⁻³). This method may also be helpful for environmental analytical chemists who use GC-MS/MS for the confirmation or/and quantification of benzene.

  12. Characterization of oils and fats by 1H NMR and GC/MS fingerprinting: classification, prediction and detection of adulteration.

    PubMed

    Fang, Guihua; Goh, Jing Yeen; Tay, Manjun; Lau, Hiu Fung; Li, Sam Fong Yau

    2013-06-01

    The correct identification of oils and fats is important to consumers from both commercial and health perspectives. Proton nuclear magnetic resonance ((1)H NMR) spectroscopy, gas chromatography-mass spectrometry (GC/MS) fingerprinting and chemometrics were employed successfully for the quality control of oils and fats. Principal component analysis (PCA) of both techniques showed group clustering of 14 types of oils and fats. Partial least squares discriminant analysis (PLS-DA) and orthogonal projections to latent structures discriminant analysis (OPLS-DA) using GC/MS data had excellent classification sensitivity and specificity compared to models using NMR data. Depending on the availability of the instruments, data from either technique can effectively be applied for the establishment of an oils and fats database to identify unknown samples. Partial least squares (PLS) models were successfully established for the detection of as low as 5% of lard and beef tallow spiked into canola oil, thus illustrating possible applications in Islamic and Jewish countries. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Cross validation of gas chromatography-flame photometric detection and gas chromatography-mass spectrometry methods for measuring dialkylphosphate metabolites of organophosphate pesticides in human urine.

    PubMed

    Prapamontol, Tippawan; Sutan, Kunrunya; Laoyang, Sompong; Hongsibsong, Surat; Lee, Grace; Yano, Yukiko; Hunter, Ronald Elton; Ryan, P Barry; Barr, Dana Boyd; Panuwet, Parinya

    2014-01-01

    We report two analytical methods for the measurement of dialkylphosphate (DAP) metabolites of organophosphate pesticides in human urine. These methods were independently developed/modified and implemented in two separate laboratories and cross validated. The aim was to develop simple, cost effective, and reliable methods that could use available resources and sample matrices in Thailand and the United States. While several methods already exist, we found that direct application of these methods required modification of sample preparation and chromatographic conditions to render accurate, reliable data. The problems encountered with existing methods were attributable to urinary matrix interferences, and differences in the pH of urine samples and reagents used during the extraction and derivatization processes. Thus, we provide information on key parameters that require attention during method modification and execution that affect the ruggedness of the methods. The methods presented here employ gas chromatography (GC) coupled with either flame photometric detection (FPD) or electron impact ionization-mass spectrometry (EI-MS) with isotopic dilution quantification. The limits of detection were reported from 0.10ng/mL urine to 2.5ng/mL urine (for GC-FPD), while the limits of quantification were reported from 0.25ng/mL urine to 2.5ng/mL urine (for GC-MS), for all six common DAP metabolites (i.e., dimethylphosphate, dimethylthiophosphate, dimethyldithiophosphate, diethylphosphate, diethylthiophosphate, and diethyldithiophosphate). Each method showed a relative recovery range of 94-119% (for GC-FPD) and 92-103% (for GC-MS), and relative standard deviations (RSD) of less than 20%. Cross-validation was performed on the same set of urine samples (n=46) collected from pregnant women residing in the agricultural areas of northern Thailand. The results from split sample analysis from both laboratories agreed well for each metabolite, suggesting that each method can produce

  14. Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts from urban dust and diesel standard reference materials using a 2D-LC/2D-GC system.

    PubMed

    Ahmed, Trifa M; Lim, Hwanmi; Bergvall, Christoffer; Westerholm, Roger

    2013-10-01

    A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

  15. Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  16. Lipids and Fatty Acids in Algae: Extraction, Fractionation into Lipid Classes, and Analysis by Gas Chromatography Coupled with Flame Ionization Detector (GC-FID).

    PubMed

    Guihéneuf, Freddy; Schmid, Matthias; Stengel, Dagmar B

    2015-01-01

    Despite the number of biochemical studies exploring algal lipids and fatty acid biosynthesis pathways and profiles, analytical methods used by phycologists for this purpose are often diverse and incompletely described. Potential confusion and potential variability of the results between studies can therefore occur due to change of protocols for lipid extraction and fractionation, as well as fatty acid methyl esters (FAME) preparation before gas chromatography (GC) analyses. Here, we describe a step-by-step procedure for the profiling of neutral and polar lipids using techniques such as solid-liquid extraction (SLE), thin-layer chromatography (TLC), and gas chromatography coupled with flame ionization detector (GC-FID). As an example, in this protocol chapter, analyses of neutral and polar lipids from the marine microalga Pavlova lutheri (an EPA/DHA-rich haptophyte) will be outlined to describe the distribution of fatty acid residues within its major lipid classes. This method has been proven to be a reliable technique to assess changes in lipid and fatty acid profiles in several other microalgal species and seaweeds.

  17. Disentangling oil weathering using GC x GC. 2. Mass transfer calculations.

    PubMed

    Arey, J Samuel; Nelson, Robert K; Plata, Desiree L; Reddy, Christopher M

    2007-08-15

    Hydrocarbon mass transfers to the atmosphere and water column drive the early weathering of oil spills and also control the chemical exposures of many coastal wildlife species. However, in the field, mass transfer rates of individual hydrocarbons to air and water are often uncertain. In the Part 1 companion to this paper, we used comprehensive two-dimensional gas chromatography (GC x GC) to identify distinct signatures of evaporation and dissolution encoded in the compositional evolution of weathered oils. In Part 2, we further investigate patterns of mass removal in GC x GC chromatograms using a mass transfer model. The model was tailored to conditions at a contaminated beach on Buzzards Bay, MA, after the 2003 Bouchard 120 oil spill. The model was applied to all resolved hydrocarbon compounds in the C11-C24 boiling range, based on their GC x GC-estimated vapor pressures and aqueous solubilities. With no fitted parameters, the model successfully predicted GC x GC chromatogram patterns of mass removal associated with evaporation, water-washing, and diffusion-limited transport. This enabled a critical field evaluation of the mass transfer model and also allowed mass apportionment estimates of hundreds of individual hydrocarbon compounds to air and water. Ultimately, this method should improve assessments of wildlife exposures to oil spill hydrocarbons.

  18. Aroma characterization of chinese rice wine by gas chromatography-olfactometry, chemical quantitative analysis, and aroma reconstitution.

    PubMed

    Chen, Shuang; Xu, Yan; Qian, Michael C

    2013-11-27

    The aroma profile of Chinese rice wine was investigated in this study. The volatile compounds in a traditional Chinese rice wine were extracted using Lichrolut EN and further separated by silica gel normal phase chromatography. Seventy-three aroma-active compounds were identified by gas chromatography-olfactometry (GC-O) and gas chromatography-mass spectrometry (GC-MS). In addition to acids, esters, and alcohols, benzaldehyde, vanillin, geosmin, and γ-nonalactone were identified to be potentially important to Chinse rice wine. The concentration of these aroma-active compounds in the Chinese rice wine was further quantitated by combination of four different methods, including headsapce-gas chromatography, solid phase microextraction-gas chromatography (SPME)-GC-MS, solid-phase extraction-GC-MS, and SPME-GC-pulsed flame photometric detection (PFPD). Quantitative results showed that 34 aroma compounds were at concentrations higher than their corresponding odor thresholds. On the basis of the odor activity values (OAVs), vanillin, dimethyl trisulfide, β-phenylethyl alcohol, guaiacol, geosmin, and benzaldehyde could be responsible for the unique aroma of Chinese rice wine. An aroma reconstitution model prepared by mixing 34 aroma compounds with OAVs > 1 in an odorless Chinese rice wine matrix showed a good similarity to the aroma of the original Chinese rice wine.

  19. Monitoring of selected skin- and breath-borne volatile organic compounds emitted from the human body using gas chromatography ion mobility spectrometry (GC-IMS).

    PubMed

    Mochalski, Paweł; Wiesenhofer, Helmut; Allers, Maria; Zimmermann, Stefan; Güntner, Andreas T; Pineau, Nicolay J; Lederer, Wolfgang; Agapiou, Agapios; Mayhew, Christopher A; Ruzsanyi, Veronika

    2018-02-15

    Human smuggling and associated cross-border crimes have evolved as a major challenge for the European Union in recent years. Of particular concern is the increasing trend of smuggling migrants hidden inside shipping containers or trucks. Therefore, there is a growing demand for portable security devices for the non-intrusive and rapid monitoring of containers to detect people hiding inside. In this context, chemical analysis of volatiles organic compounds (VOCs) emitted from the human body is proposed as a locating tool. In the present study, an in-house made ion mobility spectrometer coupled with gas chromatography (GC-IMS) was used to monitor the volatile moieties released from the human body under conditions that mimic entrapment. A total of 17 omnipresent volatile compounds were identified and quantified from 35 ion mobility peaks corresponding to human presence. These are 7 aldehydes (acrolein, 2-methylpropanal, 3-methylbutanal, 2-ethacrolein, n-hexanal, n-heptanal, benzaldehyde), 3 ketones (acetone, 2-pentanone, 4-methyl-2-pentanone), 5 esters (ethyl formate, ethyl propionate, vinyl butyrate, butyl acetate, ethyl isovalerate), one alcohol (2-methyl-1-propanol) and one organic acid (acetic acid). The limits of detection (0.05-7.2 ppb) and relative standard deviations (0.6-11%) should be sufficient for detecting these markers of human presence in field conditions. This study shows that GC-IMS can be used as a portable field detector of hidden or entrapped people. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Behavioral and electroantennogram responses of plum curculio, Conotrachelus nenuphar, to selected noxious plant extracts and insecticides

    PubMed Central

    Gӧkçe, A.; Stelinski, L. L.; Nortman, D. R.; Bryan, W. W.; Whalon, M. E.

    2014-01-01

    Abstract Behavioral and electroantennogram responses of plum curculio, Conotrachelus nenuphar (Herbst) (Coleoptera: Curculionidae), adults were tested for several methanolic plant extracts and organically approved insecticides. Plant extracts were evaluated for their potential as antifeedants or oviposition deterrents. These extract responses were also compared to those elicited by the non-neurotoxic, organic irritant-insecticide kaolin clay. Both sexes of plum curculio exhibited antennal response as measured by electroantennogram, which ranged from 0.2 to 1.1 mV, to plant extracts and the organic irritant/insecticide, with the greatest response to the extract of rough cocklebur, Xanthium strumarium L. (1.1 mV). No choice tests were conducted to compare feeding and oviposition by plum curculio on untreated apples or on apples treated with one of the extracts or the insecticide. The insecticide pyrethrum and extracts of X. strumarium and greater burdock, Arctium lappa L., significantly reduced feeding. Also, pyrethrum , A. lappa, Humulus lupulus L. (common hop), X. strumarium, and Verbascum songaricum Schrenk extracts completely inhibited egg deposition. In no-choice assays, the effects of kaolin clay with incorporated plant extracts on plum curculio feeding and oviposition were monitored as complementary tests. A. lappa-kaolin, H. lupulus –kaolin, and X. strumarium-kaolin mixtures significantly reduced the feeding of plum curculio compared to the control or kaolin clay alone. Each of the plant extract-kaolin mixtures evaluated, with the exception of Bifora radians Bieberstein (wild bishop), completely inhibited plum curculio oviposition as compared to controls. PMID:25368046

  1. METHOD 530 DETERMINATION OF SELECT SEMIVOLATILE ORGANIC CHEMICALS IN DRINKING WATER BY SOLID PHASE EXTRACTION AND GAS CHROMATOGRAPHY/ MASS SPECTROMETRY (GC/MS)

    EPA Science Inventory

    1.1. This is a gas chromatography/mass spectrometry (GC/MS) method for the determination of selected semivolatile organic compounds in drinking waters. Accuracy and precision data have been generated in reagent water, and in finished ground and surface waters for the compounds li...

  2. Global gas chromatography/time-of-flight mass spectrometry (GC/TOFMS)-based metabonomic profiling of lyophilized human feces.

    PubMed

    Phua, Lee Cheng; Koh, Poh Koon; Cheah, Peh Yean; Ho, Han Kiat; Chan, Eric Chun Yong

    2013-10-15

    Gas chromatography mass spectrometry (GC/MS)-based fecal metabonomics represents a powerful systems biology approach for elucidating metabolic biomarkers of lower gastrointestinal tract (GIT) diseases. Unlike metabolic profiling of fecal water, the profiling of complete fecal material remains under-explored. Here, a gas chromatography/time-of-flight mass spectrometry (GC/TOFMS) method was developed and validated for the global metabonomic profiling of human feces. Fecal and fecal water metabotypes were also profiled and compared. Additionally, the unclear influence of blood in stool on the fecal metabotype was investigated unprecedentedly. Eighty milligram of lyophilized feces was ultrasonicated with 1mL of methanol:water (8:2) for 30min, followed by centrifugation, drying of supernatant, oximation and trimethylsilylation for 45min. Lyophilized feces demonstrated a more comprehensive metabolic coverage than fecal water, based on the number of chromatographic peaks. Principal component analysis (PCA) indicated occult blood (1mgHb/g feces) exerted a negligible effect on the fecal metabotype. Conversely, a unique metabotype related to feces spiked with gross blood (100mgHb/g feces) was revealed (PCA, R(2)X=0.837, Q(2)=0.794), confirming the potential confounding effect of gross GIT bleeding on the fecal metabotype. This pertinent finding highlights the importance of prudent interpretation of fecal metabonomic data, particularly in GIT diseases where bleeding is prevalent. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Determining degree of roasting in cocoa beans by artificial neural network (ANN)-based electronic nose system and gas chromatography/mass spectrometry (GC/MS).

    PubMed

    Tan, Juzhong; Kerr, William L

    2018-08-01

    Roasting is a critical step in chocolate processing, where moisture content is decreased and unique flavors and texture are developed. The determination of the degree of roasting in cocoa beans is important to ensure the quality of chocolate. Determining the degree of roasting relies on human specialists or sophisticated chemical analyses that are inaccessible to small manufacturers and farmers. In this study, an electronic nose system was constructed consisting of an array of gas sensors and used to detect volatiles emanating from cocoa beans roasted for 0, 20, 30 and 40 min. The several signals were used to train a three-layer artificial neural network (ANN). Headspace samples were also analyzed by gas chromatography/mass spectrometry (GC/MS), with 23 select volatiles used to train a separate ANN. Both ANNs were used to predict the degree of roasting of cocoa beans. The electronic nose had a prediction accuracy of 94.4% using signals from sensors TGS 813, 826, 822, 830, 830, 2620, 2602 and 2610. In comparison, the GC/MS predicted the degree of roasting with an accuracy of 95.8%. The electronic nose system is able to predict the extent of roasting, as well as a more sophisticated approach using GC/MS. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  4. Quantitative Analysis of Bisphenol A Leached from Household Plastics by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry (SPME-GC-MS)

    ERIC Educational Resources Information Center

    Johnson, Bettie Obi; Burke, Fernanda M.; Harrison, Rebecca; Burdette, Samantha

    2012-01-01

    The measurement of trace levels of bisphenol A (BPA) leached out of household plastics using solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS) is reported here. BPA is an endocrine-disrupting compound used in the industrial manufacture of polycarbonate plastic bottles and epoxy resin can liners. This experiment…

  5. The "Metrica Regni" Project: The Polish Experience of EAD

    ERIC Educational Resources Information Center

    Wajs, Hubert

    2005-01-01

    The fonds of Crown Chancery Public Register ("Metrica Regni") was chosen for the pilot project to introduce Encoded Archival Description (EAD) because of its historical value, typical archival structure and existing finding aids. The rights and privileges granted by Polish kings were recorded in the Register. The oldest books in the…

  6. Assessment of a combined gas chromatography mass spectrometer sensor system for detecting biologically relevant volatile compounds.

    PubMed

    Gould, Oliver; Wieczorek, Tom; de Lacy Costello, Ben; Persad, Raj; Ratcliffe, Norman

    2017-12-06

    There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/SnO 2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These two different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. Twenty-nine chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but two instances the sensor exhibited the same or superior limit of detection compared to the MS. Twelve stool samples from healthy participants were analysed; the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly, analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications.

  7. Caisson disease during the construction of the Eads and Brooklyn Bridges: A review.

    PubMed

    Butler, W P

    2004-01-01

    The Eads Bridge (St. Louis) and the Brooklyn Bridge (New York City) were testing grounds for caisson construction. These caissons were enormous compressed air boxes used to build riverine piers and abutments anchoring the bridges. Caisson meant faster and cheaper construction, but there was a hidden cost---caisson disease (decompression sickness). Within caissons, workers labored at pressures as high as 55 psig and caisson disease was common. This discourse is a brief history of the caisson, a brief discussion of the illness as viewed in the mid 1800's, and an abbreviated history of the Eads and Brooklyn Bridges. It also provides a detailed description and evaluation of the observations, countermeasures, and recommendations of Dr. Alphonse Jaminet, the Eads Bridge physician, and Dr. Andrew Smith, the Brooklyn Bridge physician, who published reports of their experience in 1871 and 1873, respectively. These and other primary sources permit a detailed examination of early caisson disease and Jaminet's and Smith's thinking also serve as good examples from which to study and learn.

  8. Emission of Volatile Compounds from Apple Plants Infested with Pandemis heparana Larvae, Antennal Response of Conspecific Adults, and Preliminary Field Trial.

    PubMed

    Giacomuzzi, Valentino; Cappellin, Luca; Khomenko, Iuliia; Biasioli, Franco; Schütz, Stefan; Tasin, Marco; Knight, Alan L; Angeli, Sergio

    2016-12-01

    This study investigated the volatile emission from apple (Malus x domestica Borkh., cv. Golden Delicious) foliage that was either intact, mechanically-damaged, or exposed to larval feeding by Pandemis heparana (Denis and Schiffermüller) (Lepidoptera: Tortricidae). Volatiles were collected by closed-loop-stripping-analysis and characterized by gas chromatography-mass spectrometry in three time periods: after 1 h and again 24 and 48 h later. Volatiles for all treatments also were monitored continuously over a 72-h period by the use of proton transfer reaction - time of flight-mass spectrometry (PTR-ToF-MS). In addition, the volatile samples were analyzed by gas chromatography-electroantennographic detection (GC-EAD) using male and female antennae of P. heparana. Twelve compounds were detected from intact foliage compared with 23 from mechanically-damaged, and 30 from P. heparana-infested foliage. Interestingly, six compounds were released only by P. heparana-infested foliage. The emission dynamics of many compounds measured by PTR-ToF-MS showed striking differences according to the timing of herbivory and the circadian cycle. For example, the emission of green leaf volatiles began shortly after the start of herbivory, and increased over time independently from the light-dark cycle. Conversely, the emission of terpenes and aromatic compounds showed a several-hour delay in response to herbivory, and followed a diurnal rhythm. Methanol was the only identified volatile showing a nocturnal rhythm. Consistent GC-EAD responses were found for sixteen compounds, including five aromatic ones. A field trial in Sweden demonstrated that benzyl alcohol, 2-phenylethanol, phenylacetonitrile, and indole lures placed in traps were not attractive to Pandemis spp. adults, but 2-phenylethanol and phenylacetonitrile when used in combination with acetic acid were attractive to both sexes.

  9. Separation and screening of short-chain chlorinated paraffins in environmental samples using comprehensive two-dimensional gas chromatography with micro electron capture detection.

    PubMed

    Xia, Dan; Gao, Lirong; Zhu, Shuai; Zheng, Minghui

    2014-11-01

    Short-chain chlorinated paraffins (SCCPs) are highly complex technical mixtures with thousands of isomers and numerous homologs. They are classified as priority candidate persistent organic pollutants under the Stockholm Convention for their persistence, bioaccumulation, and toxicity. Analyzing SCCPs is challenging because of the complexity of the mixtures. Chromatograms of SCCPs acquired using one-dimensional (1D) gas chromatography (GC) contain a large characteristic "peak" with a broad and unresolved profile. Comprehensive two-dimensional GC (GC×GC) shows excellent potential for separating complex mixtures. In this study, GC×GC coupled with micro electron capture detection (μECD) was used to separate and screen SCCPs. The chromatographic parameters, including the GC column types, oven temperature program, and modulation period, were systematically optimized. The SCCP congeners were separated into groups using a DM-1 column connected to a BPX-50 column. The SCCP congeners in technical mixtures were separated according to the number of chlorine substituents for a given carbon chain length and according to the number of carbon atoms plus chlorine atoms for different carbon chain lengths. A fish tissue sample was analyzed to illustrate the feasibility of the GC×GC-μECD method in analyzing biological samples. Over 1,500 compounds were identified in the fish extract, significantly more than were identified using 1D GC. The detection limits for five selected SCCP congeners were between 1 and 5 pg/L using the GC×GC method, and these were significantly lower than those achieved using 1D GC. This method is a good choice for analysis of SCCPs in environmental samples, exhibiting good separation and good sensitivity.

  10. New designer drug p-methoxymethamphetamine: studies on its metabolism and toxicological detection in urine using gas chromatography-mass spectrometry.

    PubMed

    Staack, Roland F; Fehn, Josef; Maurer, Hans H

    2003-06-05

    Studies are described on the metabolism and the toxicological analysis of the new designer drug rac-p-methoxymethamphetamine (PMMA) in rat urine using gas chromatography-mass spectrometry (GC-MS). The identified metabolites indicated that PMMA was extensively metabolized mainly by O-demethylation to pholedrine and to a minor extent to p-methoxyamphetamine (PMA), 1-hydroxypholedrine diastereomers (one being oxilofrine), 4'-hydroxy-3'-methoxymethamphetamine and 4'-hydroxy-3'-methoxyamphetamine. The authors' systematic toxicological analysis (STA) procedure using full-scan GC-MS after acid hydrolysis, liquid-liquid extraction and microwave-assisted acetylation allowed the detection of the main metabolites of PMMA in rat urine after a dose corresponding to that of drug users. Therefore, this procedure should be suitable for detection of PMMA intake in human urine via its metabolites. However, it must be considered that pholedrine and oxilofrine are also in therapeutic use. Differentiation of PMMA, PMA and/or pholedrine intake is discussed.

  11. Detection and identification of drugs and toxicants in human body fluids by liquid chromatography-tandem mass spectrometry under data-dependent acquisition control and automated database search.

    PubMed

    Oberacher, Herbert; Schubert, Birthe; Libiseller, Kathrin; Schweissgut, Anna

    2013-04-03

    Systematic toxicological analysis (STA) is aimed at detecting and identifying all substances of toxicological relevance (i.e. drugs, drugs of abuse, poisons and/or their metabolites) in biological material. Particularly, gas chromatography-mass spectrometry (GC/MS) represents a competent and commonly applied screening and confirmation tool. Herein, we present an untargeted liquid chromatography-tandem mass spectrometry (LC/MS/MS) assay aimed to complement existing GC/MS screening for the detection and identification of drugs in blood, plasma and urine samples. Solid-phase extraction was accomplished on mixed-mode cartridges. LC was based on gradient elution in a miniaturized C18 column. High resolution electrospray ionization-MS/MS in positive ion mode with data-dependent acquisition control was used to generate tandem mass spectral information that enabled compound identification via automated library search in the "Wiley Registry of Tandem Mass Spectral Data, MSforID". Fitness of the developed LC/MS/MS method for application in STA in terms of selectivity, detection capability and reliability of identification (sensitivity/specificity) was demonstrated with blank samples, certified reference materials, proficiency test samples, and authentic casework samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Analysis of Alkaloids from Physalis peruviana by Capillary GC, Capillary GC-MS, and GC-FTIR.

    PubMed

    Kubwabo, C; Rollmann, B; Tilquin, B

    1993-04-01

    The alkaloid composition of the aerial parts and roots of PHYSALIS PERUVIANA was analysed by capillary GC (GC (2)), GC (2)-MS and GC (2)-FTIR. Eight alkaloids were identified, three of those alkaloids are 3beta-acetoxytropane and two N-methylpyrrolidinylhygrine isomers, which were not previously found in the genus PHYSALIS. A reproduction of the identification of alkaloids detected in the plant by the use of retention indices has been proposed.

  13. Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

    NASA Technical Reports Server (NTRS)

    Carle, G. C.

    1985-01-01

    Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

  14. Optimization of Supercomputer Use on EADS II System

    NASA Technical Reports Server (NTRS)

    Ahmed, Ardsher

    1998-01-01

    The main objective of this research was to optimize supercomputer use to achieve better throughput and utilization of supercomputers and to help facilitate the movement of non-supercomputing (inappropriate for supercomputer) codes to mid-range systems for better use of Government resources at Marshall Space Flight Center (MSFC). This work involved the survey of architectures available on EADS II and monitoring customer (user) applications running on a CRAY T90 system.

  15. ELECTRICAL AEROSOL DETECTOR (EAD) MEASUREMENTS AT THE ST. LOUIS SUPERSITE

    EPA Science Inventory

    The Model 3070A Electrical Aerosol Detector (EAD) measures a unique aerosol parameter called total aerosol length. Reported as mm/cm3, aerosol length can be thought of as a number concentration times average diameter, or simply as d1 weighting. This measurement falls between nu...

  16. EPA Method 525.3 - Determination of Semivolatile Organic Chemicals in Drinking Water by Solid Phase Extraction and Capillary Column Gas Chromatography/Mass Spectrometry (GC/MS)

    EPA Science Inventory

    Method 525.3 is an analytical method that uses solid phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) for the identification and quantitation of 125 selected semi-volatile organic chemicals in drinking water.

  17. Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.

    PubMed

    Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun

    2018-05-14

    To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.

  18. Separation and structural characterization of the new synthetic cannabinoid JWH-018 cyclohexyl methyl derivative "NE-CHMIMO" using flash chromatography, GC-MS, IR and NMR spectroscopy.

    PubMed

    Angerer, Verena; Bisel, Philippe; Moosmann, Bjoern; Westphal, Folker; Auwärter, Volker

    2016-09-01

    Synthetic cannabinoids have become an integral part of the drugs of abuse market since many years. The most frequent form of consumption for this class of substances is smoking of herbal mixtures purchased via the Internet. In this article the identification and structure elucidation of a new synthetic cannabinoid, [1-(cyclohexylmethyl)-1H-indol-3-yl](naphthalen-1-yl)methanone, is described. The compound was found along with 5F-ADB in a 'herbal mixture' called 'Jamaican Gold Extreme', which was sent to our laboratory in the context of a suspected intoxication. For isolation of the substance a flash chromatography separation was applied. Structure elucidation was performed using gas chromatography-mass spectrometry (GC-MS), gas chromatography solid-state infrared (GC-sIR) and nuclear magnetic resonance (NMR) analysis. The new compound can be described as the cyclohexyl methyl derivative of the first generation synthetic cannabinoid JWH-018, and the authors suggest to use "NE-CHMIMO" as a semisystematic name. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Detection and quantification of ochratoxin A and deoxynivalenol in barley grains by GC-MS and electronic nose.

    PubMed

    Olsson, J; Börjesson, T; Lundstedt, T; Schnürer, J

    2002-02-05

    Mycotoxin contamination of cereal grains can be detected and quantified using complex extraction procedures and analytical techniques. Normally, the grain odour, i.e. the presence of non-grain volatile metabolites, is used for quality classification of grain. We have investigated the possibility of using fungal volatile metabolites as indicators of mycotoxins in grain. Ten barley samples with normal odour, and 30 with some kind of off-odour were selected from Swedish granaries. The samples were evaluated with regard to moisture content, fungal contamination, ergosterol content, and levels of ochratoxin A (OA) and deoxynivalenol (DON). Volatile compounds were also analysed using both an electronic nose and gas chromatography combined with mass spectrometry (GC-MS). Samples with normal odour had no detectable ochratoxin A and average DON contents of 16 microg kg(-1) (range 0-80), while samples with off-odour had average OA contents of 76 microg kg(-1) (range 0-934) and DON contents of 69 microg kg(-1) (range 0-857). Data were evaluated by multivariate data analysis using projection methods such as principal component analysis (PCA) and partial least squares (PLS). The results show that it was possible to classify the OA level as below or above the maximum limit of 5 microg kg(-1) cereal grain established by the Swedish National Food Administration, and that the DON level could be estimated using PLS. Samples with OA levels below 5 microg kg(-1) had higher concentration of aldehydes (nonanal, 2-hexenal) and alcohols (1-penten-3-ol, 1-octanol). Samples with OA levels above 5 microg kg(-1) had higher concentrations of ketones (2-hexanone, 3-octanone). The GC-MS system predicted OA concentrations with a higher accuracy than the electronic nose, since the GC-MS misclassified only 3 of 37 samples and the electronic nose 7 of 37 samples. No correlation was found between odour and OA level, as samples with pronounced or strong off-odours had OA levels both below and above 5

  20. Metabolomics by Gas Chromatography-Mass Spectrometry: the combination of targeted and untargeted profiling

    PubMed Central

    Fiehn, Oliver

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS)-based metabolomics is ideal for identifying and quantitating small molecular metabolites (<650 daltons), including small acids, alcohols, hydroxyl acids, amino acids, sugars, fatty acids, sterols, catecholamines, drugs, and toxins, often using chemical derivatization to make these compounds volatile enough for gas chromatography. This unit shows that on GC-MS- based metabolomics easily allows integrating targeted assays for absolute quantification of specific metabolites with untargeted metabolomics to discover novel compounds. Complemented by database annotations using large spectral libraries and validated, standardized standard operating procedures, GC-MS can identify and semi-quantify over 200 compounds per study in human body fluids (e.g., plasma, urine or stool) samples. Deconvolution software enables detection of more than 300 additional unidentified signals that can be annotated through accurate mass instruments with appropriate data processing workflows, similar to liquid chromatography-MS untargeted profiling (LC-MS). Hence, GC-MS is a mature technology that not only uses classic detectors (‘quadrupole’) but also target mass spectrometers (‘triple quadrupole’) and accurate mass instruments (‘quadrupole-time of flight’). This unit covers the following aspects of GC-MS-based metabolomics: (i) sample preparation from mammalian samples, (ii) acquisition of data, (iii) quality control, and (iv) data processing. PMID:27038389

  1. TagFinder for the quantitative analysis of gas chromatography--mass spectrometry (GC-MS)-based metabolite profiling experiments.

    PubMed

    Luedemann, Alexander; Strassburg, Katrin; Erban, Alexander; Kopka, Joachim

    2008-03-01

    Typical GC-MS-based metabolite profiling experiments may comprise hundreds of chromatogram files, which each contain up to 1000 mass spectral tags (MSTs). MSTs are the characteristic patterns of approximately 25-250 fragment ions and respective isotopomers, which are generated after gas chromatography (GC) by electron impact ionization (EI) of the separated chemical molecules. These fragment ions are subsequently detected by time-of-flight (TOF) mass spectrometry (MS). MSTs of profiling experiments are typically reported as a list of ions, which are characterized by mass, chromatographic retention index (RI) or retention time (RT), and arbitrary abundance. The first two parameters allow the identification, the later the quantification of the represented chemical compounds. Many software tools have been reported for the pre-processing, the so-called curve resolution and deconvolution, of GC-(EI-TOF)-MS files. Pre-processing tools generate numerical data matrices, which contain all aligned MSTs and samples of an experiment. This process, however, is error prone mainly due to (i) the imprecise RI or RT alignment of MSTs and (ii) the high complexity of biological samples. This complexity causes co-elution of compounds and as a consequence non-selective, in other words impure MSTs. The selection and validation of optimal fragment ions for the specific and selective quantification of simultaneously eluting compounds is, therefore, mandatory. Currently validation is performed in most laboratories under human supervision. So far no software tool supports the non-targeted and user-independent quality assessment of the data matrices prior to statistical analysis. TagFinder may fill this gap. TagFinder facilitates the analysis of all fragment ions, which are observed in GC-(EI-TOF)-MS profiling experiments. The non-targeted approach allows the discovery of novel and unexpected compounds. In addition, mass isotopomer resolution is maintained by TagFinder processing. This

  2. [Detection of methyl carbamate and ethyl carbamate in yellow rice wine by gas chromatography-mass spectrometry].

    PubMed

    Wu, Ping-gu; Ma, Bing-jie; Wang, Li-yuan; Shen, Xiang-hong; Zhang, Jing; Tan, Ying; Jiang, Wei

    2013-11-01

    To establish the method of simultaneous determination of methylcarbamate (MC) and ethylcarbamate (EC) in yellow rice wine by gas chromatography-mass spectrometry (GC/MS). MC and EC in yellow rice wine were derived by 9-xanthydrol, and then the derivants were detected by GC/MS; and quantitatively analyzed by D5-EC isotope internal standard method. The linearity of MC and EC ranged from 2.0 µg/L to 400.0 µg/L, with correlation coefficients at 0.998 and 0.999, respectively. The limits of quantitation (LOQ) and detection (LOD) were 0.67 and 2.0 µg/kg. When MC and EC were added in yellow rice wine at the range of 2.0-300.0 µg/kg, the intraday average recovery rate was 78.8%-102.3%, relative standard deviation was 3.2%-11.6%; interday average recovery rate was 75.4%-101.3%, relative standard deviation was 3.8%-13.4%. 20 samples of yellow rice wine from supermarket were detected using this method, the contents of MC were in the range of ND (no detected) to 1.2 µg/kg, the detection rate was 6% (3/20), the contents of EC in the range of 18.6 µg/kg to 432.3 µg/kg, with the average level at 135.2 µg/kg. The method is simple, rapid and useful for simultaneous determination of MC and EC in yellow rice wine.

  3. Quantification of 11-Carboxy-Delta-9-Tetrahydrocannabinol (THC-COOH) in Meconium Using Gas Chromatography/Mass Spectrometry (GC/MS).

    PubMed

    Peat, Judy; Davis, Brehon; Frazee, Clint; Garg, Uttam

    2016-01-01

    Maternal substance abuse is an ongoing concern and detecting drug use during pregnancy is an important component of neonatal care when drug abuse is suspected. Meconium is the preferred specimen for drug testing because it is easier to collect than neonatal urine and it provides a much broader time frame of drug exposure. We describe a method for quantifying 11-carboxy-delta-9-tetrahydrocannabinol (THC-COOH) in meconium. After adding a labeled internal standard (THC-COOH D9) and acetonitrile, samples are sonicated to release both free and conjugated THC-COOH. The acetonitrile/aqueous layer is removed and mixed with a strong base to hydrolyze the conjugated THC-COOH. The samples are then extracted with an organic solvent mixture as part of a sample "cleanup." The organic solvent layer is discarded and the remaining aqueous sample is acidified. Following extraction with a second organic mixture, the organic layer is removed and concentrated to dryness. The resulting residue is converted to a trimethylsilyl (TMS) derivative and analyzed using gas chromatography/mass spectrometry (GC/MS) in selective ion monitoring (SIM) mode.

  4. Advances in field-portable ion trap GC/MS instrumentation

    NASA Astrophysics Data System (ADS)

    Diken, Eric G.; Arno, Josep; Skvorc, Ed; Manning, David; Andersson, Greger; Judge, Kevin; Fredeen, Ken; Sadowski, Charles; Oliphant, Joseph L.; Lammert, Stephen A.; Jones, Jeffrey L.; Waite, Randall W.; Grant, Chad; Lee, Edgar D.

    2012-06-01

    The rapid and accurate detection and identification of chemical warfare agents and toxic industrial chemicals can be critical to the protection of military and civilian personnel. The use of gas chromatography (GC) - mass spectrometry (MS) can provide both the sensitivity and selectivity required to identify unknown chemicals in complex (i.e. real-world) environments. While most widely used as a laboratory-based technique, recent advances in GC, MS, and sampling technologies have led to the development of a hand-portable GC/MS system that is more practical for field-based analyses. The unique toroidal ion trap mass spectrometer (TMS) used in this instrument has multiple benefits related to size, weight, start-up time, ruggedness, and power consumption. Sample separation is achieved in record time (~ 3 minutes) and with high resolution using a state-of-the-art high-performance low-thermal-mass GC column. In addition to providing a system overview highlighting its most important features, the presentation will focus on the chromatographic and mass spectral performance of the system. Results from exhaustive performance testing of the new instrument will be introduced to validate its unique robustness and ability to identify targeted and unknown chemicals.

  5. Guilty by dissociation-development of gas chromatography-mass spectrometry (GC-MS) and other rapid screening methods for the analysis of 13 diphenidine-derived new psychoactive substances (NPSs).

    PubMed

    Geyer, Pierre M; Hulme, Matthew C; Irving, Joseph P B; Thompson, Paul D; Ashton, Ryan N; Lee, Robert J; Johnson, Lucy; Marron, Jack; Banks, Craig E; Sutcliffe, Oliver B

    2016-11-01

    The prevalence of new psychoactive substances (NPSs) in forensic casework has increased prominently in recent years. This has given rise to significant legal and analytical challenges in the identification of these substances. The requirement for validated, robust and rapid testing methodologies for these compounds is obvious. This study details the analysis of 13 synthesised diphenidine derivatives encountered in casework using presumptive testing, thin layer chromatography and gas chromatography-mass spectrometry (GC-MS). Specifically, the validated GC-MS method provides, for the first time, both a general screening method and quantification of the active components for seized solid samples, both in their pure form and in the presence of common adulterants. Graphical Abstract Chemical synthesis and forensic analysis of 13 diphenidine-derived new psychoactive substance(s).

  6. A major host plant volatile, 1-octen-3-ol, contributes to mating in the legume pod borer, Maruca vitrata (Fabricius) (Lepidoptera: Crambidae)

    NASA Astrophysics Data System (ADS)

    Bendera, M.; Ekesi, S.; Ndung'u, M.; Srinivasan, R.; Torto, B.

    2015-10-01

    Previous studies on the legume pod borer, Maruca vitrata Fabricius (Lepidoptera: Crambidae), a serious pest of cowpea, Vigna unguiculata (L.) Walp. (Fabales: Fabaceae), in sub-Saharan Africa have focused on sex pheromones, but the role of the host plant on sexual behavior has not been explored. We investigated this interaction in the laboratory using behavioral assays and chemical analyses. We found that the presence of cowpea seedlings and a dichloromethane extract of the leaf increased coupling in the legume pod borer by 33 and 61 %, respectively, compared to the control, suggesting the involvement of both contact and olfactory cues. We used coupled gas chromatography-electroantennographic detection (GC/EAD) and GC-mass spectrometry (GC/MS) to identify compounds from the cowpea leaf extract, detected by M. vitrata antenna. We found that the antennae of the insect consistently detected four components, with 1-octen-3-ol identified as a common and dominant component in both the volatiles released by the intact cowpea plant and leaf extract. We therefore investigated its role in the coupling of M. vitrata. In dose-response assays, 1-octen-3-ol increased coupling in M. vitrata with increasing dose of the compound compared to the control. Our results suggest that the cowpea volatile 1-octen-3-ol contributes to M. vitrata sexual behavior.

  7. Disentangling oil weathering using GC x GC. 1. chromatogram analysis.

    PubMed

    Arey, J Samuel; Nelson, Robert K; Reddy, Christopher M

    2007-08-15

    Historically, the thousands of compounds found in oils constituted an "unresolved complex mixture" that frustrated efforts to analyze oil weathering. Moreover, different weathering processes inflict rich and diverse signatures of compositional change in oil, and conventional methods do not effectively decode this elaborate record. Using comprehensive two-dimensional gas chromatography (GC x GC), we can separate thousands of hydrocarbon components and simultaneously estimate their chemical properties. We investigated 13 weathered field samples collected from the Bouchard 120 heavy fuel oil spill in Buzzards Bay, Massachusetts in 2003. We first mapped hydrocarbon vapor pressures and aqueous solubilities onto the compositional space explored by GC x GC chromatograms of weathered samples. Then we developed methods to quantitatively decouple mass loss patterns associated with evaporation and dissolution. The compositional complexity of oil, traditionally considered an obstacle, was now an advantage. We exploited the large inventory of chemical information encoded in oil to robustly differentiate signatures of mass transfer to air and water. With this new approach, we can evaluate mass transfer models (the Part 2 companion to this paper) and more properly account for evaporation, dissolution, and degradation of oil in the environment.

  8. Simultaneous Determination of Benzene and Toluene in Pesticide Emulsifiable Concentrate by Headspace GC-MS

    PubMed Central

    Jiang, Hua; Yang, Jing; Fan, Li; Li, Fengmin; Huang, Qiliang

    2013-01-01

    The toxic inert ingredients in pesticide formulations are strictly regulated in many countries. In this paper, a simple and efficient headspace-gas chromatography-mass spectrometry (HSGC-MS) method using fluorobenzene as an internal standard (IS) for rapid simultaneous determination of benzene and toluene in pesticide emulsifiable concentrate (EC) was established. The headspace and GC-MS conditions were investigated and developed. A nonpolar fused silica Rtx-5 capillary column (30 m × 0.20 mm i.d. and 0.25 μm film thickness) with temperature programming was used. Under optimized headspace conditions, equilibration temperature of 120°C, equilibration time of 5 min, and sample size of 50 μL, the regression of the peak area ratios of benzene and toluene to IS on the concentrations of analytes fitted a linear relationship well at the concentration levels ranging from 3.2 g/L to 16.0 g/L. Standard additions of benzene and toluene to blank different matrix solutions 1ead to recoveries of 100.1%–109.5% with a relative standard deviation (RSD) of 0.3%–8.1%. The method presented here stands out as simple and easily applicable, which provides a way for the determination of toxic volatile adjuvant in liquid pesticide formulations. PMID:23607048

  9. Enhanced Characterization of the Smell of Death by Comprehensive Two-Dimensional Gas Chromatography-Time-of-Flight Mass Spectrometry (GCxGC-TOFMS)

    PubMed Central

    Dekeirsschieter, Jessica; Stefanuto, Pierre-Hugues; Brasseur, Catherine; Haubruge, Eric; Focant, Jean-François

    2012-01-01

    Soon after death, the decay process of mammalian soft tissues begins and leads to the release of cadaveric volatile compounds in the surrounding environment. The study of postmortem decomposition products is an emerging field of study in forensic science. However, a better knowledge of the smell of death and its volatile constituents may have many applications in forensic sciences. Domestic pigs are the most widely used human body analogues in forensic experiments, mainly due to ethical restrictions. Indeed, decomposition trials on human corpses are restricted in many countries worldwide. This article reports on the use of comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GCxGC-TOFMS) for thanatochemistry applications. A total of 832 VOCs released by a decaying pig carcass in terrestrial ecosystem, i.e. a forest biotope, were identified by GCxGC-TOFMS. These postmortem compounds belong to many kinds of chemical class, mainly oxygen compounds (alcohols, acids, ketones, aldehydes, esters), sulfur and nitrogen compounds, aromatic compounds such as phenolic molecules and hydrocarbons. The use of GCxGC-TOFMS in study of postmortem volatile compounds instead of conventional GC-MS was successful. PMID:22723918

  10. Improved Thermal Modulator for Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  11. Behavioral and electroantennogram responses of plum curculio, Conotrachelus nenuphar, to selected noxious plant extracts and insecticides.

    PubMed

    Gӧkçe, A; Stelinski, L L; Nortman, D R; Bryan, W W; Whalon, M E

    2014-01-01

    Behavioral and electroantennogram responses of plum curculio, Conotrachelus nenuphar (Herbst) (Coleoptera: Curculionidae), adults were tested for several methanolic plant extracts and organically approved insecticides. Plant extracts were evaluated for their potential as antifeedants or oviposition deterrents. These extract responses were also compared to those elicited by the non-neurotoxic, organic irritant-insecticide kaolin clay. Both sexes of plum curculio exhibited antennal response as measured by electroantennogram, which ranged from 0.2 to 1.1 mV, to plant extracts and the organic irritant/insecticide, with the greatest response to the extract of rough cocklebur, Xanthium strumarium L. (1.1 mV). No choice tests were conducted to compare feeding and oviposition by plum curculio on untreated apples or on apples treated with one of the extracts or the insecticide. The insecticide pyrethrum and extracts of X. strumarium and greater burdock, Arctium lappa L., significantly reduced feeding. Also, pyrethrum, A. lappa, Humulus lupulus L. (common hop), X. strumarium, and Verbascum songaricum Schrenk extracts completely inhibited egg deposition. In no-choice assays, the effects of kaolin clay with incorporated plant extracts on plum curculio feeding and oviposition were monitored as complementary tests. A. lappa-kaolin, H. lupulus-kaolin, and X. strumarium-kaolin mixtures significantly reduced the feeding of plum curculio compared to the control or kaolin clay alone. Each of the plant extract-kaolin mixtures evaluated, with the exception of Bifora radians Bieberstein (wild bishop), completely inhibited plum curculio oviposition as compared to controls. This is an open access paper. We use the Creative Commons Attribution 3.0 license that permits unrestricted use, provided that the paper is properly attributed.

  12. Classification of organic aerosol in the atmosphere over Seoul based on chemical group separation using two dimensional gas chromatography-time of flight mass spectrometry (GC×GC TOFMS) data

    NASA Astrophysics Data System (ADS)

    Jeon, S.; Lim, H. B.; Choi, N.; Lee, J.; Ahn, Y. K.; Kim, Y. P.

    2016-12-01

    Organic aerosols contain thousands of organic compounds and contribute to 20-90% of the total fine aerosol mass. For analyzing organic aerosols, a wide range of analytical techniques have been used such as gas chromatography mass spectrometer (GC/MS), liquid chromatography mass spectrometer (LC/MS), aerosol mass spectrometer (AMS), etc. Among them, comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometer (GCxGC/TOF-MS) can provide higher chemical resolution than AMS and analyze more mass fractions of organic aerosols than GC/MS. In this study, we suggest a new data processing method using GCxGC/TOF-MS data for analyzing organic compounds in the ambient aerosols. TSP samples were collected on the roof of the Asan engineering building, Ewha Womans University, Seoul, South Korea (37.56 °N, 126.94 °E, 20 m above ground level). A total of 67 samples were obtained during summer (August 2013) and winter (January and February 2014) with a PUF sampler (Tisch, TE-1000) on quartz fiber filter. Filters were extracted using accelerated solvent extractor with a mixture of dichloromethane and methanol (3:1, v/v). Total extracts were blown down to 0.5 mL using a nitrogen evaporator (Turbo Vap Ⅱ, caliper Life Sciences). Organic compounds in the TSP samples were separated into 6 chemical groups, depending on their retention time in two dimensions for their volatility and polarity. All area of peaks in each group was summed and variance of total area in each group was compared depending on season and diurnal cycle.

  13. Preparation of a novel hyperbranched carbosilane-silica hybrid coating for trace amount detection by solid phase microextraction/gas chromatography.

    PubMed

    Chen, Guowen; Li, Wenjie; Zhang, Chen; Zhou, Chuanjian; Feng, Shengyu

    2012-09-21

    Phenyl-ended hyperbranched carbosilane (HBC) is synthesized and immobilized onto the inner wall of a fused silica capillary column using a sol-gel process. The hybrid coating layer formed is used as a stationary phase for gas chromatography (GC) and as an adsorption medium for solid phase microextraction (SPME). Trifluoroacetic acid, as a catalyst in this process, helps produce a homogeneous hybrid coating layer. This result is beneficial for better column chromatographic performances, such as high efficiency and high resolution. Extraction tests using the novel hybrid layer show an extraordinarily large adsorption capacity and specific adsorption behavior for aromatic compounds. A 1 ppm trace level detectability is obtained with the SPME/GC work model when both of the stationary phase and adsorption layer bear a hyperbranched structure. A large amount of phenyl groups and a low viscosity of hyperbranched polymers contribute to these valuable properties, which are important to environment and safety control, wherein detection sensitivity and special adsorption behavior are usually required. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Genuineness assessment of mandarin essential oils employing gas chromatography-combustion-isotope ratio MS (GC-C-IRMS).

    PubMed

    Schipilliti, Luisa; Tranchida, Peter Quinto; Sciarrone, Danilo; Russo, Marina; Dugo, Paola; Dugo, Giovanni; Mondello, Luigi

    2010-03-01

    Cold-pressed mandarin essential oils are products of great economic importance in many parts of the world and are used in perfumery, as well as in food products. Reconstituted mandarin oils are easy to find on the market; useful information on essential oil authenticity, quality, extraction technique, geographic origin and biogenesis can be attained through high-resolution GC of the volatile fraction, or enantioselective GC, using different chiral stationary phases. Stable isotope ratio analysis has gained considerable interest for the unveiling of citrus oil adulteration, detecting small differences in the isotopic carbon composition and providing plenty of information concerning the discrimination among products of different geographical origin and the adulteration of natural essential oils with synthetic or natural compounds. In the present research, the authenticity of several mandarin essential oils was assessed through the employment of GC hyphenated to isotope ratio MS, conventional GC flame ionization detector, enantioselective GC and HPLC. Commercial mandarin oils and industrial natural (declared as such) mandarin essential oils, characterized by different harvest periods and geographic origins, were subjected to analysis. The results attained were compared with those of genuine cold-pressed Italian mandarin oils, obtained during the 2008-2009 harvest season.

  15. GC/MS Analysis of the Essential Oil of Vernonia cinerea.

    PubMed

    Joshi, Rajesh K

    2015-07-01

    The hydro-distilled essential oil obtained from the roots of V. cinerea Less. (Asteraceae) was investigated by gas chromatography equipped with flame ionization detector (GC-FID) and gas chromatography coupled with mass spectrometry (GC/MS). Twenty-five constituents were identified, which represented 97.4% of the total oil. The major compounds were α-muurolene (30.7%), β-caryophyllene (9.6%), α-selinene (8.7%), cyperene (6.7%) and α-gurjunene (6.5%). The essential oil was dominated by sesquiterpene hydrocarbons (87.8%).

  16. Ultratrace detector for hand-held gas chromatography

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    1999-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and C0.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  17. [Simultaneous determination of cocaine and its metabolite ecgonine methyl ester in human blood using microwave extraction-gas chromatography].

    PubMed

    Wang, Xiaobo; Ye, Nengsheng; Wang, Jifen; Gu, Xuexin

    2010-07-01

    A method was developed for the simultaneous determination of cocaine (COC) and its metabolite ecgonine methyl ester (EME) in human blood using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-flame ionization detection (GC-FID). The blood sample was prepared by microwave extraction (MWE). The optimal parameters of MWE were as follows: 6 mL of chloroform-isopropanol (9: 1, v/v) mixture as extraction solvent, the pH value of the sample was adjusted at 10.0 with 0.05 mol/L Na2CO3-NaHCO3 buffer, the extraction was performed at 40 degrees C for 6 min. The COC and EME in the extract were qualified using GC-MS and quantitated using GC-FID. The average recoveries of COC and EME were from 79.91% to 99.85%, the relative standard deviations were less than 3.10%, and the limits of detection (LOD) were 60 and 40 mg/L, respectively. In the method COC and EME were detected without derivatization. The method is rapid, accurate and sensitive, and can be used for the simultaneous determination of COC and EME in blood samples.

  18. Enantioselective determination of the organochlorine pesticide bromocyclen in spiked fish tissue using solid-phase microextraction coupled to gas chromatography with ECD and ICP-MS detection.

    PubMed

    Fidalgo-Used, Natalia; Montes-Bayón, Maria; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2008-05-15

    A method for enantioselective determination of bromocyclen enantiomers in fish tissue has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (CP-Chirasil-Dex CB) and a temperature program from 50 degrees C (held for 1 min), raised to 140 degrees C at 40 degrees C min(-1) and then raised at 0.2 degrees C min(-1) to 155 degrees C. This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on solid-phase microextraction (SPME). Under SPME optimized conditions, precision, linearity range and detection limits of the developed SPME-enantioselective GC procedure were evaluated and compared using two different detection systems: a classical electron-capture detection (ECD) and an element specific detection using inductively coupled plasma mass spectrometry (ICP-MS). The SPME-GC-ECD method exhibited an excellent sensitivity, with detection limits of 0.2 ng L(-1) for each enantiomer of bromocyclen. Although ICP-MS offered poorer detection limits (7 ng L(-1) as Br, equivalent to 36 ng L(-1) of each enantiomer) than conventional ECD detector, it proved to be clearly superior in terms of selectivity. The relative potential and performance of the two compared methods for real-life analysis has been illustrated by the determination of enantiomers of bromocyclen in spiked tissue extracts of trout.

  19. Selecting odorant compounds to enhance sweet flavor perception by gas chromatography/olfactometry-associated taste (GC/O-AT).

    PubMed

    Barba, Carmen; Beno, Noelle; Guichard, Elisabeth; Thomas-Danguin, Thierry

    2018-08-15

    Gas chromatography/olfactometry-associated taste (GC/O-AT) analysis combined with mass spectrometry allowed identification of odorant compounds associated with taste attributes (sweet, salty, bitter and sour) in a multi-fruit juice. Nine compounds were selected for their odor-associated sweetness enhancement in a multi-fruit juice odor context using Olfactoscan and for their odor-induced sweet taste enhancement in sucrose solution and sugar-reduced fruit juice through sensory tests. Sweetness of the fruit juice odor was significantly enhanced by methyl 2-methylbutanoate, ethyl butanoate, ethyl 2-methylbutanoate and linalool; sweet perception was significantly enhanced in 7% sucrose solution by ethyl 2-methylbutanoate, furaneol and γ-decalactone, and in 32% sugar-reduced fruit juice by ethyl 2-methylbutanoate. GC/O-AT analysis is a novel, efficient approach to select odorants associated with a given taste. The further screening of taste-associated odorants by Olfactoscan helps to identify the most efficient odorants to enhance a target taste perception and may be used to find new ways to modulate taste perception in foods and beverages. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mule, S.J.; Lomax, P.; Gross, S.J.

    Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.

  1. Bisphenol A release from an orthodontic resin composite: A GC/MS and LC/MS study.

    PubMed

    Deviot, Marc; Lachaise, Isabelle; Högg, Christof; Durner, Jürgen; Reichl, Franz-Xaver; Attal, Jean-Pierre; Dursun, Elisabeth

    2018-02-01

    First, to analyse the in vitro release of BPA and Bis-GMA from an orthodontic resin composite (Transbond XT, 3M Unitek), stored in various conditions, by gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS); then to extrapolate the data to the clinical situation. Secondly, to explore the thermal stability of Bis-GMA. Cylinders of resin composite were prepared and stored according to 3 different protocols: (1) they were light-cured 20s, then placed in artificial saliva; (2) they were light-cured 2s, then placed in acetonitrile; (3) they were light-cured 2s, then placed in methanol. For each group, BPA and Bis-GMA release were determined with GC/MS and/or LC/MS at least after one week. Besides, 120 brackets (10 of each type) were bonded over metal teeth, then debonded, and the weight and the surface of resin composite residues were measured. BPA and Bis-GMA release of adhesive residues were extrapolated from the data obtained with the cylinders. Besides, BPA release from a heated Bis-GMA solution was measured. With GC/MC, BPA was detected in all samples. With LC/MS, BPA was detected only from samples immersed in MeOH; Bis-GMA was detected, in varying amount according to the extraction media and the light-curing time. BPA was found after heating of the Bis-GMA solution. Contamination risk and the heat applied in GC/MS may overestimate the BPA release from resin composite. Based on the LC/MS results, the risk of BPA release after orthodontic bonding would be more than 42000 times lower than the TDI for a 30-kg child. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Utilizing two detectors in the measurement of trichloroacetic acid in human urine by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-05-16

    A reaction headspace gas chromatography (HS-GC) technique was investigated for quantitatively analyzing trichloroacetic acid in human urine. This method is based on the decomposition reaction of trichloroacetic acid under high-temperature conditions. The carbon dioxide and chloroform formed from the decomposition reaction can be respectively detected by the thermal conductivity detection HS-GC and flame ionization detection HS-GC. The reaction can be completed in 60 min at 90°C. This method was used to quantify 25 different human urine samples, which had a range of trichloroacetic acid from 0.52 to 3.47 mg/L. It also utilized two different detectors, the thermal conductivity detector and the flame ionization detector. The present reaction HS-GC method is accurate, reliable and well suitable for batch detection of trichloroacetic acid in human urine. Copyright © 2018 John Wiley & Sons, Ltd.

  3. Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C.J. Miller; G. Elias; N.C. Schmitt

    2010-06-01

    High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that weremore » used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.« less

  4. Identification of aroma-active volatiles in banana Terra spirit using multidimensional gas chromatography with simultaneous mass spectrometry and olfactometry detection.

    PubMed

    Capobiango, Michely; Mastello, Raíssa Bittar; Chin, Sung-Tong; Oliveira, Evelyn de Souza; Cardeal, Zenilda de Lourdes; Marriott, Philip John

    2015-04-03

    Fruit spirits have been produced and consumed throughout the world for centuries. However, the aroma composition of banana spirits is still poorly characterised. We have investigated the aroma-impact compounds of the banana Terra spirit for the first time, using multidimensional gas chromatography (MDGC and GC × GC) in a multi-hyphenated system - i.e., coupled to flame ionisation detection (FID), mass spectrometry (MS), and olfactometry (O). Solid-phase microextraction (SPME) was used to isolate the headspace aroma compounds of the banana spirit. The detection frequency (DF) technique was applied and aroma regions, detected in the first column separation at >60% Nasal Impact Frequency (NIF), were screened as target potent odour regions in the sample. Using a polar/non-polar phase column set, the potent odour regions were further subjected to MDGC separation with simultaneous O and MS detection for correlation of the aroma perception with MS data for individual resolved aroma-impact compounds. GC-O analysis enabled 18 aroma-impact regions to be located as providing volatiles of interest for further study; for example, those comprising perceptions of flower, whisky, green, amongst others. Compounds were tentatively identified through MS data matching and retention indices in both first and second dimensions. The principal volatile compounds identified in this work, which are responsible for the characteristic aroma of the banana spirit, are 3-methylbutan-1-ol, 3-methylbutan-1-ol acetate, 2-phenylethyl acetate and phenylethyl alcohol. This is the first such study to reveal the major aroma compounds that contribute to banana spirit aroma. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    PubMed

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Determination of volatile nitrosamines in grilled lamb and vegetables using comprehensive gas chromatography - nitrogen chemiluminescence detection.

    PubMed

    Kocak, D; Ozel, M Z; Gogus, F; Hamilton, J F; Lewis, A C

    2012-12-15

    The grilling of meat may generate dangerous levels of mutagenic and carcinogenic nitrosamines (NAs). Meat and vegetable samples underwent a two-step solid-phase extraction before analysis by comprehensive gas chromatography with a nitrogen chemiluminescence detection system (GCxGC-NCD). The GCxGC-NCD method showed high selectivity, sensitivity and equimolarity in its response to six specific NAs. NA contamination of charcoal-grilled lamb at various stages of cooking and with various fat contents and also charcoal-grilled vegetables were investigated. The grilling of lamb on unready charcoal resulted in the formation of considerable quantities of NAs. Grilling lamb on properly prepared, ready charcoal resulted in an increase in total concentrations of six NAs from 0 to 4.51 μg kg(-1) over a period of 16 min. Increasing the fat content of the grilled lamb from 5% to 20% caused a modest increase in total concentrations of the six investigated NAs from 4.51 to 5.30 μg kg(-1). Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PESTICIDE SAMPLES BY GC/ECD (BCO-L-24.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography electron capture detector (GC/ECD) of pesticides in a variety of matrices, including air, house dust, soil, handwipes, and surface wipes. Other SOP's detail the extract...

  8. Methanol ice VUV photoprocessing: GC-MS analysis of volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Abou Mrad, Ninette; Duvernay, Fabrice; Chiavassa, Thierry; Danger, Grégoire

    2016-05-01

    Next to water, methanol is one of the most abundant molecules in astrophysical ices. A new experimental approach is presented here for the direct monitoring via gas chromatography coupled to mass spectrometry (GC-MS) of a sublimating photoprocessed pure methanol ice. Unprecedentedly, in a same analysis, compelling evidences for the formation of 33 volatile organic compounds are provided. The latter are C1-C6 products including alcohols, aldehydes, ketones, esters, ethers and carboxylic acids. Few C3 and all C4 detected compounds have been identified for the first time. Tentative detections of few C5 and C6 compounds are also presented. GC-MS allows for the first time the direct quantification of C2-C4 photoproducts and shows that their abundances decrease with the increase of their carbon chain length. These qualitative and quantitative measurements provide important complementary results to previous experiments, and present interesting similarities with observations of sources rich in methanol.

  9. Antidepressants detection and quantification in whole blood samples by GC-MS/MS, for forensic purposes.

    PubMed

    Truta, Liliana; Castro, André L; Tarelho, Sónia; Costa, Pedro; Sales, M Goreti F; Teixeira, Helena M

    2016-09-05

    Depression is among the most prevalent psychiatric disorders of our society, leading to an increase in antidepressant drug consumption that needs to be accurately determined in whole blood samples in Forensic Toxicology Laboratories. For this purpose, this work presents a new gas chromatography tandem mass spectrometry (GC-MS/MS) method targeting the simultaneous and rapid determination of 14 common Antidepressants in whole blood: 13 Antidepressants (amitriptyline, citalopram, clomipramine, dothiepin, fluoxetine, imipramine, mianserin, mirtazapine, nortryptiline, paroxetine, sertraline, trimipramine and venlafaxine) and 1 Metabolite (N-desmethylclomipramine). Solid-phase extraction was used prior to chromatographic separation. Chromatographic and MS/MS parameters were selected to improve sensitivity, peak resolution and unequivocal identification of the eluted analyte. The detection was performed on a triple quadrupole tandem MS in selected ion monitoring (SIM) mode in tandem, using electronic impact ionization. Clomipramine-D3 and trimipramine-D3 were used as deutered internal standards. The validation parameters included linearity, limits of detection, lower limit of quantification, selectivity/specificity, extraction efficiency, carry-over, precision and robustness, and followed internationally accepted guidelines. Limits of quantification and detection were lower than therapeutic and sub-therapeutic concentration ranges. Overall, the method offered good selectivity, robustness and quick response (<16min) for typical concentration ranges, both for therapeutic and lethal levels. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Low-Level detections of halogenated volatile organic compounds in groundwater: Use in vulnerability assessments

    USGS Publications Warehouse

    Plummer, Niel; Busenberg, E.; Eberts, S.M.; Bexfield, L.M.; Brown, C.J.; Fahlquist, L.S.; Katz, B.G.; Landon, M.K.

    2008-01-01

    Concentrations of halogenated volatile organic compounds (VOCs) were determined by gas chromatography (GC) with an electron-capture detector (GC-ECD) and by gas chromatography with mass spectrometry (GC-MS) in 109 groundwater samples from five study areas in the United States. In each case, the untreated water sample was used for drinking-water purposes or was from a monitoring well in an area near a drinking-water source. The minimum detection levels (MDLs) for 25 VOCs that were identified in GC-ECD chromatograms, typically, were two to more than four orders of magnitude below the GC-MS MDLs. At least six halogenated VOCs were detected in all of the water samples analyzed by GC-ECD, although one or more VOCs were detected in only 43% of the water samples analyzed by GC-MS. In nearly all of the samples, VOC concentrations were very low and presented no known health risk. Most of the low-level VOC detections indicated post-1940s recharge, or mixtures of recharge that contained a fraction of post-1940s water. Concentrations of selected halogenated VOCs in groundwater from natural and anthropogenic atmospheric sources were estimated and used to recognize water samples that are being impacted by nonatmospheric sources. A classification is presented to perform vulnerability assessments at the scale of individual wells using the number of halogenated VOC detections and total dissolved VOC concentrations in samples of untreated drinking water. The low-level VOC detections are useful in vulnerability assessments, particularly for samples in which no VOCs are detected by GC-MS analysis.

  11. Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Glavin, D. P.; Buch, A.; Mahaffy, P. R.

    2004-01-01

    One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds

  12. ENVIRONMENTAL ANALYSIS BY AB INITIO QUANTUM MECHANICAL COMPUTATION AND GAS CHROMATOGRAPHY/FOURIER TRANSFORM INFRARED SPECTROMETRY.

    EPA Science Inventory

    Computational chemistry, in conjunction with gas chromatography/mass spectrometry/Fourier transform infrared spectrometry (GC/MS/FT-IR), was used to tentatively identify seven tetrachlorobutadiene (TCBD) isomers detected in an environmental sample. Computation of the TCBD infrare...

  13. Determination of different recreational drugs in sweat by headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME GC/MS): Application to drugged drivers.

    PubMed

    Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona

    2016-09-10

    A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Application of gas chromatography/flame ionization detector-based metabolite fingerprinting for authentication of Asian palm civet coffee (Kopi Luwak).

    PubMed

    Jumhawan, Udi; Putri, Sastia Prama; Yusianto; Bamba, Takeshi; Fukusaki, Eiichiro

    2015-11-01

    Development of authenticity screening for Asian palm civet coffee, the world-renowned priciest coffee, was previously reported using metabolite profiling through gas chromatography/mass spectrometry (GC/MS). However, a major drawback of this approach is the high cost of the instrument and maintenance. Therefore, an alternative method is needed for quality and authenticity evaluation of civet coffee. A rapid, reliable and cost-effective analysis employing a universal detector, GC coupled with flame ionization detector (FID), and metabolite fingerprinting has been established for discrimination analysis of 37 commercial and non-commercial coffee beans extracts. gas chromatography/flame ionization detector (GC/FID) provided higher sensitivity over a similar range of detected compounds than GC/MS. In combination with multivariate analysis, GC/FID could successfully reproduce quality prediction from GC/MS for differentiation of commercial civet coffee, regular coffee and coffee blend with 50 wt % civet coffee content without prior metabolite details. Our study demonstrated that GC/FID-based metabolite fingerprinting can be effectively actualized as an alternative method for coffee authenticity screening in industries. Copyright © 2015. Published by Elsevier B.V.

  15. Carbohydrate and alditol analysis by high-performance anion-exchange chromatography coupled with electrochemical detection at a cobalt-modified electrode.

    PubMed

    Casella, Innocenzo G; Contursi, Michela

    2003-07-01

    A cobalt oxyhydroxide film dispersed on a carbon electrode surface was characterized and proposed as an amperometric sensor for determination of alditols and carbohydrates in flowing streams. Complex mixtures of carbohydrates were separated by anion-exchange chromatography using a moderately alkaline solution as mobile phase. The cobalt modified electrode (GC-Co) was employed under a constant applied potential of 0.5 V (vs Ag/AgCl). Under these experimental conditions the detection limits (S/N=3) for all analyzed electroactive molecules ranged between 0.3 micromol L(-1) and 1.5 micromol L(-1) and the dynamic linear ranges spanned generally three orders of magnitude above the relevant detection limits. Analytical determinations of carbohydrates and alditols in red and white wines, are reported.

  16. Sex pheromone of orange wheat blossom midge, Sitodiplosis mosellana

    NASA Astrophysics Data System (ADS)

    Gries, Regine; Gries, G.; Khaskin, Grigori; King, Skip; Olfert, Owen; Kaminski, Lori-Ann; Lamb, Robert; Bennett, Robb

    Pheromone extract of the female orange wheat blossom midge, Sitodiplosis mosellana (Géhin) (SM) (Diptera: Cecidomyiidae), was analyzed by coupled gas chromatographic-electroantennographic detection (GC-EAD) and GC-mass spectrometry (MS), employing fused silica columns coated with DB-5, DB-210, DB-23 or SP-1000. These analyses revealed a single, EAD-active candidate pheromone which was identified as 2,7-nonanediyl dibutyrate. In experiments in wheat fields in Saskatchewan, traps baited with (2S,7S)-2,7-nonanediyl dibutyrate attracted significant numbers of male SM. The presence of other stereoisomers did not adversely affect trap captures. Facile synthesis of stereoisomeric 2,7-nonanediyl dibutyrate will facilitate the development of pheromone-based monitoring or even control of SM populations.

  17. Evaluation of gas chromatography-tandem quadrupole mass spectrometry for the determination of organochlorine pesticides in fats and oils.

    PubMed

    Patel, Katan; Fussell, Richard J; Hetmanski, Mike; Goodall, David M; Keely, Brendan J

    2005-03-18

    A gas chromatography-tandem quadrupole mass spectrometry multi-residue method for the analysis of 19 organochlorine pesticides in fats and oils has been developed. Gel permeation chromatography was employed to remove lipid material prior to GC-MS/MS analysis. Average recoveries of the pesticides spiked at 10 and 50 microg kg(-1) into fish oil, pork fat, olive oil and hydrogenated vegetable oil were typically in the range 70-110% with relative standard deviations generally less than 10%. Calculated limits of detection are between 0.1 and 2.0 microg kg(-1) and results obtained for the analysis of proficiency test materials are in good agreement with assigned values. The higher selectivity of the GC-MS/MS compared to electron capture detection and GC-MS in selective ion monitoring mode allowed unambiguous identification and confirmation of all the target pesticides at low microg kg(-1) levels in fats and oils in a single analysis.

  18. Pollinator specificity, floral odour chemistry and the phylogeny of Australian sexually deceptive Chiloglottis orchids: implications for pollinator-driven speciation.

    PubMed

    Peakall, Rod; Ebert, Daniel; Poldy, Jacqueline; Barrow, Russell A; Francke, Wittko; Bower, Colin C; Schiestl, Florian P

    2010-10-01

    • Sexually deceptive orchids are predicted to represent a special case of plant speciation where strong reproductive isolation may be achieved by differences in floral scent. • In this study of Australian sexually deceptive Chiloglottis orchids, we performed choice experiments to test for wasp pollinator specificity in the field; identified the compounds involved in pollinator attraction by gas chromatography with electroantennographic detection (GC-EAD), gas chromatography with mass selective detection (GC-MS), chemical synthesis and behavioural bioassays; and mapped our chemical findings on to a phylogeny of the orchids. • Field experiments confirmed pollination is a highly specific interaction, but also revealed a pool of nonpollinating 'minor responder' wasps. Six novel compounds, all 2,5-dialkylcyclohexan-1,3-diones, called 'chiloglottones', were discovered to be involved in pollinator attraction. Bioassays confirmed that pollinator specificity has a strong chemical basis, with specificity among sympatric orchids maintained by either different single compounds or a variation in a blend of two compounds. The phylogenetic overlay confirmed that speciation is always associated with pollinator switching and usually underpinned by chemical change. • If the chemical differences that control reproductive isolation in Chiloglottis have a strong genetic basis, and given the confirmed pool of potential pollinators, we conclude that pollinator-driven speciation appears highly plausible in this system. © The Authors (2010). Journal compilation © New Phytologist Trust (2010).

  19. Determination of organochlorine pesticides in skins and leather by gas chromatography.

    PubMed

    Font, J; Marsal, A

    1998-06-19

    The simultaneous determination of residues of lindane (gamma-HCH) and 10 other organochlorine pesticides (OCPs) in skins and leather was carried out by gas chromatography (GC) with electron-capture detection (ECD). GC with mass spectrometric detection was used to identity confirmation. Samples were extracted with hexane. The extracts were concentrated, and cleaned up on a Florisil column. Dibromooctafluorobiphenyl was added as internal standard. Hide fortifications of 0.5 an d5.0 ppm yielded average lindane recoveries of 98% and 96%, respectively. OCPs was determined in 57 samples of skins purchased from American, European and African countries in 1996-1997. OCPs were not detected in any of the American and European samples. Residues of lindane were found in 56% of African samples.

  20. Comparison of liquid chromatography-isotope ratio mass spectrometry (LC/IRMS) and gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) for the determination of collagen amino acid δ13C values for palaeodietary and palaeoecological reconstruction.

    PubMed

    Dunn, Philip J H; Honch, Noah V; Evershed, Richard P

    2011-10-30

    Results are presented of a comparison of the amino acid (AA) δ(13)C values obtained by gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) and liquid chromatography-isotope ratio mass spectrometry (LC/IRMS). Although the primary focus was the compound-specific stable carbon isotope analysis of bone collagen AAs, because of its growing application for palaeodietary and palaeoecological reconstruction, the results are relevant to any field where AA δ(13)C values are required. We compare LC/IRMS with the most up-to-date GC/C/IRMS method using N-acetyl methyl ester (NACME) AA derivatives. This comparison involves the analysis of standard AAs and hydrolysates of archaeological human bone collagen, which have been previously investigated as N-trifluoroacetyl isopropyl esters (TFA/IP). It was observed that, although GC/C/IRMS analyses required less sample, LC/IRMS permitted the analysis of a wider range of AAs, particularly those not amenable to GC analysis (e.g. arginine). Accordingly, reconstructed bulk δ(13)C values based on LC/IRMS-derived δ(13)C values were closer to the EA/IRMS-derived δ(13)C values than those based on GC/C/IRMS values. The analytical errors for LC/IRMS AA δ(13)C values were lower than GC/C/IRMS determinations. Inconsistencies in the δ(13)C values of the TFA/IP derivatives compared with the NACME- and LC/IRMS-derived δ(13)C values suggest inherent problems with the use of TFA/IP derivatives, resulting from: (i) inefficient sample combustion, and/or (ii) differences in the intra-molecular distribution of δ(13)C values between AAs, which are manifested by incomplete combustion. Close similarities between the NACME AA δ(13)C values and the LC/IRMS-derived δ(13)C values suggest that the TFA/IP derivatives should be abandoned for the natural abundance determinations of AA δ(13)C values. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Metabolomics and Trace Element Analysis of Camel Tear by GC-MS and ICP-MS.

    PubMed

    Ahamad, Syed Rizwan; Raish, Mohammad; Yaqoob, Syed Hilal; Khan, Altaf; Shakeel, Faiyaz

    2017-06-01

    Camel tear metabolomics and elemental analysis are useful in getting the information regarding the components responsible for maintaining the protective system that allows living in the desert and dry regions. The aim of this study was to correlate that the camel tears can be used as artificial tears for the evaluation of dryness in the eye. Eye biomarkers of camel tears were analyzed by gas chromatography-mass spectroscopy (GC-MS) and inductively coupled plasma mass spectroscopy (ICP-MS). The major compounds detected in camel tears by GC-MS were alanine, valine, leucine, norvaline, glycine, cadaverine, urea, ribitol, sugars, and higher fatty acids like octadecanoic acid and hexadecanoic acid. GC-MS analysis of camel tears also finds several products of metabolites and its associated metabolic participants. ICP-MS analysis showed the presence of different concentration of elemental composition in the camel tears.

  2. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    PubMed

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  3. Dioxin analysis by gas chromatography-Fourier transform ion cyclotron resonance mass spectrometry (GC-FTICRMS).

    PubMed

    Taguchi, Vince Y; Nieckarz, Robert J; Clement, Ray E; Krolik, Stefan; Williams, Robert

    2010-11-01

    The feasibility of utilizing a gas chromatograph-tandem quadrupole-Fourier transform ion cyclotron resonance mass spectrometer (GC-MS/MS-FTICRMS) to analyze chlorinated-dioxins/furans (CDDs/CDFs) and mixed halogenated dioxins/furans (HDDs/HDFs) was investigated by operating the system in the GC-FTICRMS mode. CDDs/CDFs and mixed HDDs/HDFs could be analyzed at 50,000 to 100,000 resolving power (RP) on the capillary gas chromatographic time scale. Initial experiments demonstrated that 1 pg of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 5 pg of 2-bromo-3,7,8-trichlorodibenzo-p-dioxin (BTrCDD) could be detected. The feasibility of utilizing an FTICRMS for screening of CDDs/CDFs, HDDs/HDFs and related compounds was also investigated by analyzing an extract from vegetation exposed to fall-out from an industrial fire. CDDs/CDFs, chlorinated pyrenes and chlorinated tetracenes could be detected from a Kendrick plot analysis of the ultrahigh resolution mass spectra. Mass accuracies were of the order of 0.5 ppm on standards with external mass calibration and 1 ppm on a sample with internal mass calibration. Copyright © 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  4. Determination of trace level genotoxic impurities in small molecule drug substances using conventional headspace gas chromatography with contemporary ionic liquid diluents and electron capture detection.

    PubMed

    Ho, Tien D; Yehl, Peter M; Chetwyn, Nik P; Wang, Jin; Anderson, Jared L; Zhong, Qiqing

    2014-09-26

    Ionic liquids (ILs) were used as a new class of diluents for the analysis of two classes of genotoxic impurities (GTIs), namely, alkyl/aryl halides and nitro-aromatics, in small molecule drug substances by headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD). This novel approach using ILs as contemporary diluents greatly broadens the applicability of HS-GC for the determination of high boiling (≥ 130°C) analytes including GTIs with limits of detection (LOD) ranging from 5 to 500 parts-per-billion (ppb) of analytes in a drug substance. This represents up to tens of thousands-fold improvement compared to traditional HS-GC diluents such as dimethyl sulfoxide (DMSO) and dimethylacetamide (DMAC). Various ILs were screened to determine their suitability as diluents for the HS-GC/ECD analysis. Increasing the HS oven temperatures resulted in varying responses for alkyl/aryl halides and a significant increase in response for all nitroaromatic GTIs. Linear ranges of up to five orders of magnitude were found for a number of analytes. The technique was validated on two active pharmaceutical ingredients with excellent recovery. This simple and robust methodology offers a key advantage in the ease of method transfer from development laboratories to quality control environments since conventional validated chromatographic data systems and GC instruments can be used. For many analytes, it is a cost effective alternative to more complex trace analytical methodologies like LC/MS and GC/MS, and significantly reduces the training needed for operation. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography.

    PubMed

    Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD < 3%), accuracy (100.68-102.69%), and robustness. The UHPLC-DAD/GC-MS method was successfully utilized to analyze volatile components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.

  6. GC-FID coupled with chemometrics for quantitative and chemical fingerprinting analysis of Alpinia oxyphylla oil.

    PubMed

    Miao, Qing; Kong, Weijun; Zhao, Xiangsheng; Yang, Shihai; Yang, Meihua

    2015-01-01

    Analytical methods for quantitative analysis and chemical fingerprinting of volatile oils from Alpinia oxyphylla were established. The volatile oils were prepared by hydrodistillation, and the yields were between 0.82% and 1.33%. The developed gas chromatography-flame ionization detection (GC-FID) method showed good specificity, linearity, reproducibility, stability and recovery, and could be used satisfactorily for quantitative analysis. The results showed that the volatile oils contained 2.31-77.30 μL/mL p-cymene and 12.38-99.34 mg/mL nootkatone. A GC-FID fingerprinting method was established, and the profiles were analyzed using chemometrics. GC-MS was used to identify the principal compounds in the GC-FID profiles. The profiles of almost all the samples were consistent and stable. The harvesting time and source were major factors that affected the profile, while the volatile oil yield and the nootkatone content had minor secondary effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Analysis of volatiles in fire debris by combination of activated charcoal strips (ACS) and automated thermal desorption-gas chromatography-mass spectrometry (ATD/GC-MS).

    PubMed

    Martin Fabritius, Marie; Broillet, Alain; König, Stefan; Weinmann, Wolfgang

    2018-06-04

    Adsorption of volatiles in gaseous phase to activated charcoal strip (ACS) is one possibility for the extraction and concentration of ignitable liquid residues (ILRs) from fire debris in arson investigations. Besides liquid extraction using carbon dioxide or hexane, automated thermo-desorption can be used to transfer adsorbed residues to direct analysis by gas chromatography-mass spectrometry (GC-MS). We present a fire debris analysis work-flow with headspace adsorption of volatiles onto ACS and subsequent automated thermo-desorption (ATD) GC-MS analysis. Only a small portion of the ACS is inserted in the ATD tube for thermal desorption coupled to GC-MS, allowing for subsequent confirmation analysis with another portion of the same ACS. This approach is a promising alternative to the routinely used ACS method with solvent extraction of retained volatiles, and the application to fire debris analysis is demonstrated. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Gas chromatography fractionation platform featuring parallel flame-ionization detection and continuous high-resolution analyte collection in 384-well plates.

    PubMed

    Jonker, Willem; Clarijs, Bas; de Witte, Susannah L; van Velzen, Martin; de Koning, Sjaak; Schaap, Jaap; Somsen, Govert W; Kool, Jeroen

    2016-09-02

    Gas chromatography (GC) is a superior separation technique for many compounds. However, fractionation of a GC eluate for analyte isolation and/or post-column off-line analysis is not straightforward, and existing platforms are limited in the number of fractions that can be collected. Moreover, aerosol formation may cause serious analyte losses. Previously, our group has developed a platform that resolved these limitations of GC fractionation by post-column infusion of a trap solvent prior to continuous small-volume fraction collection in a 96-wells plate (Pieke et al., 2013 [17]). Still, this GC fractionation set-up lacked a chemical detector for the on-line recording of chromatograms, and the introduction of trap solvent resulted in extensive peak broadening for late-eluting compounds. This paper reports advancements to the fractionation platform allowing flame ionization detection (FID) parallel to high-resolution collection of a full GC chromatograms in up to 384 nanofractions of 7s each. To this end, a post-column split was incorporated which directs part of the eluate towards FID. Furthermore, a solvent heating device was developed for stable delivery of preheated/vaporized trap solvent, which significantly reduced band broadening by post-column infusion. In order to achieve optimal analyte trapping, several solvents were tested at different flow rates. The repeatability of the optimized GC fraction collection process was assessed demonstrating the possibility of up-concentration of isolated analytes by repetitive analyses of the same sample. The feasibility of the improved GC fractionation platform for bioactivity screening of toxic compounds was studied by the analysis of a mixture of test pesticides, which after fractionation were subjected to a post-column acetylcholinesterase (AChE) assay. Fractions showing AChE inhibition could be unambiguously correlated with peaks from the parallel-recorded FID chromatogram. Copyright © 2016 Elsevier B.V. All rights

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organochlorine pesticides and polychlorinated biphenyls in bottom and suspended sediment by gas chromatography with electron-capture detection

    USGS Publications Warehouse

    Noriega, Mary C.; Wydoski, Duane S.; Foreman, William T.

    2004-01-01

    A method applicable for the determination of 19 organochlorine (OC) pesticides, including total toxaphene as a complex mixture, and 3 polychlorinated biphenyl (PCB) mixtures as Aroclor equivalents--Aroclor 1016/1242, 1254, and 1260--in soil, aquatic bottom sediment, and suspended sediment is described. Method performance data are presented. The solvent system is designed to extract simultaneously selected OC pesticides and PCBs from the same sample matrix. The compounds are extracted by conventional Soxhlet extraction with dichloromethane, followed by partial isolation using gel permeation chromatography (GPC) to remove inorganic sulfur and large naturally present molecules from the sediment extract. The aliquot of extract collected from the GPC for OCs (OC pesticides and PCBs) is split into two sample fractions by alumina/silica combined-column chromatography, followed by Florisil adsorption chromatography to remove interfering compounds in the second fraction. The OC fractions are analyzed by dual capillary-column gas chromatography with electron-capture detection (GC/ECD). This report is limited to the determination of selected OC pesticides and PCBs by GC/ECD using this method. Interim reporting levels (IRLs) have been set at 0.400 to 3.12 micrograms per kilogram for 18 individual OC pesticides, 200 micrograms per kilogram for toxaphene, and 4.04 to 4.68 micrograms per kilogram for the PCBs, based on a sample size of 25-gram equivalent dry weight. These reporting levels may change following additional determinations of method detection limits.

  10. Incorporation of Gas Chromatography-Mass Spectrometry into the Undergraduate Organic Chemistry Laboratory Curriculum

    ERIC Educational Resources Information Center

    Giarikos, Dimitrios G.; Patel, Sagir; Lister, Andrew; Razeghifard, Reza

    2013-01-01

    Gas chromatography-mass spectrometry (GC-MS) is a powerful analytical tool for detection, identification, and quantification of many volatile organic compounds. However, many colleges and universities have not fully incorporated this technique into undergraduate teaching laboratories despite its wide application and ease of use in organic…

  11. DIRECT-DEPOSITION INFRARED SPECTROMETRY WITH GAS AND SUPERCRITICAL FLUID CHROMATOGRAPHY

    EPA Science Inventory

    A direct-deposition Fourier transform infrared (FT-IR) system has been evaluated for applicability to gas chromatography (GC) and supercritical fluid chromatography (SFC) of environmental analytes. A 100-um i.d. fused-silica transfer line was used for GC, and a 50-um transfer lin...

  12. Axial thermal gradients in microchip gas chromatography.

    PubMed

    Wang, Anzi; Hynynen, Sampo; Hawkins, Aaron R; Tolley, Samuel E; Tolley, H Dennis; Lee, Milton L

    2014-12-29

    Fabrication technologies for microelectromechanical systems (MEMS) allow miniaturization of conventional benchtop gas chromatography (GC) to portable, palm-sized microfabricated GCGC) devices, which are suitable for on-site chemical analysis and remote sensing. The separation performance of μGC systems, however, has not been on par with conventional GC. Column efficiency, peak symmetry and resolution are often compromised by column defects and non-ideal injections. The relatively low performance of μGC devices has impeded their further commercialization and broader application. In this work, the separation performance of μGC columns was improved by incorporating thermal gradient gas chromatography (TGGC). The analysis time was ∼20% shorter for TGGC separations compared to conventional temperature-programmed GC (TPGC) when a wide sample band was introduced into the column. Up to 50% reduction in peak tailing was observed for polar analytes, which improved their resolution. The signal-to-noise ratios (S/N) of late-eluting peaks were increased by 3-4 fold. The unique focusing effect of TGGC overcomes many of the previous shortcomings inherent in μGC analyses. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Multidimensional gas chromatography in combination with accurate mass, tandem mass spectrometry, and element-specific detection for identification of sulfur compounds in tobacco smoke.

    PubMed

    Ochiai, Nobuo; Mitsui, Kazuhisa; Sasamoto, Kikuo; Yoshimura, Yuta; David, Frank; Sandra, Pat

    2014-09-05

    A method is developed for identification of sulfur compounds in tobacco smoke extract. The method is based on large volume injection (LVI) of 10μL of tobacco smoke extract followed by selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography (GC) coupled to a hybrid quadrupole time-of-flight mass spectrometer (Q-TOF-MS) using electron ionization (EI) and positive chemical ionization (PCI), with parallel sulfur chemiluminescence detection (SCD). In order to identify each individual sulfur compound, sequential heart-cuts of 28 sulfur fractions from (1)D GC to (2)D GC were performed with the three MS detection modes (SCD/EI-TOF-MS, SCD/PCI-TOF-MS, and SCD/PCI-Q-TOF-MS). Thirty sulfur compounds were positively identified by MS library search, linear retention indices (LRI), molecular mass determination using PCI accurate mass spectra, formula calculation using EI and PCI accurate mass spectra, and structure elucidation using collision activated dissociation (CAD) of the protonated molecule. Additionally, 11 molecular formulas were obtained for unknown sulfur compounds. The determined values of the identified and unknown sulfur compounds were in the range of 10-740ngmg total particulate matter (TPM) (RSD: 1.2-12%, n=3). Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Combined thin layer chromatography and gas chromatography with mass spectrometric analysis of lipid classes and fatty acids in malnourished polar bears (Ursus maritimus) which swam to Iceland.

    PubMed

    Eibler, Dorothee; Krüger, Sabine; Skírnisson, Karl; Vetter, Walter

    2017-03-01

    Between 2008 and 2011, four polar bears (Ursus maritimus) from the Greenland population swam and/or drifted on ice to Iceland where they arrived in very poor body condition. Body fat resources in these animals were only between 0% and 10% of the body weight (usually 25%). Here we studied the lipid composition in different tissues (adipose tissue if available, liver, kidney and muscle). Lipid classes were determined by thin layer chromatography (TLC) and on-column gas chromatography with mass spectrometry (GC/MS). The fatty acid pattern of total lipids and free fatty acids was analyzed by GC/MS in selected ion monitoring (SIM) mode. Additionally, cholesteryl esters and native fatty acid methyl esters, initially detected as zones in thin layer chromatograms, were enriched by solid phase extraction and quantified by GC/MS. The ratio of free fatty acids to native fatty acid methyl esters could be correlated with the remained body lipids in the polar bears and thus may also serve as a marker for other starving animals or even for humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Determination of volatile marker compounds in raw ham using headspace-trap gas chromatography.

    PubMed

    Bosse Née Danz, Ramona; Wirth, Melanie; Konstanz, Annette; Becker, Thomas; Weiss, Jochen; Gibis, Monika

    2017-03-15

    A simple, reliable and automated method was developed and optimized for qualification and quantification of aroma-relevant volatile marker compounds of North European raw ham using a headspace (HS)-Trap gas chromatography-mass spectrometry (GC-MS) and GC-flame ionization detector (FID) analysis. A total of 38 volatile compounds were detected with this HS-Trap GC-MS method amongst which the largest groups were ketones (12), alcohols (8), hydrocarbons (7), aldehydes (6) and esters (3). The HS-Trap GC-FID method was optimized for the parameters: thermostatting time and temperature, vial and desorption pressure, number of extraction cycles and salt addition. A validation for 13 volatile marker compounds with limits of detection in ng/g was carried out. The optimized method can serve as alternative to conventional headspace and solid phase micro extraction methods and allows users to determine volatile compounds in raw hams making it of interest to industrial and academic meat scientists. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Acrylamide: formation, occurrence in food products, detection methods, and legislation.

    PubMed

    Arvanitoyannis, Ioannis S; Dionisopoulou, Niki

    2014-01-01

    This review aims at summarizing the most recent updates in the field of acrylamide (AA) formation (mechanism, conditions) and the determination of AA in a number of foods (fried or baked potatoes, chips, coffee, bread, etc). The methods applied for AA detection [Capillary Electrophoresis-Mass Spectrometry (CE-MS), Liquid Chromatography-Mass Spectrometry (LC-MS), Non-Aqueous Capillary Electrophoresis (NACE), High Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS), Pressurized Fluid Extraction (PFE), Matrix Solid-Phase Dispersion (MSPD), Gas Chromatography-Mass Spectrometry (GC-MS), Solid-Phase MicroExtraction-Gas Chromatography (SPME-GC), Enzyme Linked Immunosorbent Assay (ELISA), and MicroEmulsion ElectroKinetic Chromatography (MEEKC) are presented and commented. Several informative figures and tables are included to show the effect of conditions (temperature, time) on the AA formation. A section is also included related to AA legislation in EU and US.

  17. Gas and liquid chromatography with inductively coupled plasma mass spectrometry detection for environmental speciation analysis — advances and limitations

    NASA Astrophysics Data System (ADS)

    Szpunar, Joanna; McSheehy, Shona; Połeć, Kasia; Vacchina, Véronique; Mounicou, Sandra; Rodriguez, Isaac; Łobiński, Ryszard

    2000-07-01

    Recent advances in the coupling of gas chromatography (GC) and high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP MS) and their role in trace element speciation analysis of environmental materials are presented. The discussion is illustrated with three research examples concerning the following topics: (i) development and coupling of multicapillary microcolumn GC with ICP MS for speciation of organotin in sediment and biological tissue samples; (ii) speciation of arsenic in marine algae by size-exclusion-anion-exchange HPLC-ICP MS; and (iii) speciation of cadmium in plant cell cultures by size-exclusion HPLC-ICP MS. Particular attention is paid to the problem of signal identification in ICP MS chromatograms; the potential of electrospray MS/MS for this purpose is highlighted.

  18. Volatile and key odourant compounds of Turkish Berberis crataegina fruit using GC-MS-Olfactometry.

    PubMed

    Sonmezdag, Ahmet Salih; Kelebek, Hasim; Selli, Serkan

    2018-04-01

    This research was conducted to identify the aroma and aroma-active compounds of Berberis crataegina for the first time. Volatile profile of B. crataegina was obtained using the purge and trap extraction method with dichloromethane. Gas chromatography was coupled to mass spectrometry (GC-MS) allowed the quantitative and qualitative detection of 22 compounds in the sample. Aldehydes were the main chemical group in the sample and followed by aromatic alcohols and lactone. Aroma extract dilution analysis was implemented for the specification of key odourants of B. crataegina. In total, eight key odourants were detected in the extract of the sample, using GC-MS-Olfactometry and aldehydes were the leading chemical group. The key odourants, found to be contributing to the overall aroma in B. crataegina, were nonanal (FD = 1024; green, flowery), hexanal (FD = 512; green) and linalool (FD = 256; flowery, rose) because of high FD factors.

  19. Development of a sensitive GC-C-IRMS method for the analysis of androgens.

    PubMed

    Polet, Michael; Van Gansbeke, Wim; Deventer, Koen; Van Eenoo, Peter

    2013-02-01

    The administration of anabolic steroids is one of the most important issues in doping control and is detectable through a change in the carbon isotopic composition of testosterone and/or its metabolites. Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS), however, remains a very laborious and expensive technique and substantial amounts of urine are needed to meet the sensitivity requirements of the IRMS. This can be problematic because only a limited amount of urine is available for anti-doping analysis on a broad spectrum of substances. In this work we introduce a new type of injection that increases the sensitivity of GC-C-IRMS by a factor of 13 and reduces the limit of detection, simply by using solvent vent injections instead of splitless injection. This drastically reduces the amount of urine required. On top of that, by only changing the injection technique, the detection parameters of the IRMS are not affected and there is no loss in linearity. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    PubMed Central

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  1. Detecting Pyrolysis Products from Bacteria on Mars

    NASA Technical Reports Server (NTRS)

    Glavin, Daniel; Schubert, Michael; Botta, Oliver; Kminek, Gerhard; Bada, Jeffrey L.

    2001-01-01

    A pyrolysis/sublimation technique was developed to isolate volatile amine compounds from a Mars soil analogue inoculated with approx. 10 billion Escherichia coli cells. In this technique, the inoculated soil is heated to 500 C for several seconds at Martian ambient pressure and the sublimate, collected by a cold finger, then analyzed using high performance liquid chromatography. Methylamine and ethylamine, produced from glycine and alanine decarboxylation, were the most abundant amine compounds detected after pyrolysis of the cells. A heating cycle similar to that utilized in our experiment was also used to release organic compounds from the Martian soil in the 1976 Viking gas chromatography/mass spectrometry (GC/MS) pyrolysis experiment. The Viking GC/MS did not detect any organic compounds of Martian origin above a level of a few parts per billion in the Martian surface soil. Although the Viking GC/MS instruments were not specifically designed to search for the presence of living cells on Mars, our experimental results indicate that at the part per billion level, the degradation products generated from several million bacterial cells per gram of Martian soil would not have been detected.

  2. Gas chromatography coupled to atmospheric pressure ionization mass spectrometry (GC-API-MS): review.

    PubMed

    Li, Du-Xin; Gan, Lin; Bronja, Amela; Schmitz, Oliver J

    2015-09-03

    Although the coupling of GC/MS with atmospheric pressure ionization (API) has been reported in 1970s, the interest in coupling GC with atmospheric pressure ion source was expanded in the last decade. The demand of a "soft" ion source for preserving highly diagnostic molecular ion is desirable, as compared to the "hard" ionization technique such as electron ionization (EI) in traditional GC/MS, which fragments the molecule in an extensive way. These API sources include atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), atmospheric pressure laser ionization (APLI), electrospray ionization (ESI) and low temperature plasma (LTP). This review discusses the advantages and drawbacks of this analytical platform. After an introduction in atmospheric pressure ionization the review gives an overview about the history and explains the mechanisms of various atmospheric pressure ionization techniques used in combination with GC such as APCI, APPI, APLI, ESI and LTP. Also new developments made in ion source geometry, ion source miniaturization and multipurpose ion source constructions are discussed and a comparison between GC-FID, GC-EI-MS and GC-API-MS shows the advantages and drawbacks of these techniques. The review ends with an overview of applications realized with GC-API-MS. Copyright © 2015. Published by Elsevier B.V.

  3. A Laboratory Experiment To Measure Henry's Law Constants of Volatile Organic Compounds with a Bubble Column and a Gas Chromatography Flame Ionization Detector (GC-FID)

    ERIC Educational Resources Information Center

    Lee, Shan-Hu; Mukherjee, Souptik; Brewer, Brittany; Ryan, Raphael; Yu, Huan; Gangoda, Mahinda

    2013-01-01

    An undergraduate laboratory experiment is described to measure Henry's law constants of organic compounds using a bubble column and gas chromatography flame ionization detector (GC-FID). This experiment is designed for upper-division undergraduate laboratory courses and can be implemented in conjunction with physical chemistry, analytical…

  4. Metabolism of the new designer drug alpha-pyrrolidinopropiophenone (PPP) and the toxicological detection of PPP and 4'-methyl-alpha-pyrrolidinopropiophenone (MPPP) studied in rat urine using gas chromatography-mass spectrometry.

    PubMed

    Springer, Dietmar; Fritschi, Giselher; Maurer, Hans H

    2003-11-05

    R,S-alpha-pyrrolidinopropiophenone (PPP) is a new designer drug with assumed amphetamine-like effects which has appeared on the illicit drug market. The aim of this study was to identify the PPP metabolites using solid-phase extraction, ethylation or acetylation as well as to develop a toxicological detection procedure in urine using solid-phase extraction, trimethylsilylation and gas chromatography-mass spectrometry (GC-MS). Analysis of urine samples of rats treated with PPP revealed that PPP was extensively metabolized by hydroxylation of the pyrrolidine ring with subsequent dehydrogenation to the corresponding lactam, hydroxylation of the aromatic ring in position 4' or double dealkylation of the pyrrolidine ring to the corresponding primary amine (cathinone) partly followed by reduction of the keto group to the corresponding secondary alcohol (norephedrines). As cathinone and the norephedrine diastereomers are also formed after intake of other drugs of abuse or medicaments, special attention must be paid to the detection of the unequivocal metabolite 2"-oxo-PPP as an unambiguous proof for the intake of PPP. The hydroxy groups were found to be partly conjugated. Based on these data, PPP could be detected in urine via its metabolites by full-scan GC-MS using mass chromatography for screening and library search for identification by comparison of the spectra with reference spectra. The same toxicological detection procedure can be applied to other designer drugs of the pyrrolidinophenone type, like MOPPP, MDPPP, MPHP, and MPPP. The detection of the latter will also be presented here.

  5. Qualitative and quantitative determination of extractives in heartwood of Scots pine (Pinus sylvestris L.) by gas chromatography.

    PubMed

    Ekeberg, Dag; Flaete, Per-Otto; Eikenes, Morten; Fongen, Monica; Naess-Andresen, Carl Fredrik

    2006-03-24

    A method for quantitative determination of extractives from heartwood of Scots pine (Pinus sylvestris L.) using gas chromatography (GC) with flame ionization detection (FID) was developed. The limit of detection (LOD) was 0.03 mg/g wood and the linear range (r = 0.9994) was up to 10 mg/g with accuracy within +/- 10% and precision of 18% relative standard deviation. The identification of the extractives was performed using gas chromatography combined with mass spectrometry (GC-MS). The yields of extraction by Soxhlet were tested for solid wood, small particles and fine powder. Small particles were chosen for further analysis. This treatment gave good yields of the most important extractives: pinosylvin, pinosylvin monomethyl ether, resin acids and free fatty acids. The method is used to demonstrate the variation of these extractives across stems and differences in north-south direction.

  6. Detection and quantification of adulteration of sesame oils with vegetable oils using gas chromatography and multivariate data analysis.

    PubMed

    Peng, Dan; Bi, Yanlan; Ren, Xiaona; Yang, Guolong; Sun, Shangde; Wang, Xuede

    2015-12-01

    This study was performed to develop a hierarchical approach for detection and quantification of adulteration of sesame oil with vegetable oils using gas chromatography (GC). At first, a model was constructed to discriminate the difference between authentic sesame oils and adulterated sesame oils using support vector machine (SVM) algorithm. Then, another SVM-based model is developed to identify the type of adulterant in the mixed oil. At last, prediction models for sesame oil were built for each kind of oil using partial least square method. To validate this approach, 746 samples were prepared by mixing authentic sesame oils with five types of vegetable oil. The prediction results show that the detection limit for authentication is as low as 5% in mixing ratio and the root-mean-square errors for prediction range from 1.19% to 4.29%, meaning that this approach is a valuable tool to detect and quantify the adulteration of sesame oil. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Analysis of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues in chlorine-treated water by gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS).

    PubMed

    Planas, Carles; Ventura, Francesc; Caixach, Josep; Martín, Jordi; Boleda, M Rosa; Paraira, Miquel

    2015-11-01

    A simple, selective and sensitive method for the analysis of the strong mutagen 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its brominated analogues (BMXs) in chlorine-treated water has been developed. The method is based on gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS), previous liquid-liquid extraction (LLE) of a smaller sample volume compared to other methods and on-line derivatization with a silylation reactive. GC-QqQ-MS/MS has been raised as an alternative easier to perform than gas chromatography coupled to high resolution mass spectrometry (GC-HRMS) for the analysis of MX and BMXs, and it allows to achieve low LODs (0.3 ng/L for MX and 0.4-0.9 ng/L for BMXs). This technique had not been previously described for the analysis of MX and BMXs. Quality parameters were calculated and real samples related to 3 drinking water treatment plants (DWTPs), tap water and both untreated and chlorinated groundwater were analyzed. Concentrations of 0.3-6.6 ng/L for MX and 1.0-7.3 ng/L for BMXs were detected. Results were discussed according to five of the main factors affecting MX and BMXs formation in chlorine-treated water (organic precursors, influence of bromide ions, evolution of MX and BMXs in the drinking water distribution system, groundwater chlorination and infiltration of water coming from chlorination processes in groundwater). Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Comparison of different mass spectrometric approaches coupled to gas chromatography for the analysis of organochlorine pesticides in serum samples.

    PubMed

    Fang, Jing; Wu, Qian; Zhao, Yun; Zhao, Hongzhi; Xu, Shunqing; Cai, Zongwei

    2017-01-01

    Gas chromatography-triple quadrupole mass spectrometry (GC-QqQMS) was applied for the determination of eight organochlorine pesticides (OCPs) in human serum. OCPs were extracted from the serum sample by solid phase extraction (SPE) and analyzed by gas chromatography mass spectrometry (GC-MS) or gas chromatography tandem mass spectrometry (GC-MS/MS). Electron ionization (EI) and negative chemical ionization (NCI) under two data acquisition modes, namely selected ion monitoring (SIM) and multiple reaction monitoring (MRM), were compared. The use of MRM generally provided higher selectivity and sensitivity because less interference from the sample matrix existed. The EI mode is more suitable for less electronegative compounds such as dichlorodiphenyldichloroethanes (DDDs) with detection limits ranging from 0.0060 to 0.060ng/mL. In the NCI mode, MRM analysis provided good and lower detection limits (0.0011-0.0030ng/mL) for pesticides containing more chlorines. The methods were validated by analyzing the pesticides in spiked serum at different levels with recoveries ranged from 83% to 116% and relative standard deviations of less than 10%. The developed method was applied for the determination of the OCPs in real human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Supervised Semi-Automated Data Analysis Software for Gas Chromatography / Differential Mobility Spectrometry (GC/DMS) Metabolomics Applications.

    PubMed

    Peirano, Daniel J; Pasamontes, Alberto; Davis, Cristina E

    2016-09-01

    Modern differential mobility spectrometers (DMS) produce complex and multi-dimensional data streams that allow for near-real-time or post-hoc chemical detection for a variety of applications. An active area of interest for this technology is metabolite monitoring for biological applications, and these data sets regularly have unique technical and data analysis end user requirements. While there are initial publications on how investigators have individually processed and analyzed their DMS metabolomic data, there are no user-ready commercial or open source software packages that are easily used for this purpose. We have created custom software uniquely suited to analyze gas chromatograph / differential mobility spectrometry (GC/DMS) data from biological sources. Here we explain the implementation of the software, describe the user features that are available, and provide an example of how this software functions using a previously-published data set. The software is compatible with many commercial or home-made DMS systems. Because the software is versatile, it can also potentially be used for other similarly structured data sets, such as GC/GC and other IMS modalities.

  10. 78 FR 7262 - Airworthiness Directives; EADS CASA (Type Certificate Previously Held by Construcciones...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-01

    ... Airworthiness Directives; EADS CASA (Type Certificate Previously Held by Construcciones Aeron[aacute]uticas, S.A... Certificate previously held by Construcciones Aeron[aacute]uticas, S.A.) Model CN-235, CN-235-100, CN-235-200... Certificate previously held by Construcciones Aeron[aacute]uticas, S.A.): Amendment 39- [[Page 7264

  11. Use of absorbent materials in on-line coupled reversed-phase liquid chromatography-gas chromatography via the through oven transfer adsorption desorption interface.

    PubMed

    Flores, Gema; Díaz-Plaza, Eva María; Cortés, Jose Manuel; Villén, Jesús; Herraiz, Marta

    2008-11-21

    The use of absorbents as retaining materials in the through oven transfer adsorption desorption interface (TOTAD) of an on-line coupled reversed-phase liquid chromatography-gas chromatography system (RPLC-GC) is proposed for the first time. A comparative study of an adsorbent (Tenax TA) and two absorbents, namely polydimethylsiloxane and poly(50% phenyl/50% methylsiloxane) is performed to establish the best experimental conditions for the automated and simultaneous determination of 15 organophosphorus and organochlorine pesticide residues in olive oil. The proposed method provides satisfactory repeatability (RSDs lower, in general, than 8.5%) and sensitivity (limits of detection ranging from 0.6 to 81.9 microg/L) for the investigated compounds.

  12. Paper SERS chromatography for detection of trace analytes in complex samples

    NASA Astrophysics Data System (ADS)

    Yu, Wei W.; White, Ian M.

    2013-05-01

    We report the application of paper SERS substrates for the detection of trace quantities of multiple analytes in a complex sample in the form of paper chromatography. Paper chromatography facilitates the separation of different analytes from a complex sample into distinct sections in the chromatogram, which can then be uniquely identified using SERS. As an example, the separation and quantitative detection of heroin in a highly fluorescent mixture is demonstrated. Paper SERS chromatography has obvious applications, including law enforcement, food safety, and border protection, and facilitates the rapid detection of chemical and biological threats at the point of sample.

  13. Applications of Hadamard transform-gas chromatography/mass spectrometry to the detection of acetone in healthy human and diabetes mellitus patient breath.

    PubMed

    Fan, Gang-Ting; Yang, Chien-Lin; Lin, Cheng-Huang; Chen, Chien-Chung; Shih, Chung-Hung

    2014-03-01

    The Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) technique was successfully employed to detect acetone, a biomarker for diabetes mellitus (DM) prediction, in human breath. Samples of exhaled breath were collected from four DM patients (one type-I and three type-II) and eight volunteers (nondiabetic healthy subjects), respectively. The gas samples, without any pretreatment, were simultaneously injected into a GC column through a Hadamard-injector based on Hadamard codes. Under optimized conditions, when cyclic S-matrix orders of 255, 1023 and 2047 were used, the S/N ratios of the acetone signals were substantially improved by 8.0-, 16.0- and 22.6-fold, respectively; these improvements are in good agreement with theoretically calculated values. We found that the breath acetone concentration levels in the four DM patients and the eight volunteers ranged from 1 to 10 ppmv and 0.1 to 1 ppmv, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. SPE-GC/FTD determination of N-methyl-2-pyrrolidone and its metabolites in urine.

    PubMed

    Kubota, Ryuichi; Endo, Yoko; Takeuchi, Akito; Inoue, Yoshinori; Ogata, Hiroko; Ogawa, Masanori; Nakagawa, Tomoo; Onda, Nobuhiko; Endo, Ginji

    2007-07-01

    An analytical method using a combination of solid-phase extraction (SPE) and gas chromatography with a flame thermionic detector (GC/FTD) was developed for determination of N-methyl-2-pyrrolidone (NMP), N-methylsuccinimide (MSI), and 2-hydroxy-N-methylsuccinimide (2-HMSI) in human urine. The SPE cartridge of poly(divinylbenzene/hydroxymethacrylate) used was directly loaded with urine sample, followed by elution with methyl isobutyl ketone (MIBK) and subsequent centrifugation, and the supernatant was injected into the capillary GC using a DB1701. This method allowed efficient separation of NMP, MSI, and 2-HMSI, which were nearly free of interference by other GC peaks arising from urine. Recoveries of NMP, MSI, and 2-HMSI from the SPE cartridge were about 98, 101, and 67%, respectively, with limits of detection of 0.04, 0.02, and 0.06 mg/L, respectively, which met the regulatory requirements. The present method was used for assay in biological monitoring of workers exposed to NMP in their occupational environment.

  15. Helium microwave-induced plasmas for element specific detection in chromatography

    NASA Astrophysics Data System (ADS)

    Long, Gary L.; Ducatte, Gerald R.; Lancaster, Edwin D.

    1994-01-01

    This review addresses the development and use of the microwave-induced plasma (MIP) using optical emission spectrometry for the purpose of element specific detection in chromatography. The plasma source that is the focus of this article is the He-based MIP operated at atmospheric pressure. The forms of chromatography that are covered include gas chromatography, liquid chromatography, and supercritical fluid chromatography. Concepts in plasma cavity design and the chromatograph-plasma interface are discussed along with the application of these hybrid systems to analytical determinations.

  16. Validation of a method to detect cocaine and its metabolites in nails by gas chromatography-mass spectrometry.

    PubMed

    Valente-Campos, Simone; Yonamine, Mauricio; de Moraes Moreau, Regina Lucia; Silva, Ovandir Alves

    2006-06-02

    The objective of the present work was to compare previously published methods and provide validation data to detect simultaneously cocaine (COC), benzoylecgonine (BE) and norcocaine (NCOC) in nail. Finger and toenail samples (5mg) were cut in very small pieces and submitted to an initial procedure for external decontamination. Methanol (3 ml) was used to release analytes from the matrix. A cleanup step was performed simultaneously by solid-phase extraction (SPE) and the residue was derivatized with pentafluoropropionic anhydride/pentafluoropropanol (PFPA/PFP). Gas chromatography-mass spectrometry (GC-MS) was used to detect the analytes in selected ion monitoring mode (SIM). Confidence parameters of validation of the method were: recovery, intra- and inter-assay precision, as well as limit of detection (LOD) of the analytes. The limits of detection were: 3.5 ng/mg for NCOC and 3.0 ng/mg for COC and BE. Good intra-assay precision was observed for all detected substances (coefficient of variation (CV)<11%). The inter-assay precision for norcocaine and benzoylecgonine were <4%. For intra- and inter-assay precision deuterated internal standards were used. Toenail and fingernail samples from eight declared cocaine users were submitted to the validated method.

  17. The measurement of muscle protein synthesis in broilers with a flooding dose technique: use of 15N-labelled phenylalanine, GC-MS and GC-C-IRMS.

    PubMed

    Dänicke, S; Böttcher, W; Simon, O; Jeroch, H

    2001-01-01

    An experiment was carried out to measure fractional muscle protein synthesis rates (k(s)) in broilers with injection of a flooding dose of phenylalanine (1 ml/100 g body weight of 150 mM phenylalanine; 38 atom percent excess (APE) [15N]phenylalanine). K(s) was calculated from the [15N] enrichment in phenylalanine of tissue-free and protein-bound phenylalanine using both gas chromatography mass spectrometry (GC-MS) and gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) for measurements after a 10 min isotope incorporation period. The tertiary-butyldimethylsilyl (t-BDMS) derivatives of phenylalanine were used for gas chromatographic separation in both systems. GC-MS and GC-C-IRMS were calibrated for a range of 7 to 37 [15N]APE and 0 to 0.62 [15N]APE, respectively, and for sample sizes of 0.45 to 4.5 nmol phenylalanine and 7 to 40 nmol phenylalanine, respectively. Reproducibility of standards as a measure of precision varied from 0.06 to 0.29 [15N]APE and from 0.0004 to 0.0018 [15N]APE in GC-MS and GC-C-IRMS, respectively. K(s) was measured in the m. pectoralis major of broilers fed rye based diets (56%) which were provided either unsupplemented (-) or supplemented (+) with an enzyme preparation containing xylanase. K(s) in breast muscles was significantly increased from 21.8%/d to 23.9%/d due to enzyme supplementation. It can be concluded from the study that the measurement of protein synthesis in broilers with the flooding dose technique can be carried out by using [15N]phenylalanine, GC-MS and GC-C-IRMS.

  18. Rapid determination of floral aroma compounds of lilac blossom by fast gas chromatography combined with surface acoustic wave sensor.

    PubMed

    Oh, Se Yeon; Shin, Hyun Du; Kim, Sung Jean; Hong, Jongki

    2008-03-07

    A novel analytical method using fast gas chromatography combined with surface acoustic wave sensor (GC/SAW) has been developed for the detection of volatile aroma compounds emanated from lilac blossom (Syringa species: Syringa vulgaris variginata and Syringa dilatata). GC/SAW could detect and quantify various fragrance emitted from lilac blossom, enabling to provide fragrance pattern analysis results. The fragrance pattern analysis could easily characterize the delicate differences in aromas caused by the substantial difference of chemical composition according to different color and shape of petals. Moreover, the method validation of GC/SAW was performed for the purpose of volatile floral actual aroma analysis, achieving a high reproducibility and excellent sensitivity. From the validation results, GC/SAW could serve as an alternative analytical technique for the analysis of volatile floral actual aroma of lilac. In addition, headspace solid-phase microextraction (HS-SPME) GC-MS was employed to further confirm the identification of fragrances emitted from lilac blossom and compared to GC/SAW.

  19. Intercomparison of the measurements of oxalic acid in aerosols by gas chromatography and ion chromatography

    NASA Astrophysics Data System (ADS)

    Kawamura, Kimitaka; Barrie, Leonard A.; Toom-Sauntry, Desiree

    2010-12-01

    Oxalate, the anion of oxalic acid, is one of the most abundant measurable organic species in atmospheric aerosols. Traditionally, this bifunctional species has been measured by gas chromatography (GC) after derivatization to butyl ester and by ion chromatography (IC) without derivatization. However, there are few published comparisons of the two techniques. Here, we report the results of an intercomparison study for the measurement of oxalic acid in Arctic aerosols (<2.5 μm, n = 82) collected in 1992 using GC and IC. The concentrations of oxalic acid by GC ranged from 6.5-59.1 ng m -3 (av. 26.0 ng m -3, median 26.2 ng m -3) whereas those by IC ranged from 6.6-52.1 ng m -3 (av. 26.6 ng m -3, median 25.4 ng m -3). They showed a good correlation ( r = 0.84) with a slope of 0.96. Thus, observations of oxalate obtained by GC employing dibutyl esters are almost equal to those by IC. Because the accuracy of oxalic acid by GC method largely depends on the method used, it is important to strictly examine the recovery in each study.

  20. Technical Note: Fast two-dimensional GC-MS with thermal extraction for anhydro-sugars in fine aerosols

    EPA Science Inventory

    A fast two-dimensional gas chromatography (GC-MS) method that uses heart-cutting and thermal extraction (TE) and requires no chemical derivatization is developed for the determination of anhydro-sugars in fine aerosols. Evaluation of the TE-GC-GC-MS method shows high average rela...

  1. Headspace gas chromatography with flame ionization detection (HS-GC-FID) for the determination of dissolved methane in wastewater.

    PubMed

    Beale, D J; Tjandraatmadja, G; Toifl, M; Goodman, N

    2014-01-01

    There is currently a need for a simple, accurate and reproducible method that quantifies the amount of dissolved methane in wastewater in order to realize the potential methane that can be recovered and account for any emissions. This paper presents such a method, using gas chromatography with flame ionization detection fitted with a GS-Gas PRO column coupled with a headspace auto sampler. A practical limit of detection for methane of 0.9 mg L(-1), with a retention time of 1.24 min, was obtained. It was found that the reproducibility and accuracy of the method increased significantly when samples were collected using an in-house constructed bailer sampling device and with the addition of 100 μL hydrochloric acid (HCl) and 25% sodium chloride (NaCl) and sonication for 30 min prior to analysis. Analysis of wastewater samples and wastewater sludge collected from a treatment facility were observed to range from 12.51 to 15.79 mg L(-1) (relative standard deviation (RSD) 8.1%) and 17.56 to 18.67 mg L(-1) (RSD 3.4%) respectively. The performance of this method was validated by repeatedly measuring a mid-level standard (n=8; 10 mg L(-1)), with an observed RSD of 4.6%.

  2. Metabolomic Strategies Involving Mass Spectrometry Combined with Liquid and Gas Chromatography.

    PubMed

    Lopes, Aline Soriano; Cruz, Elisa Castañeda Santa; Sussulini, Alessandra; Klassen, Aline

    2017-01-01

    Amongst all omics sciences, there is no doubt that metabolomics is undergoing the most important growth in the last decade. The advances in analytical techniques and data analysis tools are the main factors that make possible the development and establishment of metabolomics as a significant research field in systems biology. As metabolomic analysis demands high sensitivity for detecting metabolites present in low concentrations in biological samples, high-resolution power for identifying the metabolites and wide dynamic range to detect metabolites with variable concentrations in complex matrices, mass spectrometry is being the most extensively used analytical technique for fulfilling these requirements. Mass spectrometry alone can be used in a metabolomic analysis; however, some issues such as ion suppression may difficultate the quantification/identification of metabolites with lower concentrations or some metabolite classes that do not ionise as well as others. The best choice is coupling separation techniques, such as gas or liquid chromatography, to mass spectrometry, in order to improve the sensitivity and resolution power of the analysis, besides obtaining extra information (retention time) that facilitates the identification of the metabolites, especially when considering untargeted metabolomic strategies. In this chapter, the main aspects of mass spectrometry (MS), liquid chromatography (LC) and gas chromatography (GC) are discussed, and recent clinical applications of LC-MS and GC-MS are also presented.

  3. A rapid assay for the simultaneous determination of nicotine, cocaine and metabolites in meconium using disposable pipette extraction and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Mozaner Bordin, Dayanne C; Alves, Marcela N R; Cabrices, Oscar G; de Campos, Eduardo G; De Martinis, Bruno Spinosa

    2014-01-01

    Drug abuse by pregnant women is considered a serious public health problem worldwide. Meconium is the first excretion in newborns and has been used as an alternative matrix to evaluate in utero drug exposure. Solid phase extraction (SPE) is widely employed to prepare and clean up samples in the field of forensic analysis. Most SPE products require large volumes of solvent, which culminates in longer sample processing times and increased cost per sample. Disposable pipette extraction (DPX) tips have been used as an alternative to traditional SPE cartridges. They combine efficient and rapid extraction with reduced solvent consumption. The purpose of this study was to develop and validate a method to determine nicotine, cotinine, cocaine, benzoylecgonine, cocaethylene and methyl ester anhydroecgonine in meconium using DPX and gas chromatography-mass spectrometry (GC-MS). Validation results indicated that extraction efficiency ranged 50-98%, accuracy 92-106%, intra-assay precision 4-12% and inter-assay precision 6-12%. Linear calibration curves resulted in R(2) values >0.99, limits of detection ranged from 2.5 to 15 ng/g and the limit of quantitation from 10 to 20 ng/g. The DPX-GC-MS method was shown to selectively analyze trace concentrations of drugs in meconium samples. Finally, the developed and validated method was applied to 50 meconium samples.

  4. Fingerprinting Deepwater Horizon Oil in the northern Gulf of Mexico using biomarkers and Gas Chromatography-Triple Quadrupole Mass Spectrometry (GC/MS/MS)

    NASA Astrophysics Data System (ADS)

    Adhikari, P. L.; Overton, E. B.; Maiti, K.; Wong, R. L.

    2016-02-01

    Petroleum biomarkers such as hopanes, steranes, and triaromatic steroids are more persistent than alkanes and aromatic compounds. Thus, they are often used to track spilled oil in the environments and as a proxy for weathering processes. The present study utilizes water samples, suspended and sinking particles, and seafloor sediments collected during 2011-2013 from various locations of the northern Gulf of Mexico with wide range of contaminated oil for Deepwater Horizon (DWH) oil fingerprinting. The MC252 source oil along with the samples collected in this study were analyzed using a gas chromatography coupled with a triple quadrupole mass spectrometry (GC/MS/MS) in Multiple Reaction Monitoring (MRM) mode and the results were compared with results from commonly used GC/MS selective ion monitoring (SIM) method. The results indicate that the MRM method separates interfering ions from interfering compounds and can be a powerful analytical strategy for a reliable identification and determination of trace levels of biomarkers in complex matrices. Source indicators such as the MRM fragment ion chromatograms of the biomarkers and their diagnostic ratios in samples were compared with the MC252 source oil. The preliminary results show that the biomarkers were below detection limits in dissolved samples. However, in few particulate and seafloor sediment samples, primarily from the immediate vicinity of the Macondo wellhead, contained their patterns. The results also illustrate that these biomarker compounds have been weathered within 1-3 years following the oil spill, and their DWH oil signature in some of these samples reflects this weathering.

  5. Olfactory response of Anastrepha striata (Diptera: Tephritidae) to guava and sweet orange volatiles.

    PubMed

    Diaz-Santiz, Edvin; Rojas, Julio C; Cruz-López, Leopoldo; Hernández, Emilio; Malo, Edi A

    2016-10-01

    The behavioral responses of virgin and mated female Anastrepha striata Schiner (Diptera: Tephritidae) to guava (Psidium guajava L.) or sweet orange (Citrus sinensis L.) were evaluated separately using multilure traps in two-choice tests in field cages. The results showed that flies were more attracted to guava and sweet orange volatiles than to control (unbaited trap). The physiological state (virgin or mated) of females did not affect their attraction to the fruit volatiles. Combined analysis of gas chromatography coupled with electroantennography (GC-EAD) of volatile extracts of both fruits showed that 1 and 6 compounds from orange and guava, respectively elicited repeatable antennal responses from mated females. The EAD active compounds in guava volatile extracts were identified by gas chromatography-mass spectrometry (GC-MS) as ethyl butyrate, (Z)-3-hexenol, hexanol, ethyl hexanoate, hexyl acetate, and ethyl octanoate. Linalool was identified as the only antennal active compound in sweet orange extracts. In field cage tests, there were no significant differences between the number of mated flies captured by the traps baited with guava extracts and the number caught by traps baited with the 6-component blend that was formulated according to the relative proportions in the guava extracts. Similar results occurred when synthetic linalool was evaluated against orange extracts. From a practical point of view, the compounds identified in this study could be used for monitoring A. striata populations. © 2015 Institute of Zoology, Chinese Academy of Sciences.

  6. Selective and comprehensive analysis of organohalogen compounds by GC × GC-HRTofMS and MS/MS.

    PubMed

    Hashimoto, Shunji; Zushi, Yasuyuki; Takazawa, Yoshikatsu; Ieda, Teruyo; Fushimi, Akihiro; Tanabe, Kiyoshi; Shibata, Yasuyuki

    2018-03-01

    Thousands of organohalogen compounds, including hazardous chemicals such as polychlorinated biphenyls (PCBs) and other persistent organic pollutants (POPs), were selectively and simultaneously detected and identified with simple, or no, purification from environmental sample extracts by using several advanced methods. The methods used were software extraction from two-dimensional gas chromatography-high-resolution time-of-flight mass spectrometry (GC × GC-HRTofMS) data, measurement by negative chemical ionization with HRTofMS, and neutral loss scanning (NLS) with GC × GC-MS/MS. Global and selective detection of organochlorines and bromines in environmental samples such as sediments and fly ash was achieved by NLS using GC × GC-MS/MS (QQQ), with the expected losses of 35 Cl and 79 Br. We confirmed that negative chemical ionization was effective for sensitive and selective ionization of organohalogens, even using GC × GC-HRTofMS. The 2D total ion chromatograms obtained by using negative chemical ionization and selective extraction of organohalogens using original software from data measured by electron impact ionization were very similar; the software thus functioned well to extract organohalogens. Combining measurements made by using these different methods will help to detect organohalogens selectively and globally. However, to compare the data obtained by individual measurements, the retention times of the peaks on the 2D chromatograms need to match.

  7. Determination of cocaine and its derivatives in hair samples by liquid phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Pego, A M F; Roveri, F L; Kuninari, R Y; Leyton, V; Miziara, I D; Yonamine, M

    2017-05-01

    Hair testing is a recognized approach when it comes to accessing historical drug use. According to the World Drug Report of United Nations Office on Drugs and Crime (UNODC) 2015, Brazil is the largest cocaine (COC) market in South America. New analytical methodologies to detect crack/cocaine analytes in hair samples are highly desirable. Here, a method consisting of a liquid-phase microextraction (LPME) as a clean-up step, followed by gas chromatography-mass spectrometry (GC-MS) analysis has been proposed. The new validated method consisted of a washing step; an overnight incubation with methanol and a quick derivatization with butylchloroformate. Once derivatized, the samples were then submitted to the LPME procedure. Limits of detection (LoD) and quantitation (LoQ) obtained were of 0.1 and 0.5ng/mg for COC 0.4 and 0.5ng/mg for anhydroecgonine methyl ester (AEME); 0.03 and 0.05 for cocaethylene (CE), respectively and 0.05ng/mg for both LoD and LoQ for benzoylecgonine (BZE). All calibration curves were linear over the scope applied, from LoQ up to 20ng/mg, with a r 2 >0.99. Precision and accuracy assays showed acceptable %RSD values, according to international guidelines. Twelve postmortem head hair samples stemming from the Institute of Legal Medicine of Sao Paulo (IML-SP) have been analyzed, from which seven have shown to be positive for COC (0.75->20ng/mg) and BZE (0.1->20ng/mg). Apart from COC's main metabolite, four samples were also positive for CE (0.1-3.9ng/mg) and three samples for AEME (0.5-4.9ng/mg). To conclude, the LPME technique together with GC-MS analysis have shown promising results and were able to meet the demand of the laboratory of analyzing postmortem hair samples to look for all four analytes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Ethanol concentration in 56 refillable electronic cigarettes liquid formulations determined by headspace gas chromatography with flame ionization detector (HS-GC-FID).

    PubMed

    Poklis, Justin L; Wolf, Carl E; Peace, Michelle R

    2017-10-01

    Personal battery-powered vaporizers or electronic cigarettes were developed as an alternative to traditional cigarettes. The modern electronic cigarettes were patented in 2004 by Hon Lik in China. In May 2016, the US Food and Drug Administration (FDA) imposed regulatory statutes on e-cigarettes and their liquid formulations (e-liquids); prior to that, they were unregulated. E-liquids are typically composed of propylene glycol and/or glycerin, flavouring component(s), and active ingredient(s), such as nicotine. Fifty-six commercially available e-liquids, purchased from various sources, contained a variety of flavours and active ingredients. A headspace gas chromatography with flame ionization detector (HS-GC-FID) method was used to analyze these e-liquids for volatiles content. Only one of the e-liquids listed ethanol as a component. The chromatographic separation of volatiles was performed on a Restek BAC-1 column. A linear calibration was generated for ethanol with limits of detection and quantification (LOD/LOQ) of 0.05 mg/mL. Ethanol concentrations in the 56 e-liquids ranged from none detected to 206 mg/mL. The ethanol determined in these products may have been used in flavourants or a solvent; the reason for inclusion cannot be fully ascertained. The implications of vaporizing ethanol as an e-liquid component are unknown. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. The quantification of short-chain chlorinated paraffins in sediment samples using comprehensive two-dimensional gas chromatography with μECD detection.

    PubMed

    Muscalu, Alina M; Morse, Dave; Reiner, Eric J; Górecki, Tadeusz

    2017-03-01

    The analysis of persistent organic pollutants in environmental samples is a challenge due to the very large number of compounds with varying chemical and physical properties. Chlorinated paraffins (CPs) are complex mixtures of chlorinated n-alkanes with varying chain lengths (C 10 to C 30 ) and degree of chlorination (30 to 70% by weight). Their physical-chemical properties make these compounds persistent in the environment and able to bioaccumulate in living organisms. Comprehensive two-dimensional gas chromatography (GC × GC) coupled with micro-electron capture detection (μECD) was used to separate and quantify short-chain chlorinated paraffins (SCCP) in sediment samples. Distinct ordered bands were observed in the GC × GC chromatograms pointing to group separation. Using the Classification function of the ChromaTOF software, summary tables were generated to determine total area counts to set up multilevel-calibration curves for different technical mixes. Fortified sediment samples were analyzed by GC × GC-μECD with minimal extraction and cleanup. Recoveries ranged from 120 to 130%. To further validate the proposed method for the analysis of SCCPs, the laboratory participated in interlaboratory studies for the analysis of standards and sediment samples. The results showed recoveries between 75 and 95% and z-score values <2, demonstrating that the method is suitable for the analysis of SCCPs in soil/sediment samples. Graphical abstract Quantification of SCCPs by 2D-GC-μECD.

  10. An olfactory shift is associated with male perfume differentiation and species divergence in orchid bees.

    PubMed

    Eltz, Thomas; Zimmermann, Yvonne; Pfeiffer, Carolin; Pech, Jorge Ramirez; Twele, Robert; Francke, Wittko; Quezada-Euan, J Javier G; Lunau, Klaus

    2008-12-09

    Saltational changes may underlie the diversification of pheromone communication systems in insects, which are normally under stabilizing selection favoring high specificity in signals and signal perception. In orchid bees (Euglossini), the production of male signals depends on the sense of smell: males collect complex blends of volatiles (perfumes) from their environment, which are later emitted as pheromone analogs at mating sites. We analyzed the behavioral and antennal response to perfume components in two male morphotypes of Euglossa cf. viridissima from Mexico, which differ in the number of mandibular teeth. Tridentate males collected 2-hydroxy-6-nona-1,3-dienyl-benzaldehyde (HNDB) as the dominant component of their perfume. In bidentate males, blends were broadly similar but lacked HNDB. Population genetic analysis revealed that tri- and bidentate males belong to two reproductively isolated lineages. Electroantennogram tests (EAG and GC-EAD) showed substantially lower antennal responses to HNDB in bidentate versus tridentate males, revealing for the first time a mechanism by which closely related species acquire different chemical compounds from their habitat. The component-specific differences in perfume perception and collection in males of two sibling species are in agreement with a saltational, olfaction-driven mode of signal perfume evolution. However, the response of females to the diverged signals remains unknown.

  11. Rapid analysis of 3,4-methylenedioxymethamphetamine: a comparison of nonaqueous capillary electrophoresis/fluorescence detection with GC/MS.

    PubMed

    Fang, Ching; Chung, Yu-Lin; Liu, Ju-Tsung; Lin, Cheng-Huang

    2002-02-18

    Because of the increasing use of 3,4-methylenedioxymethamphetamine (3,4-MDMA), a rapid and sensitive analytical technique is required for its detection and determination. Using nonaqueous capillary electrophoresis/fluorescence spectroscopy (NACE/FS) detection, it is possible to determine this drug at the level 0.5 ppm without any pre-treatment in less than 5 min. After liquid-liquid extraction, the sample can be condensed and a detection limit of 3,4-MDMA in urine of 50 ppb (S/N = 3) can be achieved. The precision of the method was evaluated by measuring the repeatability and intermediate precision of migration time and the corrected peak height by comparison with a 3,4-MDMA-D5 internal standard. With the conventional GC/MS method, it is necessary to derivatize the 3,4-MDMA before injection and the GC migration time also is in excess of 20 min. Therefore, NACE/FS represents a good complementary method to GC/MS for use in forensic analysis.

  12. Comparison of an enzyme-linked immunosorbent assay (ELISA) to gas chromatography (GC) - measurement of polychlorinated biphenyls (PCBs) in selected US fish extracts

    USGS Publications Warehouse

    Zajicek, J.L.; Tillitt, D.E.; Schwartz, T.R.; Schmitt, C.J.; Harrison, R.O.

    2000-01-01

    The analysis of PCBs in fish tissues by immunoassay methods was evaluated using fish collected from a US monitoring program, the National Contaminant Biomonitoring Program of the US Department of Interior, Fish and Wildlife Service. Selected composite whole fish samples, which represented widely varying concentrations and sources of PCBs, were extracted and subjected to congener PCB analysis by gas chromatography (GC) and total PCB analysis using an ELISA (ePCBs) calibrated against technical Aroclor 1248. PCB congener patterns in these fishes were different from the patterns found in commercial Aroclors or their combinations as demonstrated by principal component analysis of normalized GC congener data. The sum of the PCB congeners measured by GC (total-PCBs) ranged from 37 to 4600 ng/g (wet weight). Concentrations of PCBs as determined by the ELISA method were positively correlated with total-PCBs and the ePCBs/total-PCBs ratios for individual samples ranged from 1 to 6. Ratios of ePCBs/total-PCBs for dilutions of Aroclors 1242, 1254, and 1260 and for matrix spikes range from 0.6 for 1242 to 2.5 for 1254 and 1260. These results suggest that higher chlorinated PCB congeners have higher affinity for the anti-PCB antibodies. Partial least squares with latent variable analysis of GC and ELISA data of selected Aroclors and fish samples also support the conclusion that ELISA derived PCB concentrations are dependent on the degree on chlorination.

  13. [Magnetic solid phase extraction combined with gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in juice samples].

    PubMed

    Huang, Qian; He, Man; Chen, Beibei; Hu, Bin

    2014-10-01

    A novel method for the determination of organophosphorous pesticides (OPPs) in fresh juice samples was developed. Fe3O4 @ P (St-co-MAA) magnetic microparticles were synthesized and modified with styrene (St) and methacrylic acid (MAA) by coating St and MAA on magnetic particles and characterized by a series of techniques. The results indicated that Fe3 O4 magnetic nanoparticles (MNPs) have been successfully modified with St and MAA. Based on the prepared FeO4 @ P (St-co-MAA) magnetic microparticles, a novel method of magnetic solid phase extraction (MSPE)-gas chromatography (GC)-flame photometric detection (FPD) was developed for the determination of OPPs. The extraction/desorption conditions of MSPE were optimized, and the analytical performance was evaluated under the optimal conditions. The limits of detection (LODs, S/N = 3) for target OPPs were in the range of 0.013-0.305 μg/L with the RSDs (n = 7) ranging from 3.1% to 8.8%. The enrichment factors varied from 406 to 951. The linear ranges were over three orders of magnitudes (R2 > 0.99) and the reproducibilities were 7.4%-14.5% (n = 5). Finally, the proposed MSPE-GC-FPD method was successfully applied to the analysis of the five OPPs in fresh tomato and strawberry juice samples, with the recoveries of target OPPs in the range of 85.4%-118.9% for the spiked samples. The proposed MSPE-GC-FPD method is featured with low cost, fast separation and high enrichment factor.

  14. HS-SPME-GC-FID method for detection and quantification of Bacillus cereus ATCC 10702 mediated 2-acetyl-1-pyrroline.

    PubMed

    Deshmukh, Yogita; Khare, Puja; Patra, D D; Nadaf, Altafhusain B

    2014-01-01

    A rapid micro-scale solid-phase micro-extraction (SPME) procedure coupled with gas-chromatography with flame ionized detector (GC-FID) was used to extract parts per billion levels of a principle basmati aroma compound "2-acetyl-1-pyrroline" (2-AP) from bacterial samples. In present investigation, optimization parameters of bacterial incubation period, sample weight, pre-incubation time, adsorption time, and temperature, precursors and their concentrations has been studied. In the optimized conditions, detection of 2-AP produced by Bacillus cereus ATCC10702 using only 0.5 g of sample volume was 85 μg/kg. Along with 2-AP, 15 other compounds produced by B. cereus were also reported out of which 14 were reported for the first time consisting mainly of (E)-2-hexenal, pentadecanal, 4-hydroxy-2-butanone, n-hexanal, 2-6-nonadienal, 3-methoxy-2(5H) furanone and 2-acetyl-1-pyridine and octanal. High recovery of 2-AP (87 %) from very less amount of B. cereus samples was observed. The method is reproducible fast and can be used for detection of 2-AP production by B. cereus. © 2014 American Institute of Chemical Engineers.

  15. Rapid gas chromatography with flame photometric detection of multiple organophosphorus pesticides in Salvia miltiorrhizae after ultrasonication assisted one-step extraction.

    PubMed

    Zhang, Shanshan; Liu, Xiaofei; Qin, Jia'an; Yang, Meihua; Zhao, Hongzheng; Wang, Yong; Guo, Weiying; Ma, Zhijie; Kong, Weijun

    2017-11-15

    A simple and rapid gas chromatography-flame photometric detection (GC-FPD) method was developed for the determination of 12 organophosphorus pesticides (OPPs) in Salvia miltiorrhizae by using ultrasonication assisted one-step extraction (USAE) without any clean-up steps. Some crucial parameters such as type of extraction solvent were optimized to improve the method performance for trace analysis. Any clean-up steps were negligent as no interferences were detected in the GC-FPD chromatograms for sensitive detection. Under the optimized conditions, limits of detection (LODs) and quantitation (LOQs) for all pesticides were in the range of 0.001-0.002mg/kg and 0.002-0.01mg/kg and 0.002-0.01mg/kg, respectively, which were all below the regulatory maximum residue limits suggested. RSDs for method precision (intra- and inter-day variations) were lower than 6.8% in approval with international regulations. Average recovery rates for all pesticides at three fortification levels (0.5, 1.0 and 5.0mg/kg) were in the range of 71.2-101.0% with relative standard deviations (RSDs) <13%. The developed method was evaluated for its feasibility in the simultaneous pre-concentration and determination of 12 OPPs in 32 batches of real S. miltiorrhizae samples. Only one pesticide (dimethoate) out of the 12 targets was simultaneously detected in four samples at concentrations of 0.016-0.02mg/kg. Dichlorvos and omethoate were found in the same sample from Sichuan province at 0.004 and 0.027mg/kg, respectively. Malathion and monocrotophos were determined in the other two samples at 0.014 and 0.028mg/kg, respectively. All the positive samples were confirmed by LC-MS/MS. The simple, reliable and rapid USAE-GC-FPD method with many advantages over traditional techniques would be preferred for trace analysis of multiple pesticides in more complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples

    PubMed Central

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-01-01

    Background: Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. Materials and Methods: We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. Results: AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Conclusions: Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations. PMID:22558586

  17. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples.

    PubMed

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-09-01

    Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.

  18. Sensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart Opiate Microplate EIA and GC-MS following controlled codeine administration.

    PubMed

    Barnes, Allan J; Kim, Insook; Schepers, Raf; Moolchan, Eric T; Wilson, Lisa; Cooper, Gail; Reid, Claire; Hand, Chris; Huestis, Marilyn A

    2003-10-01

    Oral fluid specimens (N = 1406) were collected from 19 subjects prior to and up to 72 h following controlled administration of oral codeine. Volunteers provided informed consent to participate in this National Institute on Drug Abuse Institutional Review Board-approved protocol. A modification of Cozart Microplate Opiate EIA Oral Fluid Kit (Opiate ELISA), employing codeine calibrators, was used for semiquantitative analysis of opiates, followed by gas chromatography-mass spectrometry (GC-MS) for the confirmation and quantitation of codeine, norcodeine, morphine, and normorphine in oral fluid. GC-MS limits of detection and quantitation were 2.5 microg/L for all analytes. The Substance Abuse and Mental Health Services Administration (SAMHSA) has proposed a 40-microg/L opiate screening and a 40-microg/L morphine or codeine confirmation cutoff for the detection of opiate use. Oral fluid opiate screening and confirmation cutoffs of 30 micro g/L are in use in the U.K. Utilizing 2.5-, 20-, 30-, and 40-microg/L GC-MS cutoffs, 26%, 20%, 19%, and 18% of the oral fluid specimens were positive for codeine or one of its metabolites. Six Opiate ELISA/confirmation cutoff criteria (2.5/2.5, 10/2.5, 20/20, 30/20, 30/30, and 40/40 microg/L) were evaluated. Calculations for Opiate ELISA sensitivity, specificity, and efficiency were determined from the number of true-positive, true-negative, false-positive, and false-negative results at each screening/confirmation cutoff. Sensitivity, specificity, and efficiency for the lowest cutoff were 91.5%, 88.6%, and 89.3%. Application of the cutoff currently used in the U.K. yielded sensitivity, specificity, and efficiency results of 79.7%, 99.0%, and 95.4% and similar results of 76.7%, 99.1%, and 95.1% when applying the SAMHSA criteria. These data indicate that the Opiate ELISA efficiently detects oral codeine use. In addition, the data, collected following controlled oral codeine administration, may aid in the interpretation of opiate oral

  19. Performance of the future MOMA GC-ITMS instrument

    NASA Astrophysics Data System (ADS)

    Grand, Noel; Buch, Arnaud; Veronica, Pinnick; Szopa, Cyril; Danell, Ryan; Van Amerom, Friso H. W.; Glavin, Daniel P.; Freissinet, Caroline; Arevalo, Ricardo; Stalport, Fabien; Getty, Stephanie; Coll, Patrice; Steinninger, Harald; Brinckerhoff, William; Mahaffy, Paul; Goesmann, Fred; Raulin, F.; Goetz, Walter; MOMA Team

    2016-10-01

    The Mars Organic Molecule Analyzer (MOMA) experiment aboard the future ExoMars mission will be the continuation of the SAM expirement aboard the Curiosity rover, with the search for the organic composition of the Mars surface. With ExoMars the sample will be extracted as deep as 2 meters below the martian surface to minimize effects of radiation and oxidation on organic materials. To analyze the wide range of organic composition (volatile and non-volatiles compounds) of the Martian soil MOMA is composed with an UV laser desorption / ionization (LDI) and a pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS). In order to analyze refractory organic compounds and chirality samples which undergo GC-ITMS analysis may be submitted to a derivatization process, consisting of the reaction of the sample components with specific reactants (MTBSTFA [1], DMF-DMA [2] or TMAH [3]).To optimize and test the performance of the GC-ITMS instrument we have performed several coupling tests campaigns between the GC, providing by the French team (LISA, LATMOS, CentraleSupelec), and the MS, providing by the US team (NASA, GSFC). Last campaign has been done with the ETU models which is similar to the flight model and which include the oven and the taping station providing by the German team (MPS).The results obtained demonstrate the current status of the end-to-end performance of the gas chromatography-mass spectrometry mode of operation.

  20. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors.

    PubMed

    Liu, Jing; Gupta, Naveen K; Wise, Kensall D; Gianchandani, Yogesh B; Fan, Xudong

    2011-10-21

    This paper reports the investigation of a micro-gas chromatographyGC) system that utilizes an array of miniaturized motionless Knudsen pumps (KPs) as well as microfabricated separation columns and optical detectors. A prototype system was built to achieve a flow rate of 1 mL min(-1) and 0.26 mL min(-1) for helium and dry air, respectively, when they were used as carrier gas. This system was then employed to evaluate GC performance compromises and demonstrate the ability to separate and detect gas mixtures containing analytes of different volatilities and polarities. Furthermore, the use of pressure programming of the KP array was demonstrated to significantly shorten the analysis time while maintaining a high detection resolution. Using this method, we obtained a high resolution detection of 5 alkanes of different volatilities within 5 min. Finally, we successfully detected gas mixtures of various polarities using a tandem-column μGC configuration by installing two on-column optical detectors to obtain complementary chromatograms.

  1. Efficient approach for the detection and identification of new androgenic metabolites by applying SRM GC-CI-MS/MS: a methandienone case study.

    PubMed

    Polet, Michael; Van Gansbeke, Wim; Van Eenoo, Peter; Deventer, Koen

    2016-07-01

    Identification of anabolic androgenic steroids (AAS) is a vital issue in doping control and toxicology, and searching for metabolites with longer detection times remains an important task. Recently, a gas chromatography chemical ionization triple quadrupole mass spectrometry (GC-CI-MS/MS) method was introduced, and CI, in comparison with electron ionization (EI), proved to be capable of increasing the sensitivity significantly. In addition, correlations between AAS structure and fragmentation behavior could be revealed. This enables the search for previously unknown but expected metabolites by selection of their predicted transitions. The combination of both factors allows the setup of an efficient approach to search for new metabolites. The approach uses selected reaction monitoring which is inherently more sensitive than full scan or precursor ion scan. Additionally, structural information obtained from the structure specific CI fragmentation pattern facilitates metabolite identification. The procedure was demonstrated by a methandienone case study. Its metabolites have been studied extensively in the past, and this allowed an adequate evaluation of the efficiency of the approach. Thirty three metabolites were detected, including all relevant previously discovered metabolites. In our study, the previously reported long-term metabolite (18-nor-17β-hydroxymethyl,17α-methyl-androst-1,4,13-trien-3-one) could be detected up to 26 days by using GC-CI-MS/MS. The study proves the validity of the approach to search for metabolites of new synthetic AAS and new long-term metabolites of less studied AAS and illustrates the increase in sensitivity by using CI. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. IDENTIFICATION OF BIS(2-CHLOROETHYL) ETHER HYDROLYSIS PRODUCTS BY DIRECT AQUEOUS INJECTION GC/FT-IR

    EPA Science Inventory

    Gas chromatography coupled to Fourier-transform infrared spectroscopy (GC/FT-IR) is rapidly becoming an accepted analytical technique complementary to GC/mass spectroscopy for identifying organic compounds in mixtures at low to moderate concentrations. irect aqueous injection (DA...

  3. Simultaneous determination of methanol, acetaldehyde, acetone, and ethanol in human blood by gas chromatography with flame ionization detection.

    PubMed

    Schlatter, J; Chiadmi, F; Gandon, V; Chariot, P

    2014-01-01

    Methanol, acetaldehyde, acetone, and ethanol, which are commonly used as biomarkers of several diseases, in acute intoxications, and forensic settings, can be detected and quantified in biological fluids. Gas chromatography (GC)-mass spectrometry techniques are complex, require highly trained personnel and expensive materials. Gas chromatographic determinations of ethanol, methanol, and acetone have been reported in one study with suboptimal accuracy. Our objective was to improve the assessment of these compounds in human blood using GC with flame ionization detection. An amount of 50 µl of blood was diluted with 300 µl of sterile water, 40 µl of 10% sodium tungstate, and 20 µl of 1% sulphuric acid. After centrifugation, 1 µl of the supernatant was injected into the gas chromatograph. We used a dimethylpolysiloxane capillary column of 30 m × 0.25 mm × 0.25 µm. We observed linear correlations from 7.5 to 240 mg/l for methanol, acetaldehyde, and acetone and from 75 to 2400 mg/l for ethanol. Precision at concentrations 15, 60, and 120 mg/l for methanol, acetaldehyde, and acetone and 150, 600, and 1200 mg/ml for ethanol were 0.8-6.9%. Ranges of accuracy were 94.7-98.9% for methanol, 91.2-97.4% for acetaldehyde, 96.1-98.7% for acetone, and 105.5-111.6% for ethanol. Limits of detection were 0.80 mg/l for methanol, 0.61 mg/l for acetaldehyde, 0.58 mg/l for acetone, and 0.53 mg/l for ethanol. This method is suitable for routine clinical and forensic practices.

  4. Alkaloids Profiling of Fumaria capreolata by Analytical Platforms Based on the Hyphenation of Gas Chromatography and Liquid Chromatography with Quadrupole-Time-of-Flight Mass Spectrometry.

    PubMed

    Contreras, María Del Mar; Bribi, Noureddine; Gómez-Caravaca, Ana María; Gálvez, Julio; Segura-Carretero, Antonio

    2017-01-01

    Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata . The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market.

  5. Alkaloids Profiling of Fumaria capreolata by Analytical Platforms Based on the Hyphenation of Gas Chromatography and Liquid Chromatography with Quadrupole-Time-of-Flight Mass Spectrometry

    PubMed Central

    Bribi, Noureddine; Gómez-Caravaca, Ana María

    2017-01-01

    Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata. The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market. PMID:29348751

  6. Evaluation of ionic liquid stationary phases for one dimensional gas chromatography-mass spectrometry and comprehensive two dimensional gas chromatographic analyses of fatty acids in marine biota.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Vanormelingen, Pieter; Vyverman, Wim; Rumpel, Klaus; Xu, Guowang; Sandra, Pat

    2011-05-20

    Ionic liquid stationary phases were tested for one dimensional gas chromatography-mass spectrometry (GC-MS) and comprehensive two dimensional gas chromatography (GC×GC) of fatty acid methyl esters from algae. In comparison with polyethylene glycol and cyanopropyl substituted polar stationary phases, ionic liquid stationary phases SLB-IL 82 and SLB-IL 100 showed comparable resolution, but lower column bleeding with MS detection, resulting in better sensitivity. The selectivity and polarity of the ionic liquid phases are similar to a highly polar biscyanopropyl-silicone phase (e.g. HP-88). In GC×GC, using an apolar polydimethyl siloxane×polar ionic liquid column combination, an excellent group-type separation of fatty acids with different carbon numbers and number of unsaturations was obtained, providing information that is complementary to GC-MS identification. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Metal-organic frameworks in chromatography.

    PubMed

    Yusuf, Kareem; Aqel, Ahmad; ALOthman, Zeid

    2014-06-27

    Metal-organic frameworks (MOFs) emerged approximately two decades ago and are the youngest class of porous materials. Despite their short existence, MOFs are finding applications in a variety of fields because of their outstanding chemical and physical properties. This review article focuses on the applications of MOFs in chromatography, including high-performance liquid chromatography (HPLC), gas chromatography (GC), and other chromatographic techniques. The use of MOFs in chromatography has already had a significant impact; however, the utilisation of MOFs in chromatography is still less common than other applications, and the number of MOF materials explored in chromatography applications is limited. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Separation and Detection of Toxic Gases with a Silicon Micromachined Gas Chromatography System

    NASA Technical Reports Server (NTRS)

    Kolesar, Edward S.; Reston, Rocky R.

    1995-01-01

    A miniature gas chromatography (GC) system was designed and fabricated using silicon micromachining and integrated circuit (IC) processing techniques. The silicon micromachined gas chromatography system (SMGCS) is composed of a miniature sample injector that incorporates a 10 microliter sample loop; a 0.9 meter long, rectangular shaped (300 micrometer width and 10 micrometer height) capillary column coated with a 0.2 micrometer thick copper phthalocyanine (CuPc) stationary phase; and a dual detector scheme based upon a CuPc-coated chemiresistor and a commercially available 125 micrometer diameter thermal conductivity detector (TCD) bead. Silicon micromachining was employed to fabricate the interface between the sample injector and the GC column, the column itself, and the dual detector cavity. A novel IC thin-film processing technique was developed to sublime the CuPc stationary phase coating on the column walls that were micromachined in the host silicon wafer substrate and Pyrex (r) cover plate, which were then electrostatically bonded together. The SMGCS can separate binary gas mixtures composed of parts-per-million (ppm) concentrations of ammonia (NH3) and nitrogen dioxide (NO2) when isothermally operated (55-80 degrees C). With a helium carrier gas and nitrogen diluent, a 10 microliter sample volume containing ammonia and nitrogen dioxide injected at 40 psi ((2.8 x 10(exp 5)Pa)) can be separated in less than 30 minutes.

  9. Trace analysis of impurities in bulk gases by gas chromatography-pulsed discharge helium ionization detection with "heart-cutting" technique.

    PubMed

    Weijun, Yao

    2007-10-12

    A method has been developed for the detection of low-nL/L-level impurities in bulk gases such as H(2), O(2), Ar, N(2), He, methane, ethylene and propylene, respectively. The solution presented here is based upon gas chromatography-pulsed discharge helium ionization detection (GC-PDHID) coupled with three two-position valves, one two-way solenoid valve and four packed columns. During the operation, the moisture and heavy compounds are first back-flushed via a pre-column. Then the trace impurities (except CO(2) which is diverted to a separate analytical column for separation and detection) together with the matrix enter onto a main column, followed by the heart-cut of the impurities onto a longer analytical column for complete separation. Finally the detection is performed by PDHID. This method has been applied to different bulk gases and the applicability of detecting impurities in H(2), Ar, and N(2) are herewith demonstrated. As an example, the resulting detection limit of 100 nL/L and a dynamic range of 100-1000 nL/L have been obtained using an Ar sample containing methane.

  10. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Hladik, Michelle; Smalling, Kelly L.; Kuivila, Kathryn

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  11. Selective determination of semi-volatile thiophene compounds in water by molecularly imprinted polymer thin films with direct headspace gas chromatography sulfur chemiluminescence detection.

    PubMed

    Hijazi, Hassan Y; Bottaro, Christina S

    2018-02-26

    Water-compatible molecularly imprinted polymer (MIP) thin films are coupled with headspace gas chromatography sulfur chemiluminescence detection (HS-GC-SCD) to create a new approach for the determination of trace concentrations of thiophene compounds in water samples. Thiophene compounds are persistent, typically petrogenic, organic pollutants of concern due to their potential for biomagnification and bioaccumulation, mutagenicity, and carcinogenicity in terrestrial and aquatic fauna. Identification and quantitation in water, particularly following oil spills, is a priority. Following adsorption of the thiophenes to the MIPs, the MIP-bound analytes are analyzed directly by HS-GC-SCD, with minimal sample manipulation and virtually no organic solvent. Calibration curves of spiked seawater were linear from 5 μg L -1 to 100 μg L -1 and limits of detection (LOD) were in the range of 0.24-0.82 μg L -1 . Low matrix effects were observed in the analysis of thiophene compounds in seawater making the method suitable for use in fresh and saline waters without modification. Acceptable reproducibility was obtained for analysis of thiophene compounds from spiked seawater samples at RSDs ≤7.0% (n = 3).

  12. Comprehensive two-dimensional gas chromatography applied to illicit drug analysis.

    PubMed

    Mitrevski, Blagoj; Wynne, Paul; Marriott, Philip J

    2011-11-01

    Multidimensional gas chromatography (MDGC), and especially its latest incarnation--comprehensive two-dimensional gas chromatography (GC × GC)--have proved advantageous over and above classic one-dimensional gas chromatography (1D GC) in many areas of analysis by offering improved peak capacity, often enhanced sensitivity and, especially in the case of GC × GC, the unique feature of 'structured' chromatograms. This article reviews recent advances in MDGC and GC × GC in drug analysis with special focus on ecstasy, heroin and cocaine profiling. Although 1D GC is still the method of choice for drug profiling in most laboratories because of its simplicity and instrument availability, GC × GC is a tempting proposition for this purpose because of its ability to generate a higher net information content. Effluent refocusing due to the modulation (compression) process, combined with the separation on two 'orthogonal' columns, results in more components being well resolved and therefore being analytically and statistically useful to the profile. The spread of the components in the two-dimensional plots is strongly dependent on the extent of retention 'orthogonality' (i.e. the extent to which the two phases possess different or independent retention mechanisms towards sample constituents) between the two columns. The benefits of 'information-driven' drug profiling, where more points of reference are usually required for sample differentiation, are discussed. In addition, several limitations in application of MDGC in drug profiling, including data acquisition rate, column temperature limit, column phase orthogonality and chiral separation, are considered and discussed. Although the review focuses on the articles published in the last decade, a brief chronological preview of the profiling methods used throughout the last three decades is given.

  13. Methods for the analysis of organophosphorus flame retardants-Comparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS.

    PubMed

    Tokumura, Masahiro; Miyake, Yuichi; Wang, Qi; Nakayama, Hayato; Amagai, Takashi; Ogo, Sayaka; Kume, Kazunari; Kobayashi, Takeshi; Takasu, Shinji; Ogawa, Kumiko

    2018-04-16

    Organophosphorus flame retardants (PFRs) are extensively used as alternatives to banned polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). In this study, we analyzed 14 PFRs by means of four mass-spectrometry-based methods: gas chromatography combined with electron-impact mass spectrometry (GC-EI-MS) or negative-chemical-ionization mass spectrometry (GC-NCI-MS) and liquid chromatography combined with tandem mass spectrometry using electrospray ionization (LC-ESI-MS/MS) or atmospheric pressure chemical ionization (LC-APCI-MS/MS). The limits of quantification (LOQs) for LC-ESI-MS/MS and LC-APCI-MS/MS (0.81-970 pg) were 1-2 orders of magnitude lower than the LOQs for GC-EI-MS and GC-NCI-MS (2.3-3900 pg). LC-APCI-MS/MS showed the lowest LOQs (mean = 41 pg; median = 3.4 pg) for all but two of the PFRs targeted in this study. For LC-APCI-MS/MS, the lowest LOQ was observed for tributyl phosphate (TBP) (0.81 pg), and the highest was observed for tris(butoxyethyl) phosphate (TBOEP) (36 pg). The results of this study indicate that LC-APCI-MS/MS is the optimum analytical method for the target PFRs, at least in terms of LOQ.

  14. Two-dimensional on-line detection of brominated and iodinated volatile organic compounds by ECD and ICP-MS after GC separation.

    PubMed

    Schwarz, A; Heumann, K G

    2002-09-01

    Inductively coupled plasma-mass spectrometry (ICP-MS) was coupled to a gas chromatographic (GC) system with electron capture detector (ECD), which enables relatively easy characterization and quantification of brominated and iodinated (halogenated) volatile organic compounds (HVOCs) in aquatic and air samples. The GC-ECD system is connected in series with an ICP-MS by a directly heated transfer line and an outlet port-hole for elimination of the ECD make-up gas during ignition of the plasma. The hyphenated GC-ECD/ICP-MS system provides high selectivity and sensitivity for monitoring individual HVOCs under fast chromatographic conditions. The ECD is most sensitive for the detection of chlorinated and brominated but the ICP-MS for iodinated compounds. The greatest advantage of the use of an ICP-MS is its element-specific detection, which allows clear identification of compounds in most cases. The absolute detection limits for ICP-MS are 0.5 pg for iodinated, 10 pg for brominated, and 50 pg for chlorinated HVOCs with the additional advantage that calibration is almost independent on different compounds of the same halogen. In contrast to that detection limits for ECD vary for the different halogenated compounds and lie in the range of 0.03-11 pg. The two-dimensional GC-ECD/ICP-MS instrumentation is compared with electron impact mass spectrometry (EI-MS) and microwave induced plasma atomic emission detection (MIP-AED). Even if EI-MS has additional power in identifying unknown peaks by its scan mode, the detection limits are much higher compared with GC-ECD/ICP-MS, whereas the selective ion monitoring mode (SIM) reaches similar detection limits. The MIP-AED detection limits are at the same level as EI-MS in the scan mode.

  15. Application of Sensory Evaluation, HS-SPME GC-MS, E-Nose, and E-Tongue for Quality Detection in Citrus Fruits.

    PubMed

    Qiu, Shanshan; Wang, Jun

    2015-10-01

    In this study, electronic tongue (E-tongue), headspace solid-phase microextraction gas chromatography-mass spectrometer (GC-MS), electronic nose (E-nose), and quantitative describe analysis (QDA) were applied to describe the 2 types of citrus fruits (Satsuma mandarins [Citrus unshiu Marc.] and sweet oranges [Citrus sinensis {L.} Osbeck]) and their mixing juices systematically and comprehensively. As some aroma components or some flavor molecules interacted with the whole juice matrix, the changes of most components in the fruit juice were not in proportion to the mixing ratio of the 2 citrus fruits. The potential correlations among the signals of E-tongue and E-nose, volatile components, and sensory attributes were analyzed by using analysis of variance partial least squares regression. The result showed that the variables from the sensor signals (E-tongue system and E-nose system) had significant and positive (or negative) correlations to the most variables of volatile components (GC-MS) and sensory attributes (QDA). The simultaneous utilization of E-tongue and E-nose obtained a perfect classification result with 100% accuracy rate based on linear discriminant analysis and also attained a satisfying prediction with high coefficient association for the sensory attributes (R(2) > 0.994 for training sets and R(2) > 0.983 for testing sets) and for the volatile components (R(2) > 0.992 for training sets and R(2) > 0.990 for testing sets) based on random forest. Being easy-to-use, cost-effective, robust, and capable of providing a fast analysis procedure, E-nose and E-tongue could be used as an alternative detection system to traditional analysis methods, such as GC-MS and sensory evaluation by human panel in the fruit industry. Being easy-to-use, cost-effective, robust, and capable of providing a fast analysis procedure, E-nose and E-tongue could be used as an alternative detection system to traditional analysis methods for characterizing food flavors. Based on those

  16. Vacuum ultraviolet detector for gas chromatography.

    PubMed

    Schug, Kevin A; Sawicki, Ian; Carlton, Doug D; Fan, Hui; McNair, Harold M; Nimmo, John P; Kroll, Peter; Smuts, Jonathan; Walsh, Phillip; Harrison, Dale

    2014-08-19

    Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120-240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer-Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3-4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.

  17. Olfaction in the boll weevil,Anthonomus grandis Boh. (Coleoptera: Curculionidae): Electroantennogram studies.

    PubMed

    Dickens, J C

    1984-12-01

    Electroantennogram (EAG) techniques were utilized to measure the antennal olfactory responsiveness of adult boll weevils,Anthonomus grandis Boh. (Coleoptera: Curculionidae), to 38 odorants, including both insect and host plant (Gossypium hirsutum L.) volatiles. EAGs of both sexes were indicative of at least two receptor populations: one receptor population primarily responsive to pheromone components and related compounds, the other receptor population primarily responsive to plant odors. Similar responses to male aggregation pheromone components (i.e., compounds I, II, and III + IV) were obtained from both sexes, but females were slightly more sensitive to I. Both sexes were highly responsive to components of the "green leaf volatile complex," especially the six-carbon saturated and monounsaturated primary alcohols. Heptanal was the most active aldehyde tested. More acceptors responded to oxygenated monoterpenes than to monoterpene hydrocarbons. β-Bisabolol, the major volatile of cotton, was the most active sesquiterpene. In general, males, which are responsible for host selection and pheromone production, were more sensitive to plant odors than were females. In fact, males were as sensitive to β-bisabolol and heptanal as to aggregation pheromone components. Electrophysiological data are discussed with regard to the role of insect and host plant volatiles in host selection and aggregation behavior of the boll weevil.

  18. Gas chromatography time-of-flight mass spectrometry (GC-TOF-MS)-based metabolomics for comparison of caffeinated and decaffeinated coffee and its implications for Alzheimer's disease.

    PubMed

    Chang, Kai Lun; Ho, Paul C

    2014-01-01

    Findings from epidemiology, preclinical and clinical studies indicate that consumption of coffee could have beneficial effects against dementia and Alzheimer's disease (AD). The benefits appear to come from caffeinated coffee, but not decaffeinated coffee or pure caffeine itself. Therefore, the objective of this study was to use metabolomics approach to delineate the discriminant metabolites between caffeinated and decaffeinated coffee, which could have contributed to the observed therapeutic benefits. Gas chromatography time-of-flight mass spectrometry (GC-TOF-MS)-based metabolomics approach was employed to characterize the metabolic differences between caffeinated and decaffeinated coffee. Orthogonal partial least squares discriminant analysis (OPLS-DA) showed distinct separation between the two types of coffee (cumulative Q(2) = 0.998). A total of 69 discriminant metabolites were identified based on the OPLS-DA model, with 37 and 32 metabolites detected to be higher in caffeinated and decaffeinated coffee, respectively. These metabolites include several benzoate and cinnamate-derived phenolic compounds, organic acids, sugar, fatty acids, and amino acids. Our study successfully established GC-TOF-MS based metabolomics approach as a highly robust tool in discriminant analysis between caffeinated and decaffeinated coffee samples. Discriminant metabolites identified in this study are biologically relevant and provide valuable insights into therapeutic research of coffee against AD. Our data also hint at possible involvement of gut microbial metabolism to enhance therapeutic potential of coffee components, which represents an interesting area for future research.

  19. Partial least squares analysis of rocket propulsion fuel data using diaphragm valve-based comprehensive two-dimensional gas chromatography coupled with flame ionization detection.

    PubMed

    Freye, Chris E; Fitz, Brian D; Billingsley, Matthew C; Synovec, Robert E

    2016-06-01

    The chemical composition and several physical properties of RP-1 fuels were studied using comprehensive two-dimensional (2D) gas chromatography (GC×GC) coupled with flame ionization detection (FID). A "reversed column" GC×GC configuration was implemented with a RTX-wax column on the first dimension ((1)D), and a RTX-1 as the second dimension ((2)D). Modulation was achieved using a high temperature diaphragm valve mounted directly in the oven. Using leave-one-out cross-validation (LOOCV), the summed GC×GC-FID signal of three compound-class selective 2D regions (alkanes, cycloalkanes, and aromatics) was regressed against previously measured ASTM derived values for these compound classes, yielding root mean square errors of cross validation (RMSECV) of 0.855, 0.734, and 0.530mass%, respectively. For comparison, using partial least squares (PLS) analysis with LOOCV, the GC×GC-FID signal of the entire 2D separations was regressed against the same ASTM values, yielding a linear trend for the three compound classes (alkanes, cycloalkanes, and aromatics), yielding RMSECV values of 1.52, 2.76, and 0.945 mass%, respectively. Additionally, a more detailed PLS analysis was undertaken of the compounds classes (n-alkanes, iso-alkanes, mono-, di-, and tri-cycloalkanes, and aromatics), and of physical properties previously determined by ASTM methods (such as net heat of combustion, hydrogen content, density, kinematic viscosity, sustained boiling temperature and vapor rise temperature). Results from these PLS studies using the relatively simple to use and inexpensive GC×GC-FID instrumental platform are compared to previously reported results using the GC×GC-TOFMS instrumental platform. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Southern pine beetle, Dendroctonus frontalis, antennal and behavioral responses to nonhost leaf and bark volatiles

    Treesearch

    William Shepherd; Brian Sullivan

    2013-01-01

    A growing body of evidence suggests that bark beetles detect and avoid release points of volatile compounds associated with nonhost species, and thus such nonhost volatiles may have potential utility in the management of bark beetles. We used a coupled gas chromatograph-electroantennographic detector (GC-EAD) to assay the olfactory sensitivity of the southern pine...

  1. Comparative chromatography-mass spectrometry studies on the antiretroviral drug nevirapine-analytical performance characteristics in human plasma determination.

    PubMed

    Sichilongo, Kwenga; Chinyama, Mompati; Massele, Amos; Vento, Sandro

    2014-01-15

    A contrast between the analytical performance characteristics using gas chromatography-mass spectrometry (GC-MS) liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-ultraviolet (LC-UV) detection for the determination of the antiretroviral drug (ARV) nevirapine (NVP) in fortified human plasma after QuEChERS extraction has been made. Analytical performance characteristics, i.e. linearities, instrument detection limits (IDLs), limits of quantitation (LOQs), method detection limits (MDLs), % mean recoveries and the corresponding relative standard deviations (%RSDs) were estimated using techniques above. Using GC-MS, the correlation coefficients (r(2)) were ≥0.990, which were deemed acceptable linearities. The MDLs ranged between 11.1-29.8μg/L and 13.7-36.0μg/L using helium and hydrogen carrier gases respectively. The LOQs ranged between 16.5-66.7μg/L and 28.4-98.7μg/L using helium and hydrogen carrier gases respectively with a % mean recovery of 83% and %RSD of 4.6%. Using LC-MS and LC-UV, the correlation coefficients (r(2)) were ≥0.990. The MDLs were ranged between 3.14 and 47.1μg/L. The LOQs ranged between 2.85 and 90.0μg/L respectively. The MDLs using GC-MS, LC-MS and LC-UV were below the therapeutic range for NVP in human plasma is considered to be between 2300μg/L (Cmin) and 8000μg/L (Cmax). This study also demonstrated that helium can be substituted with hydrogen which is relatively cheaper and easily obtainable even by use of a generator. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Modified Method for Detection of Benzoylecgonine in Human Urine by GC-MS: Derivatization Using Pentafluoropropanol/Acetic Anhydride.

    PubMed

    Serafin, Michelle C; Paulemon, Kasandra M; Fuller, Zachary J; Bronner, William E

    2017-05-01

    An existing GC-MS method for detecting benzoylecgonine (BZE) in urine was modified by changing derivatizing reagents. This method modification presents a cost-effective alternative derivatization procedure for the detection of BZE in urine by GC-MS. The combination of pentafluoropropanol and acetic anhydride was found to produce the same reaction product for BZE as pentafluoropropanol with pentafluoropropionic anhydride, while reducing reagent cost. With no anhydride present, derivatization of BZE by pentafluoropropanol did not occur. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  3. Applicability of solid-phase microextraction combined with gas chromatography atomic emission detection (GC-MIP AED) for the determination of butyltin compounds in sediment samples.

    PubMed

    Carpinteiro, J; Rodríguez, I; Cela, R

    2004-11-01

    The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid-liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED.

  4. Identification and deconvolution of carbohydrates with gas chromatography-vacuum ultraviolet spectroscopy.

    PubMed

    Schenk, Jamie; Nagy, Gabe; Pohl, Nicola L B; Leghissa, Allegra; Smuts, Jonathan; Schug, Kevin A

    2017-09-01

    Methodology for qualitative and quantitative determination of carbohydrates with gas chromatography coupled to vacuum ultraviolet detection (GC-VUV) is presented. Saccharides have been intently studied and are commonly analyzed by gas chromatography-mass spectrometry (GC-MS), but not always effectively. This can be attributed to their high degree of structural complexity: α/β anomers from their axial/equatorial hydroxyl group positioning at the C1-OH and flexible ring structures that lead to the open chain, five-membered ring furanose, and six-membered ring pyranose configurations. This complexity can result in convoluted chromatograms, ambiguous fragmentation patterns and, ultimately, analyte misidentification. In this study, mono-, di, and tri-saccharides were derivatized by two different methods-permethylation and oximation/pertrimethylsilylation-and analyzed by GC-VUV. These two derivatization methods were then compared for their efficiency, ease of use, and robustness. Permethylation proved to be a useful technique for the analysis of ketopentoses and pharmaceuticals soluble in dimethyl sulfoxide (DMSO), while the oximation/pertrimethylsilylation method prevailed as the more promising, overall, derivatization method. VUV spectra have been shown to be distinct and allow for efficient differentiation of isomeric species such as ketopentoses and reducing versus non-reducing sugars. In addition to identification, pharmaceutical samples containing several compounds were derivatized and analyzed for their sugar content with the GC-VUV technique to provide data for qualitative analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Detection of radiation-induced hydrocarbons in baked sponged cake prepared with irradiated liquid egg

    NASA Astrophysics Data System (ADS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K. W.; Schreiber, G. A.

    1995-02-01

    For identification of irradiated food, radiation-induced volatile hydrocarbons (HC) are determined by gas chromatography in the non-polar fraction of fat. However, in complex food matrices the detection is often disturbed by fat-associated compounds. On-line coupling of high performance liquid chromatography (LC) and gas chromatography (GC) is very efficient to remove such compounds from the HC fraction. The high sensitivity of this fast and efficient technique is demonstrated by the example of detection of radiation-induced HC in fat isolated from baked sponge cake which had been prepared with irradiated liquid egg.

  6. Confirmatory/release survey of the property at 71 Pearce Avenue (Former EAD Building) in Tonawanda, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salame-Alfie, A.; Alibozek, R.

    1995-12-31

    EAD Metallurgical, Inc., operated a facility in Tonawanda, New York, in which it utilized Americium 241 (Am-241) for the production of foil sources for use in smoke detectors. EAD was in operation between 1977 and 1983. By 1983, the company started losing money, and decided to relocate to Mexico. Before closing down its Tonawanda operation, however, it was required by the New York State Department of Labor (DOL) to decontaminate its facility to limits specified by DOL. No records of discharges to the sewer system were kept during this decontamination effort. Unsuccessful decontamination efforts by several EAD employees and contractorsmore » left the building contaminated, in particular the concrete floors and walls. To determine the scope of work for the decontamination project, staff from the New York State Departments of Health (DOH) and Environmental Conservation (DEC) conducted a Characterization Survey of the facility in 1993. This survey identified contamination levels of Am-241 in excess of release limits throughout the building, in the soil outside the facility, in pipes for sewage and interior drainage, and in an 8 x 8 x 11 foot sump pit in the building. DOH issued a request for proposals in early 1994 for the decontamination and subsequent decommissioning of the former EAD building, and NES/IES Inc. (NES) was awarded the contract to perform the remediation. DOH`s assignment was to provide an on-site presence to insure the completion of all agreed upon tasks, according to the terms of the contract and work plans submitted by NES. Additionally, the DOH staff acted as a liaison between NES, DOH, DEC and DOL central offices to review, comment and approve all changes or modifications to NES`s approach to the decontamination efforts. The assigned staff was also responsible for conducting confirmatory sampling and surveys of all areas deemed releasable to DOL and DEC criteria by NES.« less

  7. Multichannel Detection in High-Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    Miller, James C.; And Others

    1982-01-01

    A linear photodiode array is used as the photodetector element in a new ultraviolet-visible detection system for high-performance liquid chromatography (HPLC). Using a computer network, the system processes eight different chromatographic signals simultaneously in real-time and acquires spectra manually/automatically. Applications in fast HPLC…

  8. Hyphenated GC-FTIR and GC-MS techniques applied in the analysis of bioactive compounds

    NASA Astrophysics Data System (ADS)

    Gosav, Steluta; Paduraru, Nicoleta; Praisler, Mirela

    2014-08-01

    The drugs of abuse, which affect human nature and cause numerous crimes, have become a serious problem throughout the world. There are hundreds of amphetamine analogues on the black market. They consist of various alterations of the basic amphetamine molecular structure, which are yet not yet included in the lists of forbidden compounds although they retain or slightly modify the hallucinogenic effects of their parent compound. It is their important variety that makes their identification quite a challenge. A number of analytical procedures for the identification of amphetamines and their analogues have recently been reported. We are presenting the profile of the main hallucinogenic amphetamines obtained with the hyphenated techniques that are recommended for the identification of illicit amphetamines, i. e. gas chromatography combined with mass spectrometry (GC-MS) and gas chromatography coupled with Fourier transform infrared spectrometry (GC-FTIR). The infrared spectra of the analyzed hallucinogenic amphetamines present some absorption bands (1490 cm-1, 1440 cm-1, 1245 cm-1, 1050 cm-1 and 940 cm-1) that are very stable as position and shape, while their intensity depends of the side-chain substitution. The specific ionic fragment of the studied hallucinogenic compounds is the 3,4-methylenedioxybenzyl cation (m/e = 135) which has a small relative abundance (lesser than 20%). The complementarity of the above mentioned techniques for the identification of hallucinogenic compounds is discussed.

  9. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    PubMed

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Analysis of fatty acid ethyl esters in hair as possible markers of chronically elevated alcohol consumption by headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Pragst, F; Auwaerter, V; Sporkert, F; Spiegel, K

    2001-09-15

    Fatty acid ethyl esters (FAEE) are products of the nonoxidative ethanol metabolism, which are known to be detectable in blood only about 24h after the last alcohol intake. After deposition in hair they should be suitable long-term markers of chronically elevated alcohol consumption. Therefore, a method for the analysis of ethyl myristate, ethyl palmitate, ethyl oleate and ethyl stearate from hair was developed based on the extraction of the hair sample by a dimethylsulphoxide (DMSO)/n-hexane mixture, separation and evaporation of the n-hexane phase and application of headspace solid-phase microextraction (HS-SPME) in combination with gas chromatography-mass spectrometry (GC-MS) to the extract. For use as internal standards, the corresponding D(5)-ethyl esters were prepared. The HS-SPME/GC-MS measurements were automatically performed using a multi-purpose sampler. The detection limits of the FAEE were between 0.01 and 0.04ng/mg and the reproducibility was between 3.5 and 16%. By application of the method to hair samples of 21 fatalities with known heavy alcohol abuse 0.045-2.4ng/mg ethyl myristate, 0.35-13.5ng/mg ethyl palmitate, 0.25-7.7ng/mg ethyl oleate and 0.05-3.85ng/mg ethyl stearate were measured. For social drinkers (30-60g ethanol per week), the concentrations were about one order of magnitude smaller. For 10 teetotalers negative results or traces of ethyl palmitate were found. It was shown by supplementary investigations in single cases that FAEE are also present in sebum, that there is no strong difference in their concentrations between pubic, chest and scalp hair, and that they are detectable in hair segments after a 2 months period of abstinence. From the results follows that the measurement of FAEE concentrations in hair is a useful way for a retrospective detection of alcohol abuse.

  11. Exploring the fatty acids of vernix caseosa in form of their methyl esters by off-line coupling of non-aqueous reversed phase high performance liquid chromatography and gas chromatography coupled to mass spectrometry.

    PubMed

    Hauff, Simone; Vetter, Walter

    2010-12-24

    Vernix caseosa is a greasy biofilm formed on the skin of the human fetus in the last period of pregnancy. This matrix is known to contain a range of uncommon branched chain fatty acids. In this study, we studied the fatty acid composition of vernix caseosa by non-aqueous reversed phase high performance liquid chromatography (RP-HPLC) fractionation followed by gas chromatography-electron ionization mass spectrometry (GC/EI-MS) of the fractions. For this purpose the fatty acids from vernix caseosa were converted into the corresponding methyl esters. These were fractionated by non-aqueous RP-HPLC using three serially connected C(18)-columns and pure methanol as the eluent. Aliquots of the HPLC fractions were directly analyzed by GC/EI-MS in the selected ion monitoring mode. Data analysis and visualization were performed by the creation of a two dimensional (2D) contour plot, in which GC retention times were plotted against the HPLC fractions. Inspection of the plot resulted in the detection of 133 different fatty acids but only 16 of them contributed more than 1% to the total fatty acids detected. Identification was based on HPLC and GC retention data, GC/MS-SIM and full scan data, as well as plotting the logarithmic retention times against the longest straight carbon chain. In selected cases, aliquots of the HPLC fractions were hydrogenated or studied by means of the picolinyl esters. Using these techniques, the number of double bonds could be unequivocally assigned to all fatty acids. Moreover, the number of methyl branches, and in many cases the positions of methyl branches could be determined. The enantioselective analysis of chiral anteiso-fatty acids resulted in the dominance of the S-enantiomers. However, high proportions of R-a13:0, R-a15:0, and R-a17:1 were also detected while a17:0 was virtually S-enantiopure. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. A direct immersion solid-phase microextraction gas chromatography/mass spectrometry method for the simultaneous detection of levamisole and minor cocaine congeners in hair samples from chronic abusers.

    PubMed

    Fucci, Nadia; Gambelunghe, Cristiana; Aroni, Kyriaki; Rossi, Riccardo

    2014-12-01

    Because levamisole has been increasingly found as a component of illicit drugs, a robust method to detect its presence in hair samples is needed. However, no systematic research on the detection of levamisole in hair samples has been published. The method presented here uses direct immersion solid-phase microextraction coupled with gas chromatography and mass spectrometry (DI-SPME-GC/MS) to detect levamisole and minor cocaine congeners in hair samples using a single-extraction method. Fifty hair samples taken in the last 4 years were obtained from cocaine abusers, along with controls taken from drug-free volunteers. Sampling was performed using direct immersion with a 30-μm polydimethylsiloxane fused silica/stainless steel fiber. Calibration curves were prepared by adding known amounts of analytes and deuterated internal standards to the hair samples taken from drug-free volunteers. This study focused on the adulterant levamisole and some minor cocaine congeners (tropococaine, norcocaine, and cocaethylene). Levamisole was detected in 38% of the hair samples analyzed; its concentration ranged from 0.2 to 0.8 ng/mg. The limit of quantification and limit of detection for levamisole, tropococaine, norcocaine, and cocaine were 0.2 and 0.1 ng/mg, respectively. DI-SPME-GC/MS is a sensitive and specific method to detect the presence of levamisole and cocaine congeners in hair samples.

  13. Development of a headspace GC/MS analysis for carbonyl compounds (aldehydes and ketones) in household products after derivatization with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine.

    PubMed

    Sugaya, Naeko; Sakurai, Katsumi; Nakagawa, Tomoo; Onda, Nobuhiko; Onodera, Sukeo; Morita, Masatoshi; Tezuka, Masakatsu

    2004-05-01

    Carbonyl compounds (aldehydes and ketones) are suspected to be among the chemical compounds responsible for Sick Building Syndrome and Multiple Chemical Sensitivities. A headspace gas chromatography/mass spectrometry (GC/MS) analysis for these compounds was developed using derivatization of the compounds into volatile derivatives with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBOA). For GC/MS detection, two ionization modes including electron impact ionization (EI) and negative chemical ionization (NCI) were compared. The NCI mode seemed to be better because of its higher selectivity and sensitivity. This headspace GC/MS (NCI mode) was employed as analysis for aldehydes and ketones in materials (fiber products, adhesives, and printed materials). Formaldehyde was detected in the range of N.D. (not detected) to 39 microg/g; acetaldehyde, N.D. to 4.1 microg/g; propionaldehyde, N.D. to 1.0 microg/g; n-butyraldehyde, N.D. to 0.10 microg/g; and acetone, N.D. to 3.1 microg/g in the samples analyzed.

  14. Gas Chromatography Time-Of-Flight Mass Spectrometry (GC-TOF-MS)-Based Metabolomics for Comparison of Caffeinated and Decaffeinated Coffee and Its Implications for Alzheimer’s Disease

    PubMed Central

    Chang, Kai Lun; Ho, Paul C.

    2014-01-01

    Findings from epidemiology, preclinical and clinical studies indicate that consumption of coffee could have beneficial effects against dementia and Alzheimer’s disease (AD). The benefits appear to come from caffeinated coffee, but not decaffeinated coffee or pure caffeine itself. Therefore, the objective of this study was to use metabolomics approach to delineate the discriminant metabolites between caffeinated and decaffeinated coffee, which could have contributed to the observed therapeutic benefits. Gas chromatography time-of-flight mass spectrometry (GC-TOF-MS)-based metabolomics approach was employed to characterize the metabolic differences between caffeinated and decaffeinated coffee. Orthogonal partial least squares discriminant analysis (OPLS-DA) showed distinct separation between the two types of coffee (cumulative Q2 = 0.998). A total of 69 discriminant metabolites were identified based on the OPLS-DA model, with 37 and 32 metabolites detected to be higher in caffeinated and decaffeinated coffee, respectively. These metabolites include several benzoate and cinnamate-derived phenolic compounds, organic acids, sugar, fatty acids, and amino acids. Our study successfully established GC-TOF-MS based metabolomics approach as a highly robust tool in discriminant analysis between caffeinated and decaffeinated coffee samples. Discriminant metabolites identified in this study are biologically relevant and provide valuable insights into therapeutic research of coffee against AD. Our data also hint at possible involvement of gut microbial metabolism to enhance therapeutic potential of coffee components, which represents an interesting area for future research. PMID:25098597

  15. Rapid determination of residues of pesticides in honey by µGC-ECD and GC-MS/MS: Method validation and estimation of measurement uncertainty according to document No. SANCO/12571/2013.

    PubMed

    Paoloni, Angela; Alunni, Sabrina; Pelliccia, Alessandro; Pecorelli, Ivan

    2016-01-01

    A simple and straightforward method for simultaneous determination of residues of 13 pesticides in honey samples (acrinathrin, bifenthrin, bromopropylate, cyhalothrin-lambda, cypermethrin, chlorfenvinphos, chlorpyrifos, coumaphos, deltamethrin, fluvalinate-tau, malathion, permethrin and tetradifon) from different pesticide classes has been developed and validated. The analytical method provides dissolution of honey in water and an extraction of pesticide residues by n-Hexane followed by clean-up on a Florisil SPE column. The extract was evaporated and taken up by a solution of an injection internal standard (I-IS), ethion, and finally analyzed by capillary gas chromatography with electron capture detection (GC-µECD). Identification for qualitative purpose was conducted by gas chromatography with triple quadrupole mass spectrometer (GC-MS/MS). A matrix-matched calibration curve was performed for quantitative purposes by plotting the area ratio (analyte/I-IS) against concentration using a GC-µECD instrument. According to document No. SANCO/12571/2013, the method was validated by testing the following parameters: linearity, matrix effect, specificity, precision, trueness (bias) and measurement uncertainty. The analytical process was validated analyzing blank honey samples spiked at levels equal to and greater than 0.010 mg/kg (limit of quantification). All parameters were satisfactorily compared with the values established by document No. SANCO/12571/2013. The analytical performance was verified by participating in eight multi-residue proficiency tests organized by BIPEA, obtaining satisfactory z-scores in all 70 determinations. Measurement uncertainty was estimated according to the top-down approaches described in Appendix C of the SANCO document using the within-laboratory reproducibility relative standard deviation combined with laboratory bias using the proficiency test data.

  16. Application of the Reference Method Isotope Dilution Gas Chromatography Mass Spectrometry (ID/GC/MS) to Establish Metrological Traceability for Calibration and Control of Blood Glucose Test Systems

    PubMed Central

    Andreis, Elisabeth; Küllmer, Kai

    2014-01-01

    Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. PMID:24876614

  17. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    NASA Astrophysics Data System (ADS)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  18. DETECTION OF HIGH MOLECULAR WEIGHT ORGANIC TRACERS IN VEGETATION SMOKE SAMPLES BY HIGH-TEMPERATURE GAS CHROMATOGRAPHY-MASS SPECTROMETRY. (R823990)

    EPA Science Inventory

    High-temperature high-resolution gas chromatography
    (HTGC) is an established technique for the separation of
    complex mixtures of high molecular weight (HMW) compounds
    which do not elute when analyzed on conventional GC
    columns. The combination of this technique wit...

  19. Determination of musks and other fragrance compounds at ng/L levels using CLSA (closed loop stripping analysis) and GC/MS detection.

    PubMed

    Mitjans, D; Ventura, F

    2004-01-01

    Closed loop stripping analysis (CLSA), a suitable tool for the determination of volatile and semivolatile compounds at low trace levels (ng/l), has been used to determine and quantify seven selected musks and two fragrances (Acetyl cedrene and Amberonne). The obtained extracts are analyzed by high resolution gas chromatography coupled to mass spectrometry (GC/MS) operating in the SIM mode. Quality parameters such as limit of detection; matrix effects; precision expressed as repeatability and reproducibility relative standard deviations of the method and an estimation of the uncertainty have been evaluated. The method has been applied to the analysis of wastewater effluents, surface water and tap water from different places in Europe. All samples contained differents musks at ng/l levels with the polycyclic musks Galaxolide and Tonalide and both fragrances, Amberonne and Acetyl cedrene, being the most abundant. These results suggest the importance of studying and controlling the presence of these ubiquitous environmental compounds in water systems.

  20. Evaluation of volatiles from two subtropical strawberry cultivars using GC-olfactometry, GC-MS odor activity values, and sensory analysis

    USDA-ARS?s Scientific Manuscript database

    Flavor profiles of two Florida strawberry cultivars were determined using GC-olfactometry,GC-MS, odor activity values (OAVs) and sensory analysis. Thirty-six aroma active compounds were detected using GC-O. Thirty-four were identified. The major odor-active compounds in decreasing intensity were: me...

  1. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    PubMed

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  2. Detection and identification of carprofen and its in vivo metabolites in greyhound urine by capillary gas chromatography-mass spectrometry.

    PubMed

    Dumasia, M C; Ginn, A; Hyde, W; Peterson, J; Houghton, E

    2003-05-25

    Rimadyl (carprofen) was administered orally to the racing greyhound at a dose of 2.2 mg kg(-1). Following both alkaline and enzymatic hydrolysis, postadministration urine samples were extracted by mixed mode solid-phase extraction (SPE) cartridges to identify target analyte(s) for forensic screening and confirmatory analysis methods. The acidic isolates were derivatised as trimethylsilyl ethers (TMS) and analysed by gas chromatography-mass spectrometry (GC-MS). Carprofen and five phase I metabolites were identified. Positive ion electron ionisation (EI(+)) mass spectra of the TMS derivatives of carprofen and its metabolites show a diagnostic base peak at M(+)*. -117 corresponding to the loss of COO-Si-(CH(3))(3) group as a radical. GC-MS with positive ion ammonia chemical ionisation (CI(+)) of the compounds provided both derivatised molecular mass and some structural information. Deutromethylation-TMS derivatisation was used to distinguish between aromatic and aliphatic oxidations of carprofen. The drug is rapidly absorbed, extensively metabolised and excreted as phase II conjugates in urine. Carprofen, three aromatic hydroxy and a minor N-hydroxy metabolite were detected for up to 48 h. For samples collected between 2 and 8 h after administration, the concentration of total carprofen ranged between 200 and 490 ng ml(-1). The major metabolite, alpha-hydroxycarprofen was detected for over 72 h and therefore can also be used as a marker for the forensic screening of carprofen in greyhound urine.

  3. Coupled LC-GC techniques for the characterisation of polycyclic aromatic compounds in fuel materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Askey, S.A.; Holden, K.M.L.; Bartle, K.D.

    1995-12-31

    Exposure to polycyclic aromatic compounds (PAC) has long been identified as of considerable environmental concern. Originating from both natural and anthropogenic sources, many PAC exhibit significant carcinogenic and mutagenic properties. Multi-dimensional chromatographic techniques which provide separation by virtue of chemical class (group-type) or by molecular mass greatly simplifies the analysis of inherently complex fuel materials. In this study, on-line LC-GC techniques in which high resolution gas chromatography (HPLC) have been investigated. Comprehensive characterisation of fuel feedstocks and post-pyrolysis and combustion products was achieved by coupling LC-GC to low resolution ion trap mass spectrometry (ITD-MS) and atomic emission detection (AED). Themore » identification of PAC in diesel and coal materials, as well as urban air and diesel exhaust particulate extracts has provided valuable insight into the source, formation and distribution of such compounds pre- and post processing.« less

  4. Identification of Aroma-active Compounds in Essential Oil from Uncaria Hook by Gas Chromatography- Mass Spectrometry and Gas Chromatography-Olfactometry.

    PubMed

    Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo

    2015-01-01

    The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields.

  5. Enzymatic digestion and selective quantification of underivatised delta-9-tetrahydrocannabinol and cocaine in human hair using gas chromatography-mass spectrometry.

    PubMed

    Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P

    2012-01-01

    Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ(9)-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ(9)-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ(9)-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ(9)-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis.

  6. Enzymatic Digestion and Selective Quantification of Underivatised Delta-9-Tetrahydrocannabinol and Cocaine in Human Hair Using Gas Chromatography-Mass Spectrometry

    PubMed Central

    Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P.

    2012-01-01

    Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ9-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ9-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ9-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ9-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis. PMID:22567573

  7. Floral volatiles in a sapromyiophilous plant and their importance in attracting house fly pollinators.

    PubMed

    Zito, Pietro; Dötterl, Stefan; Sajeva, Maurizio

    2015-04-01

    Floral scent in sapromyiophilous plants often consists of complex blends with not only fetid (e.g., sulfides) but also sweet (e.g., terpenoids) volatile organic compounds, and a recent study suggests that both groups of compounds are involved in pollinator attraction. However, little is known about the number and identity of compounds involved in pollinator attraction in these deceptive plants that mimic breeding sites of fly pollinators. In the present paper, we studied flower volatiles of sapromyiophilous Periploca laevigata and their capability to elicit biological responses in one of the pollinator species, Musca domestica. Floral volatiles were collected by dynamic headspace and analyzed by gas chromatography/mass spectrometry (GC/MS), and electrophysiological (GC/EAD) and behavioral assays (two choice olfactometer) were conducted. In the floral scent of P. laevigata, we detected 44 compounds, of which indole, β-caryophyllene, and germacrene D, as well as dimethyl trisulfide, which was present in trace amounts, were electrophysiologically active in the antennae of M. domestica. However, when we evaluated in behavioral experiments the attractiveness of the electrophysiologically active compounds (complete mixture against partial mixtures or against single compounds), we found that indole was the only attractive compound for the flies.

  8. Diagnosis of gastroenterological diseases by metabolome analysis using gas chromatography-mass spectrometry.

    PubMed

    Yoshida, Masaru; Hatano, Naoya; Nishiumi, Shin; Irino, Yasuhiro; Izumi, Yoshihiro; Takenawa, Tadaomi; Azuma, Takeshi

    2012-01-01

    Recently, metabolome analysis has been increasingly applied to biomarker detection and disease diagnosis in medical studies. Metabolome analysis is a strategy for studying the characteristics and interactions of low molecular weight metabolites under a specific set of conditions and is performed using mass spectrometry and nuclear magnetic resonance spectroscopy. There is a strong possibility that changes in metabolite levels reflect the functional status of a cell because alterations in their levels occur downstream of DNA, RNA, and protein. Therefore, the metabolite profile of a cell is more likely to represent the current status of a cell than DNA, RNA, or protein. Thus, owing to the rapid development of mass spectrometry analytical techniques metabolome analysis is becoming an important experimental method in life sciences including the medical field. Here, we describe metabolome analysis using liquid chromatography-mass spectrometry, gas chromatography-mass spectrometry (GC-MS), capillary electrophoresis-mass spectrometry, and matrix assisted laser desorption ionization-mass spectrometry. Then, the findings of studies about GC-MS-based metabolome analysis of gastroenterological diseases are summarized, and our research results are also introduced. Finally, we discuss the realization of disease diagnosis by metabolome analysis. The development of metabolome analysis using mass spectrometry will aid the discovery of novel biomarkers, hopefully leading to the early detection of various diseases.

  9. Direct determination of acrylamide in potato chips by using headspace solid-phase microextraction coupled with gas chromatography-flame ionization detection.

    PubMed

    Ghiasvand, Ali Reza; Hajipour, Somayeh

    2016-01-01

    Acrylamide is a potentially toxic and carcinogenic substance present in many high-consumption foods. Recently, this matter has been placed in category of "reasonably anticipated to be a human carcinogen" by National Toxicology Program (NTP). Therefore, simple and cost-effective determination of acrylamide in food samples has attracted intense interest. The most reported techniques for this purpose are GC-MS and LC-MS, which are very expensive and available in few laboratories. In this research, for the first time, a rapid, easy and low-cost method is introduced for sensitive and precise determination of acrylamide in foodstuffs, using gas chromatography-flame ionization detection (GC-FID) system after its direct trapping in the upper atmosphere of samples by headspace solid-phase microextraction (HS-SPME). The effects of main experimental variables were studied and the optimized parameters were obtained as the type of fiber, carboxen/divinylbenzene/polydimethylsiloxane (CAR/DVB/PDMS); extraction time, 30 min; extraction temperature, 60°C; moisture content, 10 µL water per 1g of sample; desorption time, 2 min; and desorption temperature, 230°C. The linear calibration graph was obtained in the range of 0.77-50 µg g(-1), with regression coefficient of 0.998. The detection and quantification limits of the proposed method were 0.22 and 0.77 µg g(-1), respectively. The recoveries, for different food samples, were 79.6-95.7%. The repeatability of measurements, expressed as relative standard deviation (RSD), were found to be 4.1-8.0% (n=9). The proposed HS-SPME-GC-FID method was successfully carried out for quantifying of trace levels of acrylamide in some processed food products (chips and French fries), sold in open local markets. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Identification of the sex pheromone secreted by a nettle moth, Monema flavescens, using gas chromatography/fourier transform infrared spectroscopy.

    PubMed

    Shibasaki, Hiroshi; Yamamoto, Masanobu; Yan, Qi; Naka, Hideshi; Suzuki, Toshiro; Ando, Tetsu

    2013-03-01

    The nettle moth Monema flavescens (Limacodidae) is a defoliator of fruit trees, such as Chinese plum and persimmon. The larvae of this species have spines containing a poison that causes serious irritation and inflammation in humans. Coupled gas chromatography-electroantennogram detection and gas chromatography/mass spectrometry analyses of a crude pheromone extract, combined with derivatization, indicated that female moths produced 8-decen-1-ol and 7,9-decadien-1-ol at a ratio of approximately 9:1. The E configuration of the double bonds was assigned for both components from infrared spectra, recorded on a gas chromatograph/Fourier transform-infrared spectrophotometer equipped with a zinc selenide disk cooled to -30 °C. The monoenyl and dienyl alcohols had absorptions characteristic of E geometry at 966 and 951 cm(-1), respectively. A band chromatogram at 951 cm(-1) was useful for distinguishing geometric isomers, because terminal conjugated diene are difficult to resolve, even on high polarity columns. Furthermore, we identified the Z configuration of the same 7,9-dienyl alcohol secreted by another nettle moth, Parasa lepida lepida, through the absence of this absorption. In field trials, lures baited with a 9:1 mixture of (E)-8-decen-1-ol and (E)-7,9-decadien-1-ol attracted M. flavescens males. Furthermore, the field trials indicated that contamination with the (Z)-diene reduced catches to the pheromone mixture more than did contamination with the (Z)-monoene.

  11. Benchmarking of candidate detectors for multiresidue analysis of pesticides by comprehensive two-dimensional gas chromatography.

    PubMed

    Engel, Erwan; Ratel, Jérémy; Blinet, Patrick; Chin, Sung-Tong; Rose, Gavin; Marriott, Philip J

    2013-10-11

    The present study discusses the relevance, performance and complementarities of flame photometric detector in phosphorus (FPD/P) and sulfur (FPD/S) modes, micro electron capture detector (μECD), nitrogen phosphorus detector (NPD), flame ionization detector (FID) and time-of-flight mass spectrometer (TOF/MS) for the comprehensive two-dimensional gas chromatography (GC×GC) analysis of pesticides. A mix of 41 pesticides including organophosphorus pesticides, synthetic pyrethroids and fungicides was investigated in order to benchmark GC×GC systems in terms of linearity (R(2)), limits of detection (LOD), and peak shape measures (widths and asymmetries). A mixture of pesticides which contained the heteroatoms phosphorus, sulfur, nitrogen and one or several halogens, was used to acquire a comparative data set to monitor relative detector performances. GC×GC datasets were systematically compared to their GC counterpart acquired with an optimized one-dimensional GC configuration. Compared with FID, considered the most appropriate detector in terms of suitability for GC×GC, the element-selective detector FPD/P and μECD best met the peak widths (0.13-0.27s for FPD/P; 0.22-0.26s for μECD) and tailing factors (0.99-1.66 for FPD/P; 1.32-1.52 for μECD); NPD exhibited similar peak widths (0.23-0.30s), but exceeded those of the above detectors for tailing factors (1.97-2.13). These three detectors had improved detection limits of 3-7 times and 4-20 times lower LODs in GC×GC mode compared with FID and TOF-MS, respectively. In contrast FPD/S had poor peak shape (tailing factor 3.36-5.12) and much lower sensitivity (10-20 fold lower compared to FPD/P). In general, element-selective detectors with favorable detection metrics can be considered viable alternatives for pesticide determination using GC×GC in complex matrices. The controversial issue of sensitivity enhancement in GC×GC was considered for optimized GC and GC×GC operation. For all detectors, we found no

  12. Development of a gas chromatography method for the determination of isotretinoin and its degradation products in pharmaceuticals.

    PubMed

    Lima, Eliana Martins; Diniz, Danielle G Almeida; Antoniosi-Filho, Nelson R

    2005-07-15

    This paper describes the development of a gas chromatography (GC) method used for the assay of isotretinoin in its isolated form and in pharmaceutical formulations. Isotretinoin soft and hard gelatin capsules were prepared with various excipients. The performance of the proposed gas chromatography method was compared to that of traditional high performance liquid chromatography (HPLC) systems for this substance, and the GC parameters were established based on several preliminary tests, including thermal analysis of isotretinoin. Results showed that gas chromatography-flame ionization detector (GC-FID) exhibited a separation efficiency superior to that of HPLC, particularly for separating isotretinoin degradation products. This method was proven to be effectively applicable to stability evaluation assays of isotretinoin and isotretinoin based pharmaceuticals.

  13. A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients

    PubMed Central

    Al-Khayat, Mohammad Ammar; Karabet, Francois; Al-Mardini, Mohammad Amer

    2018-01-01

    Formaldehyde is a highly reactive impurity that can be found in many pharmaceutical excipients. Trace levels of this impurity may affect drug product stability, safety, efficacy, and performance. A static headspace gas chromatographic method was developed and validated to determine formaldehyde in pharmaceutical excipients after an effective derivatization procedure using acidified ethanol. Diethoxymethane, the derivative of formaldehyde, was then directly analyzed by GC-FID. Despite the simplicity of the developed method, however, it is characterized by its specificity, accuracy, and precision. The limits of detection and quantification of formaldehyde in the samples were of 2.44 and 8.12 µg/g, respectively. This method is characterized by using simple and economic GC-FID technique instead of MS detection, and it is successfully used to analyze formaldehyde in commonly used pharmaceutical excipients. PMID:29686930

  14. Method for detection of extremely low concentration

    DOEpatents

    Andresen, Brian D.; Miller, Fred S.

    2002-01-01

    An ultratrace detector system for hand-held gas chromatography having high sensitivity, for example, to emissions generated during production of weapons, biological compounds, drugs, etc. The detector system is insensitive to water, air, helium, argon, oxygen, and CO.sub.2. The detector system is basically composed of a hand-held capillary gas chromatography (GC), an insulated heated redox-chamber, a detection chamber, and a vapor trap. For example, the detector system may use gas phase redox reactions and spectral absorption of mercury vapor. The gas chromatograph initially separates compounds that percolate through a bed of heated mercuric oxide (HgO) in a silica--or other metal--aerogel material which acts as an insulator. Compounds easily oxidized by HgO liberate atomic mercury that subsequently pass through a detection chamber which includes a detector cell, such as quartz, that is illuminated with a 254 nm ultra-violet (UV) mercury discharge lamp which generates the exact mercury absorption bands that are used to detect the liberated mercury atoms. Atomic mercury strongly absorbs 254 nm energy is therefore a specific signal for reducing compounds eluting from the capillary GC, whereafter the atomic mercury is trapped for example, in a silicon-aerogel trap.

  15. A Helium GC/IMS for the Analysis of Extraterrestrial Volatiles in Exobiology Flight Experiments

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Carle, Glenn C.; Humphry, Donald E.; Shao, Maxine; Takeuchi, Nori

    1995-01-01

    For exobiology experiments on board spacecraft or space probes, a wide range of chemical species often must be detected and identified. The limited amount of power and space available for flight instruments severely limits the number of instruments that can be flown on any given mission. It is important then, that these experiments utilize instrumentation with universal response, so that all species of interest can be analyzed. Instrumentation to fulfill the analytical requirements of exobiology experiments has been developed utilizing Gas Chromatography - Ion Mobility Spectrometry. The Gas Chromatograph (GC) combines columns developed specifically for the complex mixtures anticipated with highly sensitive Metastable Ionization Detectors (a type of Helium Ionization Detector). To satisfy the limitations placed on resources, the Ion Mobility Spectrometer (IMS) uses the same ultra high purity helium as the GC. This GC-MS provides the analytical capability to fulfill a wide range of exobiology flight experiment applications and has been included on a proposed Discovery Mission and proposals for both Lander and Orbiter of the European Space Agency's Rosetta Comet Mission. A data base of helium IMS spectra is now being built for these future applications.

  16. Online Continuous Trace Process Analytics Using Multiplexing Gas Chromatography.

    PubMed

    Wunsch, Marco R; Lehnig, Rudolf; Trapp, Oliver

    2017-04-04

    The analysis of impurities at a trace level in chemical products, nutrition additives, and drugs is highly important to guarantee safe products suitable for consumption. However, trace analysis in the presence of a dominating component can be a challenging task because of noncompatible linear detection ranges or strong signal overlap that suppresses the signal of interest. Here, we developed a technique for quantitative analysis using multiplexing gas chromatography (mpGC) for continuous and completely automated process trace analytics exemplified for the analysis of a CO 2 stream in a production plant for detection of benzene, toluene, ethylbenzene, and the three structural isomers of xylene (BTEX) in the concentration range of 0-10 ppb. Additional minor components are methane and methanol with concentrations up to 100 ppm. The sample is injected up to 512 times according to a pseudorandom binary sequence (PRBS) with a mean frequency of 0.1 Hz into a gas chromatograph equipped with a flame ionization detector (FID). A superimposed chromatogram is recorded which is deconvoluted into an averaged chromatogram with Hadamard transformation. Novel algorithms to maintain the data acquisition rate of the detector by application of Hadamard transformation and to suppress correlation noise induced by components with much higher concentrations than the target substances are shown. Compared to conventional GC-FID, the signal-to-noise ratio has been increased by a factor of 10 with mpGC-FID. Correspondingly, the detection limits for BTEX in CO 2 have been lowered from 10 to 1 ppb each. This has been achieved despite the presence of detectable components (methane and methanol) with a concentration about 1000 times higher than the target substances. The robustness and reliability of mpGC has been proven in a two-month field test in a chemical production plant.

  17. Detection of fenspiride and identification of in vivo metabolites in horse body fluids by capillary gas chromatography-mass spectrometry: administration, biotransformation and urinary excretion after a single oral dose.

    PubMed

    Dumasia, M C; Houghton, E; Hyde, W; Greulich, D; Nelson, T; Peterson, Jackie

    2002-02-05

    Studies related to the in vivo biotransforrmation and urinary excretion of fenspiride hydrochloride in the horse are described. After oral administration, the drug is metabolised by both phase I functionalisation and phase II conjugation pathways. Following enzymatic deconjugation, fenspiride and its phase I metabolites were isolated from post-administration biofluids using bonded co-polymeric mixed mode solid-phase extraction cartridges to isolate the basic compounds. Following trimethylsilylation (TMS), the parent drug and metabolites were identified by capillary gas chromatography-mass spectrometry (GC-MS). Fenspiride (A) and seven metabolites (B-->G) arising from oxidation on both the aromatic and heterocyclic substructures were detected in urine. The positive ion electron ionisation mass spectra of the TMS derivatives of fenspiride and its metabolites provided useful information on its metabolism. Positive ion methane chemical ionisation-GC-MS of the derivatives provided both derivatised molecular mass and structural information. Unchanged fenspiride can be detected in post-administration plasma and urine samples for up to 24 h. Maximum urinary levels of 100-200 ng ml(-1) were observed between 3 and 5 h after administration. After enzymatic deconjugation, the major phenolic metabolite (G) can be detected in urine for up to 72 h. This metabolite is the analyte of choice in the GC-MS screening of post-race equine urine samples for detection of fenspiride use. However, a distinct difference was observed in the urinary excretion of this metabolite between the thoroughbred horses used in UK study and the quarterbred and standardbred horses used for the USA administrations.

  18. [Simultaneous determination of nine preservatives in fruits using gas chromatography-mass spectrometry].

    PubMed

    Peng, Shunü; Wang, Qiuquan; Fang, Lanlan; Guo, Shanyong; Zeng, Zhouhua; Lin, Zhuguang

    2014-01-01

    A gas chromatography-mass spectrometry (GC-MS) method was established for the simultaneous determination of nine typical preservatives (pyrimethanil, chlorothalonil, chlorpyrifos, triadimefon, thiabendazole, imazalil, myclobutanil, iprodione, prochloraz) in fruits. The fruit samples were subjected to ultrasonic extraction with hexane/ethyl acetate (1/1, v/v), and followed by purification using diatomite column chromatography with hexane/ethyl acetate (1/3, v/v) eluant. Qualitative and quantitative analysis of the nine preservatives were performed on the GC-MS at full-scan (SCAN) and selected ion monitoring (SIM) modes, in which triphenylphosphate was used as the internal standard. The detection limits obtained for the nine preservatives were ranged from 0.10 microg/kg to 2.16 microg/kg. The average recoveries were in the range of 75.3% to 128% at the spiked levels of 50, 100 and 200 microg/kg with the relative standard deviations (RSDs) of 1.57% to 11.6% (n = 5). The results showed that the developed method is sensitive and accurate for the determination of the nine preservatives in fruits.

  19. Main differences between volatiles of sparkling and base wines accessed through comprehensive two dimensional gas chromatography with time-of-flight mass spectrometric detection and chemometric tools.

    PubMed

    Welke, Juliane Elisa; Zanus, Mauro; Lazzarotto, Marcelo; Pulgati, Fernando Hepp; Zini, Cláudia Alcaraz

    2014-12-01

    The main changes in the volatile profile of base wines and their corresponding sparkling wines produced by traditional method were evaluated and investigated for the first time using headspace solid-phase microextraction combined with comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detection (GC×GC/TOFMS) and chemometric tools. Fisher ratios helped to find the 119 analytes that were responsible for the main differences between base and sparkling wines and principal component analysis explained 93.1% of the total variance related to the selected 78 compounds. It was also possible to observe five subclusters in base wines and four subclusters in sparkling wines samples through hierarchical cluster analysis, which seemed to have an organised distribution according to the regions where the wines came from. Twenty of the most important volatile compounds co-eluted with other components and separation of some of them was possible due to GC×GC/TOFMS performance. Copyright © 2014. Published by Elsevier Ltd.

  20. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates.

    PubMed

    Moerdijk-Poortvliet, Tanja C W; Schierbeek, Henk; Houtekamer, Marco; van Engeland, Tom; Derrien, Delphine; Stal, Lucas J; Boschker, Henricus T S

    2015-07-15

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although LC/IRMS is expected to be more accurate and precise, no direct comparison has been reported. GC/IRMS with the aldonitrile penta-acetate (ANPA) derivatisation method was compared with LC/IRMS without derivatisation. A large number of glucose standards and a variety of natural samples were analysed for five neutral carbohydrates at natural abundance as well as at (13)C-enriched levels. Gas chromatography/chemical ionisation mass spectrometry (GC/CIMS) was applied to check for incomplete derivatisation of the carbohydrate, which would impair the accuracy of the GC/IRMS method. The LC/IRMS technique provided excellent precision (±0.08‰ and ±3.1‰ at natural abundance and enrichment levels, respectively) for the glucose standards and this technique proved to be superior to GC/IRMS (±0.62‰ and ±19.8‰ at natural abundance and enrichment levels, respectively). For GC/IRMS measurements the derivatisation correction and the conversion of carbohydrates into CO2 had a considerable effect on the measured δ(13)C values. However, we did not find any significant differences in the accuracy of the two techniques over the full range of natural δ(13)C abundances and (13)C-labelled glucose. The difference in the performance of GC/IRMS and LC/IRMS diminished when the δ(13)C values were measured in natural samples, because the chromatographic performance and background correction became critical factors, particularly for LC/IRMS. The derivatisation of carbohydrates for the GC/IRMS method was complete. Although both LC/IRMS and GC/IRMS are reliable techniques for compound-specific stable carbon isotope analysis of carbohydrates (provided that derivatisation is complete and the

  1. A NEW SW-846 METHOD FOR THE ANALYSIS OF TOXAPHENE AND TOXAPHENE CONGENERS IN SOLID AND AQUEOUS SAMPLES USING GAS CHROMATOGRAPHY / NEGATIVE ION MASS SPECTROMETRY

    EPA Science Inventory

    US EPA SW-846 methods have typically relied on dual column gas chromatography coupled with electron capture detection (GC-ECD) for analysis of low concentrations of organochlorine pesticides, including toxaphene, in environmental samples. Toxaphene is one of the most widely appl...

  2. Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

    PubMed Central

    Fazeli-Bakhtiyari, Rana; Panahi-Azar, Vahid; Sorouraddin, Mohammad Hossein; Jouyban, Abolghasem

    2015-01-01

    Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0; concentration of NaCl, 4% (w/v)), resulting in a cloudy solution. After centrifugation (6000 rpm for 6 min), an aliquot (1 µl) of the sedimented organic phase was removed using a 1-µl GC microsyringe and injected into the GC system for analysis. One variable at a time optimization method was used to study various parameters affecting the extraction efficiency of target analyte. Then, the developed method was fully validated for its accuracy, precision, recovery, stability, and robustness. Results: Under the optimum extraction conditions, good linearity range was obtained for the calibration graph, with correlation coefficient higher than 0.998. Limit of detection and lower limit of quantitation were 3.2 and 6 μg/ml, respectively. The relative standard deviations of intra and inter-day analysis of examined compound were less than 11.5%. The relative recoveries were found in the range of 97 to 107.5%. Finally, the validated method was successfully applied to the analysis of VPA in patient sample. Conclusion: The presented method has acceptable levels of precision, accuracy and relative recovery and could be used for therapeutic drug monitoring of VPA in human plasma. PMID:26730332

  3. The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography.

    PubMed

    Seeley, John V; Schimmel, Nicolaas E; Seeley, Stacy K

    2018-02-09

    A fluidic device called the multi-mode modulator (MMM) has been developed for use as a comprehensive two-dimensional gas chromatography (GC x GC) modulator. The MMM can be employed in a wide range of capacities including as a traditional heart-cutting device, a low duty cycle GC x GC modulator, and a full transfer GC x GC modulator. The MMM is capable of producing narrow component pulses (widths <50ms) while operating at flows compatible with high resolution chromatography. The sample path of modulated components is confined to the interior of a joining capillary. The joining capillary dimensions and the position of the columns within the joining capillary can be optimized for the selected modulation mode. Furthermore, the joining capillary can be replaced easily and inexpensively if it becomes fouled due to sample matrix components or column bleed. The principles of operation of the MMM are described and its efficacy is demonstrated as a heart-cutting device and as a GC x GC modulator. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Development of a supercritical fluid chromatography method with ultraviolet and mass spectrometry detection for the characterization of biomass fast pyrolysis bio oils.

    PubMed

    Crepier, Julien; Le Masle, Agnès; Charon, Nadège; Albrieux, Florian; Heinisch, Sabine

    2017-08-11

    The characterization of complex mixtures is a challenging issue for the development of innovative processes dedicated to biofuels and bio-products production. The huge number of compounds present in biomass fast pyrolysis oils combined with the large diversity of chemical functions represent a bottleneck as regards analytical technique development. For the extensive characterization of complex samples, supercritical fluid chromatography (SFC) can be alternative to usual separation techniques such as gas (GC) or liquid chromatography (LC). In this study, an approach is proposed to define the best conditions for the SFC separation of a fast pyrolysis bio-oil. This approach was based on SFC data obtained directly from the bio-oil itself instead of selecting model compounds as usually done. SFC conditions were optimized by using three specific, easy-to-use and quantitative criteria aiming at maximizing the separation power. Polar stationary phases (ethylpyridine bonded silica) associated to a mix of acetonitrile and water as polarity modifier provided the best results, with more than 120 peaks detected in SFC-UV. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simultaneous identification and quantification of new psychoactive substances in blood by GC-APCI-QTOFMS coupled to nitrogen chemiluminescence detection without authentic reference standards.

    PubMed

    Ojanperä, Ilkka; Mesihää, Samuel; Rasanen, Ilpo; Pelander, Anna; Ketola, Raimo A

    2016-05-01

    A novel platform is introduced for simultaneous identification and quantification of new psychoactive substances (NPS) in blood matrix, without the necessity of using authentic reference standards. The instrumentation consisted of gas chromatography (GC) coupled to nitrogen chemiluminescence detection (NCD) and atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (APCI-QTOFMS). In this concept, the GC flow is divided in appropriate proportions between NCD for single-calibrant quantification, utilizing the detector's equimolar response to nitrogen, and QTOFMS for accurate mass-based identification. The principle was proven by analyzing five NPS, bupropion, desoxypipradrol (2-DPMP), mephedrone, methylone, and naphyrone, in sheep blood. The samples were spiked with the analytes post-extraction to avoid recovery considerations at this point. All the NPS studies produced a protonated molecule in APCI resulting in predictable fragmentation with high mass accuracy. The N-equimolarity of quantification by NCD was investigated by using external calibration with the secondary standard caffeine at five concentration levels between 0.17 and 1.7 mg/L in blood matrix as five replicates. The equimolarity was on average 98.7%, and the range of individual equimolarity determinations was 76.7-130.1%. The current analysis platform affords a promising approach to instant simultaneous qualitative and quantitative analysis of drugs in the absence of authentic reference standards, not only in forensic and clinical toxicology but also in other bioanalytical applications.

  6. Analysis of ketamine and norketamine in urine by automatic solid-phase extraction (SPE) and positive ion chemical ionization-gas chromatography-mass spectrometry (PCI-GC-MS).

    PubMed

    Kim, Eun-mi; Lee, Ju-seon; Choi, Sang-kil; Lim, Mi-ae; Chung, Hee-sun

    2008-01-30

    Ketamine (KT) is widely abused for hallucination and also misused as a "date-rape" drug in recent years. An analytical method using positive ion chemical ionization-gas chromatography-mass spectrometry (PCI-GC-MS) with an automatic solid-phase extraction (SPE) apparatus was studied for the determination of KT and its major metabolite, norketamine (NK), in urine. Six ketamine suspected urine samples were provided by the police. For the research of KT metabolism, KT was administered to SD rats by i.p. at a single dose of 5, 10 and 20mg/kg, respectively, and urine samples were collected 24, 48 and 72 h after administration. For the detection of KT and NK, urine samples were extracted on an automatic SPE apparatus (RapidTrace, Zymark) with mixed mode type cartridge, Drug-Clean (200 mg, Alltech). The identification of KT and NK was by PCI-GC-MS. m/z238 (M+1), 220 for KT, m/z 224 (M+1), 207 for NK and m/z307 (M+1) for Cocaine-D(3) as internal standard were extracted from the full-scan mass spectrum and the underlined ions were used for quantitation. Extracted calibration curves were linear from 50 to 1000 ng/mL for KT and NK with correlation coefficients exceeding 0.99. The limit of detection (LOD) was 25 ng/mL for KT and NK. The limit of quantitation (LOQ) was 50 ng/mL for KT and NK. The recoveries of KT and NK at three different concentrations (86, 430 and 860 ng/mL) were 53.1 to 79.7% and 45.7 to 83.0%, respectively. The intra- and inter-day run precisions (CV) for KT and NK were less than 15.0%, and the accuracies (bias) for KT and NK were also less than 15% at the three different concentration levels (86, 430 and 860 ng/mL). The analytical method was also applied to real six KT suspected urine specimens and KT administered rat urines, and the concentrations of KT and NK were determined. Dehydronorketamine (DHNK) was also confirmed in these urine samples, however the concentration of DHNK was not calculated. SPE is simple, and needs less organic solvent than liquid

  7. DETERMINATION OF A BOUND MUSK XYLENE METABOLITE IN CARP HEMOGLOBIN AS A BIOMARKER OF EXPOSURE BY GAS CHROMATOGRAPHY MASS SPECTROMETRY USING SELECTED ION MONITORING

    EPA Science Inventory

    Musk xylene (MX) is widely used as a fragrance ingredient in commercial toiletries. Identification and quantification of a bound 4-amino-MX (AMX) metabolite was carried out by gas chromatography-mass spectrometry (GC/MS), with selected ion monitoring (SIM). Detection of AMX occur...

  8. Rapid evaluation technique to differentiate mushroom disease-related moulds by detecting microbial volatile organic compounds using HS-SPME-GC-MS.

    PubMed

    Radványi, Dalma; Gere, Attila; Jókai, Zsuzsa; Fodor, Péter

    2015-01-01

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was used to analyse microbial volatile organic compounds (MVOCs) of mushroom disease-related microorganisms. Mycogone perniciosa, Lecanicillum fungicola var. fungicola, and Trichoderma aggressivum f. europaeum species, which are typically harmful in mushroom cultivation, were examined, and Agaricus bisporus (bisporic button mushroom) was also examined as a control. For internal standard, a mixture of alkanes was used; these were introduced as the memory effect of primed septa in the vial seal. Several different marker compounds were found in each sample, which enabled us to distinguish the different moulds and the mushroom mycelium from each other. Monitoring of marker compounds enabled us to investigate the behaviour of moulds. The records of the temporal pattern changes were used to produce partial least squares regression (PLS-R) models that enabled determination of the exact time of contamination (the infection time of the media). Using these evaluation techniques, the presence of mushroom disease-related fungi can be easily detected and monitored via their emitted MVOCs.

  9. Quantitative analysis of arbutin and hydroquinone in strawberry tree (Arbutus unedo L., Ericaceae) leaves by gas chromatography-mass spectrometry.

    PubMed

    Jurica, Karlo; Karačonji, Irena Brčić; Šegan, Sandra; Opsenica, Dušanka Milojković; Kremer, Dario

    2015-09-01

    The phenolic glycoside arbutin and its metabolite with uroantiseptic activity hydroquinone occur naturally in the leaves of various medicinal plants and spices. In this study, an extraction procedure coupled with gas chromatography-mass spectrometry (GC-MS) was developed to determine arbutin and hydroquinone content in strawberry tree (Arbutus unedo L., Ericaceae) leaves. The method showed good linearity (R2>0.9987) in the tested concentration range (0.5-200 μg mL(-1)), as well as good precision (RSD<5%), analytical recovery (96.2-98.0%), and sensitivity (limit of detection=0.009 and 0.004 μg mL(-1) for arbutin and hydroquinone, respectively). The results obtained by the validated GC-MS method corresponded well to those obtained by high performance liquid chromatography (HPLC) method. The proposed method was then applied for determining arbutin and hydroquinone content in methanolic leaf extracts. The amount of arbutin in the leaves collected on the island of Koločep (6.82 mg g(-1) dry weight) was found to be higher (tpaired=43.57, tc=2.92) in comparison to the amount of arbutin in the leaves collected on the island of Mali Lošinj (2.75 mg g(-1) dry weight). Hydroquinone was not detected in any of the samples. The analytical features of the proposed GC-MS method demonstrated that arbutin and hydroquinone could be determined alternatively by gas chromatography. Due to its wide concentration range, the method could also be suitable for arbutin and hydroquinone analysis in leaves of other plant families (Rosaceae, Lamiaceae, etc.).

  10. Investigation of Pinus mugo essential oil oxygenated fraction by combined use of gas chromatography and dry column chromatography.

    PubMed

    A, M B; Coran, S A; Giannellini, V; Vincieri, F F; Moneti, G

    1981-09-01

    The oxygenated compounds of Pinus mugo Turra essential oil were investigated by a combination of GC and dry column chromatography (DCC) coordinated by GC data processing. The collected data resulted in a bar graph ("normalized" gas chromatogram) giving the RRT's and relative amounts of 68 components; 38 of them were identified by MS and IR. The described procedure may be used for essential oil analysis in general.

  11. Exhaust Air Dust Monitoring is Superior to Soiled Bedding Sentinels for the Detection of Pasteurella pneumotropica in Individually Ventilated Cage Systems.

    PubMed

    Miller, Manuel; Ritter, Brbel; Zorn, Julia; Brielmeier, Markus

    2016-11-01

    Reliable detection of unwanted organisms is essential for meaningful health monitoring in experimental animal facilities. Currently, most rodents are housed in IVC systems, which prevent the aerogenic transmission of pathogens between cages. Typically soiled-bedding sentinels (SBS) exposed to soiled bedding collected from a population of animals within an IVC rack are tested as representatives, but infectious agents often go undetected due to inefficient transmission. Pasteurellaceae are among the most prevalent bacterial pathogens isolated from experimental mice, and the failure of SBS to detect these bacteria is well established. In this study, we investigated whether analysis of exhaust air dust (EAD) samples by using a sensitive and specific real-time PCR assay is superior to conventional SBS monitoring for the detection of Pasteurella pneumotropica (Pp) infections. In a rack with a known prevalence of Pp-positive mice, weekly EAD sampling was compared with the classic SBS method over 3 mo. In 6 rounds of testing, with a prevalence of 5 infected mice in each of 7 cages in a rack of 63 cages, EAD PCR detected Pp at every weekly time point; SBS failed to detect Pp in all cases. The minimal prevalence of Pp-infected mice required to obtain a reliable positive result by EAD PCR testing was determined to be 1 in 63 cages. Reliable detection of Pp was achieved after only 1 wk of exposure. Analysis of EAD samples by real-time PCR assay provides a sensitive, simple, and reliable approach for Pp identification in laboratory mice.

  12. Exhaust Air Dust Monitoring is Superior to Soiled Bedding Sentinels for the Detection of Pasteurella pneumotropica in Individually Ventilated Cage Systems

    PubMed Central

    Miller, Manuel; Ritter, Bärbel; Zorn, Julia; Brielmeier, Markus

    2016-01-01

    Reliable detection of unwanted organisms is essential for meaningful health monitoring in experimental animal facilities. Currently, most rodents are housed in IVC systems, which prevent the aerogenic transmission of pathogens between cages. Typically soiled-bedding sentinels (SBS) exposed to soiled bedding collected from a population of animals within an IVC rack are tested as representatives, but infectious agents often go undetected due to inefficient transmission. Pasteurellaceae are among the most prevalent bacterial pathogens isolated from experimental mice, and the failure of SBS to detect these bacteria is well established. In this study, we investigated whether analysis of exhaust air dust (EAD) samples by using a sensitive and specific real-time PCR assay is superior to conventional SBS monitoring for the detection of Pasteurella pneumotropica (Pp) infections. In a rack with a known prevalence of Pp-positive mice, weekly EAD sampling was compared with the classic SBS method over 3 mo. In 6 rounds of testing, with a prevalence of 5 infected mice in each of 7 cages in a rack of 63 cages, EAD PCR detected Pp at every weekly time point; SBS failed to detect Pp in all cases. The minimal prevalence of Pp-infected mice required to obtain a reliable positive result by EAD PCR testing was determined to be 1 in 63 cages. Reliable detection of Pp was achieved after only 1 wk of exposure. Analysis of EAD samples by real-time PCR assay provides a sensitive, simple, and reliable approach for Pp identification in laboratory mice. PMID:27931316

  13. Antennal responses of an oligolectic bee and its cleptoparasite to plant volatiles.

    PubMed

    Dötterl, Stefan

    2008-05-01

    Cleptoparasitic or cuckoo bees lay their eggs in nests of other bees, and the parasitic larvae feed the food that had been provided for the host larvae. Nothing is known about the specific signals used by the cuckoo bees for host nest finding, but previous studies have shown that olfactory cues originating from the host bee alone, or the host bee and the larval provision are essential. Here, I compared by using gas chromatography coupled to electroantennographic detection (GC-EAD) the antennal responses of the oligolectic oil-bee Macropis fulvipes and their cleptoparasite, Epeoloides coecutiens, to dynamic headspace scent samples of Lysimachia punctata, a pollen and oil host of Macropis. Both bee species respond to some scent compounds emitted by L. punctata, and two compounds, which were also found in scent samples collected from a Macropis nest entrance, elicited clear signals in the antennae of both species. These compounds may not only play a role for host plant detection by Macropis, but also for host nest detection by Epeoloides. I hypothesise that oligolectic bees and their cleptoparasites use the same compounds for host plant and host nest detection, respectively.

  14. Review of Peak Detection Algorithms in Liquid-Chromatography-Mass Spectrometry

    PubMed Central

    Zhang, Jianqiu; Gonzalez, Elias; Hestilow, Travis; Haskins, William; Huang, Yufei

    2009-01-01

    In this review, we will discuss peak detection in Liquid-Chromatography-Mass Spectrometry (LC/MS) from a signal processing perspective. A brief introduction to LC/MS is followed by a description of the major processing steps in LC/MS. Specifically, the problem of peak detection is formulated and various peak detection algorithms are described and compared. PMID:20190954

  15. Simultaneous detection and quantification of select nitromusks, antimicrobial agent, and antihistamine in fish of grocery stores by gas chromatography-mass spectrometry.

    PubMed

    Foltz, James; Abdul Mottaleb, M; Meziani, Mohammed J; Rafiq Islam, M

    2014-07-01

    Continually detected biologically persistent nitromusks; galaxolide (HHCB), tonalide (AHTN) and musk ketone (MK), antimicrobial triclosan (TCS), and antihistamine diphenhydramine (DPH) were examined for the first time in edible fillets originating from eight fish species grown in salt- and fresh-water. The sampled fish collected from local grocery stores were homogenized, extracted, pre-concentrated and analyzed by gas chromatography-mass spectrometry (GC-MS) using selected ion monitoring (SIM). The presence of the target compounds in fish extracts was confirmed based on similar mass spectral features and retention behavior with standards. Internal standard based calibration plots were used for quantification. The HHCB, AHTN, TCS and DPH were consistently observed with concentration of 0.163-0.892, 0.068-0.904, 0.189-1.182, and 0.942-7.472 ng g(-1), respectively. These values are at least 1-3 orders of magnitude lower than those obtained in environmental fish specimens. The MK was not detected in any fish. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  17. Gas Chromatography-Infrared (GC-IR) Applications In Pesticide Chemistry

    NASA Astrophysics Data System (ADS)

    Kalasinsky, Kathryn S.

    1981-10-01

    After pesticides in bait formulation have been applied in the field, it is important that the fate of that amount of toxicant which has not been consumed by the pest is known. Many of these substances are not compatible with the environment and it is also important that their biodegradation be understood and controlled to a certain extent. In efforts to monitor and direct these reactions GC-IR has been found to be an invaluable tool.

  18. Study of the rice straw biodegradation in mixed culture of Trichoderma viride and Aspergillus niger by GC-MS and FTIR.

    PubMed

    Chen, Yaoning; Huang, Jingxia; Li, Yuanping; Zeng, Guangming; Zhang, Jiachao; Huang, Aizhi; Zhang, Jie; Ma, Shuang; Tan, Xuebin; Xu, Wei; Zhou, Wei

    2015-07-01

    This study was conducted to investigate the biodegradation ability of the mixed culture of Trichoderma viride and Aspergillus niger through the study of the organic matter extracted from rice straw and the lignocellulose structure by using gas chromatography-mass spectrometer (GC-MS) and Fourier transform infrared spectroscopy (FTIR). The results of the GC-MS showed that the mixed culture possessed shorter alkane (heptane) at the end of the incubation and more kinds of organic matter (except the alkanes, 29 kinds of organic matter were detected) than the pure cultures. It could be deduced that the organic matter could indicate the degradation degree of the lignocellulose to some extent. Moreover, pinene was detected in the mixed culture on days 5 and 10, which might represent the antagonistic relationship between T. viride and A. niger. The analysis of FTIR spectrums which indirectly verified the GC-MS results showed that the mixed culture possessed a better degradation of rice straw compared with the pure culture. Therefore, the methods used in this research could be considered as effective ones to investigate the lignocellulose degradation mechanism in mixed culture.

  19. A NEW METHOD OF PEAK DETECTION FOR ANALYSIS OF COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY MASS SPECTROMETRY DATA.

    PubMed

    Kim, Seongho; Ouyang, Ming; Jeong, Jaesik; Shen, Changyu; Zhang, Xiang

    2014-06-01

    We develop a novel peak detection algorithm for the analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOF MS) data using normal-exponential-Bernoulli (NEB) and mixture probability models. The algorithm first performs baseline correction and denoising simultaneously using the NEB model, which also defines peak regions. Peaks are then picked using a mixture of probability distribution to deal with the co-eluting peaks. Peak merging is further carried out based on the mass spectral similarities among the peaks within the same peak group. The algorithm is evaluated using experimental data to study the effect of different cut-offs of the conditional Bayes factors and the effect of different mixture models including Poisson, truncated Gaussian, Gaussian, Gamma, and exponentially modified Gaussian (EMG) distributions, and the optimal version is introduced using a trial-and-error approach. We then compare the new algorithm with two existing algorithms in terms of compound identification. Data analysis shows that the developed algorithm can detect the peaks with lower false discovery rates than the existing algorithms, and a less complicated peak picking model is a promising alternative to the more complicated and widely used EMG mixture models.

  20. A NEW METHOD OF PEAK DETECTION FOR ANALYSIS OF COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY MASS SPECTROMETRY DATA*

    PubMed Central

    Kim, Seongho; Ouyang, Ming; Jeong, Jaesik; Shen, Changyu; Zhang, Xiang

    2014-01-01

    We develop a novel peak detection algorithm for the analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOF MS) data using normal-exponential-Bernoulli (NEB) and mixture probability models. The algorithm first performs baseline correction and denoising simultaneously using the NEB model, which also defines peak regions. Peaks are then picked using a mixture of probability distribution to deal with the co-eluting peaks. Peak merging is further carried out based on the mass spectral similarities among the peaks within the same peak group. The algorithm is evaluated using experimental data to study the effect of different cut-offs of the conditional Bayes factors and the effect of different mixture models including Poisson, truncated Gaussian, Gaussian, Gamma, and exponentially modified Gaussian (EMG) distributions, and the optimal version is introduced using a trial-and-error approach. We then compare the new algorithm with two existing algorithms in terms of compound identification. Data analysis shows that the developed algorithm can detect the peaks with lower false discovery rates than the existing algorithms, and a less complicated peak picking model is a promising alternative to the more complicated and widely used EMG mixture models. PMID:25264474

  1. Detection and identification of plasma progesterone metabolites in the female Florida manatee (Trichechus manatus latirostris) using GC/MS/MS.

    PubMed

    Tripp, K M; Dubois, M; Delahaut, P; Verstegen, J P

    2009-08-01

    Florida manatees (Trichechus manatus latirostris) have relatively low peripheral concentrations of progesterone (P4). The objective of this study was to determine if these relatively low P4 concentrations are associated with a high ratio of progestin metabolites and to document metabolite concentrations from individual blood samples obtained from manatees during diestrus or pregnancy. Metabolites known to exist in elephants-terrestrial manatee relatives-were targeted. These included 5alpha-reduced progestins (5alpha-pregnane-3,20-dione [5alpha-DHP] and 3alpha-hydroxy-5alpha-pregnan-20-one [5alpha-P3-OH]) and 17alpha-hydroxyprogesterone (17alpha-OHP), which occurs in Asian elephants. An additional, inactive metabolite, 20alpha-hydroxyprogesterone (20alpha-OHP), indicative of P4 overproduction, was also targeted. Progesterone itself was the predominant progestin detected in pregnant and nonpregnant manatee plasma (n = 10) using gas chromatography-mass spectrometry with tandem quadrupole detectors (GC/MS/MS). Progesterone concentrations in pregnant females varied from early (moderate to high) through mid and late (low) pregnancy. Progesterone concentrations ranged from low to high in nonpregnant, nonlactating females. The most commonly detected metabolite was 5alpha-P3-OH (n = 7), which occurred in pregnant (lower limit of detection [LLOD] to high) and nonpregnant (trace to high) females. The 5alpha-DHP metabolite was also detected in pregnant (LLOD to moderate) and nonpregnant (low) females. The 17alpha-OHP metabolite was not detected in any tested female. The 20alpha-OHP metabolite was detected in one nonpregnant, nonlactating, captive female (LLOD). Metabolites were most prevalent during early pregnancy, concurrent with maximum P4 concentrations. Based on their concentrations in peripheral circulation, we inferred that these metabolites may have, opposite to elephants, a limited physiologic role during luteal, pregnant, and nonpregnant phases in the manatee.

  2. Power of Orbitrap-based LC-high resolution-MS/MS for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MSn or GC-MS procedures.

    PubMed

    Michely, Julian A; Meyer, Markus R; Maurer, Hans H

    2018-01-01

    Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Determination of patulin in fruit juices using HPLC-DAD and GC-MSD techniques.

    PubMed

    Moukas, Athanasios; Panagiotopoulou, Vasiliki; Markaki, Panagiota

    2008-08-15

    A high performance liquid chromatography with a diode-array detector (HPLC-DAD) and a gas chromatography with a mass spectrometer (GC-MSD) are described for the determination of patulin (PAT) in apple juice. The limits of detection (DL) and quantification (QL) for the HPLC-DAD and GC-MSD method were found to be (DL=0.23μgkg(-1) QL=1.2μgkg(-1)) and (DL=5.8μgkg(-1) and QL=13.8μgkg(-1)), respectively. The recovery factors for HPLC-DAD and GC-MSD were found to be 99.5% (RSD%=0.73) and 41% (RSD%=10.03), respectively. The HPLC-DAD method was used to determine the occurrence of PAT in 90 samples of fruit juices. Results revealed the presence of PAT in 100% of the samples examined. The mean values of PAT in concentrated fruit juices and in the commercial fruit juices collected from the Greek market were found to be 10.54μg PAT kg(-1) and 5.57μg PAT kg(-1) juice, respectively. The most contaminated samples were four concentrated juices ranging from 18.10μg PAT kg(-1) to 36.8μg PAT kg(-1) juice. The daily exposure to patulin for the consumers of all ages in Greece, is ranging from 0.008μg PAT kg(-1) bw to 0.1μg PAT kg(-1) bw if the daily intake of fruit juices is from 0.1 to 0.5kg. With the exception to the most contaminated sample, the daily exposure due to the samples examined, is below the provisional maximum tolerable daily intake for PAT (0.4μg PAT kg(-1) bw). Copyright © 2008 Elsevier Ltd. All rights reserved.

  4. Results of the First Mars Organic Molecule Analyzer (MOMA) GC-MS Coupling

    NASA Astrophysics Data System (ADS)

    Buch, Arnaud; Pinnick, Veronica; Szopa, Cyril; Danell, Ryan; Grand, Noel; Van Amerom, Friso; Glavin, Daniel; Freissinet, Caroline; Humeau, Olivier; Coll, Patrice; Arevalo, Ricardo; Stalport, Fabien; Brinckerhoff, William; Steininger, Harald; Goesmann, Fred; Mahaffy, Paul; Raulin, Francois

    2014-11-01

    The Mars Organic Molecule Analyzer (MOMA) aboard the ExoMars rover will be a key analytical tool in providing chemical (molecular) information from the solid samples collected by the rover, with a particular focus on the char-acterization of the organic content. The core of the MOMA instrument is a gas chromatograph coupled with a mass spectrometer (GC-MS) which provides the unique capability to characterize a broad range of compounds, including both of volatile and non-volatile species. Samples will be crushed and deposited into sample cups seated in a rotating carousel. Soil samples will be analyzed either by UV laser desorption / ionization (LDI) or pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS).The French GC brassboard was coupled to the US ion trap mass spectrometer brassboard in a flight-like con-figuration for several coupling campains. The MOMA GC setup is based on the SAM heritage design with a He reservoir and 4 separate analytical modules including traps, columns and Thermal Conductivity Detectors. Solid samples are sealed and heated in this setup using a manual tapping station, designed and built at MPS in Germany, for GC-MS analysis. The gaseous species eluting from the GC are then ionized by an electron impact ionization source in the MS chamber and analyzed by the linear ion trap mass spectrometer. Volatile and non-volatile compounds were injected in the MOMA instrumental suite. Both of these compounds classes were detected by the TCD and by the MS. MS signal (total ion current) and single mass spectra by comparison with the NIST library, gave us an unambiguous confirmation of these identifications. The mass spectra arise from an average of 10 mass spectra averaged around a given time point in the total ion chromatogram.Based on commercial instrument, the MOMA requirement for sensitivity in the GC-MS mode for organic molecules is 1 pmol. In this test, sensitivity was determined for the GC TCD and MS response to a dilution

  5. Identification of natural indigo in historical textiles by GC-MS.

    PubMed

    Degani, Laura; Riedo, Chiara; Chiantore, Oscar

    2015-02-01

    The possibility of successfully applying a common GC-MS procedure for identification in one step of all types of dyes from plants of unknown origin and from historical objects is particularly attractive due to the high separation efficiency of the capillary columns, the MS detection sensitivity and the reproducibility of results. In this work, GC-MS analysis, previously and successfully used for the characterization of anthraquinones, flavonoids and tannins from plant extracts and historical samples, has been tested on indigoid dyestuffs. An analytical procedure based on the silylating agent N,O-bis-(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane (TMCS) was applied to pure molecules of indigotin and indirubin and to plant extracts of Indigofera tinctoria L. and Isatis tinctoria L. Preliminary tests have been done to establish the chromatographic conditions and the derivatization amounts most suitable for the simultaneous detection of indigoid molecules and of the other natural compounds, such as fatty acids, carboxylic acids and sugars, contained within the plant extracts. In order to assess the capacity and the sensitivity of the analytical procedure in typical archaeometric applications, wool samples dyed in the laboratory with indigo were analysed by mimicking the sample amounts typically available with historical objects. The electron ionization (EI) spectra of the main silylated derivatives of indigoid molecules obtained in this way constitute the necessary data set for the characterization of natural extracts and historical works of art. Subsequently, the procedure has been applied to historical samples for the detection of indigo and of other dyestuffs eventually contained in samples. Additional information, useful for restoration and preservation of works of art, could be also obtained on the nature of stains and smudges present on the sampled textile material. The GC-MS method turns out to be an efficient and fast analytical tool

  6. A gas chromatography-mass spectrometry (GC-MS) method for the detection and quantitation of monofluoroacetate in plants toxic to livestock

    USDA-ARS?s Scientific Manuscript database

    Monofluoroacetate (MFA) is a potent toxin that occurs in over 50 plant species in Africa, Australia, and South America and is responsible for significant livestock deaths in these regions. A gas chromatography–mass spectrometry (GC-MS) method for the analysis of MFA in plants based on the derivatiza...

  7. A gas chromatography-mass spectrometry (GC-MS) method for the detection and quantitation of monofluoroacetate in plants toxic to livestock

    USDA-ARS?s Scientific Manuscript database

    Monofluoroacetate (MFA) is a potent toxin that occurs in over 50 plant species in Africa, Australia, and South America and is responsible for significant livestock deaths in these regions. A gas chromatography–mass spectrometry (GC-MS) method for the analysis of MFA in plants based on the derivatiz...

  8. Gc protein (vitamin D-binding protein): Gc genotyping and GcMAF precursor activity.

    PubMed

    Nagasawa, Hideko; Uto, Yoshihiro; Sasaki, Hideyuki; Okamura, Natsuko; Murakami, Aya; Kubo, Shinichi; Kirk, Kenneth L; Hori, Hitoshi

    2005-01-01

    The Gc protein (human group-specific component (Gc), a vitamin D-binding protein or Gc globulin), has important physiological functions that include involvement in vitamin D transport and storage, scavenging of extracellular G-actin, enhancement of the chemotactic activity of C5a for neutrophils in inflammation and macrophage activation (mediated by a GalNAc-modified Gc protein (GcMAF)). In this review, the structure and function of the Gc protein is focused on especially with regard to Gc genotyping and GcMAF precursor activity. A discussion of the research strategy "GcMAF as a target for drug discovery" is included, based on our own research.

  9. Determination of urea kinetics by isotope dilution with [13C]urea and gas chromatography-isotope ratio mass spectrometry (GC-IRMS) analysis.

    PubMed

    Kloppenburg, W D; Wolthers, B G; Stellaard, F; Elzinga, H; Tepper, T; de Jong, P E; Huisman, R M

    1997-07-01

    1. Stable urea isotopes can be used to study urea kinetics in humans. The use of stable urea isotopes for studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material. We devised a urea dilution for measurement of the distribution volume, production rate and clearance of urea in healthy subjects and renal failure patients using the inexpensive single labelled [13C]urea isotope with subsequent analysis by headspace chromatography-isotope ratio MS (GC-IRMS) of the [13C]urea enrichment. 2. The method involves measurement of the molar percentage excess of [13C]urea in plasma samples taken over a 4 h period after an intravenous bolus injection of [13C]urea. During the sample processing procedure, the plasma samples together with calibration samples containing a known molar percentage excess of [13C]urea are acidified with phosphoric acid to remove endogenous CO2, and are subsequently incubated with urease to convert the urea present in the plasma samples into CO2. The 13C enrichment of the generated CO2 is analysed by means of GC-IRMS. This method allows measurement of the molar percentage excess of [13C]urea to an accuracy of 0.02%. 3. Reproducibility studies showed that the sample processing procedure [within-run coefficient of variation (CV) < 2.8% and between-run CV < 8.8%] and the GC-IRMS analysis (within-day CV < 1.3% and between-day CV < 1.3%) could be repeated with good reproducibility. 4. In clinical urea kinetic studies in a healthy subject and in a renal failure patient without residual renal function, reproducible values of the distribution volume, production rate and clearance of urea were determined using minimal amounts of [13C]urea (25-50 mg). 5. Because only low [13C]urea enrichments are needed in this urea dilution method using GC-IRMS analysis, the costs of urea kinetic studies are reduced considerably, especially in patients with renal failure.

  10. GC/MS analysis of high-performance liquid chromatography fractions from Sophora flavescens and Torilis japonica extracts and their in vitro anti-neosporal effects on Neospora caninum.

    PubMed

    Seo, Hun-Su; Kim, Kyoung Hee; Kim, Dae-Yong; Park, Bong-Kyun; Shin, Nam-Shik; Kim, Jae-Hoon; Youn, Heejeong

    2013-01-01

    We analyzed alcoholic extracts of herbs possessing anti-neosporal activity against Neospora (N.) caninum. To identify the chemical components of Sophora (S.) flavescens and Torilis (T.) japonica associated with anti-neosporal activity, specific fractions were isolated by high-performance liquid chromatography (HPLC). In vitro activity of the fractions against N. caninum was then assessed. Gas chromatography/ mass spectrometry (GC/MS) was used to identify and quantify specific anti-neosporal molecules in the herbal extracts. Almost all HPLC fractions of S. flavescens and T. japonica had higher levels of anti-neosporal activity compared to the not treated control. Active constituents of the extracts were sophoridane, furosardonin A, and tetraisopropylidene-cyclobutane in S. flavescens; 5,17-β-dihydroxy-de-A-estra-5,7,9,14-tetraene, furanodiene, and 9,12-octadecadienoic acid (Z,Z)-(CAS,1) in T. japonica.

  11. GC/MS analysis of high-performance liquid chromatography fractions from Sophora flavescens and Torilis japonica extracts and their in vitro anti-neosporal effects on Neospora caninum

    PubMed Central

    Seo, Hun-Su; Kim, Kyoung Hee; Kim, Dae-Yong; Park, Bong-Kyun; Shin, Nam-Shik; Kim, Jae-Hoon

    2013-01-01

    We analyzed alcoholic extracts of herbs possessing anti-neosporal activity against Neospora (N.) caninum. To identify the chemical components of Sophora (S.) flavescens and Torilis (T.) japonica associated with anti-neosporal activity, specific fractions were isolated by high-performance liquid chromatography (HPLC). In vitro activity of the fractions against N. caninum was then assessed. Gas chromatography/mass spectrometry (GC/MS) was used to identify and quantify specific anti-neosporal molecules in the herbal extracts. Almost all HPLC fractions of S. flavescens and T. japonica had higher levels of anti-neosporal activity compared to the not treated control. Active constituents of the extracts were sophoridane, furosardonin A, and tetraisopropylidene-cyclobutane in S. flavescens; 5,17-β-dihydroxy-de-A-estra-5,7,9,14-tetraene, furanodiene, and 9,12-octadecadienoic acid (Z,Z)-(CAS,1) in T. japonica. PMID:23820198

  12. Acid monomer analysis in waterborne polymer systems by targeted labeling of carboxylic acid functionality, followed by pyrolysis - gas chromatography.

    PubMed

    Brooijmans, T; Okhuijsen, R; Oerlemans, I; Schoenmakers, P J; Peters, R

    2018-05-14

    Pyrolysis - gas chromatography - (PyGC) is a common method to analyse the composition of natural and synthetic resins. The analysis of acid functionality in, for example, waterborne polyacrylates and polyurethanes polymers has proven to be difficult due to solubility issues, inter- and intramolecular interaction effects, lack of detectability in chromatographic analysis, and lack of thermal stability. Conventional analytical techniques, such as PyGC, cannot be used for the direct detection and identification of acidic monomers, due to thermal rearrangements that take place during pyrolysis. To circumvent this, the carboxylic acid groups are protected prior to thermal treatment by reaction with 2-bromoacetophenone. Reaction conditions are investigated and optimised wrt. conversion measurements. The aproach is applied to waterborne polyacryalates and the results are discussed. This approach enables identification and (semi)quantitative analysis of different acid functionalities in waterborne polymers by PyGC. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. A One-Pot/Single-Analysis Approach to Substrate Scope Investigations Using Comprehensive Two-Dimensional Gas Chromatography (GC×GC).

    PubMed

    O'Neil, Gregory W; Nelson, Robert K; Wright, Alicia M; Reddy, Christopher M

    2016-05-06

    A representative substrate scope investigation for an enantioselective catalytic ketone-reduction has been performed as a single reaction on a mixture containing equimolar amounts of nine (9) prototypical compounds. The resulting analyte pool containing 18 potential products from nine different reactions could all be completely resolved in a single chromatographic injection using comprehensive two-dimensional gas chromatography (GC×GC) with time-of-flight mass spectrometry, allowing for simultaneous determination of percent conversion and enantiomeric excess for each substrate. The results obtained for an enantioselective iron-catalyzed asymmetric transfer hydrogenation using this one-pot/single-analysis approach were similar to those reported for the individualized reactions, demonstrating the utility of this strategy for streamlining substrate scope investigations. Moreover, for this particular catalyst, activity and selectivity were not greatly affected by the presence of other ketones or enantioenriched reduced products. This approach allows for faster and greener analyses that are central to new reaction development, as well as an opportunity to gain further insights into other established transformations.

  14. Evaporation Rates of Chemical Warfare Agents Using 5-CM Wind Tunnels I. CASARM Sulfur Mustard (HD) from Glass

    DTIC Science & Technology

    2008-10-01

    Blank CONTENTS 1. INTRODUCTION 9 2. EXPERIMENTAL PROCEDURES 9 2.1 Wind Tunnel 9 2.2 Agent 10 2.3 Gas Chromatography /Mass Spectrometry Detection 10...protective equipment. 2.3 Gas Chromatography /Mass Spectrometry Detection (GC/MSD) The GC/MSD analysis of the thermal desorption tubes was performed on a...coupled to thermal desorption tubes that were analyzed using gas chromatography /mass spectrometry detection (GC/MSD). Differences between the tunnels

  15. Identification of odors from overripe mango that attract vinegar flies, Drosophila melanogaster.

    PubMed

    Zhu, Junwei; Park, Kye-Chung; Baker, Thomas C

    2003-04-01

    Bioassays with a variety of overripe fruits, including mango, plum, pear, and grape, and their extracts showed that odors from overripe mango were most attractive to adult vinegar flies, Drosophila melanogaster. Combined gas chromatography-electroantennographic detection (GC-EAD) analyses of solid-phase microextraction (SPME) and Tenax extracts of overripe mango odors showed that several volatile compounds, including ethanol, acetic acid, amyl acetate, 2-phenylethanol, and phenylethyl acetate elicited significant EAG responses from antennae of female flies. Most of the volatile compounds in the extracts were identified by mass spectral and retention index comparisons with synthetic standards. In cage bioassays, lures with a blend of ethanol, acetic acid, and 2-phenylethanol in a ratio of 1:22:5 attracted six times more flies than any single EAG-active compound. This blend also attracted four times more flies than traps baited with overripe mango or unripe mango. However, in field trials, the blend was not as attractive as suggested by the laboratory bioassay.

  16. Structure of the mouse glucocorticoid receptor: rapid analysis by size-exclusion high-performance liquid chromatography.

    PubMed

    LaPointe, M C; Chang, C H; Vedeckis, W V

    1986-04-22

    Gel-exclusion high-performance liquid chromatography (HPLC) has been used to separate the untransformed from the transformed glucocorticoid receptor (GC-R) extracted from mouse AtT-20 cells. With 200 mM potassium phosphate as the eluent, an efficient separation of the forms of the GC-R is attained in 15-20 min. The untransformed cytosolic GC-R elutes from the column with a Stokes radius (Rs) of 8.2-8.6 nm, as do the molybdate-stabilized GC-R, the purified untransformed GC-R, and the cross-linked cytosolic GC-R. GC-R transformed in vitro by either ammonium sulfate precipitation, KCl treatment, or G-25 chromatography elutes with an Rs of 5.7-6 nm. Also, GC-R extracted from the nucleus with either 0.3 M KCl or 2 mM sodium tungstate, or purified by two cycles of DNA-cellulose chromatography, has an Rs of 5.5-6.3 nm. The data are identical either in the presence or in the absence of 20 mM Na2MoO4, suggesting that molybdate is not causing aggregation to produce a larger Rs value than that of the native receptor. Vertical tube rotor sucrose gradient ultracentrifugation of cytosol produces three forms of the GC-R: 9.1 S, 5.2 S, and 3.8 S. Sequential analysis of the GC-R forms by HPLC and vertical tube rotor ultracentrifugation and vice versa allows for the hydrodynamic determination of molecular weight within a very short time period (2-3 h total).(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Solid-phase extraction-gas chromatography and solid-phase extraction-gas chromatography-mass spectrometry determination of corrosion inhibiting long-chain primary alkyl amines in chemical treatment of boiler water in water-steam systems of power plants.

    PubMed

    Kusch, Peter; Knupp, Gerd; Hergarten, Marcus; Kozupa, Marian; Majchrzak, Maria

    2006-04-28

    Gas chromatography with simultaneous flame-ionization detection (FID) and a nitrogen-phosphorus detection (NPD) as well as gas chromatography-mass spectrometry (GC/MS) has been used to characterize long-chain primary alkyl amines after derivatization with trifluoroacetic anhydride (TFAA). Electron impact ionization- (EI) and negative chemical ionization (NCI) mass spectra of trifluoroacetylated derivatives of the identified tert-octadecylamines are presented for the first time. The corrosion inhibiting alkyl amines were applied in a water-steam circuit of energy systems in the power industry. Solid-phase extraction (SPE) with octadecyl bonded silica (C18) sorbents followed by gas chromatography were used for quantification of the investigated tert-octadecylamines in boiler water, superheated steam and condensate samples from the power plant. The estimated values were: 89 microg l(-1)(n = 5, RSD = 7.8%), 45 microg l(-1) (n = 5, RSD = 5.4%) and 37 microg l(-1)(n = 5, RSD = 2.3%), respectively.

  18. Achieving high peak capacity production for gas chromatography and comprehensive two-dimensional gas chromatography by minimizing off-column peak broadening.

    PubMed

    Wilson, Ryan B; Siegler, W Christopher; Hoggard, Jamin C; Fitz, Brian D; Nadeau, Jeremy S; Synovec, Robert E

    2011-05-27

    By taking into consideration band broadening theory and using those results to select experimental conditions, and also by reducing the injection pulse width, peak capacity production (i.e., peak capacity per separation time) is substantially improved for one dimensional (1D-GC) and comprehensive two dimensional (GC×GC) gas chromatography. A theoretical framework for determining the optimal linear gas velocity (the linear gas velocity producing the minimum H), from experimental parameters provides an in-depth understanding of the potential for GC separations in the absence of extra-column band broadening. The extra-column band broadening is referred to herein as off-column band broadening since it is additional band broadening not due to the on-column separation processes. The theory provides the basis to experimentally evaluate and improve temperature programmed 1D-GC separations, but in order to do so with a commercial 1D-GC instrument platform, off-column band broadening from injection and detection needed to be significantly reduced. Specifically for injection, a resistively heated transfer line is coupled to a high-speed diaphragm valve to provide a suitable injection pulse width (referred to herein as modified injection). Additionally, flame ionization detection (FID) was modified to provide a data collection rate of 5kHz. The use of long, relatively narrow open tubular capillary columns and a 40°C/min programming rate were explored for 1D-GC, specifically a 40m, 180μm i.d. capillary column operated at or above the optimal average linear gas velocity. Injection using standard auto-injection with a 1:400 split resulted in an average peak width of ∼1.5s, hence a peak capacity production of 40peaks/min. In contrast, use of modified injection produced ∼500ms peak widths for 1D-GC, i.e., a peak capacity production of 120peaks/min (a 3-fold improvement over standard auto-injection). Implementation of modified injection resulted in retention time, peak width

  19. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  20. Performance evaluation of a versatile multidimensional chromatographic preparative system based on three-dimensional gas chromatography and liquid chromatography-two-dimensional gas chromatography for the collection of volatile constituents.

    PubMed

    Pantò, Sebastiano; Sciarrone, Danilo; Maimone, Mariarosa; Ragonese, Carla; Giofrè, Salvatore; Donato, Paola; Farnetti, Sara; Mondello, Luigi

    2015-10-23

    The present research deals with the multi-collection of the most important sesquiterpene alcohols belonging to sandalwood essential oil, as reported by the international regulations: (Z)-α-santalol, (Z)-α-trans bergamotol, (Z)-β-santalol, epi-(Z)-β-santalol, α-bisabolol, (Z)-lanceol, and (Z)-nuciferol. A versatile multidimensional preparative system, based on the hyphenation of liquid and gas chromatography techniques, was operated in the LC-GC-GC-prep or GC-GC-GC-prep configuration, depending on the concentration to be collected from the sample, without any hardware or software modification. The system was equipped with a silica LC column in combination with polyethylene glycol-poly(5% diphenyl/95% dimethylsiloxane)-medium polarity ionic liquid or β-cyclodextrin based GC stationary phases. The GC-GC-GC-prep configuration was exploited for the collection of four components, by using a conventional split/splitless injector, while the LC-GC-GC-prep approach was applied for three low abundant components (<5%), in order to increase the quantity collected within a single run, by the LC injection of a high sample amount. All target compounds, whose determination is hampered by the unavailability of commercial standards, were collected at milligram levels and with a high degree of purity (>87%). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Automated GC-MS analysis of free amino acids in biological fluids.

    PubMed

    Kaspar, Hannelore; Dettmer, Katja; Gronwald, Wolfram; Oefner, Peter J

    2008-07-15

    A gas chromatography-mass spectrometry (GC-MS) method was developed for the quantitative analysis of free amino acids as their propyl chloroformate derivatives in biological fluids. Derivatization with propyl chloroformate is carried out directly in the biological samples without prior protein precipitation or solid-phase extraction of the amino acids, thereby allowing automation of the entire procedure, including addition of reagents, extraction and injection into the GC-MS. The total analysis time was 30 min and 30 amino acids could be reliably quantified using 19 stable isotope-labeled amino acids as internal standards. Limits of detection (LOD) and lower limits of quantification (LLOQ) were in the range of 0.03-12 microM and 0.3-30 microM, respectively. The method was validated using a certified amino acid standard and reference plasma, and its applicability to different biological fluids was shown. Intra-day precision for the analysis of human urine, blood plasma, and cell culture medium was 2.0-8.8%, 0.9-8.3%, and 2.0-14.3%, respectively, while the inter-day precision for human urine was 1.5-14.1%.

  2. Speciation analysis of organotin compounds in human urine by headspace solid-phase micro-extraction and gas chromatography with pulsed flame photometric detection.

    PubMed

    Valenzuela, Aníbal; Lespes, Gaëtane; Quiroz, Waldo; Aguilar, Luis F; Bravo, Manuel A

    2014-07-01

    A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that varymore » as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our

  4. Simultaneous determination of chlorinated organic compounds from environmental samples using gas chromatography coupled with a micro electron capture detector and micro-plasma atomic emission detector

    NASA Astrophysics Data System (ADS)

    Quan, Xie; Chen, Shuo; Platzer, Bernhard; Chen, Jingwen; Gfrerer, Marion

    2002-01-01

    Water and sediment samples were screened simultaneously for the presence of polychlorinated organic compounds using gas chromatography (GC) coupled with an micro electron capture detector (μ-ECD) and a newly developed helium plasma based on a micro-atomic emission detector (μ-AED). The GC column effluent was split 15:85 between two detectors. In this way, two chromatograms, one obtained by μ-ECD and another by μ-AED, were recorded simultaneously. α-, β-hexachlorocyclohexane and p, p'-DDE were detected. RSDs of the monitoring results from the two detection methods were <20% for the three compounds. A detection limit of 8.5 pg and at least 3 orders of magnitude of linear range for μ-AED was observed.

  5. PyMS: a Python toolkit for processing of gas chromatography-mass spectrometry (GC-MS) data. Application and comparative study of selected tools

    PubMed Central

    2012-01-01

    Background Gas chromatography–mass spectrometry (GC-MS) is a technique frequently used in targeted and non-targeted measurements of metabolites. Most existing software tools for processing of raw instrument GC-MS data tightly integrate data processing methods with graphical user interface facilitating interactive data processing. While interactive processing remains critically important in GC-MS applications, high-throughput studies increasingly dictate the need for command line tools, suitable for scripting of high-throughput, customized processing pipelines. Results PyMS comprises a library of functions for processing of instrument GC-MS data developed in Python. PyMS currently provides a complete set of GC-MS processing functions, including reading of standard data formats (ANDI- MS/NetCDF and JCAMP-DX), noise smoothing, baseline correction, peak detection, peak deconvolution, peak integration, and peak alignment by dynamic programming. A novel common ion single quantitation algorithm allows automated, accurate quantitation of GC-MS electron impact (EI) fragmentation spectra when a large number of experiments are being analyzed. PyMS implements parallel processing for by-row and by-column data processing tasks based on Message Passing Interface (MPI), allowing processing to scale on multiple CPUs in distributed computing environments. A set of specifically designed experiments was performed in-house and used to comparatively evaluate the performance of PyMS and three widely used software packages for GC-MS data processing (AMDIS, AnalyzerPro, and XCMS). Conclusions PyMS is a novel software package for the processing of raw GC-MS data, particularly suitable for scripting of customized processing pipelines and for data processing in batch mode. PyMS provides limited graphical capabilities and can be used both for routine data processing and interactive/exploratory data analysis. In real-life GC-MS data processing scenarios PyMS performs as well or better than

  6. Procedure for the determination of retinol and alpha-tocopherol in poultry tissues using capillary gas chromatography with solvent venting injection.

    PubMed

    Maraschiello, C; García Regueiro, J A

    1998-08-28

    A procedure designed for the determination of retinol (vitamin A) and alpha-tocopherol (vitamin E) in poultry tissues has been developed. The procedure involves lipid extraction, saponification, solid-phase clean-up and capillary gas chromatography (cGC). Retinol and alpha-tocopherol were determined separately by cGC-flame ionisation detection using a fused-silica open tubular capillary column, 30 m x 0.25 mm I.D. coated with 5% phenylmethylsilicone and with a film thickness of 0.25 micron. Solvent extraction followed by saponification were sufficient to provide a purified extract which was directly analyzed for retinol by cGC in the solvent venting mode. However, in order to accurately determine alpha-tocopherol by cGC, further purification of the extract by solid-phase extraction was necessary. A silica SPE column was used to remove interfering cholesterol from the extract. alpha-Tocopherol was analyzed in its derivatized form. Absolute and relative recoveries for both vitamins from spiked samples were evaluated. Absolute and relative recoveries ranging from 80 to 95% were obtained for both compounds. 5 alpha-Cholestane and alpha-tocopheryl acetate were used as internal standards. Poultry muscle meat and liver tissue were analyzed for their retinol and alpha-tocopherol content and the peaks detected by cGC were confirmed by cGC-mass spectrometry.

  7. Quantitative Determination of Caffeine in Beverages Using a Combined SPME-GC/MS Method

    NASA Astrophysics Data System (ADS)

    Pawliszyn, Janusz; Yang, Min J.; Orton, Maureen L.

    1997-09-01

    Solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of various caffeinated beverages. Unlike the current methods, this technique is solvent free and requires no pH adjustments. The simplicity of the SPME-GC/MS method lends itself to a good undergraduate laboratory practice. This publication describes the analytical conditions and presents the data for determination of caffeine in coffee, tea, and coke. Quantitation by isotopic dilution is also illustrated.

  8. Freeze drying for gas chromatography stationary phase deposition

    DOEpatents

    Sylwester, Alan P [Livermore, CA

    2007-01-02

    The present disclosure relates to methods for deposition of gas chromatography (GC) stationary phases into chromatography columns, for example gas chromatography columns. A chromatographic medium is dissolved or suspended in a solvent to form a composition. The composition may be inserted into a chromatographic column. Alternatively, portions of the chromatographic column may be exposed or filled with the composition. The composition is permitted to solidify, and at least a portion of the solvent is removed by vacuum sublimation.

  9. Determination of Porosity in Shale by Double Headspace Extraction GC Analysis.

    PubMed

    Zhang, Chun-Yun; Li, Teng-Fei; Chai, Xin-Sheng; Xiao, Xian-Ming; Barnes, Donald

    2015-11-03

    This paper reports on a novel method for the rapid determination of the shale porosity by double headspace extraction gas chromatography (DHE-GC). Ground core samples of shale were placed into headspace vials and DHE-GC measurements of released methane gas were performed at a given time interval. A linear correlation between shale porosity and the ratio of consecutive GC signals was established both theoretically and experimentally by comparing with the results from the standard helium pycnometry method. The results showed that (a) the porosity of ground core samples of shale can be measured within 30 min; (b) the new method is not significantly affected by particle size of the sample; (c) the uncertainties of measured porosities of nine shale samples by the present method range from 0.31 to 0.46 p.u.; and (d) the results obtained by the DHE-GC method are in a good agreement with those from the standard helium pycnometry method. In short, the new DHE-GC method is simple, rapid, and accurate, making it a valuable tool for shale gas-related research and applications.

  10. Determination of free amino compounds in betalainic fruits and vegetables by gas chromatography with flame ionization and mass spectrometric detection.

    PubMed

    Kugler, Florian; Graneis, Stephan; Schreiter, Pat P-Y; Stintzing, Florian C; Carle, Reinhold

    2006-06-14

    Amino acids and amines are the precursors of betalains. Therefore, the profiles of free amino compounds in juices obtained from cactus pears [Opuntia ficus-indica (L.) Mill. cv. Bianca, cv. Gialla, and cv. Rossa], pitaya fruits [Selenicereus megalanthus (K. Schumann ex Vaupel) Moran, Hylocereus polyrhizus (Weber) Britton & Rose, and Hylocereus undatus (Haworth) Britton & Rose], and in extracts from differently colored Swiss chard [Beta vulgaris L. ssp. cicla (L.) Alef. cv. Bright Lights] petioles and red and yellow beets (B. vulgaris L. ssp. vulgaris var. conditiva Alef. cv. Burpee's Golden) were investigated for the first time. Amino compounds were derivatized with propyl chloroformate. While gas chromatography (GC) with mass spectrometry was used for peak assignment, GC flame ionization detection was applied for quantification of individual compounds. Whereas proline was the major free amino compound of cactus pear and pitaya fruit juices, glutamine dominated in Swiss chard stems and beets, respectively. Interestingly, extremely high concentrations of dopamine were detected in Swiss chard stems and beets. Furthermore, the cleavage of betaxanthins caused by derivatization in alkaline reaction solutions is demonstrated for the first time. Amino acids and amines thus released might increase the actual free amino compound contents of the respective sample. To evaluate the contribution of betaxanthin cleavage to total amino acid and amine concentration, isolated betaxanthins were derivatized according to the "EZ:faast" method prior to quantification of the respective amino compounds released. On a molar basis, betaxanthin contribution to overall amino compound contents was always below 6.4%.

  11. GC-MS, LC-MS(n), LC-high resolution-MS(n), and NMR studies on the metabolism and toxicological detection of mesembrine and mesembrenone, the main alkaloids of the legal high "Kanna" isolated from Sceletium tortuosum.

    PubMed

    Meyer, Golo M J; Wink, Carina S D; Zapp, Josef; Maurer, Hans H

    2015-01-01

    Mesembrine and mesembrenone are the main alkaloids of Sceletium tortuosum, a plant species that was used for sedation and analgesia by the KhoiSan, previously known as Hottentots, a tribe in South Africa. After fermentation, the obtained preparation called "Kanna" or "Kougoed" was used by chewing, smoking, or sniffing. Today, Kanna gains popularity by drug users as legal high. For monitoring such consumption, metabolism studies are mandatory because the metabolites are mostly the analytical targets, especially in urine. Therefore, the metabolism of both alkaloids was investigated in rat urine and pooled human liver preparations after several sample work-up procedures. As both alkaloids were not commercially available, they were isolated from plant material by Soxhlet extraction, and their identity confirmed by NMR. The metabolites were identified using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography coupled to linear ion trap high resolution mass spectrometry (LC-HR-MS(n)). Both alkaloids were O- and N-demethylated, dihydrated, and/or hydroxylated at different positions. The phenolic metabolites were partly excreted as glucuronides and/or sulfates. Most of the phase I metabolites identified in rat urine could be detected also in the human liver preparations. After a common user's low dose application of mesembrine, mainly the O- and N demethyl-dihydro, hydroxy, and bis-demethyl-dihydro metabolites, and in case of mesembrenone only the N-demethyl and the N-demethyl-dihydro metabolite could be detected in rat urine using the authors' standard urine screening approaches (SUSA) by GC-MS or LC-MS(n). Thus, it should be possible to monitor a consumption of mesembrine and/or mesembrenone assuming similar pharmacokinetics in humans.

  12. Method for factor analysis of GC/MS data

    DOEpatents

    Van Benthem, Mark H; Kotula, Paul G; Keenan, Michael R

    2012-09-11

    The method of the present invention provides a fast, robust, and automated multivariate statistical analysis of gas chromatography/mass spectroscopy (GC/MS) data sets. The method can involve systematic elimination of undesired, saturated peak masses to yield data that follow a linear, additive model. The cleaned data can then be subjected to a combination of PCA and orthogonal factor rotation followed by refinement with MCR-ALS to yield highly interpretable results.

  13. Detection of anabolic and androgenic steroids and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry.

    PubMed

    Kwok, Karen Y; Choi, Timmy L S; Kwok, Wai Him; Wong, Jenny K Y; Wan, Terence S M

    2017-04-14

    Anabolic and androgenic steroids (AASs) are a class of prohibited substances banned in horseracing at all times. The common approach for controlling the misuse of AASs in equine sports is by detecting the presence of AASs and/or their metabolites in urine and blood samples using gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). This approach, however, often falls short as the duration of effect for many AASs are longer than their detection time in both urine and blood. As a result, there is a high risk that such AASs could escape detection in their official race-day samples although they may have been used during the long period of training. Hair analysis, on the other hand, can afford significantly longer detection windows. In addition, the identification of synthetic ester derivatives of AASs in hair, particularly for the endogenous ones, can provide unequivocal proof of their exogenous origin. This paper describes the development of a sensitive method (at sub to low parts-per-billion or ppb levels) for detecting 48 AASs and/or their esters in horse hair using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC-HRMS). Decontaminated horse hair was pulverised and subjected to in-situ liquid-liquid extraction in a mixture of hexane - ethyl acetate (7:3, v/v) and phosphate buffer (0.1M, pH 9.5), followed by additional clean-up using mixed-mode solid-phase extraction. The final extract was analysed using UHPLC-HRMS in the positive electrospray ionisation (ESI) mode with both full scan and parallel reaction monitoring (PRM). This method was validated for qualitative identification purposes. Validation data, including method specificity, method sensitivity, extraction recovery, method precision and matrix effect are presented. Method applicability was demonstrated by the successful detection and confirmation of testosterone propionate in a referee hair sample. To our knowledge, this was

  14. Introducing Students to Gas Chromatography-Mass Spectrometry Analysis and Determination of Kerosene Components in a Complex Mixture

    ERIC Educational Resources Information Center

    Pacot, Giselle Mae M.; Lee, Lyn May; Chin, Sung-Tong; Marriott, Philip J.

    2016-01-01

    Gas chromatography-mass spectrometry (GC-MS) and GC-tandem MS (GC-MS/MS) are useful in many separation and characterization procedures. GC-MS is now a common tool in industry and research, and increasingly, GC-MS/MS is applied to the measurement of trace components in complex mixtures. This report describes an upper-level undergraduate experiment…

  15. VOLATILE ORGANO-METALLOIDS IN BIO-SOLID MATERIALS: ANALYSIS BY VACUUM DISTILLATION-GC/MS

    EPA Science Inventory

    An analytical method based on vacuum distillation-gas chromatography-mass spectrometry (VD-GC-MS)

    was developed for determining volatile organo-metalloid contaminants in bio-solid materials. Method

    performance was evaluated for dimethylselenide (DMSe), dimethyldisel...

  16. Detection of argan oil adulteration with vegetable oils by high-performance liquid chromatography-evaporative light scattering detection.

    PubMed

    Salghi, Rachid; Armbruster, Wolfgang; Schwack, Wolfgang

    2014-06-15

    Triacylglycerol profiles were selected as indicator of adulteration of argan oils to carry out a rapid screening of samples for the evaluation of authenticity. Triacylglycerols were separated by high-performance liquid chromatography-evaporative light scattering detection. Different peak area ratios were defined to sensitively detect adulteration of argan oil with vegetable oils such as sunflower, soy bean, and olive oil up to the level of 5%. Based on four reference argan oils, mean limits of detection and quantitation were calculated to approximately 0.4% and 1.3%, respectively. Additionally, 19 more argan oil reference samples were analysed by high-performance liquid chromatography-refractive index detection, resulting in highly comparative results. The overall strategy demonstrated a good applicability in practise, and hence a high potential to be transferred to routine laboratories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Approaches of aroma extraction dilution analysis (AEDA) for headspace solid phase microextraction and gas chromatography-olfactometry (HS-SPME-GC-O): Altering sample amount, diluting the sample or adjusting split ratio?

    PubMed

    Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming

    2015-11-15

    Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.

  18. A green method for the quantification of plastics-derived endocrine disruptors in beverages by chemometrics-assisted liquid chromatography with simultaneous diode array and fluorescent detection.

    PubMed

    Vidal, Rocío B Pellegrino; Ibañez, Gabriela A; Escandar, Graciela M

    2016-10-01

    The aim of this study was to develop a novel analytical method for the determination of bisphenol A, nonylphenol, octylphenol, diethyl phthalate, dibutyl phthalate and diethylhexyl phthalate, compounds known for their endocrine-disruptor properties, based on liquid chromatography with simultaneous diode array and fluorescent detection. Following the principles of green analytical chemistry, solvent consumption and chromatographic run time were minimized. To deal with the resulting incomplete resolution in the chromatograms, a second-order calibration was proposed. Second-order data (elution time-absorbance wavelength and elution time-fluorescence emission wavelength matrices) were obtained and processed by multivariate curve resolution-alternating least-squares (MCR-ALS). Applying MCR-ALS allowed quantification of the analytes even in the presence of partially overlapped chromatographic and spectral bands among these compounds and the potential interferents. The obtained results from the analysis of beer, wine, soda, juice, water and distilled beverage samples were compared with gas chromatography-mass spectrometry (GC-MS). Limits of detection (LODs) in the range 0.04-0.38ngmL(-1) were estimated in real samples after a very simple solid-phase extraction. All the samples were found to contain at least three EDs, in concentrations as high as 334ngmL(-1). Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Development of radiation indicators to distinguish between irradiated and non-irradiated herbal medicines using HPLC and GC-MS.

    PubMed

    Kim, Min Jung; Ki, Hyeon A; Kim, Won Young; Pal, Sukdeb; Kim, Byeong Keun; Kang, Woo Suk; Song, Joon Myong

    2010-09-01

    The effects of high dose γ-irradiation on six herbal medicines were investigated using gas chromatography-mass spectrometry (GC/MS) and high-performance liquid chromatography (HPLC). Herbal medicines were irradiated at 0-50 kGy with (60)Co irradiator. HPLC was used to quantify changes of major components including glycyrrhizin, cinnamic acid, poncirin, hesperidin, berberine, and amygdalin in licorice, cinnamon bark, poncirin immature fruit, citrus unshiu peel, coptis rhizome, and apricot kernel. No significant differences were found between gamma-irradiated and non-irradiated samples with regard to the amounts of glycyrrhizin, berberine, and amygdalin. However, the contents of cinnamic acid, poncirin, and hesperidin were increased after irradiation. Volatile compounds were analyzed by GC/MS. The relative proportion of ketone in licorice was diminished after irradiation. The relative amount of hydrocarbons in irradiated cinnamon bark and apricot kernel was higher than that in non-irradiated samples. Therefore, ketone in licorice and hydrocarbons in cinnamon bark and apricot kernel can be considered radiolytic markers. Three unsaturated hydrocarbons, i.e., 1,7,10-hexadecatriene, 6,9-heptadecadiene, and 8-heptadecene, were detected only in apricot kernels irradiated at 25 and 50 kGy. These three hydrocarbons could be used as radiolytic markers to distinguish between irradiated (>25 kGy) and non-irradiated apricot kernels.

  20. Characterisation of gunshot residue from three ammunition types using suppressed anion exchange chromatography.

    PubMed

    Gilchrist, Elizabeth; Jongekrijg, Fleur; Harvey, Laura; Smith, Norman; Barron, Leon

    2012-09-10

    Gunshot residue (GSR) is commonly analysed in forensic casework using either scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDX) or gas chromatography-mass spectrometry (GC-MS). Relatively little work has been reported on the post-discharge GSR content of non-metallic inorganic or low molecular weight organic anions to distinguish between different ammunition types. The development of an analytical method using suppressed micro-bore anion exchange chromatography (IC) is presented for the analysis of GSR. A hydroxide gradient was optimised for the separation of 19 forensically relevant organic and inorganic anions in <23min and sensitivities of the order of 0.12-3.52ng of anion detected for all species were achieved. Along with an optimised extraction procedure, this method was applied to the analysis of post-ignition residues from three selected ammunition types. By profiling and comparing the anionic content in each ammunition residue, the possibility to distinguish between each type using their anionic profiles and absolute weight is presented. The potential for interference is also discussed with respect to sample types which are typically problematic in the analysis of GSR using SEM-EDX and GC-MS. To the best of our knowledge this represents the first study on the analysis of inorganic anions in GSR using suppressed ion chromatography. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Identification of Major Histocompatibility Complex-Regulated Body Odorants by Statistical Analysis of a Comparative Gas Chromatography/Mass Spectrometry Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willse, Alan R.; Belcher, Ann; Preti, George

    2005-04-15

    Gas chromatography (GC), combined with mass spectrometry (MS) detection, is a powerful analytical technique that can be used to separate, quantify, and identify volatile compounds in complex mixtures. This paper examines the application of GC-MS in a comparative experiment to identify volatiles that differ in concentration between two groups. A complex mixture might comprise several hundred or even thousands of volatile compounds. Because their number and location in a chromatogram generally are unknown, and because components overlap in populous chromatograms, the statistical problems offer significant challenges beyond traditional two-group screening procedures. We describe a statistical procedure to compare two-dimensional GC-MSmore » profiles between groups, which entails (1) signal processing: baseline correction and peak detection in single ion chromatograms; (2) aligning chromatograms in time; (3) normalizing differences in overall signal intensities; and (4) detecting chromatographic regions that differ between groups. Compared to existing approaches, the proposed method is robust to errors made at earlier stages of analysis, such as missed peaks or slightly misaligned chromatograms. To illustrate the method, we identify differences in GC-MS chromatograms of ether-extracted urine collected from two nearly identical inbred groups of mice, to investigate the relationship between odor and genetics of the major histocompatibility complex.« less

  2. Simultaneous determination of zearalenone and its derivatives in edible vegetable oil by gel permeation chromatography and gas chromatography-triple quadrupole mass spectrometry.

    PubMed

    Qian, Mingrong; Zhang, Hu; Wu, Liqin; Jin, Nuo; Wang, Jianmei; Jiang, Kezhi

    2015-01-01

    A sensitive gas chromatographic-triple quadrupole mass spectrometric (GC-QqQ MS) analytical method, for the determination of zearalenone and its five derivatives in edible vegetable oil, was developed. After the vegetable oil samples were prepared using gel permeation chromatography, the eluent was collected, evaporated and dried with nitrogen gas. The residue was silylated with N,O-bis-trimethylsilyltrifluoroacetamide, containing 1% trimethylchlorosilane. GC-QqQ MS was performed in the reaction-monitoring mode to confirm and quantify mycotoxins in vegetable oil. The limits of quantitation were 0.03-0.2 μg kg(-1) for the six mycotoxins. The average recoveries, measured at 2, 20 and 200 μg kg(-1), were in the range 80.3-96.5%. Zearalenone was detected in the range 5.2-184.6 μg kg(-1) in nine maize oils and at 40.7 μg kg(-1) in a rapeseed oil from the local market. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Simple and Fast Sample Preparation Followed by Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS) for the Analysis of 2- and 4-Methylimidazole in Cola and Dark Beer.

    PubMed

    Choi, Sol Ji; Jung, Mun Yhung

    2017-04-01

    We have developed a simple and fast sample preparation technique in combination with a gas chromatography-tandem mass spectrometry (GC-MS/MS) for the quantification of 2-methylimidazole (2-MeI) and 4-methylimidazole (4-MeI) in colas and dark beers. Conventional sample preparation technique for GC-MS requires laborious and time-consuming steps consisting of sample concentration, pH adjustment, ion pair extraction, centrifugation, back-extraction, centrifugation, derivatization, and extraction. Our sample preparation technique consists of only 2 steps (in situ derivation and extraction) which requires less than 3 min. This method provided high linearity, low limit of detection and limit of quantification, high recovery, and high intra- and interday repeatability. It was found that internal standard method with diluted stable isotope (4-MeI-d 6 ) and 2-ethylimidazole (2-EI) could not correctly compensate the matrix effects. Thus, standard addition technique was used for the quantification of 2- and 4-MeI. The established method was successfully applied to colas and dark beers for the determination of 2-MeI and 4-MeI. The 4-MeI contents in colas and dark beers ranged from 8 to 319 μg/L and from trace to 417 μg/L, respectively. Small quantity (0 to 8 μg/L) of 2-MeI was found only in dark beers. The contents of 4-MeI (22 μg/L) in colas obtained from fast food restaurants were significantly lower than those (177 μg/L) in canned or bottled colas. © 2017 Institute of Food Technologists®.

  4. Determination of airborne carbonyls: comparison of a thermal desorption/GC method with the standard DNPH/HPLC method.

    PubMed

    Ho, Steven Sai Hang; Yu, Jian Zhen

    2004-02-01

    The standard method for the determination of gaseous carbonyls is to collect carbonyls onto 2,4-dinitrophenyl hydrazine (DNPH) coated solid sorbent followed by solvent extraction of the solid sorbent and analysis of the derivatives using high-pressure liquid chromatography (HPLC). This paper describes a newly developed approach that involves collection of the carbonyls onto pentafluorophenyl hydrazine (PFPH) coated solid sorbents followed by thermal desorption and gas chromatographic (GC) analysis of the PFPH derivatives with mass spectrometric (MS) detection. Sampling tubes loaded with 510 nmol of PFPH on Tenax sorbent effectively collect gaseous carbonyls, including formaldehyde, acetaldehyde, propanal, butanal, heptanal, octanal, acrolein, 2-furfural, benzaldehyde, p-tolualdehyde, glyoxal, and methylglyoxal, at a flow rate of at least up to 100 mL/min. All of the tested carbonyls are shown to have method detection limits (MDLs) of subnanomoles per sampling tube, corresponding to air concentrations of <0.3 ppbv for a sampled volume of 24 L. These limits are 2-12 times lower than those that can be obtained using the DNPH/HPLC method. The improvement of MDLs is especially pronounced for carbonyls larger than formaldehyde and acetaldehyde. The PFPH/GC method also offers better peak separation and more sensitive and specific detection through the use of MS detection. Comparison studies on ambient samples and kitchen exhaust samples have demonstrated that the two methods do not yield systematic differences in concentrations of the carbonyls that are above their respective MDLs in both methods, including formaldehyde, acetaldehyde, acrolein, and butanal. The lower MDLs afforded by the PFPH/ GC method also enable the determination of a few more carbonyls in both applications.

  5. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    EPA Science Inventory

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  6. Characterization and Comparison of Fast Pyrolysis Bio-oils from Pinewood, Rapeseed Cake, and Wheat Straw Using 13C NMR and Comprehensive GC × GC.

    PubMed

    Negahdar, Leila; Gonzalez-Quiroga, Arturo; Otyuskaya, Daria; Toraman, Hilal E; Liu, Li; Jastrzebski, Johann T B H; Van Geem, Kevin M; Marin, Guy B; Thybaut, Joris W; Weckhuysen, Bert M

    2016-09-06

    Fast pyrolysis bio-oils are feasible energy carriers and a potential source of chemicals. Detailed characterization of bio-oils is essential to further develop its potential use. In this study, quantitative 13 C nuclear magnetic resonance ( 13 C NMR) combined with comprehensive two-dimensional gas chromatography (GC × GC) was used to characterize fast pyrolysis bio-oils originated from pinewood, wheat straw, and rapeseed cake. The combination of both techniques provided new information on the chemical composition of bio-oils for further upgrading. 13 C NMR analysis indicated that pinewood-based bio-oil contained mostly methoxy/hydroxyl (≈30%) and carbohydrate (≈27%) carbons; wheat straw bio-oil showed to have high amount of alkyl (≈35%) and aromatic (≈30%) carbons, while rapeseed cake-based bio-oil had great portions of alkyl carbons (≈82%). More than 200 compounds were identified and quantified using GC × GC coupled to a flame ionization detector (FID) and a time of flight mass spectrometer (TOF-MS). Nonaromatics were the most abundant and comprised about 50% of the total mass of compounds identified and quantified via GC × GC. In addition, this analytical approach allowed the quantification of high value-added phenolic compounds, as well as of low molecular weight carboxylic acids and aldehydes, which exacerbate the unstable and corrosive character of the bio-oil.

  7. Characterization and Comparison of Fast Pyrolysis Bio-oils from Pinewood, Rapeseed Cake, and Wheat Straw Using 13C NMR and Comprehensive GC × GC

    PubMed Central

    2016-01-01

    Fast pyrolysis bio-oils are feasible energy carriers and a potential source of chemicals. Detailed characterization of bio-oils is essential to further develop its potential use. In this study, quantitative 13C nuclear magnetic resonance (13C NMR) combined with comprehensive two-dimensional gas chromatography (GC × GC) was used to characterize fast pyrolysis bio-oils originated from pinewood, wheat straw, and rapeseed cake. The combination of both techniques provided new information on the chemical composition of bio-oils for further upgrading. 13C NMR analysis indicated that pinewood-based bio-oil contained mostly methoxy/hydroxyl (≈30%) and carbohydrate (≈27%) carbons; wheat straw bio-oil showed to have high amount of alkyl (≈35%) and aromatic (≈30%) carbons, while rapeseed cake-based bio-oil had great portions of alkyl carbons (≈82%). More than 200 compounds were identified and quantified using GC × GC coupled to a flame ionization detector (FID) and a time of flight mass spectrometer (TOF-MS). Nonaromatics were the most abundant and comprised about 50% of the total mass of compounds identified and quantified via GC × GC. In addition, this analytical approach allowed the quantification of high value-added phenolic compounds, as well as of low molecular weight carboxylic acids and aldehydes, which exacerbate the unstable and corrosive character of the bio-oil. PMID:27668136

  8. Gas chromatography/principal component similarity system for detection of E. coli and S. aureus contaminating salmon and hamburger.

    PubMed

    Nakai, S; Wang, Z H; Dou, J; Nakamura, S; Ogawa, M; Nakai, E; Vanderstoep, J

    1999-02-01

    Coho, Atlantic, Spring, and Sockeye salmon and five commercial samples of hamburger patties were analyzed by processing gas chromatography (GC) data of volatile compounds using the principal component similarity (PCS) technique. PCS scattergrams of the samples inoculated with Escherichia coli and Staphylococcus aureus followed by incubation showed the pattern-shift lines moving away from the data point for uninoculated, unincubated reference samples in different directions with increasing incubation time. When the PCS scattergrams were drawn for samples incubated overnight, the samples inoculated with the two bacterial species and the uninoculated samples appeared as three separated groups. This GC/PCS approach has the potential to ensure quality of samples by discriminating good samples from potentially spoiled samples. The latter may require further microbial assays to identify the bacteria species potentially contaminating foods.

  9. Androstadienetrione, a boldenone-like component, detected in cattle faeces with GC-MS(n) and LC-MS(n).

    PubMed

    Poelmans, S; De Wasch, K; Noppe, H; Van Hoof, N; Van de Wiele, M; Courtheyn, D; Gillis, W; Vanthemsche, P; Janssen, C R; De Brabander, H F

    2005-09-01

    Boldenone (1,4-androstadiene-17-ol-3-one, Bol) has been the subject of a heated debate because of ongoing confusion about its endogenous or exogenous origin when detected in one of its forms in faecal or urine samples from cattle. An expert report was recently written on the presence and metabolism of Bol in various animal species. Androstadienedione (ADD) is a direct precursor of 17beta-boldenone (betaBol). It is a 3,17-dione; ssBol is a 17-ol-3-one. Not much is published on 1,4-androstadiene-3,17-diol, which is a 3,17-diol (ADL). If animals were exposed for a longer period to one of these analytes, a metabolic pathway would be initiated to eliminate these compounds. Similar to recent testosterone metabolism studies in the aquatic invertebrate Neomysis integer, ADD, ssBol and ADL could also be eliminated as hydroxymetabolites after exposure. The presence of 11-keto-steroids or 11-hydroxy-metabolites in faecal samples can interfere with a confirmation method by gas chromatography-negative chemical ionization mass spectrometry (GC-NCI-MS), after oxidation of corticosteroids with a double bond in the A-ring (e.g. prednisolone or its metabolite prednisone). The presence of androstadienetrione (ADT) in faecal samples of cattle has never been reported. The origin of its presence can be explained through different pathways, which are presented in this paper.

  10. Screening of inorganic gases released from firework-rockets by a gas chromatography/whistle-accelerometer method.

    PubMed

    Chen, Kuan-Fu; Wu, Hui-Hsin; Lin, Chien-Hung; Lin, Cheng-Huang

    2013-08-30

    The use of an accelerometer for detecting inorganic gases in gas chromatography (GC) is described. A milli-whistle was connected to the outlet of the GC capillary and was used instead of a classical GC detector. When the GC carrier gases and the sample gases pass through the milli-whistle, a sound is produced, leading to vibrational changes, which can be recorded using an accelerometer. Inorganic gases, including SO2, N2 and CO2, which are released from traditional Chinese firework-rockets at relatively high levels as the result of burning the propellant and explosive material inside could be rapidly determined using the GC/whistle-accelerometer system. The method described herein is safe, the instrumentation is compact and has potential to be modified so as to be portable for use in the field. It also can be used in conjunction with FID (flame ionization detector) or TCD (thermal conductivity detector), in which either no response for FID (CO2, N2, NO2, SO2, etc.) or helium gas is needed for TCD, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Simultaneous determination of rhamnose, xylitol, arabitol, fructose, glucose, inositol, sucrose, maltose in jujube (Zizyphus jujube Mill.) extract: comparison of HPLC-ELSD, LC-ESI-MS/MS and GC-MS.

    PubMed

    Sun, Shihao; Wang, Hui; Xie, Jianping; Su, Yue

    2016-01-01

    Jujube extract is commonly used as a food additive and flavoring. The sensory properties of the extract, especially sweetness, are a critical factor determining the product quality and therefore affecting consumer acceptability. Small molecular carbohydrates make major contribution to the sweetness of the jujube extract, and their types and contents in the extract have direct influence on quality of the product. So, an appropriate qualitative and quantitative method for determination of the carbohydrates is vitally important for quality control of the product. High performance liquid chromatography-evaporative light scattering detection (HPLC-ELSD), liquid chromatography-electronic spay ionization tandem mass spectrometry (LC-ESI-MS/MS), and gas chromatography-mass spectrometry (GC-MS) methods have been developed and applied to determining small molecular carbohydrates in jujube extract, respectively. Eight sugars and alditols were identified from the extract, including rhamnose, xylitol, arabitol, fructose, glucose, inositol, sucrose, and maltose. Comparisons were carried out to investigate the performance of the methods. Although the methods have been found to perform satisfactorily, only three sugars (fructose, glucose and inositol) could be detected by all these methods. Meanwhile, a similar quantitative result for the three sugars can be obtained by the methods. Eight sugars and alditols in the jujube extract were determined by HPLC-ELSD, LC-ESI-MS/MS and GC-MS, respectively. The LC-ELSD method and the LC-ESI-MS/MS method with good precision and accuracy were suitable for quantitative analysis of carbohydrates in jujube extract; although the performance of the GC-MS method for quantitative analysis was inferior to the other methods, it has a wider scope in qualitative analysis. A multi-analysis technique should be adopted in order to obtain complete constituents of about the carbohydrates in jujube extract, and the methods should be employed according to the

  12. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    PubMed

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air.

  13. Mixture model normalization for non-targeted gas chromatography/mass spectrometry metabolomics data.

    PubMed

    Reisetter, Anna C; Muehlbauer, Michael J; Bain, James R; Nodzenski, Michael; Stevens, Robert D; Ilkayeva, Olga; Metzger, Boyd E; Newgard, Christopher B; Lowe, William L; Scholtens, Denise M

    2017-02-02

    Metabolomics offers a unique integrative perspective for health research, reflecting genetic and environmental contributions to disease-related phenotypes. Identifying robust associations in population-based or large-scale clinical studies demands large numbers of subjects and therefore sample batching for gas-chromatography/mass spectrometry (GC/MS) non-targeted assays. When run over weeks or months, technical noise due to batch and run-order threatens data interpretability. Application of existing normalization methods to metabolomics is challenged by unsatisfied modeling assumptions and, notably, failure to address batch-specific truncation of low abundance compounds. To curtail technical noise and make GC/MS metabolomics data amenable to analyses describing biologically relevant variability, we propose mixture model normalization (mixnorm) that accommodates truncated data and estimates per-metabolite batch and run-order effects using quality control samples. Mixnorm outperforms other approaches across many metrics, including improved correlation of non-targeted and targeted measurements and superior performance when metabolite detectability varies according to batch. For some metrics, particularly when truncation is less frequent for a metabolite, mean centering and median scaling demonstrate comparable performance to mixnorm. When quality control samples are systematically included in batches, mixnorm is uniquely suited to normalizing non-targeted GC/MS metabolomics data due to explicit accommodation of batch effects, run order and varying thresholds of detectability. Especially in large-scale studies, normalization is crucial for drawing accurate conclusions from non-targeted GC/MS metabolomics data.

  14. Multidimensional and comprehensive two-dimensional gas chromatography of dichloromethane soluble products from a high sulfur Jordanian oil shale.

    PubMed

    Amer, Mohammad W; Mitrevski, Blagoj; Jackson, W Roy; Chaffee, Alan L; Marriott, Philip J

    2014-03-01

    A high sulfur Jordanian oil shale was converted into liquid hydrocarbons by reaction at 390 °C under N2, and the dichloromethane soluble fraction of the products was isolated then analyzed by using gas chromatography (GC). Comprehensive two-dimensional GC (GC×GC) and multidimensional GC (MDGC) were applied for component separation on a polar - non-polar column set. Flame-ionization detection (FID) was used with GC×GC for general sample profiling, and mass spectrometry (MS) for component identification in MDGC. Multidimensional GC revealed a range of thiophenes (th), benzothiophenes (bth) and small amounts of dibenzothiophenes (dbth) and benzonaphthothiophenes (bnth). In addition, a range of aliphatic alkanes and cycloalkanes, ethers, polar single ring aromatic compounds and small amounts of polycyclic aromatics were also identified. Some of these compound classes were not uniquely observable by conventional 1D GC, and certainly this is true for many of their minor constituent members. The total number of distinct compounds was very large (ca.>1000). GC×GC was shown to be appropriate for general sample profiling, and MDGC-MS proved to be a powerful technique for the separation and identification of sulfur-containing components and other polar compounds. © 2013 Published by Elsevier B.V.

  15. Development and Applications of Portable Gas Chromatography-Mass Spectrometry for Emergency Responders, the Military, and Law-Enforcement Organizations.

    PubMed

    Leary, Pauline E; Dobson, Gareth S; Reffner, John A

    2016-05-01

    Portable gas chromatography-mass spectrometry (GC-MS) systems are being deployed for field use, and are designed with this goal in mind. Performance characteristics of instruments that are successful in the field are different from those of equivalent technologies that are successful in a laboratory setting. These field-portable systems are extending the capabilities of the field user, providing investigative leads and confirmatory identifications in real time. Many different types of users benefit from the availability of this technology including emergency responders, the military, and law-enforcement organizations. This manuscript describes performance characteristics that are important for field-portable instruments, especially field-portable GC-MS systems, and demonstrates the value of this equipment to the disciplines of explosives investigations, fire investigations, and counterfeit-drug detection. This paper describes the current state of portable GC-MS technology, including a review of the development of portable GC-MS, as well as a demonstration of the value of this capability using different examples. © The Author(s) 2016.

  16. Rapid and easy identification of Illicium verum Hook. f. and its adulterant Illicium anisatum Linn. by fluorescent microscopy and gas chromatography.

    PubMed

    Joshi, Vaishali C; Srinivas, Pullela V; Khan, Ikhlas A

    2005-01-01

    Illicium verum Hook. f. is used as an herbal tea to treat colic pain in infants. Reports suggest that Star anise herbal tea may be adulterated with Illicium anisatum Linn. A short and rapid method using microscopy and gas chromatography (GC) was developed to detect I. anisatum Linn., an adulterant in the powdered mixture of I. verum. Anatomical differences in the epicarp cells of I. verum and I. anisatum fruits were clearly defined as examined under fluorescent microscopy and scanning electron microscopy. A GC method was developed for quick identification of possible I. anisatum adulteration with I. verum.

  17. Quantitation of monomers in poly(glyerol-co-diacid) gels using gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The validation of a gas chromatography (GC) method developed to quantify amounts of starting material from the synthesis of hyperbranched polymers made from glycerol and either succinic acid, glutaric acid, or azelaic acid is described. The GC response to concentration was linear for all starting r...

  18. Chemical Detection and Identification Techniques for Exobiology Flight Experiments

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Sheverev, Valery A.; Khromov, Nikolai A.

    2002-01-01

    Exobiology flight experiments require highly sensitive instrumentation for in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical Instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. Advances in technology may be achieved by increasing the amount of information acquired by a given technique with greater analytical capabilities and miniaturization of proven terrestrial technology. We describe here methods to develop analytical instruments for the detection and identification of a wide range of chemical species using Gas Chromatography. These efforts to expand the analytical capabilities of GC technology are focused on the development of detectors for the GC which provide sample identification independent of the GC retention time data. A novel new approach employs Penning Ionization Electron Spectroscopy (PIES).

  19. A practical approach to determination of laboratory GC-MS limits of detection.

    PubMed

    Underwood, P J; Kananen, G E; Armitage, E K

    1997-01-01

    Determination of limit of detection (LOD) values in a forensic laboratory serves a fundamental forensic requirement for assay performance. In addition to demonstrating assay capability, LOD values can also be used to fulfill certification requirements of a high-volume forensic drug laboratory. The LOD was defined as the lowest concentration of drug that the laboratory can detect in a specimen with forensic certainty at a minimum of 85% of the time. Overall batch acceptance criteria included acceptable quantitation of control materials (within 20% of target), acceptable chromatography (symmetry, peak integration, peak shape, peak, and baseline resolution), retention time within +/-1% of the extracted standard, and mass ion ratios within +/-20% of the extracted standard mass ion ratios. Individual specimen acceptance criteria were the same as the batch acceptance criteria excluding the quantitation requirement. Data were collected from all instruments on different runs. A minimum of ten data points was required for each certified instrument, and a minimum of 85% of data points was acceptable. Quantitation within +/-20% of the LOD concentration was not required, but acceptable mass ratios were required. Data points with poor chromatography (internal standard failed mass ratios; interference of the baseline, for example, shoulders; asymmetry; and baseline resolution) was omitted from the acceptable rate calculation. Data points with good chromatography with failed mass ion ratios were included in the acceptable rate calculation. With these criteria, we established the following LODs: 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid, 2 ng/mL; benzoylecgonine, 5 ng/mL; phencyclidine, 2.5 ng/mL; amphetamine, 150 ng/mL; methamphetamine, 100 ng/mL; codeine, 500 ng/mL; and morphine, 1000 ng/mL.

  20. "One-pot" ethyl chloroformate derivatization and liquid-liquid extraction of reduced glutathione in erythrocyte and its quantitative GC-MS analysis.

    PubMed

    Manca, Alessandra; Alladio, Eugenio; Massarenti, Paola; Puccinelli, M Paola; De Francesco, Antonella; Del Grosso, Erika; Mengozzi, Giulio; Pazzi, Marco; Vincenti, Marco

    2017-12-01

    A simple "one-pot" derivatization and liquid-liquid extraction (LLE) procedure was developed for GC-MS analysis of reduced glutathione (GSH) analysis in erythrocytes. The metabolite was extracted by 5% (w/v) TCA, the supernatant treated with ECF and ethanol-pyridine media, the derivative separated and detected by gas chromatography-mass spectrometry using a short non-polar capillary GC column at a high column-head pressure. Total analysis time was 11min. The process was optimized by a Design of Experiment. The method was validated showing a good linearity over the 25.4-813.4μM concentration range, providing satisfactory results in terms of intra-day and inter-day precision as well as an optimal accuracy. The new method was evaluated in a pilot study involving patients with severe protein malnutrition. Comparison of this group with a group of healthy subjects revealed significantly lower GSH concentrations in erythrocytes in the former, thus proving that the described GC-MS method could be employed for fast and simple GSH analysis in clinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Supercritical Fluid Chromatography--Theoretical Background and Applications on Natural Products.

    PubMed

    Hartmann, Anja; Ganzera, Markus

    2015-11-01

    The use of supercritical fluid chromatography for natural product analysis as well as underlying theoretical mechanisms and instrumental requirements are summarized in this review. A short introduction focusing on the historical development of this interesting separation technique is followed by remarks on the current instrumental design, also describing possible detection modes and useable stationary phases. The overview on relevant applications is grouped based on their basic intention, may it be (semi)preparative or purely analytical. They indicate that supercritical fluid chromatography is still primarily considered for the analysis of nonpolar analytes like carotenoids, fatty acids, or terpenes. The low polarity of supercritical carbon dioxide, which is used with modifiers almost exclusively as a mobile phase today, combined with high efficiency and fast separations might explain the popularity of supercritical fluid chromatography for the analysis of these compounds. Yet, it has been shown that more polar natural products (e.g., xanthones, flavonoids, alkaloids) are separable too, with the same (if not superior) selectivity and reproducibility than established approaches like HPLC or GC. Georg Thieme Verlag KG Stuttgart · New York.

  2. THE DETERMINATION OF NON-PESTICIDAL AND PESTICIDAL ORGANOTIN COMPOUNDS IN WATER BY GAS CHROMATOGRAPHY WITH [PULSED] FLAME PHOTOMETRIC DETECTION (GS/PFPD): THE EFFECTS OF "MASS" DISCRIMINATION

    EPA Science Inventory

    Capillary gas chromatography with GC/PFPD was used in the development of analytical methodology for determining both non-pesticidal and pesticidal organotin compounds in drinking water and other aqueous matrices. The method involves aqueous ethylation of organotin analytes with ...

  3. Influence of harvest maturity and fruit logistics on pineapple (Ananas comosus [L.] Merr.) volatiles assessed by headspace solid phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS).

    PubMed

    Steingass, Christof B; Grauwet, Tara; Carle, Reinhold

    2014-05-01

    Profiling of volatiles from pineapple fruits was performed at four ripening stages using headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS). In total, 142 volatiles were detected, of which 132 were identified. Multivariate data analysis was carried out to assess the effect of post-harvest storage on volatiles composition of green-ripe sea-freighted pineapple in comparison to air-freighted fruits harvested at full maturity. The latter fruits were characterised by volatiles described as potent odorants in pineapples, such as δ-octalactone, γ-lactones, 1-(E,Z)-3,5-undecatriene and 1,3,5,8-undecatetraene, as well as various methyl esters. In contrast, post-harvest storage of green-ripe sea-freighted fruits resulted in an increased formation of ethyl esters, acetates, acetoxy esters and alcohols, thus allowing the authentication of sea- and air-freighted pineapples, respectively. Particularly, compounds presumably derived from methyl-branched amino acid catabolism were identified in the fruits at later post-harvest stages. In addition, physicochemical traits were determined to characterise the fruit maturity stages. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development

  5. Detecting a wide range of environmental contaminants in human blood samples--combining QuEChERS with LC-MS and GC-MS methods.

    PubMed

    Plassmann, Merle M; Schmidt, Magdalena; Brack, Werner; Krauss, Martin

    2015-09-01

    Exposure to environmental pollution and consumer products may result in an uptake of chemicals into human tissues. Several studies have reported the presence of diverse environmental contaminants in human blood samples. However, previously developed multi-target methods for the analysis of human blood include a fairly limited amount of compounds stemming from one or two related compound groups. Thus, the sample preparation method QuEChERS (quick easy cheap effective rugged and safe) was tested for the extraction of 64 analytes covering a broad compound domain followed by detection using liquid and gas chromatography coupled to mass spectrometry (LC- and GC-MS). Forty-seven analytes showed absolute recoveries above 70% in the first QuEChERS step, being a simple liquid-liquid extraction (LLE) using acetonitrile and salt. The second QuEChERS step, being a dispersive solid phase extraction, did not result in an overall improvement of recoveries or removal of background signals. Using solely the LLE step, eight analytes could subsequently be detected in human blood samples from the German Environmental Specimen Bank. Using a LC-multiple reaction monitoring (MRM) method with a triple quadrupole instrument, better recoveries were achieved than with an older LC-high-resolution (HR) MS full scan orbitrap instrument, which required a higher concentration factor of the extracts. However, the application of HRMS full scan methods could be used for the detection of additional compounds retrospectively.

  6. Quantification of plasma myo-inositol using gas chromatography-mass spectrometry.

    PubMed

    Guo, Jin; Shi, Yingfei; Xu, Chengbao; Zhong, Rugang; Zhang, Feng; Zhang, Ting; Niu, Bo; Wang, Jianhua

    2016-09-01

    Myo-inositol (MI) deficiency is associated with an increased risk for neural tube defects (NTDs), mental disorders and metabolic diseases. We developed a gas chromatography-mass spectrometry (GC-MS) method to detect MI in human plasma, which was accurate, relatively efficient and convenient for clinical application. An external standard method was used for determination of plasma MI. Samples were analyzed by GC-MS after derivatization. The stable-isotope labeled internal standard approach was used to validate the method's accuracy. Alpha fetal protein (AFP) was detected by chemiluminescence immunoassay. The method was validated by determining the linearity, sensitivity and recovery rate. There was a good agreement between the internal standard approach and the present method. The NTD-affected pregnancies showed lower plasma MI (P=0.024) and higher AFP levels (P=0.001) than control. Maternal MI level showed a better discrimination in spina bifida subgroup, while AFP level showed a better discrimination in anencephaly subgroup after stratification analysis. We developed a sensitive and reliable method for the detection of clinical plasma MI, which might be a marker for NTDs screening, and established fundamental knowledge for clinical diagnosis and prevention for the diseases related to disturbed MI metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. An Exploration on the Suitability of Airborne Carbonyl Compounds Analysis in relation to Differences in Instrumentation (GC-MS versus HPLC-UV) and Standard Phases (Gas versus Liquid)

    PubMed Central

    Kim, Ki-Hyun; Szulejko, Jan E.; Kim, Yong-Hyun; Lee, Min-Hee

    2014-01-01

    The relative performance figure of merits was investigated for the two most common analytical methods employed for carbonyl compounds (CC), for example, between high performance liquid chromatography (HPLC)-UV detector (with 2,4-dinitrophenylhydrazine (DNPH) derivatization) and thermal desorption (TD)-gas chromatography (GC)-mass spectrometry (MS) (without derivatization). To this end, the suitability of each method is assessed by computing the relative recovery (RR) between the gas- and liquid-phase standards containing a suite of CC such as formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA), and valeraldehyde (VA) along with benzene (B) as a recovery reference for the GC method. The results confirm that a TD-GC-MS is advantageous to attain the maximum recovery for the heavier CCs (i.e., with molecular weights (MW) above BA−MW ≥ 74). On the other hand, the HPLC-UV is favorable for the lighter CCs (like FA and AA) with the least bias. Such compound-specific responses for each platform are validated by relative ordering of CCs as a function of response factor (RF), method detection limit (MDL), and recovery pattern. It is thus desirable to understand the advantages and limitations of each method to attain the CC data with the least experimental bias. PMID:24719571

  8. [Recent advances in analysis of petroleum geological samples by comprehensive two-dimensional gas chromatography].

    PubMed

    Gao, Xuanbo; Chang, Zhenyang; Dai, Wei; Tong, Ting; Zhang, Wanfeng; He, Sheng; Zhu, Shukui

    2014-10-01

    Abundant geochemical information can be acquired by analyzing the chemical compositions of petroleum geological samples. The information obtained from the analysis provides scientifical evidences for petroleum exploration. However, these samples are complicated and can be easily influenced by physical (e. g. evaporation, emulsification, natural dispersion, dissolution and sorption), chemical (photodegradation) and biological (mainly microbial degradation) weathering processes. Therefore, it is very difficult to analyze the petroleum geological samples and they cannot be effectively separated by traditional gas chromatography/mass spectrometry. A newly developed separation technique, comprehensive two-dimensional gas chromatography (GC x GC), has unique advantages in complex sample analysis, and recently it has been applied to petroleum geological samples. This article mainly reviews the research progres- ses in the last five years, the main problems and the future research about GC x GC applied in the area of petroleum geology.

  9. Determination of guaifenesin in human serum by capillary gas chromatography and electron capture detection.

    PubMed

    Sharaf, Maged H M; Stiff, Dwight D

    2004-06-29

    A method for the quantitation of guaifenesin in human serum has been developed and validated. The procedure involves liquid-liquid extraction of the serum sample in the presence of mephenesin as an internal standard, followed by derivatization and analysis using capillary gas chromatography (GC) and electron capture detection (ECD). Different solvents were tested for extraction of guaifenesin from serum. n-Hexane/dichloromethane (1:1, v/v) gave the highest recovery and the lowest background and was chosen as the extraction solvent. After extraction, the residue of guaifenesin was derivatized at 60 degrees C for 30 min, with trifluoroacetic acid anhydride (TFAA) in toluene in the presence of pyridine. Excess trifluoroacetic acid anhydride was removed using dilute solution of ammonium hydroxide. The method proved to be linear over the range of 25.0-1000 ng/ml. Recovery of guaifenesin from spiked samples was consistent, averaging 75.5% at 50.0 ng/ml with a range of 72.0-80.0% (N = 8 determinations) and averaging 78% at 800 ng/ml with a range of 76.0-81.0% (N = 8 determinations). The internal standard recovery was also consistent averaging 72.8% with a range of 67.0-76.0% (N = 16 determinations). Copyright 2004 Elsevier B.V.

  10. Development and validation of an universal interface for compound-specific stable isotope analysis of chlorine (37Cl/35Cl) by GC-high-temperature conversion (HTC)-MS/IRMS.

    PubMed

    Renpenning, Julian; Hitzfeld, Kristina L; Gilevska, Tetyana; Nijenhuis, Ivonne; Gehre, Matthias; Richnow, Hans-Hermann

    2015-03-03

    A universal application of compound-specific isotope analysis of chlorine was thus far limited by the availability of suitable analysis techniques. In this study, gas chromatography in combination with a high-temperature conversion interface (GC-HTC), converting organic chlorine in the presence of H2 to gaseous HCl, was coupled to a dual-detection system, combining an ion trap mass spectrometer (MS) and isotope-ratio mass spectrometer (IRMS). The combination of the MS/IRMS detection enabled a detailed characterization, optimization, and online monitoring of the high-temperature conversion process via ion trap MS as well as a simultaneous chlorine isotope analysis by the IRMS. Using GC-HTC-MS/IRMS, chlorine isotope analysis at optimized conversion conditions resulted in very accurate isotope values (δ(37)Cl(SMOC)) for measured reference material with known isotope composition, including chlorinated ethylene, chloromethane, hexachlorocyclohexane, and trichloroacetic acids methyl ester. Respective detection limits were determined to be <15 nmol Cl on column with achieved precision of <0.3‰.

  11. Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC).

    PubMed

    de Jager, L S; Andrews, A R

    2000-11-01

    A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.

  12. Identification of terpenes and essential oils by means of static headspace gas chromatography-ion mobility spectrometry.

    PubMed

    Rodríguez-Maecker, Roman; Vyhmeister, Eduardo; Meisen, Stefan; Rosales Martinez, Antonio; Kuklya, Andriy; Telgheder, Ursula

    2017-11-01

    Static headspace gas chromatography-ion mobility spectrometry (SHS GC-IMS) is a relatively new analytical technique that has considerable potential for analysis of volatile organic compounds (VOCs). In this study, SHS GC-IMS was used for the identification of the major terpene components of various essential oils (EOs). Based on the data obtained from 25 terpene standards and 50 EOs, a database for fingerprint identification of characteristic terpenes and EOs was generated utilizing SHS GC-IMS for authenticity testing of fragrances in foods, cosmetics, and personal care products. This database contains specific normalized IMS drift times and GC retention indices for 50 terpene components of EOs. Initially, the SHS GC-IMS parameters, e.g., drift gas and carrier gas flow rates, drift tube, and column temperatures, were evaluated to determine suitable operating conditions for terpene separation and identification. Gas chromatography-mass spectrometry (GC-MS) was used as a reference method for the identification of terpenes in EOs. The fingerprint pattern based on the normalized IMS drift times and retention indices of 50 terpenes is presented for 50 EOs. The applicability of the method was proven on examples of ten commercially available food, cosmetic, and personal care product samples. The results confirm the suitability of SHS GC-IMS as a powerful analytical technique for direct identification of terpene components in solid and liquid samples without any pretreatment. Graphical abstract Fingerprint pattern identification of terpenes and essential oils using static headspace gas chromatography-ion mobility spectrometry.

  13. Solid-phase microextraction coupled to gas chromatography for the determination of 2,3-dimethyl-2,3-dinitrobutane as a marking agent for explosives.

    PubMed

    Li, Xiujuan; Zeng, Zhaorui; Zeng, Yi

    2007-06-15

    This paper investigates the detection of 2,3-dimethyl-2,3-dinitrobutane (DMNB), a marking agent in explosives, by gas chromatography (GC) with electron capture detection using solid-phase microextraction (SPME) as a sample preparation technique. The 25,27-dihydroxy-26,28-oxy (2',7'-dioxo-3',6'-diazaoctyl) oxy-p-tert-butylcalix[4]arene/hydroxy-terminated silicone oil coated fiber was highly sensitive to trap DMNB from ammonium nitrate matrix. The analysis was performed by extracting 2g of explosives for 30s at room temperature and then immediately introducing into the heated GC injector for 1min of thermal desorption. The method showed good linearity in the range from 0.01 to 1.0mug/g. The relative standard deviations for these extractions were <8%. The calculated limit of detection for DMNB (S/N=3) was 4.43x10(-4)mug/g, which illustrates that the proposed systems are suitable for explosive detection at trace level. This is the first report of an SPME-GC system shown to extract marking agent in explosives for subsequent detection in a simple, rapid, sensitive, and inexpensive manner.

  14. DETERMINATION OF CARBENDAZIM IN WATER BY HIGH-PERFORMANCE IMMUNOAFFINITY CHROMATOGRAPHY ON-LINE WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE-ARRAY OR MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    An automated method for the determination of carbendazim in water that combines high-performance immunoaffinity chromatography (HPIAC), high-performance liquid chromatography (HPLC) in the reversed-phase mode, and detection by either UV-Vis diode array detector (DAD) spectroscopy...

  15. Preliminary study of urine metabolism in type two diabetic patients based on GC-MS

    PubMed Central

    Zhang, Ning; Geng, Fang; Hu, Zhong-Hua; Liu, Bin; Wang, Ye-Qiu; Liu, Jun-Cen; Qi, Yong-Hua; Li, Li-Jing

    2016-01-01

    Objective: Comparative study of type 2 diabetes and healthy controls by metabolomics methods to explore the pathogenesis of Type II diabetes. Methods: Gas chromatography - mass spectrometry (GC-MS) with a variety of multivariate statistical analysis methods to the healthy control group 58 cases, 68 cases of Type II diabetes group were analyzed. Chromatographic conditions: DB-5MS column; the carrier gas He; flow rate of 1 mL·min-1, the injection volume 1 uL; split ratio is 100: 1. MS conditions: electron impact (EI) ion source, an auxiliary temperature of 280°C, the ion source 230°C, quadrupole 150°C; mass scan range 30~600 mAu. Results: Established analytical method based on urine metabolomics GC-MS of Type II diabetes, determine the urine succinic acid, L-leucine, L-isoleucine, tyrosine, slanine, acetoace acid, mannose, L-isoleucine, L-threonine, Phenylalanine, fructose, D-glucose, palmi acid, oleic acid and arachidonic acid were significantly were significantly changed. Conclusion: Based on metabolomics of GC-MS detection and analysis metabolites can be found differences between type 2 diabetes and healthy control group, PCA diagram can effectively distinguish Type II diabetes and healthy control group, with load diagrams and PLS-DA VIP value metabolite screening, the resulting differences in metabolic pathways involved metabolites, including amino acid metabolism, lipid metabolism, glucose metabolism and energy metabolism. PMID:27508010

  16. Facile on-site detection of substituted aromatic pollutants in water using thin layer chromatography combined with surface-enhanced Raman spectroscopy.

    PubMed

    Li, Dawei; Qu, Lulu; Zhai, Wenlei; Xue, Jinqun; Fossey, John S; Long, Yitao

    2011-05-01

    A novel facile method for on-site detection of substituted aromatic pollutants in water using thin layer chromatography (TLC) combined with surface-enhanced Raman spectroscopy (SERS) was explored. Various substituted aromatics in polluted water were separated by a convenient TLC protocol and then detected using a portable Raman spectrometer with the prepared silver colloids serving as SERS-active substrates. The effects of operating conditions on detection efficacy were evaluated, and the application of TLC-SERS to on-site detection of artificial and real-life samples of aromatics/polluted water was systematically investigated. It was shown that commercially available Si 60-F(254) TLC plates were suitable for separation and displayed low SERS background and good separation efficiency, 2 mM silver colloids, 20 mM NaCl (working as aggregating agent), 40 mW laser power, and 50 s intergration time were appropriate for the detection regime. Furthermore, qualitative and quantitative detection of most of substituted aromatic pollutants was found to be readily accomplished using the developed TLC-SERS technique, which compared well with GC-MS in terms of identification ability and detection accuracy, and a limit of detection (LOD) less than 0.2 ppm (even at ppb level for some analytes) could be achieved under optimal conditions. The results reveal that the presented convenient method could be used for the effective separation and detection of the substituted aromatic pollutants of water on site, thus reducing possible influences of sample transportation and contamination while shortening the overall analysis time for emergency and routine monitoring of the substituted aromatics/polluted water.

  17. A quantitative headspace-solid-phase microextraction-gas chromatography-flame ionization detector method to analyze short chain free fatty acids in rat feces.

    PubMed

    Fiorini, Dennis; Boarelli, Maria Chiara; Gabbianelli, Rosita; Ballini, Roberto; Pacetti, Deborah

    2016-09-01

    This study sought to develop and validate a quantitative method to analyze short chain free fatty acids (SCFAs) in rat feces by solid-phase microextraction and gas chromatography (SPME-GC) using the salt mixture ammonium sulfate and sodium dihydrogen phosphate as salting out agent. Conditioning and extraction time, linearity, limits of detection and quantification, repeatability, and recovery were evaluated. The proposed method allows quantification with improved sensitivity as compared with other methods exploiting SPME-GC. The method has been applied to analyze rat fecal samples, quantifying acetic, propionic, isobutyric, butyric, isopentanoic, pentanoic, and hexanoic acids. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Comprehensive sample analysis using high performance liquid chromatography with multi-detection.

    PubMed

    Pravadali, Sercan; Bassanese, Danielle N; Conlan, Xavier A; Francis, Paul S; Smith, Zoe M; Terry, Jessica M; Shalliker, R Andrew

    2013-11-25

    Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV-visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2'-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Unexpected dimerization of isoprene in a gas chromatography inlet. A study by gas chromatography/mass spectrometry coupling.

    PubMed

    Estevez, Yannick; Gardrat, Christian; Berthelot, Karine; Grau, Etienne; De Jeso, Bernard; Ouardad, Samira; Peruch, Frédéric

    2014-02-28

    During analysis of pure isoprene by gas chromatography/mass spectrometry (GC-MS) using a programmed temperature vaporization (PTV) inlet, the presence of several isoprene dimers was detected in the total ion chromatograms (TICs). This study intends to determine the part of the instrument where dimerization occurs and the relative importance of the dimer amounts under different experimental conditions. The reference thermal dimerization of isoprene gives four six-membered cyclic dimers and two eight-membered ones. In all samples containing different amounts of freshly distilled isoprene, only peaks corresponding to the former appeared in TICs. For the same temperature, their amounts increase as the concentration of injected isoprene increases. The main products are diprene (from 80 to 100%) of the total dimers and dipentene (from 1 to 14%). The sum of the two other dimers is never higher than 6%. In conclusion, isomeric dimers are produced through a dimerization in the inlet. No dimerization of isoprene occurs in the mass spectrometer source. Then care is needed when analyzing terpenic compounds in the presence of isoprene by GC-MS because structures, retention times and mass spectra of diprene and dipentene are close. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. A rapid and definitive diagnosis of kerosene dermatitis by an analysis of detached lesional epidermis using gas chromatography-mass spectrometry.

    PubMed

    Tsujino, Yoshio; Hieda, Yoko; Morita, Eishin

    2005-08-01

    A 73-year-old woman, who suffered from erythema with bullae and pustules on her abdomen and anterior right thigh, visited our hospital without an awareness of the causative agents. The lesions appeared like first and second degree burns. The small amount of detached roof of bulla was sampled without skin biopsy before the ointment treatment. The sample was sonicated in an ultrasonic bath for 1 min in n-pentane, and then 1 mul of the extract was analyzed by gas chromatography-mass spectrometry (GC-MS). The causative agent was determined to be kerosene. An examination of blood samples collected at the first visit failed to detect kerosene, though traces of trimethylbenzene were detected. A GC-MS analysis of the small sample of lesional epidermis was very useful to identify kerosene as a causative agent.

  1. A novel fast gas chromatography method for higher time resolution measurements of speciated monoterpenes in air

    NASA Astrophysics Data System (ADS)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2014-05-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in ambient air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C9-C15 BVOC composition of single plant emissions may be characterised within a 14.5 min analysis time. Moreover, in-situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an 11.7 min chromatographic separation time (increasing to 19.7 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). These analysis times potentially allow for a twofold to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in-situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC (OBVOC) linalool in ambient air. During this field deployment within a suburban forest

  2. Rapid screening and identification of illicit drugs by IR absorption spectroscopy and gas chromatography

    NASA Astrophysics Data System (ADS)

    Mengali, Sandro; Liberatore, Nicola; Luciani, Domenico; Viola, Roberto; Cardinali, Gian Carlo; Elmi, Ivan; Poggi, Antonella; Zampolli, Stefano; Biavardi, Elisa; Dalcanale, Enrico; Bonadio, Federica; Delemont, Olivier; Esseiva, Pierre; Romolo, Francesco S.

    2013-01-01

    Analytical instruments based on InfraRed Absorption Spectroscopy (IRAS) and Gas Chromatography (GC) are today available only as bench-top instrumentation for forensic labs and bulk analysis. Within the 'DIRAC' project funded by the European Commission, we are developing an advanced portable sensor, that combines miniaturized GC as its key chemical separation tool, and IRAS in a Hollow Fiber (HF) as its key analytical tool, to detect and recognize illicit drugs and key precursors, as bulk and as traces. The HF-IRAS module essentially consists of a broadly tunable External Cavity (EC) Quantum Cascade Laser (QCL), thermo-electrically cooled MCT detectors, and an infrared hollow fiber at controlled temperature. The hollow fiber works as a miniaturized gas cell, that can be connected to the output of the GC column with minimal dead volumes. Indeed, the module has been coupled to GC columns of different internal diameter and stationary phase, and with a Vapour Phase Pre-concentrator (VPC) that selectively traps target chemicals from the air. The presentation will report the results of tests made with amphetamines and precursors, as pure substances, mixtures, and solutions. It will show that the sensor is capable of analyzing all the chemicals of interest, with limits of detection ranging from a few nanograms to about 100-200 ng. Furthermore, it is suitable to deal with vapours directly trapped from the headspace of a vessel, and with salts treated in a basic solution. When coupled to FAST GC columns, the module can analyze multi-components mixes in less than 5 minutes.

  3. In situ analysis of martian regolith with the SAM experiment during the first mars year of the MSL mission: Identification of organic molecules by gas chromatography from laboratory measurements

    NASA Astrophysics Data System (ADS)

    Millan, M.; Szopa, C.; Buch, A.; Coll, P.; Glavin, D. P.; Freissinet, C.; Navarro-Gonzalez, R.; François, P.; Coscia, D.; Bonnet, J. Y.; Teinturier, S.; Cabane, M.; Mahaffy, P. R.

    2016-09-01

    The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

  4. In Situ Analysis of Martian Regolith with the SAM Experiment During the First Mars Year of the MSL Mission: Identification of Organic Molecules by Gas Chromatography from Laboratory Measurements

    NASA Technical Reports Server (NTRS)

    Millan, M.; Szopa, C.; Buch, A.; Coll, P.; Glavin, D. P.; Freissinet, C.; Navarro-Gonzalez, R.; Francois, P.; Coscia, D.; Bonnet, J. Y.; hide

    2016-01-01

    The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

  5. Analysis of chemical warfare agents by gas chromatography-mass spectrometry: methods for their direct detection and derivatization approaches for the analysis of their degradation products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valdez, Carlos A.; Leif, Roald N.; Hok, Saphon

    Abstract Chemical warfare agents (CWAs) are unarguably one of the most feared toxic substances produced by mankind. Their inception in conventional warfare can be traced as far back as the Middle Ages but their full breakthrough as central players in bellic conflicts was not realized until World War I. Since then, more modern CWAs along with efficient methods for their manufacture have emerged and violently shaped the way modern warfare and diplomatic relations are conducted. Owing to their mass destruction ability, counter methods to mitigate their impact appeared almost immediately on par with their development. These efforts have focused onmore » their efficient destruction, development of medical countermeasures and their detection by modern analytical chemistry methods. The following review seeks to provide the reader with a broad introduction on their direct detection by gas chromatography-mass spectrometry (GC-MS) and the various sample derivatization methods available for the analysis of their degradation products. The review concentrates on three of the main CWA classes and includes the nerve agents, the blistering agents and lastly, the incapacitating agents. Each section begins with a brief introduction of the CWA along with discussions of reports dealing with their detection in the intact form by GC-MS. Furthermore, as products arising from their degradation carry as much importance as the agents themselves in the field of forensic analysis, the available derivatization methods of these species are presented for each CWA highlighting some examples from our lab in the Forensic Science Center at the Lawrence Livermore National Laboratory.« less

  6. Analysis of chemical warfare agents by gas chromatography-mass spectrometry: methods for their direct detection and derivatization approaches for the analysis of their degradation products

    DOE PAGES

    Valdez, Carlos A.; Leif, Roald N.; Hok, Saphon; ...

    2017-07-25

    Abstract Chemical warfare agents (CWAs) are unarguably one of the most feared toxic substances produced by mankind. Their inception in conventional warfare can be traced as far back as the Middle Ages but their full breakthrough as central players in bellic conflicts was not realized until World War I. Since then, more modern CWAs along with efficient methods for their manufacture have emerged and violently shaped the way modern warfare and diplomatic relations are conducted. Owing to their mass destruction ability, counter methods to mitigate their impact appeared almost immediately on par with their development. These efforts have focused onmore » their efficient destruction, development of medical countermeasures and their detection by modern analytical chemistry methods. The following review seeks to provide the reader with a broad introduction on their direct detection by gas chromatography-mass spectrometry (GC-MS) and the various sample derivatization methods available for the analysis of their degradation products. The review concentrates on three of the main CWA classes and includes the nerve agents, the blistering agents and lastly, the incapacitating agents. Each section begins with a brief introduction of the CWA along with discussions of reports dealing with their detection in the intact form by GC-MS. Furthermore, as products arising from their degradation carry as much importance as the agents themselves in the field of forensic analysis, the available derivatization methods of these species are presented for each CWA highlighting some examples from our lab in the Forensic Science Center at the Lawrence Livermore National Laboratory.« less

  7. PCI-GC-MS-MS approach for identification of non-amino organic acid and amino acid profiles.

    PubMed

    Luan, Hemi; Yang, Lin; Ji, Fenfen; Cai, Zongwei

    2017-03-15

    Alkyl chloroformate have been wildly used for the fast derivatization of metabolites with amino and/or carboxyl groups, coupling of powerful separation and detection systems, such as GC-MS, which allows the comprehensive analysis of non-amino organic acids and amino acids. The reagents involving n-alkyl chloroformate and n-alcohol are generally employed for providing symmetric labeling terminal alkyl chain with the same length. Here, we developed an asymmetric labeling strategy and positive chemical ionization gas chromatography-tandem mass spectrometry (PCI-GC-MS-MS) approach for determination of non-amino organic acids and amino acids, as well as the short chain fatty acids. Carboxylic and amino groups could be selectively labelled by propyl and ethyl groups, respectively. The specific neutral loss of C 3 H 8 O (60Da), C 3 H 5 O 2 (74Da) and C 4 H 8 O 2 (88Da) were useful in the selective identification for qualitative analysis of organic acids and amino acid derivatives. PCI-GC-MS-MS using multiple reaction monitoring (MRM) was applied for semi-quantification of typical non-amino organic acids and amino acids. This method exhibited a wide range of linear range, good regression coefficient (R 2 ) and repeatability. The relative standard deviation (RSD) of targeted metabolites showed excellent intra- and inter-day precision (<5%). Our method provided a qualitative and semi-quantitative PCI-GC-MS-MS, coupled with alkyl chloroformate derivatization. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. A GC-MS-based metabolomics study on the tubers of commercial potato cultivars upon storage.

    PubMed

    Uri, Csilla; Juhász, Zsófia; Polgár, Zsolt; Bánfalvi, Zsófia

    2014-09-15

    Using gas chromatography-mass spectrometry (GC-MS) as a system for the detection of amino acids, organic acids, sugars, sugar alcohols, and fatty acids, we characterised six commercial potato cultivars (Hópehely, Katica, Lorett, Somogyi kifli, Vénusz Gold, and White Lady) with different pedigrees, starch contents, cooking types, and dormancy periods, in five developmental stages from harvest to sprouting. The tubers were stored at 20-22°C in the dark. The metabolite data were subjected to principal component analysis. No correlation between metabolite contents of freshly harvested tubers and starch content or cooking type of the cultivars was detected. The storage decreased the fructose and sucrose and increased the proline concentrations of tubers. Irrespective of the length of dormancy a substantial difference in metabolite composition at each time point upon storage was detected in each cultivar except Somogyi kifli, the only cultivar amongst those tested with a pure Solanum tuberosum origin and A cooking type. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Determination of iodopropynyl butylcarbamate in cosmetic formulations utilizing pulsed splitless injection, gas chromatography with electron capture detector.

    PubMed

    Palmer, Kevin B; LaFon, William; Burford, Mark D

    2017-09-22

    Current analytical methodology for iodopropynyl butylcarbamate (IPBC) analysis focuses on the use of liquid chromatography and mass spectrometer (LC-MS), but the high instrumentation and operator investment required has resulted in the need for a cost effective alternative methodology. Past publications investigating gas chromatography with electron capture detector (GC-ECD) for IPBC quantitation proved largely unsuccessful, likely due to the preservatives limited thermal stability. The use of pulsed injection techniques commonly used for trace analysis of thermally labile pharmaceutical compounds was successfully adapted for IPBC analysis and utilizes the selectivity of GC-ECD analysis. System optimization and sample preparation improvements resulted in substantial performance and reproducibility gains. Cosmetic formulations preserved with IPBC (50-100ppm) were solvated in toluene/isopropyl alcohol and quantified over the 0.3-1.3μg/ml calibration range. The methodology was robust (relative standard deviation 4%), accurate (98% recovery), and sensitive (limit of detection 0.25ng/ml) for use in routine testing of cosmetic formulation preservation. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Characterisation of odorants in roasted stem tea using gas chromatography-mass spectrometry and gas chromatography-olfactometry analysis.

    PubMed

    Sasaki, Tetsuya; Koshi, Erina; Take, Harumi; Michihata, Toshihide; Maruya, Masachika; Enomoto, Toshiki

    2017-04-01

    Roasted stem tea has a characteristic flavour, which is obtained by roasting tea stems, by-product of green tea production. This research aims to understand the characteristic odorants in roasted stem tea by comparing it to roasted leaf tea. We revealed potent odorants in commercial roasted stem tea using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-olfactometry with aroma extract dilution analysis (AEDA). The difference between roasted stem and leaf tea derived from the same tea plants were investigated using GC-MS. Pyrazine compounds exhibited a roasted odour and high flavour dilution (FD) factors, as determined via AEDA. Roasted stem tea was richer in these pyrazines than roasted leaf tea. Geraniol and linalool exhibited high FD factors and a floral odour, and roasted stem tea was richer in these compounds than roasted leaf tea. These results may have a positive impact on the development of tea products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Analysis of residual monomers in dendritic methacrylate copolymers and composites by HPLC and headspace-GC/MS.

    PubMed

    Viljanen, Eeva K; Langer, Sarka; Skrifvars, Mikael; Vallittu, Pekka K

    2006-09-01

    The aim of this study was to analyze the residual monomer content of photopolymerized dendritic methacrylate copolymers and particulate filler composites. Headspace-gas chromatography/mass spectrometry (HS-GC/MS) was compared with high performance liquid chromatography (HPLC). The resin mixtures consisted of a dendritic methacrylate monomer, methyl methacrylate and acetoacetoxyethyl methacrylate in varied proportions. In addition, one of the composites contained 1,4-butanediol dimethacrylate. Camphorquinone and 2-(N,N-dimethylamino)ethyl methacrylate were used as the light-activated initiator system. The content of residual methyl methacrylate and acetoacetoxyethyl methacrylate after 40 s photopolymerization were analyzed with HPLC and HS-GC/MS. The content of residual methyl methacrylate decreased and residual acetoacetoxyethyl methacrylate increased with increasing concentration of acetoacetoxyethyl methacrylate in the resin mixture. The results with both methods had the same trend. The addition of acetoacetoxyethyl methacrylate enhanced the copolymerization of methyl methacrylate, but did not decrease the total residual monomer content. The HS-GC/MS method was found to be a feasible method in the analysis of low-boiling residuals in dental polymers.

  12. Chemical ecology of obligate pollination mutualisms: testing the 'private channel' hypothesis in the Breynia-Epicephala association.

    PubMed

    Svensson, Glenn P; Okamoto, Tomoko; Kawakita, Atsushi; Goto, Ryutaro; Kato, Makoto

    2010-06-01

    *Obligate mutualisms involving actively pollinating seed predators are among the most remarkable insect-plant relationships known, yet almost nothing is known about the chemistry of pollinator attraction in these systems. The extreme species specificity observed in these mutualisms may be maintained by specific chemical compounds through 'private channels'. Here, we tested this hypothesis using the monoecious Breynia vitis-idaea and its host-specific Epicephala pollinator as a model. *Headspace samples were collected from both male and female flowers of the host. Gas chromatography with electroantennographic detection (GC-EAD), coupled gas chromatography-mass spectrometry, and olfactometer bioassays were used to identify the floral compounds acting as the pollinator attractant. *Male and female flowers of B. vitis-idaea produced similar sets of general floral compounds, but in different ratios, and male flowers emitted significantly more scent than female flowers. A mixture of 2-phenylethyl alcohol and 2-phenylacetonitrile, the two most abundant compounds in male flowers, was as attractive to female moths as the male flower sample, although the individual compounds were slightly less attractive when tested separately. *Data on the floral scent signals mediating obligate mutualisms involving active pollination are still very limited. We show that system-specific chemistry is not necessary for efficient host location by exclusive pollinators in these tightly coevolved mutualisms.

  13. Detection of Agar, by Analysis of Sugar Markers, Associated with Bacillus Anthracis Spores, After Culture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wunschel, David S.; Colburn, Heather A.; Fox, Alvin

    2008-08-01

    Detection of small quantities of agar associated with spores of Bacillus anthracis could provide key information regarding its source or growth characteristics. Agar, widely used in growth of bacteria on solid surfaces, consists primarily of repeating polysaccharide units of 3,6-anhydro-L-galactose (AGal) and galactose (Gal) with sulfated and O-methylated galactoses present as minor constituents. Two variants of the alditol acetate procedure were evaluated for detection of potential agar markers associated with spores. The first method employed a reductive hydrolysis step, to stabilize labile anhydrogalactose, by converting to anhydrogalactitol. The second eliminated the reductive hydrolysis step simplifying the procedure. Anhydrogalactitol, derived frommore » agar, was detected using both derivatization methods followed by gas chromatography-mass spectrometry (GC-MS) analysis. However, challenges with artefactual background (reductive hydrolysis) or marker destruction (hydrolysis) lead to the search for alternative sugar markers. A minor agar component, 6-O-methyl galactose (6-O-M gal), was readily detected in agar-grown but not broth-grown bacteria. Detection was optimized by the use of gas chromatography-tandem mass spectrometry (GC-MS-MS). With appropriate choice of sugar marker and analytical procedure, detection of sugar markers for agar has considerable potential in microbial forensics.« less

  14. Metabolism of androsta-1,4,6-triene-3,17-dione and detection by gas chromatography/mass spectrometry in doping control.

    PubMed

    Parr, Maria K; Fusshöller, Gregor; Schlörer, Nils; Opfermann, Georg; Piper, Thomas; Rodchenkov, Grigory; Schänzer, Wilhelm

    2009-01-01

    The urinary metabolism of the irreversible aromatase inhibitor androsta-1,4,6-triene-3,17-dione was investigated. It is mainly excreted unchanged and as its 17beta-hydroxy analogue. For confirmation, 17beta-hydroxyandrosta-1,4,6-trien-3-one was synthesized and characterized by nuclear magnetic resonance (NMR) in addition to the parent compound. In addition, several reduced metabolites were detected in the post-administration urines, namely 17beta-hydroxyandrosta-1,4-dien-3-one (boldenone), 17beta-hydroxy-5beta-androst-1-en-3-one (boldenone metabolite), 17beta-hydroxyandrosta-4,6-dien-3-one, and androsta-4,6-diene-3,17-dione. The identification was performed by comparison of the metabolites with reference material utilizing gas chromatography/mass spectrometry (GC/MS) of the underivatized compounds and GC/MS and GC/tandem mass spectrometry (MS/MS) of their trimethylsilyl (TMS) derivatives. Alterations in the steroid profile were also observed, most obviously in the androsterone/testosterone ratio. Even if not explicitly listed, androsta-1,4,6-triene-3,17-dione is classified as a prohibited substance in sports by the World Anti-Doping Agency (WADA) due to its aromatase-inhibiting properties. In 2006 three samples from human routine sports doping control tested positive for metabolites of androsta-1,4,6-triene-3,17-dione. The samples were initially found suspicious for the boldenone metabolite 17beta-hydroxy-5beta-androst-1-en-3-one. Since metabolites of androst-4-ene-3,6,17-trione were also present in the urine samples, it is presumed that these findings were due to the administration of a product like 'Novedex Xtreme', which could be easily obtained from the sport supplement market. Copyright (c) 2008 John Wiley & Sons, Ltd.

  15. Characterizing Vaccinium berry Standard Reference Materials by GC-MS using NIST spectral libraries.

    PubMed

    Lowenthal, Mark S; Andriamaharavo, Nirina R; Stein, Stephen E; Phinney, Karen W

    2013-05-01

    A gas chromatography-mass spectrometry (GC-MS)-based method was developed for qualitative characterization of metabolites found in Vaccinium fruit (berry) dietary supplement Standard Reference Materials (SRMs). Definitive identifications are provided for 98 unique metabolites determined among six Vaccinium-related SRMs. Metabolites were enriched using an organic liquid/liquid extraction, and derivatized prior to GC-MS analysis. Electron ionization (EI) fragmentation spectra were searched against EI spectra of authentic standards compiled in the National Institute of Standards and Technology's mass spectral libraries, as well as spectra selected from the literature. Metabolite identifications were further validated using a retention index match along with prior probabilities and were compared with results obtained in a previous effort using collision-induced dissociation (CID) MS/MS datasets from liquid chromatography coupled to mass spectrometry experiments. This manuscript describes a nontargeted metabolite profile of Vaccinium materials, compares results among related materials and from orthogonal experimental platforms, and discusses the feasibility and development of using mass spectral library matching for nontargeted metabolite identification.

  16. Multivariate Optimization for Extraction of Pyrethroids in Milk and Validation for GC-ECD and CG-MS/MS Analysis

    PubMed Central

    Zanchetti Meneghini, Leonardo; Rübensam, Gabriel; Claudino Bica, Vinicius; Ceccon, Amanda; Barreto, Fabiano; Flores Ferrão, Marco; Bergold, Ana Maria

    2014-01-01

    A simple and inexpensive method based on solvent extraction followed by low temperature clean-up was applied for determination of seven pyrethroids residues in bovine raw milk using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) and gas chromatography with electron-capture detector (GC-ECD). Sample extraction procedure was established through the evaluation of seven different extraction protocols, evaluated in terms of analyte recovery and cleanup efficiency. Sample preparation optimization was based on Doehlert design using fifteen runs with three different variables. Response surface methodologies and polynomial analysis were used to define the best extraction conditions. Method validation was carried out based on SANCO guide parameters and assessed by multivariate analysis. Method performance was considered satisfactory since mean recoveries were between 87% and 101% for three distinct concentrations. Accuracy and precision were lower than ±20%, and led to no significant differences (p < 0.05) between results obtained by GC-ECD and GC-MS/MS techniques. The method has been applied to routine analysis for determination of pyrethroid residues in bovine raw milk in the Brazilian National Residue Control Plan since 2013, in which a total of 50 samples were analyzed. PMID:25380457

  17. Simultaneous detection and quantitation of organic impurities in methamphetamine by ultra-high-performance liquid chromatography-tandem mass spectrometry, a complementary technique for methamphetamine profiling.

    PubMed

    Li, Li; Brown, Jaclyn L; Toske, Steven G

    2018-04-06

    The analysis of organic impurities plays an important role in the impurity profiling of methamphetamine, which in turn provides valuable information about methamphetamine manufacturing, in particular its synthetic route, chemicals, and precursors used. Ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) is ideally suited for this purpose due to its excellent sensitivity, selectivity, and wide linear range in multiple reaction monitoring (MRM) mode. In this study, a dilute-and-shoot UHPLC-MS/MS method was developed for the simultaneous identification and quantitation of 23 organic manufacturing impurities in illicit methamphetamine. The developed method was validated in terms of stability, limit of detection (LOD), lower limit of quantification (LLOQ), accuracy, and precision. More than 100 illicitly prepared methamphetamine samples were analyzed. Due to its ability to detect ephedrine/pseudoephedrine and its high sensitivity for critical target markers (eg, chloro-pseudoephedrine, N-cyclohexylamphetamine, and compounds B and P), more impurities and precursor/pre-precursors were identified and quantified versus the current procedure by gas chromatography-mass spectrometry (GC-MS). Consequently, more samples could be classified by their synthetic routes. However, the UHPLC-MS/MS method has difficulty in detecting neutral and untargeted emerging manufacturing impurities and can therefore only serve as a complement to the current method. Despite this deficiency, the quantitative information acquired by the presented UHPLC-MS/MS methodology increased the sample discrimination power, thereby enhancing the capacity of methamphetamine profiling program (MPP) to conduct sample-sample comparisons. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  18. Determination of endocrine disrupting chemicals and antiretroviral compounds in surface water: A disposable sorptive sampler with comprehensive gas chromatography - Time-of-flight mass spectrometry and large volume injection with ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wooding, Madelien; Rohwer, Egmont R; Naudé, Yvette

    2017-05-05

    Many rural dwellers and inhabitants of informal settlements in South Africa are without access to treated water and collect untreated water from rivers and dams for personal use. Endocrine disrupting chemicals (EDCs) have been detected in surface water and wildlife of South Africa. EDCs are often present in complex environmental matrices at ultra-trace levels complicating detection thereof. We report a simplified multi-residue approach for the detection and quantification of EDCs, emerging EDCs, and antiretroviral drugs in surface water. A low cost (less than one US dollar), disposable, sorptive extraction sampler was prepared in-house. The disposable samplers consisted of polydimethylsiloxane (PDMS) tubing fashioned into a loop which was then placed in water samples to concentrate EDCs and emerging pollutants. The PDMS samplers were thermally desorbed directly in the inlet of a GC, thereby eliminating the need for expensive consumable cryogenics. Comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for compound separation and identification. Linear retention indices of EDCs and emerging pollutants were determined on a proprietary Crossbond ® phase Rtx ® -CLPesticides II GC capillary column. In addition, large volume injection of surface water into an ultra-performance liquid chromatograph tandem mass spectrometer (UPLC-MS/MS) was used as complementary methodology for the detection of less volatile compounds. Large volume injection reduced tedious and costly sample preparation steps. Limits of detection for the GC method ranged from 1 to 98pg/l and for the LC method from 2 to 135ng/l. Known and emerging EDCs such as pharmaceuticals, personal care products and pesticides, as well as the antiretroviral compounds, efavirenz and nevirapine, were detected in surface water from South Africa at concentration levels ranging from 0.16ng/l to 227ng/l. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A facile one-pot preparation of Co3O4/g-C3N4 heterojunctions with excellent electrocatalytic activity for the detection of environmental phenolic hormones

    NASA Astrophysics Data System (ADS)

    Sun, Yanjuan; Jiang, Jizhou; Liu, Yi; Wu, Shengli; Zou, Jing

    2018-02-01

    The Co3O4/g-C3N4 heterojunctions were prepared by a facile one-pot thermal decomposition technique. Compared with g-C3N4, it was found that Co3O4/g-C3N4 heterojunctions possessed a higher Brunner-Emmet-Teller (BET) surface area, which was beneficial to the diffusion of aim molecules on the electrode surfaces. And the optimal Co3O4/g-C3N4 heterojunctions exhibited a narrower band gap and a higher donor density, resulting in an excellent electrocatalytic activity for environmental phenolic hormones. Moreover, the Co3O4/g-C3N4 heterojunctions were used for the electrochemical sensing of environmental phenolic hormones such as bisphenol A, pentachlorophenol, p-nitrophenol and octylphenol. All detection ranges reached three orders of magnitude, showing a lower limit of detection of 10-9 mol L-1. So, sensitivity and accurate determination of environmental phenolic hormones in real water samples may use this Co3O4/g-C3N4 heterojunctions modified electrode.

  20. N,N-Dimethyltryptamine and dichloromethane: rearrangement of quaternary ammonium salt product during GC-EI and CI-MS-MS analysis.

    PubMed

    Brandt, Simon D; Martins, Cláudia P B; Freeman, Sally; Dempster, Nicola; Wainwright, Mark; Riby, Philip G; Alder, John F

    2008-05-12

    N,N-Dimethyltryptamine (DMT) 1 is a simple tryptamine derivative with powerful psychoactive properties. It is abundant in nature and easily accessible through a variety of synthetic routes. Most work-up procedures require the use of organic solvents and halogenated representatives are often employed. DMT was found to be reactive towards dichloromethane, either during work-up or long term storage therein, which led to the formation of the quaternary ammonium salt N-chloromethyl-DMT chloride 2. Analysis of this side-product by gas chromatography ion trap mass spectrometry (GC-MS), both in electron and chemical ionisation tandem MS modes, gave only degradation products. For example, 2 could not be detected but appeared to have rearranged to 3-(2-chloroethyl)indole 3 and 2-methyltetrahydro-beta-carboline 4, whereas HPLC analysis enabled the detection of 2. GC-MS is a standard tool for the fingerprinting of drug products. The identification of a particular synthetic route is based on the analysis of impurities, provided these side products can be established to be route-specific. The in situ detection of both 3 and 4 within a DMT sample may have led to erroneous conclusions with regards to the identification of the synthetic route.

  1. Concurrent Lactic and Volatile Fatty Acid Analysis of Microbial Fermentation Samples by Gas Chromatography with Heat Pre-treatment.

    PubMed

    Darwin; WipaCharles; Cord-Ruwisch, Ralf

    2018-01-01

    Organic acid analysis of fermentation samples can be readily achieved by gas chromatography (GC), which detects volatile organic acids. However, lactic acid, a key fermentation acid is non-volatile and can hence not be quantified by regular GC analysis. However the addition of periodic acid to organic acid samples has been shown to enable lactic acid analysis by GC, as periodic acid oxidizes lactic acid to the volatile acetaldehyde. Direct GC injection of lactic acid standards and periodic acid generated inconsistent and irreproducible peaks, possibly due to incomplete lactic acid oxidation to acetaldehyde. The described method is developed to improve lactic acid analysis by GC by using a heat treated derivatization pre-treatment, such that it becomes independent of the retention time and temperature selection of the GC injector. Samples containing lactic acid were amended by periodic acid and heated in a sealed test tube at 100°C for at least 45 min before injecting it to the GC. Reproducible and consistent peaks of acetaldehyde were obtained. Simultaneous determination of lactic acid, acetone, ethanol, butanol, volatile fatty acids could also be accomplished by applying this GC method, enabling precise and convenient organic acid analysis of biological samples such as anaerobic digestion and fermentation processes. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. A novel Fast Gas Chromatography based technique for higher time resolution measurements of speciated monoterpenes in air

    NASA Astrophysics Data System (ADS)

    Jones, C. E.; Kato, S.; Nakashima, Y.; Kajii, Y.

    2013-12-01

    Biogenic emissions supply the largest fraction of non-methane volatile organic compounds (VOC) from the biosphere to the atmospheric boundary layer, and typically comprise a complex mixture of reactive terpenes. Due to this chemical complexity, achieving comprehensive measurements of biogenic VOC (BVOC) in air within a satisfactory time resolution is analytically challenging. To address this, we have developed a novel, fully automated Fast Gas Chromatography (Fast-GC) based technique to provide higher time resolution monitoring of monoterpenes (and selected other C9-C15 terpenes) during plant emission studies and in ambient air. To our knowledge, this is the first study to apply a Fast-GC based separation technique to achieve quantification of terpenes in air. Three chromatography methods have been developed for atmospheric terpene analysis under different sampling scenarios. Each method facilitates chromatographic separation of selected BVOC within a significantly reduced analysis time compared to conventional GC methods, whilst maintaining the ability to quantify individual monoterpene structural isomers. Using this approach, the C10-C15 BVOC composition of single plant emissions may be characterised within a ~ 14 min analysis time. Moreover, in situ quantification of 12 monoterpenes in unpolluted ambient air may be achieved within an ~ 11 min chromatographic separation time (increasing to ~ 19 min when simultaneous quantification of multiple oxygenated C9-C10 terpenoids is required, and/or when concentrations of anthropogenic VOC are significant). This corresponds to a two- to fivefold increase in measurement frequency compared to conventional GC methods. Here we outline the technical details and analytical capability of this chromatographic approach, and present the first in situ Fast-GC observations of 6 monoterpenes and the oxygenated BVOC linalool in ambient air. During this field deployment within a suburban forest ~ 30 km west of central Tokyo, Japan, the

  3. Fast Sampling Gas Chromatography (GC) System for Speciation in a Shock Tube

    DTIC Science & Technology

    2016-10-31

    capture similar ethylene decomposition rates for temperature-dependent shock experiments. (a) Papers published in peer-reviewed journals (N/A for none...3 GC Sampling System Validation Experiments ............................................................................... 5 Ethylene ...results for cold shock experiments, and both techniques capture similar ethylene decomposition rates for temperature-dependent shock experiments. Problem

  4. Protocols for the measurement of the F2-isoprostane, 15(S)-8-iso-prostaglandin F2α, in biological samples by GC-MS or GC-MS/MS coupled with immunoaffinity column chromatography.

    PubMed

    Tsikas, Dimitrios; Suchy, Maria-Theresia

    2016-04-15

    Arachidonic acid, the origin of the eicosanoids family, occurs in biological samples as free acid and as ester in lipids. Free arachidonic acid is oxidized to numerous metabolites by means of enzymes including cyclooxygenase (COX). Arachidonic acid esterified to lipids is attacked by reactive oxygen species (ROS) to generate numerous oxidized arachidonic acid derivatives. Generally, it is assumed that ROS-derived arachidonic acid derivatives are distinct from those generated by enzymes such as COX. Therefore, ROS-generated eicosanoids are considered specific biomarkers of oxidative stress. However, there are serious doubts concerning a strict distinction between the enzyme-derived eicosanoids and the ROS-derived iso-eicosanoids. Prominent examples are prostaglandin F2α (PGF2α) and 15(S)-8-iso-prostaglandin F2α (15(S)-8-iso-PGF2α) which have been originally considered to exclusively derive from COX and ROS, respectively. There is convincing evidence that both COX and ROS can oxidize arachidonic acid to PGF2α and 15(S)-8-iso-PGF2α. Thus, many results previously reported for 15(S)-8-iso-PGF2α as exclusive ROS-dependent reaction product, and consequently as a specific biomarker of oxidative stress, require a careful re-examination which should also consider the analytical methods used to measure 15(S)-8-iso-PGF2α. This prominent but certainly not the only example underlines more than ever the importance of the analytical chemistry in basic and clinical research areas of oxidative stress. In the present work, we report analytical protocols for the reliable quantitative determination of 15(S)-8-iso-PGF2α in human biological samples including plasma and urine by mass spectrometry coupled to gas chromatography (GC-MS, GC-MS/MS) after specific isolation of endogenous 15(S)-8-iso-PGF2α and the externally added internal standard [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α by immunoaffinity column chromatography (IAC). 15(S)-8-iso-PGF2α esterified to plasma lipids is

  5. Monoterpene separation by coupling proton transfer reaction time-of-flight mass spectrometry with fastGC.

    PubMed

    Materić, Dušan; Lanza, Matteo; Sulzer, Philipp; Herbig, Jens; Bruhn, Dan; Turner, Claire; Mason, Nigel; Gauci, Vincent

    2015-10-01

    Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection <1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O(+), such as NO(+) and O2 (+), have been introduced. However, monoterpenes, which belong to the most important plant VOCs, still cannot be distinguished so more traditional technologies, such as gas chromatography mass spectrometry (GC-MS), have to be utilised. GC-MS is very time consuming (up to 1 h) and cannot be used for real-time analysis. Here, we introduce a sensitive, near-to-real-time method for plant monoterpene research-PTR-MS coupled with fastGC. We successfully separated and identified six of the most abundant monoterpenes in plant studies (α- and β-pinenes, limonene, 3-carene, camphene and myrcene) in less than 80 s, using both standards and conifer branch enclosures (Norway spruce, Scots pine and black pine). Five monoterpenes usually present in Norway spruce samples with a high abundance were separated even when the compound concentrations were diluted to 20 ppbv. Thus, fastGC-PTR-ToF-MS was shown to be an adequate one-instrument solution for plant monoterpene research.

  6. Miniature GC-Minicell Ion Mobility Spectrometer (IMS) for In Situ Measurements in Astrobiology Planetary Missions

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Stimac, Robert M.; Kaye, William J.; Holland, Paul M.; Takeuchi, Norishige

    2006-01-01

    Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or ionger mission life for stationary landers/laboratories. The miniCometary Ice and Dust Experiment (miniCIDEX), which combined Gas Chromatography (GC) with helium Ion Mobility Spectrometry (IMS), was capable of providing the wide range of analytical information required for Astrobiology missions. The IMS used here was based on the PCP model 111 IMS. A similar system, the Titan Ice and Dust Experiment (TIDE), was proposed as part of the Titan Orbiter Aerorover Mission (TOAM). Newer GC systems employing Micro Electro- Mechanical System (MEMS) based technology have greatly reduced both the size and resource requirements for space GCs. These smaller GCs, as well as the continuing miniaturization of Astrobiology analytical instruments in general, has highlighted the need for smaller, dry helium IMS systems. We describe here the development of a miniature, MEMS GC-IMS system (MEMS GC developed by Thorleaf Research Inc.), employing the MiniCell Ion Mobility Spectrometer (IMS), from Ion Applications Inc., developed through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA s Small Business Innovative Research (SBIR) Program.

  7. Targeted analyte deconvolution and identification by four-way parallel factor analysis using three-dimensional gas chromatography with mass spectrometry data.

    PubMed

    Watson, Nathanial E; Prebihalo, Sarah E; Synovec, Robert E

    2017-08-29

    Comprehensive three-dimensional gas chromatography with time-of-flight mass spectrometry (GC 3 -TOFMS) creates an opportunity to explore a new paradigm in chemometric analysis. Using this newly described instrument and the well understood Parallel Factor Analysis (PARAFAC) model we present one option for utilization of the novel GC 3 -TOFMS data structure. We present a method which builds upon previous work in both GC 3 and targeted analysis using PARAFAC to simplify some of the implementation challenges previously discovered. Conceptualizing the GC 3 -TOFMS instead as a one-dimensional gas chromatograph with GC × GC-TOFMS detection we allow the instrument to create the PARAFAC target window natively. Each first dimension modulation thus creates a full GC × GC-TOFMS chromatogram fully amenable to PARAFAC. A simple mixture of 115 compounds and a diesel sample are interrogated through this methodology. All test analyte targets are successfully identified in both mixtures. In addition, mass spectral matching of the PARAFAC loadings to library spectra yielded results greater than 900 in 40 of 42 test analyte cases. Twenty-nine of these cases produced match values greater than 950. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Development of a Direct Headspace Collection Method from Arabidopsis Seedlings Using HS-SPME-GC-TOF-MS Analysis

    PubMed Central

    Kusano, Miyako; Iizuka, Yumiko; Kobayashi, Makoto; Fukushima, Atsushi; Saito, Kazuki

    2013-01-01

    Plants produce various volatile organic compounds (VOCs), which are thought to be a crucial factor in their interactions with harmful insects, plants and animals. Composition of VOCs may differ when plants are grown under different nutrient conditions, i.e., macronutrient-deficient conditions. However, in plants, relationships between macronutrient assimilation and VOC composition remain unclear. In order to identify the kinds of VOCs that can be emitted when plants are grown under various environmental conditions, we established a conventional method for VOC profiling in Arabidopsis thaliana (Arabidopsis) involving headspace-solid-phase microextraction-gas chromatography-time-of-flight-mass spectrometry (HS-SPME-GC-TOF-MS). We grew Arabidopsis seedlings in an HS vial to directly perform HS analysis. To maximize the analytical performance of VOCs, we optimized the extraction method and the analytical conditions of HP-SPME-GC-TOF-MS. Using the optimized method, we conducted VOC profiling of Arabidopsis seedlings, which were grown under two different nutrition conditions, nutrition-rich and nutrition-deficient conditions. The VOC profiles clearly showed a distinct pattern with respect to each condition. This study suggests that HS-SPME-GC-TOF-MS analysis has immense potential to detect changes in the levels of VOCs in not only Arabidopsis, but other plants grown under various environmental conditions. PMID:24957989

  9. More than 170 polyunsaturated tocopherol-related compounds in a vitamin E capsule: Countercurrent chromatographic enrichment, gas chromatography/mass spectrometry analysis and preliminary identification of the potential artefacts.

    PubMed

    Hammann, Simon; Kröpfl, Alexander; Vetter, Walter

    2016-12-09

    Tocopherols and tocotrienols (usually summed up as vitamin E) are a class of structurally related natural antioxidants. Commonly, only some of the eight classic representatives (four tocopherols and four tocotrienols) are found with varied composition in food. In this study we fractionated 230mg oil from commercial vitamin E supplement capsules by countercurrent chromatography (CCC) and subsequent analysis by gas chromatography with mass spectrometry (GC/MS) of silylated CCC fractions showed that these eight isomers represented only about 70% of total tocopherol compounds. Detailed analysis enabled the detection of 161T 3 isomers (α-, γ- and δ-T 3 ) along with 18 tetra- and several penta-unsaturated isomers (tocools), two tocomonoenol isomers, and several degradation products with shorter isoprenoid side chain (apo-tocools). Altogether, over 170 tocool compounds, most likely artefacts which originated from an inappropriate oil refining process were described in this study. Silver ion high performance liquid chromatography (Ag + -HPLC) was used to separate one fraction rich in γ-T 3 into four peaks each consisting of at least five peaks according to GC/MS. About ten γ-T 3 isomers were also detected in rice bran oils from one producer bought retail in Germany. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Determination of the alkylpyrazine composition of coffee using stable isotope dilution-gas chromatography-mass spectrometry (SIDA-GC-MS).

    PubMed

    Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke

    2013-07-03

    A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.

  11. [Study on supercritical CO2 extraction of xiaoyaosan and its GC-MS fingerprint].

    PubMed

    Zuo, Ya-Mei; Tian, Jun-Sheng; Guo, Xiao-Qing; Zhou, Yu-Zhi; Gao, Xiao-Xia; Qin, Xue-Mei

    2014-02-01

    To determine the optimum conditions of supercritical CO2 extraction of Xiaoyaosan, and establish its fingerprint by gas chromatography-mass spectrometry (GC-MS), the yield of extract were investigated, an orthogonal test was used to quantify the effects of extraction temperature, pressure, CO2 flow rate and time, and fingerprint analysis of different batches of extracts were by GC-MS. The optimal extraction conditions were determined as follows: extraction pressure 20 MPa, extraction temperature 50 degrees C, CO2 flow rate 25 kg x h(-1), extraction time 3 h, and average yield 2.2%. The GC-MS fingerprint was established and 27 common peaks were found, whose contents add up to 81.89% of the total peak area. Among them, 21 compounds were identified, accounting for 53.20% of the total extract. The extraction process is reasonable and favorable for industrial production. The GC-MS method is accurate, reliable, reproducible, and can be used for quality control of supercritical CO2 extract from Xiaoyaosan.

  12. Review of recent developments and applications in low-pressure (vacuum outlet) gas chromatography

    USDA-ARS?s Scientific Manuscript database

    The concept of low pressure (LP) vacuum outlet gas chromatography (GC) was introduced more than 50 years ago, but it was not until the 2000s that its theoretical applicability to fast analysis of GC-amenable chemicals was realized. In practice, LPGC is implemented by placing the outlet of a short, ...

  13. Flow-switching device for comprehensive two-dimensional gas chromatography.

    PubMed

    Bueno, Pedro A; Seeley, John V

    2004-02-20

    A simple flow-switching device has been developed as a differential flow modulator for comprehensive two-dimensional gas chromatography (GC x GC). The device is assembled from tubing, four tee unions, and a solenoid valve. The solenoid valve is located outside the oven of the gas chromatograph and is not in the sample path. The modulation technique has no inherent temperature restrictions and passes 100% of the primary column effluent to the secondary column(s). Secondary peaks are produced with widths at half maximum less than 100 ms when operating in GC x 2GC mode with a 2.0 s modulation period. The efficacy of this approach is demonstrated through the analysis of a standard mixture of volatile organic compounds (VOCs) and diesel fuel.

  14. Regional water-quality analysis of 2,4-D and dicamba in river water using gas chromatography-isotope dilution mass spectrometry

    USGS Publications Warehouse

    Thurman, E.M.; Zimmerman, L.R.; Aga, D.S.; Gilliom, R.J.

    2001-01-01

    Gas chromatography with isotope dilution mass spectrometry (GC-MS) and enzyme-linked immunosorbent assay (ELISA) were used in regional National Water Quality Assessment studies of the herbicides, 2,4-D and dicamba, in river water across the United States. The GC-MS method involved solid-phase extraction, derivatized with deutemted 2,4-D, and analysis by selected ion monitoring. The ELISA method was applied after preconcentration with solid-phase extraction. The ELISA method was unreliable because of interference from humic substances that were also isolated by solid-phase extraction. Therefore, GC-MS was used to analyzed 80 samples from river water from 14 basins. The frequency of detection of dicamba (28%) was higher than that for 2,4-D (16%). Concentrations were higher for dicamba than for 2,4-D, ranging from less than the detection limit (<0.05 ??g/L) to 3.77 ??g/L, in spite of 5 times more annual use of 2,4-D as compared to dicamba. These results suggest that 2,4-D degrades more rapidly in the environment than dicamba.

  15. Evaluation of three headspace sorptive extraction coatings for the determination of volatile terpenes in honey using gas chromatography-mass spectrometry.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2015-06-19

    Headspace sorptive extraction (HSSE) was used to preconcentrate seven monoterpenes (eucalyptol, linalool, menthol, geraniol, carvacrol, thymol and eugenol) for separation by gas chromatography and mass spectrometry (GC-MS). Three commercially available coatings for the stir bars, namely Polydimethylsiloxane (PDMS), polyacrilate (PA) and Ethylene glycol-silicone (EG-Silicone), were tested, and the influential parameters both in the adsorption and the thermal desorption steps were optimized. PDMS provided the best sensitivity for linalool, geraniol, menthol and eucalyptol, whereas EG-Silicone was best for extracting the phenolic monoterpenes studied. Considering the average obtained slopes from all compounds, PDMS pointed as the best option, and the analytical characteristics for the HSSE-TD-GC-MS method using this coating were obtained. Quantification of the samples was carried out by matrix-matched calibration using a synthetic honey. Detection limits ranged between 0.007 and 0.032 ng g(-1), depending on the compound. Twelve honey samples of different floral origins were analyzed using the HSSE-GC-MS method, the analytes being detected at concentrations up to 64 ng g(-1). Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Characterization of Chemical Composition of Pericarpium Citri Reticulatae Volatile Oil by Comprehensive Two-Dimensional Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry.

    PubMed

    Qin, Kunming; Zheng, Lijuan; Cai, Hao; Cao, Gang; Lou, Yajing; Lu, Tulin; Shu, Yachun; Zhou, Wei; Cai, Baochang

    2013-01-01

    Pericarpium Citri Reticulatae (Chenpi in Chinese) has been widely used as an herbal medicine in Korea, China, and Japan. Chenpi extracts are used to treat indigestion and inflammatory syndromes of the respiratory tract such as bronchitis and asthma. This thesis will analyze chemical compositions of Chenpi volatile oil, which was performed by comprehensive two-dimensional gas chromatography with high-resolution time-of-flight mass spectrometry (GC × GC-HR-TOFMS). One hundred and sixty-seven components were tentatively identified, and terpene compounds are the main components of Chenpi volatile oil, a significant larger number than in previous studies. The majority of the eluted compounds, which were identified, were well separated as a result of high-resolution capability of the GC × GC method, which significantly reduces, the coelution. β -Elemene is tentatively qualified by means of GC × GC in tandem with high-resolution TOFMS detection, which plays an important role in enhancing the effects of many anticancer drugs and in reducing the side effects of chemotherapy. This study suggests that GC × GC-HR-TOFMS is suitable for routine characterization of chemical composition of volatile oil in herbal medicines.

  17. GC and GC-MS characterization of crude oil transformation in sediments and microbial mat samples after the 1991 oil spill in the Saudi Arabian Gulf coast.

    PubMed

    Garcia de Oteyza, T; Grimalt, J O

    2006-02-01

    The massive oil discharge in the Saudi Arabian coast at the end of the 1991 Gulf War is used here as a natural experiment to study the ability of microbial mats to transform oil residues after major spills. The degree of oil transformation has been evaluated from the analysis of the aliphatic and aromatic hydrocarbons by gas chromatography (GC) and GC coupled to mass spectrometry (GC-MS). The oil-polluted microbial mat samples from coastal environments exhibited an intermediate degree of transformation between that observed in superficial and deep sediments. Evaporation, photo-oxidation and water-washing seemed to lead to more effective and rapid elimination of hydrocarbons than cyanobacteria and its associated microorganisms. Furthermore, comparison of some compounds (e.g. regular isoprenoid hydrocarbons or alkylnaphthalenes) in the oil collected in the area after the spill or in the mixtures retained by cyanobacterial growth gave rise to an apparent effect of hydrocarbon preservation in the microbial mat ecosystems.

  18. Impurity profiling of trinitrotoluene using vacuum-outlet gas chromatography-mass spectrometry.

    PubMed

    Brust, Hanneke; Willemse, Sander; Zeng, Tuoyu; van Asten, Arian; Koeberg, Mattijs; van der Heijden, Antoine; Bolck, Annabel; Schoenmakers, Peter

    2014-12-29

    In this work, a reliable and robust vacuum-outlet gas chromatography-mass spectrometry (GC-MS) method is introduced for the identification and quantification of impurities in trinitrotoluene (TNT). Vacuum-outlet GC-MS allows for short analysis times; the analysis of impurities in TNT was performed in 4min. This study shows that impurity profiling of TNT can be used to investigate relations between TNT samples encountered in forensic casework. A wide variety of TNT samples were analyzed with the developed method. Dinitrobenzene, dinitrotoluene, trinitrotoluene and amino-dinitrotoluene isomers were detected at very low levels (<1wt.%) by applying the MS in selected-ion monitoring (SIM) mode. Limits of detection ranged from 6ng/mL for 2,6-dinitrotoluene to 43ng/mL for 4-amino-2,6-dinitrotoluene. Major impurities in TNT were 2,4-dinitrotoluene and 2,3,4-trinitrotoluene. Impurity profiles based on seven compounds showed to be useful to TNT samples from different sources. Statistical analysis of these impurity profiles using likelihood ratios demonstrated the potential to investigate whether two questioned TNT samples encountered in forensic casework are from the same source. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Analysis of ammonium nitrate headspace by on-fiber solid phase microextraction derivatization with gas chromatography mass spectrometry.

    PubMed

    Lubrano, Adam L; Andrews, Benjamin; Hammond, Mark; Collins, Greg E; Rose-Pehrsson, Susan

    2016-01-15

    A novel analytical method has been developed for the quantitation of trace levels of ammonia in the headspace of ammonium nitrate (AN) using derivatized solid phase microextraction (SPME) fibers with gas chromatography mass spectrometry (GC-MS). Ammonia is difficult to detect via direct injection into a GC-MS because of its low molecular weight and extreme polarity. To circumvent this issue, ammonia was derivatized directly onto a SPME fiber by the reaction of butyl chloroformate coated fibers with the ammonia to form butyl carbamate. A derivatized externally sampled internal standard (dESIS) method based upon the reactivity of diethylamine with unreacted butyl chloroformate on the SPME fiber to form butyl diethylcarbamate was established for the reproducible quantification of ammonia concentration. Both of these compounds are easily detectable and separable via GC-MS. The optimized method was then used to quantitate the vapor concentration of ammonia in the headspace of two commonly used improvised explosive device (IED) materials, ammonium nitrate fuel oil (ANFO) and ammonium nitrate aluminum powder (Ammonal), as well as identify the presence of additional fuel components within the headspace. Published by Elsevier B.V.

  20. Processing of N-linked oligosaccharides from precursor- to mature-form herpes simplex virus type 1 glycoprotein gC.

    PubMed Central

    Serafini-Cessi, F; Dall'Olio, F; Pereira, L; Campadelli-Fiume, G

    1984-01-01

    Immature and mature forms of glycoprotein gC were purified by immunoadsorbent from herpes simplex virus type 1-infected BHK cells labeled with [3H]mannose for a 20-min pulse or for 11 h followed by a 3-h chase. The nature of N-asparagine-linked oligosaccharides carried by the immature form, pgC (molecular weight = 92,000), and the mature gC (molecular weight = 120,000) has been investigated. All pronase-digested glycopeptides of pgC were susceptible to endo-beta-N-acetylglucosaminidase H treatment; thus they have a high-mannose structure. Using thin-layer chromatography to separate endo-beta-N-acetylglucosaminidase H-cleaved oligosaccharides, polymannosyl chains of different sizes, ranging from Man9GlcNAc to Man5GlcNAc, were separated. The major components were Man8GlcNAc and Man7GlcNAc, suggesting that pgC labeled in a 20-min pulse represents the form of glycoprotein already routed to the Golgi apparatus. Analysis of glycopeptides of mature gC showed that the majority (95%) of N-linked glycans were converted to complex-type glycans. Ion-exchange chromatography and affinity chromatography on concanavalin A-Sepharose and leucoagglutinin-agarose revealed that diantennary and triantennary glycans predominated, whereas tetrantennary chains were not present. Parts of the di- and triantennary chains were not fully sialylated. The high heterogeneity of complex-type chains found in mature gC may be related to the high number of N-glycosylation sites of the glycoprotein as predicted by DNA sequencing studies (Frink et al., J. Virol. 45:634-647, 1983). Images PMID:6088806

  1. Processing of N-linked oligosaccharides from precursor- to mature-form herpes simplex virus type 1 glycoprotein gC.

    PubMed

    Serafini-Cessi, F; Dall'Olio, F; Pereira, L; Campadelli-Fiume, G

    1984-09-01

    Immature and mature forms of glycoprotein gC were purified by immunoadsorbent from herpes simplex virus type 1-infected BHK cells labeled with [3H]mannose for a 20-min pulse or for 11 h followed by a 3-h chase. The nature of N-asparagine-linked oligosaccharides carried by the immature form, pgC (molecular weight = 92,000), and the mature gC (molecular weight = 120,000) has been investigated. All pronase-digested glycopeptides of pgC were susceptible to endo-beta-N-acetylglucosaminidase H treatment; thus they have a high-mannose structure. Using thin-layer chromatography to separate endo-beta-N-acetylglucosaminidase H-cleaved oligosaccharides, polymannosyl chains of different sizes, ranging from Man9GlcNAc to Man5GlcNAc, were separated. The major components were Man8GlcNAc and Man7GlcNAc, suggesting that pgC labeled in a 20-min pulse represents the form of glycoprotein already routed to the Golgi apparatus. Analysis of glycopeptides of mature gC showed that the majority (95%) of N-linked glycans were converted to complex-type glycans. Ion-exchange chromatography and affinity chromatography on concanavalin A-Sepharose and leucoagglutinin-agarose revealed that diantennary and triantennary glycans predominated, whereas tetrantennary chains were not present. Parts of the di- and triantennary chains were not fully sialylated. The high heterogeneity of complex-type chains found in mature gC may be related to the high number of N-glycosylation sites of the glycoprotein as predicted by DNA sequencing studies (Frink et al., J. Virol. 45:634-647, 1983).

  2. Detection of Synthetic Testosterone Use by Novel Comprehensive Two-Dimensional Gas Chromatography Combustion Isotope Ratio Mass Spectrometry (GC×GCC-IRMS)

    PubMed Central

    Tobias, Herbert J.; Zhang, Ying; Auchus, Richard J.; Brenna, J. Thomas

    2011-01-01

    We report the first demonstration of Comprehensive Two-dimensional Gas Chromatography Combustion Isotope Ratio Mass Spectrometry (GC×GCC-IRMS) for the analysis of urinary steroids to detect illicit synthetic testosterone use, of interest in sport doping. GC coupled to IRMS (GCC-IRMS) is currently used to measure the carbon isotope ratios (CIR, δ13C) of urinary steroids in anti-doping efforts; however, extensive cleanup of urine extracts is required prior to analysis to enable baseline separation of target steroids. With its greater separation capabilities, GC×GC has the potential to reduce sample preparation requirements and enable CIR analysis of minimally processed urine extracts. Challenges addressed include on-line reactors with minimized dimensions to retain narrow peaks shapes, baseline separation of peaks in some cases, and reconstruction of isotopic information from sliced steroid chromatographic peaks. Difficulties remaining include long-term robustness of on-line reactors and urine matrix effects that preclude baseline separation and isotopic analysis of low concentration and trace components. In this work, steroids were extracted, acetylated, and analyzed using a refined, home-built GC×GCC-IRMS system. 11-hydroxy-androsterone (11OHA) and 11-ketoetiocolanolone (11KE) were chosen as endogenous reference compounds (ERC) because of their satisfactory signal intensity, and their CIR was compared to target compounds (TC) androsterone (A) and etiocholanolone (E). Separately, a GC×GC-qMS system was used to measure testosterone (T)/EpiT concentration ratios. Urinary extracts of urine pooled from professional athletes, and urine from one individual that received testosterone gel (T-gel) and one individual that received testosterone injections (T-shot) were analyzed. The average precisions of δ13C and Δδ13C measurements were SD(δ13C) approximately ± 1‰ (n=11). The T-shot sample resulted in a positive for T use with a T/EpiT ratio of > 9 and CIR

  3. Chemical Analysis of the Chinese Liquor Luzhoulaojiao by Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Yao, Feng; Yi, Bin; Shen, Caihong; Tao, Fei; Liu, Yumin; Lin, Zhixin; Xu, Ping

    2015-04-01

    Luzhoulaojiao liquor is a type of Chinese liquor that dates back hundreds of years, but whose precise chemical composition remains unknown. This paper describes the screening of the liquor and the identification of its compounds using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOF-MS). Samples were prepared by both liquid-liquid extraction and solid-phase microextraction, which facilitated the detection of thousands of compounds in the liquor, thus demonstrating the superior performance of the proposed method over those reported in previous studies. A total of 320 compounds were common to all 18 types of Luzhoulaojiao liquor studied here, and 13 abundant and potentially bioactive compounds were further quantified. The results indicated that the high-performance method presented here is well suited for the detection and identification of compounds in liquors. This study also contributes to enriching our knowledge of the contents of Chinese liquors.

  4. Enhanced Isotopic Ratio Outlier Analysis (IROA) Peak Detection and Identification with Ultra-High Resolution GC-Orbitrap/MS: Potential Application for Investigation of Model Organism Metabolomes.

    PubMed

    Qiu, Yunping; Moir, Robyn D; Willis, Ian M; Seethapathy, Suresh; Biniakewitz, Robert C; Kurland, Irwin J

    2018-01-18

    Identifying non-annotated peaks may have a significant impact on the understanding of biological systems. In silico methodologies have focused on ESI LC/MS/MS for identifying non-annotated MS peaks. In this study, we employed in silico methodology to develop an Isotopic Ratio Outlier Analysis (IROA) workflow using enhanced mass spectrometric data acquired with the ultra-high resolution GC-Orbitrap/MS to determine the identity of non-annotated metabolites. The higher resolution of the GC-Orbitrap/MS, together with its wide dynamic range, resulted in more IROA peak pairs detected, and increased reliability of chemical formulae generation (CFG). IROA uses two different 13 C-enriched carbon sources (randomized 95% 12 C and 95% 13 C) to produce mirror image isotopologue pairs, whose mass difference reveals the carbon chain length (n), which aids in the identification of endogenous metabolites. Accurate m/z, n, and derivatization information are obtained from our GC/MS workflow for unknown metabolite identification, and aids in silico methodologies for identifying isomeric and non-annotated metabolites. We were able to mine more mass spectral information using the same Saccharomyces cerevisiae growth protocol (Qiu et al. Anal. Chem 2016) with the ultra-high resolution GC-Orbitrap/MS, using 10% ammonia in methane as the CI reagent gas. We identified 244 IROA peaks pairs, which significantly increased IROA detection capability compared with our previous report (126 IROA peak pairs using a GC-TOF/MS machine). For 55 selected metabolites identified from matched IROA CI and EI spectra, using the GC-Orbitrap/MS vs. GC-TOF/MS, the average mass deviation for GC-Orbitrap/MS was 1.48 ppm, however, the average mass deviation was 32.2 ppm for the GC-TOF/MS machine. In summary, the higher resolution and wider dynamic range of the GC-Orbitrap/MS enabled more accurate CFG, and the coupling of accurate mass GC/MS IROA methodology with in silico fragmentation has great potential in

  5. Detection and characterization of a new metabolite of 17alpha-methyltestosterone.

    PubMed

    Pozo, Oscar J; Van Eenoo, Peter; Deventer, Koen; Lootens, Leen; Van Thuyne, Wim; Parr, Maria K; Schänzer, Wilhelm; Sancho, Juan V; Hernández, Felix; Meuleman, Philip; Leroux-Roels, Geert; Delbeke, Frans T

    2009-11-01

    The misuse of the anabolic steroid methyltestosterone is currently routinely monitored in doping control laboratories by gas chromatography-mass spectrometry (GC-MS) of two of its metabolites: 17alpha-methyl-5beta-androstane-3alpha,17beta-diol and 17alpha-methyl-5alpha-androstane-3alpha,17beta-diol. Because of the absence of any easy ionizable moiety, these metabolites are poorly detectable using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). In this study, the metabolism of methyltestosterone has been reinvestigated by the use of a precursor ion scan method in LC-ESI-MS/MS. Two metabolites have been detected using this method. Both compounds have been confirmed in postadministration urine samples of an urokinase plasminogen activator-severe combined immunodeficiency (uPA-SCID) mouse with humanized liver and were characterized by LC-MS/MS and GC-MS using both quadrupole and time of flight analyzers. From the detailed study of the fragmentation, these metabolites were proposed to be epimethyltestosterone and a dehydrogenated compound. Epimethyltestosterone has previously been described as a minor metabolite, whereas the occurrence of the oxidized metabolite has not been reported. Comparison with the synthesized reference revealed that the structure of the dehydrogenated metabolite is 6-ene-epimethyltestosterone. A selected reaction monitoring method including three transitions for each metabolite has been developed and applied to samples from an excretion study and to samples declared positive after GC-MS analysis. 6-Ene-epimethyltestosterone was found in all samples, showing its applicability in the detection of methyltestosterone misuse.

  6. Identification of multi-insecticide residues using GC-NPD and the degradation kinetics of chlorpyrifos in sweet corn and soils.

    PubMed

    Wang, Peidan; Rashid, Muhammad; Liu, Jie; Hu, Meiying; Zhong, Guohua

    2016-12-01

    Because more than one insecticide is applied to crops to protect plants from pests, an analytical multi-residue determination method was developed using gas chromatography with a nitrogen phosphorus detector (GC-NPD). The retention time for 12 insecticides was 3.7-27.7min. Under the selected conditions, the limits of detection (LOD) and quantification (LOQ) were below the maximum residue limits (MRLs) and in the range of 0.00315-0.05μgmL(-1) and 0.01-0.165μgmL(-1), respectively. Using GC-NPD, we investigated the dissipation dynamics and final residual levels of chlorpyrifos in sweet corn and soil and determined that the half-lives was 4-7days, that is, that chlorpyrifos is safe to use on sweet corn with a pre-harvest interval of 16-22days before harvest. These results provide new insights into chlorpyrifos degradation in plants and its environmental behavior. Copyright © 2016. Published by Elsevier Ltd.

  7. Identification of tamoxifen and metabolites in human male urine by GC/MS.

    PubMed

    Mihailescu, R; Aboul-Enein, H Y; Efstatide, M D

    2000-05-01

    Tamoxifen is an antiestrogenic drug which is used in the treatment of breast cancer and nonmalignant breast disorders. It also has a stimulating effect on the secretion of hypofisar gonadotropic hormones and is generally used in the treatment of infertility. In males, tamoxifen causes an increase of endogenous production of androgenic steroids, and therefore is used by athletes. A method for identification of tamoxifen and metabolites in urine, using the gas chromatography and mass spectrometry system (GC/MS) is described. This study also reports the extraction methodology of tamoxifen and metabolites in urine samples of healthy male volunteers and the GC/MS conditions used to identify tamoxifen and its metabolites.

  8. Development, validation and application of a SDME/GC-FID methodology for the multiresidue determination of organophosphate and pyrethroid pesticides in water.

    PubMed

    Pinheiro, Anselmo de Souza; de Andrade, Jailson B

    2009-10-15

    A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus and pyrethroid pesticides in water by gas chromatography (GC) with flame ionization detection (GC-FID). The significant parameters that affect SDME performance, such as the selection of microextraction solvent, solvent volume, extraction time, and stirring rate, were studied and optimized using a tool screening factorial design. The limits of detection (LODs) in water for the four investigated compounds were between 0.3 and 3.0 microgL(-1), with relative standard deviations ranging from 7.7 to 18.8%. Linear response data were obtained in the concentration range of 0.9-6.0 microg L(-1) (lambda-cyhalothrin), 3.0-60.0 microg L(-1) (methyl parathion), 9.0-60.0 microg L(-1) (ethion), and 9.0-30.0 microg L(-1) (permethrin), with correlation coefficients ranging from 0.9337 to 0.9977. The relative recoveries for the spiked water ranged from 73.0 to 104%. Environmental water samples (n=26) were successfully analyzed using the proposed method and methyl parathion presented concentration up to 2.74 microg L(-1). The SDME method, coupled with GC-FID analysis, provided good precision, accuracy, and reproducibility over a wide linear range. Other highlights of the method include its ease of use and its requirement of only small volumes of both organic solvent and sample.

  9. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Hok, S; Alcaraz, A

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less

  10. Development of a GC-APCI-QTOFMS library for new psychoactive substances and comparison to a commercial ESI library.

    PubMed

    Mesihää, Samuel; Ketola, Raimo A; Pelander, Anna; Rasanen, Ilpo; Ojanperä, Ilkka

    2017-03-01

    Gas chromatography coupled to atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (GC-APCI-QTOFMS) was evaluated for the identification of new psychoactive substances (NPS). An in-house high mass resolution GC-APCI-QTOFMS test library was developed for 29 nitrogen-containing drugs belonging mostly to synthetic stimulants. The library was based on 12 intra-day measurements of each compound at three different collision energies, 10, 20 and 40 eV. The in-house library mass spectra were compared to mass spectra from a commercial library constructed by liquid chromatography-electrospray ionization (LC-ESI) QTOFMS. The reversed library search scores between the in-house GC-APCI library and the commercial LC-ESI library were compared once a week during a 5-week period by using data measured by GC-APCI-QTOFMS. The protonated molecule was found for all drugs in the full scan mode, and the drugs were successfully identified by both libraries in the targeted MS/MS mode. The GC-APCI library score averaged over all collision energies was as high as 94.4/100 with a high repeatability, while the LC-ESI library score was also high (89.7/100) with a repeatability only slightly worse. These results highlight the merits of GC-APCI-QTOFMS in the analysis of NPS even in situations where the reference standards are not immediately available, taking advantage of the accurate mass measurement of the protonated molecule and product ions, and comparison to existing soft-ionization mass spectral libraries. Graphical abstract Tandem mass spectra obtained from GC-APCI-QTOFMS are comparable to LC-ESI-QTOFMS library spectra.

  11. Sample collection and preparation of biofluids and extracts for gas chromatography-mass spectrometry.

    PubMed

    Emwas, Abdul-Hamid M; Al-Talla, Zeyad A; Kharbatia, Najeh M

    2015-01-01

    To maximize the utility of gas chromatography-mass spectrometry (GC-MS) in metabonomics research, all stages of the experimental design should be standardized, including sample collection, storage, preparation, and sample separation. Moreover, the prerequisite for any GC-MS analysis is that a compound must be volatile and thermally stable if it is to be analyzed using this technique. Since many metabolites are nonvolatile and polar in nature, they are not readily amenable to analysis by GC-MS and require initial chemical derivatization of the polar functional groups in order to reduce the polarity and to increase the thermal stability and volatility of the analytes. In this chapter, an overview is presented of the optimum approach to sample collection, storage, and preparation for gas chromatography-mass spectrometry-based metabonomics with particular focus on urine samples as example of biofluids.

  12. The detection of dissolved gases in transformer oil by gas chromatography with helium ionization detector

    NASA Astrophysics Data System (ADS)

    Deng, Xian-qin; Fang, Hua; Li, Min-xian

    2017-07-01

    The GC-PDD with the technology of valve cutting and helium ionization detector was used to analyze the dissolved gases in ultra-high voltage(UHV) and extra-high voltage(EHV) transformer oil. The detection limit(DL) reached ppb grade, especially for the featuring gas—C2H2 and H2, whose DL could reach 5ppb and 11ppb respectively. The test reproducibility of the instrument was about 1% and the correlation coefficient of standard curve-r is greater or equal to 0.99, which showed obvious advantage compared with normal GC. In addition, the auxiliary gas of H2 was not used in this instrument, which completely improved the safety performance. Thus, the application of GC-PDD has significant meaning in warning potential malfunction inside the ultra-high voltage transformer in advance.

  13. Determination of 17 kinds of banned organochlorine pesticides in water by activated carbon fiber-solid phase microextraction coupled with GC-MS.

    PubMed

    Sun, Tonghua; Jia, Jinping; Zhong, Dengjie; Wang, Yalin

    2006-02-01

    Activated carbon fiber (ACF) as extraction fiber for solid-phase microextraction (SPME) and its application for the analysis of banned organochlorine pesticides (OCPs) were investigated. Firstly, ACF was activated by different concentration of zinc chloride, which indicated that ACF activated by 60% zinc chloride had a reasonable specific surface area, pore volume and pore distribution. Secondly, the parameters for the ACF-SPME procedure, the adsorption and desorption conditions, were also optimized when coupled with gas chromatography-mass spectrometry (GC-MS). Thirdly, the ACF-SPME was used to analyze 17 kinds of OCPs in water. The linearity of most pesticides was found to be between 0.2 and 50 microg/l with GC-MS under the selected ion monitoring (SIM) acquisition mode. The limits of detection (LOD) at the sub microg/l were obtained. The work demonstrated here shows that ACF is a promising alternative for the SPME procedure.

  14. Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection.

    PubMed

    Wang, Jun-Xia; Jiang, Dong-Qing; Gu, Zhi-Yuan; Yan, Xiu-Ping

    2006-12-22

    Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).

  15. Inter-comparison of laser photoacoustic spectroscopy and gas chromatography techniques for measurements of ethene in the atmosphere.

    PubMed

    Kuster, William C; Harren, Frans J M; de Gouw, Joost A

    2005-06-15

    Laser photoacoustic spectroscopy (LPAS) is highly suitable for the detection of ethene in air due to the overlap between its strongest absorption lines and the wavelengths accessible by high-powered CO2 lasers. Here, we test the ability of LPAS to measure ethene in ambient air by comparing the measurements in urban air with those from a gas chromatography flame-ionization detection (GC-FID) instrument. Over the course of several days, we obtained quantitative agreement between the two measurements. Over this period, the LPAS instrument had a positive offset of 330 +/- 140 pptv (parts-per-trillion by volume) relative to the GC-FID instrument, possibly caused by interference from other species. The detection limit of the LPAS instrument is currently estimated around 1 ppbv and is limited by this offset and the statistical noise in the data. We conclude that LPAS has the potential to provide fast-response measurements of ethene in the atmosphere, with significant advantages over existing techniques when measuring from moving platforms and in the vicinity of emission sources.

  16. Identification of refined petroleum products in contaminated soils using an identification index for GC chromatograms.

    PubMed

    Kwon, Dongwook; Ko, Myoung-Soo; Yang, Jung-Seok; Kwon, Man Jae; Lee, Seung-Woo; Lee, Seunghak

    2015-08-01

    Hydrocarbons found in the environment are typically characterized by gas chromatography (GC). The shape of the GC chromatogram has been used to identify the source of petroleum contamination. However, the conventional practice of simply comparing the peak patterns of source products to those of environmental samples is dependent on the subjective decisions of individual analysts. We have developed and verified a quantitative analytical method for interpreting GC chromatograms to distinguish refined petroleum products in contaminated soils. We found that chromatograms for gasoline, kerosene, and diesel could be divided into three ranges with boundaries at C6, C8, C16, and C26. In addition, the relative peak area (RPA(GC)) of each range, a dimensionless ratio of the peak area within each range to that of the total range (C6-C26), had a unique value for each petroleum product. An identification index for GC chromatograms (ID(GC)), defined as the ratio of RPA(GC) of C8-C16 to that of C16-C26, was able to identify diesel and kerosene sources in samples extracted from artificially contaminated soils even after weathering. Thus, the ID(GC) can be used to effectively distinguish between refined petroleum products in contaminated soils.

  17. Validation of an analytical method for nitrous oxide (N2O) laughing gas by headspace gas chromatography coupled to mass spectrometry (HS-GC-MS): forensic application to a lethal intoxication.

    PubMed

    Giuliani, N; Beyer, J; Augsburger, M; Varlet, V

    2015-03-01

    Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Supersonic molecular beam-hyperthermal surface ionisation coupled with time-of-flight mass spectrometry applied to trace level detection of polynuclear aromatic hydrocarbons in drinking water for reduced sample preparation and analysis time.

    PubMed

    Davis, S C; Makarov, A A; Hughes, J D

    1999-01-01

    Analysis of sub-ppb levels of polynuclear aromatic hydrocarbons (PAHs) in drinking water by high performance liquid chromatography (HPLC) fluorescence detection typically requires large water samples and lengthy extraction procedures. The detection itself, although selective, does not give compound identity confirmation. Benchtop gas chromatography/mass spectrometry (GC/MS) systems operating in the more sensitive selected ion monitoring (SIM) acquisition mode discard spectral information and, when operating in scanning mode, are less sensitive and scan too slowly. The selectivity of hyperthermal surface ionisation (HSI), the high column flow rate capacity of the supersonic molecular beam (SMB) GC/MS interface, and the high acquisition rate of time-of-flight (TOF) mass analysis, are combined here to facilitate a rapid, specific and sensitive technique for the analysis of trace levels of PAHs in water. This work reports the advantages gained by using the GC/HSI-TOF system over the HPLC fluorescence method, and discusses in some detail the nature of the instrumentation used.

  19. Evaluation of automated sample preparation, retention time locked gas chromatography-mass spectrometry and data analysis methods for the metabolomic study of Arabidopsis species.

    PubMed

    Gu, Qun; David, Frank; Lynen, Frédéric; Rumpel, Klaus; Dugardeyn, Jasper; Van Der Straeten, Dominique; Xu, Guowang; Sandra, Pat

    2011-05-27

    In this paper, automated sample preparation, retention time locked gas chromatography-mass spectrometry (GC-MS) and data analysis methods for the metabolomics study were evaluated. A miniaturized and automated derivatisation method using sequential oximation and silylation was applied to a polar extract of 4 types (2 types×2 ages) of Arabidopsis thaliana, a popular model organism often used in plant sciences and genetics. Automation of the derivatisation process offers excellent repeatability, and the time between sample preparation and analysis was short and constant, reducing artifact formation. Retention time locked (RTL) gas chromatography-mass spectrometry was used, resulting in reproducible retention times and GC-MS profiles. Two approaches were used for data analysis. XCMS followed by principal component analysis (approach 1) and AMDIS deconvolution combined with a commercially available program (Mass Profiler Professional) followed by principal component analysis (approach 2) were compared. Several features that were up- or down-regulated in the different types were detected. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Effective and sensitive determination of eleven disinfection byproducts in drinking water by DLLME and GC-MS.

    PubMed

    On, Jiwon; Pyo, Heesoo; Myung, Seung-Woon

    2018-10-15

    The aim of this study was to optimize the dispersive liquid-liquid microextraction (DLLME) parameters for simultaneous analysis through DLLME-gas chromatography-mass spectrometry (GC-MS) of six iodo-trihalomethanes, four haloacetonitriles, and one halonitromethane, which are residual disinfection products found in drinking water. Eleven disinfection by-product (DBPs) remaining in aqueous samples were extracted and concentrated using a simple, rapid, and environmentally friendly DLLME method, and then analyzed simultaneously by GC-MS. The optimized DLLME parameters were a sample volume of 5 mL, 100 μL of dichloromethane as the extraction solvent, 1 mL of methanol as the dispersion solvent, an extraction time of 60 s, and 1.5 g of sodium chloride for the salting out effect. The enrichment factor values obtained using the established DLLME-GC-MS method were 19.8-141.5, and the limit of detection and limit of quantification were 0.22-1.19 μg/L and 0.75-3.98 μg/L, respectively. The calibration curves had correlation coefficients (r 2 ) of 0.9958-0.9992 in the concentration range of 0.5-40 μg/L, and they exhibited good linearity in quantitative analysis. This new method could be useful for analyzing eleven DBPs that remain in drinking water. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Headspace Gas Chromatography Method for Studies of Reaction and Permeation of Volatile Agents with Solid Materials

    DTIC Science & Technology

    2015-01-01

    HEADSPACE GAS CHROMATOGRAPHY METHOD FOR STUDIES OF REACTION AND PERMEATION OF...TITLE AND SUBTITLE Headspace Gas Chromatography Method for Studies of Reaction and Permeation of Volatile Agents with Solid Materials 5a...method is described for measuring the reactivity and permeability of fabrics, films, and other solid materials. Headspace gas chromatography (GC)

  2. Identification of sulphur volatiles and GC-olfactometry aroma profiling in two fresh tomato cultivars

    USDA-ARS?s Scientific Manuscript database

    Ten sulphur volatiles were observed in two Florida tomato cultivars (‘Tasti-Lee’ and ‘FL 47’) harvested at three maturity stages (breaker, turning, and pink) using gas chromatography with a pulsed flame photometric detector (GC-PFPD). Eight PFPD peaks were identified using retention values from auth...

  3. Multi-residue method for the determination of 450 pesticide residues in honey, fruit juice and wine by double-cartridge solid-phase extraction/gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry.

    PubMed

    Pang, G-F; Fan, C-L; Liu, Y-M; Cao, Y-Z; Zhang, J-J; Fu, B-L; Li, X-M; Li, Z-Y; Wu, Y-P

    2006-08-01

    A multi-residue method was developed for the determination of 450 pesticide residues in honey, fruit juice and wine using double-cartridge solid-phase extraction (SPE), gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS). The method development was based on an appraisal of the characteristics of GC-MS and LC-MS-MS for 654 pesticides as well as the efficiency of extraction and purification from honey, fruit juice and wine. Samples were first diluted with water plus acetone, then extracted with portions of dichloromethane. The extracts were concentrated and cleaned up with graphitized carbon black and aminopropyl cartridges stacked in tandem. Pesticides were eluted with acetonitrile + toluene, and the eluates were concentrated. For 383 pesticides, the eluate was extracted with hexane twice and internal standard solution was added prior to GC-MS determination. For 67 pesticides, extraction was with methanol prior to LC-MS-MS determination. The limit of detection for the method was between 1.0 and 300 ng g(-1) depending on each pesticide analyte. At the three fortification levels of 2.0-3000 ng g(-1), the average recovery rates were between 59 and 123%, among which 413 pesticides (92% of the 450) had recovery rates of 70-120% and 35 pesticides (8% of the 450) had recovery rates of 59-70%. There were 437 pesticides (97% of the 450) with a relative standard deviation below 25%; there were 13 varieties (3% of the 450) between 25.0 and 30.4%.

  4. Microwave heating causes rapid degradation of antioxidants in polypropylene packaging, leading to greatly increased specific migration to food simulants as shown by ESI-MS and GC-MS.

    PubMed

    Alin, Jonas; Hakkarainen, Minna

    2011-05-25

    Microwave heating of commercial microwavable polypropylene packaging in contact with fatty food simulants caused significant antioxidant degradation and increased specific migration as shown by electrospray ionization-mass spectrometry (ESI-MS) and gas chromatography-mass spectrometry (GC-MS). Degradation of the antioxidants Irgafos 168 and Irganox 1010 was not detected during conventional heating of polypropylene packaging at the same temperature. The migration into aqueous food simulants was primarily restricted by the water solubility of the migrants. Using isooctane as fatty food simulant caused significant swelling and greatly enhanced overall migration values compared to the other fatty food simulant, 99.9% ethanol, or the aqueous food simulants 10% ethanol, 3% acetic acid, or water. ESI-MS spectra clearly reflected the overall migration values, and the number and amount of compounds detected decreased as the hydrophilicity of the food simulant increased. ESI-MS was shown to be an excellent tool for the analysis of semivolatile migrants and a good complement to GC-MS analysis of volatile migrants.

  5. GC-O, volatile and qualitative differences in locally grown rabbiteye and southern highbush blueberries, and juices

    USDA-ARS?s Scientific Manuscript database

    Southern and southeastern US production of blueberries has increased markedly in recent years. Gas chromatography-olfactometry (GC-O) and volatile and semi-volatile compounds are seldom reported in rabbiteye blueberry (RAB). Few comparisons have been made between the organoleptic differences betwe...

  6. Determination of nandrolone metabolites in human urine: comparison between liquid chromatography/tandem mass spectrometry and gas chromatography/mass spectrometry.

    PubMed

    Buiarelli, Francesca; Giannetti, Luigi; Jasionowska, Renata; Cruciani, Claudia; Neri, Bruno

    2010-07-15

    Nandrolone (19-nortestosterone) is an androgenic anabolic steroid illegally used as a growth-promoting agent in animal breeding and as a performance enhancer in athletics. Therefore, its use was officially banned in 1974 by the Medical Commission of the International Olympic Committee (IOC). Following nandrolone administration, the main metabolites in humans are 19-norandrosterone, 19-norethiocolanolone and 19-norepiandrosterone, and their presence in urine is the basis of detecting its abuse. The present work was undertaken to determine, in human urine, nandrolone metabolites (phase I and phase II) by developing and comparing multiresidue liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) methods. A double extraction by solid-phase extraction (SPE) was necessary for the complete elimination of the interfering compounds. The proposed methods were also tested on a real positive sample, and they allow us to determine the conjugated/free fractions ratio reducing the risk of false positive or misleading results and they should allow laboratories involved in doping control analysis to monitor the illegal use of steroids. The advantages of LC/MS/MS over GC/MS (which is the technique mainly used) include the elimination of the hydrolysis and derivatization steps: it is known that during enzymatic hydrolysis several steroids can be converted into related compounds and deconjugation is not always 100% effective. The validation parameters for the two methods were similar (limit of quantification (LOQ) <1 ng/mL and percentage coefficient of variance (CV%) <16.4), and both were able to confirm unambiguously all the analytes, thus confirming the validity of both techniques. Copyright 2010 John Wiley & Sons, Ltd.

  7. A reversed-phase compatible thin-layer chromatography autography for the detection of acetylcholinesterase inhibitors.

    PubMed

    Ramallo, I Ayelen; García, Paula; Furlan, Ricardo L E

    2015-11-01

    A dual readout autographic assay to detect acetylcholinesterase inhibitors present in complex matrices adsorbed on reversed-phase or normal-phase thin-layer chromatography plates is described. Enzyme gel entrapment with an amphiphilic copolymer was used for assay development. The effects of substrate and enzyme concentrations, pH, incubation time, and incubation temperature on the sensitivity and the detection limit of the assay were evaluated. Experimental design and response surface methodology were used to optimize conditions with a minimum number of experiments. The assay allowed the detection of 0.01% w/w of physostigmine in both a spiked Sonchus oleraceus L. extract chromatographed on normal phase and a spiked Pimenta racemosa (Mill.) J.W. Moore leaf essential oil chromatographed on reversed phase. Finally, the reversed-phase thin-layer chromatography assay was applied to reveal the presence of an inhibitor in the Cymbopogon citratus (DC.) Stapf essential oil. The developed assay is able to detect acetylcholinesterase inhibitors present in complex matrixes that were chromatographed in normal phase or reversed-phase thin-layer chromatography. The detection limit for physostigmine on both normal and reversed phase was of 1×10(-4) μg. The results can be read by a change in color and/or a change in fluorescence. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. [Determination of fatty acids in natural cream and artificial cream by comprehensive two-dimensional gas chromatography-mass spectrometry].

    PubMed

    Zhou, Ruize; Zhou, Ya; Mao, Ting; Jiang, Jie

    2018-01-08

    A method for the determination of 37 fatty acids in natural cream and artificial cream was developed by comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS). The samples were extracted with toluene and acetyl chloride-methanol (1:9,v/v) solution was added to the extract for fat esterification. Finally, the fatty acids were analyzed by GC×GC-MS. The GC conditions were as follows:a DB-5 column (30 m×0.25 mm×0.25 μm) was set as the 1st dimensional column and a BPX-50 column (2.5 m×0.1 mm×0.25 μm) was the 2nd dimensional column. The primary oven temperature was programmed from 50℃ (held for 2 min) to 180℃ at a rate of 20℃/min, followed by an increase to 250℃ at 2.5℃/min, then raised up to 300℃ (held for 5 min) at 3℃/min. The ion source temperature was 200℃ with auxiliary temperature of 300℃ in scan mode. All fatty acids were separated effectively and determined accurately while the modulation period was 5s and the scan range of MS was m/z 40-385. This procedure was applied to analyze the fatty acids in commercial natural cream and artificial cream from Chinese markets, among which we found the characteristic components in different kinds of samples. Compared with gas chromatography-flame ionization detector (GC-FID), GC×GC-MS method was more sensitive and more components of fatty acids were detected. Conclusively, this work suggests a new technical approach in analyzing fatty acids in natural cream and artificial cream, which is meaningful to ensure the quality identification and safety of natural cream.

  9. Analysis of alkyl phosphates in petroleum samples by comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection and post-column Deans switching.

    PubMed

    Nizio, Katie D; Harynuk, James J

    2012-08-24

    Alkyl phosphate based gellants used as viscosity builders for fracturing fluids used in the process of hydraulic fracturing have been implicated in numerous refinery-fouling incidents in North America. In response, industry developed an inductively coupled plasma optical emission spectroscopy (ICP-OES) based method for the analysis of total volatile phosphorus in distillate fractions of crude oil; however, this method is plagued by poor precision and a high limit of detection (0.5±1μg phosphorus mL(-1)). Furthermore this method cannot provide speciation information, which is critical for developing an understanding of the challenge of alkyl phosphates at a molecular level. An approach using comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection (GC×GC-NPD) and post-column Deans switching is presented. This method provides qualitative and quantitative profiles of alkyl phosphates in industrial petroleum samples with increased precision and at levels comparable to or below those achievable by ICP-OES. A recovery study in a fracturing fluid sample and a profiling study of alkyl phosphates in four recovered fracturing fluid/crude oil mixtures (flowback) are also presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Flight Validation of the Thermal Propellant Gauging Method used at EADS Astrium

    NASA Astrophysics Data System (ADS)

    Dandaleix, L.; Ounougha, L.; Jallade, S.

    2004-10-01

    EADS Astrium recently met a major milestone in the field of propellant gauging with the first reorbitation of an Eurostar tanks equipped satellite. It proved successful determining the remaining available propellant mass for spacecraft displacement beyond the customer specified graveyard orbit; thus demonstrating its expertness in Propellant Gauging in correlation with tank residual mass minimization. A critical parameter in satellite operational planning is indeed the accurate knowledge of the on-board remaining propellant mass; basically for the commercial telecommunication missions, where it is the major criterion for lifetime maximization. To provide an accurate and reliable process for measurement of this propellant mass throughout lifetime, EADS Astrium uses a Combination of two independent techniques: The Dead Reckoning Method (maximum accuracy at BOL), based on thrusters flow rate prediction &the Thermal Propellant Gauging Technique, deriving the propellant mass from the tank thermal capacity (Absolute gauging method, with increasing accuracy along lifetime). Then, the present article shows the recent flight validation of the Gauging method obtained for Eurostar E2000 propellant tanks including the validation of the different thermodynamic models. ABBREVIATIONS &ACRONYMS BOL, MOL, EOL: Beginning, Middle &End of Life Cempty: Empty tank thermal inertia [J/K] Chelium: Helium thermal inertia [J/K] Cpropellant: Propellant thermal inertia [J/K] Ct = C1+C2: Total tank thermal inertia (Subscript for upper node and for lower node) [J/K] CPS: Combined Propulsion System DR: Dead Reckoning FM: Flight Model LAE: Liquid Apogee Engine lsb: Least significant byte M0: TPGS Uncertainty component linked to Cempty mox, mfuel: Propellant mass of oxidiser &fuel [kg] Pox, Pfuel: Pressure of oxidiser &fuel [bar] PTA: Propellant Tank Assembly Q: Heater power [W] Qox, Qfuel: Mass flow rate of oxidiser &fuel [kg/s] RCT: Reaction Control Thrusters T0: Spacecraft platform equilibrium

  11. SAM Gcms Chromatography Performed at Mars : Elements of Interpretation

    NASA Astrophysics Data System (ADS)

    Szopa, C.; Coll, P. J.; Buch, A.; François, P.; Cabane, M.; Coscia, D.; Teinturier, S.; Navarro-Gonzalez, R.; Glavin, D. P.; Freissinet, C.; Mahaffy, P. R.

    2013-12-01

    The characterisation of the chemical and mineralogical composition of regolith samples collected with the Curiosity rover is a primary objective of the SAM experiment. These data should provide essential clues on the past habitability of Gale crater. Interpretation of the data collected after SAM pyrolysis evolved gas analysis (EGA) and gas chromatography mass spectrometry (GC-MS) experiments on the first soil samples collected by MSL at the Rocknest Aeolian Deposit in Gale Crater has been challenging due to the concomitant presence in the ovens of an oxychlorine phase present in the samples, and a derivatization agent coming from the SAM wet chemistry experiment (Glavin et al., 2013). Moreover, accurate identification and quantification, in the SAM EGA mode, of volatiles released from the heated sample, or generated by reactions occurring in the SAM pyrolysis oven, is also difficult for a few compounds due to evolution over similar temperature ranges and overlap of their MS signatures. Hence, the GC analyses, coupled with MS, enabled the separation and identification and quantification of most of the volatile compounds detected. These results can have been obtained through tests and calibration done with GC individual spare components and with the SAM testbed. This paper will present a view of the interpretation of the chromatograms obtained when analyzing the Rocknest and John Klein solid samples delivered to SAM, on sols 96 and 199 respectively, supported by laboratory calibrations.

  12. Using comprehensive two-dimensional gas chromatography to explore the geochemistry of the Santa Barbara oil seeps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reddy, Christopher; Nelson, Robert

    The development of comprehensive two-dimensional gas chromatography (GC x GC) has expanded the analytical window for studying complex mixtures like oil. Compared to traditional gas chromatography, this technology separates and resolves at least an order of magnitude more compounds, has a much larger signal to noise ratio, and sorts compounds based on their chemical class; hence, providing highly refined inventories of petroleum hydrocarbons in geochemical samples that was previously unattainable. In addition to the increased resolution afforded by GC x GC, the resulting chromatograms have been used to estimate the liquid vapor pressures, aqueous solubilities, octanol-water partition coefficients, and vaporizationmore » enthalpies of petroleum hydrocarbons. With these relationships, powerful and incisive analyses of phase-transfer processes affecting petroleum hydrocarbon mixtures in the environment are available. For example, GC x GC retention data has been used to quantitatively deconvolve the effects of phase transfer processes such as water washing and evaporation. In short, the positive attributes of GC x GC-analysis have led to a methodology that has revolutionized the analysis of petroleum hydrocarbons. Overall, this research has opened numerous fields of study on the biogeochemical "genetics" (referred to as petroleomics) of petroleum samples in both subsurface and surface environments. Furthermore, these new findings have already been applied to the behavior of oil at other seeps as well, for petroleum exploration and oil spill studies.« less

  13. Trace analysis in the food and beverage industry by capillary gas chromatography: system performance and maintenance.

    PubMed

    Hayes, M A

    1988-04-01

    Gas chromatography (GC) is the most widely used analytical technique in the food and beverage industry. This paper addresses the problems of sample preparation and system maintenance to ensure the most sensitive, durable, and efficient results for trace analysis by GC in this industry.

  14. Analysis of polycyclic aromatic hydrocarbons in water and beverages using membrane-assisted solvent extraction in combination with large volume injection-gas chromatography-mass spectrometric detection.

    PubMed

    Rodil, Rosario; Schellin, Manuela; Popp, Peter

    2007-09-07

    Membrane-assisted solvent extraction (MASE) in combination with large volume injection-gas chromatography-mass spectrometry (LVI-GC-MS) was applied for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. The MASE conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of extraction conditions (shaking speed, extraction temperature and time), extraction solvent and composition (ionic strength, sample pH and presence of organic solvent). Parameters like linearity and reproducibility of the procedure were determined. The extraction efficiency was above 65% for all the analytes and the relative standard deviation (RSD) for five consecutive extractions ranged from 6 to 18%. At optimized conditions detection limits at the ng/L level were achieved. The effectiveness of the method was tested by analyzing real samples, such as river water, apple juice, red wine and milk.

  15. Metabolism of the new psychoactive substances N,N-diallyltryptamine (DALT) and 5-methoxy-DALT and their detectability in urine by GC-MS, LC-MSn, and LC-HR-MS-MS.

    PubMed

    Michely, Julian A; Helfer, Andreas G; Brandt, Simon D; Meyer, Markus R; Maurer, Hans H

    2015-10-01

    N,N-Diallyltryptamine (DALT) and 5-methoxy-DALT (5-MeO-DALT) are synthetic tryptamine derivatives commonly referred to as so-called new psychoactive substances (NPS). They have psychoactive effects that may be similar to those of other tryptamine derivatives. The objectives of this work were to study the metabolic fate and detectability, in urine, of DALT and 5-MeO-DALT. For metabolism studies, rat urine obtained after high-dose administration was prepared by precipitation and analyzed by liquid chromatography-high-resolution mass spectrometry (LC-HR-MS-MS). On the basis of the metabolites identified, several aromatic and aliphatic hydroxylations, N-dealkylation, N-oxidation, and combinations thereof are proposed as the main metabolic pathways for both compounds. O-Demethylation of 5-MeO-DALT was also observed, in addition to extensive glucuronidation or sulfation of both compounds after phase I transformation. The cytochrome P450 (CYP) isoenzymes predominantly involved in DALT metabolism were CYP2C19, CYP2D6, and CYP3A4; those mainly involved in 5-MeO-DALT metabolism were CYP1A2, CYP2C19, CYP2D6, and CYP3A4. For detectability studies, rat urine was screened by GC-MS, LC-MS(n), and LC-HR-MS-MS after administration of low doses. LC-MS(n) and LC-HR-MS-MS were deemed suitable for monitoring consumption of both compounds. The most abundant targets were a ring hydroxy metabolite of DALT, the N,O-bis-dealkyl metabolite of 5-MeO-DALT, and their glucuronides. GC-MS enabled screening of DALT by use of its main metabolites only.

  16. Update of on-line coupled liquid chromatography - gas chromatography for the analysis of mineral oil hydrocarbons in foods and cosmetics.

    PubMed

    Biedermann, Maurus; Munoz, Celine; Grob, Koni

    2017-10-27

    On-line coupled high performance liquid chromatography-gas chromatography-flame ionization detection (HPLC-GC-FID) is the most widely used method for the analysis of mineral oil hydrocarbons in food, food contact materials, tissues and cosmetics. With comprehensive two-dimensional gas chromatography (GCxGC), a tool became available for better establishing the elution sequence of the various types of hydrocarbons from the HPLC column used for isolating the mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH). The performance of a heavily used HPLC column with reduced retention for MOAH was investigated to improve the robustness of the method. Updates are recommended that render the MOSH/MOAH separation less dependent of the state of the HPLC column and more correct in cases of highly refined mineral oil products of high molecular mass. Cyclohexyl cyclohexane (Cycy), used as internal standard, turned out to be eluted slightly after cholestane (Cho); apparently the size exclusion effect predominates the extra retention by ring number on the 60Å pore size silica gel. Hence, Cycy can be used to determine the end of the MOSH fraction. Long chain alkyl benzenes were eluted earlier than tri-tert. butyl benzene (Tbb). It is proposed to start the MOAH transfer immediately after the MOSH fraction and use a gradient causing breakthrough of dichloromethane (visible in the UV chromatogram) at a time suitable to elute perylene (Per) at the end of the fraction. In this way, a decrease in retention power of the HPLC column can be tolerated without adjustment of the MOAH fraction until some MOAH start being eluted into the MOSH fraction. This critical point can be checked either with di(2-ethylhexyl) benzene (DEHB) as a marker or the HPLC-UV chromatogram. Finally, based on new findings in rats and human tissues, it is recommended to integrate the MOSH and MOAH up to the retention time of the n-alkane C40. Copyright © 2017 Elsevier B.V. All rights

  17. Chemical Analysis of the Chinese Liquor Luzhoulaojiao by Comprehensive Two-Dimensional Gas Chromatography/Time-of-Flight Mass Spectrometry

    PubMed Central

    Yao, Feng; Yi, Bin; Shen, Caihong; Tao, Fei; Liu, Yumin; Lin, Zhixin; Xu, Ping

    2015-01-01

    Luzhoulaojiao liquor is a type of Chinese liquor that dates back hundreds of years, but whose precise chemical composition remains unknown. This paper describes the screening of the liquor and the identification of its compounds using comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GC × GC/TOF-MS). Samples were prepared by both liquid-liquid extraction and solid-phase microextraction, which facilitated the detection of thousands of compounds in the liquor, thus demonstrating the superior performance of the proposed method over those reported in previous studies. A total of 320 compounds were common to all 18 types of Luzhoulaojiao liquor studied here, and 13 abundant and potentially bioactive compounds were further quantified. The results indicated that the high-performance method presented here is well suited for the detection and identification of compounds in liquors. This study also contributes to enriching our knowledge of the contents of Chinese liquors. PMID:25857434

  18. Single-run determination of polybrominated diphenyl ethers (PBDEs) di- to deca-brominated in fish meal, fish oil and fish feed by isotope dilution: application of automated sample purification and gas chromatography/ion trap tandem mass spectrometry (GC/ITMS).

    PubMed

    Blanco, Sonia Lucía; Vieites, Juan M

    2010-07-05

    The present paper describes the application of automated cleanup and fractionation procedures of the Power Prep system (Fluid Management Systems) for the determination of polybrominated diphenyl ethers (PBDEs) in feeding stuffs and fish meal and oil. Gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITMS) allowed the analysis of di- to deca-BDEs in the samples matrices used in fish aquaculture. The method developed enabled the determination of 26 native PBDE congeners and 11 (13)C(12)-labelled congeners, including deca-BDE 209, in a single-run analysis, using isotope dilution. The automated cleanup, consisting of a succession of multilayer silica and basic alumina columns previously applied by Wyrzykowska et al. (2009) [28] in combustion flue gas, was successfully applied in our complex matrices. The method allowed an increase in productivity, i.e. lower time was required to process samples, and simultaneous purification of several samples was achieved at a time, reducing analyst dedication and human error input. Average recoveries of 43-96% were obtained. GC/ITMS can overcome the complexity originating from the sample matrix, eliminating matrix effects by tandem MS, to enable the detection of congeners penta- to nona-BDEs where interferent masses were present. The provisional detection limits, estimated in the samples, were 5-30 pg for di-, tri-, tetra-, and penta-BDEs, 20-65 pg for hexa-, hepta-, octa- and nona-BDEs, and 105 pg for deca-BDE. Reduction of deca-BDE 209 blank values is of concern to ongoing research. Good accuracy was obtained by application of the whole procedure, representing an efficient, low-cost and fast alternative for routine analyses. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Pyrolysis-gas chromatography-mass spectrometry for studying N-vinyl-2-pyrrolidone-co-vinyl acetate copolymers and their dissolution behaviour.

    PubMed

    Chojnacka, Aleksandra; Ghaffar, Abdul; Feilden, Andrew; Treacher, Kevin; Janssen, Hans-Gerd; Schoenmakers, Peter

    2011-11-14

    Knowledge on the solubility behaviour and dissolution rate of speciality and commodity polymers is very important for the use of such materials in high-tech applications. We have developed methods for the quantification and characterization of dissolved copolymers of N-vinyl-2-pyrrolidone (VP) and vinyl acetate (VA) during dissolution in water. The methods are based on pyrolysis (Py) performed in a programmed-temperature vaporization injector with subsequent identification and quantification of the components in the pyrolysate using capillary gas chromatography-mass spectrometry (GC-MS). By injecting large volumes and applying cryo-focussing at the top of the column, low detection limits could be achieved. The monomer ratio was found to have the greatest effect on the dissolution rate of the PVP-co-VA copolymers. The material with the highest amount of VA (50%) dissolves significantly slower than the other grades. Size-exclusion chromatography (SEC) and Py-GC-MS were used to measure molecular weights and average chemical compositions, respectively. Combined off-line SEC//Py-GC-MS was used to determine the copolymer composition (VP/VA ratio), as a function of the molecular weight for the pure polymers. In the dissolution experiments, a constant VP/VA ratio across the dissolution curve was observed for all copolymers analysed. This suggests a random distribution of the two monomers over the molecules. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. 40 CFR Appendix A to Subpart C of... - Alternative Testing Methods Approved for Analyses Under the Safe Drinking Water Act

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00. Heptachlor... Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post-column...