21 CFR 878.4830 - Absorbable surgical gut suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... surgical gut suture. (a) Identification. An absorbable surgical gut suture, both plain and chromic, is an...
Maksoud, Mohamed; Koo, Samuel; Barouch, Kasumi; Karimbux, Nadeem
2014-02-01
The aim of the present study was to determine the favoritism of suture materials among a group of clinicians at a teaching institution. The surveys included 11 absorbable and nine non-absorbable sutures. The surveyor was asked to select his or her suture preferences when it comes to using it in 13 different, commonly-performed surgical procedures. The surveys showed overall preferences for non-absorbable versus absorbable sutures. Chromic Gut with a 4-0 diameter thread reverse cutting FS2 needle was the most favored suture. For periodontal bone grafts and hard tissue ridge augmentation, polytetrafluoroethylene with a 4-0 thread and FS2 needle was preferred. For autogenous gingival grafts, gingival allografts, connective tissue grafts, frenectomy and frenoplasty, Chromic Gut with 5-0 diameter thread reverse cutting P3 needle was favored. For extraction socket preservation, soft tissue canine exposure, ridge augmentation, and dental implants, Chromic Gut with 4-0 diameter thread reverse cutting FS2 needle was preferred, and for sinus augmentation, Vicryl with a 4-0 diameter thread reverse cutting FS2 needle was favored. Absorbable sutures were preferred in the majority of periodontal procedures; however, non-absorbable sutures were favored in procedures that required longer healing or better stability of the flap edges in cases of periodontal and ridge augmentation. © 2013 Wiley Publishing Asia Pty Ltd.
Suture material in bladder surgery: a comparison of polydioxanone, polyglactin, and chromic catgut.
Stewart, D W; Buffington, P J; Wacksman, J
1990-06-01
A comparison of polydioxanone, polyglactin, and chromic catgut suture was performed in 120 rat bladders studying propensity for infection, degree of inflammation, calculogenic potential, changes in urine pH, and suture absorption. None of the sutures predisposed to infection and there was wide variability but no correlation in urine pH. Although initially the polydioxanone incited a greater inflammatory response, by six months all three sutures were similar. The absorption of polydioxanone was slower than chromic catgut suture, but similar to the absorption of polyglactin. There was no significant difference in calculogenic potential between the suture materials tested over a six-month period. Based on this study in rats, polydioxanone suture would appear to be equal to catgut and polyglactin suture in bladder surgery.
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2010 CFR
2010-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2014 CFR
2014-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2012 CFR
2012-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2011 CFR
2011-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2013 CFR
2013-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barham, R.E.; Butz, G.W.; Ansell, J.S.
Wound strength in the rectus muscle of rabbits is greater at any measured time interval when sutured with polyglycolic acid than when sutured with chromic catgut. This is true for both irradiated and nonirradiated tissues. No significant advantage is seen for either suture in nonirradiated bladder, although the trend favors polyglycolic acid. In irradiated bladders, a significant advantage is seen for polyglycolic acid at 15 days. In measuring repaired ureteral orifice size, only chromic catgut suture in nonirradiated rabbits caused marked edema and ureteral obstruction. Postoperative ureteral dilation with both materials resolved over a 90 day period. In the irradiatedmore » ureter, however, resolution of this obstruction appears to occur earlier and more dependably when polyglycolic acid suture has been used. Polyglycolic acid showed a trend for superior strength in urothelial wounds tested. The healing of bladder epithelium is usually completed in ten to 14 days. The entire bladder wound gains strength rapidly until day 21 and gains little strength thereafter. A suture material that does not increase the inflammatory response but lasts long enough for complete bladder healing is advisable. Using the criterion of wound breaking strength in our experimental work, polyglycolic acid was shown to be superior to chromic catgut suture material.« less
Effect of human pancreatic juice and bile on the tensile strength of suture materials.
Muftuoglu, M A Tolga; Ozkan, Erkan; Saglam, Abdullah
2004-08-01
Several suture materials are used for pancreatojejunal anastomosis. In this study, we tested the durability of these suture materials in human pancreatic juice and bile. Plain and chromic catgut, polyglactin 910, polyglycolic acid, polydioxanone, polypropylene, and silk sutures were incubated in pancreatic juice and bile that was collected from patients. Fifteen samples of each type of suture material were placed in human juices for 1, 3, and 7 days. Tensile strengths were measured with a tensionmeter. Plain and chromic catgut disintegrated in pancreatic juice and pancreatic juice plus bile mixture. Polyglycolic acid and polyglactin 910 suture materials were vulnerable to pancreatic juice within 7 days. Polydioxanone retained most of its initial strength in pancreatic juice and bile. Polypropylene and silk retained 84% and 92% of their initial strength, respectively. We found that polidioxanone was the strongest suture material in pancreatic juice.
Péterffy, A; Calabrese, E
1979-01-01
A U.S.-made TA-30 model stapling device was utilized to close the bronchial stump in 146 patients, while conventional manual suturing with chromic catgut was performed for the same purpose in 152 patients. The two groups were comparable in respect of pre-operative status and operative diagnosis. Patients, in whom the stapler was utilized, showed a decreased incidence of bronchial fistula (1% vs. 3%) and empyema without fistula (1% vs. 3%). The stapler, compared with conventional manual sutures, allows a simpler and swifter suture of the bronchial stump, reduces the contamination of the operative field, achieves uniform and tighter closure of the bronchus, leaves a better preserved terminal blood perfusion of the stump and utilizes a more tolerated sewing material with less resultant tissue inflammation.
Olah, Z
1979-11-01
The present paper deals with the results of 20 eyes of experimentally operated laboratory animals, whose perforating wounds (of cornea and those of sclerocorneal region) have been suturated with a new type of absorbable synthetic suture material "Dexon" thickness being 6-0. The synthetic absorbable suture material "Dexon" is made of polyglycol acid, and it has been introduced to market by the firm Davis and Geck (U.S.A.). The inflammatory tissue reaction to the presence of the suture material "Dexon" is prominent and can by compared to the reaction to chromic resorbable suture materials (catgut or collagen). The suture material "Dexon" start to resorb in the course of the 2nd-3rd weeks after operation. The suture material "Dexon" can be used at an advantage in the operation where it is possible to cover the knots by a conjuctival lobe (in sclerocorneal region or in strabismus surgery) in this way the tendency to overgrowing of epithelial cells along the suture channels can be prevented. The "Dexon" material is sufficiently flexible and firm and has no antigenic properties, therefore it appears very prospective for ophthalmosurgery.
Poppas, D P; Klioze, S D; Uzzo, R G; Schlossberg, S M
1995-02-01
Laser tissue welding in genitourinary reconstructive surgery has been shown in animal models to decrease operative time, improve healing, and decrease postoperative fistula formation when compared with conventional suture controls. Although the absence of suture material is the ultimate goal, this has not been shown to be practical with current technology for larger repairs. Therefore, suture-assisted laser tissue welding will likely be performed. This study sought to determine the optimal suture to be used during laser welding. The integrity of various organic and synthetic sutures exposed to laser irradiation were analyzed. Sutures studied included gut, clear Vicryl, clear polydioxanone suture (PDS), and violet PDS. Sutures were irradiated with a potassium titanyl phosphate (KTP)-532 laser or an 808-nm diode laser with and without the addition of a light-absorbing chromophore (fluorescein or indocyanine green, respectively). A remote temperature-sensing device obtained real-time surface temperatures during lasing. The average temperature, time, and total energy at break point were recorded. Overall, gut suture achieved significantly higher temperatures and withstood higher average energy delivery at break point with both the KTP-532 and the 808-nm diode lasers compared with all other groups (P < 0.05). Both chromophore-treated groups had higher average temperatures at break point combined with lower average energy. The break-point temperature for all groups other than gut occurred at 91 degrees C or less. The optimal temperature range for tissue welding appears to be between 60 degrees and 80 degrees C. Gut suture offers the greatest margin of error for KTP and 808-nm diode laser welding with or without the use of a chromophore.
21 CFR 878.4830 - Absorbable surgical gut suture.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830 Absorbable...
21 CFR 878.4830 - Absorbable surgical gut suture.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830 Absorbable...
21 CFR 878.4830 - Absorbable surgical gut suture.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830 Absorbable...
21 CFR 878.4830 - Absorbable surgical gut suture.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830 Absorbable...
Effect of Electroacupuncture on Rats with Chronic Constriction Injury-Induced Neuropathic Pain
Tang, Nou-Ying; Lin, Yi-Wen; Li, Tsai-Chung; Liu, Hsu-Jan
2014-01-01
We adopt the chronic constriction injury (CCI) model to induce neuropathic pain to Spragrue-Dawley (SD) rats by ligating the right sciatic nerve of using four 4-0 chromic gut sutures and subsequently applying 2 and 15 Hz electroacupuncture (EA), respectively, to the right (ipsilateral) Zusanli (St-36) and Shangjuxu (St-37) acupoints. The results of this study are summarized as follows: (1) the differences in withdrawal latencies for the radiant heat test and total lift leg counts for the cold plate test (4°C) of the control (i.e., non-EA) and sham groups were greater than those of the 2 Hz EA (2EA) and 15 Hz EA (15EA) groups; (2) the von Frey test filament gram counts of the control and sham groups were less than those of the 2EA and 15EA groups on the 6th, 7th, 8th, 11th, 12th, and 13th day following ligation; and (3) the 2EA and 15EA groups exhibited reduced cerebral transient receptor potential vanilloid type 4 (TRPV4) expressions, although we did not observe a similar effect for cerebral TRPV1 or spinal TRPV4/TRPV1 expressions. These findings show that 2 and 15 Hz EA can reduce CCI-induced neuropathic pain, which indicates that various spinal segmental and gate effects have a crucial function in pain reduction. The relationship between EA and TRPV4/TRPV1 expression requires further study. PMID:24605047
Absorbable synthetic versus catgut suture material for perineal repair
Kettle, Christine
2014-01-01
Background Approximately 70% of women will experience some degree of perineal trauma following vaginal delivery and will require stitches. This may result in perineal pain and superficial dyspareunia. Objectives The objective of this review was to assess the effects of absorbable synthetic suture material as compared with catgut on the amount of short and long term pain experienced by mothers following perineal repair. Search strategy We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register. Selection criteria Randomised trials comparing absorbable synthetic (polyglycolic acid and polyglactin) with plain or chromic catgut suture for perineal repair in mothers after vaginal delivery. Data collection and analysis Trial quality was assessed independently by two reviewers. Data were extracted by one reviewer and checked by the second reviewer. Main results Eight trials were included. Compared with catgut, the polyglycolic acid and polyglactin groups were associated with less pain in first three days (odds ratio 0.62, 95% confidence interval 0.54 to 0.71). There was also less need for analgesia (odds ratio 0.63, 95% confidence interval 0.52 to 0.77) and less suture dehiscence (odds ratio 0.45, 95% confidence interval 0.29 to 0.70). There was no significant difference in long term pain (odds ratio 0.81, 95% confidence interval 0.61 to 1.08). Removal of suture material was significantly more common in the polyglycolic acid and polyglactin groups (odds ratio 2.01, 95% confidence interval 1.56 to 2.58). There was no difference in the amount of dyspareunia experienced by women. Authors’ conclusions Absorbable synthetic suture material (in the form of polyglycolic acid and polyglactin sutures) for perineal repair following childbirth appears to decrease women’s experience of short-term pain. The length of time taken for the synthetic material to be absorbed is of concern. A trial addressing the use of polyglactin has recently been completed and this has been included in this updated review. PMID:10796081
21 CFR 178.3290 - Chromic chloride complexes.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Chromic chloride complexes. 178.3290 Section 178... SANITIZERS Certain Adjuvants and Production Aids § 178.3290 Chromic chloride complexes. Myristo chromic chloride complex and stearato chromic chloride complex may be safely used as release agents in the closure...
Chronic Constriction Injury of the Infraorbital Nerve in the Rat using modified syringe needle
Kernisant, Melanie; Gear, Robert; Jasmin, Luc; Vit, Jean-Philippe; Ohara, Peter T.
2008-01-01
Here we report a method for performing a chronic constriction injury (CCI) of the infraorbital nerve (ION) in the rat as a component of a chronic pain model. The surgical approach to the ION is described together with the use of a modified dental syringe needle that simplifies placing two chromic gut ligatures around the ION. This method makes the surgical procedure easier, the nerve injury more consistent across animals and reduces secondary damage to the ION and surrounding tissue. Pain behavior testing together with immunostaining for markers of nerve injury in the spinal trigeminal nucleus show the suitability of this procedure as a model of orofacial pain. PMID:18501433
Holger, Joel S; Wandersee, Steve C; Hale, David B
2004-07-01
The objective of this study was to compare the 9- to 12-month cosmetic outcome of facial lacerations closed with rapid-absorbing gut suture (RG), octylcyanoacrylate (OC), or nylon suture (NL). We hypothesized that no important differences would exist between these methods. This prospective, randomized study enrolled consecutive patients with facial lacerations when experienced physician assistants were on duty for wound closure. Patients returned at 9 to 12 months for cosmetic evaluation. Two blinded physicians performed visual analog cosmesis scale (VACS) scoring, and the patient completed a VAS satisfaction score. One hundred forty-five patients were enrolled. Nine-month follow up occurred in 84 patients. The maximum difference within each evaluator's set of scores was 3.6 mm, well below the minimum clinically important difference (MCID) of 10 to 15 mm. We did not detect clinically important differences in cosmetic outcome at 9 to 12 months in patients with facial lacerations closed with RG, OC, or NL, although RG or OC could be preferred to eliminate follow-up visits for suture removal.
[History of mechanical sutures in digestive system surgery].
Picardi, Nicola
2002-01-01
The attempts to suture wounds with mechanical device are very old, and their history is lost in the night of times. But more recently--that means less than two century ago--already before the true initial beginning of the modern surgery, after the birth of anaesthesiology with the "ether day--16 october 1846" there have been many efforts to develop new methods to join the tissue of the gut avoiding the danger of peritoneal contamination. The primitive tools of these ancient stapler were founded on the principle to compress with mechanical devices the two sides of the tissue to join. Very early in the past century, well before the appearance of the antibiotics, in the heart of the old Europe were developed and perfectionated devices able to join the intestinal tissue with metallic stitches: the primitive staplers. But after the end of the second world war the development has become bursting, with the progress of the Sovietic Institute of experimental research on surgical tools of Moscow and then with the mighty initiatives of the industrial power in the USA. The more important progress in this field was founded on the standardization of tools designed to fix metallic stitches on the gut, but very recently there are new attempts to use the more old principle of compression-suture on new basis. The results of this development, essential for modern surgery, are the standardization of the surgical technique, the shortening of operative times, and an important support to the new mininvasive approach to digestive surgery.
Anodized aluminum on LDEF: A current status of measurements on chromic acid anodized aluminum
NASA Technical Reports Server (NTRS)
Golden, Johnny L.
1992-01-01
Chromic acid anodize was used as the exterior coating for aluminum surfaces on LDEF to provide passive thermal control. Chromic acid anodized aluminum was also used as test specimens in thermal control coatings experiments. The following is a compilation and analysis of the data obtained thus far.
Zirconium carbide as an electrocatalyst for the chromous-chromic redox couple
NASA Technical Reports Server (NTRS)
Gahn, R. F.; Reid, M. A.; Yang, C. Y. (Inventor)
1981-01-01
Zirconium carbide is used as a catalyst in a REDOX cell for the oxidation of chromous ions to chromic ions and for the reduction of chromic ions to chromous ions. The zirconium carbide is coated on an inert electronically conductive electrode which is present in the anode fluid of the cell.
The corrosion protection of several aluminum alloys by chromic acid and sulfuric acid anodizing
NASA Technical Reports Server (NTRS)
Danford, M. D.
1994-01-01
The corrosion protection afforded 7075-T6, 7075-T3, 6061-T6, and 2024-T3 aluminum alloys by chromic acid and sulfuric acid anodizing was examined using electrochemical techniques. From these studies, it is concluded that sulfuric acid anodizing provides superior corrosion protection compared to chromic acid anodizing.
Abeyta, Cynthia G.; Thomas, C.L.
1996-01-01
The Chromic Acid Pit site is an inactive waste disposal site that is regulated by the Resource Conservation and Recovery Act of 1976. The 2.2-cubic-yard cement-lined pit was operated from 1980 to 1983 by a contractor to the U.S. Army Air Defense Artillery Center and Fort Bliss. The pit, located on the Fort Bliss military reservation, in El Paso, Texas, was used for disposal and evaporation of chromic acid waste generated from chrome plating operations. The site was certified closed in 1989 and the Texas Natural Resources Conservation Commission issued Permit Number HW-50296 (U.S. Environmental Protection Agency Permit Number TX4213720101), which approved and implemented post-closure care for the Chromic Acid Pit site. In accordance with an approved post-closure plan, the U.S. Geological Survey is cooperating with the U.S. Army in evaluating hydrogeologic conditions and ground- water quality at the site. One upgradient and two downgradient ground-water monitoring wells were installed adjacent to the chromic acid pit by a private contractor. Quarterly ground-water sampling of these wells by the U.S. Geological Survey began in December 1993. The Chromic Acid Pit site is situated in the Hueco Bolson intermontane valley. The Hueco Bolson is a primary source of ground water in the El Paso area. City of El Paso and U.S. Army water-supply wells are located on all sides of the study area and are completed 600 to more than 1,200 feet below land surface. The ground-water level in the area of the Chromic Acid Pit site has declined about 25 feet from 1982 to 1993. Depth to water at the Chromic Acid Pit site in September 1994 was about 284 feet below land surface; ground-water flow is to the southeast. Ground-water samples collected from monitoring wells at the Chromic Acid Pit site contained dissolved-solids concentrations of 442 to 564 milligrams per liter. Nitrate as nitrogen concentrations ranged from 2.1 to 2.7 milligrams per liter; nitrite plus nitrate as nitrogen concentrations ranged from 2.3 to 3.0 milligrams per liter. Nitrate concentrations are abnormally high in the Old Mesa well field located about 5,000 feet southwest of the Chromic Acid Pit site. Volatile and semivolatile organic compounds in water samples were analyzed for the first sampling round; no confirmed volatile or semivolatile organic compounds were detected above the laboratory reporting limits. Total chromium concentrations ranged from 0.0099 to 0.092 milligram per liter; dissolved chromium concentrations ranged from 0.0068 to 0.0094 milligram per liter. Overall, water-quality characteristics in water from the chromic acid pit ground-water monitoring wells are similar to those in the surrounding area. Detected chemical concentrations in water from the chromic acid pit monitoring wells during the four sampling periods were below U.S. Environmental Protection Agency-established maximum contaminant levels for public drinking water supplies. Statistical analyses were performed on 39 of the chemical constituents analyzed for in ground water from the chromic acid pit monitoring wells. Concentrations of chloride and fluoride were significantly less in water from the downgradient wells than in water from the upgradient well, whereas concentrations of nitrate as nitrogen, nitrite plus nitrate as nitrogen, and dissolved solids were significantly greater in water from the downgradient wells than in water from the upgradient well. Concentrations of nitrate as nitrogen were significantly different in water from the two downgradient wells. Differences detected through statistical analysis of chemical constituents of water in the chromic acid pit monitoring wells did not appear to indicate a release of hazardous chemicals from the chromic acid pit. There was no indication of ground-water contamination in either downgradient well.
Design and Calibration of a X-Ray Millibeam
2005-12-01
developed for use in Fricke dosimetry , parallel-plate ionization chambers, Lithium Fluoride thermoluminescent dosimetry ( TLD ), and EBT GafChromic...thermoluminescent dosimetry ( TLD ), and EBT GafChromic film to characterize the spatial distribution and accuracy of the doses produced by the Faxitron. A...absorbed dose calibration factors for use in Fricke dosimetry , parallel-plate ionization chambers, Lithium Fluoride (LiF) TLD , and EBT GafChromic film. The
Thin-film sulfuric acid anodizing as a replacement for chromic acid anodizing
NASA Technical Reports Server (NTRS)
Kallenborn, K. J.; Emmons, J. R.
1995-01-01
Chromic acid has long been used to produce a thin, corrosion resistant (Type I) coating on aluminum. Following anodizing, the hardware was sealed using a sodium dichromate solution. Sealing closes up pores inherent in the anodized coating, thus improving corrosion resistance. The thinness of the brittle coating is desirable from a fatigue standpoint, and chromium was absorbed by the coating during the sealing process, further improving corrosion resistance. Unfortunately, both chromic acid and sodium dichromate contain carcinogenic hexavalent chromium. Sulfuric acid is being considered as a replacement for chromic acid. Sulfuric acid of 10-20 percent concentration has traditionally been used to produce relatively thick (Types II and III) or abrasion resistant (Type III) coatings. A more dilute, that is five weight percent, sulfuric acid anodizing process, which produces a thinner coating than Type II or III, with nickel acetate as the sealant has been developed. The process was evaluated in regard to corrosion resistance, throwing power, fatigue life, and processing variable sensitivity, and shows promise as a replacement for the chromic acid process.
Abeyta, Cynthia G.; Roybal, R.G.
1996-01-01
The Chromic Acid Pit site is an inactive waste disposal site that is regulated by the Resource Conservation and Recovery Act of 1976. The 2.2-cubic-yard cement-lined pit was operated from 1980 to 1983 by a contractor to the U.S. Army Air Defense Artillery Center and Fort Bliss. The pit, located on the Fort Bliss military reservation in El Paso, Texas, was used for disposal and evaporation of chromic acid waste generated from chrome plating operations. The site was closed in 1989, and the Texas Natural Resources Conservation Commission issued permit number HW-50296 (U.S. Environmental Protection Agency number TX4213720101), which approved and implemented post-closure care for the Chromic Acid Pit site. In accordance with an approved post-closure plan, the U.S. Geological Survey is cooperating with the U.S. Army in monitoring and evaluating ground-water quality at the site. One upgradient ground-water monitoring well (MW1) and two downgradient ground-water monitoring wells (MW2 and MW3), installed adjacent to the chromic acid pit, are monitored on a quarterly basis. Ground-water sampling of these wells by the U.S. Geological Survey began in December 1993. The ground-water level, measured in a production well located approximately 1,700 feet southeast of the Chromic Acid Pit site, has declined about 29.43 feet from 1982 to 1995. Depth to water at the Chromic Acid Pit site in September 1995 was 284.2 to 286.5 feet below land surface; ground-water flow at the water table is assumed to be toward the southeast. Ground-water samples collected from monitoring wells at the Chromic Acid Pit site during water year 1995 contained dissolved- solids concentrations of 481 to 516 milligrams per liter. Total chromium concentrations detected above the laboratory reporting limit ranged from 0.0061 to 0.030 milligram per liter; dissolved chromium concentrations ranged from 0.0040 to 0.010 milligram per liter. Nitrate as nitrogen concentrations ranged from 2.1 to 2.8 milligrams per liter; nitrite plus nitrate as nitrogen concentrations ranged from 2.4 to 3.2 milligrams per liter. Water samples from wells MW1 and MW2 were analyzed for volatile organic compounds for the first quarter; no confirmed volatile organic compounds were detected above laboratory reporting limits. Detected chemical concentrations in water from the chromic acid pit monitoring wells during the four sampling periods were below U.S. Environmental Protection Agency-established maximum contaminant levels for public drinking-water supplies. Overall, water-quality characteristics of water from the chromic acid pit ground-water monitoring wells are similar to those of other wells in the surrounding area. Statistical analyses were performed on 56 of the chemical constituents analyzed for in ground water from the chromic acid pit monitoring wells. Concentrations of chloride, fluoride, sulfate, and potassium were significantly less in water from one or both downgradient wells than in water from the upgradient well. Concentrations of nitrate as nitrogen, nitrite plus nitrate as nitrogen, and dissolved solids were significantly greater in water from the downgradient wells than in water from the upgradient well. Concentrations of nitrate as nitrogen, chloride, and potassium were significantly different in water from the two downgradient wells. Statistical analysis of chemical constituents in water from the chromic acid pit monitoring wells did not appear to indicate a release of hazardous chemicals from the chromic acid pit. There was no indication of ground-water contamination in either downgradient well.
Cruz, Antonio Augusto Velasco E; Akaishi, Patricia M S; Al-Dufaileej, Mohammed; Galindo-Ferreiro, Alicia
2015-01-01
To describe the use of a lid crease incision for upper eyelid margin rotation in cicatricial entropion combining internal traction on the anterior lamella, tarsotomy, and tarsal overlap without external sutures. Surgical description: The main steps of the procedure consisted of exposure of the entire tarsal plate up to the eyelashes followed by tarsotomy through the conjunctiva. A double-armed 6.0 polyglactin suture was then passed through the distal tarsal fragment to the marginal section of the orbicularis oculi muscle. As the sutures were tied, the distal tarsus advanced over the marginal section, and traction was exerted on the marginal strip of the orbicularis muscle. There were no bolsters or external knots. The pretarsal skin-muscle flap was closed with a 6.0 plain gut suture. We used this procedure at a tertiary hospital in Saudi Arabia from 2013 to 2014. Sixty upper lids of 40 patients (23 women and 17 men) were operated on, with an age range of 44-99 years [mean ± standard deviation (SD) = 70.9 ± 13.01 years]. Bilateral surgery was performed on 21 patients. Follow-up ranged from 1 to 12 months (mean 3.0 ± 2.71 months). Forty percent of the patients (24 lids) had more than 3 months' follow-up. The postoperative lid margin position was good in all cases. Trichiasis (two lashes) was observed in only one patient with unilateral entropion on the medial aspect of the operated lid. The upper lid margin can be effectively rotated through a lid crease incision with internal sutures. The technique combines the main mechanisms of the Wies and Trabut approaches and avoids the use of bolsters or external sutures, which require a second consultation to be removed. Some other lid problems, such as ptosis, retraction, or dermatochalasis, can be concomitantly addressed during the procedure.
1994-02-01
short-gut syndrome, rotomy was conducted to reveal the cranial portion of chronic pain , and female infertility [3, 4]. Many sub- the ileum. The abdominal ...hold the sheets in the proper position. The presence of nal adhesions, chronic abdominal pain , and infertility. Gynecol. suture material acting as a...intra- abdominal landmarks. Opera- of 88 rats were studied with random assignment of ani- tions in this situation are often associated with mals to three
NASA Technical Reports Server (NTRS)
Golden, Johnny L.
1993-01-01
A compilation of reported analyses and results obtained for anodized aluminum flown on the Long Duration Exposure Facility (LDEF) was prepared. Chromic acid, sulfuric acid, and dyed sulfuric acid anodized surfaces were exposed to the space environment. The vast majority of the anodized surface on LDEF was chromic acid anodize because of its selection as a thermal control coating for use on the spacecraft primary structure, trays, tray clamps, and space end thermal covers. Reports indicate that the chromic acid anodize was stable in solar absorptance and thermal emittance, but that contamination effects caused increases in absorptance on surfaces exposed to low atomic oxygen fluences. There were some discrepancies, however, in that some chromic acid anodized specimens exhibited significant increases in absorptance. Sulfuric acid anodized surfaces also appeared stable, although very little surface area was available for evaluation. One type of dyed sulfuric acid anodize was assessed as an optical baffle coating and was observed to have improved infrared absorptance characteristics with exposure on LDEF.
EVALUATION OF AN ELECTRODIALYTIC PROCESS FOR PURIFICATION OF HEXAVALENT CHROMIUM SOLUTIONS
This evaluation addresses the waste reduction and economics of an electrodialytic process that can be used to selectively remove impurities that build up in chromic acid solutions with use. The removal of impurities extends the useful life of the chromic acid solution and avoids ...
Space environmental effects on the integrity of chromic acid anodized coatings
NASA Technical Reports Server (NTRS)
Plagemann, W. L.
1993-01-01
This report describes the condition of chromic acid anodized aluminum subsequent to a 69-month exposure to low Earth orbit (LEO) on the Long Duration Exposure Facility. Optical properties and the condition of anodized coating are reported. This material was exposed to each environmental parameter present in LEO. Only slight changes in the material were observed.
Corrosion Protection of Aluminum
Dalrymple, R. S.; Nelson, W. B.
1963-07-01
Treatment of aluminum-base metal surfaces in an autoclave with an aqueous chromic acid solution of 0.5 to 3% by weight and of pH below 2 for 20 to 50 hrs at 160 to 180 deg C produces an extremely corrosion-resistant aluminum oxidechromium film on the surface. A chromic acid concentration of 1 to 2% and a pH of about 1 are preferred.
A comparison of chromic acid and sulfuric acid anodizing
NASA Technical Reports Server (NTRS)
Danford, M. D.
1992-01-01
Because of federal and state mandates restricting the use of hexavalent chromium, it was deemed worthwhile to compare the corrosion protection afforded 2219-T87 aluminum alloy by both Type I chromic acid and Type II sulfuric acid anodizing per MIL-A-8625. Corrosion measurements were made on large, flat 2219-T87 aluminum alloy sheet material with an area of 1 cm(exp 2) exposed to a corrosive medium of 3.5-percent sodium chloride at pH 5.5. Both ac electrochemical impedance spectroscopy and the dc polarization resistance techniques were employed. The results clearly indicate that the corrosion protection obtained by Type II sulfuric acid anodizing is superior, and no problems should result by substituting Type II sulfuric acid anodizing for Type I chromic acid anodizing.
Results for the Brine Evaporation Bag (BEB) Brine Processing Test
NASA Technical Reports Server (NTRS)
Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin
2015-01-01
The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.
CORROSION PROTECTION OF ALUMINUM
Dalrymple, R.S.; Nelson, W.B.
1963-07-01
Treatment of aluminum-base metal surfaces in an autoclave with an aqueous chromic acid solution of 0.5 to 3% by weight and of pH below 2 for 20 to 50 hrs at 160 to 180 deg C produces an extremely corrosion-resistant aluminum oxidechromium film on the surface. A chromic acid concentration of 1 to 2% and a pH of about 1 are preferred. (D.C.W.)
Jiang, Xiaojun; Chen, Wenchao; Xu, Hongbo
2009-01-01
A method using trivalent chromium has been used to replace hexavalent chromium for the electro-deposition of chromium. Using a tri-chamber bath system various anodic materials and membranes were evaluated to minimize the production of environmentally and health damaging chromic acid. By measuring the absorbance of Cr(VI) at 640 nm, the results indicate that the use of a titanium plated ruthenium (Ti-Ru) anode produces the least amount of chromic acid byproduct compared to lead-gold alloy and graphite anodes. The concentration of Cr(VI) in the immediate vicinity of the Ti-Ru anode decreased from 0.389 mg/L to 0 during a 40-min deposition period. The use of a Nafion(TM) quaternary cation exchange membrane portioning the buffer and anode selectively prevented Cr(III) from entering the anode compartment whilst allowing the migration of H(+) to maintain overall voltaic continuity. It has been demonstrated that the use of a Ti-Ru anode with a Nafion(TM) membrane can eliminate the production of chromic acid associated with the electro-deposition of chromium plate thereby preventing its health damaging exposure to plant operators and preventing discharge of Cr(VI) into the environment. Addition of a surfactant improved current efficiency by 34.7%.
Dover AFB Characterization/Hazardous Waste Management Survey, Dover AFB, Delaware.
1986-07-01
chromium ion (chromate, chromic acid) needs to be reduced to the insoluble trivalent ion ( chromium oxide, chromic hydroxide) to facilitate effective...precipitation. The good removal efficiency seen in the Jar tests indicates the chromium may already be in the trivalent oxidation state, possibly reduced...fails the EP toxicity test for chromium alone, the waste may be excluded from being a hazardous waste, if the chromium is primarily in the trivalent
Installation Restoration Program, Phase I: Records Search, Laughlin Air Force Base, Texas.
1985-03-01
and chemical * cleaning shops and consists of chromic acid, potassium permanganate, cadmium , and descaling solutions. The general trend in waste...0.016 Cadmium ɘ.010 mg/1 ɘ.010 Chromium 0.091 mg/l ɘ.050 Source: LAFB BES, 1984. STP Analysis Results, April 23, 1984. 3-33 -r --r - - - - 41 . N...consists of chromic acid, potassium permanganate, cadmium , and descaling solutions. The fire suppressants currently employed at LAFB and EPAux are AFFF
AGARD Corrosion Handbook. Volume 1. Aircraft Corrosion: Causes and Case Histories
1985-07-01
Anodic coatings can be formed in chromic acid, sulphuric acid, phosphoric acid or oxalic acid solutions. Chromic acid anodizing is widely used with...and consists of a thin non-porous barrier layer next to the metal with a porous outer layer that can be sealed by hydrothermal treatment in steam...anaerobic) or an oxidative (aerobic) mechanism. Various organic acids such as citric acid, oxalic acid, gluconic acid, dodecanoic acid, etc., which may be
Retreatment of Recurrent Cystic Craniopharyngioma With Chromic Phosphorus P 32
Kumar, P.P.; Good, R.R.; Skultety, F.M.; Jones, E.O.; Chu, W.K.
1986-01-01
A cystic craniopharyngioma in a two-year-old boy recurred six months after surgery and postoperative external-beam radiotherapy. Successful retreatment was accomplished with radioisotope injection of 0.5 mCi of chromic phosphorus P 32 into the intracranial cyst, which delivered approximately 300.00 Gy to the cyst wall. The patient's symptoms were relieved, and he is without evidence of disease or cystic fluid accumulation four years after intracavitary 32P irradiation. ImagesFigure 1Figure 2Figure 3 PMID:3735454
Chromic acid anodizing of aluminum foil
NASA Technical Reports Server (NTRS)
Dursch, H.
1988-01-01
The success of the Space Station graphite/epoxy truss structure depends on its ability to endure long-term exposure to the LEO environment, primarily the effects of atomic oxygen and the temperture cycling resulting from the 94 minute orbit. This report describes the development and evaluation of chromic acid anodized (CAA) aluminum foil as protective coatings for these composite tubes. Included are: development of solar absorptance and thermal emittance properties required of Al foil and development of CAA parameters to achieve these optical properties; developing techniques to CAA 25 ft lengths of Al foil; developing bonding processes for wrapping the Al foil to graphite/epoxy tubes; and atomic oxygen testing of the CAA Al foil. Two specifications were developed and are included in the report: Chromic Acid Anodizing of Aluminum Foil Process Specification and Bonding of Anodized Aluminum Foil to Graphite/Epoxy Tubes. Results show that CAA Al foil provides and excellent protective and thermal control coating for the Space Station truss structure.
Deng, Ge; Wu, Kristi; Cruce, Alex A; Bowman, Michael K; Vincent, John B
2015-02-01
Transferrin, the major iron transport protein in the blood, also transports trivalent chromium in vivo. Recent in vitro studies have, however, suggested that the binding of chromic ions to apotransferrin is too slow to be biologically relevant. Nevertheless, the in vitro studies have generally failed to adequately take physiological bicarbonate concentrations into account. In aqueous buffer (with ambient (bi)carbonate concentrations), the binding of chromium to transferrin is too slow to be physiologically relevant, taking days to reach equilibrium with the protein's associated conformational changes. However, in the presence of 25mM (bi)carbonate, the concentration in human blood, chromic ions bind rapidly and tightly to transferrin. Details of the kinetics of chromium binding to human serum transferrin and conalbumin (egg white transferrin) in the presence of bicarbonate and other major potential chromium ligands are described and are consistent with transferrin being the major chromic ion transporter from the blood to tissues. Copyright © 2014 Elsevier Inc. All rights reserved.
Improvements in opti-chromic dosimeters for radiation processing
NASA Astrophysics Data System (ADS)
Humpherys, K. C.; Kantz, A. D.
"Opti-Chromic" dosimeters consisting of radiachromic dye in flourinated polymer tubing have been introduced as a dosimetry system in the range from 10 1 to 5 × 10 4 Gy. Batches of "Opti-Chromic" dosimeters have been produced to evaluate performance under large scale industrial conditions. A systematic study was undertaken to determine the effect of various dosimeter parameters on radiation sensitivity, shelf life, and response characteristics at the higher absorbed doses. These parameters were (A) Type of flourinated polymer tubing; (B) Organic solvent used to activate the radiachromic dye; (C) Concentration of radiachromic dye; (D) Additives to provide proper viscosity, color stability, and high-dose response. Prototype batches were produced and experimental dosimeters exposed to a range of absorbed doses and the response measured as a function of shelf life and dose. The results of the study are presented, and an improved formulation recommended for application to Food Processing. Other formulations may be of value in specific requirements of sensitivity or temperature.
2010-11-18
protection of human subjects. No human subjects were directly involved in this research. FFPPT Materiel Solutions ii Executive Summary The Naval Health...OD 7FR CATHETER BALLOON OCCLUSI EA 6 10 0.180 0.180 918.96 0.300 0.300 1,531.60 C 6840014763011 DISINFECTANT INSTRUMT CIDEX 1GL BT 4S PG 8 1...2-0 1 27IN STRAND NDL T-5 GUT NATURAL BR 36S PG 4 1 0.800 0.120 215.44 0.200 0.030 53.86 B 6515012192747 SUTURE ABS GI SZ 2-0 27IN NDL VICRYL 3S
Ceres model application for increasing preparedness to climate variability in agricultural planning
NASA Astrophysics Data System (ADS)
Popova, Z.; Kercheva, M.
2003-04-01
The paper should demonstrate how knowledge of climate variability and simulation analyses over 30 years could be used to study the vulnerability of maize and wheat ecosystems in the region of Sofia. The procedure of stepwise calibration and validation of agricultural simulation CERES-maize and CERES-wheat models was used at two fields of contrastive soil conditions (Chromic Luvisol and Vertisol). Lysimeters observations under "Chromic Luvisol-maize" combination enabled to test integrally the prediction capacity of CERES-maize, including water and nitrogen fluxes at the boundaries of this vulnerable system over "1.05.1997-1.10.1999" period. The role of soil, crop, climate and irrigation scheduling (under maize only) on drought consequences and groundwater pollution was quantified for four "soil-crop" combinations by CERES models. Four water supply treatments of maize were considered on both soils: one under rainfed conditions and three with varied irrigation application. Water application in initial, development, and mid season growth stages was scheduled by CROPWAT model at any day that soil matrix suction fell to 3.0-3.2 pF with one irrigation scenario and 2.4-2.6 pF with another one. The third drainage-controlling scenario was developed on the basis of 50-75% of the required irrigation depth by satisfying most sensible phases of maize. It was established that "Chromic Luvisol -maize - dry land" combination was associated with the greatest coefficient of variability of yields (Cv=42%) and drought frequency (75% of the years with yield losses more than 20%). Average yield losses in dry vegetation seasons were 60% of the productivity potential under sufficient soil moisture. As a consequence maize cultivation under these conditions was inefficient in 20% of the years when production expenses were greater than losses. Any irrigation practice, even the drainage controlling scenario, mitigated drought consequences on risky soils as Chromic Luvisol by reducing year-to-year variability of yield (CV=5.6-6%). Long-term wheat yields were much more stable (CV=17-23% on Chromic Luvisol) than those of maize. In this case droughts covered 40% of the years when yield losses were 25-30% on the average. Soils of high water holding capacity (as Vertisol) provided additionally 50-150mm-water storage for evapotranspiration and thus reduced frequency of drought under both crops to 20-25% of the years. Agriculture on this soil should be more sustainable (CV=8-8.5% for yield under wheat and CV=14.6% respectively under maize). Reduction of yield during dry vegetation periods was 10-15% under wheat and 22% under maize if compared with productivity under sufficient soil water. Risk assessment of groundwater pollution showed that N-leaching hazards were associated mostly with moderately permeable Chromic Luvisol and high precipitation during the periods of low transpiration rate of both crops. Frequency analyses of seasonal N- losses, proved that half of the wheat and 3% of maize vegetation seasons were susceptible to significant N-leaching (10-45 kg N/ha for "N200" fertilization level) on Chromic Luvisol. Simulated irrigation scenarios did not influence vegetation drainage. Another risky situations occurred in 3% of the years of wet fallow after dry rainfed maize vegetation when up to 30% of fertilization dose might be leached on Chromic Luvisol. Earlier wheat sowing (on the 1st of October) and adjusted fertilization rates and timing to maximum N-uptake under both crops mitigated environmental hazards. Drainage-controlling irrigation scheduling decreased maize fallow state drainage by 30-40 % in half of the years and proved to be economically optimal. Such measure though may tend to increase vulnerability of ecosystem to climate variability by increasing residual soil nitrogen at the end of vegetation.
Sampling and analysis of hexavalent chromium during exposure to chromic acid mist and welding fumes.
Blomquist, G; Nilsson, C A; Nygren, O
1983-12-01
Sampling and analysis of hexavalent chromium during exposure to chromic acid mist and welding fumes. Scand j work environ & health 9 (1983) 489-495. In view of the serious health effects of hexavalent chromium, the problems involved in its sampling and analysis in workroom air have been the subject of much concern. In this paper, the stability problems arising from the reduction of hexavalent to trivalent chromium during sampling, sample storage, and analysis are discussed. Replacement of sulfuric acid by a sodium acetate buffer (pH 4) as a leaching solution prior to analysis with the diphenylcarbazide (DPC) method is suggested and is demonstrated to be necessary in order to avoid reduction. Field samples were taken from two different industrial processes-manual metal arc welding on stainless steel without shield gas and chromium plating. A comparison was made of the DPC method, acidic dissolution with atomic absorption spectrophotometric (AAS) analysis, and the carbonate method. For chromic acid mist, the DPC method and AAS analysis were shown to give the same results. In the analysis of welding fumes, the modified DPC method gave the same results as the laborious and less sensitive carbonate method.
Variable anodic thermal control coating
NASA Technical Reports Server (NTRS)
Gilliland, C. S.; Duckett, J. (Inventor)
1983-01-01
A process for providing a thermal control solar stable surface coating for aluminum surfaces adapted to be exposed to solar radiation wherein selected values within the range of 0.10 to 0.72 thermal emittance (epsilon sub tau) and 0.2 to 0.4 solar absorptance (alpha subs) are reproducibly obtained by anodizing the surface area in a chromic acid solution for a selected period of time. The rate voltage and time, along with the parameters of initial epsilon sub tau and alpha subs, temperature of the chromic acid solution, acid concentration of the solution and the material anodized determines the final values of epsilon/tau sub and alpha sub S. 9 Claims, 5 Drawing Figures.
del Moral, F; Vázquez, J A; Ferrero, J J; Willisch, P; Ramírez, R D; Teijeiro, A; López Medina, A; Andrade, B; Vázquez, J; Salvador, F; Medal, D; Salgado, M; Muñoz, V
2009-09-01
Modern radiotherapy uses complex treatments that necessitate more complex quality assurance procedures. As a continuous medium, GafChromic EBT films offer suitable features for such verification. However, its sensitometric curve is not fully understood in terms of classical theoretical models. In fact, measured optical densities and those predicted by the classical models differ significantly. This difference increases systematically with wider dose ranges. Thus, achieving the accuracy required for intensity-modulated radiotherapy (IMRT) by classical methods is not possible, plecluding their use. As a result, experimental parametrizations, such as polynomial fits, are replacing phenomenological expressions in modern investigations. This article focuses on identifying new theoretical ways to describe sensitometric curves and on evaluating the quality of fit for experimental data based on four proposed models. A whole mathematical formalism starting with a geometrical version of the classical theory is used to develop new expressions for the sensitometric curves. General results from the percolation theory are also used. A flat-bed-scanner-based method was chosen for the film analysis. Different tests were performed, such as consistency of the numeric results for the proposed model and double examination using data from independent researchers. Results show that the percolation-theory-based model provides the best theoretical explanation for the sensitometric behavior of GafChromic films. The different sizes of active centers or monomer crystals of the film are the basis of this model, allowing acquisition of information about the internal structure of the films. Values for the mean size of the active centers were obtained in accordance with technical specifications. In this model, the dynamics of the interaction between the active centers of GafChromic film and radiation is also characterized by means of its interaction cross-section value. The percolation model fulfills the accuracy requirements for quality-control procedures when large ranges of doses are used and offers a physical explanation for the film response.
Chan, S T; Kapadia, C R; Johnson, A W; Radcliffe, A G; Dudley, H A
1983-01-01
Intestinal surgery is usually associated with the parenteral administration of sodium and water, sometimes in amounts considerably in excess of excretory capacity. We have studied the effect of this situation on the water content of the gut at and 5 cm from a single-layer end-to-end anastomosis in the rabbit. Water content was measured by desiccation. One group of animals (group 1) did not receive intravenous therapy. The second group (group 2) received 5 ml kg-1 h-1 of Hartmann's solution during the operative period and thereafter to a total volume of 200 ml by 48 h. In group 1 there was a 5-10 per cent increase in tissue weight both at the anastomotic site and at 5 cm (P less than 0.01, Mann-Whitney U test) on the first 3 days. Thereafter, water content at the anastomosis persisted, but resolved in normal gut. In group 2 a further 5 per cent increase in weight over group 1 occurred (P less than 0.01), persistent at the anastomotic site over 5 days, though resolving elsewhere after 2 days. Extracellular fluid volume expansion exaggerates an anatomical third space present in the region of an anastomosis. At the suture line, oedema so induced is persistent and could be deleterious.
Catalyst surfaces for the chromous/chromic redox couple
NASA Technical Reports Server (NTRS)
Giner, J. D.; Cahill, K. J. (Inventor)
1981-01-01
An electricity producing cell of the reduction-oxidation (REDOX) type divided into two compartments by a membrane is disclosed. A ferrous/ferric couple in a chloride solution serves as a cathode fluid to produce a positive electric potential. A chromic/chromous couple in a chloride solution serves as an anode fluid to produce a negative potential. The electrode is an electrically conductive, inert material plated with copper, silver or gold. A thin layer of lead plates onto the copper, silver or gold layer when the cell is being charged, the lead ions being available from lead chloride which has been added to the anode fluid. If the REDOX cell is then discharged, the lead deplates from the negative electrode and the metal coating on the electrode acts as a catalyst to increase current density.
Water vapor diffusion membranes, 2
NASA Technical Reports Server (NTRS)
Holland, F. F.; Klein, E.; Smith, J. K.; Eyer, C.
1976-01-01
Transport mechanisms were investigated for the three different types of water vapor diffusion membranes. Membranes representing porous wetting and porous nonwetting structures as well as dense diffusive membrane structures were investigated for water permeation rate as a function of: (1) temperature, (2) solids composition in solution, and (3) such hydrodynamic parameters as sweep gas flow rate, solution flow rate and cell geometry. These properties were measured using nitrogen sweep gas to collect the effluent. In addition, the chemical stability to chromic acid-stabilized urine was measured for several of each type of membrane. A technology based on the mechanism of vapor transport was developed, whereby the vapor diffusion rates and relative susceptibility of membranes to fouling and failure could be projected for long-term vapor recovery trials using natural chromic acid-stabilized urine.
Plasma effects on the passive external thermal control coating of Space Station Freedom
NASA Technical Reports Server (NTRS)
Carruth, Ralph, Jr.; Vaughn, Jason A.; Holt, James M.; Werp, Richard; Sudduth, Richard D.
1992-01-01
The current baseline chromic acid anodized thermal control coating on 6061-T6 aluminum meteoroid debris (M/D) shields for SSF has been evaluated. The degradation of the solar absorptance, alpha, and the thermal emittance, epsilon, of chromic acid anodized aluminum due to dielectric breakdown in plasma was measured to predict the on-orbit lifetime of the SSF M/D shields. The lifetime of the thermal control coating was based on the surface temperatures achieved with degradation of the thermal control properties, alpha and epsilon. The temperatures of each M/D shield from first element launch (FEL) through FEL+15 years were analyzed. It is shown that the baseline thermal control coating cannot withstand the -140 V potential between the conductive structure of the SSF and the current plasma environment.
Masking of aluminum surface against anodizing
NASA Technical Reports Server (NTRS)
Crawford, G. B.; Thompson, R. E.
1969-01-01
Masking material and a thickening agent preserve limited unanodized areas when aluminum surfaces are anodized with chromic acid. For protection of large areas it combines well with a certain self-adhesive plastic tape.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendoza-Moctezuma, A. I.; Aguilar, J. Garcia; Garcia-Garduno, O. A.
Interventional cardiology procedures are an effective alternative for the reestablishment of correct sanguineous circulation in the heart. However, this kind of procedures exposes to the patients to a relatively high radiation doses. Usually, the surface peak skin dose is evaluated using a visual scale with a comparator strip, nevertheless, even if the comparator strip provides a simple and quick method for estimating the dose it has an uncertainty of {+-}25%. For this reason, a better evaluation method is needed. The objective of our project is to determine the surface peak skin dose of interventional cardiology procedures using GafChromic XR-RV2 filmmore » together with a commercial flatbed scanner in reflection mode. Here we report a protocol to handle GafChromic XR-RV2 film using a commercial flat bed scanner in reflection mode aiming at an uncertainty of {+-}3%.« less
Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu
2014-02-01
Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.
21 CFR 178.3290 - Chromic chloride complexes.
Code of Federal Regulations, 2014 CFR
2014-04-01
... square inch of closure area. (b) The packaging container which has its closure area treated with the release agent shall have a capacity of not less than 120 grams of food per square inch of such treated...
Onetti, C M; Gutiérrez, E; Hliba, E; Aguirre, C R
1982-01-01
Synoviorthesis was performed in 217 joints from 111 patients suffering from different stages of rheumatoid arthritis (RA). 32P-colloidal chromic phosphate was employed, with an average dose from 6 mCi for large joints (knees) to 0.3 mCi for small peripheral joints such as average dose from 6 mCi for large joints (knees) to 0.3 mCi for small peripheral joints such as the MCP or PIP joints. Satisfactory clinical results were observed in 84% of the cases and no significant side effects resulted after a follow-up period from 1 to 10 years. Striking effects after treatment were observed through histopathological studies (light and electron microscopy) and the use of contrast arthrography. We concluded that radioactive synovectomy with 32P-chromate is a very useful method for the local treatment of RA.
Hunt, A F; Reed, M I
1990-07-01
The binding mechanisms and binding sites involved in the tannic acid and chromic chloride-induced binding of protein to red cells were investigated using the binding of IgA paraprotein to red cells as model systems. Inhibition studies of these model systems using amino acid homopolymers and compounds (common as red cell membrane constituents) suggest that the mechanisms involved are similar to those proposed for the conversion of hide or skin collagen to leather, as in commercial tanning. These studies also suggest that tannic acid-induced binding of IgA paraprotein to red cells involves the amino acid residues of L-arginine, L-lysine, L-histidine, and L-proline analogous to tanning with phenolic plant extracts. The amino acid residues of L-aspartate, L-glutamate and L-asparagine are involved in a similar manner in chronic chloride-induced binding of protein to red cells.
An Industrial Dental-Erosion by Chromic Acid: A Case Report
Dülgergil, Ç. Türksel; Erdemir, Ebru Olgun; Ercan, Ertuḡrul; Erdemir, Ali
2007-01-01
A case of uncommon occupational dental erosion was reported in an individual who had worked in the war industry for twenty years. This occupation involved daily, at least 8 hours, inhalation of chromic acid being used for cleaning of barrel of cannons. The erosion manifested as dental sensitivity with excessive cervical erosion even with pulpal exposure in certain teeth. Moreover, due to the adverse effect of the chemical against to gingival and/or periodontal tissues, the lesions were extremely harmful with respect to the exposed root-cementum. After proper periodontal therapy, cervical lesions were treated conservatively with a compomer based restorative material without cavity preparation. Although today it is not common due to the well-controlled working conditions, occupational combined dental and medical problems via airborne fumes and/or elements can be seen at workers in chemical factories. A cumulative biohazardous effect is generally seen as not only medical but also dental disorders. PMID:19212488
NASA Astrophysics Data System (ADS)
Nur, K. U.; Adams, L.; Stone, D.; Savva, N.; Adams, M.
2018-03-01
A comparative research using three inert markers, chromic oxide, yttrium and ytterbium to measure the apparent nutrient digestibility of experimental feed in juvenile Hybrid abalone (Haliotis rubra X H. laevigata) and Greenlip abalone (H.laevigata) revealed that apparent digestibility of crude protein (ADCP) measured using yttrium and ytterbium in hybrid abalone were significantly different across the treatments. Protein digestibility measured in experimental tanks was higher than those measured in indoor and outdoor commercial tanks, regardless of inert marker used. Chromic oxide led to overestimated ADCP compared to when measured using yttrium and ytterbium. There were no significant interactions between temperature and inert markers when measuring ADCP and apparent digestibility of gross energy (ADGE). However, there was a significant difference of ADCP amongst inert markers when measured in greenlip abalone cultured at two temperatures. While measurements of ADge calculated using three inert markers shared the same value.
Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori
2015-01-01
In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.
Stefanidis, Dimitrios; Hope, William W; Scott, Daniel J
2011-07-01
The value of robotic assistance for intracorporeal suturing is not well defined. We compared robotic suturing with laparoscopic suturing on the FLS model with a large cohort of surgeons. Attendees (n=117) at the SAGES 2006 Learning Center robotic station placed intracorporeal sutures on the FLS box-trainer model using conventional laparoscopic instruments and the da Vinci® robot. Participant performance was recorded using a validated objective scoring system, and a questionnaire regarding demographics, task workload, and suturing modality preference was completed. Construct validity for both tasks was assessed by comparing the performance scores of subjects with various levels of experience. A validated questionnaire was used for workload measurement. Of the participants, 84% had prior laparoscopic and 10% prior robotic suturing experience. Within the allotted time, 83% of participants completed the suturing task laparoscopically and 72% with the robot. Construct validity was demonstrated for both simulated tasks according to the participants' advanced laparoscopic experience, laparoscopic suturing experience, and self-reported laparoscopic suturing ability (p<0.001 for all) and according to prior robotic experience, robotic suturing experience, and self-reported robotic suturing ability (p<0.001 for all), respectively. While participants achieved higher suturing scores with standard laparoscopy compared with the robot (84±75 vs. 56±63, respectively; p<0.001), they found the laparoscopic task more physically demanding (NASA score 13±5 vs. 10±5, respectively; p<0.001) and favored the robot as their method of choice for intracorporeal suturing (62 vs. 38%, respectively; p<0.01). Construct validity was demonstrated for robotic suturing on the FLS model. Suturing scores were higher using standard laparoscopy likely as a result of the participants' greater experience with laparoscopic suturing versus robotic suturing. Robotic assistance decreases the physical demand of intracorporeal suturing compared with conventional laparoscopy and, in this study, was the preferred suturing method by most surgeons. Curricula for robotic suturing training need to be developed.
The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.
Van Meter, W
1996-01-01
PURPOSE: Post operative adjustment of a single continuous suture is an effective means of reducing post keratoplasty astigmatism. This study evaluates post keratoplasty keratometry following suture adjustment with an adjusted suture in place and after the suture is removed. METHODS: Average keratometric astigmatism was measured over 24 months time in 26 patients with an adjusted continuous suture and 24 patients with a continuous suture that was not adjusted. Average keratometry in 43 patients with an adjusted continuous suture was compared with 37 patients with combined continuous and interrupted sutures. Finally, suture out astigmatism in 19 adjusted patients was compared to six patients with no adjustment. RESULTS: There was an increase in average corneal astigmatism over two years of 2.2 diopters in the adjusted group and 1.7 diopters in the non-adjusted group with sutures in place. One year following surgery, average keratometry flattened from 47.5 to 42.9 diopters in the adjusted continuous group and from 47.0 to 46.0 diopters in the group with combined continuous and interrupted sutures. Following suture removal, average astigmatism in patients who had suture adjustment was 4.4 diopters +/- 2.5 diopters (range 1-10 diopters), and 6.01 diopters (range 4-7) in the non-adjusted group. CONCLUSIONS: Average post keratoplasty astigmatism increases after a continuous suture is adjusted but the increase is comparable to patients with acceptable astigmatism who do not require adjustment. More progressive corneal flattening over 12 months time is seen with a continuous suture than which combined sutures. Average suture out astigmatism was 4.0 diopters following suture adjustment, compared to an average of 8.4 diopters prior to adjustment. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 7A FIGURE 7B PMID:8981721
Malignant diseases of hematopoietic and lymphoid tissues in Chernobyl clean-up workers.
Gluzman, Daniel; Imamura, Nobutaka; Sklyarenko, Lylia; Nadgornaya, Valentina; Zavelevich, Michael; Machilo, Vasily
2005-01-01
The question as to whether the incidence of leukemias and malignant lymphomas among the clean-up workers increased in 18 years after the catastrophe is still a point of much controversy. Precise diagnosis of the main forms of hematopoietic malignancies and comparison of these data with those in the general population will be helpful in estimating thr relative contribution of the radiation factor to the overall incidence of such pathologies. In all, 187 consecutive cases of malignant diseases of hematopoietic and lymphoid tissues in Chernobyl clean-up workers were analyzed in Ukrainian Reference Laboratory in 1996-2003. A total of 1942 consecutive patients of general population, mainly the residents of Kyiv city and district, diagnosed in References Laboratory at the same period comprised the group of comparison. The morphology and cytochemistry of bone marrow and peripheral blood cells were studied. Immunocytochemical techniques (PAP, APAAP, ABC) and the panel of monoclonal antibodies to differentiation antigens of leukocytes were employed for immunophenotyping leukemic cells. Various types of malignant disease of hematopoietic and lymphoid tissues were registered in Chernobyl clean-up workers under study including myelodysplastic syndromes (nine patients), acute lymphoblastic leukemia (eight) and acute myeloblastic leukemia (31), chromic myeloid leukemia (17), multiple myeloma (17) and other forms of chromic myeloproliferative and lymphoproliferative disease including B-cell chromic lymphocytic leukemia (49 patients). The verified diagnosis of tumors of hematopoietic malignancies according to modern classification (EGIL, WHO) could be the prerequisite for further analytical epidemiology study of leukemias that may be related to the Chernobyl accident.
NASA Technical Reports Server (NTRS)
Shogrin, Bradley A.; Jones, William R., Jr.; Herrera-Fierro, Pilar
1997-01-01
The boundary-lubrication performance of perfluoropolyether (PFPE) thin films in the presence of passivated 440 C stainless steel is presented. The study utilized a standard ball-on-disc tribometer. Stainless steel surfaces were passivated with one of four techniques: 1) submersion in a chromic acid bath for 30 minutes at 46 C, 2) submersion in a chromic acid bath for 60 minutes at 56 C, 3) submersion in a tricresyl phosphate (TCP) bath for 2 days at 107 C, or 4) UV/Ozone treated for 15 minutes. After passivation, each disc had a 400 A film of PFPE (hexafluoropropene oxide) applied to it reproducibly (+/- 20%) and uniformly (+/- 15%) using a film deposition device. The lifetimes of these films were quantified by measuring the number of sliding wear cycles required to induce an increase in the friction coefficient from an initial value characteristic of the lubricated wear couple to a final, or failure value, characteristic of an unlubricated, unpassivated wear couple. The lubricated lifetime of the 440 C couple was not altered as a result of the various passivation techniques. The resulting surface chemistry of each passivation technique was examined using X-ray Photoelectron Spectroscopy (XPS). It was found that chromic acid passivation altered the Cr to Fe ratio of the surface. TCP passivation resulted in a FePO4 layer on the surface, while UV/Ozone passivation only removed the carbonaceous contamination layer. None of the passivation techniques were found to dramatically increase the oxide film thickness.
Suture Coding: A Novel Educational Guide for Suture Patterns.
Gaber, Mohamed; Abdel-Wahed, Ramadan
2015-01-01
This study aims to provide a helpful guide to perform tissue suturing successfully using suture coding-a method for identification of suture patterns and techniques by giving full information about the method of application of each pattern using numbers and symbols. Suture coding helps construct an infrastructure for surgical suture science. It facilitates the easy understanding and learning of suturing techniques and patterns as well as detects the relationship between the different patterns. Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. The arrangement is fixed as 1-3-5-7 and a-c-e-g on one side (whether right or left) and as 2-4-6-8 and b-d-f-h on the other side. Needle placement must start from number 1 or letter "a" and continue to follow the code till the end of the stitching. Some rules are created to be adopted for the application of suture coding. A suture trainer containing guide points that simulate the coding process is used to facilitate the learning of the coding method. (120) Is the code of simple interrupted suture pattern; (ab210) is the code of vertical mattress suture pattern, and (013465)²/3 is the code of Cushing suture pattern. (0A1) Is suggested as a surgical suture language that gives the name and type of the suture pattern used to facilitate its identification. All suture patterns known in the world should start with (0), (A), or (1). There is a relationship between 2 or more surgical patterns according to their codes. It can be concluded that every suture pattern has its own code that helps in the identification of its type, structure, and method of application. Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. Coding methods facilitate suture patterns learning process. The use of suture coding can be a good approach to the construction of an infrastructure of surgical suture science and the facilitation of the understanding and learning of suture pattern techniques. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.
Chiu-Tsao, S; Massillon-Jl, G; Domingo-Muñoz, I; Chan, M
2012-06-01
To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams were calibrated per AAPM TG-51 protocol while the kilovoltage beam was calibrated following the TG-61 using an ionization chamber calibrated at NIST. Each film piece was scanned three consecutive times in the center of Epson 10000XL flatbed scanner in transmission mode, landscape orientation, 48-bit color at two separate spatial resolutions of 75 and 300 dpi. The data were analyzed using ImageJ and, for each scanned image, a region of interest (ROI) of 2×2cm 2 at the field center was selected to obtain the mean pixel value with its standard deviation in the ROI. For each energy, dose value and spatial resolution, the average netOD and its associated uncertainty were determined. The Student's t-test was performed to evaluate the statistical differences between the netOD/dose values of the three energy modalities, with different color channels and spatial resolutions. The dose response curves for the three energy modalities were compared in three color channels with 75 and 300dpi. Weak energy dependence was found. For doses above 100cGy, no statistical differences were observed between 6 and 15MV beams, regardless of spatial resolution. However, statistical differences were observed between 50kV and the megavoltage beams. The degree of energy dependence (from MV to 50kV) was found to be function of color channel, dose level and spatial resolution. The dose response curves for GafChromic EBT3 films were found to be weakly dependent on the energy of the photon beams from 6MV to 50kV. The degree of energy dependence varies with color channel, dose and spatial resolution. GafChromic EBT3 films were supplied by Ashland Corp. This work was partially supported by DGAPA-UNAM grant IN102610 and Conacyt Mexico grant 127409. © 2012 American Association of Physicists in Medicine.
Comparison of the cheese-wiring effects among three sutures used in rotator cuff repair
Lambrechts, Mark; Nazari, Behrooz; Dini, Arash; O'Brien, Michael J.; Heard, Wendell M. R.; Savoie, Felix H.; You, Zongbing
2014-01-01
Purpose: The goal of this study was to compare the cheese-wiring effects of three sutures with different coefficients of friction. Materials and Methods: Sixteen human cadaveric shoulders were dissected to expose the distal supraspinatus and infraspinatus muscle tendons. Three sutures were stitched through the tendons: #2 Orthocord™ suture (reference #223114, DePuy Mitek, Inc., Raynham, MA), #2 ETHIBOND* EXCEL Suture, and #2 FiberWire® suture (FiberWire®, Arthrex, Naples, FL). The sutures were pulled by cyclic axial forces from 10 to 70 N at 1 Hz for 1000 cycles through a MTS machine. The cut-through distance on the tendon was measured with a digital caliper. Results: The cut-through distance in the supraspinatus tendons (mean ± standard deviation, n = 12) were 2.9 ± 0.6 mm for #2 Orthocord™ suture, 3.2 ± 1.2 mm for #2 ETHIBOND* suture, and 4.2 ± 1.7 mm for #2 FiberWire® suture. The differences were statistically significant analyzing with analysis of variance (P = 0.047) and two-tailed Student's t-test, which showed significance between Orthocord™ and FiberWire® sutures (P = 0.026), but not significant between Orthocord™ and ETHIBOND* sutures (P = 0.607) or between ETHIBOND* and FiberWire® sutures (P = 0.103). Conclusion: The cheese-wiring effect is less in the Orthocord™ suture than in the FiberWire® suture in human cadaveric supraspinatus tendons. Clinical Relevance: Identification of sutures that cause high levels of tendon cheese-wiring after rotator cuff repair can lead to better suture selection. PMID:25258499
Wound infection prophylaxis in pediatric acute appendicitis: a 26-year prospective study.
Ein, Sigmund H; Sandler, Anthony
2006-03-01
The purpose of this study was to determine the best wound infection prophylaxis in pediatric acute appendicitis. From 1969 to 1995 inclusive, 453 consecutive pediatric patients at the same children's hospital had an appendix with acute inflammation (acute appendicitis) removed by the same staff surgeon and his resident. The stump was not inverted, and chromic catgut was used throughout. No intraperitoneal antibiotics, irrigation, or drains were used, and the skin closure was with silk sutures initially and then with staples since 1986. The infants and children were divided into 6 consecutive groups of 52 to 96 patients, with each group lasting 2 to 5 years. The wound treatment groups were as follows: no treatment, drain or pack, drain or pack plus antibiotic powder, antibiotic powder, preoperative intravenous antibiotic plus antibiotic powder, and preoperative intravenous antibiotic. The wound Penrose drain, one half-inch gauze pack, and/or antibiotic powder (ampicillin, 1977-1981; cefoxitin, 1982-1995) were all placed in the subcutaneous space. There were a total of 50 (11%) wound infections (pus) that occurred between 4 and 40 days when no antibiotic powder was used and 2 to 14 days with antibiotic powder. In all 6 groups of patients, no organism was grown in most (80%) infections and Escherichia coli was the second commonest (12%). The serous ooze, which occurred only with the use of antibiotic powder (8%), was seen between 6 and 18 days, and no organism was ever cultured. The patients with preoperative (or intraoperative) intravenous antibiotics (cefoxitin) plus wound antibiotic powder (cefoxitin) had the lowest infection rate (2.5%). When this group was compared with the baseline group 1 (no treatment), it was the only group in which wound treatment made a significant difference (P = .003).
Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W
1996-01-01
Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.
Comparison between suture anchor and transosseous suture for the modified-Broström procedure.
Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin
2012-06-01
This prospective, randomized study was conducted to compare clinical outcomes of the modified Broström procedure using suture anchor or transosseous suture technique for chronic ankle instability. Forty patients were followed for more than 2 years after modified Broström procedure. Twenty procedures using a suture anchor and 20 procedures using a transosseous suture were performed by one surgeon. The clinical evaluation consisted of the Karlsson scale and the Sefton grading system. Talar tilt and anterior talar translation were measured on anterior and varus stress radiographs. The Karlsson scale had improved significantly to 90.8 points in the suture anchor group, and to 89.2 points in the transosseous suture group. According to Sefton grading system, 18 patients (90%) in suture anchor group and 17 patients (85%) in transosseous suture group achieved satisfactory results. The talar tilt angle and anterior talar translation improved significantly to 5.9 degrees and 4.2 mm in suture anchor group, and to 5.4 degrees and 4.1 mm in transosseous suture group, respectively. No significant differences existed in clinical and functional outcomes between the two techniques for ligament reattachment. Both modified Broström procedures using the suture anchor and transosseous suture seem to be effective treatment methods for chronic lateral ankle instability.
40 CFR 63.341 - Definitions and nomenclature.
Code of Federal Regulations, 2010 CFR
2010-07-01
... electrical insulation) using a chromic acid solution. In chromium anodizing, the part to be anodized acts as... chromium anodizing: rectifiers fitted with controls to allow for voltage adjustments, heat exchanger... electroplating: Rectifiers, anodes, heat exchanger equipment, circulation pumps, and air agitation systems...
SURFACE TREATMENT OF MOLYBDENUM METAL
Coffer, C.O.
1961-12-01
A process of descaling molybdenum articles comprises first immersing them in an aqueous sodium hydroxide-potassium permanganate solution of between 60 and 85 deg C, rinsing, and then immersing them in an aqueous solution containing a mixture of sulfuric, hydrochloric, and chromic acids.
An original use in low colo-rectal anastomosis of the new surgical device "grasping tie".
Picardi, Nicola
2005-01-01
The grasping tie is an original and mechanical tool, conceived and planned to be used in digestive surgery to do the equivalent of a purse string. Its use is conceived to make easier the mechanical anastomosis in the more difficult situations as the oesophago-jejunal or the very low colo-rectal ones, as in the example of the presented paper. A thin ribbon of nylon will be progressively tightened as a one-way running knot upon the tract of the gut, either directly or about the axis of a circular stapler. Once completed the stapler suture it will be completely extracted together with the muscle-mucosal rings, so that nothing of the ribbon remains in the patient. The use of the grasping tie is also advantageous in quickly closing the gut above and below a tumour, to a safer manipulation and to reduce the contamination of the operative field. An original and useful use of the grasping tie is demonstrated in the present paper for the surgical treatment of a low rectal cancer with preservation of the anus. Its use is that to close the distal stump of the rectum below the tumour, to take away from the pelvis the proximal stump with the tumour, and then to proceed to the mechanical anastomosis in a now wide operatory field, introducing in the anus an enteral dilator and preparing on it the definitive purse string, as illustrated.
Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.
2016-01-01
Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535. PMID:27357383
Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y
2016-06-01
This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269-275. DOI: 10.1302/2046-3758.56.2000535. © 2016 Lo et al.
Hennecke, Kathleen; Redeker, Joern; Kuhbier, Joern W.; Strauss, Sarah; Allmeling, Christina; Kasper, Cornelia; Reimers, Kerstin; Vogt, Peter M.
2013-01-01
Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. PMID:23613793
Liu, Sean Shih-Yao; Xu, Haisong; Sun, Jun; Kontogiorgos, Elias; Whittington, Patrick R; Misner, Kenner G; Kyung, Hee-Moon; Buschang, Peter H; Opperman, Lynne A
2013-08-01
Suture expansion stimulates bone growth to correct craniofacial deficiencies but has a high potential of treatment relapse. The objective of this study was to investigate whether there is a dose-dependent relationship between the recombinant human bone morphogenetic protein-2 (rhBMP-2) and bone formation during suture expansion. Fifty 6-week-old male New Zealand white rabbits were randomly assigned to 5 groups to receive 0 (control), 0.01, 0.025, 0.1, or 0.4 mg/mL of rhBMP-2 delivered by absorbable collagen sponge placed over the interfrontal suture. The suture was expanded for 33 days by 200 g of constant force via a spring anchored with 2 miniscrew implants. Distance of suture expansion, suture volume, and cross-sectional area after expansion were measured using radiographs with bone markers and microcomputed tomography. Suture widths and mineralization appositional rates were calculated based on the widths between bone labels under an epifluorescent microscope. Software (Multilevel Win 2.0; University of Bristol, Bristol, United Kingdom) was used to model distance of suture expansion over time as polynomials to compare group differences. Wilcoxon signed rank tests were performed to compare the suture volume and cross-sectional area, mineral apposition rate, and suture width between groups. The significance level was set at P = 0.05. Whereas the sutures were expanded in all groups, sutures were expanded by significantly greater amounts in the control and the 0.01 mg/mL groups without fusing the sutures than in the 0.025, 0.1, and 0.4 mg/mL groups with fusing sutures. Compared with the controls, the 0.01 mg/mL group showed significantly lower suture volumes, cross-sectional areas, and suture widths after expansion. The mineral apposition rate was significantly higher in the 0.01 mg/mL group than in the controls from days 10 to 30. The 0.01 mg/mL dose of rhBMP-2 delivered by absorbable collagen sponge can stimulate bone formation at the bony edges of the suture during suture expansion; however, higher concentrations cause suture fusion. With an appropriate concentration, rhBMP-2 might facilitate suture expansion for clinical uses. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cameron, Bruce D.; Joos, Karen M.; Shen, Jin-Hui
1996-05-01
Purpose: To develop a simple suture lysis technique for post-trabeculectomy examinations under anesthesia since slit lamp laser suture lysis in the clinic cannot be performed on infants and young children. Methods: An argon endolaser probe lysed 10-0 nylon suture through conjunctiva harvested from human cadaver eyes. Since suture lysis failed with the thick Hoskins lens, clear plastic from the suture package compressed the conjunctiva. The conjunctiva was examined histologically. Results: Argon laser suture lysis (250 mW, 0.1 sec, 488 - 514 nm) was achieved without conjunctival damage. Conclusion: The argon endolaser probe is effective for suture lysis when the slit lamp cannot be used.
Liu, Lei; Jiang, Yunyao; Boyce, Mary; Ortiz, Christine; Baur, Jeffery; Song, Juha; Li, Yaning
2017-06-14
Irregular interdigitated morphology is prevalent in biological sutures in nature. Suture complexity index has long been recognized as the most important morphological parameter to govern the mechanical properties of biological sutures. However, the suture complexity index alone does not reflect all aspects of suture morphology. The goal of this investigation was to determine that besides suture complexity index, whether the degree of morphological irregularity of biological sutures has influences on the mechanical properties, and if there is any, how to quantify these influences. To explore these issues, theoretical and finite element (FE) suture models with the same suture complexity index but different levels of morphological irregularity were developed. The quasi-static stiffness, strength for damage initiation and post-failure process of irregular sutures were studied. It was shown that for the same suture complexity index, when the level of morphological irregularity increases, the overall strain to failure will increase while tensile stiffness is retained; also, the total energy to fracture increases with a sacrifice in strength to damage initiation. These results reveal that morphological irregularity is another important independent parameter to govern and balance the mechanical properties of biological sutures. Therefore, from the mechanics point of view, the prevalence of irregular suture morphology in nature is a merit, not a defect. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wongkietkachorn, Apinut; Rhunsiri, Peera; Boonyawong, Pangpoom; Lawanprasert, Attaporn; Tantiphlachiva, Kasaya
2016-01-01
Tutoring in suturing was developed to compensate for a shortage of suturing cases. The objective of this study was to compare ideal suturing score (ISS; 9 points), suturing time (min:sec), and suture placement error (mm) between medical students completing the suturing tutoring program and medical students attending ordinary medical school training program. Participants consisted of 2 groups of medical students who had never performed suturing. The study group had the role of suturing tutor to teach interested high school students. The control group consisted of volunteers from the ordinary medical school program. Skills measurement was performed by having students from both the groups perform 3 vertical mattress sutures on a model. The study group was tested at weeks 1, 9, and 10 to assess improvement. Both the groups were tested at week 10 to compare final learning outcome. There were 41 and 40 participants in the study group and the control group, respectively. ISS was significantly improved in the study group from week 1-week 10 (7.0 ± 1.3 vs. 8.2 ± 0.9, p = 0.01). At week 10, the study group had a higher mean ISS than the control group (8.2 ± 0.9 vs. 7.8 ± 1.1, p = 0.68). Mean suturing time and mean placement error were also lower in the study group at the end of suturing training (5:1 ± 1:0 vs. 5:2 ± 1:2, p = 0.13; 7.4 ± 7.4 vs. 8.0 ± 10.8, p = 0.44). Tutoring trainees to suture can improve a student's ability to learn how to suture. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred
2011-03-01
Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.
Study of insertion force and deformation for suturing with precurved NiTi guidewire.
Wang, Yancheng; Chen, Roland K; Tai, Bruce L; Xu, Kai; Shih, Albert J
2015-04-01
This research presents an experimental study evaluating stomach suturing using a precurved nickel-titanium (NiTi) guidewire for an endoscopic minimally invasive obesity treatment. Precise path planning is critical for accurate and effective suturing. A position measurement system utilizing a hand-held magnetic sensor was used to measure the shape of a precurved guidewire and to determine the radius of curvature before and after suturing. Ex vivo stomach suturing experiments using four different guidewire tip designs varying the radius of curvature and bevel angles were conducted. The changes in radius of curvature and suturing force during suturing were measured. A model was developed to predict the guidewire radius of curvature based on the measured suturing force. Results show that a small bevel angle and a large radius of curvature reduce the suturing force and the combination of small bevel angle and small radius of curvature can maintain the shape of guidewire for accurate suturing.
The history and evolution of sutures in pelvic surgery
Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D
2011-01-01
Summary The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool. PMID:21357979
The history and evolution of sutures in pelvic surgery.
Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D
2011-03-01
The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool.
Aortic perforation sustained at laparoscopy.
Lynn, S C; Katz, A R; Ross, P J
1982-04-01
A major type of complication associated with laparoscopic sterilization has been overcome by changing from electrocautery to either the Hulka clip or silicone rubber band technique, but major puncture and laceration injuries continue at the rate of 0.5% to 2%. The only case of major vascular injury incurred in over 4000 laparoscopic sterilization procedures performed from 1974 through 1980 at the Hermann Hospital in Houston, Texas is reported. A 40-year-old white female, para 3-0-1-3, was admitted for a laparoscopic sterilization procedure. The physical examination was within normal limits. The procedure was carried out by insufflating the peritoneal cavity with 2 liters of CO2 through a 12-cm Verres needle placed subumbilically while testing the abdomen with towel clips. Insufflating pressure never rose above 15 mm of mercury, and an adequate pneumoperitoneum was obtained. With the patient in the Trendelenburg position the trocar was inserted and the laparoscope placed with no apparent difficulty. The Falope Ring applicator sleeve was inserted suprapublically under direct vision. After placing the rings bilaterally, the cul-de-sac was noted to contain approximately 300 cc of blood. This was aspirated, but blood slowly reaccumulated in the cul-de-sac. Laparoscopic examination provided inadequate visualization of the posterior surface of the mesosalpinges, and it was decided to perform laparotomy. Upon opening the abdomen, the pulse rose from 85 to 110 per minute and the blood pressure fell from 90/60 to 50/0 mm HG. Rapid infusion of isotonic crystalloid and 3 units of packed red blood cells restored the patient's vital signs to normal. Examination of the abdominal wall and pelvic organs was normal, but a retroperitoneal hematoma was discovered in the area of the sacral promontroy. The posterior peritoneum was opened, and a 13 x 15-cm hematoma was evacuated. A 3-mm puncture wound was noted in the anterior wall of the aorta 3 cm cephalad to the bifurcation. The square defect was isolated with vascular clamps and repaired with a single layer of simple interrupted Prolene sutures. Abdominal exploration revealed a 3-mm defect in the small bowel mesentery that was repaired with interrupted chromic sutures, and the abdomen was closed. This report illustrates the perpetual caution that must be exercised in the performance of a routine gynecologic procedure. The blind puncture of the abdominal wall with the Verres needle and the laparoscope trocar must be performed with great care.
Suture Products and Techniques: What to Use, Where, and Why.
Regula, Christie G; Yag-Howard, Cyndi
2015-10-01
There are an increasing number of wound closure materials and suturing techniques described in the dermatologic and surgery literature. A dermatologic surgeon's familiarity with these materials and techniques is important to supplement his or her already established practices and improve surgical outcomes. To perform a thorough literature review of wound closure materials (sutures, tissue adhesives, surgical tape, and staples) and suturing techniques and to outline how and when to use them. A literature review was conducted using PubMed and other online search engines. Keywords searched included suture, tissue adhesive, tissue glue, surgical tape, staples, dermatologic suturing, and suturing techniques. Numerous articles outline the utility of various sutures, surgical adhesives, surgical tape, and staples in dermatologic surgery. In addition, there are various articles describing classic and novel suturing techniques along with their specific uses in cutaneous surgery. Numerous factors must be considered when choosing a wound closure material and suturing technique. These include wound tension, desire for wound edge eversion/inversion, desired hemostasis, repair type, patient's ability to care for the wound and return for suture removal, skin integrity, and wound location. Careful consideration of these factors and proper execution of suturing techniques can lead to excellent cosmetic results.
Soil-strain compatibility: the key to effective use of arbuscular mycorrhizal inoculants?
Herrera-Peraza, Ricardo A; Hamel, Chantal; Fernández, Félix; Ferrer, Roberto L; Furrazola, Eduardo
2011-04-01
Consistency of response to arbuscular mycorrhizal (AM) inoculation is required for efficient use of AM fungi in plant production. Here, we found that the response triggered in plants by an AM strain depends on the properties of the soil where it is introduced. Two data sets from 130 different experiments assessing the outcome of a total of 548 replicated single inoculation trials conducted either in soils with a history of (1) high input agriculture (HIA; 343 replicated trials) or (2) in more pristine soils from coffee plantations (CA; 205 replicated trials) were examined. Plant response to inoculation with different AM strains in CA soils planted with coffee was related to soil properties associated with soil types. The strains Glomus fasciculatum-like and Glomus etunicatum-like were particularly performant in soil relatively rich in nutrients and organic matter. Paraglomus occultum and Glomus mosseae-like performed best in relatively poor soils, and G. mosseae and Glomus manihotis did best in soils of medium fertility. Acaulospora scrobiculata, Diversispora spurca, G. mosseae-like, G. mosseae and P. occultum stimulated coffee growth best in Chromic, Eutric Alluvial Cambisol, G. fasciculatum-like and G. etunicatum-like in Calcaric Cambisol and G. manihotis, in Chromic, Eutric Cambisols. Acaulospora scrobiculata and Diversispora spurca strains performed best in Chromic Alisols and Rodic Ferralsols. There was no significant relationship between plant response to AM fungal strains and soil properties in the HIA soil data set, may be due to variation induced by the use of different host plant species and to modification of soil properties by a history of intensive production. Consideration of the performance of AM fungal strains in target soil environments may well be the key for efficient management of the AM symbiosis in plant production.
Storch, Mark; Scalzo, Howard; Van Lue, Stephen; Jacinto, Gabriel
2002-01-01
The goal of this study was to compare the physical and functional properties of coated polyglactin 910 suture with and without triclosan by human assessment and instrument-based measurements. Surgeons specializing in general, orthopedic, plastic, or gynecologic surgery evaluated the suture materials in an in vivo porcine model with regard to (1) ease of passage through tissue, (2) first-throw knot holding, (3) knot tie-down smoothness, (4) knot security, (5) surgical handling, and (6) overall evaluation. Breaking strength retention was determined at 14, 21, 28, and 35 days post-implantation in rats using a tensile strength measurement device. The absorption rate was determined in rats by histopathology at 7, 28, 56, 63, 70, and 77 days post-implantation. The tactile smoothness and tie-down behavior of both wet and dry sutures were evaluated by product characterization technicians. The scores for surgeons' evaluation of suture material were favorable and similar for both sutures. Surgeons could not reliably make a distinction in handling between the two sutures. Breaking strength retention was the same for both sutures, ranging from 79% on day 14 to 5% on day 35. Both sutures were essentially absorbed at 70 days post-implantation. Product characterization assessment of the two sutures found them to be indistinguishable. The addition of triclosan to coated polyglactin 910 sutures did not affect physical handling properties or performance characteristics based on the testing and evaluations performed.
Takeuchi, Masaki
2013-01-01
Background: This study describes the use of a bioabsorbable suture for skin suturing during surgery for lateral ray polydactyly followed by favorable postoperative outcome without the need for postoperative suture removal. Methods: A 5-0 Vicryl Rapide suture was used for skin suturing during surgery for lateral ray polydactyly in 9 children (mean age, 12.4 mo). Children were allowed to walk and bathe 2 weeks after surgery when over-the-suture taping therapy was started. Results: In all cases, the Vicryl Rapide suture disappeared completely within 3 weeks of surgery, and no removal of residual suture was required. No postoperative complications, such as suture abscess, wound dehiscence, or ulcer, were observed. During a mean 24-month postoperative follow-up, no elevation of the interdigital space due to hypertrophic scarring or scar contracture was observed, and no revision surgery was required. Conclusions: Although the breaking strength of Vicryl Rapide declines within the first 10 days after surgery, this property will unlikely lead to postoperative wound dehiscence due to a relatively light load being applied to the lateral toes. The use of a bioabsorbable suture for skin suturing during surgery for lateral lay polydactyly is highly beneficial as it eliminates pain caused by suture removal and the risk of tissue damage while reducing the burden on medical staff. PMID:25289236
Song, Dongzhe; Zhang, Fugui; Reid, Russell R; Ye, Jixing; Wei, Qiang; Liao, Junyi; Zou, Yulong; Fan, Jiaming; Ma, Chao; Hu, Xue; Qu, Xiangyang; Chen, Liqun; Li, Li; Yu, Yichun; Yu, Xinyi; Zhang, Zhicai; Zhao, Chen; Zeng, Zongyue; Zhang, Ruyi; Yan, Shujuan; Wu, Tingting; Wu, Xingye; Shu, Yi; Lei, Jiayan; Li, Yasha; Zhang, Wenwen; Wang, Jia; Lee, Michael J; Wolf, Jennifer Moriatis; Huang, Dingming; He, Tong-Chuan
2017-11-01
The cranial suture complex is a heterogeneous tissue consisting of osteogenic progenitor cells and mesenchymal stem cells (MSCs) from bone marrow and suture mesenchyme. The fusion of cranial sutures is a highly coordinated and tightly regulated process during development. Craniosynostosis is a congenital malformation caused by premature fusion of cranial sutures. While the progenitor cells derived from the cranial suture complex should prove valuable for studying the molecular mechanisms underlying suture development and pathogenic premature suture fusion, primary human cranial suture progenitors (SuPs) have limited life span and gradually lose osteoblastic ability over passages. To overcome technical challenges in maintaining sufficient and long-term culture of SuPs for suture biology studies, we establish and characterize the reversibly immortalized human cranial suture progenitors (iSuPs). Using a reversible immortalization system expressing SV40 T flanked with FRT sites, we demonstrate that primary human suture progenitor cells derived from the patent sutures of craniosynostosis patients can be efficiently immortalized. The iSuPs maintain long-term proliferative activity, express most of the consensus MSC markers and can differentiate into osteogenic and adipogenic lineages upon BMP9 stimulation in vitro and in vivo. The removal of SV40 T antigen by FLP recombinase results in a decrease in cell proliferation and an increase in the endogenous osteogenic and adipogenic capability in the iSuPs. Therefore, the iSuPs should be a valuable resource to study suture development, intramembranous ossification and the pathogenesis of craniosynostosis, as well as to explore cranial bone tissue engineering. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Catalyst surfaces for the chromous/chromic redox couple
NASA Technical Reports Server (NTRS)
Giner, J. D.; Cahill, K. J. (Inventor)
1980-01-01
An electricity producing cell of the reduction-oxidation (REDOX) type is described. The cell is divided into two compartments by a membrane, each compartment containing a solid inert electrode. A ferrous/ferric couple in a chloride solution serves as a cathode fluid which is circulated through one of the compartments to produce a positive electric potential disposed therein. A chromic/chromous couple in a chloride solution serves as an anode fluid which is circulated through the second compartment to produce a negative potential on an electrode disposed therein. The electrode is an electrically conductive, inert material plated with copper, silver or gold. A thin layer of lead plates onto the copper, silver or gold layer when the cell is being charged, the lead ions being available from lead chloride which was added to the anode fluid. If the REDOX cell is then discharged, the current flows between the electrodes causing the lead to deplate from the negative electrode and the metal coating on the electrode will act as a catalyst to cause increased current density.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soper, J.T.; Berchuck, A.; Clarke-Pearson, D.L.
1991-08-15
Forty-nine women with apparent Stage 1 and 2 ovarian carcinoma received intraperitoneal phosphate 32 as the only adjuvant therapy after primary surgery. In addition to bilateral salpingo-oophorectomy, 40 (82%) had analysis of peritoneal cytology, and 35 (71%) underwent omentectomy. Random peritoneal biopsies and retroperitoneal lymph node sampling were not done in any of these patients. The overall and disease-free survival rates were 86% and 75%, respectively, with no significant differences by stage, histologic grade, histologic type, or low-risk versus high-risk subsets recognized in patients who received comprehensive surgical staging. Seven (58%) of 12 patients had lymph node metastasis as themore » first site of recurrence, including two of three with late recurrences. Significant morbidity related to intraperitoneal chromic phosphate (32P) occurred in one (2%) woman. These results emphasize the need for comprehensive surgical staging of women with apparent early ovarian carcinoma to aid in the selection of appropriate initial adjuvant therapy.« less
Food irradiation dosimetry by opti-chromic technique
NASA Astrophysics Data System (ADS)
Zhan-Jun, Liu; Radak, B. B.; McLaughlin, W. L.
The measurement of gamma-radiation quantities, e.g., absorbed dose in materials such as water, plastics, foodstuffs, is a convenient means of quality assurance in radiation processing. A new dosimetry system, called the "Opti-Chromic" dosimeter, is commercially available in large batches for use as a routine measurement system in the absorbed dose range 10 to 2x10 4 Gy. This dose range covers most food irradiation applications. A statistical evaluation was made of the reproducibility of this dosimeter for measuring doses appropriate for the disinfestation and shelf-life extension of many foods, namely 10 to 2x10 3 Gy. In addition, the small dosimeters were used to map absorbed dose distributions in boxes of foods having four different bulk densities (grapefruit, lemons, peanuts, and wheat bran). It is demonstrated that the dosimeters are rugged and stable enough to be used over a wide temperature and humidity range, and, in fact, can be placed in such environments as the inside of citrus fruits without adverse effects on their ability to give satisfactory dose assessment.
Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming
2014-01-01
Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.
Zorn, Kevin C; Trinh, Quoc-Dien; Jeldres, Claudio; Schmitges, Jan; Widmer, Hugues; Lattouf, Jean-Baptiste; Sammon, Jesse; Liberman, Dan; Sun, Maxine; Bianchi, Marco; Karakiewicz, Pierre I; Denis, Ronald; Gautam, Gagan; El-Hakim, Assaad
2012-05-01
Study Type - RCT (randomized trial) Level of Evidence 2b. What's known on the subject? and What does the study add? In a previous randomized controlled trial, barbed polyglyconate suture for vesico-urethral anastomosis was associated with more frequent cystogram leaks, longer mean catheterization times and greater suture costs per case. In the current randomized controlled trial, we show that barbed polyglyconate suture is associated with decreased anastomosis time, decreased need to readjust suture tension, cost reduction, and equal continence and early/late urinary complication rates. To examine the effectiveness of barbed polyglyconate suture (V-Loc 180; Covidien, Mansfield, MA, USA) compared with standard monofilament for posterior reconstruction (PR) and vesico-urethral anastomosis (VUA) during robot-assisted radical prostatectomy (RARP). A prospective randomized controlled trial was conducted in 70 consecutive RARP cases by a single surgeon (K.C.Z.). Standard VUA was performed using three 4-0 poliglecaprone 25 (Monocryl; Ethicon Endosurgery, Cincinnati, OH, USA) sutures secured with absorbable suture clips (LapraTy, Ethicon; one single 6-inch [15.2 cm] for PR and two attached 6-inch [15.2 cm] for VUA). Barbed suture VUA was performed using two 3-0 6-inch (15.2 cm) barbed polyglyconate sutures. Time to complete the suture set-up by the nursing team, anastomosis time and need to adjust suture tension were recorded. Suture-related complications, validated-questionnaire continence and cost were also examined. Compared with a conventional reconstruction technique, there was a significant reduction in mean nurse set-up time (31 vs. 294 s; P < 0.01) and reconstruction time (13.1 vs. 20.8 min; P < 0.01) for the barbed suture technique. Need to readjust suture tension or to place additional suture clips for watertight closure was greater in the standard monofilament group than in the barbed suture group (6% vs. 24%; P= 0.03). • A cost reduction was recorded at our institution (48.05 vs. 70.25 $CAN) with the barbed suture technique. • With a mean follow-up of 6.2 months, no delayed anastomotic leak or bladder neck contracture was observed in either group. • Pad-free continence outcomes for the monofilament suture vs the barbed suture groups at 1 (64 vs. 69%, P= 0.6), 3 (76 vs. 81%, P= 0.5) and 6 months (88 vs. 92%, P= 0.7) were similar. • Compared with standard monofilament suture, the unidirectional barbed polyglyconate suture appears to provide safe, efficient and cost-effective PR and VUA during RARP. • Use of the interlocked barbed polyglyconate suture technique prevents slippage, precluding the need for assistance, knot-tying and constant reassessment of anastomosis integrity. © 2012 THE AUTHORS. BJU INTERNATIONAL © 2012 BJU INTERNATIONAL.
Suture cost savings in the OR.
Walsh, Susanna S
2012-05-01
Materials management personnel at a health care facility in Baltimore, Maryland, were stocking too much suture. They stocked suture requested by surgeons or recommended by suture company representatives, and, because the facility is a teaching institution, they stocked suture requested by residents. No master suture database was available to determine what was needed and what was not. As a result, some suture was rarely used, which cost the facility money and took up inventory space. In response, I created a list of the existing inventory and coordinated with the specialty surgical service coordinators to determine which suture was typically used and in what quantities. I used this information to create a master list, with the goal of eliminating the purchase of suture that was not on this list. I gave the staff members and surgeons two months to assess the list and determine whether the suggested suture was sufficient for their needs. I then asked the materials management personnel to order and maintain suture stock based on the master list. This process took approximately four months and shows how health care providers can take a high-volume item, such as suture, and create cost-saving processes that will serve surgeons' and patients' needs while reducing costs and streamlining stock. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Analysis of suture anchor eyelet position on suture failure load.
Aktay, Sevima A; Kowaleski, Michael P
2011-06-01
To compare mechanical performance of 2 orientations of the 5 mm Corkscrew® suture anchor with #5 Fiberwire® . In vitro biomechanical study. Suture anchor-suture constructs (n=40). Acute and cyclic tensile loads were applied to suture threaded through eyelets of 40 anchors perpendicular to the long axis of the anchor. Eyelets were positioned so that the suture pull was in line with (anchor rotation angle of 0° [ARA 0]) or 90° (ARA 90) to the eyelet plane. Load at failure, stiffness, and cycles to failure were determined. All constructs failed by suture breakage at the eyelet. Mean load at failure was significantly higher in the ARA 90 group (634 ± 93 N) compared with the ARA 0 group (495 ± 52 N; P=.0015). No significant difference was found between groups for mean number of cycles to failure (270 ± 177 versus 178 ± 109; P=.2166) and stiffness (50 ± 4 versus 48 ± 5 N/mm; P=.3141). The Corkscrew® 5 mm suture anchor with Fiberwire® suture fails via suture breakage at the eyelet under higher acute loads if the suture is loaded at an angle of 90° compared with 0° with respect to the plane of the eyelet. © Copyright 2011 by The American College of Veterinary Surgeons.
Perez-Blanca, Ana; Prado Nóvoa, María; Lombardo Torre, Maximiano; Espejo-Reina, Alejandro; Ezquerro Juanco, Francisco; Espejo-Baena, Alejandro
2018-04-01
To assess the role of suture cutout in the mechanics of failure of the repaired posterior meniscal root during the early post-operative period when using sutures of different shape. Twenty medial porcine menisci were randomized in two groups depending on the suture shape used to repair the posterior root: thread or tape. The sutured menisci were subjected to cyclic loading (1000 cycles, (10, 30) N) followed by load-to-failure testing. Residual displacements, stiffness, and ultimate failure load were determined. During tests, the tissue-suture interface was recorded using a high-resolution camera. In cyclic tests, cutout progression at the suture insertion points was not observed for any specimen of either group and no differences in residual displacements were found between use of thread or tape. In load-to-failure tests, suture cutout started in all menisci at a load close to the ultimate failure and all specimens failed by suture pullout. Suture tape had a greater ultimate load with no other differences. In a porcine model of a repaired posterior meniscal root subjected to cyclic loads representative of current rehabilitation protocols in the early post-operative period under restricted loading conditions, suture cutout was not found as a main source of permanent root displacement when using suture thread or tape. Suture cutout progression started at high loading levels close to the ultimate load of the construct. Tape, with a meniscus-suture contact area larger than thread, produced higher ultimate load.
Cranial suture biology of the Aleutian Island inhabitants.
Cray, James; Mooney, Mark P; Siegel, Michael I
2011-04-01
Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations. Copyright © 2011 Wiley-Liss, Inc.
Antibacterial Surgical Silk Sutures Using a High-Performance Slow-Release Carrier Coating System.
Chen, Xiaojie; Hou, Dandan; Wang, Lu; Zhang, Qian; Zou, Jiahan; Sun, Gang
2015-10-14
Sutures are a vital part for surgical operation, and suture-associated surgical site infections are an important issue of postoperative care. Antibacterial sutures have been proved to reduce challenging complications caused by bacterial infections. In recent decades, triclosan-free sutures have been on their way to commercialization. Alternative antibacterial substances are becoming relevant to processing surgical suture materials. Most of the antibacterial substances are loaded directly on sutures by dipping or coating methods. The aim of this study was to optimize novel antibacterial braided silk sutures based on levofloxacin hydrochloride and poly(ε-caprolactone) by two different processing sequences, to achieve suture materials with slow-release antibacterial efficacy and ideal physical and handling properties. Silk strands were processed into sutures on a circular braiding machine, and antibacterial treatment was introduced alternatively before or after braiding by two-dipping-two-rolling method (M1 group and M2 group). The antibacterial activity and durability against Staphylococcus aureus and Escherichia coli were tested. Drug release profiles were measured in phosphate buffer with different pH values, and release kinetics model was built to analyze the sustained drug release mechanism between the interface of biomaterials and the in vitro aqueous environment. Knot-pull tensile strength, thread-to-thread friction, and bending stiffness were determined to evaluate physical and handling properties of sutures. All coated sutures showed continuous antibacterial efficacy and slow drug release features for more than 5 days. Besides, treated sutures fulfilled U.S. Pharmacopoeia required knot-pull tensile strength. The thread-to-thread friction and bending stiffness for the M1 group changed slightly when compared with those of uncoated ones. However, physical and handling characteristics of the M2 group tend to approach those of monofilament ones. The novel suture showed acceptable in vitro cytotoxicity according to ISO 10993-5. Generally speaking, all coated sutures show potential in acting as antibacterial suture materials, and M1 group is proved to have a higher prospect for clinical applications.
Younesi, Mousa; Knapik, Derrick M; Cumsky, Jameson; Donmez, Baris Ozgur; He, Ping; Islam, Anowarul; Learn, Greg; McClellan, Philip; Bohl, Michael; Gillespie, Robert J; Akkus, Ozan
2017-11-01
Flexor tendon lacerations are traditionally repaired by using non-absorbable monofilament sutures. Recent investigations have explored to improve the healing process by growth factor delivery from the sutures. However, it is difficult to conjugate growth factors to nylon or other synthetic sutures. This study explores the performance of a novel electrochemically aligned collagen suture in a flexor tendon repair model with and without platelet derived growth factor following complete tendon laceration in vivo. Collagen suture was fabricated via electrochemical alignment process. Heparin was covalently bound to electrochemically aligned collagen sutures (ELAS) to facilitate affinity bound delivery of platelet-derived growth factor-BB (PDGF-BB). Complete laceration of the flexor digitorum profundus in the third digit of the foot was performed in 36 skeletally mature White Leghorn chickens. The left foot was used as the positive control. Animals were randomly divided into three groups: control specimens treated with standard nylon suture (n=12), specimens repaired with heparinated ELAS suture without PDGF-BB (n=12) and specimens repaired with heparinated ELAS suture with affinity bound PDGF-BB (n=12). Specimens were harvested at either 4weeks or 12weeks following tendon repair. Differences between groups were evaluated by the degree of gross tendon excursion, failure load/stress, stiffness/modulus, absorbed energy at failure, elongation/strain at failure. Quantitative histological scoring was performed to assess cellularity and vascularity. Closed flexion angle measurements demonstrated no significant differences in tendon excursion between the study groups at 4 or 12weeks. Biomechanical testing showed that the group treated with PDGF-BB bound heparinated ELAS suture had significantly higher stiffness and failure load (p<0.05) at 12-weeks relative to both heparinated ELAS suture and nylon suture. Similarly, the group treated with PDGF-BB bound suture had significantly higher ultimate tensile strength and Young's modulus (p<0.05) at 12-weeks relative to both ELAS suture and nylon suture. Compared to nylon controls, heparinized ELAS with PDGF-BB improved biomechanics and vascularity during tendon healing by 12-weeks following primary repair. The ability of ELAS to deliver PDGF-BB to the lacerated area of tendon presents investigators with a functional bioinductive platform to improve repair outcomes following flexor tendon repair. A high strength aligned collagen suture was fabricated via linear electrocompaction and heparinized for prolonged delivery of PDFG-BB. When it was used to suture a complete lacerated flexor tendon in a chicken model controlled release of the PDGF-BB improved the strength of treated tendon after 12 weeks compared to tendon sutured with commercial nylon suture. Furthermore, Collagen suture with affinity bound PDGF-BB enhanced the vascularization and remodeling of lacerated tendon when it compare to synthetic nylon suture. Overall, electrocompacted collagen sutures holds potential to improve repair outcome in flexor tendon surgeries by improving repair strength and stiffness, vascularity, and remodeling via sustained delivery of the PDGF-BB. The bioinductive collagen suture introduces a platform for sustained delivery of other growth factors for a wide-array of applications. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
[Manual suture versus/or mechanical suture from the Austrian viewpoint].
Kronberger, L; Germann, R
1987-01-01
A general inquiry was made at surgical units and university clinics in Austria about the anastomosis techniques used between 1980 to 1985. The result was that in 90.3% the suture was made by hand and in 9.7% by machine. The first mentioned was performed as double row inverting suture by 66% of our surgeons, and only in 30% as an all-layer suture. The stapler-technique was mostly preferred for the oesophago-jejunostomy and the high and lower resection of the rectum. A leakage of the suture line was observed in 3.9% after sewing by hand and in 6.3% after stapling. The total lethality finally was 1.4% for hand made suture and 1.8% for apparative suture.
Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.
Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y
2016-05-01
Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.
A mathematical model was developed to predict changes in contaminant concentrations with time, and to estimate contaminant fluxes due to migration, diffusion, and convection in a laboratory-scale batch electrolysis cell for the regeneration of contaminated har...
21 CFR 73.1327 - Chromium oxide greens.
Code of Federal Regulations, 2010 CFR
2010-04-01
... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1327 Chromium oxide greens. (a) Identity. (1) The color additive chromium oxide greens is principally chromic sesquioxide (Cr2O3). (2) Color additive... subpart as safe and suitable for use in color additive mixtures for coloring drugs. (b) Specifications...
The USEPA has created the Environmental Technology Verification (ETV) Program to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The ETV P2 Metal Finishing Technologies (ETV-MF) Prog...
AMORPHOUS ALLOY SURFACE COATINGS FOR HARD CHROMIUM REPLACEMENT - PHASE I
Hard chromium coatings (0.25 to10 mil thick) are used extensively for imparting wear and erosion resistance to components in both industrial and military applications. The most common means of depositing hard chromium has been through the use of chromic acid baths containing ...
Zellner, Eric M; Hedlund, Cheryl S; Kraus, Karl H; Burton, Andrew F; Kieves, Nina R
2016-06-15
OBJECTIVE To compare suture placement time, tension at skin separation and suture line failure, and mode of failure among 4 suture patterns. DESIGN Randomized trial. SAMPLE 60 skin specimens from the pelvic limbs of 30 purpose-bred Beagles. PROCEDURES Skin specimens were harvested within 2 hours after euthanasia and tested within 6 hours after harvest. An 8-cm incision was made in each specimen and sutured with 1 of 4 randomly assigned suture patterns (simple interrupted, cruciate, intradermal, or subdermal). Suture placement time and percentage of skin apposition were evaluated. Specimens were mounted in a calibrated material testing machine and distracted until suture line failure. Tensile strength at skin-edge separation and suture-line failure and mode of failure were compared among the 4 patterns. RESULTS Mean suture placement time for the cruciate pattern was significantly less than that for other patterns. Percentage of skin apposition did not differ among the 4 patterns. Mean tensile strength at skin-edge separation and suture-line failure for the simple interrupted and cruciate patterns were significantly higher than those for the intradermal and subdermal patterns. Mean tensile strength at skin-edge separation and suture-line failure did not differ significantly between the intradermal and subdermal patterns or the simple interrupted and cruciate patterns. The primary mode of failure for the simple interrupted pattern was suture breakage, whereas that for the cruciate, intradermal, and subdermal patterns was tissue failure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested external skin sutures may be preferred for closure of incisions under tension to reduce risk of dehiscence.
de Carvalho, Marcus Vinicius H.; Marchi, Evaldo; Lourenço, Edmir Américo
2017-01-01
Introduction Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. Conclusion There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries. PMID:29267611
Current manufacturing processes of drug-eluting sutures.
Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine
2017-11-01
Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.
Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile
2017-10-01
Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality. The high friction force of surgical sutures in the suturing process may cause inflammation and pain to the person, leading to a longer recovery time, and the second trauma of soft or fragile tissue. Thus, the investigation into the frictional performance of surgical suture is essential. Despite the unquestionable fact, little is actually known on the friction performances of surgical suture-tissue due to the lack of appropriate test equipment. This study presents a new penetration friction apparatus (PFA) that allowed for the evaluation of the friction performances of various surgical needles and sutures during the suturing process, under different contact conditions. It considered the deformation of tissue and can realize the puncture force measurements of surgical needles as well as the friction force of surgical sutures. The developed PFA could accurately evaluate and understand the frictional behaviour of surgical suture-tissue in the simulating clinical conditions. The forces measured by the PFA showed the same trend as that reported in literatures. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2011-01-01
Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. PMID:21385182
Betz, C; Schleicher, P; Winkel, R; Hoffmann, R
2013-02-01
In this study we examined the tensile strength of core sutures of tendons. In particular, we examined the effect of having 2 or 4 stitch strands in the core suture as well as the effect of additional locking sutures on the tensile strength. 60 flexor tendons from the forepaws of freshly slaughtered swines were harvested for biomechanical testing. They were divided into 4 groups (A, B, C and D) of 15 sutures each. Group A: core suture after Zechner with 2 strands; group B: modified core suture with 4 strands; group C: modified core suture with 2 strands and 4 locking sutures; group D: modified core suture with 4 strands and 4 locking sutures. The primary tensile strength of the sutures was measured in Newton using the testing machine with a traction speed of 0.1 mm/s. Simultaneously, the increasing space forming at the suture was filmed against graph paper. Our command variables were force measured in Newton when forming a space of 2 mm as well as the force at which the suture failed. Statistical analysis was carried out with the software SPSS to produce a multivariate analysis with a statistical significance of p<0.05. Results are presented as averages including the 1st and 3rd quartile (1Q/3Q). Under traction to form a 2 mm space, the force measured with group A was 14.2 N (12.9/15.1 N). In group B the force 22.5 N (20.0/24.7 N) was significantly higher (p<0.05). Group C required a traction force of 28.7 N (23.5/35.8 N) which was significantly higher than for groups A and B. Group D required the significantly highest traction force of 42.0 N (39.5/46.0 N) to produce a 2 mm space. The force required for the suture to fail in group A was 19.9 N (17.9/22.8 N), in group B: 26.2 N (24.5/29.7 N), in group C 32.0 N (27.1/40.1 N) and in Group D 46.5 N (41.5/50.0 N); the differences between the gloups were all statistically significant. The primary tensile strength of core sutures after Zechner on flexor tendons from the forepaws of swines was significantly increased by doubling the number of sutures and also by use of 4 additional locking sutures. © Georg Thieme Verlag KG Stuttgart · New York.
Coons, David A; Barber, F Alan; Herbert, Morley A
2006-11-01
This study evaluated the strength and suture-tendon interface security of different suture configurations from triple-suture-loaded anchors. A juvenile bovine infraspinatus tendon was detached and repaired by use of 4 different suture combinations from 2 suture anchors: 3 simple sutures in each anchor (ThreeVo anchor; Linvatec, Largo, FL); 2 peripheral simple stitches and 1 central horizontal mattress suture passed deeper into the tendon, creating a larger footprint (bigfoot-print anchor); 2 peripheral simple stitches with 1 central horizontal mattress stitch passed through the same holes as the simple sutures (stitch-of-Burns); and 2 simple stitches (TwoVo anchor; Linvatec). The constructs were cyclically loaded between 10 N and 180 N for 3,500 cycles and then destructively tested. The number of cycles required to create a 5-mm gap and a 10-mm gap and the ultimate load to failure and failure mode were recorded. The ThreeVo anchor was strongest and most resistant to cyclic loading (P < .01). The TwoVo anchor was least resistant to cyclic loading. The stitch-of-Burns anchor was more resistant to cyclic loading than both the bigfoot-print anchor and the TwoVo anchor (P < .03). The ThreeVo, stitch-of-Burns, and TwoVo anchors were stronger than the bigfoot-print anchor (P < .05). Three simple sutures in an anchor hold better than two simple sutures. Three simple sutures provide superior suture-tendon security than combinations of one mattress and two simple stitches subjected to cyclic loading. A central mattress stitch placed more medially than two peripheral simple stitches (bigfoot-print anchor) configured to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as three simple stitches (ThreeVo anchor). Placing a central mattress stitch more medially than 2 peripheral simple stitches to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as 3 simple stitches.
Shibazaki-Yorozuya, Reiko; Wang, Qian; Dechow, Paul C; Maki, Koutaro; Opperman, Lynne A
2012-06-01
Craniofacial sutures are bone growth fronts that respond and adapt to biomechanical environments. Little is known of the role sutures play in regulating the skull biomechanical environment during patency and fusion conditions, especially how delayed or premature suture fusion will impact skull biomechanics. Tgf-β3 has been shown to prevent or delay suture fusion over the short term in rat skulls, yet the long-term patency or its consequences in treated sutures is not known. It was therefore hypothesized that Tgf-β3 had a long-term impact to prevent suture fusion and thus alter the skull biomechanics. In this study, collagen gels containing 3 ng Tgf-β3 were surgically placed superficial to the posterior interfrontal suture (IFS) and deep to the periosteum in postnatal day 9 (P9) rats. At P9, P24, and P70, biting forces and strains over left parietal bone, posterior IFS, and sagittal suture were measured with masticatory muscles bilaterally stimulated, after which the rats were sacrificed and suture patency analyzed histologically. Results demonstrated that Tgf-β3 treated sutures showed less fusion over time than control groups, and strain patterns in the skulls of the Tgf-β3-treated group were different from that of the control group. Although bite force increased with age, no alterations in bite force were attributable to Tgf-β3 treatment. These findings suggest that the continued presence of patent sutures can affect strain patterns, perhaps when higher bite forces are present as in adult animals. Copyright © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark
2005-12-01
The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.
Bailleul, Alida M; Horner, John R
2016-08-01
Sutures and synchondroses, the fibrous and cartilaginous articulations found in the skulls of vertebrates, have been studied for many biological applications at the morphological scale. However, little is known about these articulations at the microscopic scale in non-mammalian vertebrates, including extant archosaurs (birds and crocodilians). The major goals of this paper were to: (i) document the microstructure of some sutures and synchondroses through ontogeny in archosaurs; (ii) compare these microstructures with previously published sutural histology (i.e. that of mammals); and (iii) document how these articulations with different morphological degrees of closure (open or obliterated) appear histologically. This was performed with histological analyses of skulls of emus, American alligators, a fossil crocodilian and ornithischian dinosaurs (hadrosaurids, pachycephalosaurids and ceratopsids). Emus and mammals possess a sutural periosteum until sutural fusion, but it disappears rapidly during ontogeny in American alligators. This study identified seven types of sutural mineralized tissues in extant and extinct archosaurs and grouped them into four categories: periosteal tissues; acellular tissues; fibrous tissues; and intratendinous tissues. Due to the presence of a periosteum in their sutures, emus and mammals possess periosteal tissues at their sutural borders. The mineralized sutural tissues of crocodilians and ornithischian dinosaurs are more variable and can also develop via a form of necrosis for acellular tissues and metaplasia for fibrous and intratendinous tissues. It was hypothesized that non-avian dinosaurs, like the American alligator, lacked a sutural periosteum and that their primary mode of ossification involved the direct mineralization of craniofacial sutures (instead of intramembranous ossification found in mammals and birds). However, we keep in mind that a bird-like sutural microstructure might have arisen within non-avian saurichians. While synchondroseal histology is relatively similar in archosaurs and mammals, the microstructural differences between the sutures of these two clades are undeniable. Moreover, the current results suggest that the degree of sutural closure can only accurately be known via microstructural analyses. This study sheds light on the microstructure and growth of archosaurian sutures and synchondroses, and reveals a unique, undocumented histological diversity in non-avian dinosaur skulls. © 2016 Anatomical Society.
21 CFR 73.1326 - Chromium hydroxide green.
Code of Federal Regulations, 2010 CFR
2010-04-01
... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1326 Chromium hydroxide green. (a) Identity. (1) The color additive chromium hydroxide green is principally hydrated chromic sesquioxide (Cr2O3·XH2O). (2) Color additive mixtures for drug use made with chromium hydroxide green may contain only those...
An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.
Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P
2017-11-01
Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P < .001). The footprint coverage of the simple suture and horizontal mattress suture groups was not significantly different ( P = .44). There were no significant differences in load to failure, cyclic displacement, or stiffness between the single-row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior biomechanical properties compared with single-row repair techniques. There was no difference in footprint coverage or biomechanical strength between the simple suture and horizontal mattress suture repair techniques. Although the double-row repair techniques had no difference in initial strength, they may improve healing in high-risk patients by improving the footprint coverage.
Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
Chacon, Anna H; Shiman, Michael I; Strozier, Narissa; Zaiac, Martin N
2013-01-01
Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion. PMID:23723610
NASA Astrophysics Data System (ADS)
Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team
2011-03-01
Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.
Peer-assisted teaching of basic surgical skills.
Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip
2015-01-01
Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p < 0.001), and the standard deviation of mean inter-suture distance halved from ± 4.7 mm pre-teaching, to ± 2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Peer-assisted learning suturing workshops can enhance medical students' competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2011-05-01
Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society of Great Britain and Ireland.
Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; von Deimling, Constantin; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias
2018-01-01
Background Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. Objectives This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. Methods As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Results Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log). Conclusions Novel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first–clinically most relevant– 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications. PMID:29315313
Obermeier, Andreas; Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; Deimling, Constantin von; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias; Burgkart, Rainer; von Eisenhart-Rothe, Rüdiger
2018-01-01
Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log). Novel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first-clinically most relevant- 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications.
[Application of inner figure-of-eight suture to laparoscopic colorectal surgery].
Chen, Jianjun; Zhong, Ming
2018-03-25
Regardless of laparoscopic or open colorectal surgeries, intestinal anastomosis is usually an important operative procedure. Even if stapler is widely used in different intestinal surgery nowadays, hand sewn suture is an indispensable procedure in clinical practice, meanwhile after stapled anastomosis, additional hand sewn suture is usually performed to ensure the safety of anastomosis. The inner figure-of-eight suture is a single layer suture technique which has been widely used in skin, tendon, rectus and uterus for quick and secure approximation. We describe our innovative application of inner figure-of-eight suture technique for intestinal anastomosis and/or reinforcement after stapled anastomosis in laparoscopic colorectal surgery. Main steps of inner figure-of-eight suture for intestinal anastomosis on posterior wall are as follows: (1) At 4 mm from cut edge of bowel, needle enters vertically from one side and courses mucosa-serosa-opposite serosa-mucosa in parallel to the entry point. (2) The needle is brought back to first entry side of bowel at 45 degree to enter the mucosa 5 mm below the first entry point and out on opposite side mucosa horizontally. (3) Both lose ends of the suture are pulled to approximate bowel edges and knots are tied on mucosal surface, in which suture line presents figure-of-eight on mucosal surface and two parallel suture lines are seen on serosal surface. When inner figure-of-eight suture is performed on anterior wall, the procedure is similar, but needle passes from serosa-mucosa-opposite mucosa-serosa and repeated to complete the inner figure-8 suture and knots are tied on serosa. The final look is two parallel sutures at 0.5 mm in between and the figure-of-eight remains inside the lumen. We did not deliberately try to invert the bowel edges, and if anastomosis is not satisfactory at final examination, simple interrupted seromuscular suture can be carried out. From 2015 till now, we have successfully completed inner figure-of-eight sutures in 38 cases receiving intestinal anastomosis reinforcement procedure and in 24 cases receiving hand sewn anastomosis. Comparison study revealed inner figure-of-eight suture presented shorter anastomotic time and less medical cost without anastomotic leakage, stump leakage or bleeding. No anastomotic stenosis was found at enteroscopy examination during follow up. We think that inner figure-of-eight suture possesses safe and simple advantages and is a manual suture technique worthy of promotion.
Khonsari, R H; Di Rocco, F; Arnaud, E; Sanchez, S; Tafforeau, P
2012-09-01
The developmental genetics and the biomechanics of sutures are well-studied topics, while their microanatomy is still imperfectly known. Here, we aim to investigate the structure of skull vault sutures using a high-resolution imaging device. We used synchrotron X-ray microtomography in order to obtain high-resolution images of skull vault sutures from an extant mammal (the mouse Mus musculus) and from an extinct fish (the placoderm Compagopiscis croucheri). We used segmentation and 3D reconstruction softwares in order to reveal the microanatomy of sutures in these species. The high-resolution images allowed us to study the distribution of osteocytes, the organisation of vascular canals, the shapes of the suture borders, the insertion of Sharpey's fibres, the bone growth lines and the structure of the soft tissues surrounding the sutures. Synchrotron imaging provides new perspectives for the study of the normal microanatomy of sutures. The submicronic resolution of the synchrotron scans gives access to the 3D organisation of structures that were previously only known in 2D, even in normal sutures. The description of anatomical entities such as vascular canals and Sharpey's fibres in abnormally fused sutures would be of interest in the understanding of craniosynostoses.
Blaker, J J; Nazhat, S N; Boccaccini, A R
2004-01-01
A novel silver-doped bioactive glass powder (AgBG) was used to coat resorbable Vicryl (polyglactin 910) and non-resorbable Mersilk surgical sutures, thereby imparting bioactive, antimicrobial and bactericidal properties to the sutures. Stable and homogeneous coatings on the surface of the sutures were achieved using an optimised aqueous slurry-dipping technique. Dynamic mechanical analysis (DMA) was used to investigate the viscoelastic parameters of storage modulus and tandelta and thermal transitions of the as-received and composite (coated) sutures. The results generally showed that the bioactive glass coating did not affect the dynamic mechanical and thermal properties of the sutures. The in vitro bioactivity of the sutures was tested by immersion in simulated body fluid (SBF). After only 3 days of immersion in SBF, bonelike hydroxyapatite formed on the coated suture surfaces, indicating their enhanced bioactive behaviour. Resorbable sutures with bioactive coatings as fabricated here, in conjunction with 3-D textile technology, may provide attractive materials for producing 3-D scaffolds with controlled porosities for tissue engineering applications. The bactericidal properties imparted by the Ag-containing glass coating open also new opportunities for use of the composite sutures in wound healing and body wall repair.
[Mechanical suture in colorectal surgery].
Alecu, L; Pascu, A; Costan, I; Deacu, A; Marin, A; Corodeanu, G; Gulinescu, L
2001-01-01
Of this work was the study of using, as well as the utility of the mechanical sutures in colorectal surgery; because of the special caution needed to be taken for any colonic or rectal suture, more than any other digestive segment. The frequency of the postoperative fistulas after the suture and anastomosis is higher at this level and so it increases the period and costs of the hospitalization. We studied the possibilities of performing and evolution of 64 mechanical sutures for 19 patients, with colorectal pathology, hospitalized in our department from july 1999 to december 2000. We performed 64 mechanical sutures, as followed: 47 in open surgery and 17 in laparoscopic. From all these, 56 was bowel sutures, 8 of them were vascular (in laparoscopic, for cutting the most important vascular pedicles). We did 18 anastomosis: 15 in open and 3 in laparoscopic surgery. It was 2 postoperative fistulas from all 56 intestinal sutures (3.57%). We haven't any intra or postoperative bleeding from the vascular anastomosis. It was 3 intraoperative bleeding from the intestinal anastomosis, and only 1 case of postoperative bleeding (5.26% of the cases: 1.56% of all mechanical sutures). In only one case, the mechanical suture couldn't be initially done, but it succeeded after the removing of the segment of the bowel involved. Mechanical sutures offers a high level of safety to the colorectal anastomosis. It provides a very good vascularization to the anastomosis and decreases the time needed for performing the suture or anastomosis, versus manual sature. Also, for the patients with rectal ampular neoplasm, it creates the possibility of anal sphincter preservation by making a low colorectal anastomoses--which is difficult by manual suture.
Shear lag sutures: Improved suture repair through the use of adhesives
Linderman, Stephen W.; Kormpakis, Ioannis; Gelberman, Richard H.; Birman, Victor; Wegst, Ulrike G. K.; Genin, Guy M.; Thomopoulos, Stavros
2015-01-01
Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966
Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).
von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel
2008-04-01
The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.
Cranial suture complexity in caviomorph rodents (Rodentia; Ctenohystrica).
Buezas, Guido; Becerra, Federico; Vassallo, Aldo
2017-08-01
Due to their flexibility, sutures are regions that experience greater strains than the surrounding rigid cranial bones. Cranial sutures differ in their degree of interdigitation or complexity. There is evidence indicating that a more convoluted suture better enables the absorption of high stresses coming from dynamic masticatory forces, and other functions. The Order Rodentia is an interesting clade to study this because of its taxa with diverse chewing modes. Due to repeated loading resulting from gnawing and grinding, energy absorption by the sutures might be a crucial factor in these mammals. Species within the infraorder Caviomorpha were chosen as a case study because of their ecomorphological and dietary diversity. This study compared five sutures from the rostrum and cranial vault across seven caviomorph families, and assessed their complexity by means of the relative length and fractal dimension. Across these rodents, cranial sutures are morphologically quite diverse. We found that the sutures connecting the rostrum with the vault were relatively more interdigitated than those in the cranial vault itself, especially premaxillofrontal sutures. Suture interdigitation was higher in species that display chisel-tooth digging and burrowing behaviors, especially in the families Ctenomyidae and Octodontidae, than those in families Dasyproctidae and Cuniculidae, which have more gracile masticatory systems. The reconstruction of the ancestral character state, on family and species phylogeny, points toward low suture interdigitation (i.e., low length ratio) as a likely ancestral state for interfrontal, premaxillofrontal and maxillofrontal sutures. Interspecific differences in suture morphology shown here might represent adaptations to different mechanical demands (i.e., soft vs. tough foods) or behaviors (e.g., chisel-tooth digging), which evolved in close association with the diverse environments occupied by caviomorph rodents. © 2017 Wiley Periodicals, Inc.
Cho, Byung-Ki; Kim, Yong-Min; Park, Kyoung-Jin; Park, Ji-Kang; Kim, Do-Kyoon
2015-02-01
There are various ligament reattachment techniques for the modified Brostrom procedure. There have been few comparative studies on recently developed techniques. This prospective study was performed to compare the functional outcomes of 2 different ligament reattachment techniques using suture anchors. We furthermore evaluated the cost-effectiveness of the suture bridge technique. Forty-five amateur athletes under 30 years of age were followed for more than 2 years. Twenty-four procedures with the suture anchor technique and 21 procedures with the suture bridge technique were performed by one surgeon. The functional evaluation consisted of the American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Outcome Score (FAOS), Karlsson score, Sefton grading system, and the period to return to various forms of exercise (jogging, spurt running, jumping, one leg standing for >1 minute, walking on uneven ground, and going down stairs). Measurement of talar tilt angle and anterior talar translation was obtained from stress radiographs to evaluate mechanical stability. There were no significant differences on AOFAS score, FAOS, Karlsson score, Sefton grade, and stress radiographs. There were no significant differences on the return to exercises, except for jumping. As the most common complication, there were 3 cases of skin irritation by suture materials in the suture anchor group and 2 cases of intraoperative breakage of the suture anchor in suture bridge group. Both ligament reattachment techniques using suture anchors showed similar functional outcomes. Considering the additional medical expenses incurred by more suture anchors, the modified Brostrom procedure using the suture bridge technique had low cost-effectiveness. Proper indication and clinical usefulness of suture bridge technique for chronic ankle instability will be addressed in further studies. Level II, prospective comparative study. © The Author(s) 2014.
Laparoscopic percutaneous jejunostomy with intracorporeal V-Loc jejunopexy in esophageal cancer.
Yang, Shun-Mao; Hsiao, Wei-Ling; Lin, Jui-Hsiang; Huang, Pei-Ming; Lee, Jang-Ming
2017-06-01
Barbed sutures are widely used in various laparoscopic digestive surgeries. The purpose of this paper is to present our initial experience of laparoscopic percutaneous jejunostomy with unidirectional barbed sutures in esophageal cancer patients and compare it with our early cases using traditional transabdominal sutures. A total of 118 esophageal cancer patients who underwent laparoscopic percutaneous jejunostomy were identified in a single institution in Taiwan from June 2014 to May 2016. The authors' traditional technique consisted of using transabdominal sutures with bolsters to fix a jejunum loop onto the anterior abdominal wall. A novel technique was introduced using intracorporeal suturing with knotless unidirectional barbed monofilament absorbable sutures (V-Loc) to attain a seal around the feeding catheter. A comparison between these two techniques was performed. Twenty cases with barbed V-Loc sutures and 98 cases with transabdominal sutures were identified. The V-Loc sutures appeared to reduce peristomal skin ulcers (19.4 vs. 0 %, p = 0.040), postoperative pain scores during the first 24 h (1.8 ± 1.4 vs. 0.9 ± 1.1, p = 0.007) and on postoperative day 2 (1.7 ± 1.4 vs. 1.0 ± 0.8, p = 0.026) when compared to patients receiving transabdominal sutures. The mean suturing time using V-Loc sutures was 22 min (14-60 min). The mean onset to resumption of enteral feeding was 1.8 ± 0.8 days and the mean duration of postoperative hospital stay was 8 ± 5.1 days, both of which were comparable in the two groups. There was no surgical mortality in our series. In the study cohort, the use of knotless unidirectional barbed sutures instead of traditional transabdominal sutures had similar outcomes and appears to be a feasible option for intracorporeal jejunopexy when performing laparoscopic jejunostomy in patients with esophageal cancer.
Lambertz, Andreas; Schröder, Kai Michael; Schöb, Dominik Stefan; Binnebösel, Marcel; Anurov, Michael; Klinge, Uwe; Neumann, Ulf Peter; Klink, Christian Daniel
2015-01-01
Biocompatibility and tissue integration of a surgical suture are decisive factors for wound healing and therefore for the success of sutures. The optimal suture material is still under discussion. Polyvinylidene fluoride (PVDF) is described to have superior properties of biocompatibility and is therefore frequently used as a mesh component. Only little information is available about its use as a suture material. The aim of this study was to evaluate the biocompatibility of PVDF as a suture material in comparison to 5 different established sutures in a rat model. In 30 male rats, a monofilamental PVDF suture (Resopren®) and 5 established control suture materials [polyester (Miralene®), polytetrafluoroethylene (Gore®), poliglecaprone (Monocryl®), polydioxanone (Monoplus®), polyglactin 910 (Vicryl®), USP size 3-0] were placed in the subcutaneous layer of the abdominal wall without knot or tension. After 3, 7 or 21 days, the abdominal walls were explanted for histopathological and immunohistochemical investigation with special regard to the size and quality of foreign body granuloma and the length of the comet tail-like infiltrate (CTI). The PVDF sutures showed the smallest size of foreign body granuloma (60 ± 14 µm) and the smallest CTI length (343 ± 60 µm) of all polymers after 21 days. Only PVDF (Resopren) and polydioxanone (Monoplus) showed a significant collagen I/III ratio increase between days 3 and 21 (p = 0.009 and p = 0.016). The quality of foreign body reaction regarding inflammation, proliferation and fibrotic remodeling was similar between all suture materials. Our data indicate that monofilamental PVDF sutures show a favorable foreign body reaction with small granuloma sizes and CTI length in comparison to established sutures. Its use as a suture material in general surgery could therefore be extended in the future. To reinforce these findings, further clinical studies need to be conducted. 2015 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.
Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiationmore » (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.« less
Huh, Beom Kang; Kim, Byung Hwi; Kim, Se-Na; Park, Chun Gwon; Lee, Seung Ho; Kim, Ka Ryeong; Heo, Chan Yeong; Choy, Young Bin
2017-10-01
In this work, we propose a surgical suture that can sustainably release diclofenac (DF) for the local pain relief of surgical wounds. We separately fabricated a DF-loaded strand composed of a biodegradable polymer, poly(lactic-co-glycolic acid) (PLGA), which was then braided with a surgical suture already in clinical use, i.e., VICRYL™. In this way, the drug-delivery suture presented herein could release DF in a sustained manner for 10days while maintaining the mechanical strength needed for wound closure. According to the in vivo results of an induced-pain animal model, the drug-delivery suture mitigated pain throughout the period of persistent pain. The histological analysis of tissue around the sutures showed that the drug-delivery suture exhibited biocompatibility comparable to that of the VICRYL™ suture in clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.
Mudgil, A V; To, K W; Balachandran, R M; Janigian, R H; Tsiaras, W G
1999-01-01
To determine the optimal wavelength for subconjunctival laser suture lysis. 130 black monofilament 10-0 nylon sutures were sewn subconjunctivally into the bare sclera of enucleated rabbit globes. The lowest energy levels facilitating laser suture lysis were determined for the argon green (514.5 NM), argon blue-green (488.0 NM, 514.5 NM), and krypton red (647.1 NM) wavelengths. In addition, absorption spectroscopy was performed on the suture material and conjunctiva using the Perkin Elmer W/VIS Lambda 2 spectrometer. Krypton red produced the fewest buttonhole defects, and it was also the most efficient energy source for suture lysis (P = 0.0001) under nontenectomized conjunctiva. Absorbance spectra studies revealed peak absorbance at 628 NM for the 10-0 nylon suture material. Based on animal and absorption spectroscopy studies, krypton red may be a safer and more efficient wavelength for subconjunctival laser suture lysis.
Characterization of craniofacial sutures using the finite element method.
Maloul, Asmaa; Fialkov, Jeffrey; Wagner, Diane; Whyne, Cari M
2014-01-03
Characterizing the biomechanical behavior of sutures in the human craniofacial skeleton (CFS) is essential to understand the global impact of these articulations on load transmission, but is challenging due to the complexity of their interdigitated morphology, the multidirectional loading they are exposed to and the lack of well-defined suture material properties. This study aimed to quantify the impact of morphological features, direction of loading and suture material properties on the mechanical behavior of sutures and surrounding bone in the CFS. Thirty-six idealized finite element (FE) models were developed. One additional specimen-specific FE model was developed based on the morphology obtained from a µCT scan to represent the morphological complexity inherent in CFS sutures. Outcome variables of strain energy (SE) and von Mises stress (σvm) were evaluated to characterize the sutures' biomechanical behavior. Loading direction was found to impact the relationship between SE and interdigitation index and yielded varied patterns of σvm in both the suture and surrounding bone. Adding bone connectivity reduced suture strain energy and altered the σvm distribution. Incorporating transversely isotropic material properties was found to reduce SE, but had little impact on stress patterns. High-resolution µCT scanning of the suture revealed a complex morphology with areas of high and low interdigitations. The specimen specific suture model results were reflective of SE absorption and σvm distribution patterns consistent with the simplified FE results. Suture mechanical behavior is impacted by morphologic factors (interdigitation and connectivity), which may be optimized for regional loading within the CFS. © 2013 Elsevier Ltd. All rights reserved.
In Vitro Tensile Strength Study on Suturing Technique and Material.
González-Barnadas, Albert; Camps-Font, Octavi; Espanya-Grifoll, Dunia; España-Tost, Antoni; Figueiredo, Rui; Valmaseda-Castellón, Eduard
2017-06-01
Suture technique and materials are important in preventing complications such as wound dehiscences. The purpose of this study was to determine the tensile strength of different suturing techniques, comparing several materials with different diameters. One hundred sixty sutures were performed using silk, e-PTFE, and 2 types of polyamide (monofilament and Supramid). Ten simple, 10 horizontal mattress, and 10 combinations of the two stitches were performed with 4-0 gauge of each material. Additionally, 10 simple sutures were performed with the 5-0 gauge of each material. The maximum tensile force resisted by each suture was recorded. When 5 mm of traction was applied, the polyamide monofilament resisted significantly better without untying or breaking compared with Supramid or silk, while the e-PTFE was superior to all the others. However, the force when e-PTFE 4-0 sutures untied or broke was lower than for either type of polyamide. The combined technique withstood a significantly higher tensile force before unknotting or breaking than did the simple and mattress stitches. The 5-0 gauges of silk and both types of polyamide showed lower tensile strengths than the 4-0 materials. Among the 5-0 sutures, Supramid showed a higher tensile strength than silk. The combined suture technique possessed greater tensile strength than did a simple or a horizontal mattress suture, and e-PTFE 4-0 withstood more traction without untying or breaking than did all the other materials, although at a lower tensile force. With the exception of e-PTFE, 4-0 sutures had greater tensile strength than did 5-0 sutures.
Shah, Hemendra N; Nayyar, Rishi; Rajamahanty, Shrinivas; Hemal, Ashok K
2012-06-01
To evaluate the usage of unidirectional barbed suture and its related implications in various surgeon-controlled robotic reconstructive urologic surgeries. From March 2010 to March 2011, all patients undergoing various surgeon-controlled robotic reconstructive urologic surgeries utilizing barbed sutures were prospectively enrolled in this study. Type and number of procedure performed were noted. Intraoperative and peri-operative outcomes potentially related to suture technique and material were recorded. This study reports on 210 patients, in whom barbed suture was used during this period. These included partial nephrectomy (20), pyeloplasty (9), ureteric tailoring and reimplantation (1), closure of bladder after Nephroureterectomy with excision of bladder cuff (8), closure of vaginal cuff in female radical cystectomy (12), partial cystectomy (1), radical prostatectomy (152), simple prostatectomy (2), vesicovaginal fistula repair (3), sacrocolpopexy (1), and hernia repair (1). We encountered 5 instances (2.38%) of tissue cut through possibly attributable to the use of barbed suture and 4 instances of misplacement of suture occurred, of these two required a new suture, whereas retrograde pull back of suture and needle was performed in 2 cases. No instance of slip back/loosening of suture was noted once it was tightened. At mean follow-up of 6.8 (1-14 months) months, we did not encounter any complications of urinary leakage, stone formation or fistula or any clinical evidence of urinary tract obstruction due to the use of barbed suture. Use of unidirectional barbed suture is safe, feasible, and efficient at short-term follow-up for reconstructive part of urological procedures.
Biocompatibility and strength properties of nitinol shape memory alloy suture in rabbit tendon.
Kujala, Sauli; Pajala, Ari; Kallioinen, Matti; Pramila, Antti; Tuukkanen, Juha; Ryhänen, Jorma
2004-01-01
Nitinol (NiTi) is a promising new tendon suture material with good strength, easy handling and good super-elastic properties. NiTi sutures were implanted for biocompatibility testing into the right medial gastrocnemius tendon in 15 rabbits for 2, 6 and 12 weeks. Additional sutures were implanted in subcutaneous tissue for strength measurements in order to determine the effect of implantation on strength properties of NiTi suture material. Braided polyester sutures (Ethibond) of approximately the same diameter were used as control. Encapsulating membrane formation around the sutures was minimal in the case of both materials. The breaking load of NiTi was significantly greater compared to braided polyester. Implantation did not affect the strength properties of either material.
Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery
Cho, Yang Kyeung
2009-01-01
Purpose To evaluate the factors that affect postoperative astigmatism and post-suture removal astigmatism, and to evaluate the risk factors associated with astigmatism axis shift. Methods We performed a retrospective chart review of 130 eyes that had undergone uneventful phacoemulsification cataract surgery. Preoperative astigmatism was divided into four groups (Groups I, II, III, and IV) according to the differences between the axis of preoperative astigmatism (flattest axis) and the incision axis (105 degrees). We analyzed the magnitude and axis of the induced astigmatism after the operation and after suture removal in each group. We also analyzed the factors which affected the postoperative astigmatism and post-suture removal astigmatism in each sub-group of Groups I, II, III, and IV, excluding postoperative or post-suture removal axis shift (specifically, Group IWAS, IIWAS, IIIWAS, and IVWAS). We identified the variables associated with the prevalence of postoperative astigmatism axis shift and those associated with the prevalence of post-suture removal axis shift. Results An increase in the magnitude of postoperative astigmatism was associated with an increase in the preoperative magnitude of astigmatism in Groups IWAS, IIWAS, and IIIWAS (p<0.05), and with an increase in the corneal tunnel length in Group IWAS. A decrease in the magnitude of postoperative astigmatism was associated with an increase in the corneal tunnel length in Groups IIIWAS and IVWAS (p<0.05). An increase in the magnitude of post-suture removal astigmatism was associated with an increase in the magnitude of postoperative astigmatism in Groups IWAS and IVWAS (p<0.05), and with late suture removal in Group IVWAS (p<0.05). A decrease in the magnitude of post-suture removal astigmatism was associated with late suture removal in Groups IWAS and IIWAS. A logistic regression analysis showed that the prevalence of post-suture removal astigmatism axis shift was associated with increased corneal tunnel length, decreased magnitude of postoperative astigmatism, and early suture removal. Conclusions In order to reduce postoperative and post-suture removal astigmatism, we recommend a short corneal tunnel length and late suture removal in patients with Group IWAS characteristics, late suture removal in Group IIWAS-like patients, long corneal tunnel length in Group IIIWAS-like patients, and long corneal tunnel length and early suture removal in patients with characteristics of Group IVWAS. PMID:20046682
Tensile strength and failure load of sutures for robotic surgery.
Abiri, Ahmad; Paydar, Omeed; Tao, Anna; LaRocca, Megan; Liu, Kang; Genovese, Bradley; Candler, Robert; Grundfest, Warren S; Dutson, Erik P
2017-08-01
Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm 2 ), while Silk had the lowest (40-106 kN/cm 2 ). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. Availability of suture tensile strength and failure load data will help define software safety protocols for alerting a surgeon prior to suture failure during robotic surgery. Awareness of suture strength weakening with direct instrument manipulation may lead to the development of better techniques to further reduce intraoperative suture breakage.
Emam, T A; Hanna, G; Cuschieri, A
2002-02-01
Laparoscopic suturing is technically a demanding skill in laparoscopic surgery. Ergonomic experimental studies provide objective information on the important factors and variables that govern optimal endoscopic suturing. Our objective was to determine the optimum physical alignment, visual display, and direction of intracorporeal laparoscopic bowel suturing using infrared motion analysis and telemetric electromyography (EMG) systems. Ten surgeons participated in the study; each sutured 50-mm porcine small bowel enterotomies toward and away from the surgeon in the vertical and horizontal bowel plane with either isoplanar (image display corresponds with actual lie of the bowel) or nonisoplanar (bowel displayed horizontally but mounted vertically in the trainer and vice versa) display. The end points were the placement error score, execution time, leakage pressure, motion analysis, and telemetric EMG parameters of the surgeon's dominant upper limb. Suturing was demonstrably easier in the vertical than in the horizontal plane, resulting in a better task quality (placement error score, p < 0.0001; leakage pressure, p < 0.005) and shorter execution time (p < 0.05). Nonisoplanar display of the surgical anatomy degrades performance in terms of both task efficiency and task quality. On motion analysis, a wider angle of excursion and lower angular velocity were observed during the vertical suturing with isoplaner display. Compared to horizontal suturing, supination at the wrist was significantly greater during vertical than horizontal suturing (p < 0.05). Within each category (vertical vs horizontal suturing), the direction of suturing (toward/away from the surgeon) did not influence the extent of pronation/ supination at the wrist. In line with the degraded performance, significantly more muscle work was expended during horizontal suturing. This affected the forearm flexors (p < 0.05), arm flexors and extensors (p < 0.005 and p < 0.05, respectively), and deltoid muscles (p < 0.005) and was accompanied by significantly more fatigue in the related muscles. Small bowel enterotomies sutured toward the surgeon in both the vertical and the horizontal planes exhibited less placement error score than when sutured away from the surgeon, with no significant difference in the motion analysis and EMG parameters. Optimal laparoscopic suturing (better task quality and reduced execution time) is achieved with vertical suturing toward the surgeon with isoplanar monitor display of the operative field. The poorer task performance observed during horizontal suturing is accompanied by more muscle work and fatigue, and it is not improved by monitor display of the enterotomy in the vertical plane.
Eun, Sang Soo; Lee, Sang Ho; Sabal, Luigi Andrew
2016-08-01
There are numerous methods for repairing posterior root tears of the medial meniscus (PRTMM). Repair techniques using suture anchors through a high posteromedial portal have been reported. The present study found that using a knotless suture anchor instead of suture anchor seemed easier and faster because it avoided passing the sutures through the meniscus and tying a knot in a small space. This study describes a knotless suture anchor technique through a high posteromedial portal, and its clinical results. Copyright © 2016 Elsevier B.V. All rights reserved.
[Auto-suture stapler EEA in surgery of the colon and rectum [author's transl)].
Thiede, A; Troidl, H; Poser, H; Jostarndt, L; Hamelmann, H
1980-01-01
The increasing use of auto-suture staplers for gastrointestinal anastomoses makes it necessary to test the value of this new method of suturing. In a "pilot study" the practicability, the tightness and permeability of the anastomosis and complications were tested and analysed in a total of 30 colon and rectal anastomoses using the EEA-suture gun. The results of 14 colon resections and 16 low anterior resections justify the further use of the EEA auto-suture apparatus and raise the question of a prospective controlled random study in which manual and mechanical machine sutured anastomoses are compared.
Griesser, H J; Chatelier, R C; Martin, C; Vasic, Z R; Gengenbach, T R; Jessup, G
2000-01-01
Fine elastomeric sutures intended for cardiovascular surgery can exhibit "stick-slip" behavior as they are pulled through tissue; the resulting oscillatory force can damage delicate tissue or cause sutures to snap. To eliminate this undesirable effect, sutures were surface-modified using a radiofrequency glow discharge in a vapor of either hexamethyldisiloxane or hexamethyldisilazane, to produce a thin polymeric coating on the suture. The same coatings were also deposited onto aluminized tape to facilitate their characterization by measurement of air/water contact angles and by X-ray photoelectron spectroscopy. Coatings from both monomers were found to be very hydrophobic. The hexamethyldisiloxane glow discharge coatings underwent negligible oxidation when stored in air, and thus remained stable over a shelf-life period akin to what may be required of sutures. The hexamethyldisilazane glow discharge coatings, in contrast, incorporated substantial amounts of oxygen over a 3-month period. The coatings did not measurably alter the tensile properties of the sutures. The frictional properties of coated sutures were assessed by measuring the dynamic friction between the suture and ovine myocardium. Both coatings were effective in removing the inherent stick-slip behavior of polybutester sutures in this model. The coatings remained intact after several passes and proved to be robust and efficacious under various strain regimes. Copyright 2000 John Wiley & Sons, Inc.
Arthroscopically assisted acromioclavicular joint reconstruction.
Baumgarten, Keith M; Altchek, David W; Cordasco, Frank A
2006-02-01
Arthroscopically assisted acromioclavicular joint reconstruction avoids the large incisions necessary with open reconstructions. This acromioclavicular joint reconstruction technique via the subacromial space does not violate the rotator interval or require screw removal. The patient is placed in a modified beach-chair position. The arthroscope is placed into the subacromial space, and a bursectomy is performed through a lateral subacromial portal. The coracoacromial ligament is released from the acromion with an electrocautery and an arthroscopic elevator. A nonabsorbable suture is passed through the coracoacromial ligament with a suture passer, and an arthroscopic suture grasper is used to deliver both ends of the suture out through the lateral portal. The coracoid is identified and isolated using a radiofrequency ablator placed through the anterior portal while visualizing through the lateral portal. A percutaneous shuttle device is passed through the skin superomedial to the coracoid. The shuttle is visualized entering superior to the coracoid and is passed just medial to the coracoid. Once the tip of the shuttle can be visualized in the recess inferior to the coracoid, the shuttle loop is advanced. A suture grasper is used to deliver both ends of the shuttle out through the anterior portal. A semitendinosus allograft is used to reconstruct the coracoclavicular ligament. A nonabsorbable suture is passed through both ends of the allograft. Three strands of nonabsorbable suture are braided together. The tendon and the braided suture are shuttled around the coracoid. At this point, both the braided suture and the allograft tendon enter the anterior portal, wrap around the coracoid base, and exit the anterior portal. A 3-cm incision is made over the distal clavicle. A hole is drilled through the clavicle with a 5-mm drill. A loop of 22-gauge wire is passed through the hole in the clavicle, and a looped suture is shuttled through the hole. A curved clamp is used to create a tunnel from the acromioclavicular joint, under the deltoid, to the anterior portal. The ends of the braided suture and the tendon sutures are grasped by the clamp and pulled out the acromioclavicular joint incision. The limbs of the braided suture and the tendon suture that pass medial to the coracoid are shuttled through the hole in the clavicle using the looped suture that was previously passed through the clavicle. The acromioclavicular joint is reduced by pushing down on the distal clavicle with a bone tamp while simultaneously lifting the acromion upward by superiorly loading the humerus at the elbow. Once the acromioclavicular joint is reduced or slightly over-reduced, the braided suture is tied down securely. The acromioclavicular joint should remain reduced even after the manual reduction maneuver is released. The semitendinosus allograft is tensioned around the distal end of the clavicle and sutured to itself with a nonabsorbable suture. The released coracoacromial ligament is retrieved from the clavicular incision and sutured to the distal clavicle and semitendinosus allograft. The incision is closed in standard fashion, and a sling is applied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, James W.; Deters, Katherine A.; Brown, Richard S.
2011-09-01
Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision-one that may warrant only a single suture for closure. However, it is not known whether a single suture will sufficiently hold the incision closed when fish are decompressed and when outward pressure is placed on the surgical site during turbine passage through hydroelectric dams. The objective of this study was to evaluate the effectiveness of single-suture incision closures on five response variables in juvenile Chinook salmon Oncorhynchus tshawytscha that were subjected to simulated turbine passage. An acoustic transmitter (0.43more » g in air) and a passive integrated transponder tag (0.10 g in air) were implanted in each fish; the 6-mm incisions were closed with either one suture or two sutures. After exposure to simulated turbine passage, none of the fish exhibited expulsion of transmitters. In addition, the percentage of fish with suture tearing, incision tearing, or mortal injury did not differ between treatments. Expulsion of viscera through the incision was higher among fish that received one suture (12%) than among fish that received two sutures (1%). The higher incidence of visceral expulsion through single-suture incisions warrants concern. Consequently, for cases in which tagged juvenile salmonidsmay be exposed to turbine passage, we do not recommend the use of one suture to close 6-mm incisions associated with acoustic transmitter implantation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.
2010-05-01
This study assessed performance of seven suture types in subyearling Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Nonabsorbable (Ethilon) and absorbable (Monocryl) monofilament and nonabsorbable (Nurolon, silk) and absorbable (Vicryl, Vicryl Plus, Vicryl Rapide) braided sutures were used to close incisions in Chinook salmon. Monocryl exhibited greater suture retention than all other suture types 7 d after surgery. Both monofilament suture types were retained better than all braided suture types at 14 d. Incision openness and tag retention did not differ among suture types. Wound inflammation was similar for Ethilon, Monocryl, and Nurolon at 7 d. Wound ulceration wasmore » lower for Ethilon, Monocryl, and Nurolon than for all other suture types at 14 d post-surgery. Fish held in 12°C water had more desirable post-surgery healing characteristics (i.e., higher suture and tag retention and lower incision openness, wound inflammation, and ulceration) at 7 and 14 d after surgery than those held in 17°C water. The effect of surgeon was a significant predictor for all response variables at 7 d. This result emphasizes the importance of including surgeon as a variable in telemetry study analyses when multiple surgeons are used. Monocryl performed better with regard to post-surgery healing characteristics in the study fish. The overall results support the conclusion that Monocryl is the best suture material to close incisions created during surgical implantation of acoustic microtransmitters in subyearling Chinook salmon.« less
The B-Lynch uterine brace suture, and a bit of this and a bit of that...
Karoshi, Mahantesh
2010-03-01
The widespread application of the B-Lynch brace suture to control postpartum hemorrhage has sparked interest in a variety of adjunctive methods, used alone or in combination, to control uterine bleeding. Although the B-Lynch brace suture has been used with good results throughout the world, failures can and do occur in rare instances, especially when the suture is incorrectly placed for use for an inappropriate indication. Four reports of additional methods to control postpartum hemorrhage are published in this issue of IJGO. Three use the B-Lynch brace suture combined with other techniques. The need for additional techniques reminds the reader of the importance of proper suture application for proper indication. Potential reasons for failure of the B-Lynch suture are provided.
Burger, C; Kabir, K; Mueller, M; Rangger, C; Minor, T; Tolba, R H
2006-01-01
In an ovine meniscal repair model, the patellofemoral (PF) osteoarthritis due to a non-sutured tear or failed repair was investigated. A radial meniscus tear was either sutured with polydioxanone (PDS), with a slow degrading polylactide long-term suture(LTS) or left without treatment. Knee joint cartilage in the PF and medial compartment was evaluated compared to normal knees (healthy controls). Retropatellar osteoarthritis in the non-sutured and sutured animals was intense in contrast to the control knees after 6 months in all groups (p < 0.001), and after 12 months in the PDS group (p < 0.001), LTS group and non-sutured animals (p < 0.05). Non-sutured meniscus tears and failed repair lead fast to intense PF osteoarthritis corresponding with tibial damage of the injured compartment.
Tokuhara, Takaya; Nakata, Eiji; Tenjo, Toshiyuki; Kawai, Isao; Kondo, Keisaku; Ueda, Hirofumi; Tomioka, Atsushi
2018-01-01
We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility.
Tokuhara, Takaya; Nakata, Eiji; Tenjo, Toshiyuki; Kawai, Isao; Kondo, Keisaku; Ueda, Hirofumi; Tomioka, Atsushi
2018-01-01
We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility. PMID:29375711
In vitro evaluation of novel antimicrobial coatings for surgical sutures using octenidine.
Obermeier, A; Schneider, J; Föhr, P; Wehner, S; Kühn, K-D; Stemberger, A; Schieker, M; Burgkart, R
2015-09-24
Sutures colonized by bacteria represent a challenge in surgery due to their potential to cause surgical site infections. In order to reduce these type of infections antimicrobially coated surgical sutures are currently under development. In this study, we investigated the antimicrobial drug octenidine as a coating agent for surgical sutures. To achieve high antimicrobial efficacy and required biocompatibility for medical devices, we focused on optimizing octenidine coatings based on fatty acids. For this purpose, antimicrobial sutures were prepared with either octenidine-laurate or octenidine-palmitate at 11, 22, and 33 μg/cm drug concentration normalized per length of sutures. Octenidine containing sutures were compared to the commercial triclosan-coated suture Vicryl® Plus. The release of octenidine into aqueous solution was analyzed and long-term antimicrobial efficacy was assessed via agar diffusion tests using Staphylococcus aureus. For determining biocompatibility, cytotoxicity assays (WST-1) were performed using L-929 mouse fibroblasts. In a 7 days elution experiment, octenidine-palmitate coated sutures demonstrated much slower drug release (11 μg/cm: 7%; 22 μg/cm: 5%; 33 μg/cm: 33%) than octenidine-laurate sutures (11 μg/cm: 82%; 22 μg/cm: 88%; 33 μg/cm: 87%). Furthermore sutures at 11 μg/cm drug content were associated with acceptable cytotoxicity according to ISO 10993-5 standard and showed, similar to Vicryl® Plus, relevant efficacy to inhibit surrounding bacterial growth for up to 9 days. Octenidine coated sutures with a concentration of 11 μg/cm revealed high antimicrobial efficacy and biocompatibility. Due to their delayed release, palmitate carriers should be preferred. Such coatings are candidates for clinical testing in regard to their safety and efficacy.
Electrolytic polishing was performed in a solution of methyl alcohol, sulphuric acid , hydrocloric acid and ethylene glycol. Etching was done...electrolytically in a 5 percent chromic acid solution. Use of these techniques has permitted detailed studies of the microstructures of bismuth-antimony single
SITE CHARACTERIZATION OF A CHROMIUM SOURCE AREA AT THE USCG SUPPORT CENTER, ELIZABETH CITY, NC
The chrome source area is located beneath an old electroplating shop at the United States Coast Guard Support Center near Elizabeth City, NC . This electroplating shop was in
use for approximately 30 years until 1984 and was the source of discharges of chromic and sulfuric...
SITE CHARACTERIZATION OF A CHROMIUM SOURCE AREA AT THE USGS SUPPORT CENTER, ELIZABETH CITY, NC
Chromic and sulfuric acid wastes had discharged through a hole in the concrete floor of a chrome-plating shop located within a hangar at the U.S. Coast Guard Support Center near Elizabeth City, North Carolina and infiltrated the soils and groundwater beneath the shop. Following i...
40 CFR 63.11412 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... ore from trivalent to hexavalent chromium. Sodium chromate means Na2CrO4. It is produced by roasting...: Chromium Compounds Other Requirements and Information § 63.11412 What definitions apply to this subpart... matter loadings. Chromic acid means chromium trioxide (CrO3). It is produced by the electrolytic reaction...
40 CFR 63.11412 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... ore from trivalent to hexavalent chromium. Sodium chromate means Na2CrO4. It is produced by roasting...: Chromium Compounds Other Requirements and Information § 63.11412 What definitions apply to this subpart... matter loadings. Chromic acid means chromium trioxide (CrO3). It is produced by the electrolytic reaction...
40 CFR 63.11412 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... ore from trivalent to hexavalent chromium. Sodium chromate means Na2CrO4. It is produced by roasting...: Chromium Compounds Other Requirements and Information § 63.11412 What definitions apply to this subpart... matter loadings. Chromic acid means chromium trioxide (CrO3). It is produced by the electrolytic reaction...
21 CFR 73.1326 - Chromium hydroxide green.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Chromium hydroxide green. 73.1326 Section 73.1326... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1326 Chromium hydroxide green. (a) Identity. (1) The color additive chromium hydroxide green is principally hydrated chromic sesquioxide (Cr2O3·XH2O...
Allameh, Sayed Kamaleddin; Soofiani, Nasrollah Mahboobi; Pourreza, Javad
2007-10-15
The present research carried out to measure digestible (DE) and Metabolizable Energy (ME) for fishmeal and soybean meal in rainbow trout with two different sizes (120 and 220 g mean body weights). DE and ME are evaluation systems for feedstuffs and also, necessary for diet formulation. The fishes were maintained in metabolic chamber with single ingredient assay of feeding and chromic oxide (Cr2O3) was used as an external marker using total fecal collection method. Gross energy and chromic oxide values measured in feces, fishmeal and soybean meal. The results indicated that DE offishmeal was 3700 and 3591 kcal kg(-1) in 120 and 220 g body weight rainbow trout, respectively. Soybean meal had 3004 and 2889 kcal kg(-1) respectively. Calculated ME from DE were 3204 and 3110 kcal kg(-1) for fishmeal and 2601 and 2502 kcal kg(-1) for soybean meal in 120 and 220 g rainbow trout, respectively. The results showed that rainbow trout can utilize fishmeal more efficiently than soybean meal.
Advances in Suture Material for Obstetric and Gynecologic Surgery
Greenberg, James A; Clark, Rachel M
2009-01-01
Despite millennia of experience with wound closure biomaterials, no study or surgeon has yet identified the perfect suture for all situations. Tissue characteristics, tensile strength, reactivity, absorption rates, and handling properties should be taken into account when selecting a wound closure suture. This review discusses the wound healing process and the biomechanical properties of currently available suture materials to better understand how to choose suture material in obstetrics and gynecology. PMID:19826572
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
Ectocranial suture fusion in primates: pattern and phylogeny.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2014-03-01
Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences. Copyright © 2013 Wiley Periodicals, Inc.
Sclera-directed knot technique for securing an encircling band in retinal surgery.
Bartov, E; Ginsburg, L H; Ashkenazi, I; Treister, G
1991-10-01
The protruding ends of sutures used to secure the ends of the silicone rubber band placed during many retinal surgical procedures may cause postsurgical irritation, since with presently used suturing techniques, the knot of the suture remains on top of the band, facing the conjunctiva. We describe a suturing technique which, by inverting the band when suturing its ends and then allowing the band to return to its original position, places the knot on the undersurface of the band, against the sclera. Thus, no protruding suture ends are left facing the conjunctiva and the irritation resulting from such a protrusion is averted.
Mechanical model of suture joints with fibrous connective layer
NASA Astrophysics Data System (ADS)
Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning
2018-02-01
A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.
da Rosa, Fernando William Figueiredo; Pohl, Pedro Henrique Isoldi; Mader, Ana Maria Amaral Antônio; de Paiva, Carla Peluso; dos Santos, Aline Amaro; Bianco, Bianca; Rodrigues, Luciano Miller Reis
2015-01-01
ABSTRACT Objective To evaluate inflammatory reaction, fibrosis and neovascularization in dural repairs in Wistar rats using four techniques: simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Methods Thirty Wistar rats were randomized in five groups: the first was the control group, submitted to dural tear only. The others underwent durotomy and simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Animals were euthanized and the spine was submitted to histological evaluation with a score system (ranging from zero to 3) for inflammation, neovascularization and fibrosis. Results Fibrosis was significantly different between simple suture and silicon mesh (p=0.005) and between simple suture and mesh with suture (p=0.015), showing that fibrosis is more intense when a foreign body is used in the repair. Bovine membrane was significantly different from mesh plus suture (p=0.011) regarding vascularization. Inflammation was significantly different between simple suture and bovine collagen membrane. Conclusion Silicon mesh, compared to other commercial products available, is a possible alternative for dural repair. More studies are necessary to confirm these findings. PMID:26761555
Effect of human urine on the tensile strength of sutures used for hypospadias surgery.
Kerstein, Ryan L; Sedaghati, Tina; Seifalian, Alexander M; Kang, Norbert
2013-06-01
Hypospadias is the most common congenital condition affecting between 1 in 250 and 300 live births. Even in experienced hands, surgery to repair this congenital defect can have a high complication rate. Wound dehiscence is reported to occur in 5% and fistula formation in 6%-40% depending on technique. The choice of suture material has been shown to affect the complication rate although there is (currently) no consensus about the best suture material to use. Ideally, the sutures used for urethroplasty should be absorbable while maintaining sufficient mechanical strength to support the wounds until they are self-supporting and able to resist urinary flow. Previous studies have compared the effects of human urine on different suture materials especially catgut. However, catgut is now banned in Europe. Our study examined the tensile and breaking strength as well as rate of degradation for four types of absorbable suture now commonly used for hypospadias repairs in the UK. We examined the effect of prolonged storage (up to 27 days) in human urine on 6/0 gauge Vicryl, Vicryl Rapide, Monocryl and polydioxanone (PDS) sutures. These four suture materials are commonly used by the senior plastic consultant surgeon (NK) for hypospadias repairs. 50 mm sections of these suture materials were stored in either urine or saline as control. At specified time points, each suture was placed in a uniaxial load testing machine to assess the stress-strain profile and the mechanical load required to break the suture was measured. Exposure to urine reduced the tensile and breaking strength of all the suture materials tested. PDS demonstrated the greatest resilience. Vicryl Rapide was the weakest suture and degraded completely by day 6. Vicryl and Monocryl had similar degradation profiles, but Vicryl retained more of its tensile strength for longer. There is a balance to be struck between the duration that a suture material must remain in any surgical wound and the risk that it causes foreign body effects. The results of this study suggest that Vicryl has the best characteristics for urethroplasty of the four suture materials tested. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Britt, Rebecca C; Scerbo, Mark W; Montano, Michael; Kennedy, Rebecca A; Prytz, Erik; Stefanidis, Dimitrios
2015-11-01
A spatial secondary task developed by the authors was used to measure the mental workload of the participant when transferring suturing skills from a box simulator to more realistic surgical conditions using a fresh cadaver. We hypothesized that laparoscopic suturing on genuine bowel would be more challenging than on the Fundamentals of Laparoscopic Surgery (FLS)-simulated bowel as reflected in differences on both suturing and secondary task scores. We trained 14 surgical assistant students to FLS proficiency in intracorporeal suturing. Participants practiced suturing on the FLS box for 30 minutes and then were tested on both the FLS box and the bowel of a fresh cadaver using the spatial, secondary dual-task conditions developed by the authors. Suturing times increased by >333% when moving from the FLS platform to the cadaver F(1,13) = 44.04, P < .001. The increased completion times were accompanied by a 70% decrease in secondary task scores, F(1,13) = 21.21, P < .001. The mental workload associated with intracorporeal suturing increases dramatically when trainees transfer from the FLS platform to human tissue under more realistic conditions of suturing. The increase in mental workload is indexed by both an increase in suturing times and a decrease in the ability to attend to the secondary task. Copyright © 2015 Elsevier Inc. All rights reserved.
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Development of a needle driver with multiple degrees of freedom for neonatal laparoscopic surgery.
Ishimaru, Tetsuya; Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-07-01
The aims of this study were to develop a thin needle driver with multiple degrees of freedom and to evaluate its efficacy in multidirectional suturing compared with a conventional needle driver. The tip (15 mm) of the novel user-friendly needle driver (3.5 mm in diameter) has three degrees of freedom for grasping, rotation, and deflection. Six pediatric surgeons performed two kinds of suturing tasks in a dry box: three stitches in continuous suturing that were perpendicular or parallel to the insertion direction of the instrument, first using the novel instrument, then using a conventional instrument, and finally using the novel instrument again. The accuracy of insertion and exit compared with the target points and the procedure time were measured. In the conventional and novel procedures the mean gaps from the insertion point to the target in perpendicular suturing were 0.8 mm and 0.7 mm, respectively; in parallel suturing they were 0.8 mm and 0.6 mm, respectively. The mean gaps from the exit point to the target in perpendicular suturing were 0.6 mm and 0.6 mm for conventional and novel procedures, respectively; in parallel suturing they were 0.6 mm and 0.8 mm, respectively. The procedure time for perpendicular suturing was 33 seconds and 64 seconds for conventional and novel procedures, respectively (P=.02); for parallel suturing it was 114 seconds and 91 seconds, respectively. Our novel needle driver maintained accuracy of suturing; parallel suturing with the novel driver may be easier than with the conventional one.
Strain in the Braincase and Its Sutures During Function
Herring, Susan W.; Teng, Shengyi
2010-01-01
The skull is distinguished from other parts of the skeleton by its composite construction. The sutures between bony elements provide for interstitial growth of the cranium, but at the same time they alter the transmission of stress and strain through the skull. Strain gages were bonded to the frontal and parietal bones of miniature pigs and across the interfrontal, interparietal and coronal sutures. Strains were recorded 1) during natural mastication in conjunction with electromyographic activity from the jaw muscles and 2) during stimulation of various cranial muscles in anesthetized animals. Vault sutures exhibited vastly higher strains than did the adjoining bones. Further, bone strain primarily reflected torsion of the braincase set up by asymmetrical muscle contraction; the tensile axis alternated between +45° and −45° depending on which diagonal masseter/temporalis pair was most active. However, suture strains were not related to overall torsion but instead were responses to local muscle actions. Only the coronal suture showed significant strain (tension) during jaw opening; this was caused by the contraction of neck muscles. All sutures showed strain during jaw closing, but polarity depended on the pattern of muscle usage. For example, masseter contraction tensed the coronal suture and the anterior part of the interfrontal suture, whereas the temporalis caused compression in these locations. Peak tensile strains were larger than peak compressive strains. Histology suggested that the skull is bent at the sutures, with the ectocranial surface tensed and the endocranial surface predominantly compressed. Collectively, these results indicate that skulls with patent sutures should be analyzed as complexes of independent parts rather than solid structures. PMID:10918130
Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism
Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S
2013-01-01
Aims In a previous study, we proposed that corneal topography performed 30–40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. Methods 10/0 nylon interrupted sutures were placed, to secure the graft–host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30–40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4–6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Results Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). Conclusion SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty. PMID:23743526
Singh, Ashima; Bartsch, Sarah M; Muder, Robert R; Lee, Bruce Y
2014-08-01
While the persistence of high surgical site infection (SSI) rates has prompted the advent of more expensive sutures that are coated with antimicrobial agents to prevent SSIs, the economic value of such sutures has yet to be determined. Using TreeAge Pro, we developed a decision analytic model to determine the cost-effectiveness of using antimicrobial sutures in abdominal incisions from the hospital, third-party payer, and societal perspectives. Sensitivity analyses systematically varied the risk of developing an SSI (range, 5%-20%), the cost of triclosan-coated sutures (range, $5-$25/inch), and triclosan-coated suture efficacy in preventing infection (range, 5%-50%) to highlight the range of costs associated with using such sutures. Triclosan-coated sutures saved $4,109-$13,975 (hospital perspective), $4,133-$14,297 (third-party payer perspective), and $40,127-$53,244 (societal perspective) per SSI prevented, when a surgery had a 15% SSI risk, depending on their efficacy. If the SSI risk was no more than 5% and the efficacy in preventing SSIs was no more than 10%, triclosan-coated sutures resulted in extra expenditure for hospitals and third-party payers (resulting in extra costs of $1,626 and $1,071 per SSI prevented for hospitals and third-party payers, respectively; SSI risk, 5%; efficacy, 10%). Our results suggest that switching to triclosan-coated sutures from the uncoated sutures can both prevent SSIs and save substantial costs for hospitals, third-party payers, and society, as long as efficacy in preventing SSIs is at least 10% and SSI risk is at least 10%.
Shi, Brendan Y; Diaz, Miguel; Belkoff, Stephen M; Srikumaran, Uma
2017-12-01
Obtaining strong fixation in low-density bone is increasingly critical in surgical repair of rotator cuff tears because of the aging population. To evaluate two new methods of improving pullout strength of transosseous rotator cuff repair in low-density bone, we analyzed the effects of 1) using 2-mm suture tape instead of no. 2 suture and 2) augmenting the lateral tunnel with cement. Eleven pairs of osteopenic or osteoporotic cadaveric humeri were identified by dual-energy x-ray absorptiometry. One bone tunnel and one suture were placed in the heads of 22 specimens. Five randomly selected pairs were repaired with no. 2 suture; the other six pairs were repaired with 2-mm suture tape. One side of each pair received lateral tunnel cement augmentation. Specimens were tested to suture pullout. Data were fitted to multivariate models that accounted for bone mineral density and other specimen characteristics. Two specimens were excluded because of knot-slipping during testing. Use of suture tape versus no. 2 suture conferred a 75-N increase (95% CI: 37, 113) in pullout strength (P<0.001). Cement augmentation conferred a 42-N improvement (95% CI: 10, 75; P=0.011). Other significant predictors of pullout strength were age, sex, and bone mineral density. We show two methods of improving the fixation strength of transosseous rotator cuff repairs in low-density bone: using 2-mm suture tape instead of no. 2 suture and augmenting the lateral tunnel with cement. These methods may improve the feasibility of transosseous repairs in an aging patient population. Copyright © 2017 Elsevier Ltd. All rights reserved.
Comparing the Tolerability of a Novel Wound Closure Device Using a Porcine Wound Model
Townsend, Katy L.; Akeroyd, Jen; Russell, Duncan S.; Kruzic, Jamie J.; Robertson, Bria L.; Lear, William
2018-01-01
Objective: To compare the tolerability and mechanical tensile strength of acute skin wounds closed with nylon suture plus a novel suture bridge device (SBD) with acute skin wounds closed with nylon suture in a porcine model. Approach: Four Yucatan pigs each received 12 4.5 cm full-thickness incisions that were closed with 1 of 4 options: Suture bridge with nylon, suture bridge with nylon and subdermal polyglactin, nylon simple interrupted, and nylon simple interrupted with subdermal polyglactin. Epithelial reaction, inflammation, and scarring were examined histologically at days 10 and 42. Wound strength was examined mechanically at days 10 and 42 on ex vivo wounds from euthanized pigs. Results: Histopathology in the suture entry/exit planes showed greater dermal inflammation with a simple interrupted nylon suture retained for 42 days compared with the SBD retained for 42 days (p < 0.03). While tensile wound strength in the device and suture groups were similar at day 10, wounds closed with the devices were nearly 8 times stronger at day 42 compared with day 10 (p < 0.001). Innovation: A novel SBD optimized for cutaneous wound closure that protects the skin surface from suture strands, forms a protective bridge over the healing wound edges, and knotlessly clamps sutures. Conclusion: This study suggests that the use of a SBD increases the tolerability of nylon sutures in porcine acute skin wound closures allowing for prolonged mechanical support of the wound. For slow healing wounds, this may prevent skin wound disruption, such as edge necrosis and dehiscence. PMID:29892494
Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism.
Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S
2013-09-01
In a previous study, we proposed that corneal topography performed 30-40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. 10/0 nylon interrupted sutures were placed, to secure the graft-host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30-40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4-6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty.
Cystoscopic suture removal by Holmium-YAG laser after Burch procedure
Karaşahin, Emre Kazım; Esin, Sertaç; Alanbay, İbrahim; Ercan, Mutlu Cihangir; Mutlu, Erol; Başer, İskender; Basal, Şeref
2011-01-01
Burch colposuspension remains one of the successful operations performed for stress incontinence. Accidental suturing of the bladder wall during the procedure or subsequent erosion may lead to lower urinary tract symptoms. Diagnosis and management of these sutures indicate precise evaluation for which a 70 degree cystoscope is used. In selected cases, Holmium-YAG laser may enable us to manage long-standing, encrustated neglected sutures. Here we would like to report successful removal of intravesical sutures using the Holmium-YAG laser. PMID:24591960
Ripcord adjustable suture technique for use in strabismus surgery.
Coats, D K
2001-09-01
Adjustable sutures in strabismus surgery may be difficult or impossible in poorly cooperative patients. An adjunct suture technique that allows a 1-step, all-or-nothing, preprogrammed adjustment in patients not considered good candidates for standard postoperative adjustable sutures is described. Twelve patients underwent adjustable strabismus surgery using the ripcord technique. Six patients had unacceptable alignment after surgery. In 5 of these, alignment was successfully adjusted. The ripcord adjustable suture technique is effective and is well tolerated by patients.
The suspension (Frost) suture: experience and applications.
Connolly, Karen L; Albertini, John G; Miller, Christopher J; Ozog, David M
2015-03-01
The Frost suture is a well-known surgical technique for providing upward tension on the lower lid to prevent or correct ectropion after surgical interventions in the periorbital area. Despite its relatively common use, comprehensive information on executing this technique is not readily available. To review eyelid anatomy, indications, and proper technique for performing the Frost suture, as well as potential complications. A review of the literature on Frost sutures was performed. Cadaveric dissection was performed to demonstrate placement of the Frost suture. The Frost suture is a useful method to reduce the risk of ectropion after surgery near the lower eyelid. Downward pull on the lid can occur with normal wound contracture even if ectropion is not present with the initial repair, reinforcing the need for preventive measures. Potential complications of this technique include superficial skin erosion of the upper lid, corneal abrasion, and blockage of the field of vision while the suture is in place.
Poe, Demelza J
2011-01-01
A fused/closed basilar suture is usually treated as an indication of old age in great apes. A sample, drawn from a variety of sources, of known-aged captive great ape skeletons was analyzed to test the usefulness of using the basilar suture to categorize adult skeletons as either "adult" or "old adult". The state of closure of the basilar suture was examined in 30 chimpanzees, 19 gorillas, and 15 orangutans, all of known age. The results show that the basilar suture demonstrates a high level of uniformity in rate of closure and is closed at an early age in virtually all known-aged individuals. Thus, an old adult category most likely includes individuals who are, in fact, relatively young. This indicates that using the basilar suture as a means to classify individual skeletons as adult or old adult is very imprecise. The homogenous nature of basilar suture closure appears to prevent meaningful application of suture status for categorizing adult ape skeletons by age groups.
3D Printed Anchoring Sutures for Permanent Shaping of Tissues.
Wei, Wei; Li, Yuxiao; Yang, Huazhe; Nassab, Reza; Shahriyari, Fatemeh; Akpek, Ali; Guan, Xiaofei; Liu, Yanhui; Taranejoo, Shahrouz; Tamayol, Ali; Zhang, Yu Shrike; Khademhosseini, Ali; Jang, Hae Lin
2017-12-01
Sutures are one of the most widely used devices for adhering separated tissues after injury or surgery. However, most sutures require knotting, which can create a risk of inflammation, and can act as mechanically weak points that often result in breakage and slipping. Here, an anchoring suture is presented with a design that facilitates its propagation parallel to the suturing direction, while maximizing its resistive force against the opposite direction of external force to lock its position in tissues. Different microstructures of suture anchors are systematically designed using orthogonal arrays, and selected based on shape factors associated with mechanical strength. 3D printing is used to fabricate different types of hollow microstructured suture anchors, and optimize their structure for the effective shaping of tissues. To define the structural design for fixing tissues, the maximum force required to pull 3D printed anchors in different directions is examined with tissues. The tissue reshaping function of suture anchors is further simulated ex vivo by using swine ear, nose, and skin, and bovine muscle tendon. This study provides advantages for building functional sutures that can be used for permanently reshaping tissues with enhanced mechanical strength, eliminating the need for knotting to improve surgical efficiency. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liss, S. A.; Ashton, N. K.; Brown, R. S.
A new acoustic transmitter (AT; cylindrical, 0.7 g in air, 24.2×5.0 mm, up to 365 d battery life) was developed to monitor age-0 sturgeon; however, an implantation technique is critical to provide guidance for its use in field research. The goal of this study was to evaluate four implantation techniques by assessing transmitter retention, survival, growth, and wound healing variables. White sturgeon (Acipenser transmontanus; n = 150, 35–116 g, 182–289 mm fork length) were separated into five treatments: 1) unmarked, 2) flank incision with one suture, 3) flank incision without a suture, 4) offline incision with one suture, and 5)more » offline incision without a suture. Tagged fish were implanted with a non-functioning AT and all fish were held for 28 days. There was 100% transmitter retention and no difference in survival or growth (by 14 d post-implantation) among treatments. Sutured treatments had greater inflammation and presence of ulceration and water mold than non-sutured. Offline incision fish were more susceptible to red vein aggregation than flank incision fish. Non-sutured treatments had greater openness than sutured, but only during the first 14 d post-implantation. The flank incision without a suture technique is recommended.« less
Sundararaj, Sharath; Slusarewicz, Paul; Brown, Matt; Hedman, Thomas
2017-11-01
The most common mode of surgical repair of ruptured tendons and ligaments involves the use of sutures for reattachment. However, there is a high incidence of rerupture and repair failure due to pulling out of the suture material from the damaged connective tissue. The main goal of this research was to achieve a localized delivery of crosslinking agent genipin (GP) from rapid-release biodegradable coatings on sutures, for strengthening the repair of ruptured connective tissue. Our hypothesis is that GP released from the suture coating will lead to exogenous crosslinking of native connective tissue resulting in beneficial effects on clinically relevant mechanical parameters such as tear resistance, tissue strength, and energy required to rupture the tissue (toughness). Sutures were successfully coated with a biodegradable polymer layer loaded with the crosslinking agent genipin, without compromising the mechanical properties of the suture. The rapid-release of genipin was achieved under both in vitro and ex vivo conditions. Exogenous crosslinking using these genipin releasing sutures was demonstrated using equine tendons. The tendons treated with genipin releasing sutures showed significant improvement in failure load, energy required for pull-out failure, and stiffness. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2199-2205, 2017. © 2016 Wiley Periodicals, Inc.
Johnson, Amy S; Ellers, Olaf; Lemire, Jim; Minor, Melissa; Leddy, Holly A
2002-02-07
The shape of sea urchins may be determined mechanically by patterns of force analogous to those that determine the shape of a water droplet. This mechanical analogy implies skeletal flexibility at the time of growth. Although comprised of many rigid calcite plates, sutural collagenous ligaments could confer such flexibility if the sutures between plates loosened and acted as joints at the time of growth. We present experimental evidence of such flexibility associated with weight gain and growth. Over 13-, 4-, and 2-week periods, fed urchins (Strongylocentrotus droebachiensis) gained weight and developed looser sutures than unfed urchins that maintained or lost weight. Further, skeletons of fed urchins force-relaxed more than did those of unfed urchins and urchins with loose sutures force-relaxed more than those with tight sutures. Urchins (Strongylocentrotus franciscanus) fed for two and a half weeks, gained weight, also had looser skeletons and deposited calcite at sutural margins, whereas unfed ones did not. In field populations of S. droebachiensis the percentage having loose sutures varied with urchin diameter and reflected their size-specific growth rate. The association between feeding, weight gain, calcite deposition, force relaxation and sutural looseness supports the hypothesis that urchins deform flexibly while growing, thus determining their drop-like shapes.
Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study
Ranganath, V.; Nichani, Ashish Sham
2013-01-01
Purpose The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. Methods Three suture materials (polyglycolic acid [PGA], polyglactin [PG] 910, and poly (glycolide-co-є-caprolactone) [PGC]) were used in 4-0 and 5-0 gauges. 210 suture samples (35 of each material and gauge) were used. All of the samples were tested preimmersion and 1 hour and 1, 3, 7, 10, and 14 days postimmersion. The tensile strength of each suture material and gauge was assessed. The point of breakage and the resorption pattern of the sutures were also assessed. Results During the first 24 hours of immersion, all 4-0 and 5-0 samples of PGA, PG 910, and PGC maintained their initial tensile strength. At baseline (preimmersion), there was a statistically significant (P<0.001) difference in the tensile strengths between the 4-0 and 5-0 gauge of PGA, PG 910, and PGC. PGA 4-0 showed the highest tensile strength until day 10. At 7 days, all the 4-0 sutures of the three materials had maintained their tensile strength with PGA 4-0 having significantly greater (P=0.003) tensile strength compared to PG. Conclusions 4-0 sutures are stronger and have greater tensile strength than 5-0 sutures. The PGA 4-0 suture showed the highest tensile strength at the end of day 10. PMID:23837127
Heterochrony and patterns of cranial suture closure in hystricognath rodents
Wilson, Laura A B; Sánchez-Villagra, Marcelo R
2009-01-01
Sutures, joints that allow one bone to articulate with another through intervening fibrous connective tissue, serve as major sites of bone expansion during postnatal craniofacial growth in the vertebrate skull and represent an aspect of cranial ontogeny which may exhibit functional and phylogenetic correlates. Suture evolution among hystricognath rodents, an ecologically diverse group represented here by 26 species, is examined using sequence heterochrony methods, i.e. event pairing and parsimov. Although minor nuances in suture closure sequence exist between species, the overall sequence was found to be conserved both across the hystricognath group and, to an increasing degree, within selected clades. At species level, suture closure pattern exhibited a significant positive correlation with patterns previously reported for hominoids. Patterns for most clades revealed the first sutures to close are those contacting the exoccipital, interparietal, and palatine bones. Heterochronic shifts were found along 19 of 35 branches within the hystricognath phylogeny. The number of shifts per node ranged from one to seven events and, overall, involved 21 of 34 suture sites. The topology generated by parsimony analyses of the event pair matrix yielded only one grouping that was congruent with the evolutionary relationships, compiled from morphological and molecular studies, taken as framework. Sutures contacting the exoccipital displayed the highest levels of most complete closure across all species. Level of suture closure is negatively correlated with cranial length (P < 0.05). Differing life history and locomotory strategies are coupled in part with differing suture closure patterns among several species. PMID:19245501
Kearney, C M; Buckley, C T; Jenner, F; Moissonnier, P; Brama, P A J
2014-07-01
Selection of suture material in equine surgery is often based on costs or subjective factors, such as the surgeon's personal experience, rather than objective facts. The amount of objective data available on durability of suture materials with regard to specific equine physiological conditions is limited. To evaluate the effect of various equine physiological and pathological fluids on the rate of degradation of a number of commonly used suture materials. In vitro material testing. Suture materials were exposed in vitro to physiological fluid, followed by biomechanical analysis. Three absorbable suture materials, glycolide/lactide copolymer, polyglactin 910 and polydioxanone were incubated at 37°C for 7, 14 or 28 days in phosphate-buffered saline, equine serum, equine urine and equine peritoneal fluid from an animal with peritonitis. Five strands of each suture material type were tested to failure in a materials testing machine for each time point and each incubation medium. Yield strength, strain and Young's modulus were calculated, analysed and reported. For all suture types, the incubation time had a significant effect on yield strength, percentage elongation and Young's modulus in all culture media (P<0.0001). Suture type was also shown significantly to influence changes in each of yield strength, percentage elongation and Young's modulus in all culture media (P<0.0001). While the glycolide/lactide copolymer demonstrated the highest Day 0 yield strength, it showed the most rapid degradation in all culture media. For each of the 3 material characteristics tested, polydioxanone showed the least variation across the incubation period in each culture medium. The duration of incubation and the type of fluid have significant effects on the biomechanical properties of various suture materials. These findings are important for evidence-based selection of suture material in clinical cases. © 2013 EVJ Ltd.
Microbiology of Explanted Suture Segments from Infected and Noninfected Surgical Patients
Krepel, Candace J.; Marks, Richard M.; Rossi, Peter J.; Sanger, James; Goldblatt, Matthew; Graham, Mary Beth; Rothenburger, Stephen; Collier, John; Seabrook, Gary R.
2013-01-01
Sutures under selective host/environmental factors can potentiate postoperative surgical site infection (SSI). The present investigation characterized microbial recovery and biofilm formation from explanted absorbable (AB) and nonabsorbable (NAB) sutures from infected and noninfected sites. AB and NAB sutures were harvested from noninfected (70.9%) and infected (29.1%) sites in 158 patients. At explantation, devices were sonicated and processed for qualitative/quantitative bacteriology; selective sutures were processed for scanning electron microscopy (SEM). Bacteria were recovered from 85 (53.8%) explanted sites; 39 sites were noninfected, and 46 were infected. Suture recovery ranged from 11.1 to 574.6 days postinsertion. A significant difference in mean microbial recovery between noninfected (1.2 isolates) and infected (2.7 isolates) devices (P < 0.05) was noted. Staphylococcus epidermidis, Staphylococcus aureus, coagulase-negative staphylococci (CNS), Peptostreptococcus spp., Bacteroides fragilis, Escherichia coli, Enterococcus spp., Pseudomonas aeruginosa, and Serratia spp. were recovered from infected devices, while commensal skin flora was recovered from noninfected devices. No significant difference in quantitative microbial recovery between infected monofilament and multifilament sutures was noted. Biofilm was present in 100% and 66.6% of infected and noninfected devices, respectively (P < 0.042). We conclude that both monofilament and braided sutures provide a hospitable surface for microbial adherence: (i) a significant difference in microbial recovery from infected and noninfected sutures was noted, (ii) infected sutures harbored a mixed flora, including multidrug-resistant health care-associated pathogens, and (iii) a significant difference in the presence or absence of a biofilm in infected versus noninfected explanted devices was noted. Further studies to document the benefit of focused risk reduction strategies to minimize suture contamination and biofilm formation postimplantation are warranted. PMID:23175247
Guo, Jiao; Pan, Ling-Hui; Li, Yun-Xi; Yang, Xiang-Di; Li, Le-Qun; Zhang, Chun-Yan; Zhong, Jian-Hong
2016-03-01
Surgical site infection (SSI) is the third most frequent type of nosocomial infections. Triclosan-coated sutures are often used to reduce the risk of SSI, but studies examining this have given conflicting results. Therefore, this meta-analysis was performed to assess the efficacy of triclosan-coated sutures for reducing risk of SSI in adults. PubMed, EMBASE, Google Scholar, and ClinicalTrials.gov were searched to identify randomized clinical trials evaluating triclosan-coated sutures for preventing SSI on patients 18 y or older. Thirteen randomized clinical trials involving 5256 participants were included. Triclosan-coated sutures were associated with lower risk of SSI than uncoated sutures across all surgeries (risk ratio [RR] 0.76, 95% confidence interval [CI] 0.65-0.88, P < 0.001). Similar proportions of patients experienced wound dehiscence with either type of suture (RR 0.97, 95% CI 0.49-1.89, P = 0.92). Subgroup analysis showed lower risk of SSI with triclosan-coated sutures in abdominal surgeries (RR 0.70, 95% CI 0.50-0.99, P = 0.04) and group with prophylactic antibiotic (RR 0.79, 95% CI 0.63-0.99, P = 0.04). However, such risk reduction was not observed in cardiac surgeries, breast surgeries, or group without prophylactic antibiotic. Triclosan-coated sutures can decrease the incidence of SSI in abdominal surgeries and might not interfere with wound healing process. Nevertheless, further studies are needed to examine whether triclosan-coated sutures are effective at preventing SSI in non-abdominal surgeries and to further study the interaction of antibiotic prophylaxis with triclosan-coated sutures. Copyright © 2016 Elsevier Inc. All rights reserved.
Chalon, A; Favre, J; Piotrowski, B; Landmann, V; Grandmougin, D; Maureira, J-P; Laheurte, P; Tran, N
2018-06-01
Implantation of a Left Ventricular Assist Device (LVAD) may produce both excessive local tissue stress and resulting strain-induced tissue rupture that are potential iatrogenic factors influencing the success of the surgical attachment of the LVAD into the myocardium. By using a computational simulation compared to mechanical tests, we sought to investigate the characteristics of stress-induced suture material on porcine myocardium. Tensile strength experiments (n = 8) were performed on bulk left myocardium to establish a hyperelastic reduced polynomial constitutive law. Simultaneously, suture strength tests on left myocardium (n = 6) were performed with a standard tensile test setup. Experiments were made on bulk ventricular wall with a single U-suture (polypropylene 3-0) and a PTFE pledget. Then, a Finite Element simulation of a LVAD suture case was performed. Strength versus displacement behavior was compared between mechanical and numerical experiments. Local stress fields in the model were thus analyzed. A strong correlation between the experimental and the numerical responses was observed, validating the relevance of the numerical model. A secure damage limit of 100 kPa on heart tissue was defined from mechanical suture testing and used to describe numerical results. The impact of suture on heart tissue could be accurately determined through new parameters of numerical data (stress diffusion, triaxiality stress). Finally, an ideal spacing between sutures of 2 mm was proposed. Our computational model showed a reliable ability to provide and predict various local tissue stresses created by suture penetration into the myocardium. In addition, this model contributed to providing valuable information useful to design less traumatic sutures for LVAD implantation. Therefore, our computational model is a promising tool to predict and optimize LVAD myocardial suture. Copyright © 2018 Elsevier Ltd. All rights reserved.
Load response and gap formation in a single-row cruciate suture rotator cuff repair.
Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C
2017-06-01
Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.
Renko, Marjo; Paalanne, Niko; Tapiainen, Terhi; Hinkkainen, Matti; Pokka, Tytti; Kinnula, Sohvi; Sinikumpu, Juha-Jaakko; Uhari, Matti; Serlo, Willy
2017-01-01
Surgical site infections (SSIs) are a pervasive problem in surgery. Sutures coated or impregnated with triclosan might reduce the occurrence of SSIs, but evidence of their efficacy is limited, especially in children. We designed a randomised, double-blind, controlled trial in patients who underwent elective or daytime emergency surgery at Oulu University Hospital (Oulu, Finland). We included children younger than 18 years staying in the paediatric surgery and orthopaedics ward for any elective or emergency surgery during the daytime and with anticipated use of absorbing sutures. Children were randomly allocated (1:1) to receive either triclosan-containing sutures or ordinary absorbing sutures. The primary outcome was the occurrence of superficial or deep surgical site infections according to the Centers for Disease Control and Prevention criteria within 30 days after surgery. The primary analysis was with modified intention to treat. This trial is registered at ClinicalTrials.gov, number NCT01220700. Between September, 2010, and December, 2014, 1633 children were recruited. In the modified intention-to-treat group, SSIs occurred in 20 (3%) of 778 patients allocated to receive triclosan-containing sutures and in 42 (5%) of 779 patients allocated to receive control sutures (risk ratio 0·48, 95% CI 0·28-0·80). To prevent one SSI, triclosan-containing sutures had to be used in 36 children (95% CI 21-111). One patient died from suspected mitochondrial disease; no other expected or unexpected adverse events were reported in either of the groups. Use of triclosan-containing sutures effectively reduced the occurrence of all SSIs compared with normal sutures. The results accord with the results of meta-analyses of previous studies in adults. Use of triclosan-containing sutures is a simple way to reduce SSIs in children. The Alma and K A Snellman Foundation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Waldrop, Norman E; Wijdicks, Coen A; Jansson, Kyle S; LaPrade, Robert F; Clanton, Thomas O
2012-11-01
Despite the popularity of the Broström procedure for secondary repair of chronic lateral ankle instability, there have been no biomechanical studies reporting on the strength of this secondary repair method, whether using suture fixation or suture anchors. The purpose of our study was to perform a biomechanical comparison of the ultimate load to failure and stiffness of the traditional Broström technique using only a suture repair compared with a suture anchor repair of the anterior talofibular ligament (ATFL) at time zero. We believed that fixation strength of the suture anchor repair would be closer to the strength of the native ligament and allow more aggressive rehabilitation. Controlled laboratory study. Twenty-four fresh-frozen cadaveric ankles were randomly divided into 4 groups of 6 specimens. One group was an intact control group, and the other groups consisted of the traditional Broström and 2 suture anchor modifications (suture anchors in talus or fibula) of the Broström procedure. The specimens were loaded to failure to determine the strength and stiffness of each construct. In load-to-failure testing, ultimate failure loads of the Broström (68.2 ± 27.8 N; P = .013), suture anchor fibula (79.2 ± 34.3 N; P = .037), and suture anchor talus (75.3 ± 45.6 N; P = .027) repairs were significantly lower than that of the intact (160.9 ± 72.2 N) ATFL group. Stiffness of the Broström (6.0 ± 2.5 N/mm; P = .02), suture anchor fibula (6.8 N/mm ± 2.7; P = .05), and suture anchor talus (6.6 N/mm ± 4.0; P = .04) repairs were significantly lower than that of the intact (12.4 N/mm ± 4.1 N/mm) ATFL group. The 3 repair groups were not significantly different from each other, but all 3 were substantially lower in strength and stiffness when compared to the intact ATFL. The use of suture anchors to repair the ATFL produces a repair that can withstand loads to failure similar to the suture-only Broström repair. However, all 3 repair groups were much weaker than the intact, uninjured ATFL. Biomechanically, the results show that both suture anchor and direct suture repair of the ATFL provide similar strength and stiffness. Unfortunately, these methods provide less than half the strength and stiffness of the native ATFL at time zero. As a result, regardless of the repair method, it is necessary to sufficiently protect the repair to avoid premature failure.
Petrut, Bogdan; Hogea, Maximiliam; Fetica, Bogdan; Kozan, Andrei; Feflea, Dragos; Sererman, Gabriel; Goezen, Ali Serdar; Rassweiler, Jens
2013-01-01
The laparoscopic approach in urological surgery demands a high degree of skill in intracorporeal suturing and knot tying. In an effort to reduce the amount of time required to perform a suture, new materials have been developed that through selfanchorage distribute tension more evenly across the suture and also eliminate the need of knot tying. The goal of this study was to assess the in vivo tissue response to a novel material (V-Loc tm; Covidien) in comparison to established materials (Vicryl, PDS II), in the case of bladder suturing, in a rat model. The study included 48 male Wistar rats. All underwent a median abdominal incision, with a 1cm cystotomy, followed by a running suture. The suture material used was either V-Loc absorbable self anchoring thread, Vicryl threaded absorbable suture or monofilament absorbable suture. The abdominal cavity and the bladder suture were macroscopically evaluated at the rats' scheduled death at 3 and 6 weeks. The bladder wall was microscopically assessed by a pathologist, with regard to tissue reaction and suture material degradation. All rats survived the procedure, with the abdominal scar fully healed at week 2. There were no signs of infection or lithiasis during the observation. Macroscopically, at 3 weeks, the suture material was recognizable and visible in all cases, with special mention that the V-Loc thread was considerably more rigid, retaining its shape almost entirely, and provoked more adhesion of the surrounding tissue. At 6 weeks, the suture was indistinguishable in the bladder wall in the case of monofilament absorbable material, barely visible in the case of Vicryl, while the aspect of the V-Loc suture resembled the one at 3 weeks, with the material still clearly visible in the bladder wall, shape almost entirely maintained, and surrounding tissue adherence. Microscopically, at 3 weeks and 6 weeks, all bladder walls examined had regained their structure. At 3 weeks, the monofilament absorbable suture showed intense tissue reaction, with the material already in phagocytosis; at 6 weeks, no clear evidence of leftover material was observed. At 3 weeks, the Vicryl material showed moderate tissue reaction, with phagocytosis initiated between the strands of the material; at 6 weeks, the material was almost entirely absorbed, but with a clear leftover tissue reaction. In the case of the V-Loc suture, due to the hardness of the thread, the material itself could not be cut for analysis with the bladder wall, and the examination could only involve the bladder wall and marks of the thread. Thus, the tissue reaction was minimal, as was the presence of phagocytes at the suture site. The material showed little, if any, signs of absorption after 6 weeks. The materials tested all proved equally effective in suturing the bladder wall in a rat model. However, the novel barbed thread proved a consistently low in-vivo absorption rate, while maintaining its rigidity over time. More research is needed to assess the possible clinical implications of these findings.
PETRUT, BOGDAN; HOGEA, MAXIMILIAM; FETICA, BOGDAN; KOZAN, ANDREI; FEFLEA, DRAGOS; SERERMAN, GABRIEL; GOEZEN, ALI SERDAR; RASSWEILER, JENS
2013-01-01
Aim The laparoscopic approach in urological surgery demands a high degree of skill in intracorporeal suturing and knot tying. In an effort to reduce the amount of time required to perform a suture, new materials have been developed that through selfanchorage distribute tension more evenly across the suture and also eliminate the need of knot tying. The goal of this study was to assess the in vivo tissue response to a novel material (V-Loc tm; Covidien) in comparison to established materials (Vicryl, PDS II), in the case of bladder suturing, in a rat model. Methods The study included 48 male Wistar rats. All underwent a median abdominal incision, with a 1cm cystotomy, followed by a running suture. The suture material used was either V-Loc absorbable self anchoring thread, Vicryl threaded absorbable suture or monofilament absorbable suture. The abdominal cavity and the bladder suture were macroscopically evaluated at the rats’ scheduled death at 3 and 6 weeks. The bladder wall was microscopically assessed by a pathologist, with regard to tissue reaction and suture material degradation. Results All rats survived the procedure, with the abdominal scar fully healed at week 2. There were no signs of infection or lithiasis during the observation. Macroscopically, at 3 weeks, the suture material was recognizable and visible in all cases, with special mention that the V-Loc thread was considerably more rigid, retaining its shape almost entirely, and provoked more adhesion of the surrounding tissue. At 6 weeks, the suture was indistinguishable in the bladder wall in the case of monofilament absorbable material, barely visible in the case of Vicryl, while the aspect of the V-Loc suture resembled the one at 3 weeks, with the material still clearly visible in the bladder wall, shape almost entirely maintained, and surrounding tissue adherence. Microscopically, at 3 weeks and 6 weeks, all bladder walls examined had regained their structure. At 3 weeks, the monofilament absorbable suture showed intense tissue reaction, with the material already in phagocytosis; at 6 weeks, no clear evidence of leftover material was observed. At 3 weeks, the Vicryl material showed moderate tissue reaction, with phagocytosis initiated between the strands of the material; at 6 weeks, the material was almost entirely absorbed, but with a clear leftover tissue reaction. In the case of the V-Loc suture, due to the hardness of the thread, the material itself could not be cut for analysis with the bladder wall, and the examination could only involve the bladder wall and marks of the thread. Thus, the tissue reaction was minimal, as was the presence of phagocytes at the suture site. The material showed little, if any, signs of absorption after 6 weeks. Conclusion The materials tested all proved equally effective in suturing the bladder wall in a rat model. However, the novel barbed thread proved a consistently low in-vivo absorption rate, while maintaining its rigidity over time. More research is needed to assess the possible clinical implications of these findings. PMID:26527981
NDCEE Annual Technologies Publication
2003-04-01
Engineering Center TBP Thermophilic (Biological) Process TCP Trivalent chromium pretreatment 3-D Three-dimensional TNT 2,4,6 trinitrotoluene TTU Transit-Time...to be able to restore worn, improperly machined or salvaged service parts. Trivalent Chromium Plating: This process eliminates the use of chromic...acid, thereby reducing health risks to operators. Trivalent chromium forms insoluble mineral precipitates in groundwater, which eliminates the chemical
Robinson, James R; Frank, Evelyn G; Hunter, Alan J; Jermin, Paul J; Gill, Harinderjit S
2018-03-01
A simple suture technique in transosseous meniscal root repair can provide equivalent resistance to cyclic load and is less technically demanding to perform compared with more complex suture configurations, yet maximum yield loads are lower. Various suture materials have been investigated for repair, but it is currently not clear which material is optimal in terms of repair strength. Meniscal root anatomy is also complex; consisting of the ligamentous mid-substance (root ligament), the transition zone between the meniscal body and root ligament; the relationship between suture location and maximum failure load has not been investigated in a simulated surgical repair. (A) Using a knottable, 2-mm-wide, ultra-high-molecular-weight polyethylene (UHMWPE) braided tape for transosseous meniscal root repair with a simple suture technique will give rise to a higher maximum failure load than a repair made using No. 2 UHMWPE standard suture material for simple suture repair. (B) Suture position is an important factor in determining the maximum failure load. Controlled laboratory study. In part A, the posterior root attachment of the medial meniscus was divided in 19 porcine knees. The tibias were potted, and repair of the medial meniscus posterior root was performed. A suture-passing device was used to place 2 simple sutures into the posterior root of the medial meniscus during a repair procedure that closely replicated single-tunnel, transosseous surgical repair commonly used in clinical practice. Ten tibias were randomized to repair with No. 2 suture (Suture group) and 9 tibias to repair with 2-mm-wide knottable braided tape (Tape group). The repair strength was assessed by maximum failure load measured by use of a materials testing machine. Micro-computed tomography (CT) scans were obtained to assess suture positions within the meniscus. The wide range of maximum failure load appeared related to suture position. In part B, 10 additional porcine knees were prepared. Five knees were randomized to the Suture group and 5 to the Tape group. All repairs were standardized for location, and the repair was placed in the body of the meniscus. A custom image registration routine was created to coregister all 29 menisci, which allowed the distribution of maximum failure load versus repair location to be visualized with a heat map. In part A, higher maximum failure load was found for the Tape group (mean, 86.7 N; 95% CI, 63.9-109.6 N) compared with the Suture group (mean, 57.2 N; 95% CI, 30.5-83.9 N). The 3D micro-CT analysis of suture position showed that the mean maximum failure load for repairs placed in the meniscus body (mean, 104 N; 95% CI, 81.2-128.0 N) was higher than for those placed in the root ligament (mean, 35.1 N; 95% CI, 15.7-54.5 N). In part B, the mean maximum failure load was significantly greater for the Tape group, 298.5 N ( P = .016, Mann-Whitney U; 95% CI, 183.9-413.1 N), compared with that for the Suture group, 146.8 N (95% CI, 82.4-211.6 N). Visualization with the heat map revealed that small variations in repair location on the meniscus were associated with large differences in maximum failure load; moving the repair entry point by 3 mm could reduce the failure load by 50%. The use of 2-mm braided tape provided higher maximum failure load than the use of a No. 2 suture. The position of the repair in the meniscus was also a highly significant factor in the properties of the constructs. The results provide insight into material and location for optimal repair strength.
Zhao, Jie; Liu, Zhixiong; Liu, Yunsheng; Liu, Jinfang; Fang, Wenhua; Rao, Yihua; Yang, Liang; Yuan, Xianrui
2010-03-01
To evaluate the efficacy of dural tenting suture and epidural drainage in craniotomy. In 145 cases of intracranial lesions, dural tenting suture and epidural drainage were performed to prevent epidural hematoma. Postoperative computed tomography (CT) showed no epidural hematoma required surgery in both groups. Both dural tenting suture and epidural drainage are effective in preventing epidural hematoma. Hemostasis is the key step. Dural tenting suture without epidural drainage relieves psychological stress. It decreases the risk of intracranial infection and avoids some unusual complications.
Krishnan, R; Izadi, S; Morton, C E; Marsh, I B
2007-07-01
Frost sutures are temporary suspension sutures conventionally used in oculoplastics. The case is presented here of a patient with multiple orbital fractures who developed worsening conjunctival chemosis and pseudoproptosis. This patient was managed successfully with Frost sutures. To the best of the authors' knowledge, there is no documented use of Frost sutures in this type of case. It is emphasized that this technique should only be considered following rigorous exclusion of retrobulbar pathology and careful attention towards early detection of raised intraocular pressure.
Fujii, Masataka; Furumatsu, Takayuki; Kodama, Yuya; Miyazawa, Shinichi; Hino, Tomohito; Kamatsuki, Yusuke; Yamada, Kazuki; Ozaki, Toshifumi
2017-05-01
Medial meniscus posterior root has an important role in the maintenance of knee articular cartilage. Although pullout repair of the medial meniscus posterior root tear has become a gold standard, it has several difficulties for suturing. We have developed a modified Mason-Allen suture technique using the FasT-Fix all-inside suture device combined with Ultrabraid. The present suture technique allows a strong grasping of the medial meniscus posterior horn for arthroscopic pullout repair.
Mesa, M.G.; Magie, R.J.; Copeland, E.S.; Christiansen, H.E.
2011-01-01
Radio-tagged adult Pacific lamprey Entosphenus tridentatus held in a raceway with Plexiglas-lined walls and bottom healed more slowly and retained sutures longer than fish held in an all-concrete raceway or one with Plexiglas walls and a cobble-lined bottom. On all substrata, healing depended on when sutures were lost, and fish that lost their sutures in <14 days post-surgery healed faster than those that kept sutures longer. Long-term suture retention led to tissue trauma, infection and poor survival.
Post thyroidectomy suture granuloma: a cytological diagnosis.
Javalgi, Anita P; Arakeri, Surekha U
2013-04-01
There are known post thyroidectomized complications, a suture granuloma being less frequent, with its late complication mimicking recurrent thyroid cancer. A suture granuloma is a benign, granulomatous inflammatory reaction that occurs due to the use of non absorbable suture. It constitutes one of the late complications which altogether make up less than 2% of its incidence. A suture granuloma is similar to a foreign body reaction and it usually develops slowly as a painless, palpable asymptomatic mass over the years. It mimics a cancer recurrence or a lymph node metastasis. Here, we are reporting a case of a post thyroidectomy suture granuloma in a 46 years old lady who presented with a painless swelling in the lateral neck, with a past history of thyroidectomy 5 years back.
Neurotensin decreases pepsin output and gastrointestinal motility in chickens.
Degolier, T F; Duke, G E; Carraway, R E
1997-10-01
Two experiments were conducted to determine the effect of neurotensin on gastric secretion and gastrointestinal motility in conscious chickens. Chickens were surgically fitted with a cannula to collect secretions from the proventriculus and strain gauge transducers sutured to the gizzard, duodenum, and ileum in order to detect contractions. Peripheral intravenous infusion of physiological levels of neurotensin inhibited pepsin output from the proventriculus, but had no effect on the volume or pH of gastric secretions. Neurotensin also inhibited both the frequency and strength of gastrointestinal contractions when compared to motility patterns following infusion of isotonic 0.9% (wt/vol) saline. The frequency of occurrence of small intestinal refluxes was not affected by neurotensin. These results coupled with our earlier work, which demonstrated that neurotensin is released by the presence of oleic acid in the duodenum, indicate that neurotensin may function as an enterogastrone released by lipids in the gastrointestinal tract of the chicken. This overall inhibitory effect of neurotensin on the avian gut indicates that it is involved in the postprandial regulation of digestion, especially lipid digestion.
Kiriyama, Yoshimori; Matsumoto, Hideo; Toyama, Yoshiaki; Nagura, Takeo
2014-02-01
The aim of this study was to develop a new suture tension sensor for musculoskeletal soft tissue that shows deformation or movements. The suture tension sensor was 10 mm in size, which was small enough to avoid conflicting with the adjacent sensor. Furthermore, the sensor had good linearity up to a tension of 50 N, which is equivalent to the breaking strength of a size 1 absorbable suture defined by the United States Pharmacopeia. The design and mechanism were analyzed using a finite element model prior to developing the actual sensor. Based on the analysis, adequate material was selected, and the output linearity was confirmed and compared with the simulated result. To evaluate practical application, the incision of the skin and capsule were sutured during simulated total knee arthroplasty. When conventional surgery and minimally invasive surgery were performed, suture tensions were compared. In minimally invasive surgery, the distal portion of the knee was dissected, and the proximal portion of the knee was dissected additionally in conventional surgery. In the skin suturing, the maximum tension was 4.4 N, and this tension was independent of the sensor location. In contrast, the sensor suturing the capsule in the distal portion had a tension of 4.4 N in minimally invasive surgery, while the proximal sensor had a tension of 44 N in conventional surgery. The suture tensions increased nonlinearly and were dependent on the knee flexion angle. Furthermore, the tension changes showed hysteresis. This miniature tension sensor may help establish the optimal suturing method with adequate tension to ensure wound healing and early recovery.
Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent
2014-01-01
Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965
Walsh, M.G.; Bjorgo, K.A.; Isely, J.J.
2000-01-01
To determine the effects of surgical implantation method and temperature on mortality and transmitter loss, we compared two antenna placements (trailing antenna versus shielded needle) and two suture materials (absorbable versus nonabsorbable) in hybrid striped bass Morone saxitilis x Morone chrysops (227-410 mm total length) that had been surgically implanted with simulated transmitters and held at high (22-29??C) and low (12-18??C) temperatures for 120 d. Fish were individually examined after 7, 30, 60. 90. and 120 d to evaluate suture and wound condition as well as transmitter loss. Neither suture material nor antenna placement affected transmitter loss, mortality, or growth at either high or low temperatures. Absorbable sutures were lost more quickly than were nonabsorbable sutures, but they persisted beyond incision closure at both high and low temperatures. At high temperatures, 50% suture loss occurred by 30 d for absorbable sutures and by 60 d for nonabsorbable sutures. Mortality occurred only at high temperatures but was delayed and was likely caused by peritoneal infection. Transmitter loss was not significant; it occurred only in the low-temperature trial and was caused by pressure necrosis at the incision rather than by suture failure. Temperature significantly affected all responses examined in this study. Significant irritation, infection, and mortality occurred in all treatment groups at high temperatures.
Park, In-Seop; Kim, Sung-Jae
2006-08-01
We introduce a suture technique to repair a peripheral tear near the posterior tibial attachment of the posterior horn. A suture hook was inserted through the posteromedial portal, and the peripheral capsular rim was penetrated from superior to inferior by the sharp hook. Both relay limbs were brought out through the posteromedial portal. The outer limb of the superior peripheral capsular rim was identified with a hemostat. An 18-gauge spinal needle loaded with a No. 0 polydioxanone suture (PDS) was introduced into the joint from the anteromedial portal; it was passed through the joint space until it penetrated the inner torn meniscus. The PDS suture loaded within the needle was pushed into the joint and picked up through the posteromedial portal. The needle was pulled out of the torn meniscus and readvanced over it while the suture was kept loaded. The other limb of the suture from the tip of the spinal needle was retrieved through the posteromedial portal. The initial PDS suture limb was hooked to the shuttle-relay system; it then was passed through the inner torn meniscus and the peripheral capsular rim. The suture limb exiting from the peripheral capsular rim was used as a post and was joined to the other suture limb to form a sliding knot.
Loop ileostomy closure: comparison of cost effectiveness between suture and stapler.
Horisberger, Karoline; Beldi, Guido; Candinas, Daniel
2010-12-01
Closure of loop ileostomy can be safely performed using sutures or staplers. The aim of the present study was to compare the cost effectiveness of three different techniques. A total of 128 consecutive patients who underwent closure of loop ileostomy between January 2002 and December 2008 were analyzed retrospectively. The primary outcome parameter was operative cost. Closure of ileostomy was performed in 66 patients with hand-sewn anastomosis, in 25 patients with stapler only, and in 37 patients with a combination of stapler and suture. There were no differences in terms of early and late postoperative complications. Operative time was significantly longer for "suture only" (101.4 ± 26 min) than for "stapler/suture" (-4.9 min) and "stapler only" (-17.8 min); the difference between the three groups is significant (p = 0.05). Duration of hospital stay was not different among the three groups. Operative costs with "stapler/suture" (1,755.9 ± 355.6 EUR) were significantly higher than with "suture only" (-254 EUR; p = 0.001) and "stapler only" (-236 EUR; p = 0.005). Operative time using the stapler only is significantly shorter than with hand-sewn anastomosis or combinations of stapler and suture. Operative costs are significantly higher for a procedure that includes suture and stapler.
Securing stent during multi-stage laryngotracheoplasty--an evolved technique.
Siegel, Bianca; Bent, John P
2015-09-01
Multi-stage laryngotracheoplasty (LTP) typically requires a stent be secured to the airway for 2-6 weeks. Our technique has evolved over time to securing the stent to the strap muscles and tying a series of knots long enough to leave the suture tail protruding through the skin incision, which simplifies stent removal. Retrospective chart review. Twenty-four patients underwent multi-stage LTP at our institution from 2007 to 2013. Eight patients were excluded from the study because they either did not have a stent placed (n=4), or they had a t-tube placed which was not sutured in place (n=4). Of the remaining 16 patients, 62.5% (n=10) had their stent secured via sutures which were buried below the skin, and 37.5% (n=6) via a long suture tail which was left protruding through the end of the skin incision. An incision was required for stent removal 100% of buried sutures patients, and 33% of exposed suture patients (p=0.0009). Average operative time for stent removal was 60min in the buried sutures group, and 25min in the exposed sutures group (p=0.0075). Securing stents via an exposed suture technique decreases the need for making a skin incision during the second stage of the operation, and significantly decreases the operative time of the second stage. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Nickel-Titanium Wire as Suture Material: A New Technique for the Fixation of Skin.
Li, Haidong; Song, Tao
2018-01-29
To introduce nickel-titanium wire as suture material for closure of incisions in cleft lip procedures. Closure of skin incisions using nickel-titanium wire as suture material, with postoperative follow-up wound evaluation. There was excellent patient satisfaction and good cosmetic outcome. Nickel-titanium wire is an excellent alternative for suture closure of cleft lip surgical incisions.
A comparison of lateral ankle ligament suture anchor strength.
Barber, F Alan; Herbert, Morley A; Crates, John M
2013-06-01
Lateral ankle ligament repairs increasingly use suture anchors instead of bone tunnels. Our purpose was to compare the biomechanical properties of a knotted and knotless suture anchor appropriate for a lateral ankle ligament reconstruction. In porcine distal fibulae, 10 samples of 2 different PEEK anchors were inserted. The attached sutures were cyclically loaded between 10N and 60N for 200 cycles. A destructive pull was performed and failure loads, cyclic displacement, stiffness, and failure mode recorded. PushLock 2.5 anchors failed before 200 cycles. PushLock 100 cycle displacement was less than Morphix 2.5 displacement (p<0.001). Ultimate failure load for anchors completing 200 cycles was 86.5N (PushLock) and 252.1N (Morphix) (p<0.05). The failure mode was suture breaking for all PushLocks while the Morphix failed equally by anchor breaking and suture breakage. The knotted Morphix demonstrated more displacement and greater failure strength than the knotless PushLock. The PushLock failed consistently with suture breaking. The Morphix anchor failed both by anchor breaking and by suture breaking. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Wang, Wei-Wei; Dong, Bao-Cheng
2017-11-01
This systematic review applied meta-analytic procedures to evaluate the curative effect of trans-septal suturing versus nasal packing after septoplasty. Computerized search of the published literature in PubMed, EMBASE, CENTRAL, Cochrane Database of Systematic Reviews, WANFANG, CNKI databases. Randomized trials investigating trans-septal suturing versus nasal packing following septoplasty in patients with deviated nasal septum. Adhesion, septal hematoma, bleeding, septal perforation, infection, pain, headache, or residual septal deviation per randomized patients. 19 randomized controlled trials of 1845 subjects were included. Meta-analysis showed that postoperative pain, headache, and adhesion were significantly lower in trans-septal suturing group. Nasal packing and trans-septal suturing technique appear to be equivalent with regard to postoperative bleeding, hematoma, septal perforation, infection, and residual septal deviation. Trans-septal suturing technology is not only associated with less patient pain, headache, and lower occurrence rate of adhesion after septoplasty but it also relates to higher patient satisfaction and an improved quality of life. The suturing technology can be used as a substitute for traditional nasal packing of the first-line treatment. More well-designed studies are needed to confirm the effect of trans-septal suturing following septoplasty.
Arroyo-Hernández, M; Mellado-Romero, M A; Páramo-Díaz, P; Martín-López, C M; Cano-Egea, J M; Vilá Y Rico, J
2015-01-01
The purpose of this study is to analyze if there is any difference between the arthroscopic reparation of full-thickness supraspinatus tears with simple row technique versus suture bridge technique. We accomplished a retrospective study of 123 patients with full-thickness supraspinatus tears between January 2009 and January 2013 in our hospital. There were 60 simple row reparations, and 63 suture bridge ones. The mean age in the simple row group was 62.9, and in the suture bridge group was 63.3 years old. There were more women than men in both groups (67%). All patients were studied using the Constant test. The mean Constant test in the suture bridge group was 76.7, and in the simple row group was 72.4. We have also accomplished a statistical analysis of each Constant item. Strength was higher in the suture bridge group, with a significant statistical difference (p 0.04). The range of movement was also greater in the suture bridge group, but was not statistically significant. Suture bridge technique has better clinical results than single row reparations, but the difference is not statistically significant (p = 0.298).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noda, Kazuo, E-mail: knoda@kuhp.kyoto-u.ac.jp; Nakamura, Tomoyuki; Komatsu, Yoshihiro
Craniofacial sutures govern the shape of the craniofacial skeleton during postnatal development. The differentiation of suture mesenchymal cells to osteoblasts is precisely regulated in part by signaling through cell surface receptors that interact with extracellular proteins. Here we report that fibulin-5, a key extracellular matrix protein, is important for craniofacial skeletal development in mice. Fibulin-5 is deposited as a fibrous matrix in cranial neural crest-derived mesenchymal tissues, including craniofacial sutures. Fibulin-5-null mice show decreased premaxillary bone outgrowth during postnatal stages. While premaxillo-maxillary suture mesenchymal cells in fibulin-5-null mice were capable of differentiating into osteoblasts, suture cells in mutant mice weremore » less proliferative. Our study provides the first evidence that fibulin-5 is indispensable for the regulation of facial suture mesenchymal cell proliferation required for craniofacial skeletal morphogenesis. - Highlights: • Fibulin-5 is deposited in cranial neural crest-derived mesenchymal tissues. • Fibulin-5-null mice show decreased premaxillary bone growth during postnatal stage. • Fibulin-5 is indispensable for facial suture mesenchymal cell proliferation.« less
[Mechanical suture in classic and laparoscopic general surgery].
Alecu, L; Pascu, A; Deacu, A; Corodeanu, G; Marin, A; Costan, I
2000-01-01
Of this working is the study of employment the mechanical suture in general surgery classic and laparoscopic. We analysed the possibility of accomplishment and postoperatory evolution of 104 mechanical sutures performed in 24 patients, with diverse surgery pathology, operated in Department of General Surgery, between January 1999 and January 2000. Mechanical sutures allowed us to minimize the duration of surgical interventions and to perform some difficult anastomotic assembles (sometimes including creation of organ substitute). We had only two postoperatory fistulas and two postoperatory haemorrhages from anastomotic area (both cases because of bad closing of clips, through tissue excess between anvil and cartridge of the stapler). There are certain advantages in using mechanical sutures (versus manual sutures) consisting in decreasing of time period, both in operation itself and in hospitalization, despite their high level cost.
Post Thyroidectomy Suture Granuloma: A Cytological Diagnosis
Javalgi, Anita P.; Arakeri, Surekha U.
2013-01-01
There are known post thyroidectomized complications, a suture granuloma being less frequent, with its late complication mimicking recurrent thyroid cancer. A suture granuloma is a benign, granulomatous inflammatory reaction that occurs due to the use of non absorbable suture. It constitutes one of the late complications which altogether make up less than 2% of its incidence. A suture granuloma is similar to a foreign body reaction and it usually develops slowly as a painless, palpable asymptomatic mass over the years. It mimics a cancer recurrence or a lymph node metastasis. Here, we are reporting a case of a post thyroidectomy suture granuloma in a 46 years old lady who presented with a painless swelling in the lateral neck, with a past history of thyroidectomy 5 years back. PMID:23730655
Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei
2017-01-01
In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.
Gögler, E
1985-01-01
In different tables the most important faults with enteral sutures and anastomoses in general and at special operations are demonstrated: end-to-end anastomoses with congruent diameter, anastomoses with different diameters, B I, B II, low anterior resection, esophago-jejunostomy. Only if the surgeon has experience in standard technique, faults and risks with mechanical staplers and manual sutures, the advantage-progress of staplers will be effective avoiding special risks. Surgeons without experience may produce real catastrophes which may turn out hopeless without training in manual suture technique.
Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).
Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao
2008-07-01
The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.
Roth, Beat; Birkhäuser, Frédéric D; Thalmann, George N; Zehnder, Pascal
2013-11-01
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The EndoSew(®) prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew(®) suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew(®). The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. To evaluate the feasibility and safety of the novel prototype sewing device EndoSew(®) in placing an extracorporeal resorbable running suture for ileal conduits. We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew(®) running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew(®) only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. A complete EndoSew(®) running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew(®) suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3-10) min and the median (range) suture length was 4.5 (2-5.5) cm. There were no suture-related complications. The EndoSew(®) procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew(®) has the potential to facilitate the intracorporeal construction of urinary diversions. © 2013 BJU International.
Lorbach, Olaf; Bachelier, Felix; Vees, Jochen; Kohn, Dieter; Pape, Dietrich
2008-08-01
Double-row repair is suggested to have superior biomechanical properties in rotator cuff reconstruction compared with single-row repair. However, double-row rotator cuff repair is frequently compared with simple suture repair and not with modified suture configurations. Single-row rotator cuff repairs with modified suture configurations have similar failure loads and gap formations as double-row reconstructions. Controlled laboratory study. We created 1 x 2-cm defects in 48 porcine infraspinatus tendons. Reconstructions were then performed with 4 single-row repairs and 2 double-row repairs. The single-row repairs included transosseous simple sutures; double-loaded corkscrew anchors in either a double mattress or modified Mason-Allen suture repair; and the Magnum Knotless Fixation Implant with an inclined mattress. Double-row repairs were either with Bio-Corkscrew FT using modified Mason-Allen stitches or a combination of Bio-Corkscrew FT and PushLock anchors using the SutureBridge Technique. During cyclic load (10 N to 60-200 N), gap formation was measured, and finally, ultimate load to failure and type of failure were recorded. Double-row double-corkscrew anchor fixation had the highest ultimate tensile strength (398 +/- 98 N) compared to simple sutures (105 +/- 21 N; P < .0001), single-row corkscrews using a modified Mason-Allen stitch (256 +/- 73 N; P = .003) or double mattress repair (290 +/- 56 N; P = .043), the Magnum Implant (163 +/- 13 N; P < .0001), and double-row repair with PushLock and Bio-Corkscrew FT anchors (163 +/- 59 N; P < .0001). Single-row double mattress repair was superior to transosseous sutures (P < .0001), the Magnum Implant (P = .009), and double-row repair with PushLock and Bio-Corkscrew FT anchors (P = .009). Lowest gap formation was found for double-row double-corkscrew repair (3.1 +/- 0.1 mm) compared to simple sutures (8.7 +/- 0.2 mm; P < .0001), the Magnum Implant (6.2 +/- 2.2 mm; P = .002), double-row repair with PushLock and Bio-Corkscrew FT anchors (5.9 +/- 0.9 mm; P = .008), and corkscrews with modified Mason-Allen sutures (6.4 +/- 1.3 mm; P = .001). Double-row double-corkscrew anchor rotator cuff repair offered the highest failure load and smallest gap formation and provided the most secure fixation of all tested configurations. Double-loaded suture anchors using modified suture configurations achieved superior results in failure load and gap formation compared to simple suture repair and showed similar loads and gap formation with double-row repair using PushLock and Bio-Corkscrew FT anchors. Single-row repair with modified suture configurations may lead to results comparable to several double-row fixations. If double-row repair is used, modified stitches might further minimize gap formation and increase failure load.
Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Mays, Matthew M; Rapley, Jay H
2010-03-01
To evaluate the strength and suture-tendon interface security of various suture anchors triply and doubly loaded with ultrahigh-molecular weight polyethylene-containing sutures and to evaluate the relative effectiveness of placing these anchors in a single-row or double-row arrangement by cyclic loading and then destructive testing. The infraspinatus muscle was reattached to the original humeral footprint by use of 1 of 5 different repair patterns in 40 bovine shoulders. Two single-row repairs and three double-row repairs were tested. High-strength sutures were used for all repairs. Five groups were studied: group 1, 2 triple-loaded screw suture anchors in a single row with simple stitches; group 2, 2 triple-loaded screw anchors in a single row with simple stitches over a fourth suture passed perpendicularly ("rip-stop" stitch); group 3, 2 medial and 2 lateral screw anchors with a single vertical mattress stitch passed from the medial anchors and 2 simple stitches passed from the lateral anchors; group 4, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors capturing the medial sutures in a "crisscross" spanning stitch; and group 5, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors creating a "suture-bridge" stitch. The specimens were cycled between 10 and 180 N at 1.0 Hz for 3,500 cycles or until failure. Endpoints were cyclic loading displacement (5 and 10 mm), total displacement, and ultimate failure load. A single row of triply loaded anchors was more resistant to stretching to a 5- and 10-mm gap than the double-row repairs with or without the addition of a rip-stop suture (P < .05). The addition of a rip-stop stitch made the repair more resistant to gap formation than a double row repair (P < .05). The crisscross double row created by 2 medial double-loaded suture anchors and 2 lateral push-in anchors stretched more than any other group (P < .05). Double-row repairs with either crossing sutures or 4 separate anchor points were more likely to fail (5- or 10-mm gap) than a single-row repair loaded with 3 simple sutures. The triple-loaded anchors with ultrahigh-molecular weight polyethylene-containing sutures placed in a single row were more resistant to stretching than the double-row groups. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Cox, Joseph T; Shorten, Peter L; Gould, Gregory C; Markert, Ronald J; Barnett, Michael D; Laughlin, Richard T
2014-11-01
Surgical treatment of insertional Achilles tendinopathy often involves detachment and debridement of the Achilles tendon insertion. A recent study has shown that knotted suture bridge fixation of the Achilles to the calcaneus is biomechanically superior to single-row fixation, but there is an absence of literature on the use of different suture bridge constructs to repair the Achilles tendon. There will be no significant difference in the load to failure, mode of failure, tendon strain, tendon stiffness, repair site gapping, or footprint size when comparing knotted suture bridge repair to knotless suture bridge repair of the Achilles tendon after detachment for insertional Achilles tendinopathy. Controlled laboratory study. A single specimen from each pair of 10 cadaveric Achilles tendons was randomized to 1 of 2 Achilles insertion repair groups: knotted (n = 10) or knotless (n = 10) suture bridge repair. Repaired footprint size was measured, and then cyclic testing from 10 to 100 N for 2000 cycles was performed. This was followed by measurement of tendon strain, repair site displacement, load to failure, and tendon stiffness. The knotted suture bridge repair had a significantly higher load to failure compared with the knotless suture bridge (mean ± SD, 317.8 ± 93.6 N vs 196.1 ± 12.1 N, respectively; P = .001). All constructs failed at the tendon-suture interface. Tendon strain after cyclic testing was significantly greater in the knotless (1.20 ± 1.05) compared with the knotted (0.39 ± 0.4) suture repair groups (P = .011). There was no significant difference in footprint size between the knotted (230.3 ± 63.3 mm(2)) and knotless (248.5 ± 48.8 mm(2)) groups (P = .40). There was also no significant difference in stiffness (knotted = 76.4 ± 8.0 N/mm; knotless = 69.6 ± 10.9 N/mm; P = .17) and repair site displacement after cyclic testing (knotted = 2.8 ± 1.2 mm; knotless = 3.6 ± 1.1 mm; P = .17). During suture bridge repair of the Achilles tendon after detachment, knots at the proximal suture anchors significantly improve the biomechanical strength of the repair. This study demonstrated that the knotless suture bridge repair had a significantly lower load to failure than the knotted suture bridge. Surgeons should be aware of these biomechanical differences, as they influence the postoperative rehabilitation protocol and may lead to higher surgical complication rates. © 2014 The Author(s).
Cerminara, Anthony J; LaPrade, Christopher M; Smith, Sean D; Ellman, Michael B; Wijdicks, Coen A; LaPrade, Robert F
2014-12-01
A common treatment for posterior meniscal root tears is transtibial pull-out repair, which has been biomechanically reported to restore tibiofemoral contact mechanics to those of the intact knee. Biomechanical data suggest that there is significant displacement of the repaired meniscal root with cyclic loading, which may be responsible for the poor healing and meniscal extrusion demonstrated in some clinical studies. The purpose of this study was to quantify the time-zero displacement of the posterior meniscal root in response to cyclic loading after transtibial pull-out repair and to quantify the individual contributions to displacement of the following: (1) suture elongation, (2) button-bone interface, and (3) meniscus-suture interface. The meniscus-suture interface was hypothesized to result in significantly more displacement than the button-bone interface or suture elongation. Descriptive laboratory study. Transtibial pull-out repair of the posterior medial meniscal root was performed in 6 porcine knees, and cyclic displacement was measured using a loading protocol representative of postoperative rehabilitation. Displacement from (1) suture elongation, (2) the button-bone interface, and (3) the meniscus-suture interface was determined by cyclically loading 6 specimens for each construct using the same loading protocol to determine the contribution of each component to the overall displacement of the repair construct. After 1000 cycles, the repair construct displaced by a mean of 3.28 mm (95% CI, 2.07-4.49). The meniscus-suture component (mean, 2.52 mm; 95% CI, 2.21-2.83) displaced significantly more than the button-bone component (mean, 0.90 mm; 95% CI, 0.64-1.15; P = .006) and suture elongation component (mean, 0.71 mm; 95% CI, 0.36-1.06; P = .006) after 1000 cycles. Displacement of the button-bone and suture elongation components was not significantly different after 1000 cycles (P = .720). There was substantial displacement of the posterior medial meniscal root repaired with the transtibial pull-out technique under a cyclic loading protocol simulating postoperative rehabilitation. The meniscus-suture interface contributed to significantly more displacement than the button-bone interface and suture elongation in the transtibial pull-out repair construct. The results provide a framework for optimizing the transtibial pull-out repair technique. Future studies should focus on improving suture fixation strength within the meniscus-suture interface. © 2014 The Author(s).
Automation of a suturing device for minimally invasive surgery.
Göpel, Tobias; Härtl, Felix; Schneider, Armin; Buss, Martin; Feussner, Hubertus
2011-07-01
In minimally invasive surgery, hand suturing is categorized as a challenge in technique as well as in its duration. This calls for an easily manageable tool, permitting an all-purpose, cost-efficient, and secure viscerosynthesis. Such a tool for this field already exists: the Autosuture EndoStitch(®). In a series of studies the potential for the EndoStitch to accelerate suturing has been proven. However, its ergonomics still limits its applicability. The goal of this study was twofold: propose an optimized and partially automated EndoStitch and compare the conventional EndoStitch to the optimized and partially automated EndoStitch with respect to the speed and precision of suturing. Based on the EndoStitch, a partially automated suturing tool has been developed. With the aid of a DC motor, triggered by a button, one can suture by one-fingered handling. Using the partially automated suturing manipulator, 20 surgeons with different levels of laparoscopic experience successfully completed a continuous suture with 10 stitches using the conventional and the partially automated suture manipulator. Before that, each participant was given 1 min of instruction and 1 min for training. Absolute suturing time and stitch accuracy were measured. The quality of the automated EndoStitch with respect to manipulation was tested with the aid of a standardized questionnaire. To compare the two instruments, t tests were used for suturing accuracy and time. Of the 20 surgeons with laparoscopic experience (fewer than 5 laparoscopic interventions, n=9; fewer than 20 laparoscopic interventions, n=7; more than 20 laparoscopic interventions, n=4), there was no significant difference between the two tested systems with respect to stitching accuracy. However, the suturing time was significantly shorter with the Autostitch (P=0.01). The difference in accuracy and speed was not statistically significant considering the laparoscopic experience of the surgeons. The weight and size of the Autostitch have been criticized as well as its cable. However, the comfortable handhold, automatic needle change, and ergonomic manipulation have been rated positive. Partially automated suturing in minimally invasive surgery offers advantages with respect to the speed of operation and ergonomics. Ongoing work in this field has to concentrate on minimization, implementation in robotic systems, and development of new operation methods (NOTES).
Custis, Trenton; Armstrong, April W; King, Thomas H; Sharon, Victoria R; Eisen, Daniel B
2015-08-01
Although applying adhesive strips to a wound closure has been shown to have outcomes equivalent to those with cuticular suturing, it is unknown whether adhesive strips provide additional benefit compared with dermal suturing alone. To determine whether the addition of adhesive strips to a wound closed with buried interrupted subcuticular sutures improves outcomes following wound closure. A prospective, randomized split-wound intervention was conducted between November 14, 2013, and May 16, 2014, in patients who underwent cutaneous surgical procedures at the University of California, Davis, outpatient dermatology clinic. Fifty-seven patients 18 years or older with postoperative defects of at least 3 cm, resulting from either Mohs micrographic surgical procedures or surgical excision, were screened for participation. Nine patients were excluded and 48 were enrolled. Half of each wound was randomized to receive buried interrupted subcuticular sutures and overlying adhesive strips and the other half received buried interrupted subcuticular sutures only. At 3 months' follow-up, each patient and 2 blinded observers evaluated the wound using the Patient Observer Scar Assessment Scale. The total mean (SD) Patient Observer Scar Assessment Scale score for observers for the side that received a combination of adhesive strips and buried interrupted subcuticular suturing (12.3 [4.8]) and the side that received sutures only (12.9 [6.3]) did not differ significantly at 3 months (P = .32). There was no significant difference in the total patient assessment scale score between the combination closure (14.0 [7.6]) and sutures only (14.7 [7.6]) sides at 3 months (P = .39). There was also no significant difference between the 2 closure methods in terms of mean (SD) scar width (both methods: 1.1 [0.8] mm, P = .89) at follow-up. Combination closure with adhesive strips and buried interrupted subcuticular suturing was not significantly associated with improved overall scar assessment compared with buried interrupted subcuticular suturing alone when evaluated by blinded observers or the patients themselves. Our results do not support the use of adhesive strips as a means to improve cosmetic outcomes or reduce scar width. clinicaltrials.gov Identifier: NCT01979497.
Assessment of the Resistance of Several Suture Techniques in Human Cadaver Achilles Tendons.
Manent, Andrea; Lopez, Laia; Vilanova, Joan; Mota, Tiago; Alvarez, Jordi; Santamaría, Alejandro; Oliva, Xavier Martí
Many treatments are available for acute Achilles tendon ruptures, conservative and surgical, with none superior to another. For surgical treatment, one can use various techniques. Recent studies have shown that double stitches are superior to simple sutures. Therefore, in the present study, we sought to determine the suture technique that is the most resistant to rupture. We performed an experimental anatomic study with 27 fresh-frozen human cadaveric Achilles tendons obtained through the body donation program of the University of Barcelona, testing the maximum strength. We simulated a rupture by performing resection in the middle portion of the tendon, 4 cm proximal to the calcaneus insertion. We then evaluated the double Kessler, double Bunnell, Krackow, and percutaneous Ma and Griffith technique. We used absorbable suture (polydioxanone no. 1) with all the techniques. Traction was performed using a machine that pulls the tendon at 10 to 100 N in 1000 repetitive cycles. Statistical analysis was performed using the χ 2 test and analysis of variance, with the 95% confidence intervals (p < .05). All repairs failed at the site of the suture knots, with none pulling out through the substance of the tendon. We found no significant differences among the different open suture techniques (p > .05). The Krackow suture presented with superior resistance, with a rupture rate 16.70% but with a mean elongation of 7.11 mm. The double Bunnell suture had the same rupture rate as the Krakow suture (16.70%) but with an inferior mean elongation of 4.53 mm. The Krackow and Bunnell suture were superior in endurance, strength of failure, and primary stability compared with the other suture types. However, the former presented with greater tendon elongation, although the difference was not statistically significant. Therefore, according to our findings and the published data, we recommend double Bunnell sutures for the surgical treatment of acute Achilles tendon rupture. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Richard S.; Deters, Katherine A.; Cook, Katrina V.
Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the ability to make shorter incisions that may warrant using only a single suture for closure. However, it is not known if one suture will sufficiently hold the incision closed, particularly when outward pressure is placed on the surgical site such as when migrating fish experience pressure changes associated with passage at hydroelectric dams. The objective of this research was to evaluate the effectiveness of single-suture incision closures on juvenile Chinook salmon (Oncorhynchus tshawytscha). Juvenile Chinook salmon were surgically implanted with a 2012 Juvenile Salmonmore » Acoustic Telemetry System (JSATS) transmitter (0.30 g) and a passive integrated transponder tag (0.10 g) and incisions were closed with either one suture or two sutures. Mortality and tag retention were monitored and fish were examined after 7 and 14 days to evaluate tissue responses. In a separate experiment, surgically implanted fish were exposed to simulated turbine passage and then examined for expulsion of transmitters, expulsion of viscera through the incision, and mortal injury. With incisions closed using a single suture, there was no mortality or tag loss and similar or reduced tissue reaction compared to incisions closed with two sutures. Further, surgery time was significantly reduced when one suture was used, which leads to less handling and reduced stress. No tags were expelled during pressure scenarios and expulsion of viscera only occurred in two non-mortally injured fish (5%) with single sutures that were also exposed to very high pressure changes. No viscera expulsion was present in fish exposed to pressure scenarios likely representative of hydroturbine passage at many Columbia River dams (e.g. <2.7 ratio of pressure change; an acclimation pressure of 146.2 absolute kpa and a lowest exposure pressure of ~ 53.3 absolute kpa). Based on these results, we recommend the use of a single suture for surgical implantation of transmitters with incisions that are approximately 5 1/2 mm long after tag insertion.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deters, Katherine A.; Brown, Richard S.; Boyd, James W.
2012-01-02
The size reduction of acoustic transmitters has led to a reduction in the length of incision needed to implant a transmitter. Smaller suture knot profiles and fewer sutures may be adequate for closing an incision used to surgically implant an acoustic microtransmitter. As a result, faster surgery times and reduced tissue trauma could lead to increased survival and decreased infection for implanted fish. The objective of this study was to assess the effects of five suturing techniques on mortality, tag and suture retention, incision openness, ulceration, and redness in juvenile Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Suturing wasmore » performed by three surgeons, and study fish were held at two water temperatures (12°C and 17°C). Mortality was low and tag retention was high for all treatments on all examination days (7, 14, 21, and 28 days post-surgery). Because there was surgeon variation in suture retention among treatments, further analyses included only the one surgeon who received feedback training in all suturing techniques. Incision openness and tissue redness did not differ among treatments. The only difference observed among treatments was in tissue ulceration. Incisions closed with a horizontal mattress pattern had more ulceration than other treatments among fish held for 28 days at 17°C. Results from this study suggest that one simple interrupted 1 × 1 × 1 × 1 suture is adequate for closing incisions on fish under most circumstances. However, in dynamic environments, two simple interrupted 1 × 1 × 1 × 1 sutures should provide adequate incision closure. Reducing bias in survival and behavior tagging studies is important when making comparisons to the migrating salmon population. Therefore, by minimizing the effects of tagging on juvenile salmon (reduced tissue trauma and reduced surgery time), researchers can more accurately estimate survival and behavior.« less
Diagnostic performance of skeletal maturity for the assessment of midpalatal suture maturation.
Angelieri, Fernanda; Franchi, Lorenzo; Cevidanes, Lucia H S; McNamara, James A
2015-12-01
The aim of this study was to analyze the diagnostic performance of the cervical vertebral maturation (CVM) method in estimating accurately the stages of maturation of the midpalatal suture. Cone-beam computed tomography (CBCT) images from 142 subjects (84 female, 58 male; mean age, 14.8 ± 9.7 years) were analyzed by 2 calibrated examiners to define, by visual analysis, the maturational stages of the cervical vertebrae and the midpalatal suture. These CBCT images were required by orthodontists and surgeons for diagnosis and treatment purposes. Positive likelihood ratios (LHRs) were calculated to evaluate the diagnostic performance of the CVM stages in identifying the maturational stages of the midpalatal suture. Positive LHRs greater than 10 were found for several cervical vertebral stages (CSs), including CS1 and CS2 for the identification of midpalatal suture stages A and B, CS3 for the diagnosis of midpalatal suture stage C, and CS5 for the assessment of midpalatal suture stages D and E. These positive LHRs indicated large and often conclusive increases in the likelihood that the CVM stages were associated with specific stages of midpalatal suture maturation. At CS4, there were a moderate positive LHR for stage C and low positive LHRs for stages D and E. Most CVM stages can be used for the diagnosis of the stages of maturation of the midpalatal suture, so that CBCT imaging may not be necessary in these patients. In the postpubertal period, however, an assessment of the midpalatal suture maturation using CBCT images may be indicated in deciding between conventional rapid maxillary expansion and surgically assisted rapid maxillary expansion. On the other hand, if the CVM stage cannot be assessed, chronologic age may be a viable alternative to predict some midpalatal suture stages (particularly the early stages). Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Comparison of Suture-Based Anchors and Traditional Bioabsorbable Anchors in Foot and Ankle Surgery.
Hembree, W Chad; Tsai, Michael A; Parks, Brent G; Miller, Stuart D
We compared the pullout strength of a suture-based anchor versus a bioabsorbable anchor in the distal fibula and calcaneus and evaluated the relationship between bone mineral density and peak load to failure. Eight paired cadaveric specimens underwent a modified Broström procedure and Achilles tendon reattachment. The fibula and calcaneus in the paired specimens received either a suture-based anchor or a bioabsorbable suture anchor. The fibular and calcaneal specimens were loaded to failure, defined as a substantial decrease in the applied load or pullout from the bone. In the fibula, the peak load to failure was significantly greater with the suture-based versus the bioabsorbable anchors (133.3 ± 41.8 N versus 76.8 ± 35.3 N; p = .002). No significant difference in load with 5 mm of displacement was found between the 2 groups. In the calcaneus, no difference in the peak load to failure was found between the 2 groups, and the peak load to failure with 5 mm of displacement was significantly lower with the suture-based than with the bioabsorbable anchors (52.2 ± 9.8 N versus 75.9 ± 12.4 N; p = .003). Bone mineral density and peak load to failure were significantly correlated in the fibula with the suture-based anchor. An innovative suture-based anchor had a greater peak load to failure compared with a bioabsorbable anchor in the fibula. In the calcaneus, the load at 5 mm of displacement was significantly lower in the suture-based than in the bioabsorbable group. The correlation findings might indicate the need for a cortical bone shelf with the suture-based anchor. Suture-based anchors could be a viable alternative to bioabsorbable anchors for certain foot and ankle procedures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Ivasauskas, Tomas J.; Bettoli, P.W.; Holt, T.
2012-01-01
We examined the effects of suture material (braided silk versus Monocryl) and relative ultrasonic transmitter size on healing, growth, mortality, and tag retention in rainbow trout Oncorhynchus mykiss. In experiment 1, 40 fish (205-281mmtotal length [TL], 106-264 g) were implanted with Sonotronics IBT-96-2 (23??7 mm; weight in air, 4.4 g; weight in water, 2.4 g) or IBT 96-2E (30 ?? 7 mm; weight in air, 4.9 g; weight in water, 2.4 g) ultrasonic telemetry tags. In experiment 2, 20 larger fish (342-405 mm TL; 520-844 g) were implanted with Sonotronics IBT-96-5 ultrasonic tags (36 ?? 11 mm; weight in air, 9.1 g; weight in water, 4.1 g). The tag burdens for all implanted fish ranged from 1.1% to 3.4%, and fish in both studies were held at 10-15??C. At the conclusion of both experiments (65 d after surgery), no mortalities were observed in any of the 60 tagged fish, most incisions were completely healed, and all fish in both experiments grew in length, although tagged fish grew more slowly than control fish in experiment 1. In both experiments, fish sutured with silk expelled tags more frequently than those sutured with Monocryl. Expulsion was observed in 45-50% of the fish sutured with silk and 0-25% of the fish sutured withMonocryl. Tag expulsion was not observed until 25-35 d after surgery. Fish sutured with silk exhibited a more severe inflammatory response 3 weeks after surgery than those sutured with Monocryl. In experiment 1, the rate of expulsion was linked to the severity of inflammation. Although braided silk sutures were applied faster than Moncryl sutures in both experiments, knots tied with either material were equally reliable and fish sutured with Monocryl experienced less inflammation and lower rates of tag expulsion. American Fisheries Society 2012.
Chu, Haikun; Xu, Yanbin; Chu, Haipeng; Xu, Yajun; Zhou, Fengji; Yu, Xin; Li, Hui; Ji, Xiaofeng
2012-06-01
To investigate the effectiveness of modified percutaneous suture in repairing acute closed Achilles tendon rupture by comparing with conventional open suture. Between January 2006 and October 2009, 50 patients with acute closed Achilles tendon rupture were treated with modified percutaneous suture by making 5 small incisions at both sides of Achilles tendon and zigzag suture (improved group, n=22) and with Kessler suture (conventional group, n=28), respectively. No significant difference was found in gender, age, time from injury to operation between 2 groups (P > 0.05). In improved group, the patients achieved healing of incisions by first intention after operation and no complication occurred; however, incision infection occurred in 1 case, Achilles tendon re-rupture in 1 case, and incision scar contracture in 2 cases in conventional group. The operation time of improved group [(38.7 +/- 6.6) minutes] was significantly shorter (t=-12.29, P=0.00) than that of conventional group [(52.3 +/- 6.9) minutes]; the blood loss of improved group [(4.9 +/- 2.0) mL] was significantly less (t=-25.20, P=0.00) than that of conventional group [(40.7 +/- 7.1) mL]. The patients were followed up 2-3 years (mean, 29.9 months). The American Orthopaedic Foot and Ankle Society (AOFAS) score was 99.6 +/- 1.0 in improved group and was 98.4 +/- 3.0 in conventional group, showing no significant difference between 2 groups (t=1.66, P=0.10). Comparison with conventional open suture, modified percutaneous suture has some advantages, such as easy operation, less complications, rapid recovery of limb function, and so on. Modified percutaneous suture is one of the best choices for the treatment of acute closed Achilles tendon rupture.
Kerr, Natalie C
2011-12-01
Overcorrection of hypotropia subsequent to adjustable suture surgery following inferior rectus recession is undesirable, often resulting in persistent diplopia and reoperation. I hypothesized that overcorrection shift after suture adjustment may be unique to thyroid eye disease, and the use of a nonabsorbable suture may reduce the occurrence of overcorrection. A retrospective chart review of adult patients who had undergone eye muscle surgery with an adjustable suture technique was performed. Overcorrection shifts that occurred between the time of suture adjustment and 2 months postoperatively were examined. Descriptive statistics, linear regression, Anderson-Darling tests, generalized Pareto distributions, odds ratios, and Fisher tests were performed for two overcorrection shift thresholds (>2 and >5 prism diopters [PD]). Seventy-seven patients were found: 34 had thyroid eye disease and inferior rectus recession, 30 had no thyroid eye disease and inferior rectus recession, and 13 patients had thyroid eye disease and medial rectus recession. Eighteen cases exceeded the 2 PD threshold, and 12 exceeded the 5 PD threshold. Statistical analyses indicated that overcorrection was associated with thyroid eye disease (P=6.7E-06), inferior rectus surgery (P=6.7E-06), and absorbable sutures (>2 PD: OR=3.7, 95% CI=0.4-35.0, P=0.19; and >5 PD: OR=6.0, 95% CI=1.1-33.5, P=0.041). After unilateral muscle recession for hypotropia, overcorrection shifts are associated with thyroid eye disease, surgery of the inferior rectus, and use of absorbable sutures. Surgeons performing unilateral inferior rectus recession on adjustable suture in the setting of thyroid eye disease should consider using a nonabsorbable suture to reduce the incidence of postoperative overcorrection.
Kerr, Natalie C.
2011-01-01
Purpose Overcorrection of hypotropia subsequent to adjustable suture surgery following inferior rectus recession is undesirable, often resulting in persistent diplopia and reoperation. I hypothesized that overcorrection shift after suture adjustment may be unique to thyroid eye disease, and the use of a nonabsorbable suture may reduce the occurrence of overcorrection. Methods A retrospective chart review of adult patients who had undergone eye muscle surgery with an adjustable suture technique was performed. Overcorrection shifts that occurred between the time of suture adjustment and 2 months postoperatively were examined. Descriptive statistics, linear regression, Anderson-Darling tests, generalized Pareto distributions, odds ratios, and Fisher tests were performed for two overcorrection shift thresholds (>2 and >5 prism diopters [PD]). Results Seventy-seven patients were found: 34 had thyroid eye disease and inferior rectus recession, 30 had no thyroid eye disease and inferior rectus recession, and 13 patients had thyroid eye disease and medial rectus recession. Eighteen cases exceeded the 2 PD threshold, and 12 exceeded the 5 PD threshold. Statistical analyses indicated that overcorrection was associated with thyroid eye disease (P=6.7E-06), inferior rectus surgery (P=6.7E-06), and absorbable sutures (>2 PD: OR=3.7, 95% CI=0.4–35.0, P=0.19; and >5 PD: OR=6.0, 95% CI=1.1–33.5, P=0.041). Conclusions After unilateral muscle recession for hypotropia, overcorrection shifts are associated with thyroid eye disease, surgery of the inferior rectus, and use of absorbable sutures. Surgeons performing unilateral inferior rectus recession on adjustable suture in the setting of thyroid eye disease should consider using a nonabsorbable suture to reduce the incidence of postoperative overcorrection. PMID:22253487
Installation Assessment of Frankford Arsenal.
1977-10-01
sulfate , sulfuric acid , ac ’solution 40 Hot water bath 41 Nickel plate Nickel sulfate and chloride sulfuric acid , acid ...solution 42 Chromium Copper plate Copper sulfate and sulfuric acid , acid solution 11-14 TABLE 11-2 (continued) Tank No. Plating Process Use Contents...46 Water rinse Water 47 Water rinse Water 48 Water rinse Water 49 Acid Chromic acid , acetic acid , nickel sulfate and sulfuric
USDA-ARS?s Scientific Manuscript database
This study examined the effects of feeding frequency (daily versus every other day [EOD]) on nutrient digestibility/availability of channel catfish, Ictalurus punctatus, reared at optimal (30 C) and suboptimal (24 C) temperatures. A 28% protein practical diet was used as the test diet, and chromic o...
Comparison of different ligature materials used for T-tube esophageal exclusion.
Lee, Y C; Luh, S P; Tsai, C C; Hsu, H C; Chu, S H
1992-03-01
Four different ligature materials--plain catgut, chromic catgut, dexon and silk--were used for ligature of the distal arm during T-tube exclusion of the cervical esophagus in 12 dogs. Ligature by plain catgut was maintained for only a short period, but the duration of esophageal occlusion with the other three ligature materials was around 10 days. Ligated esophageal segments were examined grossly and histologically two months after the procedure. The diameter of the esophageal lumen in the ligated segments had become smaller compared with the neighboring normal esophageal lumen. The most prominent histologic changes were atrophy and fibrosis of the muscle coat, vessel congestion and inflammatory cell infiltration in the ligated segments. These tissue reactions were more severe in the chromic catgut and silk ligatures. Among the 11 evaluable dogs, four had symptoms of dysphagia after removal of the T-tube. All four dogs had a sinus discharge and granuloma formation at the T-tube esophagostoma. The diameter of the esophageal lumen was more constricted in dogs with dysphagia. Among the four ligature materials, dexon had the advantages of a long duration of occlusion, less tissue fibrosis and little sequel of esophageal stenosis, making it the most suitable for ligature during esophageal exclusion.
Biomonitoring chromium III or VI soluble pollution by moss chlorophyll fluorescence.
Chen, Yang-Er; Mao, Hao-Tian; Ma, Jie; Wu, Nan; Zhang, Chao-Ming; Su, Yan-Qiu; Zhang, Zhong-Wei; Yuan, Ming; Zhang, Huai-Yu; Zeng, Xian-Yin; Yuan, Shu
2018-03-01
We systematically compared the impacts of four Cr salts (chromic chloride, chromic nitrate, potassium chromate and potassium bichromate) on physiological parameters and chlorophyll fluorescence in indigenous moss Taxiphyllum taxirameum. Among the four Cr salts, K 2 Cr 2 O 7 treatment resulted in the most significant decrease in photosynthetic efficiency and antioxidant enzymes, increase in reactive oxygen species (ROS), and obvious cell death. Different form the higher plants, although hexavalent Cr(VI) salt treatments resulted in higher accumulation levels of Cr and were more toxic than Cr(III) salts, Cr(III) also induced significant changes in moss physiological parameters and chlorophyll fluorescence. Our results showed that Cr(III) and Cr(VI) could be monitored distinguishably according to the non-photochemical quenching (NPQ) fluorescence of sporadic purple and sporadic lavender images respectively. Then, the valence states and concentrations of Cr contaminations could be evaluated according to the image of maximum efficiency of PSII photochemistry (Fv/Fm) and the quantum yield of PSII electron transport (ΦPSII). Therefore, this study provides new ideas of moss's sensibility to Cr(III) and a new method to monitor Chromium contaminations rapidly and non-invasively in water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Colloidal chromic phosphate /sup 32/P synovectomy in antigen-induced arthritis in the rabbit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howson, M.P.; Shepard, N.L.; Mitchell, N.S.
1988-04-01
Radioisotopes have been employed in the therapy of chronic arthritis, in particular, rheumatoid arthritis for many years. A variety of isotopes have been popularized, and in the last ten years a colloidal solution of radioactive chromic phosphate /sup 32/P has been in use apparently with equivalent efficacy to others such as /sup 169/erbium, /sup 90/yttrium, and /sup 165/dysprosium. No controlled studies on this modality have been reported and few animal studies were found. The efficacy of therapeutic doses of /sup 32/P as a medical synovectomy and its effect on rabbit joints with antigen-induced arthritis were observed in 62 arthritic kneemore » joints in 31 adult rabbits treated on one side with 0.1 microCi of /sup 32/P, the opposite serving as control. The animals were observed over a period of 11 months and examined by histologic and biochemical means. The synovium showed no evidence of radiation necrosis in treated joints. Cartilage of treated and control joints showed similar changes consistent with chronic arthritis, persistent synovitis, progressive chondrocyte degeneration, and decreased matrix metachromasia. The radiosynovectomy had neither removed synovium nor protected the cartilage. Its efficacy in humans is therefore questionable.« less
Evaluation of a novel technique for wound closure using a barbed suture.
Murtha, Amy P; Kaplan, Andrew L; Paglia, Michael J; Mills, Benjie B; Feldstein, Michael L; Ruff, Gregory L
2006-05-01
Suture knots present several disadvantages in wound closure, because they are tedious to tie and place ischemic demands on tissue. Bulky knots may be a nidus for infection, and they may extrude through skin weeks after surgery. Needle manipulations during knot-tying predispose the surgeon to glove perforation. A barbed suture was developed that is self-anchoring, requiring no knots or slack management for wound closure. The elimination of knot tying may have advantages over conventional wound closure methods. This prospective, randomized, controlled trial was designed to show that the use of barbed suture in dermal closure of the Pfannenstiel incision during nonemergent cesarean delivery surgery produces scar cosmesis at 5 weeks that is no worse than that observed with conventional closure using 3-0 polydioxanone suture. Cosmesis was assessed by review of postoperative photographs by a blinded, independent plastic surgeon using the modified Hollander cosmesis score. Secondary endpoints included infection, dehiscence, pain, closure time, and other adverse events. The study enrolled 195 patients, of whom 188 were eligible for analysis. Cosmesis scores did not significantly differ between the barbed suture group and the control group. Rates of infection, dehiscence, and other adverse events did not significantly differ between the two groups. Closure time and pain scores were comparable between the groups. The barbed suture represents an innovative option for wound closure. With a cosmesis and safety profile that is similar to that of conventional suture technique, it avoids the drawbacks inherent to suture knots.
Progressive Tightening of Pulley Sutures for Primary Repair of Large Scalp Wounds
McLaughlin, Jillian M.; Ross, Lindy S.; Phillips, Linda G.; Wagner, Richard F.
2017-01-01
Summary: Scalp defects greater than 2 cm in diameter are not usually amenable to primary closure and require local tissue rearrangement, grafting, tissue expansion, or prolonged second intention healing. Scalp flap reconstruction is a significant undertaking that requires elevation of a total flap surface area that is 3–6 times the size of the defect, often involves profuse bleeding, and can be challenging to perform without conscious sedation or general anesthesia. Anticoagulated and medically complex patients pose additional challenges and limit options for treatment. The pulley suture uses the mechanical advantage of the pulley to distribute tension across a wound and is useful in areas of high tension such as scalp wounds. For scalp wounds greater than 2 cm, pulley sutures are placed along the length of the wound. An assistant exerts equal tension on the pulley sutures, and the surgeon sequentially ties the sutures. The sutures are tightened and retied weekly until complete scalp closure is achieved. The pulley sutures can be used for rapid primary closure of scalp wounds up to 2.5–3.0 cm in diameter under local anesthesia. For scalp wounds larger than 3 cm, we have also found that pulley sutures can be progressively tightened yielding additional tissue expansion every week. Scalp wounds greater than 3.0 cm can be easily closed via primary repair and weekly tightening of pulley sutures without the need for flap reconstruction, traditional tissue expander placement, or second intention healing. PMID:29632771
Bridge Suture for Successful McDonald Emergency Cerclage.
Tanaka, Masaaki; Hori, Yoshiaki; Shirafuji, Aya; Kato, Mitsunori; Kato, Jyun; Kobayashi, Hiroto; Tsuchida, Toru; Fukae, Tsukasa
2017-01-01
To create awareness about a surgical technique termed bridge suture, which is performed as a pretreatment before a McDonald cerclage is performed on an emergency to treat severe cervical insufficiency. Procedures for bridge suture were reviewed in detail and outcomes of 16 patients treated with bridge suture followed by McDonald cerclage were evaluated retrospectively. Using the bridge suture, the edges of uterine cervix were temporarily sutured and the external uterine os was closed, while the hourglass-shaped fetal membranes were concomitantly confined within the cervix; subsequently, a McDonald cerclage was performed. Over a 22-year period, 16 patients with a dilated cervix and bulging fetal membranes were treated using the technique of bridge suture followed by an emergency cerclage. The mean gestational age at cerclage was 22.5 weeks; the mean gestational age at delivery was 30.7 weeks; and the mean interval between cerclage and delivery was 8.2 weeks. In 15 out of 16 cases, cerclage was performed without encountering any complications. No maternal complications, including cervical laceration, were observed. The mean body weight of 17 neonates, including that of a twin, was 1,516 g and of them, 15 neonates survived. The important outcome of bridge suture is the replacement of fetal membranes back into the uterine cavity before McDonald's cerclage is performed. Pretreatment with bridge suture may facilitate the performance of a successful emergency cerclage and contribute to good maternal and neonatal outcomes. © 2016 S. Karger AG, Basel.
Tissue reactions to modern suturing material in colorectal surgery.
Molokova, O A; Kecherukov, A I; Aliev, F Sh; Chernov, I A; Bychkov, V G; Kononov, V P
2007-06-01
Morphological changes in the wall of the large intestine were studied after its manual suturing by a double-row interrupted suture with modern suture threads. Light and scanning electron microscopy showed "fuse properties" and "sawing effect" of polyfilament twisted threads (e.g. vicryl). Monofilament threads were free from these drawbacks and therefore were preferable. Metal elastic threads on the basis of titanium-nickelide alloys caused no inflammatory changes in tissues.
Esophageal healing in the pony: comparison of sutured vs nonsutured esophagotomy.
Stick, J A; Krehbiel, J D; Kunze, D J; Wortman, J A
1981-09-01
Esophageal healing was evaluated in 10 ponies after sutured and nonsutured cervical esophagotomy techniques. Mucosal healing occurred significantly (P less than 0.005) faster after sutured esophagotomies (x = 7.5 days after surgery) than after nonsutured esophagotomies (x = 25.6 days after surgery), based on endoscopic and clinical evaluations. Although endoscopy was an accurate assessment of the return of normal passage of a food bolus through the esophagus, 4 of 10 ponies had radiographic evidence of a sinus tract after the mucosa was considered healed, based on endoscopic and clinical examinations. The surgical skin wound also healed significantly sooner after sutured esophagotomies (x = 10 days) than after nonsutured esophagotomies (x = 33.4 days). A traction diverticulum developed in all ponies with nonsutured esophagotomies, but occurred in only 1 pony with sutured esophagotomy. Minor complications were seen more frequently with sutured esophagotomy than with a nonsutured esophagotomy, but were resolved with local therapy. Saliva appeared to inhibit wound healing. All ponies were fed through esophagostomy tubes until the mucosa at the esophagotomy site was considered healed. Except for 1 sutured esophagotomy that dehisced, sutured esophagotomy was superior to nonsutured esophagotomy, because earlier establishment of a mucosal seal resulted in more rapid healing and reduced nursing care.
Sleiman, Z.; Tanos, V.; Van Belle, Y.; Carvalho, J.L.; Campo, R.
2015-01-01
The efficiency of suturing training and testing (SUTT) model by laparoscopy was evaluated, measuring the suturingskill acquisition of trainee gynecologists at the beginning and at the end of a teaching course. During a workshop organized by the European Academy of Gynecological Surgery (EAGS), 25 participants with three different experience levels in laparoscopy (minor, intermediate and major) performed the 4 exercises of the SUTT model (Ex 1: both hands stitching and continuous suturing, Ex 2: right hand stitching and intracorporeal knotting, Ex 3: left hand stitching and intracorporeal knotting, Ex 4: dominant hand stitching, tissue approximation and intracorporeal knotting). The time needed to perform the exercises is recorded for each trainee and group and statistical analysis used to note the differences. Overall, all trainees achieved significant improvement in suturing time (p < 0.005) as measured before and after completion of the training. Similar significantly improved suturing time differences (p < 0.005) were noted among the groups of trainees with different laparoscopic experience. In conclusion a short well-guided training course, using the SUTT model, improves significantly surgeon’s laparoscopic suturing ability, independently of the level of experience in laparoscopic surgery. Key words: Endoscopy, laparoscopic suturing, psychomotor skills, surgery, teaching, training suturing model. PMID:26977264
Mechanical properties of commercially available nylon sutures in the United States.
Callahan, Travis L; Lear, William; Kruzic, Jamie J; Maughan, Cory B
2017-05-01
Surgeons can choose from a wide selection of commercially available suture brands, which come at a range of prices. There is currently limited evidence in the literature to guide this selection process. This investigation examined the breaking force, stress, and elongation of a variety of commercially available nylon sutures compared to their relative prices. Seven 5-0, nonabsorbable, nylon suture brands were tensile tested in straight, knotted and knot-security configurations according to the procedures outlined by the United States Pharmacopeia for the tensile testing of sutures. Covidien, the cheapest brand tested, had the highest failure load of straight and knot-security tests. Dafilon was found to have the highest breaking force and percent elongation of knot-pull tests. J&J Ethicon and Supramid had the highest percent elongation to failure for straight-pull and knot-security tests, respectively. This study was limited to specific in vitro tensile properties of nylon suture. Other factors affecting suture quality and price, such as needle properties, were not investigated. The data presented in the study provide information for guiding the selection and purchase of sutures according to tensile properties. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 815-819, 2017. © 2016 Wiley Periodicals, Inc.
Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng
2014-01-01
We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507
Hahn, Wolfram; Fricke-Zech, Susanne; Fialka-Fricke, Julia; Dullin, Christian; Zapf, Antonia; Gruber, Rudolf; Sennhenn-kirchner, Sabine; Kubein-Meesenburg, Dietmar; Sadat-Khonsari, Reza
2009-09-01
An investigation was conducted to compare the image quality of prototype flat-panel volume computed tomography (fpVCT) and multislice computed tomography (MSCT) of suture structures. Bone samples were taken from the midpalatal suture of 5 young (16 weeks) and 5 old (200 weeks) Sus scrofa domestica and fixed in formalin solution. An fpVCT prototype and an MSCT were used to obtain images of the specimens. The facial reformations were assessed by 4 observers using a 1 (excellent) to 5 (poor) rating scale for the weighted criteria visualization of the suture structure. A linear mixed model was used for statistical analysis. Results with P < .05 were considered to be statistically significant. The visualization of the suture of young specimens was significantly better than that of older animals (P < .001). The visualization of the suture with fpVCT was significantly better than that with MSCT (P < .001). Compared with MSCT, fpVCT produces superior results in the visualization of the midpalatal suture in a Sus scrofa domestica model.
Moon, Hye-Sung
2018-06-01
Using the da Vinci single-site platform, surgeons can perform more minimally invasive surgery. However, surgical challenges exist due to the limitations of single-site instrumental movements. To aid in the performance of successful robotic single-site hysterectomy, a new suturing technique using the current set of limited instruments is introduced in this study. New vaginal cuff suturing techniques have been used in 55 robotic single-site hysterectomies in our institute over the past 2 years. A needle driver approach utilizing screwing and advancing the needle driver in the correct direction at an increasing angle from the transverse cuff margin with dragging and formation of an adequate loop of thread was used when suturing the vaginal cuff. Using the new vaginal suturing techniques, easy and firm vaginal cuff closure with reduced operative time relative to previous hysterectomies was achieved. The new vaginal cuff suturing techniques may convince more surgeons to perform robotic single-site hysterectomies more frequently and with greater ease. Copyright © 2018. Published by Elsevier B.V.
Onay, Ulaş; Akpınar, Sercan; Akgün, Rahmi Can; Balçık, Cenk; Tuncay, Ismail Cengiz
2013-01-01
The aim of this study was to compare new knotless single-row and double-row suture anchor techniques with traditional transosseous suture techniques for different sized rotator cuff tears in an animal model. The study included 56 cadaveric sheep shoulders. Supraspinatus cuff tears of 1 cm repaired with new knotless single-row suture anchor technique and supraspinatus and infraspinatus rotator cuff tears of 3 cm repaired with double-row suture anchor technique were compared to traditional transosseous suture techniques and control groups. The repaired tendons were loaded with 5 mm/min static velocity with 2.5 kgN load cell in Instron 8874 machine until the repair failure. The 1 cm transosseous group was statistically superior to 1 cm control group (p=0.021, p<0.05) and the 3 cm SpeedBridge group was statistically superior to the 1 cm SpeedFix group (p=0.012, p<0.05). The differences between the other groups were not statistically significant. No significant difference was found between the new knotless suture anchor techniques and traditional transosseous suture techniques.
Identification and dynamics of a cryptic suture zone in tropical rainforest
Moritz, C.; Hoskin, C.J.; MacKenzie, J.B.; Phillips, B.L.; Tonione, M.; Silva, N.; VanDerWal, J.; Williams, S.E.; Graham, C.H.
2009-01-01
Suture zones, shared regions of secondary contact between long-isolated lineages, are natural laboratories for studying divergence and speciation. For tropical rainforest, the existence of suture zones and their significance for speciation has been controversial. Using comparative phylogeographic evidence, we locate a morphologically cryptic suture zone in the Australian Wet Tropics rainforest. Fourteen out of 18 contacts involve morphologically cryptic phylogeographic lineages, with mtDNA sequence divergences ranging from 2 to 15 per cent. Contact zones are significantly clustered in a suture zone located between two major Quaternary refugia. Within this area, there is a trend for secondary contacts to occur in regions with low environmental suitability relative to both adjacent refugia and, by inference, the parental lineages. The extent and form of reproductive isolation among interacting lineages varies across species, ranging from random admixture to speciation, in one case via reinforcement. Comparative phylogeographic studies, combined with environmental analysis at a fine-scale and across varying climates, can generate new insights into suture zone formation and to diversification processes in species-rich tropical rainforests. As arenas for evolutionary experimentation, suture zones merit special attention for conservation. PMID:19203915
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.
Acoustic transmitters used in survival and telemetry studies are often surgically implanted in fish. While this is a well-established method, it has the potential to affect health, behavior, and survival, thus affecting study results. Much research has been done to try to minimize the harmful effects caused by the transmitter and tagging process. In 2009, we first investigated the use of a bi-directional knotless (barbed) suture material in juvenile Chinook salmon (Oncorhynchus tshawytscha). We found that it resulted in higher tag retention than the simple interrupted suture pattern; however, the occurrence of ulceration and redness increased. The objective of thismore » study was to refine the suturing patterns of the bi-directional knotless suture and retest suture performance in juvenile Chinook salmon. We tested the bi-directional suture using 3 different suture patterns and two needle types: 6-Point (12-mm needle circumference), Wide “N” (12-mm needle circumference), Wide “N” Knot 12 (12-mm needle circumference), and Wide “N” Knot 18 (18-mm needle circumference).« less
Sequential lift and suture technique for post-LASIK corneal striae.
Mackool, Richard J; Monsanto, Vivian R
2003-04-01
We describe a surgical technique to manage persistent corneal striae after laser in situ keratomileusis (LASIK). The sequential lift and suture technique reduces the time required for LASIK, eliminates the need to fixate the flap with forceps during suturing, and increases the accuracy of suture placement. The results in 10 eyes (9 patients) showed complete resolution of striae with improvement in subjective symptoms (glare and blurred vision) and best corrected visual acuity.
Cho, Jin Ho
2012-06-01
In cases with root tear of the medial meniscus posterior horn, the meniscus usually can be repaired by a pull out suture technique. However, there is difficulty in manipulating a suture hook via the anteromedial portal and looking through the arthroscopic camera via anterolateral portal in the narrow medial joint space at the same time. This article describes a modified simple pull out suture technique for root tear of the medial meniscus posterior horn using a posteromedial portal that provides a safe and easy handling of the suture hook. Our indications of this technique used in patients with Outerbridge 1-2 arthritic change and minimal varus axis change. Benefits of this technique are simple, less invasive, and reduced operation time by simultaneous suture with a hook via posteromedial portal and pulling of a string with grasper. It may reduce the possibility of an additional chondral or meniscal injury.
Ectocranial suture closure in Pan troglodytes and Gorilla gorilla: pattern and phylogeny.
Cray, James; Meindl, Richard S; Sherwood, Chet C; Lovejoy, C Owen
2008-08-01
The order in which ectocranial sutures undergo fusion displays species-specific variation among primates. However, the precise relationship between suture closure and phylogenetic affinities is poorly understood. In this study, we used Guttman Scaling to determine if the modal progression of suture closure differs among Homo sapiens, Pan troglodytes, and Gorilla gorilla. Because DNA sequence homologies strongly suggest that P. troglodytes and Homo sapiens share a more recent common ancestor than either does with G. gorilla, we hypothesized that this phylogenetic relationship would be reflected in the suture closure patterns of these three taxa. Results indicated that while all three species do share a similar lateral-anterior closure pattern, G. gorilla exhibits a unique vault pattern, which, unlike humans and P. troglodytes, follows a strong posterior-to-anterior gradient. P. troglodytes is therefore more like Homo sapiens in suture synostosis. Copyright 2008 Wiley-Liss, Inc.
Cantarella, Daniele; Dominguez-Mompell, Ramon; Mallya, Sanjay M; Moschik, Christoph; Pan, Hsin Chuan; Miller, Joseph; Moon, Won
2017-11-01
Mini-implant-assisted rapid palatal expansion (MARPE) appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME). Maxillary Skeletal Expander (MSE) is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Fifteen subjects (mean age of 17.2 years; range, 13.9-26.2 years) were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher's exact test was used. Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS) and at posterior nasal spine (PNS) was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS) moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05). No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0.3-4.2%). Midpalatal suture was successfully split by MSE in late adolescents, and the opening was almost perfectly parallel in a sagittal direction. Regarding the extent of transverse asymmetry of the split, on average one half of ANS moved more than the contralateral one by 1.1 mm. Pterygopalatine suture was split in its lower region by MSE, as the pyramidal process was pulled out from the pterygoid process. Patient gender and age had a negligible influence on suture opening for the age group considered in the study.
Patel, Sunil V; Paskar, David D; Nelson, Richard L; Vedula, Satyanarayana S; Steele, Scott R
2017-11-03
Surgeons who perform laparotomy have a number of decisions to make regarding abdominal closure. Material and size of potential suture types varies widely. In addition, surgeons can choose to close the incision in anatomic layers or mass ('en masse'), as well as using either a continuous or interrupted suturing technique, of which there are different styles of each. There is ongoing debate as to which suturing techniques and suture materials are best for achieving definitive wound closure while minimising the risk of short- and long-term complications. The objectives of this review were to identify the best available suture techniques and suture materials for closure of the fascia following laparotomy incisions, by assessing the following comparisons: absorbable versus non-absorbable sutures; mass versus layered closure; continuous versus interrupted closure techniques; monofilament versus multifilament sutures; and slow absorbable versus fast absorbable sutures. Our objective was not to determine the single best combination of suture material and techniques, but to compare the individual components of abdominal closure. On 8 February 2017 we searched CENTRAL, MEDLINE, Embase, two trials registries, and Science Citation Index. There were no limitations based on language or date of publication. We searched the reference lists of all included studies to identify trials that our searches may have missed. We included randomised controlled trials (RCTs) that compared suture materials or closure techniques, or both, for fascial closure of laparotomy incisions. We excluded trials that compared only types of skin closures, peritoneal closures or use of retention sutures. We abstracted data and assessed the risk of bias for each trial. We calculated a summary risk ratio (RR) for the outcomes assessed in the review, all of which were dichotomous. We used random-effects modelling, based on the heterogeneity seen throughout the studies and analyses. We completed subgroup analysis planned a priori for each outcome, excluding studies where interventions being compared differed by more than one component, making it impossible to determine which variable impacted on the outcome, or the possibility of a synergistic effect. We completed sensitivity analysis, excluding trials with at least one trait with high risk of bias. We assessed the quality of evidence using the GRADEpro guidelines. Fifty-five RCTs with a total of 19,174 participants met the inclusion criteria and were included in the meta-analysis. Included studies were heterogeneous in the type of sutures used, methods of closure and patient population. Many of the included studies reported multiple comparisons.For our primary outcome, the proportion of participants who developed incisional hernia at one year or more of follow-up, we did not find evidence that suture absorption (absorbable versus non-absorbable sutures, RR 1.07, 95% CI 0.86 to 1.32, moderate-quality evidence; or slow versus fast absorbable sutures, RR 0.81, 95% CI 0.63 to 1.06, moderate-quality evidence), closure method (mass versus layered, RR 1.92, 95% CI 0.58 to 6.35, very low-quality evidence) or closure technique (continuous versus interrupted, RR 1.01, 95% CI 0.76 to 1.35, moderate-quality evidence) resulted in a difference in the risk of incisional hernia. We did, however, find evidence to suggest that monofilament sutures reduced the risk of incisional hernia when compared with multifilament sutures (RR 0.76, 95% CI 0.59 to 0.98, I 2 = 30%, moderate-quality evidence).For our secondary outcomes, we found that none of the interventions reduced the risk of wound infection, whether based on suture absorption (absorbable versus non-absorbable sutures, RR 0.99, 95% CI 0.84 to 1.17, moderate-quality evidence; or slow versus fast absorbable sutures, RR 1.16, 95% CI 0.85 to 1.57, moderate-quality evidence), closure method (mass versus layered, RR 0.93, 95% CI 0.67 to 1.30, low-quality evidence) or closure technique (continuous versus interrupted, RR 1.13, 95% CI 0.96 to 1.34, moderate-quality evidence).Similarily, none of the interventions reduced the risk of wound dehiscence whether based on suture absorption (absorbable versus non-absorbable sutures, RR 0.78, 95% CI 0.55 to 1.10, moderate-quality evidence; or slow versus fast absorbable sutures, RR 1.55, 95% CI 0.92 to 2.61, moderate-quality evidence), closure method (mass versus layered, RR 0.69, 95% CI 0.31 to 1.52, moderate-quality evidence) or closure technique (continuous versus interrupted, RR 1.21, 95% CI 0.90 to 1.64, moderate-quality evidence).Absorbable sutures, compared with non-absorbable sutures (RR 0.49, 95% CI 0.26 to 0.94, low-quality evidence) reduced the risk of sinus or fistula tract formation. None of the other comparisons showed a difference (slow versus fast absorbable sutures, RR 0.88, 95% CI 0.05 to 16.05, very low-quality evidence; mass versus layered, RR 0.49, 95% CI 0.15 to 1.62, low-quality evidence; continuous versus interrupted, RR 1.51, 95% CI 0.64 to 3.61, very low-quality evidence). Based on this moderate-quality body of evidence, monofilament sutures may reduce the risk of incisional hernia. Absorbable sutures may also reduce the risk of sinus or fistula tract formation, but this finding is based on low-quality evidence.We had serious concerns about the design or reporting of several of the 55 included trials. The comparator arms in many trials differed by more than one component, making it impossible to attribute differences between groups to any one component. In addition, the patient population included in many of the studies was very heterogeneous. Trials included both emergency and elective cases, different types of disease pathology (e.g. colon surgery, hepatobiliary surgery, etc.) or different types of incisions (e.g. midline, paramedian, subcostal).Consequently, larger, high-quality trials to further address this clinical challenge are warranted. Future studies should ensure that proper randomisation and allocation techniques are performed, wound assessors are blinded, and that the duration of follow-up is adequate. It is important that only one type of intervention is compared between groups. In addition, a homogeneous patient population would allow for a more accurate assessment of the interventions.
Sarhan, A; Dua, H.; Beach, M.
2000-01-01
BACKGROUND/AIMS—Post-keratoplasty astigmatism can be managed by selective suture removal in the steep axis. Corneal topography, keratometry, and refraction are used to determine the steep axis for suture removal. However, often there is a disagreement between the topographically determined steep axis and sutures to be removed and that determined by keratometry and refraction. The purpose of this study was to evaluate any difference in the effect of suture removal, on visual acuity and astigmatism, in patients where such a disagreement existed. METHODS—37 cases (from 37 patients) of selective suture removal after penetrating keratoplasty, were included. In the first group "the disagreement group" (n=15) there was disagreement between corneal topography, keratometry, and refraction regarding the axis of astigmatism and sutures to be removed. In the second group "the agreement group" (n=22) there was agreement between corneal topography, keratometry, and refraction in the determination of the astigmatic axis and sutures to be removed. Sutures were removed according to the corneal topography, at least 5 months postoperatively. Vector analysis for change in astigmatism and visual acuity after suture removal was compared between groups. RESULTS—In the disagreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism after suture removal was 3.45 (SD 2.34), 3.57 (1.63), and 2.83 (1.68) dioptres, respectively. In the agreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism was 5.95 (3.52), 5.37 (3.29), and 4.71 (2.69) dioptres respectively. This difference in the vector corrected change in astigmatism between groups was statistically significant, p values of 0.02, 0.03, and 0.03 respectively. Visual acuity changes were more favourable in the agreement group. Improvement or no change in visual acuity occurred in 90.9% in the agreement group compared with 73.3% of the disagreement group. CONCLUSIONS—Agreement between refraction, keratometry, and topography was associated with greater change in vector corrected astigmatism and was an indicator of good prognosis. Disagreement between refraction, keratometry, and topography was associated with less vector corrected change in astigmatism, a greater probability of decrease in visual acuity, and a relatively poor outcome following suture removal. However, patients in the disagreement group still have a greater chance of improvement than worsening, following suture removal. PMID:10906087
Crisp, Catrina C; Herfel, Charles V; Pauls, Rachel N; Westermann, Lauren B; Kleeman, Steven D
2016-01-01
This study aimed to characterize pertinent anatomy relative to the sacral suture placed at time of robotic sacrocolpopexy using postoperative computed tomography and magnetic resonance imaging. A vascular clip was placed at the base of the sacral suture at the time of robotic sacrocolpopexy. Six weeks postoperatively, subjects returned for a computed tomography scan and magnetic resonance imaging. Ten subjects completed the study. The middle sacral artery and vein coursed midline or to the left of midline in all the subjects. The left common iliac vein was an average of 26 mm from the sacral suture. To the right of the suture, the right common iliac artery was 18 mm away. Following the right common iliac artery to its bifurcation, the right internal iliac was on average 10 mm from the suture. The bifurcations of the inferior vena cava and the aorta were 33 mm and 54 mm further cephalad, respectively.The right ureter, on average, was 18 mm from the suture. The thickness of the anterior longitudinal ligament was 2 mm.The mean angle of descent of the sacrum was 70 degrees. Lastly, we found that 70% of the time, a vertebral body was directly below the suture; the disc was noted in 30%. We describe critical anatomy surrounding the sacral suture placed during robotic sacrocolpopexy. Proximity of both vascular and urologic structures within 10 to 18 mm, as well as anterior ligament thickness of only 2 mm highlights the importance of adequate exposure, careful dissection, and surgeon expertise.
Zhou, Feng; Fang, Zhen-Qiang; Zhang, Yuan-Ning; Chen, Wei; Liu, Yong-Liang; Ye, Gang
2010-08-01
To compare the mechanical and sutured ureteroneocystostomy in a canine model. In 18 dogs, extravesical ureteroneocystostomy on 1 side was randomly assigned to end-to-side anastomosis performed with a titanium ring-pin stapler or interrupted absorbable sutures. To create the antireflux tunnel, the longitudinal line of the muscle layer was closed over the implanted ureter with titanium clips or sutures. At 3 months postoperatively, renal ultrasonography, intravenous urography, ascending cystography, the Whitaker test, and the macroscopic and microscopic results were assessed. The ureteroneocystostomy with the ring pin stapler and the antireflux tunnel construction with titanium clips had a 100% technical success rate. Compared with manual suturing anastomosis, the suture-free technique took a significantly shorter time and resulted in slightly, but not significantly, less ureteral obstruction after 3 months. One dog in group 2 had evidence of ureteral dilation and hydronephrosis compared with the normal contralateral side. No signs of stone formation, urinary cyst, or fistulas were found after either closure method. None of the 18 dogs demonstrated vesicoureteral reflux. Histologic examination showed no signs of acute inflammation or marked fibrosis in any of the 18 specimens. Moreover, the intrapelvic pressure in group 1 was approximately similar to that of the normal contralateral side. Ureteroneocystostomy performed with a titanium ring-pin stapler is feasible and faster than using conventional sutures. This suture-free technique is simple and safe, with possibly lower complication rates than a nonstented suture technique. Additional studies with a longer follow-up duration are needed to confirm these results. Copyright 2010. Published by Elsevier Inc.
Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.
Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D
2011-10-01
To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.
Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.
Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher
2016-03-01
To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
In vitro evaluation of square and surgeon's knots in large gauge suture.
Gillen, Alex M; Munsterman, Amelia S; Farag, Ramsis; Coleridge, Matthew O D; Hanson, R Reid
2017-02-01
To investigate the strength and size of surgeon's and square knots for starting and ending continuous suture lines using large gauge suture. In vitro mechanical study. Knotted suture. Surgeon's and square knots were tested using 2 and 3 USP polyglactin 910 and 2 USP polydioxanone under linear tension on a universal testing machine. Failure mode and knot holding capacity (KHC) were recorded, and relative knot security (RKS) was calculated as a percentage of KHC. Comparisons were made between number of throws, suture size, suture type, and knot types. Knot volume and weight were assessed by a digital micrometer and balance, respectively. There were no significant differences in KHC (P = .295), RKS (P = .307), volume (P = .128), or weight (P = .310) between square and surgeon's knots at the start or end of suture lines with the same number of throws and suture type. A minimum of 6 throws were required for start knots and 7 throws at end knots to prevent unraveling. Knots tied with 3 polyglactin 910 were strongest (P < .001) and 2 polyglactin 910 produced knots with higher KHC and RKS than 2 polydioxanone (P < .001). No consistent differences were detected between knots types tied with the same suture material; however, number of throws affected KHC and RKS up to 6 throws in start or 7 throws in end knots. The configuration of square and surgeon's knots performed at the end of a continuous line alters their KHC, supporting the use of additional throws for knot security. © 2017 The American College of Veterinary Surgeons.
Comparison of holding strength of suture anchors for hepatic and renal parenchyma.
Ames, Caroline D; Perrone, Juan M; Frisella, Alison J; Morrissey, Kevin; Landman, Jaime
2005-12-01
Various laparoscopic devices have been described for suture anchoring during solidorgan parenchymal closure. Application of these devices expedites the closure of parenchymal defects and minimizes ischemia time. We compared different technologies as suture anchors for parenchymal closure. A tensometer was used to determine the amount of tension necessary to dislodge each of five different clips from Vicryl suture alone or against two different substrates (fresh pig kidney and liver) with and without an intervening pledget. The clips investigated were the Lapra-Ty (Ethicon), Endoclip II (US Surgical), small Horizon Ligating Clips (Weck), Hem-o-lok Medium Polymer Clips (Week), and a novel Suture-clip (Applied Medical). ANOVA and two-sided Fisher's exact test provided statistical analysis. The force required to dislodge the Lapra-Ty clip from bare suture for both 0 and 1 Vicryl (7.0 N) was approximately fourfold the force required to dislodge the Endoclips or the 5-mm or 10-mm Hem-o-lok clips (p<0.01). When clips were applied to suture running through renal or liver parenchyma, the novel Suture-clip required the greatest tension to dislodge (P<0.01), followed by the Horizon and Lapra-Ty clips. There were no statistically significant differences in the tension required to dislodge a given clip from the two parenchymal substrates or in the presence or absence of a pledget. In our experimental model, the Suture-clip, Lapra-Ty, and Horizon clips required significantly greater tension to dislodge than the Hem-o-lok and Endoclip clips. The addition of a pledget did not improve tension resistance.
Stretch force guides finger-like pattern of bone formation in suture
Kou, Xiao-Xing; Zhang, Ci; Zhang, Yi-Mei; Cui, Zhen; Wang, Xue-Dong; Liu, Yan; Liu, Da-Wei; Zhou, Yan-Heng
2017-01-01
Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling with the direction of stretch force. Inclined force led to inclined finger-like bones formation and deflection of bilateral maxillae. Additionally, heavily compressive force caused fracture of finger-like bones in the sutures. These data together proposed the special finger-like pattern of bone formation in sutures guided by stretch force, providing important implications for maxillary expansion. PMID:28472133
Effect of Adhesive Strips and Dermal Sutures vs Dermal Sutures Only on Wound Closure
Custis, Trenton; Armstrong, April W.; King, Thomas H.; Sharon, Victoria R.; Eisen, Daniel B.
2016-01-01
IMPORTANCE Although applying adhesive strips to a wound closure has been shown to have outcomes equivalent to those with cuticular suturing, it is unknown whether adhesive strips provide additional benefit compared with dermal suturing alone. OBJECTIVE To determine whether the addition of adhesive strips to a wound closed with buried interrupted subcuticular sutures improves outcomes following wound closure. DESIGN, SETTING, AND PARTICIPANTS A prospective, randomized split-wound intervention was conducted between November 14, 2013, and May 16, 2014, in patients who underwent cutaneous surgical procedures at the University of California, Davis, outpatient dermatology clinic. Fifty-seven patients 18 years or older with postoperative defects of at least 3 cm, resulting from either Mohs micrographic surgical procedures or surgical excision, were screened for participation. Nine patients were excluded and 48 were enrolled. INTERVENTIONS Half of each wound was randomized to receive buried interrupted subcuticular sutures and overlying adhesive strips and the other half received buried interrupted subcuticular sutures only. MAIN OUTCOMES AND MEASURES At 3 months’ follow-up, each patient and 2 blinded observers evaluated the wound using the Patient Observer Scar Assessment Scale. RESULTS The total mean (SD) Patient Observer Scar Assessment Scale score for observers for the side that received a combination of adhesive strips and buried interrupted subcuticular suturing (12.3 [4.8]) and the side that received sutures only (12.9 [6.3]) did not differ significantly at 3 months (P = .32). There was no significant difference in the total patient assessment scale score between the combination closure (14.0 [7.6]) and sutures only (14.7 [7.6]) sides at 3 months (P = .39). There was also no significant difference between the 2 closure methods in terms of mean (SD) scar width (both methods: 1.1 [0.8] mm, P = .89) at follow-up. CONCLUSIONS AND RELEVANCE Combination closure with adhesive strips and buried interrupted subcuticular suturing was not significantly associated with improved overall scar assessment compared with buried interrupted subcuticular suturing alone when evaluated by blinded observers or the patients themselves. Our results do not support the use of adhesive strips as a means to improve cosmetic outcomes or reduce scar width. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01979497 PMID:25875131
Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.
Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L
2011-08-01
Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA. Copyright © 2011 Elsevier Inc. All rights reserved.
The posterior auricular muscle: a useful anatomical landmark for otoplasty.
Stephen, C; Lowrie, A G
2017-05-01
The correct anatomical placement of conchomastoid sutures during suture otoplasty can sometimes prove challenging. If the suture vector is inaccurate, reduction can be difficult and this may lead to malrotation of the pinna. This paper describes the adoption of the auricularis posterior muscle, which runs from the mastoid to the concha and whose function is to adduct the pinna, as a marker for conchomastoid suture placement. The muscle is easily identified and dissected, providing a landmark for the placement of sutures onto the adjacent concha and mastoid fascia. This allows for an anatomical reduction of the pinna. It is believed that this approach will prove useful to the otoplasty surgeon.
Molecular genetics of craniosynostosis
NASA Astrophysics Data System (ADS)
Caterine; Auerkari, Elza Ibrahim
2018-03-01
Tight regulation process and complex interplay occur along the osteogenic interfaces of the cranial sutures in normal growth and development of the skull. Cranial sutures serve as sites of bone growth while maintaining a state of patency to accommodate the developing brain. Cranial sutures are fibro-cellular structures that separate the rigid plates of the skull bones. Premature fusion of one or more cranial sutures leads to a condition known as craniosynostosis. Craniosynostosis is one of the most common craniofacial anomalies with a prevalence of 1 in 2,500 newborns. Several genes have been identified in the pathogenesis of craniosynostosis. Molecular signaling events and the intracellular signal transduction pathways implicated in the suture pathobiology will provide a useful approach for therapeutic targeting.
Zhang, Gang; Zhang, Fusheng; Zhu, Mei; Zhang, Wenlong; Fan, Quanxin; Zou, Chengwei; Wang, Anbiao
2011-10-01
Since 2008, 28 patients with congenital mitral regurgitation have undergone mitral valve repair with a modified edge-to-edge technique at our institution. The regurgitant mitral leaflet was sutured with a pledget-reinforced, horizontal mattress suture with No. 4-0 polypropylene on the ventricle side and a pledget-reinforced mattress suture with Gore-Tex sutures (W.L. Gore & Associates, Flagstaff, AZ) and Dacron pledgets (Chest, Shanghai) placed on the anterior and posterior annulus corresponding to the edge-to-edge suturing site. Early results are encouraging, but a longer follow-up is needed. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bacterial Adherence to High Tensile-Strength Sutures.
2011-06-01
8063/10238/$00.00 doi:10.1016/j.arthro.2011.02.003 834 Arthroscopy : The Journal of Arthroscopic and Related Surgery, Vol 27, No 6 (June), 2011: pp 834...Herbert MA, Coons DA, Boothby MH. Sutures and suture anchors—Update 2006. Arthroscopy 2006;22:1063- 1069. 2. Barber FA, Herbert MA, Beavis RC. Cyclic... Arthroscopy 2007;23:884-888. 5. Wust DM, Meyer DC, Favre P, Gerber C. Mechanical and handling properties of braided polyblend polyethylene sutures in
Use of adhesive surgical tape with the absorbable continuous subcuticular suture.
Kolt, Jeremy D
2003-08-01
The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.
Gonçalves, Antonio José; de Souza, J A L; Menezes, M B; Kavabata, N K; Suehara, A B; Lehn, C N
2009-11-01
The extension of the surgery and closure type of the pharynx can be the determinants in the pharyngocutaneous fistula development. The objective of the study is to evaluate the incidence of pharingocutaneous salivary fistulae after total laryngectomies comparing manual and mechanical sutures. The study is designed as non-randomized, prospective clinical study. Sixty patients with squamous cell carcinoma were submitted to total laryngectomies. In 30 cases, the linear stapler (75 mm) closure (surgical technique described in details) and in other 30 cases manual suture was used. The cases of mechanical suture were prospective and consecutive and the cases of manual suture were a review series of patients who underwent a manual suture of pharynx, in the same period of time. The statistical analysis between the two groups concluded that both were comparable. Fistulae incidence was 6.7% (2/30) in the group with the mechanical suture and 36.7% (11/30) in the group with manual suture closure, presenting a significant difference (p = 0.0047). The total laryngectomy with mechanical closure is an easy and fast learning technique, allowing watertight closure of the pharynx with a low risk of contamination of the surgical field. It is an assured method, even in previously irradiated patients, since we respect the limits of its indication regarding the extension of primary tumor that must be confirmed by previous suspension laryngectomy performed in the operating room.
Parikh, Punam P; Tashiro, Jun; Wagenaar, Amy E; Curbelo, Miosotys; Perez, Eduardo A; Neville, Holly L; Hogan, Anthony R; Sola, Juan E
2018-04-01
Appendiceal ligation during pediatric laparoscopic appendectomy (LA) may be performed using looped suture versus stapler. Controversy regarding the utility of either method exists. Clinical outcomes and cost analysis of LA with both methods were compared. All pediatric LA were performed from fiscal years 2013 and 2014 by two pediatric surgeons. While one surgeon used looped suture, the other used stapler exclusively. chi-Square tests were performed to analyze associations. Two hundred thirty-eight cases were analyzed where looped suture versus stapler LA was performed in 46% and 54% of patients, respectively. Operating room costs were $317.10 and $707.12/person for looped suture and stapler LA, respectively (P<0.0001). Difference in cost of $390.02/person was attributed solely to ligation type. On bivariate analysis, rate of in-hospital complications, length of stay, return-to-ER and readmission within 30 days did not significantly differ between groups. A comparative analysis of looped suture versus stapler device during LA for pediatric appendicitis revealed that postoperative complications, length of stay, ER visits and readmissions were not significantly different. Looped suture LA was significantly more cost efficient than stapler LA. In pediatric appendicitis, appendiceal ligation during LA may be performed safely and cost effectively with looped suture versus stapler. Cost effectiveness LEVEL OF EVIDENCE: III. Copyright © 2017 Elsevier Inc. All rights reserved.
[Clinical application of biofragmentable anastomosis ring for intestinal anastomosis].
Ye, Feng; Lin, Jian-jiang
2006-11-01
To compare the efficacy of the biofragmentable anastomotic ring (BAR) with conventional hand-sutured and stapling techniques,and to evaluate the safety and applicability of the BAR in intestinal anastomosis. The totol of 498 patients performed intestinal anastomosis from January 2000 to November 2005 were allocated to BAR group (n=186), hand-sutured group (n=177) and linear cutter group (n=135). The operative time, postoperative convalescence and corresponding complication were recorded. Postoperative anastomotic inflammation and anastomotic stenosis were observed during half or one year follow-up of 436 patients. The operative time was (102 +/- 16) min in the BAR group, (121 +/- 15) min in the hand-sutured group, and (105 +/- 18 ) min in the linear cutter group. The difference was significant statistically (P <0.05). The operative time in BAR group and linear cutter group was shorter than hand-sutured group. One case of anastomotic leakage was noted in the BAR group, one case in the hand-sutured group, and none in the linear cutter group. They were cured by conservative methods. One case of anastomotic obstruction happened in the BAR group, one case in the hand-sutured group. Two of them were cured by conservative methods. Two cases of anastomotic obstruction happened in the hand-sutured group. However, one of them required reoperation to remove the obstruction. In the BAR, hand-sutured and the linear cutter group, the postoperative first flatus time was (67.2+/- 4.6) h, (70.2 +/- 5.8) h and (69.2 +/- 6.2)h, respectively. No significant differences were observed among three groups(P > 0.05). The rate of postoperative anastomotic inflammation was 3.0 % (5/164) in the BAR group, 47.8 % (76/159) in hand-sutured group and 7.1 % (8/113) in the linear cutter group. The difference was significant statistically (P <0.05). The rate of postoperative anastomotic inflammation in the BAR group and in the linear cutter group was less than that in hand-sutured group. BAR is one of rapid,safe and effective methods in intestinal anastomosis. It has less anastomotic inflammatory reaction than hand-sutured technique. It should be considered equal to manual and stapler methods.
Guidelines for Water Quality Laboratory Operations.
1985-07-01
Semiannually sample cell pressure gauge Autoclaves and Check sterilization effectiveness Daily sterilizers (e.g., B. stearothermophilus , color-indicator...container should have been previously cleaned with chromic acid solution as described previously. Treat the container caps similarly. C. Sterilization . For...microbiological analyses, sterilize the container and its stopper/cap by autoclaving at 121*C for 15 min or by dry heat at 180C for 2 hr. Heat-sensitive
PLURAL METALLIC COATINGS ON URANIUM AND METHOD OF APPLYING SAME
Gray, A.G.
1958-09-16
A method is described of applying protective coatings to uranlum articles. It consists in applying chromium plating to such uranium articles by electrolysis in a chromic acid bath and subsequently applying, to this minum containing alloy. This aluminum contalning alloy (for example one of aluminum and silicon) may then be used as a bonding alloy between the chromized surface and an aluminum can.
A spectroscopic study of the chromatic properties of GafChromicEBT3 films.
Callens, M; Crijns, W; Simons, V; De Wolf, I; Depuydt, T; Maes, F; Haustermans, K; D'hooge, J; D'Agostino, E; Wevers, M; Pfeiffer, H; Van Den Abeele, K
2016-03-01
This work provides an interpretation of the chromatic properties of GafChromicEBT3 films based on the chemical nature of the polydiacetylene (PDA) molecules formed upon interaction with ionizing radiation. The EBT3 films become optically less transparent with increasing radiation dose as a result of the radiation-induced polymerization of diacetylene monomers. In contrast to empirical quantification of the chromatic properties, less attention has been given to the underlying molecular mechanism that induces the strong decrease in transparency. Unlaminated GafChromicEBT3 films were irradiated with a 6 MV photon beam to dose levels up to 20 Gy. The optical absorption properties of the films were investigated using visible (vis) spectroscopy. The presence of PDA molecules in the active layer of the EBT3 films was investigated using Raman spectroscopy, which probes the vibrational modes of the molecules in the layer. The vibrational modes assigned to PDA's were used in a theoretical vis-absorption model to fit our experimental vis-absorption spectra. From the fit parameters, one can assess the relative contribution of different PDA conformations and the length distribution of PDA's in the film. Vis-spectroscopy shows that the optical density increases with dose in the full region of the visible spectrum. The Raman spectrum is dominated by two vibrational modes, most notably by the ν(C≡C) and the ν(C=C) stretching modes of the PDA backbone. By fitting the vis-absorption model to experimental spectra, it is found that the active layer contains two distinct PDA conformations with different absorption properties and reaction kinetics. Furthermore, the mean PDA conjugation length is found to be 2-3 orders of magnitude smaller than the crystals PDA's are embedded in. Vis- and Raman spectroscopy provided more insight into the molecular nature of the radiochromic properties of EBT3 films through the identification of the excited states of PDA and the presence of two PDA conformations. The improved knowledge on the molecular composition of EBT3's active layer provides a framework for future fundamental modeling of the dose-response.
Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q
2014-03-01
We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p < 0.05) gap formation and less (p < 0.05) longitudinal strain than did the 10-mm group. Ultimate load (293.6 vs. 148.9 N) and energy to ultimate load (2,563 vs. 1,472 N-mm) were greater (p < 0.001) for the 10-mm group than the 4-mm group. All tendons repaired with 4-mm suturing failed at the suture-tendon interface, with sutures pulling through the tendon, whereas the suture itself failed before the tendon did in seven of the ten specimens in the 10-mm group. Whereas a 4-mm bite fixed the tendon more tightly but at the cost of decreased ultimate strength, a 10-mm bite conveyed greater ultimate strength but with increased gap and strain. These results suggest that for the conventional double-row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.
Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M
2008-11-01
The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P < 0.001). The ultimate tensile strength in double-row specimens was significantly higher than in others (P < 0.001). There was no significant variation in using different suture material (P > 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.
Liu, Rui Wen; Lam, Patrick Hong; Shepherd, Henry M.; Murrell, George A. C.
2017-01-01
Background: Rotator cuff retears after surgical repair are associated with poorer subjective and objectives clinical outcomes than intact repairs. Purpose: The aims of this study were to (1) examine the biomechanical differences between rotator cuff repair using No. 2 suture and tape in an ovine model and (2) compare early clinical outcomes between patients who had rotator cuff repair with tape and patients who had repair with No. 2 suture. Study Design: Controlled laboratory study and cohort study; Level of evidence, 3. Methods: Biomechanical testing of footprint contact pressure and load to failure were conducted with 16 ovine shoulders using a tension band repair technique with 2 different types of sutures (No. 2 suture [FiberWire; Arthrex] and tape [FiberTape; Arthrex]) with the same knotless anchor system. A retrospective study of 150 consecutive patients (tape, n = 50; suture, n = 100) who underwent arthroscopic rotator cuff repair by a single surgeon with tear size larger than 1.5 × 1 cm was conducted. Ultrasound was used to evaluate the repair integrity at 6 months postsurgery. Results: Rotator cuff repair using tape had greater footprint contact pressure (mean ± standard error of the mean, 0.33 ± 0.03 vs 0.11 ± 0.3 MPa; P < .0001) compared with repair using No. 2 sutures at 0° abduction with a 30-N load applied across the repaired tendon. The ultimate failure load of the tape repair was greater than that for suture repair (217 ± 28 vs 144 ± 14 N; P < .05). The retear rate was similar between the tape (16%; 8/50) and suture groups (17%; 17/100). Conclusion: Rotator cuff repair with the wider tape compared with No. 2 suture did not affect the retear rate at 6 months postsurgery, despite having superior biomechanical properties. PMID:28451619
A new suturing instrument that allows the use of microsuture at laparoscopy.
McComb, P F
1992-04-01
A surgeon at University Hospital-Shaughnessy Site in Vancouver, British Columbia in Canada has used a new suturing instrument that enters the peritoneal cavity to permit microsutures of size 6-0 or less and 75 cm in length during laparoscopy. Surgeons can use this instrument to perform female sterilizations as well as removal of the gall gladder and appendix and repair of the bowel, bladder, and ureteric injuries. As of April 1992, the suturing instrument was not yet commercially available. It consists of a partial hollow 30 cm x 2 mm (inside diameter) tube with the end that does not enter the peritoneal cavity being occluded. The suturing instrument enters the peritoneal cavity via a standard 5 mm deflection valved trocar sleeve with a 3 mm reduction sleeve or with a 3 mm inside diameter occlusive rubber washer instead of the standard 5 mm washer. The suture must have sufficient tensile strength and have low coefficients for static and for sliding surface frictions. Once the suture and needle are inside the body, forceps which have entered via another cannula detach them from the suturing instrument. A 3 mm laproscopic needle driver replaces the suturing instrument at this point. The surgeon guides the needle through the intended tissues and then withdrawn with the needle driver through the 5 mm sleeve. The surgeon ties the knot outside the body and slides it down the length of the suture to apply it to the tissue. He/she repeats this 1 more time. Scissors inserted through the other opening then cut the suture. Once mastered, this process takes only a few minutes to complete. In all 11 cases or restoration of uterine tube patency done by the surgeon in Vancouver using the new technique, tubal patency has not been hindered. 2 assessed sterilization reversals have been successful.
Smith, Patrick A; Bozynski, Chantelle C; Kuroki, Keiichi; Henrich, Sarah M; Wijdicks, Coen A; Cook, James L
2018-05-31
The purpose of this study was to assess intra-articular use of a nonabsorbable braided suture tape for its biocompatibility when implanted adjacent to the native anterior cruciate ligament (ACL) in a canine model. Establishing biocompatibility of suture tape in the knee is an important foundational step for clinicians considering use of suture tape augmentation for ACL reconstruction or repair. The study hypothesis was that a nonabsorbable braided suture tape would be biocompatible in the knee with no resultant adverse functional consequences, and no significant intra-articular synovial reactions or articular cartilage degeneration attributable to direct exposure to the suture tape, whether intact or transected. Nonabsorbable braided suture tape was arthroscopically implanted adjacent to the native ACL of dogs ( n = 6). The suture was intact in half of the dogs and was transected in the other half as a "worst-case" scenario. Dogs were assessed for postoperative complications and morbidity. Arthroscopic grading of synovium and cartilage was performed at 4 and 6 months. Histologic assessments were performed at the 6-month endpoint and compared with the ACL partial tear ( n = 9) and ACL reconstruction ( n = 5) cohorts as well as historical sham controls. No postoperative complications were noted. No animal developed lameness or clinical dysfunction, and there were no severe inflammatory or immune responses, cartilage erosions, or premature osteoarthritis noted. Arthroscopic assessments revealed no to mild synovitis and no apparent cartilage damage in either group. Histologically, both the intact and transected suture tape groups were associated with significantly ( p ≤ 0.05) less synovial and articular cartilage pathology compared with the partial ACL transection and patellar bone-tendon-bone ACL autograft reconstruction cohorts, and matched historical sham controls. The hypothesis was accepted as study results support the biocompatibility of suture tape in the canine knee. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Suture repair of umbilical hernia during caesarean section: a case-control study.
Steinemann, D C; Limani, P; Ochsenbein, N; Krähenmann, F; Clavien, P-A; Zimmermann, R; Hahnloser, D
2013-08-01
The objective of this study was to investigate the additional burdens in terms of pain, prolongation of surgery and morbidity which is added to elective caesarean section if umbilical hernia suture repair is performed simultaneously. Secondly, patient's satisfaction and hernia recurrence rate were assessed. Consecutive women with symptomatic umbilical hernia undergoing internal or external suture repair during elective caesarean were included in this retrospective cohort-control study. Data on post-operative pain, duration of surgery and morbidity of a combined procedure were collected. These patients were matched 1:10 to women undergoing caesarean section only. Additionally, two subgroups were assessed separately: external and internal suture hernia repair. These subgroups were compared for patient's satisfaction, cosmesis, body image and recurrence rate. Fourteen patients with a mean age of 37 years were analysed. Internal suture repair (n = 7) prolonged caesarean section by 20 min (p = 0.001) and external suture repair (n = 7) by 34 min (p < 0.0001). Suture repair did not increase morphine use (0.38 ± 0.2 vs. 0.4 ± 02 mg/kg body weight), had no procedure-related morbidity and prolonged hospitalization by 0.5 days (p = 0.01). At a median follow-up of 37 (5-125) months, two recurrences in each surgical technique, internal and external suture repair, occurred (28 %). Body image and cosmesis score showed a higher level of functioning in internal suture repair (p = 0.02; p = 0.04). Despite a high recurrence rate, internal suture repair of a symptomatic umbilical hernia during elective caesarean section should be offered to women if requested. No additional morbidity or scar is added to caesarean section. Internal repair is faster, and cosmetic results are better, additional skin or fascia dissection is avoided, and it seems to be as effective as an external approach. Yet, women must be informed on the high recurrence rate.
Music experience influences laparoscopic skills performance.
Boyd, Tanner; Jung, Inkyung; Van Sickle, Kent; Schwesinger, Wayne; Michalek, Joel; Bingener, Juliane
2008-01-01
Music education affects the mathematical and visuo-spatial skills of school-age children. Visuo-spatial abilities have a significant effect on laparoscopic suturing performance. We hypothesize that prior music experience influences the performance of laparoscopic suturing tasks. Thirty novices observed a laparoscopic suturing task video. Each performed 3 timed suturing task trials. Demographics were recorded. A repeated measures linear mixed model was used to examine the effects of prior music experience on suturing task time. Twelve women and 18 men completed the tasks. When adjusted for video game experience, participants who currently played an instrument performed significantly faster than those who did not (P<0.001). The model showed a significant sex by instrument interaction. Men who had never played an instrument or were currently playing an instrument performed better than women in the same group (P=0.002 and P<0.001). There was no sex difference in the performance of participants who had played an instrument in the past (P=0.29). This study attempted to investigate the effect of music experience on the laparoscopic suturing abilities of surgical novices. The visuo-spatial abilities used in laparoscopic suturing may be enhanced in those involved in playing an instrument.
Assessment potential of a new suture simulator in laparoscopic surgical skills training.
Takeoka, Tomohira; Takiguchi, Shuji; Uemura, Munenori; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Kurokawa, Yukinori; Makino, Tomoki; Yamasaki, Makoto; Mori, Masaki; Yuichiro Doki, And
2017-12-01
The skills necessary for performing effective laparoscopic suturing are difficult to acquire; as a result, simulators for learning these skills are rapidly becoming integrated into surgical training. The aim of the study was to verify whether a new hybrid simulator has the potential to measure skill improvement in young, less experienced gastroenterological surgeons. The study included 12 surgeons (median age, 29 (27-38)] years; 11 men (91.7%), one woman (8.3%)) who participated in a two-day laparoscopic training seminar. We used the new simulator before and after the program to evaluate individual performance. Skills were evaluated using five criteria: volume of air pressure leakage, number of full-thickness sutures, suture tension, wound area, and performance time. Air pressure leakage was significantly higher after than before the training (p = .027). The number of full-thickness sutures was significantly higher post-training (p < .01). Suture tension was significantly less post-training (p = .011). Wound opening areas were significantly smaller post-training (p = .018). Performance time was significantly shorter post-training (p = .032). Our study demonstrated the assessment quality of this new laparoscopic suture simulator.
Takazawa, Shinya; Ishimaru, Tetsuya; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-11-01
We have developed a thin needle driver with multiple degrees-of-freedom (DOFs) for neonatal laparoscopic surgery. The tip of this needle driver has three DOFs for grasp, deflection and rotation. Our aim was to evaluate the performance of the multi-DOF needle driver in vertical plane suturing. Six pediatric surgeons performed four directional suturing tasks in the vertical plane using the multi-DOF needle driver and a conventional one. Assessed parameters were the accuracy of insertion and exit, the depth of suture, the inclination angle of the needle and the force applied on the model. In left and right direction sutures, the inclination angle of the needle with the multi-DOF needle driver was significantly smaller than that with the conventional one (p = 0.014, 0.042, respectively). In left and right direction sutures, the force for pulling the model with the multi-DOF needle driver was smaller than that with the conventional one (p = 0.036, 0.010, respectively). This study showed that multi-directional suturing on a vertical plane using the multi-DOF needle driver had better needle trajectories and was less invasive as compared to a conventional needle driver.
Adam, Ahmed; Sookram, Jayveer
2018-01-01
Background To describe a novel bladder fixation technique for use during endoscopic vesicostomy button insertion. Methods After standard cystoscopic visualization of the bladder, a standard 18 G intravenous cannula was inserted into the bladder. A non-absorbable suture thread was placed through this intravenous cannula under cystoscopic vision. The proximal end of the suture was then removed using standard ureteroscopic grasping forceps (3 Fr) through another needle (15 G) inserted next to the initial puncture site (following a path at 30 degrees from the initial puncture tract) into the bladder. The suture ends were brought out of the bladder and tied at the skin level, 2 cm from the intended vesicostomy site. Sutures were removed on the second postoperative day. Results This fixation technique allows for adequate fixation of the bladder dome to the anterior abdominal wall. These sutures also have less potential for cutaneous scarring and pain. No complications were reported. Conclusion This simple fixation technique is easily performed using materials found in every urology suite. It also avoids the skills required with other previously reported fixation suture techniques, and can also be utilized for bladder fixation in cases of vesicoscopic laparoscopic or robotic assisted laparoscopic procedures. PMID:29692696
Cha, Dong Min; Kim, Kyeong Hwan; Choi, Hyuk Jin; Wee, Won Ryang
2012-01-01
Purpose To compare the effect of using fibrin glue or 10-0 nylon sutures on the clinical outcome of patients undergoing pterygium excision and conjunctival autografting. Methods We retrospectively reviewed the medical records of 52 eyes from 46 patients who underwent pterygium excision and conjunctival autografting and were followed up for more than 3 months. The operation duration, postoperative inflammation, complications, and recurrence rates were compared between groups of 20 patients (22 eyes) for whom fibrin glue was used (fibrin glue group) and 26 patients (30 eyes) for whom suturing was performed with 10-0 nylon (suture group) in pterygium excision and conjunctival autografting. Results The operation duration was 27.71 (5.22) minutes in the fibrin glue group and 43.30 (8.18) minutes in the suture group (p = 0.000). Seven days after the operation, the fibrin glue group showed milder conjunctival inflammation than the suture group (p = 0.000). Postoperative complications and corneal recurrence rates were not statistically different between the two groups. Conclusions The use of fibrin glue in pterygium excision with conjunctival autografting is likely to be a more effective, safer procedure than suturing. PMID:23204794
21 CFR 878.5000 - Nonabsorbable poly(ethylene terephthalate) surgical suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable poly(ethylene terephthalate... Devices § 878.5000 Nonabsorbable poly(ethylene terephthalate) surgical suture. (a) Identification. Nonabsorbable poly(ethylene terephthalate) surgical suture is a multifilament, nonabsorbable, sterile, flexible...
Taube, M.; Porter, R. J.; Lord, P. H.
1983-01-01
We have conducted a controlled trial to compare skin closure using conventional interrupted sutures with a combination of subcuticular suture and sterile Micropore tape in 169 patients undergoing appendicectomy, inguinal herniorrhaphy, or saphenofemoral ligation. We have found that the combination technique consistently gives a better cosmetic result and that the tape acts well as a dressing, is convenient, and is well tolerated by patients. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:6344732
Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan
2017-09-01
Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.
Complications in posteromedial arthroscopic suture of the medial meniscus.
Jan, N; Sonnery-Cottet, B; Fayard, J-M; Kajetanek, C; Thaunat, M
2016-12-01
All-inside posteromedial suture for lesions of the posterior horn of the medial meniscus in anterior cruciate ligament (ACL) repair provides effective freshening and good healing. The posteromedial portal provides satisfactory healing rates without increasing morbidity or complications rates. Intra- and postoperative complications were collected for a consecutive single-center series of 132 patients undergoing posteromedial hook suture of the medial meniscus in ACL repair. Meniscal healing was assessed as the rate of recurrence of symptomatic medial meniscus lesions (Barret criteria) and on revision surgery, if any, in terms of the aspect and extent of the iterative lesion. The severity of any sensory disorder was assessed by questionnaire. The intraoperative complications rate was 1.5% (2 saphenous vein punctures). At a mean 31months (range, 28-35months), there was no loss to follow-up. Twelve patients (9%) showed symptomatic recurrence of the medial meniscus lesion, requiring 10 repeat surgeries. In 6 cases (4.5%), the iterative lesion involved a smaller, more central part of the meniscus anterior to the sutures, of "postage-stamp" effect, possibly implicating the suture hook and/or non-absorbable sutures. There were no cases of infection or fistula. Postoperative hematoma occurred in 7% of patients. In total, 1.8% reported dysesthesia areas equal to or greater than the size of a credit card (45cm 2 ). Some retears, or "partial failures", may implicate a new lesion caused by the suture hook and possibly prolonged by non-resorbable sutures. Hematoma and sensory disorder rates were comparable to those reported in isolated ACL repair without posteromedial portal. The present results show that posteromedial arthroscopic hook suture in posterior medial meniscus tear provides good healing rates without increased morbidity due to the supplementary portal. IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Massoud, Walid; Thanigasalam, Ruban; El Hajj, Albert; Girard, Frederic; Théveniaud, Pierre Etienne; Chatellier, Gilles; Baumert, Hervé
2013-07-01
To evaluate the use of a single needle driver with the V-Loc (Covidien, Dublin, Ireland) running suture and compare this with the use of 2 needle drivers with polyglactin interrupted sutures (IS) in dividing the dorsal venous complex (DVC) and forming the urethrovesical anastomosis (UVA) during robot-assisted radical prostatectomy (RARP). A prospective cohort study was performed to compare V-Loc (n = 40) with polyglactin (n = 40) sutures. Division of the dorsal venous complex and formation of the UVA during robot-assisted radical prostatectomy using V-Loc or polyglactin sutures were studied. Preoperative, intraoperative, and postoperative parameters were measured. V-Loc sutures were associated with a statistically significant reduction in mean dorsal vein suture time (3.15 minutes V-Loc vs 3.75 minutes IS, P = .02) and UVA anastomosis time (8.5 minutes V-Loc vs 11.5 minutes IS, P = .001). No significant difference was noted between operative time (121 minutes V-Loc vs 130 minutes IS, P = .199), delayed healing rates (5% V-Loc vs 7.5% IS, P = .238), continence rate at 12 months (97.5% V-Loc vs 95% IS, P = .368), and urethral stenosis rates (2.5% V-Loc vs 2.5% IS, P = .347) in both groups. The use of a V-Loc running suture with a single needle driver is a feasible, reproducible, and economic technique with no significant difference in continence rates and urethral stenosis rates, compared with the use of a traditional interrupted suture. Copyright © 2013 Elsevier Inc. All rights reserved.
Hanna, Amgad; Thompson, Daniel L; Hellenbrand, Daniel J; Lee, Jae-Sung; Madura, Casey J; Wesley, Meredith G; Dillon, Natalie J; Sharma, Tapan; Enright, Connor J; Murphy, William L
2016-07-01
Because of the dynamics of spinal cord injury (SCI), the optimal treatment will almost certainly be a combination approach to control the environment and promote axonal growth. This study uses peripheral nerve grafts (PNGs) as scaffolds for axonal growth while delivering neurotrophin-3 (NT-3) via calcium phosphate (CaP) coatings on surgical sutures. CaP coating was grown on sutures, and NT-3 binding and release were characterized in vitro. Then, the NT-3-loaded sutures were tested in a complete SCI model. Rats were analyzed for functional improvement and axonal growth into the grafts. The CaP-coated sutures exhibited a burst release of NT-3, followed by a sustained release for at least 20 days. Functionally, the rats with PNGs + NT-3-loaded sutures and the rats treated with PNGs scored significantly higher than controls on day 56 postoperatively. However, functional scores in rats treated with PNGs + NT-3-loaded suture were not significantly different from those of rats treated with PNGs alone. Cholera toxin subunit B (CTB) labeling rostral to the graft was not observed in any controls, but CTB labeling rostral to the graft was observed in almost all rats that had had a PNG. Neurofilament labeling on transverse sections of the graft revealed that the rats treated with the NT-3-loaded sutures had significantly more axons per graft than rats treated with an NT-3 injection and rats without NT-3. These data demonstrate that PNGs serve as scaffolds for axonal growth after SCI and that CaP-coated sutures can efficiently release NT-3 to increase axonal regeneration. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Li, Guang-Tai; Li, Xiao-Fan; Wu, Baoping; Li, Guangrui
2016-04-01
To assess the efficacy and safety of longitudinal parallel compression suture to control heavy postpartum hemorrhage (PPH) in patients with placenta previa/accreta. Fifteen women received a longitudinal parallel compression suture to stop life-threatening PPH due to placenta previa with or without accreta during cesarean section. The suture apposed the anterior and posterior walls of the lower uterine segment together using an absorbable thread A 70-mm round needle with a Number-1 absorbable thread was used. The point of needle entry was 1 cm above the upper margin of the cervix and 1 cm from the right lateral border of the lower segment of the anterior wall. The suture was threaded through the uterine cavity to the serosa of the posterior wall. Then, it was directed upward and threaded from the posterior to the anterior wall at ∼1-2 cm above the upper boundary of the lower uterine segment and 3-cm medial to the right margin of the uterus. Both ends of the suture were tied on the anterior aspect of uterus. The left side was sutured in the same way. The success rate of the procedure was 86.7% (13/15). Two of 15 cases were concurrently administered gauze packing and achieved satisfactory hemostasis. All patients resumed a normal menstrual flow, and no postoperative anatomical or physiological abnormalities related to the suture were observed. Three women achieved further pregnancies after the procedure. Longitudinal parallel compression suture is a safe, easy, effective, practical, and conservative surgical technique to stop intractable PPH from the lower uterine segment, particularly in women who have a cesarean scar and placenta previa/accreta. Copyright © 2016. Published by Elsevier B.V.
Editorial Commentary: All-Suture Anchors, Foam Blocks, and Biomechanical Testing.
Brand, Jefferson C
2017-06-01
Barber's biomechanical work is well known to Arthroscopy's readers as thorough, comprehensive, and inclusive of new designs as they become available. In "All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode," the latest iteration, Barber and Herbert test all-suture anchors in both porcine femurs and biphasic foam. While we await in vivo clinical trials that compare all-suture anchors to currently used anchors, Barber and Herbert have provided data to inform anchor choice, and using their biomechanical data at time zero from all-suture anchor trials in an animal model, we can determine the anchors' feasibility for human clinical investigations. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Medial Meniscus Posterior Root Repair Using a Transtibial Technique.
Woodmass, Jarret M; Mohan, Rohith; Stuart, Michael J; Krych, Aaron J
2017-06-01
The meniscal roots are critical in maintaining the normal shock absorbing function of the meniscus. If a meniscal root tear is left untreated, meniscal extrusion can occur rendering the meniscus nonfunctional resulting in degenerative arthritis. Two main repair techniques are described: (1) suture anchors (direct fixation) and (2) sutures pulled through a tibial tunnel (indirect fixation). Meniscal root repair using a suture anchor technique is technically challenging requiring a posterior portal and a curved suture passing device that can be difficult to manipulate within the knee. We present a technique for posterior medial meniscus root repair using 3 sutures (1 leader, 2 cinch), standard arthroscopy portals, and transtibial fixation. Overall, this technique simplifies a challenging procedure and allows for familiarity and efficiency.
Kudva, Adarsh; Kamath, Abhay; Cariappa, K M; Gadicherla, Srikanth; Dhara, B Vasantha
2017-12-01
An ectropion is a complication that can arise from reconstruction in the infraorbital region. Often, this complication occurs despite proper positioning of the lower lid at the time of closure. Various transcutaneous approaches to orbit skeleton have investigated in view of complication arising from them. A subtarsal approach with a postoperative Frost suture gives an advantage to reduce the occurrence of ectropion especially after treatment of orbital floor fractures. This case describes a method of subcuticular suturing technique for subtarsal incision of lower lid which can be used to support the lid during healing period, thus decreasing the rate of ectropion. The technique described here is an alterative method for frost suturing with certain advantages.
[Rehabilitation after anterior cruciate ligament suturing].
Andrtová, M; Chlupatá, I
1994-01-01
The authors discuss problems of rehabilitation after suture of the anterior cruciate ligament where frequently errors are committed and where inadequate rehabilitation may cause damage to the patient. Different periods of rehabilitation after LCA sutures are discussed and suitable methods of exercise for different periods are recommended.
Muresan, Claude; Lee, Tommy H; Seagull, Jacob; Park, Adrian E
2010-10-01
To help optimize the use of limited resources in trainee education, we developed a prospective randomized trial to determine the most effective means of teaching laparoscopic suturing to novices. Forty-one medical students received rudimentary instruction in intracorporeal suturing, then were pretested on a pig enterotomy model. They then were posttested after completion of 1 of 4 training arms: laparoscopic suturing, laparoscopic drills, open suturing, and virtual reality (VR) drills. Tests were scored for speed, accuracy, knot quality, and mental workload (National Aeronautics and Space Administration [NASA] Task Load Index). Paired t tests were used. Task time was improved in all groups except the VR group. Knot quality improved only in the open or laparoscopic suturing groups. Mental workload improved only for those practicing on a physical laparoscopic trainer. For novice trainees, the efficacy of VR training is questionable. In contrast, the other training methods had benefits in terms of time, quality, and perceived workload. Copyright © 2010 Elsevier Inc. All rights reserved.
Assessment of Intracorporeal Suturing in Single-Port Surgery Using an Experimental Suturing Model.
Ishiyama, Yasuhiro; Inaki, Noriyuki; Bando, Hiroyuki; Yamada, Tetsuji
2017-04-01
The aim of this study is to assess the difficulty of intracorporeal suturing in single-port surgery, using experimental suturing model in dry box. Subjects were divided for three groups: seven experienced laparoscopic surgeons, seven surgical residents, and seven interns. An experimental suturing model is developed, and working angle was set from 0° to 90°. The completion rate in 0° was significantly lower than that in the other angles. Completion rate of group A was higher than that of the other groups. Precision of task in group A was significantly higher than that of group B and group C in 0° and 60°. Stress score in 0° were significantly higher than that in the other angles. Our study demonstrated that intracorporeal suturing in single-port surgery seems to be more difficult than conventional laparoscopic surgery. Our data should be taken the institution under consideration for introduction of single-port surgery.
Ozaki, Mine; Takushima, Akihiko; Momosawa, Akira; Kurita, Masakazu; Harii, Kiyonori
2008-07-01
For a treatment of facial paralysis, suture suspension of soft tissue is considered effective due to its less invasiveness and relatively simple technique, with minimal bruising and rapid recovery. However, suture suspension effect may not last for a long period of time. We obtained good outcome with temporary static suture suspension in 5 cases of severe facial paralysis in the intervening period between the onset of paralysis and expected spontaneous recovery. We used the S-S Cable Suture (Medical U&A, Tokyo, Japan), which was based on the modification of previously established method using the Gore-Tex cable suture originally reported by Sasaki et al in 2002. Because of the ease of technique and relatively strong lifting capability of the malar pad, we recommend it as a useful procedure for a patient suffering acute facial paralysis with possible spontaneous recovery for an improved quality of life by the quick elimination of facial distortion.
Coexistence of Wormian Bones With Metopism, and Vice Versa, in Adult Skulls.
Cirpan, Sibel; Aksu, Funda; Mas, Nuket; Magden, Abdurrahman Orhan
2016-03-01
The aim of the study is to investigate coexistence of Wormian bones with metopism, and vice versa, in adult skulls. A total of 160 dry adult human skulls of unknown sex and ages were randomly selected from the Gross Anatomy Laboratory of Medical School of Dokuz Eylul University. The skulls were examined for presence of metopism, Wormian bones (WB), and coexistence of WBs with metopism and vice versa. Topographic distribution of the WBs was macroscopically evaluated within the skulls including metopism. The photographs were being taken with Canon 400B (55 mm objective). The frequency of metopism and WBs in 160 skulls is 7.50% (12/160) and 59.3% (95/160), respectively, P < 0.05 (). The incidence of coexistence of WBs with metopism was found as 11 of 12 skulls (91.66%), whereas the incidence of coexistence of metopism with WBs was found as 11 of 95 skulls (11.58%), P < 0.05 (). There were totally 23 sutures including WBs in 11 skulls, which had metopism (). The number (%) of metopic skulls for each specific suture including WBs were found as: 11 lamdoid sutures in 7/11 (63.63%) skulls, 4 lambda in 4/11 (36.36%) skulls, 2 asterion in 2/11 (18.18%) skulls, 1 squamous in 1/11 (9.09%) skull, 2 sagittal in 2/11 (18.18%) skulls, and 3 parieromsatoid sutures in 2/11 (18.18%) skulls (). The distribution of these 23 WBs in sutures of 11 skulls including metopisms is determined as follows: 11/23 (47.82%) WBs at lambdoid sutures [5/23 (21.74%) at the right lambdoid sutures and 6/23 (26.08%) at the left lambdoid sutures, and 4 pair of 11 WBs bilaterally located]; 4 (17.39%) WBs at lambda; 2/23 (8.69%) WBs at asterion [1/23 (4.34%) at the right asterion and 1/23 (4.34%) at the left asterion of 2 diverse skulls]; 2/23 (8.69%) WBs at sagittal sutures; 1/23 (4.34%) WBs at the left squamous suture; 3/23 (13.04%) WBs at parietomastoid sutures [2/23 (8.69%) at the right parietomastoid sutures and 1/23 (4.34%) at the left parietomastoid suture and 1 pair of them bilaterally located; , ].(Figure is included in full-text article.)(Table is included in full-text article.)(Table is included in full-text article.) : There was a significant difference in rates between coexistence of WBs with metopism (11/12, 91.66%) and coexistence of metopism with WBs (11/95, 11.58%). The factors leading to metopism may also lead to WBs, whereas that the factors leading to WBs may not lead to metopism.
FGFR2c-mediated ERK-MAPK activity regulates coronal suture development
Pfaff, Miles J.; Xue, Ke; Li, Li; Horowitz, Mark C.; Steinbacher, Derek M.; Eswarakumar, Jacob V.P.
2017-01-01
Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor’s gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. PMID:27034231
Aqua splint suture technique in isolated zygomatic arch fractures.
Kim, Dong-Kyu; Kim, Seung Kyun; Lee, Jun Ho; Park, Chan Hum
2014-04-01
Various methods have been used to treat zygomatic arch fractures, but no optimal modality exists for reducing these fractures and supporting the depressed bone fragments without causing esthetic problems and discomfort for life. We developed a novel aqua splint and suture technique for stabilizing isolated zygomatic arch fractures. The objective of this study is to evaluate the effect of novel aqua splint and suture technique in isolated zygomatic arch fractures. Patients with isolated zygomatic arch fractures were treated by a single surgeon in a single center from January 2000 through December 2012. Classic Gillies approach without external fixation was performed from January 2000 to December 2003, while the novel technique has been performed since 2004. 67 consecutive patients were included (Classic method, n = 32 and Novel method, n = 35). An informed consent was obtained from all patients. The novel aqua splint and suture technique was performed by the following fashion: first, we evaluated intraoperatively the bony alignment by ultrasonography and then, reduced the depressed fracture surgically using the Gillies approach. Thereafter, to stabilize the fracture and obtain the smooth facial figure, we made an aqua splint that fit the facial contour and placed monofilament nonabsorbable sutures around the fractured zygomatic arch. The novel aqua splint and suture technique showed significantly correlated with better cosmetic and functional results. In conclusion, the aqua splint suture technique is very simple, quick, safe, and effective for stabilizing repositioned zygomatic arch fractures. The aqua splint suture technique can be a good alternative procedure in isolated zygomatic arch fractures.
NASA Astrophysics Data System (ADS)
Le, Hanh N. D.; Opferman, Justin; Decker, Ryan; Cheon, Gyeong W.; Kim, Peter C. W.; Kang, Jin U.; Krieger, Axel
2016-04-01
Anastomosis, the connection of two structures, is a critical procedure for reconstructive surgery with over 1 million cases/year for visceral indication alone. However, complication rates such as strictures and leakage affect up to 19% of cases for colorectal anastomoses and up to 30% for visceral transplantation anastomoses. Local ischemia plays a critical role in anastomotic complications, making blood perfusion an important indicator for tissue health and predictor for healing following anastomosis. In this work, we apply a real time multispectral imaging technique to monitor impact on tissue perfusion due to varying interrupted suture spacing and suture tensions. Multispectral tissue images at 470, 540, 560, 580, 670 and 760 nm are analyzed in conjunction with an empirical model based on diffuse reflectance process to quantify the hemoglobin oxygen saturation within the suture site. The investigated tissues for anastomoses include porcine small (jejunum and ileum) and large (transverse colon) intestines. Two experiments using interrupted suturing with suture spacing of 1, 2, and 3 mm and tension levels from 0 N to 2.5 N are conducted. Tissue perfusion at 5, 10, 20 and 30 min after suturing are recorded and compared with the initial normal state. The result indicates the contrast between healthy and ischemic tissue areas and assists the determination of suturing spacing and tension. Therefore, the assessment of tissue perfusion will permit the development and intra-surgical monitoring of an optimal suture protocol during anastomosis with less complications and improved functional outcome.
Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika
2013-01-01
Background: For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. Methods: A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. Results: The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Conclusions: Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting. PMID:23691259
Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika
2013-01-01
For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting.
FGFR2c-mediated ERK-MAPK activity regulates coronal suture development.
Pfaff, Miles J; Xue, Ke; Li, Li; Horowitz, Mark C; Steinbacher, Derek M; Eswarakumar, Jacob V P
2016-07-15
Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor's gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. Copyright © 2016 Elsevier Inc. All rights reserved.
Comparison of Fibrin Glue and Sutures for Conjunctival Wound Closure in Strabismus Surgery
Lee, Jae Hyung
2011-01-01
Purpose To evaluate and compare the efficacy and tolerance of fibrin glue and sutures for closing conjunctival wounds in strabismus surgery. Methods In a prospective trial, we performed strabismus surgery using limbal incisions. Conjunctival wounds were closed with fibrin glue in 20 eyes of 20 patients (fibrin group) and 8-0 polyglactin suture in 20 eyes of 20 patients (suture group). Postoperative pain, tearing, and inflammation were compared at 1 day, 1 week, 3 weeks, and 6 weeks after surgery. Conjunctival incision healing was also investigated. Results One day and one week post-operatively, pain and tearing scores were lower in the fibrin group (p = 0.000, respectively). Mean surgery time was significantly shorter in the fibrin (48 ± 5 minutes) than the suture group (63 ± 7 minutes) (p = 0.000). Inflammation was significantly more severe in the suture group until 3 weeks postoperative (p = 0.000, respectively), but conjunctival healing did not differ between the groups. Hyperemia appeared more prominent in the fibrin group 3 and 6 weeks after surgery (p = 0.087 and 0.000, respectively). Two eyes in the fibrin group showed conjunctival gaps of more than 2 mm, which closed spontaneously by three weeks after surgery. No allergic reactions or infections developed. Conclusions Fibrin glue proved to be as effective as sutures in closing conjunctival wounds. It provides more comfortable early postoperative courses and might be considered as an alternative to sutures in strabismus surgery. PMID:21655043
21 CFR 882.4650 - Neurosurgical suture needle.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurosurgical suture needle. 882.4650 Section 882.4650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle...
21 CFR 882.4650 - Neurosurgical suture needle.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical suture needle. 882.4650 Section 882.4650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
Fournié, A; Madzou, S; Sentilhes, L; Descamps, P
2008-12-01
Two cases of evisceration after caesarean sections performed according the Misgav Ladach General Hospital procedure (Stark's procedure) are reported. In these cases, omentum was sutured between the edges of fascia recti, creating a weakness of the abdominal sheath. These cases claim about a strict procedure for fascia suture. Also, these cases question about the parietal peritoneal closure and the drawing of rectus muscles, which are vertical breaks; so, these sutures close transversal incision of the abdominal wall with cross sutures, which are very secure.
Grover, Davinder S; Fellman, Ronald L
2016-06-01
To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.
Lenz, Christopher G; Wieser, Karl; Lajtai, Georg; Meyer, Dominik C
2015-11-17
To compare instruments designed for arthroscopic suture handling during arthroscopic rotator cuff repair, to assess the force needed to penetrate the tendon, and to evaluate the residual defect size. Twenty-one instruments were each tested ten times on thawed sheep infraspinatus tendons. The force needed to pierce the tendon with each instrument was measured using a custom setup. Bone wax plates were used to make the perforation marks visible and to quantify the lesions each instrument created. The force to pierce a tendon had a range of 5.6-18.5 N/mm. Within the group of suture retrievers, the angled instruments required in average 85 % higher forces than straight instruments. The lesion area had a range of 2-7 mm(2). Suture retrievers produced significantly larger lesion sizes compared with suture shuttles. For the identical task of passing a suture through a tendon, differences exist regarding the ease of tendon penetration and potential damage to the tendon for different tools. The design, function, and resulting lesion size may be relevant and important for surgical handling and to avoid excess structural damage to the tendon. These results suggest that choosing the most appropriate tools for arthroscopic suture stitching influences the ease of handling and final integrity of the tissue.
Abbi, Gaurav; Espinoza, Luis; Odell, Timothy; Mahar, Andrew; Pedowitz, Robert
2006-01-01
To compare a standard suture material with a newer material using multiple arthroscopic knot configurations and to evaluate the biomechanical performance of a new sliding-locking knot compared with 4 surgical standards. Controlled laboratory study. Five knots were evaluated (Weston, Tennessee, Duncan, SMC, and the new San Diego knot) using 2 suture materials, No. 2 Ethibond (Ethicon, Somerville, NJ) or No. 2 Fiberwire (Arthrex, Naples, FL). Eight samples were tested for each knot-suture configuration. Samples were pretensioned to 10 N and then loaded from 10 to 45 N for 1,000 cycles. Intact knots were loaded to failure. Fiberwire had significantly higher load-to-failure (276 +/- 24 N) compared with Ethibond (111 +/- 13 N) (P < .001), although there was no significant difference as a function of knot configuration. Of the 40 Fiberwire knots, 3 failed by early slippage during cyclic loading and 8 slipped at very low tension during load-to-failure. None of the Ethibond knots and none of the San Diego knots failed by early slippage. Surface characteristics and suture construction affect the tendency for knot slippage. Surgeons should understand the impact of handling characteristics, frictional properties, and ultimate failure load when selecting suture materials and knots for arthroscopic repair.
Sarigul Guduk, Sukran; Karaca, Nezih
2018-04-01
Thread lifting is a minimally invasive procedure for lifting and repositioning tissues. Few articles with absorbable sutures exist in the literature. Furthermore there is no study focusing on complications of absorbable sutures. To describe complications of thread lifting using a totally absorbable suture composed of poly-L-lactic acid affixed with poly lactide/glycolide cones. Data regarding complications were analyzed retrospectively for 148 patients underwent thread lifting between June 2014 and February 2017. A total of 321 pairs of sutures used in the 148 patients studied. Overall 40 (27%) patients had complications regarded as minimal or moderate without permanent sequela. The most common complication was skin dimpling and irregularity (n = 17, 11.4%) followed by ecchymosis (n = 12, 8.1%), suture extrusion (n = 4, 2.7%), and pain (n = 4, 2.7%) Except one patient, dimpling, and irregularity resolved in all patients after 3-7 days spontaneously. Suture migration was observed in 2 (1.35%) patients. Hematoma and infection were seen in 2 patients one for each. The procedure using sutures made of absorbable poly-L-lactic acid and poly lactide/glycolide is a relatively safe procedure without major complications. © 2018 Wiley Periodicals, Inc.
Marr, Brendan; Yenumula, Panduranga
2012-01-01
Complications after laparoscopic Roux-en-Y gastric bypass surgery may be related to the type of surgical technique employed. One technique, the placement of a Roux limb stabilization suture, presumably prevents kink at the gastrojejunal anastomosis. However, it can have an adverse effect and we studied a series of cases presenting with intestinal obstruction secondary to this stitch. A retrospective review of a prospectively collected database of laparoscopic Roux-en-Y gastric bypass cases who had reoperations for Roux limb volvulus was performed at a single bariatric center by a single surgeon. Out of 199 patients who underwent laparoscopic Roux en Y gastric bypass with placement of Roux limb stabilization suture, 4 patients (2.01%) presented with Roux limb volvulus postoperatively. BMI was 45.35 ± 2.95. The postoperative time to presentation was 11 ± 10.6 months. All four patients required surgical exploration to reduce the volvulus. In all cases, the Roux limb volvulus was directly attributable to the presence of the stabilization suture. In subsequent 250 cases where this suture was eliminated, there was no volvulus of Roux limb seen. The use of a stabilization suture can result in volvulus of the Roux limb causing intestinal obstruction and this complication can be prevented by avoiding this suture.
Giusto, Gessica; Tramuta, Clara; Caramello, Vittorio; Comino, Francesco; Nebbia, Patrizia; Robino, Patrizia; Singer, Ellen; Grego, Elena; Gandini, Marco
2017-01-01
The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN ( P = 0.019). The OD of subgroup FG was lower than that of subgroup FN ( P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control ( P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern.
Murashita, Takashi; Okada, Yukikatsu; Kanemitsu, Hideo; Fukunaga, Naoto; Konishi, Yasunobu; Nakamura, Ken; Koyama, Tadaaki
2014-01-01
We investigated the long-term outcomes of suture/ring tricuspid valve annuloplasty for functional tricuspid regurgitation associated with degenerative mitral regurgitation. We retrospectively reviewed patients who underwent flexible ring tricuspid valve annuloplasty (n = 120) or suture tricuspid valve annuloplasty (n = 42) for functional tricuspid regurgitation concomitant with surgery for degenerative mitral regurgitation (mean follow-up duration, 5.3 ± 5.1 years). The mean age of patients was 62.5 ± 13.1 years. Thirty-day mortality was zero in the suture group, and 0.8% in the ring group. Tricuspid regurgitation grade at discharge was lower in the ring group ( p = 0.002). No difference was observed between survival and freedom from major cardiac/cerebrovascular adverse events between the groups. However, freedom from ≥moderate tricuspid regurgitation was higher in the ring group (Log-rank p = 0.003). From univariate analysis, the risk factors for ≥moderate TR were suture annuloplasty and preoperative tricuspid regurgitation grade. No reoperation for recurrent tricuspid regurgitation occurred in either group because symptoms experienced by patients with recurrent tricuspid regurgitation were relatively insignificant. Concomitant tricuspid annuloplasty using flexible bands offered improved durability than suture annuloplasty for preventing postoperative tricuspid regurgitation progression.
Investigation of the best suture pattern to close a stuffed Christmas turkey.
Verwilghen, D; Busoni, V; van Galen, G; Wilke, M
Instructions on how to debone and stuff a turkey are available, but what is the best way to close it up? A randomised trial involving 15 turkeys was performed in order to evaluate skin disruption scores and cosmetic outcomes following the use of different suture patterns. Turkeys were deboned, stuffed and cooked according to guidelines of the US Department of Agriculture Food Safety and Inspection Services. After stuffing, they were randomly assigned to one of five closure groups: simple continuous Lembert; simple continuous Cushing; simple continuous Utrecht; simple continuous; or staples. Turkeys were cooked at 180 °C for two hours ensuring core temperature reached 75 °C. Suture line integrity was evaluated after removal of the sutures and the cosmetic aspect was graded. Before cooking, the Utrecht pattern and skin staples offered the best cosmetic result. After removal of the sutures, the skin remained intact only in the stapled group. All other suture patterns disrupted the skin after removal of the sutures, rendering the turkey less cosmetically appealing for serving. Closure of a stuffed turkey was best performed using skin staples to achieve the best cosmetic results. Using this technique you will be able to impress family and friends at a Christmas dinner, and finally show them your surgical skills.
Suture versus tack fixation of mesh in laparoscopic umbilical hernia repair.
Kitamura, Riley K; Choi, Jacqueline; Lynn, Elizabeth; Divino, Celia M
2013-01-01
Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation. Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction. Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups. There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.
Winkel, R; Kalbhenn, O; Hoffmann, R
2012-06-01
This retrospective examination compares the results of finger flexor tendon sutures with 2 strands and 4 strands. It was checked, whether and how 2 more strands influenced the rupture rate, the movement of the finger and the contentment of the patients. From 1996 to 2000 for the core suture of the flexor tendon of fingers we used 2 strands. 35 patients with 40 tendon sutures of 73 patients were examined. From 2001 to 2005 we used for the core suture 2 loop threads. 53 patients with 64 tendon sutures from a total of 111 patients were examined. At least 12 months had passed between operation and the examination. The rupture rate and the range of movement of each finger joint and the total mobility of the affected fingers were evaluated. Each case was compared to the uninjured opposite hand. The functional result was judged according to the score of Buck-Gramcko. The patient's contentment was recorded by the DASH (disability of arm, shoulder and hand) score. Effects of gender, age, accompanying injuries, zone of the injury and their influence on the results were analysed. The Buck-Gramcko score showed in the 2-strand group a distribution from summarised 70% "excellent" and "good" and 30% "fair" and "poor". In the 4-strand-group the relation was 93.7% "excellent" and "good", 6.3% "fair", one "poor". In the 2-strand group 2/40 (5%) of the tendon sutures ruptured, in the 4-strand group 1/64 (1.6%) ruptured. The average DASH value in the 2-strands-group was 16.6/100, in the 4-strands-group 18.1/100 when 0 is the best possible result and 100 the worst. The patient judgement in the 2-strand group was summarised to 70% for "excellent" and "good" and 30% "fair" and "poor". In the 4-strand group the patient's judgment was summarised in 75% "excellent" and "good" and in 25% "fair". The results of flexor tendon sutures with 4-strand core sutures have been superior to the results with 2-strand core suture according to range of motion of the fingers (P <0.005). © Georg Thieme Verlag KG Stuttgart · New York.
1991-08-01
mill 3 dp Chromic Anodizing plus Polyurethane Fuel Coating 2 ep Sulfuric Acid Anodizing 1 Alloys other than aluminums require independent evaluation...generators for recircula- aluminum . During manufactur- tion. After peening, the ing, the iron is removed anodic coating and paint were prior to the...Growth Retardation in Aluminum Alloys . . 310 Quality Nondestructive Evaluation, and the ". .. IP’ Process
Installation Restoration Program. Phase I. Records Search, Vance Air Force Base, Oklahoma.
1984-07-01
cadmium , and descaling solutions. The general trend in waste disposal over the years since VAFB first began operation has been from 3 largely unsegregated...generated at the jet engine shop and metal plating shops and consists of phosphoric acid, chromic acid, potassium permanganate, cadmium , and descaling...benzene, MIBK, carbon tetrachloride, MEK, methylene chloride, and acetone. The metal analytes should include cadmium , chromium, copper, iron, lead
REFRACTORY DIE FOR EXTRUDING URANIUM
Creutz, E.C.
1959-08-11
A die is presented for the extrusion of metals, said die being formed of a refractory complex oxide having the composition M/sub n/O/sub m/R/sub x/O/sub y/ where M is magnesium, zinc, manganese, or iron, R is aluminum, chromic chromium, ferric iron, or manganic manganese, and m, n, x, and y are whole numbers. Specific examples are spinel, magnesium aluminate, magnetite, magnesioferrite, chromite, and franklinite.
Development of composite tube protective coatings
NASA Technical Reports Server (NTRS)
Dursch, H.; Hendricks, C.
1986-01-01
Protective coatings for graphite/epoxy (Gr/Ep) tubular structures proposed for the Space Station are evaluated. The program was divided into four parts; System Definition, Coating Concept Selection and Evaluation, Scale-up and Assembly, and Reporting. System Definition involved defining the structural and environmental properties required of the Gr/Ep tubes. The prepreg and ply sequence selected was a P75S/934 (O2, + or - 20, O2)sub s layup which meets the various structural requirements of the Space Station. Coating Concept and Selection comprised the main emphasis of the effort. Concepts for protectively coating the Gr/Ep tubes included the use of metal foil and electroplating. The program results demonstrated that both phosphoric and chromic acid anodized Al foil provided adequate adhesion to the Gr/Ep tubes and stability of optical properties when subjected to atomic oxygen and thermal cycling representative of the LEO environment. SiO2/Al coatings sputtered onto Al foils also resulted in an excellent protective coating. The electroplated Ni possessed unacceptable adhesion loss to the Gr/Ep tubes during atomic oxygen testing. Scale-Up and Assembly involved fabricating and wrapping 8-ft-long by 2-in-diameter Gr/EP tubes with chromic acid anodized foil and delivering these tubes, along with representative Space Station erectable end fittings, to NASA LaRC.
Analysis of the interphase of a polyamide bonded to chromic acid anodized Ti-6AL-4V
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guinta, R.K.; Kander, R.G.
2000-01-06
Structural adhesive joints, when tested as made, typically fail cohesively through the centerline of the adhesive. However, in any study of adhesive joint durability, failure near the adhesive/substrate interface becomes an important consideration. In the current study, an interfacially debonding adhesive test, the notched coating adhesion (NCA) test, was applied to LaRC(trademark) PETI-5 adhesive bonded to chronic acid anodized (CAA) Ti-6Al-4V. Post-failure analysis of the interphase region included X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), field emission scanning electron microscopy (FE-SEM), and atomic force microscopy (AFM). Mechanical interlocking between an adhesive and a substrate occurs when the liquid adhesivemore » flows into interstices of the substrate, solidifies, and becomes locked in place. Mechanical interlocking is believed to significantly contribute to the adhesion of substrates that exhibit microroughness, such as metal surfaces treated with chromic acid anodization or sodium hydroxide anodization. Filbey and Wightman found that an epoxy penetrated the pores of CAA Ti-6Al-4V, one of the limited number of pore penetration studies that have been reported. In the current study, the penetration of PETI-5 into the pores of CAA Ti-6Al-4V is investigated through analysis of adhesive/substrate failure surfaces.« less
NASA Astrophysics Data System (ADS)
Robertson, Alastair H. F.; Collins, Alan S.
2002-02-01
The Shyok Suture Zone (Northern Suture) of North Pakistan is an important Cretaceous-Tertiary suture separating the Asian continent (Karakoram) from the Cretaceous Kohistan-Ladakh oceanic arc to the south. In previously published interpretations, the Shyok Suture Zone marks either the site of subduction of a wide Tethyan ocean, or represents an Early Cretaceous intra-continental marginal basin along the southern margin of Asia. To shed light on alternative hypotheses, a sedimentological, structural and igneous geochemical study was made of a well-exposed traverse in North Pakistan, in the Skardu area (Baltistan). To the south of the Shyok Suture Zone in this area is the Ladakh Arc and its Late Cretaceous, mainly volcanogenic, sedimentary cover (Burje-La Formation). The Shyok Suture Zone extends northwards (ca. 30 km) to the late Tertiary Main Karakoram Thrust that transported Asian, mainly high-grade metamorphic rocks southwards over the suture zone. The Shyok Suture Zone is dominated by four contrasting units separated by thrusts, as follows: (1). The lowermost, Askore amphibolite, is mainly amphibolite facies meta-basites and turbiditic meta-sediments interpreted as early marginal basin rift products, or trapped Tethyan oceanic crust, metamorphosed during later arc rifting. (2). The overlying Pakora Formation is a very thick (ca. 7 km in outcrop) succession of greenschist facies volcaniclastic sandstones, redeposited limestones and subordinate basaltic-andesitic extrusives and flow breccias of at least partly Early Cretaceous age. The Pakora Formation lacks terrigenous continental detritus and is interpreted as a proximal base-of-slope apron related to rifting of the oceanic Ladakh Arc; (3). The Tectonic Melange (<300 m thick) includes serpentinised ultramafic rocks, near mid-ocean ridge-type volcanics and recrystallised radiolarian cherts, interpreted as accreted oceanic crust. (4). The Bauma-Harel Group (structurally highest) is a thick succession (several km) of Ordovician and Carboniferous to Permian-Triassic, low-grade, mixed carbonate/siliciclastic sedimentary rocks that accumulated on the south-Asian continental margin. A structurally associated turbiditic slope/basinal succession records rifting of the Karakoram continent (part of Mega-Lhasa) from Gondwana. Red clastics of inferred fluvial origin ('molasse') unconformably overlie the Late Palaeozoic-Triassic succession and are also intersliced with other units in the suture zone. Reconnaissance further east (north of the Shyok River) indicates the presence of redeposited volcaniclastic sediments and thick acid tuffs, derived from nearby volcanic centres, presumed to lie within the Ladakh Arc. In addition, comparison with Lower Cretaceous clastic sediments (Maium Unit) within the Northern Suture Zone, west of the Nanga Parbat syntaxis (Hunza River) reveals notable differences, including the presence of terrigenous quartz-rich conglomerates, serpentinite debris-flow deposits and a contrasting structural history. The Shyok Suture Zone in the Skardu area is interpreted to preserve the remnants of a rifted oceanic back-arc basin and components of the Asian continental margin. In the west (Hunza River), a mixed volcanogenic and terrigenous succession (Maium Unit) is interpreted to record syn-deformational infilling of a remnant back-arc basin/foreland basin prior to suturing of the Kohistan Arc with Asia (75-90 Ma).
Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro
2015-12-01
The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.
Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard
2017-12-09
Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.
High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.
Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E
2016-02-01
To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair strength compared with high-tensile strength suture at time-zero simulated testing. Published by Elsevier Inc.
Stefanidis, Dimitrios; Wang, Fikre; Korndorffer, James R; Dunne, J Bruce; Scott, Daniel J
2010-02-01
Intracorporeal suturing is one of the most difficult laparoscopic tasks. The purpose of this study was to assess the impact of robotic assistance on novice suturing performance, safety, and workload in the operating room. Medical students (n = 34), without prior laparoscopic suturing experience, were enrolled in an Institutional Review Board-approved, randomized protocol. After viewing an instructional video, subjects were tested in intracorporeal suturing on two identical, live, porcine Nissen fundoplication models; they placed three gastro-gastric sutures using conventional laparoscopic instruments in one model and using robotic assistance (da Vinci) in the other, in random order. Each knot was objectively scored based on time, accuracy, and security. Injuries to surrounding structures were recorded. Workload was assessed using the validated National Aeronautics and Space Administration (NASA) task load index (TLX) questionnaire, which measures the subjects' self-reported performance, effort, frustration, and mental, physical, and temporal demands of the task. Analysis was by paired t-test; p < 0.05 was considered significant. Compared with laparoscopy, robotic assistance enabled subjects to suture faster (595 +/- 22 s versus 459 +/- 137 s, respectively; p < 0.001), achieve higher overall scores (0 +/- 1 versus 95 +/- 128, respectively; p < 0.001), and commit fewer errors per knot (1.15 +/- 1.35 versus 0.05 +/- 0.26, respectively; p < 0.001). Subjects' overall score did not improve between the first and third attempt for laparoscopic suturing (0 +/- 0 versus 0 +/- 0; p = NS) but improved significantly for robotic suturing (49 +/- 100 versus 141 +/- 152; p < 0.001). Moreover, subjects indicated on the NASA-TLX scale that the task was more difficult to perform with laparoscopic instruments compared with robotic assistance (99 +/- 15 versus 57 +/- 23; p < 0.001). Compared with standard laparoscopy, robotic assistance significantly improved intracorporeal suturing performance and safety of novices in the operating room while decreasing their workload. Moreover, the robot significantly shortened the learning curve of this difficult task. Further study is needed to assess the value of robotic assistance for experienced surgeons, and validated robotic training curricula need to be developed.
Park, Ji Soon; McGarry, Michelle H; Campbell, Sean T; Seo, Hyuk Jun; Lee, Yeon Soo; Kim, Sae Hoon; Lee, Thay Q; Oh, Joo Han
2015-09-01
Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. Controlled laboratory study. A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P < .05 for all). Regarding contact area, no significant differences were found between 90 and 120 N at all positions, although there were significant differences between 60 and 90 N. The construct failure test demonstrated no significant differences in any parameters according to various tensions (P > .05 for all). Increasing bridging suture tension to over 90 N did not improve contact area but did increase contact force and pressure. Bridging suture tension did not significantly affect ultimate failure loads. Considering the risks of overtensioning bridging sutures, it may be clinically more beneficial to keep bridging suture tension below 90 N. © 2015 The Author(s).
Brown, Christopher A; Hurwit, Daniel; Behn, Anthony; Hunt, Kenneth J
2014-02-01
Anatomic repair is indicated for patients who have recurrent lateral ankle instability despite nonoperative measures. There is no difference in repair stiffness, failure torque, or failure angle between specimens repaired with all-soft suture anchors versus the modified Broström-Gould technique with sutures only. Controlled laboratory study. In 10 matched pairs of human cadaveric ankles, the anterior talofibular ligament (ATFL) was incised from its origin on the fibula. After randomization, 1 ankle was repaired to its anatomic insertion using two 1.4-mm JuggerKnot all-soft suture anchors; the other ankle was repaired with a modified Broström-Gould technique using 2-0 FiberWire. All were augmented using the inferior extensor retinaculum. All ankles were mounted to the testing machine in 20° of plantar flexion and 15° of internal rotation and loaded to failure after the repair. Stiffness, failure torque, and failure angle were recorded and compared using a paired Student t test with a significance level set at P < .05. There was no significant difference in failure torque, failure angle, or stiffness. No anchors pulled out of bone. The primary mode of failure was pulling through the ATFL tissue. There was no statistical difference in strength or stiffness between a 1.4-mm all-soft suture anchor and a modified Broström-Gould repair with 2-0 FiberWire. The primary mode of failure was at the tissue level rather than knot failure or anchor pullout. The particular implant choice (suture only, tunnel, anchor) in repairing the lateral ligament complex may not be as important as the time to biological healing. The suture-only construct as described in the Broström-Gould repair was as strong as all-soft suture anchors, and the majority of the ankles failed at the tissue level. For those surgeons whose preference is to use anchor repair, this novel all-soft suture anchor may be an alternative to other larger anchors, as none failed by pullout.
Primary closure versus non-closure of dog bite wounds. a randomised controlled trial.
Paschos, Nikolaos K; Makris, Eleftherios A; Gantsos, Apostolos; Georgoulis, Anastasios D
2014-01-01
Dog bite wounds represent a major health problem. Despite their importance, their management and especially the role of primary closure remain controversial. In this randomised controlled trial, the outcome between primary suturing and non-closure was compared. 168 consecutive patients with dog bite injuries were included in this study. The wounds were allocated randomly in two treatment approaches: Group 1, consisting of eighty-two patients, had their wound sutured, whilst Group 2, consisting of eighty-six patients, did not have their wounds sutured. All wounds were cleansed using high-pressure irrigation and povidone iodine. All patients received the same type of antibiotic treatment. Our measured outcomes included presence of infection and cosmetic appearance. Cosmetic outcome was evaluated using the Vancouver Scar Scale (VSS). Wound and patient characteristics, such as time of management, wound location and size, and patient age, were recorded and analysed for their potential role in the resulting outcome. The overall infection rate was 8.3%. No difference in the infection rate between primary suturing and non-suturing group was detected in the present study. The cosmetic appearance of the sutured wounds was significantly better (mean score 1.74) compared to the wounds that were left open (mean score 3.05) (p=0.0001). The infection rate was comparable among all age groups. Wounds treated within 8h of injury demonstrated an infection rate of 4.5%, which is lower compared to the 22.2% rate observed in wounds treated later than 8h. The wounds located at the head and neck exhibited better results in both infection rate and cosmetic outcome. Additionally, wounds >3 cm negatively affected the cosmetic appearance of the outcome. Primary suturing of wounds caused by dog bites resulted in similar infection rate compared to non-suturing. However, primary suturing exhibited improved cosmetic appearance. Time of management appeared to be critical, as early treatment resulted in lower infection rate and improved cosmetic appearance regardless suturing or not. Furthermore, wounds located at the head and face demonstrated better results. Copyright © 2013 Elsevier Ltd. All rights reserved.
Bueno, Letícia Rossi; Binda, Marcia; Monego, Heleusa; Scherer, Roberta Luísa; Rolim, Karen Machado; Bottini, Alessandra Leal; Fregnani, José H T G; dos Reis, Ricardo
2015-06-01
Compare blood loss during cold knife conization of the cervix with and without lateral hemostatic sutures in the cervical branches of the uterine arteries. Randomized clinical trial. Hospital de Clínicas de Porto Alegre (HCPA). 102 patients that underwent cold knife conization. Women that underwent cold knife conization of the cervix were randomized to undergo the procedure with or without lateral hemostatic sutures. blood loss measured in grams. operative time and postoperative intervention. Only the participants were blinded to group assignment. From March 2009 to August 2012, patients were randomly assigned to one of the study groups. There were no differences in amount of blood loss between patients that underwent the procedure with and without sutures (p = 0.39). Operative time was shorter in the group without suture (p = 0.020). There were no differences in intervention due to bleeding (p = 0.20). Blood loss was greater among menstruating women than for menopausal women (p = 0.011). There were no differences in amount of blood lost between smoking and nonsmoking patients (p = 0.082). Lateral hemostatic sutures do not affect the amount of intraoperative bleeding or the number of postoperative interventions. Their use is not necessary because they result in longer operative time, have a higher cost due to the use of suture material and pose the risk of ureter lesion in case the sutures are not placed at a lower position in the cervix. ClinicalTrials. gov identifier: NCT02184975. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
Jiang, Huiyong; Hao, Xiuyan; Xin, Ying; Pan, Youzhen
2017-11-01
To compare the clinical outcomes of multipoint umbrella suture and single-purse suture with two-point traction after procedure for prolapse and hemorrhoids surgery (PPH) for the treatment of mixed hemorrhoids. Ninety patients were randomly divided into a PPH plus single-purse suture group (Group A) and a PPH plus multipoint umbrella suture (Group B). All operations were performed by an experienced surgeon. Operation time, width of the specimen, hemorrhoids retraction extent, postoperative pain, postoperative bleeding, and length of hospitalization were recorded and compared. Statistical analysis was conducted by t-test and χ2 test. There were no significant differences in sex, age, course of disease, and degree of prolapse of hemorrhoids between the two groups. The operative time in Group A was significantly shorter than that in Group B (P < 0.05). However, the incidence rates of submucosal hematoma and incomplete hemorrhoid core retraction were significantly lower in Group B (P < 0.05), whereas the width of the specimens in Group B was greater than that in Group A (P < 0.05). There were fewer redundant skin tags in Group B at three months follow-up. No significant difference in postoperative pain, postoperative bleeding, and time of hospital stay (P > 0.05 for all comparisons) was observed. The multipoint umbrella suture showed better clinical outcomes because of its targeted suture according to the extent of hemorrhoid prolapse. Copyright © 2017. Published by Elsevier Ltd.
Effects of In Utero Thyroxine Exposure on Murine Cranial Suture Growth
Black, Laurel; Bennfors, Grace; Parsons, Trish E.; Elsalanty, Mohammed E.; Yu, Jack C.; Weinberg, Seth M.; Cray, James J.
2016-01-01
Large scale surveillance studies, case studies, as well as cohort studies have identified the influence of thyroid hormones on calvarial growth and development. Surveillance data suggests maternal thyroid disorders (hyperthyroidism, hypothyroidism with pharmacological replacement, and Maternal Graves Disease) are linked to as much as a 2.5 fold increased risk for craniosynostosis. Craniosynostosis is the premature fusion of one or more calvarial growth sites (sutures) prior to the completion of brain expansion. Thyroid hormones maintain proper bone mineral densities by interacting with growth hormone and aiding in the regulation of insulin like growth factors (IGFs). Disruption of this hormonal control of bone physiology may lead to altered bone dynamics thereby increasing the risk for craniosynostosis. In order to elucidate the effect of exogenous thyroxine exposure on cranial suture growth and morphology, wild type C57BL6 mouse litters were exposed to thyroxine in utero (control = no treatment; low ~167 ng per day; high ~667 ng per day). Thyroxine exposed mice demonstrated craniofacial dysmorphology (brachycranic). High dose exposed mice showed diminished area of the coronal and widening of the sagittal sutures indicative of premature fusion and compensatory growth. Presence of thyroid receptors was confirmed for the murine cranial suture and markers of proliferation and osteogenesis were increased in sutures from exposed mice. Increased Htra1 and Igf1 gene expression were found in sutures from high dose exposed individuals. Pathways related to the HTRA1/IGF axis, specifically Akt and Wnt, demonstrated evidence of increased activity. Overall our data suggest that maternal exogenous thyroxine exposure can drive calvarial growth alterations and altered suture morphology. PMID:27959899
Effects of In Utero Thyroxine Exposure on Murine Cranial Suture Growth.
Howie, R Nicole; Durham, Emily L; Black, Laurel; Bennfors, Grace; Parsons, Trish E; Elsalanty, Mohammed E; Yu, Jack C; Weinberg, Seth M; Cray, James J
2016-01-01
Large scale surveillance studies, case studies, as well as cohort studies have identified the influence of thyroid hormones on calvarial growth and development. Surveillance data suggests maternal thyroid disorders (hyperthyroidism, hypothyroidism with pharmacological replacement, and Maternal Graves Disease) are linked to as much as a 2.5 fold increased risk for craniosynostosis. Craniosynostosis is the premature fusion of one or more calvarial growth sites (sutures) prior to the completion of brain expansion. Thyroid hormones maintain proper bone mineral densities by interacting with growth hormone and aiding in the regulation of insulin like growth factors (IGFs). Disruption of this hormonal control of bone physiology may lead to altered bone dynamics thereby increasing the risk for craniosynostosis. In order to elucidate the effect of exogenous thyroxine exposure on cranial suture growth and morphology, wild type C57BL6 mouse litters were exposed to thyroxine in utero (control = no treatment; low ~167 ng per day; high ~667 ng per day). Thyroxine exposed mice demonstrated craniofacial dysmorphology (brachycranic). High dose exposed mice showed diminished area of the coronal and widening of the sagittal sutures indicative of premature fusion and compensatory growth. Presence of thyroid receptors was confirmed for the murine cranial suture and markers of proliferation and osteogenesis were increased in sutures from exposed mice. Increased Htra1 and Igf1 gene expression were found in sutures from high dose exposed individuals. Pathways related to the HTRA1/IGF axis, specifically Akt and Wnt, demonstrated evidence of increased activity. Overall our data suggest that maternal exogenous thyroxine exposure can drive calvarial growth alterations and altered suture morphology.
Zhang, Peng; Chen, TianWu; Chen, ShiYi
2016-01-01
Purpose. To compare the biomechanical properties of 3 suture-bridge techniques for rotator cuff repair. Methods. Twelve pair-matched fresh-frozen shoulder specimens were randomized to 3 groups of different repair types: the medially Knotted Suture Bridge (KSB), the medially Untied Suture Bridge (USB), and the Modified Suture Bridge (MSB). Cyclic loading and load-to-failure test were performed. Parameters of elongation, stiffness, load at failure, and mode of failure were recorded. Results. The MSB technique had the significantly greatest load to failure (515.6 ± 78.0 N, P = 0.04 for KSB group; P < 0.001 for USB group), stiffness (58.0 ± 10.7 N/mm, P = 0.005 for KSB group; P < 0.001 for USB group), and lowest elongation (1.49 ± 0.39 mm, P = 0.009 for KSB group; P = 0.001 for USB group) among 3 groups. The KSB repair had significantly higher ultimate load (443.5 ± 65.0 N) than USB repair (363.5 ± 52.3 N, P = 0.024). However, there was no statistical difference in stiffness and elongation between KSB and USB technique (P = 0.396 for stiffness and P = 0.242 for elongation, resp.). The failure mode for all specimens was suture pulling through the cuff tendon. Conclusions. Our modified suture bridge technique (MSB) may provide enhanced biomechanical properties when compared with medially knotted or knotless repair. Clinical Relevance. Our modified technique may represent a promising alternative in arthroscopic rotator cuff repair. PMID:27975065
Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric
2013-08-01
The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. Copyright 2013, SLACK Incorporated.
Total laparoscopic gastropexy using 1 simple continuous barbed suture line in 63 dogs.
Takacs, Joel D; Singh, Ameet; Case, J Brad; Mayhew, Philipp D; Giuffrida, Michelle A; Caceres, Ana V; Fox-Alvarez, W Alexander; Runge, Jeffrey J
2017-02-01
To describe the use and outcome of a single, simple continuous, barbed suture line for prophylactic, total laparoscopic gastropexy in dogs. Multi-center, retrospective case series. Sixty-three client-owned dogs. Medical records of dogs undergoing total laparoscopic gastropexy using a barbed suture at 4 academic veterinary hospitals from 2011-2015 were reviewed. Data collected included signalment, procedure time, procedure-associated complications, short-term complications, and long-term outcome. All procedures were performed under general anesthesia in dorsal to dorsal-left oblique recumbency. Laparoscopic ports were placed on ventral midline in 1 of 3 port configurations, and 5 mm laparoscopic needle drivers were used for intracorporeal sutured gastropexy with unidirectional barbed suture. The gastropexy was positioned just caudal to the 13th rib, 2-4 cm lateral to the rectus abdominis muscle. Sixty-three dogs underwent total laparoscopic gastropexy with a single, simple continuous, barbed suture line. Median gastropexy surgery time was 70 minutes (interquartile range [IQR] 60-90 minutes). One dog sustained splenic laceration from Veress needle penetration during initial abdominal insufflation. Short term (>24 hours to 6 months postoperative) complications included incisional seroma formation (n = 2) and suture reaction (n = 1). Long term (>6 months postoperative) complications included intermittent regurgitation and chronic diarrhea in 1 dog. Fifteen dogs had postoperative ultrasound and all had intact gastropexy sites. Total laparoscopic barbed gastropexy using a single, simple continuous, barbed suture line in dogs is safe and results in an intact gastropexy long term. © 2016 The American College of Veterinary Surgeons.
Mechanical Analysis of Cartilage Graft Reinforced with PDS Plate
Conderman, Christian; Kinzinger, Michael; Manuel, Cyrus; Protsenko, Dmitry; Wong, Brian J. F.
2014-01-01
Objectives/Hypothesis This study attempts to characterize the biomechanical properties of a PDS-cartilage composite graft for use in septorhinoplasty. Study Design Experimental Study. Methods This study used a PDS analog, porcine cartilage cut to 1 × 5 × 20 mm, and a mechanical testing platform to measure flexure of a composite graft. Samples were assessed in four groups based on variations in suture pattern and orientation. The platform measured the force required to deflect the sample 2 mm in single cantilever beam geometry before and after the polymer was affixed to the specimen. Elastic Moduli were calculated before and after application of the polydioxanone polymer. Results The average modulus of the cartilage alone was 17 ± 0.9 MPa. The modulus of the composite cartilage-polymer graft with 2 suture fixation was 21.2 ± 1.5 MPa. The 3-suture configuration produced an increase to 25.8 ± 2.23 MPa. The four-suture configuration produced 23.1 ± 3.19 MPa. The five-suture configuration produced 25.7 ± 2.6 MPa. The modulus of the analog alone was 170 ± 30 MPa. The modulus of the 0.5 mm PDS was 692 ± 37.4 MPa. The modulus of the 0.15 mm perforated PDS was 447 ± 34.8 MPa. Conclusions The study found that suturing a polymer plate to cartilage resulted in enhanced stiffness of the composite. Under the conditions of the study, there was no significant difference in elastic moduli between suture configurations, making the two-suture linear configuration optimal in the one-plane cantilever deflection model. PMID:22965809
Kuntz, Mel A.; Snee, Lawrence W.
2007-01-01
The papers in this volume describe petrologic, structural, and geochemical studies related to geographic areas adjacent to and including the Salmon River suture zone. We therefore start this volume by defining and giving a general description of that suture zone. The western margin of the North American continent was the setting for complex terrane accretion and large-scale terrane translation during Late Cretaceous and Eocene time. In western Idaho, the boundary that separates the Paleozoic-Mesozoic accreted oceanic, island-arc rocks on the west from Precambrian continental metamorphic and sedimentary rocks on the east is called the Salmon River suture zone (SRSZ). Readers will note that the term 'Salmon River suture zone' is used in the title of this volume and in the text of several of the papers and the term 'western Idaho suture zone' is used in several other papers in this volume. Both terms refer to the same geologic feature and reflect historical usage and custom; thus no attempt has been made by the editors to impose or demand a single term by the various authors of this volume. The suture zone is marked by strong lithologic and chemical differences. Rocks adjacent to the suture zone are characterized by high-grade metamorphism and much structural deformation. In addition, the zone was the locus of emplacement of plutons ranging in composition from tonalite to monzogranite during and after the final stages of accretion of the oceanic terrane to the North American continent. The contents of this paper consists of seven chapters.
A technique of snaring method for fitting a prosthetic valve into the annulus.
Nagasaka, Shigeo; Kawata, Tetsuji; Matsuta, Masahiro; Taniguchi, Shigeki
2005-01-01
Tourniquetting technique to fit a prosthetic valve (PV) into the annulus in valve replacement surgery has been previously reported. We modified the previously reported method and designed a simpler tying technique. We performed 11 aortic (AVR: including four cases for calcified aortic stenosis (AS) with a small annulus and one cases for infective endocarditis with intramuscular abscess cavity), eight mitral valve replacements (MVR), and one tricuspid valve replacement (TVR: for corrected transposition of the great arteries). A PV was implanted using 2-0 polyester mattress sutures with a pledget. Each of the two tourniquets held a suture at the bottom of the annulus and at the opposite position to fit a PV. The sutures between each snare were tied down from the bottom to the top. In MVR, after seating of a PV with two tourniquets, we could make sure that no native tissue of any preserved mitral apparatus disturbed PV leaflet motion. In calcific AS, a PV had a good fitting into the annulus because of tourniquets applied to unseated part during tying sutures. In AVR for infective endocarditis, mattress sutures supported by a Teflon pledget were placed to close the abscess cavity. After snaring on one of these sutures, we tied down the sutures, ensuring that they did not cut through the friable tissues. In TVR, we found that native leaflets interfered with PV motion after seating down the prosthesis and those leaflets were resected before tying down the sutures. Postoperative transesophageal echocardiography showed no paravalvular leakage in any patients and excellent PV functions.
Fibrin adhesive is better than sutures in pterygium surgery.
Ratnalingam, Vanitha; Eu, Andrew Lim Keat; Ng, Gim Leong; Taharin, Rohana; John, Elizabeth
2010-05-01
To evaluate the recurrence rate, surgical time, and postoperative pain between conjunctival autografting with sutures and with fibrin adhesive in pterygium surgery. A prospective, randomized, double-blind, clinical trial on the benefits of using fibrin adhesive in place of sutures in pterygium surgery. One hundred seventy-five eyes with primary pterygium were randomized to undergo pterygium surgery with conjunctival autograft transplantation using either fibrin adhesive or sutures. One hundred thirty-seven eyes of 113 patients that were operated on by a single surgeon (V.R.) completed the 1-year follow-up. Sixty-eight eyes were operated with fibrin adhesive and 69 eyes with sutures. Patients were followed up at 1 day, 1 week, 1 month, 6 months, and 1 year after surgery. Pterygium recurrence and postoperative pain was graded by an independent observer (A.L.) masked to the method of treatment. Surgical time was measured with a stopwatch. All patients were followed up for 1 year. There were 3 recurrences (4.41%) in the fibrin adhesive group and 11 recurrences (15.9%) in the suture group. The mean duration required to complete surgery in the fibrin adhesive group was 16.93 +/- 2.85 minutes, whereas that of the suture group was 29.84 +/- 5.65 minutes, which was statistically significant (P < 0.001). The immediate postoperative pain score and week 1 postoperative pain score were significantly lower in the fibrin adhesive group (P < 0.05). No major complications were observed in either group. The use of fibrin adhesive in primary pterygium surgery with conjunctival autografts reduces the recurrence rate, surgical time, and postoperative pain when compared with sutures.
Interactive Virtual Suturing Simulations: Enhancement of Student Learning in Veterinary Medicine
ERIC Educational Resources Information Center
Staton, Amy J.; Boyd, Christine B.
2013-01-01
This capstone addresses an instructional gap in the Morehead State University Veterinary Technology Program and in other similar programs around the globe. Students do not retain the knowledge needed to proficiently complete suture patterns nor do students receive sufficient instructional time during the year to master each suture pattern that is…
21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable poly(glycolide/l-lactide) surgical suture. 878.4493 Section 878.4493 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and...
21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance...
New suturing technique for robotic-assisted vaginal cuff closure during single-site hysterectomy.
Shin, So-Jin; Chung, Hyewon; Kwon, Sang-Hoon; Cha, Soon-Do; Cho, Chi-Heum
2017-06-01
To describe a simple and efficient technique for suturing the vaginal cuff in robotic-assisted single-site hysterectomy using barbed suture and a straight needle. Consecutive patients undergoing robotic-assisted single-site hysterectomy from February 2014 to August 2015 at Dong San Hospital, Keimyung University were included. Surgeons used two barbed sutures in a running fashion to close the vaginal cuff. A barbed suture was exclusively used with a straightened needle in upward direction from posterior vaginal cuff to anterior vaginal cuff which played a pivotal role for closure. A total of 100 patients underwent robotic-assisted single-site hysterectomy. The total operation time was 132.5 min and vaginal cuff closure time was 12.0 min. There were no postoperative complications; vaginal cuff dehiscence, vaginal cuff infection, and vaginal bleeding that require surgical intervention or admission. The use of barbed suture with straightened needle to close the vaginal cuff in robotic-assisted single-site hysterectomy is easy to perform and demonstrates safety and efficacy. This technique offers secure, fast, and effective incision closure.
Laparoscopic Suturing as a Barrier to Broader Adoption of Laparoscopic Surgery.
Lim, Sangtaeck; Ghosh, Sudip; Niklewski, Paul; Roy, Sanjoy
2017-01-01
Laparoscopic surgery is increasingly replacing the open procedure because of its many patient-related benefits that are well aligned with policies and programs that seek to optimize health system performance. However, widespread adoption of laparoscopic surgery has been slow, in part, because of the complexity of laparoscopic suturing. The objective of this study was to review the clinical and economic impacts of laparoscopic suturing in key procedures and to assess its role as a barrier to the broader adoption of laparoscopic surgery. A medical literature search of MEDLINE, EMBASE, and BIOSIS from January 2010 through June 2016 identified 47 relevant articles. Laparoscopic suturing and intracorporeal knot tying may result in extended surgical time, complications, and surgeon errors, while improving patient quality of life through improved cosmesis, diet toleration, and better bowel movements. Despite advancement in surgical techniques and the availability of newer surgical tools, the complexity of laparoscopic suturing continues to be a barrier to greater adoption of MIS. The results of the study underscore the need for development of proficiency in laparoscopic suturing, which may help improve patient outcomes and reduce healthcare costs.
Gleich, L L; Wang, Z; Pankratov, M M; Aretz, H T; Shapshay, S M
1995-05-01
Absorbable sutures have been advocated for tracheal anastomosis to reduce fibrosis and foreign body reaction leading to recurrent stenosis. Fibrin tissue adhesive (FTA) and diode laser welding with indocyanine green-dyed fibrinogen were evaluated in tracheal anastomosis to reduce the number of sutures and to improve healing. In vitro studies demonstrated strong anastomoses with a combination of laser welding and FTA with minimal tissue damage. In a controlled in vivo study, circumferential resections of canine tracheas were repaired with laser welding and FTA augmented with a few stay sutures. These anastomoses had less fibrosis and tissue damage than anastomoses in control animals repaired with sutures alone. This study supports investigation of laser welding and FTA in human beings for tracheal anastomosis and other procedures in which suturing may be difficult.
A Common Bile Duct Stone formed by Suture Material after Open Cholecystectomy
Kim, Kook-Hyun; Jang, Byung-Ik
2007-01-01
The use of non-absorbable suture materials for cystic duct ligation after cholecystectomy can expose patients to the risk of recurrent stone formation in the common bile duct (CBD). However, in Korea suture materials have rarely been found to act as a nidus for common bile duct calculus formation. Recently, we experienced a case in which suture material, that had migrated from a previous cholecystectomy site into the CBD, probably served as a nidus for common bile duct stone formation. The stone was confirmed by endoscopic retrograde cholangiopancreatography (ERCP) and removed successfully using a basket. The authors report a case of surgical suture migration and discuss its subsequent role as a stone forming nucleus within the CBD in a patient who underwent open cholecystectomy; and include a review of the literature. PMID:18309688
Chanda, Arnab; Unnikrishnan, Vinu; Flynn, Zachary; Lackey, Kim
2017-01-01
Skin injuries are the most common type of injuries occurring in day-to-day life. A skin injury usually manifests itself in the form of a wound or a cut. While a shallow wound may heal by itself within a short time, deep wounds require surgical interventions such as suturing for timely healing. To date, suturing practices are based on a surgeon's experience and may vary widely from one situation to another. Understanding the mechanics of wound closure and suturing of the skin is crucial to improve clinical suturing practices and also to plan automated robotic surgeries. In the literature, phenomenological two-dimensional computational skin models have been developed to study the mechanics of wound closure. Additionally, the effect of skin pre-stress (due to the natural tension of the skin) on wound closure mechanics has been studied. However, in most of these analyses, idealistic two-dimensional skin geometries, materials and loads have been assumed, which are far from reality, and would clearly generate inaccurate quantitative results. In this work, for the first time, a biofidelic human skin tissue phantom was developed using a two-part silicone material. A wound was created on the phantom material and sutures were placed to close the wound. Uniaxial mechanical tests were carried out on the phantom specimens to study the effect of varying wound size, quantity, suture and pre-stress on the mechanical behavior of human skin. Also, the average mechanical behavior of the human skin surrogate was characterized using hyperelastic material models, in the presence of a wound and sutures. To date, such a robust experimental study on the effect of injury and sutures on human skin mechanics has not been attempted. The results of this novel investigation will provide important guidelines for surgical planning and validation of results from computational models in the future.
Beimers, Lijkele; Lam, Patrick H; Murrell, George A C
2014-10-01
This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Bamberg, Christian; Dudenhausen, Joachim W; Bujak, Verena; Rodekamp, Elke; Brauer, Martin; Hinkson, Larry; Kalache, Karim; Henrich, Wolfgang
2018-06-01
We undertook a randomized clinical trial to examine the outcome of a single vs. a double layer uterine closure using ultrasound to assess uterine scar thickness. Participating women were allocated to one of three uterotomy suture techniques: continuous single layer unlocked suturing, continuous locked single layer suturing, or double layer suturing. Transvaginal ultrasound of uterine scar thickness was performed 6 weeks and 6 - 24 months after Cesarean delivery. Sonographers were blinded to the closure technique. An "intent-to-treat" and "as treated" ANOVA analysis included 435 patients (n = 149 single layer unlocked suturing, n = 157 single layer locked suturing, and n = 129 double layer suturing). 6 weeks postpartum, the median scar thickness did not differ among the three groups: 10.0 (8.5 - 12.3 mm) single layer unlocked vs. 10.1 (8.2 - 12.7 mm) single layer locked vs. 10.8 (8.1 - 12.8 mm) double layer; (p = 0.84). At the time of the second follow-up, the uterine scar was not significantly (p = 0.06) thicker if the uterus had been closed with a double layer closure 7.3 (5.7 - 9.1 mm), compared to single layer unlocked 6.4 (5.0 - 8.8 mm) or locked suturing techniques 6.8 (5.2 - 8.7 mm). Women who underwent primary or elective Cesarean delivery showed a significantly (p = 0.03, p = 0.02, "as treated") increased median scar thickness after double layer closure vs. single layer unlocked suture. A double layer closure of the hysterotomy is associated with a thicker myometrium scar only in primary or elective Cesarean delivery patients. © Georg Thieme Verlag KG Stuttgart · New York.
Fixation of the Achilles tendon insertion using suture button technology.
Fanter, Nathan J; Davis, Edward W; Baker, Champ L
2012-09-01
In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.
Lee, Sung Hyun; Kim, Jeong Woo; Kim, Tae Kyun; Kweon, Seok Hyun; Kang, Hong Je; Kim, Se Jin; Park, Jin Sung
2017-07-01
The purpose of this study was to compare functional outcomes and tendon integrity between the suture bridge and modified tension band techniques for arthroscopic rotator cuff repair. A consecutive series of 128 patients who underwent the modified tension band (MTB group; 69 patients) and suture bridge (SB group; 59 patients) techniques were enrolled. The pain visual analogue scale (VAS), Constant, and American Shoulder and Elbow Surgeons (ASES) scores were determined preoperatively and at the final follow-up. Rotator cuff hypotrophy was quantified by calculating the occupation ratio (OR). Rotator cuff integrity and the global fatty degeneration index were determined by using magnetic resonance imaging at 6 months postoperatively. The average VAS, Constant, and ASES scores improved significantly at the final follow-up in both groups (p < 0.05 for all scores). The retear rate of small-to-medium tears was similar in the modified tension band and suture bridge groups (7.0 vs. 6.8%, respectively; p = n.s.). The retear rate of large-to-massive tears was significantly lower in the suture bridge group than in the modified tension band group (33.3 vs. 70%; p = 0.035). Fatty infiltration (postoperative global fatty degeneration index, p = 0.022) and muscle hypotrophy (postoperative OR, p = 0.038) outcomes were significantly better with the suture bridge technique. The retear rate was lower with the suture bridge technique in the case of large-to-massive rotator cuff tears. Additionally, significant improvements in hypotrophy and fatty infiltration of the rotator cuff were obtained with the suture bridge technique, possibly resulting in better anatomical outcomes. The suture bridge technique was a more effective method for the repair of rotator cuff tears of all sizes as compared to the modified tension band technique. Retrospective Cohort Design, Treatment Study, level III.
Suture anchor repair of patellar tendon rupture after total knee arthroplasty.
Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L
2013-12-01
Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
The Effect of Capsulotomy and Capsular Repair on Hip Distraction: A Cadaveric Investigation.
Khair, M Michael; Grzybowski, Jeffrey S; Kuhns, Benjamin D; Wuerz, Thomas H; Shewman, Elizabeth; Nho, Shane J
2017-03-01
To quantify how increasing interportal capsulotomy size affects the force required to distract the hip and to biomechanically compare simple side-to-side suture repair to acetabular-based suture anchors as capsular repair techniques. Twelve fresh-frozen cadaveric hip specimens were dissected to the capsuloligamentous complex of the hip joint and fixed in a material testing system, such that a pure axial distraction of the iliofemoral ligament could be achieved. After each hip in was tested an intact state, sequential distraction was tested with 2, 4, 6, and 8 cm capsulotomies. Specimens were assigned randomly to be repaired with either 4 side-to-side suture repair (n = 6) or 2 double-loaded all-suture anchors (n = 6). The distraction force as well as the relative distraction force percentage normalized to the intact capsule were compared between suture repair and suture anchor repair groups. Increasing the size of the capsulotomy resulted in less force required to distract the hip to 6 mm. The force decreased as the capsulotomy was extended with statistical significance in distraction force seen between the intact state and the 4 cm (P = .003), 6 cm (P < .001), and 8 cm (P ≤ .001) capsulotomy but not for the intact state compared to the 2 cm capsulotomy (P = .28). Statistical significance in relative distraction force was seen for each of the capsulotomy conditions (P < .001 for all conditions compared with the intact state). The side-to-side suture repair construct (104.3% of intact force) required greater force to distraction to 6 mm compared with the suture anchor repair (87.1% of intact force) (P = .008). An interportal capsulotomy significantly affected the force required to distract the hip in a cadaveric model, with the larger the size of capsulotomy resulting in less force required to distract the hip. When we performed an interportal capsulotomy, the iliofemoral ligament strength was altered significantly but capsular repair with either side-to-side sutures or suture anchor-based repair was able to restore the capsular strength to a native intact hip. We found, however, that the side-to-side suture repair was better able to restore the distraction force compared with suture anchor repair. Capsular management during hip arthroscopy remains a debated topic, with multiple techniques involving both capsulotomy and capsular closure published in the literature. This study provides insight into capsular stability against axial stress under capsulotomy and capsular repair conditions. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Cranial Suture Closure in Domestic Dog Breeds and Its Relationships to Skull Morphology.
Geiger, Madeleine; Haussman, Sinah
2016-04-01
Bulldog-type brachycephalic domestic dog breeds are characterized by a relatively short and broad skull with a dorsally rotated rostrum (airorhynchy). Not much is known about the association between a bulldog-type skull conformation and peculiar patterns of suture and synchondrosis closure in domestic dogs. In this study, we aim to explore breed-specific patterns of cranial suture and synchondrosis closure in relation to the prebasial angle (proxy for airorhynchy and thus bulldog-type skull conformation) in domestic dogs. For this purpose, we coded closure of 18 sutures and synchondroses in 26 wolves, that is, the wild ancestor of all domestic dogs, and 134 domestic dogs comprising 11 breeds. Comparisons of the relative amount of closing and closed sutures and synchondroses (closure scores) in adult individuals showed that bulldog-type breeds have significantly higher closure scores than non-bulldog-type breeds and that domestic dogs have significantly higher closure scores than the wolf. We further found that the prebasial angle is significantly positively correlated with the amount of closure of the basispheno-presphenoid synchondrosis and sutures of the nose (premaxillo-nasal and maxillo-nasal) and the palate (premaxillo-maxillary and interpalatine). Our results show that there is a correlation between patterns of suture and synchondrosis closure and skull shape in domestic dogs, although the causal relationships remain elusive. © 2016 Wiley Periodicals, Inc.
Detecting the limits of bronchial closure methods in an animal model.
Tezel, C; Urek, S; Keles, M; Kiral, H; Koşar, A; Dudu, C; Arman, B
2006-04-01
Bronchopleural fistula is a serious complication of major lung resections that may lead to mortality. An experimental animal model was designed to find out the safest bronchial closure method by comparing leakage rates under pressure. The tracheobronchial trees of 50 freshly dead sheep were prepared for either manual closure or closure with a stapler. After left pneumonectomy, the specimens were divided into five groups (n = 10); 3/0 Premilene suture was used with two "u" sutures + interrupted sutures in Group I; in Group II, 3/0 Premilene sutures with continuous horizontal mattress + over-over continuous sutures were used. In Group III and IV the same techniques were used with 3/0 Vicryl. A stapler was used in Group V. Specimens were intubated with an endotracheal tube, connected to a sphygmomanometer, and subsequently positioned under water. The pressure level at which we detected air bubbles indicated the limits of the technique. The median leakage pressure resistance was significantly lower in Group III (135 mm Hg) ( P = 0.001). The best results were achieved by using the continuous horizontal mattress + over-over continuous suture technique. No statistical significance difference was found between the stapler group, Groups I, II, and IV in terms of median leakage pressures. This trial suggests that manual suture closure using an appropriate technique and monofilament materials is as safe as the stapler.
Giusto, Gessica; Tramuta, Clara; Caramello, Vittorio; Comino, Francesco; Nebbia, Patrizia; Robino, Patrizia; Singer, Ellen; Grego, Elena; Gandini, Marco
2017-01-01
The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN (P = 0.019). The OD of subgroup FG was lower than that of subgroup FN (P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control (P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern. PMID:28154467
Bacterial biofilms on implanted suture material are a cause of surgical site infection.
Kathju, Sandeep; Nistico, Laura; Tower, Irene; Lasko, Leslie-Ann; Stoodley, Paul
2014-10-01
Surgical site infection (SSI) has been estimated to occur in up to 5% of all procedures, accounting for up to 0.5% of all hospital costs. Bacterial biofilms residing on implanted foreign bodies have been implicated as contributing or causative factors in a wide variety of infectious scenarios, but little consideration has been given to the potential for implanted, submerged suture material to act as a host for biofilm and thus serve as a nidus of infection. We report a series of 15 patients who underwent open Roux-en-Y gastric bypass (with musculofascial closure with permanent, multifilament sutures) who developed longstanding and refractory SSIs in the abdominal wall. Explanted suture material at subsequent exploration was examined for biofilm with confocal laser-scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). All 15 patients at re-exploration were found to have gross evidence of a "slimy" matrix or dense reactive granulation tissue localized to the implanted sutures. Confocal laser-scanning microscopy revealed abundant biofilm present on all sutures examined; FISH was able to identify the presence of specific pathogens in the biofilm. Complete removal of the foreign bodies (and attendant biofilms) resulted in all cases in cure of the SSI. Bacterial biofilms on implanted suture material can manifest as persistent surgical site infections that require complete removal of the underlying foreign body substrata for resolution.
Does vascular stapling improve compliance of vascular anastomoses?
Stansby, G; Knez, P; Berwanger, C S; Nelson, K; Reichert, V; Schmitz-Rixen, T
2001-01-01
Elastic properties of vessel walls are altered by vascular anastomoses. Such alterations may lead to neointimal hyperplasia, which is a common cause of reocclusion following vascular surgery. The severity of paraanastomotic hypercompliant zones and anastomotic compliance drop depend on suturing material and on elastic properties of the anastomotic vessel segments. This study compares paraanastomotic hypercompliance and anastomotic compliance drop when using a new vascular closure system (VCS) and a conventional, continuous suture line in the preparation of end-to-end anastomoses. Compliance of artery-artery, vein-artery, and polytetrafluoroethylene-artery anastomoses was measured in an artificial circulation system at mean pressures of 60, 90, and 120 mm Hg, comparing conventional suturing and the VCS. When using the VCS for vein-artery anastomoses, significantly less postanastomotic hypercompliance was achieved at mean pressures of 60 mm Hg (14.2 +/-3.8% above remote postanastomotic area), compared to suture (55.1 +/-14.8%, p<0.05). At 90 mm Hg, respective values were 11.0 +/-2.3% for VCS and 54.7 +/-10.1% for suture, p<0.01. At 120 mm Hg, in polytetrafluoroethylene-artery anastomoses, the anastomotic compliance drop was significantly less when using the continuous suture line (93.9 +/-1.1% below remote postanastomotic compliance), compared to VCS (97.2 +/-0.2%, p<0.05). Compared to conventional suturing, use of the VCS reduced postanastomotic hypercompliance in vein-artery anastomoses.
[Establishment of endometriosis subcutaneous model in immunodeficient nude mice].
Ni, H J; Zhang, Z; Dai, Y D; Zhang, S Y
2016-09-06
Objective: To establish a model of endometriosis in immunodeficient nude mice and compare the outcome of the model construction between two different techniques. Methods: Eighteen nude mice were divided into 2 groups, with 9 mice in each group. All nude mice received a subcutaneous transplantation of endometrial fragments, followed by sutured the wounded skin (sutured group) or not (no-sutured group). Then the success rate of the model construction, inflammation of the wounds and the animal survival rate in the two groups were analyzed. Result: In no-sutured group, the survival rate of animal and the success rate of the model construction were 9/9 and 8/9 respectively, with 8/9 survival rate and 7/9 success rate in sutured group. No significant difference was found between the two groups. And no obvious inflammation was presented in the wounds for both groups. Conclusion: It is an effective method to establish animal model of endometriosis by subcutaneous transplantation in nude mice. After transplantation, it does not affect the outcome of the survival rate of the animal and the success rate of the model construction whether we suture the wounded skin. Considering the shorter operation time, we found it's a simpler and time saving method to establish endometriosis by subcutaneously transplanting endometrial fragments in nude mice with no skin-sutured. And this model is worth of promotion.
Hazratwala, Kaushik; Best, Alistair; Kopplin, Matthew; Giza, Eric; Sullivan, Martin
2005-03-01
The modified Broström ligament reconstruction using anchor sutures has been performed in adults with clinical success; however, the safety parameters for the use of suture anchors in adolescent lateral ankle ligament reconstruction have not been established. To perform a radiographic analysis comparing the depth of penetration of suture anchors in adult ankle ligament reconstruction with the average distance of the physis from the tip of the fibula in adolescents. Cross-sectional study, Level of evidence, 4. Forty postoperative ankle radiographs of adult patients who had a modified Broström procedure were compared with 40 normal adolescent ankle radiographs. In the adult group, the distance of the suture anchor penetration from the distal tip of the fibula was measured; in the adolescent group, the distance of the physis from the distal tip of the fibula was measured. The mean depth of the suture anchors was 17 mm (range, 14-21 mm) from the tip of the fibula in the adult group, and the mean distance of the growth plate was 23 mm (range, 18-29 mm) in the adolescent group. Eight radiographs from the adolescent group (20%) had a physis measurement of <22 mm on the anteroposterior or mortise view. Using careful preoperative planning and intraoperative technique, it is possible to safely perform lateral ankle ligament repair in the skeletally immature patient using suture anchors.
Robot-assisted bronchoplasty using continuous barbed sutures.
Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc
2018-01-01
We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.
Geology of the Payette National Forest and vicinity, west-central Idaho
Lund, Karen
2005-01-01
Before the Late Cretaceous, the eastern and western parts of the geologically complex Payette National Forest, as divided by the Salmon River suture, had fundamentally different geologic histories. The eastern part is underlain by Mesoproterozoic to Cambrian(?) rocks of the Laurentian (Precambrian North American) continent. Thick Mesopro-terozoic units, which are at least in part equivalent in age to the Belt Supergroup of northern Idaho and western Montana, underwent Mesoproterozoic metamorphic and deformational events, including intrusion of Mesoproterozoic plutons. Dur-ing the Neoproterozoic to early Paleozoic, the western edge of Laurentia was rifted. This event included magmatism and resulted in deposition of rift-related Neoproterozoic to Lower Cambrian(?) volcanic and sedimentary rocks above Mesopro-terozoic rocks. The western part of the forest is underlain by upper Paleozoic to lower Mesozoic island-arc volcanic and sedimentary rocks. These rocks comprise four recognized island-arc terranes that were amalgamated and intruded by intermediate-composition plutons, probably in the Late Juras-sic and Early Cretaceous, and then sutured to Laurentia along the Salmon River suture in the Late Cretaceous. The Salmon River suture formed as a right-lateral, transpressive fault. The metamorphic grade and structural complexity of the rocks increase toward the suture from both sides, and geochemical signatures in crosscutting plutonic rocks abruptly differ across the crustal boundary. Having been reactivated by younger structures, the Salmon River suture forms a north-trending topographic depression along Long Valley, through McCall, to the Goose Creek and French Creek drainages. During the last stages of metamorphism and deformation related to the suture event, voluminous plutons of the Idaho batholith were intruded east of the suture. An older plutonic series is intermediate in composition and preserved as elon-gated and deformed bodies near the suture and as parts of roof pendants to younger intrusions to the east. A younger magma series consists of undeformed, marginally peraluminous plu-tons that formed east of the suture after accretion. After suture-related compression, crustal extension resulted in voluminous volcanic and plutonic rocks of the Eocene Challis magmatic complex on the east side of the forest. Extension, from the Late Cretaceous to post-Miocene, uplifted the area of the Idaho batholith relative to the western part of the for-est and formed dominant highlands along the Snake River. Extensional basins also formed such that, in the Miocene, the Columbia River Basalt Group and related basaltic lavas flowed over most of the lower elevations on the western side of the forest and redirected erosional debris into north-trending, fault-controlled drainages and young sedimentary basins.
Ganpule, Arvind P; Deshmukh, Chaitanya S; Joshi, Tanmay
2018-01-01
The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a" key" instrument to accomplish this arduous task. The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder.
Law, Ryan; Prabhu, Anoop; Fujii-Lau, Larissa; Shannon, Carol; Singh, Siddharth
2018-02-01
Covered self-expandable metal stents (SEMS) are utilized for the management of benign and malignant esophageal conditions; however, covered SEMS are prone to migration. Endoscopic suture fixation may mitigate the migration risk of covered esophageal SEMS. Hence, we conducted a systematic review and meta-analysis to evaluate the effectiveness and safety of endoscopic suture fixation for covered esophageal SEMS. Following PRISMA guidelines, we performed a systematic review from 2011 to 2016 to identify studies (case control/case series) reporting the technical success and migration rate of covered esophageal SEMS following endoscopic suture fixation. We searched multiple electronic databases and conference proceedings. We calculated pooled rates (and 95% confidence intervals [CI]) of technical success and stent migration using a random effects model. We identified 14 studies (212 patients) describing covered esophageal SEMS placement with endoscopic suture fixation. When reported, SEMS indications included leak/fistula (n = 75), stricture (n = 65), perforation (n = 10), and achalasia (n = 4). The pooled technical success rate was 96.7% (95% CI 92.3-98.6), without heterogeneity (I 2 = 0%). We identified 29 SEMS migrations at rate of 15.9% (95% CI 11.4-21.6), without heterogeneity (I 2 = 0%). Publication bias was observed, and using the trim-and-fill method, a more conservative estimate for stent migration was 17.0%. Suture-related adverse events were estimated to occur in 3.7% (95% CI 1.6-8.2) of cases. Endoscopic suture fixation of covered esophageal SEMS appears to reduce stent migration when compared to published rates of non-anchored SEMS. However, SEMS migration still occurs in approximately 1 out of 6 cases despite excellent immediate technical success and low risk of suture-related adverse events.
Zwagerman, Nathan T; Geltzeiler, Mathew N; Wang, Eric W; Fernandez-Miranda, Juan C; Snyderman, Carl H; Gardner, Paul A
2018-05-30
We present a case of cerebrospinal fluid (CSF) leak after endoscopic endonasal resection of a large clival chordoma in an obese patient. The leak was at the lower reconstruction at the craniocervical junction and had failed repositioning. Using the V-Loc™ wound closure device (Covidien, New Haven, Connecticut) to suture the nasoseptal flap to the nasopharyngeal fascia, a water-tight seal was created and, along with a lumbar drain, the patient healed successfully.CSF leak after an endoscopic endonasal approach (EEA) to intradural pathologies remains one of the more common complications.1-4 Various closure techniques have been developed5-8 with success in mitigating this risk, but all have their limitations and rely on multiple layers including vascularized flaps like the nasoseptal flap.9-11 Endonasal suturing of graft materials offers the advantage of creating a water-tight seal. We present the use of the V-Loc™ wound closure device (Covidien) to successfully seal a postoperative CSF leak. The absorbable V-Loc™ wound closure device does not require the surgeon to tie knots, which is the most challenging step in a deep, 2-dimensional corridor. The suture is barbed and is anchored by threading the needle through a prefabricated loop at the end of the suture which locks in place. Each throw of the suture through tissue maintains the suture line as the barbs catch the tissue and prevent retraction. After successful closure, the needle can simply be cut off.The V-Loc™ wound closure device (Covidien) is a safe and effective adjunct to reconstruction after endoscopic endonasal skull base surgery as it provides an option for graft/flap suturing.A written release from the patient whose name or likeness is submitted as part of this Work is on file.
Ganpule, Arvind P.; Deshmukh, Chaitanya S.; Joshi, Tanmay
2018-01-01
Introduction: The challenges in laparoscopic suturing include need to expertise to suture. Laparoscopic needle holder is a ”key” instrument to accomplish this arduous task. Instrument: The objective of this new invention was to develop a laparoscopic needle holder which would be adapted to avoid any wobble (with a shaft diameter same as a 5mm port), ensure accurate and dexterous suturing not just in adult patients but pediatric patients alike (with a short shaft diameter) and finally ensure seamless throw of knots with a narrow tip configuration. Validation: We did an initial evaluation to evaluate the validity of the prototype needle holder and its impact on laparoscopic suturing skills by experienced laparoscopic surgeons and novice laparoscopic Surgeons. Both the groups of surgeons performed two tasks. The first task was to grasp the needle and position it in an angle deemed ideal for suturing. The second task was to pass suture through two fixed points and make a single square knot. At the end of the tasks each participant was asked to complete a 5- point Likert's scale questionnaire (8 items; 4 items of handling and 4 items of suturing) rating each needle holder. In expert group, the mean time to complete task 1 was shorter with prototype 3/5 laparoscopic needle holder (11.8 sec Vs 20.8 sec). The mean time to complete task 2 was also shorter with prototype 3/5 laparoscopic needle holder (103.2 sec Vs 153.2 sec). In novice group, mean time to complete both the task was shorter with prototype 3/5 laparoscopic needle holder. Conclusion: The expert laparoscopic surgeons as well as novice laparoscopic surgeons performed laparoscopic suturing faster and with more ease while using the prototype 3/5 laparoscopic needle holder. PMID:28782740
Zhao, Shuya; Wang, Xuxia; Li, Na; Chen, Yun; Su, Yuran; Zhang, Jun
2015-01-01
Background The aim of this experimental study was to investigate the effects of strontium ranelate on bone regeneration in the mid-palatal suture in response to rapid maxillary expansion (RME). Methods Thirty-six male 6-week-old Wistar rats were randomly divided into three groups, ie, an expansion only (EO) group, an expansion plus strontium ranelate (SE) group, and a control group. An orthodontic appliance was set between the right and left upper molars of rats with an initial expansive force of 0.98 N. Rats in the SE group were administered strontium ranelate (600 mg/kg body weight) and then euthanized in batches on days 4, 7, and 10. Morphological changes in the mid-palatal suture were investigated using micro-computed tomography and hematoxylin and eosin staining after RME. Bone morphogenetic protein-2 expression in the suture was also examined to evaluate bone formation in the mid-palatal suture. Image-Pro Plus software was then used to determine the mean optical density of the immunohistochemical images. Analysis of variance was used for statistical evaluation at the P<0.05 level. Results With expansive force, the mid-palatal suture was expanded, but there was no statistically significant difference (P>0.05) between the SE and EO groups. The bone volume of the suture decreased after RME, but was higher in the SE group than in the EO group on days 7 and 10. Further, expression of bone morphogenetic protein-2 in the SE group was higher than in the other two groups (P<0.05). Conclusion Strontium ranelate may hasten new bone formation in the expanded mid-palatal suture, which may be therapeutically beneficial in prevention of relapse and shortening the retention period after RME. PMID:26056433
Esquivel, Amanda O.; Duncan, Douglas D.; Dobrasevic, Nikola; Marsh, Stephanie M.; Lemos, Stephen E.
2015-01-01
Background: Rotator cuff tendinopathy is a frequent cause of shoulder pain that can lead to decreased strength and range of motion. Failures after using the single-row technique of rotator cuff repair have led to the development of the double-row technique, which is said to allow for more anatomical restoration of the footprint. Purpose: To compare 5 different types of suture patterns while maintaining equality in number of anchors. The hypothesis was that the Mason-Allen–crossed cruciform transosseous-equivalent technique is superior to other suture configurations while maintaining equality in suture limbs and anchors. Study Design: Controlled laboratory study. Methods: A total of 25 fresh-frozen cadaveric shoulders were randomized into 5 suture configuration groups: single-row repair with simple stitch technique; single-row repair with modified Mason-Allen technique; double-row Mason-Allen technique; double-row cross-bridge technique; and double-row suture bridge technique. Load and displacement were recorded at 100 Hz until failure. Stiffness and bone mineral density were also measured. Results: There was no significant difference in peak load at failure, stiffness, maximum displacement at failure, or mean bone mineral density among the 5 suture configuration groups (P < .05). Conclusion: According to study results, when choosing a repair technique, other factors such as number of sutures in the repair should be considered to judge the strength of the repair. Clinical Relevance: Previous in vitro studies have shown the double-row rotator cuff repair to be superior to the single-row repair; however, clinical research does not necessarily support this. This study found no difference when comparing 5 different repair methods, supporting research that suggests the number of sutures and not the pattern can affect biomechanical properties. PMID:26665053
Goschka, Andrew M; Hafer, Jason S; Reynolds, Kirk A; Aberle, Nicholas S; Baldini, Todd H; Hawkins, Monica J; McCarty, Eric C
2015-10-01
To further reduce the invasiveness of arthroscopic rotator cuff repair surgery the all-suture anchor has been developed. The all-suture anchor requires less bone removal and reduces the potential of loose body complications. The all-suture anchor must also have adequate biomechanical strength for the repair to heal. The hypothesis is there is no significant difference in the biomechanical performance of supraspinatus repairs using an all-suture anchor when compared to traditional solid-body suture anchors. Using nine shoulders per group, the supraspinatus tendon was dissected from the greater tuberosity. The four different double row repairs tested were (medial row/lateral row): A: ICONIX2/ICONIX2; B: ICONIX2/Stryker ReelX 3.9mm; C: ICONIX2/Stryker ReelX 4.5mm; D: Arthrex BioComposite CorkScrew FT 4.5mm/Arthrex BioComposite SwiveLock 4.75mm. The ICONIX2 was the only all-suture anchor tested. Tendons underwent cyclic loading from 10 to 100N for 500 cycles, followed by load-to-failure. Data was collected at cycles 5, 100, 200, 300, 400, and 500. One-way ANOVA analysis was used to assess significance (P≤0.05). The anchor combinations tested did not differ significantly in anterior (P>0.4) or posterior (P>0.3) gap formation, construct stiffness (P>0.7), ultimate load (P=0.06), or load to 5mm gap formation (P=0.84). The all-suture anchor demonstrated comparable biomechanical performance in multiple double-row anchor combinations to a combination of traditional solid-body anchors. Thus it may be an attractive option to further reduce the invasiveness of rotator cuff repairs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Noyes, Matthew P; Lederman, Evan; Adams, Christopher R; Denard, Patrick J
2018-05-01
To compare the biomechanical properties of single-row repair with triple-loaded (TL) anchor repair versus a knotless rip stop (KRS) repair in a rotator cuff repair model. Rotator cuff tears were created in 8 cadaveric matched-pair specimens and repaired with a TL anchor or KRS construct. In the TL construct, anchors were placed in the greater tuberosity and then all suture limbs were passed through the rotator cuff as simple sutures and tied. In the KRS construct, a 2-mm suture tape was passed through the tendon in an inverted mattress fashion, and a free suture was passed medial to the suture tape to create a rip-stop. Then, the suture tape and free suture were secured with knotless anchors. Displacement was observed with video tracking after cyclic loading, and specimens were loaded to failure. The mean load to failure was 438 ± 59 N in TL anchor repairs compared with 457 ± 110 N in KRS repairs (P = .582). The mean displacement with cyclic loading was 3.8 ± 1.6 mm in TL anchor repairs versus 4.3 ± 1.8 mm in the KRS group (P = .297). Mode of failure was consistent in both groups, with 6 of 8 failures in the TL anchor group and 7 of 8 failures in KRS group occurring from anchor pullout. There is no statistical difference in load to failure and cyclic loading between TL anchor and KRS single-row repair techniques. KRS repair technique may be an alternative method of repairing full-thickness supraspinatus tendon tears with a single-row construct. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Baums, M H; Buchhorn, G H; Gilbert, F; Spahn, G; Schultz, W; Klinger, H-M
2010-09-01
This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason-Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Group 4 showed lowest load-to-failure result with 155.7 +/- 31.1 N compared to group 1 (293.4 +/- 16.1 N) and group 2 (397.7 +/- 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 +/- 7.3 N/mm) and lowest in group 4 (84.4 +/- 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used.
Smith, Geoffrey C S; Bouwmeester, Theresia M; Lam, Patrick H
2017-12-01
In double-row SutureBridge (Arthrex, Naples, FL, USA) rotator cuff repairs, increasing tendon load may generate progressively greater compression forces at the repair footprint (self-reinforcement). SutureBridge rotator cuff repairs using tied horizontal mattress sutures medially may limit this effect compared with a knotless construct. Rotator cuff repairs were performed in 9 pairs of ovine shoulders. One group underwent repair with a double-row SutureBridge construct with tied horizontal medial-row mattress sutures. The other group underwent repair in an identical fashion except that medial-row knots were not tied. Footprint contact pressure was measured at 0° and 20° of abduction under loads of 0 to 60 N. Pull-to-failure tests were then performed. In both repair constructs, each 10-N increase in rotator cuff tensile load led to a significant increase in footprint contact pressure (P < .0001). The rate of increase in footprint contact pressure was greater in the knotless construct (P < .00022; ratio, 1.69). The yield point approached the ultimate load to failure more closely in the knotless model than in the knotted construct (P = .00094). There was no difference in stiffness, ultimate failure load, or total energy to failure between the knotless and knotted techniques. In rotator cuff repair with a double-row SutureBridge configuration, self-reinforcement is seen in repairs with and without medial-row knots. Self-reinforcement is greater with the knotless technique. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Biomechanical analysis of suture locations of the distal plantar fascia in partial foot.
Guo, Jun-Chao; Wang, Li-Zhen; Mo, Zhong-Jun; Chen, Wei; Fan, Yu-Bo
2015-12-01
The aim of this study was to evaluate the rationality of the suture locations of distal plantar fascia (DPF) after foot amputation to avoid the risk factors of re-amputation or plantar fasciitis. The tensile strain of plantar fascia (PF) in the different regions was measured by uni-axial tensile experiment. A three-dimensional (3D) finite element model was also developed to simulate tensile behaviour of PF in weight bearing conditions. The model includes 12 bones, ligaments, PF, cartilage and soft tissues. Four suture location models for the DPF were considered: the fourth and fifth DPF were sutured on the third metatarsal, the cuboid, and both the third metatarsal and the cuboid, and one un-sutured model. The peak tensile strain of the first, second and third PF was 0.134, 0.128 and 0.138 based on the mechanical test, respectively. The fourth and fifth DPF sutured at the cuboid and the third metatarsal could offer more favourable outcomes. The peak strain of 4.859 × 10(-2), 2.347 × 10(-2) and 1.364 × 10(-2) in the first, second and third PF showed the least outcomes in stance phase. Also, peak strain and stress of the residual PF reduced to 4.859 × 10(-2) and 1.834 MPa, respectively. The stress region was redistributed on the mid-shaft of the first and third PF and the peak stress of medial cuneiform bone evidently decreased. The fourth and fifth DPF suture at the third metatarsal and cuboid was appropriate for the partial foot. The findings are expected to suggest optimal surgical plan of the DPF suture and guide further therapeutic planning of partial foot patients.
Staple Line Reinforcement with Stitch in Laparoscopic Sleeve Gastrectomies. Is It Useful or Harmful?
Albanopoulos, Konstantinos; Tsamis, Dimitrios; Arapaki, Aggeliki; Kleidi, Eleftheria; Zografos, Georgios; Leandros, Emmanouil
2015-07-01
Reinforcement of the staple line in laparoscopic sleeve gastrectomy (LSG) is a practice that leads to less morbidity, but equivocal results have been reported in the literature. This is a prospective randomized study comparing two groups of patients who underwent LSG. In one group LSG was performed with a running absorbable suture placement at the staple line. In the other group the running suture was not placed. General data of the patients, as well as intraoperative and postoperative data, were gathered and statistically analyzed. Overall, 146 patients were subjected to LSG. In 84 patients a running suture was placed, and in 62 patients no suture was placed. No significant differences were found between the two groups in demographic data. No significant differences were found also in the intraoperative data, such as number of trocars, number and type of cartridges, drain placement, and operative time (45±21 versus 40±20 minutes, respectively; P<.05). Intraoperative complications were significantly more in the group with the suture placement (33.3% versus 16.1%, respectively; P<.05). Hematomas developed intraoperatively in more patients after the placement of the running suture (9.5% versus 0.0%, respectively; P<.05). Postoperatively, there was no significant difference in morbidity between the two groups (8.3% versus 9.7%, respectively; P>.05). After this randomized study, final conclusions about the efficacy of this running suture to the staple line cannot be made. To the contrary, problems seem to exist after such reinforcement of the staple line, such as hematomas. Dealing with possible leaks and hemorrhage of the staple line is also problematic after placement of the running suture.
Suturing training in Augmented Reality: gaining proficiency in suturing skills faster.
Botden, S M B I; de Hingh, I H J T; Jakimowicz, J J
2009-09-01
Providing informative feedback and setting goals tends to motivate trainees to practice more extensively. Augmented Reality simulators retain the benefit of realistic haptic feedback and additionally generate objective assessment and informative feedback during the training. This study researched the performance curve of the adapted suturing module on the ProMIS Augmented Reality simulator. Eighteen novice participants were pretrained on the MIST-VR to become acquainted with laparoscopy. Subsequently, they practiced 16 knots on the suturing module, of which the assessment scores were recorded to evaluate the gain in laparoscopic suturing skills. The scoring of the assessment method was calculated from the "time spent in the correct area" during the knot tying and the quality of the knot. Both the baseline knot and the knot at the top of the performance curve were assessed by two independent objective observers, by means of a standardized evaluation form, to objectify the gain in suturing skills. There was a statistically significant difference between the scores of the second knot (mean 72.59, standard deviation (SD) 16.28) and the top of the performance curve (mean 95.82, SD 3.05; p < 0.001, paired t-test). The scoring of the objective observers also differed significantly (mean 11.83 and 22.11, respectively; SD 3.37 and 3.89, respectively; p < 0.001) (interobserver reliability Cronbach's alpha = 0.96). The median amount of repetitions to reach the top of the performance curve was eight, which also showed significant differences between both the assessment score (mean 88.14, SD 13.53, p < 0.001) and scoring of the objective observers of the second knot (mean 20.51, SD 4.14; p < 0.001). This adapted suturing module on the ProMIS Augmented Reality laparoscopic simulator is a potent tool for gaining laparoscopic suturing skills.
Display Technology: An Annotated Bibliography.
1973-12-01
way in even the ’,test cockpit configurations. Why , then, should major changes be expected or sought? One reason for changes in cockpit...be no need for a separate navigator position, even on over- water routes, if the necessary information were displayed to another crew member, e.g. the...Burkowski, R. P., Kornblau, M., and Flint , W. L. Thermo- chromic Displays. Paper presented at NASA symposium on Recent Advances in Displ&y Media held in
Self-Assembled Soft Optical Negative Index Materials
2008-08-05
within the MURI indicated that anodization of aluminum films provides hexagonal nano-hole arrays, which, when backfilled with e.g. silver via...bath determine pore size and spacing. Then AAO is removed with chromic and phosphoric acid at 70°C for 6 hrs. A 2nd anodization results in hexagonal...array of pores. Anodization time sets membrane thickness. Pores widened in acid such as phosphoric acid. The barrier layer is thinned by gradually
Development of Azeotropic Blends to Replace TCE and nPB in Vapor Degreasing Operations
2016-12-21
vapor zone is fully contained and oxygen free, inexpensive and effective flammable solvents may be used. Working toward this type of process change...chlorine, chromic acid etc.) 7.2. Conditions for safe storage including any incompatibilities Store in a well- ventilated place. Store at temperatures ...Nausea, Dizziness, Headache, Exposure to and/or consumption of alcohol may increase toxic effects . To the best of our knowledge, the chemical
Figueiredo, Rubem L P; Dantas, Maria Sylvia Silva; Oréfice, Rodrigo L
2011-08-01
Sutures in cardiac valve bioprostheses have several disadvantages as they have to be manually processed and the suturing region is always a mechanically weak spot. Thermal welding of biological tissues has been evaluated as a means of replacing sutures by the direct application of heat to tissues. The mechanical strength of the welds increased up to 50°C and with lower degrees of humidity and longer times of welding. Chemical fixation was essential for the stability of the weld during re-hydration. The average mechanical strength of the welds (0.87 MPa) was lower than the strength of sutures (1.36 MPa) but some results showed strengths that were similar to sutures. Raman and electron micrographs showed that weld formation is primarily associated with chemical bonds between collagen fibers rather than chain flow and interpenetration.
Taylor, C J; Bansal, R; Pimpalnerkar, A
2006-09-01
Acute distal biceps rupture is a devastating injury in the young athlete and surgical repair offers the only chance of a full recovery. We report a new surgical technique used in 14 cases of acute distal tendon rupture in which the 'suture anchor technique' and a de-tensioning suture was employed. In this procedure the distal end of the biceps is re-attached to the radial tuberosity using a sliding whip stitch suture and the proximal part of the distal tendon repair attached to the underlying brachialis muscle with absorbable sutures. This restores correct anatomical alignment and isometric pull on the distal tendon and de-tensions the repair in the early post-operative period, allowing early rehabilitation and an early return to activity. In all cases patients regained a full pre-injury level of sporting activity at a mean period of 6.2 months (2-9 months).
Stable fixation with absorbable sutures in craniofacial surgery.
Linz, C; Kunz, F; Krauß, J; Böhm, H; Wirth, C; Hartmann, S; Wirbelauer, J; Schweitzer, T
2016-05-01
The present study analyses the exclusive use of absorbable suture material (Vicryl(®), Ethicon, Germany) in the fixation of transposed bone segments in craniofacial surgery without modification of the osteotomy design. Among 129 children up to 24 months of age, osteosynthesis was conducted exclusively with Vicryl(®) sutures. The stability of postoperative results was evaluated and possible foreign body reactions were examined within the framework of clinical and radiological routine checks. All examined children exhibited stable postoperative conditions while the length of hospital stay was not affected. X-ray examinations of the skull in two planes demonstrated good bony union in all cases. Relevant foreign body reactions were not observed. The exclusive application of absorbable suture material enables stable and cost effective osteosynthesis. Significant foreign body reactions were not observed. The exclusive use of absorbable sutures did not alter the osteotomy design. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
A multiphase transitioning peptide hydrogel for suturing ultrasmall vessels
NASA Astrophysics Data System (ADS)
Smith, Daniel J.; Brat, Gabriel A.; Medina, Scott H.; Tong, Dedi; Huang, Yong; Grahammer, Johanna; Furtmüller, Georg J.; Oh, Byoung Chol; Nagy-Smith, Katelyn J.; Walczak, Piotr; Brandacher, Gerald; Schneider, Joel P.
2016-01-01
Many surgeries are complicated by the need to anastomose, or reconnect, micrometre-scale vessels. Although suturing remains the gold standard for anastomosing vessels, it is difficult to place sutures correctly through collapsed lumen, making the procedure prone to failure. Here, we report a multiphase transitioning peptide hydrogel that can be injected into the lumen of vessels to facilitate suturing. The peptide, which contains a photocaged glutamic acid, forms a solid-like gel in a syringe and can be shear-thin delivered to the lumen of collapsed vessels (where it distends the vessel) and the space between two vessels (where it is used to approximate the vessel ends). Suturing is performed directly through the gel. Light is used to initiate the final gel-sol phase transition that disrupts the hydrogel network, allowing the gel to be removed and blood flow to resume. This gel adds a new tool to the armamentarium for micro- and supermicrosurgical procedures.
Craniosynostosis of the Lambdoid Suture
Rhodes, Jennifer L.; Tye, Gary W.; Fearon, Jeffrey A.
2014-01-01
Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement. PMID:25210507
Craniosynostosis of the lambdoid suture.
Rhodes, Jennifer L; Tye, Gary W; Fearon, Jeffrey A
2014-08-01
Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.
2012-11-09
The purpose of this report is to assess the performance of bi-directional knotless tissue-closure devices for use in tagging juvenile salmon. This study is part of an ongoing effort at Pacific Northwest National Laboratory (PNNL) to reduce unwanted effects of tags and tagging procedures on the survival and behavior of juvenile salmonids, by assessing and refining suturing techniques, suture materials, and tag burdens. The objective of this study was to compare the performance of the knotless (barbed) suture, using three different suture patterns (treatments: 6-point, Wide “N”, Wide “N” Knot), to the current method of suturing (MonocrylTM monofilament, discontinuous suturesmore » with a 2×2×2×2 knot) used in monitoring and research programs with a novel antiseptic barrier on the wound (“Second Skin”).« less
Celis, J; Ruiz, E; Berrospi, F; Payet, E
2001-01-01
To compare the leakage rate of esophagojejunal anastomosis performed with stapler or hand sutures. We studied a series of 367 patients who underwent total gastrectomy for gastric cancer at the Instituto de Enfermedades Neoplásicas (Lima-Peru) from 1986 to 1999. In 197 patients esophagojejunal anastomosis was performed with stapler and in 170 with manual sutures. There were no differences between both groups with regard to age, TNM stage, operating time and hospital stay. There were 8 anastomotic leakage (4.1%) in the stapler group and 4 (2.4%) in the hand sutures group (p> 0.05). Of these 12 cases, 2 patients (16%) died of causes directly related to the leak of the esophagojejunal anastomosis. There were no statistical differences in the rate of leakage of the esophagojejunal anastomosis performed with stapler or hand sutures, thus both techniques should be accepted as standard procedures.
The history of barbed sutures.
Ruff, Gregory L
2013-09-01
Ligatures have been used for millennia to close wounds. Sterilization and synthetic polymers that degrade in a commensurate fashion with wound healing have been the most significant improvements in these age-old devices. However, the constricting loop of a traditional suture and subsequent ischemia ("approximate, don't strangulate") still account for the most common cause of wound dehiscence-necrosis. Inspired by the quill of the North American porcupine, I envisioned a bidirectional array of barbs that could secure tissue without relying on constricting loops. One set of barbs could anchor the other. In this article, I document the development process of these barbed sutures from concept to patent to manufacture and US Food and Drug Administration approval. Knotless, strong, and easy to place, barbed sutures could foreseeably supplant conventional sutures, particularly as endoscopic procedures become more common. They also offer the intriguing potential to suspend ptotic tissues without surgical intervention.
Can, Ertuğrul; Koçak, Nurullah; Yücel, Özlem Eşki; Gül, Adem; Öztürk, Hilal Eser; Sayın, Osman
2016-01-01
Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes. PMID:27050346
Comparison of fibrin glue and Vicryl sutures in conjunctival autografting for pterygium surgery.
Wang, Xiu; Zhang, Yan; Zhou, Lei; Wei, Ruihua; Dong, Lijie
2017-01-01
To compare clinical parameters and the tear levels of inflammatory cytokines between pterygium surgery using sutures or fibrin glue. Fifty-six patients with primary pterygium were divided into the suture group and the glue group, in which the autograft was secured with 10-0 Vicryl sutures and fibrin glue, respectively. A questionnaire, slit-lamp examination, Schirmer test, and visual acuity test were performed in all participants. Real-time quantitative PCR (q-PCR) was used to analyze the expression of genes in pterygium and healthy conjunctival tissues. Based on the qPCR results and literature reports, five inflammatory cytokines, including hepatocyte growth factor (HGF), fibroblast growth factor 2 (FGF2), transforming growth factor-β1 (TGF-β1), matrix metalloproteinase 2 (MMP2), and tumor necrosis factor-α (TNF-α), were selected, and their protein levels were measured with enzyme-linked immunosorbent assay (ELISA) in patient tears before surgery as well as at postoperative day 1, 7, and 30. There are 28 patients in either the suture or the glue group. The average duration of surgery was 20.17 ± 3.23 min for the glue group and 32.42 ± 4.47 min for the suture group (p = 0.000). Visual acuity in both groups was improved (p = 0.002) after the surgical procedures. There were more symptoms in the suture group than in the glue group at postoperative day 7 (p = 0.002). Postoperative symptoms disappeared in both groups at 1 month after surgery. Recurrence was observed in one case in the glue group and in two cases in the suture group at the 6 month postoperative follow-up (p = 0.714). In comparison to the preoperative levels (4.33 ± 0.43 ng/ml for the suture group; 4.20 ± 0.26 ng/ml for the glue group), the levels of TNF-α in tears increased in the suture group (5.02 ± 0.49 ng/ml, p = 0.016) and decreased in the glue group (3.84 ± 0.35 ng/ml, p = 0.052) on postoperative day 1. The glue treatment induced higher HGF production (4.78 ± 1.25 ng/ml) than the suture treatment (3.04 ± 1.18 ng/ml) at postoperative day 1 (p = 0.020). Higher levels of TGF-β1 in the glue group were detected at postoperative day 1 (3.71 ± 0.18 ng/ml) and postoperative day 30 (4.50 ± 0.51 ng/ml), compared to those in the suture group, respectively (2.74 ± 0.21 ng/ml, p = 0.000 for day 1; 3.36 ± 0.96 ng/ml, p = 0.017 for postoperative day 30). Fibrin glue is effective and safe for attaching conjunctival autografts with an easy surgical procedure, shortened operating time, and less postoperative discomfort. In the early postoperative period, the protein expression of inflammatory cytokines implicates that fibrin glue may induce accelerated healing and subdued inflammation on the ocular surface compared to sutures.
Robot-assisted bronchoplasty using continuous barbed sutures
Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno
2018-01-01
We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors. PMID:29445589
Skin closure using staples and nylon sutures: a comparison of results.
Stockley, I; Elson, R A
1987-03-01
A disposable skin stapler (Elite: Auto Suture UK Ltd) and Nylon vertical mattress sutures have been used for skin closure. The complications related to each method were evaluated in 129 wounds. There was a higher incidence of inflammation, discomfort on removal and spreading of the healing scar associated with staples. The only advantage of staples was speed of wound closure.
A new suture technique avoids rib fractures and intercostal nerve trauma in thoracotomy.
Huang, Biaotong
2014-12-01
This article describes an alternative suture technique for thoracotomy incisions. A modified mattress suture technique is used to fix the intercostal muscles. The described technique can prevent rib fractures and reduce the incidence of intercostal nerve injury. Also, this technique is easy to perform and is effective. Georg Thieme Verlag KG Stuttgart · New York.
Interfascicular suture with nerve autografts for median, ulnar and radial nerve lesions.
Pluchino, F; Luccarelli, G
1981-05-01
Interfascicular nerve suture with autografts is the operation of choice for repairing peripheral nerve injuries because it ensures more precise alignment of the fasciculi and so better chances of reinnervation of the sectioned nerve. The procedure as described by Millesi et al has been used at the Istituto Neurologico di Milano in 30 patients with traumatic lesions of the median, ulnar and radial nerves. All have been followed up for 2 to 7 years since operation. The results obtained are compared with those of other series obtained with interfascicular suture and with epineural suture. Microsurgery is essential. The best time to operate is discussed.
Hashim, Peter W; Patel, Anup; Chang, Christopher C; Beckett, Joel S; Persing, John A
2014-01-01
Metopic synostosis represents an increasingly prevalent form of nonsyndromic craniosynostosis. Premature fusion of the metopic suture classically results in trigonocephaly, hypotelorism, temporal narrowing, and a pronounced midline forehead ridge. However, as varying degrees of skull deformity exist, there is confusion regarding the appropriate management for an infant with a metopic ridge. We report on a 2-month-old infant with clinical manifestations of metopic synostosis but with a patent metopic suture documented on computed tomography scan. We examine the implications for management related to fusion of the suture, age of the patient, and severity of the head deformity.
Lyu, J; Zhao, P-q
2016-01-01
Purpose We report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support. Materials and methods The technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels. Results The patients were followed for 5–14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications. Conclusion The simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs. PMID:26795420
Laparoscopic Suturing as a Barrier to Broader Adoption of Laparoscopic Surgery
Ghosh, Sudip; Niklewski, Paul; Roy, Sanjoy
2017-01-01
Background: Laparoscopic surgery is increasingly replacing the open procedure because of its many patient-related benefits that are well aligned with policies and programs that seek to optimize health system performance. However, widespread adoption of laparoscopic surgery has been slow, in part, because of the complexity of laparoscopic suturing. The objective of this study was to review the clinical and economic impacts of laparoscopic suturing in key procedures and to assess its role as a barrier to the broader adoption of laparoscopic surgery. Database: A medical literature search of MEDLINE, EMBASE, and BIOSIS from January 2010 through June 2016 identified 47 relevant articles. Conclusion: Laparoscopic suturing and intracorporeal knot tying may result in extended surgical time, complications, and surgeon errors, while improving patient quality of life through improved cosmesis, diet toleration, and better bowel movements. Despite advancement in surgical techniques and the availability of newer surgical tools, the complexity of laparoscopic suturing continues to be a barrier to greater adoption of MIS. The results of the study underscore the need for development of proficiency in laparoscopic suturing, which may help improve patient outcomes and reduce healthcare costs. PMID:28694682
Lyu, J; Zhao, P-Q
2016-05-01
PurposeWe report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support.Materials and methodsThe technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels.ResultsThe patients were followed for 5-14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications.ConclusionThe simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs.
Stapler vs suture closure of pancreatic remnant after distal pancreatectomy: a meta-analysis.
Zhou, Wei; Lv, Ran; Wang, Xianfa; Mou, Yiping; Cai, Xiujun; Herr, Ingrid
2010-10-01
Suture closure and stapler closure of the pancreatic remnant after distal pancreatectomy are the techniques used most often. The ideal choice remains a matter of debate. Five bibliographic databases covering 1970 to July 2009 were searched. Sixteen articles met the inclusion criteria. Stapler closure was performed in 671 patients, while suture closure was conducted in 1,615 patients. The pancreatic fistula rate ranged from 0% to 40.0% for stapler closure of the pancreatic stump and from 9.3% to 45.7% for the suture closure technique. There were no significant difference between the stapler and suture closure groups with respect to the pancreatic fistula formation rate (22.1% vs 31.2%; odds ratio, .85; 95% confidence interval, .66-1.08), although there was a trend toward favoring stapler closure. In 4 studies including 437 patients, stapler closure was associated with a trend (not statistically significant) toward a reduction in intra-abdominal abscess (odds ratio, .53; 95% confidence interval, .24-1.15). No significant differences occur between suture and stapler closure with respect to the pancreatic fistula or intra-abdominal abscess after distal pancreatectomy, though there is a trend favoring stapler closure. Copyright © 2010 Elsevier Inc. All rights reserved.
Weiss, William M; Saucedo, Ramon P; Robinson, John D; Lo, Chung-Chieh Jason; Morris, Randal P; Panchbhavi, Vinod K
2017-10-01
Refractory cases of Achilles tendinopathy amenable to surgery may include reattachment of the tendon using suture anchors. However, there is paucity of information describing the optimal insertion angle to maximize the tendon footprint and anchor stability in the calcaneus. The purpose of this investigation is to compare the fixation strength of suture anchors inserted at 90° and 45° (the Deadman's angle) relative to the primary compressive trabeculae of the calcaneus. A total of 12 matched pairs of adult cadaveric calcanei were excised and potted to approximate their alignment in vivo. Each pair was implanted with 5.5-mm bioabsorbable suture anchors placed either perpendicular (90°) or oblique (45°) to the primary compressive trabeculae. A tensile load was applied until failure of anchor fixation. Differences in failure load and stiffness between anchor fixation angles were determined by paired t-tests. No significant differences were detected between perpendicular and oblique suture anchor insertion relative to primary compressive trabeculae in terms of load to failure or stiffness. This investigation suggests that the fixation strength of suture anchors inserted perpendicular to the primary compression trabeculae and at the Deadman's angle are possibly comparable. Biomechanical comparison study.
Large Vertical Axis Rotations along Neotethyan Sutures in TURKEY
NASA Astrophysics Data System (ADS)
Ozkaptan, M.; Gulyuz, E.; Kaymakci, N.; Langereis, C. G.; Ozacar, A. A.; Lefebvre, C.
2014-12-01
Two Neotethyan Sutures,Izmir-Ankara and Intra-Tauride suture zones meet around Ankara region appx. at right angles.The northerly located Izmir-Ankara Suture zone follows approximately E-W trend and it makes a sharp approximately 90° bend at the east along the western margin of the Çankiri Basin.The Intra-Tauride suture follows approximately the Tuzgölü Fault Zone and trends NW-SE and seems to be overprinted by the structures related to the Izmir-Ankara suture zone. These two sutures meet southeastern corner of the Haymana Basin where the basin makes major eastwards counterclockwise bend.From west to East, the Haymana, Tuzgölü and Çankiri Basins straddle these suture zones and are developed in relation to the subduction and collision processes in the region, making them the perfect sites to unravel deformation history and paleogeography of the Neotethyan suture zones in the region. In order to accomplish this, the tectono-stratigraphic evolution of the basin and its paleogeographical positions, in different time slices, constructed by conducting a very detailed study on the Late Cretaceous to Recent infill of the Haymana, Tuzgölü, and Çankiri Basins. We collected more than 4500 sedimentary paleomagnetic samples for paleomagnetic purposes from 112 different locations within 250 km diameter area.Before the demagnetization process, nearly 3000 core specimens were measured for anisotropy of magnetic susceptibility (AMS) in order to understand deformation amounts and kinematics.The paleomagnetic results show that the region underwent strong clockwise and counterclockwise rotations more than 90° in places, resulting in the present geometry of the suture zones. The central part of the Haymana basin rotated as high as 90° counterclockwise while its northern part together with the southwestern part of the Çankiri basin and northern part of the Tuzgölü basin rotated approximately 30° clockwise contrary to almost all published paleomagnetic data from the region.The restored orientations based on this new paleomagnetic data indicate that Haymana, Tuzgölü Basin and the SW margin of the Çankiri basins were initially oriented N-S prior to Eocene.These results indicate that the most of the paleogeographical maps and evolutionary scenarios and models of the region requires major re-thinking and serious revisions.
Wang, Vincent M; Wang, Fan Chia; McNickle, Allison G; Friel, Nicole A; Yanke, Adam B; Chubinskaya, Susan; Romeo, Anthony A; Verma, Nikhil N; Cole, Brian J
2010-12-01
Rotator cuff repair retear rates range from 25% to 90%, necessitating methods to improve repair strength. Although numerous laboratory studies have compared single-row with double-row fixation properties, little is known regarding regional (ie, medial vs lateral) suture retention properties in intact and torn tendons. A torn supraspinatus tendon will have reduced suture retention properties on the lateral aspect of the tendon compared with the more medial musculotendinous junction. Controlled laboratory study. Human supraspinatus tendons (torn and intact) were randomly assigned for suture retention mechanical testing, ultrastructural collagen fibril analysis, or histologic testing after suture pullout testing. For biomechanical evaluation, sutures were placed either at the musculotendinous junction (medial) or 10 mm from the free margin (lateral), and tendons were elongated to failure. Collagen fibril assessments were performed using transmission electron microscopy. Intact tendons showed no regional differences with respect to suture retention properties. In contrast, among torn tendons, the medial region exhibited significantly higher stiffness and work values relative to the lateral region. For the lateral region, work to 10-mm displacement (1592 ± 261 N-mm) and maximum load (265 ± 44 N) for intact tendons were significantly higher (P < .05) than that of torn tendons (1086 ± 388 N-mm and 177 ± 71 N, respectively). For medial suture placement, maximum load, stiffness, and work of intact and torn tendons were similar (P > .05). Regression analyses for the intact and torn groups revealed generally low correlations between donor age and the 3 biomechanical indices. For both intact and torn tendons, the mean fibril diameter and area density were greater in the medial region relative to the lateral (P ≤ .05). In the lateral tendon, but not the medial region, torn specimens showed a significantly lower fibril area fraction (48.3% ± 3.8%) than intact specimens (56.7% ± 3.6%, P < .05). Superior pullout resistance of medially placed sutures may provide a strain shielding effect for the lateral row after double-row repair. Larger diameter collagen fibrils as well as greater fibril area fraction in the medial supraspinatus tendon may provide greater resistance to suture migration. While clinical factors such as musculotendinous integrity warrant strong consideration for surgical decision making, the present ultrastructural and biomechanical results appear to provide a scientific rationale for double-row rotator cuff repair where sutures are placed more medially at the muscle-tendon junction.
Pauly, Stephan; Kieser, Bettina; Schill, Alexander; Gerhardt, Christian; Scheibel, Markus
2010-10-01
Biomechanical comparison of different suture-bridge configurations of the medial row with respect to initial construct stability (time 0, porcine model). In 40 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected from their insertions. All specimens were operated on by use of the suture-bridge technique, only differing in terms of the medial-row suture-grasping configuration, and randomized into 4 groups: (1) single-mattress (SM) technique, (2) double-mattress (DM) technique, (3) cross-stitch (CS) technique, and (4) double-pulley (DP) technique. Identical suture anchors were used for all specimens (medial: Bio-Corkscrew FT 5.5 [Arthrex, Naples, FL]; lateral: Bio-PushLock 3.5 [Arthrex]). All repairs were cyclically loaded from 10 to 60 N until 10 to 200 N (20-N stepwise increase after 50 cycles each) with a material testing machine. Forces at 3 and 5 mm of gap formation, mode of failure, and maximum load to failure were recorded. The DM technique had the highest ultimate tensile strength (368.6 ± 99.5 N) compared with the DP (248.4 ± 122.7 N), SM (204.3 ± 90 N), and CS (184.9 ± 63.8 N) techniques (P = .004). The DM technique provided maximal force resistance until 3 and 5 mm of gap formation (90.0 ± 18.1 N and 128.0 ± 32.3 N, respectively) compared with the CS (72 ± 8.9 N and 108 ± 20.2 N, respectively), SM (66.0 ± 8.9 N and 90.0 ± 26.9 N, respectively), and DP (62.2 ± 6.2 N and 71 ± 13.2 N, respectively) techniques (P < .05 for each 3 and 5 mm of gap formation). The main failure mode was suture cutting through the tendon. Comparing the 4 different suture-bridge techniques, we found that modified application of suture-bridge repair with double medial mattress stitches significantly enhanced biomechanical construct stability at time 0 in this porcine ex vivo model. This technique increases initial stability and resistance to suture cutting through the rotator cuff tendon after arthroscopic suture-bridge repair. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears.
Milchteim, Charles; Branch, Eric A; Maughon, Ty; Hughey, Jay; Anz, Adam W
2016-04-01
Longitudinal meniscus tears are commonly encountered in clinical practice. Meniscus repair devices have been previously tested and presented; however, prior studies have not evaluated repair construct designs head to head. This study compared a new-generation meniscus repair device, SpeedCinch, with a similar established device, Fast-Fix 360, and a parallel repair construct to a crossed construct. Both devices utilize self-adjusting No. 2-0 ultra-high molecular weight polyethylene (UHMWPE) and 2 polyether ether ketone (PEEK) anchors. Crossed suture repair constructs have higher failure loads and stiffness compared with simple parallel constructs. The newer repair device would exhibit similar performance to an established device. Controlled laboratory study. Sutures were placed in an open fashion into the body and posterior horn regions of the medial and lateral menisci in 16 cadaveric knees. Evaluation of 2 repair devices and 2 repair constructs created 4 groups: 2 parallel vertical sutures created with the Fast-Fix 360 (2PFF), 2 crossed vertical sutures created with the Fast-Fix 360 (2XFF), 2 parallel vertical sutures created with the SpeedCinch (2PSC), and 2 crossed vertical sutures created with the SpeedCinch (2XSC). After open placement of the repair construct, each meniscus was explanted and tested to failure on a uniaxial material testing machine. All data were checked for normality of distribution, and 1-way analysis of variance by ranks was chosen to evaluate for statistical significance of maximum failure load and stiffness between groups. Statistical significance was defined as P < .05. The mean maximum failure loads ± 95% CI (range) were 89.6 ± 16.3 N (125.7-47.8 N) (2PFF), 72.1 ± 11.7 N (103.4-47.6 N) (2XFF), 71.9 ± 15.5 N (109.4-41.3 N) (2PSC), and 79.5 ± 25.4 N (119.1-30.9 N) (2XSC). Interconstruct comparison revealed no statistical difference between all 4 constructs regarding maximum failure loads (P = .49). Stiffness values were also similar, with no statistical difference on comparison (P = .28). Both devices in the current study had similar failure load and stiffness when 2 vertical or 2 crossed sutures were tested in cadaveric human menisci. Simple parallel vertical sutures perform similarly to crossed suture patterns at the time of implantation.
Ergin, Ömer Naci; Demirel, Mehmet; Özmen, Emre
2017-01-01
Rupture of the Achilles' tendon is a common injury occurring particularly in middle-aged men due to sports trauma. Operative treatment is preferred generally due to lower risk of re-rupture. Possible complications of the operation include suture granulomas. Suture granulomas might represent a foreign body reaction, which itself is the end-stage response of the inflammatory wound-healing process to biomaterials. It may occur with both absorbable and non-absorbable suture materials such as silk in our case. The aim of this study is to present a case of a delayed foreign body reaction 30 years after open repair of the Achilles tendon with silk sutures. Our case is a 38-year-old male who presented to our outpatient clinic with complaints of swelling and pain around the posterior region of the ankle for the past 3 months. He had a history of open Achilles tendon repair at the age of 3 at the site of complaints. Physical examination was positive for a mass under the incision scar. Magnetic resonance imaging report was positive for a granulomatosis formation. The patient was booked for an operation to remove the mass. Suture granuloma represents a tissue reaction against the suture material. Orthopedic literature is sparse for such cases and case reports. Both because of its rarity in orthopedic literature and the amount of time between the surgery and reaction, our report is a valuable addition to the literature.
Neodymium:yttrium-aluminum-garnet laser fusion of endarterectomy flaps.
Humphrey, P W; Slocum, M M; Loy, T S; Silver, D
1995-07-01
This study evaluated the efficacy of neodymium:yttrium-aluminum-garnet laser welding of flaps in canine arteries and in securing the distal flap during human carotid endarterectomy. Endarterectomy flaps were created in both common carotid and both common femoral arteries in 12 dogs. The flaps were repaired with either the neodymium:yttrium-aluminum-garnet laser or with 6-0 polypropylene sutures. The arteries were removed after duplex scanning at either 7 or 28 days. Eighteen high carotid endarterectomy flaps in 16 patients have been subsequently secured with the laser welding technique. Laser repairs (125 +/- 19 joule) of the canine arteries were completed more quickly than suture repairs (mean 25 seconds vs 135 seconds, respectively; p < 0.04). Duplex ultrasonography revealed no discernable differences between the two groups of arteries. Arteries studied at 7 days revealed three microscopic flaps (two suture, one laser), more subintimal fibroblastic proliferation in suture than laser-repaired carotid arteries (3: 1, p = 0.0530), and similar amounts of inflammation in suture- and laser-repaired arteries. Arteries studied at 28 days revealed one microscopic intimal flap (suture-repaired); equal fibroblastic and inflammatory responses in suture- and laser-repaired vessels; and no evidence of laser thermal injury. Eighteen carotid endarterectomy flaps have been successfully fused with no immediate or long-term complications in 16 patients (follow-up of 0 to 24 months). Laser fusion appears to be a safe and effective method for securing distal carotid endarterectomy flaps.
NASA Astrophysics Data System (ADS)
Kozlov, Valentine I.; Skobelkin, Oleg K.; Fatkullin, Ildar; Terman, Oleg A.; Chizhov, Gennadii; Gabidullina, Rushania
1994-12-01
To study the possibility of using Nd:YAG laser to weld the tissues of the uterus experiments in rats and dogs have been conducted. With the biomicroscopy and the laser Doppler flowmetry we have evaluated the microcirculation in the uterus wall under traditional suture and laser welding suture. As a model of the wound, the dissection of serosa and muscles of the organ wall have been used. In laser welding suture we have welded the zone of tissue about 1 mm3 with the laser (power density 270 W/cm2). Histological control has been fulfilled on various phases of the healing process. The investigation of the uterus wall demonstrates that there are zones of microcirculation disorders in tissues: (1) the zone of coagulation of microvessels and adjacent tissues (about 100 micrometers ); (2) the zone of stasis (150 - 200 micrometers ); (3) the zone of reactive-destructive changes of microvessels (300 micrometers ), (4) the zone of malfunctional microcirculatory changes (600 micrometers ). The coagulation of microvessels changes the character of inflammation and the healing process, decreases the exudation phase and the leucocyte infiltration of tissues, and accelerates the capillary growth. In contrast with traditional suture, in the case of laser welding suture the edema and hemorrhagic signs are less expressed. The complete restoration of microcirculation under laser welding suture has been observed by the fourteenth day of the healing process. Under the traditional suture method normalization of tissue nutritious blood flow has been achieved by 21 days.
The path of the superior sagittal sinus in unicoronal synostosis.
Russell, Aaron J; Patel, Kamlesh B; Skolnick, Gary; Woo, Albert S; Smyth, Matthew D
2014-10-01
This study investigates the anatomic relationship between the superior sagittal sinus (SSS) and the sagittal suture in infants with uncorrected unicoronal synostosis. The morphology of the SSS is also evaluated postoperatively to assess whether normalization of intracranial structures occurs following reconstruction. The study sample consisted of 20 computed tomography scans (10 preoperative, 6 postoperative, and 4 unaffected controls) obtained between 2001 and 2013. The SSS and the sagittal suture were outlined using Analyze imaging software. These data were used to measure the maximum lateral discrepancy between the SSS and the sagittal suture preoperatively and to assess for postoperative changes in the morphology of the SSS. In children with uncorrected unicoronal synostosis, the SSS deviates to the side of the patent coronal suture posteriorly and tends to follow the path of the sagittal and metopic sutures. The lateral discrepancy between the SSS and the sagittal suture ranged from 5.0 to 11.8 mm, with a 99.9 % upper prediction bound of 14.4 mm. Postoperatively, the curvature of the SSS was statistically decreased following surgical intervention, though it remained significantly greater than in unaffected controls. The SSS follows a predictable course relative to surface landmarks in children with unicoronal synostosis. When creating burr holes for craniotomies, the SSS can be avoided in 99.9 % of cases by remaining at least 14.4 mm from the lateral edge of the sagittal suture. Postoperative changes in the path of the SSS provide indirect evidence for normalization of regional brain morphology following fronto-orbital advancement.
Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F
2017-04-01
The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Effects of pico-tesla electromagnetic field treatment on wound healing in rats.
Trostel, C Todd; McLaughlin, Ron M; Lamberth, John G; Cooper, Robert C; Elder, Steven H; Pool, Roy R; Gao, Cheng; Cromiak, Joseph A; Boyle, Carolyn R
2003-07-01
To evaluate the effects of a pico-tesla electromagnetic field (PTEF) on healing of sutured and open skin wounds and clinicopathologic variables in rats. 64 male Fischer-344 rats. An incision made in the dorsal aspect of the neck was sutured (n = 32) or left open to heal (32). In each group, 16 rats were not PTEF-treated (controls). Wound treatment consisted of exposure to a PTEF once daily. Rats in each group were euthanatized at days 2, 4, 7, and 14. Wounds were evaluated via tensiometry (sutured wounds), digital planimetry (open wounds), laser Doppler perfusion imaging, bacteriologic culture, and histologic examination. Blood samples were collected from all rats for analysis. At day 14, sutured wounds in PTEF-treated rats were stronger (ultimate stress) and tougher (strain energy) than were sutured wounds in control rats. Open wounds in PTEF-treated rats contracted more quickly at days 2 and 4 than did those in control rats. Compared with control wounds, histologic changes (indicative of improved healing) in sutured and open wounds in PTEF-treated rats were detected as early as day 4. Laser Doppler perfusion measurements, results of CBCs, serum biochemical analyses, and bacteriologic cultures were not different between groups. Exposure to the PTEF caused no adverse effects on clinicopathologic, histologic, or bacteriologic variables tested in this study. It appears that PTEF is a safe form of adjuvant treatment for wounds and improves strength of sutured wounds and speeds contraction of open wounds.
Bio-inspired ``jigsaw''-like interlocking sutures: Modeling, optimization, 3D printing and testing
NASA Astrophysics Data System (ADS)
Malik, I. A.; Mirkhalaf, M.; Barthelat, F.
2017-05-01
Structural biological materials such as bone, teeth or mollusk shells draw their remarkable performance from a sophisticated interplay of architectures and weak interfaces. Pushed to the extreme, this concept leads to sutured materials, which contain thin lines with complex geometries. Sutured materials are prominent in nature, and have recently served as bioinspiration for toughened ceramics and glasses. Sutures can generate large deformations, toughness and damping in otherwise all brittle systems and materials. In this study we examine the design and optimization of sutures with a jigsaw puzzle-like geometry, focusing on the non-linear traction behavior generated by the frictional pullout of the jigsaw tabs. We present analytical models which accurately predict the entire pullout response. Pullout strength and energy absorption increase with higher interlocking angles and for higher coefficients of friction, but the associated high stresses in the solid may fracture the tabs. Systematic optimization reveals a counter-intuitive result: the best pullout performance is achieved with interfaces with low coefficient of friction and high interlocking angle. We finally use 3D printing and mechanical testing to verify the accuracy of the models and of the optimization. The models and guidelines we present here can be extended to other types of geometries and sutured materials subjected to other loading/boundary conditions. The nonlinear responses of sutures are particularly attractive to augment the properties and functionalities of inherently brittle materials such as ceramics and glasses.
Sherman, Seth L; Copeland, Marilyn E; Milles, Jeffrey L; Flood, David A; Pfeiffer, Ferris M
2016-06-01
To evaluate the biomechanical fixation strength of suture anchor and transosseous tunnel repair of the quadriceps tendon in a standardized cadaveric repair model. Twelve "patella-only" specimens were used. Dual-energy X-ray absorptiometry measurement was performed to ensure equal bone quality amongst groups. Specimens were randomly assigned to either a suture anchor repair of quadriceps tendon group (n = 6) or a transosseous tunnel repair group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 0.1 mm/s up to 100 N after which cyclic loading was applied at a rate of 1 Hz between magnitudes of 50 to 150 N, 50 to 200 N, 50 to 250 N, and tensile load at a rate of 0.1 mm/s until failure. Outcome measures included load to failure, displacement at 1st 100 N load, and displacement after each 10th cycle of loading. The measured cyclic displacement to the first 100 N, 50 to 150 N, 50 to 200 N, and 50 to 250 N was significantly less for suture anchors than transosseous tunnels. There was no statistically significant difference in ultimate load to failure between the 2 groups (P = .40). Failure mode for all suture anchors except one was through the soft tissue. Failure mode for all transosseous specimens but one was pulling the repair through the transosseous tunnel. Suture anchor quadriceps tendon repairs had significantly decreased gapping during cyclic loading, but no statistically significant difference in ultimate load to failure when compared with transosseous tunnel repairs. Although suture anchor quadriceps tendon repair appears to be a biomechanically superior construct, a clinical study is needed to confirm this technique as a viable alternative to gold standard transosseous techniques. Although in vivo studies are needed, these results support the suture anchor technique as a viable alternative to transosseous repair of the quadriceps tendon. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Incisionless otoplasty: a reliable and replicable technique for the correction of prominauris.
Mehta, Shaun; Gantous, Andres
2014-01-01
This study evaluates the postoperative outcomes achieved with incisionless otoplasty for the correction of prominauris. To determine whether incisionless otoplasty is a reliable and replicable technique in correcting prominauris. This study consisted of a retrospective electronic medical record review for 72 patients undergoing incisionless otoplasty for the correction of prominauris by a single surgeon from November 2006 to April 2013. Follow-up ranged from 1 to 87 months. The patients were operated on at both St Joseph's Health Centre (a community hospital) and The Cumberland Clinic (private practice) in Toronto, Ontario, Canada. All patients undergoing an incisionless otoplasty for the correction of prominauris were eligible. Participants' ages ranged from 3 to 55 years, with the majority being adults. Seventy patients were followed up for outcomes. Incisionless otoplasty. Number and type of sutures used, perioperative complications, and postoperative follow-up including complications and revisions. Complications included infection, hematoma, bleeding, perichondritis, suture granuloma, suture exposure, and suture failure. A mean (SD) 2.5 (0.8) sutures were used in the left ear, 2.48 (0.75) in the right ear, and 4.69 (1.75) in total. The number of sutures used in the left vs right ear was not significantly different (P = .60). All patients had horizontal mattress sutures placed for correction of prominauris. There were no serious perioperative complications such as infection, bleeding, hematoma, perichondritis, or cartilage necrosis. Follow-up data were extracted and analyzed in 70 patients, with a mean follow-up time of 31 months. Complications were seen in 10 patients (14%): 4 were due to suture failure, 3 were due to suture exposure, 2 were due to granuloma formation, and 1 was due to a Polysporin (bacitracin zinc/polymyxin B sulfate) reaction. Nine patients (13%) needed a revision to achieve a desirable result. The technique of incisionless otoplasty used in this study was well tolerated and effective in both pediatric and adult patients, producing favorable outcomes with minimal complications. This procedure is less invasive than its open counterpart and seems at least equally effective in longevity.
Judson, Christopher H.; Charette, Ryan; Cavanaugh, Zachary; Shea, Kevin P.
2016-01-01
Background: Traditional Bankart repair using bone tunnels has a reported failure rate between 0% and 5% in long-term studies. Arthroscopic Bankart repair using suture anchors has become more popular; however, reported failure rates have been cited between 4% and 18%. There have been no satisfactory explanations for the differences in these outcomes. Hypothesis: Bone tunnels will provide increased coverage of the native labral footprint and demonstrate greater load to failure and stiffness and decreased cyclic displacement in biomechanical testing. Study Design: Controlled laboratory study. Methods: Twenty-two fresh-frozen cadaveric shoulders were used. For footprint analysis, the labral footprint area was marked and measured using a Microscribe technique in 6 specimens. A 3-suture anchor repair was performed, and the area of the uncovered footprint was measured. This was repeated with traditional bone tunnel repair. For the biomechanical analysis, 8 paired specimens were randomly assigned to bone tunnel or suture anchor repair with the contralateral specimen assigned to the other technique. Each specimen underwent cyclic loading (5-25 N, 1 Hz, 100 cycles) and load to failure (15 mm/min). Displacement was measured using a digitized video recording system. Results: Bankart repair with bone tunnels provided significantly more coverage of the native labral footprint than repair with suture anchors (100% vs 27%, P < .001). Repair with bone tunnels (21.9 ± 8.7 N/mm) showed significantly greater stiffness than suture anchor repair (17.1 ± 3.5 N/mm, P = .032). Mean load to failure and gap formation after cyclic loading were not statistically different between bone tunnel (259 ± 76.8 N, 0.209 ± 0.064 mm) and suture anchor repairs (221.5 ± 59.0 N [P = .071], 0.161 ± 0.51 mm [P = .100]). Conclusion: Bankart repair with bone tunnels completely covered the footprint anatomy while suture anchor repair covered less than 30% of the native footprint. Repair using bone tunnels resulted in significantly greater stiffness than repair with suture anchors. Load to failure and gap formation were not significantly different. PMID:26779555
Judson, Christopher H; Charette, Ryan; Cavanaugh, Zachary; Shea, Kevin P
2016-01-01
Traditional Bankart repair using bone tunnels has a reported failure rate between 0% and 5% in long-term studies. Arthroscopic Bankart repair using suture anchors has become more popular; however, reported failure rates have been cited between 4% and 18%. There have been no satisfactory explanations for the differences in these outcomes. Bone tunnels will provide increased coverage of the native labral footprint and demonstrate greater load to failure and stiffness and decreased cyclic displacement in biomechanical testing. Controlled laboratory study. Twenty-two fresh-frozen cadaveric shoulders were used. For footprint analysis, the labral footprint area was marked and measured using a Microscribe technique in 6 specimens. A 3-suture anchor repair was performed, and the area of the uncovered footprint was measured. This was repeated with traditional bone tunnel repair. For the biomechanical analysis, 8 paired specimens were randomly assigned to bone tunnel or suture anchor repair with the contralateral specimen assigned to the other technique. Each specimen underwent cyclic loading (5-25 N, 1 Hz, 100 cycles) and load to failure (15 mm/min). Displacement was measured using a digitized video recording system. Bankart repair with bone tunnels provided significantly more coverage of the native labral footprint than repair with suture anchors (100% vs 27%, P < .001). Repair with bone tunnels (21.9 ± 8.7 N/mm) showed significantly greater stiffness than suture anchor repair (17.1 ± 3.5 N/mm, P = .032). Mean load to failure and gap formation after cyclic loading were not statistically different between bone tunnel (259 ± 76.8 N, 0.209 ± 0.064 mm) and suture anchor repairs (221.5 ± 59.0 N [P = .071], 0.161 ± 0.51 mm [P = .100]). Bankart repair with bone tunnels completely covered the footprint anatomy while suture anchor repair covered less than 30% of the native footprint. Repair using bone tunnels resulted in significantly greater stiffness than repair with suture anchors. Load to failure and gap formation were not significantly different.
Guan, Xiaoming; Ma, Yingchun; Gisseman, Jordan; Kleithermes, Christopher; Liu, Juan
2017-01-01
To demonstrate the tips and tricks of a simpler technique for single-site sacrocolpopexy using barbed suture anchoring and retroperitoneal tunneling to make the procedure more efficient and reproducible. Step-by-step description of surgical tutorial using a narrated video (Canadian Task Force classification III). Academic tertiary care hospital. Patient with Stage III uterine prolapse. Sacrocolpopexy is increasing utilized since the FDA warning about complications of vaginal mesh surgery. It is the gold standard for repair of apical prolapse. However, there is great variation in the sacrocolpopexy procedure techniques and they have not been standardized. Traditional single-site laparoscopic sacrocolpopexy is very challenging as the procedure time is long and suturing is difficult. The advantages of suturing with wristed needle drivers in robotic single-site surgery simplify this complex procedure. Furthermore, using barbed suture anchoring and peritoneal tunneling technique potentially decreases the surgeon's learning curve and makes the procedure reproducible. In this video, we demonstrate a supracervial hysterectomy with a stepwise explanation of the correct technique for performing a robotic single incision sacrocolpopexy. Sacrocolpopexy is increasing used since the US Food and Drug Administration warning about complications of vaginal mesh surgery. It is the gold standard for repair of apical prolapse. However, a great variation exists in the sacrocolpopexy procedure techniques that need to be standardized. Traditional single-site laparoscopic sacrocolpopexy is very challenging because the procedure time is long and suturing is difficult. The advantages of suturing with wristed needle drivers in robotic single-site surgery simplify this complex procedure. Furthermore, using the barbed suture anchoring and peritoneal tunneling technique potentially decreases the surgeon's learning curve and makes the procedure reproducible. In this video, we demonstrate a supracervical hysterectomy with a stepwise explaation of the correct technique for performing a robotic single-incision sacrocolpopexy. The possibility of using the barbed suture and peritoneal tunneling technique with wristed needle drivers in robotic single-site sacrocolpopexy offers the possibility of an effective, safe, reproducible, and cosmetic surgical option. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.
Li, Hong-Yun; Hua, Ying-Hui; Wu, Zi-Ying; Chen, Bo; Chen, Shi-Yi
2013-11-01
The purpose of this study was to compare the biomechanical characteristics of fixation with 2-suture anchors versus transosseous tunnel fixation in anatomic reconstruction of the ankle lateral ligaments. Six matched pairs of human cadaveric ankles underwent anatomic lateral ankle reconstruction, and fixation of the graft on the talus was achieved with 2 suture anchors or a transosseous tunnel. Ankles for the transosseous tunnel group were chosen at random, with the paired contralateral ankles used for the 2-suture anchor group. Half of the peroneus brevis tendon was harvested as a graft. For each technique, one end of the tendon was secured to the original insertion point of the anterior talofibular ligament (ATFL) at the talus, whereas the other end was armed with 2 No. 5 nonabsorbable sutures (Ethicon, Somerville, NJ) and passed through the bone tunnel in the fibula. Biomechanical testing was performed by applying the force in line with the graft. Load to failure was determined at a displacement rate of 50 mm/min. The load-displacement curve, maximum load at failure (N), and stiffness (N/mm) were recorded and compared between the 2 techniques. There was no difference between constructs in the 2-suture anchor group and the transosseous tunnel group in terms of the ultimate load and stiffness (161.8 ± 47.6 N v 171.9 ± 76.0 N; P = .92; 4.59 ± 1.85 N/mm v 5.77 ± 1.98 N/mm; P = .35). Most constructs failed because of anchor pullout in the 2-suture anchor group (5 of 6) and fracture of the bony bridge in the transosseous tunnel group (6 of 6). The strength of fixation with suture anchors in anatomic reconstruction of the ankle lateral ligaments was equivalent to transosseous tunnel fixation as determined with biomechanical testing. However, this study did not prove that one is advantageous over the other. Both techniques showed excellent biomechanical results. Therefore, the 2-suture anchor fixation approach can be safely used in anatomic reconstruction of the ankle lateral ligaments. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Thread-Lift Sutures: Still in the Lift? A Systematic Review of the Literature.
Gülbitti, Haydar Aslan; Colebunders, Britt; Pirayesh, Ali; Bertossi, Dario; van der Lei, Berend
2018-03-01
In 2006, Villa et al. published a review article concerning the use of thread-lift sutures and concluded that the technique was still in its infancy but had great potential to become a useful and effective procedure for nonsurgical lifting of sagged facial tissues. As 11 years have passed, the authors now performed again a systematic review to determine the real scientific current state of the art on the use of thread-lift sutures. A systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines using the PubMed database and using the Medical Subject Headings search term "Rhytidoplasty." "Rhytidoplasty" and the following entry terms were included by this Medical Subject Headings term: "facelift," "facelifts," "face Lift," "Face Lifts," "Lift," "Face," "Lifts," "Platysmotomy," "Platysmotomies," "Rhytidectomy," "Rhytidectomies," "Platysmaplasty," "and "Platysmaplasties." The Medical Subject Headings term "Rhytidoplasty" was combined with the following search terms: "Barbed suture," "Thread lift," "APTOS," "Suture suspension," "Percutaneous," and "Silhouette suture." RefWorks was used to filter duplicates. Three of the authors (H.A.G., B.C., and B.L.) performed the search independently. The initial search with all search terms resulted in 188 articles. After filtering the duplicates and the articles about open procedures, a total of 41 articles remained. Of these, the review articles, case reports, and letters to the editor were subsequently excluded, as were reports dealing with nonbarbed sutures, such as Vicryl and Prolene with Gore-Tex. This resulted in a total of 12 articles, seven additional articles since the five articles reviewed by Villa et al. The authors' review demonstrated that, within the past decade, little or no substantial evidence has been added to the peer-reviewed literature to support or sustain the promising statement about thread-lift sutures as made by Villa et al. in 2006 in terms of efficacy or safety. All included literature in the authors' review, except two studies, demonstrated at best a very limited durability of the lifting effect. The two positive studies were sponsored by the companies that manufacture the thread-lift sutures.
Determination of Fluorine in Fluoro-Organic Compounds in Low Concentrations in Air
1944-06-27
Analysis of 2-Fluoroethanol in Air ..... SUMMARY BIBLIOGRAPHY 15 APPENDIX , 16 FIGURE 1 Apparatus PLATE 1 CDS Scrubber SECRET ) SECRET...liter, and 68$ at 1 - 2 mg. per liter. By using two scrubbers in series, 90$ of di-isopropyl fluorophosphate was recovered at a concentration of 1 to 2...chromic acid and detection of HP by etching of the glass container ; (5) scrub- bing the gas with ammonia and decomposing the fluoro-organic compound4
NASA preprototype redox storage system for a photovoltaic stand-alone application
NASA Technical Reports Server (NTRS)
Hagedorn, N. H.
1981-01-01
A 1 kW preprototype redox storage system underwent characterization tests and was operated as the storage device for a 5 kW (peak) photovoltaic array. The system is described and performance data are presented. Loss mechanisms are discussed and simple design changes leading to significant increases in efficiency are suggested. The effects on system performance of nonequilibrium between the predominant species of complexed chromic ion in the negative electrode reactant solution are indicated.
CHRIS. Response Methods Handbook.
1978-12-01
ssnrlc and a liIiqtiid porn pI to rc novc colicted material, t hereby convcert in ile wSNStcl ii ito a cOn tin iiooS proccss. Most vacuum i systemirs...cid50 PF FGE F G.E P G Forelelud40% P G.E E P Chromic: kcid Eon. P P,F C Foroalehyle G.E E C E P I Citric kid G.E E C E P C Formic kcid 10% F.C.C G.E
Hexavalent chromium exposures during full-aircraft corrosion control.
Carlton, Gary N
2003-01-01
Aluminum alloys used in the construction of modern aircraft are subject to corrosion. The principal means of controlling this corrosion in the U.S. Air Force are organic coatings. The organic coating system consists of a chromate conversion coat, epoxy resin primer, and polyurethane enamel topcoat. Hexavalent chromium (CrVI) is present in the conversion coat in the form of chromic acid and in the primer in the form of strontium chromate. CrVI inhalation exposures can occur when workers spray conversion coat onto bare metal and apply primer to the treated metal surface. In addition, mechanical abrasion of aircraft surfaces can generate particulates that contain chromates from previously applied primers and conversion coats. This study measured CrVI exposures during these corrosion control procedures. Mean time-weighted average (TWA) exposure to chromic acid during conversion coat treatment was 0.48 microg/m(3), below the current American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV(R)) TWA of 50 microg/m(3) for water-soluble CrVI compounds. Mean TWA exposures to strontium chromate were 5.33 microg/m(3) during mechanical abrasion and 83.8 microg/m(3) during primer application. These levels are in excess of the current ACGIH TLV-TWA of 0.5 microg/m(3) for strontium chromate. In the absence of a change from chromated to nonchromated conversion coats and primers, additional control measures are needed to reduce these exposures.
Neutron response of GafChromic® EBT2 film
NASA Astrophysics Data System (ADS)
Hsiao, Ming-Chen; Liu, Yuan-Hao; Chen, Wei-Lin; Jiang, Shiang-Huei
2013-03-01
Neutron and gamma-ray mixed field dosimetry remains one of the most challenging topics in radiation dosimetry studies. However, the requirement for accurate mixed field dosimetry is increasing because of the considerable interest in high-energy radiotherapy machines, medical ion beams and BNCT epithermal neutron beams. Therefore, this study investigated the GafChromic® EBT2 film. The linearity, reproducibility, energy dependence and homogeneity of the film were tested in a 60Co medical beam, 6-MV LINAC and 10-MV LINAC. The linearity and self-developing effect of the film irradiated in an epithermal neutron beam were also examined. These basic detector characteristics showed that EBT2 film can be effectively applied in mixed field dosimetry. A general detector response model was developed to determine the neutron relative effectiveness (RE) values. The RE value of fast neutrons varies with neutron spectra. By contrast, the RE value of thermal neutrons was determined as a constant; it is only 32.5% in relation to gamma rays. No synergy effect was observed in this study. The lithium-6 capture reaction dominates the neutron response in the thermal neutron energy range, and the recoil hydrogen dose becomes the dominant component in the fast neutron energy region. Based on this study, the application of the EBT2 film in the neutron and gamma-ray mixed field is feasible.
Weigert, M; Mellerowicz, H; Werhahn, C
1975-10-01
Isolated division of the tibial nerve in the thigh preserving the peroneal and sural nerves does not cause loss of normal position of the animal, in particular of sitting. Nor does it lead to pressure sores. The animals are fitter then after division of the sciatic nerve. Microsurgical suture of the isolated tibial nerve in the thigh of the rabbit with 1 or 2 simple sutures with 10 x 0 thread show that an average recovery can be achieved in over 80 per cent. As few sutures as possible should be used. Otherwise there with be scarring and no return of function.
Lui, T H
2015-01-01
Eckert and Davis grade 3 superior peroneal retinaculum injury is rare and the optimal treatment is not yet determined. A 57 year-old lady sprained her left ankle resulting in grade 3 injury of the superior peroneal retinaculum and was treated by endoscopic retinaculum reconstruction. The fracture healed and the peroneal tendons were stabilized. However, it was complicated by protusion of the suture anchors into the posterolateral ankle gutter. The implants were successfully removed endoscopically. Proper selection of the size and dimension of the suture anchor and preoperative planning with computed tomogram is important for usage of suture anchors in the lateral malleolus.
Arthroscopic meniscal repair with use of the outside-in technique.
Rodeo, S A
2000-01-01
The outside-in technique of arthroscopic repair is effective for repair of most meniscal tears. The overall indications for the use of this technique are similar to those for the commonly used inside-out technique. The outside-in technique is especially useful for suturing the anterior horn of the meniscus as well as for suturing meniscal replacement devices such as a collagen meniscal implant or a meniscal allograft. Other specific advantages of this technique include the ability to predictably avoid neurovascular injury without the need for a large posterior incision. A particular disadvantage is the difficulty of achieving perpendicular orientation of sutures when a tear is adjacent to the site of attachment of the posterior horn. Use of the inside-out technique or an all-inside implant is suggested for these tears. The use of this suturing technique is facilitated by attention to several technical points. The knee should be maintained in flexion for repair of tears of the lateral meniscus (to avoid injury to the peroneal nerve) and in nearly full extension for repair of the posterior aspect of the medial meniscus (to avoid injury to the saphenous nerve and its branches). Care must be taken to avoid tying the sutures around a branch of the saphenous nerve during repair of the medial meniscus. The sutures should be retrieved through a cannula in the anterior portal to avoid the entrapment of the sutures in soft tissue. A probe can be used to prevent displacement of the inner fragment of a bucket handle tear when the needles are placed across the tear, as the entering needles may push the torn fragment into the knee. A vertical suture orientation is preferred in order to evenly co-apt the meniscus to the capsule. If knot-end sutures (so-called Mulberry knots) are used, 2 sutures can be vertically stacked, with 1 on each surface of the meniscus. If a mattress suture is used, a vertical orientation is easily achieved with the outside-in technique. Use of an exogenous fibrin clot is suggested for isolated tears. The clot can be secured to the site of repair by a suture that has been placed through a spinal needle with the outside-in method. Delayed weightbearing should be considered as postoperative management for patients who have had repair of a tear with a radial component or repair of a complex tear in which a fibrin clot was used. Previous studies have demonstrated that the location of the tear and the condition of the anterior cruciate ligament are important factors in determining the success of meniscal repair. The overall results with use of the outside-in technique are comparable with those reported with use of the inside-out method. Patients with concomitant tears of the medial meniscus and the anterior cruciate ligament should have combined meniscal repair and reconstruction of the anterior cruciate ligament. As healing was demonstrated in 8 of 13 patients with an unrepaired tear of the anterior cruciate ligament, consideration should still be given to meniscal repair in patients who refuse reconstruction of the anterior cruciate ligament. In this setting, it may be advisable to use multiple permanent sutures, and the patient must be counseled regarding the higher rate of failure with this approach. Repairs of the lateral meniscus have a higher rate of success, and repair of the lateral meniscus should be considered even in the presence of injury of the anterior cruciate ligament.
Alcántara, Cristina; Sarmiento-Rubiano, Luz Adriana; Monedero, Vicente; Deutscher, Josef; Pérez-Martínez, Gaspar; Yebra, María J.
2008-01-01
Sequence analysis of the five genes (gutRMCBA) downstream from the previously described sorbitol-6-phosphate dehydrogenase-encoding Lactobacillus casei gutF gene revealed that they constitute a sorbitol (glucitol) utilization operon. The gutRM genes encode putative regulators, while the gutCBA genes encode the EIIC, EIIBC, and EIIA proteins of a phosphoenolpyruvate-dependent sorbitol phosphotransferase system (PTSGut). The gut operon is transcribed as a polycistronic gutFRMCBA messenger, the expression of which is induced by sorbitol and repressed by glucose. gutR encodes a transcriptional regulator with two PTS-regulated domains, a galactitol-specific EIIB-like domain (EIIBGat domain) and a mannitol/fructose-specific EIIA-like domain (EIIAMtl domain). Its inactivation abolished gut operon transcription and sorbitol uptake, indicating that it acts as a transcriptional activator. In contrast, cells carrying a gutB mutation expressed the gut operon constitutively, but they failed to transport sorbitol, indicating that EIIBCGut negatively regulates GutR. A footprint analysis showed that GutR binds to a 35-bp sequence upstream from the gut promoter. A sequence comparison with the presumed promoter region of gut operons from various firmicutes revealed a GutR consensus motif that includes an inverted repeat. The regulation mechanism of the L. casei gut operon is therefore likely to be operative in other firmicutes. Finally, gutM codes for a conserved protein of unknown function present in all sequenced gut operons. A gutM mutant, the first constructed in a firmicute, showed drastically reduced gut operon expression and sorbitol uptake, indicating a regulatory role also for GutM. PMID:18676710
Fujii, Masataka; Furumatsu, Takayuki; Xue, Haowei; Miyazawa, Shinichi; Kodama, Yuya; Hino, Tomohito; Kamatsuki, Yusuke; Ozaki, Toshifumi
2017-10-01
The purpose of this study was to compare the load-to-failure of different common suturing techniques with a new technique for the medial meniscus posterior root tear (MMPRT). Thirty porcine medial menisci were randomly assigned to three suturing techniques used for transtibial pullout repair of the MMPRT (n = 10 per group). Three different meniscal suture configurations were studied: the two simple suture (TSS) technique, the conventional modified Mason-Allen suture (MMA) technique, and the new MMA technique using the FasT-Fix combined with the Ultrabraid (F-MMA). The ultimate failure load was tested using a tensile testing machine. The MMA and F-MMA groups demonstrated significantly higher failure loads than the TSS group (P = 0.0003 and P = 0.0005, respectively). No significant differences were observed between the MMA and F-MMA groups (P = 0.734). The ultimate failure load was significantly greater in the F-MMA than the TSS group and similar to the conventional MMA technique.
Ludwig, C; Behrend, M; Hoffarth, U; Schüttler, W; Stoelben, E
2004-09-01
This study was aimed to determine the resistance to pressure of manual and stapled bronchial closures under ideal conditions (90 degrees to the bronchial tree) and parallel to the trachea (45 degrees). An experimental study was done on 60 explanted pig tracheae which were alternatively closed with either double-layer, running sutures angled 90 degrees to the cartilaginous rings or an automatic stapling device. The closure line was placed exactly 90 degrees to the bronchial tree in 30 cases and parallel to the trachea (45 degrees) in 30. The sutures were placed under pressure until air leakage was observed. The leakage pressure was digitally recorded. A statistically significant difference existed between the two groups. Mechanical sutures proved more resistant to pressure (P=0.011). Under ideal conditions, the resistance to pressure of mechanical sutures is equal to if not better than that of manual sutures.
Fujimoto, S; Takahashi, M; Endoh, F; Takai, M; Kobayashi, K; Kiuchi, S; Konno, C; Obata, G; Okui, K
1991-09-01
From January 1983 to December 1989, we performed esophagojejunostomy on 379 patients who underwent total gastrectomy for gastric cancer. A mechanical EEA stapler or conventional manual suturing was used. The clinical outcomes of 199 patients in whom stapling was used (stapler group) and 180 patients in whom manual suturing was done (manual group) were compared. Two of the 199 patients in the stapler group and 3 of the 180 patients in the manual group died of causes directly related to the anastomosis. In the stapler group, 16 stapled anastomoses were formed supradiaphragmatically, and manual suturing was done for 6 patients. The highly placed anastomosis was formed without left thoracotomy or with median sternotomy in 8 of the 16 patients in whom the stapling device was used and in 1 of the 6 patients in whom manual suturing was used. The incidence of anastomotic leakage and stenosis did not differ between the groups. Thus, the mechanical stapler facilitated the construction of a rapid, reliable esophagojejunostomic anastomosis.
Virtual suturing simulation based on commodity physics engine for medical learning.
Choi, Kup-Sze; Chan, Sze-Ho; Pang, Wai-Man
2012-06-01
Development of virtual-reality medical applications is usually a complicated and labour intensive task. This paper explores the feasibility of using commodity physics engine to develop a suturing simulator prototype for manual skills training in the fields of nursing and medicine, so as to enjoy the benefits of rapid development and hardware-accelerated computation. In the prototype, spring-connected boxes of finite dimension are used to simulate soft tissues, whereas needle and thread are modelled with chained segments. Spherical joints are used to simulate suture's flexibility and to facilitate thread cutting. An algorithm is developed to simulate needle insertion and thread advancement through the tissue. Two-handed manipulations and force feedback are enabled with two haptic devices. Experiments on the closure of a wound show that the prototype is able to simulate suturing procedures at interactive rates. The simulator is also used to study a curvature-adaptive suture modelling technique. Issues and limitations of the proposed approach and future development are discussed.
Comprehensive Review of Tissue Adhesives.
Jenkins, Lauren E; Davis, Loretta S
2018-06-19
Cyanoacrylates, also known as tissue adhesives or skin glues, are commonly used as sealants for lacerations and incisions and have found utility in excisional and cosmetic surgeries in both outpatient and operating room settings. To review the surgical literature on the utilities, advantages, disadvantages, and special uses of cyanoacrylates applicable to dermatology. PubMed was reviewed for relevant articles related to cyanoacrylates and their use in skin closures. Articles unrelated to cutaneous closures were excluded. Tissue adhesives polymerize to a water resistant, pliable film after application to approximated wound edges and have antibacterial properties. Adhesives slowly slough off as the wound heals, typically after 5 days. Compared with 5-0 nonabsorbable suture, adhesives provide similar tensile strength and similar patient and surgeon satisfaction. Although slightly more expensive than sutures, tissue adhesives obviate the need for wound dressings and suture removal. They do not perform as well as sutures for wounds under higher tension or in the setting of moisture and inadequate hemostasis. Cyanoacrylates serve as a safe and effective suture alternative in appropriate dermatologic surgeries and procedures.
The suture provides a niche for mesenchymal stem cells of craniofacial bones
Zhao, Hu; Feng, Jifan; Ho, Thach-Vu; Grimes, Weston; Urata, Mark; Chai, Yang
2015-01-01
Bone tissue undergoes constant turnover supported by stem cells. Recent studies showed that perivascular mesenchymal stem cells (MSCs) contribute to the turnover of long bones. Craniofacial bones are flat bones derived from a different embryonic origin than the long bones. The identity and regulating niche for craniofacial bone MSCs remain unknown. Here, we identify Gli1+ cells within the suture mesenchyme as the major MSC population for craniofacial bones. They are not associated with vasculature, give rise to all craniofacial bones in the adult and are activated during injury repair. Gli1+ cells are typical MSCs in vitro. Ablation of Gli1+ cells leads to craniosynostosis and arrest of skull growth, indicating these cells are an indispensible stem cell population. Twist1+/− mice with craniosynostosis show reduced Gli1+ MSCs in sutures, suggesting that craniosynostosis may result from diminished suture stem cells. Our study indicates that craniofacial sutures provide a unique niche for MSCs for craniofacial bone homeostasis and repair. PMID:25799059
Kumashiro, R; Sano, C; Ugaeri, H; Madokoro, S; Maekawa, T; Kumamoto, M; Hideshima, T; Inutsuka, S
1994-04-01
Instead of a linear stapler or manual pursestring suture onto the lower part of the rectum, we placed a No. 2-0 Prolene suture on the edge of the rectal stump, using 12 to 16 clips and a disposable skin stapler. This technique is satisfactory for very low anterior resection.
Principles of Basic Wound Evaluation and Management in the Emergency Department
2007-01-01
children. Equally acceptable cosmetic results were found when absorbable suture was compared with the use of nonabsorbable suture in pediatric facial ...compared with both nonabsorbable and absorb - able sutures [71]. Octyl-cyanoacrylates may be used in other areas of the body with low skin tension, but...71] Holger JS, Wnadersee SC, Hale DB, et al. Cosmetic outcomes of facial lacerations repaired with tissue adhesive, absorbable and non- absorbable
Bowel anastomoses: The theory, the practice and the evidence base
Goulder, Frances
2012-01-01
Since the introduction of stapling instruments in the 1970s various studies have compared the results of sutured and stapled bowel anastomoses. A literature search was performed from 1960 to 2010 and articles relating to small bowel, colonic and colorectal anastomotic techniques were reviewed. References from these articles were also reviewed, and relevant articles obtained. Either a stapled or sutured gastrointestinal tract anastomosis is acceptable in most situations. The available evidence suggests that in the following situations, however, particular anastomotic techniques may result in fewer complications: A stapled side-to-side ileocolic anastomosis is preferable following a right hemicolectomy for cancer. A stapled side-to-side anastomosis is likely also preferable after an ileocolic resection for Crohn’s disease. Colorectal anastomoses can be sutured or stapled with similar results, although the incidence of strictures is higher following stapled anastomoses. Following reversal of loop ileostomy there is some evidence to suggest that a stapled side-to-side anastomosis or sutured enterotomy closure (rather than spout resection and sutured anastomosis) results in fewer complications. Non-randomised data has indicated that small bowel anastomoses are best sutured in the trauma patient. This article reviews the theory, practice and evidence base behind the various gastrointestinal anastomoses to help the practising general surgeon make evidence based operative decisions. PMID:23293735
Gaspardone, Achille; De Marco, Federico; Sgueglia, Gregory A; De Santis, Antonella; Iamele, Maria; D'Ascoli, Emanuela; Tusa, Maurizio; Corciu, Anca; Mullen, Michael; Nobles, Anthony; Carminati, Mario; Bedogni, Francesco
2018-04-03
To assess the efficacy of a novel percutaneous "device-less" suture mediated patent foramen ovale (PFO) closure system. Between June 2016 and October 2017, a prospective registry aimed at assessing the safety and efficacy of the NobleStitch EL (HeartStitch, Fountain Valley, CA) suture-based PFO closure system was carried out at 12 sites in Italy. Among 200 consecutive evaluated patients, 192 were considered suitable for suture-mediated PFO closure (44±13 years, 114 women). Suture of the septum with the NobleStitch EL system was carried out successfully in 186 (96%) patients. Median fluoroscopy time was 16.1 (13.0-22.5) minutes and contrast volume 200 (150-270) ml. At 206±130 days follow-up, microbubbles transthoracic echocardiography with Valsalva maneuver revealed no RLS (grade 0) in 139 (75%) patients and RLS grade ≤1 in 166 (89%) patients. Significant RLS was present in 20 (11%) patients (grade 2 and 3 in 11 and 9 patients, respectively). There were no device-related complications. The early results of this first Italian Registry indicates that the suture mediated "deviceless" closure of PFO is feasible in the majority of septal anatomies, provides an effective closure of PFO comparable to traditional devices with an excellent safety profile at medium term follow-up.
Zhai, Min; Zhang, Yong-An; Wang, Zhen-Yi; Sun, Jian-Hua; Wen, Jie; Zhang, Qi; Li, Jin-De; Wu, Yi-Zheng; Zhou, Feng; Xu, Hui-Lei
2016-01-01
Background. We aimed to evaluate the effectiveness of a suture-fixation mucopexy procedure by comparing with Doppler-guided hemorrhoidal artery ligation (DGHAL) in the management of patients with grade III hemorrhoids. Methods. This was a randomized controlled trial. One hundred patients with grade III hemorrhoids were randomly assigned to receive suture-fixation mucopexy (n = 50) or DGHAL (n = 50). Outcome assessments were performed at 2 weeks, 12 months, and 24 months. Assessments included resolution of clinical symptoms, postoperative complications, duration of hospitalization, and total costs. Results. At 2 weeks, one (2%) patient in suture-fixation group and four (8%) patients in DGHAL group had persistent prolapsing hemorrhoids. Postoperative bleeding was observed in two patients (4%) in suture-fixation group and one patient in DGHAL group. There was no significant difference in short-term recurrence between groups. Postoperative complications and duration of hospitalization were comparable between the two groups. Rates of recurrence of prolapse or bleeding at 12 months did not differ between groups. However, recurrence of prolapse at 24 months was significantly more common in DGHAL group (19.0% versus 2.3%, p = 0.030). Conclusions. Compared with DGHAL, the suture-fixation mucopexy technique had comparable short-term outcomes and favorable long-term outcomes. PMID:27066071
Chandramohan, S M; Gajbhiye, Raj Narenda; Agwarwal, Anil; Creedon, Erin; Schwiers, Michael L; Waggoner, Jason R; Tatla, Daljit
2013-08-01
Although stapling is an alternative to hand-suturing in gastrointestinal surgery, recent trials specifically designed to evaluate differences between the two in surgery time, anastomosis time, and return to bowel activity are lacking. This trial compared the outcomes of the two in subjects undergoing open gastrointestinal surgery. Adult subjects undergoing emergency or elective surgery requiring a single gastric, small, or large bowel anastomosis were enrolled into this open-label, prospective, randomized, interventional, parallel, multicenter, controlled trial. Randomization was assigned in a 1:1 ratio between the hand-sutured group (n = 138) and the stapled group (n = 142). Anastomosis time, surgery time, and time to bowel activity were collected and compared as primary endpoints. A total of 280 subjects were enrolled from April 2009 to September 2010. Only the time of anastomosis was significantly different between the two arms: 17.6 ± 1.90 min (stapled) and 20.6 ± 1.90 min (hand-sutured). This difference was deemed not clinically or economically meaningful. Safety outcomes and other secondary endpoints were similar between the two arms. Mechanical stapling is faster than hand-suturing for the construction of gastrointestinal anastomoses. Apart from this, stapling and hand-suturing are similar with respect to the outcomes measured in this trial.
A Novel Technique of Posterolateral Suturing in Thoracoscopic Diaphragmatic Hernia Repair
Boo, Yoon Jung; Rohleder, Stephan; Muensterer, Oliver J.
2017-01-01
Background Closure of the posterolateral defect in some cases of congenital diaphragmatic hernia (CDH) can be difficult. Percutaneous transcostal suturing is often helpful to create a complete, watertight closure of the diaphragm. A challenge with the technique is passing the needle out the same tract that it entered so that no skin is caught when the knots are laid down into the subcutaneous tissue. This report describes a novel technique using a Tuohy needle to percutaneously suture the posterolateral defect during thoracoscopic repair of CDH. Case We report a case of a 6-week-old infant who presented with a CDH and ipsilateral intrathoracic kidney that was repaired using thoracoscopic approach. The posterolateral part of the defect was repaired by percutaneous transcostal suturing and extracorporeal knot tying. To assure correct placement of the sutures and knots, a Tuohy needle was used to guide the suture around the rib and out through the same subcutaneous tract. The total operative time was 145 minutes and there were no perioperative complications. The patient was followed up for 3 months, during which there was no recurrence. Conclusion Our percutaneous Tuohy technique for closure of the posterolateral part of CDH enables a secure, rapid, and tensionless repair. PMID:28804698
A Novel Technique of Posterolateral Suturing in Thoracoscopic Diaphragmatic Hernia Repair.
Boo, Yoon Jung; Rohleder, Stephan; Muensterer, Oliver J
2017-01-01
Background Closure of the posterolateral defect in some cases of congenital diaphragmatic hernia (CDH) can be difficult. Percutaneous transcostal suturing is often helpful to create a complete, watertight closure of the diaphragm. A challenge with the technique is passing the needle out the same tract that it entered so that no skin is caught when the knots are laid down into the subcutaneous tissue. This report describes a novel technique using a Tuohy needle to percutaneously suture the posterolateral defect during thoracoscopic repair of CDH. Case We report a case of a 6-week-old infant who presented with a CDH and ipsilateral intrathoracic kidney that was repaired using thoracoscopic approach. The posterolateral part of the defect was repaired by percutaneous transcostal suturing and extracorporeal knot tying. To assure correct placement of the sutures and knots, a Tuohy needle was used to guide the suture around the rib and out through the same subcutaneous tract. The total operative time was 145 minutes and there were no perioperative complications. The patient was followed up for 3 months, during which there was no recurrence. Conclusion Our percutaneous Tuohy technique for closure of the posterolateral part of CDH enables a secure, rapid, and tensionless repair.
Albumen Glue, New Material for Conjunctival Graft Surgery, an Animal Experiment
NASA Astrophysics Data System (ADS)
Kartiwa, A.; Miraprahesti, R.; Sovani, I.; Enus, S.; Boediono, A.
2017-02-01
Attach conjunctival graft commonly used are suture technique and fibrin glue. This study was to investigate albumen glue as an alternative to suture technique in attaching conjunctival graft in rabbits. Aim of this study was to compare the conjunctival wound healing between albumen glue and suture technique in rabbit eye as a model. There was an experimental animal study included 32 eyes (16 rabbits) in PT. Bio Farma (Persero) and Histology Laboratory, Faculty of Medicine, Padjadjaran University from March 2014 to July 2104. The study consisted of albumen glue group and suture technique group. The examination included the comparison of conjunctival graft attachment and histologic examination by microscopically was done to obtain the wound gap, then analyze by Mann-Whitney test. The results indicated that the graft attachment was significantly better-using albumen glue (grade 4) compared to suture (grade 2-3) on day-1 after surgery (p=0,000). The wound gap was smaller using albumen glue (0-0,33 μm versus 5,33-14 μm ; p=0,0005) on 10 minutes after surgery and 0 μm versus 0,33-4 μm ; p=0,0005 on day-7 after surgery. In conclusion, the graft attachment using albumen glue was better and the wound gap was smaller using albumen glue than suture technique.
Multifaceted spiral suture: A hemostatic technique in managing placenta praevia or accrete
Meng, Yifan; Wu, Peng; Deng, Dongrui; Wu, Jianli; Lin, Xingguang; Beejadhursing, Rajluxmee; Zha, Ying; Qiao, Fuyuan; Feng, Ling; Liu, Haiyi; Zeng, Wanjiang
2017-01-01
Abstract Patients with total placenta previa and past history of cesarean delivery often experience overwhelming hemorrhage during childbirth. In order to control intraoperative and postoperative bleeding, we propose a novel multifaceted spiral suture of the lower uterine segment which directly sutures the bleeding site. To evaluate the efficacy and safety of multifaceted spiral suture, a retrospective study was conducted using data from 33 patients with total placenta praevia and caesarean history. All participants underwent multifaceted spiral suture and no patient experienced uncontrollable bleeding or underwent hysterectomy. The average blood loss of all patients involved was 1327.3 ± 1244.1 mL. Five patients reported blood loss exceeding 3000 mL (15.15%), and the highest reached to 4000 mL. No complications such as fever, pyometra, synechiae, or uterine necrosis were observed. Three cases (3/33, 9.09%) reported hematuria in the first 3 days following surgery and spontaneous resolution were observed within 3 to 7 days following insertion of indwelling catheters. No complaints were received during 6-month follow-up visits. These findings suggest that multifaceted spiral suture is a practical, feasible, and promising technique in potentially minimizing postpartum bleeding and avoiding hysterectomy for patients with placenta praevia or accrete. PMID:29245338
Selective laser vaporization of polypropylene sutures and mesh
NASA Astrophysics Data System (ADS)
Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.
2012-02-01
Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.
Umbilical hernia following gastroschisis closure: a common event?
Tullie, L G C; Bough, G M; Shalaby, A; Kiely, E M; Curry, J I; Pierro, A; De Coppi, P; Cross, K M K
2016-08-01
To assess incidence and natural history of umbilical hernia following sutured and sutureless gastroschisis closure. With audit approval, we undertook a retrospective clinical record review of all gastroschisis closures in our institution (2007-2013). Patient demographics, gastroschisis closure method and umbilical hernia occurrence were recorded. Data, presented as median (range), underwent appropriate statistical analysis. Fifty-three patients were identified, gestation 36 weeks (31-38), birth weight 2.39 kg (1-3.52) and 23 (43 %) were male. Fourteen patients (26 %) underwent sutureless closure: 12 primary, 2 staged; and 39 (74 %) sutured closure: 19 primary, 20 staged. Sutured closure was interrupted sutures in 24 patients, 11 pursestring and 4 not specified. Fifty patients were followed-up over 53 months (10-101) and 22 (44 %) developed umbilical hernias. There was a significantly greater hernia incidence following sutureless closure (p = 0.0002). In sutured closure, pursestring technique had the highest hernia rate (64 %). Seven patients underwent operative hernia closure; three secondary to another procedure. Seven patients had their hernias resolve. One patient was lost to follow-up and seven remain under observation with no reported complications. There is a significant umbilical hernia incidence following sutureless and pursestring sutured gastroschisis closure. This has not led to complications and the majority have not undergone repair.
Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita
2016-01-01
To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.
Frequency of Dehiscence in Hand-Sutured and Stapled Intestinal Anastomoses in Dogs.
Duell, Jason R; Thieman Mankin, Kelley M; Rochat, Mark C; Regier, Penny J; Singh, Ameet; Luther, Jill K; Mison, Michael B; Leeman, Jessica J; Budke, Christine M
2016-01-01
To determine the frequency of dehiscence of hand-sutured and stapled intestinal anastomoses in the dog and compare the surgery duration for the methods of anastomosis. Historical cohort study. Two hundred fourteen client-owned dogs undergoing hand-sutured (n = 142) or stapled (n = 72) intestinal anastomoses. Medical records from 5 referral institutions were searched for dogs undergoing intestinal resection and anastomosis between March 2006 and February 2014. Demographic data, presence of septic peritonitis before surgery, surgical technique (hand-sutured or stapled), surgery duration, surgeon (resident versus faculty member), indication for surgical intervention, anatomic location of resection and anastomosis, and if dehiscence was noted postoperatively were retrieved. Estimated frequencies were summarized and presented as proportions and 95% confidence intervals (CI) and continuous outcomes as mean (95% CI). Comparisons were made across methods of anastomosis. Overall, 29/205 dogs (0.14, 95% CI 0.10-00.19) had dehiscence, including 21/134 dogs (0.16, 0.11-0.23) undergoing hand-sutured anastomosis and 8/71 dogs (0.11, 0.06-0.21) undergoing stapled anastomosis. There was no significant difference in the frequency of dehiscence across anastomosis methods (χ(2), P = .389). The mean (95% CI) surgery duration of 140 minutes (132-147) for hand- sutured anastomoses and 108 minutes (99-119) for stapled anastomoses was significantly different (t-test, P < .001). No significant difference in frequency of dehiscence was noted between hand- sutured and stapled anastomoses in dogs but surgery duration is significantly reduced by the use of staples for intestinal closure. © Copyright 2015 by The American College of Veterinary Surgeons.
Parus, K; Lisiński, P; Huber, J
2015-11-01
Proprioception makes a critical contribution to body balance. The objective of this study was to evaluate static postural control after anterior cruciate ligament (ACL) reconstruction combined with medial meniscus (MM) suture, comparatively to healthy controls. Body balance is adversely affected 2 months after ACL reconstruction combined with MM suture. Fifteen patients (12 males and 3 females) aged 20 to 35 years (mean, 26.4 ± 6.0 years) who underwent ACL reconstruction with MM suture were compared to 20 healthy, physically active controls (16 females and 4 males) aged 19 to 23 years (mean, 21.1 ± 1.8 years), most of whom were physiotherapy students. Mean age was not significantly different between the patients and controls. A balance platform was used to estimate static postural control parameters. Each participant performed four tests, two in normal bipedal stance and two in tandem stance; in each stance, one test was done with the eyes open and the other with the eyes closed. We analysed global scores on a standardised 100-point scale and mean centre of pressure (COP) displacement velocity in the sagittal and frontal planes. Body balance was impaired 2 months after ACL reconstruction with MM suture. Thus, the patients had lower global scores and higher mean COP velocities in both the coronal and sagittal planes. Proprioception is impaired after ACL reconstruction with MM suture. Lack of visual control significantly decreases the ability to maintain balance. A balance platform is a useful diagnostic tool for patients with ACL reconstruction and MM suture. Level II. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Biomechanical and Histologic Evaluation of LifeMesh™: A Novel Self-Fixating Mesh Adhesive.
Shahan, Charles P; Stoikes, Nathaniel N; Roan, Esra; Tatum, James; Webb, David L; Voeller, Guy R
2018-04-01
Mesh fixation with the use of adhesives results in an immediate and total surface area adhesion of the mesh, removing the need for penetrating fixation points. The purpose of this study was to evaluate LifeMesh™, a prototype mesh adhesive technology which coats polypropylene mesh. The strength of the interface between mesh and tissue, inflammatory responses, and histology were measured at varying time points in a swine model, and these results were compared with sutures. Twenty Mongrel swine underwent implantation of LifeMesh™ and one piece of bare polypropylene mesh secured with suture (control). One additional piece of either LifeMesh™ or control was used for histopathologic evaluation. The implants were retrieved at 3, 7, and 14 days. Only 3- and 7-day specimens underwent lap shear testing. On Day 3, LifeMesh™ samples showed considerably less contraction than sutured samples. The interfacial strength of Day 3 LifeMesh™ samples was similar to that of sutured samples. At seven days, LifeMesh™ samples continued to show significantly less contraction than sutured samples. The strength of fixation at seven days was greater in the control samples. The histologic findings were similar in LifeMesh™ and control samples. LifeMesh™ showed significantly less contraction than sutured samples at all measured time points. Although fixation strength was similar at three days, the interfacial strength of LifeMesh™ remained unchanged, whereas sutured controls increased by day 7. With histologic equivalence, considerably less contraction, and similar early fixation strength, LifeMesh™ is a viable mesh fixation technology.
Samsudin, Amir; Eames, Ian; Brocchini, Steve; Khaw, Peng Tee
2016-07-01
Intraocular pressure and aqueous humor flow direction determined by the scleral flap immediately after trabeculectomy are critical determinants of the surgical outcome. We used a large-scale model to objectively measure the influence of flap thickness and shape, and suture number and position on pressure difference across the flap and flow of fluid underneath it. The model exploits the principle of dynamic and geometric similarity, so while dimensions were up to 30× greater than actual, the flow had similar properties. Scleral flaps were represented by transparent 0.8- and 1.6-mm-thick silicone sheets on an acrylic plate. Dyed 98% glycerin, representing the aqueous humor was pumped between the sheet and plate, and the equilibrium pressure measured with a pressure transducer. Image analysis based on the principle of dye dilution was performed using MATLAB software. The pressure drop across the flap was larger with thinner flaps, due to reduced rigidity and resistance. Doubling the surface area of flaps and reducing the number of sutures from 5 to 3 or 2 also resulted in larger pressure drops. Flow direction was affected mainly by suture number and position, it was less toward the sutures and more toward the nearest free edge of the flap. Posterior flow of aqueous humor was promoted by placing sutures along the sides while leaving the posterior edge free. We demonstrate a new physical model which shows how changes in scleral flap thickness and shape, and suture number and position affect pressure and flow in a trabeculectomy.
Hakamada, Kenichi; Narumi, Shunji; Toyoki, Yoshikazu; Nara, Masaki; Ishido, Kenosuke; Miura, Takuya; Kubo, Norihito; Sasaki, Mutsuo
2008-01-01
AIM: To clarify the usefulness of a new method for performing a pancreaticojejunostomy by using a fast-absorbable suture material irradiated polyglactin 910, and a temporary stent tube for a narrow pancreatic duct with a soft pancreatic texture. METHODS: Among 63 consecutive patients with soft pancreas undergoing a pancreaticoduodenectomy from 2003 to 2006, 35 patients were treated with a new reconstructive method. Briefly, after the pancreatic transaction, a stent tube was inserted into the lumen of the pancreatic duct and ligated with it by a fast-absorbable suture. Another tip of the stent tube was introduced into the intestinal lumen at the jejunal limb, where a purse-string suture was made by another fast-absorbable suture to roughly fix the tube. The pancreaticojejunostomy was completed by ligating two fast-absorbable sutures to approximate the ductal end and the jejunal mucosa, and by adding a rough anastomosis between the pancreatic parenchyma and the seromuscular layer of the jejunum. The initial surgical results with this method were retrospectively compared with those of the 28 patients treated with conventional duct-to-mucosa anastomosis. RESULTS: The incidences of postoperative morbidity including pancreatic fistula were comparable between the two groups (new; 3%-17% vs conventional; 7%-14% according to the definitions). There was no mortality and re-admission. Late complications were also rarely seen. CONCLUSION: A pancreaticojejunostomy using an irradiated polyglactin 910 suture material and a temporary stent is easy to perform and is feasible even in cases with a narrow pancreatic duct and a normal soft pancreas. PMID:18286692
Liboni, A; Mari, C; Zamboni, P; Uzzau, A; Noce, L; Bucoliero, F; Mele, M; Masala, C
1989-01-01
Staplers have improved the results of esophageal surgery, in our experience and in others experience, as esophago-enteric anastomoses have become safer and faster than when manual suturing is used. Probably one of the last problems in the stapler technique, especially in the thoracic area, is the performance of on adequate esophageal purse-string suture: an improper performance of this suture can cause a dangerous leak of the anastomosis. So, many surgeons, to reduce the risk of esophageal dehiscence connected with the esophageal purse-string, use either purse-string devices or alternative methods such as a second handsewn purse-string, U stitches of the esophagus, etc. We think that the risk of improper anastomoses after esophageal resection can be reduced if the need for the esophageal purse-string can be eliminated. This work shows our personal technique for performing esophagoenterostomy, especially in the thoracic area, using the new CEEA stapler (Autosuture) without esophageal purse-string sutures. According to the modified procedure the stapler anvil and the mini rod are introduced in the esophagectomy and a 2-0 thread is knotted around the CEEA mini rod. Then the esophageal mutilated part is closed by a linear stapler keeping a syringe needle, which contains the thread, through the linear suture. Then, using the thread as a pulling system, the surgeon makes the needle and the tip of the mini rod slide out of the esophageal suture. Now the surgeon can reassemble the CEEA and perform the anastomosis. There are many clinical reports that cite no leaks following circular stapled anastomoses across linear stapled closures.
Ostrander, Roger V; McKinney, Bart I
2012-10-01
Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Gillen, Alex M; Munsterman, Amelia S; Hanson, R Reid
2016-11-01
To investigate the strength, size, and holding capacity of the self-locking forwarder knot compared to surgeon's and square knots using large gauge suture. In vitro mechanical study. Knotted suture. Forwarder, surgeon's, and square knots were tested on a universal testing machine under linear tension using 2 and 3 USP polyglactin 910 and 2 USP polydioxanone. Knot holding capacity (KHC) and mode of failure were recorded and relative knot security (RKS) was calculated as a percentage of KHC. Knot volume and weight were assessed by digital micrometer and balance, respectively. ANOVA and post hoc testing were used tocompare strength between number of throws, suture, suture size, and knot type. P<.05 was considered significant. Forwarder knots had a higher KHC and RKS than surgeon's or square knots for all suture types and number of throws. No forwarder knots unraveled, but a proportion of square and surgeon's knots with <6 throws did unravel. Forwarder knots had a smaller volume and weight than surgeon's and square knots with equal number of throws. The forwarder knot of 4 throws using 3 USP polyglactin 910 had the highest KHC, RKS, and the smallest size and weight. Forwarder knots may be an alternative for commencing continuous patterns in large gauge suture, without sacrificing knot integrity, but further in vivo and ex vivo testing is required to assess the effects of this sliding knot on tissue perfusion before clinical application. © Copyright 2016 by The American College of Veterinary Surgeons.
Silk suture reaction in thyroid surgery
Soylu, Selen; Teksoz, Serkan; Ozcan, Murat; Bukey, Yusuf
2017-01-01
Silk suture reaction (i.e., a benign granulomatous inflammatory foreign body reaction) is a rare complication of thyroid surgery. Here, two cases of post-thyroidectomy suture reaction are presented. Both of the patients were female, one is 48 and the other is 34 years old. The patients were presented with neck swelling and leakage of serous fluid from the Kocher’s incision. Both patients had normal free T4, free T3, and TSH values. The 48-year-old female patient had a right subtotal and left near-total thyroidectomy 6 years ago and the other had bilateral total thyroidectomy 6 years ago. In the physical examination a mobile, painless, red, swelling was palpated in front of neck. In the ultrasound of both patients, a heterogeneous nodule with hypoechoic rim was seen, however, in scintigraphy no radiopharmaceutical involvement was observed in thyroid region. Due to suspicion of thyroid malignancy, a fine needle aspiration biopsy was performed and foreign body reaction was revealed cytologically. A suture reaction can vary from an erythematous swelling to chronic granulomatous reaction. The time interval between the operation and formation of suture reaction was 6 years in both of the cases thus these patients were considered as chronic patients. Foreign body reaction diagnosis was confirmed with fine needle aspiration biopsy. It is important to diagnose these chronic inflammation cases since these cases can mimic recurrence in thyroid malignancies. A post-thyroidectomy suture reaction is diagnosed cytologically with fine needle aspiration biopsy and by surgical removal of suture, this chronic inflammatory reaction can be cured. PMID:29142853
The Cartilage Warp Prevention Suture.
Guyuron, Bahman; Wang, Derek Z; Kurlander, David E
2018-06-01
Costal cartilage graft warping can challenge rhinoplasty surgeons and compromise outcomes. We propose a technique, the "warp control suture," for eliminating cartilage warp and examine outcomes in a pilot group. The warp control suture is performed in the following manner: Harvested cartilage is cut to the desired shape and immersed in saline to induce warping. A 4-0 or 5-0 PDS suture, depending the thickness of the cartilage, is passed from convex to concave then concave to convex side several times about 5-6 mm apart, finally tying the suture on the convex side with sufficient tension to straighten the cartilage. First an ex vivo experiment was performed in 10 specimens from 10 different patients. Excess cartilage was sutured and returned to saline for a minimum of 15 min and then assessed for warping compared to cartilage cut in the identical shape also soaked in saline. Then, charts of nine subsequent patients who received the warp control suture on 16 cartilage grafts by the senior author (BG) were retrospectively reviewed. Inclusion of study subjects required at least 6 months of follow-up with standard rhinoplasty photographs. Postoperative complications and evidence of warping were recorded. In the ex vivo experiment, none of the 10 segments demonstrated warping after replacement in saline, whereas all the matching segments demonstrated significant additional warping. Clinically, no postoperative warping was observed in any of the nine patients at least 6 months postoperatively. One case of minor infection was observed in an area away from the graft and treated with antibiotics. No warping or other complications were noted. The warp control suture technique presented here effectively straightens warped cartilage graft and prevents additional warping. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Estimating incision healing rate for surgically implanted acoustic transmitters from recaptured fish
Schoonyan, Abby; Kraus, Richard T.; Faust, Matthew D.; Vandergoot, Christopher; Cooke, Steven J.; Cook, H. Andrew; Hayden, Todd A.; Krueger, Charles C.
2017-01-01
Background Intracoelomic implantation of electronic tags has become a common method in fishery research, but rarely are fish examined by scientists after release to understand the extent that surgical incisions have healed. Walleye (Sander vitreus) are a valuable, highly exploited fishery resource in the Laurentian Great Lakes. Here, fishery capture of walleye with internal acoustic transmitters combined with a high reward program provided multiple opportunities to examine photographs and quantify the status of surgical incisions. Walleye (n = 926) from reef and river spawning populations in Lake Erie and Lake Huron were implanted with acoustic transmitters during spring spawning events from 2011 to 2016. Incisions were closed with polydioxanone monofilament using two to three interrupted sutures. Out of 276 recaptured fish, 60 incision sites were clearly visible in photographs, and these were scored by two independent readers for incision closure, inflammation, and the presence of sutures.Results While incision sites were completely closed by 61 days post-release (95% CI 44–94), sutures remained for up to 866 days. Sutures were expelled serially during a protracted period, and the probability of observing at least one suture in a recaptured fish declined below 50% after 673 days (95% CI 442–1016). Inflammation at the incision increased during the first 71 days and then declined monotonically, remaining detectable at low levels.Conclusion Our results emphasized that sutures remained in free-ranging fish past the time when they were beneficial for incision healing. Most dissolvable sutures have been designed for use in endotherms where the body temperature and internal milieu differ dramatically from the conditions experienced by fishes in temperate climates. Identification of new suture materials for fish that facilitate healing while absorbing or dissolving in a reasonable period (e.g., a few weeks to three months) in colder temperatures (e.g., <12 °C) would be beneficial to mitigate potential adverse impacts from inflammation at the incision.
Biomechanical evaluation of various suture configurations in side-to-side tenorrhaphy.
Wagner, Emilio; Ortiz, Cristian; Wagner, Pablo; Guzman, Rodrigo; Ahumada, Ximena; Maffulli, Nicola
2014-02-05
Side-to-side tenorrhaphy is increasingly used, but its mechanical performance has not been studied. Two porcine flexor digitorum tendon segments of equal length (8 cm) and thickness (1 cm) were placed side by side. Eight tenorrhaphies (involving sixteen tendons) were performed with each of four suture techniques (running locked, simple eight, vertical mattress, and pulley suture). The resulting constructs underwent cyclic loading on a tensile testing machine, followed by monotonically increasing tensile load if failure during cyclic loading did not occur. Clamps secured the tendons on each side of the repair, and specimens were mounted vertically. Cyclic loading varied between 15 N and 35 N, with a distension rate of 1 mm/sec. Cyclic loading strength was determined by applying a force of 70 N. The cause of failure and tendon distension during loading were recorded. All failures occurred in the monotonic loading phase and resulted from tendon stripping. No suture or knot failure was observed. The mean loads resisted by the configurations ranged from 138 to 398 N. The mean load to failure, maximum load resisted prior to 1 cm of distension, and load resisted at 1 cm of distension were significantly lower for the vertical mattress suture group than for any of the other three groups (p < 0.031). All four groups sustained loads well above the physiologic loads expected to occur in tendons in the foot and ankle (e.g., in tendon transfer for tibialis posterior tendon insufficiency). None of the four side-to-side configurations distended appreciably during the cyclic loading phase. The vertical mattress suture configuration appeared to be weaker than the other configurations. For surgeons who advocate immediate loading or motion of a side-to-side tendon repair, a pulley, running locked, or simple eight suture technique appears to provide a larger safety margin compared with a vertical mattress suture technique.
The Misgav Ladach method--a step forward in operative technique in obstetrics.
Fatusić, Zlatan; Kurjak, Asim; Jasarević, Edin; Hafner, Tomislav
2003-01-01
To investigate the advantage of performing cesarean section using the Misgav-Ladach method and to justify its use in everyday practice. In a prospective study we analyzed over a two year period (2000-01) cesarean sections carried out using the Misgav-Ladach method at our clinic. We compared both 550 cases of Misgav-Ladach (ML) and 100 cases of Pfannenstiel (PH) cesarean section. In the group that had undergone the Misgav-Ladach method we sutured the uterus in one layer and left the peritoneum non-sutured, and in the group who had undergone Pfennenstiel we sutured the uterus in two layers and also sutured the visceral and parietal peritoneum. In every case we analyzed: maternal age, gestational age, duration of operation, consumption of suture material, duration of hospitalization, and surgical complications. Incidence of postoperative febrile morbidity was 5.45%, in the Misgav-Ladach group compared with 13.2% in the Pfannenstiel group (p < 0.05). Local infection of the wound in the Misgav-Ladach group was found in 4.54% and in the Pfannenstiel group in 9% (p < 0.05). Mean time of extraction of the newborn in the Misgav-Ladach group was 1.25 minutes, and in the Pfannenstiel group 4.10 minutes (P < 0.05). Mean duration of operation in the Misgav-Ladach group was 10.98 min, and in the Pfannenstiel group 25 min (p < 0.05). Mean duration of hospitalization in the Misgav-Ladach group was 4.75 days, and in the Pfannenstiel group 6.32 days (p > 0.05). Mean consumption of suture material in the group Misgav-Ladach was 3.10 sutures per operation, and in the Pfannenstiel group was 9.5 sutures. Our study shows that the Misgav-Ladach method of cesarean section enables fast recovery and shorter hospitalization, and reduces the length of the operation, the incidence of surgical complication and the consumption of surgical materials.
[Treatment of calcaneal avulsion fractures with twinfix suture anchors fixation].
Zhao, Bin-xiu; Wang, Kun-zheng; Wang, Chun-sheng; Xie, Yue; Dai, Zhi-tang; Liu, Gang; Liu, Wei-dong
2011-06-01
For the calcaneal avulsion fracture, the current method is more commonly used screws or Kirschner wire to fix fracture fragment. This article intended to explore the feasibility and clinical efficacy for the treatment of avulsion fractures with TwinFix suture anchors. From July 2007 to November 2010, 21 patients were reviewed, including 15 males and 6 females, ranging in age from 49 to 65 years,with a mean of 58.7 years. Twelve patients had nodules in the right heel and 9 patients had nodules in the left heel. All the patients had closed fractures. The typical preoperative symptoms of the patients included pain in the upper heel and weak in heel lift. Body examination results: palpable sense of bone rubbing in the back of the heel, and swelling in the heel. Surgery treatment with TwinFix suture anchors performed as follows : to fix TwinFix suture anchors into the calcaneal body, then to drill the fracture block, to make the double strand suture through the fracture holes, to knot the suture eachother to fix the block, and to use stitch to fix the remaining suture in the Achilles tendon in order to improve the block fixation. The criteria of the AOFAS Foot and Ankle Surgery by the United States Association of ankle-rear foot functional recovery was used to evaluate the Achilles tendon. Total average score was (95.5 +/- 3.12) points, including pain items of(38.5 +/- 2.18) points,the average score of functional items of (49.5 +/- 3.09) points,and power lines of 10 points in all patients. Twenty-one patients got an excellent result, 16 good and 5 poor. The methods of treatment for the calcaneal avulsion fractures with TwinFix suture anchors is a simple operation, and have excellent clinical effect, which is worthy of promotion.
Buchhorn, G. H.; Gilbert, F.; Spahn, G.; Schultz, W.; Klinger, H.-M.
2010-01-01
Aim This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. Method In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond® coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi® with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond® coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi® with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason–Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Results Group 4 showed lowest load-to-failure result with 155.7 ± 31.1 N compared to group 1 (293.4 ± 16.1 N) and group 2 (397.7 ± 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 ± 7.3 N/mm) and lowest in group 4 (84.4 ± 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). Conclusions A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used. PMID:20049605
Feucht, Matthias J; Grande, Eduardo; Brunhuber, Johannes; Burgkart, Rainer; Imhoff, Andreas B; Braun, Sepp
2013-12-01
A tear of the posterior medial meniscus root (PMMR) is increasingly recognized as a serious knee joint injury. Several suture techniques for arthroscopic transtibial pull-out repair have been described; however, only limited data about the biomechanical properties of these techniques are currently available. There are significant differences between the tested suture techniques, with more complex suture configurations providing superior biomechanical properties. Controlled laboratory study. A total of 40 porcine medial menisci were randomly assigned to 1 of 4 groups (10 specimens each) according to suture technique: two simple stitches (TSS), horizontal mattress suture (HMS), modified Mason-Allen suture (MMA), and two modified loop stitches (TLS). Meniscus-suture constructs were subjected to cyclic loading followed by load-to-failure testing in a servohydraulic material testing machine. During cyclic loading, the HMS and TLS groups showed a significantly higher displacement after 100, 500, and 1000 cycles compared with the TSS and MMA groups. After 1000 cycles, the highest displacement was found for the TLS group, with significant differences compared with all other groups. During load-to-failure testing, the highest maximum load and yield load were observed for the MMA group, with statistically significant differences compared with the TSS and TLS groups. With regard to stiffness, the TSS and MMA groups showed significantly higher values compared with the HMS and TLS groups. The MMA technique provided the best biomechanical properties with regard to cyclic loading and load-to-failure testing. The TSS technique seems to be a valuable alternative. Both the HMS and TLS techniques have the disadvantage of lower stiffness and higher displacement during cyclic loading. Using a MMA technique may improve healing rates and avoid progressive extrusion of the medial meniscus after transtibial pull-out repair of PMMR tears. The TSS technique may be used as an alternative that is easier to perform, but a more careful rehabilitation program is possibly necessary to avoid early failure.
White, Jeremy B; Barraja, Mathieu; Mengesha, Tewodros; Bose, Sumit; Ashktorab, Samaneh; Bahn, Ryan; Vallance, Ryan; Lindsey, William H
2008-12-01
Manipulation and suspension of the superficial musculoaponeurotic system (SMAS) is performed by 74% of rhytidectomy surgeons. Multiple variations in suture techniques are employed in this task, but they have never been evaluated for differences in their ability to withstand stress. To compare the biomechanical properties of two different suture techniques that are used in SMAS plications during rhytidectomy: a double-layered running locking (DRL) stitch and multiple horizontal mattress stitches. Fourteen horizontal mattress plications, in rows of six sutures, and comparable lengths of 16 DRL stitch plications of pig skin samples, were stressed using a tensometer with grip displacement increasing at a constant rate of 0.5 cm/Min. The required force to cause plication failure was recorded for each sample at three suture break points. There was no significant difference between the two groups in the force required to cause the initial suture failure. Unlike the horizontal mattress plication, an initial break seemed to cause minimal to no distortion of the DRL tissue plication. When results were normalized by the initial break forces to account for small variations in tissue properties, the force ratio required to cause a second suture break was significantly larger in the DRL group than in the horizontal mattress technique. This is evidenced by the average second to first break force ratios of 1.62 vs. 1.13 for the DRL and horizontal mattress stitches, respectively, with a P-value of .60. The mean ratios of third to first break forces for the DRL and horizontal mattress groups were 2.08 and 0.91, respectively, with a P-value of .08. The DRL stitch requires more force than the horizontal mattress stitch to cause significant failure of tissue plication. This technique may enable plastic surgeons to avoid early revision rhytidectomy due to suture failure, and to create a long-lasting, youthful cosmetic result.
Transected sciatic nerve repair by diode laser protein soldering.
Fekrazad, Reza; Mortezai, Omid; Pedram, MirSepehr; Kalhori, Katayoun Am; Joharchi, Khojasteh; Mansoori, Korosh; Ebrahimi, Roja; Mashhadiabbas, Fatemeh
2017-08-01
Despite advances in microsurgical techniques, repair of peripheral nerve injuries (PNI) is still a major challenge in regenerative medicine. The standard treatment for PNI includes suturing and anasthomosis of the transected nerve. The objective of this study was to compare neurorraphy (nerve repair) using standard suturingto diode laser protein soldering on the functional recovery of transected sciatic nerves. Thirty adult male Fischer-344 Wistar rats were randomly assigned to 3 groups: 1. The control group, no repair, 2. the standard of care suture group, and 3. The laser/protein solder group. For all three groups, the sciatic nerve was transected and the repair was done immediately. For the suture repair group, 10.0 prolene suture was used and for the laser/protein solder group a diode laser (500mW output power) in combination with bovine serum albumen and indocyanine green dye was used. Behavioral assessment by sciatic functional index was done on all rats biweekly. At 12weeks post-surgery, EMG recordings were done on all the rats and the rats were euthanized for histological evaluation of the sciatic nerves. The one-way ANOVA test was used for statistical analysis. The average time required to perform the surgery was significantly shorter for the laser-assisted nerve repair group compared to the suture group. The EMG evaluation revealed no difference between the two groups. Based on the sciatic function index the laser group was significantly better than the suture group after 12weeks (p<0.05). Histopathologic evaluation indicated that the epineurium recovery was better in the laser group (p<0.05). There was no difference in the inflammation between the suture and laser groups. Based on this evidence, laser/protein nerve soldering is a more efficient and efficacious method for repair of nerve injury compared to neurorraphy using standard suturing methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Ugur, Murat; Byrne, John G; Bavaria, Joseph E; Cheung, Anson; Petracek, Michael; Groh, Mark A; Suri, Rakesh M; Borger, Michael A; Schaff, Hartzell V
2014-10-01
The study objective was to evaluate whether aortic valve replacement with the Trifecta valve (St Jude Medical Inc, St Paul, Minn) using simple sutures produces better hemodynamic performance than valve replacement with noneverting pledget-reinforced sutures. We analyzed prospectively acquired 1-year hemodynamic data of patients with small aortic annulus sizes who were enrolled in a multicenter trial of the Trifecta aortic valve bioprosthesis and underwent aortic valve replacement with a 19-mm or 21-mm bioprosthesis between August 2007 and November 2009. We compared preoperative clinical information and 1-year postoperative hemodynamic data for noneverting pledget-reinforced sutures (group 1) versus everting mattress sutures or simple sutures (group 2). A total of 346 patients underwent aortic valve replacement: 269 in group 1 and 77 in group 2. Preoperative demographic characteristics for the 2 groups were similar. For groups 1 and 2, the mean gradient was 10.4±4.7 mm Hg and 11.1±4.4 mm Hg for 19-mm valves, respectively, and 8.4±3.5 mm Hg and 8.8±3.6 mm Hg for 21-mm valves, respectively; the effective orifice area was 1.40 cm2 and 1.25 cm2 for 19-mm valves, respectively, and 1.57 cm2 and 1.50 cm2 for 21-mm valves, respectively. The rate of severe prosthesis-patient mismatch (indexed effective orifice area≤0.65 cm2/m2) was 18.6% (n=11) and 25% (n=6) for 19-mm valves, respectively, and 10.9% (n=20) and 16.3% (n=8) for 21-mm valves, respectively. The suture method did not affect hemodynamic performance of supra-annular bioprostheses in patients with small aortic annulus sizes. Choice of suture technique should be determined by surgeon experience and local anatomic features. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
A new method for hepatic resection and hemostasis: absorbable plaque and suture.
Ozer, M Tahir; Eryilmaz, Mehmet; Coskun, Kagan; Demirbas, Sezai; Uzar, A Ihsan; Kozak, Orhan
2010-04-01
Blunt and penetrating hepatic injuries are conditions that are frequently encountered in emergency surgeries, and they involve high mortality morbidity. In the handling of such injuries, methods ranging from the application of simple cauterization and suturing for hemostasis to hepatic lobectomies, which might involve the removal of the greater part of the organ, have been defined. Due to the organ's fragility and susceptibility to bleeding, elective hepatic resections necessitate both surgical experience and technological equipment. Therefore, the demand still exists for an affordable and easy-to-use-method that could be applied by all centers. To meet this demand, we have developed a method of hemorrhage control via sutures supported by absorbable plaques that provide effective compression and prevent the suture from cutting the tissue during the application of the sutures in the treatment of such fragile organs as the liver. In our method, we have achieved hemostasis by bilaterally compressing the tissue through strong ties after placing, on the part of the tissue on which the sutures are applied, absorbable and flexible plaques that prevent the suture from cutting the tissue during the application of a polyglactin suture to the solid organ. To prevent dislocation of the plaques, we have fastened the sutures by reeving them through the holes made in the plaques. We have demonstrated the success and the practicality of our method by applying it on four pigs; we experimentally inflicted hepatic injuries on two pigs, and we performed resection on the other two pigs. The hepatic hemorrhages we developed in both of the animals were successfully restrained by the use of our method. On the other hand, two resections were performed on the right and left lobes of the other two animals. There were no hemorrhages during the surgery, and the procedure took 45 minutes in total. No postoperative complications occurred. While the liver function test values were high on the seventh day, due to the operation, they were observed to be normal on the thirtieth day. After the laparotomies, performed six months later, we observed that the plaques as well as the sutures were absorbed and that the injured tissues were completely healed. Additionally, it was observed during the pathological examination that the tissues beneath the area of application were healed through fibrosis and that the liver had no other pathologies. In conclusion, we believe that the method can be safely used in hepatic resections or traumatic hemorrhages in the proper locations.
Lorbach, Olaf; Kieb, Matthias; Raber, Florian; Busch, Lüder C; Kohn, Dieter; Pape, Dietrich
2012-02-01
To compare the biomechanical properties and footprint coverage of a single-row (SR) repair using a modified suture configuration versus a double-row (DR) suture-bridge repair in small to medium and medium to large rotator cuff tears. We created 25- and 35-mm artificial defects in the rotator cuff of 24 human cadaveric shoulders. The reconstructions were performed as either an SR repair with triple-loaded suture anchors (2 to 3 anchors) and a modified suture configuration or a modified suture-bridge DR repair (4 to 6 anchors). Reconstructions were cyclically loaded from 10 to 60 N. The load was increased stepwise up to 100, 180, and 250 N. Cyclic displacement and load to failure were determined. Furthermore, footprint widths were quantified. In the 25-mm rupture, ultimate load to failure was 533 ± 107 N for the SR repair and 681 ± 250 N for the DR technique (P ≥ .21). In the 35-mm tear, ultimate load to failure was 792 ± 122 N for the SR reconstruction and 891 ± 174 N for the DR reconstruction (P ≥ .28). There were no statistically significant differences for both tested rupture sizes. Cyclic displacement showed no significant differences between the tested configurations at 60 N (P = .563), 100 N (P = .171), 180 N (P = .211), and 250 N (P = .478) for the 25-mm tear. For the 35-mm tear, cyclic displacement showed significantly lower gap formation for the SR reconstruction at 180 N (P = .037) and 250 N (P = .020). No significant differences were found at 60 N (P = .296) and 100 N (P = .077). A significantly greater footprint width (P = .028) was seen for the DR repair (16.2 mm) compared with the SR repair (13.8 mm). However, both reconstructions were able to achieve complete footprint coverage compared with the initial footprint. The tested SR repair using a modified suture configuration was similar in load to failure and cyclic displacement to the DR suture-bridge technique independent of the tested initial sizes of the rupture. The tested DR repair consistently restored a larger footprint than the SR method. However, both constructs achieved complete footprint coverage. SR repairs with modified suture configurations might combine the biomechanical advantages and increased footprint coverage that are described for DR repairs without increasing the overall costs of the reconstruction. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Shaukat, Noureen; Jaleel, Farhat; Jawaid, Masood; Zulfiqar, Imrana
2018-01-01
Chronic pain occurs in 20-30% of patients after hernia surgery. As a consequence of this chronic pain, almost one third of patients have limitations in daily activities. Frequency and severity of this pain varies with different techniques of hernia repair. The objective of this study was to compare polypropylene suture and skin staples for securing mesh in uncomplicated ventral hernioplasty in terms of acute and chronic postoperative pain and to compare the time taken for mesh fixation between polypropylene sutures and skin stapler in ventral hernioplasty. This study was conducted in Surgery Department of Dow University Hospital, Dow University of Health Sciences, Ojha Campus and included 53 patients from Jan 2015 to Dec 2016, after taking informed consent. All patients were operated under general anesthesia by the same surgical team. Patients were randomized into two groups; in one group mesh fixed with 2/0 polypropylene suture while in other group mesh stapler was used. Time taken to apply mesh was noted in minutes from laying the mesh over anterior rectus sheath to completion of fixation by either method. The severity of post-operative pain was measured with VAS (1-10) after one week, one month and after one year after surgery. Data was analysed using SPSS version 17. Patient characteristics and operative outcome were similar in the two groups and statistically non-significant in both. Early postoperative pain was more after suture fixation but it was not statistically significant. Mean ± SD pain score was after one week 3.47±2.7 after sutures while 2.91±1.88 after stapler. After four weeks, 0.40±0.49 after suture while 0.35±0.48 after stapler fixation. In both study groups 30-34% of the patients felt some pain in follow-up after one year. Severity of pain was 0.60±0.62 after suture while 1.65±1.94 after stapler fixation which is statistically significant as well (p<0.007). Mean operative time was 15.33±6.33 minutes for suture fixation while 1.56±0.41 minutes for fixation by staples, p-value < 0.001. The method of fixation does not appear to cause significant difference in early post-operative pain but chronic pain is more after stapler fixation of mesh. However, operative time was reduced significantly in staple fixation group as compared to suture fixation group.
Zhang, Tao; Wan, Chun-you; Ma, Bao-tong; Xu, Wei-guo; Mei, Xiao-long; Jia, Peng; Liu, Lei
2016-05-01
To compare clinical outcomes between two suturing methods using non absorbable materials through drilling the bone and suturing anchors for the treatment of complete rupture of the deltoid ligament. From January 2009 to January 2013, 58 hospitalized patients with ankle fracture combined with complete rupture of the deltoid ligament were treated with suturing using non absorbable materials through drilling the bone or suturing anchors. There were 29 patients who received suturing treatments using non absorbable materials through drilling the bone (Group A), including 18 males and 11 females, with an average age of (39.76 +/- 11.81) years old. According to the Lauge-Hansen classification, 12 patients had supination external rotation (SER) injuries with IV degree, 5 patients had pronation external rotation (PER) injuries with III degree, 10 patients had PER injuries with IV degrss, and 2 patients had pronation abduction injuries with III degree. There were 29 patients who received treatments with suturing using anchors (Group B), including 14 males and 15 females, with an average age of (41.79 +/- 13.28) years old. According to the Lauge-Hansen classification,9 patients had SER injuries with IV degree, 6 patients had PER injuries with III degree,13 patients had PER injuries with IV degree, and 1 patient had pronation abduction injuries with III degree. All the patients were treated with open reduction and internal fixation, as well as reconstruction of deltoid ligaments to restore the stability of the medial ankle structures. The clinical examination, imaging evaluation, American society for ankle surgery (AOFAS) ankle-hindfoot score and visual analogue scale (VAS) were used to evaluate the clinical results after operation, and the results of the two groups were compared and analyzed statistically. The follow-up duration of the 58 patients ranged from 23 to 40 months,with an average of 27.3 months. All the patients had fracture union, and the mean healing time was 12.3 weeks (ranged, 10 to 17 weeks). There were no incision complications and ankle instability. There were no significant differences between two groups in AOFAS (P=0.666) and the VAS (P=0.905). Treatments of complete rupture of the deltiod ligaments with the two suturing methods get similar good clinical effects, but the suturing using non absorbable materials through drilling the bone has several advantages such as reducing the financial burden of patients, saving social medical resources and avoiding the shortcoming in difficult removal of anchor suture.
Strength of bone tunnel versus suture anchor and push-lock construct in Broström repair.
Giza, Eric; Nathe, Ryan; Nathe, Tyler; Anderson, Matthew; Campanelli, Valentina
2012-06-01
Operative treatment of mechanical ankle instability is indicated for patients who have had multiple sprains and have continued episodes of instability despite bracing and rehabilitation. Anatomic reconstruction has been shown to have improved outcomes and return to sport as compared with nonanatomic reconstruction. The use of 2 suture anchors and a push-lock anchor is equal to 2 bone tunnels in strength to failure for anatomic Broström repair. Controlled laboratory study. In 7 matched pairs of human cadaver ankles, the calcaneofibular ligament (CFL) and anterior talofibular ligament (ATFL) were incised from their origin on the fibula. A No. 2 Fiberwire suture was placed into the CFL and a separate suture into the ATFL in a running Krackow fashion with a total of 4 locking loops. In 1 ankle of the matched pair, the ligaments were repaired to their anatomic insertion with bone tunnels. In the other, 2 suture anchors were used to reattach the ligaments to their anatomic origins, and a push-lock was used proximally to reinforce these suture anchors. The ligaments were cyclically loaded 20 times and then tested to failure. Torque to failure, degrees to failure, and stiffness were measured. The authors performed a matched pair analysis. An a priori power analysis of 0.8 demonstrated 6 pairs were needed to show a difference of 30% with a 15% standard error at a significance level of .05. There was no difference in the degrees to failure, torque to failure, and stiffness. A post hoc power analysis of torque to failure showed a power of .89 with 7 samples. Power for initial stiffness was .97 with 7 samples. Eleven of 14 specimens failed at either the suture anchor or the bone tunnel. There is no statistical difference in strength or stiffness for a suture anchor and push-lock construct as compared with a bone tunnel construct for an anatomic repair of the lateral ligaments of the ankle. The use of suture anchors in lateral ligament stabilization allows for a smaller incision, less surgical dissection, and improved surgical efficiency. It is up to the discretion of the performing surgeon based on preference, ease of use, operative time, and cost profile to choose either of these constructs for anatomic repair of the lateral ligaments of the ankle. The suture repair at the ligament was significantly strong enough such that the majority of ankles failed at the bone interface.