Thermoelectric power measurement under hydrostatic pressure using a self-clamped pressure cell
NASA Astrophysics Data System (ADS)
Choi, E. S.; Kang, Haeyong; Jo, Y. J.; Kang, W.
2002-08-01
A thermoelectric power (TEP) measurement technique in a self-clamped pressure cell is presented. Thermal and electrical contacts were glued to heaters by Stycast epoxy, which enhances thermal integration. The pressure effect of Chromel-Constantan and Chromel-AuFe0.07% thermocouples are compared to Chromel-Alumel thermocouples, which are known to be pressure insensitive between 4.2 and 300 K. The investigated thermocouples are found to have a small pressure effect; approx][plus-or-minus4% at maximum in the measured temperature and pressure range. Any pressure effect on Au wires was also found to be very small from the pressure-dependent TEP measurement of YBCO superconductor below Tc.
Evaluation of a 6-wire thermocouple psychrometer for determination of in-situ water potentials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loskot, C.L.; Rousseau, J.P.; Kurzmack, M.A.
1994-12-31
A 6-wire, Peltier-type thermocouple psychrometer was designed and evaluated by the U.S. Geological Survey for monitoring in-situ water potentials in dry-drilled boreholes in the unsaturated zone at Yucca Mountain, Nye County, Nevada. The psychrometer consists of a wet-bulb, chromel-constantan, sensing junction and a separate dry-bulb, copper-constantan, reference junction. Two additional reference junctions are formed where the chromel and constantan wires of the wet-bulb sensing junction are soldered to separate, paired, copper, lead wires. In contrast, in the standard 3-wire thermocouple psychrometer, both the wet bulb and dry bulb share a common wire. The new design has resulted in a psychrometermore » that has an expanded range and greater reliability, sensitivity, and accuracy compared to the standard model.« less
Calorimeter measures high nuclear heating rates and their gradients across a reactor test hole
NASA Technical Reports Server (NTRS)
Burwell, D.; Coombe, J. R.; Mc Bride, J.
1970-01-01
Pedestal-type calorimeter measures gamma-ray heating rates from 0.5 to 7.0 watts per gram of aluminum. Nuclear heating rate is a function of cylinder temperature change, measured by four chromel-alumel thermocouples attached to the calorimeter, and known thermoconductivity of the tested material.
Design Parameters Affecting the Accuracy of Isothermal Thermocouples
1975-01-02
Design Parameters Lead Wire Length intekference Accuracy Askew Installation Tungsten / Rhenium Wire Diameter Trajectory Insulation Thickness Heatshield...Summary ................. 73 A-3 Thermodynamic Properties of Tungsten / Rhenium Therm ocouples ............................ 75 A-4 Thermodynamic Properties...were tungsten / rhenium , chromel/alumel, and iron/constbntan, which covered the 0 to 5000, 0 to 2200, and 0 to I-00°F temperatut- ranges, resoectively. in
Development of a Temperature Controller for a Vuilleumier (VM) Cycle Power Cylinder
1975-10-01
mmmmmmmmmmmmmmmimmmmim 25 Du End Cap, Inconel GTAW — ElemHiit Aljmcnd Powder Sheath, Inconel Ceramic Insulation High Tump. Epoxy Bra/e Joint (TYP) imp...8217; M*-4 p WU^JWWWI^^K.BIIIPJ.IU «^J I L|| || M[ ■"■""W 1 —CONTINUID TABLE IX NICKEL- CHROMIUM vs. NICKEL-ALUMINUM (Chromel-Alunwl
Improved Nozzle Testing Techniques in Transonic Flow
1975-10-01
axiale) et comporte un barreau dynamometrique equips de jauges de contrainte. La canne est solidaire d’un ensemble balance-bloc d’alimentation des...s a l’aide de capteurs produisant un signal ilectrique : Pressions : capteurs ä jauges Temperatures : thermocouples Chromel-Alumel - Efforts...barreau dynamometrique a jauges de contrainte. Les signaux eiectriques sont acquis et traites par la chaine automatique de la soufflerie. Les mesures
A Miniature Stem Thermocouple Hygrometer 1
Michel, Burlyn E.
1977-01-01
An unprotected chromel-constantan thermocouple was mounted in a cavity (4 × 2 × 1 mm) with rounded corners in a chrome-plated brass block (10 × 6 × 4 mm). When installed against a soybean (Glycine max [L.] Merr.) xylem face, sealed with caulking gum, and insulated with polyurethane foam and aluminum foil, even rapidly changing stem water potentials could be followed accurately. Temperature gradients can be a problem. PMID:16660155
THERMAL FATIGUE OF INCONEL ALLOY DA718
2016-10-27
this material meets the required improvement and offers a low cost alternative to powder metallurgy Rene’95. However, its thermal fatigue resistance ...remains to be fully clarified. Its nominal chemical composition is shown in Table B-1. In the fully heat treated condition, DA718 consists of a γ...chromel-alumel thermocouple , spot-welded to the mid-length of the specimen. The thermal strain, induced by the expansion and contraction of the
Gemini 9 configured extravehicular spacesuit assembly
1966-05-01
S66-31019 (May 1966) --- Test subject Fred Spross, Crew Systems Division, wears the Gemini-9 configured extravehicular spacesuit assembly. The legs are covered with Chromel R, which is a cloth woven from stainless steel fibers, used to protect the astronaut and suit from the hot exhaust thrust of the Astronaut Maneuvering Unit (AMU). Astronaut Eugene A. Cernan will wear this spacesuit during his Gemini-9A extravehicular activity (EVA). Photo credit: NASA
1950-03-15
coil, which has a resistance of 10 ohms, is surrounding the return pipe and by the tubular made of Chromel A or Nichrome V ’ibbon, coil, P, connected...stopcock. In filling the picnometer the liquid isplaced in funnel G and drawn in through E by exhausting the air through F. By this procedure much...instead of the original fairly constant by leakage through a screw pinch- vibrator head. This special head consists of a cock, P. If the maximum vacuum is
Fabrication of thin film heat flux sensors
NASA Technical Reports Server (NTRS)
Will, Herbert
1991-01-01
Thin-film heat-flux sensors have been constructed in the form of arrays of thermocouples on upper and lower surfaces of an insulating layer, so that flux values are proportional to the temperature difference across the upper and lower surface of the insulation material. The sensor thermocouples are connected in thermopile arrangement, and the structure is patterned with photolithographic techniques. Both chromel-alumel and Pt-Pt/Rh thermocouples have been devised; the later produced 28 microvolts when exposed to the radiation of a 1000 C furnace.
2010-02-01
the flue gas was measured with an S-type Pitot tube connected to an inclined oil manometer, and the temperature of the flue gas was measured with a...umbilical line, a vacuum pump, a dry gas meter, and a calibrated orifice connected to an inclined oil manometer. The moisture content was less than 2% so...flue gas was measured with an S-type Pitot tube connected to an inclined oil manometer, and the temperature of the flue gas was measured with a chromel
1966-05-01
S66-33162 (May 1966) --- Test subject Fred Spross, Crew Systems Division, wears configured extravehicular spacesuit assembly and Extravehicular Life Support System chest pack. The spacesuit legs are covered with Chromel R, which is a cloth woven from stainless steel fibers, used to protect the suit and astronaut from the hot exhaust thrust of the Astronaut Maneuvering Unit backpack. The Gemini spacesuit, backpack and chest pack comprise the AMU, a system which is essentially a miniature manned spacecraft. Astronaut Eugene A. Cernan will wear the AMU during his Gemini-9A extravehicular activity (EVA). Photo credit: NASA
Probe Measures Fouling As In Heat Exchangers
NASA Technical Reports Server (NTRS)
Marner, Wilbur J.; Macdavid, Kenton S.
1990-01-01
Combustion deposits reduce transfer of heat. Instrument measures fouling like that on gas side of heat exchanger in direct-fired boiler or heat-recovery system. Heat-flux probe includes tube with embedded meter in outer shell. Combustion gases flow over probe, and fouling accumulates on it, just as fouling would on heat exchanger. Embedded heat-flow meter is sandwich structure in which thin Chromel layers and middle alloy form thermopile. Users determine when fouling approaches unacceptable levels so they schedule cleaning and avoid decreased transfer of heat and increased drop in pressure fouling causes. Avoids cost of premature, unnecessary maintenance.
BOREAS TE-6 1994 Soil and Air Temperatures in the NSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Curd, Shelaine (Editor); Norman, John; Wilson, Tim
2000-01-01
The BOREAS TE-6 team collected several data sets to examine the influence of vegetation, climate, and their interactions on the major carbon fluxes for boreal forest species. This data set contains measurements of the air temperature at a single height and soil temperature at several depths in the NSA from 25-May to 08-Oct- 1994. Chromel-Constantan thermocouple wires run by a miniprogrammable data logger (Model 21X, Campbell Scientific, Inc., Logan, UT) provided direct measurements of temperature. The data are stored in tabular ASCII files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distrobuted Activity Archive Center (DAAC).
A coaxial thermocouple for shock tunnel applications.
Menezes, Viren; Bhat, Sandeep
2010-10-01
A chromel-constantan coaxial surface junction thermocouple has been designed, fabricated, calibrated, and tested to measure the temperature-time history on the surface of a body in a hypersonic freestream of Mach 8 in a shock tunnel. The coaxial thermocouple with a diameter of 3.25 mm was flush mounted in the surface of a hemisphere of 25 mm diameter. The hypersonic freestream was of a very low temperature and density, and had a flow time of about a millisecond. Preliminary test results indicate that the thermocouple is quite sensitive to low temperature-rarefied freestreams, and also has a response time of a few microseconds (≈5 μs) to meet the requirements of short duration transient measurements. The sensor developed is accurate, robust, reproducible, and is highly inexpensive.
Investigation of factors affecting the heater wire method of calibrating fine wire thermocouples
NASA Technical Reports Server (NTRS)
Keshock, E. G.
1972-01-01
An analytical investigation was made of a transient method of calibrating fine wire thermocouples. The system consisted of a 10 mil diameter standard thermocouple (Pt, Pt-13% Rh) and an 0.8 mil diameter chromel-alumel thermocouple attached to a 20 mil diameter electrically heated platinum wire. The calibration procedure consisted of electrically heating the wire to approximately 2500 F within about a seven-second period in an environment approximating atmospheric conditions at 120,000 feet. Rapid periodic readout of the standard and fine wire thermocouple signals permitted a comparison of the two temperature indications. An analysis was performed which indicated that the temperature distortion at the heater wire produced by the thermocouple junctions appears to be of negligible magnitude. Consequently, the calibration technique appears to be basically sound, although several practical changes which appear desirable are presented and discussed. Additional investigation is warranted to evaluate radiation effects and transient response characteristics.
Evaluation of miniature single-wire sheathed thermocouples for turbine blade temperature measurement
NASA Technical Reports Server (NTRS)
Hollanda, R.
1979-01-01
Chromel Alumel thermocouples were used, with sheath diameters of 0.15 and 0.25 mm. Tests were conducted at temperatures ranging from 750 to 1250 K. Both steady state and thermal cycling tests were performed for times up to 200 hours. Initial testing was performed in a low velocity gas stream for long time periods using a Meker-type burner. Additional testing was done in a high velocity gas stream for short time periods using a hot gas tunnel and also in a J75 jet engine. A total of eleven 0.15 mm diameter thermocouples and six 0.25 mm diameter thermocouples were tested. Drift rates up to 2.5% in 10 hours were observed. Photomicrographs show that this design is near the limit of miniaturization based on present manufacturing capabilities. Results indicate that the effects of miniaturization on reliability and accuracy must be considered when choosing thermocouples for a particular application.
Miniature sheathed thermocouples for turbine blade temperature measurement
NASA Technical Reports Server (NTRS)
Holanda, R.; Glawe, G. E.; Krause, L. N.
1974-01-01
An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.
[Perforated duodenal diverticula. Case report and treatment options].
Guardado-Bermúdez, Fernando; Ardisson-Zamora, Fernando Josafat; Rojas-González, Juan Daniel; Medina-Benítez, Alberto; Corona-Suárez, Fernando
2013-01-01
the presence of duodenal diverticula was first described in 1710 by Chromel. Duodenal diverticulum is the second most common site of diverticula in the digestive tract. Anatomically duodenal diverticula are located in 10 to 67% in the second portion of duodenum, and its finding in most cases incidental. About 90% of patients appear asymptomatic, manifesting symptoms mostly once established complications such as: gastrointestinal bleeding and perforation. 78-years-old woman who attended our Emergency department with dyspnea, moderate epigastralgia, abdominal bloating, constipation and difficulty to pass gas; Laparotomy was performed to identify duodenal diverticulum in the third portion of the duodenum with a perforation of 5 mm in its cupula. It proceeds with diverticulectomy. The diagnosis of duodenal diverticulum as a cause of acute abdomen must be considered in our differential diagnosis in acute abdomen supported by imaging and endoscopy. The surgical management of duodenal diverticulum, in particular the resection of the diverticulum, remains as the recommendation for treatment with less morbidity and a good recovery.
Tripathi, T S; Bala, M; Asokan, K
2014-08-01
We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔT increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tripathi, T. S.; Bala, M.; Asokan, K.
2014-08-01
We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔTmore » increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.« less
Metallic Junction Thermoelectric Device Simulations
NASA Technical Reports Server (NTRS)
Duzik, Adam J.; Choi, Sang H.
2017-01-01
Thermoelectric junctions made of semiconductors have existed in radioisotope thermoelectric generators (RTG) for deep space missions, but are currently being adapted for terrestrial energy harvesting. Unfortunately, these devices are inefficient, operating at only 7% efficiency. This low efficiency has driven efforts to make high-figure-of-merit thermoelectric devices, which require a high electrical conductivity but a low thermal conductivity, a combination that is difficult to achieve. Lowered thermal conductivity has increased efficiency, but at the cost of power output. An alternative setup is to use metallic junctions rather than semiconductors as thermoelectric devices. Metals have orders of magnitude more electrons and electronic conductivities higher than semiconductors, but thermal conductivity is higher as well. To evaluate the viability of metallic junction thermoelectrics, a two dimensional heat transfer MATLAB simulation was constructed to calculate efficiency and power output. High Seebeck coefficient alloys, Chromel (90%Ni-10%Cr) and Constantan (55%Cu-45%Ni), produced efficiencies of around 20-30%. Parameters such as the number of layers of junctions, lateral junction density, and junction sizes for both series- and parallel-connected junctions were explored.
Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakos, James T.; Suo-Anttila, Jill M.; Zepper, Ethan T.
Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of themore » data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .« less
NASA Astrophysics Data System (ADS)
Komlev, Anton A.; Minzhulina, Ekaterina A.; Smirnov, Vladislav V.; Shapovalov, Viktor I.
2018-01-01
The paper describes physical characteristics of the hot target sputtering process, which have not been known before. To switch a magnetron over to the hot target regime, a titanium disk of 1 mm thick with a 1-mm-gap was attached on a 4-mm-thick copper plate cooled by running water. A thermocouple sensor was used to investigate the thermal processes occurring in substrates. The study was performed at the discharge current density of 20-40 mA/cm2 and argon pressure of 3-7 mTorr. The accuracy of temperature measurement appeared to be within ± 5%, due the application of a chromel-copel thermocouple. The study reveals that under these conditions the heating curves have the inflection points positioned proportionally to the discharge current density and argon pressure on a time axis. The inflection point appears in the kinetic curves due to the finite value of the target heating time constant. The study shows that the substrate fixed temperature and substrate heating time constant depend on the argon pressure and relate to the current density by the polynomials of the first and second degrees, respectively. The influence of a target on the substrate heating kinetics is considered in an analytical description by the introduction of a multiplier in the form of an exponential function of time. The results of the research make a novel contribution to the field of the sputtering process.
High-performance coaxial EPR cavity for investigations at elevated temperatures and pressures
NASA Astrophysics Data System (ADS)
Goldberg, Ira B.; McKinney, Ted M.
1984-07-01
A microwave cavity suitable for heating a sample to temperatures above 800 °C within 15 s at gas pressures above 17.5 MPa is reported. The cavity is coaxial and operates in the TE011 mode at frequencies between 9 and 10 GHz. The heating element is constructed of nickel-chromium (i.e., Chromel) wire. It consists of two concentric helices wound in opposite senses (directions) and connected in series so as to minimize the magnetic field generated by the heater current. The heater is potted in magnesium oxide-phosphate ceramic and placed inside of a cylinder made from 50-μm copper foil which provides uniform temperature distribution and shields the heater from the microwave field. This assembly then serves as the heating element and the coaxial conductor of the cavity. The diameter of the coaxial heater assembly is approximately 7 mm. The sample is confined by a cylindrical quartz cuvette which surrounds the coaxial conductor. Sample thicknesses of 0.2 to 1.0 mm can be used. Heating from room temperature to 800 °C requires between 15 and 20 s. Operating pressures up to 17 MPa have been used, although the structural design limit of the brass or beryllium copper walls is greater than 22 MPa. Modulation coils are placed in recessed areas of the cavity walls and covered with a thin layer of copper. Cooling water flows through channels cut into the walls to maintain constant microwave parameters. Q factors of 8000 -12 000 can be obtained depending on the sample.
NASA Technical Reports Server (NTRS)
Hideyuki, TANNO; Tomoyuki, KOMURO; Kazuo, SATO; Katsuhiro, ITOH; Lillard, Randolph P.; Olejniczak, Joseph
2013-01-01
An aeroheating measurement test campaign of an Apollo capsule model with laminar and turbulent boundary layer was performed in the free-piston shock tunnel HIEST at JAXA Kakuda Space Center. A 250mm-diameter 6.4%-scaled Apollo CM capsule model made of SUS-304 stainless steel was applied in this study. To measure heat flux distribution, the model was equipped with 88 miniature co-axial Chromel-Constantan thermocouples on the heat shield surface of the model. In order to promote boundary layer transition, a boundary layer trip insert with 13 "pizza-box" isolated roughness elements, which have 1.27mm square, were placed at 17mm below of the model geometric center. Three boundary layer trip inserts with roughness height of k=0.3mm, 0.6mm and 0.8mm were used to identify the appropriate height to induce transition. Heat flux records with or without roughness elements were obtained for model angles of attack 28º under stagnation enthalpy between H(sub 0)=3.5MJ/kg to 21MJ/kg and stagnation pressure between P(sub 0)=14MPa to 60MPa. Under the condition above, Reynolds number based on the model diameter was varied from 0.2 to 1.3 million. With roughness elements, boundary layer became fully turbulent less than H(sub 0)=9MJ/kg condition. However, boundary layer was still laminar over H(sub 0)=13MJ/kg condition even with the highest roughness elements. An additional experiment was also performed to correct unexpected heat flux augmentation observed over H(sub 0)=9MJ/kg condition.
Lopes, Stella Crosara; Pagnano, Valéria Oliveira; Rollo, João Manuel Domingos de Almeida; Leal, Mônica Barbosa; Bezzon, Osvaldo Luiz
2009-01-01
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 °C-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs. PMID:19274398
U.S. Space Radioisotope Power Systems and Applications: Past, Present and Future
NASA Technical Reports Server (NTRS)
Cataldo, Robert L.; Bennett, Gary L.
2011-01-01
Radioisotope power systems (RPS) have been essential to the U.S. exploration of outer space. RPS have two primary uses: electrical power and thermal power. To provide electrical power, the RPS uses the heat produced by the natural decay of a radioisotope (e.g., plutonium-238 in U.S. RPS) to drive a converter (e.g., thermoelectric elements or Stirling linear alternator). As a thermal power source the heat is conducted to whatever component on the spacecraft needs to be kept warm; this heat can be produced by a radioisotope heater unit (RHU) or by using the excess heat of a radioisotope thermoelectric generator (RTG). As of 2010, the U.S. has launched 41 RTGs on 26 space systems. These space systems have ranged from navigational satellites to challenging outer planet missions such as Pioneer 10/11, Voyager 1/2, Galileo, Ulysses, Cassini and the New Horizons mission to Pluto. In the fall of 2011, NASA plans to launch the Mars Science Laboratory (MSL) that will employ the new Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) as the principal power source. Hundreds of radioisotope heater units (RHUs) have been launched to provide warmth to Apollo 11, used to provide heating of critical components in a seismic experiment package, Pioneer 10/11, Voyager 1/2, Galileo, Cassini, Mars Pathfinder, MER rovers, etc. to provide temperature control to critical spacecraft electronics and other mechanical devices such as propulsion system propellant valves. A radioisotope (electrical) power source or system (RPS) consists of three basic elements: (1) the radioisotope heat source that provides the thermal power, (2) the converter that transforms the thermal power into electrical power and (3) the heat rejection radiator. Figure 1 illustrates the basic features of an RPS. The idea of a radioisotope power source follows closely after the early investigations of radioactivity by researchers such as Henri Becquerel (1852-1908), Marie Curie (1867-1935), Pierre Curie (1859-1906) and R. J. Strut. Almost 100 years ago, in 1913, English physicist H. G. J. Moseley (1887-1915) constructed the first nuclear battery using a vacuum flask and 20 mCi of radium (Corliss and Harvey, 1964, Proceedings of the Royal Society, 1913). After World War II, serious interest in radioisotope power systems in the U.S. was sparked by studies of space satellites such as North American Aviation s 1947 report on nuclear space power and the RAND Corporation s 1949 report on radioisotope power. (Greenfield, 1947, Gendler and Kock, 1949). Radioisotopes were also considered in early studies of nuclear-powered aircraft (Corliss and Harvey, 1964). In 1951, the U.S. Atomic Energy Commission (AEC) signed several contracts to study a 1-kWe space power plant using reactors or radioisotopes. Several of these studies, which were completed in 1952, recommended the use of RPS. (Corliss and Harvey, 1964). In 1954, the RAND Corporation issued the summary report of the Project Feedback military satellite study in which radioisotope power was considered (Lipp and Salter, 1954, RAND). Paralleling these studies, in 1954, K. C. Jordan and J. H. Birden of the AEC s Mound Laboratory conceived and built the first RTG using chromel-constantan thermocouples and a polonium-210 (210Po or Po-210) radioisotope heat source (see Figure 2). While the power produced (1.8 mWe) was low by today s standards, this first RTG showed the feasibility of RPS. A second thermal battery was built with more Po-210, producing 9.4 mWe. Jordan and Birden concluded that the Po-210 thermal battery would have about ten times the energy of ordinary dry cells of the same mass (Jordan and Birden, 1954). The heat source consisted of a 1-cm-diameter sphere of 57 Ci (1.8 Wt) of Po-210 inside a capsule of nickel-coated cold-rolled steel all inside a container of Lucite. The thermocouples were silver-soldered chromel-constantan. The thermal battery produced 1.8 mWe.
NASA Astrophysics Data System (ADS)
Boltenko, E. A.
2016-10-01
The results of the experimental study of the heat-transfer crisis on heat-release surfaces of annular channels with swirl and transit flow are presented. The experiments were carried out using electric heated annular channels with one and (or) two heat-release surfaces. For the organization of transit flow on a convex heat-release surface, four longitudinal ribs were installed uniformly at its perimeter. Swirl flow was realized using a capillary wound tightly (without gaps) on the ribs. The ratio between swirl and transit flows in the annular gap was varied by applying longitudinal ribs of different height. The experiments were carried out using a closed-type circulatory system. The experimental data were obtained in a wide range of regime parameters. Both water heated to the temperature less than the saturation temperature and water-steam mixture were fed at the inlet of the channels. For the measurement of the temperature of the heat-release surfaces, chromel-copel thermocouples were used. It was shown that the presence of swirl flow on a convex heatrelease surface led to a significant decrease in critical heat flows (CHF) compared to a smooth surface. To increase CHF, it was proposed to use the interaction of swirl flows of the heat carrier. The second swirl flow was transit flow, i.e., swirl flow with the step equal to infinity. It was shown that CHF values for a channel with swirl and transit flow in all the studied range of regime parameters was higher than CHF values for both a smooth annular channel and a channel with swirl. The empirical ratios describing the dependence of CHF on convex and concave heat-release surfaces of annular channels with swirl and transit flow on the geometrical characteristics of channels and the regime parameters were obtained. The experiments were carried out at the pressure p = 3.0-16.0 MPa and the mass velocity ρw = 250-3000 kg/(m2s).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakos, James Thomas
2004-04-01
It would not be possible to confidently qualify weapon systems performance or validate computer codes without knowing the uncertainty of the experimental data used. This report provides uncertainty estimates associated with thermocouple data for temperature measurements from two of Sandia's large-scale thermal facilities. These two facilities (the Radiant Heat Facility (RHF) and the Lurance Canyon Burn Site (LCBS)) routinely gather data from normal and abnormal thermal environment experiments. They are managed by Fire Science & Technology Department 09132. Uncertainty analyses were performed for several thermocouple (TC) data acquisition systems (DASs) used at the RHF and LCBS. These analyses apply tomore » Type K, chromel-alumel thermocouples of various types: fiberglass sheathed TC wire, mineral-insulated, metal-sheathed (MIMS) TC assemblies, and are easily extended to other TC materials (e.g., copper-constantan). Several DASs were analyzed: (1) A Hewlett-Packard (HP) 3852A system, and (2) several National Instrument (NI) systems. The uncertainty analyses were performed on the entire system from the TC to the DAS output file. Uncertainty sources include TC mounting errors, ANSI standard calibration uncertainty for Type K TC wire, potential errors due to temperature gradients inside connectors, extension wire uncertainty, DAS hardware uncertainties including noise, common mode rejection ratio, digital voltmeter accuracy, mV to temperature conversion, analog to digital conversion, and other possible sources. Typical results for 'normal' environments (e.g., maximum of 300-400 K) showed the total uncertainty to be about {+-}1% of the reading in absolute temperature. In high temperature or high heat flux ('abnormal') thermal environments, total uncertainties range up to {+-}2-3% of the reading (maximum of 1300 K). The higher uncertainties in abnormal thermal environments are caused by increased errors due to the effects of imperfect TC attachment to the test item. 'Best practices' are provided in Section 9 to help the user to obtain the best measurements possible.« less
Enthalpy effects on hypervelocity boundary layers
NASA Astrophysics Data System (ADS)
Adam, Philippe H.
Shots with air and carbon dioxide were carried out in the T5 shock tunnel at GALCIT to study enthalpy effects on hypervelocity boundary layers. The model tested was a 1-meter long, 5-deg half-angle cone. It was instrumented with 51 chromel-constantan coaxial thermocouples and the surface heat transfer rate was computed to deduce the state of the boundary layer. Transitional boundary layers obtained confirm the stabilizing effect of enthalpy. As the reservoir enthalpy is increased, the transition Reynolds number evaluated at the reference conditions increases. This stabilizing effect is more rapid in gases with lower dissociation energy and it seems to level off when no further dissociation can be achieved. Normalizing the reservoir enthalpy with the edge enthalpy appears to collapse the data for all gases onto a single curve. A similar collapse is obtained when normalizing both the transition location and the reservoir enthalpy with the maximum temperature conditions obtained with BLIMPK, a nonequilibrium boundary layer code. The observation that reference conditions are more appropriate to normalize high enthalpy transition data was taken a step further by comparing the tunnel data with results from a reentry experiment. When the edge conditions are used, the tunnel and flight data are around an order of magnitude apart. This is commonly attributed to high disturbance levels in tunnels that cause the boundary layer to transition early. However, when the reference conditions are used instead, the tunnel and flight data come within striking distance of one another although the trends with enthalpy are reversed. This difference could be due to the cone bending and nose blunting. Experimental laminar heat transfer levels were compared to numerical results obtained with BLIMPK. Results for air indicate that the reactions are probably in nonequilibrium and that the wall is catalytic. The catalycity is seen to yield higher surface heat transfer rates than the noncatalytic and frozen chemistry models. The results for carbon dioxide, however, are inconclusive. This is, perhaps, because of inadequate modeling of the reactions. Experimentally, an anomalous yet repeatable, rise in the laminar heat transfer level can be seen at medium enthalpies in carbon dioxide boundary layers.
An Innovative Modeling and Measurement Approach to Improve Rice Water Use Efficiency in California
NASA Astrophysics Data System (ADS)
Montazar, A.; Little, C.; Rejmanek, H.; Tindula, G.; Snyder, R. L.
2014-12-01
California is amongst the top rice producing states in the USA, and more than 95 percent of California's rice is grown in the Sacramento Valley. Based on older literature, the rice water requirement (ETc), ranges between 914 and 1,100 mm. In this study, the actual rice water requirement was measured using the residual of the energy balance method over three paddy rice fields during 2011-2013 seasons in the Sacramento Valley. Net radiation and ground heat flux density were measured, and both eddy covariance (EC) and the surface renewal (SR) technique were employed to determine the sensible heat flux density. The surface renewal method uses high frequency temperature measurements from fine wire thermocouples above the canopy. Mean amplitude and duration of the ramps over half hour periods were determined using a structure function and the characteristics are employed to estimate the direction and magnitude of sensible heat flux using the ratio of the amplitude to the ramp duration as the change in temperature per unit time and the volumetric heat capacity of the air to estimate the magnitude of the heat flux. In the study, 76.2 mm diameter chromel-constantan thermocouples were used to measure high frequency temperature at 10 Hz. The results indicate that there is considerable variability in rice water use both spatially and temporally. The average three-year measured ET of the experimental fields located in Butte County was 734 and 725 mm; and in Colusa County was 771 mm. A typical crop coefficient (Kc) curve was derived from the measured ETc and reference ET (ETo) data. Spatial estimates of monthly climate data from the Sacramento Valley were used to calculate monthly mean ETo, and smooth curve fits of the monthly data gave estimates of typical daily ETo. The daily ETc was calculated as the product of ETo and Kc, and seasonal ETc was calculated by summing the daily ETc values. The results reveal that the seasonal rice ETc was less than earlier estimates. Surface renewal equipment is relatively inexpensive and it provides rice growers with remote monitoring of water consumption by tracking ETc of the paddy fields; and hence assists them to improve rice water use efficiency. The information provided here is useful for determining volumes of water for water transfers and insuring adequate water supplies for optimal production.