Sample records for chrome plating workers

  1. Study of skin and mucous membrane disorders among workers engaged in the sodium dichromate manufacturing industry and chrome plating industry.

    PubMed

    Singhal, Vijay Kumar; Deswal, Balbir Singh; Singh, Bachu Narayan

    2015-01-01

    Inhalation of dusts and fumes arising during the manufacture of sodium dichromate from chrome ore, chromic acid mist emitted during electroplating, and skin contact with chromate produce hazards to workers. (1) To elucidate the prevalence of skin and mucous membrane disorders among the workers engaged in the sodium dichromate manufacturing industry and chrome plating industry. (2) To know the relationship of prevalence with the duration of exposure to chrome mist, dust, and fumes. A cross-sectional study was conducted among all the workers engaged in sodium dichromate manufacturing and chrome plating from several industries situated near the Delhi-Haryana border in the districts of Faridabad and Sonepat of Haryana, India from January 01, 2014 to December 31, 2014. All the workers available from the concerned industries for the study were interviewed and medically examined after obtaining their informed consent. A total of 130 workers comprising 66 workers from the sodium dichromate manufacturing industry and 64 workers from the chrome plating industry were examined on a pretested schedule. Descriptive statistical methods (proportions, relative risk, and Chi-square test of significance with P value analyzed using Epi Info version 7). All the workers were found to be males and of the adult age group. Out of the total examined, 69.69% and 56.22% of the workers had disorders of the nasal mucous membrane in the sodium dichromate manufacturing industry and the chrome plating industry, respectively. 42.42% and 28.22% of the workers had perforation of the nasal septum in the sodium dichromate manufacturing industry and chrome plating industry, respectively. 6.06% and 3.12% workers had skin ulcers in the sodium dichromate manufacturing industry and chrome plating industry, respectively. Nasal irritation and rhinorrhea were the most commonly found symptoms in both the processes. 48.48% and 90.52% of the workers were using hand gloves in the sodium dichromate manufacturing and chrome plating industry, respectively. Only 27.27% and 37.50% of the workers were using masks in the sodium dichromate manufacturing industry and chrome plating industry, respectively. No worker was using protective clothing or barrier cream in the sodium dichromate manufacturing industry. 40.65% and 12.50% workers were using protective clothing and barrier cream in the chrome plating industry. Workers engaged in sodium dichromate manufacturing and chrome plating are at a great risk of skin and mucous membrane disorders including chrome holes and nasal septum perforation. Protective measures and awareness of the management and workers about the exposure hazards and safeguarding against them will be useful public measures to prevent these occupational hazards among workers engaged in these processes.

  2. Study of skin and mucous membrane disorders among workers engaged in the sodium dichromate manufacturing industry and chrome plating industry

    PubMed Central

    Singhal, Vijay Kumar; Deswal, Balbir Singh; Singh, Bachu Narayan

    2015-01-01

    Background: Inhalation of dusts and fumes arising during the manufacture of sodium dichromate from chrome ore, chromic acid mist emitted during electroplating, and skin contact with chromate produce hazards to workers. Objectives: (1) To elucidate the prevalence of skin and mucous membrane disorders among the workers engaged in the sodium dichromate manufacturing industry and chrome plating industry. (2) To know the relationship of prevalence with the duration of exposure to chrome mist, dust, and fumes. Settings and Design: A cross-sectional study was conducted among all the workers engaged in sodium dichromate manufacturing and chrome plating from several industries situated near the Delhi-Haryana border in the districts of Faridabad and Sonepat of Haryana, India from January 01, 2014 to December 31, 2014. Materials and Methods: All the workers available from the concerned industries for the study were interviewed and medically examined after obtaining their informed consent. A total of 130 workers comprising 66 workers from the sodium dichromate manufacturing industry and 64 workers from the chrome plating industry were examined on a pretested schedule. Statistical Analysis: Descriptive statistical methods (proportions, relative risk, and Chi-square test of significance with P value analyzed using Epi Info version 7). Results: All the workers were found to be males and of the adult age group. Out of the total examined, 69.69% and 56.22% of the workers had disorders of the nasal mucous membrane in the sodium dichromate manufacturing industry and the chrome plating industry, respectively. 42.42% and 28.22% of the workers had perforation of the nasal septum in the sodium dichromate manufacturing industry and chrome plating industry, respectively. 6.06% and 3.12% workers had skin ulcers in the sodium dichromate manufacturing industry and chrome plating industry, respectively. Nasal irritation and rhinorrhea were the most commonly found symptoms in both the processes. 48.48% and 90.52% of the workers were using hand gloves in the sodium dichromate manufacturing and chrome plating industry, respectively. Only 27.27% and 37.50% of the workers were using masks in the sodium dichromate manufacturing industry and chrome plating industry, respectively. No worker was using protective clothing or barrier cream in the sodium dichromate manufacturing industry. 40.65% and 12.50% workers were using protective clothing and barrier cream in the chrome plating industry. Conclusion: Workers engaged in sodium dichromate manufacturing and chrome plating are at a great risk of skin and mucous membrane disorders including chrome holes and nasal septum perforation. Protective measures and awareness of the management and workers about the exposure hazards and safeguarding against them will be useful public measures to prevent these occupational hazards among workers engaged in these processes. PMID:26957809

  3. Elevated Frequencies of Micronuclei and other Nuclear Abnormalities of Chrome Plating Workers Occupationally Exposed to Hexavalent Chromium.

    PubMed

    Sudha, S; Kripa, S K; Shibily, P; Shyn, J

    2011-01-01

    Biomonitoring provides a useful tool to estimate the genetic risk from exposure to genotoxic agents. The aim of this study was to assess the potential cytogenetic damage associated with occupational exposure to hexavalent chromium by using micronuclei (MN) as a biomarker. This was a cross-sectional study and all participants were males. Both the exposed and control individuals were selected from Coimbatore, Southern India. Exfoliated buccal cells from 44 chrome plating workers and 40 age and sex matched control subjects were examined for MN frequency and nuclear abnormalities (NA) other than micronuclei, such as binucleates, broken eggs, karyorrhexis, karyolysis and pyknosis. Results showed statistically significant difference between chrome plating workers and control groups. MN and NA frequencies in chrome plating workers were significantly higher than those in control groups (p < 0.05) and also significantly related to smoking habit (P < 0.05). A significant difference in NA was observed in workers exposed to chromium for longer duration. In addition to this, a higher degree of NA was observed among smokers. MN and other NA reflect genetic changes, events associated with carcinogenesis. Therefore the results of this study indicate that chrome plating workers are under risk of significant cytogenetic damage. Therefore, there is a need to educate those who work with heavy metals about the potential hazard of occupational exposure and the importance of using protective measures.

  4. Elevated Frequencies of Micronuclei and other Nuclear Abnormalities of Chrome Plating Workers Occupationally Exposed to Hexavalent Chromium

    PubMed Central

    Sudha, S; Kripa, SK; Shibily, P; Shyn, J

    2011-01-01

    Background Biomonitoring provides a useful tool to estimate the genetic risk from exposure to genotoxic agents. The aim of this study was to assess the potential cytogenetic damage associated with occupational exposure to hexavalent chromium by using micronuclei (MN) as a biomarker. Methods This was a cross-sectional study and all participants were males. Both the exposed and control individuals were selected from Coimbatore, Southern India. Exfoliated buccal cells from 44 chrome plating workers and 40 age and sex matched control subjects were examined for MN frequency and nuclear abnormalities (NA) other than micronuclei, such as binucleates, broken eggs, karyorrhexis, karyolysis and pyknosis. Results Results showed statistically significant difference between chrome plating workers and control groups. MN and NA frequencies in chrome plating workers were significantly higher than those in control groups (p < 0.05) and also significantly related to smoking habit (P < 0.05). A significant difference in NA was observed in workers exposed to chromium for longer duration. In addition to this, a higher degree of NA was observed among smokers. Conclusion MN and other NA reflect genetic changes, events associated with carcinogenesis. Therefore the results of this study indicate that chrome plating workers are under risk of significant cytogenetic damage. Therefore, there is a need to educate those who work with heavy metals about the potential hazard of occupational exposure and the importance of using protective measures. PMID:26328050

  5. Primary DNA damage in chrome-plating workers.

    PubMed

    Gambelunghe, A; Piccinini, R; Ambrogi, M; Villarini, M; Moretti, M; Marchetti, C; Abbritti, G; Muzi, G

    2003-06-30

    In order to evaluate the primary DNA damage due to occupational exposure to chromium (VI), DNA strand-breaks and apoptosis in peripheral lymphocytes were measured in a group of 19 chrome-plating workers. DNA strand-breaks was assessed by alkaline (pH>13) single-cell microgel electrophoresis ('comet') assay, while apoptosis was measured by flow-cytometry after propidium iodide staining of the cells. Concentrations of chromium in urine, erythrocytes and lymphocytes were investigated as biological indicators of exposure. A group of 18 hospital workers (control group I) and another 20 university personnel (control group II) without exposure to chromium were also studied as controls. The results of the study show that chrome-plating workers have higher levels of chromium in urine, erythrocytes and lymphocytes than unexposed workers. Comet tail moment values, assumed as index of DNA damage, are increased in chromium-exposed workers and results are significantly correlated to chromium lymphocyte concentrations. No difference emerged in the percentage of apoptotic nuclei in exposed and unexposed workers. The study confirms that measurements of chromium in erythrocytes and lymphocytes may provide useful information about recent and past exposure to hexavalent chromium at the workplace. The increase in DNA strand-breaks measured by comet assay suggests this test is valid for the biological monitoring of workers exposed to genotoxic compounds such as chromium (VI).

  6. Lung cancer in Yorkshire chrome platers, 1972-97

    PubMed Central

    Sorahan, T.; Harrington, J

    2000-01-01

    OBJECTIVES—To investigate mortality from lung cancer in chrome platers, a group exposed to chromic acid.
METHODS—The mortality of a cohort of 1087 chrome platers (920 men, 167 women) from 54 plants situated in the West Riding of Yorkshire, United Kingdom, was investigated for the period 1972-97. All subjects were employed as chrome platers for ⩾3 months and all were alive on 31 May 1972. Mortality data were also available for a cohort of 1163 comparison workers with no known occupational exposure to chrome compounds (989 men, 174 women). Information on duration of chrome work and smoking habits collected for a cross sectional survey carried out in 1969-72 were available for 916 (84.3%) of the chrome platers; smoking habits were available for 1004 (86.3%) comparison workers. Two analytical approaches were used, indirect standardisation and Poisson regression.
RESULTS—Based on serial mortality rates for the general population of England and Wales, significantly increased mortality from lung cancer was observed (obs) in male chrome platers (obs 60, expected (exp) 32.5, standardised mortality ratio (SMR) 185, p<0.001) but not in male comparison workers (obs 47, exp 36.9, SMR 127). Positive trends were not shown for duration of employment exposed to chrome, although data on working after 1972 were not available.
CONCLUSIONS—Confident interpretation is not possible but occupational exposures to hexavalent chromium may well have been involved in the increased mortality from lung cancer found in this cohort of chrome platers.


Keywords: chromium plating; lung cancer PMID:10810127

  7. Lipid peroxidation in workers exposed to hexavalent chromium.

    PubMed

    Huang, Y L; Chen, C Y; Sheu, J Y; Chuang, I C; Pan, J H; Lin, T H

    1999-02-26

    The aim of this study was to investigate whether exposure to hexavalent chromium induces lipid peroxidation in human. This study involved 25 chrome-plating factory workers and a reference group of 28 control subjects. The whole-blood and urinary chromium concentrations were determined by graphite furnace atomic absorption spectrophotometry. Malondialdehyde (MDA), the product of lipid peroxidation, was determined by high-performance liquid chromatography, and the activities of protective enzymes were measured by ultraviolet-visible spectrophotometry. In the chrome-plating workers, the mean concentrations of chromium in blood and urine were 5.98 microg/L and 5.25 microg/g creatinine, respectively; the mean concentrations of MDA in blood and urine were 1.7 micromol/L and 2.24 micromol/g creatinine. The concentrations of both chromium and MDA in blood and urine were significantly higher in the chromium-exposed workers. The activities of superoxide dismutase (SOD), glutathione peroxidase (GPX), and catalase (CAT) were not markedly different between control and exposed workers. Data suggest that MDA may be used as a biomarker for occupational chromium exposure. Antioxidant enzymic activities are not a suitable marker for chromium exposure.

  8. Electrospark Deposition for the Repair of Army Main Battle Tank Components

    DTIC Science & Technology

    2006-07-01

    Inconel 718, and Inconel 625 were deposited onto low-alloy carbon steel and Inconel 718 substrates. 6.2 ESD Procedure Development (M1A1... Inconel 625 Inconel 718 Inconel 718 Inconel 718 Electrode diameter (in) 0.125 0.125 0.125 .125 0.125 0.125 Pulse rate (Hz) 400 400 400 400 400 400...coating Chrome plating Chrome plating Chrome plating Chrome plating Chrome plating Chrome plating Electrode alloy Inconel 718 Inconel

  9. The Effect of Inhaled Chromium on Different Exhaled Breath Condensate Biomarkers among Chrome-Plating Workers

    PubMed Central

    Caglieri, Andrea; Goldoni, Matteo; Acampa, Olga; Andreoli, Roberta; Vettori, Maria Vittoria; Corradi, Massimo; Apostoli, Pietro; Mutti, Antonio

    2006-01-01

    Chromium is corrosive, cytotoxic, and carcinogenic for humans and can induce acute and chronic lung tissue toxicity. The aim of this study was to investigate Cr levels in exhaled breath condensate (EBC) of workers exposed to Cr(VI) and to assess their relationship with biochemical changes in the airways by analyzing EBC biomarkers of oxidative stress, namely, hydrogen peroxide (H2O2) and malondialdehyde (MDA). EBC samples were collected from 24 chrome-plating workers employed in a chrome-plating plant both before and after the Friday work shift and before the work shift on the following Monday. Cr-EBC levels increased from the beginning (5.3 μg/L) to the end of Friday (6.4 μg/L) but were considerably lower on Monday morning (2.8 μg/L). A similar trend was observed for H2O2-EBC levels (which increased from 0.36 μM to 0.59 μM on Friday and were 0.19 μM on Monday morning) and MDA-EBC levels (which increased from 8.2 nM to 9.7 nM on Friday and were 6.6 nM on Monday). Cr-EBC levels correlated with those of H2O2-EBC (r = 0.54, p < 0.01) and MDA-EBC (r = 0.59, p < 0.01), as well as with urinary Cr levels (r = 0.25, p < 0.05). The results of this study demonstrate that EBC is a suitable matrix that can be used to investigate both Cr levels and biomarkers of free radical production sampling the epithelial-lining fluid of workers exposed to Cr(VI). PMID:16581543

  10. [New perspectives in biomonitoring of metallic elements: the example of hexavalent chromium].

    PubMed

    Mutti, A; De Palma, G; Goldoni, M

    2012-01-01

    Plating industry is an important productive sector in all the national territory, because of its contribution to a high number of industrial products and crafts. In the chrome plating sector there is a specific chemical risk due to the exposure to compounds containing hexavalent Chromium [Cr(VI)]. Exhaled breath condensate (EBC) has been used to study both acute and long term exposure to Cr(VI) in chrome plating workers. Cr-EBC correlates with specific oxidative stress biomarkers. Moreover, both total Cr and its hexavalent fraction can be measured in EBC, which therefore is a promising biological fluid to assess the absorbed dose at the target organ level, the pulmonary reduction kinetics of Cr(VI) and in general its local pneumotoxic effects. EBC collection and analysis could give additional information to the traditional measures performed during biomonitoring.

  11. Determination of hexavalent chromium in exhaled breath condensate and environmental air among chrome plating workers.

    PubMed

    Goldoni, Matteo; Caglieri, Andrea; Poli, Diana; Vettori, Maria Vittoria; Corradi, Massimo; Apostoli, Pietro; Mutti, Antonio

    2006-03-15

    Chromium speciation has attracted attention because of the different toxicity of Cr(III), which is considered relatively non-toxic, and Cr(VI), which can cross cell membranes mainly as a chromate anion and has been classified as a class I human carcinogen. The aims of the present study were to measure soluble Cr(VI) levels in environmental samples, to develop a simple method of quantifying Cr(VI) in exhaled breath condensate (EBC), and to follow the kinetics of EBC Cr(VI) in chrome plating workers.Personal air samples were collected from 10 chrome platers; EBC was collected from the same workers immediately after the work shift on Tuesday and before the work shift on the following Wednesday. Environmental and EBC Cr(VI) levels were determined by means of colorimetry and electrothermal absorption atomic spectrometry, respectively.The method of detecting Cr(VI) in environmental air was based on the extraction of the Cr(VI)-diphenylcarbazide (Cr(VI)-DPC) complex in 1-butanol, whereas EBC Cr(VI) was determined using a solvent extraction of Cr(VI) as an ion pair with tetrabutylammonium ion, and subsequent direct determination of the complex (Cr(VI)-DPC) in EBC.Kinetic data showed that airborne Cr(VI) was reduced by 50% in airway lining fluid sampled at the end of exposure and that there was a further 50% reduction after about 15 h. The persistence of Cr(VI) in EBC supports the use of EBC in assessing target tissue levels of Cr(VI).

  12. Risk Report on Perfluorooctanesulfonate (PFOS) as a Component of Mist Suppressants in Chrome-Plating Tanks

    DTIC Science & Technology

    2003-02-01

    Perfluorooctanesulfonate ( PFOS ) is a synthetic perfluorinated surfactant recently discovered to be ubiquitous in the environment. Animal data suggest...a high tolerance for PFOS , as does epidemiological analysis of workers in PFOS manufacturing plants. A suggested reference dose of 0.02 mg$kg/day is

  13. Determination of hexavalent chromium in exhaled breath condensate and environmental air among chrome plating workers

    PubMed Central

    Goldoni, Matteo; Caglieri, Andrea; Poli, Diana; Vettori, Maria Vittoria; Corradi, Massimo; Apostoli, Pietro; Mutti, Antonio

    2006-01-01

    Chromium speciation has attracted attention because of the different toxicity of Cr(III), which is considered relatively non-toxic, and Cr(VI), which can cross cell membranes mainly as a chromate anion and has been classified as a class I human carcinogen. The aims of the present study were to measure soluble Cr(VI) levels in environmental samples, to develop a simple method of quantifying Cr(VI) in exhaled breath condensate (EBC), and to follow the kinetics of EBC Cr(VI) in chrome plating workers. Personal air samples were collected from 10 chrome platers; EBC was collected from the same workers immediately after the work shift on Tuesday and before the work shift on the following Wednesday. Environmental and EBC Cr(VI) levels were determined by means of colorimetry and electrothermal absorption atomic spectrometry, respectively. The method of detecting Cr(VI) in environmental air was based on the extraction of the Cr(VI)-diphenylcarbazide (Cr(VI)–DPC) complex in 1-butanol, whereas EBC Cr(VI) was determined using a solvent extraction of Cr(VI) as an ion pair with tetrabutylammonium ion, and subsequent direct determination of the complex (Cr(VI)–DPC) in EBC. Kinetic data showed that airborne Cr(VI) was reduced by 50% in airway lining fluid sampled at the end of exposure and that there was a further 50% reduction after about 15 h. The persistence of Cr(VI) in EBC supports the use of EBC in assessing target tissue levels of Cr(VI). PMID:17047732

  14. Black chrome on commercially electroplated tin as a solar selecting coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1977-01-01

    The reflectance properties of black chrome electroplated on commercially electroplated tin were measured for various black chrome plating times for both the solar and infrared spectrum. The values of absorptance and emittance were calculated from the measured reflectance values. The results indicate that the optimum combination of the highest absorptance in the solar region and the lowest emittance in the infrared of the black chrome plated on commercially electroplated tin is obtained for a black chrome plating time of between one and two minutes.

  15. Refinement in black chrome for use as a solar selective coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1974-01-01

    Black chrome is significant as a solar selective coating because the current extensive use of black chrome in the electroplating industry as a durable decorative finish makes black chrome widely available on a commercial scale and potentially low in cost as a solar selective coating. Black-chrome deposits were modified by underplating with dull nickel or by being plated on rough surfaces. Both of these procedures increased the visible absorptance. There was no change in the infrared reflectance for the dull-nickel - black-chrome combination from that reported for the bright-nickel - black-chrome combination. However, the bright-nickel - black-chrome coating plated on rough surfaces indicated a slight decrease in infrared reflectance. As integrated over the solar spectrum for air mass 2, the reflectance of the dull-nickel - black-chrome coating was 0.077, of the bright-nickel - black-chrome coating plated on a 0.75-micron (30-microinch) surface was 0.070, of the bright-nickel - black-chrome coating plated on a 2.5 micron (100-microinch) surface was 0.064. The corresponding values for the bright-nickel - black-chrome coating on a 0.0125-micron (0.5-microinch) surface, two samples of black nickel, and two samples of Nextrel black paint were 0.132, 0.123, 0.133, and 0.033, respectively.

  16. Occupational asthma due to chrome and nickel electroplating

    PubMed Central

    Bright, P.; Burge, P. S.; O'Hickey, S. P.; Gannon, P. F.; Robertson, A. S.; Boran, A.

    1997-01-01

    BACKGROUND: Exposure to chromium during electroplating is a recognised though poorly characterised cause of occupational asthma. The first series of such patients referred to a specialist occupational lung disease clinic is reported. METHODS: The diagnosis of occupational asthma was made from a history of asthma with rest day improvement and confirmed by specific bronchial provocation testing with potassium dichromate and nickel chloride. RESULTS: Seven workers had been exposed to chrome and nickel fumes from electroplating for eight months to six years before asthma developed. One subject, although exposed for 11 years without symptoms, developed asthma after a single severe exposure during a ventilation failure. This was the only subject who had never smoked. The diagnosis was confirmed by specific bronchial challenges. Two workers had isolated immediate reactions, one a late asthmatic reaction, and four a dual response following exposure to nebulised potassium dichromate at 1-10 mg/ml. Two of the four subjects were also challenged with nebulised nickel chloride at 0.1-10 mg/ml. Two showed isolated late asthmatic reactions, in one at 0.1 mg/ml, where nickel was probably the primary sensitising agent. Four workers carried out two hourly measurements of peak expiratory flow over days at and away from work. All were scored as having occupational asthma using OASYS-2. Breathing zone air monitoring was carried out in 60 workers from four decorative and two hard chrome plating shops from workers with similar jobs to those sensitised. No measurement exceeded the current occupational exposure standard for chromate or nickel, the mean levels of chromate exposure for jobs similar to those of the affected workers were 9-15 micrograms/m3. CONCLUSION: Chrome used in electroplating is a potential cause of occupational asthma. Sensitivity to chrome in electroplaters may occur in situations where exposure levels are likely to be within the current exposure standards. There may be cross reactivity with nickel. Inhalation challenge with nebulised potassium dichromate solution is helpful in making the specific diagnosis where doubt exists. 


 PMID:9039236

  17. 77 FR 60285 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-03

    ... the MLG for chicken- wire cracks, corrosion, and chrome plate distress; repetitive magnetic particle... center axles of the MLG for chicken-wire cracks, corrosion, and chrome plate distress; repetitive... the MLG for chicken- wire cracks, corrosion, and chrome plate distress; do a magnetic particle...

  18. Lung cancer mortality in nickel/chromium platers, 1946-95.

    PubMed

    Sorahan, T; Burges, D C; Hamilton, L; Harrington, J M

    1998-04-01

    To investigate mortality from lung cancer in nickel/chromium platers. The mortality experience of a cohort of 1762 chrome workers (812 men, 950 women) from a large electroplating and light engineering plant in the Midlands, United Kingdom, was investigated for the period 1946-95. All subjects were first employed in chrome work at the plant during the period 1946-75, and had at least six months employment in jobs associated with exposure to chromic acid mist (hexavalent chromium). Detailed job histories were abstracted from original company personnel records and individual cumulative durations of employment in three types of chrome work were derived as time dependent variables (chrome bath work, other chrome work, any chrome work). Two analytical approaches were used--indirect standardisation and Poisson regression. Based on mortalities for the general population of England and Wales, male workers with some period of chrome bath work had higher lung cancer mortalities (observed deaths 40, expected deaths 25.41, standardised mortality ratio (SMR) 157, 95% confidence interval (95% CI) 113 to 214, p < 0.01) than did other male chrome workers (observed 9, expected 13.70, SMR 66, 95% CI 30 to 125). Similar findings were shown for female workers (chrome bath workers: observed 15, expected 8.57, SMR 175, 95% CI 98 to 289, p = 0.06; other chrome workers: observed 1, expected 4.37, SMR 23, 95% CI 1 to 127). Poisson regression was used to investigate risks of lung cancer relative to four categories of cumulative duration of chrome bath work and four categories of cumulative duration of other chrome work (none, < 1 y, 1-4 y, > or = 5 y). After adjusting for sex, age, calendar period, year of starting chrome work, period from first chrome work, and employment status (still employed v left employment), there was a significant positive trend (p < 0.05) between duration of chrome bath work and risks of mortality for lung cancer. Relative to a risk of unity for those chrome workers without any period of chrome bath work, risks were 2.83 (95% CI 1.47 to 5.45), 1.61 (95% CI 0.75 to 3.44), and 4.25 (95% CI 1.83 to 9.87) for the second, third, and fourth exposure categories, respectively. Duration of other chrome work was not a useful predictor of risks of lung cancer. Similar findings for both variables were obtained when adjustment was made for sex and age only. Similar findings for both variables were obtained relative to risk of chrome nasal ulceration. The findings are consistent with the hypothesis that soluble hexavalent chromium compounds are potent human lung carcinogens.

  19. Variation of solar-selective properties of black chrome with plating time

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.; Curtis, H. B.

    1975-01-01

    The spectral reflectance properties of a commercially prepared black chrome over dull nickel, both plated on steel, for various plating times of the black chrome were measured. The plating current was 180 amperes per square foot. Values of absorptance integrated over the solar spectrum, and of infrared emittance integrated over black-body radiation at 250 F were obtained. It is shown that plating between one and two minutes produces the optimum combination of highest heat absorbed and lowest heat lost by radiation.

  20. Quality Improvement of Chrome-Diamond Coatings on Flowing Chrome Plating

    NASA Astrophysics Data System (ADS)

    Belyaev, V. N.; Koslyuk, A. Yu; Lobunets, A. V.; Andreyev, A. S.

    2016-04-01

    The research results of the process of flowing chrome plating of internal surfaces of long-length cylindrical articles with the usage of electrolyte with ultra-dispersed diamonds when continuous article rotation, while chromium-plating, are presented. During experiments the following varying technological parameters: electrolyte temperature and article frequency rotation were chosen, and experimental samples were obtained. Estimation of porosity, micro-hardness, thickness of chrome coatings and uniformity were performed as well as the precipitation structure by the method of scanning electron microscopy. The results showed that the use of ultra-dispersed diamonds and realization of the scheme with rotation of detail-cathode when flowing chromium-plating allows one to increase servicing characteristics of the coating due to the decrease of grains size of chrome coating and porosity, and due to the increase of micro-hardness, so confirming the efficiency of using the suggested scheme of coating application and the given type of ultra-dispersed fillers when chromium-plating.

  1. Nasal manifestations in chromium industry workers.

    PubMed

    Aiyer, R G; Kumar, Gaurav

    2003-04-01

    People working in mines, plating factories, cement industries are mainly exposed to chrome substances, IIexavalent chromium has been implicated for its toxic effect on the nasal mucosa. Hereby we present a rare study of 28 patients who attended out patient department of Otorhinolaryngology at SSG Hospital, Baroda from a nearby chromium industry. This study aims to present various nasal manifestations of toxic effects of prolonged chromium exposure.

  2. Nanocrystalline Cobalt-Phosphorous Electroplating as an Alternative to Hard Chromium Electroplating

    DTIC Science & Technology

    2012-08-01

    Validate pulsed electrodeposition of Nanocrystalline Cobalt-Phosphorous (nCoP) alloy coatings as a Hard Chrome electroplating alternative for DoD...limits Cr+6  Cathode Efficiency Cr Plating *Co PEL is 20 µg/m3  ≈5X faster than Chrome plating  Increased throughput  One nCo-P tank can...replace several hard chrome tanks  Bath is Stable nCoP Plating Approaches 100% Efficiency  Process Comparison CoP Technical Approach

  3. Lung cancer in Yorkshire chrome platers, 1972-97.

    PubMed

    Sorahan, T; Harrington, J M

    2000-06-01

    To investigate mortality from lung cancer in chrome platers, a group exposed to chromic acid. The mortality of a cohort of 1087 chrome platers (920 men, 167 women) from 54 plants situated in the West Riding of Yorkshire, United Kingdom, was investigated for the period 1972-97. All subjects were employed as chrome platers for >/=3 months and all were alive on 31 May 1972. Mortality data were also available for a cohort of 1163 comparison workers with no known occupational exposure to chrome compounds (989 men, 174 women). Information on duration of chrome work and smoking habits collected for a cross sectional survey carried out in 1969-72 were available for 916 (84.3%) of the chrome platers; smoking habits were available for 1004 (86.3%) comparison workers. Two analytical approaches were used, indirect standardisation and Poisson regression. Based on serial mortality rates for the general population of England and Wales, significantly increased mortality from lung cancer was observed (obs) in male chrome platers (obs 60, expected (exp) 32.5, standardised mortality ratio (SMR) 185, p<0. 001) but not in male comparison workers (obs 47, exp 36.9, SMR 127). Positive trends were not shown for duration of employment exposed to chrome, although data on working after 1972 were not available. Confident interpretation is not possible but occupational exposures to hexavalent chromium may well have been involved in the increased mortality from lung cancer found in this cohort of chrome platers.

  4. Pathfinder Atomic Power Plant Nozzle Galling Test, Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    1961-12-29

    Galling tests of 304, 17-4PH, and chrome-plated 304 stainless-steel nozzles with 304 stainless-steel sleeves were conducted at Pathflnder reactor conditions of 480 deg F, 600 psig. A horizontal force was imposed on the sleeve with the nozzle inserted; and the nozzle was moved axially to determine galling tendencies. Galling was produced on both the 304 and 17-4PH stainless-steel nozzles. The chrome-plated 304-stainless-steel nozzles were cycled numerous times without galling. On the basis of these tests, chrome-plated 304-stainless- steel is the material selected for the Pathfinder boiler fuel-element nozzle.

  5. Electrodeposition of Nanocrystalline Co-P Coatings as a Hard Chrome Alternative (Briefing Charts)

    DTIC Science & Technology

    2011-02-10

    chrome plating utilizes chromium in the hexavalent state (Cr6+) Cr6+ is a known carcinogen and poses a health risk to operators OSHA lowered the Cr6+ PEL...from 52 µg/m3 to 5 µg/m3 8 Apr 09, Memorandum, DoD Directive Hexavalent Chromium Management Policy NAVAIR Cr6+ Authorization Process Hard Chrome...Systems Allocation (ESA) data extrapolated across all FRCs over a 10 yr period Environmental Driver/Benefit (Hexavalent Chromium Plating at Navy

  6. Clean Metal Finishing Alternatives

    DTIC Science & Technology

    2006-05-01

    Cr, must heat treat for hardness 4 4 Trivalent chrome Trivalent plating chemistry Varying success, some must be brush plate 3 3 Alloy plating...metals. Hard coating deposition unproven. 3 N/A Weld coating Electrospark Deposition/ Alloying (ESD/ ESA) Microarc welding Localized repair of non...Alternatives to chromate conversion coatings Al TriChrome Pretreatment (TCP)* – AnoChem TCP, Aluminescent, TCP-HF Trivalent Cr3+ conversion with Zr

  7. Black chrome solar selective coating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pettit, R.B.; Sowell, R.R.

    1980-01-01

    Electrodeposited black chrome solar selective coatings have frequently experienced thermal stability problems when heated to temperatures above 250/sup 0/C (480/sup 0/F) in air. By reducing the trivalent chromium concentration in the standard black chrome plating bath, coatings on nickel substrates are obtained which are stable for thousands of hours at 350/sup 0/C (660/sup 0/F) and for hundreds of hours at 400/sup 0/C (750/sup 0/F). These results have been obtained consistently on a laboratory scale, but difficulty in reproducing the results has been encountered in a production environment. A current study of the effects of known plating variables on the opticalmore » properties and thermal stability of coatings is aimed at establishing an acceptable range for each plating parameter. A preliminary process specification for electroplating mild steel substrates with a stable black chrome coating is presented.« less

  8. Superfund Record of Decision (EPA Region 5): Better Brite Plating Chrome and Zinc, De Pere, WI. (First remedial action), June 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The 2-acre Better Brite Plating Chrome and Zinc site is composed of two plating facilities in De Pere, Brown County, Wisconsin. The site includes the 1.5-acre Chrome Shop and the 0.5-acre Zinc Shop. Land use in the area is predominantly residential and commercial, with a wetlands located approximately one-quarter mile from the site. The estimated 15,000 area residents use the municipal wells drawing from the deep aquifer as a drinking water supply. The Zinc Shop has a long history of improper operational procedures and spills into the surrounding soil. The selected remedial action for this interim remedy includes continuing andmore » expanding the current operation of the ground water extraction system and pretreatment facility, which will include pretreatment of the additional water collected by the surface water and ground water collection systems, and the Chrome and Zinc shops, with discharge to the De Pere wastewater system.« less

  9. Characterization of Crystallographic Structure and Internal Stress of Chromium Coatings Plated under Current Interruptions.

    DTIC Science & Technology

    1983-09-01

    phase has a preferred orientation as most other electrodeposits, this peak found off the equatorial direction provided a way of measuring...40 (S)IoA) 1IliN3i0d , STANDARD HARD CHROM (KiC) INTERRUPTED PLATED CHROME (tC) -4’? 1001 1000X KC Chrome IC Chrome Bath Temperature *C 55 55 Current...COMMANDER ATTN: DRSNC- LC (D) I US ARMY TANK-AUTMV COWD DRSMC-LCE(D) 1 ATTN: DRSTA-RC DRSC-LCM(D) (BLDG 321) 1 WARREN, MI 48090 DRSMC- LCS (D) 1 DRSNC-LCU

  10. Changes Found on Run-In and Scuffed Surfaces of Steel Chrome Plate, and Cast Iron

    NASA Technical Reports Server (NTRS)

    Good, J. N.; Godfrey, Douglas

    1947-01-01

    A study was made of run-in and scuffed steel, chrome-plate, and cast-iron surfaces. X-ray and electron diffraction techniques, micro-hardness determinations, and microscopy were used. Surface changes varied and were found to include three classes: chemical reaction, hardening, and crystallite-size alteration. The principal chemical reactions were oxidation and carburization.

  11. Chemometrics models for assessment of oxidative stress risk in chrome-electroplating workers.

    PubMed

    Zendehdel, Rezvan; Shetab-Boushehri, Seyed Vahid; Azari, Mansoor R; Hosseini, Vajihe; Mohammadi, Hamidreza

    2015-04-01

    Oxidative stress is the main cause of hexavalant chromium-induced damage in chrome electroplating workers. The main goal of this study is toxicity analysis and the possibility of toxicity risk categorizing in the chrome electroplating workers based on oxidative stress parameters as prognostic variables. We assessed blood chromium levels and biomarkers of oxidative stress such as lipid peroxidation, thiol (SH) groups and antioxidant capacity of plasma. Data were subjected to principle component analysis (PCA) and artificial neuronal network (ANN) to obtain oxidative stress pattern for chrome electroplating workers. Blood chromium levels increased from 4.42 ppb to 10.6 ppb. Induction of oxidative stress was observed by increased in lipid peroxidation (22.38 ± 10.47 μM versus 14.74 ± 4.82 μM, p < 0.0008), decreased plasma antioxidant capacity (3.17 ± 1.35 μM versus 7.74 ± 4.45 μM, p < 0.0001) and plasma total thiol (SH groups) (0.21 ± 0.07 μM versus 0.45 ± 0.41 μM, p < 0.0042) in comparison to controls. Based on the oxidative parameters, two groups were identified by PCA methods. One category is workers with the risk of oxidative stress and second group is subjects with probable risk of oxidative stress induction. ANN methods can predict oxidative-risk category for assessment of toxicity induction in chrome electroplaters. The result showed multivariate modeling can be interpreted as the induced biochemical toxicity in the workers exposed to hexavalent chromium. Different occupation groups were assessed on the basis of risk level of oxidative stress which could further justify proceeding engineering control measures.

  12. Alternatives To Cadmium Plated Military Connectors

    DTIC Science & Technology

    2011-08-30

    from Feb 2011 Asets Defense conference  Amphenol Aerospace Operations report. 9/21/2011 10 Chromate finish  Hexavalent chrome was targeted by DOD...Fluorocarbon Zinc-Nickel Pure Dense Aluminum  Zinc-Nickel and Aluminum currently contain hexavalent chromate. Nickel-Fluorocarbon requires no...to lack of available drop in replacements, but this will change as alternatives become available.  Trivalent chrome and other non- chrome

  13. [Exposure to metal compounds in occupational galvanic processes].

    PubMed

    Surgiewicz, Jolanta; Domański, Wojciech

    2006-01-01

    Occupational galvanic processes are provided in more than 600 small and medium enterprises in Poland. Workers who deal with galvanic coating are exposed to heavy metal compounds: tin, silver, copper and zinc. Some of them are carcinogenic, for example, hexavalent chromium compounds, nickel and cadmium compounds. Research covered several tens of workstations involved in chrome, nickel, zinc, tin, silver, copper and cadmium plating. Compounds of metals present in the air were determined: Cr, Ni, Cd, Sn, Ag--by atomic absorption spectrometry with electrothermal atomization (ET-AAS) and Zn--by atomic absorption spectrometry with flame atomization (F-AAS). The biggest metal concentrations--of silver and copper--were found at workstations of copper, brass, cadmium, nickel and chrome plating, conducted at the same time. Significant concentrations of copper were found at workstations of maintenance bathing and neutralizing of sewage. The concentrations of metals did not exceed Polish MAC values. MAC values were not exceeded for carcinogenic chromium(VI), nickel or cadmium, either. In galvanic processes there was no hazard related to single metals or their compounds, even carcinogenic ones. Combined exposure indicators for metals at each workstation did not exceed 1, either. However, if there are even small quantities of carcinogenic agents, health results should always be taken into consideration.

  14. Selective coating for solar panels. [using black chrome and black nickel

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E. (Inventor)

    1977-01-01

    The energy absorbing properties of solar heating panels are improved by depositing a black chrome coating of controlled thickness on a specially prepared surface of a metal substrate. The surface is prepared by depositing a dull nickel on the substrate, and the black chrome is plated on this low emittance surface to a thickness between 0.5 micron and 2.5 microns.

  15. Reducing chromium losses from a chromium plating bath. 1987 summer intern report. Project conducted at New Dimension Plating, Hutchinson, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Achman, D.

    1987-12-31

    The company employs about forty people and operates for one or two eight hour shifts with an average of 315 racks of chrome plating per eight hour day. They plate a variety of metals including copper, nickel, gold, brass and chromium. Chromium is the major metal plated and is usually the last step in plating cycle. Most parts are copper plated and then nickel plated in preparation for chrome plating. The main difference between New Dimension Plating and other plating shops is the variety of parts plated. As New Dimension Plating is a job shop, a wide range of partsmore » such as motorcycle accessories, stove parts, and custom items are metal finished. The plating lines are manual, meaning employees dip the racks into the tanks by hand. This fact along with the fact that parts vary greatly in size and shape accounts for the significant drag-out on the chromium plating line.« less

  16. CAPSULE REPORT: HARD CHROME FUME SUPPRESSANTS & CONTROL TECHNOLOGIES

    EPA Science Inventory

    All existing information which includes the information extrapolated from the Hard Chrome Pollution Prevention Demonstration Project(s) and other sources derived from plating facilities and industry contacts, will be condensed and featured in this document. At least five chromium...

  17. Influences of the current density on the performances of the chrome-plated layer in deterministic electroplating repair

    NASA Astrophysics Data System (ADS)

    Xia, H.; Shen, X. M.; Yang, X. C.; Xiong, Y.; Jiang, G. L.

    2018-01-01

    Deterministic electroplating repair is a novel method for rapidly repairing the attrited parts. By the qualitative contrast and quantitative comparison, influences of the current density on performances of the chrome-plated layer were concluded in this study. The chrome-plated layers were fabricated under different current densities when the other parameters were kept constant. Hardnesses, thicknesses and components, surface morphologies and roughnesses, and wearability of the chrome-plated layers were detected by the Vickers hardness tester, scanning electron microscope / energy dispersive X-ray detector, digital microscope in the 3D imaging mode, and the ball-milling instrument with profilograph, respectively. In order to scientifically evaluate each factor, the experimental data was normalized. A comprehensive evaluation model was founded to quantitative analyse influence of the current density based on analytic hierarchy process method and the weighted evaluation method. The calculated comprehensive evaluation indexes corresponding to current density of 40A/dm2, 45A/dm2, 50A/dm2, 55A/dm2, 60A/dm2, and 65A/dm2 were 0.2246, 0.4850, 0.4799, 0.4922, 0.8672, and 0.1381, respectively. Experimental results indicate that final optimal option was 60A/dm2, and the priority orders were 60A/dm2, 55A/dm2, 45A/dm2, 50A/dm2, 40A/dm2, and 65A/dm2.

  18. Special Advanced Studies for Pollution Prevention. Delivery Order 0046: Advanced Studies in Pollution Prevention Chrome Replacements for Internal and Small Parts

    DTIC Science & Technology

    1999-01-01

    Control Conference Proceedings, Orlando (1997), p 143. 5 US Patent # 5,196,109 (1993): " Trivalent chromium electrolytes and plating processes...Summary -Electroplating 7.1. Introduction 7.2. Process Description 7.2.1 Trivalent chrome plating 7.2.2. Composite electroplating 7.2.3. Alloy...requirements of chromium without the environmental and health hazards associated with chromic acid. Ideally, the process would not use any EPA 17

  19. Feasibility of Biological Effective Monitoring of Chrome Electroplaters to Chromium through Analysis of Serum Malondialdehyde.

    PubMed

    Mozafari, P; Rezazadeh Azari, M; Shokoohi, Y; Sayadi, M

    2016-10-01

    Great concern about occupational exposure to chromium (Cr [VI]) has been reported due to escalated risk of lung cancer in exposed workers. Consequences of occupational exposure to Cr (VI) have been reported as oxidative stress and lung tissue damage. To investigate the feasibility of biological effect monitoring of chrome electroplaters through analysis of serum malondialdehyde (MDA). 90 workers directly involved in chrome electroplating---categorized into three equal groups based on their job as near bath workers, degreaser, and washers---and 30 workers without exposure to Cr (VI), served as the control group, were studied. Personal samples were collected and analyzed according to NIOSH method 7600. Serum MDA level was measured by HPLC using a UV detector. Median Cr (VI) exposure level was 0.38 mg/m(3) in near bath workers, 0.20 mg/m(3) in degreasers, and 0.05 mg/m(3) in washers. The median serum MDA level of three exposed groups (2.76 μmol/L) was significantly (p<0.001) higher than that in the control group (2.00 μmol/L). There was a positive correlation between electroplaters' level of exposure to Cr (VI) and their serum MDA level (Spearman's ρ 0.806, p<0.001). Serum MDA level is a good biomarker for the level of occupational exposure to Cr (VI) in electroplaters.

  20. A demonstration of NIOSH push-pull ventilation criteria.

    PubMed

    Klein, M K

    1987-03-01

    This paper summarizes the results of a study performed on an actual chrome plating tank in order to validate criteria for push-pull ventilation systems developed by Huebener and Hughes at NIOSH. Validation of the criteria was made by taking area industrial hygiene samples for hexavalent and total chrome at ten locations around the plating tank. The sampling was performed during actual production runs or while the tank was operating with a dummy load. The sampling data are summarized. The data show that the push-pull system, operating at Huebener's criteria, could control emissions to below the current standards and guidelines. Conclusions and recommendations are included.

  1. Fundamental studies of black chrome for solar collector use

    NASA Technical Reports Server (NTRS)

    Mcdonald, G.; Buzek, B.; Curtis, H.

    1976-01-01

    The thicknesses of black chrome plated for various times have been measured from electron photomicrographs and correlated with the solar spectrum absorptance and infrared emittance as calculated from spectral reflectance measurements. The maximum absorptance is reached at an average thickness of 0.5 micrometer. The emittance increases only slightly up to 1.0 micrometer but increases rapidly at thickness above 1.0 micrometer.

  2. Chromium Elimination and Cannon Life Extension for Gun Tubes

    DTIC Science & Technology

    2012-08-30

    the use of hexavalent chromium (VI) in the production of cannon barrels by developing a cost effective environmentally friendly Explosive Bonding...erosion- resistant chrome cobalt alloy matrix with 15% tungsten. Stellite is used as M60 machine gun barrel liner. Tantalum Cobalt Tungsten...Grounds (YPG) Preliminary proof of principle endurance testing at YPG shows promising results when conducted side by side to a chrome plated

  3. Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene

    PubMed Central

    Cowie, Raelene M; Carbone, Silvia; Aiken, Sean; Cooper, John J; Jennings, Louise M

    2016-01-01

    Calcium sulfate bone void fillers are increasingly being used for dead space management in infected arthroplasty revision surgery. The presence of these materials as loose beads close to the bearing surfaces of joint replacements gives the potential for them to enter the joint becoming trapped between the articulating surfaces; the resulting damage to cobalt chrome counterfaces and the subsequent wear of ultra-high-molecular-weight polyethylene is unknown. In this study, third-body damage to cobalt chrome counterfaces was simulated using particles of the calcium sulfate bone void fillers Stimulan® (Biocomposites Ltd., Keele, UK) and Osteoset® (Wright Medical Technology, TN, USA) using a bespoke rig. Scratches on the cobalt chrome plates were quantified in terms of their density and mean lip height, and the damage caused by the bone void fillers was compared to that caused by particles of SmartSet GMV PMMA bone cement (DePuy Synthes, IN, USA). The surface damage from Stimulan® was below the resolution of the analysis technique used; SmartSet GMV caused 0.19 scratches/mm with a mean lip height of 0.03 µm; Osteoset® led to a significantly higher number (1.62 scratches/mm) of scratches with a higher mean lip height (0.04 µm). Wear tests of ultra-high-molecular-weight polyethylene were carried out in a six-station multi-axial pin on plate reciprocating rig against the damaged plates and compared to negative (highly polished) and positive control plates damaged with a diamond stylus (2 µm lip height). The wear of ultra-high-molecular-weight polyethylene was shown to be similar against the negative control plates and those damaged with third-body particles; there was a significantly higher (p < 0.001) rate of ultra-high-molecular-weight polyethylene wear against the positive control plates. This study showed that bone void fillers of similar composition can cause varying damage to cobalt chrome counterfaces. However, the lip heights of the scratches were not of sufficient magnitude to increase the wear of ultra-high-molecular-weight polyethylene above that of the negative controls. PMID:27312481

  4. Industrial Processes to Reduce Generation of Hazardous Waste at DoD Facilities. Phase III Report. Appendix B. Workshop Manual Innovative Hard Chrome Plating, Pensacola Naval Air Rework Facility, Pensacola, Florida.

    DTIC Science & Technology

    1985-12-01

    The first cases of occupational health effects from hexa- 1. Chromium metals and alloys valent chromium were reported in 1827(2) by Cumin , who .. This...however, has reported an increase in lung Costa et ap4) in 1916 described chrome ulcers in tanners and other cancers in chrome platers in England. and... cancer risk. With the data 2.8 mg/m 3 (as Cr6). Levels of Cr6 in the form of chromi- available, however, this TLV provides an ade- urn trioxide, were

  5. Establishment of Wear Resistant HVOF Coatings for 50CrMo4 Chromium Molybdenum Alloy Steel as an Alternative for Hard Chrome Plating

    NASA Astrophysics Data System (ADS)

    Karuppasamy, S.; Sivan, V.; Natarajan, S.; Kumaresh Babu, S. P.; Duraiselvam, M.; Dhanuskodi, R.

    2018-05-01

    High cost imported components of seamless steel tube manufacturing plants wear frequently and need replacement to ensure the quality of the product. Hard chrome plating, which is time consuming and hazardous, is conventionally used to restore the original dimension of the worn-out surface of the machine components. High Velocity Oxy-Fuel (HVOF) thermal spray coatings with NiCrBSi super alloy powder and Cr3C2 NiCr75/25 alloy powder applied on a 50CrMo4 (DIN-1.7228) chromium molybdenum alloy steel, the material of the wear prone machine component, were evaluated for use as an alternative for hard chrome plating in this present work. The coating characteristics are evaluated using abrasive wear test, sliding wear test and microscopic analysis, hardness test, etc. The study results revealed that the HVOF based NiCrBSi and Cr3C2NiCr75/25 coatings have hardness in the range of 800-900 HV0.3, sliding wear rate in the range of 50-60 µm and surface finish around 5 microns. Cr3C2 NiCr75/25 coating is observed to be a better option out of the two coatings evaluated for the selected application.

  6. CAPSULE REPORT: HARD CHROME FUME ...

    EPA Pesticide Factsheets

    All existing information which includes the information extrapolated from the Hard Chrome Pollution Prevention Demonstration Project(s) and other sources derived from plating facilities and industry contacts, will be condensed and featured in this document. At least five chromium emission prevention/control devices have been tested covering a wide spectrum of techniques currently in use at small and large-sized chrome metal plating shops. The goal for limiting chromium emissions to levels specified in the MACT Standards are: (1) 0.030 milligrams per dry standard cubic meter of air (mg/dscm) for small facilities with existing tanks, (2) 0.015 mg/dscm for small facilities with new tanks or large facilities with existing or new tanks. It should be emphasized that chemical mist suppressants still have quality issues and work practices that need to be addressed when they are used. Some of the mist suppressants currently in use are: one-, two-, and three-stage mesh pad mist eliminators; composite mesh pad mist eliminators; packed-bed scrubbers and polyballs. This capsule report should, redominantly, emphasize pollution prevention techniques and include, but not be restricted to, the afore-mentioned devices. Information

  7. Tissue Photolithography

    NASA Technical Reports Server (NTRS)

    Wade, Lawrence A.; Kartalov, Emil; Shibata, Darryl; Taylor, Clive

    2011-01-01

    Tissue lithography will enable physicians and researchers to obtain macromolecules with high purity (greater than 90 percent) from desired cells in conventionally processed, clinical tissues by simply annotating the desired cells on a computer screen. After identifying the desired cells, a suitable lithography mask will be generated to protect the contents of the desired cells while allowing destruction of all undesired cells by irradiation with ultraviolet light. The DNA from the protected cells can be used in a number of downstream applications including DNA sequencing. The purity (i.e., macromolecules isolated form specific cell types) of such specimens will greatly enhance the value and information of downstream applications. In this method, the specific cells are isolated on a microscope slide using photolithography, which will be faster, more specific, and less expensive than current methods. It relies on the fact that many biological molecules such as DNA are photosensitive and can be destroyed by ultraviolet irradiation. Therefore, it is possible to protect the contents of desired cells, yet destroy undesired cells. This approach leverages the technologies of the microelectronics industry, which can make features smaller than 1 micrometer with photolithography. A variety of ways has been created to achieve identification of the desired cell, and also to designate the other cells for destruction. This can be accomplished through chrome masks, direct laser writing, and also active masking using dynamic arrays. Image recognition is envisioned as one method for identifying cell nuclei and cell membranes. The pathologist can identify the cells of interest using a microscopic computerized image of the slide, and appropriate custom software. In one of the approaches described in this work, the software converts the selection into a digital mask that can be fed into a direct laser writer, e.g. the Heidelberg DWL66. Such a machine uses a metalized glass plate (with chrome metallization) on which there is a thin layer of photoresist. The laser transfers the digital mask onto the photoresist by direct writing, with typical best resolution of 2 micrometers. The plate is then developed to remove the exposed photoresist, which leaves the exposed areas susceptible to chemical chrome etch. The etch removes the unprotected chrome. The rest of the photoresist is then removed, by either ultraviolet organic solvent or over-development. The remaining chrome pattern is quickly oxidized by atmospheric exposure (typically within 30 seconds). The ready chrome mask is now applied to the tissue slide and aligned manually, or using automatic software and pre-designed alignment marks. The slide plate sandwich is then exposed to UV to destroy the DNA of the unwanted cells. The slide and plate are separated and the slide is processed in a standard way to prepare for polymerase chain reaction (PCR) and potential identification of cancer sequences.

  8. DNA-protein crosslinks in peripheral lymphocytes of individuals exposed to hexavalent chromium compounds.

    PubMed

    Zhitkovich, A; Lukanova, A; Popov, T; Taioli, E; Cohen, H; Costa, M; Toniolo, P

    1996-01-01

    Abstract DNA-protein crosslinks were measured in peripheral blood lymphocytes of chrome-platers and controls from Bulgaria in order to evaluate a genotoxic effect of human exposure to carcinogenic Cr(VI) compounds. Chrome-platers and most of the unexposed controls were from the industrial city of Jambol; some additional controls were recruited from the seaside town of Burgas. The chrome-platers had significantly elevated levels of chromium in pre- and post-shift urine, erythrocytes and lymphocytes compared with the control subjects. The largest differences between the two groups were found in erythrocyte chromium concentrations which are considered to be indicative of Cr(VI) exposure. Despite the significant differences in internal chromium doses, levels of DNA-protein crosslinks were not significantly different between the combined controls and exposed workers. Individual DNA-protein crosslinks, however, correlated strongly with chromium in erythrocytes at low and moderate doses but at high exposures, such as among the majority of chrome-platers, these DNA adducts were saturated at maximum levels. The saturation of DNA-protein crosslinks seems to occur at 7-8 μg I-(1) chromium in erythrocytes whereas a mean erythrocyte chromium among the chrome platers was as high as 22.8 μg l(-1). Occupationally unexposed subjects exhibited a significant variability with respect to the erythrocyte chromium concentration, however erythrocyte chromium levels correlated closely with DNA-protein crosslinks in lymphocytes. The controls from Jambol had higher chromium concentrations in erythrocytes and elevated levels of DNA-protein crosslinks compared with Burgas controls. Occupational exposure to formaldehyde among furniture factory workers did not change levels of DNA-protein crosslinks in peripheral lymphocytes. DNA-protein crosslink measurements showed a low intraindividual variability and their levels among both controls and exposed indivduals were not affected by smoking, age or weight.

  9. The effect of chrome adhesion layer on quartz resonator aging.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wessendorf, Kurt O.; Ohlhausen, James Anthony

    2011-03-01

    This SAND report documents a late start LDRD designed to determine the possible aging effects of a quartz resonator gold adhesion layer. Sandia uses quartz resonators for applications. These applications require a very stable frequency source with excellent aging (low drift) characteristics. These parts are manufactured by one of our qualified vendors outside Sandia Laboratories, Statek Corp. Over the years we, Sandia and the vendor, have seen aging variations that have not been completely explained by the typical mechanisms known in the industry. One theory was that the resonator metallization may be contributing to the resonator aging. This LDRD wouldmore » allow us to test and analyze a group of resonators with known differentiating metallization and via accelerated aging determine if a chrome adhesion layer used to accept the final gold plating may contribute to poor aging. We worked with our main vendor to design and manufacture a set of quartz resonators with a wide range of metallization thickness ratios between the chrome and gold that will allow us determine the cause of this aging and which plating thickness ratios provide the best aging performance while not degrading other key characteristics.« less

  10. Low temperature selective absorber research

    NASA Astrophysics Data System (ADS)

    Herzenberg, S. A.; Silberglitt, R.

    1982-04-01

    Research carried out since 1979 on selective absorbers is surveyed, with particular attention given to the low-temperature coatings seen as promising for flat plate and evacuated tube applications. The most thoroughly investigated absorber is black chrome, which is highly selective and is the most durable low-temperature absorber. It is believed that other materials, because of their low cost and lower content of strategic materials, may eventually supplant black chrome. Among these candidates are chemically converted black nickel; anodically oxidized nickel, zinc, and copper composites; and nickel or other low-cost multilayer coatings. In reviewing medium and high-temperature research, black chrome, multilayer coatings and black cobalt are seen as best medium-temperature candidates. For high temperatures, an Al2O3/Pt-Al203 multilayer composite or the zirconium diboride coating is preferred.

  11. Effects of Nonadecafluorodecanoic Acid on Tissue Fatty Acids of the Rat.

    DTIC Science & Technology

    1982-01-01

    REVIEW Perfluorinated compounds have wide application. Perfluorocarboxylic and perfluorosulfonic acids have found commercial utilization in plating...readily obtainable in crystalline form. 1 Perfluorocarboxylic and perfluorosulfonic acids are used commercially in plating systems and as wetting agents...are generally considered to be metaboli- cally inert, but perfluorohexane causes reduction of microsomal cyto- chrome P-450 in vitro and perfluoro -n

  12. Industrial Processes to Reduce Generation of Hazardous Waste at DoD facilities. Phase 3 Report. Summary of Projects of Excellence Workshops

    DTIC Science & Technology

    1985-12-01

    cation impurities from the plating solution and anodes to oxidize trivalent chromium to hexavalent chromium . Hexa- . valent chromium ions remain on the...corrosion, or to improve its engineering properties (harlness, durability, solderability, or frictional characteristics). Chromium ic used principally...facturing consists of machining the worn part or stripping a portion of the old plate, overplating it with a thick layer of chromium (hard chrome plating

  13. Hardening parts by chrome plating in manufacture and repair

    NASA Astrophysics Data System (ADS)

    Astanin, V. K.; Pukhov, E. V.; Stekolnikov, Y. A.; Emtsev, V. V.; Golikova, O. A.

    2018-03-01

    In the engineering industry, galvanic coatings are widely used to prolong the service life of the machines, which contribute to the increase in the strength of the parts and their resistance to environmental influences, temperature and pressure drops, wear and fretting corrosion. Galvanic coatings have been widely applied in engineering, including agriculture, aircraft building, mining, construction, and electronics. The article focuses on the manufacturing methods of new agricultural machinery parts and the repair techniques of worn parts by chrome plating. The main attention is paid to the unstable methods of chromium deposition (in pulsed and reversing modes) in low-concentration electrolytes, which makes it possible to increase the reliability and durability of the hardened parts operation by changing the conditions of electrocrystallization, that is, directed formation of the structure and texture, thickness, roughness and microhardness of chromium plating. The practical recommendations are given on the current and temperature regimes of chromium deposition and composition of baths used for the restoration and hardening of the machine parts. Moreover, the basic methods of machining allowances removal are analysed.

  14. Single-Cylinder Oil-Control Tests of Porous Chrome-Plated Cylinder Barrels for Radial Air-Cooled Engines

    DTIC Science & Technology

    1946-01-01

    plating, it will affect a choke as desired in the cylinder. When the clearance between the anode and the cathode (cylinder barrel) is decreased, an...National Advisory Commltteo for Aeronautics, Cltivel« oid , Ohio. RSFEFKICE3 1. Johnson, Robert L., wad Anderson, Roy I.: S.’.nglo-Cylindor Engine Tests...plating a choke in the bore. Choice la obtained by decreasing the clear- ance between the anode and the cylinder barrel ( cathode ). Taper on anode la

  15. REACH Compliant Hexavalent Chrome Replacement for Corrosion Protection (HITEA)

    DTIC Science & Technology

    2014-11-01

    3 The Role of the AAD and Materials KTNs • A joint AAD and Materials KTN workshop in 2011 resulted in: - Definition of the hexavalent chromium ...Alloy Nimonic alloy Hard chrome plating x x x TiN x x CrN x x DLC x WC/C x x x PEO x x Co-P x x x x x x Trivalent Cr x x x x x x Filled ENP x x 8...aims to establish a fast, inexpensive and robust testing methodology for selecting the most promising chromium -free alternatives. • Creation of a

  16. In-Service Evaluation of HVOF Coated Main Landing Gear on Navy P-3 Aircraft

    NASA Technical Reports Server (NTRS)

    Devereaux, jon L.; Forrest, Clint

    2008-01-01

    Due to the environmental and health concerns with Electroplated Hard Chrome (EHC), the Hard Chrome Alternatives Team (HCAT) has been working to provide an alternative wear coating for EHC. The US Navy selected Tungsten-Carbide Cobalt (WC- 17Co) High Velocity Oxy-Fuel (HVOF) thermal spray coating for this purpose and completed service evaluations on select aircraft components to support the HCAT charter in identifying an alternative wear coating for chrome plating. Other benefits of WC-Co thermal spray coatings over EHC are enhanced corrosion resistance, improved durability, and exceptional wear properties. As part of the HCAT charter and to evaluate HVOF coatings on operational Navy components, the P-3 aircraft was selected for a service evaluation to determine the coating durability as compared to chrome plating. In April 1999, a VP-30 P-3 aircraft was outfitted with a right-hand Main Landing Gear (MLG) shock strut coated with WCCo HYOF thermal spray applied to the piston barrel and four axle journals. The HVOF coating on the piston barrel and axle journals was applied by Southwest United Industries, Inc. This HVOF coated strut assembly has since completed 6,378 landings. Teardown analysis .for this WC-Co HVOF coated MLG asset is significant in assessing the durability of this wear coating in service relative to EHC and to substantiate Life Cycle Cost (LCC) data to support a retrograde transition from EHC to HVOF thermal spray coatings. Findings from this teardown analysis may also benefit future transitions to HVOF thermal spray coatings by identifying enhancements to finishing techniques, mating bearing and liner material improvements, improved seal materials, and improvements in HVOF coating selection.

  17. TACOM LCMC Industrial Base Engineering Support - Board of Directors

    DTIC Science & Technology

    2011-07-01

    Hex Chrome Replacement (High Purity Aluminum) Capability o Advanced Aviation Forward Area Refueling System (AAFARS)Tech Data Development o Common...SIAD (As needed) Example Issues: • Hexavalent Chromium/Cadmium (RRAD) • Common Adhesive (ANAD) • AVLB Pressure Plate (ANAD) • Paladin Corrosion

  18. Hazardous effects of effluent from the chrome plating industry: 70 kDa heat shock protein expression as a marker of cellular damage in transgenic Drosophila melanogaster (hsp70-lacZ).

    PubMed Central

    Mukhopadhyay, Indranil; Saxena, Daya Krishna; Chowdhuri, Debapratim Kar

    2003-01-01

    Hazardous effects of an effluent from the chrome plating industry were examined by exposing transgenic Drosophila melanogaster (hsp70-lacZ) to various concentrations (0.05, 0.1, 1.0, 10.0, and 100.0 micro L/mL) of the effluent through diet. The emergence pattern of adult flies was affected, along with impaired reproductive performance at the higher dietary concentrations of the effluent. Interestingly, the effect of the effluent was more pronounced in male than in female flies. The effect of the effluent on development of adult flies was concurrent with the expression pattern of the heat shock protein 70 gene (hsp70), both in larval tissues and in the reproductive organs of adult flies. We observed a dose- and time-dependent expression of hsp70 in third instar larvae exposed for different time intervals. Absence of hsp70 expression in larvae exposed to 0.1 micro L/mL of the effluent indicated that this is the highest nontoxic concentration for Drosophila. The stress gene assay in the reproductive organs of adult flies revealed hsp70 expression in the testis of male flies only. However, trypan blue dye exclusion tests in these tissues indicate tissue damage in the male accessory gland of adult flies, which was further confirmed by ultrastructural observations. In the present study we demonstrate the utility of transgenic Drosophila as an alternative animal model for evaluating hazardous effects of the effluent from the chrome plating industry and further reveal the cytoprotective role of hsp70 and its expression as an early marker in environmental risk assessment. PMID:14644668

  19. CHARACTERIZATION OF CHROMIUM-CONTAMINATED SOILS USING FIELD-PORTABLE X-RAY FLUORESCENCE

    EPA Science Inventory

    A detailed characterization of the underlying and adjacent soils near a chrome plating shop utilized field-portable X- ray fluorescence (XRF) as a screening tool. XRF permitted real-time acquisition of estimates for total metal content of soils. A trailer-mounted soil coring unit...

  20. Co-electrodeposition of hard Ni-W/diamond nanocomposite coatings

    PubMed Central

    Zhang, Xinyu; Qin, Jiaqian; Das, Malay Kumar; Hao, Ruru; Zhong, Hua; Thueploy, Adisak; Limpanart, Sarintorn; Boonyongmaneerat, Yuttanant; Ma, Mingzhen; Liu, Riping

    2016-01-01

    Electroplated hard chrome coating is widely used as a wear resistant coating to prolong the life of mechanical components. However, the electroplating process generates hexavalent chromium ion which is known carcinogen. Hence, there is a major effort throughout the electroplating industry to replace hard chrome coating. Composite coating has been identified as suitable materials for replacement of hard chrome coating, while deposition coating prepared using traditional co-deposition techniques have relatively low particles content, but the content of particles incorporated into a coating may fundamentally affect its properties. In the present work, Ni-W/diamond composite coatings were prepared by sediment co-electrodeposition from Ni-W plating bath, containing suspended diamond particles. This study indicates that higher diamond contents could be successfully co-deposited and uniformly distributed in the Ni-W alloy matrix. The maximum hardness of Ni-W/diamond composite coatings is found to be 2249 ± 23 Hv due to the highest diamond content of 64 wt.%. The hardness could be further enhanced up to 2647 ± 25 Hv with heat treatment at 873 K for 1 h in Ar gas, which is comparable to hard chrome coatings. Moreover, the addition of diamond particles could significantly enhance the wear resistance of the coatings. PMID:26924136

  1. [Evaluation of bond strength between low fusing porcelain with goldplated cobalt-chromium alloys].

    PubMed

    Guo, Jing; Zhu, Jia; Zhu, Hong-shui

    2014-02-01

    To evaluate the bond strength of Vita OMEGA 900 low fusing porcelain fused with the goldplated Wirobond cobalt-chrome metalt ceramic alloy. Low fusing porcelain was fused with the cobalt-chromium alloy strips(group A) and the goldplated cobalt-chromium alloy strips(group B) respectively according to ISO9693 (A:8,B:10). 8 specimens of each group were submitted to three point bending test. Two more test pieces fused with gold plated cobalt-chromium alloys were made (group B'). One test piece of both group B and group B' were observed under scanning electron microscope (SEM) randomly. The data was analyzed with SPSS 16.0 software package. The bond strength (MPa) of group A and group B was 29.92±4.28 and 28.20±5.21, respectively (P>0.05), both higher than 25 MPa required by ISO9693. SEM showed that Vita OMEGA 900 low fusing porcelain and the goldplated Wirobond cobalt-chrome metalt ceramic alloy combined together closely without cracks. Much gold was fused to the cobalt-chrome alloy surface of breaking porcelain specimen after testing. Vita OMEGA 900 low fusing porcelain can match with the goldplated Wirobond cobalt-chrome metalt ceramic alloy. Supported by Foundation of Education Department of Jiangxi Province (GJJ10367).

  2. Co-electrodeposition of hard Ni-W/diamond nanocomposite coatings.

    PubMed

    Zhang, Xinyu; Qin, Jiaqian; Das, Malay Kumar; Hao, Ruru; Zhong, Hua; Thueploy, Adisak; Limpanart, Sarintorn; Boonyongmaneerat, Yuttanant; Ma, Mingzhen; Liu, Riping

    2016-02-29

    Electroplated hard chrome coating is widely used as a wear resistant coating to prolong the life of mechanical components. However, the electroplating process generates hexavalent chromium ion which is known carcinogen. Hence, there is a major effort throughout the electroplating industry to replace hard chrome coating. Composite coating has been identified as suitable materials for replacement of hard chrome coating, while deposition coating prepared using traditional co-deposition techniques have relatively low particles content, but the content of particles incorporated into a coating may fundamentally affect its properties. In the present work, Ni-W/diamond composite coatings were prepared by sediment co-electrodeposition from Ni-W plating bath, containing suspended diamond particles. This study indicates that higher diamond contents could be successfully co-deposited and uniformly distributed in the Ni-W alloy matrix. The maximum hardness of Ni-W/diamond composite coatings is found to be 2249 ± 23 Hv due to the highest diamond content of 64 wt.%. The hardness could be further enhanced up to 2647 ± 25 Hv with heat treatment at 873 K for 1 h in Ar gas, which is comparable to hard chrome coatings. Moreover, the addition of diamond particles could significantly enhance the wear resistance of the coatings.

  3. Co-electrodeposition of hard Ni-W/diamond nanocomposite coatings

    NASA Astrophysics Data System (ADS)

    Zhang, Xinyu; Qin, Jiaqian; Das, Malay Kumar; Hao, Ruru; Zhong, Hua; Thueploy, Adisak; Limpanart, Sarintorn; Boonyongmaneerat, Yuttanant; Ma, Mingzhen; Liu, Riping

    2016-02-01

    Electroplated hard chrome coating is widely used as a wear resistant coating to prolong the life of mechanical components. However, the electroplating process generates hexavalent chromium ion which is known carcinogen. Hence, there is a major effort throughout the electroplating industry to replace hard chrome coating. Composite coating has been identified as suitable materials for replacement of hard chrome coating, while deposition coating prepared using traditional co-deposition techniques have relatively low particles content, but the content of particles incorporated into a coating may fundamentally affect its properties. In the present work, Ni-W/diamond composite coatings were prepared by sediment co-electrodeposition from Ni-W plating bath, containing suspended diamond particles. This study indicates that higher diamond contents could be successfully co-deposited and uniformly distributed in the Ni-W alloy matrix. The maximum hardness of Ni-W/diamond composite coatings is found to be 2249 ± 23 Hv due to the highest diamond content of 64 wt.%. The hardness could be further enhanced up to 2647 ± 25 Hv with heat treatment at 873 K for 1 h in Ar gas, which is comparable to hard chrome coatings. Moreover, the addition of diamond particles could significantly enhance the wear resistance of the coatings.

  4. Survey of coatings for solar collectors

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1975-01-01

    Optimum solar selective properties of black chrome require some tailoring of current and time for plating solution being used. Black zinc is produced from high zinc electroplate by subsequent conversion with chromate dip. Measurements have also been made of reflectance of previously known solar selective coatings of black copper and electroplated black nickel.

  5. IN-SITU TREATMENT OF CHROMIUM SOURCE AREA USING REDOX MANIPULATION

    EPA Science Inventory

    Sodium dithionite was used to treat a chromium source zone in soils beneath an old chrome plating shop. The sodium dithionite was injected as a buffered solution into the soils to transform the chromium from the oxidized (+6) state to the reduced (+3) state. Once reduced the chro...

  6. REDUCTIVE DETOXIFICATION AND IMMOBILIZATION OF CHROMATE PRESENT IN SOILS

    EPA Science Inventory

    Sodium dithionite was used to treat a chromium source zone in soils beneath an old chrome plating shop. The sodium dithionite was injected as a buffered solution into the soils to transform the chromium from the oxidized (+6) state to the reduced (+3) state. Once reduced the chro...

  7. IN-SITU REDUCTION OF CHROMIUM-CONTAMINATED GROUNDWATER, SOILS, AND SEDIMENTS BY SODIUM DITHIONITE

    EPA Science Inventory

    Laboratory studies were conducted to characterize the extent of chromium contamination in the groundwater and underlying soils and sediments of a chrome-plating shop at the USCG Support Center near Elizabeth City, NC. Most of the mobile Cr(VI) is present in the capillary zone ...

  8. IN-SITU REMEDIATION OF CHROMIUM-CONTAMINATED SOILS AND SEDIMENTS USING SODIUM DITHIONITE

    EPA Science Inventory

    Soil cores were collected from beneath an old chrome plating shop at the USCG Support Center near Elizabeth City, NC in order to determine the extent of chromium contamination in the soils and ground water. Selective extractions were used to assess the chemical speciation and di...

  9. TRANSPORT AND TRANSFORMATION OF HEXAVALENT CHROMIUM THROUGH SOILS AND INTO GROUND WATER

    EPA Science Inventory

    A detailed characterization of the underlying and adjacent soils of a chrome-plating shop was performed to provide information on the extent of soil and aquifer contamination at the site and on the potential for off-site migration and environmental impact. Intact, moist cores wer...

  10. PHYSICAL VAPOR DEPOSITION OF TANTALUM ON GUN BARREL STEEL (SYSTEMS ANLAYSIS BRANCH, SUSTAINABLE TECHNOLOGY DIVISION, NRMRL)

    EPA Science Inventory

    This project entails the development of an alternative technology for plating gun barrel steel to replace the process electroplating of chrome (Cr-electroplate) with physical vapor deposition of tantalum (Ta-PVD). Developed by Benet Laboratory at Watervliet Arsenal, this project'...

  11. IN-SITU REMEDIATION OF CHROMIUM-CONTAMINATED SOILS AND SEDIMENTS

    EPA Science Inventory

    The objectives of this study were to characterize the extent of total chromium and Cr(VI)contamination in the underlying soils and sediments of a chrome-plating shop at the USCG Support Center near Elizabeth City, NC and to evaluate the use of liquid reductants for in situ treatm...

  12. Detailed Analysis and Design Review of the MARK IX (Modified) Underwater Breathing Apparatus

    DTIC Science & Technology

    1969-07-30

    hard- chrome plated, and the purge-valve assembly and regulator piston . electroless-nickel plated. Manufacturing/Assembly Controls and Tests The control...high a flow through the orifice, peak pressures of 4500 psi have been applied repeatedly with- out failure or damage to any component. (7) Orifice...c) Proved In use. (d) "Functional" test by stpplkir. (5)J (e) Peak pressure of only 4500 jsi reached. (1) (f) Leak test at 1-1/2 •is. (g) Predive

  13. Hex-Chrome Free Hardware - BAE Experience

    DTIC Science & Technology

    2010-06-01

    plating, freedom from hydrogen embrittlement Cost is comparable to Type II chromate zinc • But much better corrosion performance Wide use by automotive...Fiat 9.57513/ Tipo IV • Ford S439 (WSS-M21P37-A1) • General Motors GM7114M, GMW3359 • Int’l Truck TMS-4518, Type I • ISO 10683 • JLG 4150701 • John...salt spray) to meet customer requirements (uses Geomet) • Fastener supplier provides similar dip-spin coatings • Cost virtually same as zinc plate • No

  14. SITE CHARACTERIZATION OF A CHROMIUM SOURCE AREA AT THE USGS SUPPORT CENTER, ELIZABETH CITY, NC

    EPA Science Inventory

    Chromic and sulfuric acid wastes had discharged through a hole in the concrete floor of a chrome-plating shop located within a hangar at the U.S. Coast Guard Support Center near Elizabeth City, North Carolina and infiltrated the soils and groundwater beneath the shop. Following i...

  15. 62P-165

    NASA Image and Video Library

    1962-10-18

    The Atlas-Agena B space Vehicle waits on the launch pad to launch the National Aeronautics and Space Administration’s Ranger V Spacecraft on a 66 – 62 hour journey to the moon. Ranger V is a 735-pound gold and chrome Plated payload designed to perform a series of complicated tasks, including taking television pictures of the lunar surface.

  16. Workers' understanding of chemical risks: electroplating case study

    PubMed Central

    Sadhra, S; Petts, J; McAlpine, S; Pattison, H; MacRae, S

    2002-01-01

    Background: There is limited research concerning how small companies in particular, respond to health and safety messages. Aims: To understand individuals' knowledge and beliefs about chemical risks and to compare these with those of experts. Methods: The use of chromic acid in particular, and also other chemicals associated with chrome plating were studied. All chromium plating firms were based in the West Midlands. The methodology involved initial face to face interviews (n = 21) with chromium platers, structured questionnaires (n = 84) to test the prevalence of beliefs identified in the interviews, an expert questionnaire, and a workshop to discuss findings. The responses of platers were compared with those of occupational health and safety experts. Results: Although chromium platers appeared to understand the short term adverse effects of the chemicals to which they are exposed, their understanding of long term, or chronic effects appeared to be incomplete. They had good knowledge of acute effects based primarily on experience. Platers were aware of the hazardous nature of the chemicals with which they work, but did not draw distinction between the terms "hazards" and "risks". They had difficulties articulating the effects of the chemicals and how exposure might occur; although it is inappropriate to equate this with lack of knowledge. A significant minority of platers displayed deficiencies in understanding key technical terms used in Safety Data Sheets. Conclusions: This study provides a method which can be used to gain some understanding of workers' knowledge and beliefs about risks that they are exposed to in the workplace. The study also identifies gaps between the platers' knowledge and beliefs and those of experts. New risk information needs to be designed which addresses the information needs of platers using language that they understand. PMID:12356930

  17. Indoor test for thermal performance evaluation of Lenox-Honeywell solar collector. [conducted using Marshall Space Flight Center Solar Simulator

    NASA Technical Reports Server (NTRS)

    Shih, K.

    1977-01-01

    The test procedures used and the test results obtained from an evaluation test program conducted on a double-covered liquid solar collector under simulated conditions are presented. The test article was a flat plate solar collector using liquid as the heat transfer medium. The absorber plate was steel with the copper tubes bonded on the upper surface. The plate was coated with black chrome with an absorptivity factor of .95 and emissivity factor of .12. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector.

  18. IN-SITU REDUCTION OF CHROMATE-CONTAMINATED SOILS AND SEDIMENTS BY SODIUM DITHIONITE: A FIELD-SCALE STUDY

    EPA Science Inventory

    A chrome-plating shop had been the source of discharges of acidic chromium wastes into the soils and groundwater beneath the shop at the USCG Support Center near Elizabeth City, NC. An initial characterization of the site was conducted in 1990 and 1991 to determine the extent of...

  19. Effects of chromium on the immune system.

    PubMed

    Shrivastava, Richa; Upreti, R K; Seth, P K; Chaturvedi, U C

    2002-09-06

    Chromium is a naturally occurring heavy metal found commonly in the environment in trivalent, Cr(III), and hexavalent, Cr(VI), forms. Cr(VI) compounds have been declared as a potent occupational carcinogen among workers in chrome plating, stainless steel, and pigment industries. The reduction of Cr(VI) to Cr(III) results in the formation of reactive intermediates that together with oxidative stress oxidative tissue damage and a cascade of cellular events including modulation of apoptosis regulatory gene p53, contribute to the cytotoxicity, genotoxicity and carcinogenicity of Cr(VI)-containing compounds. On the other hand, chromium is an essential nutrient required to promote the action of insulin in body tissues so that the body can use sugars, proteins and fats. Chromium is of significant importance in altering the immune response by immunostimulatory or immunosuppressive processes as shown by its effects on T and B lymphocytes, macrophages, cytokine production and the immune response that may induce hypersensitivity reactions. This review gives an overview of the effects of chromium on the immune system of the body. Copyright 2002 Federation of European Microbiological Societies

  20. Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE) Interim Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2015-01-01

    Test specimen configuration was provided by Parker Chomerics. The EMI gasket used in this project was Cho-Seal 6503E. Black oxide alloy steel socket head bolts were used to hold the plates together. Non-conductive spacers were used to control the amount of compression on the gaskets. The following test fixture specifications were provided by Parker Chomerics. The CHO-TP09 test plate sets selected for this project consist of two aluminum plates manufactured to the specifications detailed in CHO­-TP09. The first plate, referred to as the test frame, is illustrated in Figure 1. The test frame is designed with a cutout in the center and two alternating bolt patterns. One pattern is used to bolt the test frame to the corresponding test cover plate (Figure 2), forming a test plate set. The second pattern accepts the hardware used to mount the fully assembled test plate set to the main adapter plate (Figure 3).

  1. Engineering Design Handbook: Maintenance Engineering Techniques

    DTIC Science & Technology

    1975-06-30

    resistance and lustrous appearance. Relatively expensive. Spec- ify hard chrome plate for exceptionally hard abrasion-resistant surface . Has low...36 Bearing Seals 3-36 Derating 3-37 Lubrication 3-37 Fixed Joints 3-37 Self-adjusting Components ." 3-38 Corrosion Aspects 3-38 Material...Troubleshooting Considerations by Army Command Category •■■ Fixed Plant/Defense Communications and USASA Equipment Army Aircraft Automotive and

  2. 46 CFR 160.061-2 - Requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Leader, wire, 0.011-inch diameter, 27-pound test (with No. 3 snap on one end and No. 7 swivel on the other end) 6-inch length 2 ea. 6 Leader, wire, 0.016-inch diameter, 58-pound test (with No. 3 snap on... shank, blade length 23/16 inches, width 13/16 inch, weight 1/4 ounce, stainless steel or chrome plated...

  3. 46 CFR 160.061-2 - Requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Leader, wire, 0.011-inch diameter, 27-pound test (with No. 3 snap on one end and No. 7 swivel on the other end) 6-inch length 2 ea. 6 Leader, wire, 0.016-inch diameter, 58-pound test (with No. 3 snap on... shank, blade length 23/16 inches, width 13/16 inch, weight 1/4 ounce, stainless steel or chrome plated...

  4. THE APPLICATION OF IN SITU PERMEABLE REACTIVE (ZERO-VALENT IRON) BARRIER TECHNOLOGY FOR THE REMEDIATION OF CHROMATE-CONTAMINATED GROUNDWATER: A FIELD TEST

    EPA Science Inventory

    A small-scale field test was initiated in September 1994 to evaluate the in situ remediation of groundwater contaminated with chromate using a permeable reactive barrier composed of a mixture of zero-valent Fe, sand and aquifer sediment. The site used was an old chrome-plating f...

  5. Treatment of chrome plating wastewater (Cr+6) using activated alumina.

    PubMed

    Sarkar, Sudipta; Gupta, Anirban

    2003-01-01

    Suitability of activated alumina for removal of hexavalent chromium from electroplating wastewater has been investigated. Activated alumina exhibited good sorption capacity for hexavalent chromium and pH has no pronounced effect on the sorption capacity. Both batch and column adsorption studies have been carried out and an adsorption column design indicated reasonable depth of column for practical application.

  6. Experimental evaluation of a fixed collector employing vee-trough concentrator and vacuum tube receivers

    NASA Technical Reports Server (NTRS)

    Selcuk, M. K.

    1977-01-01

    A test bed for experimental evaluation of a fixed solar collector which combines an evacuated glass tube solar receiver with a flat plate/black chrome plated copper absorber and an asymmetric vee-trough concentrator was designed and constructed. Earlier predictions of thermal performance were compared with test data acquired for a bare vacuum tube receiver; and receiver tubes with Alzak aluminum, aluminized FEP Teflon film laminated sheet metal and second surface ordinary mirror reflectors. Test results and system economics as well as objectives of an ongoing program to obtain long-term performance data are discussed.

  7. Low Temperature Cure Powder Coatings

    DTIC Science & Technology

    2013-05-01

    operations Minimize worker exposure to VOCs, HAPs, and hexavalent chrome Passed objective AF Engr Qual Plan = Air Force Engineer Quality Plan MIL-PRF...Inconclusive • Inconclusive • Not applicable (N/A) • Passed criteria Reduction of hexavalent chromium use • Passed objective Reduction of hazardous...compliance. The implementation of the OSHA Final Rule designating the permissible exposure limit (PEL) for hexavalent chromium is a significant

  8. Corrosion Behavior of Sacrificial Coatings on Grade 10.9 Fasteners for Multimetal Armor Applications

    DTIC Science & Technology

    2013-08-01

    hexavalent chromium , immersion, magniplate, trivalent chromium (TCP), bolts nonchromate, hexavalent chrome, grade 10.9 fasteners, bolt-on armor...for Testing and Materials (ASTM) B633 (4) electroplated zinc with hexavalent chromium conversion coating 2. Trivalent Chromium Process (TCP): ASTM...B633 (4) electroplated zinc with trivalent chromium conversion coating 3. AlumiPlate: Process details, entire surface electroplated with aluminum (Al

  9. An Electron-Diffraction Examination of Cast-Iron Piston Rings from Single-Cylinder Aircraft-Engine Tests

    DTIC Science & Technology

    1945-02-01

    found t; a great extent on thn ueed cylinder barrel ( SAE 4140 steel) and to a lesser extent on the top ohrmne- plated ring of the aesembl.yafter it had...on the used cylinder barrel (W 4140 steel) used in the tests and, to a lesser extent, on the used top chrome-platedring of the piston assembly. The

  10. Chrome-Free Paint Primer for Zn/Ni Plated High-Strength Steel (Briefing Charts)

    DTIC Science & Technology

    2014-11-19

    restrictions on use of chromates and Cd  Strontium chromate sunset in EU - REACH: 2017  LHE ZnNi replacing LHE Cd in military and commercial...Interaction Plot for Corrosion score Data Means 10001001010.10.01 99 95 90 80 70 60 50 40 30 20 10 5 1 Corrosion score P e rc e n t 1 2 Metal Base Lognormal

  11. Mortality of tanners.

    PubMed Central

    Pippard, E C; Acheson, E D; Winter, P D

    1985-01-01

    The mortality of 833 male tannery workers known to have been employed in the industry in 1939 and who were followed up to the end of 1982 was studied. A total of 573 men had been employed in making leather tanned by vegetable extracts for soles and heels, and 260 men had used chrome tanning to make leather for the upper parts of shoes. No significant excesses of deaths were found for any of the common sites of cancer in either group of workers. One death from nasal cancer (0.21 expected) was reported among the men who worked with sole and heel leather. PMID:3978050

  12. A Miniature Stem Thermocouple Hygrometer 1

    PubMed Central

    Michel, Burlyn E.

    1977-01-01

    An unprotected chromel-constantan thermocouple was mounted in a cavity (4 × 2 × 1 mm) with rounded corners in a chrome-plated brass block (10 × 6 × 4 mm). When installed against a soybean (Glycine max [L.] Merr.) xylem face, sealed with caulking gum, and insulated with polyurethane foam and aluminum foil, even rapidly changing stem water potentials could be followed accurately. Temperature gradients can be a problem. PMID:16660155

  13. A Comparison of Gravimetric and Photometric Aerosol Samplers

    DTIC Science & Technology

    2009-03-24

    the potential to cause disease (Vincent, 2007; Meldrum , 1996; and ATSDR, 2001). f) Fog – discernible mist that floats in air and usually settles to...atomization, such as spraying or arising from acid baths in chrome plating. The droplets are homogenous with the parent material and range from xvi...Contaminant Control. Boston, Butterworth Publishers. Meldrum , M. (1996). Review of fibre toxicology. H.S.E. Report, London, UK, Health and Safety

  14. Improving global CD uniformity by optimizing post-exposure bake and develop sequences

    NASA Astrophysics Data System (ADS)

    Osborne, Stephen P.; Mueller, Mark; Lem, Homer; Reyland, David; Baik, KiHo

    2003-12-01

    Improvements in the final uniformity of masks can be shrouded by error contributions from many sources. The final Global CD Uniformity (GCDU) of a mask is degraded by individual contributions of the writing tool, the Post Applied Bake (PAB), the Post Exposure Bake (PEB), the Develop sequence and the Etch step. Final global uniformity will improve by isolating and minimizing the variability of the PEB and Develop. We achieved this de-coupling of the PEB and Develop process from the whole process stream by using "dark loss" which is the loss of unexposed resist during the develop process. We confirmed a correspondence between Angstroms of dark loss and nanometer sized deviations in the chrome CD. A plate with a distinctive dark loss pattern was related to a nearly identical pattern in the chrome CD. This pattern was verified to have originated during the PEB process and displayed a [Δ(Final CD)/Δ(Dark Loss)] ratio of 6 for TOK REAP200 resist. Previous papers have reported a sensitive linkage between Angstroms of dark loss and nanometers in the final uniformity of the written plate. These initial studies reported using this method to improve the PAB of resists for greater uniformity of sensitivity and contrast. Similarly, this paper demonstrates an outstanding optimization of PEB and Develop processes.

  15. HVOF repair of steering rams for the USS Saipan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dwyer, A.L.; Jones, S.A.; Wykle, R.J.

    1995-12-31

    The steering rams aboard the USS Saipan (LHA-2) were badly corroded after 18 years of service. These rams are hydraulically operated and change the angle of the ship`s rudder. This corrosion allowed excessive leaking of hydraulic fluid into the machinery space. Permanent repairs were required as the ship has more than 20 years of service life remaining. Two methods of repair were considered, chrome plating and a HVOF applied coating. The size, 13 in. diameter and 15 ft in length, posed a significant problem for either process. The cost of the repair was similar but the time for completion wasmore » better with the HVOF process since chrome plating would have to be accomplished off yard. The HVOF process was not available within the shipyard at the time and the process and material to be used had not been approved. Extensive testing was required to get approval to proceed, a facility to accomplish the work had to be built, and the operators and HVOF procedure had to be qualified. After completion of spraying, single point machining and honing was used to obtain the required surface finish. This was the largest single HVOF coating applied by the Navy and great interest to all concerned.« less

  16. Characterization of emission factors related to source activity for trichloroethylene degreasing and chrome plating processes.

    PubMed

    Wadden, R A; Hawkins, J L; Scheff, P A; Franke, J E

    1991-09-01

    A study at an automotive parts fabrication plant evaluated four metal surface treatment processes during production conditions. The evaluation provides examples of how to estimate process emission factors from activity and air concentration data. The processes were open tank and enclosed tank degreasing with trichloroethylene (TCE), chromium conversion coating, and chromium electroplating. Area concentrations of TCE and chromium (Cr) were monitored for 1-hr periods at three distances from each process. Source activities at each process were recorded during each sampling interval. Emission rates were determined by applying appropriate mass balance models to the concentration patterns around each source. The emission factors obtained from regression analysis of the emission rate and activity data were 16.9 g TCE/basket of parts for the open-top degreaser; 1.0 g TCE/1000 parts for the enclosed degreaser; 1.48-1.64 mg Cr/1000 parts processed in the hot CrO3/HNO3 tank for the chrome conversion coating; and 5.35-9.17 mg Cr/rack of parts for chrome electroplating. The factors were also used to determine the efficiency of collection for the local exhaust systems serving each process. Although the number of observations were limited, these factors may be useful for providing initial estimates of emissions from similar processes in other settings.

  17. The Labour Welfare Fund Laws (Amendment) Act, 1987 (No. 15 of 1987), 22 May 1987.

    PubMed

    1987-01-01

    This Act authorizes funds constituted under the Mica Mines Labour Welfare Fund Act, 1946, the Limestone and Dolomite Mines Labour Welfare Fund Act, 1972, the Iron Ore Mines, Manganese Ore Mines and Chrome Mines Labour Welfare Fund Act, 1976, and the Beedi Workers Welfare Fund Act, 1976, to be applied for the provision of family welfare, including family planning education and services. full text

  18. Navy Successes and Challenges in Cr6+ Minimization

    DTIC Science & Technology

    2011-05-12

    Authorization to Use Hexavalent Chromium. YES NO • Approval of alternatives by W/S PM and Corrosion SME designee. • Change technical/maintenance...Inorganic Coatings and Processes – Alternatives authorized for • Aluminum and magnesium anodizing • Hard Chrome Plating • Type II, Class 1A conversion...savings due to use of aluminum cathodes – Allows for consolidation of anodizing processes – Elimination of Hexavalent Chromium 80% 5% 14% 1% Type II

  19. Validation of HVOF Thermal Spray Coatings as a Replacement for Hard Chrome Plating on Hydraulic/Pneumatic Actuators

    DTIC Science & Technology

    2007-12-01

    Projects Agency (DARPA). The program evaluated HVOF, physical vapor deposition (PVD) and laser cladding , and concluded that HVOF was the best overall...components such as titanium flap tracks. 5 2.0 TECHNOLOGY DESCRIPTION 2.1 TECHNOLOGY DEVELOPMENT AND APPLICATION Technology background and...theory of operation: High-velocity oxygen-fuel (HVOF) is a standard commercial thermal spray process in which a powder of the material to be sprayed

  20. Implementing New Non-Chromate Coatings Systems (Briefing Charts)

    DTIC Science & Technology

    2011-02-09

    Initiate Cr6+ authorization process for continued Cr6+ use using the form, Authorization to Use Hexavalent Chromium. YES NO • Approval of...Aluminum and magnesium anodizing • Hard Chrome Plating • Type II conversion coating on aluminum alloys under chromated primer • Type II conversion coating...Elimination of Hexavalent Chromium 80% 5% 14% 1% Type II Type III Type IC Type IC Fatigue Critical 50% 50% Type II Type IC FRC-SE (JAX) Fully Integrated FRC

  1. Investigation of Plasma Spray Coatings as an Alternative to Hard Chrome Plating on Internal Surfaces

    DTIC Science & Technology

    2006-06-20

    specimens, typically 3 specimens at 5 stress levels, although stresses were chosen to obtain a full curve, with runout defined as 107 cycles. Maximum...measured using the ASTM G-65 method of a rubber wheel with dry sand rubbing against the substrate (see Figure 4-27). 100 120 140 160 180 200 220 240...different finishing methods. Silicon carbide, aluminum oxide and diamond grinding wheels were tested for the finishing trials. It was determined by

  2. Chromium-Makes stainless steel stainless

    USGS Publications Warehouse

    Kropschot, S.J.; Doebrich, Jeff

    2010-01-01

    Chromium, a steely-gray, lustrous, hard metal that takes a high polish and has a high melting point, is a silvery white, hard, and bright metal plating on steel and other material. Commonly known as chrome, it is one of the most important and indispensable industrial metals because of its hardness and resistance to corrosion. But it is used for more than the production of stainless steel and nonferrous alloys; it is also used to create pigments and chemicals used to process leather.

  3. The dark side of sniffing: paint colour affects intoxication experiences among adolescent inhalant users.

    PubMed

    Takagi, Michael J; Yücel, Murat; Lubman, Dan I

    2010-07-01

    Inhalant abuse among adolescents is a significant health concern in many countries; however, limited research has explored whether the intoxication experience differs between commonly used inhalants. The aim of the present study was to examine how exposure to different types of paints (chrome vs. non-chrome) were experienced by adolescent users. Sixteen adolescent (aged 15-19 years) regular inhalant users completed a semistructured questionnaire enquiring about their inhalant use. Participants were divided into two groups based on paint colour preference [chrome paints (n = 10) and non-chrome paints (n = 6)] and were compared using appropriate statistical tests. Relative to non-chrome users, the chrome-using group were more likely to report deliberately inhaling to experience altered perceptions (such as visual and auditory hallucinations). In addition, a significantly greater proportion of chrome users reported that the perceptual alterations they experienced after sniffing paint differed between paint colours, with chrome colours being associated with more vivid hallucinations. While both chrome and non-chrome users reported a comparable level of pleasure from paint sniffing, chrome paint users were more likely to be motivated by the potential to hallucinate. Our findings suggest that the type of inhalant used is an important consideration that may have relevance to clinical treatment.

  4. Occupational exposure to hexavalent chromium and cancers of the gastrointestinal tract: a meta-analysis.

    PubMed

    Gatto, Nicole M; Kelsh, Michael A; Mai, Diem Ha; Suh, Mina; Proctor, Deborah M

    2010-08-01

    We conducted a systematic literature review and meta-analysis of oral cavity, esophageal, stomach, small intestine, colon, and rectal cancers among workers occupationally exposed to Cr(VI). Using PubMed, studies published from 1950 to 2009 evaluating the relationship between Cr(VI) exposure and GI cancers were identified. Measures of effect and variability were extracted from 32 studies meeting specific inclusion criteria, and meta-analysis summary relative risk measures were calculated using random effects models and inverse variance weighting methods. Meta-standardized mortality ratios (SMRs) were, for cancer of the: oral cavity [1.02 (95% CI=0.77-1.34)]; esophagus [1.17 (95% CI=0.90-1.51)]; stomach [1.09 (95% CI=0.93-1.28)]; colon [0.89 (95% CI=0.70-1.12)]; and rectum [1.17 (95% CI=0.98-1.39)]. Analyses of more highly exposed subgroups included in the studies or subgroups based on geographic region or by industry with recognized Cr(VI) exposures (welding, chrome plating, chromate production, and pigment production) did not result in elevated meta-SMRs except for esophageal cancer among US cohorts [meta-SMR=1.49 (95% CI=1.06-2.09)]. However, that finding was based on a subgroup of only four studies, one of which was a PMR study. Potential confounding by socioeconomic status (SES), diet and/or smoking, or limitations due to the healthy-worker effect (HWE) were evaluated, and while smoking, diet and SES may be important factors that may have upwardly biased the meta-SMRs, HWE is not likely to have significantly affected the summary results. None of three studies reporting small intestine cancers observed a statistically significant increased risk. These meta-analyses and literature review indicate that Cr(VI)-exposed workers are not at a greater risk of GI cancers than the general population.

  5. ALTERNATIVE TO CHROME ETCHING PROCESSES FOR METALS

    EPA Science Inventory

    Several industries, including the National Center for Manufacturing Science have initiated programs for chrome abatement. The programs, however, generally focus on chrome reduction by use of existing technologies and do not address the elimination of chrome in pretreatment proces...

  6. Investigation of Plasma Spray Coatings as an Alternative to Hard Chrome Plating on Internal Surfaces

    DTIC Science & Technology

    2006-09-14

    low fracture strength, making it prone to cracking. It may be the best option for utility actuators that experience side loads or excessive ID wear...material than WC-12Co, but had the lowest porosity of the plasma spray coatings in initial process development tests, as well as higher fracture ...grind Adhesion Pull 0.013-0.015" 0.008-0.010" 8 microinch Residual stress Almen 0.013-0.015" no grind Strain-to- fracture 4-pt Almen 0.013-0.015

  7. Calibration of Breech Erosion Gage for 5.56mm Chrome-Plated Bores

    DTIC Science & Technology

    1975-12-01

    34 tft.. CantoiIlate Olft.) Ill TEUIy CLASS. (of ffile .oepot) Unclassified ISO . DECL ASSi VIC ATION’DOW94GRADING 16. DISTRIOUTION STATEMENT (of Wit9...6.3 8.9 13.4 7.6 7.3 6.3 6.2 7.1 26000 16.1 9.1 10.9 13.9 8.9 6.4 6.3 3.1 4.9 27000 12.4 8.4 11.2 13.1 8.3 6.5 7.3 3.4 4.3 28000 12.1 6.9 19.3 11.4

  8. Green route for the utilization of chrome shavings (chromium-containing solid waste) in tanning industry.

    PubMed

    Rao, Jonnalagadda Raghava; Thanikaivelan, Palanisamy; Sreeram, Kalarical Janardhanan; Nair, Balachandran Unni

    2002-03-15

    Chromium-containing wastes from various industrial sectors are under critical review. Leather processing is one such industrial activity that generates chromium-bearing wastes in different forms. One of them is chrome shavings, and this contributes to an extent of 10% of the quantum of raw skins/hides processed, amounting to 0.8 million ton globally. In this study, the high protein content of chrome shavings has been utilized for reduction of chromium(VI) in the preparation of chrome tanning agent. This approach has been exploited for the development of two products: one with chrome shavings alone as reducing agent and the other with equal proportion of chrome shavings and molasses. The developed products exhibit more masking due to the formation of intermediate organic oligopeptides. This has been corroborated through the spectral, hydrolysis, and species-wise distribution studies. The formation of these organic masking agents helps in chrome tanning by shifting the precipitation point of chromium to relatively higher pH levels. Hence, the developed products find use as chrome tanning agents for leather processing, thus providing a means for better utilization of chrome shaving wastes.

  9. Active heat exchange system development for latent heat thermal energy storage

    NASA Technical Reports Server (NTRS)

    Lefrois, R. T.

    1980-01-01

    Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion Phase Change Materials (PCM's) in the temperature range of 250 C to 350 C for solar and conventional power plant applications. Over 24 heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were chosen for small-scale experimentation: a coated tube and shell that exchanger, and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over fifty inorganic salt mixtures investigated. Preliminary experiments with various tube coatings indicated that a nickel or chrome plating of Teflon or Ryton coating had promise of being successful. An electroless nickel plating was selected for further testing. A series of tests with nickel-plated heat transfer tubes showed that the solidifying sodium nitrate adhered to the tubes and the experiment failed to meet the required discharge heat transfer rate of 10 kW(t). Testing of the reflux boiler is under way.

  10. Active heat exchange system development for latent heat thermal energy storage

    NASA Astrophysics Data System (ADS)

    Lefrois, R. T.

    1980-03-01

    Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion Phase Change Materials (PCM's) in the temperature range of 250 C to 350 C for solar and conventional power plant applications. Over 24 heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were chosen for small-scale experimentation: a coated tube and shell that exchanger, and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over fifty inorganic salt mixtures investigated. Preliminary experiments with various tube coatings indicated that a nickel or chrome plating of Teflon or Ryton coating had promise of being successful. An electroless nickel plating was selected for further testing. A series of tests with nickel-plated heat transfer tubes showed that the solidifying sodium nitrate adhered to the tubes and the experiment failed to meet the required discharge heat transfer rate of 10 kW(t). Testing of the reflux boiler is under way.

  11. Lung cancer risk in the electroplating industry in Lombardy, Italy, using the Italian occupational cancer monitoring (OCCAM) information system.

    PubMed

    Panizza, Celestino; Bai, Edoardo; Oddone, Enrico; Scaburri, Alessandra; Massari, Stefania; Modonesi, Carlo; Contiero, Paolo; Marinaccio, Alessandro; Crosignani, Paolo

    2012-01-01

    Occupational Cancer Monitoring (OCCAM) is an Italian organization that monitors occupational cancers, by area and industrial sector, by retrieving cases and employment history from official databases. OCCAM previously estimated a relative risk (RR) of lung cancer of about 1.32 among "metal treatment" workers in Lombardy, northern Italy, potentially exposed to chrome and nickel. In the present study, lung cancer risk was estimated among electroplating workers only. Lombardy electroplating companies were identified from descriptions in Social Security files. Lung cancer risk was evaluated from 2001 to 2008 incident cases identified from hospital discharge records. The RR for lung cancer among electroplating workers was 2.03 (90% CI 1.33-3.10, 18 cases) for men; 3.00 (90% CI 1.38-9.03, 4 cases) for women. Electroplaters had higher risks than "metal treatment" workers. Although the risks were due to past exposure, case histories and recent acute effects indicate a present carcinogenic hazard in some Lombardy electroplating factories. Copyright © 2011 Wiley Periodicals, Inc.

  12. Microbial Influenced Corrosion (MIC) Study

    DTIC Science & Technology

    2012-05-23

    DAY 28 Chrome  Conversion Coating  Coupon Type: A    Alodine 1200 (Henkel)  Non‐ Chrome  Treatment  Coupon Type: E    Prekote® (Pantheon Chemical... Chrome  Conversion Coating +  Chrome  Primer  Coupon Type: B    Alodine 1200 (Henkel)  MIL PRF 23377H TY 1 CL 2 (Deft‐ ‐ ,    ,       ‐   02Y040A)  Non... Chrome  Treatment + Non‐ Chrome  Primer  Coupon Type: F BUSINESS SENSITIVE 23         Prekote® (Pantheon Chemical)  MIL‐PRF‐23377H, TY 1, CL N (Deft

  13. Design Architecture of field-effect transistor with back gate electrode for biosensor application

    NASA Astrophysics Data System (ADS)

    Fathil, M. F. M.; Arshad, M. K. Md.; Hashim, U.; Ruslinda, A. R.; Gopinath, Subash C. B.; M. Nuzaihan M., N.; Ayub, R. M.; Adzhri, R.; Zaki, M.; Azman, A. H.

    2016-07-01

    This paper presents the preparation method of photolithography chrome mask design used in fabrication process of field-effect transistor with back gate biasing based biosensor. Initially, the chrome masks are designed by studying the process flow of the biosensor fabrication, followed by drawing of the actual chrome mask using the AutoCAD software. The overall width and length of the device is optimized at 16 mm and 16 mm, respectively. Fabrication processes of the biosensor required five chrome masks, which included source and drain formation mask, the back gate area formation mask, electrode formation mask, front gate area formation mask, and passivation area formation mask. The complete chrome masks design will be sent for chrome mask fabrication and for future use in biosensor fabrication.

  14. Solar-collector materials exposure to the IPH site environment. Task 5.0

    NASA Astrophysics Data System (ADS)

    Morris, V. L.

    1982-07-01

    An environmental exposure test was conducted at a site which utilizes solar energy for enhanced oil recovery procedures. Two types of reflector materials were evaluated for survivability in this environment: second surface silvered glass and aluminized acrylic (FEK-244) on an aluminum substrate. Black chrome absorber material and low iron float glass were evaluated for thermal, photochemical and environmental degradation. The reflector specimens were monitored for decreases in specular and hemispherical reflectance due to soil buildup. The absorber material is evaluated for changes in solar absorptivity and emissivity and the glass cover plates is evaluated for changes in transmissivity.

  15. Electrodeposition of Nanocrystalline Cobalt Phosphorous Coatings as a Hard Chrome Alternative

    DTIC Science & Technology

    2014-11-01

    1 ASETSDefense 2014 Electrodeposition of Nanocrystalline Cobalt Phosphorous Coatings as a Hard Chrome Alternative Ruben A. Prado, CEF...COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE Electrodeposition of Nanocrystalline Cobalt Phosphorous Coatings as a Hard Chrome Alternative...coatings as a Hard Chrome (EHC) electroplating alternative for DoD manufacturing and repair. – Fully define deposition parameters and properties

  16. Ultrasound assisted chrome tanning: Towards a clean leather production technology.

    PubMed

    Mengistie, Embialle; Smets, Ilse; Van Gerven, Tom

    2016-09-01

    Nowadays, there is a growing demand for a cleaner, but still effective alternative for production processes like in the leather industry. Ultrasound (US) assisted processing of leather might be promising in this sense. In the present paper, the use of US in the conventional chrome tanning process has been studied at different pH, temperature, tanning time, chrome dose and US exposure time by exposing the skin before tanning and during tanning operation. Both prior exposure of the skin to US and US during tanning improves the chrome uptake and reduces the shrinkage significantly. Prior exposure of the skin to US increase the chrome uptake by 13.8% or reduces the chrome dose from 8% to 5% (% based on skin weight) and shorten the process time by half while US during tanning increases the chrome uptake by 28.5% or reduces the chrome dose from 8% to 4% (half) and the tanning time to one third compared to the control without US. Concomitantly, the resulting leather quality (measured as skin shrinkage) improved from 5.2% to 3.2% shrinkage in the skin exposed to US prior tanning and to 1.3% in the skin exposed to US during the tanning experiment. This study confirms that US chrome tanning is an effective and eco-friendly tanning process which can produce a better quality leather product in a shorter process time with a lower chromium dose. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. In the year 2525, if x ray is still alive, if lithography can survive, they may find...

    NASA Astrophysics Data System (ADS)

    Nistler, John L.; Michael, Mark; Hause, Fred N.; Edwards, Richard D.

    1998-12-01

    Data and discussions will be presented on the NTRM, National Technology Roadmap, for reticles based on a Process Integration perception. Specifically two layers are considered for this paper, the gate layer which is primarily a chrome geometry mask with a lot of open glass and a local interconnect layer which is primarily a chrome plate using clear geometries. Information from other sources is used where appropriate and actual in-house data is used to illustrate specific points. Realizing that demands from different customers for specific types of features tend to drive specific mask makers and their decisions on equipment purchases and processes. We attempt to help predict where Integration approaches have either caused a lag in technology pushes or have actually speeded up certain requirements. Discussions of integration requirements, which tend to push maskmakers, will be presented. Along with typical design approaches in OPC and PSM which either will push technology or actually slow down the trend towards smaller geometries. In addition, data will be presented showing how specific stepper characteristics may actually drive the customer's criteria, thus changing the requirements from customer to customer.

  18. AMCOM Hexavalent Chrome Free Initiatives

    DTIC Science & Technology

    2010-12-01

    AMCOM Hexavalent Chrome Free Initiatives 1 December 2010 SERDP-ESTCP Symposium Washington DC Mark Feathers AMCOM G-4 Environmental Division... Hexavalent Chrome Free Initiatives 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f...system environmental life cycle sustainability. G-4 is actively engaged in initiatives to reduce the use of hexavalent chrome used in materials and

  19. Microstructure and optical properties of black chrome befor and after exposure to high temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lampert, C.M.; Washburn, J.

    1979-01-01

    the chemical and microstructural stability of the CHROM-ONYX type of black chrome solar coating was investigated at different temperatures and atmospheres. This was done to give a better understanding of the mechanism of solar energy selectivity and its variability when subjected to short term heat treatments. The as-plated structure was found to consist of a suspension of metallic chromium particles within the size range of 100A in a amorphous oxide matrix. this assembly was in turn formed into larger particles within the size range of 0.05 to 0.30 microns. Short term high temperature heat treatments were used to simulate stagnationmore » conditions. Samples were annealed in both air and vacuum, which resulted in similar characteristics. Annealing in air appeared to mildly accelerate optical degradation at high temperatures. For short term heat treatments below 300/sup 0/C the reflective and microstructural properties appeared to be unchanged. By in situ vacuum annealing of the coating above 400/sup 0/C microscrystalline Cr/sub 2/O/sub 3/ was identified. By observation of diffraction patterns it was concluded that a-Cr/sub 2/O/sub 3/ was transformed into crystalline Cr/sub 2/O/sub 3/. The Cr/sub 2/O/sub 3/ phase continued to grow at higher temperatures at the expense of chromium content. At temperatures above 500/sup 0/C in vacuum, a new phase identified as Cr/sub 3/O/sub 4/ formed. It was found that black chrome failed optically between 500 to 600/sup 0/C for 1 hour heat treatments in both air and vacuum; also the coating heated in air failed mechanically by peeling at 600/sup 0/C.« less

  20. Microstructure and optical properties of black chrome before and after exposure to high temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lampert, C.M.; Washburn, J.

    1979-01-01

    The chemical and microstructural stability of the CHROM-ONYX type of black chrome solar coating was investigated at different temperatures and atmospheres. This was done to give a better understanding of the mechanism of solar energy selectivity and its variability when subjected to short term heat treatments. The as-plated structure was found to consist of a suspension of metallic chromium particles within the size range of 100A in an amorphous oxide matrix. This assembly was in turn formed into larger particles within the size range of 0.05-0.30 microns. Short term high temperature heat treatments were used to simulate stagnation conditions. Samplesmore » were annealed in both air and vacuum, which resulted in similar characteristics. Annealing in air appeared to mildly accelerate optical degradation at high temperatures. For short term heat treatments below 300/sup 0/C the reflective and microstructural properties appeared to be unchanged. By in situ vacuum annealing of the coating above 400/sup 0/C microcrystalline Cr/sub 2/O/sub 3/ was identified. By observation of diffraction patterns it was concluded that a-Cr/sub 2/O/sub 3/ was transformed into crystalline Cr/sub 2/O/sub 3/. The Cr/sub 2/O/sub 3/ phase continued to grow at higher temperatures at the expense of chromium content. At temperatures above 500/sup 0/C in vacuum, a new phase identified as NiCr/sub 2/O/sub 4/ formed. It was found that black chrome failed optically between 500-600/sup 0/C for 1 hour heat treatments in both air and vacuum; also the coating heated in air failed mechanically by peeling at 600/sup 0/C.« less

  1. Spectral reflectance properties of black chrome for use as a solar selective coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1974-01-01

    The NASA-Lewis Research Center has determined that a widely available commercially electroplated decorative finish known as black chrome has desirable solar selective properties. Black chrome electroplated coating has high absorbtance in the solar spectrum and low emissivity in the 250 F blackbody thermal spectrum. The spectral reflectance properties of a commercially prepared black chrome on steel have been measured. Values are presented for reflectance of the black chrome, and compared with the reflectance of black paint and with two available samples of black nickel which had been prepared for solar selective properties. The reflectance of black chrome, of the two black nickels, and of black paint integrated over the solar spectrum for air mass 2 were 0.132, 0.123, 0.133, and 0.033, respectively. The reflectance of the black chrome, two black nickels, and of the black paint integrated over the blackbody spectrum for 250 F from 3 to 15 microns are 0.912, 0.934, 0.891, and 0.033, respectively. These reflectance measurements indicate absorptivity-to-emissivity values of 9.8, 13.8, 8.0, and 1.00, respectively.

  2. A spectroscopic study for understanding the speciation of Cr on palm shell based adsorbents and their application for the remediation of chrome plating effluents.

    PubMed

    Kushwaha, Shilpi; Sreedhar, B; Sudhakar, Padmaja P

    2012-07-01

    Palm shell based adsorbents prepared under five different thermochemical conditions have been shown to be quite effective for removal of chromium (III and VI) from aqueous solutions. X-ray photoelectron spectroscopy (XPS) and Fourier Transform Infrared Spectroscopy (FT-IR) have been used to determine information about the speciation and binding of chromium on the adsorbents under study. X-ray photoelectron spectroscopy (XPS) studies indicate that oxidation of lignin moieties takes place concurrently to Cr(VI) reduction and leads to the formation of hydroxyl and carboxyl functions. The maximum adsorption capacity for hexavalent chromium was found to be about 313 mg/g in an acidic medium using PAPSP. This is comparable to other natural substrates and ordinary adsorbents. The efficacy of the adsorbents under study to remove chromium from plating waste water has been demonstrated. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Qualification and Flight Test of Non-Chrome Primers for C-130 Aircraft

    DTIC Science & Technology

    2011-08-17

    system  Significant hexavalent chrome reduction in finish system  Potential exposure level of spray applied chromated conversion coating not as...Lockheed Martin Aeronautics Company Qualification and Flight Test of Non- Chrome Primers for C-130 Aircraft Scott Jones Lockheed Martin...00-2011 to 00-00-2011 4. TITLE AND SUBTITLE Qualification and Flight Test of Non- Chrome Primers for C-130 Aircraft 5a. CONTRACT NUMBER 5b. GRANT

  4. Structure of a black chrome solar selective surface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lampert, C.M.

    1978-07-01

    The structure of ''CHROM-ONYX'' type of black chrome/metal selective absorber was studied to gain a better understanding of its influence upon the mechanism of wavelength selectivity. Spectral reflectance measurements were performed on seven samples. The best selectivity was found by these measurements to be 0.7 micron of black chrome on nickel and 1.0 micron of black chrome on copper. Both scanning and transmission electron microscopy were employed to study microstructure and chemical composition. As a result of the combined studies, some effects of black chrome thickness and the metallic substrate were determined. It was found that black chrome consisted ofmore » a very fine metallic distribution of particles of chromium, possibly suspended within a matrix of an oxide of chromium. This combination was, in turn, agglomerated into larger particles within the 0.05 to 0.3 micron size range. These larger particles formed a network which constituted the surface coating.« less

  5. Design architecture of double spiral interdigitated electrode with back gate electrode for biosensor application

    NASA Astrophysics Data System (ADS)

    Fathil, M. F. M.; Arshad, M. K. Md.; Hashim, U.; Ruslinda, A. R.; Gopinath, Subash C. B.; M. Nuzaihan M., N.; Ayub, R. M.; Adzhri, R.; Zaki, M.; Azman, A. H.

    2016-07-01

    This paper presents the preparation method of photolithography chrome mask design used in fabrication process of double spiral interdigitated electrode with back gate biasing based biosensor. By learning the fabrication process flow of the biosensor, the chrome masks are designed through drawing using the AutoCAD software. The overall width and length of the device is optimized at 7.0 mm and 10.0 mm, respectively. Fabrication processes of the biosensor required three chrome masks, which included back gate opening, spiral IDE formation, and passivation area formation. The complete chrome masks design will be sent for chrome mask fabrication and for future use in biosensor fabrication.

  6. [A case of chrome asthma induced by exposure to the stone cutter dust].

    PubMed

    Onizuka, Reiko; Tanabe, Kimiko; Nakayama, Yoshihisa; Fukuchi, Tetsuroh; Nakata, Kazunori; Hiki, Toshinobu

    2006-12-01

    The case of a forty-six year old, male patient with asthma caused by exposure to dust containing chrome is presented. When the patient was nineteen years old, he started working as a stonemason in a factory. He cut and ground stone with a stone-cutter to make statues and tombstones. Three years after staring to work, contact dermatitis was observed on his arms and hands. Within six years of work, he suffered from chronic coughing. After eight years, he experienced bronchial asthma attacks with wheezing and dyspnea. He had been exposed to dust for eight years before developing asthma. The symptoms increased gradually. He fell into severe asthma attacks causing unconsciousness and dyspnea. Several common therapies were not effective. The characteristics of his clinical course and occupational history suggested that the asthma must be caused by exposure to dust containing metal generated in the factory. Skin Patch Tests (SPT) were performed for cobalt, copper, iron, chrome, tin, and manganese salt. The result of the SPT indicated a strong positive result for potassium dichromate and positive for chromium sulfate, but did not show any indications in the control or for other metallic salt. Fluorescent X-ray analysis detected that chrome was present in the powder dust under the stone-cutter machine. However, the fluorescent X-ray analysis did not detect chrome in the stone materials. It was suggested that chrome must be contained in the metal dust generated from the steel cutter used to cut off and grind the stone. The metal component in the used cutter edge and the unused cutter edge were analyzed with electro-probe microanalyzer (EPMA). The result revealed that chrome was contained in the used, dull cutter edge and not in the new sharp cutter edge. Thus, the patient had been exposed to the dust containing chrome generated from part of the stainless steel of cutter. He had sensitized to chrome and this had caused the occupational chrome-asthma.

  7. [Nose disease caused by occupational exposure to chromium in the electroplating industry: cytomorphological aspects].

    PubMed

    Bolla, I; Gariboldi, L M; Gabrielli, M; Baldo, D; Romanelli, A; Tuberti, E; Magnani, F

    1990-01-01

    Twenty-six workers were studied (9 chrome-platers exposed to chromium dioxide and 17 workers exposed to metallic chromium dust) in order to investigate the macroscopic and cytological changes of the nasal mucosa due to exposure to water-soluble hexavalent chromium or to metallic chromium dust in the electroplating industry and the role of different valencies in the onset of nasal disease. Experimental and epidemiological data have shown that hexavalent chromium, which has strong oxidative power, induces more noticeable toxic effects on tissues and mucous membranes than other compounds. The correlation between the degree of local toxic effects and the chemical state of chromium was demonstrated in both the macro- and the microscopic investigations and in particular in the cytological examinations: cases of atypia were found only in workers exposed to hexavalent chromium. Evidence of atypia raises the question of whether hexavalent chromium may act as a carcinogenic agent on the rhinosinusal mucosa. For this reason, the introduction of cytological nasal examination in health surveillance programmes for this category of workers acquires considerable importance. Sample collection from the nasal mucosa by brushing is the method of choice since it is simple, non-invasive and gives good diagnostic results.

  8. Review of occupational epidemiology of chromium chemicals and respiratory cancer.

    PubMed

    Hayes, R B

    1988-06-01

    Several epidemiologic studies have investigated the association between cancer risk and employment in chromium producing and using industries. Strong and consistent associations have been found between employment in the primary chemical producing industry and the risk for respiratory cancer. Workers employed in chromate pigment production and possibly spray painters of chromate pigment paints appear to be at excess risk of respiratory cancer. Chrome platers may also be at excess risk, although the evidence is limited. A few studies indicate that chromium alloy welding may also be an exposure source of concern. Some studies of ferrochromium alloy workers have shown an excess risk for respiratory cancer, although the risk may in part be due to concomitant exposures. The evidence indicates that the hexavalent form of chromium is the primary agent of chromium carcinogenesis. Solubility and other characteristics of chromium compounds may also play a role in determining risk.

  9. Spectral reflectance properties of black chrome for use as a solar selective coating

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1974-01-01

    The NASA-Lewis Research Center has determined that a widely available commercially electroplated decorative finish known as black chrome has desirable solar selective properties. The spectral reflectance properties of a commercially prepared black chrome on steel were measured. Values are presented for reflectance of the black chrome, and compared with the reflectance of black paint (Nextel) and with two available samples of black nickel which had been prepared for solar selective properties. The reflectance of black chrome, of the two black nickels, and of black paint integrated over the solar spectrum for air mass 2 were 0.132, 0.123, 0.133, and 0.033, respectively. The reflectance of the black chrome, two black nickels, and of the black paint integrated over the blackbody spectrum for 250 F from 3 to 15 microns are 0.912, 0.934, 0.891, and 0.033, respectively. These reflectance measurements indicate absorptivity-to-emissivity values of 9.8, 13.8, 8.0, and 1.00, respectively.

  10. Microstructure of a black chrome solar selective absorber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lampert, C.M.

    1978-08-01

    The structure of Harshaw Chemicals' CHROM-ONYX type of black chrome/metal selective absorber was studied to gain a better understanding of its influence upon the mechanism of wavelength selectivity. Spectral reflectance measurements were performed on seven samples. In this study, the best selectivity was found by these measurements to be 1.0 micron of black chrome on copper and 0.7 micron of black chrome on nickel. Both transmission and scanning electron microscopy were employed to study microstructure and chemical composition. As a result of the combined studies, some effects of black chrome thickness and the metallic substrate were determined. It was foundmore » that black chrome consisted of a very fine metallic distribution of particles of chromium, possibly suspended within a matrix of an oxide of chromium. This combination was, in turn, agglomerated into larger particles within the 0.05--0.3 micron size range. These larger particles formed a network which constituted the surface coating.« less

  11. Mortality in a cohort of tannery workers.

    PubMed Central

    Montanaro, F; Ceppi, M; Demers, P A; Puntoni, R; Bonassi, S

    1997-01-01

    OBJECTIVES: To evaluate the mortality of a group of tannery workers. METHODS: The cohort consisted of 1244 workers (870 men and 374 women) employed at a chrome tannery between 1955 and 1988. A total of 36414 person-years of follow up was calculated (369 people had died). National and regional mortalities were used to estimate the expected numbers. RESULTS: All cause mortality was similar to that of the general population. The most remarkable excess was for bladder cancer (observed 10, standardised mortality ratio (SMR) 242, 95% confidence interval (95% CI) 116 to 446). An excess of colorectal cancer (observed 17, SMR 180, 95% CI 105 to 288) was also found, based on an increased risk of both colon (SMR 166) and rectal cancer (SMR 206). No recognisable patterns emerged from the analyses by years since first employment, calendar year of hire, or lagging exposures. CONCLUSIONS: The increased mortality from bladder cancer is likely due to exposure to benzidine based leather dyes. If the apparent excess of colorectal cancer is real, its causes are as yet unknown. PMID:9326162

  12. LABORATORY STUDY FOR THE REDUCTION OF CHROME (VI) TO CHROME (III) USING SODIUM METABISULFITE UNDER ACIDIC CONDITIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DUNCAM JB; GUTHRIE MD; LUECK KJ

    2007-07-18

    This report describes the results from RPP-PLAN-32738, 'Test Plan for the Effluent Treatment Facility to Reduce Chrome(VI) to Chrome(I1I) in the Secondary Waste Stream', using sodium metabisulfite. Appendix A presents the report as submitted by the Center for Laboratory Sciences (CLS) to CH2M HILL Hanford Group, Inc. The CLS carried out the laboratory effort under Contract Number 21065, release Number 30. This report extracts the more pertinent aspects of the laboratory effort.

  13. FINAL REPORT FOR THE REDUCTION OF CHROME (VI) TO CHROME (III) IN THE SECONDARY WASTE STREAM OF THE EFFLUENT TREATMENT FACILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DUNCAN JB; GUTHRIE MD

    2008-08-29

    This report documents the laboratory results of RPP-PLAN-35958, Test Plan for the Effluent Treatment Facility to Reduce Chrome (VI) to Chrome (III) in the Secondary Waste Stream With the exception of the electrochemical corrosion scans, all work was carried out at the Center for Laboratory Science (CLS) located at the Columbia Basin College. This document summarizes the work carried out at CLS and includes the electrochemical scans and associated corrosion rates for 304 and 316L stainless steel.

  14. Osseointegration and biocompatibility of different metal implants - a comparative experimental investigation in sheep

    PubMed Central

    2012-01-01

    Background In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. Methods Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. Results Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. Conclusion This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior. PMID:22400715

  15. Hexavalent Chrome Free Coatings for Electronics: Electromagnetic Interference (EMI) Shielding Effectiveness (SE)

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2016-01-01

    Determine the suitability of trivalent chromium conversion coatings that meet the requirements of MIL-DTL-5541, Type II, for use in applications where high-frequency electrical performance is important. Evaluate the ability of hexavalent chrome free pretreated aluminum to form adequate EMI seals, and maintain that seal while being subjected to harsh environmental conditions. Assess the performance of trivalent chromium pretreatments against a known control hexavalent chrome pretreatment before and after they have been exposed to a set of environmental conditions. It is known that environmental testing causes a decrease in shielding effectiveness when hexavalent chrome pretreatments are used (Alodine 1200s). Need to determine how shielding effectiveness will be affected with the use of hexavalent chrome free pretreatments. Performance will be assessed by evaluating shielding effectiveness (SE) test data from a variety of test samples comprised of different aluminum types and/or conversion coatings. The formation of corrosion will be evaluated between the mating surfaces and gasket to assess the corrosion resistant properties of the pretreatments, comparing the hexavalent control to the hexavalent chrome free pretreatments.

  16. Biomonitoring at the UK Health and Safety Laboratory.

    PubMed

    Cocker, J; Jones, K; Morton, J; Mason, H J

    2007-05-01

    The UK Health and Safety Laboratory (HSL) provides research and analytical support to the Health and Safety Executive, other Government Departments and employers. In the area of biomonitoring HSL conducts research studies and provides an analytical service for regular surveillance of worker exposure to hazardous substances. This paper gives brief examples of how data from such studies can be used to develop biological monitoring guidance values for isocyanates, polycyclic aromatic hydrocarbons and hexavalent chromium. In addition, a study of occupational exposure to copper chrome arsenic wood preservatives is briefly described to show how biological monitoring can be used for post-approval surveillance of a biocide.

  17. Performance evaluation of two black nickel and two black chrome solar collectors

    NASA Technical Reports Server (NTRS)

    Losey, R.

    1977-01-01

    The test program was based on the evaluation of four unique solar collectors described below: (1) black nickel collector surface with a desiccant drying bed, (2) black nickel collector surface without a desiccant drying bed, (3) black chrome collector surface with a dessicant drying bed, and (4) black chrome collector surface without a desiccant drying bed. The test program included three distinct phases: Initial performance evaluation, natural environmental aging, and post-aging performance evaluation. Results of Phase III testing conclusively indicated a higher normalized efficiency for Black Chrome surfaces when compared to Black Nickel.

  18. 40 CFR 425.10 - Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory. 425.10 Section 425.10 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome...

  19. 40 CFR 425.20 - Applicability; description of the hair save, chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the hair save, chrome tan, retan-wet finish subcategory. 425.20 Section 425.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan,...

  20. 40 CFR 425.10 - Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet Finish Subcategory § 425.10 Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory. The provisions of this subpart are...

  1. 40 CFR 425.10 - Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet Finish Subcategory § 425.10 Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory. The provisions of this subpart are...

  2. 40 CFR 425.10 - Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Applicability; description of the hair... POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet Finish Subcategory § 425.10 Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory. The provisions of this subpart are...

  3. 40 CFR 425.20 - Applicability; description of the hair save, chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet Finish Subcategory § 425.20 Applicability; description of the hair save, chrome tan, retan-wet finish subcategory. The provisions of this subpart are...

  4. 40 CFR 425.10 - Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet Finish Subcategory § 425.10 Applicability; description of the hair pulp, chrome tan, retan-wet finishing subcategory. The provisions of this subpart are...

  5. 40 CFR 425.20 - Applicability; description of the hair save, chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Applicability; description of the hair... POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet Finish Subcategory § 425.20 Applicability; description of the hair save, chrome tan, retan-wet finish subcategory. The provisions of this subpart are...

  6. 40 CFR 425.20 - Applicability; description of the hair save, chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet Finish Subcategory § 425.20 Applicability; description of the hair save, chrome tan, retan-wet finish subcategory. The provisions of this subpart are...

  7. 40 CFR 425.20 - Applicability; description of the hair save, chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet Finish Subcategory § 425.20 Applicability; description of the hair save, chrome tan, retan-wet finish subcategory. The provisions of this subpart are...

  8. Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report

    NASA Technical Reports Server (NTRS)

    Rothgeb, Matt; Kessel, Kurt

    2013-01-01

    The overall objective of the Hexavalent Chrome Free Coatings for Electronics Applications project is to evaluate and test pretreatments not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.

  9. Hex Chrome Free Coatings for Electronics Overview

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt

    2013-01-01

    The overall objective of the Hex Chrome Free Coatings for Electronics project is to evaluate and test pretreatment coating systems not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders.

  10. Increase of olfactory threshold in plating factory workers exposed to chromium in Korea.

    PubMed

    Kitamura, Fumihiko; Yokoyama, Kazuhito; Araki, Shunichi; Nishikitani, Mariko; Choi, Jae-Wook; Yum, Youg-Tae; Park, Hee-Chan; Park, Sang-Hwoi; Sato, Hajime

    2003-07-01

    To disclose the effects of chromium (Cr) on olfactory function, olfactory threshold tests were conducted on 27 male plating workers (Cr workers) with signs and symptoms of olfactory irritation but without nasal septum perforation or ulcer and on 34 male control subjects in Korean plating factories. The Cr workers had been exposed to Cr fume for 0.9 to 18.2 (mean 7.9) years; their blood Cr concentrations (0.16-3.69, mean 1.29 microg/dl) were significantly higher than those of the 34 control subjects (0.04-1.95, mean 0.55 microg/dl). Scores on recognition thresholds among the Cr workers were significantly higher than those of the control subjects (p < 0.05) and related positively and significantly to the exposure periods of the 27 Cr workers (p < 0.05). Olfactory thresholds were not significantly different between the Cr workers with and without nasal signs or symptoms, except that the scores on the recognition threshold were significantly higher in those experiencing difficulty with smell (p < 0.05). It is suggested that olfactory threshold is affected by Cr without development of nasal septum perforation or ulceration.

  11. Molecular spectroscopic study for suggested mechanism of chrome tanned leather

    NASA Astrophysics Data System (ADS)

    Nashy, Elshahat H. A.; Osman, Osama; Mahmoud, Abdel Aziz; Ibrahim, Medhat

    2012-03-01

    Collagen represents the structural protein of the extracellular matrix, which gives strength of hides and/or skin under tanning process. Chrome tan is the most important tanning agent all over the world. The methods for production of leather evolved over several centuries as art and engineering with little understanding of the underlying science. The present work is devoted to suggest the most probable mechanistic action of chrome tan on hide proteins. First the affect of Cr upon hide protein is indicated by the studied mechanical properties. Then the spectroscopic characterization of the hide protein as well as chrome tanned leather was carried out with Horizontal Attenuated Total Reflection (HATR) FT-IR. The obtained results indicate how the chromium can attached with the active sites of collagen. Molecular modeling confirms that chromium can react with amino as well as carboxylate groups. Four schemes were obtained to describe the possible interactions of chrome tan with hide proteins.

  12. Rolling element fatigue testing of gear materials

    NASA Technical Reports Server (NTRS)

    Nahm, A. H.

    1978-01-01

    Rolling element fatigue lives of nine alloys were evaluated in Rolling Contact (RC) rigs. Test conditions included a Hertzian stress at 4,826 MPa (700 ksi), a rolling speed of 6.23 m/sec (245 in/sec.). Tests were run with a Type I oil (MIL-L-7808G) at room temperature. B-10 lives (10% failure rate) of alloys were compared versus reference alloys, VIM-VAR AISI M-50 and VAR AISI 9310. Six case carburizing alloys (AISI 9310, CBS600, CBS1000M, EX00014, Vasco X-2 and EX00053) and three through-hardening alloys (AISI M-50, VascoMax 350 and Vasco Matrix 2 evaluated, showed RCF performance inferior or equivalent to that of AISI 9310 and AISI M-50. It was also found that the effects of vacuum melting processes, different tempering temperatures, freezing cycle during heat treating, shot peening, gold plating and chrome plating employed in the present investigation did not significantly affect RCF life.

  13. SUPERFUND TREATABILITY CLEARINGHOUSE: SOIL STABILIZATION PILOT STUDY, UNITED CHROME NPL SITE PILOT STUDY AND HEALTH AND SAFETY PROGRAM, UNITED CHROME NPL SITE PILOT STUDY

    EPA Science Inventory

    This document is a project plan for a pilot study at the United Chrome NPL site, Corvallis, Oregon and includes the health and safety and quality assurance/quality control plans. The plan reports results of a bench-scale study of the treatment process as iieasured by the ...

  14. 40 CFR 425.30 - Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Applicability; description of the hair... TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome Tan, Retan-Wet Finish Subcategory § 425.30 Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish...

  15. 40 CFR 425.30 - Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Applicability; description of the hair... TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome Tan, Retan-Wet Finish Subcategory § 425.30 Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish...

  16. 40 CFR 425.30 - Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Applicability; description of the hair... FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome Tan, Retan-Wet Finish Subcategory § 425.30 Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory. The...

  17. 40 CFR 425.30 - Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Applicability; description of the hair... TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome Tan, Retan-Wet Finish Subcategory § 425.30 Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish...

  18. Novel Chemical Process for Producing Chrome Coated Metal

    PubMed Central

    Pelar, Christopher; Greenaway, Karima; Zea, Hugo; Wu, Chun-Hsien

    2018-01-01

    This work demonstrates that a version of the Reduction Expansion Synthesis (RES) process, Cr-RES, can create a micron scale Cr coating on an iron wire. The process involves three steps. I. A paste consisting of a physical mix of urea, chrome nitrate or chrome oxide, and water is prepared. II. An iron wire is coated by dipping. III. The coated, and dried, wire is heated to ~800 °C for 10 min in a tube furnace under a slow flow of nitrogen gas. The processed wires were then polished and characterized, primarily with scanning electron microscopy (SEM). SEM indicates the chrome layer is uneven, but only on the scale of a fraction of a micron. The evidence of porosity is ambiguous. Elemental mapping using SEM electron microprobe that confirmed the process led to the formation of a chrome metal layer, with no evidence of alloy formation. Additionally, it was found that thickness of the final Cr layer correlated with the thickness of the precursor layer that was applied prior to the heating step. Potentially, this technique could replace electrolytic processing, a process that generates carcinogenic hexavalent chrome, but further study and development is needed. PMID:29303977

  19. Novel Chemical Process for Producing Chrome Coated Metal.

    PubMed

    Pelar, Christopher; Greenaway, Karima; Zea, Hugo; Wu, Chun-Hsien; Luhrs, Claudia C; Phillips, Jonathan

    2018-01-05

    This work demonstrates that a version of the Reduction Expansion Synthesis (RES) process, Cr-RES, can create a micron scale Cr coating on an iron wire. The process involves three steps. I. A paste consisting of a physical mix of urea, chrome nitrate or chrome oxide, and water is prepared. II. An iron wire is coated by dipping. III. The coated, and dried, wire is heated to ~800 °C for 10 min in a tube furnace under a slow flow of nitrogen gas. The processed wires were then polished and characterized, primarily with scanning electron microscopy (SEM). SEM indicates the chrome layer is uneven, but only on the scale of a fraction of a micron. The evidence of porosity is ambiguous. Elemental mapping using SEM electron microprobe that confirmed the process led to the formation of a chrome metal layer, with no evidence of alloy formation. Additionally, it was found that thickness of the final Cr layer correlated with the thickness of the precursor layer that was applied prior to the heating step. Potentially, this technique could replace electrolytic processing, a process that generates carcinogenic hexavalent chrome, but further study and development is needed.

  20. Bone generation in the reconstruction of a critical size calvarial defect in an experimental model.

    PubMed

    Por, Yong-Chen; Barceló, C Raul; Salyer, Kenneth E; Genecov, David G; Troxel, Karen; Gendler, El; Elsalanty, Mohammed E; Opperman, Lynne A

    2008-03-01

    This study was designed to investigate the optimal combination of known osteogenic biomaterials with shape conforming struts to achieve calvarial vault reconstruction, using a canine model. Eighteen adolescent beagles were divided equally into 6 groups. A critical-size defect of 6 x 2 cm traversed the sagittal suture. The biomaterials used for calvarial reconstruction were demineralized perforated bone matrix (DBM), recombinant human bone morphogenetic protein 2 (rhBMP2), and autogenous platelet-rich plasma (PRP). The struts used were cobalt chrome (metal) or resorbable plate. The groupings were as follows: 1) DBM + metal, 2) DBM + PRP + metal, 3) DBM + PRP + resorbable plate, 4) DBM + rhBMP2 + metal, 5) DBM + rhBMP2 + PRP + metal, and 6) DBM + rhBMP2 + resorbable plate. Animals were killed at 3 months after surgery. There was no mortality or major complications. Analysis was performed macroscopically and histologically and with computed tomography. There was complete bony regeneration in the rhBMP2 groups only. Non-rhBMP2 groups had minimal bony ingrowth from the defect edges and on the dural surface, a finding confirmed by computed tomographic scan and histology. Platelet-rich plasma did not enhance bone regeneration. Shape conformation was good with both metal and resorbable plate. rhBMP2, but not PRP, accelerated calvarial regeneration in 3 months. The DBMs in the rhBMP2 groups were substituted by new trabecular bone. Shape molding was good with both metal and resorbable plate.

  1. Ultraviolet Curable Powder Coatings With Robotic Curing for Aerospace Applications

    DTIC Science & Technology

    2011-02-01

    Problem: DoD spends millions of dollars annually on solvent- based coatings Hexavalent chrome primer use still very widespread Many topcoats contain...cure functionality can be added Various advanced non- chrome corrosion inhibitors DISTRIBUTION A. Approved for public release; distribution...chromate), Alodine 8800 (sol-gel) and Alodine 5200 (Zr chemistry) Fair to poor results over Alodine 1200S (chromate), and Alodine 5900 (tri- chrome

  2. SU-E-T-328: Dosimetric Impact of Cobalt-Chrome Stabilization Hardware in Paraspinal Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, G; LoSasso, T; Saleh, Z

    2015-06-15

    Purpose: Due to saturation, high density materials Result in an apparent density of 3.2 g/cm{sup 3} in CT images. The true density of traditional titanium stabilization rods (∼4.4 g/cm{sup 3}) is typically ignored in treatment planning. This may not be acceptable for new cobalt-chrome rods with a density of 8.5 g/cm{sup 3}. This study reports the dosimetric impact of cobalt-chrome rods in paraspinal radiotherapy. Methods: For titanium and cobalt-chrome rods, two planning studies were done for both IMRT and VMAT in Varian Eclipse using AAA. 1) The effect of planning without assigning the true rod density was assessed by comparingmore » plans generated with the apparent density and recalculated with the true density for titanium and cobalt-chrome. 2) To test if TPS can compensate for high density rods during optimization. Furthermore, TPS calculation accuracy was verified using MapCheck for a single 20 x 10 cm{sup 2} field. The MapCheck was incrementally shifted to achieve measurement resolution of 1 mm. Results: PTV coverage was ∼0.3% and ∼4.7% lower in plans that were recalculated with the true rod density of titanium and cobalt-chrome, respectively. PTV coverage can be maintained if the correct density is used in optimization. Measurements showed that TPS overestimated the dose locally by up to 11% for cobalt-chrome rods and up to 4% for titanium rods if the density is incorrect. With density corrected, maximum local differences of 6% and 3% were seen for cobalt-chrome and titanium rods, respectively. At 2 cm beneath a rod, electrons scattered from the side of the rod increased the lateral dose and diminished as depth increases. TPS was not able to account for this effect properly even with the true rod density assigned. Conclusion: Neglecting the true density of cobalt-chrome rods can cause under coverage to the PTV. Assigning the correct density during treatment planning can minimize unexpected decrease in PTV dose.« less

  3. Molecular spectroscopic study for suggested mechanism of chrome tanned leather.

    PubMed

    Nashy, Elshahat H A; Osman, Osama; Mahmoud, Abdel Aziz; Ibrahim, Medhat

    2012-03-01

    Collagen represents the structural protein of the extracellular matrix, which gives strength of hides and/or skin under tanning process. Chrome tan is the most important tanning agent all over the world. The methods for production of leather evolved over several centuries as art and engineering with little understanding of the underlying science. The present work is devoted to suggest the most probable mechanistic action of chrome tan on hide proteins. First the affect of Cr upon hide protein is indicated by the studied mechanical properties. Then the spectroscopic characterization of the hide protein as well as chrome tanned leather was carried out with Horizontal Attenuated Total Reflection (HATR) FT-IR. The obtained results indicate how the chromium can attached with the active sites of collagen. Molecular modeling confirms that chromium can react with amino as well as carboxylate groups. Four schemes were obtained to describe the possible interactions of chrome tan with hide proteins. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. NASA TEERM Hexavalent Chrome Alternatives Projects

    NASA Technical Reports Server (NTRS)

    Rothgeb, Matt

    2009-01-01

    This slide presentation reviews the NASA/DOD projects to select an alternative to hexavalent chrome in the aerospace industry. The Phase I process of the project performed: (1) Evaluation and testing of non-chromated coating systems as replacements for hexavalent chrome coatings in aircraft and aerospace applications. (2) Testing of coating systems to DoD and NASA specifications for corrosion resistance and adhesion. (3) Bare corrosion resistance and atmospheric exposure will be focus areas of Phase II Testing. The description includes a chart that summarizes the 3000 hour salt fog test results. The second phase of the project includes (1) Evaluation and testing of coating systems that do not contain hexavalent chrome as replacements for aerospace applications. (2) Evaluation of coatings at Beach Test Site and Launch Complex 39B (3) Evaluation of non-chrome coatings for electronic housings (bare corrosion resistance and electrical impedance) is a part of this round of testing. This project was performed for the Technology Evaluation for Environmental Risk Mitigation (TEERM)

  5. Monitoring of cellular enzymes in the serum of electroplating workers at Coimbatore.

    PubMed

    Saraswathy, C P; Usharani, M V

    2007-04-01

    Chromium compounds are potent toxic and carcinogenic substances. With respect to toxicity, hepatic and renal toxicity have been reported both in workers and in animals exposed to chromium (VI). Chromium (VI) compounds induces DNA damage in vivo and in cultured cells as well as the cytotoxicity evaluated by the leakage of lactate dehydrogenase. The present study reports the cytotoxicity of chrome platers who are employed from 8 to 25 years in electroplating industries at Coimbatore, Tamilnadu. Blood samples were collected and estimated for glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), alkaline phosphatase (ALP), lactate dehydrogenase (LDH), creatine phosphokinase (CPK) and total protein in the serum. The study revealed that there is a significant elevation in the level of LDH, ALP, CPK and transaminases and a decrease in total protein in serum. The results of the study suggests that chromium (VI), a hepatotoxic chemical may perhaps damage the plasma membrane resulting in leakage of enzymes in to the serum of chromeplaters.

  6. Safety evaluation of traces of nickel and chrome in cosmetics: The case of Dead Sea mud.

    PubMed

    Ma'or, Ze'evi; Halicz, Ludwik; Portugal-Cohen, Meital; Russo, Matteo Zanotti; Robino, Federica; Vanhaecke, Tamara; Rogiers, Vera

    2015-12-01

    Metal impurities such as nickel and chrome are present in natural ingredients-containing cosmetic products. These traces are unavoidable due to the ubiquitous nature of these elements. Dead Sea mud is a popular natural ingredient of cosmetic products in which nickel and chrome residues are likely to occur. To analyze the potential systemic and local toxicity of Dead Sea mud taking into consideration Dead Sea muds' natural content of nickel and chrome. The following endpoints were evaluated: (Regulation No. 1223/20, 21/12/2009) systemic and (SCCS's Notes of Guidance) local toxicity of topical application of Dead Sea mud; health reports during the last five years of commercial marketing of Dead Sea mud. Following exposure to Dead Sea mud, MoS (margin of safety) calculations for nickel and chrome indicate no toxicological concern for systemic toxicity. Skin sensitization is also not to be expected by exposure of normal healthy skin to Dead Sea mud. Topical application, however, is not recommended for already nickel-or chrome-sensitized persons. As risk assessment of impurities present in cosmetics may be a difficult exercise, the case of Dead Sea mud is taken here as an example of a natural material that may contain traces of unavoidable metals. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  7. A comparison of Staphylococcus aureus biofilm formation on cobalt-chrome and titanium-alloy spinal implants.

    PubMed

    Patel, Shalin S; Aruni, Wilson; Inceoglu, Serkan; Akpolat, Yusuf T; Botimer, Gary D; Cheng, Wayne K; Danisa, Olumide A

    2016-09-01

    The use of cobalt chrome (CoCr) implants in spinal surgery has become increasingly popular. However, there have been no studies specifically comparing biofilm formation on CoCr with that of titanium-alloy spinal implants. The objective of this study was to compare the difference in propensity for biofilm formation between these two materials, as it specifically relates to spinal rods. Staphylococcus aureus subsp. Aureus (ATCC 6538) were incubated with two different types of spinal rods composed of either CoCr or titanium-alloy. The spinal rods were then subject to a trypsin wash to allow for isolation of the colonized organism and associated biofilms. The associated optical density values (OD) from the bacterial isolates were obtained and the bacterial solutions were plated on brain-heart infusion agar plates and the resultant colony-forming units (CFU) were counted. The OD values for the titanium-alloy rods were 1.105±0.096nm (mean±SD) and 1.040±0.026nm at 48hours and 96hours, respectively. In contrast, the OD values for the CoCr rods were 1.332±0.161nm and 1.115±0.207nm at 48 and 96hours, respectively (p<0.05). The CFU values were 1481±417/100mm(2) and 745±159/100mm(2) at 48 and 96hours, respectively for the titanium-alloy group. These values were significantly lower than the CFU values obtained from the CoCr group which were 2721±605/100mm(2) and 928±88/100mm(2) (p<0.001) at both 48 and 96hours respectively. Our findings, evaluating both the OD and CFU values, indicate that implants composed of CoCr had a higher proclivity towards biofilm formation compared to titanium-alloy implants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The Petrogenesis of the Unit 7/8 and 11/12 Chrome-spinel Seams of the Rum Eastern Layered Intrusion (NW Scotland) Re-evaluated

    NASA Astrophysics Data System (ADS)

    O'Driscoll, B.; Daly, J. S.; Emeleus, C. H.; Donaldson, C. H.

    2007-12-01

    Laterally extensive (~2 mm thick) chrome-spinel seams in the Rum Layered Suite, NW Scotland, occur at the junctions of several of the coupled peridotite-troctolite macro-rhythmic units that make up the bulk of the eastern part of the intrusion. A detailed petrographic study of the rocks immediately above and below two of these seams suggests that existing models for seam formation involving early crystallisation and gravitational settling of chrome-spinel crystals from a newly emplaced body of picritic magma may be flawed. Instead, the textural relationships between minerals suggest that olivine crystallisation in the peridotite above each of the seams occurred before that of most of the chrome-spinel. Reaction textures between olivine and chrome-spinel crystals are commonly observed, with plagioclase usually occurring as thin rims between both olivine and chrome-spinel where both are in close proximity. The textural evidence suggests a significant degree of olivine crystal-shape change; it seems that many of the olivine crystals immediately above the main seams may initially have had much more complex (harrisitic) crystal shapes before modification to simpler morphologies in a crystal mush. Plagioclase occurs in the peridotite as large oikocrysts up to several cm in size. Additionally, the chrome-spinel seams occur only in those units that display extensive evidence of syn-magmatic deformation of unconsolidated cumulate in the underlying troctolite, and the seams themselves often exhibit small-scale load structures. A model suggesting in-situ crystallisation of the chrome-spinel seams is proposed, whereby mixing of an evolved interstitial liquid with a primitive picritic melt occurred approximately at the crystal mush-magma interface. The former was released from the unconsolidated troctolite mush as a response to re-mobilization and chaotic slumping, possibly triggered by emplacement of some of the hot picrite into the crystal mush pile. Significant undercooling in the picrite due to emplacement-related cooling had already produced a crystal framework comprising complex skeletal olivine crystal morphologies with very fast growth rates. It is envisaged that the significantly modified olivine textures in the peridotite immediately above both seams can be attributed to upward- moving porosity waves of the same 'mixed' interstitial melt that precipitated the chrome-spinel seams. In addition to formation of the seams at the main unit junctions, 'necklace' or 'chain-like' distributions of chrome-spinel crystals around olivine crystals in the peridotite, as well as the large plagioclase oikocrysts, argue for the presence of a mobile interstitial melt with a protracted cooling history.

  9. Occurrences, uses, and properties of chromium.

    PubMed

    Barnhart, J

    1997-08-01

    Chromium is the 21st most abundant element in the Earth's crust with a mean concentration in United States soils of about 40 mg/kg. Although it exists in several oxidation states, the zero, trivalent, and hexavalent states are the most important in commercial products and the environment. Nearly all naturally occurring chromium is in the trivalent state, usually in combination with iron or other metal oxides. Although only about 15% of the chromium mined is used in the manufacture of chemicals, most applications of chromium utilize the chemistry of chromium. For instance, the "stainless" nature of stainless steel is due to the chemical properties of the chromium oxides which form on the surface of the alloy. Similarly, the protective properties of chrome plating of metals, chromated copper arsenate (CCA) treatment of wood, and chrome tanning of leather are all dependent on chromium chemistry. The key to these uses is that under typical environmental and biological conditions of pH and oxidation-reduction potential, the most stable form of chromium is the trivalent oxide. This form has very low solubility and low reactivity resulting in low mobility in the environment and low toxicity in living organisms. In this paper the chemical properties of chromium are discussed for the major commercial products in the context of the Eh-pH diagram for chromium. Copyright 1997 Academic Press.

  10. Installation Restoration Program. Phase 1. Records Search. Air Force Plant Number 3, Tulsa, Oklahoma

    DTIC Science & Technology

    1983-12-01

    treatment plant was designed for cyanide and chromium treat- ment. Wastes are collected in two separate sewer systems; acid-chrome, and alkali cyanide...reduction of hexavalent chrome to trivalent chrome with sulfur dioxide. After the oxidation and reduction are accomplished separately, the wastes are...uses of the water. CCNVEPSI N COATING WASTE: Acidic solution containinq chromium . 0COOLANT: An oil-water mixture used for coolina metal parts durirq

  11. C-130 Corrosion Prevention and Control Program

    DTIC Science & Technology

    2011-08-01

    hexavalent chrome … Warner Robins Air Logistics Center People First…Mission Always SIBR Projects  Back Scatter X-Ray NDI  Detect concealed...Projects Listing Future Projects  Chrome -Free Coating Systems Flight Tests • AkzoNobel (Sep-Oct 2011) – PreKote – Aerodur 2100 magnesium rich...primer (MgRP) – Aerodur 5000 topcoat color #36173 • Deft (June 2012) – Rare earth conversion coating (RECC) 1015/3021 – 02-GN-093 chrome -free

  12. Acquisition Documentation Streamlining, the SEP, and the PESHE

    DTIC Science & Technology

    2012-05-21

    identifying any other ESOH requirements (e.g., ban on use of Ozone Depleting Substances or hexavalent chrome )  "Description/Comments:" Use 2-3...limitations on use of hexavalent chrome )  "Description/Comments:" Use 2-3 paragraphs to describe the strategy for integrating ESOH into SE processes...optional tasks) and identifying any other ESOH requirements (e.g., ban on use of Ozone Depleting Substances or hexavalent chrome )  "Description

  13. Apoptosis of lymphocytes in the presence of Cr(V) complexes: role in Cr(VI)-induced toxicity.

    PubMed

    Vasant, C; Balamurugan, K; Rajaram, R; Ramasami, T

    2001-08-03

    Cr(VI) compounds have been declared as a potent occupational carcinogen by IARC (1990) through epidemiological studies among workers in chrome plating, stainless-steel, and pigment industries. Studies relating to the role of intermediate oxidation states such as Cr(V) and Cr(IV) in Cr(VI)-induced carcinogenicity are gaining importance. In this study, issues relating to toxicity elicited by Cr(V) have been addressed and comparisons made with those relating to Cr(VI) employing human peripheral blood lymphocytes. Lymphocytes have been isolated from heparinized blood by Ficoll-Hypaque density gradient centrifugation and exposed to Cr(V) complexes viz. sodium bis(2-ethyl-2-hydroxybutyrato)oxochromate(V), Na[Cr(V)O(ehba)(2)], 1 and sodium bis(2-hydroxy-2-methylbutyrato)oxochromate(V), Na[Cr(V)O(hmba)(2)], 2 and Cr(VI). The phytohemagglutinin (PHA)-induced proliferation of lymphocytes has been found to be inhibited by the two complexes of Cr(V) and chromate Cr(VI) in a time- and concentration-dependent manner. Viability of cells decreases in the presence of Cr(V). Apoptosis appears to be the mode of cell death in the presence of both Cr(V) and Cr(VI). Pretreatment of cells with antioxidants before exposure to chromium(V) complexes reverse apoptosis partially. Possibility for the formation and implication of reactive oxygen species in Cr(V)-induced apoptosis of human lymphocyte cells has been indicated in this investigation. The intermediates of Cr(V) and radical species in the biotoxic pathways elicited by Cr(VI) seems feasible. Copyright 2001 Academic Press.

  14. Gun Liner Emplacement With an Elastomeric Material

    DTIC Science & Technology

    2010-04-01

    Introduction The U.S. Army uses liners or coatings in many of its guns currently in service. This includes a chrome coating in the M256 main tank...coatings increase the barrel wear life of those guns by protecting them against the effects of hot propellant gasses. Chrome coatings are applied by...CCM is a chrome -cobalt alloy that is used for medical implants. The tube was machined from a solid bar of metal. The load frame was programmed to

  15. Electrodeposition of Nanocrystalline Co-P Coatings as a Hard Chrome Alternative

    DTIC Science & Technology

    2009-09-02

    Electrodeposition  of Nanocrystalline Co‐P  Coatings as a Hard Chrome Alternative Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden...AND SUBTITLE Electrodeposition of Nanocrystalline Co‐P Coatings as a Hard Chrome Alternative 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c...Defense Conference – 2 September 2009 Conventional  Electrodeposits Polycrystalline (10‐100 µm) Electrodeposited Nanocrystalline Materials Pulsed

  16. Solar industrial process heat: A study of applications and attitudes

    NASA Astrophysics Data System (ADS)

    Wilson, V.

    1981-04-01

    Data were gathered through site visits to 100 industrial plants. The site specific data suggests several possible near term market opportunities for solar thermal energy systems. Plants using electricity as their primary fuel for industrial process heat were identified, on the basis of their high fuel prices, as attractive early entry markets for solar energy. Additional opportunities were reflected in plants that had accomplished much of their conservation plans, or bad sizeable percentages of their operating budgets committed to energy expenses. A suitability analysis identified eleven industrial plants as highly suitable for solar thermal applications, they included producers of fluid milk, pottery, canned and bottled soft drinks, fabricated structural metal, refined petroleum, aluminum cans, chrome and nickel plating and stamped frame metal and metal finishings.

  17. Development of CMOS MEMS inductive type tactile sensor with the integration of chrome steel ball force interface

    NASA Astrophysics Data System (ADS)

    Yeh, Sheng-Kai; Chang, Heng-Chung; Fang, Weileun

    2018-04-01

    This study presents an inductive tactile sensor with a chrome steel ball sensing interface based on the commercially available standard complementary metal-oxide-semiconductor (CMOS) process (the TSMC 0.18 µm 1P6M CMOS process). The tactile senor has a deformable polymer layer as the spring of the device and no fragile suspended thin film structures are required. As a tactile force is applied on the chrome steel ball, the polymer would deform. The distance between the chrome steel ball and the sensing coil would changed. Thus, the tactile force can be detected by the inductance change of the sensing coil. In short, the chrome steel ball acts as a tactile bump as well as the sensing interface. Experimental results show that the proposed inductive tactile sensor has a sensing range of 0-1.4 N with a sensitivity of 9.22(%/N) and nonlinearity of 2%. Preliminary wireless sensing test is also demonstrated. Moreover, the influence of the process and material issues on the sensor performances have also been investigated.

  18. Biological and chemical removal of Cr(VI) from waste water: cost and benefit analysis.

    PubMed

    Demir, Aynur; Arisoy, Münevver

    2007-08-17

    The objective of the present study is cost and benefit analysis of biological and chemical removal of hexavalent chromium [Cr(VI)] ions. Cost and benefit analysis were done with refer to two separate studies on removal of Cr(VI), one of heavy metals with a crucial role concerning increase in environmental pollution and disturbance of ecological balance, through biological adsorption and chemical ion-exchange. Methods of biological and chemical removal were compared with regard to their cost and percentage in chrome removal. According to the result of the comparison, cost per unit in chemical removal was calculated 0.24 euros and the ratio of chrome removal was 99.68%, whereas those of biological removal were 0.14 and 59.3% euros. Therefore, it was seen that cost per unit in chemical removal and chrome removal ratio were higher than those of biological removal method. In the current study where chrome removal is seen as immeasurable benefit in terms of human health and the environment, percentages of chrome removal were taken as measurable benefit and cost per unit of the chemicals as measurable cost.

  19. The CHROME Honors Program

    NASA Technical Reports Server (NTRS)

    Wilson, Eleanor

    2002-01-01

    The CHROME Honors Program was designed as a two-week residential program for 9th and 1Oth grade students participating in CHROME clubs. The curriculum focused on the health sciences with instruction from: (1) the science and health curriculum of the Dozoretz National Program for Minorities in Applied Sciences (DNIMAS) Program of Norfolk State University (NSU); (2) the humanities curriculum of the NSU Honors Program; (3) NASA-related curriculum in human physiology. An Advisory Committee was formed to work with the Project Coordinator in the design of the summer program.

  20. Weight of Polyethylene Wear Particles is Similar in TKAs with Oxidized Zirconium and Cobalt-chrome Prostheses

    PubMed Central

    Kim, Jun-Shik; Huh, Wansoo; Lee, Kwang-Hoon

    2009-01-01

    Background The greater lubricity and resistance to scratching of oxidized zirconium femoral components are expected to result in less polyethylene wear than cobalt-chrome femoral components. Questions/purposes We examined polyethylene wear particles in synovial fluid and compared the weight, size (equivalent circle diameter), and shape (aspect ratio) of polyethylene wear particles in knees with an oxidized zirconium femoral component with those in knees with a cobalt-chrome femoral component. Patients and Methods One hundred patients received an oxidized zirconium femoral component in one knee and a cobalt-chrome femoral component in the other. There were 73 women and 27 men with a mean age of 55.6 years (range, 44–60 years). The minimum followup was 5 years (mean, 5.5 years; range, 5–6 years). Polyethylene wear particles were analyzed using thermogravimetric methods and scanning electron microscopy. Results The weight of polyethylene wear particles produced at the bearing surface was 0.0223 ± 0.0054 g in 1 g synovial fluid in patients with an oxidized zirconium femoral component and 0.0228 ± 0.0062 g in patients with a cobalt-chrome femoral component. Size and shape of polyethylene wear particles were 0.59 ± 0.05 μm and 1.21 ± 0.24, respectively, in the patients with an oxidized zirconium femoral component and 0.52 ± 0.03 μm and 1.27 ± 0.31, respectively, in the patients with a cobalt-chrome femoral component. Knee Society knee and function scores, radiographic results, and complication rate were similar between the knees with an oxidized zirconium and cobalt-chrome femoral component. Conclusions The weight, size, and shape of polyethylene wear particles were similar in the knees with an oxidized zirconium and a cobalt-chrome femoral component. We found the theoretical advantages of this surface did not provide the actual advantage. Level of Evidence Level I, therapeutic study. See the guidelines for Authors for a complete description of levels of evidence. PMID:19949906

  1. Soybean plant growth study conducted using purified protein hydrolysate-based fertilizer made from chrome-tanned leather waste.

    PubMed

    Pati, Anupama; Chaudhary, Rubina

    2015-12-01

    Leather processing discharges enormous amount of chrome containing leather solid waste which creates a major disposal problem. Chrome-tanned leather solid waste is a complex of collagen and chromium. The presence of chromium limits protein application in fertilizer industry. The purified protein hydrolysate with zero chromium could be used as a nitrogen source for fertilizer formulation. In this study, an attempt has been made to employ purified protein hydrolysate derived from chrome-tanned leather shavings (CTLS) in formulation of fertilizer. The formulated fertilizer (1–3 t ha(-1)) is employed as nitrogen source in production of soybean. Plant growth study demonstrates that formulated fertilizer dosage 3 t ha(-1) produced similar effects of commercial fertilizer-treated plants. Application of formulated fertilizer yielded higher seed in plant than commercial fertilizer.

  2. CORROSION STUDY FOR THE EFFLUENT TREATMENT FACILITY (ETF) CHROME (VI) REDUCTANT SOLUTION USING 304 & 316L STAINLESS STEEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DUNCAN, J.B.

    2007-06-27

    The Effluent Treatment Facility has developed a method to regenerate spent resin from the groundwater pump and treat intercepting chrome(VI) plumes (RPP-RPT-32207, Laboratory Study on Regeneration of Spent DOWEX 21K 16-20 Mesh Ion Exchange Resin). Subsequent laboratory studies have shown that the chrome(VI) may be reduced to chrome(III) by titrating with sodium metabisulfite to an oxidation reduction potential (ORP) of +280 mV at a pH of 2. This test plan describes the use of cyclic potentiodynamic polarization and linear polarization techniques to ascertain the electrochemical corrosion and pitting propensity of the 304 and 316L stainless steel in the acidified reducingmore » the solution that will be contained in either the secondary waste receiver tank or concentrate tank.« less

  3. Manufacturing of ArF chromeless hard shifter for 65-nm technology

    NASA Astrophysics Data System (ADS)

    Park, Keun-Taek; Dieu, Laurent; Hughes, Greg P.; Green, Kent G.; Croffie, Ebo H.; Taravade, Kunal N.

    2003-12-01

    For logic design, Chrome-less Phase Shift Mask is one of the possible solutions for defining small geometry with low MEF (mask enhancement factor) for the 65nm node. There have been lots of dedicated studies on the PCO (Phase Chrome Off-axis) mask technology and several design approaches have been proposed including grating background, chrome patches (or chrome shield) for applying PCO on line/space and contact pattern. In this paper, we studied the feasibility of grating design for line and contact pattern. The design of the grating pattern was provided from the EM simulation software (TEMPEST) and the aerial image simulation software. AIMS measurements with high NA annular illumination were done. Resist images were taken on designed pattern in different focus. Simulations, AIMS are compared to verify the consistency of the process with wafer printed performance.

  4. Preliminary Results on the Use of Leather Chrome Shavings for Air Passive Sampling

    PubMed Central

    Sanjuán-Herráez, D.; Chabaane, L.; Tahiri, S.; Pastor, A.; de la Guardia, M.

    2012-01-01

    A new passive sampler based on low-density polyethylene (LDPE) layflat tube filled with chrome shavings from tannery waste residues was evaluated to determine volatile organic compounds (VOCs) in indoor and outdoor areas. VOCs were directly determined by head space-gas chromatography-mass spectrometry (HS-GC-MS) without any pretreatment of the sampler and avoiding the use of solvents. Limit of detection values ranging from 20 to 75 ng sampler−1 and good repeatability values were obtained for VOCs under study with relative standard deviation values from 2.8 to 9.6% except for carbon disulfide for which it was 22.5%. The effect of the amount of chrome shavings per sampler was studied and results were compared with those obtained using empty LDPE tubes, to demonstrate the capacity of chrome shavings to adsorb VOCs. PMID:22900233

  5. Nasal cancer in the Northamptonshire boot and shoe industry: is it declining?

    PubMed Central

    Acheson, E. D.; Pippard, E. C.; Winter, P. D.

    1982-01-01

    This paper reports a survey of nasal cancer in Northamptonshire during the period 1950-79. An increased risk of various histological types of nasal tumour has been observed within the footwear manufacturing industry, which seems to be limited to the minority of men and women exposed to the dust of leather soles and heels. In Northamptonshire this exposure has usually occurred in the preparation, press and finishing rooms of factories making boots and shoes by the welted process. This type of leather is tanned by treatment with vegetable extracts, not chrome salts. Although the population of workers involved has diminished over the period of the study there has been no evidence of a decline in incidence of these tumours within it. PMID:7150487

  6. A conceptual model for determining career choice of CHROME alumna based on farmer's conceptual models

    NASA Astrophysics Data System (ADS)

    Moore, Lisa Simmons

    This qualitative program evaluation examines the career decision-making processes and career choices of nine, African American women who participated in the Cooperating Hampton Roads Organization for Minorities in Engineering (CHROME) and who graduated from urban, rural or suburban high schools in the year 2000. The CHROME program is a nonprofit, pre-college intervention program that encourages underrepresented minority and female students to enter science, technically related, engineering, and math (STEM) career fields. The study describes career choices and decisions made by each participant over a five-year period since high school graduation. Data was collected through an Annual Report, Post High School Questionnaires, Environmental Support Questionnaires, Career Choice Questionnaires, Senior Reports, and standardized open-ended interviews. Data was analyzed using a model based on Helen C. Farmer's Conceptual Models, John Ogbu's Caste Theory and Feminist Theory. The CHROME program, based on its stated goals and tenets, was also analyzed against study findings. Findings indicated that participants received very low levels of support from counselors and teachers to pursue STEM careers and high levels of support from parents and family, the CHROME program and financial backing. Findings of this study also indicated that the majority of CHROME alumna persisted in STEM careers. The most successful participants, in terms of undergraduate degree completion and occupational prestige, were the African American women who remained single, experienced no critical incidents, came from a middle class to upper middle class socioeconomic background, and did not have children.

  7. A new design concept for wrist arthroplasty.

    PubMed

    Shepherd, D E T; Johnstone, A

    2005-01-01

    The wrist joint is frequently affected by arthritis, which leads to pain, loss of function and ultimately deformity. Various designs of wrist arthroplasty have been introduced to attempt to relieve pain and provide a functional range of motion. The first generation of wrist implant was a one-piece silicone elastomer. Later generations have designs that have two parts that articulate against each other. However, wrist implants have not achieved the same clinical success to date, compared with hip and knee implants, and there is a high revision rate associated with them. This paper describes a new design concept for wrist arthroplasty, based around the idea of combining the principles of an articulating implant with that of a flexible elastomer implant. The design consists of assembling a radial, carpal/metacarpal, plate and flexible parts together. The radial and carpal/metacarpal parts are to be made from ultra high molecular weight polyethylene. The bearing surfaces of the radial and carpal/metacarpal parts articulate against the flat surfaces of the plate, made from cobalt chrome molybdenum alloy. The radius on the bearing surface of the radial part enables flexion/extension, while the radius on the carpal/metacarpal surface enables radial/ulnar deviation. The articulation of the carpal/metacarpal part against the plate also allows for rotation as well as flexion/extension. The flexible part, made from Elast-Eon, which is a silicone polyurethane elastomer, is inserted through the hole of the plate and into the holes of the radial and carpal/metacarpal parts.

  8. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.

    PubMed

    Barbour, P S; Stone, M H; Fisher, J

    2000-01-01

    This study validates a hip joint simulator configuration as compared with other machines and clinical wear rates using smooth metal and ceramic femoral heads and ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. Secondly the wear rate of UHMWPE cups is measured in the simulator with deliberately scratched cobalt-chrome heads to represent the type of mild and severe scratch damage found on retrieved heads. Finally, the scratching processes are described and the resulting scratches compared with those found in retrieved cobalt-chrome heads. For smooth cobalt-chrome and zirconia heads the wear rates were found to be statistically similar to other simulator machines and within the normal range found from clinical studies. An increased wear rate was found with cobalt-chrome heads scratched using either the diamond stylus or the bead cobalt-chrome but the greatest increase was with the diamond scratched heads which generated scratches of similar dimensions to those on retrieved heads. A greater than twofold increase in wear rate is reported for these heads when compared with smooth heads. This increased wear rate is, however, still within the limits of data from clinical wear studies.

  9. Total control of chromium in tanneries - thermal decomposition of filtration cake from enzymatic hydrolysis of chrome shavings.

    PubMed

    Kocurek, P; Kolomazník, K; Bařinová, M; Hendrych, J

    2017-04-01

    This paper deals with the problem of chromium recovery from chrome-tanned waste and thus with reducing the environmental impact of the leather industry. Chrome-tanned waste was transformed by alkaline enzymatic hydrolysis promoted by magnesium oxide into practically chromium-free, commercially applicable collagen hydrolysate and filtration cake containing a high portion of chromium. The crude and magnesium-deprived chromium cakes were subjected to a process of thermal decomposition at 650°C under oxygen-free conditions to reduce the amount of this waste and to study the effect of magnesium removal on the resulting products. Oxygen-free conditions were applied in order to prevent the oxidation of trivalent chromium into the hazardous hexavalent form. Thermal decomposition products from both crude and magnesium-deprived chrome cakes were characterized by high chromium content over 50%, which occurred as eskolaite (Cr 2 O 3 ) and magnesiochromite (MgCr 2 O 4 ) crystal phases, respectively. Thermal decomposition decreased the amount of chrome cake dry feed by 90%. Based on the performed experiments, a scheme for the total control of chromium in the leather industry was designed.

  10. Combination of optical shape measurement and augmented reality for task support: II. Real-time feedback of shape measurement results

    NASA Astrophysics Data System (ADS)

    Yamauchi, Makoto; Iwamoto, Kazuyo

    2010-05-01

    Line heating is a skilled task in shipbuilding to shape the outer plates of ship hulls. Real-time information on the deformation of the plates during the task would be helpful to workers performing this process. Therefore, we herein propose an interactive scheme for supporting workers performing line heating; the system provides such information through an optical shape measurement instrument combined with an augmented reality (AR) system. The instrument was designed and fabricated so that the measured data were represented using coordinates based on fiducial markers. Since the markers were simultaneously used in the AR system for the purpose of positioning, the data could then be displayed to the workers through a head-mounted display as a virtual image overlaid on the plates. Feedback of the shape measurement results was thus performed in real time using the proposed system.

  11. NASA and ESA Collaboration on Hexavalent Chrome Free Coatings

    NASA Technical Reports Server (NTRS)

    Greene, Brian

    2017-01-01

    Presentation on the NASA and ESA Collaboration on Hexavalent Chrome Free Coatings project. Project is in response to a Memorandum of Understanding between NASA and ESA Concerning Cooperation in the Field of Space Transportation - signed September 11, 2009. The National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) have expressed mutual interest in pursuing cooperation in the areas of evaluating hexavalent chrome-free coatings, environmentally-preferable coatings for maintenance of launch facilities and ground support equipment, citric acid as an alternative to nitric acid for passivation of stainless steel alloys.

  12. GSDO Program Hexavalent Chrome Alternatives: Final Pretreatments Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt

    2013-01-01

    Hexavalent chrome free pretreatments should be considered for use on Ground Support Equipment (OSE) and Electrical Ground Support Equipment (EOSE). Both of the hexavalent chrome free pretreatments (Metalast TCP HF and SurTec 650C) evaluated by this project met, and in some instances exceeded, the requirements ofMIL-DTL-5541 "Chemical Conversion Coatings on Aluminum and Aluminum Alloys". For DC resistance measurements, both Metalast TCP HF and SurTec (!50C met initial requirements following assembly and in many cases continued to maintain passing readings for the duration of testing.

  13. The Performance of Chrome-Coated Copper as Metallic Catalytic Converter to Reduce Exhaust Gas Emissions from Spark-Ignition Engine

    NASA Astrophysics Data System (ADS)

    Warju; Harto, S. P.; Soenarto

    2018-01-01

    One of the automotive technologies to reduce exhaust gas emissions from the spark-ignition engine (SIE) is by using a catalytic converter. The aims of this research are firstly to conduct a metallic catalytic converter, secondly to find out to what extend chrome-coated copper plate (Cu+Cr) as a catalyst is efficient. To measure the concentration of carbon monoxide (CO) and hydrocarbon (HC) on the frame there are two conditions required. First is when the standard condition, and second is when Cu+Cr metallic catalytic converter is applied using exhaust gas analyzer. Exhaust gas emissions from SIE are measured by using SNI 19-7118.1-2005. The testing of CO and HC emissions were conducted with variable speed to find the trend of exhaust gas emissions from idle speed to high speed. This experiment results in the fact that the use of Cu+Cr metallic catalytic converter can reduce the production of CO and HC of a four-stroke gasoline engine. The reduction of CO and HC emission are 95,35% and 79,28%. Using active metal catalyst in form of metallic catalytic converter, it is gained an optimum effective surface of a catalyst which finally is able to decrease the amount of CO and HC emission significantly in every spinning happened in the engine. Finally, this technology can be applied to the spark ignition engine both car and motorcycle to support blue sky program in Indonesia.

  14. Safety Harness For Work Under Suspended Load

    NASA Technical Reports Server (NTRS)

    Sunoo, Su Young

    1994-01-01

    Safety device protects worker under suspended engine or other heavy load. Mechanically linked with load so if load should fall, worker yanked safely away. Worker wears chest-plate vest with straps crossing eye on back. Lower safety cable connected to eye extends horizontally away from worker to nearby wall, wrapped on pulley and extends upward to motion amplifier or reducer. Safety cables transform any sudden downward motion of overhanging load into rapid sideways motion of worker. Net catches worker, preventing worker from bumping against wall.

  15. Low-Chrome/Chrome Free Refractories for Slagging Gasifiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, J.P.; Kwong, K.-S.; Powell, C.P.

    2007-01-01

    Gasifiers are containment vessels used to react carbon-containing materials with oxygen and water, producing syngas (CO and H2) that is used in chemical and power production. It is also a potential source of H2 in a future hydrogen economy. Air cooled slagging gasifiers are one type of gasifier, operating at temperatures from 1275-1575º C and at pressures of 400 psi or higher. They typically use coal or petroleum coke as the carbon source, materials which contain ash impurities that liquefy at the gasification temperatures, producing liquid slag in quantities of 100 or more tons/day, depending on the carbon fed ratemore » and the percent ash present in the feedstock. The molten slag is corrosive to refractory linings, causing chemical dissolution and spalling. The refractory lining is composed of chrome oxide, alumina, and zirconia; and is replaced every 3-24 months. Gasifier users would like greater on-line availability and reliability of gasifier liners, something that has impacted gasifier acceptance by industry. Research is underway at NETL to improve refractory service life and to develop a no-chrome or low-chrome oxide alternative refractory liner. Over 250 samples of no- or low-chrome oxide compositions have been evaluated for slag interactions by cup testing; with potential candidates for further studies including those with ZrO2, Al2O3, and MgO materials. The development of improved liner materials is necessary if technologies such as IGCC and DOE’s Near Zero Emissions Advanced Fossil Fuel Power Plant are to be successful and move forward in the marketplace.« less

  16. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... wastewaters discharged by plants operating in all subcategories except the hair save or pulp, non-chrome tan... operating in the hair save or pulp, non-chrome tan, retan-wet finish subcategory (subpart C, see § 425.30...

  17. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... wastewaters discharged by plants operating in all subcategories except the hair save or pulp, non-chrome tan... operating in the hair save or pulp, non-chrome tan, retan-wet finish subcategory (subpart C, see § 425.30...

  18. 40 CFR 425.50 - Applicability; description of the no beamhouse subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY No... cattle hides, sheepskins, or splits (hair previously removed and pickled) into finished leather by chrome or non-chrome tanning, and retan-wet finishing. ...

  19. Survey of coatings for solar collectors. [ceramic enamels and chromium

    NASA Technical Reports Server (NTRS)

    Mcdonald, G. E.

    1974-01-01

    Ceramic enamel is found to be more solar selective, (i.e., has high solar absorptance in combination with low infrared emittance) than organic enamel, but neither is as solar selective as black chrome, black copper, black zinc, or black nickel. Ceramic enamel is matched only by black chrome in durability and wide availability. Ceramic enamel and organic enamel have approximately the same cost, and both are currently slightly lower in cost than black chrome, black copper, or black zinc. Black nickel is relatively unavailable and, because of that, realistic cost comparisons are not possible.

  20. Status of black chrome coating research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pettit, R.B.; Sowell, R.R.

    1983-01-01

    Recent results regarding the optimization of electrodeposited black chrome solar selective coatings for operation in solar collectors to temperatures up to 300/sup 0/C are summarized. Careful control of the electroplating-bath composition and special regard for bath contamination are required in order to obtain coatings that will survive daily collector operation for tens of years. An accelerated temperature aging test is presented which can be used both to estimate the coating lifetime and to monitor the coating during production. Finally, the use of sol-gel protective films to extend the lifetime of the black chrome coating is also discussed.

  1. Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene.

    PubMed

    Petis, Stephen M; Vasarhelyi, Edward M; Lanting, Brent A; Howard, James L; Naudie, Douglas D R; Somerville, Lyndsay E; McCalden, Richard W

    2016-02-01

    The choice of bearing articulation for total hip arthroplasty in younger patients is amenable to debate. We compared mid-term patient-reported outcomes and survivorship across 2 different bearing articulations in a young patient cohort. We reviewed patients with cobalt-chrome or oxidized zirconium on highly crosslinked polyethylene who were followed prospectively between 2004 and 2012. Kaplan-Meier analysis was used to determine predicted cumulative survivorship at 5 years with all-cause and aseptic revisions as the outcome. We compared patient-reported outcomes, including the Harris hip score (HHS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and Short-form 12 (SF-12) scores. A total of 622 patients were followed during the study period. Mean follow-up was 8.2 (range 2.0-10.6) years for cobalt-chrome and 7.8 (range 2.1-10.7) years for oxidized zirconium. Mean age was 54.9 ± 10.6 years for cobalt-chrome and 54.8 ± 10.7 years for oxidized zirconium. Implant survivorship was 96.0% (95% confidence interval [CI] 94.9%-97.1%) for cobalt-chrome and 98.7% (95% CI 98.0%-99.4%) for oxidized zirconium on highly crosslinked polyethylene for all-cause revisions, and 97.2% (95% CI 96.2%-98.2%) for cobalt-chrome and 99.0% (95% CI 98.4%-99.6%) for oxidized zirconium for aseptic revisions. An age-, sex- and diagnosis-matched comparison of the HHS, WOMAC and SF-12 scores demonstrated no significant changes in clinical outcomes across the groups. Both bearing surface couples demonstrated excellent mid-term survivorship and outcomes in young patient cohorts. Future analyses on wear and costs are warranted to elicit differences between the groups at long-term follow-up.

  2. Ultraviolet Curable Powder Coatings with Robotic Curing for Aerospace Applications

    DTIC Science & Technology

    2012-05-01

    millions of dollars annually on solvent- based coatings  Hexavalent chrome primer use still very widespread  Contains or requires volatile solvent...functionality can be added  Various advanced non- chrome corrosion inhibitors DISTRIBUTION A. Approved for public release; distribution unlimited. Case

  3. Analysis of Sulfidation Routes for Processing Weathered Ilmenite Concentrates Containing Impurities

    NASA Astrophysics Data System (ADS)

    Ahmad, Sazzad; Rhamdhani, M. Akbar; Pownceby, Mark I.; Bruckard, Warren J.

    Rutile is the preferred feedstock for producing high-grade TiO2 pigment but due to decreasing resources, alternative materials such as ilmenite is now used to produce a synthetic rutile (SR) feedstock. This requires removal of impurities (e.g. Fe, Mg, Mn) which, for a primary ilmenite is straightforward process. Processing of weathered ilmenite however, is complex, especially when chrome-bearing impurities are present since minor chromium downgrades the SR market value as it imparts color to the final TiO2 pigment, Chrome-bearing spinels are a problem in weathered ilmenites from the Murray Basin, Australia as their physical and chemical properties overlap with ilmenite making separation difficult. In this paper, different sulfidation process routes for weathered ilmenites are analyzed for their applicability to Murray Basin deposits as a mean of remove chrome spinel impurities. Thermodynamic and experimental studies indicated that selective sulfidation of chrome-bearing spinel can be achieved under controlled pO2 and pS2 processing conditions thereby making them amenable to separation.

  4. Start-stop testing of two self-acting air-lubricated spiral groove thrust bearing coatings

    NASA Technical Reports Server (NTRS)

    Dunfee, J. D.; Shapiro, W.

    1974-01-01

    Start-stop tests were conducted on air-lubricated spiral-groove thrust bearings. Application of a matrix-bonded molybdenum disulfide (MoS2) coating over a porous chrome oxide coating resulted in significantly lower friction, compared to bearings coated with chrome oxide only. The MoS2 coated bearing sustained 15,000 start-stop cycles at a maximum of 3600 rpm. Each cycle was 15 seconds on, 30 seconds off. The chrome oxide coated bearing failed by local welding after 2030 cycles. Both types of coatings exhibited early failures under higher thrust loads when operating films were insufficient to sustain the load without overheating.

  5. Solar Hot Water Heater

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The solar panels pictured below, mounted on a Moscow, Idaho home, are part of a domestic hot water heating system capable of providing up to 100 percent of home or small business hot water needs. Produced by Lennox Industries Inc., Marshalltown, Iowa, the panels are commercial versions of a collector co-developed by NASA. In an effort to conserve energy, NASA has installed solar collectors at a number of its own facilities and is conducting research to develop the most efficient systems. Lewis Research Center teamed with Honeywell Inc., Minneapolis, Minnesota to develop the flat plate collector shown. Key to the collector's efficiency is black chrome coating on the plate developed for use on spacecraft solar cells, the coating prevents sun heat from "reradiating," or escaping outward. The design proved the most effective heat absorber among 23 different types of collectors evaluated in a Lewis test program. The Lennox solar domestic hot water heating system has three main components: the array of collectors, a "solar module" (blue unit pictured) and a conventional water heater. A fluid-ethylene glycol and water-is circulated through the collectors to absorb solar heat. The fluid is then piped to a double-walled jacket around a water tank within the solar module.

  6. Chromosome-wide aneuploidy study (CWAS) in workers exposed to an established leukemogen, benzene

    PubMed Central

    Zhang, Luoping; Lan, Qing; Guo, Weihong; Hubbard, Alan E.; Li, Guilan; Rappaport, Stephen M.; McHale, Cliona M.; Shen, Min; Ji, Zhiying; Vermeulen, Roel; Yin, Songnian; Rothman, Nathaniel; Smith, Martyn T.

    2011-01-01

    Evidence suggests that de novo, therapy-related and benzene-induced acute myeloid leukemias (AML) occur via similar cytogenetic and genetic pathways, several of which involve aneuploidy, the loss or gain of chromosomes. Aneuploidy of specific chromosomes has been detected in benzene-related leukemia patients as well as in healthy benzene-exposed workers, suggesting that aneuploidy precedes and may be a potential mechanism underlying benzene-induced leukemia. Here, we analyzed the peripheral blood lymphocytes of 47 exposed workers and 27 unexposed controls using a novel OctoChrome fluorescence in situ hybridization (FISH) technique that simultaneously detects aneuploidy in all 24 chromosomes. Through this chromosome-wide aneuploidy study (CWAS) approach, we found heterogeneity in the monosomy and trisomy rates of the 22 autosomes when plotted against continuous benzene exposure. In addition, statistically significant, chromosome-specific increases in the rates of monosomy [5, 6, 7, 10, 16 and 19] and trisomy [5, 6, 7, 8, 10, 14, 16, 21 and 22] were found to be dose dependently associated with benzene exposure. Furthermore, significantly higher rates of monosomy and trisomy were observed in a priori defined ‘susceptible’ chromosome sets compared with all other chromosomes. Together, these findings confirm that benzene exposure is associated with specific chromosomal aneuploidies in hematopoietic cells, which suggests that such aneuploidies may play roles in benzene-induced leukemogenesis. PMID:21216845

  7. Comparison of hospital room surface disinfection using a novel ultraviolet germicidal irradiation (UVGI) generator.

    PubMed

    Jelden, Katelyn C; Gibbs, Shawn G; Smith, Philip W; Hewlett, Angela L; Iwen, Peter C; Schmid, Kendra K; Lowe, John J

    2016-09-01

    The estimated 721,800 hospital acquired infections per year in the United States have necessitated development of novel environmental decontamination technologies such as ultraviolet germicidal irradiation (UVGI). This study evaluated the efficacy of a novel, portable UVGI generator (the TORCH, ChlorDiSys Solutions, Inc., Lebanon, NJ) to disinfect surface coupons composed of plastic from a bedrail, stainless steel, chrome-plated light switch cover, and a porcelain tile that were inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE). Each surface type was placed at 6 different sites within a hospital room and treated by 10-min ultraviolet-C (UVC) exposures using the TORCH with doses ranging from 0-688 mJ/cm(2) between sites. Organism reductions were compared with untreated surface coupons as controls. Overall, UVGI significantly reduced MRSA by an average of 4.6 log10 (GSD: 1.7 log10, 77% inactivation, p < 0.0001) and VRE by an average of 3.9 log10 (GSD: 1.7 log10, 65% inactivation, p < 0.0001). MRSA on bedrail was reduced significantly (p < 0.0001) less than on other surfaces, while VRE was reduced significantly less on chrome (p = 0.0004) and stainless steel (p = 0.0012) than porcelain tile. Organisms out of direct line of sight of the UVC generator were reduced significantly less (p < 0.0001) than those directly in line of sight. UVGI was found an effective method to inactivate nosocomial pathogens on surfaces evaluated within the hospital environment in direct line of sight of UVGI treatment with variation between organism and surface types.

  8. Application of molecular simulation to investigate chrome(III)-crosslinked collagen problems

    NASA Astrophysics Data System (ADS)

    Ding, Yun-Qiao; Chen, Cheng-Lung; Gu, Qi-Rui; Liao, Jun-Min; Chuang, Po-Hsiang

    2014-04-01

    Molecular dynamics simulation with a modified CHARMM (Chemistry at Harvard Macromolecular Mechanics) force field was carried out to investigate the properties of chrome-tanned collagen in comparison with chrome-free collagen under hydrated and dehydrated conditions. An attempt has been made to explain the microcosmic origins of the various properties of the chromium(III)-crosslinked collagen. The present simulation describes the clear crosslinking topology of polychromiums to peptide chains, identifies the linking site and the capacity of the linkage, explains why the efficiency is not 100% in a practical tanning process and provides a new viewpoint on the crosslinking of the polychromium with the side chains of the collagen.

  9. NASA and ESA Collaboration on Hexavalent Chrome Alternatives: Pretreatments Only Final Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2015-01-01

    Hexavalent chromium (hex chrome or CR(VI)) is a widely used element within applied coating systems because of its self-healing and corrosion-resistant properties. The replacement of hex chrome in the processing of aluminum for aviation and aerospace applications remains a goal of great significance. Aluminum is the major manufacturing material of structures and components in the space flight arena. The National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are engaged in a collaborative effort to test and evaluate alternatives to hexavalent chromium containing corrosion coating systems. NASA and ESA share common risks related to material obsolescence associated with hexavalent chromium used in corrosion-resistant coatings.

  10. CHROME: An Approach to Teaching the Concept of Inter-Functional Cooperation in Services Organizations

    ERIC Educational Resources Information Center

    Johnson, Lester W.

    2010-01-01

    When teaching a services course (e.g., Services Marketing) it is essential that students understand that marketing/management, operations and human resource management within the service organization be fully coordinated. One useful acronym used to remind students of this need is "CHROME", standing for Communications, Human Resources,…

  11. The Record of Meteorite Infall During the Jurassic as Derived from Chrome-Spinel Grains

    NASA Astrophysics Data System (ADS)

    Caplan, C.; Huss, G. R.; Schmitz, B.; Nagashima, K.

    2017-12-01

    We study sediment-dispersed chrome-spinels in the stratigraphic record to determine how the types and amounts of meteorites falling to Earth have changed over time. The parent meteorite type of chrome-spinel grains can be determined using characteristic elemental and O-isotope compositions. In this study, we present data on grains from the Jurassic period ( 160 Ma). The Jurassic was chosen because of the possibility of discovering remnants from the breakup of the Baptistina asteroid family estimated to have occurred 160 Ma (+30, -20 Myr) (Bottke et al., 2007). Chrome-spinel grains derived from 400 kg of condensed limestone near Carcabuey, Spain were measured for their chemical compositions by electron microprobe, and their O-isotope compositions were measured by ion microprobe at the University of Hawai'i. Initial results show that 43% of the grains come from ordinary chondrites (OCs) and 18% from known types of achondrites. The remaining grains are extraterrestrial, as shown by their O-isotopes, but have not yet been classified. Some may represent material that is not currently falling on Earth. Meteorites falling on Earth today are 90.6% OCs and 7.1% achondrites. The Jurassic samples show a lower percentage of chrome-spinels from OCs (even though OCs are chrome-spinel rich). Other time periods also show meteorite abundances that are different than today. About 466 Ma there was an overwhelming influx of L-chondritic material (>99% of infalling material), due to the breakup of the L-chondrite parent body (Schmitz et al., 2001). One million years prior to the breakup, 56% of the infalling meteorites were OCs and 44% were achondrites (Heck et al., 2017). A new study suggests that 80% of the material falling in the Early Cretaceous (145-133 Ma) were from OCs and 10% were from achondrites (Schmitz et al., 2017). With just a few windows into Earth's past, we are already seeing significant changes in the mixture of materials that have fallen to Earth throughout time.

  12. Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene

    PubMed Central

    Petis, Stephen M.; Vasarhelyi, Edward M.; Lanting, Brent A.; Howard, James L.; Naudie, Douglas D.R.; Somerville, Lyndsay E.; McCalden, Richard W.

    2016-01-01

    Background The choice of bearing articulation for total hip arthroplasty in younger patients is amenable to debate. We compared mid-term patient-reported outcomes and survivorship across 2 different bearing articulations in a young patient cohort. Methods We reviewed patients with cobalt-chrome or oxidized zirconium on highly crosslinked polyethylene who were followed prospectively between 2004 and 2012. Kaplan–Meier analysis was used to determine predicted cumulative survivorship at 5 years with all-cause and aseptic revisions as the outcome. We compared patient-reported outcomes, including the Harris hip score (HHS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and Short-form 12 (SF-12) scores. Results A total of 622 patients were followed during the study period. Mean follow-up was 8.2 (range 2.0–10.6) years for cobalt-chrome and 7.8 (range 2.1–10.7) years for oxidized zirconium. Mean age was 54.9 ± 10.6 years for cobalt-chrome and 54.8 ± 10.7 years for oxidized zirconium. Implant survivorship was 96.0% (95% confidence interval [CI] 94.9%–97.1%) for cobalt-chrome and 98.7% (95% CI 98.0%–99.4%) for oxidized zirconium on highly crosslinked polyethylene for all-cause revisions, and 97.2% (95% CI 96.2%–98.2%) for cobalt-chrome and 99.0% (95% CI 98.4%–99.6%) for oxidized zirconium for aseptic revisions. An age-, sex- and diagnosis-matched comparison of the HHS, WOMAC and SF-12 scores demonstrated no significant changes in clinical outcomes across the groups. Conclusion Both bearing surface couples demonstrated excellent mid-term survivorship and outcomes in young patient cohorts. Future analyses on wear and costs are warranted to elicit differences between the groups at long-term follow-up. PMID:26812409

  13. Flight solar calibrations using the Mirror Attenuator Mosaic (MAM): Low scattering mirror

    NASA Technical Reports Server (NTRS)

    Lee, Robert B., III

    1992-01-01

    Measurements of solar radiances reflected from the mirror attenuator mosaic (MAM) were used to calibrate the shortwave portions of the Earth Radiation Budget Experiment (ERBE) thermistor bolometer scanning radiometers. The MAM is basically a low scattering mirror which has been used to attenuate and reflect solar radiation into the fields of view for the broadband shortwave (0.2 to 5 micrometers) and total (0.2 to 50.0+ micrometers) ERBE scanning radiometers. The MAM assembly consists of a tightly packed array of aluminum, 0.3175-cm diameter concave spherical mirrors and field of view limiting baffles. The spherical mirrors are masked by a copper plate, electro-plated with black chrome. Perforations (0.14 centimeter in diameter) in the copper plate serve as apertures for the mirrors. Black anodized aluminum baffles limit the MAM clear field of view to 7.1 degrees. The MAM assemblies are located on the Earth Radiation Budget Satellite (ERBS) and on the National Oceanic and Atmospheric Administration NOAA-9 and NOAA-10 spacecraft. The 1984-1985 ERBS and 1985-1986 NOAA-9 solar calibration datasets are presented. Analyses of the calibrations indicate that the MAM exhibited no detectable degradation in its reflectance properties and that the gains of the shortwave scanners did not change. The stability of the shortwave radiometers indicates that the transmission of the Suprasil W1 filters did not degrade detectably when exposed to Earth/atmosphere-reflected solar radiation.

  14. Current status of trochanteric reattachment in complex total hip arthroplasty.

    PubMed

    Barrack, Robert L; Butler, R Allen

    2005-12-01

    A study was done to determine if cable fixation devices of more recent design were associated with a higher success rate and lower incidence of complications compared with early cable devices. Beginning in 1997 a cable plate device was used in an attempt to restore abductor function more consistently in complex total hip arthroplasties. Cobalt-chrome cables through holes in a trochanteric cable plate with two or more transversely oriented cables at or below the lesser trochanter were used in order to resist migration of the trochanteric fragment better. Other component features included instrumentation that allowed provisional fixation and measurement of the tension in the cables so that cables could be tightened and retightened sequentially to insure a minimum of 80 inch-pounds of tension in all cables before final crimping. Minimum 2-year followup was obtained in 42 patients who had complex arthroplasties (trochanteric nonunions and reattachment to structural grafts) in which such a device was used. Clinical and radiographic results were compared with a series of patients with similar indications in whom wire or and earlier-generation trochanteric cable fixation devices were used. The cable plate of a more recent design was associated with a possible trend for a lower incidence of limp, use of assistive walking devices, dislocation, and abductor weakness and significant decrease in the incidence of breakage and trochanteric nonunion. Therapeutic study, Level III-1 (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.

  15. Process optimization for particle removal on blank chrome mask plates in preparation for resist application

    NASA Astrophysics Data System (ADS)

    Osborne, Stephen; Smith, Eryn; Woster, Eric; Pelayo, Anthony

    2002-03-01

    As integrated circuits require smaller lines to provide the memory and processing capability for tomorrow's marketplace, the photomask industry is adopting higher contrast resists to improve photomask lithography. Photomask yield for several high-contrast resist recipes may be improved by coating masks at the mask shop. When coating at a mask shop, an effective method is available that uses coat/bake cluster tools to ensure blanks are clean prior to coating. Many high-contrast resists are available, and some are more susceptible to time-dependent performance factors than conventional resists. One of these factors is the time between coating and writing. Although future methods may reduce the impact of this factor, one current trend is to reduce this time by coating plates at the mask shop just prior to writing. Establishing an effective process to clean blanks prior to coating is necessary for product quality control and is a new task that is critical for maskmakers who previously purchased mask plates but have decided to begin coating them within their facility. This paper provides a strategy and method to be used within coat/bake cluster tools to remove particle contamination from mask blanks. The process uses excimer-UV ionizing radiation and ozone to remove organic contaminants, and then uses a wet process combined with megasonic agitation, surfactant, and spin forces. Megasonic agitation with surfactant lifts up particles, while the convective outflow of water enhances centripetal shear without accumulating harmful charge.

  16. Total and Viable Legionella pneumophila Cells in Hot and Natural Waters as Measured by Immunofluorescence-Based Assays and Solid-Phase Cytometry ▿†

    PubMed Central

    Parthuisot, N.; Binet, M.; Touron-Bodilis, A.; Pougnard, C.; Lebaron, P.; Baudart, J.

    2011-01-01

    A new method was developed for the rapid and sensitive detection of viable Legionella pneumophila. The method combines specific immunofluorescence (IF) staining using monoclonal antibodies with a bacterial viability marker (ChemChrome V6 cellular esterase activity marker) by means of solid-phase cytometry (SPC). IF methods were applied to the detection and enumeration of both the total and viable L. pneumophila cells in water samples. The sensitivity of the IF methods coupled to SPC was 34 cells liter−1, and the reproducibility was good, with the coefficient of variation generally falling below 30%. IF methods were applied to the enumeration of total and viable L. pneumophila cells in 46 domestic hot water samples as well as in cooling tower water and natural water samples, such as thermal spring water and freshwater samples. Comparison with standard plate counts showed that (i) the total direct counts were always higher than the plate counts and (ii) the viable counts were higher than or close to the plate counts. With domestic hot waters, when the IF assay was combined with the viability test, SPC detected up to 3.4 × 103 viable but nonculturable L. pneumophila cells per liter. These direct IF methods could be a powerful tool for high-frequency monitoring of domestic hot waters or for investigating the occurrence of viable L. pneumophila in both man-made water systems and environmental water samples. PMID:21742913

  17. Effects of alpha-tocopherol addition to polymeric coatings on the UV and heat resistance of a fibrous collagen material--chrome-free leather

    USDA-ARS?s Scientific Manuscript database

    UV and heat resistance are very important qualities of leather because most leather products are constantly exposed to outdoor environments. In recent years, we have focused on using environmentally friendly antioxidants that will improve the UV and heat resistance of chrome-free leather. Tocopher...

  18. Low Temperature Powder Coating

    DTIC Science & Technology

    2011-02-09

    of volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) • Legacy primers contain hexavalent chrome • Conventional powder coatings...coatings both in laboratory and field service evaluations • LTCPC allows environmental cost reductions through VOC/HAP elimination and hexavalent ... chrome reduction. • The LTCPC process greatly shortens the coating operation (LTCPC cures much more rapidly then conventional wet coatings) resulting in

  19. Modified microplate method for rapid and efficient estimation of siderophore produced by bacteria.

    PubMed

    Arora, Naveen Kumar; Verma, Maya

    2017-12-01

    In this study, siderophore production by various bacteria amongst the plant-growth-promoting rhizobacteria was quantified by a rapid and efficient method. In total, 23 siderophore-producing bacterial isolates/strains were taken to estimate their siderophore-producing ability by the standard method (chrome azurol sulphonate assay) as well as 96 well microplate method. Production of siderophore was estimated in percent siderophore unit by both the methods. It was observed that data obtained by both methods correlated positively with each other proving the correctness of microplate method. By the modified microplate method, siderophore production by several bacterial strains can be estimated both qualitatively and quantitatively at one go, saving time, chemicals, making it very less tedious, and also being cheaper in comparison with the method currently in use. The modified microtiter plate method as proposed here makes it far easier to screen the plant-growth-promoting character of plant-associated bacteria.

  20. Structural and optical properties of copper-coated substrates for solar thermal absorbers

    NASA Astrophysics Data System (ADS)

    Pratesi, Stefano; De Lucia, Maurizio; Meucci, Marco; Sani, Elisa

    2016-10-01

    Spectral selectivity, i.e. merging a high absorbance at sunlight wavelengths to a low emittance at the wavelengths of thermal spectrum, is a key characteristics for materials to be used for solar thermal receivers. It is known that spectrally selective absorbers can raise the receiver efficiency for all solar thermal technologies. Tubular sunlight receivers for parabolic trough collector (PTC) systems can be improved by the use of spectrally selective coatings. Their absorbance is increased by deposing black films, while the thermal emittance is minimized by the use of properly-prepared substrates. In this work we describe the intermediate step in the fabrication of black-chrome coated solar absorbers, namely the fabrication and characterization of copper coatings on previously nickel-plated stainless steel substrates. We investigate the copper surface features and optical properties, correlating them to the coating thickness and to the deposition process, in the perspective to assess optimal conditions for solar absorber applications.

  1. NERVA materials development

    NASA Technical Reports Server (NTRS)

    Mandell, B.

    1970-01-01

    Materials development topics include: development of analysis techniques to adjust heterogeneous data; determination of thermal conductivity for AISI 347 stainless steel and elastic moduli and Poisson's ratio for Inconel 718 and Ti 5Al-2.5Sn; embrittlement effects of 1400 psi gaseous hydrogen for alloy 718 and Ti 5Al-2.5Sn; cryogenic radiation damage of Ti 5Al-2.5Sn; and evaluation of prepreg, impregnation, and fabric materials for optimum fibrous graphite properties. Component support topics include: tensile design allowable development of Ti 5Al-2.5Sn for turbopump applications; evaluation of fatigue, fracture toughness, and stress corrosion properties of AA 7039-T63 for pressure vessel applications; development of AISI 347 sheet tensile and creep properties for nozzle applications; evaluation of orbital weld techniques for aluminum line fabrication; material selection of shield materials; development of high load friction and wear properties of hard chrome/gold plate combinations; and evaluation of weld processes for NASS duct coolant channel fabrication.

  2. KSC-05PD-0527

    NASA Technical Reports Server (NTRS)

    2005-01-01

    KENNEDY SPACE CENTER, FLA. In the Vehicle Assembly Building at NASAs Kennedy Space Center, workers mate the External Tank, at left, to the underside of Space Shuttle Discovery, at right. Each of two aft external tank umbilical plates mate with a corresponding plate on the orbiter. The plates help maintain alignment among the umbilicals. The attach fitting is aft of the nose gear wheel well. Workers next will perform an electrical and mechanical verification of the mated interfaces to verify all critical vehicle connections. A Shuttle interface test is performed using the launch processing system to verify Space Shuttle vehicle interfaces and Space Shuttle vehicle-to-ground interfaces. In approximately one week, Space Shuttle Discovery will be ready for rollout to Launch Pad 39B for Return to Flight mission STS-114. The launch window for STS-114 is May 15 to June 3.

  3. 40 CFR 425.30 - Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Applicability; description of the hair save or pulp, non-chrome tan, retan-wet finish subcategory. 425.30 Section 425.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save...

  4. A useful single-solution polychrome stain for plant material...Brook Cyte-Chrome I.

    Treesearch

    Stanley L Krugman; Julia F. Littlefield

    1968-01-01

    Fresh and chemically fixed sectioned plant material can be quickly stained by applying a Brook Cyte Chrome I polychrome stain. Staining time averaged only about 10 minutes. And exact timing of staining and de-staining is not as critical as with most of the commonly used stains. The overall quality is comparable to that of the traditional stains.

  5. Development of advanced thermoelectric materials, phase A

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Work performed on the chemical system characterized by chrome sulfide, chrome selenide, lanthanum selenide, and lanthanum sulfide is described. Most materials within the chemical systems possess the requisites for attractive thermoelectric materials. The preparation of the alloys is discussed. Graphs show the Seebeck coefficient, electrical resistivity, and thermal conductivity of various materials within the chemical systems. The results of selected doping are included.

  6. Fleet Readiness Center - Southeast Technology Development Program (Cadmium & Hexavalent Chromium Reduction)

    DTIC Science & Technology

    2014-11-01

    Industrial Waste Water Treatment  Aircraft & Component Paint Removal (ABM & Chemical)  Chrome Electroplating  Corrosion Treatment  Aircraft...Hex Chrome post treatment )  Energy Use; Electrical (& Steam)  NDI- Florescent Penetrant  Solvent Tank Cleaning  Water (& Sanitary) Use...Engineer Corrosion Science & Engineering NAVAIR Jacksonville Phone: (904) 790-6405 Email: john.benfer@navy.mil ASETS Technical Workshop (NOV

  7. Evaluation of Advanced Solid Lubricant Coatings for Foil Air Bearings Operating at 25 and 500 C

    NASA Technical Reports Server (NTRS)

    DellaCorte, Christopher; Fellenstein, James A.; Benoy, Patricia A.

    1998-01-01

    The tribological properties of one chrome oxide and one chrome carbide based solid lubricant coating were evaluated in a partial-arc foil bearing at 25 and 500 C. Start/stop bearing operation up to 20,000 cycles were run under 10 kPa (1.5 psi) static deadweight load. Bearing friction (torque) was measured during the test. Specimen wear and SEM/EDS surface analyses were conducted after testing to understand and elucidate the tribological characteristics observed. The chrome oxide coating which contains both (Ag) and (BaF2/CaF2) for low and high temperature lubrication, exhibited low friction in sliding against Al2O3 coated foils at 25 and 500 C. The chrome carbide coating, which lacked a low temperature lubricant but contained BaF2/CaF2 as a high temperature lubricant, exhibited high friction at 25 C and low friction at 500 C against both bare and Al2O3 coated superalloy foil surfaces. Post test surface analyses suggest that improved tribological performance is exhibited when a lubricant film from the coating transfers to the foil surface.

  8. Green chemistry approaches to leather tanning process for making chrome-free leather by unnatural amino acids.

    PubMed

    Krishnamoorthy, G; Sadulla, S; Sehgal, P K; Mandal, Asit Baran

    2012-05-15

    In the present study, green and sustainable method or eco-friendly approaches to tanning process based on unnatural D-amino acids (D-AA)-aldehyde (Ald) as a substitute for chrome-free tanning has been attempted. The distribution of optically active D-AA in tanned leather, the hydrothermal stability, the mechanical properties and resistance to collagenolytic activity of tanned leather, the evaluation of eco-friendly characteristics were investigated. Scanning electron microscopic (SEM) and Atomic force microscopic (AFM) analyses indicate the surface morphology and roughness, respectively, of the tanned leather collagen matrix. Shrinkage and Differential scanning calorimetric (DSC) analyses shows that the shrinkage temperature (T(s)) and denaturation temperature (T(d)) of tanned leather are related to the content of D-AA+Ald present in the leather matrix. It has been found that the T(s) of D-AA tanned leather is more than that of Ald tanned leather and also more or less equal to chrome tanned leather. Environmental impact assessment (EIA) shows that the developed process results in significant reduction in total solids content (TSC) and improves better biodegradability of organic compound present in the effluent compared to chrome tanning. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Advanced mask cleaning for 0.20-μm technology: an integrated user-supplier approach

    NASA Astrophysics Data System (ADS)

    Poschenrieder, Rudolf; Hay, Bernd; Beier, Matthias; Hourd, Andrew C.; Stuemer, Harald; Gairing, Thomas M.

    1998-12-01

    A newly developed photomask final cleaning system, STEAG HamaTech's Advanced Single Substrate Cleaner, ASC 500, was assessed and optimized at the Siemens mask shop in Munich, Germany, under production conditions within the Esprit European Semiconductor Equipment Assessment programme (SEA). The project was carried out together with the active participation of Compugraphics Intl. Ltd. (UK), DuPont Photomasks, Inc. (Germany; Photronics-MZD, Germany). The results of the assessment are presented, focusing on the cleaning performance at the 0.25 micrometer defect level on photomasks, equipment reliability and Cost of Ownership data. A reticle free of soft defects on glass and on chrome down to the 0.25 micrometer level requires an excellent cleaning process and the use of high-end inspection tools like the KLA STARlight. In order to get a full understanding of the nature of the detected features additional investigations on the blank quality have been carried out. These investigations include the questions whether a detection is a hard or a soft defect and whether small defects on chrome are able to move on the reticle surface. Final cleaning recipes have been optimized in respect to cleaning efficiency while maintaining high throughput and low Cost of Ownership. A benchmark comparison against other final cleaning tools at the partner's maskshops showed the leading data of the ASC 500. It was found that a cleaning program which includes several substrate flips and a combination of the available cleaning methods acid- dispense, water pressure jet clean, brush and megasonic clean was best suitable to achieve these goals. In particular the use of the brush unit was shown to improve the yield while not adding damage to the plate.

  10. Mineralogy and geochemistry of two metamorphosed sedimentary manganese deposits, Sierra Nevada, California, USA

    USGS Publications Warehouse

    Flohr, M.J.K.; Huebner, J.S.

    1992-01-01

    Laminated to massive rhodochrosite, hausmannite, and Mn-silicates from the Smith prospect and Manga-Chrome mine, Sierra Nevada, California were deposited as ocean floor sediments associated with chert and shale. The principal lithologies at Smith are chert, argillite, rhodochrosite-, hausmannite- and chlorite-rich layers, and relatively uncommon layers of jacobsite. The Manga-Chrome mine also contains layers rich in manganoan calcite and caryopilite. Tephroite, rhodonite, spessartine, and accessory alleghanyite and sonolite formed during metamorphism. Volcaniclastic components are present at Manga-Chrome as metavolcanic clasts and as Mn-poor, red, garnet- and hematite-rich layers. There is no evidence, such as relict lithologies, that Mn was introduced into Mn-poor lithologies such as chert, limestone or mudstone. Replacement of Mn-poor phases by Mn-rich phases is observed only in the groundmass of volcanic clasts that appear to have fallen into soft Mn-rich mud. Manganiferous samples from the Smith prospect and Manga-Chrome mine have high Mn Fe and low concentrations of Ni, Cu, Zn, Co, U, Th and the rare-earth elements that are similar to concentrations reported from other ancient Mn deposits found in chert-greenstone complexes and from manganiferous sediments and crusts that are forming near modern sea floor vents. The Sierra Nevada deposits formed as precipitates of Mn-rich sediments on the sea floor, probably from mixtures of circulating hydrothermal fluids and seawater. The composition of a metabasalt from the Smith prospect is consistent with those of island-arc tholeiites. Metavolcanic clasts from the Manga-Chrome mine are compositionally distinct from the Smith metabasalt and have alkaline to calc-alkaline affinities. A back-arc basin is considered to be the most likely paleoenvironment for the formation of the Mn-rich lenses at the Manga-Chrome mine and, by association, the Smith prospect. Layers of rhodochrosite, hausmannite and chert preserve the composition and some textures of the sedimentary protoliths at both Sierra Nevada deposits. Jacobsite-rich layers probably represent a Fe-rich protolith. Caryopilite and manganoan calcite represent additional protoliths at the Manga-Chrome mine. The metamorphic assemblage prehnite-chlorite-epidote-calcite in a metabasalt from the Smith prospect constrains regional metamorphic conditions to a maximum temperature of 325??C and a pressure of 2 kbar. Slightly higher temperatures are indicated by the presence of actinolite in another metabasalt. Compositions of Mn-rich minerals in Smith samples are consistent with these metamorphic conditions. ?? 1992.

  11. Vapor pressure and evaporation rate of certain heat-resistant compounds in a vacuum at high temperatures

    NASA Technical Reports Server (NTRS)

    Bolgar, A. S.; Verkhoglyadova, T. S.; Samsonov, G. V.

    1985-01-01

    The vapor pressure and evaporation rate of borides of titanium, zirconium, and chrome; and of strontium and carbides of titanium, zirconium, and chrome, molybdenum silicide; and nitrides of titanium, niobium, and tantalum in a vacuum were studied. It is concluded that all subject compounds evaporate by molecular structures except AlB sub 12' which dissociates, losing the aluminum.

  12. Consolidation of Surface Coatings by Friction Stir Techniques

    DTIC Science & Technology

    2010-09-01

    alloy samples were plasma sprayed with a Titanium-Nickel-Chrome coating or a Titanium coating. Single and multiple pass experiments were performed...based coatings onto the Aluminum alloy surface. Results showed that the most successful results were accomplished using a flat, pinless tool, with...properties. Aluminum alloy samples were plasma sprayed with a Titanium-Nickel-Chrome coating or a Titanium coating. Single and multiple pass experiments

  13. USMC Environmental and Corrosion Control Issues

    DTIC Science & Technology

    2010-12-01

    b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Minimizing Hexavalent Chromium ...cadmium – Use of hexavalent chromium – Potential incompatibilities with alternatives – Use of non-corrosion resistant hardware in harsh...on non-chrome and trivalent -chrome alternatives • Favor non-cadmium hardware • Concern with logistics and supply chain of many alternatives Pre

  14. New PVD Technologies for New Ordnance Coatings

    DTIC Science & Technology

    2012-04-01

    characteristics using a Tantalum and a Chrome target; 4) Deposition of Ta coatings and reactive deposition of CrN; 5) Deposition parameters affecting film...Vapor Deposition (PVD); High Power Impulse Magnetron Sputtering (HIPIMS); Modulated Pulsed Power (MPP); Tantalum; Chrome ; Ta coatings; CrN; coating...The pre-production chemicals and acids are hazardous and hexavalent Cr is a known carcinogen. Significant annual expenditures are necessary to

  15. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    PubMed Central

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These preliminary findings showed that PEEK-OPTIMA™ gives promise as an alternative bearing material to cobalt chrome alloy in the femoral component of a total knee replacement with respect to wear performance. PMID:27637723

  16. Evaluation of attenuated PSM photomask blanks with TF11 chrome and FEP-171 resist on a 248 nm DUV laser pattern generator

    NASA Astrophysics Data System (ADS)

    Xing, Kezhao; Björnborg, Charles; Karlsson, Henrik; Paulsson, Adisa; Rosendahl, Anna; Beiming, Peter; Vedenpää, Jukka; Walford, Jonathan; Newman, Tom

    2007-10-01

    Tighter requirements on mask resolution, CD and image positioning accuracy at and beyond the 45 nm technology node push the development of improved photomask blanks. One such blank for attenuated phase-shift masks (att-PSM) provides a thinner chrome film, named TF11, with higher chrome etch rate compared to the previous generation Att- PSM blank (NTAR5 chrome film) from the same supplier. Reduced stress in the chrome film also results in less image placement error induced by the material. FEP-171 is the positive chemically amplified resist (PCAR) that is most commonly used in advanced mask manufacturing with both 50 keV variable shaped e-beam (VSB) and DUV laser pattern generators. TF11 allows an FEP-171 resist film down to about 2000 Å thickness with sufficient etch resistance, while the standard resist thickness for NTAR5 is around 3000 Å. This work has experimentally evaluated the use of TF11 chrome and FEP-171 resist together with a 248 nm DUV laser pattern generator, the Sigma7500. First, patterning performance in resist with thicknesses from 2000 Å to 2600 Å, in steps of 100 Å, was tested with respect to swing curve and basic lithographic parameters including resolution, CD linearity, CD iso-dense bias and dose sensitivity. Patterning results on mask showed a swing minimum at around 2200 Å and a swing maximum at around 2500 Å, which correspond to reflectivity measurements for 248 nm wavelength performed by the blank supplier. It was concluded that the overall patterning performance was best close to the swing maximum. Thereafter the patterning performance using TF11 at two resist thicknesses, 2000 Å and 2550 Å, was studied in more detail and compared to performance using NTAR5 with 3200 Å resist. The evaluation showed that the Sigma7500-II offers good compatibility with TF11, especially using the optimized FEP-171 resist thickness of 2550 Å. It also showed that the patterning capability of the Sigma7500-II using TF11 and 2550 Å resist is improved compared to using NTAR5 and 3200 Å resist.

  17. In-depth survey report of American Airlines plating facility

    NASA Astrophysics Data System (ADS)

    Mortimer, V. D., Jr.

    1982-12-01

    An in depth survey was conducted at the American Airlines Maintenance and Engineering Center as part of National Institute for Occupational Safety and Health (NIOSH) study evaluating measures to control occupational health hazards associated with the metal plating industry. This American Airlines plating facility, employing approximately 25 workers, is primarily engaged in plating hard chromium, nickel and cadmium on aircraft engine and landing gear parts. Six tanks were studied, including an electroless nickel tank. Area and personal samples for chromium, nickel, cadmium, and cyanide were collected. Ventilation airflow and tank dimensions were measured and data recorded on plating operations. The relationships between air contaminants emitted, local exhaust ventilation flow rate, tank size, and plating activity were evaluated.

  18. High pressure furnace

    DOEpatents

    Morris, Donald E.

    1993-01-01

    A high temperature high pressure furnace has a hybrid partially externally heated construction. A metallic vessel fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized (the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum). The disclosed alloy is fabricated into 11/4 or 2 inch, 32 mm or 50 mm bar stock and has a length of about 22 inches, 56 cm. This bar stock has an aperture formed therein to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the vessel is provided with a small blind aperture into which a thermocouple can be inserted. The closed end of the vessel is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior.

  19. Separation of motor oils, oily wastes and hydrocarbons from contaminated water by sorption on chrome shavings.

    PubMed

    Gammoun, A; Tahiri, S; Albizane, A; Azzi, M; Moros, J; Garrigues, S; de la Guardia, M

    2007-06-25

    In this paper, the ability of chrome shavings to remove motor oils, oily wastes and hydrocarbons from water has been studied. To determine amount of hydrocarbons sorbed on tanned wastes, a FT-NIR methodology was used and a multivariate calibration based on partial least squares (PLS) was employed for data treatment. The light density, porous tanned waste granules float on the surface of water and remove hydrocarbons and oil films. Wastes fibers from tannery industry have high sorption capacity. These tanned solid wastes are capable of absorbing many times their weight in oil or hydrocarbons (6.5-7.6g of oil and 6.3g of hydrocarbons per gram of chrome shavings). The removal efficiency of the pollutants from water is complete. The sorption of pollutants is a quasi-instantaneous process.

  20. Service Test Plan for A-10 Hydraulic Actuators

    DTIC Science & Technology

    2014-05-29

    utilizes electroplated chrome as a wear coating on the actuator assembly. This actuator will be delta-qualified while two other actuators will be qualified...2730534-1 Similarity to (1) 3 Elevator Actuator Hydraulic Flight Control System 2730551-5 Similarity to (1) The current chrome electroplating ...process has been proven to be a significant health hazard, and it is anticipated that future Government regulation will make the use of electroplated

  1. Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion Coatings for Steel Substrates (Briefing Charts)

    DTIC Science & Technology

    2011-02-01

    UNCLASSIFIED: Approved for public release; distribution unlimited. Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion...00-00-2011 4. TITLE AND SUBTITLE Laboratory Validation and Demonstrations of Non-Hexavalent Chromium Conversion Coatings for Steel Substrates 5a...Coatings for HHA • SurTec 650 - ChromitAL TCP - Trivalent Chrome Pretreatment Developed by NAVAIR for Aluminum. • Chemetall Oxsilan 9810/2 - Non-chrome

  2. Project SQUID. Quarterly Progress Report

    DTIC Science & Technology

    1948-04-01

    connection with temperature measurements we are investigating the infrared emission of the pulse jet. We have a lead sulphide cell which, when...formed on an 11% chrome-iron alloy when oxidized in oxygen at a pressure of one millimeter of mercury (sumnarized in the Annual Report, 1947) show...work has been obtained recently. 36 TABLE I Surface Structures Formed on a 27% Chrome-Iron Oxidized in Dry Oxygen at One Millimeter Mercury

  3. Development of advanced thermoelectric materials

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The development of an advanced thermoelectric material for radioisotope thermoelectric generator (RTG) applications is reported. A number of materials were explored. The bulk of the effort, however, was devoted to improving silicon germanium alloys by the addition of gallium phosphide, the synthesis and evaluation of lanthanum chrome sulfide and the formulation of various mixtures of lanthanum sulfide and chrome sulfide. It is found that each of these materials exhibits promise as a thermoelectric material.

  4. Improvement of the Corrosion Resistance of Turbine Engine Bearings

    DTIC Science & Technology

    1986-04-01

    high chrome martensitic steels . Studies conducted in the past several years (References 6 and 7) have shown that high-chrome stainless steels ...qualification procedures required for production use of powder metallurgy bearings may exceed the 3- to 5-year introduction goal. Another stainless steel ...addition, these alloys are commercially available in wrought form as is the currently used VIM-VAR M50. A common high car!.on stainless steel , AISI 440C is

  5. Chrome - Free Aluminum Coating System

    NASA Technical Reports Server (NTRS)

    Bailey, John H.; Gugel, Jeffrey D.

    2010-01-01

    This slide presentation concerns the program to qualify a chrome free coating for aluminum. The program was required due to findings by OSHA and EPA, that hexavalent chromium, used to mitigate corrosion in aerospace aluminum alloys, poses hazards for personnel. This qualification consisted of over 4,000 tests. The tests revealed that a move away from Cr+6, required a system rather than individual components and that the maximum corrosion protection required pretreatment, primer and topcoat.

  6. High pressure oxygen furnace

    DOEpatents

    Morris, D.E.

    1992-07-14

    A high temperature high pressure oxygen furnace having a hybrid partially externally heated construction is disclosed. A metallic bar fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized, the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum). The disclosed alloy is fabricated into 11/4 inch bar stock and has a length of about 17 inches. This bar stock is gun drilled for over 16 inches of its length with 0.400 inch aperture to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the bar is provided with a small support aperture into which both a support and a thermocouple can be inserted. The closed end of the gun drilled bar is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior. 5 figs.

  7. High pressure oxygen furnace

    DOEpatents

    Morris, Donald E.

    1992-01-01

    A high temperature high pressure oxygen furnace having a hybrid partially externally heated construction is disclosed. A metallic bar fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized (the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum). The disclosed alloy is fabricated into 11/4 inch bar stock and has a length of about 17 inches. This bar stock is gun drilled for over 16 inches of its length with 0.400 inch aperture to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the bar is provided with a small support aperture into which both a support and a thermocouple can be inserted. The closed end of the gun drilled bar is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior.

  8. High pressure furnace

    DOEpatents

    Morris, D.E.

    1993-09-14

    A high temperature high pressure furnace has a hybrid partially externally heated construction. A metallic vessel fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized (the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum)). The disclosed alloy is fabricated into 11/4 or 2 inch, 32 mm or 50 mm bar stock and has a length of about 22 inches, 56 cm. This bar stock has an aperture formed therein to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the vessel is provided with a small blind aperture into which a thermocouple can be inserted. The closed end of the vessel is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior. 19 figures.

  9. NASA TEERM Hexavalent Chrome Alternatives Projects

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt; Rothgeb, Matt

    2011-01-01

    This slide presentation reviews the NASA project to select an alternative to hexavalent chrome in the aerospace industry. Included is a recent historic testing and research that the Agency has performed on (1) the external tank, (2) the shuttle orbiter, (3) the Shuttle Rocket Booster, and (4) the Space Shuttle Main Engine. Other related Technology Evaluation for Environmental Risk Mitigation (TEERM) projects are reviewed. The Phase I process of the project performed testing of alternatives the results are shown in a chart for different coating systems. International collaboration was also reviewed. Phase II involves further testing of pretreatment and primers for 6 and 12 months of exposure to conditions at Launch Pad and the beach. Further test were performed to characterize the life cycle corrosion of the space vehicles. A new task is described as a joint project with the Department of Defense to identify a Hex Chrome Free Coatings for Electronics.

  10. An Analysis of Army Hazardous Waste Disposal Cost Data

    DTIC Science & Technology

    1991-04-01

    be contaminated with gl EP Toxic (but not limited to) chromium 2133 Sludge, may be contaminated with (but not lb EP Toxic limited to) trivalent ...limited to) trivalent chrome, cadmium, heavy metals and metals continued - ’kg = kilograms 18 Table 6 (Cont’d) CLIN Supplies/Services CLIN (kg) % of...2.0 0600 Compressed gas cylinders, misc. 81,566 1.8 2133 Sludge, may be contaminated with (but not 78,000 1.7 limited to) trivalent chrome, cadmium

  11. Study of bacterial flora associated with mobile phones of healthcare workers and non-healthcare workers.

    PubMed

    Morubagal, Raghavendra Rao; Shivappa, Sowmya Govindanahalli; Mahale, Rashmi Padmanabha; Neelambike, Sumana Mhadevaiah

    2017-06-01

    Despite improvements in modern diagnosis and therapies, hospital acquired infections remain a leading problem of global health systems. Healthcare workers mobile phones is a reservoir for potential pathogens. Despite the high possibility of being contaminated, mobile phones are rarely clean and are often touched during or after examination of patients and handling of specimens without proper hand washing. The main objective of the present study was to isolate, identify different types of bacteria and their antibiotic sensitivity from mobile phones of healthcare workers and non-health-care workers. Samples were collected aseptically by rolling over the exposed surfaces of the mobile phones inoculated on the agar plates and incubated aerobically. After incubation, plates were examined for growth. Bacteria were identified and antibiotic sensitivity was tested as per standard microbiological procedures. In this study a total of 175 samples were examined, out of which 125 samples were from healthcare workers (HCWs), 50 samples were from non-healthcare workers (non-HCWs). Among the mobile phones of HCW's from ICUs, Acinetobacter baumannii (36.84%) was the predominant organism isolated followed by methicillin resistant Staphylococcus aureus (MRSA) (21.05%). Predominant organism isolated from HCW's in operation theater theater was MRSA (46.66%). Out of 50 worker's non-HCWs mobile phones samples cultured, 23 (46.00%) samples yielded growth of six different types of bacteria. Our study reveals that there is definite colonization of bacteria on mobile phones of the HCWs. It is not only capable of transferring message but also disease-producing microbes. In order to reduce incidence of nosocomial infections, there should be implementation of hand washing practices and regulations around the use of mobile telephones in hospital settings.

  12. Trace elements and diabetes: Assessment of levels in tears and serum.

    PubMed

    Cancarini, A; Fostinelli, J; Napoli, L; Gilberti, M E; Apostoli, P; Semeraro, F

    2017-01-01

    Tear film is critical for the well-being and homeostasis of the ocular surface. Although the composition of the tear film is well known, the composition of metallic elements have yet to be analysed. Despite trace elements metabolism has been reported to play a role in the pathogenesis of diabetes mellitus, a metabolic disease that affects several aspects of homeostasis, little is known in the literature regarding concentration and possible variation of metallic elements in tear film. We studied the concentrations of several essential and non-essential metallic elements in the tear fluid and serum of patients with type II diabetes mellitus and a group of non-diabetic controls. Serum and tear fluid were collected from 97 patients: 47 type II diabetic patients and 50 non-diabetic controls. Regarding tear film, there were statistically significant differences in Zinc, Chrome, Cobalt, Manganese, Barium, and Lead between groups; the values of all metallic elements were found to be statistically significant higher in patients with mellitus type II diabetes. Regarding serum values there was a statistically significant difference in Chrome, Cobalt, and Selenium values; the concentrations of Chrome and Cobalt were higher in the control group, while Selenium concentration was higher in diabetic patients. In patients with type II diabetes, metal elements with higher concentrations in tears compared to serum were: Lead, Barium, Manganese, Cobalt, and Chrome. In the control group, the metal elements with the highest concentration in tear film compared to serum were Chrome, Manganese, Barium, and Lead. In this study, we attempted to evaluate the possible effect of a disease, such as diabetes, on the metabolism of metallic elements. Although our evidence was very interesting, it is probably limited in its accuracy due to the fact that individuals in the control group harboured ocular pathologies. This work lays the foundation for future studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. The constraint method: A new finite element technique. [applied to static and dynamic loads on plates

    NASA Technical Reports Server (NTRS)

    Tsai, C.; Szabo, B. A.

    1973-01-01

    An approch to the finite element method which utilizes families of conforming finite elements based on complete polynomials is presented. Finite element approximations based on this method converge with respect to progressively reduced element sizes as well as with respect to progressively increasing orders of approximation. Numerical results of static and dynamic applications of plates are presented to demonstrate the efficiency of the method. Comparisons are made with plate elements in NASTRAN and the high-precision plate element developed by Cowper and his co-workers. Some considerations are given to implementation of the constraint method into general purpose computer programs such as NASTRAN.

  14. Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces.

    PubMed

    Jones, V C; Barton, D C; Auger, D D; Hardaker, C; Stone, M H; Fisher, J

    2001-01-01

    A multidirectional pin-on-plate reciprocating machine was used to compare the wear performance of UHMWPE sliding against cast cobalt chrome (CoCr) plates that were either untreated or coated with Amorphous Diamond Like Carbon (ADLC). The test conditions were based on a 1/5 scale model representative of in vivo motion at the tibial counterfaces of unconstrained mobile bearing knees. The average +/- STERR wear rates were 13.78+/-1.06 mm3/Mcycles for the ADLC counterfaces and 0.504+/-0.12 mm3/Mcycles for the control CoCr counterfaces. All of the pins run on the ADLC counterfaces exhibited the same patterns of blistering along the central axis, and severe abrasion elsewhere to the extent that all of the original machining marks were removed after just one week of testing. The average value of friction coefficient was 0.24 for the ADLC counterfaces and 0.073 for the control CoCr counterfaces. The factor of 3.5 increase was statistically significant at p < 0.05. In the tribological evaluation of ADLC coatings for tibial trays in mobile bearing knees, this study shows that this specific Physical Vapour Deposition (PVD) ADLC showed significantly poorer frictional and wear performance than uncoated surfaces which was sufficient to negate any potential benefits of improved resistance to third body damage.

  15. A new method for registration of heterogeneous sensors in a dimensional measurement system

    NASA Astrophysics Data System (ADS)

    Zhao, Yan; Wang, Zhong; Fu, Luhua; Qu, Xinghua; Zhang, Heng; Liu, Changjie

    2017-10-01

    Registration of multiple sensors is a basic step in multi-sensor dimensional or coordinate measuring systems before any measurement. In most cases, a common standard is used to be measured by all sensors, and this may work well for general registration of multiple homogeneous sensors. However, when inhomogeneous sensors detect a common standard, it is usually very difficult to obtain the same information, because of the different working principles of the sensors. In this paper, a new method called multiple steps registration is proposed to register two sensors: a video camera sensor (VCS) and a tactile probe sensor (TPS). In this method, the two sensors measure two separated standards: a chrome circle on a reticle and a reference sphere with a constant distance between them, fixed on a steel plate. The VCS captures only the circle and the TPS touches only the sphere. Both simulations and real experiments demonstrate that the proposed method is robust and accurate in the registration of multiple inhomogeneous sensors in a dimensional measurement system.

  16. Removal of hexavalent chromium from wastewater using a new composite chitosan biosorbent.

    PubMed

    Boddu, Veera M; Abburi, Krishnaiah; Talbott, Jonathan L; Smith, Edgar D

    2003-10-01

    A new composite chitosan biosorbent was prepared by coating chitosan, a glucosamine biopolymer, onto ceramic alumina. The composite bioadsorbent was characterized by high-temperature pyrolysis, porosimetry, scanning electron microscopy, and X-ray photoelectron spectroscopy. Batch isothermal equilibrium and continuous column adsorption experiments were conducted at 25 degrees C to evaluate the biosorbent for the removal of hexavalent chromium from synthetic as well as field samples obtained from chrome plating facilities. The effect of pH, sulfate, and chloride ion on adsorption was also investigated. The biosorbent loaded with Cr(VI) was regenerated using 0.1 M sodium hydroxide solution. A comparison of the results of the present investigation with those reported in the literature showed that chitosan coated on alumina exhibits greater adsorption capacity for chromium(VI). Further, experimental equilibrium data were fitted to Langmuir and Freundlich adsorption isotherms, and values of the parameters of the isotherms are reported. The ultimate capacity obtained from the Langmuir model is 153.85 mg/g chitosan.

  17. Two fold modified chitosan for enhanced adsorption of hexavalent chromium from simulated wastewater and industrial effluents.

    PubMed

    Kahu, S S; Shekhawat, A; Saravanan, D; Jugade, R M

    2016-08-01

    Ionic solid (Ethylhexadecyldimethylammoniumbromide) impregnated phosphated chitosan (ISPC) was synthesized and applied for enhanced adsorption of hexavalent chromium from industrial effluent. The compound obtained was extensively characterized using instrumental techniques like FT-IR, TGA-DTA, XRD, SEM, BET and EDX. ISPC showed high adsorption capacity of 266.67mg/g in accordance with Langmuir isotherm model at pH 3.0 due to the presence of multiple sites which contribute for ion pair and electrostatic interactions with Cr(VI) species. The sorption kinetics and thermodynamic studies revealed that adsorption of Cr(VI) followed pseudo-second-order kinetics with exothermic and spontaneous behaviour. Applicability of ISPC for higher sample volumes was discerned through column studies. The real chrome plating industry effluent was effectively treated with total chromium recovery of 94%. The used ISPC was regenerated simply by dilute ammonium hydroxide treatment and tested for ten adsorption-desorption cycles with marginal decrease in adsorption efficiency. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Mechanical properties of Cr-Cu coatings produced by electroplating

    NASA Astrophysics Data System (ADS)

    Riyadi, Tri Widodo Besar; Sarjito, Masyrukan, Riswan, Ricky Ary

    2017-06-01

    Hard chromium coatings has long been considered as the most used electrodeposited coating in several industrial applications such as in petrochemistry, oil and gas industries. When hard coatings used in fastener components, the sliding contact during fastening operation produces high tensile stresses on the surface which can generate microcracks. For component used in high oxidation and corrosion environment, deep cracks cannot be tolerated. In this work, a laminated structure of Cr-Cu coating was prepared using electroplating on carbon steel substrates. Two baths of chrome and copper electrolyte solutions were prepared to deposit Cr as the first layer and Cu as the second layer. The effect of current voltages on the thickness, hardness and specific wear rate of the Cu layer was investigated. The results show that an increase of the current voltages increased the thickness and hardness of the Cu layer, but reduced the specific wear rate. This study showed that the use of Cu can be a potential candidate as a laminated structure Cr-Cu for chromium plating.

  19. Strengthening DoD Cyber Security with the Vulnerability Market

    DTIC Science & Technology

    2014-01-01

    50,000 – $100,000 Windows $60,000 – $120,000 Firefox or Safari $60,000 – $150,000 Chrome or Internet Explorer $80,000 – $200,000 iOS $100,000...the CTB metric for the Google Chrome OS at $110,000. Accordingly, this metric could be used by Google to compare its security to other operating...Mozilla Foundation. (n.d.). Mozilla. Retrieved from https://www.mozilla. org/en-US/foundation/ Thomson, I. (2013, March 8). Pwn2Own: IE10, Firefox

  20. Nanoscale investigation of the degradation mechanism of a historical chrome yellow paint by quantitative electron energy loss spectroscopy mapping of chromium species.

    PubMed

    Tan, Haiyan; Tian, He; Verbeeck, Jo; Monico, Letizia; Janssens, Koen; Van Tendeloo, Gustaaf

    2013-10-18

    Getting the picture: The investigation of 100 year old chrome yellow paint by transmission electron microscopy and spectroscopy has led to the identification of four types of core-shell particles. This nanoscale investigation has allowed a mechanism to be proposed for the darkening of some bright yellow colors in Van Gogh's paintings (e.g. in Falling leaves (Les Alyscamps), 1888). Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure.

    PubMed

    Chen, Jia-Kun

    2016-08-01

    An inclined plate for flow control was installed at the lower edge of the sash of an inclined air-curtain fume hood to reduce the effects of the wake around a worker standing in front of the fume hood. Flow inside the fume hood is controlled by the inclined air-curtain and deflection plates, thereby forming a quad-vortex flow structure. Controlling the face velocity of the fume hood resulted in convex, straight, concave, and attachment flow profiles in the inclined air-curtain. We used the flow visualization and conducted a tracer gas test with a mannequin to determine the performance of two sash geometries, namely, the half-cylinder and inclined plate designs. When the half-cylinder design was used, the tracer gas test registered a high leakage concentration at Vf ≦ 57.1 fpm or less. This concentration occurred at the top of the sash opening, which was close to the breathing zone of the mannequin placed in front of the fume hood. When the inclined plate design was used, the containment was good, with concentrations of 0.002-0.004 ppm, at Vf ≦ 63.0 fpm. Results indicate that an inclined plate effectively reduces the leakage concentration induced by recirculation flow structures that form in the wake of a worker standing in front of an inclined air-curtain fume hood.

  2. [Carriage of Staphylococcus aureus among food service workers].

    PubMed

    Alarcón-Lavín, María Paula; Oyarzo, Carolina; Escudero, Carlos; Cerda-Leal, Fabiola; Valenzuela, Francisco J

    2017-12-01

    Background Staphylococcus aureus produces 11 serotypes of endotoxins that may cause food poisoning. Aim To determine the prevalence of type A enterotoxigenic Staphylococcus aureus carriage among food service workers in Chillan, Chile. Material and Methods Pharyngeal swabs were obtained from 100 food service workers and were cultured in Agar plates. After identifying the presence of Staphylococcus aureus, DNA was extracted to identify type A toxin by conventional PCR. Results Thirty eight percent of samples were colonized with Staphylococcus aureus. Among these, 26% were toxin A producers. Conclusions Half of the sampled workers carried Staphylococcus aureus and a quarter of these produced type A enterotoxin.

  3. The influence of activating agents on the performance of rice husk-based carbon for sodium lauryl sulfate and chrome (Cr) metal adsorptions

    NASA Astrophysics Data System (ADS)

    Arneli; Safitri, Z. F.; Pangestika, A. W.; Fauziah, F.; Wahyuningrum, V. N.; Astuti, Y.

    2017-02-01

    This research aims to study the influence of activating agents to produce rice husk based-carbon with high adsorption capacity and efficiency for either hazardous organic molecules or heavy metals which are unfriendly for the environment. Firstly, rice husk was burned by pyrolysis at different temperatures to produce rice husk-based carbon. To improve its ability as an adsorbent, carbon was treated with activating agents, namely, H3PO4 and KOH at room and high temperature (420 °C). The performance of carbon was then tested by contacting it with surfactant (SLS). Finally, the surfactant-modified active carbon was applied for chrome metal removal. The result shows that activation of carbon using phosphate acid (H3PO4) was more effective than potassium hydroxide (KOH) conducted at high temperature to adsorb sodium lauryl sulfate (SLS) and chrome metal with the adsorption capacity 1.50 mgg-1 and 0.375 mgg-1, respectively.

  4. Thermal degradation of a black chrome solar selective absorber coating: short term

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lampert, C.M.

    1979-05-01

    Both the energy absorption properties and chemical microstructure of CHROM-ONYX were investigated using electron microscopy and X-ray diffraction techniques. Different temperatures for short annealing times were used to evaluate this coating's temperature resistance limitations along with possible degradation mechanisms for various stagnation situations. Samples were tested in both air and vacuum. As a result, each sample regardless of atmosphere was characteristically similar, with air acting to mildly accelerate optical degradation at higher temperatures. Below 300 to 400/sup 0/C black chrome exhibited a structural transformation precipitating Cr/sub 2/O/sub 3/. Above 500/sup 0/C this phase grew considerably, while chromium was depleted. Atmore » 600/sup 0/C and above, a new dominant phase developed corresponding to NiCr/sub 2/O/sub 4/, a cubic spinel. However, for all practical purposes black chrome optically degraded between 500 to 600/sup 0/C during short exposure times.« less

  5. Minimization of the environmental impact of chrome tanning: a new process with high chrome exhaustion.

    PubMed

    Morera, Josep M; Bacardit, Anna; Ollé, Lluís; Bartolí, Esther; Borràs, Maria D

    2007-11-01

    In all tanning technology operations wastes are generated. These reach the environment as residual waters, solid and liquid waste as well as atmospheric emissions and odours. This study tests an alternative method to the traditional tanning method at an industrial level. The new method is based on tanning without float and by significantly increasing the temperature at the end of the tanning process. The properties of the leathers obtained using the two methods have been compared and the results indicate that those leathers have similar physical, chemical, and organoleptic properties. However, the differences existing from the environmental point of view are significant. It is not necessary to use clean water for this tanning. Moreover, there is a 75% reduction of the residual float, a 91% reduction of the chrome discharged, and a 94% reduction of the chlorides discharged. A financial assessment was carried out to demonstrate that the newly proposed system is 32% more economic than the traditional one.

  6. Mechanisms of Zn(II) binded to collagen and its effect on the capacity of eco-friendly Zn-Cr combination tanning system.

    PubMed

    Cao, Shan; Liu, Bing; Cheng, Baozhen; Lu, Fuping; Wang, Yanping; Li, Yu

    2017-01-05

    The eco-friendly combination tanning process has been developed to reduce chromium in existing researches, which is based on zinc tanning agents. This can be considered as a less-chrome substitute for current tanning process. To gain deeper understanding of the binding mechanisms of zinc-collagen interaction, which are affected by tanning pH, experiments have been carried out. Analysis in this paper reveals how chemical bonds from the collagen's main function groups combine with zinc. XPS and NIR data was analyzed for further understanding of where the zinc binding sites lie on collagen fibers at different pH. The results indicate that high pH is helpful to amino-binding sites while low pH promotes carboxyl-binding sites on collagen fibers. Furthermore, from the effect of Zinc-chrome combination tanning, we can see that the new method reduces the chromium dosage in tanning process compared to the conventional chrome tanning method. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Comparative statistical analysis of chrome and vegetable tanning effluents and their effects on related soil.

    PubMed

    Tariq, Saadia R; Shah, Munir H; Shaheen, Nazia

    2009-09-30

    Two tanning units of Pakistan, namely, Kasur and Mian Channun were investigated with respect to the tanning processes (chrome and vegetable, respectively) and the effects of the tanning agents on the quality of soil in vicinity of tanneries were evaluated. The effluent and soil samples from 16 tanneries each of Kasur and Mian Channun were collected. The levels of selected metals (Na, K, Ca, Mg, Fe, Cr, Mn, Co, Cd, Ni, Pb and Zn) were determined by using flame atomic absorption spectrophotometer under optimum analytical conditions. The data thus obtained were subjected to univariate and multivariate statistical analyses. Most of the metals exhibited considerably higher concentrations in the effluents and soils of Kasur compared with those of Mian Channun. It was observed that the soil of Kasur was highly contaminated by Na, K, Ca and Mg emanating from various processes of leather manufacture. Furthermore, the levels of Cr were also present at much enhanced levels than its background concentration due to the adoption of chrome tanning. The levels of Cr determined in soil samples collected from the vicinity of Mian Channun tanneries were almost comparable to the background levels. The soil of this city was found to have contaminated only by the metals originating from pre-tanning processes. The apportionment of selected metals in the effluent and soil samples was determined by a multivariate cluster analysis, which revealed significant differences in chrome and vegetable tanning processes.

  8. Study of bacterial flora associated with mobile phones of healthcare workers and non-healthcare workers

    PubMed Central

    Morubagal, Raghavendra Rao; Shivappa, Sowmya Govindanahalli; Mahale, Rashmi Padmanabha; Neelambike, Sumana Mhadevaiah

    2017-01-01

    Background and Objectives: Despite improvements in modern diagnosis and therapies, hospital acquired infections remain a leading problem of global health systems. Healthcare workers mobile phones is a reservoir for potential pathogens. Despite the high possibility of being contaminated, mobile phones are rarely clean and are often touched during or after examination of patients and handling of specimens without proper hand washing. The main objective of the present study was to isolate, identify different types of bacteria and their antibiotic sensitivity from mobile phones of healthcare workers and non-health-care workers. Materials and Methods: Samples were collected aseptically by rolling over the exposed surfaces of the mobile phones inoculated on the agar plates and incubated aerobically. After incubation, plates were examined for growth. Bacteria were identified and antibiotic sensitivity was tested as per standard microbiological procedures. Results: In this study a total of 175 samples were examined, out of which 125 samples were from healthcare workers (HCWs), 50 samples were from non-healthcare workers (non-HCWs). Among the mobile phones of HCW’s from ICUs, Acinetobacter baumannii (36.84%) was the predominant organism isolated followed by methicillin resistant Staphylococcus aureus (MRSA) (21.05%). Predominant organism isolated from HCW’s in operation theater theater was MRSA (46.66%). Out of 50 worker’s non-HCWs mobile phones samples cultured, 23 (46.00%) samples yielded growth of six different types of bacteria. Conclusion: Our study reveals that there is definite colonization of bacteria on mobile phones of the HCWs. It is not only capable of transferring message but also disease-producing microbes. In order to reduce incidence of nosocomial infections, there should be implementation of hand washing practices and regulations around the use of mobile telephones in hospital settings. PMID:29225753

  9. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty.

    PubMed

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-06-15

    Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.

  10. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    PubMed Central

    2010-01-01

    Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. PMID:20550669

  11. Edge effects in phase-shifting masks for 0.25-µm lithography

    NASA Astrophysics Data System (ADS)

    Wong, Alfred K. K.; Neureuther, Andrew R.

    1993-03-01

    The impact on image quality of scattering from phase-shifter edges and of interactions between phase-shifter and chrome edges is assessed using rigorous electromagnetic simulation. Effects of edge taper in phase-shift masks, spacing between phase-shifter and chrome edges, small outrigger features with a trench phase-shifter, and of the repair of phase defects by etching to 360 degree(s) are considered. Near field distributions and diffraction efficiencies are examined and images are compared with more approximate results from the commonly used Hopkins' theory of imaging.

  12. [Spatial distribution of birth defects among children aged 0 to 5 years and its relationship with soil chemical elements in Chongqing].

    PubMed

    Dong, Yan; Zhong, Zhao-hui; Li, Hong; Li, Jie; Wang, Ying-xiong; Peng, Bin; Zhang, Mao-zhong; Huang, Qiao; Yan, Ju; Xu, Fei-long

    2013-10-01

    To explore the correlation between the incidence of birth defects and the contents of soil elements so as to provide a scientific basis for screening the related pathogenic factors that inducing birth defects for the development of related preventive and control strategies. MapInfo 7.0 software was used to draw the maps on spatial distribution regarding the incidence rates of birth defects and the contents of 11 chemical elements in soil in the 33 studied areas. Variables on the two maps were superposed for analyzing the spatial correlation. SAS 8.0 software was used to analyze single factor, multi-factors and principal components as well as to comprehensively evaluate the degrees of relevance. Different incidence rates of birth defects showed in the maps of spatial distribution presented certain degrees of negative correlation with anomalies of soil chemical elements, including copper, chrome, iodine, selenium, zinc while positively correlated with the levels of lead. Results from the principal component regression equation indicating that the contents of copper(0.002), arsenic(-0.07), cadmium(0.05), chrome (-0.001), zinc (0.001), iodine(-0.03), lead (0.08), fluorine(-0.002)might serve as important factors that related to the prevalence of birth defects. Through the study on spatial distribution, we noticed that the incidence rates of birth defects were related to the contents of copper, chrome, iodine, selenium, zinc, lead in soil while the contents of chrome, iodine and lead might lead to the occurrence of birth defects.

  13. Poultry feed based on protein hydrolysate derived from chrome-tanned leather solid waste: creating value from waste.

    PubMed

    Chaudhary, Rubina; Pati, Anupama

    2016-04-01

    Leather industry generates huge amount of chrome-containing leather solid waste which creates major environment problems to tanners worldwide. Chrome-tanned leather solid waste is primarily chromium complex of collagen protein. The presence of chromium limits its protein application in animal feed industry. The purified protein hydrolysate with zero chromium could be used in poultry feed. In this study, an attempt has been made to assess performance of poultry with purified protein hydrolysate as a feed derived from chrome-tanned leather waste as partial replacement of soyabean meal as a sole source of protein for growing broiler chickens. Growth study was conducted to evaluate the effect of feeding protein hydrolysate on performance and physiochemical characteristics of meat of broiler chickens. Two experimental diets containing various levels of protein hydrolysate (EI-20 % and EII-30 %) were evaluated. The comparative study was performed as control with soyabean meal. Daily feed intake, body weight gain and feed conversion ratio were measured from day 8 to day 35. At the end of the study, birds were randomly selected and slaughtered to evaluate for physiochemical characteristics of meat. Diet had significant effects on feed intake and body weight gain. Birds fed with 20 and 30 % protein hydrolysate consumed 9.5 and 17.5 % higher amount of feed and gained 6.5 and 16.6 % higher than soyabean meal-fed birds. The current study produced evidence that protein hydrolysate can replace up to 75 % of soyabean meal in broiler diets without affecting either growth performance or meat characteristics.

  14. Study on Movable gel Profiling/Flooding System Optimization at Boundary Temperature

    NASA Astrophysics Data System (ADS)

    Gao, Shanshan; Xie, Gang; Zhang, Tiantian; Wang, Zhiqiang; Jiang, Peijun; Wei, Junjie; Gu, Yi; Lei, Xiaoyang; Guo, Suzhen; Lei, Shi

    2017-12-01

    65-75°C is the boundary temperature of phenol-formaldehyde resin and organic chrome crosslink with HPAM to generate movable gel. Generally speaking, when the reservoir temperature is below 65-75°C, the crosslinking agent is Organic chrome. Phenol-formaldehyde resin is used when the temperature is above 65-75°C. In this paper the gelation properties of phenol-formaldehyde resin and organic chrome were compared at 70°C. The experiment results showed that the crosslinking time of phenol-formaldehyde resin gel was longer and more conducive to field injection. In addition the phenol-formaldehyde resin gel had greater viscosity, adhesion and shearing resistance compared with the organic chrome gel. So the phenol-formaldehyde resin was chosen for further optimization. The crosslinking time was shortened and the gel viscosity increased with the increase of the polymer concentration. As the polymer crosslinker proportion increased The crosslinking time was shortened and the gel viscosity increased first and then decreased. Reinforcer NC and stabilizer WG were added to improve the temperature and salt tolerance of the gel. The gel formula suitable for the boundary temperature was obtained. The optimum polymer concentration is 1200mg/L, the polymer crosslinker proportion is 1:1.1, the best reinforcer concentration is 400mg/L and the concentration of the stabilizer is 150mg/L. The crosslinking time is 31h, the gel viscosity is above 2100mPa·s. The gel did not shrink and no water separation was observed at 70°C for 150 days. The viscosity retention rate was more than 70%.

  15. Occupational exposure to Cr(VI): comparison between chromium levels in lymphocytes, erythrocytes, and urine.

    PubMed

    Lukanova, A; Toniolo, P; Zhitkovich, A; Nikolova, V; Panev, T; Popov, T; Taioli, E; Costa, M

    1996-01-01

    The relationships between chromium (Cr) levels in lymphocytes, erythrocytes, urine, and ambient air were compared among 14 chrome-platers from a metallurgic plant in Bulgaria and two groups of local controls, one from the same heavily polluted industrial town as the chrome-platers (n = 11) and one from a seaside resort town 100 km away (n = 6). Among the chrome-platers, the Cr concentration in peripheral lymphocytes was positively correlated with total Cr and Cr(VI) levels in ambient air and with Cr excretion in urine. As compared to the controls, the chrome-platers had mean Cr levels in lymphocytes twice as high, in erythrocytes ninefold higher, and in urine fourfold to eightfold higher. Although Cr levels in urine and lymphocytes were similar between the two control groups, levels in erythrocytes were 3 times higher among subjects from the industrial area than among those from the seaside town. The study suggests that lymphocyte Cr could be a good indicator of the Cr body burden caused by high exposures to Cr(VI), such as in electroplating operations. In these conditions, erythrocyte Cr may be less useful, possibly owing to increased toxicity due to the high affinity of erythrocytes for Cr. However, when exposure is lower, such as in most environmental situations, erythrocyte Cr should provide a better and more sensitive index than lymphocyte Cr. By contrast, urinary Cr, which provides information on total Cr exposure, including Cr(III) from dietary and environmental sources, does not seem to be of value for studying occupational exposure to Cr(VI).

  16. High Temperature Brush Seal Tuft Testing of Selected Nickel-Chrome and Cobalt-Chrome Superalloys

    NASA Technical Reports Server (NTRS)

    Fellenstein, James A.; DellaCorte, Christopher; Moore, Kenneth D.; Boyes, Esther

    1997-01-01

    The tribology of brush seals is of considerable interest to turbine engine designers because bristle wear continues to limit long term seal performance and life. To provide better materials characterization and foster the development of improved seals, NASA Lewis has developed a brush seal tuft tester. In this test, a 'paintbrush' sample tuft is loaded under constant contact pressure against the outside diameter of a rotating journal. With this configuration, load and friction are directly measured and accurate wear measurements are possible. Previously reported research using this facility showed excellent data repeatability and wear morphology similar to published seal data and dynamic rig tests. This paper is an update of the ongoing research into the tribology of brush seals. The effects of wire materials processing on seal wear and the tribological results for three journal coatings are discussed. Included in the materials processing were two nickel-chrome superalloys each processed to two different yield strengths. The results suggest that seal wear is dependent more on material composition than processing conditions.

  17. Halloysite nanotubule clay for efficient water purification.

    PubMed

    Zhao, Yafei; Abdullayev, Elshad; Vasiliev, Alexandre; Lvov, Yuri

    2013-09-15

    Halloysite clay has chemical structure similar to kaolinite but it is rolled in tubes with diameter of 50 nm and length of ca. 1000 nm. Halloysite exhibits higher adsorption capacity for both cationic and anionic dyes because it has negative SiO2 outermost and positive Al2O3 inner lumen surface; therefore, these clay nanotubes have efficient bivalent adsorbancy. An adsorption study using cationic Rhodamine 6G and anionic Chrome azurol S has shown approximately two times better dye removal for halloysite as compared to kaolin. Halloysite filters have been effectively regenerated up to 50 times by burning the adsorbed dyes. Overall removal efficiency of anionic Chrome azurol S exceeded 99.9% for 5th regeneration cycle of halloysite. Chrome azurol S adsorption capacity decreases with the increase of ionic strength, temperature and pH. For cationic Rhodamine 6G, higher ionic strength, temperature and initial solution concentration were favorable to enhanced adsorption with optimal pH 8. The equilibrium adsorption data were described by Langmuir and Freundlich isotherms. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. [Screening and identification of an endophytic bacterium with 1-aminocyclopropane-1-carboxylate deaminase activity from Panax ginseng and its effect on host growth].

    PubMed

    Tian, Lei; Jiang, Yun; Chen, Changqing; Zhang, Guanjun; Li, Tong; Tong, Bin; Xu, Peng

    2014-07-04

    This study aimed to screen endophytic bacteria with 1-aminocyclopropane-1-carboxylate deaminase activity from Panax ginseng and test the capability of growth promotion to its host. In total 120 endophytic bacterial strains isolated from Panax ginseng were screened for 1-aminocyclopropane-1-carboxylate deaminase activity using the qualitative and quantitative methods. The obtained strain was also tested for its ability of nitrogen fixation using the Ashby agar plates and the gene of nifH, for its ability of phosphate solubilization using the Pikovaskaia's plates and quantitative analysis of Mo-Sb-Ascrobiology acid colorimetry, for its ability of producing siderophores using the method of Chrome azurol S detecting, and its effect on promoting growth of Panax ginseng by laboratory and field experiments. The bacterial strain with ACC deaminase was identified based on morphology, physiological and biochemical traits, and 16S rRNA sequence analysis. The bacterial stain JJ8-3 with the ability of producing ACC deaminase activity was obtained through screening, which its ACC deaminase activity was alpha-ketobutyric acid 6.7 micromol/(mg x h). Strain JJ8-3 had other traits of phosphate solubilizing, nitrogen fixation, producing siderophores, and the ability of promoting growth of Panax ginseng. Strain JJ8-3 was identified as Pseudomonas fluorescens. Strain JJ8-3 of endophytic bacterium with ACC deaminase activity from Panax ginseng was obtained and would lay the foundation for its further study and application on plant growth promotion.

  19. ET Toxic Metals Replacement Review SEA Spring Face to Face

    NASA Technical Reports Server (NTRS)

    Pratz, Earl

    2007-01-01

    The information contained in the presentation covers development work carried out under SDS projects. The intent of the effort is to find chrome(VI) free alternates to our current chromated processing solutions. The information presented reports progress in work aimed to replace our alkaline cleaner (Turco 4215), conversion coat (Iridite 14-2) and chrome (VI) compounds used in LOx tank hydrostatic proof test solution. To date we have found candidates for use in the proof test solution and alkaline cleaner. These candidates are in the final stages of testing. Lab data is reported in the presentation.

  20. Role of the offshore Pedro Banks left-lateral strike-slip fault zone in the plate tectonic evolution of the northern Caribbean

    NASA Astrophysics Data System (ADS)

    Ott, B.; Mann, P.; Saunders, M.

    2013-12-01

    Previous workers, mainly mapping onland active faults on Caribbean islands, defined the northern Caribbean plate boundary zone as a 200-km-wide bounded by two active and parallel strike-slip faults: the Oriente fault along the northern edge of the Cayman trough with a GPS rate of 14 mm/yr, and and the Enriquillo-Plaintain Garden fault zone (EPGFZ) with a rate of 5-7 mm/yr. In this study we use 5,000 km of industry and academic data from the Nicaraguan Rise south and southwest of the EPGFZ in the maritime areas of Jamaica, Honduras, and Colombia to define an offshore, 700-km-long, active, left-lateral strike-slip fault in what has previously been considered the stable interior of the Caribbean plate as determined from plate-wide GPS studies. The fault was named by previous workers as the Pedro Banks fault zone because a 100-km-long segment of the fault forms an escarpment along the Pedro carbonate bank of the Nicaraguan Rise. Two fault segments of the PBFZ are defined: the 400-km-long eastern segment that exhibits large negative flower structures 10-50 km in width, with faults segments rupturing the sea floor as defined by high resolution 2D seismic data, and a 300-km-long western segment that is defined by a narrow zone of anomalous seismicity first observed by previous workers. The western end of the PBFZ terminates on a Quaternary rift structure, the San Andres rift, associated with Plio-Pleistocene volcanism and thickening trends indicating initial rifting in the Late Miocene. The southern end of the San Andreas rift terminates on the western Hess fault which also exhibits active strands consistent with left-lateral, strike-slip faults. The total length of the PBFZ-San Andres rift-Southern Hess escarpment fault is 1,200 km and traverses the entire western end of the Caribbean plate. Our interpretation is similar to previous models that have proposed the "stable" western Caribbean plate is broken by this fault whose rate of displacement is less than the threshold recognizable from the current GPS network (~3 mm/yr). The Late Miocene age of the fault indicates it may have activated during the Late Miocene to recent Hispaniola-Bahamas oblique collision event.

  1. Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

    NASA Technical Reports Server (NTRS)

    Simon, F. F.

    1975-01-01

    The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

  2. Covalently bonded ionic liquid onto cellulose for fast adsorption and efficient separation of Cr(VI): Batch, column and mechanism investigation.

    PubMed

    Dong, Zhen; Zhao, Long

    2018-06-01

    Combining the advantages of both cellulose and ionic liquid, ionic liquid functionalized cellulose (ILFC) as adsorbent was prepared through radiation grafting glycidyl methacrylate onto cellulose microsphere following by reaction with ionic liquid 1-aminopropyl-3-methyl imidazolium nitrate. Its adsorption properties towards Cr(VI) were investigated in batch and column experiments. In batch experiments, the adsorption kinetics was well fitted with pseudo-second-order mode with equilibrium time of 2 h and the adsorption capacity reached 181.8 mg/g at pH 2 calculated from Langmuir model. In fixed column, both Yoon-Nelson and Thomas models gave satisfactory fit to experimental data and breakthrough curves, and equilibrium adsorption capacity calculated by Thomas model was 161.0 mg/g. Moreover, ILFC exhibited high selectivity towards Cr(VI) even in synthetic chrome-plating wastewater. Besides, adsorption/desorption test revealed ILFC can be regenerated and reused several times without obvious decrease in adsorbed amount. The adsorption process was demonstrated to anion exchange-reduction mechanism via XPS analysis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Adsorption isotherm studies of chromium (VI) from aqueous solutions using sol-gel hydrotalcite-like compounds.

    PubMed

    Ramos-Ramírez, Esthela; Ortega, Norma L Gutiérrez; Soto, Cesar A Contreras; Gutiérrez, Maria T Olguín

    2009-12-30

    In under-developed countries, industries such as paint and pigment manufacturing, leather tanning, chrome plating and textile processing, usually discharge effluents containing Cr(VI) and Cr(III) into municipal sanitary sewers. It has been reported that Cr(VI) acts as a powerful epithelial irritant and as a human carcinogen. In the present work, hydrotalcite-like compounds with a Mg/Al ratio=2 were synthesized by the sol-gel method. The hydrotalcite-like compounds and their corresponding thermally treated products were characterized by powder X-ray diffraction, infrared spectroscopy and N(2) adsorption. The hydrotalcite-like compounds and the heated solids were used as adsorbents for Cr(VI) in aqueous solutions. Adsorption isotherm studies of Cr(VI) from aqueous solution are described. The adsorbent capacity was determined using the Langmuir, Freundlich and Dubinin-Radushkevich adsorption isotherm models. The Cr(VI) adsorption isotherm data fit best to the Langmuir isotherm model. The maximum Cr(VI) uptake by hydrotalcite and the heated solids was determined using the Langmuir equation and was found to range between 26 and 29 mg Cr(VI)/g adsorbent.

  4. Chitosan supramolecularly cross linked with trimesic acid - Facile synthesis, characterization and evaluation of adsorption potential for chromium(VI).

    PubMed

    Bhatt, Ronak; Sreedhar, B; Padmaja, P

    2017-11-01

    A facile synthesis of Chitosan Supramolecularly cross-linked with Trimesic Acid (CTMA) is reported in this work. The adsorption potential of CTMA for removal of hexavalent chromium was evaluated and the influence of pH, temperature, contact time and adsorbent dose on the adsorption process was investigated. The experimental results showed that CTMA could efficiently adsorb Cr 6+ and partially reduce it to the less toxic Cr 3+ state. The maximum adsorption capacity of CTMA for Cr 6+ was found to be 129.53mg/g at pH 2.0. CTMA and chromium loaded CTMA were characterised by FT-IR, Raman, TGA-DSC, SEM-EDX, XRD, ESR and XPS spectroscopic techniques. Chitosan was observed to be cross- linked with TMA via ionic, hydrogen bonding and pi-pi supramolecular interactions while adsorption of chromium onto CTMA was by electrostatic forces and hydrogen bonding. From the observed results it was evident that CTMA was successfully applied for simultaneous removal of chromium, lead and iron from chrome plating effluent. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Carcinogenicity and mutagenicity of chromium.

    PubMed

    Léonard, A; Lauwerys, R R

    1980-11-01

    Occupational exposure represents the main source of human contamination by chromium. For non-occupationally exposed people the major environmental exposure to chromium occurs as a consequence of its presence in food. Chromium must be considered as an essential element. Its deficiency impairs glucose metabolism. Trivalent chromium salts are poorly absorbed through the gastro-intestinal and respiratory tracts because they do not cross membranes easily. Hexavalent chromium can be absorbed by the oral and pulmonary routes and probably also through the skin. After its absorption, hexavalent chromium is rapidly reduced to the trivalent form which is probably the only form to be found in biological material. Epidemiological studies have shown that some chromium salts (mainly the slightly soluble hexavalent salts) are carcinogens. Lung cancers have, indeed, often been reported among workers in chromate-producing industry and, to a lesser extent, in workers from the chrome-pigment industry. The first attempts to produce cancers in experimental animals by inhalation or parenteral introduction gave negative or equivocal results but, from 1960, positive results have been obtained with various chromium compounds. As for the carcinogenic activity, the mutagenicity of chromium has mainly been found with hexavalent salts. In the majority of assay systems used, trivalent chromium appears inactive. It can be considered as evident, however, that the ultimate mutagen which binds to the genetic material is the trivalent form produced intracellularly from hexavalent chromium, the apparent lack of activity of the trivalent form being due to its poor cellular uptake.

  6. Chromium-induced kidney disease.

    PubMed

    Wedeen, R P; Qian, L F

    1991-05-01

    Kidney disease is often cited as one of the adverse effects of chromium, yet chronic renal disease due to occupational or environmental exposure to chromium has not yet been reported. Occasional cases of acute tubular necrosis (ATN) following massive absorption of chromate have been described. Chromate-induced ATN has been extensively studied in experimental animals following parenteral administration of large doses of potassium chromate (hexavalent) (15 mg/kg body weight). The chromate is selectively accumulated in the convoluted proximal tubule where necrosis occurs. An adverse long-term effect of low-dose chromium exposure on the kidneys is suggested by reports of low molecular weight (LMW) proteinuria in chromium workers. Excessive urinary excretion of beta 2-microglobulin, a specific proximal tubule brush border protein, and retinol-binding protein has been reported among chrome platers and welders. However, LMW proteinuria occurs after a variety of physiologic stresses, is usually reversible, and cannot by itself be considered evidence of chronic renal disease. Chromate-induced ATN and LMW proteinuria in chromium workers, nevertheless, raise the possibility that low-level, long-term exposure may produce persistent renal injury. The absence of evidence of chromate-induced exposure may produce persistent renal injury. The absence of evidence of chromate-induced chronic renal disease cannot be interpreted as evidence of the absence of such injury. Rather, it must be recognized that no prospective cohort or case-control study of the delayed renal effects of low-level, long-term exposure to chromium has been published.

  7. Seroprevalence and risk factors of brucellosis in abattoir workers at Debre Zeit and Modjo export abattoir, Central Ethiopia.

    PubMed

    Tsegay, Amanuel; Tuli, Getachew; Kassa, Tesfu; Kebede, Nigatu

    2017-01-26

    Brucellosis is one of the major zoonoses globally with great veterinary and public health importance, particularly in developing countries where people are having frequent contact with livestock and animal products. This cross sectional study was carried out from November 2013 to May 2014 to determine the seroprevalence and assess the potential risk factors of brucellosis in abattoir workers of five export abattoirs at Debre Ziet and Modjo, Central Ethiopia. Serology and structured questionnaire were the methods used. In this study, 156 abattoir workers participated in the questionnaire survey and among them, 149 agreed for blood sample collection. Rose Bengal Plate Test and Complement Fixation Test were conducted using sera samples at serology laboratory of the National Animal Health Diagnostic and Investigation Center. Data collection sheets were used to gather information on possible risk factors believed to influence the spread of Brucella infection in abattoir workers such as sex, age, marital status, duration on job, types of work, educational level, etc. and further information obtained include knowledge of brucellosis and other zoonotic diseases infection, symptoms of the disease, milk and meat consumption habits and work related risk factors. Chi-square and Fisher's exact tests were used for data analysis. The overall seroprevalence of brucellosis in abattoir workers was found to be 4.7 and 1.3% using Rose Bengal plate test and Compliment fixation test, respectively. Based on the questionnaire survey, 66 (44.2%) and 85 (53.21%) of abattoir workers were aware of brucellosis and other zoonotic diseases, and 29 (18.6%) and 21 (13.5%) were using gloves and cover their mouth while slaughtering, respectively. Brucellosis in abattoir workers could be prevented by using protective closing and measures. Concerned body should educate occupationally exposed groups and the general public regarding e prevention and control of brucellosis and other zoonotic diseases.

  8. Chrome-tanned leather shavings as a filler of butadiene-acrylonitrile rubber.

    PubMed

    Przepiórkowska, A; Chrońska, K; Zaborski, M

    2007-03-06

    The noxious wastes from the tanning industry such as chrome-tanned leather shavings were used as the only filler of rubber mixes containing carboxylated butadiene-acrylonitrile rubber (XNBR) or butadiene-acrylonitrile rubber (NBR), and a dispersing agent Limanol PEV (Schill & Seilacher). The best form addition of leather powder to the rubber mixes is mixed the waste protein with zinc oxide. The leather powder added to the rubber mixes improves the mechanical properties: tensile strength (T(s)), elongation at break (epsilon(b)) and increase the cross-linking density of carboxylated XNBR and NBR rubber mixes. Satisfactory results of these studies are presented in this work.

  9. No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature.

    PubMed

    Thienpont, Emmanuel; Berger, Yorick

    2013-03-01

    Hypersensitivity to metallic implants remains relatively unpredictable and poorly understood. Although 20-25 % of total joint arthroplasty patients develop metal sensitivity, only a few highly susceptible persons (<1 %) exhibit symptoms. We present a case report of a fifty-two-year-old woman with a preoperatively documented metal allergy who underwent bilateral total knee arthroplasty using a titanium-niobium-coated implant on one side and a chrome-cobalt implant on the other side because of a logistics problem. At 2-year follow-up, no clinical symptoms of allergy or loosening of the implant were observed. Level of evidence IV.

  10. NASA TEERM Hexavalent Chrome Alternatives Projects

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.; Rothgeb, Matthew

    2011-01-01

    The overall objective of the Hex Chrome Free Coatings for Electronics project is to evaluate and test pretreatment coating systems not containing hexavalent chrome in avionics and electronics housing applications. This objective will be accomplished by testing strong performing coating systems from prior NASA and DoD testing or new coating systems as determined by the stakeholders. The technical stakeholders have agreed that this protocol will focus specifically on Class 3 coatings. Original Equipment Manufacturers (OEMs), depots, and support contractors have to be prepared to deal with an electronics supply chain that increasingly provides parts with lead-free finishes, some labeled no differently and intermingled with their SnPb counterparts. Allowance of lead-free components presents one of the greatest risks to the reliability of military and aerospace electronics. The introduction of components with lead-free terminations, termination finishes, or circuit boards presents a host of concerns to customers, suppliers, and maintainers of aerospace and military electronic systems such as: 1. Electrical shorting due to tin whiskers 2. Incompatibility of lead-free processes and parameters (including higher melting points of lead-free alloys) with other materials in the system 3. Unknown material properties and incompatibilities that could reduce solder joint reliability

  11. Kinetic model of the thermal pyrolysis of chrome tanned leather treated with NaOH under different conditions using thermogravimetric analysis.

    PubMed

    Bañón, E; Marcilla, A; García, A N; Martínez, P; León, M

    2016-02-01

    The thermal decomposition of chrome tanned leather before and after a soaking treatment with NaOH was studied using thermogravimetric analysis (TGA). The effect of the solution concentration (0.2M and 0.5M) and the soaking time (5min and 15min) was evaluated. TGA experiments at four heating rates (5, 10, 15 and 20°Cmin(-1)) were run in a nitrogen atmosphere for every treatment condition. A kinetic model was developed considering the effect of the three variables studied, i.e.: the NaOH solution concentration, the soaking time and the heating rate. The proposed model for chrome tanned leather pyrolysis involves a set of four reactions, i.e.: three independent nth order reactions, yielding the corresponding products and one of them undergoing a successive cero order reaction. The model was successfully applied simultaneously to all the experimental data obtained. The evaluation of the kinetic parameters obtained (activation energy, pre-exponential factor and reaction order) allowed a better understanding of the effect of the alkali treatment on these wastes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. A novel automatic full-scale inspecting system for banknote printing plates

    NASA Astrophysics Data System (ADS)

    Zhang, Jian; Feng, Li; Lu, Jibing; Qin, Qingwang; Liu, Liquan; Liu, Huina

    2018-01-01

    Quality assurance of banknote printing plates is an important issue for the corporation which produces them. Every plate must be checked carefully and entirely before it's sent to the banknote printing factory. Previously the work is done by specific workers, usually with the help of powder and magnifiers, and often lasts for 3 to 4 hours for a 5*7 plate with the size of about 650*500 square millimeters. Now we have developed an automatic inspecting system to replace human work. The system mainly includes a stable platform, an electrical subsystem and an inspecting subsystem. A microscope held by the crossbeam can move around in the x-y-z space over the platform. A digital camera combined with the microscope captures gray digital images of the plate. The size of each digital image is 2672*4008, and each pixel corresponds to about 2.9*2.9 square microns area of the plate. The plate is inspected by each unit, and corresponding images are captured at the same relative position. Thousands of images are captured for one plate (for example, 4200 (120*5*7) for a 5*7 plate). The inspecting model images are generated from images of qualified plates, and then used to inspect indeterminate plates. The system costs about 64 minutes to inspect a plate, and identifies obvious defects.

  13. 77 FR 59013 - State Journal Register, Camera and Plate Department, Springfield, IL; Notice of Affirmative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-25

    ... engaged in activities related to the production of a daily newspaper. The subject worker group performs... affected by the shift of ``advertising ad work'' to a foreign country. The Department will conduct further...

  14. Influence of polyurethane resin dies on the fit and adaptation of full veneer crowns.

    PubMed

    Lillywhite, Graeme R R; Vohra, Fahim

    2015-01-01

    Polyurethane resin is a possible alternative to type IV dental stone for fabrication of indirect restorations however its dimensional accuracy is questionable. The aim was to investigate the dimensional accuracy of silica filled polyurethane resin die material by evaluating the marginal fit and adaptation of indirect gold castings. Experimental, in vitro study. Totally 40 copper plated replicas of a nickel chrome master die analogous to a veneer gold crown preparation were made and impressions recorded using polyvinylsiloxane material. Twenty impressions were poured in type IV dental stone (control group (Vel-mix, Kerr, UK) and the remaining (n = 20) in silica filled polyurethane die material (test group) (Alpha Die MF, CA, USA). Gold castings were fabricated for each die using standardized techniques. The castings were seated on their respective copper plated dies, embedded in resin and sectioned. The specimens were analyzed by measuring marginal opening and the area beneath the casting at a ×63 magnification and using image analysis software. Data were analyzed using a Student's t-test. No significant difference was observed between the experimental groups (P > 0.05). The mean marginal opening for type IV, dental stone and polyurethane resin, was 57 ± 22.6 μm and 63.47 ± 27.1 μm, respectively. Stone displayed a smaller area beneath the casting (31581 ± 16297 μm 2 ) as compared to polyurethane resin (35003 ± 23039 μm 2 ). The fit and adaptation of indirect gold castings made on polyurethane and type IV dental stone dies were comparable.

  15. Molecular and cellular mechanisms of hexavalent chromium-induced lung cancer: an updated perspective.

    PubMed

    Urbano, A M; Ferreira, L M R; Alpoim, M C

    2012-03-01

    For over a century, chromium (Cr) has found widespread industrial and commercial use, namely as a pigment, in the production of stainless steel and in chrome plating. The adverse health effects to the skin and respiratory tract of prolonged exposure to Cr have been known or suspected for a long time, but it was much more recently that the toxicity of this element was unequivocally attributed to its hexavalent state. Based on the combined results of extensive epidemiological studies, animal carcinogenicity studies and several types of other relevant data, authoritative regulatory agencies have found sufficient evidence to classify hexavalent chromium [Cr(VI)] compounds as encountered in the chromate production, chromate pigment production and chromium plating industries as carcinogenic to humans. Crucial for the development of novel strategies to prevent, detect and/or treat Cr(VI)-induced cancers is a detailed knowledge of the molecular and cellular mechanisms underlying these pathologies. Unfortunately, in spite of a considerable research effort, crucial facets of these mechanisms remain essentially unknown. This review is intended to provide a concise, integrated and critical perspective of the current state of knowledge concerning multiple aspects of Cr(VI) carcinogenesis. It will present recent theories of Cr(VI)-induced carcinogenesis and will include aspects not traditionally covered in other reviews, such as the possible involvement of the energy metabolism in this process. A brief discussion on the models that have been used in the studies of Cr(VI)-induced carcinogenicity will also be included, due to the impact of this parameter on the relevance of the results obtained.

  16. [Evaluation of long-term occupational exposure to dust and its effect on health during production of ceramic tiles].

    PubMed

    Gielec, L; Izycki, J; Woźniak, H

    1992-01-01

    A medical examination has been carried out of 500 workers (290 men and 210 women) of a ceramic plates plant. Also, the measurements of dust concentrations were made at some standard work places . In the materials used for manufacturing the plates crystalline phases and the content of free crystalline silica were determined using the X-ray diffraction method. In the animal experiments the fibrogenic activity of all materials used in the plant was examined and compared to the fibrogenic activity of standard quartz. As a result of the medical examination 64 cases of pneumoconiosis were diagnosed (13% of the subjects). The incidence rate of pneumoconiosis was similar for men and women. The radiological changes characteristic of pneumoconiosis took approximately 24 years of the workers tenure to develop. Type q changes were most frequent (69%), types p and r were observed in 14% of workers (mostly women). In 31% of workers tuberous changes of size B were observed. In 43.8% of the subjects restrictive disorders of ventilation were found. In 30% of workers chronic bronchitis was diagnosed. Dust concentrations at 11 work places were measured using the individual dosimetry method. Total dust concentrations ranged from 0.6 mg/m3 at the electricians posts to 60.1 mg/m3 at the workposts where the furnace truck restorers worked. Dust concentrations exceeded the MACs at 7 workposts. The respirable fraction concentrations ranged from 0.1 mg/m3 to 8.4 mg/m3. During the replacement of asbestos ropes and asbestos board used for insulating the furnace trucks mineral fibres (0.1-0.5 fibre/cm3) were found in the air. The following crystalline phases were determined in the materials: kaolinite, illite, quartz, orthoclase and microline.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Final Test Report: Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE)

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2016-01-01

    The test results for Salt Spray Resistance, Static Heat and Humidity and Marine Environment can be found in Sections 3.1.3.3, 3.1.4.3 and 3.1.5.3 respectively. In summary, both the Metalast TCP and SurTec 650 Type 2 conversion coatings perform very similar to the incumbent Type 1 conversion coating against both 6061 and 5052 aluminum under all three test conditions. Significant prior work was performed to select the aluminum and conversion coating included within this test cycle; Reference - NASA GSDO Program Hexavalent Chrome Alternatives Final Pretreatments Test Report Task Order: NNH12AA45D September 01, 2013. As illustrated in the data, the 6061 aluminum panels SLIGHTLY out-performed the 5052 aluminum panels. Individual shielding effectiveness graphs for each panel are included within Appendix C and D. One other notable effect found during review of the data is that the Test Panels exposed to B117 Salt Fog reduced in shielding effectiveness significantly more than the Marine Environment Test Panels. The shielding effectiveness of the Marine Test Panels was approximately 20dB higher than the Test Panels that underwent B117 Salt Fog Exposure. The intent of this evaluation was not to maximize shielding effectiveness values. The same Parker Chomerics Cho-Seal 6503 gasket material was used for all panels with aluminum and conversion coating variants. A typical EMI gasket design for corrosive environments would be done quite differently. The intent was to execute a test that would provide the best possible evaluation of different aluminum materials and conversion coatings in corrosive environments. The test program achieved this intent. The fact that the two aluminums and two Type II conversion coatings performed similar to the incumbent Type 1 conversion coating is a positive outcome. It was desired to have an outcome that further differentiation the performance of two aluminum types and two conversion coating types but this could not be extracted by the test results. Further analysis of the test plates may be done by X-Ray Photoelectron Spectroscopy (XPS) or Electrochemical Impedance Spectroscopy (EIS). Feasibility of this is under review.

  18. Radiation induced graft copolymerization of methyl methacrylate onto chrome-tanned pig skins

    NASA Astrophysics Data System (ADS)

    Pietrucha, K.; Pȩkala, W.; Kroh, J.

    Graft copolymerization of methyl methacrylate (MMA) onto chrome-tanned pig skins was carried out by the irradiation with 60Co ?-rays. The grafted polymethyl methacrylate (PMMA) chains were isolated by acid hydrolysis of the collagen backbone in order to characterize the graft copolymers. Proof of grafting was obtained through the detection of amino acid endgroups in the isolated grafts by reaction with ninhydrin. The grafting yield of MMA in aqueous emulsion was found to be higher than that for pure MMA and MMA in acetone. The degree of grafting increases with increasing monomer concentration in emulsion and reaches maximum at radiation dose ca 15 kGy. The yield of grafting is very high - ca 90% of monomer converts into copolymer and only 10% is converted into homopolymer. The present paper reports the physical properties of chrome-tanned pig skins after graft polymerization with MMA in emulsion. Modified leathers are more resistant against water absorption and abrasion in comparison with unmodified ones. They have more uniform structure over the whole surface, greater thickness and stiffness. The results reported seem to indicate that MMA may be used in the production of shoe upper and sole leathers. The mechanism of some of the processes occuring during radiation grafting of MMA in water emulsion on tanned leathers has been also suggested and discussed.

  19. A numerical investigation into the influence of the properties of cobalt chrome cellular structures on the load transfer to the periprosthetic femur following total hip arthroplasty.

    PubMed

    Hazlehurst, Kevin Brian; Wang, Chang Jiang; Stanford, Mark

    2014-04-01

    Stress shielding of the periprosthetic femur following total hip arthroplasty is a problem that can promote the premature loosening of femoral stems. In order to reduce the need for revision surgery it is thought that more flexible implant designs need to be considered. In this work, the mechanical properties of laser melted square pore cobalt chrome molybdenum cellular structures have been incorporated into the design of a traditional monoblock femoral stem. The influence of incorporating the properties of cellular structures on the load transfer to the periprosthetic femur was investigated using a three dimensional finite element model. Eleven different stiffness configurations were investigated by using fully porous and functionally graded approaches. This investigation confirms that the periprosthetic stress values depend on the stiffness configuration of the stem. The numerical results showed that stress shielding is reduced in the periprosthetic Gruen zones when the mechanical properties of cobalt chrome molybdenum cellular structures are used. This work identifies that monoblock femoral stems manufactured using a laser melting process, which are designed for reduced stiffness, have the potential to contribute towards reducing stress shielding. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Evaluation of TF11 attenuated-PSM mask blanks with DUV laser patterning

    NASA Astrophysics Data System (ADS)

    Xing, Kezhao; Björnberg, Charles; Karlsson, Henrik; Paulsson, Adisa; Beiming, Peter; Vedenpää, Jukka; Walford, Jonathan

    2008-05-01

    Tightening requirements on resolution, CD uniformity and positional accuracy push the development of improved photomask blanks. One such blank for 45nm node attenuated phase shift masks (att-PSM) provides a thinner chrome film, TF11, with a higher etch rate compared to previous generation NTAR5 att-PSM blanks from the same supplier. FEP-171, a positive chemically amplified resist, is commonly used in mask manufacturing for both e-beam and DUV laser pattern generators. TF11 chrome allows the FEP-171 resist thickness to be decreased at least down to 2000 Å while maintaining sufficient etch resistance, thereby improving photomask CD performance. The lower stress level in TF11 chrome films also reduces the image placement error induced by the material. In this study, TF11 chrome and FEP-171 resist are evaluated with exposures on a 248 nm DUV laser pattern generator, the Sigma7500. Patterning is first characterized for resist thicknesses of 2000 Å to 2600 Å in steps of 100 Å, assessing the minimum feature resolution, CD linearity, isolated-dense CD bias and dose sensitivity. Swing curve analysis shows a minimum near 2200 Å and a maximum near 2500 Å, corresponding closely to the reflectivity measurements provided by the blank supplier. The best overall patterning performance is obtained when operating near the swing maximum. The patterning performance is then studied in more detail with a resist thickness of 2550 Å that corresponds to the reflectivity maximum. This is compared to the results with 2000 Å resist, a standard thickness for e-beam exposures on TF11. The lithographic performance on NTAR5 att-PSM blanks with 3200 Å resist is also included for reference. This evaluation indicates that TF11 blanks with 2550 Å resist provide the best overall mask patterning performance obtained with the Sigma7500, showing a global CD uniformity below 4 nm (3s) and minimum feature resolution below 100 nm.

  1. In-situ phosphatizing coatings for aerospace, OEM and coil coating applications

    NASA Astrophysics Data System (ADS)

    Neuder, Heather Aurelia

    The current metal coating process is a multi-step process. The surface is cleaned, primered, dried and then painted. The process is labor intensive and time consuming. The wash primer is a conversion coating, which prepares metal surface for better paint adhesion. The wash primers currently used often contain hexavalent chromium (Cr6+), which seals the pores in the conversion coating. The presence of hexavalent chromium, a known carcinogen, and volatile organic compounds (VOCs) make waste disposal expensive and pose dangers to workers. The novel technique of in-situ phosphatizing coating (ISPC) is a single-step, chrome-free alternative to the present coating practice. Formulation of an ISPC involves predispersal of an in-situ phosphatizing reagent (ISPR) into the paint system to form a stable formulation. The ISPR reacts with the metal surface and bonds with the paint film simultaneously, which eliminates the need for a conversion coating. In acid catalyzed paint systems, such as polyester-melamine paints, the ISPR also catalyzes cross-linking reactions between the melamine and the polyester polyols. ISPCs are formulated using commercially available coating systems including: polyester-melamine, two-component epoxy, polyurethane and high-hydroxy content polyester-melamine coil coating. The ISPCs are applied to metal substrates and their performances are evaluated using electrochemical, thermal and standard American Society for Testing and Materials (ASTM) testing methods. In addition, ISPCs were designed and formulated based on: (1) phosphate chemistry, (2) polymer chemistry, (3) sol-gel chemistry, and (4) the ion-exchange principle. Organo-functionalized silanes, which serve as excellent coupling and dispersion agents, are incorporated into the optimized ISPC formula and evaluated using standard ASTM testing methods and electrochemical spectroscopy. Also, an ion-exchange pigment, which leads to better adhesion by forming a mixed metal silicate surface, is dispersed into an ISPC and the performance of the final coating formulation is evaluated. Successful ISPCs formulated for multiple coating systems exhibited excellent adhesion, hardness and gloss, which supports their suitability as a chrome-free, single-step alternative for aerospace, original equipment manufacturing (OEM) and coil coating applications.

  2. Toxicity and oxidative stress induced by chromium in workers exposed from different occupational settings around the globe: A review.

    PubMed

    Junaid, Muhammad; Hashmi, Muhammad Zaffar; Malik, Riffat Naseem; Pei, De-Sheng

    2016-10-01

    The present review focused on the levels and toxicological status of heavy metals especially chromium (Cr) in the exposed workers from different occupational settings around the globe and in Pakistan. It was found that exposed workers from leather tanning and metal plating units showed elevated levels of Cr than the workers from other occupational settings. Cr and other heavy metals level in biological matrices of the exposed workers in different occupational settings revealed that developing countries are severely contaminated. Occupational settings from the Sialkot district, Pakistan exhibited elevated level of Cr in biological entities of the exposed workers. Review suggested that higher level of Cr exposure to the workers enhance the oxidative stress (reactive oxygen species (ROS) and hydroxyl (OH) radical generation) which may cause; cellular and molecular damage such as genotoxicity and chromosomal aberration formations, and carcinogenic effects. This review will help to understand the Cr contamination mechanisms and associated health implications in different occupational settings around the globe in general and particularly to Pakistan. This study will also assist occupational health and safety management authorities to devise or change the Cr recommended exposure limits (REL) for different occupational settings.

  3. NASA and ESA Collaboration on Hexavalent Chrome Alternatives Pretreatments Only Interim Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt R.

    2015-01-01

    NASA and ESA continue to search for an alternative to hexavalent chromium in coatings applications that meet their performance requirements in corrosion protection, cost, operability, and health and safety, while typically specifying that performance must be equal to or greater than existing systems. The overall objective of the collaborative effort between NASA TEERM and ESA is to test and evaluate coating systems (pretreatments, pretreatments with primer, and pretreatments with primer and topcoat) as replacements for hexavalent chrome coatings in aerospace applications. This objective will be accomplished by testing promising coatings identified from previous NASA, ESA, Department of Defense (DOD), and other project experience. Additionally, several new materials will be analyzed according to ESA-identified specifications.

  4. Nucleotide sequence of Hungarian grapevine chrome mosaic nepovirus RNA1.

    PubMed Central

    Le Gall, O; Candresse, T; Brault, V; Dunez, J

    1989-01-01

    The nucleotide sequence of the RNA1 of hungarian grapevine chrome mosaic virus, a nepovirus very closely related to tomato black ring virus, has been determined from cDNA clones. It is 7212 nucleotides in length excluding the 3' terminal poly(A) tail and contains a large open reading frame extending from nucleotides 216 to 6971. The presumably encoded polyprotein is 2252 amino acids in length with a molecular weight of 250 kDa. The primary structure of the polyprotein was compared with that of other viral polyproteins, revealing the same general genetic organization as that of other picorna-like viruses (comoviruses, potyviruses and picornaviruses), except that an additional protein is suspected to occupy the N-terminus of the polyprotein. PMID:2798128

  5. Tribology of nitrided-coated steel-a review

    NASA Astrophysics Data System (ADS)

    Bhaskar, Santosh V.; Kudal, Hari N.

    2017-01-01

    Surface engineering such as surface treatment, coating, and surface modification are employed to increase surface hardness, minimize adhesion, and hence, to reduce friction and improve resistance to wear. To have optimal tribological performance of Physical Vapor Deposition (PVD) hard coating to the substrate materials, pretreatment of the substrate materials is always advisable to avoid plastic deformation of the substrate, which may result in eventual coating failure. The surface treatment results in hardening of the substrate and increase in load support effect. Many approaches aim to improve the adhesion of the coatings onto the substrate and nitriding is the one of the best suitable options for the same. In addition to tribological properties, nitriding leads to improved corrosion resistance. Often corrosion resistance is better than that obtainable with other surface engineering processes such as hard-chrome and nickel plating. Ability of this layer to withstand thermal stresses gives stability which extends the surface life of tools and other components exposed to heat. Most importantly, the nitrogen picked-up by the diffusion layer increases the rotating-bending fatigue strength in components. The present article reviews mainly the tribological advancement of different nitrided-coated steels based on the types of coatings, structure, and the tribo-testing parameters, in recent years.

  6. 75 FR 30434 - Stainless Steel Plate From Belgium, Italy, Korea, South Africa, and Taiwan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-01

    ... any, in the supply and demand conditions or business cycle for the Domestic Like Product that have... Official, at 202- 205-3088. Limited disclosure of business proprietary information (BPI) under an... producer, union/worker group, or trade/business association; import/export Subject Merchandise from more...

  7. KSC-03pd0936

    NASA Image and Video Library

    2003-04-01

    KENNEDY SPACE CENTER, FLA. - Workers add another base plate segment to the shrouded Space Infrared Telescope Facility. The base plate is being added for the canister. SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Most of this infrared radiation is blocked by the Earth's atmosphere and cannot be observed from the ground. Consisting of an 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF is one of NASA's largest infrared telescopes to be launched. SIRTF is currently scheduled for launch aboard a Delta II rocket from Launch Complex 17-B, Cape Canaveral Air Force Station.

  8. KSC-03pd0937

    NASA Image and Video Library

    2003-04-01

    KENNEDY SPACE CENTER, FLA. - Workers add another base plate segment to the shrouded Space Infrared Telescope Facility. The base plate is being added for the canister. SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Most of this infrared radiation is blocked by the Earth's atmosphere and cannot be observed from the ground. Consisting of an 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF is one of NASA's largest infrared telescopes to be launched. SIRTF is currently scheduled for launch aboard a Delta II rocket from Launch Complex 17-B, Cape Canaveral Air Force Station.

  9. Raman analysis of complex pigment mixtures in 20th century metal knight shields of the Order of the Elephant.

    PubMed

    Lauridsen, Clara Bratt; Sanyova, Jana; Simonsen, Kim Pilkjær

    2015-11-05

    The pigment composition of six painted metal knight shields of the Order of the Elephant dating from the second half of the 20th century belonging to the Danish royal collection were studied using Raman microscopy. By focusing a 785 nm laser with a 50× objective on particles in paint cross sections, it was possible to identify the following 20 compounds: hematite, goethite, chrome red/orange, chrome yellow, zinc chrome yellow, carbon black, toluidine red PR3, chlorinated para red PR4, dinitroaniline orange PO5, phthalocyanine blue PB15, indanthrone blue PB60, ultramarine, Prussian blue, lead white, anatase, rutile, calcium carbonate, barium sulphate, gypsum and dolomite. The components were frequently present in complex pigment mixtures. Additional information was obtained by elemental analysis with scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDX) to identify cobalt blue, zinc white and cadmium red, as well as to indicate the presence of zinc white in some pigment mixtures. The study allowed a comparison between the industrially applied preparation layers and the artistic paint layers applied by the heraldic painter. Differences in the choice of paint and pigment types were observed on the earliest knight shields, demonstrating a general delay of industrial materials into artist paints. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Dry etching of chrome for photomasks for 100-nm technology using chemically amplified resist

    NASA Astrophysics Data System (ADS)

    Mueller, Mark; Komarov, Serguie; Baik, Ki-Ho

    2002-07-01

    Photo mask etching for the 100nm technology node places new requirements on dry etching processes. As the minimum-size features on the mask, such as assist bars and optical proximity correction (OPC) patterns, shrink down to 100nm, it is necessary to produce etch CD biases of below 20nm in order to reproduce minimum resist features into chrome with good pattern fidelity. In addition, vertical profiles are necessary. In previous generations of photomask technology, footing and sidewall profile slope were tolerated, since this dry etch profile was an improvement from wet etching. However, as feature sizes shrink, it is extremely important to select etch processes which do not generate a foot, because this will affect etch linearity and also limit the smallest etched feature size. Chemically amplified resist (CAR) from TOK is patterned with a 50keV MEBES eXara e-beam writer, allowing for patterning of small features with vertical resist profiles. This resist is developed for raster scan 50 kV e-beam systems. It has high contrast, good coating characteristics, good dry etch selectivity, and high environmental stability. Chrome etch process development has been performed using Design of Experiments to optimize parameters such as sidewall profile, etch CD bias, etch CD linearity for varying sizes of line/space patterns, etch CD linearity for varying sizes of isolated lines and spaces, loading effects, and application to contact etching.

  11. Use of 2-octyl cyanoacrylate adhesive in rat liver induced lesion.

    PubMed

    Santos, Orlando José dos; Marques, Giancarlo de Souza; Sauaia Filho, Euler Nicolau; Frota, Gustavo Medeiros; Santos, Rayan Haquim Pinheiro; Santos, Rennan Abud Pinheiro

    2012-09-01

    To evaluate the healing process of rat traumatic liver lesion corrected with the use of 2-octyl cyanoacrylate adhesive, compared to the use of biologically absorbable chromed catgut thread suture. Thirty mail adult rats were divided into two groups (15 per group) according to the used method for liver lesion correction as follows: adhesive group (AG), and catgut group (CG); each group being divided into three subsets of five animals (7th, 14th, and 21st day), respectively, according to post-surgery evaluation. All animals were submitted to homogeneous lesion applying synthetic bonding to AG and using chromed catgut suture to CG for lesion correction. Macroscopic and microscopic parameters of healing processes were evaluated. Both groups of animals showed excellent abdominal wall healing, with no evidence of infection, and no abdominal cavity peritonitis or abscess. The presence of adherence was observed in both groups with no statistically significant difference. As to macroscopic evaluation, there was statistically significant difference with respect to specific factors of clinical inflammation (ischemic inflammation and giant celular inflammatory reaction) between animals evaluated on the 10th day (ischemic necrosis and giant cellular inflammatory reaction) among animals evaluated on the 14th day (A14 versus C14). Applying 2-octyl-cyanoacrylate adhesive for correcting rat liver lesion does not change healing process when compared to the use of chromed catgut stitch.

  12. Chrome-free Samarium-based Protective Coatings for Magnesium Alloys

    NASA Astrophysics Data System (ADS)

    Hou, Legan; Cui, Xiufang; Yang, Yuyun; Lin, Lili; Xiao, Qiang; Jin, Guo

    The microstructure of chrome-free samarium-based conversion coating on magnesium alloy was investigated and the corrosion resistance was evaluated as well. The micro-morphology, transverse section, crystal structure and composition of the coating were observed by scanning electron microscopy (SEM), X-ray diffraction (XRD), energy dispersive spectroscopy (EDS) and X- ray photoelectron spectroscopy (XPS), respectively. The corrosion resistance was evaluated by potentiodynamic polarization curve and electrochemical impedance spectroscopy (EIS). The results reveal that the morphology of samarium conversion coating is of crack-mud structure. Tiny cracks distribute in the compact coating deposited by samarium oxides. XRD, EDS and XPS results characterize that the coating is made of amorphous and trivalent-samarium oxides. The potentiodynamic polarization curve, EIS and OCP indicate that the samarium conversion coating can improve the corrosion resistance of magnesium alloys.

  13. Quaternized wood as sorbent for hexavalent chromium.

    PubMed

    Low, K S; Lee, C K; Lee, C Y

    2001-01-01

    The potential of quaternized wood (QW) chips in removing hexavalent chromium from synthetic solution and chrome waste under both batch and continuous-flow conditions was investigated. Sorption was found to be dependent on pH, metal concentration, and temperature. QW chips provide higher sorption capacity and wider pH range compared with untreated wood chips. The equilibrium data could be fitted into the Langmuir isotherm model, and maximum sorption capacities were calculated to be 27.03 and 25.77 mg/g in synthetic chromate solution and chrome waste, respectively. The presence of sulfate in high concentration appeared to suppress the uptake of chromium by QW chips. Column studies showed that bed depth influenced the breakthrough time greatly whereas flow rate of influent had little effect on its sorption on the column.

  14. Outbreak of invasive group A streptococcus: investigations using agar settle plates detect perineal shedding from a healthcare worker.

    PubMed

    Mahida, N; Prescott, K; Yates, C; Spencer, F; Weston, V; Boswell, T

    2018-03-29

    Outbreaks of group A streptococcus (GAS) infections may occur in healthcare settings. Transmission to patients is sometimes linked to colonized healthcare workers (HCWs) and/or a contaminated environment. To describe the investigation and control of an outbreak of healthcare-associated GAS on an elderly care medical ward, over six months. Four patients developed septicaemia due to GAS infection without a clinically obvious site of infection. The outbreak team undertook an investigation involving a retrospective review of GAS cases, prospective case finding, HCW screening and environmental sampling using both swabs and settle plates. Immediate control measures included source isolation and additional cleaning of the ward environment with a chlorine disinfectant and hydrogen peroxide. Prospective patient screening identified one additional patient with throat GAS carriage. Settle plate positivity for GAS was strongly associated with the presence of one individual HCW on the ward, who was subsequently found to have GAS perineal carriage. Contamination of a fabric-upholstered chair in an office adjacent to the ward, used by the HCW, was also detected. In total, three asymptomatic HCWs had throat GAS carriage and one HCW had both perineal and throat carriage. All isolates were typed as emm 28. This is the first outbreak report demonstrating the use of settle plates in a GAS outbreak investigation on a medical ward, to identify the likely source of the outbreak. Based on this report we recommend that both throat and perineal sites should be sampled if HCW screening is undertaken during an outbreak of GAS. Fabric, soft furnishings should be excluded from clinical areas as well as any adjacent offices because pathogenic bacteria such as GAS may contaminate this environment. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Substance use -- inhalants

    MedlinePlus

    ... blast, bold, chroming, discorama, glad, hippie crack, moon gas, oz, poor man's pot, rush, snappers, whippets, and ... computer cleaning spray, freon , helium, nitrous oxide (laughing gas), which is found in whipped cream containers, and ...

  16. Immune functions of the garment workers.

    PubMed

    Sultana, R; Ferdous, K J; Hossain, M; Zahid, M S H; Islam, L N

    2012-10-01

    Occupational exposure to cotton dust, fibers, metal fumes and different chemicals used in the aparrel manufacturing industries cause a wide range of physical and psychological health problems in the garment workers that may also affect their immune function. To assess the immune system function in garment workers. A total of 45 workers of a garment factory, and 41 control subjects, not exposed to the garment working environment were enrolled in this study. In the study subjects, the complement system function was assessed as bactericidal activity on Escherichia coli DH5α cells using the standard plate count method. Serum complement components C3 and C4 were measured by immunoprecipitation, and IgG was measured by immunonephelometry. The bactericidal activity of serum complement in the garment workers (range: 93.5%-99.9%) was significantly (p<0.01) lower than that in the controls (range: 98.6%-100%). The heat-inactivated serum of the workers showed a significantly enhanced bactericidal activity. In the garment workers, the mean levels of complement C3, and C4 were 1.75 and 0.26 g/L, respectively that were close to those of the controls. The mean IgG level in the garment workers was 13.5 g/L that was significantly (p<0.001) higher than that in the controls. Working in a garment factory may affect the immune system.

  17. Job Grading Standard for Electroplater, WG-3711.

    ERIC Educational Resources Information Center

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard for Electroplating Worker WG-7 and Electroplater WG-9 covers work involving the use of electrolytic and chemical processes to plate, coat, and treat surfaces of metals and metal alloys for purposes of protection, repair, maintenance, and fabrication of parts and equipment. A knowledge of the preparation, testing, and maintenance of…

  18. 40 CFR 763.122 - What does this subpart require me to do?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos Worker Protection § 763.122 What does this subpart... standards in 29 CFR 1910.1001. (c) Repair, cleaning, or replacement of asbestos-containing clutch plates and brake pads, shoes, and linings, or removal of asbestos-containing residue from brake drums or clutch...

  19. 40 CFR 763.122 - What does this subpart require me to do?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos Worker Protection § 763.122 What does this subpart... standards in 29 CFR 1910.1001. (c) Repair, cleaning, or replacement of asbestos-containing clutch plates and brake pads, shoes, and linings, or removal of asbestos-containing residue from brake drums or clutch...

  20. 40 CFR 763.122 - What does this subpart require me to do?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos Worker Protection § 763.122 What does this subpart... standards in 29 CFR 1910.1001. (c) Repair, cleaning, or replacement of asbestos-containing clutch plates and brake pads, shoes, and linings, or removal of asbestos-containing residue from brake drums or clutch...

  1. 40 CFR 763.122 - What does this subpart require me to do?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos Worker Protection § 763.122 What does this subpart... standards in 29 CFR 1910.1001. (c) Repair, cleaning, or replacement of asbestos-containing clutch plates and brake pads, shoes, and linings, or removal of asbestos-containing residue from brake drums or clutch...

  2. 40 CFR 763.122 - What does this subpart require me to do?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) TOXIC SUBSTANCES CONTROL ACT ASBESTOS Asbestos Worker Protection § 763.122 What does this subpart... standards in 29 CFR 1910.1001. (c) Repair, cleaning, or replacement of asbestos-containing clutch plates and brake pads, shoes, and linings, or removal of asbestos-containing residue from brake drums or clutch...

  3. Plating up Information Literacy as a Social Practice: A Slice of the Literature

    ERIC Educational Resources Information Center

    Fafeita, Jenny; Lloyd, Annemaree

    2012-01-01

    Few studies in the Library and Information Studies field investigate how vocational workers use information in their learning and workplace practice. This paper introduces doctoral research that explores how apprentice chefs develop information literacy practices that enable them to learn their trade and engage with the professional practices of…

  4. 75 FR 67108 - Cut-To-Length Carbon Steel Plate From India, Indonesia, Italy, Japan, and Korea

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-01

    ... and demand conditions or business cycle for the Domestic Like Product that have occurred in the United... Official, at 202-205-3088. Limited disclosure of business proprietary information (BPI) under an.../worker group, or trade/business association; import/export Subject Merchandise from more than one Subject...

  5. 76 FR 66684 - Foreign-Trade Zone 29-Louisville, KY, Application for Subzone; North American Stainless...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-27

    ...) include: fluorospar, molybdenum oxide, ferromanganese, ferrosilicon, ferrosilicon manganese, charge chrome... spent anodes, nickel, unwrought nickel alloys, aluminum, zinc, zinc alloys, manganese metal, titanium...

  6. 40 CFR 425.80 - Applicability; description of the pigskin subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Pigskin... into finished leather by chemically dissolving or pulping the hair and tanning with chrome, then retan...

  7. KSC-03pd0935

    NASA Image and Video Library

    2003-04-01

    KENNEDY SPACE CENTER, FLA. - A worker carries a base plate segment to the shrouded Space Infrared Telescope Facility. The base plate is being added for the canister. SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Most of this infrared radiation is blocked by the Earth's atmosphere and cannot be observed from the ground. Consisting of an 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF is one of NASA's largest infrared telescopes to be launched. SIRTF is currently scheduled for launch aboard a Delta II rocket from Launch Complex 17-B, Cape Canaveral Air Force Station.

  8. 40 CFR 425.70 - Applicability; description of the shearling subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Shearling... cured sheep or sheep-like skins with the wool or hair retained into finished leather by chrome tanning...

  9. NASA TEERM Principal Center Non-Chrome Projects

    NASA Technical Reports Server (NTRS)

    Rothgeb, Matthew

    2008-01-01

    Technology Evaluation for Environmental Risk Mitigation (TEERM) Principal Center Mission is to identify and validate environmental technologies through joint activities that enhance mission readiness and reduce risk while minimizing duplication and associated costs.

  10. Presidential Green Chemistry Challenge: 2013 Small Business Award

    EPA Pesticide Factsheets

    Presidential Green Chemistry Challenge 2013 award winner, Faraday Technology, Inc., process high-performance chrome coatings to be made from the less toxic, trivalent chromium. Reduce millions of pounds hexavalent chromium without comprising performance.

  11. Raman spectroscopy for the identification of pigments and color measurement in Dugès watercolors

    NASA Astrophysics Data System (ADS)

    Frausto-Reyes, C.; Ortiz-Morales, M.; Bujdud-Pérez, J. M.; Magaña-Cota, G. E.; Mejía-Falcón, R.

    2009-12-01

    Spectroscopic and colorimetric analysis of a representative set of Dugès watercolor paintings was performed. These paintings were the result of scientific studies carried out by the zoologist Alfredo Dugès, who recorded the fauna of the Mexican Republic between 1853 and 1910. Micro-Raman spectroscopy, with an excitation wavelength of 830 nm, and colorimetric techniques were employed in order to understand if different colors with the same hue were reproduced using the same pigments. The color coordinates of the measured areas were obtained in the CIE L* a* b* color space. Raman analysis showed that, in some cases, to reproduce colors with the same hue the pigment employed was not the same. Pigments identified in the watercolors were vermilion, carbon-based black, lead white, gamboge and chrome yellow, Prussian and ultramarine blue. Some of these pigments have been used since ancient times, others as Prussian blue, chrome yellow and synthetic ultramarine blue arrived to the market at the beginning of the 18th and 19th centuries, respectively. Furthermore, regarding the white color, instead of left the paper unpainted, lead white was detected in the eye of a bird. The green color was obtained by mixing Prussian blue with chrome yellow. The results of this work show the suitability of using Raman spectroscopy for watercolor pigment analysis and colorimetric techniques to measure the color of small areas (246 μm × 246 μm) that was the case for the lead white pigment.

  12. Is hand hygiene before putting on nonsterile gloves in the intensive care unit a waste of health care worker time?--a randomized controlled trial.

    PubMed

    Rock, Clare; Harris, Anthony D; Reich, Nicholas G; Johnson, J Kristie; Thom, Kerri A

    2013-11-01

    Hand hygiene (HH) is recognized as a basic effective measure in prevention of nosocomial infections. However, the importance of HH before donning nonsterile gloves is unknown, and few published studies address this issue. Despite the lack of evidence, the World Health Organization and other leading bodies recommend this practice. The aim of this study was to assess the utility of HH before donning nonsterile gloves prior to patient contact. A prospective, randomized, controlled trial of health care workers entering Contact Isolation rooms in intensive care units was performed. Baseline finger and palm prints were made from dominant hands onto agar plates. Health care workers were then randomized to directly don nonsterile gloves or perform HH and then don nonsterile gloves. Postgloving finger and palm prints were then made from the gloved hands. Plates were incubated and colony-forming units (CFU) of bacteria were counted. Total bacterial colony counts of gloved hands did not differ between the 2 groups (6.9 vs 8.1 CFU, respectively, P = .52). Staphylococcus aureus was identified from gloves (once in "hand hygiene prior to gloving" group, twice in "direct gloving" group). All other organisms were expected commensal flora. HH before donning nonsterile gloves does not decrease already low bacterial counts on gloves. The utility of HH before donning nonsterile gloves may be unnecessary. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  13. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sulfide in wastewaters discharged by plants operating in all subcategories except the hair save or pulp... by plants operating in the hair save or pulp, non-chrome tan, retan-wet finish subcategory (subpart C...

  14. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sulfide in wastewaters discharged by plants operating in all subcategories except the hair save or pulp... by plants operating in the hair save or pulp, non-chrome tan, retan-wet finish subcategory (subpart C...

  15. 40 CFR 425.03 - Sulfide analytical methods and applicability.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sulfide in wastewaters discharged by plants operating in all subcategories except the hair save or pulp... by plants operating in the hair save or pulp, non-chrome tan, retan-wet finish subcategory (subpart C...

  16. 40 CFR 63.340 - Applicability and designation of sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subject to this subpart. An example of such a tank is a chrome conversion coating tank where no electrical current is applied. (d) Affected sources in which research and laboratory operations are performed are...

  17. 40 CFR 63.340 - Applicability and designation of sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subject to this subpart. An example of such a tank is a chrome conversion coating tank where no electrical current is applied. (d) Affected sources in which research and laboratory operations are performed are...

  18. 40 CFR 63.340 - Applicability and designation of sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subject to this subpart. An example of such a tank is a chrome conversion coating tank where no electrical current is applied. (d) Affected sources in which research and laboratory operations are performed are...

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fruchter, Jonathan S.

    In Situ Treatment of Chromate Contaminated Groundwater Jonathan S. Fruchter Pacific Northwest National Laboratory Abstract of paper published in Environmental Science and Technology, 2002 Although not as common as solvent or fuel products contamination, chromate (chromium (VI)) contamination of groundwater is relatively widespread. Chromate has a variety of industrial uses, including chrome plating, steel making, and use as a corrosion inhibitor, wood preservative, well-drilling fluid additive, biocide, and as a pigment in paints and primers. EPA has estimated that as many as 1300 sites in the United States may have groundwater contaminated with chromate. The paper discusses a number ofmore » approaches to in situ treatment of chromate contamination in groundwater aquifers. The approaches include various types of chemical treatments, biological treatments and natural attenuation. The strengths and weaknesses of each method are discussed and compared. Field examples of two types of chemical treatment, in situ redox manipulation and chemically enhanced pump and treat are presented. It is concluded that in situ methods show promise, but can be difficult to implement due to site-specific conditions and limited long-term experience with these methods. As more performance and cost data are acquired for the demonstrations that are ongoing, and continuing research increases our understanding of subsurface processes, in situ treatment methods for chromium (VI) contamination in groundwater should gain wider acceptance.« less

  20. Reduction of hexavalent chromium collected on PVC filters.

    PubMed

    Shin, Y C; Paik, N W

    2000-01-01

    Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidation-reduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 approximately 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 approximately 89.9) at 1 hour and 81.0% (78.3 approximately 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 approximately 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  1. Chemistry and Artists' Colors: Part III. Preparation and Properties of Artists' Pigments.

    ERIC Educational Resources Information Center

    Orna, Mary Virginia

    1980-01-01

    Describes laboratory methods for synthesizing chrome yellow, prussian blue, and phthalalocyanine blue; reviews chemical properties of artists' pigments including chemical structure and light-scattering properties; and explains how pigments are classified. (CS)

  2. 30 CFR 50.20-6 - Criteria-MSHA Form 7000-1, Section C.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... as the first day of illness. (i) Code 21—Occupational Skin Diseases or Disorders. Examples: Contact dermatitis, eczema, or rash caused by primary irritants and sensitizers or poisonous plants; oil acne; chrome...

  3. A sharp knife for high temperatures

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.

    1978-01-01

    Electrically heated nickel-chrome-steel alloy knife may be used to cut heat resistant plastic felt and similar materials with relative ease. Blade made of commercially available alloy RA 330 retains edge at temperatures as high as 927 C.

  4. Elemental composition of airborne dust in the Shale Shaker House during an offshore drilling operation.

    PubMed

    Hansen, A B; Larsen, E; Hansen, L V; Lyngsaae, M; Kunze, H

    1991-12-01

    During 2 days of an offshore drilling operation in the North Sea, 16 airborne dust samples from the atmosphere of the Shale Shaker House were collected onto filters. During this operation, drilling mud composed of a water slurry of barite (BaSO4) together with minor amounts of additives, among them chrome lignosulphonate and chrome lignite, was circulated between the borehole and the Shale Shaker House. The concentration of airborne dust in the atmosphere was determined and the elemental composition of the particles analysed by both PIXE (proton-induced X-ray emission) and ICP-MS (inductively coupled plasma-mass spectrometry). The total amount of dust collected varied from 0.04 to 1.41 mg m-3 with barium (Ba) as the single most abundant element. The open shale shakers turned out to be the major cause of generation of dust from the solid components of the drilling mud.

  5. Enhancing Surface Finish of Additively Manufactured Titanium and Cobalt Chrome Elements Using Laser Based Finishing

    NASA Astrophysics Data System (ADS)

    Gora, Wojciech S.; Tian, Yingtao; Cabo, Aldara Pan; Ardron, Marcus; Maier, Robert R. J.; Prangnell, Philip; Weston, Nicholas J.; Hand, Duncan P.

    Additive manufacturing (AM) offers the possibility of creating a complex free form object as a single element, which is not possible using traditional mechanical machining. Unfortunately the typically rough surface finish of additively manufactured parts is unsuitable for many applications. As a result AM parts must be post-processed; typically mechanically machined and/or and polished using either chemical or mechanical techniques (both of which have their limitations). Laser based polishing is based on remelting of a very thin surface layer and it offers potential as a highly repeatable, higher speed process capable of selective area polishing, and without any waste problems (no abrasives or liquids). In this paper an in-depth investigation of CW laser polishing of titanium and cobalt chrome AM elements is presented. The impact of different scanning strategies, laser parameters and initial surface condition on the achieved surface finish is evaluated.

  6. The Evaluation of a Modified Chrome Oxide Based High Temperature Solid Lubricant Coating for Foil Gas Bearings

    NASA Technical Reports Server (NTRS)

    DellaCorte, Chris

    1998-01-01

    This paper describes the friction and wear performance of PS304, a modified chrome oxide based coating, for foil gas bearings. PS304 contains 60 wt% NiCr binder, 20 wt% Cr2O3 hardener, and 10 wt% each Ag, and BaF2/CaF2 lubricants. For evaluation, the coating is plasma spray deposited onto test journals which are slid against a superalloy partial arc foil bearing. The test load was 10 KPa (1.5 psi) and the bearings were run under start/stop cyclic conditions. The data show good wear performance of the bearing, especially at temperatures above 25 deg. C. Bearing friction was moderate (micron approx. or equal to 0.4) over the entire temperature range. Based upon the results obtained, the PS304 coating has promise for high temperature, oil-free turbomachinery applications.

  7. Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants.

    PubMed

    Bolstad, Kirsten; Flatabø, Silje; Aadnevik, Daniel; Dalehaug, Ingvild; Vetti, Nils

    2018-01-01

    Background Metal implants may introduce severe artifacts in computed tomography (CT) images. Over the last few years dedicated algorithms have been developed in order to reduce metal artifacts in CT images. Purpose To investigate and compare metal artifact reduction algorithms (MARs) from four different CT vendors when imaging three different orthopedic metal implants. Material and Methods Three clinical metal implants were attached to the leg of an anthropomorphic phantom: cobalt-chrome; stainless steel; and titanium. Four commercial MARs were investigated: SmartMAR (GE); O-MAR (Philips); iMAR (Siemens); and SEMAR (Toshiba). The images were evaluated subjectively by three observers and analyzed objectively by calculating the fraction of pixels with CT number above 500 HU in a region of interest around the metal. The average CT number and image noise were also measured. Results Both subjective evaluation and objective analysis showed that MARs reduced metal artifacts and improved the image quality for CT images containing metal implants of steel and cobalt-chrome. When using MARs on titanium, all MARs introduced new visible artifacts. Conclusion The effect of MARs varied between CT vendors and different metal implants used in orthopedic surgery. Both in subjective evaluation and objective analysis the effect of applying MARs was most obvious on steel and cobalt-chrome implants when using SEMAR from Toshiba followed by SmartMAR from GE. However, MARs may also introduce new image artifacts especially when used on titanium implants. Therefore, it is important to reconstruct all CT images containing metal with and without MARs.

  8. Mercury Poisoning from an Unsuspected Source

    PubMed Central

    Tamir, M.; Bornstein, B.; Behar, M.; Chwat, M.

    1964-01-01

    In the manufacture of zinc oxide the raw material normally used in zinc metal plates. In a factory in which old aeroplane batteries containing zinc mercury amalgam were substituted, it was not realized that mercury vapour was being produced. Of 25 workers exposed, seven developed serious chronic mercury poisoning and were admitted to hospital. The clinical findings in the affected workers are described. They were first treated with penicillamine D, but in all but one case this had to be stopped because of rashes. Little improvement followed a switch to B.A.L. It is suggested that if penicillamine D is used in the treatment of mercury poisoning, steroid cover should be given from the start. PMID:14249900

  9. NASA and ESA Collaboration on Hexavalent Chrome Alternatives - Pretreatments with Primers Screening Final Test Report

    NASA Technical Reports Server (NTRS)

    Rothgeb, Matthew J.; Kessel, Kurt R.

    2015-01-01

    Hexavalent chromium (hex chrome or Cr(VI)) is a widely used element within applied coating systems because of its self-healing and corrosion-resistant properties. The replacement of hex chrome in the processing of aluminum for aviation and aerospace applications remains a goal of great significance. Aluminum is the major manufacturing material of structures and components in the space flight arena. The National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA) are engaged in a collaborative effort to test and evaluate alternatives to hexavalent chromium containing corrosion coating systems. NASA and ESA share common risks related to material obsolescence associated with hexavalent chromium used in corrosion-resistant coatings. In the United States, Occupational Safety and Health Administration (OSHA) studies have concluded that hexavalent chromium is carcinogenic and poses significant risk to human health. On May 5, 2011, amendments to the Defense Federal Acquisition Regulation Supplement (DFARS) were issued in the Federal Register. Subpart 223.73 prohibits contracts from requiring hexavalent chromium in deliverables unless certain exceptions apply. Subpart 252.223-7008 provides the contract clause prohibiting contractors and subcontractors from using or delivering hexavalent chromium in a concentration greater than 0.1 percent by weight for all new contracts associated with supplies, maintenance and repair services, and construction materials. ESA faces its own increasingly stringent regulations within European directives such as Registration, Evaluation, Authorization and Restriction of Chemical (REACH) substances and the Restriction of Hazardous Substances Directive (RoHS) which have set a mid-2017 sunset date for hexavalent chromium. NASA and ESA continue to search for an alternative to hexavalent chromium in coatings applications that meet their performance requirements in corrosion protection, cost, operability, and health and safety, while typically specifying that performance must be equal to or greater than existing systems. The overall objective of the collaborative effort between NASA TEERM and ESA is to test and evaluate coating systems (pretreatments, pretreatments with primer, and pretreatments with primer and topcoat) as replacements for hexavalent chrome coatings in aerospace applications. This objective will be accomplished by testing promising coatings identified from previous NASA, ESA, Department of Defense (DOD), and other project experience. Additionally, several new materials will be analyzed according to ESA-identified specifications.

  10. Absorptive coating for aluminum solar panels

    NASA Technical Reports Server (NTRS)

    Desmet, D.; Jason, A.; Parr, A.

    1979-01-01

    Method for coating forming coating of copper oxide from copper component of sheet aluminum/copper alloy provides strong durable solar heat collector panels. Copper oxide coating has solar absorption characteristics similar to black chrome and is much simpler and less costly to produce.

  11. 40 CFR 60.260 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... affected facility. 60.260 Section 60.260 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Ferroalloy Production Facilities § 60.260 Applicability and designation of affected facility..., ferrochrome silicon, silvery iron, high-carbon ferrochrome, charge chrome, standard ferromanganese...

  12. 40 CFR 60.260 - Applicability and designation of affected facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... affected facility. 60.260 Section 60.260 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Performance for Ferroalloy Production Facilities § 60.260 Applicability and designation of affected facility..., ferrochrome silicon, silvery iron, high-carbon ferrochrome, charge chrome, standard ferromanganese...

  13. Global Plate Motions Relative to the Hotspots since 48 Ma B.P. from Simultaneous Inversion of Hotspot Tracks in the Pacific, Indian, and Atlantic Oceans Constrained to Consistency with Known Relative Plate Motions

    NASA Astrophysics Data System (ADS)

    Gordon, R. G.; Koivisto, E. A. L.

    2016-12-01

    A fundamental problem of global tectonics and paleomagnetism is determining what part of apparent polar wander is due to plate motion and what part is due to true polar wander. One approach for separating these is available if global hotspots can be used as a reference frame approximately fixed with respect to the deep mantle. Some other workers have used a hotspot reference based only on tracks in the Atlantic and Indian Oceans, and some have used reference frames with moving hotspots and many adjustable parameters. In sharp contrast to the assumptions made in these other works, our recent results demonstrate that there is no significant motion between the Pacific and Indo-Atlantic hotspots since 48 Ma B.P. (lower bound of zero and upper bound of 8-13 mm/yr [Koivisto et al., 2014]). Corrected methodologies combined with cumulative improvements in the age progression along the hotspot tracks, the geomagnetic reversal time scale, and relative plate reconstructions lead to significantly lower rates of motion between hotspots than found in prior studies. Building on our prior results, here we present a globally self-consistent estimate of plate motions relative to the hotspots for the past 48 million years from inversions to fit simultaneously the tracks of the Hawaiian, Louisville, Tristan da Cunha, Réunion, and Iceland hotspots constrained to consistency with known relative plate motions. Each finite rotation is estimated for an age corresponding to a key magnetic anomaly used in plate reconstructions. The new set of plate reconstructions presented here provides a firm basis for estimating absolute plate motions for the past 48 million years and, in particular, can be used to separate paleomagnetically determined apparent polar wander into the part due to plate motion and the part due to true polar wander. Implications for true polar wander since the age of the Hawaiian-Emperor Bend will be discussed.

  14. USE OF FUME SUPPRESSANTS IN HARD CHROMIUM BATHS - EMISSION TESTING

    EPA Science Inventory

    The EPA Common Sense Initiative (CSI) is a cooperative effort of government, industry, environmental, and other stakeholder groups to find "cleaner, cheaper, smarter" approaches to environmental management in industrial sectors. The purpose of the project is to assist hard chrome...

  15. Comparative Study Between Cobalt Chrome and Titanium Alloy Rods for Multilevel Spinal Fusion: Proximal Junctional Kyphosis More Frequently Occurred in Patients Having Cobalt Chrome Rods.

    PubMed

    Han, Sanghyun; Hyun, Seung-Jae; Kim, Ki-Jeong; Jahng, Tae-Ahn; Kim, Hyun-Jib

    2017-07-01

    The use of titanium alloy (Ti) rods is frequently associated with rod fracture after spinal fixation. To address this issue, cobalt chrome (CoCr) rods, which are advantageous because of their greater strength and resistance to fatigue relative to Ti rods, have been introduced. The purpose of the present study was to compare radiographic outcomes after the use of Ti versus CoCr rods in a matched cohort of patients undergoing posterior spinal fusion for treatment of spinal instability. We retrospectively reviewed data from patients who had undergone spinal fusion involving more than 3 levels at a single institution between 2004 and 2015. Patients were matched for age, diagnosis, 3-column osteotomy, levels fused, and T score. Fifty patients with Ti rods were identified and appropriately matched to 50 consecutive patients with CoCr rods. The distributions of age at surgery, sex, diagnosis, 3-column osteotomy, levels fused, number of patients with previous surgical procedures, and T score did not significantly differ between the 2 groups. However, there were significant differences in length of follow-up (CoCr, 25.0 vs. Ti, 28.5 months; P < 0.001), fusion rate (CoCr, 45 [90%] vs. Ti, 33 [66%]; P = 0.004), occurrence of rod breakage (CoCr, 0 vs. T, 8 [16%]; P = 0.006), and junctional kyphosis (CoCr, 24 [46%] vs. Ti, 9 [18%]; P = 0.003). Our findings indicate that the use of CoCr rods is effective in ensuring stability of the posterior spinal construct and accomplishment of spinal fusion. Furthermore, our results indicate that junctional kyphosis may occur more frequently in CoCr systems than in Ti systems. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Hexavalent Chrome Free Coatings for Electronics Applications: Joint Test Report

    NASA Technical Reports Server (NTRS)

    Kessel, Kurt

    2012-01-01

    Regardless of the corrosivity of the environment, all metals require periodic maintenance activity to guard against the insidious effects of corrosion and thus ensure that alloys meet or exceed design or performance life. The standard practice for protecting metallic substrates is the application of a coating system. Applied coating systems work via a variety of methods (barrier, galvanic, and/or inhibitor) and adhere to the substrate through a combination of chemical and physical bonds. For years hexavalent chromium has been a widely used element within applied coating systems because of its self healing and corrosion resistant properties. Occupational Safety and Health Administration (OSHA) studies have concluded that hexavalent chromium (hex chrome) is carcinogenic and poses significant risk to human health. On May 5, 2011 amendments to the Defense Federal Acquisition Regulation Supplement (DFARS) were issued in the Federal Register. Subpart 223.73 prohibits contracts from requiring hexavalent chromium in deliverables unless certain exceptions apply. These exceptions include authorization from a general or flag officer and members of the Senior Executive Service from a Program Executive Office, and unmodified legacy systems. Otherwise, Subpart 252.223-7008 provides the contract clause prohibiting contractors from using or delivering hexavalent chromium in a concentration greater than 0.1 percent by weight for all new contracts and to be included down to subcontractors for supplies, maintenance and repair services, and construction materials. National Aeronautics and Space Administration (NASA), Department of Defense (DoD), and industry stakeholders continue to search for alternatives to hex chrome in coatings applications that meet their performance requirements in corrosion protection, cost, operability, and health and safety, while typically specifying that performance must be equal to or greater than existing systems.

  17. Biointervention makes leather processing greener: an integrated cleansing and tanning system.

    PubMed

    Thanikaivelan, Palanisamy; Rao, Jonnalagadda Raghava; Nair, Balachandran Unni; Ramasami, Thirumalachari

    2003-06-01

    The do-undo methods adopted in conventional leather processing generate huge amounts of pollutants. In other words, conventional methods employed in leather processing subject the skin/hide to wide variations in pH. Pretanning and tanning processes alone contribute more than 90% of the total pollution from leather processing. Included in this is a great deal of solid wastes such as lime and chrome sludge. In the approach described here, the hair and flesh removal as well as fiber opening have been achieved using biocatalysts at pH 8.0 for cow hides. This was followed by a pickle-free chrome tanning, which does not require a basification step. Hence, this tanning technique involves primarily three steps, namely, dehairing, fiber opening, and tanning. It has been found that the extent of hair removal, opening up of fiber bundles, and penetration and distribution of chromium are comparable to that produced by traditional methods. This has been substantiated through scanning electron microscopic, stratigraphic chrome distribution analysis, and softness measurements. Performance of the leathers is shown to be on par with conventionally processed leathers through physical and hand evaluation. Importantly, softness of the leathers is numerically proven to be comparable with that of control. The process also demonstrates reduction in chemical oxygen demand load by 80%, total solids load by 85%, and chromium load by 80% as compared to the conventional process, thereby leading toward zero discharge. The input-output audit shows that the biocatalytic three-step tanning process employs a very low amount of chemicals, thereby reducing the discharge by 90% as compared to the conventional multistep processing. Furthermore, it is also demonstrated that the process is technoeconomically viable.

  18. Machine Gun Liner Bond Strength

    DTIC Science & Technology

    2007-08-01

    explosive bonding of pure tantalum, several tantalum alloys, and Stellite 25 (an alloy of cobalt, chrome , nickel, and tungsten) in a liner...smoothly as elastic stresses increase in the plug and liner. At a certain level of displacement, the load reaches a peak and then drops sharply. The

  19. 40 CFR 425.60 - Applicability; description of the through-the-blue subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY... processes raw or cured cattle or cattle-like hides through the blue tanned state by hair pulp unhairing and chrome tanning; no retan-wet finishing is performed. ...

  20. HARD CHROME POLLUTION PREVENTION DEMONSTRATION PROJECT - INTERIM REPORT

    EPA Science Inventory

    In the project, five chromium emission prevention/control devices were tested tha cover the spectrum of prevention/control techniques currently in use in small- and large-size hard chromium electroplating job shops. The Project results show that some of the tested devices had ch...

  1. 40 CFR 425.24 - New source performance standards (NSPS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome...

  2. 40 CFR 425.14 - New source performance standards (NSPS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome...

  3. 40 CFR 425.24 - New source performance standards (NSPS).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome...

  4. 40 CFR 425.14 - New source performance standards (NSPS).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome...

  5. 40 CFR 425.24 - New source performance standards (NSPS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome...

  6. 40 CFR 425.14 - New source performance standards (NSPS).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome...

  7. 40 CFR 415.344 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for existing... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Chrome Pigments Production Subcategory § 415.344 Pretreatment standards for existing sources (PSES). (a) Existing...

  8. Recycling of Chrome Tanned Leather Dust in Acrylonitrile Butadiene Rubber

    NASA Astrophysics Data System (ADS)

    El-Sabbagh, Salwa H.; Mohamed, Ola A.

    2010-06-01

    Concerns on environmental waste problem caused by chrome tanned leather wastes in huge amount have caused an increasing interest in developing this wastes in many composite formation. This leather dust was used as filler in acrylonitrile butadiene rubber (NBR) before treatment and after treatment with ammonia solution and sod. formate. Different formulations of NBR/ leather dust (untreated-treated with ammonia solution—treated with sod. formate) composites are prepared. The formed composite exhibit a considerable improvement in some of their properties such as rheometric characteristics especially with composites loaded with treated leather dust. Tensile strength, modulus at 100% elongation, hardness and youngs modulus were improved then by further loading start to be steady or decrease. Cross linking density in toluene were increased by incorporation of leather dust treated or untreated resulting in decreases in equilibrium swelling. Distinct increase in the ageing coefficient of both treated and untreated leather with drop in NBR vulcanizates without leather dust. Addition of leather dust treated or untreated exhibit better thermal stability.

  9. Tribological evaluation of PS300: A new chrome oxide based solid lubricant coating sliding against Al2O3 From 25 to 650 C

    NASA Technical Reports Server (NTRS)

    DellaCorte, C.; Laskowski, J. A.

    1996-01-01

    This paper presents the tribological characteristics of Al203 sliding against PS300; a chrome oxide based self lubricating coating. Al203 pins were slid against PS300 coated superalloy disks in air, under a 4.9 N load at velocities of 1 to 8 m/s. At a sliding velocity of 1 m/s, friction ranged from 0.6 at 25 C to 0.2 at 650 C. Wear factors for the Al203 pins were in the 10(exp -7) mm(exp 3)/N-m range and for the PS300 coating was in the 10(exp -5) mm(exp 3)/N-m range. The test results suggest that increased surface temperature resulting from either frictional heating, generated by increased sliding velocity, or ambient heating caused a reduction in friction and wear of the sliding couple. Based upon these results, the tested material combination is a promising candidate for high temperature wear applications.

  10. Revision of Articular Surface Replacement (ASR) Total Hip Arthroplasty: Correlation of Perioperative Data and Early Post-Revision Outcome Results.

    PubMed

    Cip, Johannes; Bach, Christian; Widemschek, Mark; Luegmair, Matthias; Martin, Arno

    2015-09-01

    The articular surface replacement (ASR) total hip arthroplasty (THA) showed accelerated failure rates due to adverse-reaction to metal debris (ARMD). Literature correlating preoperative with intraoperative revision findings respectively post-revision outcome results are rare. 30 of 99 available ASR THA were revised due to ARMD. Mean post-revision follow-up term was 2.3 years. In part, preoperative data did not correlate with intraoperative revision findings. ARMD was even found in asymptomatic patients with non-elevated ion levels. Postoperative pain and metal ions decreased significantly (P ≤ 0.016). Cobalt decreased faster than chrome. Patients with intraoperative pseudotumors, osteolysis or bilateral THA did not have higher pre- or postoperative ion values (P ≥ 0.053). Females showed higher postoperative chrome levels (P=0.031). One major post-revision complication (femoral nerve palsy) and one re-revision (late onset infection) occurred. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Development of thermal model to analyze thermal flux distribution in thermally enhanced machining of high chrome white cast iron

    NASA Astrophysics Data System (ADS)

    Ravi, A. M.; Murigendrappa, S. M.

    2018-04-01

    In recent times, thermally enhanced machining (TEM) slowly gearing up to cut hard metals like high chrome white cast iron (HCWCI) which were impossible in conventional procedures. Also setting up of suitable cutting parameters and positioning of the heat source against the work appears to be critical in order to enhance the machinability characteristics of the work material. In this research work, the Oxy - LPG flame was used as the heat source and HCWCI as the workpiece. ANSYS-CFD-Flow software was used to develop the transient thermal model to analyze the thermal flux distribution on the work surface during TEM of HCWCI using Cubic boron nitride (CBN) tools. Non-contact type Infrared thermo sensor was used to measure the surface temperature continuously at different positions, and is validated with the thermal model results. The result confirms thermal model is a better predictive tool for thermal flux distribution analysis in TEM process.

  12. A novel detection approach based on chromophore-decolorizing with free radical and application to photometric determination of copper with acid chrome dark blue.

    PubMed

    Gao, Hong-Wen; Chen, Fang-Fang; Chen, Ling; Zeng, Teng; Pan, Lu-Ting; Li, Jian-Hua; Luo, Hua-Fei

    2007-03-21

    A novel detection approach named chromophore-decolorizing with free radicals is developed for determination of trace heavy metal. The hydroxyl radicals (HO) generated from Fe(III) and hydrogen peroxide will oxidize the free chromophore into almost colorless products. The copper-acid chrome dark blue (ACDB) complexation was investigated at pH 5.07. In the presence of Fe(III) and hydrogen peroxide, the excess ACDB was decolorized in the Cu-ACDB reaction solution, and the final solution contained only one color compound, the Cu-ACDB complex. After oxidation of free hydroxyl radicals, the complexation becomes sensitive and selective and it has been used for the quantitation of trace amounts of Cu(II) dissolved in natural water. Beer's law is obeyed in the range from 0 to 0.500 microg mL(-1) Cu(II) and the limit of detection is only 6 microg L(-1) Cu(II). Besides, the Cu-ACDB complex formed was characterized.

  13. [Study on hydrothermal stability of the collagen].

    PubMed

    Wang, Yajuan; Chen, Hui; Shan, Zhihua

    2009-02-01

    The low hydrothermal stability of the raw collagen restricts its usage. To improve the hydrothermal stability of collagen, two kinds of materials with weak astringency were used by experts. The research proved that the synergistic effect was formed during the process. In this study, by using UV, FT-IR, 13CNMR spectra and elemental analysis on the salicylic acid and metal-salicylic complexes, we could get the structural formula of every compound. And then, the hide powder was treated with the compounds. At last, the treated hide powder was tested by DSC. It could be presumed that the Rigid Matrix formed between the collagen doses can increase the hydrothermal stability of raw collagen, The result indicated that salicylic-chrome with large stable constant was better than others in improving the heat resistance of raw collagen, and the denaturalization temperature of hide powder treated with salicylic-chrome was 146.7 degrees C. Salicylic-aluminum was in the second place, the relevant temperature being 145.7 degrees C.

  14. Spherical grating monochromator with interferometer control and in-vacuum reference

    NASA Astrophysics Data System (ADS)

    Holly, D. J.; Mason, W. P.; Sailor, T.; Smith, R. E.; Wahl, D.

    2002-03-01

    Physical Science Laboratory's new generation of spherical grating monochromators incorporates a laser interferometer to control scan angle and an in-vacuum absolute angle reference, as well as other improvements. The design accommodates up to six gratings which can be moved axially (under motor control, with encoder position readback) at any scan angle. The gratings are cooled by means of spring-loaded clamps which conduct heat to a water-cooled plate. The instruments feature hollow roller bearings on the scan axis to minimize bearing runout, and a pseudosine-bar drive for precise control of grating angle. The interferometer angle-measuring optics are mounted inside the vacuum chamber and measure the angle between the grating scan axis and the instrument's granite base. The laser interferometer measures the grating angle with a resolution of approximately 0.02 arcsec over the entire scan range of 40°. To provide a reference for the interferometer angle measurement, we have built an in-vacuum optical reference which uses custom chrome-on-glass reticles mounted inside the vacuum chamber. Collimated light from a source outside the vacuum passes through the reticles to yield quadrature signals which precisely define an absolute reference angle for the interferometer. Repeatability of the grating angle is within a range of ±0.05 arcsec. Two of these instruments are in operation at SRRC (Taiwan) and a third instrument has been delivered to NSLS (Brookhaven).

  15. REAP (raster e-beam advanced process) using 50-kV raster e-beam system for sub-100-nm node mask technology

    NASA Astrophysics Data System (ADS)

    Baik, Ki-Ho; Dean, Robert L.; Mueller, Mark; Lu, Maiying; Lem, Homer Y.; Osborne, Stephen; Abboud, Frank E.

    2002-07-01

    A chemically amplified resist (CAR) process has been recognized as an approach to meet the demanding critical dimension (CD) specifications of 100nm node technology and beyond. Recently, significant effort has been devoted to optimizing CAR materials, which offer the characteristics required for next generation photomask fabrication. In this paper, a process established with a positive-tone CAR from TOK and 50kV MEBES eXara system is discussed. This resist is developed for raster scan 50 kV e-beam systems. It has high contrast, good coating characteristics, good dry etch selectivity, and high environmental stability. The coating process is conducted in an environment with amine concentration less than 2 ppb. A nitrogen environment is provided during plate transfer steps. Resolution using a 60nm writing grid is 90nm line and space patterns. CD linearity is maintained down to 240nm for isolated lines or spaces by applying embedded proximity effect correction (emPEC). Optimizations of post-apply bake (PAB) and post-expose bake (PEB) time, temperature, and uniformity are completed to improve adhesion, coating uniformity, and resolution. A puddle develop process is optimized to improve line edge roughness, edge slope, and resolution. Dry etch process is optimized on a TetraT system to transfer the resist image into the chrome layer with minimum etch bias.

  16. Observing the Sun with micro-interferometric devices: a didactic experiment

    NASA Astrophysics Data System (ADS)

    Defrère, D.; Absil, O.; Hanot, C.; Riaud, P.; Magette, A.; Marion, L.; Wertz, O.; Finet, F.; Steenackers, M.; Habraken, S.; Surdej, A.; Surdej, J.

    2014-04-01

    Measuring the angular diameter of celestial bodies has long been the main purpose of stellar interferometry and was its historical motivation. Nowadays, stellar interferometry is widely used for various other scientific purposes that require very high angular resolution measurements. In terms of angular spatial scales probed, observing distant stars located 10 to 100~pc away with a large hectometric interferometer is equivalent to observing our Sun with a micrometric baseline. Based on this idea, we have manufactured a set of micro-interferometric devices and tested them on the sky. The micro-interferometers consist of a chrome layer deposited on a glass plate that has been drilled by laser lithography to produce micron-sized holes with configurations corresponding to proposed interferometer projects such as CARLINA, ELSA, KEOPS, and OVLA. In this paper, we describe these interferometric devices and present interferometric observations of the Sun made in the framework of Astrophysics lectures being taught at the Liège University. By means of a simple photographic camera placed behind a micro-interferometric device, we observed the Sun and derived its angular size. This experiment provides a very didactic way to easily obtain fringe patterns similar to those that will be obtained with future large imaging arrays. A program written in C also allows to reproduce the various point spread functions and fringe patterns observed with the micro-interferometric devices for different types of sources, including the Sun.

  17. Testing palaeotectonic models for the Internal Hellenides with sediment provenance

    NASA Astrophysics Data System (ADS)

    Meinhold, G.

    2009-04-01

    The Internal Hellenides of Greece are a result of the Alpine-Himalayan orogen. The relationships between different pre-Alpine crustal fragments of the Internal Hellenides are now masked by younger (Mesozoic to Cenozoic) complex structural and metamorphic events. This, together with the scarcity of biostratigraphic, geochronological and palaeomagnetic data, has given rise to equivocal palaeotectonic models and interpretations. However, the age and origin of pre-Alpine basement units in the Internal Hellenides has important implications for our in-depth understanding of the evolution of North Gondwana-derived terranes and consequently for alternative palaeotectonic reconstructions for the Palaeozoic and Mesozoic. A multidisciplinary sediment provenance study was undertaken since sedimentary rocks can provide information about rock lithologies in the source area, which have often been destroyed and recycled during ancient plate tectonic processes. Palaeozoic and Mesozoic sedimentary rocks from key areas of the Internal Hellenides were analysed using whole-rock major- and trace-element geochemistry (XRF, ICPMS), detrital chrome spinel, garnet, white mica and rutile chemistry (EMP), detrital zircon geochronology (SHRIMP, LA-ICPMS) and biostratigraphic analysis. These new data are used to constrain terrane accretion processes and the provenance of crustal sources for sediments during Palaeozoic and Mesozoic times and thus will test palaeotectonic models for the Internal Hellenides. This is expected to shed light on the Palaeo- and Neotethyan evolution in the Eastern Mediterranean.

  18. A new approach to isolating siderophore-producing actinobacteria.

    PubMed

    Nakouti, I; Sihanonth, P; Hobbs, G

    2012-07-01

    This study was conducted to investigate the application of 2,2'-dipyridyl as a new approach to isolating siderophore-producing actinobacteria. Isolation of actinobacteria from soil was conducted by a soil dilution plate technique using starch-casein agar. Iron starvation was fostered by the incorporation of the iron chelator 2,2'-dipyridyl in the isolation medium. Pretreatment of the samples at an elevated temperature (40°C) ensured that the majority of nonsporulating bacteria were excluded. The survivors of this treatment were largely actinobacteria. Of the viable cultures grown in the presence of 2,2'-dipyridyl, more than 78-88% (average of three separate studies) were reported to produce siderophore-like compounds compared to 13-18% (average of three separate studies) when grown on the basic media in the absence of the chelating agent. The most prolific producers as assessed by the chrome azurol sulphate (CAS) assay were further characterized and found to belong to the genus Streptomyces. Selective pressure using 2,2'-dipyridyl as an iron-chelating agent in starch-casein media increased the isolation of siderophore-producing actinobacteria compared to the unamended medium. The study described represents a new approach to the isolation of siderophore-producing actinobacteria using a novel procedure that places a selection on cell population based upon the incorporation of a chelating agent in the medium. © 2012 The Authors. Letters in Applied Microbiology © 2012 The Society for Applied Microbiology.

  19. Surveillance of nosocomial infections: a preliminary study on hand hygiene compliance of healthcare workers.

    PubMed

    Brunetti, L; Santoro, E; De Caro, F; Cavallo, P; Boccia, G; Capunzo, M; Motta, O

    2006-06-01

    The observance of hand hygiene compliance is important to reduce cross-infection by micro-organisms. The aim of this preliminary study was to evaluate the level of hand hygiene in healthcare workers from different departments, with particular emphasis on transient flora. The study was conducted in three departments (Surgery, Intensive Care Unit, Obstetrics and Gynecology) of a hospital in Campania, southern Italy. Over a six-month period, 50 healthcare workers were randomly tested. Imprints of palms and fingertips were taken monthly during the morning shift. The number of colonies per plate was counted and transient pathogens were identified. Risk factors for hand contamination were determined. Total flora was found in the following CFU means per palm and per five fingertips (95% CI): Obstetrics and Gynecology [palms 130 CFUs (95% CI 85-180); fingertips 125 CFUs (95% CI 92-160)]; ICU [palms 80 CFUs (95% CI 58-99); fingertips 62 CFUs (95% CI 45-82)]; Surgery [palms 75 CFUs (95% CI 41-120); fingertips 70 CFUs (95% CI 52-90)] Transient flora was found on 39% of healthcare workers' hands. The only factor associated with hand contamination by transient flora was the absence of gloving during healthcare procedure (P = 0.02).

  20. 40 CFR 261.32 - Hazardous wastes from specific sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../or pigments production is defined to include manufacture of the following product classes: dyes... pentachlorophenol (T) Inorganic pigments: K002 Wastewater treatment sludge from the production of chrome yellow and orange pigments (T) K003 Wastewater treatment sludge from the production of molybdate orange pigments (T...

  1. Molecular modeling approach to vegetable tanning: preliminary results for gallotannin interactions with the collagen microfibril

    USDA-ARS?s Scientific Manuscript database

    Tanning of animal hides produces leather, a durable, flexible material that is stabilized against putrefaction. Chrome-tanned wet blue, aldehyde crosslinked wet white, and vegetable tanned hides are major contributors to current leather production. Although the chemistries involved are significant...

  2. 40 CFR 425.25 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Pretreatment standards for existing sources (PSES). 425.25 Section 425.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan...

  3. 40 CFR 425.14 - New source performance standards (NSPS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet...

  4. 40 CFR 425.24 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet...

  5. 40 CFR 425.15 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for existing sources (PSES). 425.15 Section 425.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan...

  6. 40 CFR 425.25 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for existing sources (PSES). 425.25 Section 425.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan...

  7. 40 CFR 425.24 - New source performance standards (NSPS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet...

  8. 40 CFR 425.34 - New source performance standards (NSPS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards (NSPS). 425.34 Section 425.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome...

  9. 40 CFR 425.34 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.34 Section 425.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome...

  10. 40 CFR 425.14 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet...

  11. 40 CFR 425.15 - Pretreatment standards for existing sources (PSES).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Pretreatment standards for existing sources (PSES). 425.15 Section 425.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan...

  12. 40 CFR 425.16 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for new sources (PSNS). 425.16 Section 425.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan...

  13. 40 CFR 425.16 - Pretreatment standards for new sources (PSNS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Pretreatment standards for new sources (PSNS). 425.16 Section 425.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan...

  14. 40 CFR 425.26 - Pretreatment standards for new sources (PSNS)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Pretreatment standards for new sources (PSNS) 425.26 Section 425.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan...

  15. 40 CFR 425.26 - Pretreatment standards for new sources (PSNS)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Pretreatment standards for new sources (PSNS) 425.26 Section 425.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan...

  16. Environmentally Friendly Pretreatment for Department of Defense Applications

    DTIC Science & Technology

    2012-08-29

    Develop an environmentally friendly pretreatment system for multi-material Department of Defense applications ― Free of hexavalent chromium (Cr6...Zn phosphate and chrome wash primer •Two Zirconium pretreatment variations passed the 336 hr and 1000 hr B-117 outlined per MIL-DTL-53022 or MIL

  17. Lessons Learned in Technology Transition (Briefing Charts)

    DTIC Science & Technology

    2011-02-01

    recertification • Environmental regulations • Federal clean air act • OSHA and EPA requirements – Cadmium, hexavalent chromium, VOC reduction • ReaCH Copyright...Efforts • Non-Chromated Exterior System Non-chromated conversion coat and primer • Non- Chrome for other areas • Chemical topcoat reactivation Future

  18. Serpentinite slices within a tectonic zone at the base of the Juvavic nappe system in the Northern Calcareous Alps (Austria): characterization and origin

    NASA Astrophysics Data System (ADS)

    Boehm, Katharina; Schuster, Ralf; Wagreich, Michael; Koller, Friedrich; Wimmer-Frey, Ingeborg

    2014-05-01

    The investigated serpentinites are present in an ENE-WSW orientated tectonic zone at the base of Juvavic nappes (Northern Calcareous Alps), situated at the eastern margin of the Eastern Alps (Lower Austria). They form small tectonically squeezed slices, which are embedded in Permotriassic schists and Middle to Upper Triassic limestones. These serpentinites play an important, but not yet understood role in reconstructing Neotethys evolution, Alpine Orogeny and the correlation of Dinarides and Alps. The largest serpentinite body near to Unterhöflein is 400 to 100 meters in size and was investigated by mineralogical (XRD) and petrological/geochemical (XRF) methods. The primary mineral composition is olivine + orthopyroxene + clinopyroxene + chrome spinel. Pseudomorphs of pyroxenes are visible macroscopically, but almost all primary minerals are replaced by serpentine minerals. Former olivine is converted to chrysotile minerals, which show typical reticulate textures, orthopyroxene turned into lizardite pseudomorphs and chrome spinel is almost completely altered to magnetite. Major contents of chrysotile-α, chrysotile-γ and lizardite and minor antigorite, as well as secondary minerals like talc, chlorite and hydrogrossular were identified with XRD. Results from whole rock geochemistry indicate harzburgitic precursor rocks for the serpentinites. According to the low antigorite content, the rocks have only a weak metamorphic imprint and therefore an obduction rather than a subduction history is likely. This leads to the assumption that these serpentinites possibly originate from the Neotethys and not from the Penninic oceanic realm. Further, the tectonic position of the serpentinite slices is in close vicinity to sediments of the Meliata unit which also occur between Juvavic and underlying Tirolic nappe system (Mandl & Ondrejickova, 1993). Additionally, remnants from ophiolite nappes are found reworked into the surrounding Upper Cretaceous Gosau Group. In the latter also chrome spinel detritus is present. In contrast to the altered chrome spinels in the investigated serpentinites, the spinels from Gosau Group are well preserved and they show similarities to those of Dinaric Cretaceous basins, concerning their harzburgitic and lherzolitic sources (Stern & Wagreich, 2013). If the investigated serpentinites belong to obducted material from Neothetys oceanic realm, a tectonic model of a slab-tearing induced sinistral strike-slip zone could explain the position in the Eastern Alps. However, the relationship to other basic magmatic rocks from several other localities in similar positions, mostly occurring within evaporitic sediments of Permian Haselgebirge (Schorn et al., 2013), has to be clarified.

  19. Ultraviolet (UV)-reflective paint with ultraviolet germicidal irradiation (UVGI) improves decontamination of nosocomial bacteria on hospital room surfaces.

    PubMed

    Jelden, Katelyn C; Gibbs, Shawn G; Smith, Philip W; Hewlett, Angela L; Iwen, Peter C; Schmid, Kendra K; Lowe, John J

    2017-06-01

    An ultraviolet germicidal irradiation (UVGI) generator (the TORCH, ClorDiSys Solutions, Inc.) was used to compare the disinfection of surface coupons (plastic from a bedrail, stainless steel, and chrome-plated light switch cover) in a hospital room with walls coated with ultraviolet (UV)-reflective paint (Lumacept) or standard paint. Each surface coupon was inoculated with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus faecalis (VRE), placed at 6 different sites within a hospital room coated with UV-reflective paint or standard paint, and treated by 10 min UVC exposure (UVC dose of 0-688 mJ/cm 2 between sites with standard paint and 0-553 mJ/cm 2 with UV-reflective paint) in 8 total trials. Aggregated MRSA concentrations on plastic bedrail surface coupons were reduced on average by 3.0 log 10 (1.8 log 10 Geometric Standard Deviation [GSD]) with standard paint and 4.3 log 10 (1.3 log 10 GSD) with UV-reflective paint (p = 0.0005) with no significant reduction differences between paints on stainless steel and chrome. Average VRE concentrations were reduced by ≥4.9 log 10 (<1.2 log 10 GSD) on all surface types with UV-reflective paint and ≤4.1 log 10 (<1.7 log 10 GSD) with standard paint (p < 0.05). At 5 aggregated sites directly exposed to UVC light, MRSA concentrations on average were reduced by 5.2 log 10 (1.4 log 10 GSD) with standard paint and 5.1 log 10 (1.2 log 10 GSD) with UV-reflective paint (p = 0.017) and VRE by 4.4 log 10 (1.4 log 10 GSD) with standard paint and 5.3 log 10 (1.1 log 10 GSD) with UV-reflective paint (p < 0.0001). At one indirectly exposed site on the opposite side of the hospital bed from the UVGI generator, MRSA concentrations on average were reduced by 1.3 log 10 (1.7 log 10 GSD) with standard paint and 4.7 log 10 (1.3 log 10 GSD) with UV-reflective paint (p < 0.0001) and VRE by 1.2 log 10 (1.5 log 10 GSD) with standard paint and 4.6 log 10 (1.1 log 10 GSD) with UV-reflective paint (p < 0.0001). Coating hospital room walls with UV-reflective paint enhanced UVGI disinfection of nosocomial bacteria on various surfaces compared to standard paint, particularly at a surface placement site indirectly exposed to UVC light.

  20. Experimental investigation of a nanofluid absorber employed in a low-profile, concentrated solar thermal collector

    NASA Astrophysics Data System (ADS)

    Li, Qiyuan; Zheng, Cheng; Mesgari, Sara; Hewakuruppu, Yasitha L.; Hjerrild, Natasha; Crisostomo, Felipe; Morrison, Karl; Woffenden, Albert; Rosengarten, Gary; Scott, Jason A.; Taylor, Robert A.

    2015-12-01

    Recent studies [1-3] have demonstrated that nanotechnology, in the form of nanoparticles suspended in water and organic liquids, can be employed to enhance solar collection via direct volumetric absorbers. However, current nanofluid solar collector experimental studies are either relevant to low-temperature flat plate solar collectors (<100 °C) [4] or higher temperature (>100 °C) indoor laboratory-scale concentrating solar collectors [1, 5]. Moreover, many of these studies involve in thermal properties of nanofluid (such as thermal conductivity) enhancement in solar collectors by using conventional selective coated steel/copper tube receivers [6], and no full-scale concentrating collector has been tested at outdoor condition by employing nanofluid absorber [2, 6]. Thus, there is a need of experimental researches to evaluate the exact performance of full-scale concentrating solar collector by employing nanofluids absorber at outdoor condition. As reported previously [7-9], a low profile (<10 cm height) solar thermal concentrating collector was designed and analysed which can potentially supply thermal energy in the 100-250 °C range (an application currently met by gas and electricity). The present study focuses on the design and experimental investigation of a nanofluid absorber employed in this newly designed collector. The nanofluid absorber consists of glass tubes used to contain chemically functionalized multi-walled carbon nanotubes (MWCNTs) dispersed in DI water. MWCNTs (average diameter of 6-13 nm and average length of 2.5-20 μm) were functionalized by potassium persulfate as an oxidant. The nanofluids were prepared with a MCWNT concentration of 50 +/- 0.1 mg/L to form a balance between solar absorption depth and viscosity (e.g. pumping power). Moreover, experimentally comparison of the thermal efficiency between two receivers (a black chrome-coated copper tube versus a MWCNT nanofluid contained within a glass tubetube) is investigated. Thermal experimentation reveals that while the collector efficiency reduced from 73% to 54% when operating temperature increased from ambient to 80 °C by employing a MWCNT nanofluid receiver, the efficiency decreased from 85% to 68% with same operating temperature range by employing black chrome-coated copper tube receiver. This difference can mainly be explained by the reflection optical loss off and higher thermal emission heat loss the front surface of the glass tube, yielding a 90% of transmittance to the MWCNT fluid and a 0.9 emissivity of glass pipe. Overall, an experimental investigation of the performance of a low profile solar collector with a direct volumetric absorber and conventional surface absorber is presented. In order to bring nanotechnology into industrial and commercial heating applications,

  1. 77 FR 26739 - High Pressure Steel Cylinders From the People's Republic of China: Final Determination of Sales...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    .... Department of Transportation, Pipeline and Hazardous Materials Safety Administration (``DOT'') approved high.... International Trading Corporation (``Shanghai J.S.X.''), and Shijiazhuang Enric Gas Equipment Co., Ltd. (``Enric... liquefied gas (``high pressure steel cylinders''). High pressure steel cylinders are fabricated of chrome...

  2. Vulnerability Assessment of Open Source Wireshark and Chrome Browser

    DTIC Science & Technology

    2013-08-01

    UNLIMITED 5 We spent much of the initial time learning about the logical model that modern HTML5 web browsers support, including how users interact with...are supposed to protect users of that site against cross-site scripting) and the new powerful an all-encompassing HTML5 standard. This vulnerability

  3. CERAL 3450 Chrome-Free Aluminum Ceramic Coating

    DTIC Science & Technology

    2008-02-27

    expected and provided good corrosion protection • No service difficulties or warranties related to the coating Rolls Royce T56 • Powers the Lockheed C-130...version of T56 • Inlet air filters typically reduce dust ingestion, but the operating environments can be very corrosive • Borescope photo at ~25,000

  4. RESPONSE OF TALL FESCUE, BUSH BEAN, AND MAIZE TO CHROME TANNERY SLUDGE IN SOILS

    EPA Science Inventory

    Tannery sludge was compared with commercial nitrogen fertiliser to investigate its potential use as an alternative to commercial fertiliser. Soils containing 38% and 7% organic carbon and with nitrogen contents of 1-3% and 0-2%, respectively, were amended with either commercial N...

  5. LETTUCE AND BROCCOLI RESPONSE AND SOIL PROPERTIES RESULTING FROM TANNERY WASTE APPLICATIONS

    EPA Science Inventory

    Broccoli (Brassica oleracea L. var. italica) and lettuce (Lactuca sativa L.) were grown on Willamette sil (Pachic Ultic Argixerolls) amended 1 and 2 yr earlier with chrome tannery wastes at rates up to 192 Mg ha to determine nutrient and trace element availability. Soils were sam...

  6. A novel approach to estimating potential maximum heavy metal exposure to ship recycling yard workers in Alang, India.

    PubMed

    Deshpande, Paritosh C; Tilwankar, Atit K; Asolekar, Shyam R

    2012-11-01

    The 180 ship recycling yards located on Alang-Sosiya beach in the State of Gujarat on the west coast of India is the world's largest cluster engaged in dismantling. Yearly 350 ships have been dismantled (avg. 10,000 ton steel/ship) with the involvement of about 60,000 workers. Cutting and scrapping of plates or scraping of painted metal surfaces happens to be the commonly performed operation during ship breaking. The pollutants released from a typical plate-cutting operation can potentially either affect workers directly by contaminating the breathing zone (air pollution) or can potentially add pollution load into the intertidal zone and contaminate sediments when pollutants get emitted in the secondary working zone and gets subjected to tidal forces. There was a two-pronged purpose behind the mathematical modeling exercise performed in this study. First, to estimate the zone of influence up to which the effect of plume would extend. Second, to estimate the cumulative maximum concentration of heavy metals that can potentially occur in ambient atmosphere of a given yard. The cumulative maximum heavy metal concentration was predicted by the model to be between 113 μg/Nm(3) and 428 μg/Nm(3) (at 4m/s and 1m/s near-ground wind speeds, respectively). For example, centerline concentrations of lead (Pb) in the yard could be placed between 8 and 30 μg/Nm(3). These estimates are much higher than the Indian National Ambient Air Quality Standards (NAAQS) for Pb (0.5 μg/Nm(3)). This research has already become the critical science and technology inputs for formulation of policies for eco-friendly dismantling of ships, formulation of ideal procedure and corresponding health, safety, and environment provisions. The insights obtained from this research are also being used in developing appropriate technologies for minimizing exposure to workers and minimizing possibilities of causing heavy metal pollution in the intertidal zone of ship recycling yards in India. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. 78 FR 60876 - Advisory Committee to the Director (ACD), Centers for Disease Control and Prevention (CDC)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Advisory... by teleconference. Please dial (877) 930-8819 and enter code 1579739. Web links: Windows Connection-2: http://wm.onlinevideoservice.com/CDC2 Flash Connection-4 (For Safari and Google Chrome Users): http...

  8. 78 FR 60876 - Advisory Committee to the Director (ACD), Centers for Disease Control and Prevention (CDC)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Advisory... by teleconference. Please dial (877) 930-8819 and enter code 1579739. Web Links Windows Connection-2: http://wm.onlinevideoservice.com/CDC2 . Flash Connection-4 (For Safari and Google Chrome Users): http...

  9. SITE CHARACTERIZATION OF A CHROMIUM SOURCE AREA AT THE USCG SUPPORT CENTER, ELIZABETH CITY, NC

    EPA Science Inventory

    The chrome source area is located beneath an old electroplating shop at the United States Coast Guard Support Center near Elizabeth City, NC . This electroplating shop was in
    use for approximately 30 years until 1984 and was the source of discharges of chromic and sulfuric...

  10. 77 FR 25647 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-01

    ... inspections of the outer diameter chrome on the center axles of the MLG for cracks; and related investigative... MLG for cracks; and related investigative and corrective actions if necessary. The related... operators Lubrication of MLG pivot joints.. 4 work-hours x $85 $0 $340 per $54,400 per per hour = $340...

  11. Using Web Speech Technology with Language Learning Applications

    ERIC Educational Resources Information Center

    Daniels, Paul

    2015-01-01

    In this article, the author presents the history of human-to-computer interaction based upon the design of sophisticated computerized speech recognition algorithms. Advancements such as the arrival of cloud-based computing and software like Google's Web Speech API allows anyone with an Internet connection and Chrome browser to take advantage of…

  12. Voice-Recognition Augmented Performance Tools in Performance Poetry Pedagogy

    ERIC Educational Resources Information Center

    Devanny, David; McGowan, Jack

    2016-01-01

    This provocation shares findings from the use of bespoke voice-recognition performance software in a number of seminars (which took place in the 2014-2016 academic years at Glasgow School of Art, University of Warwick, and Falmouth University). The software, made available through this publication, is a web-app which uses Google Chrome's native…

  13. DoD Metal Finishing Workshop: Chromate Alternatives for Metal Treatment and Sealing

    DTIC Science & Technology

    2007-05-17

    always) contain Co inhibitors and nanophase SiO2 to fill scratches. For many materials trivalent processes are now as good as (and in some cases better...6 2.4. Trivalent and non-chrome technology ..................................................... 6 3...5 Figure 3. Trivalent passivate market (1000 gals).................................................. 6 Figure 4. Protection

  14. 77 FR 3281 - High Pressure Steel Cylinders From China; Scheduling of the Final Phase of Countervailing Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ...)] High Pressure Steel Cylinders From China; Scheduling of the Final Phase of Countervailing Duty and... retarded, by reason of subsidized and less-than-fair-value imports from China of high pressure steel... (``high pressure steel cylinders''). High pressure steel cylinders are fabricated of chrome alloy steel...

  15. COMPARISON OF RAPID METHODS TO EVALUATE CHLORINE INACTIVATION OF THE BIOLOGICAL AGENT E. COLI 0157:H7

    EPA Science Inventory

    Rapid viability tests of the Catagory B agent Escherichia coli O157:H7 were evaluated after disinfection with chlorine. The metabolic activity dyes ChemChrome V6, a modified fluorescein diacetate (FDA) and 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) were compared to standard ...

  16. Introduction to Toxicity and Risk Assessment for Project Chemists

    DTIC Science & Technology

    2012-03-27

    Toxicity of Hexavalent Chromium  External review complete  EPA will wait until studies underway on carcinogenic mode of action are complete to...finalize the assessment  NJ and Cal values for hex chrome 16 Risk-Based Screening Levels Resident Soil (mg/kg) Resident Water Use (µg/L) DRAFT 0.04

  17. Optical properties and crystallinity of silver mirrors under a 35 krad cobalt-60 radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiu, Po-Kai, E-mail: pkchiu@itrc.narl.org.tw; Chiang, Donyau; Lee, Chao-Te

    2015-09-15

    This study addresses the effects of thin film optical design and environmental radiation on the optical properties of silver mirrors. Different experimental thin film optical designs are selected, and the film stack is built using Macleod's approach. Mirror elements are exposed to the same dose of radiation and their properties are characterized using a spectrophotometer equipped with an integration sphere and an x-ray diffractometer. Spectrophotometric analyses of mirrors exposed to about 35 krad of {sup 60}Co radiations overall show that the B270 glass substrates coated with titanium oxide (TiO{sub 2}), silicon dioxide (SiO{sub 2}), pure chrome, and pure silver effectivelymore » reduces radiation damage. The absorption spectrum of the TiO{sub 2} film in the visible region decreases after radiation and displays drifting. As thin metal films comparison, the silver thin film exhibits higher radiation resistance than the chrome thin film. The x-ray diffraction analysis on metal film layers reveals that crystallinity slightly increases when the silver thin film is irradiated.« less

  18. Bioremoval of trivalent chromium using Bacillus biofilms through continuous flow reactor.

    PubMed

    Sundar, K; Sadiq, I Mohammed; Mukherjee, Amitava; Chandrasekaran, N

    2011-11-30

    Present study deals with the applicability of bacterial biofilms for the bioremoval of trivalent chromium from tannery effluents. A continuous flow reactor was designed for the development of biofilms on different substrates like glass beads, pebbles and coarse sand. The parameters for the continuous flow reactor were 20 ml/min flow rate at 30°C, pH4. Biofilm biomass on the substrates was in the following sequence: coarse sand>pebbles>glass beads (4.8 × 10(7), 4.5 × 10(7) and 3.5 × 10(5)CFU/cm(2)), which was confirmed by CLSM. Biofilms developed using consortium of Bacillus subtilis and Bacillus cereus on coarse sand had more surface area and was able to remove 98% of Cr(III), SEM-EDX proved 92.60% Cr(III) adsorption on biofilms supported by coarse sand. Utilization of Bacillus biofilms for effective bioremoval of Cr(III) from chrome tanning effluent could be a better option for tannery industry, especially during post chrome tanning operation. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. A review on management of chrome-tanned leather shavings: a holistic paradigm to combat the environmental issues.

    PubMed

    Pati, Anupama; Chaudhary, Rubina; Subramani, Saravanabhavan

    2014-10-01

    Raw hide/skins come to the tanners as a by-product of meat industry which is converted into value-added leather as product for fashion market. Leather manufacturing is a chemical process of natural biological matrix. It employs a huge quantity of water and inorganic and organic chemicals for processing and thereby discharges solid and liquid wastes into the environment. One of the potential solid wastes generated from leather industry is chrome-tanned leather shavings (CTLSs), and its disposal is increasingly becoming a huge challenge on disposal to tanners due to presence of heavy metal chromium. Hence, finding a sustainable solution to the CTLS disposal problem is a prime challenge for global tanners and researchers. This paper aims to the deeper review of various disposal methods on CTLS such as protein, chromium, and energy recovery processes and its utilization methodologies. Sustainable technologies have been developed to overcome CTLS solid wastes emanating from leather processing operations. Further, this review paper brings a broader classification of developed methodologies for treatment of CTLSs.

  20. Waterborne carboxyl-terminated hyperbranched oligomer polyester ligand: Synthesis, characterization and chelation with chromium(III)

    NASA Astrophysics Data System (ADS)

    Yao, Qi; Li, Chenying; Huang, Henghui; Chen, Hualin; Liu, Bailing

    2017-09-01

    A series of carboxyl-terminated hyperbranched oligomer polyester (HBP) with different degree of branching (DB) and number average molar mass (Mbarn) have been prepared. The molecular structure, degree of branching, molecular mass and its distribution of HBP were investigated by FTIR, 1H NMR, and GPC, respectively. And the coordination number, stability constant and degree of dissociation (α) between HBP and chromium(Ⅲ) were measured via continuous variation method (Job's plot). Experimental results show that the coordination capability between HBP and chromium(Ⅲ) affected by both DB and molecular mass, and the latter plays a decisive role. Moreover HBP outperforms low molecular weight of organic acids (citric acid, acetic acid) and linear polyacrylic acid with similar molecular mass. The coordination number and stability constants of HBP-3 (Mbarn = 1713 Da, Mbarw /Mbarn (PDI) = 1.11 and DB = 0.72) can reach 4 and 6.55e+008, which demonstrated it can be selected as a good ligand to coordination with chromium(Ⅲ). Therefore HBP can be used as chrome auxiliary in chrome tanning to improve the absorption of chromium.

  1. Useful surface parameters for biomaterial discrimination.

    PubMed

    Etxeberria, Marina; Escuin, Tomas; Vinas, Miquel; Ascaso, Carlos

    2015-01-01

    Topographical features of biomaterials' surfaces are determinant when addressing their application site. Unfortunately up to date there has not been an agreement regarding which surface parameters are more representative in discriminating between materials. Discs (n = 16) of different currently used materials for implant prostheses fabrication, such as cast cobalt-chrome, direct laser metal soldered (DLMS) cobalt-chrome, titanium grade V, zirconia (Y-TZP), E-glass fiber-reinforced composite and polyetheretherketone (PEEK) were manufactured. Nanoscale topographical surface roughness parameters generated by atomic force microscopy (AFM), microscale surface roughness parameters obtained by white light interferometry (WLI) and water angle values obtained by the sessile-water-drop method were analyzed in order to assess which parameter provides the best optimum surface characterization method. Correlations between nanoroughness, microroughness, and hydrophobicity data were performed to achieve the best parameters giving the highest discriminatory power. A subset of six parameters for surface characterization were proposed. AFM and WLI techniques gave complementary information. Wettability did not correlate with any of the nanoroughness parameters while it however showed a weak correlation with microroughness parameters. © Wiley Periodicals, Inc.

  2. Stability Analysis of Plates and Shells

    NASA Technical Reports Server (NTRS)

    Knight, Norman F., Jr. (Compiler); Nemeth, Michael P. (Compiler)

    1998-01-01

    This special publication contains the papers presented at the special sessions honoring Dr. Manuel Stein during the 38th AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics, and Materials Conference held in Kissimmee, Florida, Apdl 7-10, 1997. This volume, and the SDM special sessions, are dedicated to the memory of Dr. Manuel Stein, a major pioneer in structural mechanics, plate and shell buckling, and composite structures. Many of the papers presented are the work of Manny's colleagues and co-workers and are a result, directly or indirectly, of his influence. Dr. Stein earned his Ph.D. in Engineering Mechanics from Virginia Polytechnic Institute and State University in 1958. He worked in the Structural Mechanics Branch at the NASA Langley Research Center from 1943 until 1989. Following his retirement, Dr. Stein continued his involvement with NASA as a Distinguished Research Associate.

  3. Does the Type of Metal Instrumentation Affect the Risk of Surgical Site Infection in Pediatric Scoliosis Surgery?

    PubMed

    Wright, Margaret L; Skaggs, David L; Matsumoto, Hiroko; Woon, Regina P; Trocle, Ashley; Flynn, John M; Vitale, Michael G

    2016-05-01

    Retrospective cohort study. To determine the association of implant metal composition with the risk of surgical site infection (SSI) following pediatric spine surgery. SSI is a well-described complication following pediatric spine surgery. Many risk factors have been identified in the literature, but controversy remains regarding metal composition as a risk factor. This was a retrospective study of patients who underwent posterior spinal instrumentation procedures between January 1, 2006, and December 31, 2008, at three large children's hospitals for any etiology of scoliosis and had at least 1 year of postoperative follow-up. Procedures included posterior spinal fusion, growth-friendly instrumentation, and revision of spinal instrumentation. The Centers for Disease Control and Prevention definition of SSI was used. A chi-squared test was performed to determine the relationship between type of metal instrumentation and development of an SSI. The study included 874 patients who underwent 1,156 total procedures. Overall, 752 (65%) procedures used stainless steel instrumentation, 238 (21%) procedures used titanium instrumentation, and the remaining 166 (14%) procedures used cobalt chrome and titanium hybrid instrumentation. The overall risk of infection was 6.1% (70/1,156) per procedure, with 5.9% (44/752) for stainless steel, 6.7% (12/238) for titanium, and 6.0% (10/166) for cobalt chrome. The multiple regression analysis found no significant differences in the metal type used between patients with and without infection (p = .886) adjusting for etiology, instrumentation to pelvis, and type of procedures. When stratified based on etiology, the multiple regression analyses also found no significant difference in SSI between two metal type groups. This study found no difference in risk of infection with stainless steel, titanium, or cobalt chrome/titanium instrumentation and is adequately powered to detect a true difference in risk of SSI. Level II, prognostic. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  4. Degradation process of lead chromate in paintings by Vincent van Gogh studied by means of synchrotron X-ray spectromicroscopy and related methods. 1. Artificially aged model samples.

    PubMed

    Monico, Letizia; Van der Snickt, Geert; Janssens, Koen; De Nolf, Wout; Miliani, Costanza; Verbeeck, Johan; Tian, He; Tan, Haiyan; Dik, Joris; Radepont, Marie; Cotte, Marine

    2011-02-15

    On several paintings by artists of the end of the 19th century and the beginning of the 20th Century a darkening of the original yellow areas, painted with the chrome yellow pigment (PbCrO(4), PbCrO(4)·xPbSO(4), or PbCrO(4)·xPbO) is observed. The most famous of these are the various Sunflowers paintings Vincent van Gogh made during his career. In the first part of this work, we attempt to elucidate the degradation process of chrome yellow by studying artificially aged model samples. In view of the very thin (1-3 μm) alteration layers that are formed, high lateral resolution spectroscopic methods such as microscopic X-ray absorption near edge (μ-XANES), X-ray fluorescence spectrometry (μ-XRF), and electron energy loss spectrometry (EELS) were employed. Some of these use synchrotron radiation (SR). Additionally, microscopic SR X-ray diffraction (SR μ-XRD), μ-Raman, and mid-FTIR spectroscopy were employed to completely characterize the samples. The formation of Cr(III) compounds at the surface of the chrome yellow paint layers is particularly observed in one aged model sample taken from a historic paint tube (ca. 1914). About two-thirds of the chromium that is present at the surface has reduced from the hexavalent to the trivalent state. The EELS and μ-XANES spectra are consistent with the presence of Cr(2)O(3)·2H(2)O (viridian). Moreover, as demonstrated by μ-XANES, the presence of another Cr(III) compound, such as either Cr(2)(SO(4))(3)·H(2)O or (CH(3)CO(2))(7)Cr(3)(OH)(2) [chromium(III) acetate hydroxide], is likely.

  5. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

    PubMed

    Vavrík, P; Landor, I; Denk, F

    2008-12-01

    The study evaluates mid-term results of total knee replacement with a zirconia ceramic (ZrO2) femoral component. The evaluated group comprised 20 knees in 19 patients (4 men and 15 women). In one patient the replacement was performed bilaterally. Two patients had in the contralateral knee the same type of prosthesis with a femoral chrome-cobalt component.The mean age at the time of operation was 65.2 years (range, 38-81 years).The primary indication was 14 times osteoarthritis and 5 times rheumatoid arthritis. The average follow-up period was 6.5 years (range, 2.1-8.5 years). Patients included in the study regardless of age, body mass and the basic diagnosis, agreed with the use of the ceramic femoral component. The evaluation covered a range of motion, mechanical axis, joint stability, pain, swelling, ability to walk on level ground and on stairs, subjective satisfaction (EULAR Knee Chart). Radiograph were assessed at one year intervals in two projections to identify the incidence of radiolucency around the implant. The Kaplan-Meier survival curve was used and compared with the survival curve in identical chrome-cobalt implants. At he final follow-up, 14 knees were evaluated, because 3 patients died without any connection with the implant, in one case the tibial component migrated due to necrosis of the tibial condyle in a patient with RA and two implants had to be revised and replaced due to polyethylene wear. No infection or negative tissue reaction was recorded in the evaluated group. The average flexion range was 109 degrees. All knees were stable and without swelling, in two cases there occurred slight femoropatellar pain. Twelve patients were fully satisfied, 2 patients were satisfied with a certain reservation. The differences in the course of the survival curves of chrome-cobalt and ceramic implants were statistically insignificant. Although the use of zirconia ceramics in vitro reduces the amount of polyethylene wear, the clinical outcomes of total knee replacements as compared to the hip are not convincing. One of the causes may be the substantially different and more complex biomechanics of the knee. Tribology improvement of the femoral ceramic component cannot compensate the deficiencies in the joint balancing in flexion and extension. The economically and technologically demanding production of these implants may be justified in patients with allergies caused by chrome-cobalt components. The results of mid-term follow-up of the use of zirconia ceramic femoral components proved no impact on the improvement of the period of survival of the knee implant. No adverse response to the material or mechanical failure of the ceramic components was encountered. Key words: total knee replacement, zirconia ceramic femoral component, TKR mid-term results, ceramic knee survival curve.

  6. Removal of cationic pollutants from water by xanthated corn cob: optimization, kinetics, thermodynamics, and prediction of purification process.

    PubMed

    Kostić, Miloš; Đorđević, Miloš; Mitrović, Jelena; Velinov, Nena; Bojić, Danijela; Antonijević, Milan; Bojić, Aleksandar

    2017-07-01

    The removal of Cr(III) ions and methylene blue (MB) from aqueous solutions by xanthated corn cob (xCC) in batch conditions was investigated. The sorption capacity of xCC strongly depended of the pH, and increase when the pH rises. The kinetics was well fitted by pseudo-second-order and Chrastil's model. Sorption of Cr(III) ions and MB on xCC was rapid during the first 20 min of contact time and, thereafter, the biosorption rate decrease gradually until reaching equilibrium. The maximum sorption capacity of 17.13 and 83.89 mg g -1 for Cr(III) ions and MB, respectively, was obtained at 40 °C, pH 5, and sorbent dose 4 g dm -3 for removal of Cr(III) ions and 1 g dm -3 for removal of MB. The prediction of purification process was successfully carried out, and the verification of theoretically calculated amounts of sorbent was confirmed by using packed-bed column laboratory system with recirculation of the aqueous phase. The wastewater from chrome plating industry was successfully purified, i.e., after 40 min concentration of Cr(III) ions was decreased lower than 0.1 mg dm -3 . Also, removal of MB from the river water was successfully carried out and after 40 min, removal efficiency was about 94%.

  7. Topography reconstruction of specular surfaces

    NASA Astrophysics Data System (ADS)

    Kammel, Soren; Horbach, Jan

    2005-01-01

    Specular surfaces are used in a wide variety of industrial and consumer products like varnished or chrome plated parts of car bodies, dies, molds or optical components. Shape deviations of these products usually reduce their quality regarding visual appearance and/or technical performance. One reliable method to inspect such surfaces is deflectometry. It can be employed to obtain highly accurate values representing the local curvature of the surfaces. In a deflectometric measuring system, a series of illumination patterns is reflected at the specular surface and is observed by a camera. The distortions of the patterns in the acquired images contain information about the shape of the surface. This information is suited for the detection and measurement of surface defects like bumps, dents and waviness with depths in the range of a few microns. However, without additional information about the distances between the camera and each observed surface point, a shape reconstruction is only possible in some special cases. Therefore, the reconstruction approach described in this paper uses data observed from at least two different camera positions. The data obtained is used separately to estimate the local surface curvature for each camera position. From the curvature values, the epipolar geometry for the different camera positions is recovered. Matching the curvature values along the epipolar lines yields an estimate of the 3d position of the corresponding surface points. With this additional information, the deflectometric gradient data can be integrated to represent the surface topography.

  8. Chromium VI and stomach cancer: a meta-analysis of the current epidemiological evidence.

    PubMed

    Welling, Roberta; Beaumont, James J; Petersen, Scott J; Alexeeff, George V; Steinmaus, Craig

    2015-02-01

    Chromium VI (hexavalent chromium, Cr(VI)) is an established cause of lung cancer, but its association with gastrointestinal cancer is less clear. The goal of this study was to examine whether the current human epidemiological research on occupationally inhaled Cr(VI) supports the hypothesis that Cr(VI) is associated with human stomach cancer. Following a thorough literature search and review of individual studies, we used meta-analysis to summarise the current epidemiological literature on inhaled Cr(VI) and stomach cancer, explore major sources of heterogeneity, and assess other elements of causal inference. We identified 56 cohort and case-control studies and 74 individual relative risk (RR) estimates on stomach cancer and Cr(VI) exposure or work in an occupation associated with high Cr(VI) exposure including chromium production, chrome plating, leather work and work with Portland cement. The summary RR for all studies combined was 1.27 (95% CI 1.18 to 1.38). In analyses limited to only those studies identifying increased risks of lung cancer, the summary RR for stomach cancer was higher (RR=1.41, 95% CI 1.18 to 1.69). Overall, these results suggest that Cr(VI) is a stomach carcinogen in humans, which is consistent with the tumour results reported in rodent studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. nStudy: A System for Researching Information Problem Solving

    ERIC Educational Resources Information Center

    Winne, Philip H.; Nesbit, John C.; Popowich, Fred

    2017-01-01

    A bottleneck in gathering big data about learning is instrumentation designed to record data about processes students use to learn and information on which those processes operate. The software system nStudy fills this gap. nStudy is an extension to the Chrome web browser plus a server side database for logged trace data plus peripheral modules…

  10. Environmentally Friendly Zirconium Oxide Pretreatment

    DTIC Science & Technology

    2013-05-01

    during the conversion of the highly soluble hexavalent chromate ions to an inert and relatively insoluble trivalent chromium oxide layer. Depletion of...are being used commercially in automotive and other industrial operations as replacements to hexavalent chromium -based and zinc phosphate...Society for Testing and Materials AVCRAD Aviation Classification Repair Activity Depot Chrome (VI) Hexavalent Chromium CRS Cold Rolled Steel

  11. 78 FR 24426 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-25

    ... application for the Kineflex/C Cervical Artificial Disc sponsored by SpinalMotion. The Kineflex/C is a metal-on-metal (cobalt chrome molybdenum alloy) cervical total disc replacement device. The Kineflex/C is... degenerative disc disease (DDD) where DDD is defined as discogenic back pain with degeneration of the disc as...

  12. Electrodeposited Nano Co-P: Coating Development and Technology Insertion at NADEP-JAX

    DTIC Science & Technology

    2008-02-27

    Properties nCoP Hard Chrome Hardness 530-580 VHN 800-1200 VHN Ductility Elongation 2-7% < 1% Abrasive Wear (Taber) CS-17 wheels 17-20 mg/1000 cycles 3 mg...gage) - Due to high stress concentration (no runout ) Prior fatigue data invalid – testing to be repeated Gage Failure Transition region failure SERDP

  13. Eco-friendly rubberized cotton fabric roller for ginning machines.

    PubMed

    Iyer, G V

    2007-01-01

    This article discusses the pollution caused by chrome composite leather-clad (CCLC) rollers commonly used in cotton roller ginning mills and suggests an alternative roller material. CCLC rollers contain about 18,000 to 36,000 mg/kg (ppm) total chromium in trivalent and hexavalent forms, which are toxic to human health and carcinogenic. When seed-cotton is processed in double roller (DR) ginning machines, the lint is contaminated with chromium, and chromium particles are carried into the spun yarns and cotton by-products. Specifically, due to persistent rubbing of the leather-clad roller over the stationary knife during the ginning process, the lint is contaminated with about 140 to 1990 ppm of chromium, and the spun yarns and cotton by-products contain about 100 to 200 ppm, far in excess of the standard limit of 0.1 ppm. Gin and mill workers are directly exposed to this carcinogenic substance. To offset this problem, pollution-free rubberized cotton fabric (RCF) rollers have been fabricated and tested in roller gins. The RCF roller covering is made of multiple layers of fabric bonded together using a white rubber compound, which has a surface finish conducive to high ginning efficiency. This eliminates chromium contamination and pollution during the ginning process. On the basis of the design and development of various test rollers and subsequent evaluation studies, the performance of pollution-free RCF rollers has been demonstrated with reference to their commercial benefit and eco-friendliness in cotton ginning mills.

  14. Pigment Synthesis for the Exploration of Binding Media Using a Lead-Free Alternative to Chrome Yellow

    ERIC Educational Resources Information Center

    Gaquere-Parker, Anne C.; Hill, Patricia S.; Haaf, Michael P.; Parker, Cass D.; Doles, N. Allie; Yi, Amanda K.; Kaminski, Todd A.

    2017-01-01

    Generating enthusiasm among nonscience majors in a laboratory course is a difficult task. Often, students are asked to perform a precipitation reaction, only to collect and then safely dispose of the solid without detailing composition, properties, or uses. In an effort to keep the students engaged, this laboratory exercise presents an innovative…

  15. Evaluation of Microcomposite Coatings for Chrome Replacement

    DTIC Science & Technology

    2009-09-02

    Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time...of information . Send comments regarding this burden estimate or any other aspect of this collection of information , including suggestions for reducing...this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204

  16. Hexavalent Chromium Free Coatings Projects for Aerospace Applications

    DTIC Science & Technology

    2012-08-01

    1-Evaluate trivalent chromium pretreatment (TCP) for use on aluminum  2-Evaluate three hexavalent chrome free alternatives to DoD-P-15328 wash...UNCLASSIFIED UNCLASSIFIED Hexavalent Chromium Free Coatings Projects for Aerospace Applications Report Documentation Page Form...COVERED 00-00-2012 to 00-00-2012 4. TITLE AND SUBTITLE Hexavalent Chromium Free Coatings Projects for Aerospace Applications 5a. CONTRACT NUMBER

  17. Affinities of the Boletus chromapes group to Royoungia and the description of two new genera, Harrya and Australopilus

    Treesearch

    Roy E. Halling; Mitchell Nuhn; Todd Osmundson; Nigel Fechner; James M. Trappe; Kasem Soytong; David Arora; David S. Hibbett; Manfred Binder

    2012-01-01

    Harrya is described as a new genus of Boletaceae to accommodate Boletus chromapes, a pink-capped bolete with a finely scabrous stipe adorned with pink scabers, a chrome yellow base and a reddish-brown spore deposit. Harrya is a unique generic lineage with two species, one of which is newly described (

  18. "A Chrome Yellow Blackboard with Blue Chalk": New Education and the New Architecture--Modernism at Koornong School

    ERIC Educational Resources Information Center

    Goad, Philip

    2010-01-01

    This paper examines, through one school's location in Australia, the international reach and nature of the networks associated with New Education; the aims and ideals of Clive and Janet Nield, the main protagonists behind the venture of Koornong School; what transformations they brought to progressive education; and the deliberate assembling of a…

  19. Supplier Perspective: Paints & Finishes for Corrosion Protection of Military Vehicles

    DTIC Science & Technology

    2010-06-15

    Systems , Oshkosh Truck, General Dynamics, AM General. Automotive approvals include Honda , Toyota , General Motors, Ford, Chrysler, BMW, Subaru, Nissan...Military Compliance EXAMPLE OF AN INFERIOR PROCESS MIL-DTL-5541 Aluminum pretreatment conveyor system using a trivalent chrome pretreatment...Automotive has become a leader in corrosion prevention. Vehicles last much longer due to improved paint systems . Much of this is attributed to

  20. Lexicon Sextant: Modeling a Mnemonic System for Customizable Browser Information Organization and Management

    ERIC Educational Resources Information Center

    Shen, Siu-Tsen

    2016-01-01

    This paper presents an ongoing study of the development of a customizable web browser information organization and management system, which the author has named Lexicon Sextant (LS). LS is a user friendly, graphical web based add-on to the latest generation of web browsers, such as Google Chrome, making it easier and more intuitive to store and…

  1. Acquisition Environment, Safety, and Occupational Health: Lessons Learned From DoD Acquisition Systems Engineering Program Support Reviews

    DTIC Science & Technology

    2011-05-01

    not integrated Lack of emphasis on implementing ESOH mitigations Failure to address USD (AT&L) hexavalent chrome policy 12 ODUSD(I&E) / CMRM Value of...4.1, Design Considerations Factor 4.1.4, ESOH Factor 4.1.7, Corrosion ( Hexavalent Chromium) 6 ODUSD(I&E) / CMRM 1. Mission Capabilities – Clarity and

  2. Managing Chemical & Material Risks

    DTIC Science & Technology

    2011-12-01

    Certification Program Acquisition, Technology and Logistics 9 DoD Hexavalent Chromium Risk Reduction Non- Chrome Primer II EXAVAJ ENT CHROM lrUMI...Royal Demolition eXplosive (RDX) • Cyclotrimethylenetrinitramine  Hexavalent Chromium (Cr6+) Naphthalene …pending downgrade to watch list Beryllium...T1me (secondo) 700 Acquisition, Technology and Logistics 10 Hexavalent Chromium Risk Management Actions • DoD minimization policy signed April

  3. NAVAIR Progress in Assessing, Validating and Implementing Non-Chromate Primers (Briefing charts)

    DTIC Science & Technology

    2011-02-09

    logistics for any new coating or coating system NAVAIR Application Areas for Hexavalent Chromium Alternatives: Status Components/ Structure... Hexavalent chromium alternatives Sacrificial Coating Post Treatment MIL-A-8625 Anodize Avionics/ Electronics Magnesium/Titanium Conversion Aluminum Anodizing...Aluminum Pretreatment Type IC Seal Type IIB Seal Type II Seal Phosphating Rinse (Aluminum)Rinse (Steel) Cadmium Zinc-Nickel Aluminum Bonding Chrome

  4. Biosorption of trivalent chromium by free and immobilized blue green algae: kinetics and equilibrium studies.

    PubMed

    Shashirekha, V; Sridharan, M R; Swamy, Mahadeswara

    2008-03-01

    The process of biosorption of trivalent chromium (Cr(3+)) by live culture of Spirulina platensis and the sorption potential by the dried biomass, in both free and immobilized states have been investigated for a simulated chrome liquor in the concentration range of 100-4500 ppm. Both live and dried biomass were very good biosorbents as they could remove high amounts of chromium from tannery wastewater. Polyurethane foam and sodium alginate were used as immobilizing agents and their performances compared. Biosorption kinetic data on Cr(3+) sorption onto dried biomass were analyzed using pseudo-first-and pseudo-second-order kinetic models in batch column experiments. The second-order equation was more appropriate to predict the rate of biosorption. Subsequently, the effects of height of packing & diameter of the column, concentration of blue-green algae (BGA) in varying amounts of sodium alginate, chromium concentration were studied. The results fit into both Langmuir & Freundlich isotherm models with very high regression coefficients. Furthermore, equilibrium studies using retan chrome liquor (RCL), with a chromium concentration of 1660 ppm, obtained from a tannery also showed promising results. In general, our studies indicate the efficacy of the algal species in removal of chromium from tannery wastewater.

  5. Implant Failure After Motec Wrist Joint Prosthesis Due to Failure of Ball and Socket-Type Articulation-Two Patients With Adverse Reaction to Metal Debris and Polyether Ether Ketone.

    PubMed

    Karjalainen, Teemu; Pamilo, Konsta; Reito, Aleksi

    2018-04-21

    We describe 2 cases of articulation-related failures resulting in revision surgery after a Motec total wrist arthroplasty: one with an adverse reaction to metal debris and the other with an adverse reaction to polyether ether ketone. In the first patient, blood cobalt and chrome levels were elevated and magnetic resonance imaging showed clear signs of a pseudotumor. The other patient had an extensive release of polyether ether ketone particles into the surrounding synovia due to adverse wear conditions in the cup, leading to the formation of a fluid-filled cyst sac with a black lining and diffuse lymphocyte-dominated inflammation in the synovia. We recommend regular follow-up including x-rays, monitoring of cobalt and chrome ion levels, and a low threshold for cross-sectional imaging in patients who have undergone total wrist arthroplasty with a Motec joint prosthesis. Wear-related problems can also develop in implants in which polyether ether ketone is the bulk material. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. A new critical dimension metrology for chrome-on-glass substrates based on s-parameter measurements extracted from coplanar waveguide test structures

    NASA Astrophysics Data System (ADS)

    Nwokoye, Chidubem A.; Zaghloul, Mona; Cresswell, Michael W.; Allen, Richard A.; Murabito, Christine E.

    2006-10-01

    The technical objective of the work reported here is to assess whether radio-frequency (RF) measurements made on coplanar waveguide (CPW) test structures, which are replicated in conducting material on insulating substrates, could be employed to extract the critical dimension (CD) of the signal line using its center-to-center separation from the groundlines as a reference. The specific near-term objective is to assess whether this CPW-based CD-metrology has sensitivity and repeatability competitive with the other metrology techniques that are now used for chrome-on-glass (COG) photomasks. An affirmative answer is encouraging because advancing to a non-contact and non-vacuum implementation would then seem possible for this application. Our modeling of specific cases shows that, when the pitch of the replicated lines of the CPW is maintained constant, the sensitivity of its characteristic impedance to the CDs of the signal and ground lines is approximately 60 Ω/μm. This is a potentially useful result. For the same implementation, the quantity ∂C/∂w has a value of approximately 45 (pF/m)/μm, which appears to be large enough to provide acceptable accuracy.

  7. Thermal behaviour of chrome shavings and of sludges recovered after digestion of tanned solid wastes with calcium hydroxide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tahiri, S.; Albizane, A.; Messaoudi, A.

    2007-07-01

    The thermal behaviour of chrome shavings and of sludges recovered after digestion of tanned wastes with Ca(OH){sub 2} was studied. Ashes obtained after incineration of wastes at various temperatures were analysed by X-ray diffraction and EDX method. The main crystallized phases present in the ash obtained at 600 deg. C are Cr{sub 2}O{sub 3} and NaCl. The diffractograms revealed an increase in the intensities of the chromium oxide peaks and a very notable decrease of the amount of sodium chloride at 1100 deg. C. EDX analysis revealed a total disappearance of the chlorine peak at this temperature. Scanning electron micrographsmore » show that the waste lost its fibrous aspect when the temperature increases. Formation of aggregates was noted after 550 deg. C. Combustion of organic matters and decarbonation phenomenon are the main stages observed on GTA and DTA curves of sludges. These phenomena are, respectively, exothermic and endothermic. The diffractogram of sludges recorded at 550 deg. C, in the presence of a constant oxygen surplus, revealed the presence of CaCrO{sub 4} and CaCO{sub 3}.« less

  8. Petrology of ultramafic xenoliths from Loihi Seamount, Hawaii

    USGS Publications Warehouse

    Clague, D.A.

    1988-01-01

    Ultramafic xenoliths were recovered in four alkalic lava flows from Loihi Seamount at depths between 2200 and 1400 m. No xenolith bearing flows were sampled near the summit despite a concentrated dredge program. The flows, three of alkalic basalt and one of basanite, contain common olivine megacrysts and small xenoliths of dunite, rarer harzburgite, and a single wehrlite. Olivine megacrysts as large as 8 mm are Fo84-88.6 and contain magnesiochromite inclusions with 1.1-3.5 wt.% TiO2. Dunite contains Fo83.5-88.5 olivine, meganesiochromite with 1.5-6.9 wt.% TiO2 (avg. 3.2 wt.), and extremely rare chrome-rich diopside. The wehrlite contains euhedral Fo85.9 olivine and magnesiochromite with 1.9-4.7 wt.% TiO2, poikilitically enclosed in chrome-rich diposide (Wo45.4En48.0s6.6). Most of the olivine megacrysts, dunite, and the wehrlite are cumulates of Loihi alkalic lavas that accumulated in a magma storage zone located at least 16 km below sea level. The rarity of dunite related to tholeiitic magmas supports the interpretation that the alkalic lavas at Loihi generally predate the tholeiitic lavas. -from Author

  9. NTIAC Handbook. Revision/Supplement Number 1

    DTIC Science & Technology

    1982-06-01

    Engi- neering, Ceramics Bldg., 22-17, 2-Chrome, Hyakunincho, Shinjiku-ku, Tokyo, Japan NTIAC-023416 4 Yamanouchi, Kazuhiko; Sachse, Wolfgang "Shear...tional Bureau of Standards, Washington, DC 20234 NTIAC-022425M Sachse, Wolfgang ; Pao, Yih-Hsing "Ultrasonic Nondestructive Testing of Materials...burg, MD, NBS SP 596, 395-406; National Bureau of Standards, Washington, DC 29234 Pao, Yih-Hsing; Sachse, Wolfgang "Ultrasonic Nondestructive Testing of

  10. High Temperature Hot Corrosion Control by Fuel Additives (Contaminated Fuels).

    DTIC Science & Technology

    1987-06-01

    ABSTRACT The potential of fuel additives to minimize corrosion of blade material in gas turbine engines has been analyzed by the following series of steps...INTRODUCTION High chrome steels and superalloys, which are used extensively for high temperature boilers and gas turbine (GT) engines and related...combustion gases onto turbine blades and other hot components. Among the factors expected to affect the corrosion resis

  11. Transect studies on pine litter organic matter: decomposition and chemical properties of upper soil layers in Polish forests

    Treesearch

    Alicja Breymeyer; Marek Degorski; David Reed

    1998-01-01

    The relationship between litter decomposition rate, some chemical properties of upper soil layers (iron, manganese, zinc, copper, lead, mercury, nickel, chrome in humus-mineral horizon-A), and litter (the same eight elements in needle litter fraction) in pine forests of Poland was studied. Heavy metal content in organic-mineral horizon of soils was highly correlated...

  12. Evaluation of the Possibility of Obtaining Tube-to-Tube Sheet Welded Joints of 15Cr5Mo Steel by Alternative Technological Process

    NASA Astrophysics Data System (ADS)

    Rizvanov, R. G.; Mulikov, D. Sh.; Karetnikov, D. V.; Fairushin, A. M.; Tokarev, A. S.

    2018-03-01

    This paper presents the results of the tests of joints of chrome-molybdenum steel, obtained by rotary friction welding. On their basis, conclusions were drawn about the weldability of this type of steel by friction welding, and also the applicability of this welding technology in the manufacture of heat exchange equipment.

  13. UNICOAT. Development Laboratory Characterization and Field Evaluation

    DTIC Science & Technology

    1990-03-30

    flexibility of the coatlig system and prevent cracking of the paint, especially around fasteners. Although the current paint system performs well, the...topcoat formulation that non-lead, non-chroaate, corrosion preventive coatings for aluminum can be develped. Currently, there are two military...specifications, Mil-P-52995 and Mil-P-53030, for lead and chrome free corrogion preventive primers for ferrous and non-ferrous substrates. The pigment system

  14. Hexavalent Chromium Minimization Strategy

    DTIC Science & Technology

    2011-05-01

    Logistics 4 Initiative - DoD Hexavalent Chromium Minimization Non- Chrome Primer IIEXAVAJ ENT CHRO:M I~UMI CHROMIUM (VII Oil CrfVli.J CANCEfl HAnRD CD...Management Office of the Secretary of Defense Hexavalent Chromium Minimization Strategy Report Documentation Page Form ApprovedOMB No. 0704-0188...00-2011 4. TITLE AND SUBTITLE Hexavalent Chromium Minimization Strategy 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  15. Chromate dermatitis from a boiler lining.

    PubMed

    Rycroft, R J; Calnan, C D

    1977-08-01

    Chromate dermatitis is described in a mechanical fitter working inside boiler combustion chambers. A source of hexavalent chromate is traced to the action of the heat and alkaline fuel ash on trivalent chrome ore in parts of the refractory lining. Removal of the patient from this contact has resulted in almost complete clearing of his dermatitis, without any relapse, during a 9-month follow-up period.

  16. Advanced Powder Coating Systems for Military Applications

    DTIC Science & Technology

    2011-05-01

    UVCPC • Conclusions • DoD spends billions of dollars annually on protective organic coatings – Hexavalent chrome primer use still widespread – Contains...Elimination of Hazardous Air Pollutants (HAP) • Reduction/Elimination of ESOH Concerns – Elimination of hexavalent chromium – Elimination of free...production and release; hexavalent chromium; free isocyanates; up to 72 hrs “dry to fly” time Longer cure times than traditional primers and

  17. Perceptions on use of home telemonitoring in patients with long term conditions - concordance with the Health Information Technology Acceptance Model: a qualitative collective case study.

    PubMed

    Middlemass, Jo B; Vos, Jolien; Siriwardena, A Niroshan

    2017-06-26

    Health information technology (HIT) may be used to improve care for increasing numbers of older people with long term conditions (LTCs) who make high demands on health and social care services. Despite its potential benefits for reducing disease exacerbations and hospitalisations, HIT home monitoring is not always accepted by patients. Using the Health Information Technology Acceptance Model (HITAM) this qualitative study examined the usefulness of the model for understanding acceptance of HIT in older people (≥60 years) participating in a RCT for older people with Chronic Obstructive Pulmonary Disease (COPD) and associated heart diseases (CHROMED). An instrumental, collective case study design was used with qualitative interviews of patients in the intervention arm of CHROMED. These were conducted at two time points, one shortly after installation of equipment and again at the end of (or withdrawal from) the study. We used Framework Analysis to examine how well the HITAM accounted for the data. Participants included 21 patients aged between 60-99 years and their partners or relatives where applicable. Additional concepts for the HITAM for older people included: concerns regarding health professional access and attachment; heightened illness anxiety and desire to avoid continuation of the 'sick-role'. In the technology zone, HIT self-efficacy was associated with good organisational processes and informal support; while ease of use was connected to equipment design being suitable for older people. HIT perceived usefulness was related to establishing trends in health status, detecting early signs of infection and potential to self-manage. Due to limited feedback to users opportunities to self-manage were reduced. HITAM helped understand the likelihood that older people with LTCs would use HIT, but did not explain how this might result in improved self-management. In order to increase HIT acceptance among older people, equipment design and organisational factors need to be considered. ClinicalTrials.gov Identifier: NCT01960907 October 9 2013 (retrospectively registered) Clinical tRials fOr elderly patients with MultiplE Disease (CHROMED). Start date October 2012, end date March 2016. Date of enrolment of the first participant was February 2013.

  18. Groundwater quality appraisal and its hydrochemical characterization in Ghaziabad (a region of indo-gangetic plain), Uttar Pradesh, India

    NASA Astrophysics Data System (ADS)

    Singh, Uday Veer; Abhishek, Amar; Singh, Kunwar P.; Dhakate, Ratnakar; Singh, Netra Pal

    2014-06-01

    India's growing population enhances great pressure on groundwater resources. The Ghaziabad region is located in the northern Indo-Gangetic alluvium plain of India. Increased population and industrial activities make it imperative to appraise the quality of groundwater system to ensure long-term sustainability of resources. A total number of 250 groundwater samples were collected in two different seasons, viz., pre-monsoon and post monsoon and analyzed for major physico-chemical parameters. Broad range and great standard deviation occurs for most parameters, indicating chemical composition of groundwater affected by process, including water-rock interaction and anthropogenic effect. Iron was found as predominant heavy metal in groundwater samples followed by copper and lead. An exceptional high concentration of Chromium was found in some locations. Industrial activities as chrome plating and wood preservative are the key source to metal pollution in Ghaziabad region. On the basis of classification the area water shows normal sulfate, chloride and bi-carbonate type, respectively. Base-exchange indices classified 76 % of the groundwater sources was the sodium-bicarbonate type. The meteoric genesis indices demonstrated that 80 % of groundwater sources belong to a shallow meteoric water percolation type. Chadha's diagram suggested that the hydro-chemical faces belong to the HCO3 - dominant Ca2+-Mg2+ type along with Cl--dominant Ca2+-Mg2+-type. There was no significant change in pollution parameters in the selected seasons. Comparison of groundwater quality with Indian standards proves that majority of water samples are suitable for irrigation purposes but not for drinking.

  19. A broadband THz receiver for low background space applications

    NASA Technical Reports Server (NTRS)

    Hagmann, C.; Benford, D. J.; Clapp, A. C.; Richards, P. L.; Timbie, P.

    1992-01-01

    We have developed a sensitive bolometric receiver for low background space applications. In a 10 percent bandwidth at 1 THz, this receiver is approximately 100 times more sensitive than a quantum limited heterodyne receiver with a 1 GHz IF bandwidth. This receiver is designed to be used for the long wavelength band (200-700 microns) in the MIPS instrument on NASA's SIRTF satellite. The bolometers are cooled to 100 mK by an adiabatic demagnetization refrigerator. Roughly 60 g of cesium chrome alum salt is partially demagnetized to 100 mK, followed by a slow regulated downramp to compensate for the heat leak. The hold time of the ADR system is about 18 hours with a temperature stability of delta T(sub rms) approx. equals 10 micro-K. The composite bolometers have electrical responsivities of 10(exp 9)V/W and electrical NEP's of about 3x10(exp -17) W/square root of Hz. The bolometer signals are read out by JFET preamplifiers located on the helium plate and operated at 120 K. We have addressed a number of space qualification issues, such as the development of an analog magnet controller, construction of a cryogenic shake-table for bolometers and selection of the paramagnetic salt CCA which can survive a bakeout at 50 C. The receiver is scheduled to be flown in the spring of 1992 on a balloon telescope. This flight has a dual purpose. One is to provide realistic test of the capabilities of the new receiver. The other is to search for anisotropies in the cosmic microwave background on scales of a few degrees.

  20. Prenatal exposure to chromium induces early reproductive senescence by increasing germ cell apoptosis and advancing germ cell cyst breakdown in the F1 offspring.

    PubMed

    Sivakumar, Kirthiram K; Stanley, Jone A; Arosh, Joe A; Pepling, Melissa E; Burghardt, Robert C; Banu, Sakhila K

    2014-04-01

    Hexavalent chromium (CrVI), one of the more toxic heavy metals, is widely used in more than 50 industries such as chrome plating, welding, wood processing and tanneries. As one of the world's leading producers of chromium compounds, the U.S. is facing growing challenges in protecting human health against multiple adverse effects of CrVI. CrVI is rapidly converted to CrIII intracellularly, and can induce apoptosis through different mechanisms. Our previous studies demonstrated postnatal exposure to CrVI results in a delay or arrest in follicle development and puberty. Pregnant rats were treated with 25 ppm potassium dichromate (CrVI) from gestational day (GD) 9.5 to 14.5 through drinking water, placentae were removed on GD 20, and total Cr was estimated in the placentae; ovaries were removed from the F1 offspring on postnatal day (PND)-1 and various analyses were performed. Our results show that gestational exposure to CrVI resulted in (i) increased Cr concentration in the placenta, (ii) increased germ cell apoptosis by up-regulating p53/p27-Bax-caspase-3 proteins and by increasing p53-SOD-2 co-localization; (iii) accelerated germ cell cyst (GCC) breakdown; (iv) advanced primordial follicle assembly and primary follicle transition and (v) down regulation of p-AKT, p-ERK and XIAP. As a result of the above events, CrVI induced early reproductive senescence and decrease in litter size in F1 female progeny. Published by Elsevier Inc.

  1. Prenatal exposure to chromium induces early reproductive senescence by increasing germ cell apoptosis and advancing germ cell cyst breakdown in the F1 offspring

    PubMed Central

    Sivakumar, Kirthiram K.; Stanley, Jone A.; Arosh, Joe A.; Pepling, Melissa E.; Burghardt, Robert C.; Banu, Sakhila K.

    2014-01-01

    Hexavalent chromium (CrVI), one of the more toxic heavy metals, is widely used in more than 50 industries such as chrome plating, welding, wood processing and tanneries. As one of the world’s leading producers of chromium compounds, the U.S. is facing growing challenges in protecting human health against multiple adverse effects of CrVI. CrVI is rapidly converted to CrIII intracellularly, and can induce apoptosis through different mechanisms. Our previous studies demonstrated postnatal exposure to CrVI results in a delay or arrest in follicle development and puberty. Pregnant rats were treated with 25 ppm potassium dichromate (CrVI) from gestational day (GD) 9.5 to 14.5 through drinking water, placentae were removed on GD 20, and total Cr was estimated in the placentae; ovaries were removed from the F1 offspring on postnatal day (PND)-1 and various analyses were performed. Our results show that gestational exposure to CrVI resulted in (i) increased Cr concentration in the placenta, (ii) increased germ cell apoptosis by up-regulating p53/p27–Bax–caspase-3 proteins and by increasing p53–SOD-2 co-localization; (iii) accelerated germ cell cyst (GCC) breakdown; (iv) advanced primordial follicle assembly and primary follicle transition and (v) down regulation of p-AKT, p-ERK and XIAP. As a result of the above events, CrVI induced early reproductive senescence and decrease in litter size in F1 female progeny. PMID:24530425

  2. Bell Helicopter Advanced Rotocraft Transmission (ART) program

    NASA Technical Reports Server (NTRS)

    Henry, Zachary S.

    1995-01-01

    Future rotorcraft transmissions require key emerging material and component technologies using advanced and innovative design practices in order to meet the requirements for a reduced weight to power ratio, a decreased noise level, and a substantially increased reliability. The specific goals for the future rotorcraft transmission when compared with a current state-of-the-art transmission (SOAT) are: (1) a 25 percent weight reduction; (2) a 10 dB reduction in the transmitted noise level; and (3) a system reliability of 5000 hours mean-time-between-removal (MTBR) for the transmission. This report summarizes the work conducted by Bell Helicopter Textron, Inc. to achieve these goals under the Advanced Rotorcraft Transmission (ART) program from 1988 to 1995. The reference aircraft selected by BHTI for the ART program was the Tactical Tiltrotor which is a 17,000 lb gross weight aircraft. A tradeoff study was conducted comparing the ART with a Selected SOAT. The results showed the ART to be 29 percent lighter and up to 13 dB quieter with a calculated MTBR in excess of 5000 hours. The results of the following high risk component and material tests are also presented: (1) sequential meshing high contact ratio planetary with cantilevered support posts; (2) thin dense chrome plated M50 NiL double row spherical roller planetary bearings; (3) reduced kinematic error and increased bending strength spiral bevel gears; (4) high temperature WE43 magnesium housing evaluation and coupon corrosion tests; (5) flexure fatigue tests of precision forged coupons simulating precision forged gear teeth; and (6) flexure fatigue tests of plasma carburized coupons simulating plasma carburized gear teeth.

  3. Geomorphic Evolution and Slip rate Measurements of the Noushki Segment , Chaman Fault Zone, Pakistan

    NASA Astrophysics Data System (ADS)

    Abubakar, Y.; Khan, S. D.; Owen, L. A.; Khan, A.

    2012-12-01

    The Nushki segment of the Chaman fault system is unique in its nature as it records both the imprints of oblique convergence along the western Indian Plate boundary as well as the deformation along the Makran subduction zone. The left-lateral Chaman transform zone has evolved from a subduction zone along the Arabian-Eurasian collision complex to a strike-slip fault system since the collision of the Indian Plate with the Eurasia. The geodetically and geologically constrained displacement rates along the Chaman fault varies from about 18 mm/yr to about 35 mm/yr respectively throughout its total length of ~ 860 km. Two major hypothesis has been proposed by workers for these variations; i) Variations in rates of elastic strain accumulation along the plate boundary and, ii) strain partitioning along the plate boundary. Morphotectonic analysis is a very useful tool in investigations of spatial variations in tectonic activities both regionally and locally. This work uses morphotectonic analysis to investigate the degree of variations in active tectonic deformation, which can be directly related to elastic strain accumulation and other kinematics in the western boundary of the plate margin. Geomorphic mapping was carried out using remotely sensed data. ASTER and RADAR data were used in establishing Quaternary stratigraphy and measurement of geomorphic indices such as stream length gradient index, valley floor width to height ratio and, river/stream longitudinal profile within the study area. High resolution satellite images (e.g., IKONOS imagery) and 30m ASTER DEMs were employed to measure displacement recorded by landforms along individual strands of the fault. Results from geomorphic analysis shows three distinct levels of tectonic deformation. Areas showing high levels of tectonic deformation are characterized by displaced fan surfaces, deflected streams and beheaded streams. Terrestrial Cosmogenic nuclide surface exposure dating of the displaced landforms is being carried out to calculate slip-rates. Slip-rates estimation along this segment of this plate boundary will help in understanding of tectonic evolution of this plate boundary and seismic activity in the region.

  4. Application of bacteriophages to reduce Salmonella contamination on workers' boots in rendering-processing environment.

    PubMed

    Gong, C; Jiang, X; Wang, J

    2017-10-01

    Workers' boots are considered one of the re-contamination routes of Salmonella for rendered meals in the rendering-processing environment. This study was conducted to evaluate the efficacy of a bacteriophage cocktail for reducing Salmonella on workers' boots and ultimately for preventing Salmonella re-contamination of rendered meals. Under laboratory conditions, biofilms of Salmonella Typhimurium avirulent strain 8243 formed on rubber templates or boots were treated with a bacteriophage cocktail of 6 strains (ca. 9 log PFU/mL) for 6 h at room temperature. Bacteriophage treatments combined with sodium hypochlorite (400 ppm) or 30-second brush scrubbing also were investigated for a synergistic effect on reducing Salmonella biofilms. Sodium magnesium (SM) buffer and sodium hypochlorite (400 ppm) were used as controls. To reduce indigenous Salmonella on workers' boots, a field study was conducted to apply a bacteriophage cocktail and other combined treatments 3 times within one wk in a rendering-processing environment. Prior to and after bacteriophage treatments, Salmonella populations on the soles of rubber boots were swabbed and enumerated on XLT-4, Miller-Mallinson or CHROMagar™ plates. Under laboratory conditions, Salmonella biofilms formed on rubber templates and boots were reduced by 95.1 to 99.999% and 91.5 to 99.2%, respectively. In a rendering-processing environment (ave. temperature: 19.3°C; ave. relative humidity: 48%), indigenous Salmonella populations on workers' boots were reduced by 84.2, 92.9, and 93.2% after being treated with bacteriophages alone, bacteriophages + sodium hypochlorite, and bacteriophages + scrubbing for one wk, respectively. Our results demonstrated the effectiveness of bacteriophage treatments in reducing Salmonella contamination on the boots in both laboratory and the rendering-processing environment. © 2017 Poultry Science Association Inc.

  5. Association between urinary 1-hydroxypyrene and genotoxic effects in coke oven workers

    PubMed Central

    Siwinska, E; Mielzynska, D; Kapka, L

    2004-01-01

    Methods: Blood and urine samples were collected immediately after a shift at the end of a working week from 50 coke oven workers and 50 control workers not exposed to PAHs. Methods included: (1) biomarkers of exposure: urinary 1-hydroxypyrene (HpU), urinary mutagenicity by the plate Salmonella test with strains TA98 and YG1024 after metabolic activation, expressed as mutagenic rate (MR98 and MR1024, respectively), urinary cotinine; and (2) biomarkers of biological effects in peripheral blood lymphocytes (PBL): sister chromatid exchanges (SCE/cell), cells of high frequency of SCE (% HFC), micronuclei (MN/1000 cells), chromosomal aberrations (CA/100 cells), and DNA damage by the Comet assay. Results: Occupational exposure to PAH resulted in significantly increased levels of HpU and mutagenic effect of urine. Median values of these biomarkers in coke oven workers were: 9.0 µmol/mol creatinine for HpU, 2.7 for MR98, and 8.2 for MR1024, compared to the controls: HpU = 0.6 µmol/mol creatinine, MR98 = 1.2, and MR1024 = 5.5. Occupational exposure caused significant induction of SCE, HFC, and MN in coke oven workers: median SCE = 5.9, HFC = 12.0%, MN = 6.0 compared to the controls: 3.9, 5.0%, and 3.0, respectively. No effect of occupational exposure was found in relation to CA and DNA damage measured with the Comet assay. HpU concentration was positively associated with SCE and HFC. The concentration of urinary 1-hydroxypyrene corresponding to a 5% probability of increased SCE was 1.0 µmol/mol creatinine. Conclusions: The occupational exposure to PAHs resulted in measurable biological effects (SCE, HFC, MN). In coke oven workers an increased level of SCE was not observed below the level of 1.0 µmol HpU/mol creatinine. PMID:14985527

  6. Influence of subsoil and Soil Volume on the accumulation of nickel by Alyssum corsicum grown on a serpentine soil

    USDA-ARS?s Scientific Manuscript database

    Aims: Test the effect of soil volume and presence of subsoil on Ni hyperaccumulation. Methods: A. corsicum Duby was grown for 3 months on Chrome loam topsoil and subsoil from near Reistertown, MD, in a test of growth and Ni accumulation with varied soil masses (2.8 and 5.6 kg pot-1) to study the im...

  7. Challenges in the Development and Evolution of Secure Open Architecture Command and Control Systems (Briefing Charts)

    DTIC Science & Technology

    2013-06-01

    widgets for an OA system Design-time architecture: Browser, email, widget, DB, OS Go ogle Instance architecture: Chrome, Gmail, Google...provides functionally similar components or applications compatible with an OA system design Firefox Browser, WP, calendar Opera Instance...architecture: Firefox , AbiWord, Evolution, Fedora GPL Ab1Word Google Docs Instance ardlitecture: Fire fox, OR Google cal., Google Docs, Fedora

  8. QuEST: Qualifying Environmentally Sustainable Technologies. Volume 6

    NASA Technical Reports Server (NTRS)

    Lewis, Pattie

    2011-01-01

    QuEST is a publication of the NASA Technology Evaluation for Environmental Risk Mitigation Principal Center (TEERM). This issue contains brief articles on: Risk Identification and Mitigation, Material Management and Substitution Efforts--Hexavalent Chrome-free Coatings and Low volatile organic compounds (VOCs) Coatings, Lead-Free Electronics, Corn-Based Depainting Media; Alternative Energy Efforts Hydrogen Sensors and Solar Air Conditioning. Other TEERM Efforts include: Energy and Water Management and Remediation Technology Collaboration.

  9. Electroformed Nanocrystalline Coatings: An Advanced Alternative to Hard Chrome Electroplating

    DTIC Science & Technology

    2003-11-21

    hypo/ phosphorous acid was included in the estimate. The cost analysis is given in Table 2-3. The relative consumable cost for the nanocrystalline...concentrations and phosphorous acid concentrations. While the internal stress of the Co- P deposit was affected by changes in the above-mentioned...may be occurring which consumes the phosphorous acid in solution (see Section 2.2). Table 5-1 Hardness at distance from deposit/substrate

  10. USAF Corrosion Prevention and Control Enterprise - Sustainability Links

    DTIC Science & Technology

    2014-11-18

    projects and $84M  Example of potential synergy: From FY05-14, the DoD Corrosion Program funded 21 projects on hexavalent chromium reduction  OSD...coatings, effects on structural integrity, environmental effects, etc  Some topics of interest  Inhibitor mechanisms for mg-rich primer (non- chrome ...approach  Financial and engineering resources are limited  Potential costs of corrosion are significant  Supporting replacements for hexavalent

  11. Safe disposal of toxic chrome buffing dust generated from leather industries.

    PubMed

    Swarnalatha, S; Srinivasulu, T; Srimurali, M; Sekaran, G

    2008-01-31

    The high concentration of trivalent chromium along with organic/inorganic compounds in chrome buffing dust (CBD), the solid waste discharged from leather industries, causes severe groundwater contamination on land co-disposal and chronic air pollution during thermal incineration. In the present investigation, CBD was subjected to starved air incineration (SAI) at 800 degrees C in a thermal incinerator under different flow rates of oxygen to optimize the oxygen required to incinerate the organic compounds and simultaneously preventing the conversion of Cr(3+) to Cr(6+). The energy audit of SAI of buffing dust under the external supply of oxygen was carried out under different incineration conditions. The bottom ash from SAI was effectively solidified/stabilized using Portland cement and fine aggregate. The solidified blocks were tested for unconfined compressive strength and heavy metal leaching. Unconfined compressive strength of the blocks was in the range of 120-180 kg/cm(2). The stabilization of chromium(III) in the cement gel matrix was confirmed using Scanning Electron Microscopy SEM, Electron Paramagnetic Resonance spectroscopy (EPR) and X-ray diffraction spectroscopy (XRD). Leachability studies through TCLP on solidified blocks were carried out to determine the degree of leaching of chromium and organic compounds (expressed as COD) under standard conditions.

  12. Optical and spectroscopic studies on tannery wastes as a possible source of organic semiconductors

    NASA Astrophysics Data System (ADS)

    Nashy, El-Shahat H. A.; Al-Ashkar, Emad; Abdel Moez, A.

    2012-02-01

    Tanning industry produces a large quantity of solid wastes which contain hide proteins in the form of protein shavings containing chromium salts. The chromium wastes are the main concern from an environmental stand point of view, because chrome wastes posses a significant disposal problem. The present work is devoted to investigate the possibility of utilizing these wastes as a source of organic semi-conductors as an alternative method instead of the conventional ones. The chemical characterization of these wastes was determined. In addition, the Horizontal Attenuated Total Reflection (HATR) FT-IR spectroscopic analysis and optical parameters were also carried out for chromated samples. The study showed that the chromated samples had suitable absorbance and transmittance in the wavelength range (500-850 nm). Presence of chromium salt in the collagen samples increases the absorbance which improves the optical properties of the studied samples and leads to decrease the optical energy gap. The obtained optical energy gap gives an impression that the environmentally hazardous chrome shavings wastes can be utilized as a possible source of natural organic semiconductors with direct and indirect energy gap. This work opens the door to use some hazardous wastes in the manufacture of electronic devices such as IR-detectors, solar cells and also as solar cell windows.

  13. Size of metallic and polyethylene debris particles in failed cemented total hip replacements

    NASA Technical Reports Server (NTRS)

    Lee, J. M.; Salvati, E. A.; Betts, F.; DiCarlo, E. F.; Doty, S. B.; Bullough, P. G.

    1992-01-01

    Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from 30 cases in which the femoral component was of titanium alloy (10), cobalt-chrome alloy (10), or stainless steel (10). The mean size of metallic particles with the isolation method was 0.8 to 1.0 microns by 1.5 to 1.8 microns. The non-isolation method gave a significantly smaller mean size of 0.3 to 0.4 microns by 0.6 to 0.7 microns. For each technique the particle sizes of the three metals were similar. The mean size of polyethylene particles was 2 to 4 microns by 8 to 13 microns. They were larger in tissue retrieved from failed titanium-alloy implants than from cobalt-chrome and stainless-steel implants. Our results suggest that factors other than the size of the metal particles, such as the constituents of the alloy, and the amount and speed of generation of debris, may be more important in the failure of hip replacements.

  14. Occupational dermatoses reported in Brazil from 2007 to 2014*

    PubMed Central

    Lise, Michelle Larissa Zini; Feijó, Fernando Ribas; Lise, Michael Laurence Zini; Lise, Claudia Ribeiro Zini; de Campos, Luis Carlos Elejalde

    2018-01-01

    Background Occupational diseases are very prevalent in the world, especially in developing countries. Occupational dermatoses are responsible for most of these cases. However, epidemiological studies are rare in Brazil. Objectives To verify the panorama of occupational skin diseases in Brazil describing frequencies of work-related dermatoses and their sociodemographic and occupational patterns. Methods We used retrospective data from the Notifiable Diseases Information System, (from 2007-2014) tabulated with the Tab program for Windows - TabWin12. We used intentional non-probability sampling and sequential selection, considering all notified occupational dermatoses. Results All cases of occupational dermatoses referred to in the period were analyzed (n = 4710). Males and the age group of 35-49 years were the most affected. The most affected body area was the upper limb (34.2%) and the hand (25.4%). The "causative agent" field in the forms was not filled in 69.4% of cases, with chrome as the most prevalent cause reported (11.8%). ICD-10 codes more prevalent were L23, L24, and L25, corresponding to 34.2% of the sample. In total, 29% of patients needed to take a sick leave. No cases evolved to death and there were 0.2% of total as permanent disability. Study limitations The amount of missing information for various items in the system draws attention. Conclusions Treatment of patients with occupational dermatitis include the identification and removal of the causative agent and specific treatment of the disease. Diagnosis delay in cases of occupational dermatoses brings social and financial consequences to the work and life of workers. PMID:29641693

  15. Tinning/Trimming Robot System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fureigh, M.L.

    In a new surface mount assembly area at AlliedSignal Inc., Kansas City Division (KCD), a tinning/trimming robot system tins and trims the gold-plated leads of surface mount technology (SMT) transistors. The KCD-designed system uses a Unimation PUMA 260 robot, a General Production Devices SP-2000 solder pot; water-soluble Blackstone No. 2508 flux; and a Virtual Industries high-temperature, ESD-conductive, miniature suction cup. After the manual cleaning operation, the processed SMT transistors go to the QUADSTAR Automated Component Placement System for a Radar Logic Assembly. The benefits are reductions in the cost of nonconformance, worker fatigue, and standard hours.

  16. STS-117 Rotating Service Structure move

    NASA Image and Video Library

    2007-01-30

    Workers on Launch Pad 39A get ready to begin the movement of the rotating service structure above them. The RSS has not been rotated for more than a year during the maintenance and upgrades on the pad. Some of the work included sandblasting the structure to remove rust and repainting. In addition, the RSS was jacked up and a new upper-bearing race assembly installed where the RSS pivots against the fixed service structure and a half-inch steel plate added. Pad 39A is being made ready for its first launch in four years, the upcoming STS-117 on March 15.

  17. Exploratory Visual Analytics of a Dynamically Built Network of Nodes in a WebGL-Enabled Browser

    DTIC Science & Technology

    2014-01-01

    dimensionality reduction, feature extraction, high-dimensional data, t-distributed stochastic neighbor embedding, neighbor retrieval visualizer, visual...WebGL-enabled rendering is supported natively by browsers such as the latest Mozilla Firefox , Google Chrome, and Microsoft Internet Explorer 11. At the...appropriate names. The resultant 26-node network is displayed in a Mozilla Firefox browser in figure 2 (also see appendix B). 3 Figure 1. The

  18. SPANISH PEAKS PRIMITIVE AREA, MONTANA.

    USGS Publications Warehouse

    Calkins, James A.; Pattee, Eldon C.

    1984-01-01

    A mineral survey of the Spanish Peaks Primitive Area, Montana, disclosed a small low-grade deposit of demonstrated chromite and asbestos resources. The chances for discovery of additional chrome resources are uncertain and the area has little promise for the occurrence of other mineral or energy resources. A reevaluation, sampling at depth, and testing for possible extensions of the Table Mountain asbestos and chromium deposit should be undertaken in the light of recent interpretations regarding its geologic setting.

  19. MOUNT ZIRKEL WILDERNESS AND VICINITY, COLORADO.

    USGS Publications Warehouse

    Snyder, George L.; Patten, Lowell L.

    1984-01-01

    Several areas of metallic and nonmetallic mineralization have been identified from surface occurrences within the Mount Zirkel Wilderness and vicinity, Colorado. Three areas of probable copper-lead-zinc-silver-gold resource potential, two areas of probable chrome-platinum resource potential, four areas of probable uranium-thorium resource potential, two areas of probable molybdenum resource potential, and one area of probable fluorspar potential were identified. No potential for fossil fuel or geothermal resources was identified.

  20. Silicon-on-Sapphire Waveguides for Widely Tunable Coherent Mid-IR Sources

    DTIC Science & Technology

    2013-09-01

    fabricated using a chrome mask. .......................................... 10 1 1. BACKGROUND The mid- infrared (IR) range between 3 m...leveraging existing sources in telecom and short-wave infrared (SWIR) bands. It has been demonstrated using silicon waveguides on silicon-on-silicon...reported [3]. The approach proposed under this project involves the four-wave mixing of a pump at a SWIR wavelength around 2 m and signals in the near

  1. Gram-Negative Bacterial Wound Infections

    DTIC Science & Technology

    2013-05-01

    chelator 2,2’ dipyridyl (DIP), while the production and secretion of iron chelating compounds, known as siderophores, was tested using the Chrome Azurol S...identical to that of 19606, which includes distinct peaks for DHBA and acinetobactin (Fig. 1, profile 1), while three others (3927, 4498 and 5197) make...17978 antibodies to bacteria cultured under iron-rich or iron-limiting conditions (right peaks on top panels of Fig. 2B). On the other hand, low

  2. Studies of Lanthanide Transport in Metallic Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jinsuo; Taylor, Christopher

    Metallic nuclear fuels were tested in fast reactor programs and performed well. However, metallic fuels have shown the phenomenon of FCCI that are due to deleterious reactions between lanthanide fission products and cladding material. As the burnup is increased, lanthanide fission products that contact with the cladding could react with cladding constituents such as iron and chrome. These reactions produce higher-melting intermetallic compounds and low-melting alloys, and weaken the mechanical integrity.

  3. Aerospace Non Chrome Corrosion Inhibiting Primer Systems

    DTIC Science & Technology

    2009-09-01

    Meet all HSE specifications, TSCA, REACh, Akzo • Strippable • No weight increase over current system • Meet specification requirements for corrosion, not...Positive and negative controls • Primer only and topcoated samples Aerospace Coatings | Title 9 OEM CF Optimization/ Down Selects •Usual issues...found to be true • Good NSS ≠ Good filiform ≠ Good cure ≠ Good application properties • Down select process is to minimize ≠ and move to a balance of

  4. Manufacturing Methods and Technology Project Summary Reports.

    DTIC Science & Technology

    1980-12-01

    deposition of chrome-copper (Cr- Cu ), dry-film photoresist application, photolithographic masking, spray etching, die bonding, ultrasonic...4) cold roll forging. Of these, the cold roll forging process is the most widely used for the pro- duction of steel and low alloy blades. It provides... sprayed Mo- Al -Ni both provide relatively good wear resistance, see Figure 1. The powder -flame sprayed aluminum bronze did not perform as well. 147 -S t. I

  5. Integrated Printed Circuit Board (PCB) Active Cooling With Piezoelectric Actuator

    DTIC Science & Technology

    2012-09-01

    The cooler substrate is a laminated multilayer FR-4 substrate. Individual layers are patterned to support the active element, form a resonant...prepreg epoxy. Individual FR-4 lamina were mechanically machined to pattern each layer. The layers were aligned, stacked, and laminated to form the... laminated with 70/30 copper-nickel alloy or 80/20 nickel-chrome alloy and patterned by means of photolithographic techniques and wet etching in a ferric

  6. S8DR shield examination

    NASA Technical Reports Server (NTRS)

    Mason, D. G.; Mccurnin, W. R.

    1973-01-01

    The SNAP 8 developmental reactor lithium hydride shield was examined after being irradiated for over 7000 hours at relatively low temperature. A crack was located in the seam weld of the containment vessel, probably the result of hot short cracking under thermal stress. The LiH was visually examined at two locations and its appearance was typical of low temperature irradiated LiH. The adherence of the chrome oxide emittance coating was found to be excellent.

  7. The National Shipbuilding Research Program. Shipyard Welding Emission Factor Development

    DTIC Science & Technology

    1999-09-01

    percent composition in the rod/wire. Three specific HAPs of concern were identified: 1. Chrome and chromium compounds; 2. Nickel and nickel compounds...welding processes. These are: 1. Those rod/wires reported to be used in the largest amounts (> 10,000 pounds annually) did not contain chromium or...amounts ranging from less than 1,000 to greater than 10,000 pounds annually contained chromium and chromium compounds in concentrations ranging from

  8. The United States’ National Interests in Central Asia

    DTIC Science & Technology

    2000-03-23

    Street Journal, 16 September 1997. 49 Ibid. 50 McHugh , Jane; Elfers, Steve. “Showtime for Sergeants.” Army Times, Vol 59, Issue 17 (23 November...petroleum, coal, manganese,chrome cant deposits of gold some petroleum, coal, sulfur, gold, uranium, ore, nickel , cobalt, and rare earth metals; uranium...Management Review, April 1999. McHugh , Jane; Elfers, Steve. “Showtime for Sergeants.” Army Times, Vol 59, Issue 17 (23 November 1998. Mikhailov

  9. Chemical & Material Risk Management Initiatives: Reach & Cr6+ Strategies (Briefing Charts)

    DTIC Science & Technology

    2011-02-01

    Definition Acquisition, Technology and Logistics 17 DoD Hexavalent Chromium Minimization Strategy Non‐ Chrome  Primer Acquisition, Technology and...Logistics 18 Hexavalent Chromium (Cr6+) - Some Facts • Cr6+ compounds are wonderful corrosion inhibitors • Cr6+ compounds are highly toxic – We’ve learned...and Logistics 21 DoD Hexavalent Chromium Minimization Policy Acquisition, Technology and Logistics 22 Myth-busters • The DoD policy does not ban the

  10. The Nature of Surface Oxides on Corrosion-Resistant Nickel Alloy Covered by Alkaline Water

    PubMed Central

    2010-01-01

    A nickel alloy with high chrome and molybdenum content was found to form a highly resistive and passive oxide layer. The donor density and mobility of ions in the oxide layer has been determined as a function of the electrical potential when alkaline water layers are on the alloy surface in order to account for the relative inertness of the nickel alloy in corrosive environments. PMID:20672134

  11. Isostatic Gravity Anomalies, Flexure and the Origin of Seaward Dipping Reflectors at Volcanic Rifted Margins

    NASA Astrophysics Data System (ADS)

    Morgan, R. L.; Watts, A. B.

    2016-12-01

    Seaward Dipping Reflectors (SDRs) are ubiquitous features of volcanic rifted continental margins where they comprise characteristic wedge-shaped packages of mainly extrusive lava flows. However, their origin has been disputed with some workers suggesting they form by progressive subsidence of extended crust while others propose they are accommodated within the crust by one or more continent-dipping normal faults. We present here a simple model in which SDRs are formed by successive dykes, which intrude and load the crust causing a surface flexure which is subsequently infilled and then loaded by volcanic material, including lava flows. The model explains the arcuate shape, limited offlap geometries and down-dip thickening of SDRs as observed in seismic reflection profiles. By comparing observed and calculated dips we have been able to constrain the elastic plate model type and the effective elastic thickness of rifted lithosphere, Te. Results suggest a broken rather than continuous plate model and Te in the range 3-15 km. The thickness of the resulting SDR package increases with decreasing Te and decreasing compensation density. Decreasing the Tefor successive loads as rifting progresses produces offlap of sub-packages. We have verified our results using process-oriented gravity modelling, in which the gravity effect of surface volcanic infill loads is calculated and combined with the gravity effect of buried dyke loads. Results show good general agreement between observed Airy isostatic anomalies and calculated gravity anomalies. This suggests that the steep gradient that is often observed in the Airy isostatic gravity anomaly at rifted margins is a useful proxy for the landward edge of the dykes that intrude the crust prior to seafloor spreading, rather than a change in basement elevation at the boundary between oceanic and continental crust, as proposed by previous workers.

  12. Subcellular fractionation by zonal centrifugation of glucose-repressed anaerobically grown Saccharomyces carlsbergensis

    PubMed Central

    Cartledge, T. G.; Lloyd, D.

    1972-01-01

    1. Homogenates were prepared from sphaeroplasts of anaerobically grown, glucoserepressed Saccharomyces carlsbergensis, and the distributions of marker enzymes investigated after zonal centrifugation on sucrose gradients containing 2mm-MgCl2. 2. These homogenates contained no detectable cytochrome c oxidase, succinate–cytochrome c oxidoreductase, succinate–ferricyanide oxidoreductase, l(+)-lactate–cytochrome c oxidoreductase or catalase. Cytochromes a+a3 and c were not detected. 3. Zonal centrifugation of whole homogenates indicated complex density distributions of the sedimentable portions of NADH– and NADPH–cytochrome c oxidoreductases, adenosine triphosphatases (ATPases), adenosine pyrophosphatase (ADPase), pyrophosphatase and acid p-nitrophenyl phosphatase. Several different ATPases were distinguished on the basis of their sensitivities to oligomycin and ouabain. 4. Differential centrifugation of whole homogenates at 105g-min left 80–90% of the protein, dithionite-reducible cytochrome b, acid hydrolases and pyrophosphatase in a supernatant (S1) together with 65 and 56% of the NADH– and NADPH–cytochrome c oxidoreductases respectively, 25% of the ATPases and 71% of the adenosine monophosphatase. 5. Further analysis of supernatant S1 revealed the presence of a class of small particles containing NADPH–cytochrome c oxidoreductases and ATPases. 6. At least four different populations of large particles were distinguished. 7. Electron microscopy indicated that one of these corresponded to `promitochondria' as described by other workers. ImagesPLATE 1PLATE 2PLATE 3 PMID:4405573

  13. History of the Colorado-Wyoming state line diatremes.

    USGS Publications Warehouse

    Collins, D.S.; Heyl, A.V.

    1984-01-01

    Although >90 kimberlite diatremes have been found in the area, it was not until after 1963 that these bodies were correctly identified. The presence of large inclusions of sedimentary rocks had hindered their recognition. In 1975 a diamond crystal 3.5 carats). They are usually colourless, but light-brown, blue-white, pale orange, pale to bright yellow and nearly black crystals occur. Associated minerals, including chrome-diopside, chromite, magnesian ilmenite, pyrope and omphacite, are described.-R.S.M.

  14. Survey of Cyber Moving Target Techniques

    DTIC Science & Technology

    2013-09-25

    Description: Details: The authors propose a very simple form of multivariant execution with two replicas where one replica runs with the stack growing ...upwards and the other runs with the stack growing down. Normally any single architecture only supports the stack growing in one direction, but the...April 2012. 8. “The NX Bit and ASLR,” Tom’s Hardware, 25 March 2009. 9. “Pwn2Own day 2: iPhone, BlackBerry beaten; Chrome, Firefox no-shows,” Ars

  15. Studies on Rheomelanins. VI. The Apparent Lipofuscin Characteristics of Rheomelanins,

    DTIC Science & Technology

    1980-05-01

    of aldchydes formed by the action of periodic acid on non carbohydrate conit-tining unsaturated phosphatides . At present we know only that in the o...A ’mV -5 1. Periodic Acid -Schiff Test 2. Long Ziehl-Neelsen Test for Acid Fast lilpofuscii 3. Alternative Nile Blue Method 4. Schmorl Test 5. Sudan...Black B in Alcohol 6. Chrome Alum Hematoxylin Test 7. Protein Determination 8. Specific Miucoprotein Test 9. Phosphoric Acid -Vanillin Lipid

  16. RDT&E Progress and Plansfor Hexavalent Chromium (Cr6+)

    DTIC Science & Technology

    2011-05-12

    RDT&E Progress and Plans for Hexavalent Chromium (Cr6+) Bruce Sartwell Weapons Systems and Platforms Program Manager E2S2 Conference May 12, 2011...2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE RDT&E Progress and Plansfor Hexavalent Chromium (Cr6+) 5a...Tasks/Projects Surface treatments and soluble inhibitors: 1. Fundamental studies of the Trivalent Chrome Process (TCP) 2. Mechanisms of selected

  17. Demonstrating Nonhexavelent Chrome Steel Conversion Coatings on Stryker High Hard Armor Steel Hatches

    DTIC Science & Technology

    2014-01-01

    29 Draft Joint Test Protocol – Validation of Pretreatments for Steel Armor 68 4.4.7 Rising Step Load (Stress Corrosion Cracking) 4.4.7.1...Cost Assessment 27 9. Schedule of Activities 29 10. Management and Staffing 29 11. References 30 Appendix A. Joint Test Protocol 33 Appendix B...in accordance with the tests delineated in the joint test protocol (JTP) provided in appendix A. The functional performance objectives are

  18. Energy Partitioning and Impulse Dispersion in the Decorated, Tapered, Strongly Nonlinear Granular Alignment: A System with Many Potential Applications

    DTIC Science & Technology

    2010-03-01

    finally discuss some preliminary experimental results using systems with chrome spheres and small Nitinol interstitial grains to present the... Nitinol interstitial grains to present the underlying nonlinear dynamics of this so-called decorated tapered granular alignment. We are specifically...second was the DTC setup. In this case, small Nitinol 2.38 mm diameter particles were in- troduced between the main STC particles so that NDTC=9. 53 The

  19. A novel co-culture model of murine K12 osteosarcoma cells and S. aureus on common orthopedic implant materials: 'the race to the surface' studied in vitro.

    PubMed

    McConda, David B; Karnes, Jonathan M; Hamza, Therwa; Lindsey, Brock A

    2016-07-01

    Infection is a major cause of orthopedic implant failure. There are few studies assessing both tissue cell and bacterial adherence on common orthopedic implant materials in a co-culture environment. An in vitro co-culture model was created using K12 osteosarcoma cells and Staphylococcus aureus in a medium incubated over metal disks for 48 h. The results showed that, in the presence of S. aureus, there were fewer osteosarcoma cells attached to the disks for all substrata tested. There were significantly more osteosarcoma cells adhering to the cobalt chrome than the stainless steel and titanium disks. Overall, in the presence of osteosarcoma cells, there were more bacteria adhering to the disks for all the substrata tested, with significantly more bacteria adhering to the stainless steel disks compared to cobalt chrome and titanium disks. Scanning electron microscopy verified that osteosarcoma cells and bacteria were adherent to the metal disks after incubation for 48 h. Furthermore, the observation that more bacteria were in the co-culture than in the control sample suggests that the osteosarcoma cells serve as a nutrient source for the bacteria. Future models assessing the interaction of osteogenic cells with bacteria on a substratum would be improved if the model accounted for the role of the immune system in secondary bone healing.

  20. Optical and spectroscopic studies on tannery wastes as a possible source of organic semiconductors.

    PubMed

    Nashy, El-Shahat H A; Al-Ashkar, Emad; Moez, A Abdel

    2012-02-01

    Tanning industry produces a large quantity of solid wastes which contain hide proteins in the form of protein shavings containing chromium salts. The chromium wastes are the main concern from an environmental stand point of view, because chrome wastes posses a significant disposal problem. The present work is devoted to investigate the possibility of utilizing these wastes as a source of organic semi-conductors as an alternative method instead of the conventional ones. The chemical characterization of these wastes was determined. In addition, the Horizontal Attenuated Total Reflection (HATR) FT-IR spectroscopic analysis and optical parameters were also carried out for chromated samples. The study showed that the chromated samples had suitable absorbance and transmittance in the wavelength range (500-850 nm). Presence of chromium salt in the collagen samples increases the absorbance which improves the optical properties of the studied samples and leads to decrease the optical energy gap. The obtained optical energy gap gives an impression that the environmentally hazardous chrome shavings wastes can be utilized as a possible source of natural organic semiconductors with direct and indirect energy gap. This work opens the door to use some hazardous wastes in the manufacture of electronic devices such as IR-detectors, solar cells and also as solar cell windows. Copyright © 2011 Elsevier B.V. All rights reserved.

Top